GRAVITY LOADS: DEAD LOADS S = S = S = S = I = S 1 DS D1 DC - 4 DC - 6 WIND DESIGN: DC DC - 1 DESIGN CRITERIA DC - 2 DC - 3 LIVE LOADS SEISMIC DESIGN: THE STRUCTURE HAS BEEN EVALUATED IN ACCORDANCE WITH THE CALIFORNIA BUILDING CODE. DC - 5 ALLOWABLE NET SOIL PRESSURE COEFFICIENT OF FRICTION PASSIVE RESISTANCE *ALLOWABLE SOIL BEARING PRESSURES ARE FOR FOOTINGS HAVING A DEPTH EQUAL TO NEW SOIL RETAINING STRUCTURES HAVE BEEN DESIGNED WITH THE FOLLOWING CRITERIA. ACTIVE/PASSIVE EQUIVALENT FLUID PRESSURES: RESTRAINED RETAINING WALLS =65 PCF CANTILEVERED WALL (12' MAX) =45 PCF FOUNDATION DESIGNS ARE IN ACCORDANCE WITH RECOMMENDATIONS SHALLOW FOUNDATIONS MIN PILE DIAMETER =24" PILE EMBED INTO BEDROCK =10' (FIXITY AT 3') SKIN FRICTION =700 PSF (1/3 INCREASE FOR SHORT DURATION LOADING) FILL DOWNHILL CREEP =1000 PCF PASSIVE EARTH PRESSURE =400 PCF MAX ALLOWABLE EARTH PRESSURE =6000 PSF FRICTION PILES FOUNDATION DESIGNS ARE IN ACCORDANCE WITH THE MINIMUM DESIGN RECOMMENDATIONS FOUND IN CHAPTER 18 OF THE CALIFORNIA BUILDING CODE. ROOF = 44 PSF (REDUCIBLE) UPPER LEVEL = 14 PSF MAIN LEVEL = 14 PSF ROOF = 20 PSF (REDUCIBLE) UPPER LEVEL = 40 PSF TYP, 60 PSF AT BALCONY MAIN LEVEL = 40 PSF TYP, 60 PSF AT BALCONY 2.423 0.869 1.615 1.304 1.0 FOR OCCUPANCY CATEGORY (II) SEISMIC DESIGN CATEGORY = E SITE CLASS = D ANALYSIS PROCEDURE = EQUIVALENT LATERAL FORCE RHO = 1.3 LFRS = SPECIAL CONCRETE SHEAR WALLS R = 5.0 OVERSTRENGTH = 2.5 Cs = 0.323 BASIC WIND SPEED, V = 110MPH (3 SECOND GUST) EXPOSURE CATEGORY = B GUST EFFECT FACTOR = 0.85 Kd = 0.85 ENCLOSURE CLASSIFICATION = ENCLOSED LFRS = TIMBER SHEAR WALLS R = 5.0 OVERSTRENGTH = 2.5 Cs = 0.323 APPLICABLE CODE: 2016 CALIFORNIA BUILDING CODE PROJECT TYPE: NEW SINGLE FAMILY RESIDENTIAL =3000 PSF =0.5 =400 PCF 18". PROVIDED IN "GEOLOGIC AND SOILS ENGINEERING EXPLORATION PROPOSED RESIDENCE AND POOL" DATED OCT, 3, 2018 BY IRVINE GEOTECHNICAL. THOMAS CALUS 1620 SUMMITRIDGE DRIVE, BEVERLY HILLS, CA 90210 SUD date sheet title sheet number revisions client drawn by date f: e: 310. 424.5230 p: 310.929.7815 [email protected] 915 mateo street suite 205 los angeles ca 90021 www.domaen.net EXP 03/31/2019 C80463 S T A T E O F C A L I F O R N I A E L I Z A B E H M A H L O W R E G I S T E R E D P R O F E S S I O N A L E N G I N E E R C I V I L T 600 WILSHIRE BLVD, SUITE 760 LOS ANGELES, CA 90017 213 627 6687 [email protected] NOT FOR CONSTRUCTION GENERAL NOTES, ABBREVIATIONS, & SHEET LIST S0.00 Author 01/04/19 ABBREVIATIONS HORIZ HORIZONTAL INT INTERIOR LWC LIGHTWEIGHT CONCRETE MAX MAXIMUM MECH MECHANICAL MFR MANUFACTURER MIN MINIMUM NO. OR # NUMBER NS NEAR SIDE OC ON CENTER OH OPPOSITE HAND OMF ORDINARY MOMENT FRAME PC PILE CAP PEN PENETRATION PJP PARTIAL JOINT PENETRATION PL PLATE RC REINFORCED CONCRETE REINF REINFORCEMENT OR REINFORCING STEEL REQ'D REQUIRED SCBF SPECIAL CONCENTRICALLY BRACED FRAME SCHED SCHEDULE SHTHG SHEATHING SIM SIMILAR SMRF SPECIAL MOMENT RESISTING FRAME SOG SLAB ON GRADE STD STANDARD SYM SYMMETRIC T TOP BAR(S) T&B TOP AND BOTTOM T.O. TOP OF THK THICK / THICKNESS TOC TOP OF CONCRETE TOD TOF OF DECK TOF TOP OF FOOTING TOFR TOP OF FRAMING TOG TOP OF GRADE TOPC TOP OF PILE CAP TOS TOP OF STEEL TOW TOP OF WALL TYP TYPICAL UON UNLESS OTHERWISE NOTED VERT VERTICAL WP WORK POINT ABBREVIATIONS (E) EXISTING (N) NEW [UP] UPSTANDING BEAM [VIF] VERIFY IN FIELD AB ANCHOR BOLT ARCH ARCHITECTURAL B BOTTOM BAR(S) BLKG BLOCKING BM BEAM BN BOUNDARY NAILING BOE BASE OF EXCAVATION BOT BOTTOM CA COLUMN ABOVE CB COLUMN BELOW CJP COMPLETE JOINT PENETRATION CL CENTERLINE CLR CLEAR COL COLUMN CONC CONCRETE CONN CONNECTION CONT CONTINUOUS DBL DOUBLE DEG DEGREE(S) DIA DIAMETER DWG DRAWING EA EACH EF EACH FACE ELEV ELEVATION EMBED EMBEDDED OR EMBEDMENT EN EDGE NAILING EQ EQUAL ES EACH SIDE EW EACH WAY EXT EXTERIOR FDN FOUNDATION FG FINISHED GRADE FN FIELD NAILING FS FAR SIDE FTG FOOTING GA GAUGE GB GRADE BEAM HDR HEADER HGR HANGER SU SUBMITTALS SU-1 SUBMITTAL REVIEW FOR ITEMS DESIGNED BY NOUS, 10 BUSINESS DAY REVIEW TIME IS REQUIRED UNLESS OTHERWISE AGREED. SU-2 RFI REVIEW: ALLOW 5 BUSINESS DAY RESPONSE UNLESS OTHERWISE AGREED. SU-3 SUBMIT COPIES OF REQUIRED SUBMITTALS TO OWNER'S REPRESENTATIVE FOR REVIEW. SU-4 CONCRETE REINFORCING STEEL: - A. SUBMIT CERTIFIED MATERIAL CERTIFICATES FOR REINFORCING STEEL SIGNED BY THE MANUFACTURER AND CONTRACTOR. - B. SUBMIT SHOP DRAWINGS FOR FABRICATION, BENDING AND PLACEMENT OF CONCRETE REINFORCEMENT IN ACCORDANCE WITH ACI 315 "DETAILS AND DETAILING OF CONCRETE REINFORCEMENT." SU-5 CAST-IN-PLACE CONCRETE: - A. SUBMIT MIX DESIGNS PREPARED, STAMPED AND SIGNED BY A PROFESSIONAL ENGINEER REGISTERED IN THE STATE OF CALIFORNIA FOR EACH CLASS OF CONCRETE. INCLUDE RESULTS OF SLUMP, SHRINKAGE AND COMPRESSION TESTS USED TO ESTABLISH MIX PROPORTIONS. ALSO INCLUDE CERTIFIED MATERIAL CERTIFICATES FOR EACH COMPONENT OF THE MIX. - B. SUBMIT PROPOSED CONSTRUCTION JOINT LOCATIONS FOR REVIEW. - C. SUBMIT PRODUCT DATA FOR CURING MATERIALS. - D. SUBMIT PRODUCT DATA FOR NON-SHRINK GROUT. SU-6 STRUCTURAL STEEL: - A. SUBMIT MILL CERTIFICATES FOR STRUCTURAL STEEL SHAPES INDICATING STRUCTURAL STRENGTH AND CHEMICAL COMPOSITION FOR EACH HEAT OF STEEL - B. SUBMIT SHOP DRAWINGS PRIOR TO FABRICATION. INCLUDE AT A MINIMUM ASTM MATERIAL DESIGNATIONS, MEMBER SIZES, SIZES AND TYPES OF WELDS, SIZES AND TYPES OF BOLTS AND DIMENSIONS. - C. SUBMIT MILL CERTIFICATES FOR FASTENERS AND THREADED RODS. - D. SUBMIT WELDING PROCEDURE SPECIFICATION FOR EACH TYPE OF WELD TO BE USED AND PRODUCT DATA FOR WELDING ELECTRODES. - E. SUBMIT MANUFACTURERS PRODUCT DATA FOR PRIMER AND FINISH PAINT INCLUDING COLOR CHARTS. SU-7 MECHANICAL ANCHORS: SUBMIT PRODUCT DATA FOR EACH TYPE OF ANCHOR USED. SU-8 ADHESIVE ANCHORS: SUBMIT PRODUCT DATA FOR EACH TYPE OF ADHESIVE ANCHORING SYSTEM USED. GR GENERAL REQUIREMENTS GR-1 MATERIALS AND WORKMANSHIP TO CONFORM WITH THE 2016 EDITION OF THE CALIFORNIA BUILDING CODE, WITH CITY OF LOS ANGELES AMENDMENTS AND THE REQUIREMENTS OF THE CONTRACT DOCUMENTS. GR-2 REFERENCE TO CODES, RULES, REGULATIONS, STANDARDS, MANUFACTURER'S INSTRUCTIONS OR REQUIREMENTS OF REGULATORY AGENCIES IS TO THE LATEST PRINTED EDITION OF EACH IN EFFECT AT THE DATE OF SUBMISSION OF BID UNLESS THE DOCUMENT DATE IS SHOWN. GR-3 VERIFY ALL DIMENSIONS, ELEVATIONS, & SITE CONDITIONS BEFORE STARTING WORK. NOTIFY STRUCTURAL ENGINEER OF DISCREPANCIES. GR-4 REFER TO ARCHITECTURAL & CIVIL DRAWINGS FOR EXTERIOR SLABS. GR-5 DRAWINGS INDICATE GENERAL AND TYPICAL DETAILS OF CONSTRUCTION. WHERE CONDITIONS ARE NOT SPECIFICALLY INDICATED BUT ARE OF SIMILAR CHARACTER TO DETAILS SHOWN, USE SIMILAR DETAILS OF CONSTRUCTION, SUBJECT TO REVIEW BY THE OWNER'S REPRESENTATIVE. GR-6 THE CONTRACTOR IS RESPONSIBLE FOR COORDINATING THE WORK OF ALL TRADES AND FOR CHECKING DIMENSIONS. NOTIFY THE OWNER'S REPRESENTATIVE OF ANY DISCREPANCIES AND RESOLVE BEFORE PROCEEDING WITH THE WORK. GR-7 DO NOT SCALE THE DRAWINGS. GR-8 PROVIDE MEASURES NECESSARY TO PROTECT THE STRUCTURE DURING CONSTRUCTION. SUCH MEASURES INCLUDE, BUT MAY NOT BE LIMITED TO, BRACING AND SHORING FOR LOADS DURING CONSTRUCTION. RETAIN A REGISTERED CIVIL ENGINEER WHOM IS PROPERLY QUALIFIED TO DESIGN BRACING, SHORING, ETC. VISITS TO THE SITE BY THE OWNER'S REPRESENTATIVE WILL NOT INCLUDE OBSERVATION OF THE ABOVE NOTED ITEMS. GR-9 REFER TO ARCHITECTURAL DRAWINGS FOR SIZE AND LOCATION OF FLOOR, ROOF AND WALL OPENINGS NOT SHOWN ON THE STRUCTURAL DRAWINGS. COORDINATE THE SIZE AND LOCATION OF OPENINGS ASSOCIATED WITH, BUT NOT LIMITED TO, ELECTRICAL, MECHANICAL AND PLUMBING TRADES. SUBMIT FINAL SIZING AND LOCATION REQUIREMENTS OF OPENINGS TO THE OWNER'S REPRESENTATIVE FOR REVIEW. GR-10 THE CONTRACTOR IS SOLELY RESPONSIBLE FOR PROVIDING A SAFE PLACE TO WORK AND MEETING THE REQUIREMENTS OF ALL APPLICABLE JURISDICTIONS. EXECUTE WORK TO ENSURE THE SAFETY OF PERSONS AND ADJACENT PROPERTY AGAINST DAMAGE BY FALLING DEBRIS AND OTHER HAZARDS IN CONNECTION WITH THIS WORK. FN FOUNDATION AND SITE WORK FN-1 GROUNDWATER WAS NOT ENCOUNTERED DURING EXPLORATION AND IS NOT EXPECTED TO BE A FACTOR IN DEVELOPMENT OF SITE. FN-2 LOCATE AND PROTECT EXISTING UTILITIES TO REMAIN DURING AND/OR AFTER CONSTRUCTION. FN-3 REMOVE ABANDONED FOOTINGS, UTILITIES, ETC. WHICH INTERFERE WITH NEW CONSTRUCTION, UNLESS OTHERWISE INDICATED. FN-4 NOTIFY THE OWNER'S REPRESENTATIVE IF ANY BURIED STRUCTURES NOT INDICATED, SUCH AS CESSPOOLS, CISTERNS, FOUNDATIONS, ETC., ARE FOUND. FN-5 THE CONTRACTOR IS SOLELY RESPONSIBLE FOR EXCAVATION PROCEDURES INCLUDING LAGGING, SHORING, UNDERPINNING AND PROTECTION OF EXISTING CONSTRUCTION. FN-6 REMOVE LOOSE SOIL AND STANDING WATER FROM FOUNDATION EXCAVATIONS PRIOR TO PLACING CONCRETE. FN-7 EXCAVATIONS FOR FOUNDATIONS MUST BE ACCEPTED BY THE GEOTECHNICAL ENGINEER PRIOR TO PLACING REINFORCING AND CONCRETE. NOTIFY THE GEOTECHNICAL ENGINEER WHEN EXCAVATIONS ARE READY FOR INSPECTION. FN-8 PLACE BACKFILL BEHIND RETAINING WALLS AFTER CONCRETE OR MASONRY HAS ATTAINED FULL DESIGN STRENGTH. BRACE BUILDING AND PIT WALLS BELOW GRADE FROM LATERAL LOADS UNTIL ATTACHED FLOORS AND SLABS ON GRADE ARE COMPLETE AND HAVE ATTAINED FULL DESIGN STRENGTH. FN-9 COMPACT EXCAVATION BACKFILLS IN LAYERS PER THE GEOTECHNICAL REPORT. FIELD OBSERVATION AND TESTING SHALL BE PERFORMED BY THE SOILS ENGINEER DURING GRADING TO ASSIST THE CONTRACTOR IN OBTAINING THE REQUIRED DEGREE OF COMPACTION AND PROPER MOISTURE CONTENT. FN-10 IF ADVERSE SOIL CONDITIONS ARE ENCOUNTERED, NOTIFY GEOTECHNICAL ENGINEER AND ADDITIONAL SOILS REPORT MAY BE REQUIRED. STRUCTURAL DRAWING LIST Sheet Number Sheet Name 000 GENERAL NOTES - BASE _SH0.00* SHORING GENEREAL NOTES BASE NE_REFERENCE SS2.2 TYPICAL FRAMING PLAN SS2.3 TYPICAL SHEAR WALL & POST PLAN S0 SERIES: SHEET LIST, GENERAL NOTES, TYPICAL DETAILS S0.00 GENERAL NOTES, ABBREVIATIONS, & SHEET LIST S0.01 GENERAL NOTES S0.10 TYPICAL CONCRETE DETAILS - REBAR S0.11 TYPICAL CONCRETE DETAILS - FOUNDATIONS & SLAB ON GRADE S0.12 TYPICAL CONCRETE DETAILS - ELEVATED SLAB REINFORCING S0.13 TYPICAL CONCRETE DETAILS - WALL REINFORCING & COLUMNS S0.30 TYPICAL WOOD DETAILS - GENERAL FRAMING & STUD WALLS S0.31 TYPICAL WOOD DETAILS - SHEAR WALLS S0.32 TYPICAL WOOD DETAILS - HORIZONTAL DIAPHRAGMS S1 SERIES: RETAINING WALL PLAN S1.00 RETAINING WALL PLAN S2 SERIES: FOUNDATION PLAN, FRAMING PLAN, AND SLAB REINFORCING PLANS S2.00 BASEMENT FOUNDATION PLAN S2.01 MAIN LEVEL FRAMING PLAN S2.01R MAIN LEVEL REINFORCEMENT PLAN S2.02 UPPER LEVEL FRAMING PLAN S2.02R UPPER LEVEL REINFORCEMENT PLAN S2.03 ROOF FRAMING PLAN S3 SERIES: LATERAL FRAME ELEVATIONS AND BUILDING SECTIONS S3.00 BUILDING SECTIONS S3.01 BUILDING SECTIONS S3.02 BUILDING SECTIONS S3.10 STAIR PLANS AND DETAILS S4 SERIES: POOL SUPPORT S4.00 POOL PLANS AND SECTIONS S5 SERIES: PROJECT SPECIFIC DETAILS S5.00 PROJECT SPECIFIC DETAILS SH SERIES: SHORING NOTES, DETAILS, PLANS SH0.00 SHORING GENERAL NOTES SH0.10 TYPICAL SHORING DETAILS SH1.00 SHORING PLAN IO STRUCTURAL TEST AND INSPECTIONS IO-1 AN INDEPENDENT TESTING AGENCY AND SPECIAL INSPECTORS WILL BE RETAINED BY THE OWNER TO PERFORM THE FOLLOWING TESTS AND INSPECTION. PROVIDE ACCESS AND FURNISH SAMPLES TO THE AGENCY AS REQUIRED BY THE CONTRACT DOCUMENTS. IO-2 CONTRACTORS RESPONSIBLE FOR THE CONSTRUCTION OF A WIND OR SEISMIC FORCE RESISTING SYSTEM/ COMPONENT AS LISTED IN THE "STATEMENT OF SPECIAL INSPECTION" SHALL SUBMIT A WRITTEN STATEMENT OF RESPONSIBILITY TO THE LADBS INSPECTORS AND THE OWNER PRIOR TO THE COMMENCEMENT OF WORK ON SUCH A SYSTEM OR COMPONENT PER 1704.4. IO-3 IF INITIAL TESTS OR INSPECTIONS MADE BY THE OWNER'S TESTING AGENCY REVEAL THAT ANY PORTION OF THE WORK DOES NOT COMPLY WITH THE CONTRACT DOCUMENTS, ADDITIONAL TESTS, INSPECTIONS, AND NECESSARY REPAIRS WILL BE MADE AT THE CONTRACTOR'S EXPENSE. IO-4 THE FOLLOWING ITEMS REQUIRE TESTS AND INSPECTIONS IN ACCORDANCE WITH THE REQUIREMENTS OF THE CHAPTER "STRUCTURAL TEST AND INSPECTIONS" OF THE CODE OF THE GOVERNING JURISDICTION AS NOTED IN THE GENERAL SECTION OF THESE GENERAL NOTES. AN "X" PRESENT IN COLUMN "C" INDICATES CONTINUOUS INSPECTION & "X" PRESENT IN COLUMN "P" INDICATES PERIODIC INSPECTION. CAST IN PLACE DEEP FOUNDATIONS VERIFICATION AND INSPECTION C P 1. 1.OBSERVE DRILLING OPERATIONS AND MAINTAIN COMPLETE AND ACCURATE RECORDS FOR EACH ELEMENT. X - 2. VERIFY PLACEMENT LOCATIONS AND PLUMBNESS, CONFIRM ELEMENT DIAMETERS, BELL DIAMETERS (IF APPLICABLE), LENGTHS, EMBEDMENT INTO BEDROCK (IF APPLICABLE) AND ADEQUATE END BEARING STRATA CAPACITY, RECORD CONCRETE OR GROUT VOLUMES. X - 3. FOR CONCRETE ELEMENTS, PERFORM ADDITIONAL INSPECTIONS IN ACCORDANCE WITH SECTION 1704.4. - - CONCRETE VERIFICATION AND INSPECTION C P 1. INSPECTION OF REINFORCING STEEL, PRESTRESSING TENDONS, AND PLACEMENTS. - X 2. INSPECTION OF REINFORCING STEEL WELDING IN ACCORDANCE WITH TABLE 1704.3 ITEM 5B OF IBC/CBC. - - 3. INSPECTION OF BOLTS TO BE INSTALLED IN CONCRETE PRIOR TO AND DURING PLACEMENT OF CONCRETE WHERE ALLOWABLE LOADS HAVE BEEN INCREASED OR WHERE STRENGTH DESIGN IS USED. X - 4. INSPECTION OF ANCHORS INSTALLED IN HARDENED CONCRETE. (i.e. POST INSTALLED ANCHORS). - X 5. VERIFYING USE OF REQUIRED DESIGN MIX. - X 6. AT THE TIME FRESH CONCRETE IS SAMPLED TO FABRICATE SPECIMENS FOR STRENGTH TESTS, PERFORM SLUMP AND AIR CONTENT TESTS AND DETERMINE THE TEMPERATURE OF THE CONCRETE. X - 7. INSPECTION OF CONCRETE AND SHOTCRETE PLACEMENT FOR PROPER APPLICATION TECHNIQUES. X - 8. INSPECTION FOR MAINTENANCE OF SPECIFIED CURING TEMPERATURE AND TECHNIQUES. - X ROUGH CARPENTRY VERIFICATION AND INSPECTION C P 1. SHEARWALL HOLDOWNS AND SILL ANCHORS. - X 2. SHEARWALL NAILING WITH NAIL SPACING LESS THAN 4" OC. - X 3. DIAPHRAGM NAILING WITH NAIL SPACING LESS THAN 4" OC. - X 4. STRAPS AT DIAPHRAGM INSTALLATION. - X SOILS VERIFICATION AND INSPECTION C P 1. VERIFY MATERIALS BELOW SHALLOW FOUNDATION ARE ADEQUATE TO ACHIEVE THE DESIGN BEARING CAPACITY. - X 2. VERIFY EXCAVATIONS ARE EXTENDED TO PROPER DEPTH AND HAVE REACHED PROPER MATERIAL. - X 3. PERFORM CLASSIFICATION AND TESTING OF COMPACTED FILL MATERIALS. - X 4. VERIFY USE OF PROPER MATERIALS, DENSITIES AND LIFT THICKNESSES DURING PLACEMENT AND COMPACTION OF COMPACTED FILL. X - 5. PRIOR TO PLACEMENT OF COMPACTED FILL, OBSERVE SUBGRADE AND VERIFY THAT SITE HAS BEEN PREPARED PROPERLY. - X STRUCTURAL STEEL VERIFICATION AND INSPECTION C P 1. MATERIAL VERIFICATION OF HIGH-STRENGTH BOLTS, NUTS, AND WASHERS: a. MANUFACTURER'S CERTIFICATE OF COMPLIANCE REQUIRED. - X b. IDENTIFICATION MARKINGS TO CONFORM TO ASTM STANDARDS SPECIFIED IN THE APPROVED CONSTRUCTION DOCUMENTS. - X 2. INSPECTION OF HIGH-STRENGTH BOLTING: a. SNUG-TIGHT JOINTS. - X b. PRETENSIONED AND SLIP-CRITICAL JOINTS USING TURN-OF-NUT WITH MATCHMAKING, TWIST-OFF BOLT OR DIRECT TENSION INDICATOR METHODS OF INSTALLATION. - X c. PRETENSIONED AND SLIP-CRITICAL JOINTS USING TURN-OF-NUT WITHOUT MATCHMAKING OR CALIBRATED WRENCH METHODS OF INSTALLATION. X - 3. MATERIAL VERIFICATION OF STRUCTURAL STEEL: a. FOR STRUCTURAL STEEL IDENTIFICATION MARKINGS TO CONFORM TO AISC 360. - X b. FOR OTHER STEEL, IDENTIFICATION MARKINGS CONFORM TO ASTM STANDARDS SPECIFIED IN THE APPROVED CONSTRUCTION DOCUMENTS. - X c. MANUFACTURER'S CERTIFIED TESTS REPORT. - X 4. MATERIAL VERIFICATION OF WELD FILLER MATERIALS: a. IDENTIFICATION MARKINGS TO CONFORM TO AWS SPECIFICATION IN THE APPROVED CONSTRUCTION DOCUMENTS. - X b. MANUFACTURER'S CERTIFICATE OF COMPLIANCE REQUIRED. - X 5. a INSPECTION OF WELDING - STRUCTURAL STEEL: 1. COMPLETE AND PARTIAL JOINT PENETRATION GROOVE WELDS. X - 2. MULTIPASS FILLET WELDS. X - 3. SINGLE-PASS FILLET WELDS > 5/16". X - 4. PLUG AND SLOT WELDS. X - 5. SINGLE-PASS FILLET WELDS < 5/16". - X 6. FLOOR AND ROOF DECK WELDS. - X SO STRUCTURAL OBSERVATIONS SO-1 NOTIFY THE ENGINEER AT SIGNIFICANT CONSTRUCTION STAGES 72 HOURS IN ADVANCE AND PROVIDE ACCESS FOR THE FOLLOWING STRUCTURAL OBSERVATIONS: - A. FOUNDATIONS 1. REINFORCEMENT - B. STEEL FRAMING 1. GENERAL - C. WOOD FRAMING 1. GENERAL 2. SHEAR WALLS AND HOLD-DOWNS 3. DIAPHRAGMS AND COLLECTORS - D. CONCRETE 1. WALL REINFORCEMENT 2. SLABS AND SLABS-ON-GRADE A COPY OF THE LARR AND/OR CONDITIONS OF LISTING SHALL BE MADE AVAILABLE AT THE JOB SITE. 190111 SUD - STRUCTURAL PROGRESS

