Fresh AirBreathe easy
Air ConditionersResidential and commercial
R410 a
R410 a
2
1 2 3 4 5 6 7 8 9 10
Product and Production
Quality Management
ISO 9001 & ISO14001 certified. Strategic partnership with UL since 2002 Five laboratories awarded WTDP by UL since 2002 Strategic partnership with TUV and LGA ITS
RoHS Compliance Scheme Awarded 6 Sigma Implementation
Comfort
Fresco Tech
1 Silver Ion Filter
Silver Ions kill bacteria and prevent bacterial activity.
2 Cold Catalyst Filter
Eliminates formaldehyde and other volatile organic compounds (VOCs) as well as harmful gasses and odours.
3 Vitamin C Filter
The Vitamin C filter fills the air with vitamin C, which softens the skin and reduces stress.
4 Bio Filter
Contains specialised biological enzymes and HEPA. It filters out small dust particles, bacteria, fungi and microbes, eliminating bacteria by dissolving their cell walls.
5 Compound Filter
Combines the functions of two or three different filters to meet various needs simultaneously.
6 3M HAF Filter
This open hole structure is charged electrostatically to ensure maximum air flow and minimum pressure drops.
7 Negative Ion Filter
Releases negative ions to purify the air, and sterilise bacteria, reducing tiredness.
8 Plasma Dust Collector
Generates a high voltage electrostatic zone, to absorb and eliminate dust, smoke and pollen particles.
9 10 Super Ionizer & Ionizer
Releases negative ions, eliminate odours, dust, smoke and pollen particles to give you fresh and healthy air.
Airco Branded Products
The Airco brand dates back to 1949 when it was first launched into the local market. This brand has always been used to supply OEM products from some of the best comfort solutions manufacturers in the world. Today this proud tradition continues as the brand was re established and is currently extensively utilised on various comfort product ranges. Only the best producers of these respective ranges are selected to supply our brand into the market.
3
Features
Reliability
Heating Belt (Outdoor) (Optional on certain models)
With a PTC heating belt fitted onto the base plate of the outdoor unit, accumlated rain, snow or defrosted water is avoided.
Anti-Rust Cabinet The cabinet is treated to eliminate rust.
Powerful Dehumidification Automatically adjusts humidity to a suitable level when in operation.
Self-Diagnosis Function If abnormal operations or part failures, are detected, the microcomputer of the unit will automatically switch off to protect the system. The error or protection code will be displayed on the indoor unit.
Low Ambient Cooling If the unit has a Low Ambient Kit installed it can operate in temperatures as low as -15ºC for cooling.
Bluefin Coils Bluefin Coils are offered on all outdoors.
Valve Protection Cover This cover protects the valves during transportation. It also prevents the condensed water on the valve from dripping.
Two Speed Outdoor Fan Motor With a two speed outdoor fan motor, the temperature ranges of the outdoor unit are increased in both heating and cooling operations.
Refrigerant Leakage Detection When the outdoor unit detects a refrigerant leak, the indoor unit will alarm.
Gold Fin (Optional on certain models)
The Gold hydrophilic condenser improves heating efficiency by accelerating the defrosting process. The unique anticorrosive golden coating on the condenser can withstand salty air, rain and other corrosive elements.
Health
Silver Ion Filter Silver Ions kill bacteria and prevent their activity.
Cold Catalyst Filter Eliminates formaldehyde and other volatile organic compounds (VOCs) as well as harmful gasses and odours.
Vitamin C Filter (Optional on certain models)
The Vitamin C filter fills the air with vitamin C, which softens the skin and reduces stress. The lifetime of the Vitamin C filter is approximately two years.
Bio Filter The Bio Filter consists of a specialised biological enzymes and an Eco Filter. The Eco Filter catches very small airborne dust particles and neurilities bacteria, fungi and microbes. Biological enzymes kill bacteria by dissolving their cell walls thus eliminating the problem of re-pollution.
Compound Filter Combines functions of two or three different filters to meet various needs simultaneously.
3M HAF Filter This open hole structure is charged electrostatically to ensure maximum air flow and minimum pressure drops.
Negative Ion Filter Releases negative ions which purifies air, sterilises bacteria and reduces tiredness.
Plasma Dust Collector The Plasma Dust Collector generates a high voltage electrostatic field. The air passing through this zone is converted to plasma, and 95% of the dust, smoke and pollen particles are attracted to the electrostatic filter.
Super Ionizer & Ionizer Releases negative ions, eliminates odours, dust, smoke and pollen particles giving you fresh and healthy air.
Fresh Air Fresh air intake makes air quality healthier and more comfortable.
Self-Cleaning When this function is activated, the indoor unit operates in fan-only mode with a low fan speed. During this period the condensed water will remove the dust on the evaporator fins. The unit then turns to heating mode with a low fan speed which dries the inside of indoor unit. Finally it turns to fan-only mode and blows away the wet air. The whole process cleans the inside of indoor unit preventing the breeding of bacteria.
Energy Saving
Multi-Bend Evaporator Within the confined space of the indoor unit, the multi-bend evaporator helps increase the heat exchange surface for improved efficiency.
