10
LED Line 1 ft 1100 lm 3R HV3 May 2016 Datasheet Key features and benefits • State-of-the-art LED module efficiency of up to 165 lm/W • Long life-time: >50,000 hours • High color rendering (CRI >80 and >90) • Excellent color consistency of 3 SDCM • Choice of color temperatures (3000 K, 4000 K and 5000 K) • Two lumen packages: 650 lm and 1100 lm per foot/280 mm • LED module range with 1, 2 or 3 rows of LEDs • Tunable lumen output, efficacy and lifetime • Push-in connectors enabling automated wiring • Five year system warranty Fortimo LED Line systems are designed to produce pure white light for general lighting applications with high efficiency levels. The Fortimo LED Line portfolio consists of 3 main ranges of products, which have been differentiated by the number of rows of LEDs contained on the module. Fortimo LED Linear encompasses a wide range, offering solutions for all the different types of linear luminaires. Fortimo LED Line Gen3 Retail Office Industry Suitable for:

Fortimo LED Line Gen3 - Philips · 2016. 11. 13. · 3 - 10 Datasheet - Fortimo LED Line 1 ft 1100 lm 3R HV3 May 2016 180° 30° 30° 60° 60° 90° 90° 120° 120° 100 200 300 400

  • Upload
    others

  • View
    3

  • Download
    0

Embed Size (px)

Citation preview

Page 1: Fortimo LED Line Gen3 - Philips · 2016. 11. 13. · 3 - 10 Datasheet - Fortimo LED Line 1 ft 1100 lm 3R HV3 May 2016 180° 30° 30° 60° 60° 90° 90° 120° 120° 100 200 300 400

LED Line 1 ft 1100 lm 3R HV3

May 2016

Datasheet

Key features and benefits• State-of-the-art LED module efficiency of up to 165 lm/W• Long life-time: >50,000 hours• High color rendering (CRI >80 and >90)• Excellent color consistency of 3 SDCM• Choice of color temperatures (3000 K, 4000 K and 5000 K)• Two lumen packages: 650 lm and 1100 lm per foot/280 mm• LED module range with 1, 2 or 3 rows of LEDs• Tunable lumen output, efficacy and lifetime• Push-in connectors enabling automated wiring• Five year system warranty

Fortimo LED Line systems are designed to produce pure white light for general lighting applications with high efficiency levels. The Fortimo LED Line portfolio consists of 3 main ranges of products, which have been differentiated by the number of rows of LEDs contained on the module. Fortimo LED Linear encompasses a wide range, offering solutions for all the different types of linear luminaires.

Fortimo LED Line Gen3

Retail O�ce Industry

Suitable for:

Page 2: Fortimo LED Line Gen3 - Philips · 2016. 11. 13. · 3 - 10 Datasheet - Fortimo LED Line 1 ft 1100 lm 3R HV3 May 2016 180° 30° 30° 60° 60° 90° 90° 120° 120° 100 200 300 400

2 - 10 Datasheet - Fortimo LED Line 1 ft 1100 lm 3R HV3 May 2016

Ordering data

Commercial product name EOC 12NC Box quantity

Fortimo LED Line 1ft 1100lm 830 3R HV3 8718696 413555 00 9290 009 22206 180

Fortimo LED Line 1ft 1100lm 840 3R HV3 8718696 413517 00 9290 009 22306 180

Fortimo LED Line 1ft 1100lm 850 3R HV3 8718696 413579 00 9290 009 22406 180

Drive currents and case temperatures

Parameter Nominal* Life** Max*** Unit

I (current through the LED module) 228 450 450 mA

Tc (case temperature at Tc point) 40 80 80 °C

* Nominal value at which typical performance is specified.** Value at which lifetime L70B50 ≥ 50,000 hour is specified.*** Maximum value for safe operation; do not operate above this value.

Optical characteristics - table per color (CCT)

Fortimo LED Line 1 ft 1100 lm 830 3R HV3Parameter Min Typ Max Unit

Correlated color temperature (CCT) 3000 K

Color coordinates (CIEx, CIEy)* (0.432, 0.401) -

CRI** 80 -

Radiation angle 120 deg

Color consistency of 3 SDCM, averaged over the module. R9 of 4, typical value.

Rel

ativ

e in

tens

ity

(a.u

)

Wavelength (nm)

1

0.8

0.6

0.4

0.2

0380 430 480 530 580 630 680 730 780

830

Operation point 830 lm lm/W

80% I-nom 183 mA Tc 25 °C 858 162

Tc-nom 40 °C 841 160

Tc-life 80 °C 786 155

I-nom 228 mA Tc 25 °C 1067 157

Tc-nom 40 °C 1046 156

Tc-life 80 °C 978 151

I-life 450 mA Tc 25 °C 2035 138

Tc-nom 40 °C 1996 137

Tc-life 80 °C 1867 132

Tolerance for flux data is ±7.5%.Tolerance for efficacy data is ±10%.

