OPTIFLUX
... exceeds your expectations
3 x 100% diagnostics
One for all applications
Custody transfer is standard
Sets new standards in electromagnetic flowmetering
With conductivity measurement
Electromagneticflowmeters
KROHNE 04/2004 7.02478.21.00
CH
Go for the OPTImumOPTIFLUX exceeds
3 x 100% diagnosticsOPTIFLUX overcomes the drawbacks of some SIL2-certified equipment:
detects errors unrecognised under SIL2
indicates erroneous results in the application(e.g. because of gas bubbles), which SIL2 cannot do
show up errors in accuracy and linearity, again unseen by SIL2
The 3 x 100% diagnostics in OPTIFLUX is, therefore,much better for you than a normal SIL2 certifiedmeter.
One for all applicationsWith just one signal converter and the widest rangeof flow sensors, the new OPTIFLUX cover all applica-tions, from a simple water measurement to corrosiveor abrasive products or even pulp in the paperindustry. Simplified engineering, procurement andinventory lead to cost-savings for the user.
This new concept marks a new era, and is the resultof more than 40 years experience in electromagneticflowmetering.
Sets new standards in electromagnetic flowmeteringUsing brand new technology has enabled us toincrease the measuring performance of OPTIFLUXeven further. These improvements are particularlyuseful where todays meters begin to capitulate.Examples of this include very low conductivity,measurement of rapid product changes with corres-ponding changes in pH or the measurement of pulpin the paper industry.
This increase in performance was possible by a 30-fold improvement in the measuring techno-logy components. Here we exploited all known optimization potentials.
with KROHNE your expectations
The new unique inbuilt diagnosticsThe new inbuilt diagnostics not only fulfil theNAMUR guidelines, they exceed them by far. Thenew converter can check and detect whether it isstill within its specifications or has been correctlyinstalled.The 3 x 100% diagnostics consist of:
100% ApplicationsDiagnosticsA working group led by NAMUR - consisting ofrepresentatives and users - analysed all measuringtechnologies. They defined for each one the applica-tion problems that an optimum meter would beable to detect.The list highlighted here on the right shows thoseapplication problems, as well as some additionalones integrated into OPTIFLUX.The indications given by OPTIFLUX together with apossible exclusion diagnosis by the user will cer-tainly help you to conclude what the problem is inthe application.
100% Out-of-specDiagnosticsThe OPTIFLUX checks periodically whether it is stillworking to within its specifications.The following is checked:
the accuracy by feeding in a test signal
the linearity of the meter
the accuracy of the field current used to generate the magnetic field
The test results can be viewed at any time usingHART and KROHNEs new PACTware tool, and aVerification Certificate can be printed out. There isno longer any need for time-consuming verificationmeasurements.
100% Meter DiagnosticsDiagnostics normally refers to the meters diagnostics, which in the case of OPTIFLUXcovers all these items:
Microprocessor test
Software test
Memory test
Electronics temperature test
Output tests for interruption, and the correct load
The OPTIFLUX vitality check
Fulfils and even exceeds theVDI / VDE / NAMUR - Guideline 2650
Accuracy check
Gas bubbles
Electrode corrosion
Conductivity too low
Liner damage
Electrode fouling
External magnetic fields
Short-circuited electrodes
Partial filling
Change in flow profile
Change in conductivity
The new operatingconcept nothingcould be easierThe large blue-white fully graphic display With more information.
Operation using touch-screen keys Without opening the cover.
QuickStart menu For easy commissioning, and user-configurable.Here you input all parameters you need.
Online helpInput ranges and limits, parameter values as delivered and an explanation of the parameter.For each parameter the best help you can get.
OPTIFLUX sets new new standards inflow measurementCustody transfer is standard
The standard instrument itself fulfils the highdemands on accuracy and reproducibility. Togetherwith its comprehensive diagnostics this makes it predestined for custody transfer applications.
Highest accuracy - Now as good as 0.15% of the measured value
The optimized measuring technology behind OPTIFLUX and the new highly effective screening in the sensor lead to an
accuracy of 0,15% and a
reproducibility of 0,06%
These improvements make OPTIFLUX enormouslyreliable in the presence of
high bubble content
high solids content
turbulent flow
New conductivity measurement
The new conductivity measurement in OPTIFLUXopens up brand new applications, such as:
detection of product change or
quality management of cleaning processes
In many cases a separate conductivity meter is nolonger needed.