Sleep Mode Sleep Mode automatically increases (cooling) or decreases (heating) at 1°C per hour for the first two hours, then holds steady for the next 5 hours, after that it will switch off. This characteristic is energy saving and increases comfort during operation at night.
Intelligent Eye Detector (Optional on certain models)
With the built-in infrared sensor, the indoor unit detects human movement. The unit will turn off 30 minutes after you have left the room and automatically switch on when you return, helping save energy.
lW Standby Intelligent on-off technology enables Airco products to automatically enter energy-saving mode when on standby, cutting energy consumption from 4-5W to 1W which accounts to a 5O% saving on the indoor operation.
4
Comfort
8°C Heating In heating operation, the pre-set temperature of the air conditioner can be as low as 8ºC, which keeps the room temperature steady at 8ºC for in winter.
Follow Me (Optional on certain models)
A temperature sensor is built into the remote control. When you are close to the remote control, the unit will automatically change the setting on the unit to ensure comfortable temperature just like the air conditioner is following you.
Anti-Cold-Air (Heat Pump Only) On starting up the unit, the fan speed is regulated automatically from the lowest setting to the preset level, according to the temperature in the evaporator. This function prevents cold air blowing out at the beginning of the operation, avoiding discomfort.
Horizontal & Vertical Auto Swing The design of the large louvres, with a wide swing angle range, guides the cool or warm air to every corner of the room.
Independent Dehumidification The individual dehumidification mode dehumidifies the room efficiently, but does not lower the temperature as significantly as cooling operation.
Turbo Operation This function maximises the heating or cooling output, resulting in a rapid response to temperature change.
360º Air Flow Panel The 360° air outlet makes equal, fast and wide-range cooling possible.
Low Noise Airflow System Without decreasing airflow and capacity, a large diameter cross flow fan can bring down the indoor unit noise level by reducing the fan speed.
Temperature Compensation Different installation heights effects the temperature picked up by the sensor (on the floor). The installer can change the jumping wire combination on the indoor PCB to compensate for this deviation.
Multi Indoor Fan Speeds With up to 12 indoor fan speeds, more variation in airflow is possible.
Two-Direction Airflow Because the density of cold and warm air varies, in cooling mode the indoor unit blows out horizontally and in heating mode it blows out vertically. This technology makes the room temperature more consistent and comfortable during the operation.
Condensate Disposal Slinger-ring condensate disposal, enhancing cooling performance.
PTC Heater (Optional on certain models)
With a built-in PTC device, the heating operation is more powerful even in extreme cold.
Auto Swing Distributes air to a wider area by moving horizontal flaps automatically.
Super Silent Airflow
With up to 12 indoor fan speeds, a more comfortable air flow is possible.
Multi Indoor Fan Speeds
Technology controls the airflow volume and capacity output and together with the large diameter cross-flow fan the noise level of the indoor unit is lowered.
0.5W Standby
Intelligent on-off technology enables Airco products to automatically enter energy-saving mode when on standby. Cutting energy consumption from 5W to 0.5W which amounts to a 90% saving.
Short-cut function
Preset all functions (like temperature, operation mode, fan speed and other). Every time you press the “SHORT CUT” button, the unit will run under the mode that you recorded. You don’t need to reset the parameters after they are adjusted by other users.
Features
5
Features
Convenience
Mono & Multi Compatibility The indoor unit is compatible with both mono and multi inverter systems. This is convenient for warehouse and stock administration.
Louvre Position Memory Function On restarting the unit, the angle of the horizontal louvre automatically moves to the same position as it was previously set at.
Wired Controller (Optional on certain models)
The wired controller can be fixed onto the wall to avoid being misplaced. It is recommended for commercial use.
Washable Filter A washable filter makes it easier to clean.
Auto-Restart If the air conditioner stops due to a power cut, it will automatically restart with the previous function settings.
Convenient Handle Ergonomical handle makes carrying the unit easier and convenient.
Sliding Chassis (Optional on certain models)
The whole refrigerant system can be slided out, which makes installation easier and safer.
Transparent Water Level Indication Clearly shows the water level and indicates when draining is required.
Slim Design The minimised dimensions of the unit, allows for an easier and more flexible installation and improved aesthetics .
Timer The timer can be set to start and stop at any point within a 24 hour period.
Installation Kit (Optional on certain models)
Designed to assit with the installation of the system.
Optional Filter More functional filter choices will enhance the efficiency of the unit.
Built-in Drain Pump Cassettes have a drain pump which can extract up to 750mm of condensed water.
Cleanable Panel The front panel of the indoor unit is easy to detach for cleaning.