Fortimo LED Line 1 ft 1100 lm 840 3R HV3Parameter Min Typ Max Unit

Correlated color temperature (CCT) 4000 K

Color coordinates (CIEx, CIEy)* (0.383, 0.379) -

CRI** 80 -

Radiation angle 120 deg

Color consistency of 3 SDCM, averaged over the module. R9 of 15, typical value.

Rel

ativ

e in

tens

ity

(a.u

)

Wavelength (nm)

1

0.8

0.6

0.4

0.2

0380 430 480 530 580 630 680 730 780

840

Operation point 840 lm lm/W

80% I-nom 183 mA Tc 25 °C 902 170

Tc-nom 40 °C 884 169

Tc-life 80 °C 826 163

I-nom 228 mA Tc 25 °C 1122 165

Tc-nom 40 °C 1100 164

Tc-life 80 °C 1029 158

I-life 450 mA Tc 25 °C 2141 146

Tc-nom 40 °C 2099 144

Tc-life 80 °C 1964 139

Tolerance for flux data is ±7.5%.Tolerance for efficacy data is ±10%.

Page 3: Fortimo LED Line Gen3 - Philips · 2016. 11. 13. · 3 - 10 Datasheet - Fortimo LED Line 1 ft 1100 lm 3R HV3 May 2016 180° 30° 30° 60° 60° 90° 90° 120° 120° 100 200 300 400

3 - 10 Datasheet - Fortimo LED Line 1 ft 1100 lm 3R HV3 May 2016

180°

30°30°

60°60°

90°90°

120°120°

100

200

300

400

(cd/1000 lm 0° L.O.R.= 1.00

0-180° 90-270°

Beam shape

The Philips LED module generates a Lambertian beam shape, which is a pragmatic starting point for OEMs wishing to design secondary optics.

Electrical characteristics

Parameter Min Typ Max Unit

Nominal current 228 mA

Forward voltage 28 29.4 31.4 V

Power consumption 6.4 6.7 7.2 W

Energy efficiency label A++

Minimum dimming for performance 10 %

Number of modules per chain 8

Bins 2 (C and D)

Specifications stated at Tc-nom and I-nom.

Fortimo LED Line 1 ft 1100 lm 850 3R HV3Parameter Min Typ Max Unit

Correlated color temperature (CCT) 5000 K

Color coordinates (CIEx, CIEy)* (0.345, 0.355) -

CRI** 80 -

Radiation angle 120 deg

Color consistency of 3 SDCM, averaged over the module.

Rel

ativ

e in

tens

ity

(a.u

)

Wavelength (nm)

1

0.8

0.6

0.4

0.2

0380 430 480 530 580 630 680 730 780

850

Operation point 850 lm lm/W

80% I-nom 183 mA Tc 25 °C 902 170

Tc-nom 40 °C 884 169

Tc-life 80 °C 826 163

I-nom 228 mA Tc 25 °C 1122 165

Tc-nom 40 °C 1100 164

Tc-life 80 °C 1029 158

I-life 450 mA Tc 25 °C 2141 146

Tc-nom 40 °C 2099 144

Tc-life 80 °C 1964 139

Tolerance for flux data is ±7.5%.Tolerance for efficacy data is ±10%.

Measurement tolerance is ± 5% for the flux data and 6% for the efficacy data.* Measurement tolerance is ± 0.005** Measurement tolerance is ± 1.5

Page 4: Fortimo LED Line Gen3 - Philips · 2016. 11. 13. · 3 - 10 Datasheet - Fortimo LED Line 1 ft 1100 lm 3R HV3 May 2016 180° 30° 30° 60° 60° 90° 90° 120° 120° 100 200 300 400

4 - 10 Datasheet - Fortimo LED Line 1 ft 1100 lm 3R HV3 May 2016

Performance over life

Lumen maintenanceOperation point Time x 1000 hours L70 L80 L90

B50 B20 B10 B50 B20 B10 B50 B20 B10

80% I-nom 183 mA Tc 25 °C >70 >70 >70 >70 >70 >70 36 35 35

Tc-nom 40 °C >70 >70 >70 68 66 65 32 31 31

Tc-life 80 °C >70 70 69 45 44 43 21 21 20

I-nom 228 mA Tc 25 °C >70 >70 >70 >70 >70 >70 36 35 35

Tc-nom 40 °C >70 >70 >70 68 66 65 32 31 31

Tc-life 80 °C >70 70 69 45 44 43 21 21 20

I-life 450 mA Tc 25 °C >70 >70 >70 66 64 63 31 30 30

Tc-nom 40 °C >70 >70 >70 58 56 56 27 27 26

Tc-life 80 °C 61 60 59 38 37 37 18 18 17

Values in the table are based on available LM80 LED data (12,000h). Lumen maintenance will be updated once additional measurement data becomes available.

