39
Information Technology Software Quality Assurance FLUOR – B & W Portsmouth, LLC On-Site Waste Disposal Facility COMPUTER-AIDED DESIGN AND DRAFTING (CADD) MANUAL AND DRAWING STANDARDS January , 2014 Table of Contents

FLUOR – B & W Portsmouth, LLC On-Site Waste Disposal Facilityfbportsmouth.com/docs/Solicitations/ILTS-2014/1 - FBP OSWDF CADD... · FLUOR – B & W Portsmouth, LLC On-Site Waste

Embed Size (px)

Citation preview

Page 1: FLUOR – B & W Portsmouth, LLC On-Site Waste Disposal Facilityfbportsmouth.com/docs/Solicitations/ILTS-2014/1 - FBP OSWDF CADD... · FLUOR – B & W Portsmouth, LLC On-Site Waste

Information Technology Software Quality Assurance

FLUOR – B & W Portsmouth, LLC

On-Site Waste Disposal Facility

COMPUTER-AIDED

DESIGN AND DRAFTING

(CADD) MANUAL

AND DRAWING STANDARDSJanuary , 2014

Table of Contents

Page 2: FLUOR – B & W Portsmouth, LLC On-Site Waste Disposal Facilityfbportsmouth.com/docs/Solicitations/ILTS-2014/1 - FBP OSWDF CADD... · FLUOR – B & W Portsmouth, LLC On-Site Waste

Page 2 of 397/24/2014

_______________________________________________________________MicroStation CADD Standards and Procedures

1.0 Scope ……………………………………………………………...…………………………………….4

2.0 General Setup and Configuration…….……………………………………………………………… 4

2.1 Coordinate System…….………………………………………………………………………………………..4

2.2 Units…….……………………………………………………………………………………………………………….4

2.3 Design Software…………………………………………………………………………………………………..4

2.4 Data Access………………………………………………………………………………………………………….4

2.5 Microstation Configuration…………………………………………………………………………………..5

2.6 Configuration Variables………………………………………………………………………………………..5

3.0 Drawing Standards……………………………………………………………………………………………….5

3.1 Drawing Sizes……………………………………………………………………………………………………….5

3.2 Drawing Borders…………………………………………………………………………………………………..5

3.3 Drawing Numbering and File Naming Standards………………………………………………..7

3.4 Drawing Revisions ……………………………………………………………………………………………….7

4.0 General Drafting Standards…………………………………………………………………………………9

4.1 CADD File Types…………………………………………………………………………………………………..9

4.2 Level Conventions………………………………………………………………………………………………..12

4.3 Pen Tables…………………………………………………………………………………………………………….13

4.4 Line Weights…………………………………………………………………………………………………………13

4.5 Line Styles…………………………………………………………………………………………………………….13

4.6 Half-Tone Linewok………………………………………………………………………………………………..13

4.7 Plot Data……………………………………………………………………………………………………………….13

4.8 Seed Files……………………………………………………………………………………………………………..14

4.9 Text Styles/Fonts………………………………………………………………………………………………….14

4.10 North Arrow………………………………………………………………………………………………………….14

4.11 Key Plan………………………………………………………………………………………………………………..14

4.12 Match Lines…………………………………………………………………………………………………………..15

4.13 Dimension Styles………………………………………………………………………………………………….15

4.14 Line Types…………………………………………………………………………………………………………….15

Page 3: FLUOR – B & W Portsmouth, LLC On-Site Waste Disposal Facilityfbportsmouth.com/docs/Solicitations/ILTS-2014/1 - FBP OSWDF CADD... · FLUOR – B & W Portsmouth, LLC On-Site Waste

Page 3 of 397/24/2014

_______________________________________________________________MicroStation CADD Standards and Procedures

4.15 Standard Cell Libraries……………………………………………………………………………………..15

4.16 Microstation Color Table…………………………………………………………………………………..15

4.17 Hold Clouds……………………………………………………………………………………………………….15

4.18 View/Section Labeling………………………………………………………………………………………15

5.0 Finalization of CADD Deliverables.........................................................16

5.1 Electronic Drawing File Preparation………………………………………………………………..16

5.2 Transmitting Electronic Drawing Files……………………………………….……………………16

6.0 Plotting…………………………………………………………………………….………………………………….17

Table 1 – Directory Structure OSDC CADD Environment……………………….………….18

Table 2 Common Scale Factors for Cells, Patterns, Border Sheets and Plotting ………………………………..…………………………………………………………..19

Table 3 – Common Text Size Settings – Architectural/Engineering Factors…20

Table 4 - OSDC Standard Files………….………………………………….……………….21

Table 5 – Seed File Default Settings……………………………….…….……………………………….22

Table 6 – OSDC Standard Text Styles…………………………….….…………………………………..23

Table 7 – OSDC Standard Dimension Styles……………….………….……………………………..25

Table 8 – Level Names…………….………………………………………………………………………………...26

Page 4: FLUOR – B & W Portsmouth, LLC On-Site Waste Disposal Facilityfbportsmouth.com/docs/Solicitations/ILTS-2014/1 - FBP OSWDF CADD... · FLUOR – B & W Portsmouth, LLC On-Site Waste

Page 4 of 397/24/2014

_______________________________________________________________MicroStation CADD Standards and Procedures

1.0 ScopeThe purpose and intent of this CADD Manual is to document and organize the multi- discipline CADD standards and procedures to be utilized by all personnel involved with the production of CADD drawings for the FBP OSDC Project.

2.0 General Setup and Configuration

2.1 Coordinate System The coordinate system to be used for all OSDC related design shall be Ohio State

Plane South, based on North American Datum 1983 (NAD83).

2.2 UnitsAll CADD Design will be done using English measurements and the U.S. Survey Foot.

2.3 Design Software Bentley Microstation is the primary design tool for the OSDC project. The

intent is that all drawings are produced with Microstation and the inRoads suite. AutoCAD may be used for certain pre-existing plant-specific modification projects or as needed.

The table below shows the software available for use on the OSDC project.

Platforms Version

MicroStation V8iInRoads Suite V8iAutoCAD 2013AutoCAD Civil 3D 2013

2.4 Data Access

Each user must appropriate access to the secured network as well as access to the project’s secured directory in order to work on the project.

Client : DOEProject : Portsmouth Gaseous Diffusion Plant Decommissioning &

Decontamination ProjectContract No : DE-AC30-10CC40017Project Directory : T:\F0000_ER\F6000 ER On-Site Disposal CellCADD Directory : T:\F0000_ER\F6000 ER On-Site Disposal Cell\F6200 CADD

Page 5: FLUOR – B & W Portsmouth, LLC On-Site Waste Disposal Facilityfbportsmouth.com/docs/Solicitations/ILTS-2014/1 - FBP OSWDF CADD... · FLUOR – B & W Portsmouth, LLC On-Site Waste

Page 5 of 397/24/2014

_______________________________________________________________MicroStation CADD Standards and Procedures

2.5 MicroStation ConfigurationFBP has a virtual server based MicroStation configuration designed for reliability and ease of maintenance.

A network server pools FBP licenses.All MicroStation resource files and data relating to CADD production reside under the root directory T:\F000_ER\F6000 ER On-Site Disposal Cell\F6200 CADD\MS-STD\Workspace\Std except the license server files. Table 1 lists the directory structure for FBP’s CADD environment.

2.6 Configuration VariablesThere are several custom configuration variables included in FBP’s CADD environment. These variables are directory path shortcuts. They are designed to facilitate access to resource maps, standard cell libraries, seed files.

3.0 Drawing Standards

3.1 Drawing Sizes

Arch E1 (30” X 42”) – Primary border for design and construction drawings.ANSI B - (11” X 17”) – Alternate reduced size border for special circumstances.ANSI A - (8.5” X 11”) – Letter size border for exhibits and stand alone details.

3.2 Drawing Borders

All drawings created for design or construction shall be done utilizing OSDC standard drawing borders

3.2.1 Standard Border Files

FBP-E1-LANDSCAPE.DGN (Arch E1, 30” X 42”)FBP-B-LANDSCAPE.DGN (ANSI B – 11” X 17”)FBP-A-PORTRAIT.DGN (ANSI A – 8.5” X 11”)

3.2.2 Insertion of Border Into A drawing

Borders are to be inserted into drawings by referencing the desired standard border file and copying the text from the various fields into the drawing for modification.When the desired text, scaling and layout are finalized, the standard border file reference may be “merged to master,” thereby making the border a part of the file.

3.2.3 Filling Out The Title Block Section Of A Border The numbered items below are instructions on how to use the various components in the title block. The numbers coincide with Figure 1.

Page 6: FLUOR – B & W Portsmouth, LLC On-Site Waste Disposal Facilityfbportsmouth.com/docs/Solicitations/ILTS-2014/1 - FBP OSWDF CADD... · FLUOR – B & W Portsmouth, LLC On-Site Waste

Page 6 of 397/24/2014

_______________________________________________________________MicroStation CADD Standards and Procedures

FIG 1

1. REV: The current revision of the drawing

2. DRAWING NUMBER:

3. SHEET Number: 1 of X

4. DESIGNED BY: Three initials. Example: ABC

5. CHECKED BY: Three initials. Example: ABC

6. DATE: Enter the drawing approval date in the format of MMDDYY.

Example: 10-17-11.

Contract NO: Provided by Contract

7. SCALE: Scale of drawing, Example: 1:1; 1:200, NO SCALE (if non-scaled)

8. DRAWING TITLE:

First Row Title: Project/Facility – (Eg.“IMTA HAUL ROAD”)

Second Row Title: Description of Drawing

Third Row Title: Description of Drawing

Fourth Row Title: Description of Drawing

9. FBP LOGO

10. FBP PROPRIETARY STATEMENT

11. APPROVALS: Electronic Signatures. FBP: Engineer sign off area.

FBP: Manager sign off area.

12. Revisions. Refer Number to Section 3.4 for revision procedure.

Revision Description: Indicate purpose of revision.By: Indicate the CADD Designer three digit initials.Chk: Indicate the checkers three digit initials.Appv: Indicate the approvers’ three digit initials.Date: Indicate the approvers’ sign off date.-The last entry of the revision should match the revision block.-List revisions from bottom to top.

13. Reference Drawings:List any pertinent reference drawing numbers as needed.

Page 7: FLUOR – B & W Portsmouth, LLC On-Site Waste Disposal Facilityfbportsmouth.com/docs/Solicitations/ILTS-2014/1 - FBP OSWDF CADD... · FLUOR – B & W Portsmouth, LLC On-Site Waste

Page 7 of 397/24/2014

_______________________________________________________________MicroStation CADD Standards and Procedures

14. Ohio EPA Plan Set Index Sheet Numbering (If applicable) or Other

3.3 Drawing Numbering and File Naming Standards

This section outlines the project standard naming convention for drawing numbers, revision numbers, and the naming of electronic drawing files.

3.3.1 Drawing Number Assignments

FBP RMDC is responsible for assigning OSDC a block of unique drawing numbers for use on the project.