GENERAL NOTES, ABBREVIATIONS, & SHEET LIST · 2019-07-15 · dc -6 wind design: dc dc -1 design criteria dc -2 dc -3 live loads ... scbf special concentrically braced frame sched

  • Upload
    others

  • View
    4

  • Download
    0

Embed Size (px)

Citation preview

Page 1: GENERAL NOTES, ABBREVIATIONS, & SHEET LIST · 2019-07-15 · dc -6 wind design: dc dc -1 design criteria dc -2 dc -3 live loads ... scbf special concentrically braced frame sched

GRAVITY LOADS:

DEAD LOADS

S =S =S =S =I =

S

1

DS

D1

DC-4

DC-6 WIND DESIGN:

DC

DC-1

DESIGN CRITERIA

DC-2

DC-3

LIVE LOADS

SEISMIC DESIGN:THE STRUCTURE HAS BEEN EVALUATED IN ACCORDANCE WITH THE CALIFORNIA BUILDING CODE.

DC-5

ALLOWABLE NET SOIL PRESSURECOEFFICIENT OF FRICTION PASSIVE RESISTANCE

*ALLOWABLE SOIL BEARING PRESSURES ARE FOR FOOTINGS HAVING A DEPTH EQUAL TO

NEW SOIL RETAINING STRUCTURES HAVE BEEN DESIGNED WITH THE FOLLOWING CRITERIA.

ACTIVE/PASSIVE EQUIVALENT FLUID PRESSURES:RESTRAINED RETAINING WALLS =65 PCF

CANTILEVERED WALL (12' MAX) =45 PCF

FOUNDATION DESIGNS ARE IN ACCORDANCE WITH RECOMMENDATIONS

SHALLOW FOUNDATIONS

MIN PILE DIAMETER =24"PILE EMBED INTO BEDROCK =10' (FIXITY AT 3')SKIN FRICTION =700 PSF (1/3 INCREASE FOR SHORT DURATION LOADING)FILL DOWNHILL CREEP =1000 PCFPASSIVE EARTH PRESSURE =400 PCFMAX ALLOWABLE EARTH PRESSURE =6000 PSF

FRICTION PILES

FOUNDATION DESIGNS ARE IN ACCORDANCE WITH THE MINIMUM DESIGN RECOMMENDATIONS FOUND IN CHAPTER 18 OF THE CALIFORNIA BUILDING CODE.

