2
x 1 C-11 C-12 C-2 C-3 C-4 1544 kbit/s 2048 kbit/s 6312 kbit/s VC-11 VC-12 VC-2 VC-3 VC-4 STM-1 AU-3 AU-4 34368 kbit/s VC-3 TU-11 x 4 x 3 x 3 x 3 x 1 x 1 x 1 x 7 x 7 TU-12 TU-2 TU-3 C-n Pointer Processing Multiplexing Aligning Mapping Container-n 139264 kbit/s TUG-3 AUG TUG-2 SDH Mapping according G.707 Aggregates Tributaries ����UBUS 8 x 2 Mbit/s 1) 2) FOX515 only Depends on the V5 protocol type 3) Can also be used as ATM bus. Please contact ABB for more details about ATM features on the FOX platform. PBUS 40 x 2 Mbit/s or 128 x 2 Mbit/s (upgrade possible); VC12 +/-5 VDC POSUS/POSUM Power Converter –48 VDC POSUS/POSUM n+1 Control and Power Units Ext. clock input (2) Clock output (3) Ext. alarm input (4) Alarm relay output (2) F-interface Q1-interface Qx-interface } UCST UNEM COBU < x > Redundant COBU < x > 8 x 2 Mbit/s 8 x 2 Mbit/s 24 input el. 8 output el. ALCAR 24 Alarm Inputs 4 Contact Outputs 4 Serial Ports max. 5 x ALCAR/FOX EXT. ALARMS 2 x UA, 2 x NA 4 x ext. Alarms V9VK Alarm Module V9VK UBUS <> PBUS interconnection Synchronization MIB Alarm IF Management Communication Options: - COBUV: includes Voice Conference - 40 or 128 Mbit/s PBUS capacity 2048 kHz high/low open/close RS232, 1154 kbit/s RS 485 10Base T UBUS UNITS SBUS (SDH) Units SYNAC channels: 8 SYNVA channels: 32 SYNAM electrical: 8 IFs 8x2 Mbit/s G.703 SYTEL electrical: 1 IF 34/45 Mbit/s SYNAD electrical: 16 IFs 16x2 Mbit/s G.703 SYNIO STM-1optical IF optical: 2 IFs SYNIF STM-1optical IF optical: 1 IF 2x155 Mbit/s opt. S1.1 L1.1, L1.2 G. 957 155 Mbit/s opt. S1.1 L1.1, L1.2 G.957 SYNIC STM-1 electrical IF electrical: 1 IF 155 Mbit/s G. 703, coaxial DPF Dual Power Feeder R1AH Redundant Power Feeding –48 VDC –48 VDC 1) } –48 VDC +/-5 VDC POSUA AC/DC converter & Battery Charger –48 VDC BATMO -48 Backup-Battery 230 VAC 115 VAC –48 VDC OHC OHC OHC 8 x 2 Mbit/s 32 x TU12 PAX EXLAx Exchange line IF 12 ports 2 w a, b 64k PAX NEMCA Voice freq. IF 8 ports 2/4 w a, b 64k E&M (E'&M') 64k GECOD 64 kbit data IF 8 ports 64k G.703 DTE PAX EXLIC/EXLOC ISDN-U (2B1Q) Exchange line IF 8 ports 2 w a, b 64k NT-1 2 w a, b S0 64k ISDN 144k 2B1Q SULIS ISDN-U (2B1Q) Subscr. line IF 8 ports NT-1 S0 2 w a, b 64k ISDN 144k 2B1Q ISBUQ (V5) ISDN-U (2B1Q) Subscr. line IF 8 ports NT-1 S0 2 w a, b 64k ISDN 144k 4B3T ISBUT (V5) ISDN-U (4B3T) Subscr. line IF 8 ports n x 64k n x 64k n x 64k n x 64k n x 64k n x 64k n x 64k n x 64k DTE UNIDA 431 UNIDA 432 UNIDA 433 UNIDA 434 UNIDA 435 4 x X.24/V.11 2 x V.36 RS449 4 x V.36 RS449 4 x V.35 4 x V.24/V.28 (RS232) UNIDA 436 UNIDA 437 UNIDA 438 4 x X.24/V.11 4 x V.35 4 x X.24/V.11 64k 4 x Teleprotection Commands 8 x Binary Signals 1 x IRIG TEBIT 4x Teleprotection 8x Binary n x 64k (n=1...20) 1 x optical OTERM ����3) SYNOT STM-1 optical IF optical: 1 IF 155 Mbit/s opt. S1.1 L1.1, L1.2 G. 957 OHC n � 5 2B1Q 8 xVC-12 32 xVC12 SBUS 2 Segments: Segment 1 Slot 2..9; Segment2 Slot 15..20; 2 x VC4 3) NEBRO electrical: 4 IFs 2x cages supporting SFP PBUS UNITS LAWA4 10BaseT Ethernet 2 x 2 Mbit/s LOMIF 2 Mbit/s IF 8 ports 8 x 2 Mbit/s G.703/G.704 8 x 2 Mbit/s LOMI4 2 Mbit/s IF 4 ports 4 x 2 Mbit/s G.703/G.704 4 x 2 Mbit/s TUPON Optical/el. IF 8 Mbit/s opt. 4 x2 Mbit/s G.703/G.704 4 x 2 Mbit/s OHC MUSIC100 (SOHO desktop) DSL DSL 1 IF data 1 IF RS 232C Local management 10BaseT Ethernet (with 4-port-Hub) CAP or 2B1Q PHL C1 60 ports 2 w a, b 2 x 2 Mbit/s PCONV V.5x Protocol conv. 2 ports 2 x 2 Mbit/s G.703/G.704 8 x 2 Mbit/s 10 x 2 Mbit/s 2) PCON2 V.5x Protocol conv. 2 w a, b 2 Mbit/s 2 w a, b 2 Mbit/s 8 x 2 Mbit/s LESA8 8 x 2 /4W HDSL CAP/2B1Q 2 x 4W HDSL CAP/2B1Q 2 x G.703 front access 4 x 2 Mbit/s SLIM2 Power: 2 IFs 2 x 4W HDSL CAP/2B1Q 2 x G.703 front access 4 x 2 Mbit/s SLIM1 2 Mbit/s G.703/G.704 or n x 64 kbit/s G.703/G.704 X.21/V.11 or V.35 or V.36 CAP or 2B1Q LECAR (desktop) DSL transm. DSL 2 IFs data 1 IF 2 Mbit/s G.703/G.704 or n x 64 kbit/s G.703/G.704 X.21/V.11 or V.35 or V.36 CAP MUSIC200 (LESAR desktop) DSL transm. DSL 2 IFs data 1 IF 2 x 2 Mbit/s LEMU6 6 x HDSL 10BaseT Ethernet ETHUB Ethernet Hub 5 x 10/100BaseT 8 Mbit/s opt. TUPON Optical/el. IF 4 x2 Mbit/s G.703/G.704 8 Mbit/s opt. TUNOR Optical/el. IF 4 x2 Mbit/s G.703/G.704 optical: 2 IFs (cages) 4x10/100 Base T 100 Base FX/G6E ����������������������UNEM Basic Package - Graphical network management - Configuration management - Performance management - Fault management - Security management - Supported NE: FOX515, FOX512, FOX-U, FOX-U/M, FOX-U/E - 4 Element Agent - Scalable Licence-fee available - Various options available, e.g. end to end configuration tool UNEM (Universal Network Manager) A - b . c 1: 1310 nm 2: 1550 nm 1 STM-1 4 STM-4 16 STM-16 64 STM-64 I Intra Office S Shorthaul L Longhaul Optical Port Designations according G.957 Example: L-1.2 Longhaul STM-1 1550nm We reserve all rights in this document and in the information contained therein. This system overview does neither claim completeness nor availability of modules or functions and ABB reserves the right to insert, postpone or remove modules and functions without further notice. Reproduction, use or disclosure to third parties without express authority is strictly forbidden. © ABB Switzerland Ltd, Utility Automation; 2003 Bus Structure Bus Hierarchy Capacity UBUS PDH 8 x 2 Mbit/s PBUS PDH/SDH 40 x 2 Mbit/s or 128 x 2 Mbit/s SBUS SDH 2 x VC4 Synchronisation Quality Levels according G.707 QL SDH synchronisation quality level description 0 Quality unknown (Existing Sync. Network) 1 Reserved 2 Rec. G.811 3 Reserved 4 Rec. G.812 transit 5 Reserved 6 Reserved 7 Reserved 8 Rec. G.812 local 9 Reserved 10 Reserved 11 Synchronous Equipment Timing Source (SETS) 12 Reserved 13 Reserved 14 Reserved 15 Do not use for synchronization Available UNIDA-Options: VU-OPT1: VU-OPT2: VU-OPT3: VU-OPT4: 1+1 protection point-multipoint communication performance monitoring subrate multiplexer UNIDA-Options FOX 512 & FOX 515 Overview www.abb.com/utilitycommunications