The block of unique numbers assigned to OSDC: 10000-19999

3.3.2 Drawing Numbering

Drawing numbers and file names shall follow the same format as shown in this example: X-780-C-XXXXX-SK-REV-A.DGN

DISCIPLINE LETTER CODE

The following characters define the file’s engineering discipline.

A – Architectural L – LandscapeC – Civil M - MechanicalE – Electrical R – Right Of WayG – General S – Structural H – Hydraulics V – SurveyI – Instrumentation T – Geotecnical

3.4 Drawing Revisions

3.4.1 “Preliminary - Not For Construction” DrawingsAll official drawings which may be produced for the purpose of generating preliminary engineering planning, cost estimates, construction sequencing and phasing, bids, agency approvals and or any other engineering study shall have an Alphanumeric Revision Number, beginning with the letter A, assigned as part of the drawing name.

These revisions will change sequentially as new iterations of the drawing design are modified. All of these revisions will be noted in the drawing title block and in the

Revision Designator (If applicable)

File Type ExtensionRevision Number/Letter (If applicable)

X-780-C-XXXXX-SK-REV-A.DGN

Regional FacilityArea or Facility Number

Master Discipline CodeUnique Drawing Number

Sketch Designator

Page 8: FLUOR – B & W Portsmouth, LLC On-Site Waste Disposal Facilityfbportsmouth.com/docs/Solicitations/ILTS-2014/1 - FBP OSWDF CADD... · FLUOR – B & W Portsmouth, LLC On-Site Waste

Page 8 of 397/24/2014

_______________________________________________________________MicroStation CADD Standards and Procedures

drawing revision description blocks. All drawings will also have a “Preliminary Not for Construction” stamp located in the lower right hand corner above the title block.

(e.g.) Rev A, Rev B, Rev C, …

3.4.2 “Certified For Construction” (CFC) Drawings

All official drawings which are released for the purpose of construction at the project site shall have a Numeric Revision Number, beginning with the number (0) zero, assigned as part of the drawing name.

(e.g.) Rev 0, Rev 1, Rev 2, …

These revisions will change sequentially as necessary if revised Design Changes are required to adjust previously approved drawings. All of these revisions will be noted in the drawing title block and in the drawing revision description blocks. These drawings will also have a “Certified for Construction” stamp located in the lower right hand corner above the title block.

3.4.3 Revising between CFC and Non-CFC versions of the same drawing

In the case that a CFC drawing needs revised and the revision is not meant to return to CFC until review and a following revision – an alphanumeric system as follows shall be used.

(e.g.) Rev 2 (CFC) is revised for sending to agencies for approval. It becomes Rev 2A, then 2B, etc. until the drawing is meant to become CFC again. At such time it becomes Rev 3.

3.4.4 General Revision Procedures

*All CFC drawings will only be issued through the Records, Management andDocument Control processing service.

*Each revised area or change item on a drawing after Rev 0 is indicated with a revision cloud and a revision triangle as general practice unless it is deemed for special purposes that the drawing is clearer without the revision clouds and triangles. Place clouds and revision triangles on separate levels (G-ANNO-REVC and G-ANNO-REVS, respectively.)

*For overflow revisions that exceed the allocated revision spaces - erase the bottom revision and move all revisions down to allow for the latest revision at the top.

Page 9: FLUOR – B & W Portsmouth, LLC On-Site Waste Disposal Facilityfbportsmouth.com/docs/Solicitations/ILTS-2014/1 - FBP OSWDF CADD... · FLUOR – B & W Portsmouth, LLC On-Site Waste

Page 9 of 397/24/2014

_______________________________________________________________MicroStation CADD Standards and Procedures

4.0 General Drafting Standards

4.1 CADD File Types

The following CADD files types are used for the OSDC project.

Master FilesSheet FilesBorder Files Reference Files

4.1.1 Master FilesA Master file may be utilized if desired to contain the bulk of the actual design information for one or more drawings. Master files are created with 3-dimensional seed files even if the elements within the files are meant to be viewed as 2-dimensional. Master files should not contain scale-specific graphics (i.e.: north arrows, graphic scales, sheet titles or labels).

Each Master file typically contains information associated with only one discipline (ie.: Civil, Electrical, Mechanical, etc.) This separation of information must be maintained even when producing multi-disciplined drawings.

Master files are always drawn “Full Size”, that is, one inch equals one inch and one foot equals one foot.

MASTER FILE NAMES

5.1 SHEET FILE N

3 4 1643 4

X P P C d g n17 18

1 ._ P P _ C Z I V L1 3 4565 6 7 8 9 10 11 12 13 14 15 17

Master Discipline Code

Unique Designation

File Extension

Facility Area Number

Dash: Positions 2, 7 & 10

2

-

Regional Facility

Page 10: FLUOR – B & W Portsmouth, LLC On-Site Waste Disposal Facilityfbportsmouth.com/docs/Solicitations/ILTS-2014/1 - FBP OSWDF CADD... · FLUOR – B & W Portsmouth, LLC On-Site Waste

Page 10 of 397/24/2014

_______________________________________________________________MicroStation CADD Standards and Procedures

ArchitecturalMaster fileX-730-AZ-ARCH1.dgn

Floor Plans1. Roof and Ceiling Plans2. Unassigned3. Sections4. Exterior Elevations5. Interior Elevations6. Unassigned7. Unassigned8. Presentation

CivilMaster fileX-780-CZ-CIVL1.dgn1 Geographical Structures, Buildings, Roads, Reservoirs, Dams2 Grading3 Yard piping4 Horizontal Alignment5 Profiles

6 Utilities7 Pipeline Structures8 Sections/Details9 Unassigned

ElectricalMaster FileX-780-EZ-Elec1.dgn1 Site Plans2 Site underground electrical distribution3 Site grounding systems4 Site lighting & communications systems5 Facility/building plans6 Facility/building non-standard details7 Unassigned8 Unassigned9 Unassigned

HydraulicsMaster fileX-780-HZ-HYDR1.dgn

-

Page 11: FLUOR – B & W Portsmouth, LLC On-Site Waste Disposal Facilityfbportsmouth.com/docs/Solicitations/ILTS-2014/1 - FBP OSWDF CADD... · FLUOR – B & W Portsmouth, LLC On-Site Waste

Page 11 of 397/24/2014

_______________________________________________________________MicroStation CADD Standards and Procedures

1 Plans of dams, reservoirs2 Unassigned3 Unassigned4 Horizontal alignments5 Profile6 Unassigned7 Unassigned8 Unassigned9 Unassigned

LandscapeMaster FileX—780-LZ-Land0.dgn0 General notes, Legend, Planting Plan

1 Planting2 Irrigation

MechanicalMaster FileX-780-MZ-Mech0.dgn0 Existing facilities1 Mechanical equipment2 Process piping plans and sections3 Unassigned

4 Unassigned5 Unassigned6 HVAC plans and sections7 Presentation drawings

SurveyMaster FileX-780-V-XXXXX.dgn1 Measurement lines2 Topographic features3 Surface features4 Property lines5 Easement lines6 Unassigned7 Unassigned8 Unassigned9 Unassigned

Page 12: FLUOR – B & W Portsmouth, LLC On-Site Waste Disposal Facilityfbportsmouth.com/docs/Solicitations/ILTS-2014/1 - FBP OSWDF CADD... · FLUOR – B & W Portsmouth, LLC On-Site Waste

Page 12 of 397/24/2014

_______________________________________________________________MicroStation CADD Standards and Procedures

StructuralMaster FileX-780-SZ-Struc1.dgn1 Foundation2 Sections

GeneralMaster File* Usually there is no General Master for processes

4.1.2 Sheet FilesSheet Files contain everything needed to be plotted as an actual drawing product. They are a combination of referenced master files (when applicable), design graphics, border, drawing annotation/text, north arrow, and graphic scale, etc. Sheet Files are created with the same seed files as Master Files.

For each sheet file, a single border file is attached as a reference file via the ‘saved view’ function and then scaled to the desired plot scale. See Table 3 for typical scale factors. In each case, design data is drawn full-size, and the plotting scale is established by scaling the border sheet reference file.

4.1.3 Border Files

Section 3.2.1 lists the seed border files. The level assignments and content of border file graphics are established per OSDC standards and are not be changed without prior authorization.

Engineer’s stampsEngineer stamps are placed within the border and assigned levels by

discipline. Border file level assignments are shown in Table 8.

4.1.4 Reference FilesReference files are anything from topographic maps, survey files and other background maps, to data points such as boring locations in a coordinate system, etc. The graphic elements in reference files are placed in their proper geographic position within the Ohio State Plane South Coordinate system. They are usually 3D models with the elements placed at the correct geographic elevations except for annotations and grid lines. Annotation is accepted in Reference Files such as contour elevations and surface object identification if necessary. See Table 8 for pertinent levels & information.

4.2 Level Conventions

Level naming convention is dictated by this manual and shall be used for all OSDC work, whether the work is produced in-house or by an outside contractor or

Page 13: FLUOR – B & W Portsmouth, LLC On-Site Waste Disposal Facilityfbportsmouth.com/docs/Solicitations/ILTS-2014/1 - FBP OSWDF CADD... · FLUOR – B & W Portsmouth, LLC On-Site Waste

Page 13 of 397/24/2014

_______________________________________________________________MicroStation CADD Standards and Procedures

consultant. Additional levels may be created as the need arises. Any additional levels should follow the convention set forth in Table 8 which describes the list of levels and their associated symbology.

4.3 Pen Tables

FBP OSDC uses Projectwise InterPlot software for plotting in Microstation. PW IPLOT supports the use of design scripts to establish certain plotting characteristics and capabilities. There are two custom design scripts one each for full-size and half-size plotting in monochrome (black/white). There are two custom design scripts forcolor plotting. The four standard design scripts are:

FBP FULL.PEN Full-size black/white plottingFBP HALF.PEN Half-size black/white plottingFBP FULL COLOR.PEN Full Size color plottingFBP FULL COLOR RASTER Color plotting over raster images

4.4 Line weights Each of the 32 line weights available within MicroStation are explicitly defined in terms of line width. The full-size Design Scripts match line widths to equivalent technical pen sizes. Half-size Design Scripts reduce these line widths by 50%.

4.5 Line Styles The seven basic line styles available within MicroStation (line styles 1 through 7) are customized for FBP’s needs. The plotted line styles vary slightly from the styles displayed on-screen. Half-size line styles are 50% reductions of the full-size.

4.6 Half-tonelinework

Any Reference File with a “cont” Logical Name Prefix will be screened when plotted to create a half-tone effect. This is useful for de-emphasizing certain parts of a drawing, for example when differentiating between existing and proposed items. Also, the color 120 may be used to achieve screening as well but is a secondary option.

4.7 Plot Stamp A special character string in FBP border which are replaced atthe time of plotting with file name (including path), three-letter user designator, plot time, and pen table applied to the plotted design file.

Page 14: FLUOR – B & W Portsmouth, LLC On-Site Waste Disposal Facilityfbportsmouth.com/docs/Solicitations/ILTS-2014/1 - FBP OSWDF CADD... · FLUOR – B & W Portsmouth, LLC On-Site Waste

Page 14 of 397/24/2014

_______________________________________________________________MicroStation CADD Standards and Procedures

4.8 Seed Files

File NameFBPSeed2D.dgnFBPSeed3D.dgnFBPSeed_Detail.dgn

FBP OSDC has several seed files to be used according to certain needs. .

