FRP-Reinforced Glulam Bridges: Development and Implementation

Prof. Bill Davids, Prof. Habib Dagher, Dr. Robert Lindyberg, Prof. Roberto Lopez-Anido

Page 2: FRP-Reinforced Glulam Bridges: Development and Implementation · FRP-Reinforced Glulam Bridges: Development and Implementation ... small amount of FRP that are stronger than beams

FRP-Reinforced Glulam

• Low grades stronger in compression• Reinforced concrete analogy – by using FRP as

tension reinforcement, we mitigate tension failure

Tension

Compression

Can we build beams with low-quality, cheap laminations and a small amount of FRP that are stronger than beams with high-

grade tension laminations?

Page 3: FRP-Reinforced Glulam Bridges: Development and Implementation · FRP-Reinforced Glulam Bridges: Development and Implementation ... small amount of FRP that are stronger than beams

FRP-Reinforced Glulam BeamsStrength model and beam strength testing

(H. Dagher and R. Lindyberg)

Wood-FRP bond integrity(H. Dagher, R. Lopez-Anido, B. Goodell, D. Gardner, Y. Hong, B. Herzog, L. Muszyński, C. Tascioglu)

Bridge girder fatigue behavior(W. Davids, M. Richie)

Demonstration structures(H. Dagher, W. Davids, R. Lindyberg, R.Lopez-Anido)

AASHTO design specifications

Page 4: FRP-Reinforced Glulam Bridges: Development and Implementation · FRP-Reinforced Glulam Bridges: Development and Implementation ... small amount of FRP that are stronger than beams

FRP-Glulam Strength and Ductility

130mm x 305mm x 6.4m span

0

100kN

0 250mm

CONTROL:MOR=27.7MPa

1% GRP:MOR=49.9MPa

3% GRP:MOR=65.3MPa

Mid-Span Displacement

Load

Page 5: FRP-Reinforced Glulam Bridges: Development and Implementation · FRP-Reinforced Glulam Bridges: Development and Implementation ... small amount of FRP that are stronger than beams

FRPUTS, E (mean, COV, PDF)

Lamstock- UTS, UCS, E

(mean, COV, PDF)- 3x3 correlation matrix

strain

stre

ss

Bending Strength Prediction

Page 6: FRP-Reinforced Glulam Bridges: Development and Implementation · FRP-Reinforced Glulam Bridges: Development and Implementation ... small amount of FRP that are stronger than beams

Moment-Curvature Analysis

N.A.

εc

ε(y) σ(y)

fyield

C

T

Φ

∑ ∫∑ ∫

=

=⇒=

ydAM

dAF

σ

σ 00 Gives NA location

Gives M corresponding to Φ

Page 7: FRP-Reinforced Glulam Bridges: Development and Implementation · FRP-Reinforced Glulam Bridges: Development and Implementation ... small amount of FRP that are stronger than beams

• M-Φ simulations repeated many times for different randomly generated cross-sections

• Result is the CDF of beam MOR and MOE• Allowable Bending Stress Fb= 5%LTL MOR/2.1

0.00

0.20

0.40

0.60

0.80

1.00

34 62MOR (MPa)

Cum

ulat

ive

Dis

trib

utio

n

5% LTL MOR

Monte Carlo Simulation

Page 8: FRP-Reinforced Glulam Bridges: Development and Implementation · FRP-Reinforced Glulam Bridges: Development and Implementation ... small amount of FRP that are stronger than beams

Beam 37-B-3

MOR = 46.9 MPa

FRP-Glulam Testing(11m span – 1.2% GFRP)

Page 9: FRP-Reinforced Glulam Bridges: Development and Implementation · FRP-Reinforced Glulam Bridges: Development and Implementation ... small amount of FRP that are stronger than beams

Validation of Analyses 279 Beam Tests

Test Series Sample size Difference5th Fb

6.4m 90 1 %11.0m 66 4 %15.2m

2.9m- 19.5m4875

7 %5 %

5th

0.00

0.20

0.40

0.60

0.80

1.00

5000 6000 7000 8000 9000

b

Page 10: FRP-Reinforced Glulam Bridges: Development and Implementation · FRP-Reinforced Glulam Bridges: Development and Implementation ... small amount of FRP that are stronger than beams

0

0.2

0.4

0.6

0.8

1

1.2

V = b x d x l

Cv

CV = (1291.5/V) 0.1

2%

130mm x 305mm x 6.4m span

273mm x 1370mm x 30.5m

0%

1%

Volume Effect

Page 11: FRP-Reinforced Glulam Bridges: Development and Implementation · FRP-Reinforced Glulam Bridges: Development and Implementation ... small amount of FRP that are stronger than beams

wood expands and contracts

FRP

Wood-FRP Bond IntegrityHygrothermal Effects are #1 Durability Issue

Wood-FRP InterfaceStresses

Stressconcentration

Page 12: FRP-Reinforced Glulam Bridges: Development and Implementation · FRP-Reinforced Glulam Bridges: Development and Implementation ... small amount of FRP that are stronger than beams

Screening Study: Nine FRP/Adhesive Systems ASTM D2559: 4 of 9 Passed: 4 of 9 Passed

