DRAWING TITLE DRAWING NUMBER FP000 DRAWING SCHEDULE DATE ISSUE FIRE PROTECTION COVER SHEET FIRE PROTECTION COVER SHEET KCB LEG KCB FP000 Drawing Number: Date: 02/19/2021 Drawing Title: Approved: Checked: Drawn: Drawing Set: Project Name: No. Date Revisions Scale: Job Number: 80% CDs Notes: 1002 West 9th Avenue, King of Prussia, PA 19406 610-989-3800 - www.cvmprofessional.com MECHANICAL ENGINEER CHESTNUT ENGINEERING 2 E Lancaster Ave, 2nd Flr., Ardmore, PA 19003 610-642-1750 CIVIL ENGINEER/SURVEYOR NORTH COUNTRY ENGINEERING, INC. 706 Chippewa Square, Suite 102 Marquette, MI 49855 906-226-7683 Seal: PROJECT MANAGER, LEAD DESIGNER, STRUCTURAL ENGINEER UPS MARQUETTE ARCHITECT TPD ARCHITECTS, LLC 109 Hewett Road Wyncote, PA 19095 215-887-2460 FIRE PROTECTION GROUND FLOOR PLAN FP100 FIRE PROTECTION LEGEND PRE-ACTION FIRE PROTECTION PIPING DRY PIPE FIRE PROTECTION PIPING FIRE DEPARTMENT HOSE CONNECTION FIRE PUMP/FIRE PROTECTION PIPING TOTAL DEVELOPED HEAD(DYNAMIC) PC PLUMBING CONTRACTOR VIF TYP (R) TDH (RL) RPM PRV PSI REVOLUTIONS PER MINUTE EXISTING TO BE RELOCATED EXISTING TO BE REMOVED POUNDS PER SQUARE INCH PRESSURE REDUCING VALVE VERIFY IN FIELD TYPICAL GC PA NTS NO NIC N/A NC SW MIN MAX MC JP HP DP FDHC FP FD DWG (E) EX CLG CONT DN AFF AP JOCKEY PUMP GENERAL CONTRACTOR SAFEWASTE NOT TO SCALE NOT IN CONTRACT NOT APPLICABLE MECHANICAL CONTRACTOR EXISTING TO REMAIN ABOVE FINISHED FLOOR ACCESS PANEL FLOOR DRAIN HORSE POWER NORMALLY OPEN NORMALLY CLOSED CONTINUED MINIMUM MAXIMUM DRAWING EXISTING CEILING DOWN ABBREVIATIONS PIPE ANCHOR PIPE GUIDE GATE VALVE W/ TAMPER SWITCH EXISTING TO BE RELOCATED CAP (RL) UNION PIPE DROP PIPE DOWN PIPE UP D E EXISTING TO BE REMOVED EXISTING TO REMAIN EXISTING TO BE REMOVED EXISTING TO REMAIN CUT AND CAP CONNECT NEW TO EXISTING (R) (E) NEW WORK CONCEALED PENDANT HEAD EXPOSED PENDANT HEAD RECESSED PENDANT SIDEWALL SPRINKLER HEAD FIRE DEPARTMENT SIAMESE CONNECTION FIRE PUMP TEST CONNECTION EXTENDED COVERAGE UPRIGHT HEAD STANDPIPE HOSE CONNECTION UPRIGHT SPRINKLER HEAD DRY UPRIGHT SPRINKLER HEAD FLOW SWITCH BALL VALVE W/ TAMPER SWITCH BUTTERFLY VALVE W/ TAMPER SWITCH PRESSURE GAGE W/ BALL VALVE DOUBLE CHECK VALVE CHECK VALVE VERTICAL VALVE SYMBOLS T T B F (N) NEW WORK (TYPICAL FOR OTHER HEAD TYPES) (TYPICAL FOR OTHER HEAD TYPES) AHJ AUTHORITY HAVING JURISDICTION DSP DRY STANDPIPE GENERAL FIRE PROTECTION REQUIREMENTS: 1. FURNISH ALL EQUIPMENT, MATERIALS, AND LABOR NECESSARY FOR A COMPLETE FIRE SUPPRESSION SYSTEM. 2. INSTALLATION SHALL MEET NFPA AND ALL LOCAL REQUIREMENTS. 3. TEST ALL FIRE PROTECTION PIPING INSTALLED UNDER THIS CONTRACT IN ACCORDANCE WITH NFPA #13. CORRECT AND RETEST ALL LEAKS. TAKE ALL NECESSARY PRECAUTIONS TO PREVENT FREEZING AND ANY DAMAGE TO EQUIPMENT AND PIPING. ALL TESTS WILL BE WITNESSED BY THE OWNERS REPRESENTATIVE AND BUILDING AND FIRE DEPARTMENT INSPECTORS. PROVIDE CONTRACTOR'S MATERIAL AND TEST CERTIFICATE TO OWNER. 