FILENAME BVM_Laser Ablation ICP-MS_August2016.indd INTERNAL REVISION 2
TRAP AT FINAL OUTPUT
CLIENT Acme Labs TRIM 17.0" x 11.0" CLIENT REVISION 2CREATION DATE 01/16/15 BLEED 17.25" x 11.25" (.125") OPERATOR RMHREVISION DATE August 29, 2016 12:37 PM FOLD 8.5" x 11.0" T: 604.417.7865
OUTPUT DATE 08/29/16 LIVE E: [email protected]
SAFE APPROVALS SEEN APPROVED
RESOLUTION 300dpi CREATIVE --FONTS -- COPYWRITER --
NOTES ACCOUNT KMPROOFREAD --
C M Y K
Bureau Veritas MineralsLaser Ablation ICP-MS AnalysisFor Lithogeochemistry & Mineral Specific Chemistry
MINERALS
BVM_Laser Ablation ICP-MS_August2016.indd 1 8/29/2016 12:39:52 PM
FILENAME BVM_Laser Ablation ICP-MS_August2016.indd INTERNAL REVISION 2
TRAP AT FINAL OUTPUT
CLIENT Acme Labs TRIM 17.0" x 11.0" CLIENT REVISION 2CREATION DATE 01/16/15 BLEED 17.25" x 11.25" (.125") OPERATOR RMHREVISION DATE August 29, 2016 12:37 PM FOLD 8.5" x 11.0" T: 604.417.7865
OUTPUT DATE 08/29/16 LIVE E: [email protected]
SAFE APPROVALS SEEN APPROVED
RESOLUTION 300dpi CREATIVE --FONTS -- COPYWRITER --
NOTES ACCOUNT KMPROOFREAD --
FILENAME BVM_Laser Ablation ICP-MS_August2016.indd INTERNAL REVISION 2
TRAP AT FINAL OUTPUT
CLIENT Acme Labs TRIM 17.0" x 11.0" CLIENT REVISION 2CREATION DATE 01/16/15 BLEED 17.25" x 11.25" (.125") OPERATOR RMHREVISION DATE August 29, 2016 12:37 PM FOLD 8.5" x 11.0" T: 604.417.7865
OUTPUT DATE 08/29/16 LIVE E: [email protected]
SAFE APPROVALS SEEN APPROVED
RESOLUTION 300dpi CREATIVE --FONTS -- COPYWRITER --
NOTES ACCOUNT KMPROOFREAD --
C M Y K
Lithogeochemistry & Mineral Specific Chemistry
www.bureauveritas.com/um
Bureau Veritas Laser Ablation ICP-MS analysis is designed to meet a broad range of analytical requirements with a single cost effective method. In Lithogeochemistry Mode LA-ICP-MS capitilises on BV’s high productivity robotic fusion technology with state of the art laser ablation and ICP-MS instruments to provide a fully extracted quantitative analysis for all elements. Detection limits are comparable to industry leading mixed acid trace element ICP-MS packages.
n Total analysis at trace and ultra tracedetection limits equivalent to mixedacid ICP-MS packages.
n Simplifies the analysis process toa single, cost effective fusion.
n XRF and ICP-MS capabilities canbe combined to extend the dynamicrange in one analysis (eg. U from10ppb to % level.
n Minimises hazards and waste due toelimination of corrosive acids.
LA-ICP-MS BENEFITS
n Spot analyses can be conducted onselect mineral grains for full chemicalanalysis or over a given area to providequantitative false colour element maps.Grain mount or thin section options areavailable.
Epidote Au
Mineral Specific Chemistry Mode
BVM_Laser Ablation ICP-MS_August2016.indd 2 8/29/2016 12:39:55 PM
FILENAME BVM_Laser Ablation ICP-MS_August2016.indd INTERNAL REVISION 2
TRAP AT FINAL OUTPUT
CLIENT Acme Labs TRIM 17.0" x 11.0" CLIENT REVISION 2CREATION DATE 01/16/15 BLEED 17.25" x 11.25" (.125") OPERATOR RMHREVISION DATE August 29, 2016 12:37 PM FOLD 8.5" x 11.0" T: 604.417.7865
OUTPUT DATE 08/29/16 LIVE E: [email protected]
SAFE APPROVALS SEEN APPROVED
RESOLUTION 300dpi CREATIVE --FONTS -- COPYWRITER --
NOTES ACCOUNT KMPROOFREAD --
C M Y K
Bureau Veritas provide leading testing and inspection services for the global commodities industry
Traditional multi element lithogeochemistry analysis packages require a number of different digestion methods and instruments in order to achieve optimum results.