ROOF = 44 PSF (REDUCIBLE)UPPER LEVEL = 14 PSFMAIN LEVEL = 14 PSF

ROOF = 20 PSF (REDUCIBLE)UPPER LEVEL = 40 PSF TYP, 60 PSF AT BALCONYMAIN LEVEL = 40 PSF TYP, 60 PSF AT BALCONY

2.4230.8691.6151.3041.0 FOR OCCUPANCY CATEGORY (II)

SEISMIC DESIGN CATEGORY = ESITE CLASS = DANALYSIS PROCEDURE = EQUIVALENT LATERAL FORCERHO = 1.3

LFRS = SPECIAL CONCRETE SHEAR WALLSR = 5.0OVERSTRENGTH = 2.5Cs = 0.323

BASIC WIND SPEED, V = 110MPH (3 SECOND GUST)EXPOSURE CATEGORY = BGUST EFFECT FACTOR = 0.85Kd = 0.85ENCLOSURE CLASSIFICATION = ENCLOSED

LFRS = TIMBER SHEAR WALLSR = 5.0OVERSTRENGTH = 2.5Cs = 0.323

APPLICABLE CODE: 2016 CALIFORNIA BUILDING CODE

PROJECT TYPE: NEW SINGLE FAMILY RESIDENTIAL

=3000 PSF=0.5=400 PCF

18".

PROVIDED IN "GEOLOGIC AND SOILS ENGINEERING EXPLORATION PROPOSED RESIDENCE AND POOL"DATED OCT, 3, 2018 BY IRVINE GEOTECHNICAL.

TH

OM

AS

CA

LU

S

16

20

SU

MM

ITR

IDG

E D

RIV

E,

BE

VE

RL

Y H

ILL

S, C

A 9

02

10

SU

D

da

tesh

ee

t title

sh

ee

t nu

mb

er

revis

ion

sclie

nt

dra

wn b

y

da

te

f:e

:31

0. 4

24.5

230

p:31

0.92

9.78

15in

fo@

dom

aen.

net

915

mat

eo s

treet

suite

205

los

ange

les

ca

9002

1

ww

w.d

omae

n.ne

t

EXP 03/31/2019C80463

STATE OF CALIFORN IA

ELIZ

ABE H MAHLOW

REG

IST

ERED

PROFESS IONA L ENGIN

EER

C I V IL

T

600

WIL

SH

IRE

BLV

D, S

UIT

E 7

60LO

S A

NG

ELE

S, C

A 9

0017

213

627

6687

CO

NTA

CT

@N

OU

SE

NG

INE

ER

ING

.CO

M

NOT FOR CONSTRUCTION

GE

NE

RA

L N

OT

ES

, AB

BR

EV

IAT

ION

S, &

SH

EE

T L

IST

S0.

00

Aut

hor

01/0

4/1

9

ABBREVIATIONS

HORIZ HORIZONTAL

INT INTERIOR

LWC LIGHTWEIGHT CONCRETE

MAX MAXIMUM

MECH MECHANICAL

MFR MANUFACTURER

MIN MINIMUM

NO. OR # NUMBER

NS NEAR SIDE

OC ON CENTER

OH OPPOSITE HAND

OMF ORDINARY MOMENT FRAME

PC PILE CAP

PEN PENETRATION

PJP PARTIAL JOINT PENETRATION

PL PLATE

RC REINFORCED CONCRETE

REINF REINFORCEMENT OR REINFORCING STEEL

REQ'D REQUIRED

SCBF SPECIAL CONCENTRICALLY BRACED FRAME

SCHED SCHEDULE

SHTHG SHEATHING

SIM SIMILAR

SMRF SPECIAL MOMENT RESISTING FRAME

SOG SLAB ON GRADE

STD STANDARD

SYM SYMMETRIC

T TOP BAR(S)

T&B TOP AND BOTTOM

T.O. TOP OF

THK THICK / THICKNESS

TOC TOP OF CONCRETE

TOD TOF OF DECK

TOF TOP OF FOOTING

TOFR TOP OF FRAMING

TOG TOP OF GRADE

TOPC TOP OF PILE CAP

TOS TOP OF STEEL

TOW TOP OF WALL

TYP TYPICAL

UON UNLESS OTHERWISE NOTED

VERT VERTICAL

WP WORK POINT

ABBREVIATIONS

(E) EXISTING

(N) NEW

[UP] UPSTANDING BEAM

[VIF] VERIFY IN FIELD

AB ANCHOR BOLT

ARCH ARCHITECTURAL

B BOTTOM BAR(S)

BLKG BLOCKING

BM BEAM

BN BOUNDARY NAILING

BOE BASE OF EXCAVATION

BOT BOTTOM

CA COLUMN ABOVE

CB COLUMN BELOW

CJP COMPLETE JOINT PENETRATION

CL CENTERLINE

CLR CLEAR

COL COLUMN

CONC CONCRETE

CONN CONNECTION

CONT CONTINUOUS

DBL DOUBLE

DEG DEGREE(S)

DIA DIAMETER

DWG DRAWING

EA EACH

EF EACH FACE

ELEV ELEVATION

EMBED EMBEDDED OR EMBEDMENT

EN EDGE NAILING

EQ EQUAL

ES EACH SIDE

EW EACH WAY

EXT EXTERIOR

FDN FOUNDATION

FG FINISHED GRADE

FN FIELD NAILING

FS FAR SIDE

FTG FOOTING

GA GAUGE

GB GRADE BEAM

HDR HEADER

HGR HANGER

SU SUBMITTALS

SU-1 SUBMITTAL REVIEW FOR ITEMS DESIGNED BY NOUS, 10 BUSINESS DAY REVIEW TIME IS REQUIRED UNLESSOTHERWISE AGREED.

SU-2 RFI REVIEW: ALLOW 5 BUSINESS DAY RESPONSE UNLESS OTHERWISE AGREED.

SU-3 SUBMIT COPIES OF REQUIRED SUBMITTALS TO OWNER'S REPRESENTATIVE FOR REVIEW.

SU-4 CONCRETE REINFORCING STEEL:

- A. SUBMIT CERTIFIED MATERIAL CERTIFICATES FOR REINFORCING STEEL SIGNED BY THE MANUFACTURERAND CONTRACTOR.

- B. SUBMIT SHOP DRAWINGS FOR FABRICATION, BENDING AND PLACEMENT OF CONCRETE REINFORCEMENT INACCORDANCE WITH ACI 315 "DETAILS AND DETAILING OF CONCRETE REINFORCEMENT."

SU-5 CAST-IN-PLACE CONCRETE:

- A. SUBMIT MIX DESIGNS PREPARED, STAMPED AND SIGNED BY A PROFESSIONAL ENGINEER REGISTERED INTHE STATE OF CALIFORNIA FOR EACH CLASS OF CONCRETE. INCLUDE RESULTS OF SLUMP, SHRINKAGE ANDCOMPRESSION TESTS USED TO ESTABLISH MIX PROPORTIONS. ALSO INCLUDE CERTIFIED MATERIALCERTIFICATES FOR EACH COMPONENT OF THE MIX.

- B. SUBMIT PROPOSED CONSTRUCTION JOINT LOCATIONS FOR REVIEW.

- C. SUBMIT PRODUCT DATA FOR CURING MATERIALS.

- D. SUBMIT PRODUCT DATA FOR NON-SHRINK GROUT.

SU-6 STRUCTURAL STEEL:

- A. SUBMIT MILL CERTIFICATES FOR STRUCTURAL STEEL SHAPES INDICATING STRUCTURAL STRENGTH ANDCHEMICAL COMPOSITION FOR EACH HEAT OF STEEL

- B. SUBMIT SHOP DRAWINGS PRIOR TO FABRICATION. INCLUDE AT A MINIMUM ASTM MATERIAL DESIGNATIONS,MEMBER SIZES, SIZES AND TYPES OF WELDS, SIZES AND TYPES OF BOLTS AND DIMENSIONS.

- C. SUBMIT MILL CERTIFICATES FOR FASTENERS AND THREADED RODS.

- D. SUBMIT WELDING PROCEDURE SPECIFICATION FOR EACH TYPE OF WELD TO BE USED AND PRODUCT DATAFOR WELDING ELECTRODES.

- E. SUBMIT MANUFACTURERS PRODUCT DATA FOR PRIMER AND FINISH PAINT INCLUDING COLOR CHARTS.

SU-7 MECHANICAL ANCHORS: SUBMIT PRODUCT DATA FOR EACH TYPE OF ANCHOR USED.

SU-8 ADHESIVE ANCHORS: SUBMIT PRODUCT DATA FOR EACH TYPE OF ADHESIVE ANCHORING SYSTEM USED.

GR GENERAL REQUIREMENTS

GR-1 MATERIALS AND WORKMANSHIP TO CONFORM WITH THE 2016 EDITION OF THE CALIFORNIA BUILDING CODE,WITH CITY OF LOS ANGELES AMENDMENTS AND THE REQUIREMENTS OF THE CONTRACT DOCUMENTS.

GR-2 REFERENCE TO CODES, RULES, REGULATIONS, STANDARDS, MANUFACTURER'S INSTRUCTIONS ORREQUIREMENTS OF REGULATORY AGENCIES IS TO THE LATEST PRINTED EDITION OF EACH IN EFFECT AT THEDATE OF SUBMISSION OF BID UNLESS THE DOCUMENT DATE IS SHOWN.

GR-3 VERIFY ALL DIMENSIONS, ELEVATIONS, & SITE CONDITIONS BEFORE STARTING WORK. NOTIFY STRUCTURALENGINEER OF DISCREPANCIES.

GR-4 REFER TO ARCHITECTURAL & CIVIL DRAWINGS FOR EXTERIOR SLABS.

GR-5 DRAWINGS INDICATE GENERAL AND TYPICAL DETAILS OF CONSTRUCTION. WHERE CONDITIONS ARE NOTSPECIFICALLY INDICATED BUT ARE OF SIMILAR CHARACTER TO DETAILS SHOWN, USE SIMILAR DETAILS OFCONSTRUCTION, SUBJECT TO REVIEW BY THE OWNER'S REPRESENTATIVE.

GR-6 THE CONTRACTOR IS RESPONSIBLE FOR COORDINATING THE WORK OF ALL TRADES AND FOR CHECKINGDIMENSIONS. NOTIFY THE OWNER'S REPRESENTATIVE OF ANY DISCREPANCIES AND RESOLVE BEFOREPROCEEDING WITH THE WORK.

GR-7 DO NOT SCALE THE DRAWINGS.

GR-8 PROVIDE MEASURES NECESSARY TO PROTECT THE STRUCTURE DURING CONSTRUCTION. SUCH MEASURESINCLUDE, BUT MAY NOT BE LIMITED TO, BRACING AND SHORING FOR LOADS DURING CONSTRUCTION. RETAIN AREGISTERED CIVIL ENGINEER WHOM IS PROPERLY QUALIFIED TO DESIGN BRACING, SHORING, ETC. VISITS TOTHE SITE BY THE OWNER'S REPRESENTATIVE WILL NOT INCLUDE OBSERVATION OF THE ABOVE NOTED ITEMS.

GR-9 REFER TO ARCHITECTURAL DRAWINGS FOR SIZE AND LOCATION OF FLOOR, ROOF AND WALL OPENINGS NOTSHOWN ON THE STRUCTURAL DRAWINGS. COORDINATE THE SIZE AND LOCATION OF OPENINGS ASSOCIATEDWITH, BUT NOT LIMITED TO, ELECTRICAL, MECHANICAL AND PLUMBING TRADES. SUBMIT FINAL SIZING ANDLOCATION REQUIREMENTS OF OPENINGS TO THE OWNER'S REPRESENTATIVE FOR REVIEW.

GR-10 THE CONTRACTOR IS SOLELY RESPONSIBLE FOR PROVIDING A SAFE PLACE TO WORK AND MEETING THEREQUIREMENTS OF ALL APPLICABLE JURISDICTIONS. EXECUTE WORK TO ENSURE THE SAFETY OF PERSONSAND ADJACENT PROPERTY AGAINST DAMAGE BY FALLING DEBRIS AND OTHER HAZARDS IN CONNECTION WITHTHIS WORK.

FN FOUNDATION AND SITE WORK

FN-1 GROUNDWATER WAS NOT ENCOUNTERED DURING EXPLORATION AND IS NOT EXPECTED TO BE A FACTOR INDEVELOPMENT OF SITE.

FN-2 LOCATE AND PROTECT EXISTING UTILITIES TO REMAIN DURING AND/OR AFTER CONSTRUCTION.

FN-3 REMOVE ABANDONED FOOTINGS, UTILITIES, ETC. WHICH INTERFERE WITH NEW CONSTRUCTION, UNLESSOTHERWISE INDICATED.

FN-4 NOTIFY THE OWNER'S REPRESENTATIVE IF ANY BURIED STRUCTURES NOT INDICATED, SUCH AS CESSPOOLS,CISTERNS, FOUNDATIONS, ETC., ARE FOUND.

FN-5 THE CONTRACTOR IS SOLELY RESPONSIBLE FOR EXCAVATION PROCEDURES INCLUDING LAGGING, SHORING,UNDERPINNING AND PROTECTION OF EXISTING CONSTRUCTION.

FN-6 REMOVE LOOSE SOIL AND STANDING WATER FROM FOUNDATION EXCAVATIONS PRIOR TO PLACING CONCRETE.

FN-7 EXCAVATIONS FOR FOUNDATIONS MUST BE ACCEPTED BY THE GEOTECHNICAL ENGINEER PRIOR TO PLACINGREINFORCING AND CONCRETE. NOTIFY THE GEOTECHNICAL ENGINEER WHEN EXCAVATIONS ARE READY FORINSPECTION.