4. CONTRACTOR SHALL HAVE "START WORK" PERMIT IN HAND FORM THE AHJ PRIOR TO FABRICATION OR INSTALLATION OF ANY PART OF THE SYSTEM. SPRINKLER NOTES: 1. ALL PIPE TO BE SCHEDULE 40 BLACK STEEL PIPE MEETING OR EXCEEDING ASTM A-135 REQUIREMENTS. 2. ALL SCREW FITTINGS TO BE CAST IRON AND OR MALLEABLE IRON MEETING OR EXCEEDING ANSI B16.4 AND ANSI B16.3. 3. ALL GROOVED (ROLLED ONLY, NO CUT GROOVES) FITTINGS TO BE MALLEABLE IRON MEETING OR EXCEEDING ASTM A-536 REQUIREMENTS. 4. ALL HANGERS TO MEET OR EXCEED NFPA PAMPHLET REQUIREMENTS. SPRINKLER SCHEDULE SYMBOL TYPE MANUFACTURER MODEL # K FACTOR ORIFICE THE VIKING CORPORATION OR EQUAL CONCEALED PENDENT MODEL SIN VK 462 5.6 1/2" FINISH WHITE FACTORY PAINTED COVER THE VIKING CORPORATION OR EQUAL UPRIGHT NATURAL BRASS TAMPER SWITCH STEEL PIPE THREADED LIGHTWALL NOMINAL PIPE STEEL PIPE EXCEPT THREADED LIGHTWALL MAXIMUM DISTANCE BETWEEN HANGERS 12-0 12-0 SIZE (in.) 1" N/A N/A 15-0 12-0 12-0 12-0 2" 15-0 12-0 15-0 12-0 6" 15-0 N/A 15-0 N/A 15-0 N/A 3" 15-0 12-0 5" 4" 15-0 N/A 8" 15-0 N/A 3/4" 1 1/4" 1 1/2" 2 1/2" 3 1/2" LIGHT HAZARD ORDINARY HAZARD Protection Area ft Spacing (max.) ft 2 Spacing (max.) ft Protection Area ft CONSTRUCTION TYPE Noncombustible obstructed and unobstructed and combustible unobstructed 225 15 130 15 168 15 130 15 Combustible obstructed Note: For hydraulically calculated systems only. Protection Areas and Maximum Spacing (Standard Spray Upright/Standard Spray Pendent) 2 SPRINKLER NOTES: 1. ALL SCREW FITTINGS TO BE CAST IRON AND OR MALLEABLE IRON MEETING OR EXCEEDING ANSI B16.4 AND ANSI B16.3. 2. ALL GROOVED FITTINGS TO BE MALLEABLE IRON MEETING OR EXCEEDING ASTM A-536 REQUIREMENTS. 3. ALL HANGERS TO MEET OR EXCEED NFPA PAMPHLET REQUIREMENTS. SYSTEM PIPE SIZE LOCATION SCHEDULE OR TYPE MATERIAL FITTING JOINT BLACK STEEL GROOVED ABOVE GRADE BLACK STEEL VICTAULIC SCH 10 2-1/2" AND ABOVE FIRE PROTECTION PIPE & FITTING SCHEDULE BLACK STEEL THREADED ABOVE GRADE BLACK STEEL THREADED SCH 40 WET LESS THAN 2-1/2" WET 02/05/2021 30% CDs FP000 1 SCALE: NONE FIRE PROTECTION SERVICE RISER SCHEMATIC TO SPRINKLER SYSTEM DRAIN PIPE TO EXTERIOR FP SERVICE. REFER TO CIVIL DWGS FOR CONTINUATION PRESSURE GAGE (TYP) ALARM CHECK VALVE OS&Y GATE VALVE WITH TAMPER SWITCH FLOW SWITCH FLOOR EXTERIOR EXTERIOR POST INDICATOR END OF REMOTE BRANCH LINE OR MAIN PITCH GRADE FINISHED FLOOR FP000 2 SCALE: NONE INSPECTORS TEST CONNECTION DETAIL 45° ELBOW SIGHTGLASS WITH SMOOTH BORE, CORRSOION RESISTANT ORIFICE EQUAL TO THE FLOW ON ONE SPRINKLER VALVE (NORMALLY CLOSED) EXTERIOR WALL WALL PENETRATION AND SLEEVE SPLASH GUARD 7'-0" MAX AFF 02/19/2021 80% CDs