2 Way Piping Connection Piping and drainage hoses can be connected on either side of the indoor unit.
Remote Control
Temperature SettingON / OFF
Short Cut FunctionMode Setting AUTO/COOL/DRY/HEAT/FAN
Fan Speed Setting HIGH/MED/LOW/AUTO
Timer Setting
Air Flow SWING/DIRECT
Sleep Mode/Fresh
LED Display / Follow meTurbo / Self Clean
6
Model Code (Nomenclature)
Residential
A S 9A I - 12 H R F N1 - Q D2 F
A Airco
S Unit Type
S Split Wall-mounted P Portable D Dehumidifier W Window F Floor Standing O Outdoor
9A Product Series
11P Premier Series lA Alps Series y Y Series 11M Oasis Series
I Connect Type
I Multi Type
Omit Single Type
12 Capacity
Air Conditioner: Cooling Capacity (xlOOOBtu/h)
Dehumidifier: Moisture Removal Volume (L/day)
H Function Code
C Cooling only H Heat Pump A Heat Pump with Electric Heater E Cooling & Electric Heater
R Control Mode
W Wire Control M Mechanical Control E Electric Control R Remote Control
F Inverter Type
F Full DC Inverter D DC Inverter I AC Inverter Omit ON/OFF
N1 Refirgerant
Nl R410A N2 R407C N3 R134a Omit R22
Q Power Code
Power Supply Q 220-240V~,50Hz, 1Phase R 380-420Vx~, 50Hz, 3Phase S 380V~, 50Hz, 3Phase
D2 EER Code
AO-A9 EER 1.0-1.9 BO-B9 EER 2.0-2.9 C0-C9 EER 3.0-3.9 DO-D9 EER 4.0-4.9
F Function Code
F Ionizer L Low Ambient Kit H Fresh Air Q Quicker Connect W Outdoor Power Supply
Light Commercial (Indoor Unit)
A C D - 24 H R F N1 - Q
A Airco
C Product Category
C Cassette Type T Duct Type H High Static Pressure Duct Type U Ceiling & Floor Type F Console
D Designed Range
A 1st Design B 2nd Design C 3rd Design D 4th Design
24 Capacity
Cooling Capacity (x1000Btu/h)
H Function Code
C Cooling only H Cooling & Heating
R Control Mode
W Wire Control R Remote Control
F Inverter Code
F Full DC Inverter D DC Inverter Omit ON/OFF
N1 Refrigerant
Nl R410A Omit R22
Q Power Code
Power Supply (V-Hz-Ph) Q 220-240V~, 50Hz, 1Phase R 380-420V~, 50Hz, 3Phase
Light Commercial (Outdoor Unit)
A OU B - 36 H F N1 - Q
A Airco
OU Universal Outdoor Unit
O Outdoor Unit U Universal
B Designed Range
A 1st Design B 2nd Design C 3rd Design D 4th Design
36 Capacity
Cooling Capacity (x1000Btu/h)
H Function Code
C Cooling only H Cooling & Heating
F Inverter Type
F Full DC Inverter D DC Inverter Omit ON/OFF
N1 Refrigerant
Nl R410A Omit R22
Q Power Code
Power Supply (V-Hz-Ph) Q 220-240V~,50Hz, 1Phase R 380-420V~,50Hz, 3Phase
7
Product Range
Light Commercial Series ON/OFF
Super Slim Cassette 18K 24K 36K 48K 60K
3rd generation ceiling & floor18K 24K 36K48K 60K
Cassette cover up to 18000 Btm
Duct 12K 18K 24K 30K 36K 48K 60K
High Static Presure Duct 18K 24K 36K48K 60K
Split Series ON/OFF
R 7K 9K 12K 18K 21K 24K, 30K
G 36K
8
Compact Cassette
3600 Air Outlet Panel
3600 air outlet makes equal, fast and wide-range cooling.
Compact Design
The body size of this unit is
570mmx570mmx260mm, and panel
size is 647mmx647mmx50mm.lt can
be installed in one standard ceiling
tile (600Wx600D), which can save
installation time and proVida an ease of
installation.
Fresh Air Intake
Fresh air fulfills air quality healthier and
more comfortable.
E-box Inside
The E-box is simply and safely built
inside the indoor unit. This integrated
design proVidas a more compact body
size and ease of installation. And the
maintenance of the E-box is simple, by
openning the return air grille.
9
Compact Cassette
Specifications – Compact Cassette: Single (ON/OFF)
ACA-12HRN1 ACA-18HRN1
Power supply V-ph-Hz 220~240-1-50 220~240-1-50
Cooling Capacity Btu/h 12000 18000
Input W 1190 2150
Current A 5,45 9,3
EER W/W 2,96 2,45
Heating Capacity Btu/h 13000 19500
Input W 1180 1837
Current A 5,4 8,30
COP W/W 3,23 3,11
Indoor fan motor Model YDK15-6P YDK37-4P
Qty 1 1
Input W 47.1/31.1/26.9 80/65/46
Capacitor uF 1.5UF/450V 2UF/400-450V
Speed(Hi/Med/Lo) r/min 780/540/430 1000/875/710
Indoor coil Number of rows 1 2
Tube pitch(a) x row pitch(b) mm 21×13.37 21×13.37
Fin spacing mm 1,3 1,3
Fin type Hydrophilic aluminum Hydrophilic aluminum
Tube outside dia. & type mm ø7, Inner grooved tube ø7, Inner grooved tube
Coil (LxWxH) mm 1380×210×13.37 1370×210×26.74
Number of circuits 2 4
Indoor air flow (Hi/Mid/Lo) m3/h 680/600/400 800/710/560
Indoor noise level (sound pressure) (Hi/Mid/Lo) dB(A) 41/38/35 44/41/38
Throttle type / /
Indoor unit Dimension (WxDxH)(body) mm 570x570x260 570x570x260
Packing (WxDxH)(body) mm 655x655x290 655x655x290
Dimension (WxDxH)(panel) mm 647x647x50 647x647x50
Packing (WxDxH)(panel) mm 715x715x123 715x715x123
Net/Gross weight(body) kg 16/20 19/21
Net/Gross weight(panel) kg 2.5/4.5 2.5/4.5
Design pressure MPa 4.2/1.5 4.2/1.5
Drainage water pipe diameter mm ODΦ25 ODΦ25
Refrigerant piping Liquid side/Gas side mm ø6.35/ø12.7(1/4"/1/2") ø6.35/ø12.7(1/4"/1/2")
Controller RG51Q/BGE RG51Q/BGE
Operation temperature Cooling ºC 17~32 17~32
Heating ºCΦ 0~30 0~30
Note: 1. The above design and specifications are subject to change without prior notice for product improvemnet.