FN-8 PLACE BACKFILL BEHIND RETAINING WALLS AFTER CONCRETE OR MASONRY HAS ATTAINED FULL DESIGNSTRENGTH. BRACE BUILDING AND PIT WALLS BELOW GRADE FROM LATERAL LOADS UNTIL ATTACHED FLOORSAND SLABS ON GRADE ARE COMPLETE AND HAVE ATTAINED FULL DESIGN STRENGTH.

FN-9 COMPACT EXCAVATION BACKFILLS IN LAYERS PER THE GEOTECHNICAL REPORT. FIELD OBSERVATION ANDTESTING SHALL BE PERFORMED BY THE SOILS ENGINEER DURING GRADING TO ASSIST THE CONTRACTOR INOBTAINING THE REQUIRED DEGREE OF COMPACTION AND PROPER MOISTURE CONTENT.

FN-10 IF ADVERSE SOIL CONDITIONS ARE ENCOUNTERED, NOTIFY GEOTECHNICAL ENGINEER AND ADDITIONAL SOILSREPORT MAY BE REQUIRED.

STRUCTURAL DRAWING LIST

Sheet Number Sheet Name

000 GENERAL NOTES - BASE

_SH0.00* SHORING GENEREAL NOTES BASE

NE_REFERENCE

SS2.2 TYPICAL FRAMING PLAN

SS2.3 TYPICAL SHEAR WALL & POST PLAN

S0 SERIES: SHEET LIST, GENERAL NOTES, TYPICAL DETAILS

S0.00 GENERAL NOTES, ABBREVIATIONS, & SHEET LIST

S0.01 GENERAL NOTES

S0.10 TYPICAL CONCRETE DETAILS - REBAR

S0.11 TYPICAL CONCRETE DETAILS - FOUNDATIONS & SLAB ON GRADE

S0.12 TYPICAL CONCRETE DETAILS - ELEVATED SLAB REINFORCING

S0.13 TYPICAL CONCRETE DETAILS - WALL REINFORCING & COLUMNS

S0.30 TYPICAL WOOD DETAILS - GENERAL FRAMING & STUD WALLS

S0.31 TYPICAL WOOD DETAILS - SHEAR WALLS

S0.32 TYPICAL WOOD DETAILS - HORIZONTAL DIAPHRAGMS

S1 SERIES: RETAINING WALL PLAN

S1.00 RETAINING WALL PLAN

S2 SERIES: FOUNDATION PLAN, FRAMING PLAN, AND SLAB REINFORCING PLANS

S2.00 BASEMENT FOUNDATION PLAN

S2.01 MAIN LEVEL FRAMING PLAN

S2.01R MAIN LEVEL REINFORCEMENT PLAN

S2.02 UPPER LEVEL FRAMING PLAN

S2.02R UPPER LEVEL REINFORCEMENT PLAN

S2.03 ROOF FRAMING PLAN

S3 SERIES: LATERAL FRAME ELEVATIONS AND BUILDING SECTIONS

S3.00 BUILDING SECTIONS

S3.01 BUILDING SECTIONS

S3.02 BUILDING SECTIONS

S3.10 STAIR PLANS AND DETAILS

S4 SERIES: POOL SUPPORT

S4.00 POOL PLANS AND SECTIONS

S5 SERIES: PROJECT SPECIFIC DETAILS

S5.00 PROJECT SPECIFIC DETAILS

SH SERIES: SHORING NOTES, DETAILS, PLANS

SH0.00 SHORING GENERAL NOTES

SH0.10 TYPICAL SHORING DETAILS

SH1.00 SHORING PLAN

IO STRUCTURAL TEST AND INSPECTIONS

IO-1 AN INDEPENDENT TESTING AGENCY AND SPECIAL INSPECTORS WILL BE RETAINED BY THE OWNER TOPERFORM THE FOLLOWING TESTS AND INSPECTION. PROVIDE ACCESS AND FURNISH SAMPLES TO THEAGENCY AS REQUIRED BY THE CONTRACT DOCUMENTS.

IO-2 CONTRACTORS RESPONSIBLE FOR THE CONSTRUCTION OF A WIND OR SEISMIC FORCE RESISTING SYSTEM/COMPONENT AS LISTED IN THE "STATEMENT OF SPECIAL INSPECTION" SHALL SUBMIT A WRITTEN STATEMENTOF RESPONSIBILITY TO THE LADBS INSPECTORS AND THE OWNER PRIOR TO THE COMMENCEMENT OF WORKON SUCH A SYSTEM OR COMPONENT PER 1704.4.

IO-3 IF INITIAL TESTS OR INSPECTIONS MADE BY THE OWNER'S TESTING AGENCY REVEAL THAT ANY PORTION OFTHE WORK DOES NOT COMPLY WITH THE CONTRACT DOCUMENTS, ADDITIONAL TESTS, INSPECTIONS, ANDNECESSARY REPAIRS WILL BE MADE AT THE CONTRACTOR'S EXPENSE.

IO-4 THE FOLLOWING ITEMS REQUIRE TESTS AND INSPECTIONS IN ACCORDANCE WITH THE REQUIREMENTS OF THECHAPTER "STRUCTURAL TEST AND INSPECTIONS" OF THE CODE OF THE GOVERNING JURISDICTION AS NOTEDIN THE GENERAL SECTION OF THESE GENERAL NOTES. AN "X" PRESENT IN COLUMN "C" INDICATES CONTINUOUSINSPECTION & "X" PRESENT IN COLUMN "P" INDICATES PERIODIC INSPECTION.

CAST IN PLACE DEEP FOUNDATIONS

VERIFICATION AND INSPECTION C P

1. 1.OBSERVE DRILLING OPERATIONS AND MAINTAIN COMPLETE AND ACCURATERECORDS FOR EACH ELEMENT.

X -

2. VERIFY PLACEMENT LOCATIONS AND PLUMBNESS, CONFIRM ELEMENT DIAMETERS,BELL DIAMETERS (IF APPLICABLE), LENGTHS, EMBEDMENT INTO BEDROCK (IFAPPLICABLE) AND ADEQUATE END BEARING STRATA CAPACITY, RECORD CONCRETEOR GROUT VOLUMES.

X -

3. FOR CONCRETE ELEMENTS, PERFORM ADDITIONAL INSPECTIONS IN ACCORDANCEWITH SECTION 1704.4.

- -

CONCRETE

VERIFICATION AND INSPECTION C P

1. INSPECTION OF REINFORCING STEEL, PRESTRESSING TENDONS, AND PLACEMENTS. - X

2. INSPECTION OF REINFORCING STEEL WELDING IN ACCORDANCE WITH TABLE 1704.3ITEM 5B OF IBC/CBC.

- -

3. INSPECTION OF BOLTS TO BE INSTALLED IN CONCRETE PRIOR TO AND DURINGPLACEMENT OF CONCRETE WHERE ALLOWABLE LOADS HAVE BEEN INCREASED ORWHERE STRENGTH DESIGN IS USED.

X -

4. INSPECTION OF ANCHORS INSTALLED IN HARDENED CONCRETE. (i.e. POST INSTALLEDANCHORS).

- X

5. VERIFYING USE OF REQUIRED DESIGN MIX. - X

6. AT THE TIME FRESH CONCRETE IS SAMPLED TO FABRICATE SPECIMENS FORSTRENGTH TESTS, PERFORM SLUMP AND AIR CONTENT TESTS AND DETERMINE THETEMPERATURE OF THE CONCRETE.

X -

7. INSPECTION OF CONCRETE AND SHOTCRETE PLACEMENT FOR PROPER APPLICATIONTECHNIQUES.

X -

8. INSPECTION FOR MAINTENANCE OF SPECIFIED CURING TEMPERATURE ANDTECHNIQUES.

- X

ROUGH CARPENTRY

VERIFICATION AND INSPECTION C P

1. SHEARWALL HOLDOWNS AND SILL ANCHORS. - X

2. SHEARWALL NAILING WITH NAIL SPACING LESS THAN 4" OC. - X

3. DIAPHRAGM NAILING WITH NAIL SPACING LESS THAN 4" OC. - X

4. STRAPS AT DIAPHRAGM INSTALLATION. - X

SOILS

VERIFICATION AND INSPECTION C P

1. VERIFY MATERIALS BELOW SHALLOW FOUNDATION ARE ADEQUATE TO ACHIEVE THEDESIGN BEARING CAPACITY.

- X

2. VERIFY EXCAVATIONS ARE EXTENDED TO PROPER DEPTH AND HAVE REACHEDPROPER MATERIAL.

- X

3. PERFORM CLASSIFICATION AND TESTING OF COMPACTED FILL MATERIALS. - X

4. VERIFY USE OF PROPER MATERIALS, DENSITIES AND LIFT THICKNESSES DURINGPLACEMENT AND COMPACTION OF COMPACTED FILL.

X -

5. PRIOR TO PLACEMENT OF COMPACTED FILL, OBSERVE SUBGRADE AND VERIFY THATSITE HAS BEEN PREPARED PROPERLY.

- X

STRUCTURAL STEEL

VERIFICATION AND INSPECTION C P

1. MATERIAL VERIFICATION OF HIGH-STRENGTH BOLTS, NUTS, AND WASHERS:

a. MANUFACTURER'S CERTIFICATE OF COMPLIANCE REQUIRED. - X

b. IDENTIFICATION MARKINGS TO CONFORM TO ASTM STANDARDS SPECIFIED IN THEAPPROVED CONSTRUCTION DOCUMENTS.

- X

2. INSPECTION OF HIGH-STRENGTH BOLTING:

a. SNUG-TIGHT JOINTS. - X

b. PRETENSIONED AND SLIP-CRITICAL JOINTS USING TURN-OF-NUT WITH MATCHMAKING,TWIST-OFF BOLT OR DIRECT TENSION INDICATOR METHODS OF INSTALLATION.

- X

c. PRETENSIONED AND SLIP-CRITICAL JOINTS USING TURN-OF-NUT WITHOUTMATCHMAKING OR CALIBRATED WRENCH METHODS OF INSTALLATION.

X -

3. MATERIAL VERIFICATION OF STRUCTURAL STEEL:

a. FOR STRUCTURAL STEEL IDENTIFICATION MARKINGS TO CONFORM TO AISC 360. - X

b. FOR OTHER STEEL, IDENTIFICATION MARKINGS CONFORM TO ASTM STANDARDSSPECIFIED IN THE APPROVED CONSTRUCTION DOCUMENTS.

- X

c. MANUFACTURER'S CERTIFIED TESTS REPORT. - X

4. MATERIAL VERIFICATION OF WELD FILLER MATERIALS:

a. IDENTIFICATION MARKINGS TO CONFORM TO AWS SPECIFICATION IN THE APPROVEDCONSTRUCTION DOCUMENTS.

- X

b. MANUFACTURER'S CERTIFICATE OF COMPLIANCE REQUIRED. - X

5. a INSPECTION OF WELDING - STRUCTURAL STEEL:

1. COMPLETE AND PARTIAL JOINT PENETRATION GROOVE WELDS. X -

2. MULTIPASS FILLET WELDS. X -

3. SINGLE-PASS FILLET WELDS > 5/16". X -

4. PLUG AND SLOT WELDS. X -

5. SINGLE-PASS FILLET WELDS < 5/16". - X

6. FLOOR AND ROOF DECK WELDS. - X

SO STRUCTURAL OBSERVATIONS

SO-1 NOTIFY THE ENGINEER AT SIGNIFICANT CONSTRUCTION STAGES 72 HOURS IN ADVANCE AND PROVIDE ACCESSFOR THE FOLLOWING STRUCTURAL OBSERVATIONS:

- A. FOUNDATIONS

1. REINFORCEMENT

- B. STEEL FRAMING

1. GENERAL

- C. WOOD FRAMING

1. GENERAL

2. SHEAR WALLS AND HOLD-DOWNS

3. DIAPHRAGMS AND COLLECTORS

- D. CONCRETE

1. WALL REINFORCEMENT

2. SLABS AND SLABS-ON-GRADE

A COPY OF THE LARR AND/OR CONDITIONS OF LISTING SHALL BE MADE AVAILABLE AT THE JOB SITE.

1901

11 S

UD ­

STRU

CTUR

AL P

ROGR

ESS

Page 2: GENERAL NOTES, ABBREVIATIONS, & SHEET LIST · 2019-07-15 · dc -6 wind design: dc dc -1 design criteria dc -2 dc -3 live loads ... scbf special concentrically braced frame sched

TH

OM

AS

CA

LU

S

16

20

SU

MM

ITR

IDG

E D

RIV

E,

BE

VE

RL

Y H

ILL

S, C

A 9

02

10

SU

D

da

tesh

ee

t title

sh

ee

t nu

mb

er

revis

ion

sclie

nt

dra

wn b

y

da

te

f:e

:31

0. 4

24.5

230

p:31

0.92

9.78

15in

fo@

dom

aen.

net

915

mat

eo s

treet

suite

205

los

ange

les

ca

9002

1

ww

w.d

omae

n.ne

t

EXP 03/31/2019C80463

STATE OF CALIFORN IA

ELIZ

ABE H MAHLOW

REG

IST

ERED

PROFESS IONA L ENGIN

EER

C I V IL

T

600

WIL

SH

IRE

BLV

D, S

UIT

E 7

60LO

S A

NG

ELE

S, C

A 9

0017

213

627

6687

CO

NTA

CT

@N

OU

SE

NG

INE

ER

ING

.CO

M

NOT FOR CONSTRUCTION

GE

NE

RA

L N

OT

ES

S0.

01

Aut

hor

01/0

4/1

9

DP DRILLED PIERS

DP-1 DESIGN AND PROVIDE A FULL-LENGTH WATERTIGHT TEMPORARY STEEL CASING, AS REQUIRED, TO MAINTAINSHAFT WALLS WITHOUT DISPLACING AND TO WITHSTAND COMBINED COMPRESSIVE AND WITHDRAWALSTRESSES. WITHDRAW CASING AS CONCRETE IS PLACED MAINTAINING A HEAD OF CONCRETE BETWEEN 5 AND 10FEET ABOVE THE CASING BOTTOM.

DP-2 EACH DRILLED PIER MUST BE INSPECTED BY THE GEOTECHNICAL ENGINEER PRIOR TO PLACING CONCRETE ANDREINFORCING STEEL. ADJUST SHAFT LENGTHS UNDER DIRECTION OF THE GEOTECHNICAL ENGINEER AND THEOWNER'S REPRESENTATIVE BASED ON SOIL CONDITIONS OBSERVED AT TIME OF DRILLING.