UseDefault 2D seed fileDefault seed file for the bulk of design elements.Seed file for creating Architectural Details

4.9 Text Styles / Fonts

The standard font to be used for drawings is the TRUE TYPE font, “VERDANA”.

All text for drawings must be UPPER CASE unless a specific need arises for the use of lower case characters.

Text height as listed below shall be used for drawings created using ANSI A andANSI B paper sizes.

3/32”, width factor 0.85 - Text (Dimensions, Annotations, Notes, etc.)1/8”, width factor 0.85 – Matchline text and sub-titles.3/16”, width factor 0.75 –Title text (including for sections and details)

Text height as listed below shall be used for drawings created using theArch E1 paper size.

1/8”, width factor 0.85 – Text (Dimensions, Annotations, Notes, etc.)3/16”, width factor 0.85 – Matchline text and sub-titles.1/4”, width factor 0.75 – Title text (including for sections and details)

Note: Sketches and presentation drawings that are not to become official project drawings may use other fonts and font sizes as necessary.

4.10 North Arrow

The north arrow is required for all plans with its location at the upper right corner of the drawing and is also part of the key plan.

The cell name is NORTHA. See below for correct image (not to scale).

4.11 Key Plan A key plan may be used to better identify a design element’s location. It will

be located on the drawing in a relevant location to help clarify the graphics.

Page 15: FLUOR – B & W Portsmouth, LLC On-Site Waste Disposal Facilityfbportsmouth.com/docs/Solicitations/ILTS-2014/1 - FBP OSWDF CADD... · FLUOR – B & W Portsmouth, LLC On-Site Waste

Page 15 of 397/24/2014

_______________________________________________________________MicroStation CADD Standards and Procedures

4.12 Match LinesMatch Lines are used for continuations between drawings or between different

design elements within the same drawing

4.13 Dimension StylesAll dimensions are associative. Default dimension styles and text styles for appropriate scales shall used in all cases and shall match in text height.

The default dimension styles are listed in Table 7.

Note: Dimension styles may be added/deleted/updated as needed.

4.14 Line TypesWhen designing with Microstation, use only linetypes that are defined in MicroStation Resource Libraries such as the following:

FBP Line Style 1.RSCFBP Line Style 2.RSCFBP Line Style 3.RSCFBP Line Style 4.RSCFBP Line Style 5.RSC

Note: MicroStation Resource Libraries may be updated as needed.

4.15 Standard Cell librariesARCHPA_V8.CEL-ARCHITECTURAL PATTERNINGARCH_V8.CEL-ARCHITECTURAL FLOOR PLAN SYMBOLSARCH50.CEL- STANDARD DRAWINGS SYMBOLSBEND.CEL-PIPE BENDSCIVILMSTR.CEL-GENERAL CIVIL SYMBOLSDRAWING_V8.CEL-GENERAL DRAFTING SYMBOLSGENERAL8_V8.CEL-GENERAL DRAWING SYMBOLSLAND.CEL-GENERAL LANDSCAPE SYMBOLSTREE.CEL-LANDSCAPE TREE SYMBOLSFBP EXISTING 1. CEL – EXISTING CIVIL SYMBOLSFBP EXISTING 2. CEL – EXISTING CIVIL SYMBOLSENG_ STAMPS.CEL – ENGINEERS PROFESSIONAL STATE SEAL

4.16 MicroStation Color TableThe standard project file color table, FBPColor.TBL is included with the DGNLIB File.

4.17 Hold CloudsHold Clouds are used on a “Certified For Construction” drawing to indicate specific design elements that are not to be constructed. The desired area is distinguished witha cloud and the text, “HOLD.”

4.18 View/Section Labeling

Section views are identified by use of the letters in consecutive order as A, B, C, etc. Section cuts that reference to another drawing shall indicate the drawing

that it references to. If the section cut is referenced on the same drawing “THIS DRAWING” is indicated. MicroStation cell name = SEC*

Page 16: FLUOR – B & W Portsmouth, LLC On-Site Waste Disposal Facilityfbportsmouth.com/docs/Solicitations/ILTS-2014/1 - FBP OSWDF CADD... · FLUOR – B & W Portsmouth, LLC On-Site Waste

Page 16 of 397/24/2014

_______________________________________________________________MicroStation CADD Standards and Procedures

Enlarged/detail views are identified by use of numbers in consecutive order, as 1, 2, 3, etc. MicroStation cell name =DET*. Details that are referenced to

another drawing shall indicate the drawing number otherwise “THIS DRAWING” is indicated.

Section and views "cut" on one drawing and shown or projected on another drawing will need to indicate the drawing number in the title labeling. The view or section labeling shall also include the scale.

Microstation cell name =DSTITL;

5.0 Finalization of CADD Deliverables

5.1 Electronic Drawing File Preparation

When requested as a deliverable, completed electronic sheet files shall be “merged to master” with all elements from master, reference, and border files merged into the drawing as graphics. Topography/Lidar/Imagery may remain as references if necessary for file size and must be submitted with the “merged to master” file. All working sheet files, master files, border files, and reference files shall be retained and submitted upon request.

5.2 Transmitting Electronic Drawing Files

All CADD drawings transmitted to a NON-FBP recipient must be in PDF format unless the transfer of native format files has been approved by OSDC

management.

Page 17: FLUOR – B & W Portsmouth, LLC On-Site Waste Disposal Facilityfbportsmouth.com/docs/Solicitations/ILTS-2014/1 - FBP OSWDF CADD... · FLUOR – B & W Portsmouth, LLC On-Site Waste

Page 17 of 397/24/2014

_______________________________________________________________MicroStation CADD Standards and Procedures

6.0 PlottingFBP uses Bentley Systems ProjectWise InterPlot and Interplot Organizerapplications as the primary MicroStation plotting interface. Plot files are

submitted through the ProjectWise enterprise network to print queues dedicated to CADD production. Batch plotting is done with Bentley Systems ProjectWiseInterPlot Organizer software.

Plot queue settings files have file names matching the queue name. Other settings files used in conjunction with the plot queue setting files are:

Settings files PW_IPLOT_FBP_11x17-REDUCED.set and PW_IPLOT_FBP_30x42-Full.set do not require a fence and will exclude the cut line from the printed plot when plotted via Iplot and used in conjunction with FBP’s latest standard border file.

Page 18: FLUOR – B & W Portsmouth, LLC On-Site Waste Disposal Facilityfbportsmouth.com/docs/Solicitations/ILTS-2014/1 - FBP OSWDF CADD... · FLUOR – B & W Portsmouth, LLC On-Site Waste

Page 18 of 397/24/2014

_______________________________________________________________MicroStation CADD Standards and Procedures

TABLE 1Directory Structure OSDC CADD Environment

GENERAL SYSTEM PATHS

Root Path (system variable)CAD_DATA = T:\F00000_ER\F6000-ER On-Site Disposal\F6200 CADD\

Path to MicroStation Vi8 settings

CAD_DATA\FBP MS-STD\Workspace\

Path to FBP Custom Macros & ApplicationsCAD_DATA\MS-STD\Workspace\Apps

Path to Users Personal Interface FolderCAD_DATA\MS\STD\Workspace\Users

Path to Project Configuration FilesCAD_DATA\MS-STD\Workspace\Config

Typical Project Folder Structure.(See page 36)

Page 19: FLUOR – B & W Portsmouth, LLC On-Site Waste Disposal Facilityfbportsmouth.com/docs/Solicitations/ILTS-2014/1 - FBP OSWDF CADD... · FLUOR – B & W Portsmouth, LLC On-Site Waste

Page 19 of 397/24/2014

_______________________________________________________________MicroStation CADD Standards and Procedures

TABLE 2

Common Scale Factors ForCells, Patterns, Border Sheets, and Plotting

DWG SCALE CELLS & PATTERNS* BORDER SHEET PLOT SCALE

(AS=) (PS=) (REF. FILE SCALE) (FEET / INCH)

Full Size .1 1:1 1:126” = 1’-0” .2 2:1 1:63” = 1’-0” .4 4:1 1:4

1 ½” = 1’-0” .8 8:1 1:81” = 1’-0” 1.2 12:1 1:1¾” = 1’-0” 1.6 16:1 4:3½” = 1’-0” 2.4 24:1 2:13/8” = 1’-0” 3.2 32:1 8:3¼” = 1’-0 4.8 48:1 4:13/16” = 1’-0” 6.4 64:1 16:31/8” = 1’0” 9.6 96:1 8:13/32” = 1’-0” 12.8 128:1 32.31/16” = 1’-0” 19.2 192:1 16:11/32” = 1’-0” 38.4 384:1 32:1

1” = 10’ 12 120:1 10:11” = 20’ 24 240:1 20:11” = 25’ 30 300:1 25:11” = 30’ 36 360:1 30:11” = 40’ 48 480:1 40:11” = 50’ 60 600:1 50:11” = 60’ 72 720:1 60:11” = 80’ 96 960:1 80:11” = 100’ 120 1200:1 100:11” = 150’ 180 1800:1 150:11” = 200’ 240 2400:1 200:11” = 300’ 360 3600:1 300:11” = 400’ 480 4800:1 400:11” = 500’ 600 6000:1 500:11” = 1000’ 1200 12000:1 1000:11” = 2000’ 2400 24000:1 2000:11” = 3000’ 3600 36000:1 3000:1

Page 20: FLUOR – B & W Portsmouth, LLC On-Site Waste Disposal Facilityfbportsmouth.com/docs/Solicitations/ILTS-2014/1 - FBP OSWDF CADD... · FLUOR – B & W Portsmouth, LLC On-Site Waste

Page 20 of 397/24/2014

_______________________________________________________________MicroStation CADD Standards and Procedures

Table 3Architectural Scale Factors (imperial units)

Scale DrawingPlotted Text Height

of Scale 3/32" Size 1/8" Size 3/16" Size 1/4"Drawing (Dimscale) (Title Text) (HOLD/

Stamp Text)Actual Text Height

(inches)(In Model)

1"=1"(FULL) 1 .09375 0.125 0.1875 0.253"=1'-0" 4 .375 0.5 0.75 11-1/2"=1'0" 8 .75 1 1.5 21"=1'-0" 12 1.125 1.5 2.25 33/4"=1'-0" 16 1.5 2 3 41/2"=1'-0" 24 2.25 3 4.5 63/8"=1'-0" 32 3 4 6 81/4"=1'-0" 48 4.5 6 9 123/16"=1'-0" 64 6 8 12 161/8"=1'-0" 96 9 12 18 243/32"=1'-0" 128 12 16 24 321/16"=1'-0" 192 18 24 36 481/32"=1'-0" 384 36 48 72 96

Page 21: FLUOR – B & W Portsmouth, LLC On-Site Waste Disposal Facilityfbportsmouth.com/docs/Solicitations/ILTS-2014/1 - FBP OSWDF CADD... · FLUOR – B & W Portsmouth, LLC On-Site Waste

Page 21 of 397/24/2014

_______________________________________________________________MicroStation CADD Standards and Procedures

Table 3 (Continued)Engineering Scale Factors (imperial units)

Scale Drawing Plotted Text Heightof Scale 3/32" Size 1/8" Size 3/16" Size 1/4"

Drawing (Dimscale) (Title Text) (HOLD/Stamp Text)

Actual Text Height (inches)(In Model)

1"=10' 120 11.25 15 22.75 301"=20' 240 22.25 30 45 601"=30' 360 33.75 45 67.5 901"=40' 480 45 60 90 1201"=50' 600 56.25 75 112.5 1501"=60' 720 67.5 90 135 1801"=80' 960 90 120 180 2101"=100' 1200 112.5 150 225 3001"=200' 2400 225 300 450 6001"=300' 3600 337.5 450 675 7501"=400' 4800 450 600 900 12001"=500' 6000 562.5 750 1125 1500

TABLE 4OSDC Standard Files

This table lists standard resource files in FBP CADD environment.

