13
FMEA of CO 2 Air Conditioning Systems On SAE 2000 Automotive Alternative Refrigerant Systems Symposium July 11-13, 2000, Resort Suites Hotel, Scottsdale, AZ by Dr.-Ing. Ulrich Hussels RISA Sicherheitsanalysen GmbH, Germany e-mail: [email protected]

FMEA of CO Air Conditioning Systems - VIRUSX-Dz · FMEA of CO 2 Air Conditioning Systems On SAE 2000 Automotive Alternative Refrigerant Systems Symposium ... compressor with safety

Embed Size (px)

Citation preview

FMEA of CO2 Air ConditioningSystems

On SAE 2000 Automotive Alternative Refrigerant Systems SymposiumJuly 11-13, 2000, Resort Suites Hotel, Scottsdale, AZ

by Dr.-Ing. Ulrich HusselsRISA Sicherheitsanalysen GmbH, Germanye-mail: [email protected]

SAE 2000 Automotive Alternative Refrigerant Systems Symposium, July 11, 2000 2

The RISA Companyn Founded in 1990, situated in Berlin,

Germanyn 10 specialized engineers from research

institutes of the Technical University ofBerlin

n Working areas are safety analysis andsoftware development (databases)

n Customers from nuclear-, automotive-and LPG-industry

SAE 2000 Automotive Alternative Refrigerant Systems Symposium, July 11, 2000 3

Where this kind of Analysis is needed (examples):n Higher amount of energy in a small

amount of space (high energy density)n Nuclear Power Plants: reactor core

cooling, pressuren Automotive: velocity, pressuren LPG: great amount of inflammable and

explosive fluid/gas mixture

SAE 2000 Automotive Alternative Refrigerant Systems Symposium, July 11, 2000 4

Initiators and Core Teammembers

n Robert Mager, BMW AG (Chairman)n Jürgen Wertenbach, DaimlerChrysler AGn Baroto Adiprasito, Volkswagen AGn Ralf Köneke, Denso Automotive Deutschlandn Frank Obrist, Obrist Engineering

OBRIST__ENGINEERING__

SAE 2000 Automotive Alternative Refrigerant Systems Symposium, July 11, 2000 5

Aims of the analysis for aprototypical CO2 AC-Systemn Diagnosis of potential effects of failure eventsn Determination of countermeasuresn Proof of mastering all relevant effectsn Confirmation of the usability of CO2-

technology regarding to safety and productliability

n System-FMEA as a basis for a design-FMEA

SAE 2000 Automotive Alternative Refrigerant Systems Symposium, July 11, 2000 6

Form of the Analysis

n System-FMEA based on SAE J-1739n Additional classification for

consequences to human healthn Instructions to reduce the risk priority

number if it is greater than 108 to get abalanced risk level over all failureevents

SAE 2000 Automotive Alternative Refrigerant Systems Symposium, July 11, 2000 7

Risk Priority Number

RPN = Severity x Occurrence x Detection

Severity 1 - 10 (8 = Very High, 9 Hazardouswith warning)

Occurrence 1 - 10 (4 - 6 = Moderate)

Detection 1 - 10 (3 = High)

⇒ RPN 1 - 1000 (9 x 4 x 3 = 108, accordingto an engineering judgement )

SAE 2000 Automotive Alternative Refrigerant Systems Symposium, July 11, 2000 8

Table-Layout

Item Function

Potential

Failure

Mode

Potential

Effect(s) of

Failure

Sev

Cla

ss

Potential Cause(s)/

Mechanism(s) of

Failure

Occ

ur Current Design

Controls Det

ec

RP

N Recommended

Action(s)

Responsibility

(for the Rec-

ommended

Action)

Actions

Taken Sev

Occ

Det

RP

N

Com-

pressor

Transports

the medium;

Compresses

the medium

Loosening

of fasten-

ings

Refrigerant

pipe de-

taches, ex-

ternal leaks

9 B Material faults,

loosening of fas-

tenings

1 Quality control 2 18 Oscillation

tests

9 1 1 9

Gas

cooler

Conducts

heat to the

external

environment

Blockage

in refriger-

ant flow

Low cooling

capacity,

increase in

pressure

6 A Bends, blockages 2 Deformation

guard, layout;

design of com-

ponent

10 120 Parallel proce-

dures, pres-

sure sensor

switched in

front of the gas

cooler, plausi-

bility control

via regulation

control

6 2 6 72

SAE 2000 Automotive Alternative Refrigerant Systems Symposium, July 11, 2000 9

Scope of the Analysis

n 23 components within the system withn 107 failure events

in respect ton 3 operating modes,n 3 (+2) vehicle running modes andn 3 environment conditions

SAE 2000 Automotive Alternative Refrigerant Systems Symposium, July 11, 2000 10

PI-Diagram

hose linepiping

gas

cool

er

accumulator

expansion valve with safety system

evap

orat

or

internal heatexchanger

T

temperature sensor 1

filling socket

p

pressure sensor

savety valve HP

compressor with safety system and

auxiliary unit

savety valve LP

filling socket

HP high pressureLP low pressure

SAE 2000 Automotive Alternative Refrigerant Systems Symposium, July 11, 2000 11

Results

n An automotive CO2 AC-system is safe:n General rules for the arrangement of the

components have to be taken intoaccount

n Safety components and/or systemshave to be present

n Critical components are detected

SAE 2000 Automotive Alternative Refrigerant Systems Symposium, July 11, 2000 12

Outlook

n Development of common safety-standards for an automotive CO2 AC-system

n Systematic sampling of all failure eventsfrom existing prototype-systems

n Evaluation of specific failure rates duringthe operation of prototype system hours

n Performing a fault- and event treeanalysis

SAE 2000 Automotive Alternative Refrigerant Systems Symposium, July 11, 2000 13

Further Activities

n Further activities should be done to gaininternational acceptance