DP-3 PLACE REINFORCING STEEL IN ONE CONTINUOUS UNIT AND ACCURATELY HOLD SECURELY IN FINAL POSITIONUSING CHAIRS OR SPACERS DURING CONCRETE PLACEMENT.

DP-4 KEEP EXCAVATIONS FREE OF WATER BEFORE PLACING CONCRETE UNLESS OTHERWISE APPROVED BY THEGEOTECHNICAL ENGINEER. IF UNABLE TO SEAL OFF WATER FLOW AND APPROVED BY THE GEOTECHNICALENGINEER, ALLOW WATER LEVEL TO ATTAIN ITS NORMAL LEVEL AND PLACE CONCRETE BY THE TREMIE METHODOR OTHER APPROVED METHOD.

DP-5 USE AN ELEPHANT TRUNK, TREMIE PIPE, OR OTHER APPROVED METHOD TO PLACE CONCRETE IN A CONTINUOUSAND SMOOTH FLOW WITHOUT SEGREGATING THE CONCRETE. DO NOT ALLOW CONCRETE TO FREE FALL MORETHAN 5 FEET.

DP-6 MECHANICALLY VIBRATE AT LEAST THE TOP 25 FEET OF CONCRETE AT EACH PIER.

DP-7 WHEN THE TREMIE METHOD IS ALLOWED, MAINTAIN AT LEAST 5 FEET OF CONCRETE HEAD ABOVE THE END OFTHE TREMIE PIPE DURING THE ENTIRE CONCRETE PLACING OPERATION.

CC CAST IN PLACE CONCRETE

CC-1 PROPORTION, MIX, TRANSPORT, AND PLACE CAST-IN-PLACE CONCRETE IN ACCORDANCE WITH ACI 301"SPECIFICATIONS FOR STRUCTURAL CONCRETE," UON.

CC-2 CONCRETE IS REINFORCED AND CAST-IN-PLACE UNLESS OTHERWISE NOTED. WHERE REINFORCING IS NOTSPECIFICALLY SHOWN OR WHERE DETAILS ARE NOT GIVEN, PROVIDE REINFORCING SIMILAR TO THAT SHOWNFOR SIMILAR CONDITIONS, SUBJECT TO REVIEW BY THE OWNER'S REPRESENTATIVE.

CC-3 ROUGHEN CONCRETE SURFACES OF CONSTRUCTION JOINTS TO 1/4 INCH AMPLITUDE AND CLEAN OF LAITANCE,FOREIGN MATTER, AND LOOSE PARTICLES. LOCATE CONSTRUCTION JOINTS AS SHOWN ON THE DRAWINGS.SUBMIT ALTERNATE JOINT LOCATIONS OR JOINTS NOT SHOWN TO THE OWNER'S REPRESENTATIVE FOR REVIEWAND APPROVAL PRIOR TO PROCEEDING WITH THE WORK.

CC-4 AT LOCATIONS WHERE CONCRETE IS CAST AGAINST EXISTING CONCRETE, ROUGHEN CONTACT SURFACES TO 1/4INCH AMPLITUDE AND CLEAN OF LAITANCE, FOREIGN MATTER, AND LOOSE PARTICLES.

CC-5 AT LOCATIONS WHERE CONCRETE IS CAST AGAINST EXISTING MASONRY, THOROUGHLY ROUGHEN CONTACTSURFACES BY LIGHT SANDBLASTING OR OTHER SUITABLE MEANS AND CLEAN OF LAITANCE, FOREIGN MATTER,AND LOOSE PARTICLES.

CC-6 REFER TO ARCHITECTURAL AND MECHANICAL DRAWINGS FOR LOCATIONS OF ADDITIONAL CONCRETE CURBSAND HOUSEKEEPING PADS NOT SHOWN.

CC-7 CONTINUOUSLY MOIST CURE CONCRETE SLABS-ON-GRADE FOR 7 DAYS MINIMUM. WATER FOG SPRAYS,PONDING, SATURATED ABSORPTIVE COVERS, OR MOISTURE RETAINING COVERS MAY BE USED. CURINGCOMPOUNDS CAN BE USED BASED ON SATISFACTORY PERFORMANCE ON PREVIOUS APPLICATIONS.CONTRACTOR TO SUBMIT SPECIFICATIONS FOR REVIEW AND APPROVAL.

CC-8 NON-SHRINK GROUT: NON-METALLIC AGGREGATE TYPE, COMPLYING WITH ASTM C1107 AND CAPABLE OFDEVELOPING A MINIMUM COMPRESSIVE STRENGTH OF 7,000 PSI AT 28 DAYS.

CC-9 CONCRETE TYPES:

CC-10 CONCRETE CLEAR COVER TO REINFORCING BARS IS AS FOLLOWS:

LOCATION CLEAR COVER

CONCRETE CAST AGAINST AND PERMANENTLYEXPOSED TO EARTH

- ALL BARS 3"

CONCRETE EXPOSED TO EARTH OR WEATHER:

- #6 THROUGH #18 BARS 2"

- #5 BAR, W31 OR D31 WIRE, AND SMALLER 1 1/2"

CONCRETE NOT EXPOSED TO EARTH OR WEATHER:

- SLABS, WALLS, JOISTS: #14 AND #18 BARS 1 1/2"

- SLABS, WALLS, JOISTS: #11 AND SMALLER 3/4"

- BEAMS, COLUMNS: PRIMARY REINFORCEMENT, TIES, STIRRUPS, SPIRALS ANDHOOPS

1 1/2"

CLASS LOCATION 28 DAY f'c TYPEW/C

RATIO

MAX AGGREGATE

SIZE

A DEEP FOUNDATIONS, WALLS 3000 PSI NORMAL WEIGHT

B SHALLOW FOUNDATIONS, MISCCURBS, PADS, ETC. SLABS ONGRADE

2500 PSI NORMAL WEIGHT

C SUSPENDED SLABS 5000 PSI NORMAL WEIGHT

RE REINFORCING STEEL

RE-1 FABRICATE AND PLACE REINFORCING STEEL IN ACCORDANCE WITH ACI 315 "DETAILS AND DETAILING CONCRETEREINFORCING" AND ACI 301 "SPECIFICATIONS FOR STRUCTURAL CONCRETE," UON.

RE-2 ACCURATELY POSITION, SUPPORT, AND SECURE REINFORCEMENT FROM DISPLACING DUE TO FORMWORK,CONSTRUCTION, OR CONCRETE PLACEMENT OPERATIONS. LOCATE AND SUPPORT REINFORCING BY METALCHAIRS, RUNNERS, BOLSTERS, SPACERS, AND HANGERS AT A MAXIMUM 3-FOOT SPACING.

RE-3 MECHANICAL COUPLERS: LENTON THREADED OR INTERLOCK COUPLERS BY ERICO (IAPMO UES ER-0129 & LARR24507), OR EXTENDER BY HEADED REINFORCEMENT CORPORATION (ICC ESR-2764 & LARR 25347). COUPLERS FORBEAM AND SLAB BARS AT FORMED CONSTRUCTION JOINTS MAY BE LENTON FORM SAVERS BY ERICO (IAPMOER-0188 & LARR 25893).

RE-4 WELD REINFORCING STEEL IN ACCORDANCE WITH AWS D1.4 USING QUALIFIED WELDERS.

RE-5 TERMINATE REINFORCING STEEL IN STD HOOKS, UNLESS OTHERWISE SHOWN.

RE-6 PROVIDE REINFORCING SHOWN OR NOTED CONTINUOUS IN LENGTHS AS LONG AS PRACTICABLE.

RE-7 REINFORCING STEEL #8 AND LARGER AND ALL REINFORCING STEEL TO BE WELDED TO BE ASTM A706, 60KSI. ALLOTHER REINFORCING STEEL TO BE ASTM A615, 60KSI.

RE-8 SMOOTH DOWELS IN SLAB ON GRADE TO BE ASTM A36, 36KSI.

FW FORMWORK

FW-1 DESIGN AND CONSTRUCT FORMWORK IN ACCORDANCE WITH ACI 347 "RECOMMENDED PRACTICE FORCONCRETE FORMWORK" AND ACI 301 "SPECIFICATIONS FOR STRUCTURAL CONCRETE," UON.

FW-2 REMOVE FORMS AND SHORES IN ACCORDANCE WITH THE FOLLOWING:

A. 48 HOURS: FORMS FOR FOOTINGS, PILE CAPS, AND GRADE BEAMS

B. 72 HOURS: FORMS FOR COLUMNS, WALLS, AND SIDE FORMS FOR BEAMS AND GIRDERS

C. 7 DAYS, AND f'c=3,500 PSI MIN: BOTTOM FORMS AND SHORES FOR MILDLY REINFORCED SLABS, BEAMS, ANDGIRDERS

FW-3 PROVIDE POUR POCKETS IN FORMS AND UNDER EXISTING STRUCTURAL MEMBERS AS REQUIRED TO PREVENTAIR POCKETS AND/OR "HONEYCOMB" UNDER OR AROUND THE EXISTING MEMBERS. CONCRETE CAST WITH AIRPOCKETS AND/OR "HONEYCOMB" UNDER OR AROUND THE MEMBERS IS NOT ACCEPTABLE.

FW-4 PROVIDE 3/4 INCH x 3/4 INCH CHAMFER STRIPS ON ALL EXTERNAL CORNERS OF BEAMS, COLUMNS, AND WALLS,UON.

FW-5 PROVIDE CURING WHERE FORMS ARE REMOVED IN LESS THAN 7 DAYS, INCLUDING BUT NOT LIMITED TO WALLS,COLUMNS, AND UNDERSIDE OF ELEVATED SLABS.

SS STRUCTURAL STEEL

SS-1 AISC CERTIFIED FABRICATOR OR LADBS LICENSED FABRICATOR IS REQUIRED FOR ALL STRUCTURAL STEEL.

SS-2 FABRICATE AND ERECT STRUCTURAL STEEL IN ACCORDANCE WITH AISC "SPECIFICATION FOR DESIGN,FABRICATION AND ERECTION OF STRUCTURAL STEEL FOR BUILDINGS." WELDED CONNECTIONS TO CONFORM TOAWS D1.1.

SS-3 HOT DIP GALVANIZE IN ACCORDANCE WITH ASTM A123 AND ASTM A153 STRUCTURAL STEEL AND FASTENERSTHAT ARE PERMANENTLY EXPOSED TO THE WEATHER. REPAIR GALVANIZING AFTER WELDING IN ACCORDANCEWITH ASTM A780.

SS-4 ARC-WELDING ELECTRODE / FILLER METALS TO BE LOW HYDROGEN TYPES E7XTX, E7XTXX OR E70XXX MINIMUMAS APPLICABLE. DEMAND CRITICAL WELDS, WHERE NOTED AS "DC", SHALL BE MADE WITH A FILLER METALCAPABLE OF PROVIDING A MINIMUM CHARPY V-NOTCH (CVN) TOUGHNESS OF 20 FT-LB (27J) AT -20°F (-29°C), ASDETERMINED BY THE APPROPRIATE AWS CLASSIFICATION TEST METHOD, AND 40 FT-LB (54J) AT 70°F (21°C),WHEN THE STEEL FRAME IS NORMALLY ENCLOSED AND MAINTAINED AT A TEMPERATURE OF 50°F (10°C) ORHIGHER.

SS-5 WELDERS TO BE CERTIFIED BY AWS . ALL SHOP WELDS MUST BE PERFORMED IN AN AWS CERTIFIED OR LADBSLICENSED FABRICATORS SHOP.

SS-6 WHERE FIELD WELDING IS NOTED, THE DESIGNATION IS GIVEN AS A SUGGESTED CONSTRUCTION PROCEDUREONLY.

SS-7 FIELD WELDING TO BE DONE BY WELDERS CERTIFIED BY AWS OR THE LADBS FOR STRUCTURAL STEEL.CONTINUOUS SPECIAL INSPECTION BY DEPUTY INSPECTOR IS REQUIRED.

SS-8 PROVIDE NATURAL CAMBER UP, UNLESS OTHERWISE NOTED, EXCEPT AT CANTILEVERS. AT CANTILEVERSPROVIDE CAMBER SUCH THAT TIP OF CANTILEVER IS ABOVE FINAL ELEVATION.

SS-9 SPLICE MEMBERS ONLY WHERE INDICATED.

SS-10 STRUCTURAL STEEL TO CONFORM TO THE FOLLOWING UNLESS OTHERWISE NOTED:

SECTION MATERIAL TYPE

ROLLED SHAPES

WIDE FLANGES AND WT ASTM A992, GR50

CHANNELS, ANGLES & OTHER ASTM A36

PLATES

COLUMN BASE PLATES ASTM A572, GR 50

BRACE GUSSET PLATES ASTM A572, GR 50

BEAM COVER/SIDE PLATES ASTM A36

COLUMN CONTINUITY PLATES ASTM A572, GR 50

BEAM STIFFENER PLATES ASTM A36

DECK CLOSURE PLATES ASTM A36

OTHER, OUN ASTM A572, GR 50

OTHER TYPES

STEEL PIPE ASTM A53, GRADE B

HOLLOW STRUCTURAL SECTION (HSS) ASTM A500, GRADE B

STAINLESS STEEL SHAPES, PLATES AND BARS ASTM A276

BOLTS ASTM A325X

MACHINE BOLTS ASTM A307

ANCHOR BOLTS / ANCHOR RODS ASTM F1554, GR 36

THREADED AND HANGER ROD ASTM A36

WELDED SHEAR CONNECTORS ASTM A108 GRADE 1015 THROUGH 1020

NUTS FOR BOLTS AND MACHINE BOLTS ASTM A563

HARDENED WASHERS ASTM F436

UNHARDENED WASHERS ASTM F844

PLAIN WASHERS ANSI B18.22.1

BEVELED WASHERS ANSI B18.23.1

RC ROUGH CARPENTRY

RC-1 FRAMING LUMBER: DOUGLAS FIR (COAST REGION) GRADED AND MARKED IN ACCORDANCE WITH THE STDGRADING RULES NO. 17 OF THE WEST COAST LUMBER INSPECTION BUREAU (WCLIB) OR WESTERN LUMBERGRADING RULES, OF THE WESTERN WOOD PRODUCTS ASSOCIATION (WWPA). USE LUMBER OF THE FOLLOWINGGRADES:

- A. SILLS: STUD GRADE PRESSURE OR PRESERVATIVE TREATED, NATURALLY DURABLE, OR FOUNDATION GRADEREDWOOD; 19% MOISTURE CONTENT, UON.