Filename Description

FBPseed3D.dgnlib DGN library of levels, text styles and dimension stylesARCHPA_V8.CEL ARCHITECTURAL PATTERNINGARCH_V8.CEL ARCHITECTURAL FLOOR PLAN SYMBOLSARCH50.CEL STANDARD DRAWING SYMBOLSBEND.CEL PIPE BENDSCIVILMSTR.CEL GENERAL CIVIL SYMBOLSDRAWING_V8.CEL GENERAL DRAFTING SYMBOLSGENERAL8_V8.CEL GENERAL DRAWING SYMBOLSLAND.CEL GENERAL LANDSCAPE SYMBOLSTREE.CEL LANDSCAPE TREE SYMBOLSFBP EXISTING 1.CEL EXISTING CIVIL SYMBOLSFBP EXISTING 2.CEL EXISTING CIVIL SYMBOLSENG_STAMPS.CEL ENGINEER’S PROFESSIONAL STATE SEALARCHPA_V8.CEL ARCHITECTURAL FLOOR PLAN SYMBOLS

Eng_Stamps.cel Engineer’s stamps cell library

FBPResources.cfg Configuration file defining variables for resource maps

Page 22: FLUOR – B & W Portsmouth, LLC On-Site Waste Disposal Facilityfbportsmouth.com/docs/Solicitations/ILTS-2014/1 - FBP OSWDF CADD... · FLUOR – B & W Portsmouth, LLC On-Site Waste

Page 22 of 397/24/2014

_______________________________________________________________MicroStation CADD Standards and Procedures

FBPPsiteV8.cfg Configuration file defining the bulk of FBP’s CAD environment

Gshade.ctb Black & white colorFBPcolor.tbl Color table

FBPseed2d.dgn Seed 2-D design fileFBPseed3d.dgn Seed 3-D design file

FBPseed2d – detail.dgn Seed detail fileFBP-A-Potrait.dgn A-size border sheetFBP-B-Landscape.dgn B-size border sheetFBP-E1-Landscape.dgn E1-size border sheetWysiwyg.prf Geometrical settings, InRoadsFBPfont.rsc Font Resource fileFBPfont.lib Font Library fileFBP linestyle 1.RSC Civil custom line style resourceFBP linestyle 2.RSC Civil custom line style resourceFBP linestyle 3.RSC Civil custom line style resourceFBP linestyle 4.RSC Civil custom line style resourceFBP linestyle 5.RSC Civil custom line style resource

TABLE 5Seed File Default Settings

Additional settings

Locks

Axis Lock OffGrid Lock OffUnit Lock OffAssociation OnLevel Lock OffIsometric Lock OffSnap Lock Keypoint

Keysnap Divisor 2

Display attributes

ACD Triad Off Fast Cell Off

Background Off Fast Curves Off

Boundary Display

Off Fast Font Off

Camera Off Fill On

Page 23: FLUOR – B & W Portsmouth, LLC On-Site Waste Disposal Facilityfbportsmouth.com/docs/Solicitations/ILTS-2014/1 - FBP OSWDF CADD... · FLUOR – B & W Portsmouth, LLC On-Site Waste

Page 23 of 397/24/2014

_______________________________________________________________MicroStation CADD Standards and Procedures

Clip Back On Grid Off

Clip Volume On Line Styles On

Constructions On Line Weights

On

Dimensions On Patterns On

Dynamics On Tags On

Data Fields Off Text On

Displayset Off Text Off

TABLE 6OSDC Standard Text Styles

This table lists pre-defined OSDC Standard Text Styles. Creation of new or customization of existing styles is not allowed.

Name (Description)

Text Size

H W Line Spacing Level

Verdana 1-2 0.0039 00039 44% of Height G-ANNO-Text

Verdana 1-1 0.0078 0.0065 44% of Height G-ANNO-Text

Verdana 1-1/2 0.0625 0.0521 44% of Height G-ANNO-Text

Verdana – 1-10 0.9375 0.7812 44% of Height G-ANNO-Text

Verdana – 1-100 9.3750 7.8120 44% of Height G-ANNO-Text

Verdana 1-1000 93.7498 78.1248 44% of Height G-ANNO-Text

Verdana 1-20 1.870 1.5625 44% of Height G-ANNO-Text

Verdana 1-200 18.7500 15.625 44% of Height G-ANNO-Text

Verdana 1-30 2.8125 2.3437 44% of Height G-ANNO-Text

Verdana 1-40 3.7500 3.1250 44% of Height G-ANNO-Text

Verdana 1-50 4.6875 3.9062 44% of Height G-ANNO-Text

Verdana 1-500 46.8749 39.0624 44% of Height G-ANNO-Text

Verdana 1/16 1.5000 1.2500 44% of Height G-ANNO-Text

Verdana 1/2 0.1875 0.1562 44% of Height G-ANNO-Text

Page 24: FLUOR – B & W Portsmouth, LLC On-Site Waste Disposal Facilityfbportsmouth.com/docs/Solicitations/ILTS-2014/1 - FBP OSWDF CADD... · FLUOR – B & W Portsmouth, LLC On-Site Waste

Page 24 of 397/24/2014

_______________________________________________________________MicroStation CADD Standards and Procedures

Verdana 1/4 0.3500 0.3125 44% of Height G-ANNO-Text

Verdana 1/8 0.7500 0.6250 44% of Height G-ANNO-Text

Verdana 1=1 0.0938 0.0797 44% of Height G-ANNO-Text

Verdana 3-1 0.312 0.0260 44% of Height G-ANNO-Text

Verdana 3/16 0.5000 0.4167 44% of Height G-ANNO-Text

Verdana 3/32 1.000 0.8333 44% of Height G-ANNO-Text

Verdana 3/4 0.1250 0.1042 44% of Height G-ANNO-Text

Verdana 3/8 0.2500 0.7083 44% of Height G-ANNO-Text

Verdana 6-1 0.0156 0.0130 44% of Height G-ANNO-Text

Verdana Title 1-1 0.0156 0.0117 44% of Height G-ANNO-Text

Verdana Title 1-1/2 0.1250 0.0937 44% of Height G-ANNO-Text

Verdana Title 1-10 1.8750 1.4062 44% of Height G-ANNO-Text

Verdana Title 1-100 18.7500 14.0625 44% of Height G-ANNO-Text

Verdana Title 1-1000 187.4996 140.6247 44% of Height G-ANNO-Text

Verdana Title 1-20 3.750 W=2.8125 44% of Height G-ANNO-Text

Verdana Title 1-200 37.4999 28.1249 44% of Height G-ANNO-Text

Verdana Title 1-30 5.6250 4.2187 44% of Height G-ANNO-Text

Verdana Title 1-40 7.5000 5.625 44% of Height G-ANNO-Text

Verdana Title 1-50 9.3750 7.0312 44% of Height G-ANNO-Text

Verdana Title 1-500 93.7498 70.3124 44% of Height G-ANNO-Text

Verdana Title 1/16 3.000 2.2500 44% of Height G-ANNO-Text

Verdana Title 1/2 0.3750 0.2812 44% of Height G-ANNO-Text

Verdana Title 1/4 0.7500 0.5625 44% of Height G-ANNO-

Verdana 1/8 1.500 1.1250 44% of Height G-ANNO-Text

Verdana Title 3-1 0.0625 0.0469 44% of Height G-ANNO-Text

Verdana Title 3/16 1.000 0.7500 44% of Height G-ANNO-Text

Verdana Title 3/32 2.000 1.5000 44% of Height G-Ann 0-Text

Page 25: FLUOR – B & W Portsmouth, LLC On-Site Waste Disposal Facilityfbportsmouth.com/docs/Solicitations/ILTS-2014/1 - FBP OSWDF CADD... · FLUOR – B & W Portsmouth, LLC On-Site Waste

Page 25 of 397/24/2014

_______________________________________________________________MicroStation CADD Standards and Procedures

Verdana Title 3/4 0.2500 0.1875 44% of Height G-Ann 0-Text

Verdana Title 3/8 0.500 0.3750 44% of Height G-Ann 0-Text

Verdana Title 6-1 0.0312 0.234 44% of Height G-Ann 0-Text

TABLE 7 OSDC Standard Dimension Styles

This table lists pre-defined FBP Standard Dimension Styles. Creation of new orcustomization of existing styles if not allowed.

Name Terminator Orientation Placement Location

Auto: Term Auto Automatic Automatic

Auto: Term In In Manual

Man: Term Auto Automatic Automatic

Man: Term In In Manual

Electrical Loop Automatic Manual

Structural Loop Automatic Manual

Page 26: FLUOR – B & W Portsmouth, LLC On-Site Waste Disposal Facilityfbportsmouth.com/docs/Solicitations/ILTS-2014/1 - FBP OSWDF CADD... · FLUOR – B & W Portsmouth, LLC On-Site Waste

