CARCINOGENICITY
EPA—“B1” Probable human carcinogen
ACGIH—“A2” Suspected human carcinogen
WHO (IARC)—“Group 1” Carcinogenic to humans
PHYSICAL SYMPTOMS
1-10 ppm—Eye irritation; lacrimation at 4 ppm
10-20 ppm—Coughing, heart palpitations, tight feeling in chest
50-100 ppm and above—Pulmonary edema, pneumonitis, death
Contact with skin (formalin or HCHO-containing resins)—Dermatitis
Male single oral ingestion 517 mg/kg (DHHS)
Minimum Fatal Dose Level —
OCCUPATIONAL EXPOSURE STANDARDS
ACGIH TLV®
0.3 ppm (Ceiling)
OSHA PEL
0.75 ppm (TWA)2 ppm (Ceiling)
NIOSH REL
0.016 ppm (TWA)0.1 ppm (Ceiling)
Method 2016 most sensitive
Silica gel/2,4-dinitrophenylhydrazine
Method 2541
Sorbent tube/2-hydroxymethyl piperidine
(1,8-dihydroxynaphthalene-3,6-disulfonic acid)
Impinger/chromotropic acid
Method 3500
INSTRUMENT METHODS—PRACTICAL AND OTHERWISE
FTIR
Semi-automated wet chemical methods
Electrochemical (converted alcohol detectors)
Interscan purpose-designed HCHO sensor
ADVANTAGES
Good sensitivity
0-500 parts-per-billion full scale measuring range available
Excellent specificity
Little effect from alcohols
Full interference info on gasdetection.com website
Quick response time
Rise time to 50%
Rise time to 90% 30-45 seconds
5-10 seconds
APPLICATIONS
HCHO ubiquitous in the workplace, however…
Biggest applications have been in the forest products industry
e.g., monitoring of emissions from manufactured wood products
Interscan’s HCHO sensor is the heart of Georgia Pacific’s
DYNAMIC MICROCHAMBER
Board compliance testing time reduced from 2 weeks to less than an hour
For Survey Applications,We Recommend Our Nomad Data Logger
16-bit resolution
Models available for voltage and 4-20mA inputs
Self-contained units also available for temperature, humidity and pH
Sampling rate adjustable—1 second to 10 hours in 1 second intervals
Storage capacity—522,240 readings
Excellent software included
CONCLUDING REMARKS
We've covered the health effects and occupational standards for formaldehyde
We've looked at wet chemical and instrumental methods for formaldehyde
We've seen a special application of Interscan's HCHO sensor