20
product line - a junction box FOUNDATION FIELDBUS PROFIBUS PA Junction BOX

FOUNDATION FIELDBUS PROFIBUS PA - Sense

  • Upload
    others

  • View
    5

  • Download
    0

Embed Size (px)

Citation preview

Page 1: FOUNDATION FIELDBUS PROFIBUS PA - Sense

product line - a junction box

FOUNDATION FIELDBUSPROFIBUS PA

Junction BOX

Page 2: FOUNDATION FIELDBUS PROFIBUS PA - Sense

2 Sense

IntroductionThis catalog contains information about the Profibus PA and Foundation Fieldbus network and has the main goal to show thejunction box line for the field instrument. The junction box in this catalog can be passive, with protection against short-circuit orintrinsic safety barrier to protection for up to 8 Ex I field equipment and are available in plastic or metallic material.

Profibus PA and Foundation Fieldbus H1With fieldbus technology, users can have several benefits offered by digital technology and also they can take advantage and getoptimization and cost savings with the network distribution bringing safety and reliability in the operations. For the success of any automation and control network, the installation should be done carefully and within the specifications.Precautions and practices are required when designing, installing or testing Profibus PA networks and also adopted for theFoundation Fiedbus H1 network, since the physical layer of these protocols are defined by the same international standardIEC61158-2.

The Profibus PA and Foundation Fieldbus H1 protocol is a bi-directional digital communication that allows the networkinterconnection of several equipment in the field, doing acquisition execution and functions, as well as the procedures andmonitoring stations (IHMs) through supervisor softwares. The protocol is based on OSI standard, which has the following layers:Physical Layer, Communication Stack and User Application. We can mention the management in a global way with the applicationsand advent models based on Function Blocks and Device Descriptions, which recently was standardized according to IEC, the EDDL concept including HART, Foundation Fieldbus and Profibus. The Physical Layer is defined by international standards (IEC, ISA). It receives messages from the Communication Stack andconverts them into physical signals in the middle of the fieldbus transmission including and removing preambles, delimiters ofbeginning and end of messages.

The physical layer is based on the IEC61158-2, we can cite the following features:

• Data transfer using Manchester code with transmission rate 31.25Kbit / s

• For a full signal communication, each product must have at least 9 volts. The H1 physical layer allows that the fieldequipment is powered by bus. The same pair of wires that feed the equipment also provides the communication signal.

• Maximum length is 1900m (trunk and spurs) without repeaters.

• Using up to 4 repeaters, the maximum length can be 9.5 km.

• Non safety buses in Profibus PA and no external power for trunk line can support the communication of 2 to 32connected field equipment.

• Profibus PA trunk must be able to support various equipments in accordance with intrinsic safety standards and withoutexternal power: - Explosion Group IIC: 9 equipments - Explosion Group IIB: 23 equipments Note: It can connect more equipments than the specified, depending on the equipment consumption, the power supply, the intrinsic safety barrier characteristics and the FISCO model.

• No interrupting trunk line in operation while connection and disconnection equipments on the spurs.

• Topology: bus, tree, star or mixed (a combination of all supported technologies).

The FISCO model has the following features:

a) a single active element (power supply) on the Fieldbus, located in non-classified area; b) the others equipments are in classified area; c) each field equipment must have minimum consumption of 10mA; d) in Ex ia areas the maximum bus length must be 1000m and 1000m in Ex ib areas; e) For the cable (no cabling restriction until 1000) must take the following parameters:- R´:15 ... 150 Ohm/Km- L´: 0.4 ... 1 mH/Km- C´: 80 ... 200 nF/KmCable type A: 0.8mm2(AWG18) (*)

f) Termination:a. R = 90 ... 100 ohmsb. C = 0 ... 2.2 µF.

Physical Layer

Page 3: FOUNDATION FIELDBUS PROFIBUS PA - Sense

3Sense

The FISCO concept was optimized allowing a greater number of the field equipments, according to the bus length, taking intoaccount the cable variation parameters (R, ‘L’, C ‘) and using terminators. The concept is in accordance with gases categories andgroups that make a simple evaluation of the complete installation involving intrinsic safety. This increased the current capability per segment and the evaluation for users became easier. Furthermore, when purchasing certified products they don't have to worry with calculations, even changing them in operation.

15 a 20mA p-p

Fieldbus Device

Devi

ce C

urr

ent

H1 - 31.25 Kbit/s Voltage Mode

Receiving Transmitting0.75 a 1.0V p-p

Voltage

PowerSupply

C

100 Ohm

C

100 Ohm

Fieldbus Network

Terminator

C is sized to pass 31.25Kbit/s

0 1 1 0 0+

0

1

-

1 Bit Time

CLOCK

DATA

MANCHESTERBIPHASE-LENCODING

Fieldbus signal in voltage mode Manchester code

The data transmission of a field equipment is typically 10mA in 31.25Kbit / s at an equivalent resistive load of 50 Ohms creating amodulated voltage signal in 1.0 Volt peak to peak. The power supply can provide 9 to 32 VDC, but in secure applications (IS) it´snecessary to follow the intrinsic safety barriers requirements.

PHYSICAL LAYER

USERAPPLICATION

COMMUNICATION“STACK”

v

tFieldbus Media

(wire)

The total cable length is the sum of the trunk length (bus master) and all the Spurs (larger than 1m) which the maximum length ofthe cable type A (*) is the 1900m in unsafe areas. In safe areas the maximum length is 1000 m using cable type A and the spurscannot exceed 30m.