FOX 512 & FOX 515 Overview - ABB Group · x 1 C-11 C-12 C-2 C-3 C-4 1544 kbit/s 2048 kbit/s 6312 kbit/s VC-11 VC-12 VC-2 VC-3 STM-1 VC-4 AU-3 AU-4 34368 kbit/s VC-3 TU-11 x …

Embed Size (px)

Citation preview

Page 1: FOX 512 & FOX 515 Overview - ABB Group · x 1 C-11 C-12 C-2 C-3 C-4 1544 kbit/s 2048 kbit/s 6312 kbit/s VC-11 VC-12 VC-2 VC-3 STM-1 VC-4 AU-3 AU-4 34368 kbit/s VC-3 TU-11 x …

x 1

C-11

C-12

C-2

C-3

C-4

1544 kbit/s

2048 kbit/s

6312 kbit/s

VC-11

VC-12

VC-2

VC-3

VC-4STM-1

AU-3

AU-4

34368 kbit/s

VC-3

TU-11

x 4

x 3

x 3

x 3 x 1

x 1

x 1

x 7x 7

TU-12

TU-2

TU-3

C-n

Pointer Processing

MultiplexingAligningMapping

Container-n

139264 kbit/s

TUG-3

AUG

TUG-2

SDH Mapping according G.707

Ag

gre

gat

esTr

ibut

arie

s

UB

US

8

x 2

Mb

it/s

1)

2)

FOX 515 onlyDepends on the V5 protocol type

3) Can also be used as ATM bus. Please contact ABB for more details about ATM features on the FOX platform.

