28
G-SPEED eS INSTALLATION GUIDE - Windows G-SPEED™ eS Windows Installation Guide G-Technology Inc. Tel: (310) 449-4599 Fax: (310) 449-4670 [email protected] P/N GSPEED eS v1.1PC TABLE OF CONTENTS 1. INTRODUCTION (Pg 4) 2. SAFETY PRECAUTIONS 3. SYSTEM REQUIREMENTS 4. WHAT’S IN THE BOX 5. G-SPEED eS OVERVIEW (Pg 5) 6. OPTIONAL G-TECH PCIe RAID CONTOLLER OVERVIEW 7. G-SPEED eS AUDIBLE ALARMS (Pg 6) 8. SETTING UP G-SPEED eS WITH THE G-TECH PCIe RAID CONTROLLER (Pg 6) 9. SETTING UP G-SPEED eS USING THE WEB GUI (Pg 12) 10. CONFIGURING TWO G-SPEED eS UNITS IN RAID 5 MODE (Pg 16) 11. WHAT TO DO IN THE EVENT OF A DISK DRIVE FAILURE (Pg 19) 12. TECHNICAL SUPPORT/LIMITED WARRANTY (Pg 20) APPENDIX A – DETAILED INFORMATION ON USING THE WEB GUI APPENDIX B – EXPLANATION OF RAID LEVELS APPENDIX C – NOTES APPENDIX D – FORMATTING G-SPEED USING DISK MANAGEMENT Page 1

G-SPEED™ eS Windows Installation Guide

  • Upload
    vuhuong

  • View
    228

  • Download
    1

Embed Size (px)

Citation preview

Page 1: G-SPEED™ eS Windows Installation Guide

G-SPEED eS INSTALLATION GUIDE - Windows

G-SPEED™ eS Windows

Installation Guide

G-Technology Inc.

Tel: (310) 449-4599 Fax: (310) 449-4670

[email protected]

P/N GSPEED eS v1.1PC

TABLE OF CONTENTS

1. INTRODUCTION (Pg 4)

2. SAFETY PRECAUTIONS

3. SYSTEM REQUIREMENTS

4. WHAT’S IN THE BOX

5. G-SPEED eS OVERVIEW (Pg 5)

6. OPTIONAL G-TECH PCIe RAID CONTOLLER OVERVIEW 7. G-SPEED eS AUDIBLE ALARMS (Pg 6)

8. SETTING UP G-SPEED eS WITH THE G-TECH PCIe RAID

CONTROLLER (Pg 6)

9. SETTING UP G-SPEED eS USING THE WEB GUI (Pg 12)

10. CONFIGURING TWO G-SPEED eS UNITS IN RAID 5 MODE (Pg 16)

11. WHAT TO DO IN THE EVENT OF A DISK DRIVE FAILURE (Pg 19)

12. TECHNICAL SUPPORT/LIMITED WARRANTY (Pg 20)

APPENDIX A – DETAILED INFORMATION ON USING THE WEB GUI APPENDIX B – EXPLANATION OF RAID LEVELS APPENDIX C – NOTES APPENDIX D – FORMATTING G-SPEED USING DISK MANAGEMENT

Page 1

Page 2: G-SPEED™ eS Windows Installation Guide

G-SPEED eS INSTALLATION GUIDE - Windows

Page 2

Page 3: G-SPEED™ eS Windows Installation Guide

G-SPEED eS INSTALLATION GUIDE - Windows

Page 3

Page 4: G-SPEED™ eS Windows Installation Guide

G-SPEED eS INSTALLATION GUIDE - Windows

1. INTRODUCTION Thank you for purchasing G-SPEED eS from G-Technology, Inc. (G-Tech)! Specifically designed for professional content creation applications, G-SPEED eS features a high-speed 3Gbit/sec eSATA interface and when used in conjunction with the optional G-Tech PCI Express (PCIe) RAID controller provides RAID 0, 1, 5, 10 and JBOD functionality with greater than 2TB support in Windows 32bit environments. Up to four G-SPEED eS units can be attached to the G-Tech RAID controller for storage capacities to 16 TB and data rates over 600 MB/sec. G-SPEED eS supports multi-stream video editing workflows.

2. SAFETY PRECAUTIONS The disk drives contained in your G-SPEED eS are delicate electronic instruments and are susceptible to damage due to excessive physical shock. Place the unit in a vented area away from moisture or liquids. Please handle the unit with care. Do not open the case. Doing so will void the warranty. If the Product is returned with damage caused by improper handling, the warranty will be void and liability will rest with the user.

3. SYSTEM REQUIREMENTS

• PCIe equipped workstation • Microsoft Windows 2000/XP/2003/Vista • G-Tech PCIe RAID Controller or third party port multiplier

aware eSATA host adapter

Optional G-Tech 4-port, PCIe x4 RAID Controller

4. WHAT’S IN THE BOX

Take a moment to ensure that the following items are included in the box. If anything is missing, please call G-Tech at (310) 449-4599. Please keep the shipping container and packing materials. In the unlikely event that you need to return G-SPEED eS to us for any reason, you must use the G-Tech shipping container. If the Product is returned damaged caused by improper packaging, the warranty will be void and liability will rest with the user.