31.25 Kbit/s Voltage mode

Page 4: FOUNDATION FIELDBUS PROFIBUS PA - Sense

4 Sense

TopologyWe can have the following topologies below, remembering that these examples are for Profibus PA Network, but for H1 Networkthey also apply to the Foundation Fieldbus: star, line and point-to-point. Normally, in practice is used a mixed topology:

15 a 20mA p-p

Fieldbus Device

Devi

ce C

urr

ent

H1 - 31.25 Kbit/s Voltage Mode

Receiving Transmitting0.75 a 1.0V p-p

Voltage

PowerSupply

C

100 Ohm

C

100 Ohm

Fieldbus Network

Terminator

C is sized to pass 31.25Kbit/s

0 1 1 0 0+

0

1

-

1 Bit Time

CLOCK

DATA

MANCHESTERBIPHASE-LENCODING

PHYSICAL LAYER

USERAPPLICATION

COMMUNICATION“STACK”

v

tFieldbus Media

(wire)

Network CablesSeveral cable types can be used (it is recommended to use the twisted-pair with the shield). The maximum length can changedepending on the diameter and others cable components. Below we show four cable types, but there are more options. No specialcable type is required. Usually the cables that connect the instruments can be used for the trunk line. The network cable forProfibus PA and Foundation Fieldbus are produced by several manufacturers becoming easy the choice.

Star Line Point-to-point

Cable options

Pair Diameter Max. length(m) Type

single 0.75mm2 1900 A

mult 0.32mm2 1200 B

mult 0.13mm2 400 C

mult 1.25mm2 200 D

- Zo @ 31,25KHz = 100 Ohm ± 20%- Max. Attenuation @ 39KHz = 3dB/ Km- Max.capacitance unbalance to earth = 2 nF/ Km- Max. DC resistance per conductor = 22 W/ Km- Max. propagation delay change 7.8 - 39KHz = 1.7 ms/ Km- Conductor transversal area: 0.75mm

2.

Cable Type A

Note: only the shield must be grounded, never the communication wires. If the cable has no shielding wire, it should be inside ametal conduit that works as a shield.

A spur is a branch off the trunk and can vary in length between 1 and 120m. Spurs length is basically independent of the cable typeand the total length can´t not exceeded the specifications, but depends on the amount of equipment connected in it. Never connect more than four devices on the spurs. The spurs are used to connect the equipments to the trunk so they can be removed withoutinterrupting the network operation.

Spurs

Number ofSpurs

amount of the equipments

1 equipment

2 equipments

3 equipments

4 equipaments

25 - 32 1 m 1 m 1 m 1 m

19 - 24 30 m 1 m 1 m 1 m

15 - 18 60 m 30 m 1 m 1 m

13 - 14 90 m 60 m 30 m 1 m

1 - 12 120 m 90 m 60 m 30 m

Equipment x Spur lengthThe maximum segment length is the sum of the trunks and spurs lengths and the lengths less than 1 m are not considered spurs.The amount of spurs and the number of equipment should be in accordance with the table below.

Note 1: For Ex installations you should not exceed the 9 equipments in group IIC and the lengthshould be up to 30m with one equipment per spur and the consumption less than 110 mA.Note 2: It is important to pay attention to the spur length when using the star topology, sincethe Spurs in this case are often longer when compared with the bus line topology.

TerminadorThe terminator is designed tomatch the network impedance and for this must be installed onall edges of trunk line, so thereflection effect will beeliminated and the networkworks normally.

Page 5: FOUNDATION FIELDBUS PROFIBUS PA - Sense

5Sense

FD - Passive Junction Box - General Purpose

Provide a simple and secure way the distribution of the points for the network of up to four equipments. The case is plastic material and has internal terminal forconnecting the spurs allowing the field installation with protection against liquidpenetration (IP66). The input and output network is connected in a dual plug-in connector, allowingthe distributor board disconnection without interrupting the rest of the network,being de-energized only their spurs.

Junction box for general purpose

Network Points General Purpose

Profibus PA2 PA-MD-2D

4 PA-MD-4D

Foundation Fieldbus2 FF-MD-2D

4 FF-MD-4D

2 or 4 points available

General purpose module, plastic house

Internal network terminator

Passive junction box only for spurs of thenetwork trunk line

sn

oisn

emi

D laci

na

hce

M

Module internal view

8080

57

,55

7,5

2626 160160

2424

Provide a simple and secure way the distribution points for a network of up to eight equipments. The case is in plastic or metal material with terminals forspur connections allowing the field installation with protection against liquidpenetration (IP66).The input and output network connector is a dual plug-in, allowing thedistributor board disconnection without interrupting the rest of the network,being de-energized only their spurs.

4, 6 or 8 points available

Passive junction box only for spurs.