2. The noise level data reflects the level in an anechoic chamber.
Features
Standard
Auto Defrosting
Auto Restart Function
Anti-Cold Air Function
Air Flow Panel
Sleep Mode
Built-in Drain Pump
Independent Dehumidification
Optional
Wired Controller
Low Ambient Cooling
10
Independent Vane Control
If the airflow direction needs to be
changed as a result of an altered room
layout or due to the mode selected, the
air direction of each vane can be set
independently using the wired remote
controller.
Cassette
Touch Screen Wired Controller (optional)
Standard high-end touch screen wired
controller with failure indication. A
more user friendly interface is possible.
Reserved Remote on-off and Alarm Ports
Optional on certain models
Remote On/Off With the reserved
ports, a remote switch can be easily
connected to realise remote control.
The built in PCB output alarm facility
makes setting up an external alarm
light or gauge possible.
Lifting Easy-Clean & 3600 Air flow Panel
The removeable lifting panel makes the
clean process much easier. And with
the 3600 flow system, distributing
comfort to every corner of the room.
This unit is only 205mm in height, an
improvement over the 230mm height
of the conventional model.Twin Combination
The units can be installed as Twin
systems: one outdoor unit can connect
with two indoor units. The indoor units
can be combined in any of the different
available ratings.
11
Cassette
Specifications – Cassette (ON/OFF)
Model ACA-24HRN1 ACA-36HRN1 ACA-48HRN1 ACA-60HRN1
Power supply V-ph-Hz 220~240-1-50 220~240-1-50 380~420-3-50 380~420-3-50
Cooling Capacity Btu/h 24000 36000 48000 60000
Input W 2475 3970 5515 6685
Current A 12,5 18,17 9,52 11,55
EER W/W 2,87 2,66 2,55 2,63
Heating Capacity Btu/h 26000 40000 49500 60000
Input W 2428 4070 5410 5920
Current A 11,8 19,67 9,34 10,22
COP W/W 3,13 2,88 2,68 2,97
Indoor fan motor Model YDK80-6E YDK90-6E YDK90-6E YDK90-6E
Qty 1 1 1 1
Input w 110/100/90 147/125/110 147/125/110 147/125/110
Capacitor uF 3.5UF/450V 3.5UF/450V 3.5UF/450V 3.5UF/450V
Speed(hi/mi/lo) r/min 670/550/400 770/640/550 770/640/550 770/640/550
Indoor coil Number of rows 2 2 2 3
Tube pitch(a)x row pitch(b) mm 21x13.37 21x13.37 21x13.37 21x13.37
Fin spacing mm 1,5 1,4 1,5 1,5
Fin type (code) Hydrophilic aluminum Hydrophilic aluminium Hydrophilic aluminium Hydrophilic aluminium
Tube outside dia.and type mm ø7,Inner grooved tube ø7,inner grooved tube ø7,inner grooved tube ø7, inner groove tube
Coil (LxWxH) mm 1990×168×26.74 1990x252x26.74 1990x252x26.74 2080x252x40.11
Number of circuits 8 8 12 12
Indoor air flow (Hi/Med/Lo) m3/h 1327/1114/871 1545/1354/1187 1545/1354/1187 1800/1480/1280
Sound level (sound pressure) dB(A) 48/45/39 50/46/42 51/47/43 51/47/42
Throttle type / / / /
Indoor unit Dimension (Wx DxH)(body) mm 840x840x230 840x840x300 840x840x300 840x840x300
Packing (WxDxH)(body) mm 900x900x250 900x900x320 900x900x320 900x900x320
Dimension (WxDxH)(panel) mm 950x950x55 950x950x55 950x950x55 950x950x55
Packing (WxDxH)(panel) mm 1035x1035x90 1035x1035x90 1035x1035x90 1035x1035x90
Net/Gross weight(body) kg 24/30 28/32 28.6/32.6 32/36
Net/Gross weight(panel) kg 5/8 5/8 5/8 5/8
Design pressure MPa 4.2/1.5 4.2/1.5 4.2/1.5 4.2/1.5
Drainage water pipe dia. mm ODø32 ODø32 ODø32 ODø32
Refrigerant piping Liquid side/ Gas side mm ø9.52/ø15.9(3/8"/5/8") ø9.52/ø19(3/8"/3/4") ø9.52/ø19(3/8"/3/4") ø9.52/ø19(3/8"/3/4")
Controller RG51Q1/BGE RG51Q1/BGE RG51Q1/BGE RG51Q1/BGE
Operation temperature Cooling ºC 17~32 17~32 17~32 17~32
Heating ºC 0~30 0~30 0~30 0~30
Note: 1. The above design and specifications are subject to change without prior notice for product improvemnet.