• G-SPEED eS storage system • 4 removable SATA drive modules (installed in unit) • (2) disk module keys • 1-meter eSATA cable • AC Power cable • Optional – G-Tech PCIe RAID controller • Configuration Utility & Installation CD

Page 4

Page 5: G-SPEED™ eS Windows Installation Guide

G-SPEED eS INSTALLATION GUIDE - Windows

Page 5

5. G-SPEED eS OVERVIEW

6. OPTIONAL G-TECH PCIe RAID CONTOLLER OVERVIEW

The optional G-Tech PCIe RAID controller connects G-SPEED eS to your PCIe equipped workstation and provides RAID 0, 1, 5, 10 & JBOD functionality. You will choose your level of RAID protection when you set up the G-SPEED eS in Section 8. For an explanation of supported RAID levels, please refer to Appendix B.

G-SPEED eS is also compatible with third-party Windows port multiplier aware eSATA host adapters. Refer to your host adapter documentation to set up G-SPEED eS with these boards.

PCIe x4 interface RAID Engine

(4) High-speed 3 Gb/s eSATA ports. Supports up to (4) G-SPEED eS systems

(4) Removable Disk Drive Modules

Drive Module Power/Activity

LED

Temperature/Fan RPM Warning LED

Power Supply LED

Disk Module Lock Hole

ON/ OFF Switch

Remo

AC Input

vable Fan

3 GB/sec eSATA Port

Cable Lock Hole

Page 6: G-SPEED™ eS Windows Installation Guide

G-SPEED eS INSTALLATION GUIDE - Windows

Page 6

7. G-SPEED eS AUDIBLE ALARMS 7.1 The G-SPEED eS enclosure is equipped with an audible

alarm that sounds when:

1. The internal temperature of the G-SPEED eS enclosure reaches a temperature of 60° centigrade

and/or

2. When the main FAN fails or the RPM of the fan slows to a state where the fan can longer adequately cool the system.

In addition to the audible alarm, the Temperature/Fan Warning LED located on the front bezel of G-SPEED eS will illuminate.

If you hear an audible alarm and see the RED warning LED on the front of G-SPEED eS, stop using G-SPEED eS immediately. Check to see if the fan is spinning and move the unit to a cooler location. If the problem persists, contact G-Tech Support.

7.2 The G-Tech RAID controller is also equipped with an

audible alarm that sounds when:

1. A disk drive failure occurs

or

2. When the G-SPEED eS is removed from the RAID controller without first selecting “Unplug” in the Array Maintenance menu in the web GUI.

If you hear an audible alarm coming from the G-Tech RAID controller, see Section 11 “What to do in the Event of a Disk Drive Failure”. See Appendix B.1.7.2 for information on the proper way to hot “Unplug” G-SPEED eS.

8. SETTING UP G-SPEED eS WITH THE G-TECH PCIe RAID CONTROLLER Connecting G-SPEED to your workstation and configuring your system takes just a few steps as outlined below. For this example we will be installing G-SPEED eS on a Windows XP system. The installation is similar for Windows 2000, 2003 and Vista.

8.1 Installing the G-Tech PCIe RAID Controller

1. Install the G-Tech RAID controller into an available PCIe slot in your workstation.

2. Secure the RAID controller in place.

Page 7: G-SPEED™ eS Windows Installation Guide

G-SPEED eS INSTALLATION GUIDE - Windows

8.2 Attaching G-SPEED eS to the G-TECH RAID Controller 1. Attach one end of the supplied eSATA cable to the eSATA

port located on the back of G-SPEED eS.

2. Attach the other end of the eSATA cable to Port 1 (port closest to motherboard) on the G-Tech RAID controller as shown below.

3. Attach the power cord to the back of G-SPEED eS and connect the other end to AC power.

4. Power on G-SPEED eS.

8.3 Installing the G-Tech PCIe RAID Controller Software There are three steps required to fully install the software

for the G-SPEED eS Controller.

1. Install the Windows driver 2. Update the Controller firmware 3. Installing the web GUI

Check for software updates at http://www.g-technology.com/Support/

1. Install the G-SPEED eS Windows driver a. Power on the workstation b. Insert the G-Tech Product CD into the CD-ROM drive

When the CD loads a welcome screen may appear. Close this window.

c. When the system boots the “Found New Hardware Wizard” will appear. Select “Install from a list or specific location” and click <Next>.

Page 7

Page 8: G-SPEED™ eS Windows Installation Guide

G-SPEED eS INSTALLATION GUIDE - Windows

d. Select “Don’t Search, I will choose the driver to install” and click <Next>.

e. Click <Have Disk>.

f. Click on the <Browse> Button and navigate to the CD-ROM drive containing the G-Tech Product CD. Continue to “\Manuals-Drivers\G-SPEED eS\PC\GSeS Driver Win-v1.0\” Select the folder for your operating system and click <OK>.

g. Select “G-SPEED eS RAID Controller and click <Next>.