PB

US

40

x 2

Mb

it/s

or

128

x 2

Mb

it/s

(up

gra

de

po

ssib

le);

VC

12

+/-5 VDCPOSUS/POSUMPower Converter–48 VDC

POSUS/POSUM n+1

Control and Power Units

Ext. clock input (2)Clock output (3)

Ext. alarm input (4)Alarm relay output (2)

F-interfaceQ1-interface

Qx-interface UCST

UNEM

COBU < x >

Redundant COBU < x >

8 x 2 Mbit/s

8 x 2 Mbit/s

24 inputel.

8 outputel.

ALCAR24 Alarm Inputs

4 Contact Outputs4 Serial Ports

max. 5 x ALCAR/FOX

EXT. ALARMS

2 x UA, 2 x NA4 x ext. Alarms

V9VKAlarm Module

V9VK

UBUS <—> PBUS interconnectionSynchronizationMIBAlarm IFManagement Communication

Options:- COBUV: includes Voice Conference- 40 or 128 Mbit/s PBUS capacity

2048 kHz

high/lowopen/close

RS232, 1154 kbit/s

RS 48510Base T

UBUS UNITS SBUS (SDH) Units

SYNACchannels: 8

SYNVAchannels: 32

SYNAMelectrical: 8 IFs

8x2 Mbit/s G.703

SYTELelectrical: 1 IF 34/45 Mbit/s

SYNADelectrical: 16 IFs 16x2 Mbit/s G.703

SYNIOSTM-1optical IF optical: 2 IFs

SYNIFSTM-1optical IF optical: 1 IF

2x155 Mbit/s opt.S1.1L1.1, L1.2G. 957

155 Mbit/s opt.S1.1L1.1, L1.2G.957

SYNICSTM-1 electrical IFelectrical: 1 IF

155 Mbit/sG. 703, coaxial

DPFDual Power Feeder

R1AH

RedundantPowerFeeding

–48 VDC

–48 VDC1) –48 VDC

+/-5 VDC POSUAAC/DC converter& Battery Charger–48 VDC

BATMO-48 Backup-Battery

230 VAC115 VAC

–48 VDC

OHC

OHC

OHC

8 x 2 Mbit/s

32 x TU12

PAX EXLAx

Exchange line IF12 ports

2 w a, b 64k

PAX NEMCA

Voice freq. IF8 ports

2/4 w a, b64k

E&M

(E'&M')

64kGECOD

64 kbit data IF8 ports

64k

G.703DTE

PAXEXLIC/EXLOCISDN-U (2B1Q)Exchange line IF

8 ports

2 w a, b 64k

NT-12 w a, bS0 64k

ISDN144k2B1Q

SULISISDN-U (2B1Q)

Subscr. line IF8 ports

NT-1S0 2 w a, b 64k

ISDN144k2B1Q

ISBUQ (V5)ISDN-U (2B1Q)

Subscr. line IF8 ports

NT-1S0 2 w a, b 64k

ISDN144k4B3T

ISBUT (V5)ISDN-U (4B3T)

Subscr. line IF8 ports

n x 64k

n x 64k

n x 64k

n x 64k

n x 64k

n x 64k

n x 64k

n x 64k

DTE

UNIDA 431

UNIDA 432

UNIDA 433

UNIDA 434

UNIDA 435

4 x X.24/V.11

2 x V.36 RS449

4 x V.36 RS449

4 x V.35

4 x V.24/V.28(RS232)

UNIDA 436

UNIDA 437

UNIDA 438

4 x X.24/V.11

4 x V.35

4 x X.24/V.11

64k

4 x Teleprotection Commands

8 x Binary Signals

1 x IRIG

TEBIT4x Teleprotection

8x Binary

n x 64k

(n=1...20)

1 x opticalOTERM

3)

SYNOTSTM-1 optical IFoptical: 1 IF

155 Mbit/s opt.S1.1L1.1, L1.2G. 957OHC

n 5

2B1Q

8 xVC-12

32 xVC12

SBU

S 2

Seg

men

ts: S

egm

ent 1

Slo

t 2..9

; Seg

men

t2 S

lot 1

5..2

0; 2

x V

C43)

NEBROelectrical: 4 IFs 2x cages supporting SFP

PBUS UNITS

LAWA 4 10BaseT Ethernet

2 x 2 Mbit/s

LOMIF

2 Mbit/s IF8 ports

8 x 2 Mbit/s G.703/G.7048 x 2 Mbit/s

LOMI4

2 Mbit/s IF4 ports

4 x 2 Mbit/s G.703/G.7044 x 2 Mbit/s

TUPONOptical/el. IF

8 Mbit/s opt.

4 x2 Mbit/s G.703/G.704

4 x 2 Mbit/s

OHC

MUSIC100(SOHO desktop) DSL

DSL 1 IFdata 1 IF

RS 232CLocal management

10BaseT Ethernet (with 4-port-Hub)

CAP or2B1Q

PHL C160 ports

2 w a, b2 x 2 Mbit/s

PCONVV.5x Protocol conv.

2 ports2 x 2 Mbit/s G.703/G.704

8 x 2 Mbit/s

10 x 2 Mbit/s2) PCON2

V.5x Protocol conv.