FP000 - mqtbx.org

  • Upload
    others

  • View
    1

  • Download
    0

Embed Size (px)

Citation preview

DRAWING TITLE

DRAWING

NUMBER

FP000

DRAWING SCHEDULE

DA

TE

IS

SU

E

FIRE PROTECTION COVER SHEET

FIRE PROTECTION

COVER SHEET

KCB

LEG

KCB

FP000

Drawing Number:

Date: 02/19/2021

Drawing Title:

Approved:

Checked:

Drawn:

Drawing Set:

Project Name:

No. Date Revisions

Scale:

Job Number:

80% CDs

Notes:

1002 West 9th Avenue, King of Prussia, PA 19406610-989-3800 - www.cvmprofessional.com

MECHANICAL ENGINEER

CHESTNUT ENGINEERING

2 E Lancaster Ave, 2nd Flr.,

Ardmore, PA 19003

610-642-1750

CIVIL ENGINEER/SURVEYOR

NORTH COUNTRY ENGINEERING, INC.

706 Chippewa Square, Suite 102

Marquette, MI 49855

906-226-7683

Seal:

PROJECT MANAGER, LEAD DESIGNER,

STRUCTURAL ENGINEER

UPS MARQUETTE

ARCHITECT

TPD ARCHITECTS, LLC

109 Hewett Road

Wyncote, PA 19095

215-887-2460

FIRE PROTECTION GROUND FLOOR PLANFP100

FIRE PROTECTION LEGEND

PRE-ACTION FIRE PROTECTION PIPING

DRY PIPE FIRE PROTECTION PIPING

FIRE DEPARTMENT HOSE CONNECTION

FIRE PUMP/FIRE PROTECTION PIPING

TOTAL DEVELOPED HEAD(DYNAMIC)

PC PLUMBING CONTRACTOR

VIF

TYP

(R)

TDH

(RL)

RPM

PRV

PSI

REVOLUTIONS PER MINUTE

EXISTING TO BE RELOCATED

EXISTING TO BE REMOVED

POUNDS PER SQUARE INCH

PRESSURE REDUCING VALVE

VERIFY IN FIELD

TYPICAL

GC

PA

NTS

NO

NIC

N/A

NC

SW

MIN

MAX

MC

JP

HP

DP

FDHC

FP

FD

DWG

(E)