Page 8

Page 9: G-SPEED™ eS Windows Installation Guide

G-SPEED eS INSTALLATION GUIDE - Windows

h. When the Windows Logo warning screen appears click <Continue Anyway>.

i. The RAID controller driver will install and the Wizard will complete. Click <Finish>.

j. A new “Found New hardware Wizard” will open for the “G-Tech RCM device.” Click <Next>.

k. As before, click on “Don’t search. I will choose the driver to install.”

Page 9

Page 10: G-SPEED™ eS Windows Installation Guide

G-SPEED eS INSTALLATION GUIDE - Windows

l. Select “G-SPEED es RAID Controller” and click <Next>.

m. The RCM Device driver will install and the Wizard will complete. Click <Finish>. This completes the driver installation.

n. Remove the G-Tech Product CD. o. Restart your workstation.

2. Update the G-SPEED eS Controller firmware

a. Insert the G-Tech Product CD into the CD-ROM / DVD drive. When the disk loads a welcome screen should appear. Click on the <Manuals / Drivers> link.

NOTE: If the Menu screen does not appear, the “autorun” feature may not be enabled on your workstation. To load the menu manually go to the START menu and click on “Run.” Enter the drive letter of your CD-ROM containing the Product CD and then “autorun.exe.” For example “D:\autorun.exe”

b. This will open Windows Explorer. Navigate to the “G-SPEED eS\PC\GSeS Firmware-v2.2c” folder. Double-click “hptflash.exe” to launch the flash utility.

Page 10

Page 11: G-SPEED™ eS Windows Installation Guide

G-SPEED eS INSTALLATION GUIDE - Windows

c. Click <Open...>.

d. Select “rr231.xpm.22c” and click <Open>.

e. Click <Flash!> to begin the update process.

f. When the process is completed click <OK>.

g. Remove the G-Tech Product CD. h. Restart your workstation.

3. Installing the G-SPEED eS Web GUI.

a. Insert the G-Tech Product CD. When the disk loads a welcome screen should appear. Click on the <Manuals / Drivers> link.

Page 11

Page 12: G-SPEED™ eS Windows Installation Guide

G-SPE

b

c

d

EED eS INSTA

b. Navigate to t“Manuals-DrDouble click instructions,

. When the ins

. The Web GU

your G-SPEE

ALLATION G

the folder: ivers\G-SPEED on “Setup.exe” accepting the

stallation is com

I is ready to beED eS.

UIDE - Windo

eS\PC\GSeS W” and follow thedefaults.

mplete click <F

e launched and

ows

WEB GUI-vX.X” e onscreen

inish>.

configure

9. SET

TmaeG

wsd

9.

1

2

TTING UP G-SThe G-Tech RAImonitor the G-any web browequivalent. TG-SPEED eS on

NOTE: Wbuilt-in lim(2048GB).

with a new technolsize presented to thdisks of up to 16TB

1 Accessing th

1. Open your w

https:/

2. The followin<YES> butt

NOTE: save th

SPEED eS USINID controller wSPEED eS systwser such asThis section wn a Windows wo

indows 2000 / XPmitation that logic. The G-SPEED eSogy, Variable Sectohe operating syste

B.

he G-Tech PC

web browser an

//localhost:74

ng Security Aleton.

For easy access toe web address in y

NG THE WEB Gweb GUI is usedtem. The GUI s Safari, Interwill describe hoorkstation.

P are 32 bit opercal disks cannot S RAID Controller oor Size (VSS). VSm making it possib

Ie RAID Cont

nd enter the fol

402

ert window will

o the G-SPEED eS Wyour favorites

Page

GUI d to configure ais accessed usrnet Explorer ow to setup

rating systems witbe greater than overcomes this bar

SS increases the seble to now have log

roller Web GU

llowing address

appear. Click

Web GUI

e 12

and sing

or the

th a 2TB rrier

ector gical

UI

s:

the

Page 13: G-SPEED™ eS Windows Installation Guide

G-SPE

3.

EED eS INSTA

Enter “adminas the Passwo

Note: Sechanging

ALLATION G

n” as the User Nord and click on

ee appendix A.4. the password.

UIDE - Windo

Name and “000n the <Login>

5 for instructions

ows

00” (four zerosbutton.

s on

s) 4.

The main scrbelow. Each othe “Physical

Note: Tformattand reworksta

NOTE: features

reen of the weof the four drivDevice Informa

The G-SPEED eS ised for Mac OSX. Te-created to funation. Section 9.2

Please refer to APPs of the G-Tech RA

eb GUI will apves in the unit aation” section o

s shipped initializeThis configuration

nction correctly covers this process

PENDIX A for detailID Controller web

Page

pear as shownare displayed inof the GUI.

d as a RAID 0 arra needs to be deleteon your Windows.

led information on GUI.

e 13

n n

ay ed ws

the

Page 14: G-SPEED™ eS Windows Installation Guide

G-SPE

9.2 CTcofob

1.