2 w a, b 2 Mbit/s

2 w a, b2 Mbit/s

8 x 2 Mbit/sLESA8

8 x 2 /4W HDSL CAP/2B1Q

2 x 4W HDSL CAP/2B1Q

2 x G.703 front access4 x 2 Mbit/s SLIM2

Power: 2 IFs

2 x 4W HDSL CAP/2B1Q

2 x G.703 front access4 x 2 Mbit/s

SLIM1

2 Mbit/s G.703/G.704orn x 64 kbit/s G.703/G.704X.21/V.11 or V.35 or V.36

CAP or2B1Q

LECAR (desktop)DSL transm.DSL 2 IFsdata 1 IF

2 Mbit/s G.703/G.704orn x 64 kbit/s G.703/G.704X.21/V.11 or V.35 or V.36

CAPMUSIC200 (LESAR desktop)

DSL transm.DSL 2 IFsdata 1 IF

2 x 2 Mbit/sLEMU 6

6 x HDSL

10BaseT Ethernet

ETHUBEthernet Hub 5 x 10/100BaseT

8 Mbit/s opt.TUPON

Optical/el. IF4 x2 Mbit/s G.703/G.704

8 Mbit/s opt.TUNOR

Optical/el. IF4 x2 Mbit/s G.703/G.704

optical: 2 IFs (cages)

4x10/100 Base T

100 Base FX/G6E

UNEM Basic Package

- Graphical network management- Configuration management- Performance management- Fault management- Security management- Supported NE: FOX 515, FOX 512,

FOX-U, FOX-U/M, FOX-U/E

- 4 Element Agent- Scalable Licence-fee available- Various options available,

e.g. end to end configuration tool

UNEM (Universal Network Manager)

A - b . c

1: 1310 nm2: 1550 nm

1 STM-14 STM-4

16 STM-1664 STM-64

I Intra OfficeS ShorthaulL Longhaul

Optical Port Designationsaccording G.957

Example: L-1.2 Longhaul STM-1 1550nm

We reserve all rights in this document and in the information contained therein. This system overview does neither claim completeness nor availability of modules or functions and ABB reserves the right to insert, postpone or remove modules and functions without further notice.Reproduction, use or disclosure to third parties without express authority is strictly forbidden. © ABB Switzerland Ltd, Utility Automation; 2003

Bus Structure

Bus Hierarchy Capacity

UBUS PDH 8 x 2 Mbit/sPBUS PDH/SDH 40 x 2 Mbit/s or

128 x 2 Mbit/s

SBUS SDH 2 x VC4

Synchronisation Quality Levels according G.707

QL SDH synchronisation quality level description0 Quality unknown (Existing Sync. Network)1 Reserved2 Rec. G.8113 Reserved4 Rec. G.812 transit5 Reserved6 Reserved7 Reserved8 Rec. G.812 local9 Reserved

10 Reserved11 Synchronous Equipment Timing Source (SETS)12 Reserved13 Reserved14 Reserved15 Do not use for synchronization

Available UNIDA-Options:

VU-OPT1:VU-OPT2:VU-OPT3:VU-OPT4:

1+1 protectionpoint-multipoint communicationperformance monitoringsubrate multiplexer

UNIDA-Options

FOX 512 & FOX 515 Overview

www.abb.com/utilitycommunications

Page 2: FOX 512 & FOX 515 Overview - ABB Group · x 1 C-11 C-12 C-2 C-3 C-4 1544 kbit/s 2048 kbit/s 6312 kbit/s VC-11 VC-12 VC-2 VC-3 STM-1 VC-4 AU-3 AU-4 34368 kbit/s VC-3 TU-11 x …

FOX 515 MAIN CHARACTERISTICS

RecommendationsITU-T G.702, G.703, G.704, G.706, G.707, G.711, G.712-G.715,

G.732, G.735, G.736, G.737,G.742, G.821, G.823, G.826, G.957, Q.920, Q.921, Q.922

CrossconnectDXC Modular non blocking cross connect capacity

40 x 2Mbit/s with COBUX 137; COBUV145 128 x 2Mbit/s with COBUX 237; COBUV146 Cross connections at 64 kBit/s, n x 64k Bit/s and 2 Mbit/s

CapacityUBUS 8 x 2 Mbit/sPBUS 40 or 128 x 2 Mbit/s (upgrade 40 -> 128 possible)SBUS 2 x 2 x VC4FOX-U compatibilityTributary channels Supports up to 240 channels as tributary from UBUS

modulesTraffic protection1+1 protection (n x 64 kBit/s) NEMCA, GECOD SULIC, UNIDA, TEBITLTP SYNAC, SYTELSNCP LOMIF, SYNACMSP SYNIOAmbient conditionsStorage Acc ETSI 300 019-1-1 class 1.2

–25° C..+55° CTransport Temperature ranges Acc ETS 300 019-1-2 class 2.2 –unventilated enclosures –25° C..+70° C –ventilated enclosures / outdoor –25° C..+40° C Vibration ASD @ 10..200Hz 1.0 m2s-3 ASD @ 200..2000Hz 0.3 m2s-3Operation Acc ETS 300 019-1-3 class 3.2Operation temperature operational applications –5° C up to 55° CxDSL, ISDN and ATM applications –5° C up to 45° CHumidity 95% non condensingMechanical dimensionsSubrack with front cover (WxHxD) 482.6 x 308.2 x 303 mmCable tray (WxHxD) 482.6 x 87.1 x 240 mmHeat deflection shield (WxHxD) 482.6 x 87.8 x 237 mmNumber of available slots 21 (including 1 or 2 slots for COBU<x>)TypetestsKEMA Typetest 98430060-tdp 99-1010Power SupplyVoltage -48 VDC (-40.5..-57 VDC) -60 VDC (-50.5..-72 VDC)With POSUA 115 VAC (88 VAC 132 VAC)With POSUA 230 VAC (176 VAC 264 VAC)DependabilityMADT (Mean Accumulated Down TimeTraffic between any 2 Mbit/s ports) <10’ per yearMTTF > 20 years per unit