EX

CLG

CONT

DN

AFF

AP

JOCKEY PUMP

GENERAL CONTRACTOR

SAFEWASTE

NOT TO SCALE

NOT IN CONTRACT

NOT APPLICABLE

MECHANICAL CONTRACTOR

EXISTING TO REMAIN

ABOVE FINISHED FLOOR

ACCESS PANEL

FLOOR DRAIN

HORSE POWER

NORMALLY OPEN

NORMALLY CLOSED

CONTINUED

MINIMUM

MAXIMUM

DRAWING

EXISTING

CEILING

DOWN

ABBREVIATIONS

PIPE ANCHOR

PIPE GUIDE

GATE VALVE W/ TAMPER SWITCH

EXISTING TO BE RELOCATED

CAP

(RL)

UNION

PIPE DROP

PIPE DOWN

PIPE UP

D

E

EXISTING TO BE REMOVED

EXISTING TO REMAIN

EXISTING TO BE REMOVED

EXISTING TO REMAIN

CUT AND CAP

CONNECT NEW TO EXISTING

(R)

(E)

NEW WORK

CONCEALED PENDANT HEAD

EXPOSED PENDANT HEAD

RECESSED PENDANT

SIDEWALL SPRINKLER HEAD

FIRE DEPARTMENT SIAMESE CONNECTION

FIRE PUMP TEST CONNECTION

EXTENDED COVERAGE UPRIGHT HEAD

STANDPIPE HOSE CONNECTION

UPRIGHT SPRINKLER HEAD

DRY UPRIGHT SPRINKLER HEAD

FLOW SWITCH

BALL VALVE W/ TAMPER SWITCH

BUTTERFLY VALVE W/ TAMPER SWITCH

PRESSURE GAGE W/ BALL VALVE

DOUBLE CHECK VALVE

CHECK VALVE

VERTICAL VALVE

SYMBOLS

T

T

B

F

(N) NEW WORK

(TYPICAL FOR OTHER HEAD TYPES)

(TYPICAL FOR OTHER HEAD TYPES)

AHJ AUTHORITY HAVING JURISDICTION

DSP DRY STANDPIPE

GENERAL FIRE PROTECTION REQUIREMENTS:

1. FURNISH ALL EQUIPMENT, MATERIALS, AND LABOR NECESSARY

FOR A COMPLETE FIRE SUPPRESSION SYSTEM.

2. INSTALLATION SHALL MEET NFPA AND ALL LOCAL REQUIREMENTS.

3. TEST ALL FIRE PROTECTION PIPING INSTALLED UNDER THIS

CONTRACT IN ACCORDANCE WITH NFPA #13. CORRECT AND

RETEST ALL LEAKS. TAKE ALL NECESSARY PRECAUTIONS TO

PREVENT FREEZING AND ANY DAMAGE TO EQUIPMENT AND

PIPING. ALL TESTS WILL BE WITNESSED BY THE OWNERS

REPRESENTATIVE AND BUILDING AND FIRE DEPARTMENT

INSPECTORS. PROVIDE CONTRACTOR'S MATERIAL AND TEST

CERTIFICATE TO OWNER.

4. CONTRACTOR SHALL HAVE "START WORK" PERMIT IN HAND FORM

THE AHJ PRIOR TO FABRICATION OR INSTALLATION OF ANY PART

OF THE SYSTEM.

SPRINKLER NOTES:

1. ALL PIPE TO BE SCHEDULE 40 BLACK STEEL PIPE MEETING OR

EXCEEDING ASTM A-135 REQUIREMENTS.

2. ALL SCREW FITTINGS TO BE CAST IRON AND OR MALLEABLE IRON

MEETING OR EXCEEDING ANSI B16.4 AND ANSI B16.3.

3. ALL GROOVED (ROLLED ONLY, NO CUT GROOVES) FITTINGS TO BE

MALLEABLE IRON MEETING OR EXCEEDING ASTM A-536

REQUIREMENTS.