Page 26 of 397/24/2014

_______________________________________________________________MicroStation CADD Standards and Procedures

TABLE 8

Name Number Description ByLevelColor ByLevelStyle

ByLevelWeight

A-ANNO-DIMS 400 Dimensions 2 Continuous

2

A-ANNO-LEGN 401 Legends, symbol keys 0 Continuous

3

A-ANNO-PATT 402 Miscellaneous patterning and hatching 22 Continuous

2

A-ANNO-SCHD 403 Schedules 0 Continuous

3

A-ANNO-SYMB 404 Reference tags (section and detail callouts) 7 Continuous

3

A-ANNO-TABL 405 Data tables 0 Continuous

3

A-ANNO-TEXT 406 Drawing text & annotations, notes, legends 0 Continuous

3

A-ANNO-TITL 407 Drawing or detail titles 0 Continuous

3

A-AREA-BDRY 408 Area: boundaries 70 Center2

3

A-AREA-IDEN 409 Area: Room tags 0 Continuous

3

A-AREA-SPCE 410 Area: Space objects 2 Continuous

2

A-CLNG 411 Ceiling Framing 47 Continuous

3

A-CLNG-GRID 412 Grid 10 Continuous

3

A-CLNG-IDEN 413 Ceiling text and tags 0 Continuous

3

A-CLNG-ONPG 414 Ceiling penetrations (ceiling & roof) 2 Hidden

2

A-CLNG-SUSP 415 Ceiling suspended elements 2 Continuous

2

A-COLS 416 Building Column: steel 11 Continuous

3

A-CSWK 417 Casework 50 Continuous

3

A-DETL-BOLD 418 Bold lines 2 Continuous

2

A-DETL-CNTR 419 Center lines 3 Center2

1

A-DETL-FINE 420 Fine lines 9 Continuous

0

A-DETL-HIDD 421 Hidden lines 3 Hidden2

1

A-DETL-MEDM 422 Medium lines 7 Continuous

3

A-DOOR 423 Doors & holes 1 Continuous

2

A-DOOR-FRAM 424 Door Frame 4 Continuous

2

A-DOOR-IDEN 425 Doors: ID label, tags 7 Continuous

2

A-FLOR-CSWK 426 Floor: casework 51 Continuous

3

A-FLOR-CSWK-IDEN 427 Floor: casework text and tags 0 Continuous

3

A-FLOR-EVTR 428 Floor: Elevator 10 Continuous

3

A-FLOR-FIXT 429 Floor: plumbing fixtures 47 Continuous

3

A-FLOR-HRAL 430 Floor: handrails & guard rails 51 Continuous

3

A-FLOR-IDEN 431 Floor: finish tags 0 Continuous

3

A-FLOR-LEVL 432 Floor: level changes, ramps, pits 11 Continuous

3

A-FLOR-PATT 433 Floor: patterns 0 Continuous

2

A-FLOR-PENE 434 Floor: penetrations 11 Continuous

2

Page 27: FLUOR – B & W Portsmouth, LLC On-Site Waste Disposal Facilityfbportsmouth.com/docs/Solicitations/ILTS-2014/1 - FBP OSWDF CADD... · FLUOR – B & W Portsmouth, LLC On-Site Waste

Page 27 of 397/24/2014

_______________________________________________________________MicroStation CADD Standards and Procedures

A-FLOR-SPCL 435 Floor: specialties,toilet room accessories, display cases 53 Continuous

3

A-FLOR-SPCL-IDEN 436 Floor: specialties text and tags 5 Continuous

2

A-FLOR-STRS 437 Stairs, escalators, ladders & elevator's 51 Continuous

3

A-FLOR-STRS-IDEN 438 Stairs arrow, text 0 Continuous

3

A-FLOR-TEXT 439 Floor: finish text0 Continuous

3

A-FLOR-TPTN 440 Floor: toilet partitions 47 Continuous

3

A-FURN 441 Furniture, Portable Furniture 50 Continuous

3

A-FURN-IDEN 442 Furniture: text and tags 0 Continuous

3

A-GLAZ 443 Window: window over open 2 Continuous

2

A-GLAZ-IDEN 444 Window tags 0 Continuous

3

A-GLAZ-SILL 445 Window: window sills2 Continuous

2

A-LITE 446 Lite: 47 Continuous

3

A-LITE-CLNG 447 Lite: ceiling 47 Continuous

3

A-LITE-WALL 448 Lite: wall 47 Continuous

3

A-ROOF 449 Roo54 Continuous

3

A-WALL 450 Wall: 0 Continuous

3

A-WALL-CNTR 451 Wall: centerline3 Center2

1

A-WALL-EXTR 452 Wall: exterior 11 Continuous

3

A-WALL-FIRE 453 Wall: fire wall 51 Hidden2

3

A-WALL-FULL 454 Wall: full-height 2 Continuous

2

A-WALL-HEAD 455 Wall: door and window headers 3 Continuous

1

A-WALL-IDEN 456 Wall: text and tags 0 Continuous

3

A-WALL-JAMB 457 Wall: door and window jambs3 Continuous

1

A-WALL-MOVE 458 Wall: moveable partition 52 Continuous

3

A-WALL-PATT 459 Wall: patterning 2 Continuous

2

A-WALL-PRHT 460 Wall: partial-height 53 Continuous

3

C-ANNO-DIMS 200 Dimensions 0 Continuous

3

C-ANNO-DIVL 201 Division lines for segmented drawings 5 Dashdot2

5

C-ANNO-NOTE 202 General notes & legend0 Continuous

3

C-ANNO-SCHD 203 Schedules & tables 0 Continuous

3

C-ANNO-SYMB 204 Reference tags (section and detail callouts) 0 Continuous

3

C-ANNO-TEXT 205 Drawing text & annotations 0 Continuous

3

C-ANNO-TITL 206 Drawing or detail titles 0 Continuous

3

C-BLDG 207 Building & architectural information 116 Continuous

4

C-BORE 208 Soil boring and text47 Continuous

3

C-CABLE 0 0

0

C-CLEARING 2 7

2

C-CPT Cone Penetrometer Tests 0 0

3

C-CULV Culvert 0 0

1

C-DEMO 209 Demolition/abandon/removal symbol 52 Continuous

3

C-DETL-BOLD 210 Bold lines115 Continuous

4

Page 28: FLUOR – B & W Portsmouth, LLC On-Site Waste Disposal Facilityfbportsmouth.com/docs/Solicitations/ILTS-2014/1 - FBP OSWDF CADD... · FLUOR – B & W Portsmouth, LLC On-Site Waste

Page 28 of 397/24/2014

_______________________________________________________________MicroStation CADD Standards and Procedures

C-DETL-CNTR 211 Center lines 3 Center2

1

C-DETL-FINE 212 Fine lines 4 Continuous

2

C-DETL-HIDD 213 Hidden lines 0 Hidden2

2

C-DETL-MEDM 214 Medium lines 7 Continuous

3

C-DTCH 215 Ditches, streams and rivers52 Phantom2

4

C-EQPM 216 Equipment outline 114 Continuous

4

C-EQPM-DETL 217 Equipment detail linework 2 Continuous

2

C-EROS 218 Erosion control 48 Continuous

4

C-FENC 219 Fences 54 FENCE

1

C-FENCE-RAD Rad Fence 54 bw

1

C-FENC-SILT54 FESILT

1

C-FIRE 220 Underground fire protection lines/structure 48 Hidden

4

C-GAS 0 0

0

C-GRID 221 Grid lines 4 Continuous

2

C-LEACHATE Leachate Pipe 0 6

1

C-LOCG 222 Clearing and grubbing limit 113 Hidden

3

C-MHOLE Manhole0 0

1

C-MW Monitoring Wells 0 0

3

C-PIEZ Piezometers 0 0

3

C-POND 223 Retention ponds, holding basin 111 Phantom2

4

C-POWR-OVHD 0 OHP_LINE

1

C-POWR-UGND 225 Underground elec. conduit and text 48 Continuous

1

C-PROP 226 Property lines, easement and right of way114 Phantom2

5

C-PROP-BMRK 227 Monuments and text 53 Continuous

3

C-RAIL 228 Railroads 49 Continuous

4

C-ROAD 229 Roads, sidewalks, parking lots 7 Continuous

0

C-ROAD-CNTR 230 Centerline of roads and railroads 7 Center2

2

C-ROAD-PATT 231 Road patterning/hatching 7 Continuous

2

C-ROAD-SHLD 232 Roads/railroad shoulders47 Continuous

3

C-ROAD-STAN 233 Road, railroad stationing 1 Continuous

2

C-SECT 234 Section 3 Continuous

1

C-SECT-DIMS 235 Section dimension 0 Continuous

3

C-SECT-LEGN 236 Section legend 0 Continuous

3

C-SECT-LINE 237 Section line 0 Continuous

3

C-SECT-NOTE 238 Section note0 Continuous

3

C-SECT-TEXT 239 Section text 0 Continuous

3

C-SOIL 240 Topsoil stockpiles 115 Continuous

4

C-SSWR 241 Underground waste line 54 Hidden

4

C-SSWR-STRC 242 Underground waste structure 70 Continuous

4

C-STRC 243 Structural linework 134 Continuous

4

C-STRC-GRID 244 Structural column & grid lines4 Center2

2

Page 29: FLUOR – B & W Portsmouth, LLC On-Site Waste Disposal Facilityfbportsmouth.com/docs/Solicitations/ILTS-2014/1 - FBP OSWDF CADD... · FLUOR – B & W Portsmouth, LLC On-Site Waste

Page 29 of 397/24/2014

_______________________________________________________________MicroStation CADD Standards and Procedures

C-STRM 245 Storm drainage lines50 Continuous

4

C-STRM-STRC 246 Storm drainage structure 11 Continuous

4

C-SURV 247 Survey information and text 10 Continuous

2

C-SURV-MONU Survey Monument 0 0

3

C-TEL0 0

0

C-TOE-OF-SLOPE 3 3

3

C-TOPO-ANNO 0 0

0

C-TOP-OF-SLOPE 3 5

3

C-TOPO-MAJR 248 Index contours 13 Continuous

3

C-TOPO-MINR 249 Intermediate contours 4 Continuous

1

C-TOPO-SPOT 250 Spot elevations54 Continuous

3

C-TREE 251 Foliage 50 Continuous

3

C-UNDEFINED 0 0

0

C-UTIL 252 Miscellaneous underground utility 11 Hidden

4

C-VHOUSE Valve House 0 0

3

C-WASTELIM Limits Of Waste 0 0

1

C-WATR 253 Underground water lines1 Hidden

4

C-WATR-WELL 254 Well and text 47 Continuous

3

D-ANNO-DIMS 600 Dimensions 0 Continuous

3

D-ANNO-PATT 601 Patterning and hatching 6 Continuous

2

D-ANNO-SCHD 602 Schedules & tables 0 Continuous

3

D-ANNO-SYMB 603 Reference tags (section and detail callouts) 7 Continuous

3

D-ANNO-TEXT 604 Drawing text & annotations, notes, legends0 Continuous

3

D-ANNO-TITL 605 Drawing or detail titles 0 Continuous

3

Default 0 0 0

0

D-PROC-BNDY 606 Process boundry 11 Center2

3

D-PROC-CAPI 607 Capilary lines 54 0

3

D-PROC-ELEC 608 Electrical 51 Continuous

3

D-PROC-ELEC-SGNL 609 Electrical signal51 Hidden2

3

D-PROC-EQPM 610 Equipment 115 Continuous

4

D-PROC-FITT 611 Fittings 11 Continuous

3

D-PROC-HYDR 612 Hydraulic lines 47 0

3

D-PROC-INST 613 Instrument 52 Continuous

3

D-PROC-INST-SGNL 614 Instrument signal 52 Hidden2

3

D-PROC-MAJR 615 Major process line13 Continuous

4

D-PROC-MINR 616 Minor process / utility line 47 Continuous

4

D-PROC-MODL 617 Module boundry 10 0

4

D-PROC-PACK 618 Package boundry 54 0

3

D-PROC-PNEU 619 Pneumatic lines 47 0

3

D-PROC-SOFT 620 Software lines 52 0

3

D-PROC-VALV 621 Valves70 Continuous

3

Page 30: FLUOR – B & W Portsmouth, LLC On-Site Waste Disposal Facilityfbportsmouth.com/docs/Solicitations/ILTS-2014/1 - FBP OSWDF CADD... · FLUOR – B & W Portsmouth, LLC On-Site Waste