2. The noise level data reflects the level in an anechoic chamber.
Features
Standard
Auto Defrosting
Auto Restart Function
Anti-Cold Air Function
LED Display
Sleep Mode
Slim Design
Fashion Design
Independent Dehumidification
Timer
Wide-angle Air flow
Air Flow Panel
Built-in Drain Pump
Optional
Low Ambient Cooling
Wired Controller
Optional Colour Panels
12
Fresh Air Intake
More than 60% parts and assemblies
(such as fan wheel, plastic cases,
metal parts and etc) are universal for
3 different bodies, which makes the
production and maintenance easier.
3rd generation ceiling & floor
Swing Torsion Angles
3600 air outlet makes equal, fast and
wide-range cooling possible.
Compact Design
Fresh air improves air quality.
Flexible Installation
The unit can be installed horizontally
on the ceiling or vertically against a
wall.
13
3rd generation ceiling & floor
Specifications – Ceiling & Floor (ON/OFF)
Indoor Unit AUE-18HRN1-Q AUE-24HRN1-Q AUE-36HRN1-Q AUE-36HRN1-R AUE-48HRN1-Q AUE-60HRN1-R
Outdoor Unit AOU-18HRN1-Q AOU-24HRN1-Q AOU-36HRN1-Q AOU-36HRN1-R AOU-48HRN1-Q AOUA-60HRN1-R
CapacityCooling Capacity Btu/h 18000 24000 36000 36000 48000 55000
kW 5.3 7.1 10.5 10.5 14.0 16.1
Heating Capacity Btu/h 20000 26000 40000 40000 52000 65000
kW 6.0 7.6 12.0 12.0 15.2 19.1
Electrical partsPower Supply V~, Hz, Ph 220-240, 50, 1 220-240, 50, 1 220-240, 50, 1 380-415, 50, 3 380-41S, 50, 3 380-415, 50, 3
Power Input (kW) Cooling 1726 2423 4180 4180 5360 6370
Heating 1863 2415 3985 3985 4980 6145
PerformanceEER W/W 3.07 2.93 2.51 2.51 2.61 2.51
COP W/W 3.22 3.15 3.01 3.01 3.01 3.01
Air Flow Volume m3/h 1200/1000/900 1200/1000/900 1900/1700/1500 1900/1700/15OO 1900/1700/1500 2500/2100/1800
Noise Level (dB(A)) Hi/Med/Low 51/46/42 51/46/42 53/48/44 53/48/44 53/48/44 54/49/46
Dimension & Weight & Piping SizeNet Dimension (mm) WxHxD 1068x235x675 1068x235x675 1285x235x675 1285x235x675 1285x235x675 1650x235x675
Net Weight kg 22.4 25 29 29 31 39
Packing Dimension (mm) WxHxD 114Sx313x755 1145x313x755 1360x313x755 1360x313x755 1360x313x755 1725x313x755
Gross Weight kg 26.6 30 36 36 36 45
Piping Size (mm) Liquid Ø6.4 Ø9.5 Ø9.5 Ø9.5 Ø9.5 Ø9.5
Gas Ø12.7 Ø15.9 Ø19.0 Ø19.0 Ø19.0 Ø19.0
Drainage ODØ25.00 Ø25.00 Ø25.00 Ø25.00 Ø025 OOØ25
Applicable Area & Stuffing QuantityApplicable Area m2 21-35 28-47 42-70 42-70 S6-93 64-107
Stuffing Quantity (Set) 20’/40’/40’HQ 62/129/151 59/122/143 32/67/79 32/67/79 30/63/74 27/57/67
Note: 1. The above design and specifications are subject to change without prior notice for product improvemnet.
2. The noise level data reflects the level in an anechoic chamber.
14
Duct
Return Air Ways
Air inlet from back standard and from bottom optional. The size of the plate from
bottom and flange from back is the same, it’s easy for installer to change the air
inlet from back to bottom.
Fresh Air
Optional on certain models
Fresh air to introduce ambient air.
Built-in Drain Pump (optional)
The drain pump can lift the condensing
water up to 750mm upmost
Twin Combination
Optional on certain models
The units can be installed as dual systems one outdoor unit can connect with two
indoor units. The indoor units can be combined in any of the different available
ratings.