General purpose in plastic or metallic case

Junction box for general purpose

Network FD4 FD6 FD8

Profibus PAPlastic general

purpose

PA-FD-4D PA-FD-6D PA-FD-8D

Metallic PA-FDM-4D PA-FDM-6D PA-FDM-8D

FoundationFieldbus

Plastic generalpurpose

FF-FD-4D FF-FD-6D FF-FD-8D

Metallic FF-FDM-4D FF-FDM-6D FF-FDM-8D

MD - Passive Junction Box - General Purpose

:et

oN

noisr

ev rotc

en

noc r

of el

bali

ava

osla w

eiv la

nret

ni el

ud

oM

Page 6: FOUNDATION FIELDBUS PROFIBUS PA - Sense

6 Sense

Specifications

Features PROFIBUS PAPlastic Metallic

FOUNDATION FIELDBUSPlastic Metallic

2 points MD model PA-MD-2D FF-MD-2D

4 points MD model PA-MD-4D FF-MD-4D

4 points FD model PA-FD-4D PA-FDM-4D FF-FD-4D FF-FDM-4D

6 points FD model PA-FD-6D PA-FDM-6D FF-FD-6D FF-FDM-6D

8 points FD model PA-FD-8D PA-FDM-8D FF-FD-8D FF-FDM-8D

Signaling power no no

Short electronic protection for spurs no no

Terminator yes yes

Terminator signaling no no

Ex protection - -

Fault monitoring - -

Network connection 3 ways double plug-in terminal 2.5 mm² 3 ways double plug-in terminal 2.5 mm²

Cable type Profibus PA cable Foundation Fieldbus cable

Input/Output for trunk cable cable gland PG16 cable gland PG16

Cable disconnection allowed without interrupting the rest of the network allowed without interrupting the rest of the network

Number of spurs 2, 4, 6 or 8 2, 4, 6 or 8

Spur connections 3 ways plug-in terminal 2.5 mm² 3 ways plug-in terminal 2.5 mm²

Housing material Plastic (MD and FD) aluminum (FDM) Plastic (MD and FD) aluminum (FDM)

Mounting cover 4 screws with rubber gasket 4 screws with rubber gasket

Protection class IP 66 IP 66

Operation temperature -20°C to +55°C -20°C to +55°C

Weight Approx. 1600g Approx. 1600g

Accessories included terminal, isolator tube, cover, cable gland terminal, isolator tube, cover, cable gland

Mechanical Dimensions

8 points

Dimensions - FD

FDA

(mm)B

(mm)C

(mm)

Plastic 200 120 57,5

Metallic 200 120 65

Topology

PLC

Fieldbus or

Profibus PA

Segment ProtectorGeneral Purpose

Segment ProtectorGeneral Purpose

* Dimensions for 4, 6 and 8 pointsmodels.

Page 7: FOUNDATION FIELDBUS PROFIBUS PA - Sense

7Sense

Segment Protectors are fieldbus distributor which incorporate electronic protectionagainst short-circuit for each network segment and its spurs. They are available with 2or 4 points of derivations and mounted in plastic box. All versions are mounted with cable gland and double plug-in connector for the trunk line connection and plug-in connectors for the derivations (Spurs).

Segment Protector for general purpose

Network PointsGeneralPurpose

Profibus PA2 PA-MD-2P

4 PA-MD-4P

Foundation Fieldbus2 FF-MD-2P

4 FF-MD-4P

4 or 6 points available general purpose in plastic house

Network terminator inside themodule

Protection against short-circuit

sn

oisn

emi

D laci

na

hce

M

Module internal view

8080

57

,55

7,5

2626 160160

2424

MD - Segment Protector - General Purpose

FD - Segment Protector - general purpose

:et

oN

noisr

ev rotc

en

noc r

of el

bali

ava

osla

Electronic Protection and Network terminatorThe network modules for Profibus PA and Foundation Fieldbus haveelectronic protection against short circuit in each spur. FF and PA modules also incorporate the network terminator and to enable it turn on a dipswitch located inside the module.

Segment Protectors are fieldbus distributor which incorporate electronic

protection against short-circuit and overload for each spur. They are available

with 4, 6 or 8 derivation points and can be mounted in plastic or metal box.They

have double plug-in connector for trunk line connection and plug-in connectors for

the derivations (Spurs). All versions are mounted with cable glands.

Electronic Protection and Network terminatorThe network modules for Profibus PA and Foundation Fieldbus have ElectronicProtection against short-circuit in each spurs. FF and PA modules also incorporate the network terminator for switching it onlyturn on the dipswitch located inside the module.

weiv l

anr

etni

elu

do

M

Segment Protector general purpose

Rede FD4 FD6 FD8

Profibus PAPlastic general

purpose

PA-FD-4P PA-FD-6P PA-FD-8P

Metallic PA-FDM-4P PA-FDM-6P PA-FDM-8P

FoundationFieldbus

Plastic generalpurpose

FF-FD-4P FF-FD-6P FF-FD-8P

Metallic FF-FDM-4P FF-FDM-6P FF-FDM-8P

Page 8: FOUNDATION FIELDBUS PROFIBUS PA - Sense

8 Sense

Specifications

Mechanical Dimensions

Protector 8 points

Tabela de Dimensões - FD

FDA

(mm)B

(mm)C

(mm)

Plastic 200 120 57.5

Metallic 200 120 65

Topology

* Dimensions for 4 and 6 pointsmodels.