Page 30 of 397/24/2014

_______________________________________________________________MicroStation CADD Standards and Procedures

E-ANNO-DIMS 1300 Dimensions 2 Continuous

2

E-ANNO-PATT 1301 Patterning and hatching 6 Continuous

2

E-ANNO-SCHD 1302 Schedules & tables 0 Continuous

3

E-ANNO-SYMB 1303 Reference tags (section and detail callouts) 7 Continuous

3

E-ANNO-TEXT 1304 Drawing text & annotations, notes, legends0 Continuous

3

E-ANNO-TITL 1305 Drawing or detail titles 111 Continuous

4

E-AUXL 1306 Auxiliary Systems 113 Continuous

4

E-CABL 1307 Cable systems 54 Continuous

4

E-CABL-COAX 1308 Cable systems: coax cable 54 Continuous

4

E-CABL-DEVC 1309 Cable systems: jacks/outlets 54 Continuous

4

E-CABL-EQPM 1310 Cable systems: equipment racks/panels/cabinets54 Continuous

4

E-CABL-FIBR 1311 Cable systems: fiber optics cable 54 Continuous

4

E-CABL-MULT 1312 Cable systems: multi-conductor cable 115 Continuous

4

E-CABL-TEXT 1313 Cable systems: Text and tags 0 Continuous

3

E-CABL-TRAY 1314 Cable systems: cable tray and wireways 13 Continuous

4

E-CNDT 1315 Conduit: exposed 111 Continuous

4

E-CNDT-HIDD 1316 Conduit: concealed111 Hidden

4

E-COMM 1317 Communications114 Continuous

4

E-DETL-BOLD 1318 Bold lines 115 Continuous

4

E-DETL-CNTR 1319 Center lines 3 Center2

1

E-DETL-FINE 1320 Fine lines 4 Continuous

2

E-DETL-HIDD 1321 Hidden lines 0 Hidden2

2

E-DETL-MEDM 1322 Medium lines7 Continuous

3

E-DIAG-BOLD 1323 Diagrams: Bold lines 117 Continuous

4

E-DIAG-BOLD-HIDD 1324 Diagrams: Bold lines: hidden 117 Hidden2

4

E-DIAG-BOLD-PHAT 1325 Diagrams: Bold lines: phantom 117 Phantom2

5

E-DIAG-FINE 1326 Diagrams: Fine lines 11 Continuous

2

E-DIAG-FINE-HIDD 1327 Diagrams: Fine lines: hidden 11 Hidden2

2

E-DIAG-FINE-PHAT 1328 Diagrams: Fine lines: phantom11 Phantom2

2

E-DIAG-MEDM-1 1329 Diagrams: Medium lines -1 12 Continuous

3

E-DIAG-MEDM-2 1330 Diagrams: Medium lines -2 12 Continuous

4

E-DIAG-MEDM-HIDD 1331 Diagrams: Medium lines: hidden 12 Hidden2

4

E-DIAG-MEDM-PHAT 1332 Diagrams: Medium lines: phantom 12 Phantom2

4

E-GRND 1333 Grounding (Cells & UCM) 115 Continuous

4

E-GRND-UGND 1334 Grounding: below grade50 0

4

E-INST 1335 Instrumentation (cells & UCM) 52 Continuous

4

E-INST-TEXT 1336 Instrumentation: text and tags 0 Continuous

3

E-LITE 1337 Lighting (Cells & UCM) 116 Continuous

4

E-LITE-CNDT 1338 Lighting Conduit 134 Continuous

4

E-LITE-DUCT 1339 Lighting Ductbank 134 Continuous

4

E-LITE-TRAY 1340 Lighting Cable Tray / Wireway134 Continuous

4

Page 31: FLUOR – B & W Portsmouth, LLC On-Site Waste Disposal Facilityfbportsmouth.com/docs/Solicitations/ILTS-2014/1 - FBP OSWDF CADD... · FLUOR – B & W Portsmouth, LLC On-Site Waste

Page 31 of 397/24/2014

_______________________________________________________________MicroStation CADD Standards and Procedures

E-LTNG 1341 Lightning protection 47 Continuous

3

E-POWR 1342 Power (Cells & UCM) 47 Continuous

4

E-POWR-BUSW 1343 Power Busways 111 Continuous

4

E-POWR-CABL 1344 Power Cable 113 Continuous

4

E-POWR-CIRC 1345 Power Circuit113 Continuous

4

E-POWR-CNDT 1346 Power Conduit 111 Continuous

4

E-POWR-CNMB 1347 Power Circuit Number 0 Continuous

3

E-POWR-DUCT 1348 Power Ductbank 113 Continuous

4

E-POWR-EQPM 1349 Power panels, switchboards, transformers, etc. 117 Continuous

4

E-POWR-TRAY 1350 Power Cable Tray / Wireway 111 Continuous

4

E-SGNL-CNDT 1351 Digital Signal Conduit115 Continuous

4

E-SGNL-DUCT 1352 Digital Signal Ductbank 115 Continuous

4

E-SGNL-TRAY 1353 Digital Signal Cable Tray / Wireway 48 Continuous

4

E-SITE 1354 Site features 47 Continuous

4

E-SITE-OVHD 1355 Site features: overhead49 Continuous

4

E-SITE-POLE 1356 Site features: pole 53 Continuous

4

E-SITE-UGND 1357 Site features: underground48 Continuous

4

F-ANNO-DIMS 900 Dimensions 0 Continuous

3

F-ANNO-PATT 901 Patterning and hatching 6 Continuous

2

F-ANNO-SCHD 902 Schedules & tables 0 Continuous

3

F-ANNO-SYMB 903 Reference tags (section and detail callouts) 0 Continuous

3

F-ANNO-TEXT 904 Drawing text & annotations, notes, legends 0 Continuous

3

F-ANNO-TITL 905 Drawing or detail titles0 Continuous

3

F-DETL-BOLD 906 Bold lines 115 Continuous

4

F-DETL-CNTR 907 Center lines 3 Continuous

1

F-DETL-FINE 908 Fine lines 4 Continuous

2

F-DETL-HIDD 909 Hidden lines 0 Hidden2

2

F-DETL-MEDM 910 Medium lines 7 Continuous

3

F-PROT 911 Fire Protection48 Continuous

4

F-PROT-ALRM 912 Fire Protection: alarm 48 Continuous

4

F-PROT-EQPM 913 Fire Protection: equipment134 Continuous

4

F-PROT-EXTI 914 Fire Protection: extinguishers 116 Continuous

4

F-PROT-HOSE 915 Fire Protection: hoses 70 Continuous

4

F-PROT-HYDT 916 Fire Protection: hydrants and connections 70 Continuous

4

F-PROT-RATE 917 Fire Protection: ratings50 Continuous

4

F-PROT-SMOK 918 Fire Protection: smoke detector / heat sensors 116 Continuous

4

F-SPKL 919 Sprinkler system 48 Continuous

4

F-SPKL-CENT 920 Sprinkler system: center lines 0 Center2

2

F-SPKL-CLHD 921 Sprinkler system: pendent head (ceiling) 48 Continuous

4

F-SPKL-EQPM 922 Sprinkler system: equipment (hose racks, etc.) 70 Continuous

4

F-SPKL-OTHD 923 Sprinkler system: other heads11 Continuous

4

Page 32: FLUOR – B & W Portsmouth, LLC On-Site Waste Disposal Facilityfbportsmouth.com/docs/Solicitations/ILTS-2014/1 - FBP OSWDF CADD... · FLUOR – B & W Portsmouth, LLC On-Site Waste

Page 32 of 397/24/2014

_______________________________________________________________MicroStation CADD Standards and Procedures

F-SPKL-PIPE 924 Sprinkler system: piping / fittings 116 Continuous

4

G-ANNO-CONSULTANT General Consultant Block 0 Continuous

5

G-ANNO-LOGO 100 Company logo 0 Continuous

3

G-ANNO-MATC 101 Matchlines & battery limits 5 Phantom2

5

G-ANNO-MATC-TEXT 102 Matchline text0 Continuous

3

G-ANNO-NPLT 103 Non-plotted Info & construction lines (set to ""no plot"") 0 Continuous

3

G-ANNO-PROS 104 Date/Time/File name stamp 0 Continuous

3

G-ANNO-REVC 105 Revision Cloud 5 Continuous

5

G-ANNO-REVS 106 Revisions and revision triangles 0 Continuous

3

G-ANNO-SCOP 107 Scope boundary 11 Center2

4

G-ANNO-STMP 108 Professional Stamps0 Continuous

3

G-ANNO-STMP-ARCH 0 0

0

G-ANNO-STMP-CIV 0 0

0

G-ANNO-STMP-ELEC 0 0

0

G-ANNO-STMP-INST 0 0

0

G-ANNO-STMP-LAND 0 0

0

G-ANNO-STMP-MECH0 0

0

G-ANNO-STMP-STR 0 0

0

G-ANNO-SYMB 109 Reference tags (ie..section and detail callouts) 0 Continuous

3

G-ANNO-TABL 110 Tables & Schedules 0 Continuous

3

G-ANNO-TEXT 111 General text & notes, Title Block data 0 Continuous

2

G-ANNO-TEXT-BORDER Text In Border To Copy From 0 Continuous

0

G-ANNO-TITL 112 Drawing or detail titles0 Continuous

3

G-ANNO-TTLB 113 Title Block lines and Text, North Arrow 0 Continuous

3

G-ANNO-UNDEFINED 0 0

0

G-BARSCALE Bar Scale 1 0

1

G-DIMENSIONS Dimensions 0 0

1

G-HOLD 114 Hold cloud & text 112 Continuous

5

G-NORTH ARROW North Arrow1 0

1

G-PLAN 115 Key plan and associated hatch 7 Continuous

2

G-PLT-BDR border shape for plotting0 3

0

G-REFR 116 External reference files 0 Continuous

3

G-UNDEFINED 0 0

0

I-ANNO-DIMS 1400 Dimensions 0 Continuous

3

I-ANNO-PATT 1401 Patterning and hatching6 Continuous

2

I-ANNO-SCHD 1402 Schedules & tables 0 Continuous

3

I-ANNO-SYMB 1403 Reference tags (section and detail callouts) 7 Continuous

3

I-ANNO-TEXT 1404 Drawing text & annotations, notes, legends 0 Continuous

3

I-ANNO-TITL 1405 Drawing or detail titles 0 Continuous

3

I-DETL-BOLD 1406 Bold lines 115 Continuous

4

I-DETL-HIDD 1407 Hidden lines0 Hidden2

2

Page 33: FLUOR – B & W Portsmouth, LLC On-Site Waste Disposal Facilityfbportsmouth.com/docs/Solicitations/ILTS-2014/1 - FBP OSWDF CADD... · FLUOR – B & W Portsmouth, LLC On-Site Waste