15
Duct
Specifications – High Static Pressure Duct
AHC-24HWN1 AHC-36HWN1 AHC-48HWN1 AHC-60HWN1
Power supply V- Ph-Hz 220~240-1-50 220~240-1-50 380~420-3-50 380~420-3-50
Cooling Capacity Btu/h 24000 36000 48000 60000
Input W 2830 4010 5800 6630
Current A 13,30 18,35 9,20 9,50
EER W/W 2,5 2,63 2,43 2,65
Heating Capacity Btu/h 26000 39000 52000 65000
Input W 2450 3680 4800 5300
Current A 11,80 16,84 8,20 8,90
COP W/W 3,11 3,11 3,17 3,59
Indoor fan motor Model YDK100-4X-1 YDK200-4F YDK360-4F YSK400-4C
Qty 1 1 1 1
Input W 220/205/190 500/460/345 630/570/435 930/740/592
Capacitor uF/ V 12uF/450V 15uF/370-450V 15uF/370-450V 15uF/370-450V
Speed (Hi/Mid/Lo) r/min 940/900/870 1060/980/820 1210/1135/960 1080/920/790
Indoor coil Number of rows 2 3 4 3
Tube pitch(a)×row
pitch(b)
mm 25.4 x22 25.4x22 25.4x22 25.4x22
Fin spacing mm 1,5 1,6 1,6 1,6
Fin type Hydrophilic aluminium
Tube outside dia. & type mm ø9.52,inner grooved tube
Coil (LxWxH) mm 700x356x44 700x355.6x66 700x355.6x88 996x355.6x66
Number of circuits 3 7 7 7
Indoor air flow (Hi/Med/Lo) (No duct) m3/h 1800/1670/1450 2400/2200/2000 3000/2700/2200 4000/3750/3100
Indoor external static pressure (Hi) Pa 100 150 160 160
Indoor noise level (Hi/Med/Lo) (Under Standard Static dB(A) 48/46/44 56/54/50 58/56/51 57/53/50
Throttle type / / / /
Indoor unit Dimension (W×D×H) mm 856x691x400 856x691x400 856x691x400 1200x691x400
Packing (W×D×H) mm 1090x768x440 1090x768x440 1090x768x440 1436x768x440
Net/Gross weight kg 41/47 47/53.5 52/57 63/70
Design pressure MPa 4.2/1.5 4.2/1.5 4.2/1.5 4.2/1.5
Drainage water pipe dia ODø25 ODø25 ODø25 ODø25
Refrigerant piping Liquid side/ Gas side mm ø9.52ø15.9(3/8"/5/8") ø9.52/ø19(3/8"/3/4") ø9.52/ø19(3/8"/3/4") ø9.52/ø19(3/8"/3/4")
Controller KJR-10B/DP(T)-E KJR-10B/DP(T)-E KJR-10B/DP(T)-E KJR-10B/DP(T)-E
Operation temperature Cooling ºC 17~32 17~32 17~32 17~32
Heating ºC 0~30 0~30 0~30 0~30
Note: 1. The above design and specifications are subject to change without prior notice for product improvemnet.
2. The noise level data reflects the level in an anechoic chamber.
Features
Standard
Anti-Cold Air Function
Auto Restart Function
Auto Defrosting
Timer
Wired Controller
Sleep Mode
Two way drainage
Independent Dehumidification
Optional
Low Ambient Cooling
Built-in Drain Pump
16
Sleep Mode
This function enables the unit to
automatically increase (cooling) or
decrease (heating) 1ºC per hour for the
first two hours, then hold steady for
the next 5 hours, after that the unit
will stop operation. It can maintain the
optimal temperature and save energy
R Series
Turbo Mode
With this function, the air conditioner
will maximize the output of cooling or
heating capacity, make the room cool
down or heat up rapidly, and attain the
desired temperature in the shortest
time.