- B. STUDS: STUD GRADE; 19% MOISTURE CONTENT, UON.

- C. JOISTS, PLANKS AND PLATES: DF #2; 15% MOISTURE CONTENT, UON.

- D. BEAMS, DF #2; 19% MOISTURE CONTENT, UON.

- E. POSTS, DF #1; 19% MOISTURE CONTENT, UON.

- F. FRAMING, BLOCKING AND BRIDGING: STUD GRADE; 15% MOISTURE CONTENT, UON.

- G. PLYWOOD BLOCKING: DF #2; 19% MOISTURE CONTENT.

- H. BACKING: PER CONSTRUCTION; 19% MOISTURE CONTENT

RC-2 MANUFACTURED LUMBER:

- A. LVL: MICROLAM LVL 1.9E, ICC ESR-1387 & LARR 25202.

- B. PSL: PARALLAM PSL 2.0E, ICC ESR-1387 & LARR 25202.

RC-3 PANEL SHEATHING: IDENTIFY WOOD STRUCTURAL PANELS WITH THE APPROPRIATE TRADEMARK OF APA-THEENGINEERED WOOD ASSOCIATION AND MEET THE REQUIREMENTS OF THE VOLUNTARY PRODUCT STD PS-1 ORPS-2 AND APA PRP-108 PERFORMANCE STD.

- A. PANEL SHEATHING TO BE EXPOSURE 1.

- B. PLYWOOD PANELS TO BE 5-PLY MINIMUM, EXCEPT 3/8" PANELS TO BE 3-PLY MINIMUM.

- C. OSB PANELS MAY BE USED WITH APPROVAL OF SEOR.

- D. PLYWOOD TO BE C-C GRADE AT LOCATIONS EXPOSED TO WEATHER; CD GRADE ELSEWHERE.

- E. SHEATH ALL EXTERIOR WALLS WITH 15/32" PLYWOOD WITH 10d NAILS WITH (6",6",12") OC, (BN, EN, FN UON).

- F. PROVIDE THE FOLLOWING GRADE AND SPAN RATINGS:

RC-4 ROUGH HARDWARE:

- A. NAILS: COMMON WIRE NAILS, FEDERAL SPECIFICATION FF-N-105B, STANDARD LENGTHS UON USEHOT-DIPPED ZINC-COATED GALVANIZED NAILS FOR EXTERIOR INSTALLATIONS AND WHEN PENETRATINGPRESSURE TREATED OR FIRE-RETARDANT LUMBER.

- B. BOLTS AND THREADED RODS: ASTM A307, SQ OR HEXAGONAL HEAD MACHINE BOLTS WITH ASTM A563 NUTS.USE MALLEABLE IRON WASHERS UNDER HEAD AND NUT WHEN IN CONTACT WITH WOOD. AT SILL PLATES USE2"x2"x3/16" MINIMUM PLATE WASHERS.

- C. LAG SCREWS: ASTM A307, ANSI/ASME STANDARD B18.2.1. USE ANSI B18.22.1 WASHERS UNDER HEAD WHENIN CONTACT WITH WOOD.

- D. SCREWS: ASTM A307, ANSI/ASME STANDARD B18.6.1. USE CADMIUM-PLATED PAN OR ROUND HEADEDSCREWS AT STEEL TO WOOD AND WOOD TO WOOD CONNECTIONS.

- E. BOLTS, NUTS, WASHERS, STRAPS AND OTHER HARDWARE EXPOSED TO THE WEATHER TO BE HOT-DIPPEDGALVANIZED OR STAINLESS STEEL.

- F. FRAMING CLIPS, SHEET METAL STRAPS, ETC.: SIMPSON, UNIVERSAL, OR EQUIVALENT, WITH LARR REPORTS.DESIGNATIONS ON DRAWINGS ARE BASED ON SIMPSON CATALOGUE NUMBERS (IAPMO UES ER 112 & LARR25814). PROVIDE THE TYPE OF NAILS SPECIFIED BY THE MANUFACTURER AND FULLY DRIVE NAILS INTO ALLHOLES OF THE CONNECTOR UNLESS NOTED OTHERWISE ON THE PLANS. ALL CONNECTORS SHALL BEGALVANIZED OR HAVE ANOTHER FACTORY APPLIED FINISH. ALL STEEL FRAMING HANGERS TO BE TORSIONALRESTRAINT. SOLID BLOCKING REQUIRED BETWEEN JOISTS WHERE TORSIONAL RESTRAINT HANGERS DO NOTOCCUR.

RC-5 BOLT AND SCREW INSTALLATION

- A. DRILL BOLT HOLES 1/32 TO 1/16 (MAX) INCH LARGER IN DIA THAN THE BOLT NOMINAL DIA.

- B. DRILL PRE-BORED LEAD HOLES FOR WOOD SCREWS AS FOLLOWS.

1. PROVIDE LEAD HOLE 40% - 70% OF THREADED SHANK DIA AND FULL DIA FOR SMOOTH SHANK PORTION.

2. DRILL LEAD HOLE FOR THE SHANK TO A DEPTH EQUAL TO THE LENGTH OF THE UNTHREADED PORTION INTHE MAIN MEMBER. USE A DRILL BIT 7/8 THE DIA OF THE WOOD SCREW.

3. EXTEND THE LEAD HOLE FOR THE THREADED PORTION OF THE SCREW WITH A DRILL BIT WHOSE DIA IS40%-70% THE DIA OF THE SCREW AT THE ROOT OF THE THREAD.

4. INSERT THE SCREW INTO LEAD HOLE BY TURNING. DO NOT DRIVE WITH A HAMMER.

5. LUBRICATE WITH SOAP OR BEESWAX TO FACILITATE INSTALLATION.

- C. DRILL PRE-BORED LEAD HOLES FOR LAG SCREWS AS FOLLOWS.

1. PROVIDE LEAD HOLE 40% - 70% OF THREADED SHANK DIA AND FULL DIA FOR SMOOTH SHANK PORTION.

2. DRILL LEAD HOLE FOR THE SHANK TO A DEPTH EQUAL TO THE LENGTH OF THE UNTHREADED PORTION INTHE MAIN MEMBER. USE A DRILL BIT OF THE SAME DIA AS THE LAG SCREW.

3. EXTEND THE LEAD HOLE FOR THE THREADED PORTION OF THE LAG SCREW WITH A DRILL BIT WHOSE DIA IS60 PERCENT OF THE NOMINAL LAG SCREW DIA.

4. INSERT LAG SCREW INTO LEAD HOLE BY TURNING. DO NOT DRIVE WITH A HAMMER.

5. LUBRICATE WITH SOAP OR BEESWAX TO FACILITATE INSTALLATION.

RC-6 HOLD DOWN CONNECTOR BOLTS INTO WOOD FRAMING REQUIRE APPROVED PLATE WASHERS; AND HOLD DOWNSSHALL BE FINGER TIGHT AND 1/2 WRENCH TURNED JUST PRIOR TO COVERING WALL FRAMING. CONNECTORBOLTS INTO WOOD FRAMING REQUIRE STEEL PLATE WASHERS ON THE POST ON THE OPPOSITE SIDE OFANCHORAGE DEVICE. PLATE SHALL BE 0.299x3x3 IN MIN.

RC-7 HOLD-DOWN HARDWARE MUST BE SECURED IN PLACE PRIOR TO FOUNDATION INSPECTION.

RC-8 INSTALL SOLID BLOCKING BETWEEN JOISTS AT ENDS AND OVER SUPPORTS. PROVIDE 2 INCH BY 3 INCH CROSSBRIDGING, METAL BRIDGING, OR SOLID BLOCKING BETWEEN JOISTS IN SPANS EQUALLY SPACED 8 FEET OCMAXIMUM AND WHERE INDICATED.

RC-9 DO NOT USE WOOD SHINGLE SHIMS UNDER STUDS, JOISTS, BEAMS, OR POSTS.

RC-10 NAILING:

- A. DRIVE NAILS PERPENDICULAR TO THE GRAIN, UON

- B. PREDRILLED HOLES TO 3/4 OF NAIL DIA WHERE SPECIFIED AND WHEN WOOD TENDS TO SPLIT.

- C. AIR-DRIVEN NAILS TO BE FULL-HEADED NAILS. DO NOT OVERDRIVE NAILS.

- D. PANEL SHEATHING

1. AT DIAPHRAGM SHEATHING, USE RING SHANK NAILS. USE SMOOTH SHANK NAILS AT WALLS.

2. USE OF MACHINE NAILING IS SUBJECT TO A SATISFACTORY JOB SITE DEMONSTRATION FOR EACH PROJECTAND APPROVAL BY THE OWNER'S REPRESENTATIVE. NAIL HEADS THAT PENETRATE THE OUTER PLY MORE THANWOULD BE NORMAL FOR A HAND HAMMER OR IF THE MINIMUM ALLOWABLE EDGE DISTANCES ARE NOTMAINTAINED THE INSTALLATION IS UNSATISFACTORY. MACHINE NAILING IS NOT APPROVED IN 5/16" OR LESSSHEATHING.

3. DIAPHRAGM NAILING TO BE INSPECTED BEFORE COVERING. FACE GRAIN OF PLYWOOD TO BEPERPENDICULAR TO SUPPORTS. DIAPHRAGM SHEATHING MUST BE BLOCKED AT EDGES. PLYWOOD SPANS SHALLCONFORM WITH TABLE 2304.8(1).

4. GLUE FLOOR SHEATHING AT ALL POINTS OF CONTACT.

- E. PROVIDE MINIMUM NAILING PER TABLE 2304.9.1 OF THE IBC/CBC, UON

FASTENING SCHEDULE

CONNECTION NAILING STAPLES LOCATION

1 JOIST TO SILL OR GIRDER 3-8d COMMON 3-3" 14 GA STAPLES TOE NAIL

2 BRIDGING TO JOISTS 2-8d COMMON 2-3" 14 GA STAPLES TOE NAIL, EA END

3SOLE PLATE TO JOISTS ORBLOCKING

16d COMMON @ 16" OC 3" 14 GA STAPLES @ 12" OC TYP FACE

4 TOP PLATE TO STUD 2-16d COMMON 3-3" 14 GA STAPLES END NAIL

5A STUD TO SOLE PLATE 4-8d COMMON 3-3" 14 GA STAPLES TOE NAIL

5B STUD TO SOLE PLATE 2-16d COMMON 3-3" 14 GA STAPLES END NAIL

6 DOUBLE STUDS 16d COMMON @ 24" OC 3" 14 GA STAPLES @ 8" OC FACE

7A DOUBLE TOP PLATE 16d COMMON @ 16" OC 3" 14 GA STAPLES @ 12" OC TYP FACE

7B DOUBLE TOP PLATE 8-16d COMMON 12-3" 14 GA STAPLES LAP

8BLOCKING BETWEEN JOISTSOR RAFTERS TO TOP PLATE

3-8d COMMON 3-3" 14 GA STAPLES TOE NAIL

9 RIM JOISTS TO TOP PLATE 8d COMMON @ 6" OC 3" 14 GA STAPLES @ 6" OC TOE NAIL

10TOP PLATES, LAPS ANDINTERSECTIONS

2-16d COMMON 3-3" 14 GA STAPLES FACE

11 CONT HEADER, TWO PIECES 16d COMMON - 16" OC ALONG EDGE

12 CEILING JOISTS TO PLATE 3-8d COMMON 5-3" 14 GA STAPLES TOE NAIL

13 CONT HEADER TO STUD 4-8d COMMON - TOE NAIL

14CEILING JOISTS, LAPS OVERPARTITIONS

3-16d COMMON 3-3" 14 GA STAPLES FACE

15CEILING JOISTS PARALLEL TORAFTERS

3-16d COMMON 4-3" 14 GA STAPLES FACE

16 RAFTER TO PLATE 3-8d COMMON 3-3" 14 GA STAPLES TOE NAIL

17A BUILT-UP GIRDER BEAMS 20d COMMON @ 32" OC 3" 14 GA STAPLES @ 24" OCFACE NAIL @ T&BSTAGGERED

17B BUILT-UP GIRDER BEAMS 2-20d COMMON 3-3" 14 GA STAPLESFACE NAIL @ ENDS &EACH SPLICE

18 JOIST TO BAND JOIST 3-16d COMMON 4-3" 14 GA STAPLES TOE NAIL

PANEL THICKNESS MINIMUM GRADE ROOF/FLOOR RATING

3/8 STRUCTURAL 1 24/0

7/16 STRUCTURAL 1 24/16

15/32 STRUCTURAL 1 32/16

19/32 AND 5/8 CD/CC 40/20

3/4 CD/CC 48/24

7/8 AND 1 CD/CC 54/32

1 1/8 CD/CC 60/48

1901

11 S

UD ­

STRU

CTUR

AL P

ROGR

ESS

Page 3: GENERAL NOTES, ABBREVIATIONS, & SHEET LIST · 2019-07-15 · dc -6 wind design: dc dc -1 design criteria dc -2 dc -3 live loads ... scbf special concentrically braced frame sched

MIN BAR SPACING:1 1/2" OR 1 1/2d WHICHEVERIS LARGER

MAX BAR SPACING:Ls/5 OR 6"

BBAR SPACING FOR BARS SPLICED

WITH A NON-CONTACT LAP

ABAR SPACING FOR NON-SPLICED BARS

d

WIRE TOGETHEREACH END

CROSS TIE

ALTERNATE CROSS TIE END IN ALL CASES

DETAILDIMENSION FOR DEFORMED BARS IN TENSION:

D = 6d FOR #3 THRU #8 BARSD = 8d FOR #9 THRU #11 BARSD = 10d FOR #14 AND #18 BARS

BEAM

UON

Ls

Lext

D

d

LC

3" M

IN6d

D

D

3" M

IN6d

Lext

2 1/2" MIN

4d

DD

UO

N

12d

dd

d

d

ASTANDARD HOOK DETAILS

BTIE LAP DETAIL

EBEAM & JOIST STIRRUP

DCOLUMN & SPANDREL TIE

CSPANDREL & BEAM

SUPPLEMENTARY TIE

FOR STIRRUPS, TIES, AND HOOPS:FOR #3 THRU #5 BARS: D = 4d, Lext = 6d, 3" MINFOR #6 THRU #8 BARS: D = 6d, Lext = 12d

DETAILDIMENSION

5. Ld = DEVELOPMENT LENGTH(ACI 318-14 TABLE 25.4.2.2)

Ldh = HOOK DEVELOPMENT LENGTH(ACI 318-14 25.4.3)

Ls = LAP SPLICE LENGTH(ACI 318-14 TABLE 25.5.2.1)

COUPLER OR WELDED SPLICE

7. STAGGER SPLICES AS INDICATED ON DRAWINGS.

WHEN SPLICING BARS OF DIFFERENT SIZE, USE LAP SPLICE LENGTH OF LARGER BAR, UON.6.