Page 33 of 397/24/2014

_______________________________________________________________MicroStation CADD Standards and Procedures

I-DIAG-BOLD 1408 Diagrams: Bold lines 5 Continuous

5

I-DIAG-BOLD-HIDD 1409 Diagrams: Bold lines: hidden 5 Hidden2

5

I-DIAG-BOLD-PHAT 1410 Diagrams: Bold lines: phantom 117 Phantom2

5

I-DIAG-FINE 1411 Diagrams: Fine lines 4 Continuous

2

I-DIAG-FINI-HIDD 1412 Diagrams: Fine lines: hidden4 Hidden2

2

I-DIAG-FINI-PHAT 1413 Diagrams: Fine lines: phantom 4 Phantom2

2

I-DIAG-MEDM-1 1414 Diagrams: Medium lines -1 2 Continuous

2

I-DIAG-MEDM-2 1415 Diagrams: Medium lines -2 1 Continuous

4

I-DIAG-MEDM-HIDD 1416 Diagrams: Medium lines: hidden 2 Hidden2

2

I-DIAG-MEDM-PHAT 1417 Diagrams: Medium lines: phantom 7 Phantom2

3

I-INST 1418 Instrumentation52 Continuous

4

I-INST-CIRC 1419 Instrumentation: circuits 50 Continuous

4

I-INST-CLNG 1420 Instrumentation: ceiling 12 Continuous

4

I-INST-CNMB 1421 Instrumentation: circuit umber 0 Continuous

3

I-INST-EQPM 1422 Instrumentation: equipment 111 Continuous

4

I-INST-TEXT 1423 Instrumentation: text and tags 0 Continuous

3

I-INST-WALL 1424 Instrumentation: wall49 Continuous

4

I-PROC-CAPI 1425 Capilliary lines 54 0

3

I-PROC-ELEC 1426 Electrical I/O logic symbols 51 Continuous

3

I-PROC-ELEC-SGNL 1427 Electrical signal lines 51 Hidden2

3

I-PROC-HYDR 1428 Hydraulic lines 47 0

3

I-PROC-INST 1429 Instrumentation bubbles & instruments 7 Continuous

3

I-PROC-INST-SGNL 1430 Instrumentation signal lines7 Hidden2

3

I-PROC-MISC 1431 Flow arrows, misc 0 Continuous

3

I-PROC-SOFT 1432 Software lines 52 0

3

M-ANNO-DIMS 700 Dimensions 0 Continuous

3

M-ANNO-PATT 701 Patterning and hatching 6 Continuous

2

M-ANNO-SCHD 702 Schedules & tables 0 Continuous

3

M-ANNO-SYMB 703 Section lines and text7 Continuous

3

M-ANNO-TEXT 704 Drawing text & annotations, notes, legends 0 Continuous

3

M-ANNO-TITL 705 Drawing or detail titles 111 Continuous

4

M-CONT 706 Controls and instrumentation 7 Continuous

3

M-CONT-WIRE 707 Controls and instrumentation wiring 7 Continuous

3

M-DETL-BOLD 708 Bold lines 115 Continuous

4

M-DETL-CNTR 709 Center lines3 Center2

1

M-DETL-FINE 710 Fine lines 4 Continuous

2

M-DETL-HIDD 711 Hidden lines 0 Hidden2

2

M-DETL-MEDM 712 Medium lines 7 Continuous

3

M-FILT 713 Filter 1 Continuous

4

M-HUMI 714 Humidifier 1 Continuous

4

M-HVAC-EQPM 715 Equipment, AHU1 Continuous

4

Page 34: FLUOR – B & W Portsmouth, LLC On-Site Waste Disposal Facilityfbportsmouth.com/docs/Solicitations/ILTS-2014/1 - FBP OSWDF CADD... · FLUOR – B & W Portsmouth, LLC On-Site Waste

Page 34 of 397/24/2014

_______________________________________________________________MicroStation CADD Standards and Procedures

M-HVAC-EQPM-DEVC 716 Flow Measuring Devices 1 Continuous

4

M-HVAC-EXHS-CDFF 717 Exhaust - Grille, Register 50 Continuous

4

M-HVAC-EXHS-DEVC 718 Terminal Devices - Exhaust 1 Continuous

4

M-HVAC-EXHS-DUCT 719 Exhaust - Placed Fitting 114 Continuous

4

M-HVAC-EXHS-EQPM 720 Exhaust - Equipment1 Continuous

4

M-HVAC-EXHS-GRLL 721 Exhaust - Low Walls 50 Continuous

4

M-HVAC-EXHS-RFEQ 722 Exhaust - Rooftop equipment 50 Continuous

4

M-HVAC-ODCT 723 Other - Duct Surface 111 Continuous

4

M-HVAC-ODEV 724 Terminal Devices - Other 1 Continuous

4

M-HVAC-ODFF 725 Other - Diffuser, Grille, Register 47 Continuous

4

M-HVAC-ORHC 726 Reheat Coils - Other1 Continuous

4

M-HVAC-RDFF 727 Return - Grille, Register 52 Continuous

4

M-HVAC-RETN-DEVC 728 Terminal Devices - Return 1 Continuous

4

M-HVAC-RETN-DMPR 729 Dampers - Return / Exhaust 10 Continuous

5

M-HVAC-RETN-DUCT 730 Return - Duct Surface 116 Continuous

4

M-HVAC-RETN-GRLL 731 Return - Low Wall 52 Continuous

4

M-HVAC-SDFF 732 Supply - Diffuser, Grille, Register48 Continuous

4

M-HVAC-SPLY-DEVC 733 Terminal Devices - Supply 1 Continuous

4

M-HVAC-SPLY-DMPR 734 Dampers - Supply 10 Continuous

5

M-HVAC-SPLY-DUCT 735 Supply - Duct Surface 115 Continuous

4

M-HVAC-SPLY-EQPM 736 Supply - Equipment 1 Continuous

4

M-HVAC-SPLY-HEPA 737 Supply - HEPA Filters 48 Continuous

4

M-MISC 738 Miscellaneous Drawing Graphics9 Continuous

0

M-MKUP-CDFF 739 Make-Up - Diffuser, Grille, Register 47 Continuous

4

M-MKUP-DEVC 740 Terminal Devices - Make-up 1 Continuous

4

M-MKUP-DUCT 741 Make-Up - Duct Surface 111 Continuous

4

M-MKUP-EQPM 742 Make-Up equipment 1 Continuous

4

N-ANNO-DIMS 800 Dimensions 2 Continuous

2

N-ANNO-PATT 801 Patterning and hatching6 Continuous

2

N-ANNO-SCHD 802 Schedules & tables 0 Continuous

3

N-ANNO-SYMB 803 Reference tags (section and detail callouts) 7 Continuous

3

N-ANNO-TEXT 804 Drawing text & annotations, notes, legends 0 Continuous

3

N-ANNO-TITL 805 Drawing or detail titles 111 Continuous

4

N-BWDR 806 Biowaste drainage system 116 Continuous

4

N-DETL-BOLD 807 Bold lines115 Continuous

4

N-DETL-CNTR 808 Center lines 3 Center2

1

N-DETL-FINE 809 Fine lines 4 Continuous

2

N-DETL-HIDD 810 Hidden lines 0 Hidden2

2

N-DETL-MEDM 811 Medium lines 7 Continuous

3

N-DOMW 812 Domestic water system 111 Continuous

4

N-DOMW-CPIP 813 Domestic water system: cold water piping115 Continuous

4

Page 35: FLUOR – B & W Portsmouth, LLC On-Site Waste Disposal Facilityfbportsmouth.com/docs/Solicitations/ILTS-2014/1 - FBP OSWDF CADD... · FLUOR – B & W Portsmouth, LLC On-Site Waste

Page 35 of 397/24/2014

_______________________________________________________________MicroStation CADD Standards and Procedures

N-DOMW-EQPM 814 Domestic water system: equipment 115 Continuous

4

N-DOMW-HPIP 815 Domestic water system: hot water piping 102 Continuous

4

N-DOMW-RISR 816 Domestic water system: risers 115 Continuous

4

N-DOMW-TEXT 817 Domestic water system: text 0 Continuous

3

N-FIXT 818 Floor drains and fixtures52 Continuous

3

N-PROC 819 Process drainage system:113 Continuous

4

N-PROC-TEXT 820 Process drainage system: text 0 Continuous

3

N-SPRT 821 Supports 50 Continuous

3

N-SSWR 822 Sanitary sewer system: 116 Continuous

4

N-SSWR-EQPM 823 Sanitary sewer system: equipment 116 Continuous

4

N-SSWR-FIXT 824 Sanitary sewer system: fixtures52 Continuous

3

N-SSWR-FLDR 825 Sanitary sewer system: floor drains 116 Continuous

4

N-SSWR-TEXT 826 Sanitary sewer system: text 0 Continuous

3

N-SSWR-VENT 827 Sanitary sewer system: vents 11 Continuous

3

N-STRM 828 Storm drainage system: 117 Continuous

4

N-STRM-PIPE 829 Storm drainage system: piping 117 Continuous

4

N-STRM-RFDR 830 Storm drainage system: roof drains10 Continuous

4

N-STRM-TEXT 831 Storm drainage system: text 0 Continuous

3

N-STRM-VENT 832 Storm drainage system: vents 10 Continuous

3

P-ACID-PIPE 1100 Chemical/caustic/acid 53 Continuous

4

P-ACID-TEXT 1101 Chemical/caustic/acid: Text & annotations 0 Continuous

3

P-AIRV-PIPE 1102 Air/Gas/Vents 13 Continuous

4

P-AIRV-TEXT 1103 Air/Gas/Vents: Text & annotations0 Continuous

3

P-ANNO-DIMS 1104 Dimensions 2 Continuous

2

P-ANNO-PATT 1105 Patterning and hatching 6 Continuous

2

P-ANNO-SCHD 1106 Schedules & tables 0 Continuous

3

P-ANNO-SYMB 1107 Reference tags (section and detail callouts) 7 Continuous

3

P-ANNO-TEXT 1108 Drawing text & annotations, notes, legends 0 Continuous

3

P-ANNO-TITL 1109 Drawing or detail titles111 Continuous

4

P-CIP~-PIPE 1110 CIP 48 Continuous

4

P-CNDW-PIPE 1111 Condensate 50 Continuous

4

P-CNDW-TEXT 1112 Condensate: Text & annotations 50 Continuous

3

P-DETL-BOLD 1113 Bold lines 115 Continuous

4

P-DETL-CNTR 1114 Center lines 3 Center2

1

P-DETL-FINE 1115 Fine lines4 Continuous

2

P-DETL-HIDD 1116 Hidden lines 0 Hidden2

2

P-DETL-MEDM 1117 Medium lines 7 Continuous

3

P-FIRE-PIPE 1118 Fire Protection 48 Continuous

4

P-INSL 1119 Insulation Graphics 0 Hidden2

2

P-MISC-PIPE 1120 Miscellaneous 48 Continuous

4

P-PCWR-PIPE 1121 Water: return piping70 Continuous

3

Page 36: FLUOR – B & W Portsmouth, LLC On-Site Waste Disposal Facilityfbportsmouth.com/docs/Solicitations/ILTS-2014/1 - FBP OSWDF CADD... · FLUOR – B & W Portsmouth, LLC On-Site Waste