Go for the OPTImumOPTIFLUX exceeds
Approvals Everything you need
OPTIFLUX offers a wealth of approvals:
from custody transfer to OIML and KIWA
from Ex such as ATEX, FM, CSA, SAA and more
for hygienic applications with 3A, EHEDG, FDA
So you can use OPTIFLUX worldwide for all applications.
with KROHNE your expectations
OPTIFLUX One forall applicationsThe new converter is a multi-talent
In a recent BASF expertise they wrote, The construc-tion of the new converter electronics of the IFC 300deserves particular praise. For the first time a con-verter has been successfully built that can not onlybe used in all applications but it also comes invarious housings from compact to field remote towall-mounted. Compatibility to already installed,older meters is built-in.
Standard or costly extra?
Designed to satisfy, also means we build all the functionalities into the standard instrument at noextra cost. Whether its the new large-size completelygraphical display, the 3 x 100% diagnostics or thecustody transfer. Its all standard.
Your I/O combination is also available
The vast array of I/O combinations is bound to fulfilyour needs whether you need a current output,active or passive, Ex i or non-Ex, pulse output orstatus input or output, HART, PA, DP, FF and allI/O are galvanically separated.
OPTIFLUX has it all.
Optimized installation and service concept
As soon as you wire up the meter, you notice thedifference. Everything goes that much quicker andeasier. Even if the electronics really do need to bereplaced, simple swap the entire cassette withoutfiddling about with EPROMs or PCBs, and start themeter with all the current settings retained.
... with all thesefeatures:
For high reliability and lowest conductivity
OPTIFLUX 7300 C, electrode-free, with capacitive signal pick up for products down to 0.05 S/cm.
Secondary Containment
OPTIFLUX 4000 up to 40 bar.
For process temperatures up to 180C even for Ex
All liners available from hardrubber to PFAto ceramic
From DN 2.5 to 3000
Always the right meter ...
... the widest range means you always get the best meter.
OPTI
FLUX
100
0OP
TIFL
UX 2
000
OPTI
FLUX
400
0OP
TIFL
UX 5
000
OPTI
FLUX
600
0OP
TIFL
UX 4
040
COP
TIFL
UX 7
300
CTI
DALF
LUX
4110
PF
BATC
HFLU
X 50
15 C
Water & wastewater
Water distribution
(Waste)water treatment
Sludge sewage
Partially filled pipelines
Chemical
Dosing of additives
Corrosive, abrasive liquids /Slurries
Hazardous areas
Paper & Pulp
Pulp
Liquor
Additives, bleeches, colourants
Hygienic / Sanitary
Food & Beverages, Pharmaceutical
Blending, dosing, batching
Volumetric filling machine
Other
HVAC
Machinery
Dredging, Metals & Mining, Ore
Master / transfer meters
United KingdomKROHNE Ltd.Rutherford DrivePark Farm Industrial EstateWellingborough,Northants NN8 6AE, UKTEL.: +44(0)19 33-408 500FAX: +44(0)19 33-408 501e-mail: [email protected]
AustraliaKROHNE Australia Pty LtdQuantum Business Park10/287 Victoria RdRydalmere NSW 2116TEL.: +61 2 8846 1700FAX: +61 2 8846 1755e-mail: [email protected]
South AfricaKROHNE Pty. Ltd.163 New RoadHalfway House Ext. 13MidrandTEL.: +27(0)11-315-2685FAX: +27(0)11-805-0531e-mail: [email protected]
Other countriesKROHNE MesstechnikGmbH & Co. KGLudwig-Krohne-Str.D-47058 DuisburgTEL.: +49(0)203-301-0FAX: +49(0)203-301-389e-mail: [email protected]
www.krohne.com
KROHNE exceeds your expectations
OPTIFLUX 2000 OPTIFLUX 5000OPTIFLUX 4000
IFC 300 IFC 010
OPTIFLUX 6000OPTIFLUX 1000
The water & wastewater meter Accurate and hard-wearingThe standard process meter The sterile meterThe economical meter
No electrodes For filling machinesFor partially filled pipesTwo-wire EMF
OPTIFLUX 4040 C TIDALFLUX 4110 PFOPTIFLUX 7300 C BATCHFLUX 5015 C
OPTIFLUX One for all applications
OPTIFLUX converters
OPTIFLUX sensors
OPTIFLUX for special-purposes
KROHNE is one of the very few manufacturers who can offer a comprehensive rangeof level and flow products ensuring that the right solution is available for eachapplication. The KROHNE range includes the following products and technologies:
For further information, please contact your local KROHNE office or visit ourinternet site, www.krohne.com
Flowmeters: Electromagnetic, Ultrasonic,
Variable Area and Vortex
Mass Meters: Coriolis
Flow Controllers
Level Gauges, Radar (contact-free and guided
radar)
Level Switches: Float, Capacitance and Vibrating
Probe
Density/concentration: Coriolis
Communications: HART, PROFIBUS, FOUNDATION
FIELDBUS, MODBUS, AMS, PDM, DeltaV,
DTM / FDT 1.2 Systems, e.g. PACTware.