FOX 512 MAIN CHARACTERISTICS

RecommendationsITU-T G.702, G.703, G.704, G.706, G.707, G.711, G.712-G.715,

G.732, G.735, G.736, G.737,G.742, G.821, G.823, G.826, G.957, Q.920, Q.921, Q.922

CrossconnectDXC Modular non blocking cross connect capacity

40 x 2 Mbit/s with COBUX 137; COBUV145 128 x 2 Mbit/s with COBUX 237; COBUV146 Cross connections at 64kBit/s, n x 64 kBit/s and 2 Mbit/s

CapacityUBUS 8 x 2 Mbit/sPBUS 40 or 128 x 2 Mbit/s (upgrade 40->128 possible)SBUS 2 x 2 x VC4FOX-U compatibilityTributary channels Supports up to 240 channels as tributary from UBUS

modulesTraffic protection1+1 protection (n x 64kBit/s) NEMCA, GECOD SULIC, UNIDA, TEBITLTP SYNAC, SYTELSNCP LOMIF, SYNACMSP (Multiplex Section Protection) SYNIOAmbient conditionsStorage Acc ETSI 300 019-1-1 class 1.2

–25° C..+55° CTransport Temperature ranges Acc ETS 300 019-1-2 class 2.2 –unventilated enclosures –25° C..+70° C –ventilated enclosures / outdoor –25° C..+40° C Vibration ASD @ 10..200Hz 1.0 m2s-3 ASD @ 200..2000Hz 0.3 m2s-3Operation Acc ETS 300 019-1-3 class 3.2Temperature range system (extended) –20° C..+55° C with old UBUS units –10° C .. +55° CStart up temperature –20° C with old UBUS units –5° CHumidity 95% non condensingMechanical dimensionsSubrack with front cover (W x H x D) 482.6 x 177x 283 mmNumber of available slots 8Power SupplyVoltage -48 VDC (-40.5..-57 VDC)

–60 VDC (–50.5..-72 VDC)With POSUA 115 VAC (88 VAC 132 VAC)With POSUA 230 VAC (176 VAC 264 VAC)Power ConsumptionMax Power Consumption- -48 VDC 144 W- -60 VDC 180 W– Mains Power Interface 180 WDependabilityMTTF > 20 years per unit

BASIC MODULES

COBUX Control unitNetwork management interfaces Qx – interface 10BaseT IEEE 802.3

Q1 – interface RS 485 F- interface V24/V28 (RS 232) 4 Alarms input, 2 Alarm relay output 2 synchronisation inputs, 3 synchronisation outputs

Features TCP/IP tunnelling, ECC, diagnosticsOptions 1+1 equipment protectionModule width 1COBUV Control unit with conference Network management interfaces Qx – interface 10BaseT IEEE 802.3

Q1 – interface RS 485 F- interface V24/V28 (RS 232) 4 Alarms input, 2 Alarm relay output 2 synchronisation inputs, 3 synchronisation outputs

Features TCP/IP tunnelling, ECC, diagnostics Options 1+1 equipment protectionModule width 1Voice conference (partyline) Possible conferences: max. 21 Possible conference parties: max. 64V9VK Alarm module Alarm output duplication UA: 2 NA: 2ALCAR Alarm interfaceInterfaces 24 Alarm inputs

4 Binary outputs 4 serial interfaces

Maximum number of modules per FOX 5Module width 1POSUS Power supplyInternal supply voltage 5 VSupplied power 50 WModule width 1POSUM Power supplyInternal supply voltage 5 VSupplied power 85 WModule width 1Dual power feeder (FOX 515 only)Number of power sources 2Feeding voltage 48 VDCPOSUANominal input voltage 115 VAC (88 VAC 132 VAC) 220 VAC (176 VAC 264 VAC)Frequency 45..63 HzMax. converted power 140 WMax. consumed power 180 WCharger interface (battery connected)nominal voltage @ 20° C: -54.6 VDCtemperature compensation (-10° C +50° C) +72 mV/° Cdeviation of compensated voltage < 2 %Module width 2BATMO DC Battery backup interface (FOX 512 only)Interface Access POSUAFANUV (FOX 515)Number of fans 3Operation temperature controlled

(<30° C low speed/>50° C high speed)Installation Does not require a “Unit”-SlotFANU2 (FOX 512)Number of fans 2Operation temperature controlled