Alternatively, when XRF is included with LA-ICP-MS into a combined package, only a single Li-borate fusion is digestion is required. This method will provide major elements from XRF, trace and minor elements from LA-ICP-MS.
Elements Available (Detection limits in ppm)
XRF
Al (100)K (100)S (10) Zr (10)
As (10)Mg (100)Si (100)
Ba (10)Mn (10)Ti (100)
Ca (100)Na** (100)U (10)
Cr (10)Ni (10)W (10)
Cu (10)P (10)Y (10)
Fe (100)Pb (10)Zn (10)
LA-ICP-MS
Ag (0.1)Ce (0.02)Eu (0.01)Lu (0.01)Pr (0.01)Sn (0.2)Tl (0.2)Zn (5)
As (0.2)Co (0.1)Ga (0.1)Mn (1)Rb (0.05)Sr (0.1)Tm (0.01)Zr (0.5)
Ba (0.5)Cr (1)Gd (0.01)Mo (0.2)Re (0.01)Ta (0.01)U (0.01)
Be (0.2)Cs (0.01)Hf (0.01)Nb (0.01)Sb (0.1)Tb (0.01)V (0.1)
Bi (0.02)Cu (2)Ho (0.01)Nd (0.01)Sc (0.1)Te (0.2)W (0.05)
Br (10)Dy (0.01)In (0.05)Ni (2)Se (5*)Th (0.01)Y (0.02)
Cd (0.1)Er (0.01)La (0.01)Pb (1)Sm (0.01)Ti (1)Yb (0.01)
* partially volatilized** may not be available for some sample types
SAMPLEPREP WEIGHING FUSION
DIGESTICP-AESICP-MS
Trace | Minor Elements (Total)
FUSEDBEAD XRF
Minor Elements Major Oxides
(Total)
ACID DIGEST ICP-AESICP-MS
Trace Elements (Partial)
SAMPLEPREP WEIGHING
XRFFUSEDBEAD
Trace Elements Minor Elements
Major Oxides (Total)LA-ICP-MS
BVM_Laser Ablation ICP-MS_August2016.indd 3 8/29/2016 12:39:57 PM
© C
opyr
ight
Bur
eau
Verit
as M
iner
als
- 202
1
NORTH AMERICA
CANADAMain ceVANCOUVER Tel: +1 604 253 3158Toll Free: +1 800 990 2263 [email protected]
Metallurgical Division RICHMOND Tel: +1 604 272 8110 [email protected]
TIMMINS Tel: +1 705 360 5232
WHITEHORSE Tel: +1 867 393 4725
USAELKO Tel: +1 775 777 1438
FAIRBANKS Tel: +1 775 303 8896
JUNEAU Tel: +1 907 750 1734
RENO-SPARKS Tel: +1 775 359 6311
MEXICOCABORCA Tel: +52 637 372 65 21
DURANGO Tel: +52 618 810 39 74
HERMOSILLO Tel: +52 662 2603057
CENTRAL AMERICA
NICARAGUA MANAGUA CITYTel: +505 22522 135
CARIBBEAN
DOMINICAN REPUBLIC MAIMONTel: +809 551 2011
SOUTH AMERICA
ARGENTINAMAIPU, MENDOZATel: +54 261 524 0456/7
PERITO MORENOTel: +54 11 663 26402
CHILESANTIAGOTel: +56 2 3502100
COQUIMBOTel: +52 2 23502100
ECUADORQUITO Tel: +593 2 282 9407
PERULIMA & AREQUIPA Tel: +51 1 613 8080
EUROPE
POLANDKRAKOWTel: +48 601 306 201
TURKEYANKARA Tel: +90 312 866 3466/3539
AFRICA
IVORY COASTABIDJANTel: +22 52 35 35 323
MALIBAMAKO Tel: +22 37 64 29 914
SOUTH AFRICA PRETORIATel: +27 12 94 00 911
PACIFIC
AUSTRALIAADELAIDETel: +61 8 8440 7100
CARDIFFTel: +61 2 4902 4858
KALGOORLIETel: +61 8 9021 7155
PERTHTel: +61 8 6218 5700
WHYALLATel: +61 8 8647 6500
MINERALSFor more information contact:[email protected] | www.bureauveritas.com/um