4. ALL HANGERS TO MEET OR EXCEED NFPA PAMPHLET REQUIREMENTS.

SPRINKLER SCHEDULE

SYMBOL TYPE MANUFACTURER MODEL # K FACTOR ORIFICE

THE VIKING

CORPORATION

OR EQUAL

CONCEALED

PENDENT

MODEL

SIN VK 462

5.6 1/2"

FINISH

WHITE FACTORY

PAINTED COVER

THE VIKING

CORPORATION

OR EQUAL

UPRIGHT

NATURAL BRASS

TAMPER SWITCH

STEEL PIPE

THREADED LIGHTWALL

NOMINAL PIPE

STEEL PIPE EXCEPT

THREADED LIGHTWALL

MAXIMUM DISTANCE BETWEEN HANGERS

12-0

12-0

SIZE (in.)

1"

N/A

N/A

15-0

12-0

12-0

12-0

2"

15-0

12-0

15-0

12-0

6"

15-0

N/A

15-0

N/A

15-0

N/A

3"

15-0

12-0

5"4"

15-0

N/A

8"

15-0

N/A

3/4" 1 1/4" 1 1/2" 2 1/2" 3 1/2"

LIGHT HAZARD ORDINARY HAZARD

Protection

Area

ft

Spacing

(max.)

ft

2

Spacing

(max.)

ft

Protection

Area

ft

CONSTRUCTION

TYPE

Noncombustible

obstructed and

unobstructed and

combustible

unobstructed

225 15 130 15

168 15 130 15

Combustible

obstructed

Note: For hydraulically calculated systems only.

Protection Areas and Maximum Spacing

(Standard Spray Upright/Standard Spray Pendent)

2

SPRINKLER NOTES:

1. ALL SCREW FITTINGS TO BE CAST IRON AND OR MALLEABLE IRON

MEETING OR EXCEEDING ANSI B16.4 AND ANSI B16.3.

2. ALL GROOVED FITTINGS TO BE MALLEABLE IRON MEETING OR

EXCEEDING ASTM A-536 REQUIREMENTS.

3. ALL HANGERS TO MEET OR EXCEED NFPA PAMPHLET REQUIREMENTS.

SYSTEM PIPE SIZE LOCATION SCHEDULE OR TYPEMATERIAL FITTING JOINT

BLACK STEEL GROOVEDABOVE GRADE BLACK STEEL VICTAULICSCH 10

2-1/2" AND

ABOVE

FIRE PROTECTION PIPE & FITTING SCHEDULE

BLACK STEEL THREADEDABOVE GRADE

BLACK STEEL THREADED

SCH 40WET

LESS THAN

2-1/2"

WET

02/05/2021

30%

C

Ds

FP000

1

SCALE: NONE

FIRE PROTECTION SERVICE RISER SCHEMATIC

TO SPRINKLER

SYSTEM

DRAIN PIPE TO EXTERIOR

FP SERVICE.

REFER TO CIVIL DWGS FOR

CONTINUATION

PRESSURE GAGE (TYP)

ALARM CHECK VALVE

OS&Y GATE VALVE WITH

TAMPER SWITCH

FLOW SWITCH

FLOOREXTERIOR

EXTERIOR POST

INDICATOR

END OF REMOTE

BRANCH LINE OR MAIN

PITCH

GRADEFINISHED FLOOR

FP000

2

SCALE: NONE

INSPECTORS TEST CONNECTION DETAIL

45° ELBOW

SIGHTGLASS WITH SMOOTH

BORE, CORRSOION RESISTANT

ORIFICE EQUAL TO THE FLOW

ON ONE SPRINKLER

VALVE (NORMALLY CLOSED)

EXTERIOR WALL

WALL PENETRATION

AND SLEEVE

SPLASH GUARD

7'-0" MAX AFF

02/19/2021

80%

C

Ds

AutoCAD SHX Text
T
AutoCAD SHX Text
T
AutoCAD SHX Text
F
AutoCAD SHX Text
T

GENERAL NEW WORK NOTES:

1. ALL WAREHOUSE AREAS ARE CLASSIFIED AS ORDINARY

HAZARD GROUP 2 (0.3 GPM/SF OVER 2500 SF, AS REQUIRED

BY UPS). ALL OFFICES AREAS ARE CLASSIFIED AS LIGHT

HAZARD (0.15 GPM/SF OVER 1500 SF, AS REQUIRED BY UPS)

2. HEADS IN AUTO SHOP SHALL PROTECT A MAXIMUM OF 70 SF

PER UPS STANDARDS.