Features PROFIBUS PA FOUNDATION FIELDBUS

House Plastic Metallic Plastic Metallic

MD 2 points model PA-MD-2P FF-MD-2P

MD 4 points model PA-MD-4P FF-MD-4P

FD 4 points model PA-FD-4P PA-FDM-4P FF-FDM-4P FF-FDM-4P

FD 6 points model PA-FD-6P PA-FDM-6P FF-FDM-6P FF-FDM-6P

FD 8 points model PA-FD-8P PA-FDM-8P FF-FDM-8P FF-FDM-8P

Power supply 9 to 32 Vdc 9 to 32 Vdc

Current per channel 40 mA ± 5% 40 mA ± 5%

Internal signaling red led red led

Electronic Protection for short-circuitin spurs

yes yes

Terminator yes yes

Terminator signaling no no

Ex protection - -

Consumption without load fieldbus distributor: 2points: < 12mA / 4 points: < 18mA / 6 points: < 25mA / 8 points: < 38mA

Fault monitoring Red Led blinking : short-circuit in the spurs

Network connection double 3 ways plug-in terminal 2.5 mm² double 3 ways plug-in terminal 2.5 mm²

Cable type Profibus PA cable Foundation Fieldbus cable

Input/Output for trunk cable cable gland PG16 cable gland PG16

cable desconnexion allowed without interrupting the rest of the network allowed without interrupting the rest of the network

Number of spurs 2, 4, 6 or 8 2, 4, 6 or 8

Spur connections 3 ways plug-in terminal 2.5 mm² 3 ways plug-in terminal 2.5 mm²

Housing material Plastic (MD e FD) aluminum (FDM) Plastic (MD e FD) aluminum (FDM)

Mounting cover 4 screws with rubber gasket 4 screws with rubber gasket

Protection class IP 66 IP 66

Operation temperature -20°C to +55°C -20°C to +55°C

Weight Aprox. 1600g Aprox. 1600g

Accessories included terminal, isolator tube, cover, cable gland terminal, isolator tube, cover, cable gland

Page 9: FOUNDATION FIELDBUS PROFIBUS PA - Sense

9Sense

Segment Protectors are fieldbus distributors which incorporate electronic protectionagainst short-circuit for each network segment and its spurs. They are available with 2or 4 points of derivations and are mounted in a plastic box. All versions are mounted with cable glands, double plug-in connector for trunk lineconnection and plug-in connectors for the derivations (Spurs).

Segment Protector Ex e

Network PointsGeneralPurpose

Profibus PA2 PA-MD-2P-Exe

4 PA-MD-4P-Exe

Foundation Fieldbus2 FF-MD-2P-Exe

4 FF-MD-4P-Exe

4 or 6 points available Ex e model in plastic house

Switchable integrated Networkterminator

Short-circuit protection

sn

oisn

emi

D laci

na

hce

M

Module internal view

1

2

3

4

MD - Segment Protector Increased Safety Ex e

FD - Segment Protector Increased Safety Ex e

:et

oN

noisr

ev rotc

en

noc r

of el

bali

ava

osla

Electronic Protection and Network terminatorThe network modules for Profibus PA and Foundation Fieldbus haveElectronic Protection against short-circuit in each spurs. FF and PA modules also incorporate the network terminator for switching itonly turn on the dip switch located inside the module.

Segment Protectors are fieldbus distributors which incorporate electronic

protection against short-circuit for each network segment and its spurs. They are

available with 4, 6 or 8 derivation points and can be mounted in a plastic or metal

box. All models are mounted with cable glands, double plug-in connector for the

trunk line cable and plug-in connectors for the derivations (Spurs).

Electronic Protection and Network terminatorThe network modules for Profibus PA and Foundation Fieldbus have ElectronicProtection against short-circuit in the spurs. FF and PA modules also incorporate the network terminator for switching it turns on the dip switch located inside the module.

weiv l

anr

etni

elu

do

M

Segment Protector Ex e

Network FD4 FD6 FD8

Profibus PAPlastic

Ex ePA-FD-4P-Exe PA-FD-6P-Exe PA-FD-8P-Exe

Metallic PA-FDM-4P-Exe PA-FDM-6P-Exe PA-FDM-8P-Exe

FoundationFieldbus

PlasticEx e

FF-FD-4P-Exe FF-FD-6P-Exe FF-FD-8P-Exe

Metallic FF-FDM-4P-Exe FF-FDM-6P-Exe FF-FDM-8P-Exe

Page 10: FOUNDATION FIELDBUS PROFIBUS PA - Sense

10 Sense

Specifications

PROFIBUS PAPlastic Metallic

FOUNDATION FIELDBUSPlastic Metallic

MD 2 points model PA-MD-2P-Exe - FF-MD-2P-Exe -

MD 4 points model PA-MD-4P-Exe - FF-MD-4P-Exe -

FD 4 points model PA-FD-4P-Exe PA-FDM-4P-Exe FF-FD-4P-Exe FF-FDM-4P-Exe

FD 6 points model PA-FD-6P-Exe PA-FDM-6P-Exe FF-FD-6P-Exe FF-FDM-6P-Exe

FD 8 points model PA-FD-8P-Exe PA-FDM-8P-Exe FF-FD-8P-Exe FF-FDM-8P-Exe

Power supply 9 to 32 Vdc 9 to 32 Vdc

Current per channel 40 mA ± 5% 40 mA ± 5%

Internal indicator red led red led

Short Electronic Protection in thespurs

yes yes

Terminator yes yes

Terminator signaling não não

Ex protection Ex e Ex e

Consumption without load fieldbus distributor 2 points: < 12mA / 4 points: < 18mA / 6 points: < 25mA / 8 points: < 38mA

Fault monitoring Red led blinking: short-circuit in the spurs

Network connection double 3 ways plug-in terminal 2.5 mm² double 3 ways plug-in terminal 2.5 mm²