Parameter Min Typ Max Unit

Δu'v' at 6000 hours 0.007 -

Specifications stated while Tc < Tc-life and I < I-life.

Absolute maximum ratings

Parameter Min Typ Max Unit

Current through the LED module (I-max) 450 mA

Case temperature (Tc-max) 80 °C

Power rated at U-max and I-max 16.2 W

ESD (direct contact) 8 kV

ESD (air) 15 kV

Working voltage (between input to metal mounting plate) 420 Vdc

Voltage strength (Input to metal mounting plate) 1840 Vac

Ambient temperature -40 °C

Wiring

Specification item Value Unit Condition

Input wire cross-section 0.2…0.75 mm2 Solid

18…24 AWG

0.3..0.5 mm2 Stranded

20..22 AWG

Input wire strip length 7.5..8.5 mm

Tested cable length 4000 mm Total length of wiring including LED modules,

one way

Connector suited for robot wiring.

Page 5: Fortimo LED Line Gen3 - Philips · 2016. 11. 13. · 3 - 10 Datasheet - Fortimo LED Line 1 ft 1100 lm 3R HV3 May 2016 180° 30° 30° 60° 60° 90° 90° 120° 120° 100 200 300 400

5 - 10 Datasheet - Fortimo LED Line 1 ft 1100 lm 3R HV3 May 2016

Mechanical characteristics

Parameter Min Typ Max Unit

Length 279.5 280 280.5 mm

Width 54.5 55 55.5 mm

Height excl. connector 2 2.1 2.2 mm

Height incl. connector 5.6 5.8 6 mm

Warpage (IPC-TM-650) 4 %

Bow & Twist of the PCB after production tested and released according IPC-TM-650 2.4.22.

ININ

OUTOUT

4055

20

7649 8026

26

280

Ø4

.75

1.5

5.9

9

1.6

5

4.2

4

0.9

7.75

A (2:1)

A

Connector, suited for robot wiringPolarity sensitive

Hole allows wire feed through

Connector, suited for robot wiringPolarity sensitive

Approbation andconformity marks

Area suited for clamping (4x)

Module speci�cinfo sticker Tc point

Screw hole (4x)max. M4 screw size

ININ

OUTOUT

Page 6: Fortimo LED Line Gen3 - Philips · 2016. 11. 13. · 3 - 10 Datasheet - Fortimo LED Line 1 ft 1100 lm 3R HV3 May 2016 180° 30° 30° 60° 60° 90° 90° 120° 120° 100 200 300 400

6 - 10 Datasheet - Fortimo LED Line 1 ft 1100 lm 3R HV3 May 2016

Application information

Compliance and approvalIEC / EN 62031, IEC / EN 62471

Photobiological safetyRisk group: Risk group 1

EnvironmentalRoHS / REACH

Application informationZhaga

Designation of the Book-7 LLE category L28W6

Luminous Flux category C011

CCT category 3000 K, 4000 K, 5000 K

CRI 80

The position of the temperature measurement point tp Same as Tc point

The value of tp,max 40

IP rating No IP rating

Overheating protection No protection

Luminaire class IEC Class I or Class II

Thermal switching table

Calculated number of switches at which the survival rate of the population ≥90%, at a given ambient temperature and delta T with repect to Tc (where Tc = Tambient + delta T)

Tambient [°C]

-40 -30 -20 -10 0 10 20 30 40 50 60 70

de

lta

T [°

C]

(de

lta

T =

Tc -

Tam

bie

nt)

10

Co

nti

nu

ou

s o

pe

rati

on

or

dim

min

g o

nly

>100 k >100 k >100 k >100 k >100 k >100 k >100 k >100 k >100 k >100 k >100 k

20 >100 k >100 k >100 k >100 k >100 k >100 k >100 k >100 k >100 k >100 k X

30 >100 k >100 k >100 k >100 k >100 k >100 k >100 k >100 k >100 k X X

40 45 k 45 k 45 k 45 k 45 k 45 k 45 k 45 k X X X

50 20 k 20 k 20 k 20 k 20 k 20 k 20 k X X X X

60 10 k 10 k 10 k 10 k 10 k 10 k X X X X X

70 5 k 5 k 5 k 5 k 5 k X X X X X X

80 3 k 3 k 3 k 3 k X X X X X X X

90 2 k 2 k 2 k X X X X X X X X

100 1 k 1 k X X X X X X X X X

Page 7: Fortimo LED Line Gen3 - Philips · 2016. 11. 13. · 3 - 10 Datasheet - Fortimo LED Line 1 ft 1100 lm 3R HV3 May 2016 180° 30° 30° 60° 60° 90° 90° 120° 120° 100 200 300 400