2.

EED eS INSTA

Configuring thhe G-SPEED eSonfigured in RAor an explanatioelow to setup t

Launch the G-T

Click on the “Mbelow will appMaintenance W

ALLATION G

he RAID level S/G-Tech RAID AID 0, 1, 5, 10 on of RAID levethe system

Tech RAID Con

Maintenance” Liear. Click on <

Window.

UIDE - Windo

of G-SPEED econtroller comband JBOD. (Seels) Follow the

troller web GUI

ink and the win<Delete> in the

ows

eS bination can beee Appendix B directions

I.

ndow shown e Array

e 3

4

3. Click the <O

W

sto

4. The GUI wi

the <Createappear.

OK> button to p

WARNING: This wilored on G-SPEED e

ll refresh and e Array> butto

proceed.

l delete any data eS!

the array is non. The “Create

Page

ow deleted. Ce Array” page

e 14

lick will

Page 15: G-SPEED™ eS Windows Installation Guide

G-SPE

5.

EED eS INSTA

The Create Aarray and all ita RAID 0 arraselect it from Select RAID “Array Name”

NOTE: In thsystem can aselecting the

NOTE: When the initializaapproximate

ALLATION G

rray page is wts parameters. ay. (To set up the dropdown

0 for “Array T

his example we arealso be set up in Re appropriate settin

n creating redundaation process takesly 1hr 45m per TB

UIDE - Windo

where you con In this examp

p a different RAn menu labeled

Type”, enter G

creating a RAID 0RAID 1, 5, 10 or JBOng in the “Array Ty

nt arrays (RAID 1 s time. For RAID 5 of final capacity.

ows

nfigure the neple we will setuAID level simpd “Array Type.”

G-SPEEDeS fo

array. The OD mode by

ype” pull-down.

or RAID 5) it takes

w up ly ”)

or

6.

7.

8.

o(s

. Click the <Searray.

. To create an

enter the val

. If you are cre

choose the vindicated in t

NOTE: Wwith a buithan 2TB

overcomes this ba(VSS). VSS incresystem making it p

Arr

Up

2TB

4TB

8TB

elect All> to qu

array less thanue in MB in the

eating an arrayvalue for Variabthe table below

indows 2000 / XPlt-in limitation tha (2048GB). Therrier with a new t

eases the sector sossible to now hav

ray Capacity S

to 2TB

B -> 4TB

B -> 8TB

B -> 16TB

uickly select all

n the maximume Capacity field

y of Greater thale Sector Size a

w.

P are 32 bit opert logical disks can

e G-SPEED eS RAtechnology, Variabsize presented to ve logical disks of u

Sector Size

512

1k

2k

4k

Page

the disks for th

m available, .

an 2TB, as

rating systems not be greater AID Controller ble Sector Size

the operating up to 16TB.

e 15

he

Page 16: G-SPEED™ eS Windows Installation Guide

G-SPE

9.

10.

11.

12.

EED eS INSTA

Click <OK> on

. Click the <Crinitialize. A pbeen create

. The GUI will rcompleted init

NOTE: Wh the initiali

approxima . Your G-SPEEDwith your opdetailed instrformat the G-S

ALLATION G

n the warning m

reate> button popup will apped and is no

reload indicatinializing the RAI

hen creating redunzation process takeately 1hr 45m per T

D eS is now reaperating systemuctions on usSPEED eS for W

UIDE - Windo

message that a

and the arrapear confirmingw initializing.

ng that the G-SID 0 array.

ndant arrays (RAID es time. For RAID TB of final capacity

ady to be formm. See Appsing Disk Ma

Windows XP.

ows

ppears.

ay will begin tg the array ha

Click <OK>

SPEED eS has

1 or RAID 5) 5 it takes y.

matted for use pendix D for nagement to

to as >.

10. CFa

CONFIGURINGFollow the direarrays in RAID

1. Ensure thainstalled an

2. Attach bothcontroller ayour compu

3. Launch thetwo units awill display

G TWO G-SPEEections below 5 mode using t

t the G-Tech RAnd the driver an

h G-SPEED eS uas shown belowuter

e G-Tech RAID attached to the y information lik

ED eS UNITS Ito configure

the G-Tech RAI

AID controller ind web GUI are

units to the G-Tw, power the un

Controller we G-Tech RAID cke that shown b

Page

IN RAID 5 MOtwo G-SPEED D controller.

s properly e loaded.

Tech RAID nits and restart

b GUI. With controller, the Gbelow.

e 16

ODE

eS

the GUI

Page 17: G-SPEED™ eS Windows Installation Guide

G-SPE

4. CN

5. C

w

6. C

7. R“D

EED eS INSTA

Click on the “MName” GS Disk

Click the <Delewill appear.