Page 36 of 397/24/2014

_______________________________________________________________MicroStation CADD Standards and Procedures

P-PCWS-PIPE 1122 Water: supply piping 47 Continuous

3

P-PCWS-TEXT 1123 Water: supply piping Text & annotations 52 Continuous

3

P-PROC-PIPE 1124 Process 52 Continuous

4

P-PWTR-PIPE 1125 Purified water 47 Continuous

4

P-SEWR-TEXT 1126 Sewers/Drains: Text & annotations0 Continuous

3

P-STEM-PIPE 1127 Steam 50 Continuous

4

P-STEM-TEXT 1128 Steam systems: Text & annotations 0 Continuous

3

P-SUPT 1129 Pipe Support 50 Continuous

3

P-WAST-PIPE 1130 Waste/Drains 48 Continuous

4

P-WATR-PIPE 1131 Water 47 Continuous

4

P-WATR-TEXT 1132 Water: Text & annotations0 Continuous

3

Q-ANNO-DIMS 1200 Dimensions 2 Continuous

2

Q-ANNO-PATT 1201 Patterning and Hatching6 Continuous

2

Q-ANNO-SCHD 1202 Schedules & tables 0 Continuous

3

Q-ANNO-SYMB 1203 Reference tags (section and detail callouts) 7 Continuous

3

Q-ANNO-TEXT 1204 Drawing text, notes & legends 0 Continuous

3

Q-ANNO-TITL 1205 Drawing or detail titles111 Continuous

4

Q-AREA 1206 Maintenance Area 116 Dashdot2

4

Q-CENT 1207 Center lines 0 Center2

2

Q-DETL-1 1237 Part 1: Object lines 48 Continuous

4

Q-DETL-2 1238 Part 2: Object lines 54 Continuous

4

Q-DETL-3 1239 Part 3: Object lines 52 Continuous

4

Q-DETL-4 1240 Part 4: Object lines11 Continuous

4

Q-DETL-5 1241 Part 5: Object lines 50 Continuous

4

Q-DETL-BOLD 1208 Bold lines 115 Continuous

4

Q-DETL-CNTR 1209 Center lines 0 Center2

2

Q-DETL-DASH-1 1242 Part 1: Dashed lines 0 Dashed2

2

Q-DETL-DASH-2 1243 Part 2: Dashed lines 6 Dashed2

2

Q-DETL-DASH-3 1244 Part 3: Dashed lines4 Dashed2

2

Q-DETL-DASH-4 1245 Part 4: Dashed lines 11 Dashed2

2

Q-DETL-DASH-5 1246 Part 5: Dashed lines 2 Dashed2

2

Q-DETL-FAST-1 1247 Part 1: Fasteners 51 Continuous

3

Q-DETL-FAST-2 1248 Part 2: Fasteners 54 Continuous

3

Q-DETL-FAST-3 1249 Part 3: Fasteners 52 Continuous

3

Q-DETL-FAST-4 1250 Part 4: Fasteners11 Continuous

3

Q-DETL-FAST-5 1251 Part 5: Fasteners 50 Continuous

3

Q-DETL-FINE 1210 Fine lines 0 Continuous

2

Q-DETL-HIDD 1211 Hidden lines 0 Hidden2

2

Q-DETL-HIDD-1 1252 Part 1: Hidden lines 51 Hidden2

3

Q-DETL-HIDD-2 1253 Part 2: Hidden lines 54 Hidden2

3

Q-DETL-HIDD-3 1254 Part 3: Hidden lines52 Hidden2

3

Page 37: FLUOR – B & W Portsmouth, LLC On-Site Waste Disposal Facilityfbportsmouth.com/docs/Solicitations/ILTS-2014/1 - FBP OSWDF CADD... · FLUOR – B & W Portsmouth, LLC On-Site Waste

Page 37 of 397/24/2014

_______________________________________________________________MicroStation CADD Standards and Procedures

Q-DETL-HIDD-4 1255 Part 4: Hidden lines 11 Hidden2

3

Q-DETL-HIDD-5 1256 Part 5: Hidden lines 50 Hidden2

3

Q-DETL-MEDM 1212 Medium lines 51 Continuous

3

Q-DETL-PATT-1 1257 Part 1: Hatch lines 3 Continuous

1

Q-DETL-PATT-2 1258 Part 2: Hatch lines6 Continuous

1

Q-DETL-PATT-3 1259 Part 3: Hatch lines 4 Continuous

1

Q-DETL-PATT-4 1260 Part 4: Hatch lines 11 Continuous

1

Q-DETL-PATT-5 1261 Part 5: Hatch lines 2 Continuous

1

Q-DETL-PHAT-1 1262 Part 1: Phantom lines 0 Phantom2

2

Q-DETL-PHAT-2 1263 Part 2: Phantom lines 6 Phantom2

2

Q-DETL-PHAT-3 1264 Part 3: Phantom lines4 Phantom2

2

Q-DETL-PHAT-4 1265 Part 4: Phantom lines 11 Phantom2

2

Q-DETL-PHAT-5 1266 Part 5: Phantom lines 2 Phantom2

2

Q-ELEV 1213 Elevation 54 Continuous

3

Q-ELEV-EQPM 1214 Elevation: equipment 102 Continuous

4

Q-ELEV-FIXT 1215 Elevation: fixtures 116 Continuous

4

Q-ELEV-GLAZ 1216 Elevation: glazing70 Continuous

3

Q-ELEV-HRDW 1217 Elevation: hardware 11 Continuous

3

Q-ELEV-OVHD 1218 Elevation: overhead 54 Continuous

4

Q-ELEV-PATT 1219 Elevation: texture and patterns 6 Continuous

1

Q-ELEV-STRC 1220 Elevation: Support structures 50 Continuous

4

Q-EQPM-1 1267 Equipment -1 50 Continuous

4

Q-EQPM-2 1268 Equipment -247 Continuous

4

Q-EQPM-3 1269 Equipment -3 47 Continuous

4

Q-EQPM-4 1270 Equipment -4 49 Continuous

4

Q-EQPM-5 1271 Equipment -5 49 Continuous

4

Q-EQPM-CART 1272 Equipment: Part containers/Carts/Rack, etc 2 Continuous

2

Q-EQPM-PART 1273 Equipment: Centerfuge Parts 1 Continuous

2

Q-EQPM-REFU 1274 Equipment: Refurbished12 Continuous

4

Q-EQPM-SAFE 1275 Equipment: Safety guarding/Fencing 51 Continuous

3

Q-EQPM-TOOL 1276 Equipment: Tooling 7 Continuous

2

Q-EQPM-WAST 1277 Equipment: Waste and recycling containers 1 Continuous

2

Q-EXHS 1221 Exhaust system 54 Continuous

3

Q-MAJQ 1222 Major equipment 10 Continuous

4

Q-MAJQ-BDRY 1223 Module Boundaries134 Center2

4

Q-MAJQ-CTRL 1224 Major equipment: control systems 111 Continuous

4

Q-MAJQ-DATA 1225 Major equipment: data/communications 116 Continuous

4

Q-MAJQ-FIRE 1226 Major equipment: fire/security 115 Continuous

4

Q-MAJQ-LITE 1227 Major equipment: electrical lighting 52 Continuous

4

Q-MAJQ-MISC 1228 Major equipment: miscellaneous 53 Continuous

4

Q-MAJQ-POWR 1229 Major equipment: electrical power114 Continuous

4

Page 38: FLUOR – B & W Portsmouth, LLC On-Site Waste Disposal Facilityfbportsmouth.com/docs/Solicitations/ILTS-2014/1 - FBP OSWDF CADD... · FLUOR – B & W Portsmouth, LLC On-Site Waste

Page 38 of 397/24/2014

_______________________________________________________________MicroStation CADD Standards and Procedures

Q-MAJQ-SUPT 1230 Major equipment:Supports 51 Continuous

3

Q-MINQ 1231 Minor equipment 47 Continuous

4

Q-POWR 1232 Power 47 Continuous

4

Q-SPCL 1233 Special equipment 53 Continuous

4

S-ANNO-DIMS 300 Dimensions0 Continuous

3

S-ANNO-PATT 301 Patterning and hatching 6 Continuous

2

S-ANNO-SYMB 302 Reference tags (ie..section and detail callouts) 7 Continuous

3

S-ANNO-TEXT 303 Drawing text & annotations, notes, legends 0 Continuous

3

S-ANNO-TITL 304 Drawing or detail titles 0 Continuous

3

S-BEAM-STEL 305 beams 114 Continuous

4

S-BRCG-STEL 306 bracing49 Continuous

3

S-COLS-STEL 307 building Column 116 Continuous

4

S-CONC-HIDD 308 Concrete Hidden lines 4 Hidden2

2

S-DETL-BOLD 309 Bold lines 115 Continuous

4

S-DETL-CNTR 310 Center lines 3 Center2

1

S-DETL-FINE 311 Fine lines 4 Continuous

2

S-DETL-HIDD 312 Hidden lines0 Hidden2

2

S-DETL-MEDM 313 Medium lines 7 Continuous

3

S-EMBD-CONC 314 Concrete Embedments 47 Continuous

3

S-FIRE-STEL 315 Fire proofing 9 Continuous

0

S-FNDN 316 Grade Beams, Walls, Equipment Saddles and Foundations 111 Continuous

4

S-FNDN-FTNG 317 Footings 54 Continuous

4

S-FNDN-PCAP 318 Pile caps54 Continuous

4

S-FNDN-PIER 319 Foundation - piers 114 Continuous

4

S-FNDN-PILE 320 Piles: Concrete or Steel 52 Continuous

4

S-FNDN-RBAR 321 Reinforcements 115 Continuous

4

S-GIRT 322 Girts and Purlins / Girt lines / Sag Rods 1 Continuous

4

S-HRAL 323 Handrail / Guardrail 0 Phantom2

3

S-PLAT 324 Structural platform4 Continuous

2

S-SLAB-CONC 325 cast-in-place concrete & curbs 53 Continuous

4

S-SLAB-DRAN 326 Drainage slope lines, Joints 9 Continuous

0

S-STRS 327 Stairs 4 Continuous

2

S-STRS-LADD 328 Ladders 4 Continuous

2

S-WALL-CMUW 329 CMU Walls 4 Continuous

2

V-BORE Existing Borings120 0

1

V-CABLE 0 0

0

V-CPT Existing Cone Penetrometer Tests 120 0

1

V-CULV Existing Culvert 120 0

1

V-FENCE-RAD Existing Rad Fence 120 bw

1

V-GAS 0 0

0

V-LEACHATE Existing Leachate Pipe120 6

1

Page 39: FLUOR – B & W Portsmouth, LLC On-Site Waste Disposal Facilityfbportsmouth.com/docs/Solicitations/ILTS-2014/1 - FBP OSWDF CADD... · FLUOR – B & W Portsmouth, LLC On-Site Waste

Page 39 of 397/24/2014

_______________________________________________________________MicroStation CADD Standards and Procedures

V-MHOLE Existing Manhole 120 0

1

V-MW Existing Monitoring Wells 120 0

1

V-PIEZ Existing Piezometers 120 0

1

V-SURV-MONU Existing Survey Monument 120 0

1

V-TEL0 0

0

V-VHOUSE Existing Valve House 120 0

1

V-WASTELIM Existing Limits of Waste 120 0

1