3. NEW HEAD LOCATIONS AND PIPE ROUTING SHALL BE

COORDINATED WITH LIGHTING AND STRUCTURE.

4. PIPE SIZES ARE SHOWN FOR COORDINATION ONLY. ALL

SIZES SHALL BE DETERMINE BY FPC THROUGH HYDRAULIC

CALCULATIONS.

5. ALL HEADS AND PIPING REQUIRED BELOW CONVEYORS

WILL BE PROVIDED BY OTHERS.

6. A MUNICIPAL WATER SERVICE IS NOT AVAILABLE ON SITE.

ALL FIRE PROTECTION WATER WILL COME FROM THE ON

SITE STORAGE TANK.

PUMP HOUSE

WELL

100,000 GALLON, INSULATED,

GROUND LEVEL SUCTION FIRE

PROTECTION STORAGE TANK

SCREENED VENT AT

TOP OF TANK

4" OVERFLOW PIPE

EXTERNAL LADDER

HATCH COVER (MIN 24")

INTERNAL LADDER

SAFETY CAGE

LADDER SECURITY COVER

WATER LEVEL INDICATOR

1-1/2" EMERGENCY DRAIN VALVE

LISTED RENEWABLE-DISC

GLOBE VALVE

10 KW ELECTRIC

TANK HEATER

TANK HEATER

CIRCULATION PUMP

2-1/2" HOT WATER

CIRCULATION PIPE

BURIED FP TO

BUILDING.

REFER TO CIVIL

DWGS FOR CONT.

ANTI-VORTEX PLATE

AND FITTING

ACCESSIBLE

CONCRETE PIT

BELOW FROST LINE

FIRE PUMP DIESEL

STORAGE TANK

DIESEL

FIRE PUMP

JOCKEY PUMP

VENT

FILL LINE

10987654321

E E

B B

A

D D

C C

7.5 8.3

7.3 8.5

6" FP SERVICE. REFER TO CIVIL

DWGS FOR CONTINUATION

ZONE RISER

F

T

INSPECTORS TEST

CONNECTION

T

POST INDICATOR VALVE

REFER TO

MEZZANINE PLAN FOR

CONTINUATION (TYP)

SYSTEM DRAIN

1098

B

A

8.5

B.8

8.1

202

TSG STORAGE

ROOM

200

MECHANICAL

AREA

201

SERVER

ROOM

FIRE PROTECTION

GROUND FLOOR

PLAN

KCB

LEG

KCB

FP100

Drawing Number:

Date: 02/19/2021

Drawing Title:

Approved:

Checked:

Drawn:

Drawing Set:

Project Name:

No. Date Revisions

Scale:

Job Number:

80% CDs

Notes:

1002 West 9th Avenue, King of Prussia, PA 19406610-989-3800 - www.cvmprofessional.com

MECHANICAL ENGINEER

CHESTNUT ENGINEERING

2 E Lancaster Ave, 2nd Flr.,

Ardmore, PA 19003

610-642-1750

CIVIL ENGINEER/SURVEYOR

NORTH COUNTRY ENGINEERING, INC.

706 Chippewa Square, Suite 102

Marquette, MI 49855

906-226-7683

Seal:

PROJECT MANAGER, LEAD DESIGNER,

STRUCTURAL ENGINEER

UPS MARQUETTE

ARCHITECT

TPD ARCHITECTS, LLC

109 Hewett Road

Wyncote, PA 19095

215-887-2460

FP100

1

SCALE: 1/8" = 1' - 0"

FIRE PROTECTION GROUND FLOOR PLAN

FP100

3

SCALE: 1/4" = 1' - 0"

FIRE PROTECTION PUMP HOUSE PLAN

FP100

2

SCALE: 1/8" = 1' - 0"

FIRE PROTECTION MEZZANINE PLAN