WARNstored

Click the <OK>

Repeat the pr“Maintenance” Disk 1_1. The

ALLATION G

aintenance” link 1_0. The win

ete> button. Th

NING: This will dele on G-SPEED eS.

> button to dele

rocedure for Glink next to twindow below

UIDE - Windo

k next to the adow shown bel

he following wi

ete any data

ete the array.

GS Disk 1_1. he array with will appear.

ows

array with “OS ow will appear.

ndow

Click on th“OS Name” G

he GS

8.

9.

Click the <appear.

lick the

C

<arrays havethe <Creatwindow will

Delete> button

WARNING: This stored on G-SPEE

<OK> button e now been dete Array> but appear.

n and the follo

will delete any datD eS.

to delete the eleted as showtton. The “C

Page

owing window

a

array. Both n below. Click Create Array”

e 17

will

Page 18: G-SPEED™ eS Windows Installation Guide

G-SPEEED eS INSTA

10.

In this windowSelect RAID Enter G-SPEESelect Foregand Write BaClick <Select <Create> but

ALLATION G

w select the fol5 for “Array TyED-eS-R5 for “round for “Initack for “Cache All> button to tton to begin th

UIDE - Windo

lowing values ape:”, “Array Name:”, tialization Meth Policy:” select all diskshe initialization

ows

as shown:

od:”

s then click the process.

11

12

13

14

1. A popup wilcreated and

2. The GUI wilinitializing.

3. The RAID 545m per Tprocess is c5 and “Stat

4. Your G-SPEwith your oinstructions G-SPEED eS

l appear confirm is now initializ

l reload indicat

5 initialization pTB of final cacomplete, the Gus” as Normal

ED eS is now perating system on using DisS for Windows X

ming the array zing. Click <OK

ing that the G-

process takes apacity. Once

GUI will indicate.

ready to be fm. See Appensk ManagemenXP.

Page

has been K>.

SPEED eS is

approximately the initializate “Type” as RA

formatted for undix D for detaint to format

e 18

1hr tion AID

use iled the

Page 19: G-SPEED™ eS Windows Installation Guide

G-SPE

11. WHTheafaire

Fo

1

2

3

EED eS INSTA

HAT TO DO INhe G-Tech RAIDach of the disk dilpure, an audiblort the failed

NOTE: If G(RAID 1, 5However, tdrive shoul

ollow the steps

1. Launch the

2. Mute the alabutton.

3. The GUI wiAn exclamathat the “Sportion of G-SPEED e

In this eto the Gconnecte

ALLATION G

THE EVENT O controller contdrives in G-SPEe alarm will soudrive and its ph

G-SPEED eS was co5 or 10), a drive fhe array is now in d be replaced as so

below to identi

web GUI.

arm by clicking

ll display inforation mark on tStatus” of the

the GUI indeS unit has faile

xample there are t-Tech RAID controed to Port 2 of the

UIDE - Windo

OF A DISK DRItinually monitoEED eS. In the und. The web hysical position

onfigured in a protfailure does not re an unprotected stoon as possible to

fy and replace

g on the <Beepe

mation like thathe G-SPEED e array is Criticates which

ed.

two G-SPEED eS unller. Drive 3 of the G-Tech RAID contr

ows

IVE FAILURE rs the health of event of a diskGUI will also

n.

tected RAID mode esult in data loss. tate and the failed avoid data loss.

a failed drive.

er Mute>

at shown beloweS icon indicateical. The lowedrive in whic

nits connected G-SPEED eS roller has failed.

f k

w. es er ch

4. Remove the fG-SPEED eS controller) byand gently slid

WARNdrive connefollowconne

REMO

LOSSON G

X

failed drive (In connected to

y inserting the pding the drive m

NING: Make absoindicated by the G

ected to the G-Tecw the cable to ensuected to on the RAI

OVING THE WRONS OF THE ARRAY A-SPEED eS.

n this exampleo port 2 of thprovided key inmodule out of t

lutely sure that yoGUI. If multiple G-h RAID controller, re you know which

ID controller.

NG DRIVE WILL RAND ALL OF THE

Page

e Drive 3, of the G-Tech RAn to the lock hothe enclosure.

ou remove the faile-SPEED eS units ar it is a good idea th Port # the array

RESULT IN THE CONTENT STORE

e 19

he ID ole

ed re to is

ED

Page 20: G-SPEED™ eS Windows Installation Guide

G-SPE

5. RiiRT

6. O

N

12. TEC

Ifplfo

Wofav

EED eS INSTA

Replace the fain place. Oncendicate that tRebuilding anThe rebuild tim

Once the rebuilNormal and pr

CHNICAL SUPf y u encounto elease contact ollowing ways:

phonTele eFax: (310E-mail: sInternet:

When contactingf your computevailable:

• r G-S• atin You Oper g• Compute• eSATA ho• Amount o• Other dev

ALLATION G

led drive with the drive has he array is red the percentae is approxima

ld is complete, rotecting your v

PORT er any difficultG-Tech Techn

e: (310) 449-40) 449-4670 upport@g-tech http://www.g-

g Technical Super and have th

PEED eS serial g system and vr brand and mo

ost adapter branof memory instvices attached

UIDE - Windo

a new disk mospun up to spe

ebuilding (The age complete) ately 2 hours pe

G-SPEED eS isvaluable data o

ties while instical Support v

4599

hnology.com -technology.com

pport, make sue following info

number (on boversion odel nd and model alled to your comput

ows

odule and secureed, the GUI w“Status” show

as shown belower TB.

s back to nce again.

alling G-SPEEDvia one of th

m/support

re to be in fronormation readi

ottom of unit)

ter

re ill

ws w.