(<30° C low speed/>50° C high speed)Installation Does not require a “Unit”-Slot

TECHNICAL DATA OF FOX-512 & FOX-515

1KH

A -

000

744

- S

EN

10

00

11.0

4 P

rinte

d in

Sw

itzer

land

SDH MODULES

SYNIO STM1 optical aggregateInterface type STM-1 Aggregate S1.1 L1.1 L1.2Wavelength 1310 nm 1310 nm 1550 nmLaunched power -10 ± 2 dBm –2 ± 2 dBm -2 ± 2 dBm Minimum sensitivity -38 dBm -38 dBm -38 dBmAttenuation range 24 dB 32 dB 32 dBNumber of ports 2Connector type E2000 (type LSH-HRL)Module width 2SYNIF STM1 optical aggregateInterface type STM-1 aggregate S1.1 L1.1 L1.2Wavelength 1310 nm 1310 nm 1550 nmLaunched power ±-10 ± 2 dBm -2 ± 2 dBm -2 ± 2 dBm Minimum sensitivity -38 dBm -38 dBm -38 dBmAttenuation range 24 dB 32 dB 32 dBNumber of ports 1Connector type E2000 (type LSH-HRL)Module width 1SYNOTInterface type STM-1 Tributary, S1.1 L1.1 L1.2Wavelength 1310 nm 1310 nm 1550 nmLaunched power –10 ± 2 dBm –2 ± 2 dBm –2 ± 2 dBmMinimum sensitivity -38 dBm -38 dBm -38 dBmAttenuation range 24 dB 32 dB 32 dBNumber of ports 1Connector type E2000 (type LSH-HRL)Module width 1SYNICInterface type STM-1 electricalNumber of ports 1Code CMIImpedance 75 Ω asymmetricsignal attenuation 0..12.7 dB @78 MHzJitter Acc. G.825Connector type Coaxial, 75 Ω Series 1.6/5.6 msModule width 1SYNAC VC 12 terminationCapacity 8 x VC12 terminationPath protection LTP supportedModule width 1SYNVACapacity 32 x VC12 SBUS<->PBUS interconnectionInterface type No physical interfaceModule width 1SYNAMInterface Type G.703,Bitrate 2048 kBit/s ± 50 ppmLine impedance 75 Ω asymmetrical or 120 Ω symmetricalNumber of interfaces per module 8Traffic protection LTP on VC12Performance monitoring Acc. G.826Module width 1SYNADInterface type G.703,Bitrate 2048 kBit/s ± 50 ppmLine impedance 75 Ω asymmetrical or 120 Ω symmetricalNumber of interfaces per module 16Traffic protection LTP on VC12Performance monitoring Acc. G.826Module width 1SYTELInterface type 34/45 Mbit/s tributary interfaceLine impedance -Number of interfaces per module 1Traffic protection LTPModule width 1

PDH OPTICAL MODULES

TUPON 8448 kBit/s optical interfaceInterface type 8 Mbit/s PDHWavelength 1300 nm 1500 nmLaunched power –10 ± 2 dBm –2 ± 2 dBmMinimum sensitivity –40 dBm –40 dBmAttenuation range 26 dB 34 dBNumber of ports 1Connector type E2000 (type LSH-HRL)Optical code MCMI + telemetryNumber of electrical ports 4Interface type G.703Module width 1TUNOR 8448 kBit/s optical desktopMultiplexing procedure G.742Transmission code MCMI + telemetryAllowed fibre attenuation Up to 20 dB (approx. 30 km)Optical wavelength 1300 nmNumber of optical ports 1Connector type FC/PCNumber of electrical ports 4Interface type G.703Module width 1

PDH ELECTRICAL MODULES

LOMIF 2 Mbit/s electrical interface:Interface type G.703,Bitrate 2048 kBit/s ± 50 ppmLine impedance 75 Ω asymmetrical or 120 Ω symmetricalNumber of interfaces per module 8Traffic protection Subnetwork connection protection at 2 Mbit/sPerformance monitoring Acc. G.826Module width 1LOMI4 2 Mbit/s electrical interfaceInterface type G.703,Bitrate 2048 kBit/s ± 50 ppmLine impedance 75 Ω asymmetrical or 120 Ω symmetricalNumber of interfaces per module 4Traffic protection Subnetwork connection protection at 2 Mbit/sPerformance monitoring Acc. G.826Module width 1

HDSL MODULES

LEMU6 HDSL module for SOHONumber of DSL interfaces 6 x 1 pairLine code CAPLine bit rates 128..2048 kBit/sTransmission range Up to 16 km Performance monitoring Acc. G.826Additional features Bridging, with diverse sub modes

IP static routing IP OSPF V2 dynamic routing Unnumbered IP links on DSL and PBUS interfaces Frame relay FRAD functionality DHCP relay configurable for SOHO IP managed bridge configurable for SOHO

Module width 1LESA8Number of DSL interfaces 8 x 1pair or 4 x 2 pairLine code CAP, 2B1Q, PAM16, G.SHDSLLine bit rates 2 x 1168 or 1 x 2048 kBit/sTransmission range Up to 16 kmTransmission mode 1pair, 2pair or mixedPerformance monitoring Acc. G.826Remote powering Not supportedModule width 1SLIM1Number of DSL interfaces 2 x 1 pair or 2 x 2pairLine code CAP, 2B1Q, PAM16Line bit rates 2 x 1168 or 1 x 2048 kBit/sTransmission range Up to 16 km Transmission mode 1pair, 2pair or mixedNumber of G.703 interfaces 2 x E1/G.703Performance monitoring Acc. G.826Remote powering Not supported Module width 1SLIM2Number of DSL interfaces 2 x 1 pair or 2 x 2pairLine code CAP, 2B1Q, PAM16Line bit rates 2 x 1168 or 1 x 2048 kBit/sTransmission range Up to 16 km Transmission mode 1pair, 2pair or mixedNumber of G.703 interfaces 2 x E1/G.703Performance monitoring Acc. G.826Remote powering Supported on two ports (2pair mode)Module width 1LECAR HDSL modemInterfaces G.703 / G.704; X.21 / V.11,

V.35, V.36, LAN 1 x 10BaseT (with bridge IEEE 802.1d / router)

Line code CAPDimensions 240 x 42 x 280 mmMUSIC 100 (SOHO) HDSL modemInterfaces LAN 4 x 10BaseT (with bridge IEEE 802.1d / Router)WAN interface Cc. Q.920, Q.921, Q.922MUSIC 200 (LESAR) HDSL modemInterfaces 2DSL ports