Ls

Ls Ls2'-0" CLR MIN

2'-0" CLR MIN

NOTE: WHERE COUPLER OR WELDED SPLICE CAN DEVELOP 125% OF THE YIELD STRENGTH OF THE REINFORCING BAR, STAGGERING OF THE SPLICES IS NOT REQUIRED.

4. MORE THAN 12" OF CONCRETE CAST BELOW THE BARS ARE MOST TOP BARS. LESS THAN 12" OF CONCRETE CAST BELOW HORIZONTAL BARS ARE ALL VERTICAL BARS AND MOST BOTTOM BARS.

NOTES:1. YIELD STRENGTH OF REINFORCEMENT = 60 KSI2. UNCOATED OR ZINC-COATED (GALVANIZED) REINFORCEMENT 3. VALUES SHOWN FOR NORMAL WEIGHT CONCRETE ONLY, MULTIPLY BY 1.3 FOR LIGHTWEIGHT.

CONDITION A

CLEAR SPACING OF BARS OR WIRES BEING DEVELOPED OR LAP SPLICED > d, STIRRUPS OR TIES THROUGHOUT Ld NOT LESS THAN CODE MINIMUM

CONDITION B

CLEAR SPACING OF BARS OR WIRES BEING DEVELOPED OR LAP SPLICED > 2d, CLEAR COVER > d

CONDITION C

OTHER CASES

≥ d

NOTE: TABULATED VALUES FOR BEAMS OR COLUMNS ARE BASED ON TRANSVERSE REINFORCEMENT MEETING MINIMUM CODE REQUIREMENTS.

8. Ls VALUES MAY BE REDUCED IF CLASS A SPLICE IS USED, SEE ACI 318-14 TABLE 25.5.2.1

9. Ldh VALUES MAY BE REDUCED, SEE ACI 318-14 25.4.3

Ld

Ldh

ELEVATION SECTION

≥ d

≥ 2

d

ELEVATION

≥ d

≥ 2d

SECTION

≥ d

≥ d

≥ d

TH

OM

AS

CA

LU

S

16

20

SU

MM

ITR

IDG

E D

RIV

E,

BE

VE

RL

Y H

ILL

S, C

A 9

02

10

SU

D

da

tesh

ee

t title

sh

ee

t nu

mb

er

revis

ion

sclie

nt

dra

wn b

y

da

te

f:e

:31

0. 4

24.5

230

p:31

0.92

9.78

15in

fo@

dom

aen.

net

915

mat

eo s

treet

suite

205

los

ange

les

ca

9002

1

ww

w.d

omae

n.ne

t

EXP 03/31/2019C80463

STATE OF CALIFORN IA

ELIZ

ABE H MAHLOW

REG

IST

ERED

PROFESS IONA L ENGIN

EER

C I V IL

T

600

WIL

SH

IRE

BLV

D, S

UIT

E 7

60LO

S A

NG

ELE

S, C

A 9

0017

213

627

6687

CO

NTA

CT

@N

OU

SE

NG

INE

ER

ING

.CO

M

NOT FOR CONSTRUCTION

TY

PIC

AL

CO

NC

RE

TE

DE

TA

ILS

- R

EB

AR

S0.

10

AS

P

01/0

4/1

9

NOT TO SCALE

BAR SPACING IN CONCRETE4

NOT TO SCALE

BAR BENDING DETAIL10

NOT TO SCALE

REINFORCING DEVELOPMENT & SPLICE LENGTHS7

CONCRETE REINFORCING DEVELOPMENT & SPLICING LENGTHS (IN) FOR f'c = 3.0 KSI

CONDITIONCONCRETE

TYPE

REINFORCING BAR SIZE

#3 #4 #5 #6 #7 #8 #9 #10 #11

Ld Ls Ldh Ld Ls Ldh Ld Ls Ldh Ld Ls Ldh Ld Ls Ldh Ld Ls Ldh Ld Ls Ldh Ld Ls Ldh Ld Ls LdhTHICKNESS OF FRESH CONCRETE PLACED BELOW HORIZONTAL REINFORCEMENT > 12"

A & B NWC 21 28 8 28 37 11 36 46 14 43 56 16 62 81 19 71 93 22 80 104 25 90 118 28 100 131 31

C NWC 32 42 8 43 56 11 53 69 14 64 83 16 93 121 19 107 139 22 120 157 25 136 176 28 151 196 31

THICKNESS OF FRESH CONCRETE PLACED BELOW HORIZONTAL REINFORCEMENT ≤ 12"

A & B NWC 16 21 8 22 28 11 27 36 14 33 43 16 48 62 19 55 71 22 62 80 25 70 90 28 77 100 31

C NWC 25 32 8 33 43 11 41 53 14 49 64 16 72 93 19 82 107 22 93 120 25 104 136 28 116 151 31

CONCRETE REINFORCING DEVELOPMENT & SPLICING LENGTHS (IN) FOR f'c = 5.0 KSI

CONDITIONCONCRETE

TYPE

REINFORCING BAR SIZE

#3 #4 #5 #6 #7 #8 #9 #10 #11

Ld Ls Ldh Ld Ls Ldh Ld Ls Ldh Ld Ls Ldh Ld Ls Ldh Ld Ls Ldh Ld Ls Ldh Ld Ls Ldh Ld Ls LdhTHICKNESS OF FRESH CONCRETE PLACED BELOW HORIZONTAL REINFORCEMENT > 12"

A & B NWC 17 22 6 22 29 8 28 36 11 33 43 13 48 63 15 55 72 17 62 81 19 70 91 22 78 101 24

C NWC 25 32 6 33 43 8 41 54 11 50 65 13 72 94 15 83 108 17 93 121 19 105 137 22 117 152 24

THICKNESS OF FRESH CONCRETE PLACED BELOW HORIZONTAL REINFORCEMENT ≤ 12"

A & B NWC 13 17 6 17 22 8 21 28 11 25 33 13 37 48 15 42 55 17 48 62 19 54 70 22 60 78 24

C NWC 19 25 6 25 33 8 32 41 11 38 50 13 56 72 15 64 83 17 72 93 19 81 105 22 90 117 24

1901

11 S

UD ­

STRU

CTUR

AL P

ROGR

ESS

Page 4: GENERAL NOTES, ABBREVIATIONS, & SHEET LIST · 2019-07-15 · dc -6 wind design: dc dc -1 design criteria dc -2 dc -3 live loads ... scbf special concentrically braced frame sched

A

AS S

FOOTING/GRADE BEAM WHERE OCCURS

STD HOOKTYP

STD HOOK TYP

FOOTING LONGITUDINAL BAR TYP

FOOTING/GRADE BEAM LONGITUDINAL BAR TYP PLAN

LONGITUDINAL BARSCONT

2" TO FIRST TIE TYP

0", T

YP

0", T

YP

TYP

2" TO FIRST TIE OR HORIZONTAL BAR

TYP

2" T

O F

IRS

T T

IE O

R

HO

RIZ

ON

TAL

BA

R

TOP BAR LAP SPLICE AT MIDSPAN AS REQUIRED

TYP TOP BARS CONTINUOUST1 & T2

BOTTOM BAR LAP SPLICE OVER FOOTING AS REQUIRED

TYP CONTINUOUS BOTTOM BARS B1 &B2

TYP TIES PER SCHEDULE

NOTES:1. FIRST TIE AT THE SUPPORT SHALL BE PLACED

NO MORE THAN 2" FROM FACE OF SUPPORT.

TYP

TIES @ 4" OC AT SPLICES

TYP

0"

TOC

TIES S1

D1

TIES S1

D1

TIES S1

D1

TIES S1

D1

TIES S1

D1

B1 & B2 BOTTOM REINFORCING PER SCHEDULEWHERE REQUIRED

T1 & T2 TOP REINFORCING PER SCHEDULE WHERE REQUIRED

TIES PER SCHEDULE W/ ALTERNATE 90 DEG HOOKS EACH SIDE

HOOKED DOWELS TO MATCH SLAB REINFORCING

SIDE BARS EACH SIDE PER SCHEDULE

TYP

3"

SLAB ON GRADE PER PLAN

FINISH GRADE OR PAVING WHERE OCCURS

CURB PER ARCH WHERE OCCURS

SEE PLAN

PE

R S

CH

ED

ULE

D

PER SCHEDULE

W

MIN6"

TY

P

Ld

B1 & B2 BOTTOM REINFORCING PER SCHEDULEWHERE REQUIRED

T1 & T2 TOP REINFORCING PER SCHEDULE WHERE REQUIRED

TIES PER SCHEDULE W/ ALTERNATE 90 DEG HOOKS EACH SIDE

SLAB ON GRADE PER PLAN

HOOKED DOWELS TO MATCH SLAB REINFORCING

SIDE BARS EACH SIDE PER SCHEDULE

0" T

YP

TYP

3"

PE

R S

CH

ED

ULE

D

PER SCHEDULE

W

TY

P

Ld

1

1

SCHEDULED REINF #5 Z-BARS TO MATCH SPACING OF SCHEDULED REINF

NOTES:1. LOCATION OF PROPOSED CONSTRUCTION JOINTS SHALL BE SUBMITTED

TO THE OWNERS REPRESENTATIVE FOR APPROVAL.2. IN GENERAL JOINTS SHALL BE WITHIN THE MIDDLE THIRD OF THE SPAN.

LAP REBAR AT JOINT LOCATION OR PROVIDE REBAR SPLICE COUPLERW/ CAPACITY = 1.25AsFy

SECOND POURFIRST POUR

3 1/2"

2/3

DE

PTH

PILE CAP OR GRADE BEAM PER PLAN (REINFORCEMENT NOT SHOWN FOR CLARITY)

CLEAN AND ROUGHEN TO 1/4" AMPLITUDE

STD HOOK TYP

TIE SIZE AND SPACINGPER SCHEDULE

ASECTION

DIA AND REINFORCEMENT PER SCHEDULE

TERMINATE SPIRAL WITH DOUBLE LOOP T&B AND ADJOINING CAGES

VERTICAL BARPER SCHEDULE

3" CLR

FIL

L, F

AS

SU

ME

D

DE

PT

H O

FE

MB

ED

DE

PT

H IN

BE

DR

OC

K, D

LEN

GT

H O

F P

ILE

, L

Ldh

HOOKED DOWELS TO MATCH SLAB REINFORCING

TYP

Ls

REINFORCING PER SCHEDULE

PE

R S

CH

ED

ULE

D

PER SCHEDULE

W

TY

P

Ld

MIN

1'-0

"

ADDITIONAL BOTTOM BARS TO MATCH WALL REINFORCING

TY

P

Ls

#4 @ 1'-6" OC AT CURB

FINISHED GRADE OR PAVING WHERE OCCURS

#4 CONTINUOUS AT CURB

SLAB ON GRADE PER PLAN

10 MIL VAPOR BARRIER MIN SHALL BE IN DIRECT CONTACT WITH CONCRETE PER GEOTECH

4" MIN BASE OF 1/2" CLEAN AGGREGATE

FOR SUBGRADE PREPARATION SEE GEOTECHNICAL REPORT AND SPECIFICATIONS

(2) #4 CONTINUOUS

(2) #4 CONTINUOUS

UO

N

6"

1/8" WIDE SAWCUT CONTROL JOINT

BSLAB-ON-GROUND

AEDGE OF SLAB ON GROUND

HOOKED DOWELSSIZE TO MATCHSLAB REINFORCING

Ls

0" T

YP

CURB LOCATION PER ARCH

CLR

3 1/

32"

CLR3"

SLA

B T

HK

/ 4

1'-0"

2'-0

" M

IN

CONSTRUCTION JOINT W/ BOND BREAKER AND 1/8" WIDE SAWCUT

DIAMOND PLATE DOWEL INSTALL PER MANUFACTURER RECOMMENDATIONS

SLAB REINFORCING

CONSTRUCTION JOINT W/ BOND BREAKER AND 1/8" WIDE SAWCUT

SMOOTH DOWEL MATCH REINFORCING DIA AND SPACING, GREASE ONE SIDE

TYP

2" MAX3/4" MIN CLR

ACONSTRUCTION JOINT

SLAB ON GRADE ≥ 5" THICKB

CONSTRUCTION JOINT

SLAB ON GRADE < 5" THICK

NOTES:1. EITHER CONTROL OR CONSTRUCTION JOINTS SHALL BE LOCATED NO FURTHER THAN 36 x SLAB THICKNESS UNLESS A SMALLER SPACING IS

INDICATED ON DRAWINGS. ASPECT RATIO OF ENCLOSED AREA SHALL NOT EXCEED 1.5, SUBMIT LAYOUT FOR APPROVAL. LOCATE JOINTS ON COLUMN LINES AND UNDER PARTITIONS WHEREVER POSSIBLE. MAXIMUM SLAB AREA CONTROLLED BY JOINTING IS 400 SQ FT SAWCUT SHALL BE MADE AS SOON AS POSSIBLE AFTER SLAB FINISHING AS MAY SAFELY BE DONE WITHOUT DISLODGING AGGREGATE OR BREAKING EDGES, FILL SAWCUT JOINT WITH SEALANT AFTER SLAB HAS CURED.