E-glass vinyl ester

Resin infusion

Fabric reinforcement bound and bonded by SCRIMP

E-glass urethane pultrusionPre-consolidated sheet bonded w/ urethane

E-glass epoxycontinuous lamination

Pre-consolidated sheet bonded w/ epoxy

Carbon vinyl ester

Resin infusion

Fabric reinforcement bound and bonded by SCRIMP

Material Fiber type

Polymer matrix

FRP fabrication

Bonding process

A

B

C

D

Page 13: FRP-Reinforced Glulam Bridges: Development and Implementation · FRP-Reinforced Glulam Bridges: Development and Implementation ... small amount of FRP that are stronger than beams

Fatigue Testing

• Eighteen 6.1m-span specimens loaded in 4-point bending

• Fatigued for 2 million cycles at 2Hz

• Loading to 81% of Fv concurrently with 1.5Fb

• Stress ratio fixed at 0.33

• Daily static load tests

• Loaded to failure post-fatigue to quantify residual strength

Page 14: FRP-Reinforced Glulam Bridges: Development and Implementation · FRP-Reinforced Glulam Bridges: Development and Implementation ... small amount of FRP that are stronger than beams

Compression failure(post-fatigue)

• 14 of 18 specimens failed in tension• Two shear failures, two compression failures

Shear failure(post-fatigue)

Fatigue Testing Results

Page 15: FRP-Reinforced Glulam Bridges: Development and Implementation · FRP-Reinforced Glulam Bridges: Development and Implementation ... small amount of FRP that are stronger than beams

• Glulams with full-length reinforcing are not prone to fatigue failures– Potential for compression and shear failures at

higher reinforcement ratios– Significant delaminations between wood and

FRP can be tolerated in high shear regions

Fatigue Testing Results

Page 16: FRP-Reinforced Glulam Bridges: Development and Implementation · FRP-Reinforced Glulam Bridges: Development and Implementation ... small amount of FRP that are stronger than beams

Fairfield Bridge70’ span FRP-glulam with composite concrete deck

Page 17: FRP-Reinforced Glulam Bridges: Development and Implementation · FRP-Reinforced Glulam Bridges: Development and Implementation ... small amount of FRP that are stronger than beams

Milbridge PierMultiple-span FRP-reinforced glulam deck panels

Page 18: FRP-Reinforced Glulam Bridges: Development and Implementation · FRP-Reinforced Glulam Bridges: Development and Implementation ... small amount of FRP that are stronger than beams

Specification DevelopmentASTM D7199-07: Standard Practice for Establishing Characteristic Values for Reinforced Glued Laminated Timber (Glulam) Beams Using Mechanics-Based Models

• Passed in 2007

• Contains provisions for establishing FRP-glulam strength

• Methods based on moment-curvature analysis and Monte-Carlo simulation described earlier in presentation

• References ASTM D2559 for assessment of wood-FRP bond durability

Page 19: FRP-Reinforced Glulam Bridges: Development and Implementation · FRP-Reinforced Glulam Bridges: Development and Implementation ... small amount of FRP that are stronger than beams

Specification DevelopmentAASHTO LRFD Bridge Design Specifications

• Section 8, various articles• 8.4.1.3 Tension-Reinforced Glulams defined

– Type and amount of reinforcement– Design values determined via ASTM D7199

• Modification to adjustment factors– 8.4.4.5 Volume factor – no reduction in Fb

– 8.4.4.3 Wet service factor– 8.4.4.2 Format conversion factor (ASD – LRFD)

Page 20: FRP-Reinforced Glulam Bridges: Development and Implementation · FRP-Reinforced Glulam Bridges: Development and Implementation ... small amount of FRP that are stronger than beams

Specification DevelopmentAASHTO LRFD Bridge Design Specifications

Philosophy:

• Design engineer specs a value for Fb and beam dimensions

• Laminator designs layup using ASTM D7199 provisions

• Lamstock species, grade, and layup may be varied

• FRP reinforcement type and percentage refined

Page 21: FRP-Reinforced Glulam Bridges: Development and Implementation · FRP-Reinforced Glulam Bridges: Development and Implementation ... small amount of FRP that are stronger than beams

Sample AASHTO Design Calcs• Douglas fir L1-L2 layup (low grade laminations)

• Size beam for 56’ span bridge girders spaced at 4’-6”

• Reinforcing scenarios: 0%, 1%, 2% and 3% FRP

FRP Percentage

Fb(psi)

E(msi)

Beam depth(in)

Beam Width(in)

0% 1500 1.44 66 6.751% 2600 1.57 53 6.752% 3400 1.68 46 6.753% 3800 1.78 45 6.75

Page 22: FRP-Reinforced Glulam Bridges: Development and Implementation · FRP-Reinforced Glulam Bridges: Development and Implementation ... small amount of FRP that are stronger than beams

Conclusions

• Over a decade of research is bearing fruit

• Specifications capture results of research findings

• Ongoing collaboration between industry, the APA and UMaine to deliver FRP-glulam to market

• Economics of FRP-glulam are being studied

Page 23: FRP-Reinforced Glulam Bridges: Development and Implementation · FRP-Reinforced Glulam Bridges: Development and Implementation ... small amount of FRP that are stronger than beams

Acknowledgments

• The FHWA (program manager S. Duwadi)• The National Science Foundation• The USDA• The MaineDOT• APA - The Engineered Wood Association