1 fixed G.703 75∋P /120∋P or 1 modular interface (G.703/75 Ω, V.11/X.21, V.35, V.36, 10BaseT)

Line code CAP, 2B1Q, PAM16, G.SHDSLTransmission mode 1 and 2 pair serviceVC12 to the desktop SupportedRemote powering Not suportedLocal power supply AC or DC supported

TELEPHONY MODULES

EXLAN Analogue exchange interfacesITU-T coding A-law acc. G.711Characteristics of 2 wire voice channels Q.552Number of interfaces 12Nominal impedance ComplexChannel bandwidth 300..3400 HzSignalling, basic functions Seizure, ringing, ringing off, transmission of flash pulses,

pulse dialling, DTMF without accompanying signal, earth key, charging using 12/16 kHz pulses

Module width 2NEMCA NF interfaces with E&M signallingITU-T coding A-law G.711Characteristics of voice channels G.712-G.715Channel bandwidth 300..3400 HzNumber of interfaces 8E&M Signalling signalling type Type II; signalling circuits E, M, E’, M’ Module width 1

PSTN MODULES

PHLC1 Subscriber line interfacesITU-T coding A-law acc. G.711Characteristics of 2 wire voice channels Q.552Number of interfaces 60 ports a/bNominal impedance ProgrammableChannel bandwidth 300..3400 HzModes V5.x, MCAS, carrier adapter, phone-exchange

Full test for subscriber lines is included Ring over b-wire

Module width 3PHLC2/SUBH3 Subscriber line interfacesITU-T coding A-law acc. G.711Characteristics of 2 wire voice channels Q.552Number of interfaces 30 ports a/bNominal impedance ProgrammableChannel bandwidth 300..3400 HzModes V5.x, MCAS, carrier adapter, phone-exchange

Full test for subscriber lines is included Ring over b-wire

Module width 2 (PHLC2), 1 (SUBH3)PHLC3/SUBH1 Subscriber line interfacesITU-T coding A-law acc. G.711Characteristics of 2 wire voice channels Q.552Number of interfaces 10 ports a/bNominal impedance ProgrammableChannel bandwidth 300..3400 HzModes V5.x, MCAS, carrier adapter, phone-exchange Full test for subscriber lines is included Ring over b-wireModule width 2 (PHLC3), 1 (SUBH1)PCONV V5x Protocol converterSupported protocols V5.1, V5.2Number of E1 interfaces 2 x 2 Mbit/sV.5.1 interfaces (= links) 4V.5.2 interfaces 1V.5.2 link 2PSTN user ports 240ISDN-BA user ports 112 including

- processing of p- and f-data - digital leased lines

Module width 1PCON2 V5x Protocol converterSupported protocols V5.1, V5.2Number of E1 interfaces 2 x 2 Mbit/sV.5.1 interfaces (= links) 10V.5.2 interfaces 1V.5.2 links 8PSTN user ports 480 ISDN-BA user ports 224 including - processing of p- and f-data - digital leased linesModule width 1

Ethernet / TCP/IP MODULES

NEBROInterface type Ethernet 10/100 BaseTNumber of interfaces 4Interface type Ethernet 100 Base FX/GbENumber of interfaces 2 cages supporting SFPSwitching 8 local WAN portsAdditional features ITU-T G.707–Virtual concatenation

ITU-T G.7041– GFP ITU-T G.7043 – LCAS

SBUS capacity Up to 63xVC–12/3xVC–3Module width 1LAWA4Interface type Ethernet 10BaseTNumber of interfaces 1Routing protocol OSPF V2Additional features Layer 2 or 3 IP concentration

Frame Relay FRAD functionality Static routing Support of VLAN (port based, TDM or IEEE 802.1q)

PBUS / router capacity 2 x 2 Mbit/sBridges up to 7Module width 1ETHUBInterface type Ethernet 10/100BaseTNumber of interfaces 5Module width 1LEMU6(see HDSL Modules) (see HDSL Modules)

DATA MODULES

GECOD 64 kBit/s G.703 codirectionalITU-T recommendation G.703Bit rate 64 kBit/s codirectionalNumber of interfaces 8Module width 1UNIDA 431 Data interfaces n x 64 kBit/sInterface type V.24 / V.28, RS232 Bitrate 0..0.3 kBit/s transp (V.110)

48, 56, n x 64 kBit/s (n=1..4) synch (V.110)Options 1+1,

Subrate multiplexing, Point-Multipoint

Number of interfaces 4Module width 1UNIDA 432 Data interfaces n x 64 kBit/sInterface type V.35Bitrate 0.6..38.4 synch / asynch (V.110)

48, 56, n x 64 kBit/s (n=1..31) synch (V.110)Options 1+1,

Subrate multiplexing, Point-Multipoint, Performance monitoring

Number of interfaces 4Module width 1UNIDA 433 Data interfaces n x 64 kBit/sInterface type X.24 / V.11Bitrate 0.6..38.4 synch / asynch (X.30)

48, 56, n x 64 kBit/s (n=1..31) synch (X.30)Options 1+1,

Subrate multiplexing, Point-Multipoint, Performance monitoring

Number of interfaces 4Module width 1UNIDA 434 Data interfaces n x 64 kBit/sInterface type V.36 RS-449Bitrate 0.6..38.4 synch / asynch (V.110)