17
R Series
Specifications – R Series
ASR-09HRN1 ASR-12HRN1 ASR-18HRN1 ASR-24HRN1 ASR-30HRN1 ASG-36HRN1
Power supply Ph-V-Hz 1Ph, 220-240V~, 50Hz 220-240V~50Hz, 1Ph 220-240V~50Hz, 1Ph 1Ph, 220-240V~,
50Hz
1Ph, 220-240V~,
50Hz
3Ph, 380-420V~,
50Hz
Cooling Capacity Btu/h 9000 12000 18000 24000 30000 36000
Input W 820 1345 2020 2920 3650 3625
Rated current A 3.7 6.3 9,3 13.1 16.4 7.3
EER W/W 3.21 2,61 2.61 2.41 2.41 2.91
Heating Capacity Btu/h 9500 12000 18000 24000 30000 36000
Input W 770 1170 1725 2335 2920 3350
Rated current A 3.4 5.8 8,0 10.6 13.2 6.8
COP W/W 3.61 3,01 3.06 3,01 3,01 3.11
Moisture Removal L/h 1.0 1,1 1.6 2,1 2.6 3.6
Max. input
consumption
W 1100 1800 2500 3200 3850 4300
Max. current A 5.5 8.0 12.0 16 20 7.5
Starting current A 21.7 22,2 25.9 36,8 36,8 53
Compressor Model PA103M1C-4DZDE2 PA130G1C-4DZ PA185M2C-4FT2 PA215X2CS-4KU1 PA240X2CS-4KU1 NN37YCAMT
Type ROTARY ROTARY ROTARY ROTARY ROTARY ROTARY
Brand GMCC GMCC GMCC GMCC GMCC MITSUBISHI
Indoor fan motor Model RPG13H RPG13H RPG25 YDK36-4C(A) YDK36-4C(A) YDK50-4E
Brand Welling Welling Welling Welling Welling Welling
Input W 34 34 55 67/58/50 67/58/50 76/67/54
Capacitor uF 1.2 - - 1.5 3 3 3
Speed (Hi/Mi/Lo) r/min 1220 / 1000 / 850 1250/1080/1000 1220 / 1100 / 850 1210/1120/1020 1210/1120/1020 1260/1170/1000
Indoor coil Number of rows 2 2 2 2 2 2
Tube pitch(a)xrow
pitch(b)
mm 20x11.28 21x13.37 21x13.37 21x13.37 21x13.37 21x13.37
Fin spacing mm 1.3 1,3 1.3 1,3 1.4 1,3
Fin type (code) Hydrophilic aluminium Hydrophilic
aluminium
Tube outer dia. & type mm ø6,innergroove tube ø7,innergroove tube
Coil LxHxW mm 540x240x22.56 538x252x26.74 769x273x26.74 799x336x26.74 2397x357x26.72 965x420x26.74
Number of circuits 2 2 3 4 4 6
Indoor air flow (Hi/Mi/Lo) m3/h 480/370/300 480/410/380 720/650/500 1000/930/840 1100/1020/930 1300/1200/1050
Indoor noise level (Hi/Mi/Lo) dB(A) 38/33/29 39/35/33 46/43/37 46/43/40 49/46/43 50/47/44
Indoor unit Dimension (WxDxH) mm 710x189x250 710x189x250 930x198x275 1036x230x315 1036x230x315 1250x230x325
Packing (WxDxH) mm 775x260x324 775x260x324 1015x265x350 1135x435x315 1135x435x315 1345x430x335
Net/Gross weight Kg 7 / 9.5 7 / 8.5 11.5 / 14.5 13/18 13.5/18 18/23
Features
Standard
Auto Restart Function
Cold Catalyst Filter
LED Display
Sleep Mode
Turbo Mode
Temp Compensation
Optional
Ionizer
Heating Belt (Outdoor)
Low Ambient Cooling
Gold Fin
Vitamin C Filter
Silver Ion Filter
Bio Filter
18
ASR-09HRN1 ASR-12HRN1 ASR-18HRN1 ASR-24HRN1 ASR-30HRN1 ASG-36HRN1
Outdoor fan motor Model YDK24-6T(B) YDK24-6(B) YDK36-6 YDK48-6H(A) YDK75-6D(B) YDK75-6C
Brand Welling Welling Welling Welling Welling Welling
Input W 70 77,3 70 110 170 162
Capacitor uF 3.0 2,5 2.5 3 5.0 5
Speed r/min 815 860 900 890 875 860
Outdoor coil Number of rows 1 1 1.6 2 2 2
Tube pitch(a)x row
pitch(b)
mm 21x13.37 21x13.37 21x13.37 21x13.37 21x13.37 25.4x22
Fin spacing mm 1.4 1,4 1.5 1.4 1.4 1.7
Fin type (code) Hydrophilic aluminium
Tube outside dia.& type mm ø7, innergroove tube
ø9.52, innergroove tube
Coil (LxHxW) mm 694*504*13.37 598x504x13.37 769+474x504x13.37 658x546x26.74 760x546x26.74 761x813x44
Number of circuits 1 2 4 4 4 4
Outdoor air flow m3/h 1650 1900 2000 2300 2500 3500
Outdoor noise level dB(A) 54 55 59 57 62 62
Outdoor unit Dimension (WxDxH) mm 700x240x540 700x240x540 780x250x540 760x285x590 820x330x595 900x315x860
Packing (WxDxH) mm 815x325x580 815x325x580 910x335x585 887x355x645 940x415x645 1043x395x915
Net/Gross weight Kg 24.5 / 26.5 24.5 / 26.5 32.5 / 34.5 43.5/47 44/48 72/76
Refrigerant type g R410A/620g R410A/630g R410A/1150g R410A/1400g R410A/1600g R410A/2450g
Design pressure MPa 4.2/1.5 4.2/1.5 4.2/1.5 4.2/1.5 4.2/1.5 4.2/1.5
Refrigerant piping Liquid side/
Gas side
mm(inch) ø6.35/
ø9.52(1/4"/3/8")
ø6.35/
ø12.7(1/4"/1/2")
ø6.35/
ø12.7(1/4"/1/2")
ø9.52/
ø15.9(3/8"/5/8")
ø9.52/
ø15.9(3/8"/5/8")
ø9.52/
ø15.9(3/8"/5/8")
Max. refrigerant pipe(L) m 20 20 20 25 25 25
Max. difference in level m 8 8 8 10 10 10
Connection wiring 1.5 (Optional) 1.5 (Optional ) 1.5 (Optional) 2.5 (Optional) 2.5(Optional) -----
Plug type 1.0x3 / VDE 1.5x3 / VDE 1.5x3 2.5x3/--- 2.5x3/--- -----
Thermostat type Remote Control Remote Control Remote Control Remote control Remote control Remote control
Operation temp Indoor(cooling/heating) ºC 17~32/0~30 17~32/0~30 17~32/0~30 17~32/0~30 17~32/0~30 17~32/0~30
Outdoor(cooling/heating) ºC 18~43/-7~24 18~43/-7~24 18~43/-7~24 18~43/-7~24 18~43/-7~24 18~43/-7~24
Application area m2 13-22 18-29 23-39 31-51 35-58 47-78
Qty’per
20’/40’/40'HQ
136/280/314 136/280/314 103/221/250 75/156/191 69/149/165 42/92/105
Note: 1. The above design and specifications are subject to change without prior notice for product improvemnet.