Cable type Profibus PA cable Foundation Fieldbus cable

Input/Output for trunk cable cable gland PG16 cable gland PG16

Cable desconnexion allowed without interrupting the rest of the network allowed without interrupting the rest of the network

Number of spurs 2, 4, 6 or 8 2, 4, 6 or 8

Spur connections 3 ways plug-in terminal 2.5 mm² 3 ways plug-in terminal 2.5 mm²

Housing material Plastic (MD e FD) aluminum (FD) Plastic (MD e FD) aluminum (FD)

Mounting cover 4 screws with rubber gasket 4 screws with rubber gasket

Protection class IP 66 IP 66

Operation temperature -20°C to +55°C -20°C to +55°C

Weight Aprox. 1600g Aprox. 1600g

Accessories included terminal, isolator tube, cover, cable gland terminal, isolator tube, cover, cable gland

Mechanical Dimensions

Protector 8 points

Tabela de Dimensões - FD

FDA

(mm)B

(mm)C

(mm)

Plastic 200 120 91

Metallic 200 120 65

Topology

PLC

Fieldbus or

Profibus PA

Segment Protector Ex e

Segment Protector Ex e

* Dimensions for 4 and 6 pointsmodels.

Page 11: FOUNDATION FIELDBUS PROFIBUS PA - Sense

11Sense

MD - Passive Derivator Ex iProvide in a simple and secure way the network equipment connection of up tofour points using a plastic box with internal terminal connections to spurs thatallows the installation in field with protection against liquid penetration (IP66). The input and output connector of the trunk line is a double plug-in connectorallowing the distributor board disconnection without interrupting the rest of thenetwork, being de-energized only their spurs.

Intrinsic safety modules

Network Spur points Modules Ex i

Profibus PA2 PA-MD-2D-Exi

4 PA-MD-4D-Exi

Foundation Fieldbus2 FF-MD-2D-Exi

4 FF-MD-4D-Exi

4 or 6 points available

Intrinsic safety modules in plastic house

Internal network terminator

Derivators for hazardous areas

FD - Passive Derivators Ex i

Module internal view

Provide in a simply and secure way the network equipment connection of up to eight equipments, using a plastic or metallic box with internal connectionterminals to spurs allowing the installation in field with protection against liquid penetration (IP66). The input and output connector of the trunk line is a double plug-in connectorallowing the distributor board disconnection without interrupting the rest of the Network being only their spurs de-energized.

4, 6 or 8 points available

Passive derivators only for spurs.

Intrinsic safety module in plastic or metallic house

weiv l

anr

etni

elu

do

M

Intrinsic safety modules

Network FD4 FD6 FD8

Profibus PAPlastic

Ex iPA-FD-4D-Exi PA-FD-6D-Exi PA-FD-8D-Exi

Metallic PA-FDM-4D-Exi PA-FDM-6D-Exi PA-FDM-8D-Exi

FoundationFieldbus

PlasticEx i

FF-FD-4D-Exi FF-FD-6D-Exi FF-FD-8D-Exi

Metallic FF-FDM-4D-Exi FF-FDM-6D-Exi FF-FDM-8D-Exi

sn

oisn

emi

D laci

na

hce

M

8080

57

,55

7,5

2626 160160

2424

:et

oN

noisr

ev rotc

en

noc r

of el

bali

ava

osla

Page 12: FOUNDATION FIELDBUS PROFIBUS PA - Sense

12 Sense

Specifications

PROFIBUS PAPlastic Metallic

FOUNDATION FIELDBUSPlastic Metallic

Modelos MD 2 points PA-MD-2D-Exi - FF-MD-2D-Exi -

Modelos MD 4 points PA-MD-4D-Exi - FF-MD-4D-Exi -

FD 4 points model PA-FDM-4D-Exi PA-FDM-4D-Exi FF-FD-4D-Exi FF-FDM-4D-Exi

FD 6 points model PA-FDM-6D-Exi PA-FDM-6D-Exi FF-FD-6D-Exi FF-FDM-6D-Exi

FD 8 points model PA-FDM-8D-Exi PA-FDM-8D-Exi FF-FD-8D-Exi FF-FDM-8D-Exi

Function junction box for network junction box for network

Power supply indicator no no

Short Electronic Protection in thespurs

no no

Terminator yes yes

Terminator signaling no no

Ex protection Ex i Ex i

Fault monitoring - -

Network connection 3 ways double plug-in terminal 2.5 mm² 3 ways double plug-in terminal 2.5 mm²

Cable type PA cable Fieldbus cable

Input/Output for trunk cable cable gland PG16 cable gland PG16

cable desconnexion allowed without interrupting the rest of the network allowed without interrupting the rest of the network

Number of spurs 2, 4, 6 or 8 2, 4, 6 or 8

Spur connections 3 ways plug-in terminal 2.5 mm² 3 ways plug-in terminal 2.5 mm²

Housing material Plastic (MD e FD) aluminum (FD) Plastic (MD e FD) aluminum (FD)

Mounting cover 4 screws with rubber gasket 4 screws with rubber gasket

Protection class IP 66 IP 66

Operation temperature -20°C to +55°C -20°C to +55°C

Weight Aprox. 1600g Aprox. 1600g

Accessories included terminal, isolator tube, cover, cable gland terminal, isolator tube, cover, cable gland

Mechanical Dimensions

8 points

2255

C

A

B

Tabela de Dimensões - FD

FDA

(mm)B

(mm)C

(mm)

Plastic 200 120 91

Metallic 200 120 65

Topology

Ex i field equipments

Ex i

SDCD

Fieldbus or

Ex i

Profibus PA

Ex i Derivator

ExiBarrier

Ex i Ex i

Ex i Derivator

Ex i field equipments

* dimension for 4 and 6 pointsmodels.

