B
CD
E
F
H
I
J
K
L
M
P
35 m²Electrical Plant Room
36 m²Boiler Room
32 m²Solar Plant Room
45 m²Water Plant Room
24 m²Hall
5 m²Service Riser
114FD30
115FD30
125FD30
138139FD30
140FD30
141FD60
142FD30
CarPark Exit
CarPark Entrance
28 m²Stair 4
18 m²Building Contol Centre
7 m²Bed Lift
5 m²Lift
37 m²Lobby
FD 31FD30
37.5m (TD)
26.1m (TD
)
69.000°
9.9m (OD)
12
3
45
67
89
10
11
12
14
15
16
17
18
19
20
21
22
23
24
13
A
B
CD
EF
H
I
J
K
L
M
P
5300
6FD30
8FD30
9FD30
10FD3011
FD3012FD3013
FD3014FD30
15FD30
17FD30
18FD30
34FD30
36FD30
37FD30
38FD30
39FD30
42FD30
43FD30
44FD30
45FD30
46FD30
47FD30
48FD30
49FD30
50FD30
109FD30
110FD30
111FD30
16 m²Book TR Room
24 m²Speech Therapy
20 m²Stair 3
27 m²Speech Therapy
14 m²Book TR Room 16 m²
Medical Store
4 m²WC & Shower
4 m²Staff WC
6 m²Hall
9 m²Womens Toilets
4 m²Womens WC
8 m²Mens Toilets
5 m²Mens WC
18 m²Wound Clinic
11 m²Medical Store 18 m²
Wound Clinic
15 m²Bookable Room
28 m²Family Rm/Care Doc
34 m²Reception
30 m²Waiting Area
20 m²Community Welfare
15 m²Bookable Room
18 m²Room
17 m²Child Health
17 m²Sound Proof Room
14 m²Stairs
32 m²HSE Circulation
359 m²Pharmacy
120 m²Medical Services Rm1
116 m²Medical Services/Storage
19 m²HSE Store
11 m²HSE Hall
34 m²HSE Dr Room
51 m²HSE Reception & Treatment Rm
16 m²HSE Office
127FD60
128FD60 69
FD60 81 FD30
80 FD30
79FD30
78FD30
129
FD30
15 m²Stairs 1
29 m²Stair 4
112 m²Restaurant /Caffe
80 m²Medical Services 67 m²
OT GA Room
72FD60
77 FD30
71 FD30
76FD30
70 FD30
73FD60
74FD60
75 FD60
82 FD60
9 m²WC F
5 m²Hall
9 m²WC M 14 m²
Storage 7 m²Hall
4 m²WC
107 106FD60
108
136FD60
135
FD60
133
FD60
91 m²Room
4664
2703
5190
14.2m (O
D)
27.1m (TD)9.3m (TD)
15.6m (TD)
18.4m (TD)
6.9m
(OD)
5.6m (TD
)
www.autodesk.com/revit
Scale
LECTURER
Drawn by
Date
Project number
Institute of Technology CarlowBSc. in Architectural Technology
Year 3 2015-2016
1 : 200
19/0
4/20
16 1
8:16
:59
Fire Certificate Plans
Project Number 3
Carlow Primary Health Care Centre
22/04/2016
Xhevdet Haliti
Dan O Sullivan, Noel Dunne,Mark Duffy
A129
1 : 200Fire Basement floor plan1
1 : 200Fire Ground floor plan2
LEGEND:Travel Distances:
- One Direction: OD- Two Direction: TD
30 min protected corridor in accordancewith section 1.2.5.1.and table A1 TGD B 2006
60 min protected stair wall in accordancewith table A2 TGD,Part B 2006. i.e. topstorey served not more than 5m aboveGround level
90 min protected stair well in accordancewith table A2 TGD, Part B 2006. Top storeyserved not more than 20m above Ground Level
90 min compartment wall/floor in accordancewith section 3.2, table A2 and appendix C,TGD B 2006
30 min fire resistant door set in accordancewith BS476 Part 22, fitted with Intumescentstrips and smoke seals. Doorset to be fittedwith automatic self-closing device which shallbe capable of closing the for from any angleand against any latch fitted
Disabled refuge area (1400x900mm). Two waycommunication to the internal refuge area only
Emergency escape lighting to comply with table 1.8 TGD B-to be designed , installed and certified in accordance withIS 3217:20013.
Fire detection system type L1 to be designed, certified inaccordance with IS 3218:2009(2013)
The use, inspection and maintenance of fire extinguishersto be designed , installed and certified in accordance withIS 291:2002
Steel columns, beams and portal frames used to supportload bearing, fire resisting elements of structure to beprotected and to give 90min fire rating
60 min fire resistant door set in accordancewith BS476 Part 22, fitted with Intumescentstrips and smoke seals. Doorset to be fittedwith automatic self-closing device which shallbe capable of closing the for from any angleand against any latch fitted
NOTES:(1) Refers to area of room or storey, as appropriate, with area calculated in accordance with Section 1.0.10(a) of TGD-B 2006.(2) Occupancy load factors as per Table 1.1 of TGD-B 2006.(3) Such areas will generally be unoccupied or alternatively will be occupied by the same persons within the remainder of the
premises and therefore double counting of both areas are avoided.(4) Number of persons to such rooms taken as two (i.e. a patient and a consultant)