D, he

nt ly

13. LIGausGRortPasMtGboewG

FaG( ITRPDDITHTI

IMITED WARRG-Technology Iany defect in use, for the deshould becomeG-Tech, will at iRepair or replaon an exchanreconditioned. the Property of Product has beas a result of service is availaMaterial Authothe Product duG-Tech service bear all shippiother costs, eeffe te rectua pwarranty. All G-Tech in the o

For more informan RMA numbeG-Tech at 1653(310) 449-4599 IN THE EVENT THE WARRANTREMEDY SHALPROVIDED ABODAMAGES, INCDATA, ARISINGIMPLIED WARRTECH AND, TOHEREBY EXCLUTO THE EXTENTINJURY DAMAG

RANTY nc. (G-Tech) wmaterial and wesignated warre defective wits discretion, rcement parts onge basis an All replaced pa G-Tech. This wen damaged by unauthorized able to the purcrization numbe

uring the warra facility or to ing, packing aexcluding partpair, replaceme

returned Prodriginal shipping

mation on hower or to acquire3 Stanford Stre9 or support@g

A PRODUCT BETY PERIOD, THLL BE REPAIOVE. INCIDENCLUDING WITHG FROM BREAANTY ARE NOT

O THE EXTENTUDED BOTH FOT NOT UNCON

GE.

warrants your Pworkmanship, ranty period. within the warrepair or replacor Products wild will be ei

arts or Productswarranty shall ny accident, mis service or pachaser by obtaer (RMA) and anty period to G-Tech. The p

and insurance s and labor, ent or refundduct must beg container.

w to obtain ware shipping matet, Santa Moni

g-technology.co

ECOMES DEFECE PURCHASERIR OR REPLANTAL OR CONSHOUT LIMITATIACH OF ANY T THE RESPONST PERMITTED OR PROPERTY DSCIONABLE, FO

Page

roduct against under normal If the Product rranty period, ce the Product. ll be furnished ther new or s shall become not apply if the suse, abuse or arts. Warranty ining a Return by delivering an authorized urchaser shall costs and all necessary to

d under this e shipped to

rranty service, terials, contact ca, CA 90404,

om.

CTIVE DURING R’S EXCLUSIVE ACEMENT AS SEPROUENTAL ION LOSS OF EXPRESS OR

SIBILITY OF G-BY LAW, ARE DAMAGE, AND OR PERSONAL

e 20

Page 21: G-SPEED™ eS Windows Installation Guide

G-SPE

APPE

1

2

3

4

5

6

EED eS INSTA

ENDIX A: WEB

1. Manage: Array: Thisweb GUI. Gfrom this paDevices: Hpage (you page as tperformancSpare Poodrives can bcalled hot sadded to th

2. Events: Allrecorded heThese evennotification

3. Tauvo

asks: Schtomaticallume.

4. Settings: settings snotification.

5. Driv e Stath rd drivesa

6. o L gout: Sa

ALLATION G

B GUI

s is the main G-SPEED eS is age. (See Appe

Hard drive paramshould not m

the drives aree with the G-SP

ol: When confbe assigned to spare). These de Array in the e

events of the ere, such as ants can be em under the “Set

edule the G-Teinly verify the t

Configure theuch as logi. See Appendix

tus: Check th including detai

ay goodbye

UIDE - Windo

screen of the configured anendix A.1 for demeters are mod

make any chane configured PEED eS. figured in prot a “spare pool”drives will be aevent of a drive

G-SPEED eS carray changes mailed by settinttings” tab.

ch controller totegrity of the R

e G-SPEED en password x A.4 for details

e status of ailed SMART dat

ows

G-SPEED eS nd monitored etails) dified on this nges on thi

for optims al

tected mode ” (sometimes automatically e failure.

controller are and failures. ng up email

o RAID

S controllerand email

s

ll connected ta.

A.1 M age: an A

1. Name: A

2. Type: Di

3. Capacity

4. Cache P

for RAIDappendix

5. OS Namdisplay in

6. Status: DNormaCriticaInitialRebui

Array

Array name (as

splays RAID lev

y: you guessed

Policy: DisplayD protected ax B.1.7.7

me: Controllern Disk Utility.