7 - 10 Datasheet - Fortimo LED Line 1 ft 1100 lm 3R HV3 May 2016

Flux and efficacy versus currentI [mA] Flux [%] Efficacy [%]

(I-nom x 50%) 115 51% 107%

140 62% 105%

170 75% 104%

200 88% 102%

(I-nom) 228 100% 100%

260 114% 98%

290 126% 96%

320 139% 95%

350 151% 93%

380 163% 91%

410 175% 90%

(I-life) 450 191% 88%

Flux and efficacy versus temperature at TcTc [°C] Flux [%] Efficacy [%]

(Tc-life) 80 94% 97%

75 94% 97%

70 95% 98%

(Tc-nom) 40 100% 100%

25 102% 101%

0 105% 102%

Tuning information

0 10 20 30 40 50 60 70 80 90 100

Tc (°C)

110%

105%

100%

95%

90%

85%

80%

75%

Valu

e re

lati

ve t

o n

om

inal

(%

)

E�cacy (%)Flux (%)

0 50 100 150 200 250 300 350 400 450 500

Single LED module current (mA)

200%

180%

160%

140%

120%

100%

80%

60%

40%

20%

0%

Rel

ativ

e nu

mb

er

E�cacy (%)Flux (%)

Page 8: Fortimo LED Line Gen3 - Philips · 2016. 11. 13. · 3 - 10 Datasheet - Fortimo LED Line 1 ft 1100 lm 3R HV3 May 2016 180° 30° 30° 60° 60° 90° 90° 120° 120° 100 200 300 400

8 - 10 Datasheet - Fortimo LED Line 1 ft 1100 lm 3R HV3 May 2016

Lumen maintenance

0% 100%

0% 100%

70%

0 10,000 20,000 30,000 40,000 50,000 70,000 60,000

Operating lifetime (hours)

Lum

en m

aint

enan

ce (

%) Lum

en dep

reciation (%

)

B50B10

0% 100%

0% 100%

70%

0 10,000 20,000 30,000 40,000 50,000 70,000 60,000

Operating lifetime (hours)

Lum

en m

aint

enan

ce (

%) Lum

en dep

reciation (%

)

Tc 25 °CTc nom 40 °CTc-life 80 °C

Lumen maintenance at I-life and Tc-life conditions

Lumen maintenance for B50 at current I-life conditions

Lumen depreciation as a function of operating hours for I-life and Tc-life.

Lumen depreciation as a function of operating hours at different Tc values and I-life.

Page 9: Fortimo LED Line Gen3 - Philips · 2016. 11. 13. · 3 - 10 Datasheet - Fortimo LED Line 1 ft 1100 lm 3R HV3 May 2016 180° 30° 30° 60° 60° 90° 90° 120° 120° 100 200 300 400

9 - 10 Datasheet - Fortimo LED Line 1 ft 1100 lm 3R HV3 May 2016

Wiring schematic

More information in the design-in guide of LED Linear modules.

Rset

Rset

Rset

HV system1 chain (1C)

HV system1 chain (1C)

HV system2 chain (2C)

Chain 1 di�erent lenghtas Chain 2 = NOK

Idrive = Inom

Vdrive = Vf x # boards

Idrive = Inom

Vdrive = Vf x # boards

Idrive = Inom x #C

Vdrive = (Vf x # boards) / #C

Non-Isolated LED driver 1 ft HV LED board

HV LED board HV LED board

HV LED board HV LED board

HV LED board HV LED board

1 ft HV LED board 1 ft HV LED board 1 ft HV LED board

Datasheet 8/17/18

Return End

Return End

Return End

Return End

+-

Non-Isolated LED driver+-

Non-Isolated LED driver+-

Examples

Page 10: Fortimo LED Line Gen3 - Philips · 2016. 11. 13. · 3 - 10 Datasheet - Fortimo LED Line 1 ft 1100 lm 3R HV3 May 2016 180° 30° 30° 60° 60° 90° 90° 120° 120° 100 200 300 400

© Philips Lighting Holding B.V. 2016. All rights reserved. Philips reserves the right to make changes in specifications and/or to discontinue any product at any time without notice or obligation and will not be liable for any consequences resulting from the use of this publication.

05/2016 Data subject to change

www.philips.com/technology www.philips.com/fortimo www.philips.com/xitanium