Page 13: FOUNDATION FIELDBUS PROFIBUS PA - Sense

13Sense

Field Instruments Ex i

Ex i

Barrier Ex i

PLC

Fieldbus or

Trunk line Ex e

Ex i

Profibus PA

Intrinsic Safety Spurs( Ex i)

Field Instruments Ex i

Ex i Ex i

Barrier Ex i

It´s a fieldbus distributor that integrates an intrinsic safety barrier foreach individual output (Spur), providing the signaling and communication signal to each field instrument connected in the spur. Manufactured with high technology the field barrier allows theequipments disconnection in the spurs with the bus line energized. Available for Profibus PA and Foundation Fieldbus the barrierincorporates an intrinsical safe protection to each individual spuravailable in 2, 4, 6 or 8 points of derivations.

Field Barrier Exi

Total Security Módulos MD Módulos FD

The power sent to the field instrument is limited by the intrinsic safety barrier thatprovides a smart protection against short-circuit that turns off the output when thefault is detected and maintained the spur output current to a minimum value nocontributing to the communication collapse in the trunk line due to the high currentconsumption.

7

12

40

I (mA)

t (s)Short-Circuit

Sense field barrier

* Device connected to spur with 12mA current consumption

7

12

40

I (mA)

t (s)Short-Circuit

Product offer in the market

FeaturesConnectivity with safety and practicality

Available in Plastic or Metallic materialwith 2, 4, 6 or 8 points

One barrier required for each derivationpoint (spur).

Modules certified for intrinsic safety

Used in explosive atmospheres, zones 1and 2

Fieldbus distributors (network andspurs) in all models

Intrinsic Safety DefinitionsThe intrinsic safety definition is a representative prevention concept of the ignition by power limiting of the incoming bus supply aswell as installation components in the field. The working principle is based on manipulating and storing electric low-power incapable of producing a detonation of the explosiveatmosphere due to heating effects or electrical sparks. In general it can be applied to several equipments and instrumentation systems, and the electric power only can be controlled atlow levels in instruments such as electronic current transmitters, pneumatic converters, limit switches, signaling, etc. The basicprinciple of the intrinsic safety is handle and storage low energy, so the circuit installed in the safe area never has enough energyrated (manipulated or stored) capable of causing ignition in the potentially explosive atmosphere. The great advantage of intrinsicsafety is to allow the instruments disconnection even energized.

Topology in Safe Network (Ex i)

Page 14: FOUNDATION FIELDBUS PROFIBUS PA - Sense

14 Sense

MD - Field Barrier ExiThe MD field barrier is fieldbus distributor which incorporates an intrinsicsafety barrier for each spur. It´s available with 2 points of derivation in aplastic house.The input and output connector of the line trunk is a double plug-in terminal block, allowing the distributor board disconnection without interrupting therest of the network being only their spurs de-energized (spurs).

Module internal view

Allow the exchange of field equipment with the network working.

Terminator

ne

two

rl p

lug

-in

te

rmin

al

spur plug-interminal

Intrinsic Safety Barrier

Network Modelo

Profibus PA PA-MD-2B-Exei

Foundation Fieldbus FF-MD-2B-Exei

Mechanical Dimensions

8282

60

60

2626 160160

2424

1

IN

OUT

2

SpecificationsPROFIBUS PA FOUNDATION FIELDBUS

Function Intrinsic Safety Intrinsic Safety

Operating voltage 16 to 35 Vcc 16 to 35 Vcc

Consumption without load 16V - < 37mA / 35V - < 30mA 16V - < 37mA / 35V - < 30mA

Protection reverse polarity and short-circuit I < 20mA reverse polarity and short-circuit I < 20mA

Voltage output 13,6V / 1% - without load, 13.4 to 13.8 and<10V to 40mA 13,6V / 1% - without load, 13.4 to 13.8 and<10V to 40mA

Max. current per output 40mA 40mA

Led signaling led verde: Power supply / vermelho piscando: curto-circuito na saída

Electronic Protection nos seg. yes yes

Fault monitoring Red led blinking: short-circuit in the spurs

Ex protection Ex i (a barrier for each segment) Ex i (a barrier for each segment)

Terminator yes yes

Terminating indicator no no

Network connection 3 ways double plug-in terminal 3 ways double plug-in terminal

Cable type Profibus PA cable Foundation Fieldbus cable

Input/Output of the main cable by cable gland PG16 by cable gland PG16

cable disconnection allowed without interrupting the rest of the network allowed without interrupting the rest of the network

Number of the spurs 2 points 2 points

Spur connections bornes plug-in 3 vias bornes plug-in 3 vias

Housing material Plastic Plastic

Mounting cover 4 screws with rubber gasket 4 screws with rubber gasket

Protection class IP 66 IP 66

Operation temperature -20ºC to +55ºC -20ºC to +55ºC

Accessories included terminals, isolator tube, cover, cable gland terminals, isolator tube, cover, cable gland

Page 15: FOUNDATION FIELDBUS PROFIBUS PA - Sense

15Sense

FD - Field Barriers Exi

The FD Field Barrier is a Fieldbus

distribution module that

integrates an intrinsic safety

barrier for each spur. It´s

available with 4, 6 or 8 points for

the spurs in a plastic or metallic

box. The input and output

network (trunk) is connected in a

double plug-in connector that

allows the distributor board dis-

connection without interrupting

the rest of the network, and being

turns off only in their derivations

(spurs).