Displays currenal: All systemsal: Drive failurelizing: Buildingilding: Parity d

shown in GUI

vel of array.

it… capacity of

s current writearrays. For m

r assigned na

nt status of arra go e has occurred g RAID 1, 5 or ata being recon

Page

only).

f the array.

e cache policy more info see

ame that will

ay.

10 array nstructed

e 21

Page 22: G-SPEED™ eS Windows Installation Guide

G-SPE

7.

EED eS INSTA

Maintenanceoptions for cuon RAID level

RAID 0

7 1. Delete: D

WARNTHE A

7.2 Unplugcontroller. Boption. This system witho

NOTE: recommdisconne

7.3 Rename

ALLATION G

e: Displays conurrent array. Thl of the array.

Deletes current

NING: THIS ARRAY AND AL

: This will disBe sure to cloenables the arut causing an a

While the contmend shutting the ecting G-SPEED eS

: Renames arra

UIDE - Windo

figuration and he options diffe

t Array

OPERATION LL DATA ON I

sconnect the Aose all files berays to be unpalarm.

troller is “hot psystem down whe

S from the controlle

ay as displayed

ows

maintenance er depending

WILL DELETT!!

Array from theforelugged f

using throm th

pluggable,” we n connecting or er.

in the GUI.

TE

he is

he

7.4 OCE/ORLOnline Cacapacity oG-SPEED eOnline RAthe RAID

7.5 Shows the

location an

“Devic

RAID 5

7.6 Verify: Ve 7.7 Change CRAID 5 arrays.

Write-bis cachebut datfailure. Write-talways reads mappropr

LM: pacity Expansio

of an existing areS units are ad

AID Level Migralevel of an exis

e devices currend status.

ce_Controller

erifies the integ

Cache Policy: .

back: (Defaulted. This will resta loss may o through: Dat passed directlymay still be comriate

on: It is possibrray when addidded to the systation: it is posssting array.

ently part of t

r#_Port#_Driv

grity of the RAID

This option is

t) Data written sult in higher poccur in case

a written to ty to the disks. mpleted from t

Page

le to expand thtional tem. sible to change

the Array, their

ve#”

D set.

or available f

to the array performance, of a power

the array is Subsequent the cache, if

e 22

he

r

Page 23: G-SPEED™ eS Windows Installation Guide

G-SPE

8. C

C

EED eS INSTA

Create Array Click on “Create

ALLATION G

Array” and the

UIDE - Windo

e following will

ows

appear.

8

8

8

8

8

8

8

8

.1 Array Type

.2 Array Namthe MAIN pa

.3 Initializatiocreation pro

Foregroucreation pcomplete. Backgroufor the creimmediate

NOTunti

.4 Cache Polic

a RAID 5 ar

Write-backwill result inoccur in caseWrite-throupassed direcstill be comp

All:.5 Select

.6 Available Dfor array cserial numbcapacity.

ocation:

ilable

L .7 Ava D

newavai

.8 Cre

array.lable.

ate: Asarray creatio

e: select the RA

me: This is theage of the GUI.

on Method: Seocess.

und: All controlprocess and th

und: Minimal eation process e use.

TE: RAID protectiol initialization is co

cy: This optionrray.

: Data written tn higher perfore of a power faiugh: Data writctly to the diskleted from the

Simple method

Disks: Displaycreation, showiber, size of th

“Controller#

Disks: Enter t Default is

s expected, seon process.

AID level for new

name that wi

ets the priority

ller resources ahe array is not

controller reso and the array

n is not available mplete

n is available w

to the array is mance, but dailure. tten to the arraks. Subsequent cache, if appro

d to select all di

ys disks currening location, dhe disk and c

#/Port#/Drive

the desired caps the Maximu

electing this wi

Page

w array

ill be displayed

of the RAID

are used for tht available unt

ources are usey is available fo

hen creating

cached. This ata loss may

ay is always t reads may opriate

isks.

ntly available drive model, current free

e#”

pacity of the um capacity

ill begin the

e 23

d in

he til

ed or

Page 24: G-SPEED™ eS Windows Installation Guide

G-SPE

9. Lo

co

Lo

10. Modis

11. Cacu

12. Madis

13. Rede

14. Be

EED eS INSTA

ocation: Showntroller.

ocation: “Contr

odel: Displayssks currently at

apacity: Displarrently attache

ax Free: Dispsks currently at

escan: Rescanevices attached

eeper Mute: M

NOTE: Beepedisconnected “Unplug” in th

ALLATION G

ws the location o

roller#/Port#/

s the drive mottached to the c

ays the advertied to the contro

lays the maximttached to the c

ns the eSATA .

Mutes audible be

er will sound when from the system w

he Array Maintenan

UIDE - Windo

of disks attache

/Drive#”

odel and serial controller.

sed capacity ooller.

mum free capacontroller.

bus to detect

eeper.

a drive fails or an awithout first selectinnce menu.

ows

ed to the

number of

of the disks

acity of the

t any new

array is ng

(This page left inte

entionally blan

Page

nk)

e 24

Page 25: G-SPEED™ eS Windows Installation Guide

G-SPE

Ap

EED eS INSTA

pendix A.4: S

ALLATION G

ettings

UIDE - Windoows

1.