2. The noise level data reflects the level in an anechoic chamber.
R Series
19
Universal Outdoor Units
Specifications – Single (ON/OFF)
Outdoor Unit AOU-12HN1 AOU-18HN1 AOU-24HN1 AOU-36HN1 AOU-48HN1 AOUA-60HN1
Power supply V-ph-Hz 220~240-1-50 220~240-1-50 220~240-1-50 220~240-1-50 380~420-3-50 380~420-3-50
Max. input consumption W 1740 2950 3450 4950 6500 7500
Max. input current A 8,5 15 18 30 11 12,6
Compressor Model PA140G1C-4FT1 PA225M2CS-4KU2 PA290G2CS-4MU1 C-SBN301H5D C-SBN373H8D C-SBN453H8D
Type Rotary Rotary Rotary Scroll Scroll Scroll
Brand GMCC GMCC GMCC Sanyo Sanyo Sanyo
Outdoor fan motor Model YDK24-6F(B) YDK48-6H(A) YDK100-6D YDK190-6D(B) YDK190-6D(B) YDK65-6F(B)
Qty 1 1 1 1 1 2
Input W 63 110 167 290 290 162
Capacitor μF 2.5UF/450V 3uF/450V 5UF/450V 10uF/450V 10uF/450V (3.5UF/450V)X2
Speed r/min 800 890 900 830 830 765
Outdoor coil Number of rows 1 2 2 1,5 2 2
Tube pitch(a) x row pitch(b) mm 22×19.05 21x13.37 21x13.37 21x13.37 22x19.05 22x19.05
Fin spacing mm 1,4 1,4 1,4 1,4 1,6 1,6
Fin type Hydrophilic aluminum
Tube outside dia. & type mm ø7.94,inner grooved tube
Coil (LxWxH) mm 737×506×19.05 660x546x26.74 785x651x26.74 890x903x26.74 887x880x38.1 837x1100x38.1
Number of circuits 2 4 4 6 10 4
Outdoor air flow (Max.) m3/h 1800 2400 2700 5500 6000 6500
Outdoor noise level (sound pressure) dB(A) 55 58 59 61 63 63
Throttle type Capillary Capillary Capillary Capillary Capillary Capillary
Outdoor unit Dimension (WxDxH) mm 780x250x547 762x282x593 842x324x695 990x354x966 990x354x966 900x340x1167
Packing (WxDxH) mm 910x335x575 887x355x645 965x395x755 1120x435x1100 1120x435x1100 1032x443x1307
Net/Gross weight kg 28/30 37/39 48/54.5 86/98 90/95 96/105.5
Refrigerant type/Qty Type R410A R410A R410A R410A R410A R410A
Charged volume kg 0,96 1,4 1,8 2.6 2,8 3.2
Design pressure MPa 4.2/1.5 4.2/1.5 4.2/1.5 4.2/1.5 4.2/1.5 4.2/1.5
Refrigerant piping Liquid side/ Gas side mm (inch) ø6.35/ø12.7(1/4"/1/2") ø9.52/ø15.9(3/8"/5/8") ø9.52/ø19(3/8"/3/4")
Max. pipe length m 15 25 25 30 50 50
Max. difference in level m 8 15 15 20 25 25
Ambient temperature Cooling ºC 18~43 18~43 18~43 18~43 18~43 18~43
Heating ºC -7~24 -7~24 -7~24 -7~24 -7~24 -7Φ24
Note: 1. The above design and specifications are subject to change without prior notice for product improvemnet.
2. The noise level data reflects the level in an anechoic chamber.
12k Btu/h 24k Btu/h18k Btu/h 36k Btu/h 48k, 60k Btu/h
20
Airco was founded in 1949 and - since then - we have been striving continually to develop environmentally friendly, energy efficient and cost effective comfort and process cooling solutions for our customers.
We endeavor to supply the correct product for the application maintaining the highest possible quality standards. Our dedicated team of people are ready to serve and assist.
0861 COOLING www.airco.co.za
Address: 39 Webber Street, Selby Postal: PO Box 61441 Marshalltown 2107
Tel: 011 493 0169 Fax: 011 493 7660
Head Office (Johannesburg)