Module FD4 Module FD6 Module FD8

Network FD4B FD6B FD8B

Profibus PAPlastic Ex i PA-FD-4B-Exei PA-FD-6B-Exei PA-FD-8B-Exei

Metallic Ex i PA-FDM-4B-Exei PA-FDM-6B-Exei PA-FDM-8B-Exei

FieldbusPlastic Ex i FF-FD-4B-Exei FF-FD-6B-Exei FF-FD-8B-Exei

Metallic Ex i FF-FDM-4B-Exei FF-FDM-6B-Exei FF-FDM-8B-Exei

Terminator

Network plug-in terminal

Pression terminal for the Spurs

Protection of the network terminal in Increased Safety

Allow the exchange of field equipment with the network energized.

Spur Status Led

(blink in short-circuit)

Ground terminal

Spur Status Led

(blink in short-circuit)

weiv l

anr

etni

elu

do

M

Page 16: FOUNDATION FIELDBUS PROFIBUS PA - Sense

16 Sense

Features PROFIBUS PA FOUNDATION FIELDBUS

Modelo 4 points PA-FDM-4B-Exei FF-FDM-4B-Exei

Modelo 6 points PA-FDM-6B-Exei FF-FDM-6B-Exei

Modelo 8 points PA-FDM-8B-Exei FF-FDM-8B-Exei

Function Intrinsic Safety Intrinsic Safety

Operating voltage 16 to 35 Vcc 16 to 35 Vcc

Consumption without load 16V - < 37mA / 35V - < 30mA 16V - < 37mA / 35V - < 30mA

Protection reverse polarity and short-circuit I < 20mA reverse polarity and short-circuit I < 20mA

Output voltage13,6V / 1% - without load, 13.4V to 13.8 and >10 to40mA

13,6V / 1% - without load, 13.4V to 13.8 and >10 to40mA

Max. channel output current 40mA 40mA

Led indication Green Led: Power Supply / red blinking: output short-circuited

Short-circuit electronic protection in thesegments

yes yes

Terminator yes yes

Termination resistor indicator no no

Fault monitoring Red led blinking: short-circuit in the spurs

Ex protection Ex i (a barrier for each segment) Ex i (a barrier for each segment)

Network connection 3 ways double plug-in terminal 2.5 mm² 3 ways double plug-in terminal 2.5 mm²

Cable type Profibus PA cable Foundation Fieldbus cable

Input/Output for trunk cable cable gland PG16 cable gland PG16

cable disconnection allowed without interrupting the rest of the network allowed without interrupting the rest of the network

Number of spurs 4, 6 or 8 4, 6 or 8

Spur connections 3 ways pression terminals 2.5 mm² 3 ways pression terminals 2.5 mm²

Housing material aluminum aluminum

Mounting cover 4 screws with rubber gasket 4 screws with rubber gasket

Protection class IP 66 IP 66

Operation temperature -20°C to +55°C -20°C to +55°C

Weight Aprox. 1600g Aprox. 1600g

Accessories included terminal, isolator tube, cover, cable gland terminal, isolator tube, cover, cable gland

Specifications

Barrier 4 points Barrier 6 points

Mechanical Dimensions

Dimension table

FDA

(mm)B

(mm)C

(mm)

PlasticEx i

220 120 91

MetallicEx i

200 120 65

C

A

B

C

A

B

C

A

B

Barrier 8 points

Page 17: FOUNDATION FIELDBUS PROFIBUS PA - Sense

17Sense

FD - Field Barrier Exi with ConnectorThe FD Field Barrier is a fieldbus distributin module that integrates a intrinsic safety barrier for each spur. It´s available with 4, 6 or8 points for spurs with 7 / 8 “or M12 connectors in plastic or Metal box.

MV-4

DF el

ud

oM

7/8" connector model

Network FD4B FD6B FD8B

PA

Plastic PA-FD-4B-VM-Exei PA-FD-6B-VM-Exei PA-FD-8B-VM-Exei

Metallic PA-FDM-4B-VM-Exei PA-FDM-6B-VM-Exei PA-FDM-8B-VM-Exei

FFPlastic FF-FD-4B-VM-Exei FF-FD-6B-VM-Exei FF-FD-8B-VM-Exei

Metallic FF-FDM-4B-VM-Exei FF-FDM-6B-VM-Exei FF-FDM-8B-VM-Exei

Terminator

Networ plug-in terminal

Pression terminal

Protection to the networkterminals in Increased Safety

7/8” Spurconnector

7/8” network connector

Spur Status Led

(blink for short-circuit)

Ground terminal

Module internal view

M12 connector model

Network FD4B FD6B FD8B

PA

Plastic PA-FD-4B-V1-Exei PA-FD-6B-V1-Exei PA-FD-8B-V1-Exei

Metallic PA-FDM-4B-V1-Exei PA-FDM-6B-V1-Exei PA-FDM-8B-V1-Exei

FFPlastic FF-FD-4B-V1-Exei FF-FD-6B-V1-Exei FF-FD-8B-V1-Exei

Metallic FF-FDM-4B-V1-Exei FF-FDM-6B-V1-Exei FF-FDM-8B-V1-Exei

MV-

6DF

elu

do

M

MV-

8DF

elu

do

M

1V-4

DF el

ud

oM

1V-

6DF

elu

do

M

1V-

8DF

elu

do

M

Page 18: FOUNDATION FIELDBUS PROFIBUS PA - Sense

18 Sense

Mechanical Dimensions

Dimension table

FDA

(mm)B

(mm)C

(mm)