48, 56, n x 64 kBit/s (n=1..31) synch (V.110)Options 1+1,

Subrate multiplexing, Point-Multipoint, Performance monitoring

Number of interfaces 2Module width 1UNIDA 435 Data interfaces n x 64 kBit/sInterface type V.36 RS-449Bitrate (circuits 140,141,142 not supported -> use UNIDA434)

0.6..38.4 synch / asynch (V.110) 48, 56, n x 64 kBit/s (n=1..31) synch (V.110)

Options 1+1, Subrate multiplexing, Point-Multipoint, Performance monitoring

Number of interfaces 4Module width 1UNIDA 436Interface type X.24 / V.11Bitrate 0.6..38.4 synch / asynch (X.30)

48, 56, n x 64 kBit/s (n=1..31) synch (X.30)Options 1+1,

Point-Multipoint, Performance monitoring

Number of interfaces 4Module width 1UNIDA 437Interface type V.35Bitrate 0.6..38.4 synch / asynch (V.110)

48, 56, n x 64 kBit/s (n=1..31) synch (V.110)Options 1+1,

Point-Multipoint, Performance monitoring

Number of interfaces 4Module width 1UNIDA 438Interface type X.24 / V.11 (with scrambler)Bitrate 0.6..38.4 synch / asynch (X.30)

48, 56, n x 64 kBit/s (n=1..31) synch (X.30)Options Point-Multipoint, Performance MonitoringNumber of interfaces 4Module width 1

DATA MODULES (continued)

SULIC NTU Baseband modem Interface type: V.24 / V.28 0.6..38.4 kBit/s synch / asynch

X.21 0.6..38.4 kBit/s asynch 0.6..128 kBit/s synch V.35 0.6..38.4 kBit/s asynch 0.6..128 kBit/s synch

NTU remote Power Supply 48 V or 96 VNumber of interfaces: SULIC: 8 x NTU 1Dimensions Aluminium Housing 254 x 196 x 42 mm Plastic Housing 165 x 162 x 35 mm

ISDN MODULES

EXLICTransmission code 2B1QNumber of timeslots per subscriber 2.5NT-1 remote power supply 96 VNumber of Uk0 interfaces 8Module width 1ISBUQ ISDN Basic access U interface 2B1QNumber of U interfaces 8

Line code 2B1QPower feeding of NT1 SupportedInteroperation with EXLIC Not supportedInteroperation with PCON<X> SupportedLeased lines (ISBUQ-ISBUQ) Not supportedModule width 1ISBUTNumber of U interfaces 8Line code 4B3TPower feeding of NT1 SupportedInteroperation with PCON<X> SupportedLeased lines (ISBUT-ISBUT) SupportedModule width 1SULISTransmission code 2B1QNumber of timeslots per subscriber 2.5NT-1 remote power supply 96 VNumber of Uk0 interfaces 8Module width 1

TELEPROTECTION MODULES

OTERM Optical interfaceInterface type Complies to IEC 60870-5-1

Format F1.2 NSD570, NSD70D, FOX6+, FOX20 REL316, REL551, REL561, etc.

Number of interfaces 1 Optical (1300 nm) 1 RS232 (FOX6+ compatible)

Optical code MCMIModule width 1TEBIT Teleprotection interfaceTeleprotection Complies to IEC 60834 -1Voltage range 24..250 VDC Propagation delay time Typ. 3.5 ms (optimised for speed, 24..125 V)1+1 switch over time Typ. 3.5 msNumber of interfaces 4 independent commands

BinaryVoltage range 24..60 VDCNumber of interfaces 8 Binary contactsIEC standard Complies to IEC 60834 -3 Module width 1

ELEMENT MANAGER

ATM MODULES FOX 515 offers also ATM functionality. Please contact ABB for more details about ATM features on the FOX platform.

UCSTUCST Element manager for local as well as remote

configuration of FOX-U and FOX 515Supported platforms UCST R5: Windows 98, NT, ME & 2000Supported NE FOX 515, FOX 512, FOX-U, FOX-U/M

NETWORK MANAGEMENT

UNEMUNEM Network manager with graphical display for element and

networkSupported NE FOX 515, FOX 512, FOX-U, FOX-U/M

We reserve all rights in this document and in the information contained therein. This system overview does neither claim completeness nor availability of modules or functions and ABB reserves the right to insert, postpone or remove modules and functions without further notice.Reproduction, use or disclosure to third parties without express authority is strictly forbidden. © ABB Switzerland Ltd, Utility Automation; 2004

www.abb.com/utilitycommunications

Abbreviations

CAP Carrierless Amplitude and PhaseCMI Code Mark InversionDSL Digital Subscriber LineDXC Digital Cross ConnectECC Embedded Communication ChannelGbE Gigabit EthernetGFP Generic Framing ProcedureHDSL High Bitrate Data Subscriber LineLCAS Link Capacity Adjustment SchemeLTP Line Trail ProtectionMCAS Mercury Channel Associated SignallingMCMI Multi Code Mark InversionMIB Management Information BaseMSP Multiplex Section ProtectionNA Non Urgent AlarmNE Network ElementOHC Overhaed ChannelOSPF Open Shortest Path FirstPDH Plesichronous Digital HierarchySDH Synchronous Digital HierarchySETS Synchronous Equipment Timing SourceSFP Small Form-factor PlugableSNCP Sub-Network Connection ProtectionSTM Synchronous Transport ModuleUA Urgent AlarmVC Virtual Container