2.

3.

4. 5.

6.

7.

8. 9.

10

Auto Rebuildfeature. Whearray will autinserted. See

Audible Alar Rebuild Priotime dedicatewill rebuild thless responsiv SAF-TE: This

Listening PoG-SPEED webnetwork users

Password: C

SMTP Settinfor email nothere.

Recipients: A

Add Recipienotification. S

InformationWarning: WaError: Error e Test: Sends a

0. HDD Temperof the hard email. Defaucan operate u

d: Enables oren enabled, a tomatically rebe Section 12 for

rm: Enables or

ority: Sets theed to rebuildinghe array faster,ve to the system

s feature is not

ort: The port b GUI. Restri“ cs to access the

Changes login p

ng: Email sertification. Ente

A list of current

ent: Add emSelect Event lev

: Informationaarning events aevents are sent

a test email to

rature Threshdrive temperault is 50°C, houp to 60°C.

r disables the critical RAID 5

build when a nr details.

r disables the a

e amount of cog an array. Hi however the am.

currently suppo

used to conct to local acce GUI. Default i

password. Defau

rver informatioer your server

t email recipien

mail addressesvel to trigger a

l events are seare sent t

the new accoun

hold: Adjusts tture to triggeowever today’s

Page

auto-rebuild 5 or RAID 1 new drive is

udible alarm

ontroller CPU gher Priority array will be

orted.

to the nect ess” disables is Port 7402.

ult is 0000

on necessary information

nts.

s for email n email.

nt

nt

he threshold r a warning

s disk drives

e 25

Page 26: G-SPEED™ eS Windows Installation Guide

G-SPEED eS INSTALLATION GUIDE - Windows

Page 26

APP plained

RAID Level Description Advantage Disadvantage Ideal For…

ENDIX B: RAID levels ex

0 Disk striping Offers the highest performance and a useable storage capacity of 100% of total available storage capacity

No fault tolerance - failure of one drive in the array results in complete data loss

Content creation applications requiring highest storage capacity

1 Mirroring Maximum level of data protection as identical data is written to multiple drives

Useable storage space is 50% of total available capacity

Applications in which data security is paramount

5 Disk striping with distributed parity

High read performance, medium write performance with data protection in case of a drive failure.

Useable storage capacity equals total capacity of all drives in the array less the capacity of one drive. For example, a 4x 1TB RAID 5 yields a useable capacity of 3 TB. Disk failure results in slight drop in performance

Content creation applications requiring data protection

10 Mirror of striped drive pairs

Higher performance than RAID 1 with same level of data protection.

Useable storage space is 50% of total available capacity

Content creation applications requiring data protection

JBOD Just-a-bunch-of-disks

Each drive can be accessed as an individual volume. Useable storage capacity is 100% of total available storage.

No fault tolerance Audio applications

Wm

U

w

APPENDIX C: Notes

hen the G-Tech web GUI is open dropped frames ay occur in editing applications such as Final Cut

ro and Premiere Pro. We recommend not having the GUI open while working in these progrP

ams. It is recommended not to exceed the standard eSATA cable length of 1 meter (3 feet).

p to (4) G-SPEED eS storage units can be attached o the G-Tech RAID controller for up to 16TB of

capacity and over 600 MB/sec of pt

erformance. eplacements / extra G-SPEED eS disk modules are R

available for purchase online at: ww.g-technology.com/products/g-speed-es.cfm

Page 27: G-SPEED™ eS Windows Installation Guide

G-SPE

APPENDisk Ma

1

2.

EED eS INSTA

DIX D: Formaanagement

1. Open Disk MComputer> “Manage.

Select “Disk M

ALLATION G

atting G-SPEED

Management by from the Start

anagement”

UIDE - Windo

D eS using W

y right clicking t Menu and sele

ows

indows XP

on <My ectin

g

3.

4.

. The “Initializaccept all the

. When the W

eS listed as show the capbar as shown

e Wizard” will ae default values

Wizard completeDisk X (in this pacity and “Unn and select “N

appear. Click <s.

es you will see example Disk allocated.” Rigew Partition.”

Page

<Next> and

e the G-SPEED1). It will also

ght click on the

e 27

D o e

Page 28: G-SPEED™ eS Windows Installation Guide

G-SPEED eS INSTALLATION GUIDE - Windows

Pag

gPa e 28

cepting the default values. When t r the values as shown. at” and then click <Next>.

7. he Wizard will complete and bring you back to t e Main isk Management screen. The G-SPEED eS will format in

ust a few seconds and be ready to use!

(This page left intentionally blank)

G-SPEED eS INSTALLATION GUIDE - Windows

5. The “New Partition Wizard” will open, click <Next>.

6. Follow the prompts, acyou reach this screen, ene ct “Perform a quick form

T hDj

eS le