PlasticEx i

220 120 91

MetallicEx i

200 120 65

18

A

B

C

Barrier 8 points

Specifications

31

2 4

Macho 7/8” Fêmea 7/8”

Rede IN Spur

Profibus PAPino 1 = Bus +Pino 2 = Not UsedPino 3 = Bus -Pino 4 = S (dreno)

Foundation FieldbusPino 1 = Bus -Pino 2 = Bus +Pino 3 = S (dreno)Pino 4 = Not Used

Rede OUT

13

4 2

Fêmea 7/8”

13

4 2

31

2 4

Macho 7/8” Fêmea M12

Rede IN

13

4 2

Spur

Profibus PAPino 1 = Bus +Pino 2 = Not UsedPino 3 = Bus -Pino 4 = S (dreno)

Foundation FieldbusPino 1 = Bus -Pino 2 = Bus +Pino 3 = S (dreno)Pino 4 = Not Used

Rede OUT

Fêmea 7/8”

13

4 2

MV r

eirra

B1

V reirr

aB* Dimensions for 4 and 6 points

models.

Features PROFIBUS PA FOUNDATION FIELDBUS

Modelo 4 points PA-FDM-4B-VM-Exei FF-FDM-4B-VM-Exei

Modelo 6 points PA-FDM-6B-VM-Exei FF-FDM-6B-VM-Exei

Modelo 8 points PA-FDM-8B-VM-Exei FF-FDM-8B-VM-Exei

Function Intrinsic Safety barrier Intrinsic Safety barrier

Operating voltage 16 to 35 Vdc 16 to 35 Vdc

Consumption without load 16V - < 37mA / 35V - < 30mA 16V - < 37mA / 35V - < 30mA

Protection reverse polarity and short-circuit I < 20mA reverse polarity and short-circuit I < 20mA

Output voltage13,6V / 1% - without load, 13,4V to 13,8V and >10 to40mA

13,6V / 1% - without load, 13,4V to 13,8V and >10 to 40mA

Max. channel output current

Led indication Green Led: power supply / red blinking: output short-circuited

Short-circuit electronic protection in thesegments

yes yes

Terminator yes yes

Terminating resistor indicator no no

Fault monitoring Red led blinking: short-circuit in the spurs

Ex protection Ex i (a barrier for each segment) Ex i (a barrier for each segment)

Network connection 3 ways double plug-in terminal 2.5 mm² 3 ways double plug-in terminal 2.5 mm²

Cable type Profibus PA cable Foundation Fieldbus cable

Input/Output for trunk cable via 7/8" connector via 7/8" connector

cable disconnection allowed without interrupting the rest of the network allowed without interrupting the rest of the network

Number of spurs 4, 6 or 8 4, 6 or 8

Spur connections via 7/8" connector via 7/8" connector

Housing material aluminum aluminum

Mounting cover 4 screws with rubber gasket 4 screws with rubber gasket

Protection class IP 66 IP 66

Operation temperature -20°C to +55°C -20°C to +55°C

Weight Approx. 1600g Approx. 1600g

Accessories included kit terminal,tubo isolador, tampão kit terminal, tubo isolador, tampão

Page 19: FOUNDATION FIELDBUS PROFIBUS PA - Sense

19Sense

Code Key

PA - FD M - 8 B - VM - Ex

PA - Profibus PAFF - Foundation Fieldbus

Network

- : PlasticM : Metal

Material

MD - 2 or 4 points FD - 4, 6 or 8 points

Housing2 - 2 points 4- 4 points 6 - 6 points 8 - 8 points

Spurs

D- Derivador PassivoP - Protector deSegmentoIntrinsic Safety

Tipo

- TerminalV1 - M12 Connector VM - 7/8" Connector

Connetion

D- Passive DerivatorP - Segment ProtectorB - Intrinsic Safety Barrier

Type

- general purposeEx - For PotentiallyExplosive Atmospheree - Increased Safetyi - Intrinsic Safety

Version

Available:

Cable Gland (PG16 available)

11

GP

11

ex

E G

P

11 i

xE

GP

11 -

e x

E-P

Tr

otc

en

no

C

rot

ce

no

C

rot

ce

no

C

general purpose Ex e Ex i

Covers ( PG16 available)

Connectors

7/8" male 7/8" Female M12 Male

Page 20: FOUNDATION FIELDBUS PROFIBUS PA - Sense

20 Sense

www.sense.com.br

20000000049 Rev.B - 05/14 - All information above may be modified with no previous notice..

Contact us:

HEADQUARTERSRua Tuiuti, 1237 - Tatuapé

São Paulo - SP - Cep: 03081-000Fone: 55 11 6190-0444

Fax:(11) [email protected]

FACILITY Av. Joaquim Moreira Carneiro. 600 - SantanaSanta Rita do Sapucaí - Minas Gerais - Cep:

37540-000Fone: 55 35 3471-2555Fax: 55 35 3471-2033