CONCRETE NOT REINFORCED

HSS OR WF COLUMN

EDGE OF SLAB

4" MIN TYP OR AS NECESSARYTO ALLOW FOR INSTALLATION OF BASE PLATE

SLAB BLOCK OUT AT COLUMN

CPLAN-SLAB BLOCKOUT

AT COLUMND

PLAN-SLAB BLOCKOUT

AT EDGE COLUMN

0" T

YP

SLAB REINFORCING

JOINT LAYOUT

CURB OR STARTER WALL(3 1/2" STARTER WALL MIN FOR FOOTING BELOW GRADE)

AFTER SET- CLEAN TO REMOVE LAITANCE AND SCUM

FORMWORK SPECIFICATIONS APPLICABLE

2" PLANKING TYP

NOTES:1. STAKES NOT PERMITTED WITHIN FOOTING SECTION.

FORMWORK NOT PERMITTED BELOW GRADE UNLESS FULLY FORMED

CUT BACK SPALL

2" M

IN

MIN

1'-6"

MA

X 3'

-0"

4" M

INE

Q

TYP1" CLR

PIPE SLEEVE

CONT FOOTING

1

1

FTG WIDTH

MATCH

PE

NE

TRA

TIO

NS

NO

DO NOT EXCAVATE PARALLEL TO FOOTING BELOW THIS LINE

CONCRETE OR LEAN CONCRETE FILL PLACE A MIN OF (3) DAYS BEFORE PLACING FOOTING

JOINT

ASECTION

NOTES:1. REINFORCING OPENINGS FOR SLEEVES OR GROUPS OF SLEEVES LARGER THAN 10" PER THE WALL REINFORCING

AT OPENINGS TYPICAL DETAIL.2. SEE MECHANICAL & CIVIL DRAWINGS FOR ADDITIONAL REQUIREMENTS AT SLEEVES. DEPTH OF FOOTING MAY BE

DETERMINED BY LOCATION OF PIPES. CONSULT WITH MECHANICAL CONTRACTOR TO DETERMINE EXACT DEPTH.

CLR3"

CLR3"

DOWEL TO MATCH FOOTING OR WALL REINFORCEMENT WHERE REQUIRED

18

"

MA

XT

YP

D

CLR3"

BENT BARS; SIZE AND QTY OF BARS TO MATCH FOOTING BEYOND

2'-0" MIN, MAINTAIN DEPTH (D) OF FOOTING THROUGH STEP

MIN

D

3"

CLR

3"

STEP IN TOP OF FOOTING ON PLAN

DENOTES APPROXIMATE LOCATION OF STEP IN FOOTING CONTRACTOR TO COORDINATE ELEVATION

3"

2 MIN1

NOTES:1. SEE FOOTING SCHEDULE FOR FOOTING DIMENSIONS

AND REBAR SIZE AND SPACING.2. PROVIDE TIES PER SCHEDULE THROUGH FOOTING

STEPS AS SHOWN.

TYP

Ls

TOC

NOTES:1. PROVIDE 6" MIN CONCRETE COVER OVER COLUMN BASE PLATE AND ANCHOR RODS BELOW GRADE, TYPICAL.

HOOKED DOWELS TO MATCH SLAB REINFORCING

TYP

Ls

REINFORCING PER SCHEDULE

PE

R S

CH

ED

ULE

D

PER SCHEDULE

W

BASE PLATE PER COLUMN SCHEDULE

SLAB-ON-GRADEWITH REINFORCEMENTPER PLAN

Ld, TYPWHERE Ld DOES NOT FIT,CHANGE TO Ldh AND HOOK BARS

TH

OM

AS

CA

LU

S

16

20

SU

MM

ITR

IDG

E D

RIV

E,

BE

VE

RL

Y H

ILL

S, C

A 9

02

10

SU

D

da

tesh

ee

t title

sh

ee

t nu

mb

er

revis

ion

sclie

nt

dra

wn b

y

da

te

f:e

:31

0. 4

24.5

230

p:31

0.92

9.78

15in

fo@

dom

aen.

net

915

mat

eo s

treet

suite

205

los

ange

les

ca

9002

1

ww

w.d

omae

n.ne

t

EXP 03/31/2019C80463

STATE OF CALIFORN IA

ELIZ

ABE H MAHLOW

REG

IST

ERED

PROFESS IONA L ENGIN

EER

C I V IL

T

600

WIL

SH

IRE

BLV

D, S

UIT

E 7

60LO

S A

NG

ELE

S, C

A 9

0017

213

627

6687

CO

NTA

CT

@N

OU

SE

NG

INE

ER

ING

.CO

M

NOT FOR CONSTRUCTION

TY

PIC

AL

CO

NC

RE

TE

DE

TA

ILS

-F

OU

ND

AT

ION

S &

SLA

B O

N G

RA

DE

S0.

11

AS

P

01/0

4/1

9

NOT TO SCALE

FOOTING/GRADE BEAM REINFORCING ATCORNERS AND INTERSECTIONS

1

NOT TO SCALE

PILE GRADE BEAM REINFORCING ELEVATION10

NOT TO SCALE

EXTERIOR GRADE BEAM13 NOT TO SCALE

INTERIOR GRADE BEAM9 NOT TO SCALE

CONSTRUCTION JOINT AT GRADE BEAM5

NOT TO SCALE

FRICTION PILE3NOT TO SCALE

CONCRETE WALL CONTINUOUS FOOTING7

NOT TO SCALE

SLAB ON GRADE & CONTROL JOINT4

NOT TO SCALE

SLAB ON GRADE CONSTRUCTION JOINT AND BLOCKOUT PREPARATION15

NOT TO SCALE

MANDATORY MINIMUM FORMWORKAND FOUNDATION EXCAVATION REQUIREMENTS

16 NOT TO SCALE

PIPE & TRENCH PENETRATIONSAT WALL FOOTING

12 NOT TO SCALE

STEPS IN CONTINUOUS FOOTING8

NOT TO SCALE

STEEL COLUMN CONTINUOUS FOOTING14

1901

11 S

UD ­

STRU

CTUR

AL P

ROGR

ESS

Page 5: GENERAL NOTES, ABBREVIATIONS, & SHEET LIST · 2019-07-15 · dc -6 wind design: dc dc -1 design criteria dc -2 dc -3 live loads ... scbf special concentrically braced frame sched

NOTES:1. SLAB THICKNESS AND REINFORCEMENT PER PLAN.

ATOP OF SLAB STEP

BBOTTOM OF SLAB STEP

STD HOOK

Ld

PE

R P

LAN

ST

EP

STD HOOK

Ld

PE

R P

LAN

ST

EP

NOTES:1. WHERE MULTIPLE CONSECUTIVE STEPS OCCUR, ADDED Z-BARS SHALL BE CONTINUOUS OVER ALL STEPS.

TYP

Ls MIN

Z-BARS TO MATCH SLABREINFORCING SIZE ANDSPACING

ADDITIONAL LONG BARS TO MATCH SIZE AND SPACING OF SLAB REINFORCEMENT

SLAB PER PLAN

SLAB

THICKNESSTO MATCH

SE

E N

OT

E 1

d, P

ER

PLA

N

12

SLAB REINFORCEMENT PER PLAN

.

12 MINSLAB REINFORCEMENT

PER PLAN.

12MIN

MIN

SIZE AND SPACING TO MATCH BOTTOM REINFORCING

SIZE AND SPACING TO MATCH BOTTOM REINFORCING

Ls

1'-0" MIN

4Xd UON Ls

Ls

PE

R P

LAN

STE

P d

<10"

LOC

AT

ION

AN

D D

EP

TH

PE

R P

LAN

STE

P d

<10"

LOC

AT

ION

AN

D D

EP

TH

Ls

4Xd UON

Ls

Ls

#4 U-BARS @ 1'-0" OC

(4) ADDITIONAL #6 EDGE BARS UON

STD HOOK TYP

TY

P

±1'

-0"

TO

SU

IT R

EIN

F

TY

P

±1'

-0"

BEVEL EDGES 45°

ROUGHEN ALL CONSTRUCTION JOINT SURFACES TO 1/4" AMPLITUDE MIN TYP

NOTES: 1. DETAILS APPLY TO BOTH HORIZONTAL AND VERTICAL CONSTRUCTION JOINTS.2. KEY TYPE#1 - TYPICAL FOR WALLS.3. KEY TYPE #2 - FOR SLABS, RETAINING WALLS AND EXTERIOR WALLS BELOW

GRADE.

T <8"

8"-16" >16"

D3/4"

1 1/2"2 1/2"

KEY SCHEDULE

T T

D

T/3 T/3

D/2

AKEY TYPE #1

BKEY TYPE #2

RC WALL PER PLAN

HOOKED DOWELS TO MATCH WALL REINFORCEMENT SIZE AND SPACING

SLAB PER PLAN

TY

P

Ls

NOTES:1. CONTRACTOR TO PROVIDE ADEQUATE SHORING OF SLAB DURING

CONSTRUCTION AND CURING OF CONCRETE WALLS ABOVE.

RC WALL PER PLAN

SLAB PER PLAN

NOTES:1. WHERE DOWELS ARE INTERRUPTED BY SLAB OPENINGS

PROVIDE THE DOWEL ON OPPOSITE FACE FOR LENGTH OF OPENING.

ALTERNATIVELY END REBAR WITH T-HEAD

RC WALL PER PLAN

DOWEL TO MATCH SIZE AND SPACING OF THICKER WALL VERTICAL REINFORCEMENT

SLAB PER PLAN

ALTERNATIVELYEND BAR WITH T-HEAD

STD HOOK TYP

Ls

Ld

Ls

TY

P

Ls

NOTES:1. LCN DENOTES LARGER OF ADJACENT CLEAR SPANS.2. ADDITIONAL MULTI-BAY BOTTOM BARS TO BE SPLICED AS SHOWN ABOVE AND EXTEND 6" INTO SUPPORT AT BAR END.

CLEND

SUPPORT

CLINTERIORSUPPORT

CLINTERIORSUPPORT

SE

E P

LAN

CLE

AR

CO

VE

R

CLEAR

2"

SEE PLAN

BAR EXTENT

SEE PLAN

BAR EXTENT

LC1 - END CLEAR SPAN

SEE PLAN

BAR EXTENT

LC2 - INTERIOR CLEAR SPAN

SEE PLAN

BAR EXTENT

SEE PLAN

BAR EXTENT

SE

E P

LAN

CLE

AR

CO

VE

R

TY

P

0"

FOR ALL BOTTOM BARS

LTS PERMITTED IN THIS REGION

TYPICAL

6"

BOTTOM BARSSEE PLAN

ADDITIONAL TOP BARS SEE PLAN

ADDITIONAL SINGLE BAYBOTTOM BARS, SEE PLAN

90° STANDARD HOOKTILT FROM VERTICALIF NECESSARY TO MAINTAINCLEAR COVER

EXTEND TWO BOTTOM BARSIN COLUMN STRIP TO PASSTHROUGH COLUMN CORESAND BE TERMINATED WITHSTANDARD 90° HOOK

SE

E P

LAN

T

WIDTH

COLUMN

TYPICAL

6"

TYP

0.30 LCN

TYP

0.30 LCN

TOP BARS SEE PLAN

NOTES:1. COLUMN LOCATIONS PER PLAN.2. PLACE ADDITIONAL BARS BETWEEN LAYERS OF SCHEDULED ORTHOGONAL REINFORCEMENT.

SLAB EDGE

COLUMN

A

B

2"

COLUMN OR SHEAR HEAD EXTENT

(5) #5 @ 8" OC ADDITIONAL BARS TOP & BOTTOM, EACH SIDETYP

LC

COLUMNLC

TYP

6'-0"

NOTES:1. L = LONGER SLAB SPAN

OF THE TWO DIRECTIONS

BOTTOM BARS#5 @ 8" OC(5) MIN

TOP BARS#5 X 5'-6" LONG @ 8" OC

THK

WALL

TH

K

WA

LL

L/5

TYP

18" MIN TO BOTTOM BAR

L/5

TERMINATE SLAB REINFORCING WITH STD HOOK INTO PERIMETER BEAMS TYP

OPEN

PROVIDE 1/2 OF INTERRUPTEDREINFORCEMENT AT EACHSIDE OF OPENING @ 3" OC (2) BARS MINNONE REQUIRED IF NO INTERRUPTED REINFORCEMENT

OPPOSITE FACE OF BEAM OR WALL

(1) #5 AT EACH CORNERCENTERED IN SLAB

NOTE:1. AT EDGE OF SLAB LOCATIONS, HOOK REINFORCEMENT INTO

OPPOSITE FACE OF WALL OR BEAM.

STD 180° HOOK AT INTERRUPTED T & B SLAB REINFORCING AT OPENING TYP

MAX

6'-0"

TYP

Ld

EQ

EQ

TYP6"

MIN

TYP3" MAX CLR

NOTES:1. D=CONDUIT OR PIPE DIAMETER2. S=SLEEVE DIAMETER3. WHERE PIPE OR SLEEVE SPACING IS LESS

THAN SHOWN, REINFORCE AS A SINGLE OPENING. FOR WALLS, SEE TYPICAL

OPENING DETAIL. FOR SLABS, SEE TYPICAL GROUPED OPENING DETAIL. IF EFFECTIVE OPENING DIMENSION EXCEEDS 2'-0" (4'-0" FOR SLABS) CONTACT ARCHITECT BEFORE PROCEEDING.

3S OR 3D (4" MIN)

CLR SPACINGLARGER OFD

S

EQ MIN

EQ 1" CLR

CONDUIT IN SLAB OR WALL

(4) #5 DIAGONAL TYP

END OF SLAB OR WALL

D =

T/4

(2"

MA

X) A

T W

ALL

D =

1"

MA

X A

T S

LAB

S

LC

ASECTION WITHIN SLAB OR WALL

BSECTION THRU SLAB

4D MIN AT WALLS3D MIN AT SLABS

PR

OTE

CTI

ON

3"

NOTES:1. WHERE CLEAR DISTANCE BETWEEN ADJACENT HOLES IS LESS THAN 3D (MIN 8" MIN) PROVIDE REINFORCING AS FOLLOWS:2. REINFORCING AS SINGLE OPENING USING "EFFECTIVE OPENING OUTLINES" AS SHOWN.3. PROVIDE (1) #5 TOP & BOTTOM TRIM BARS AROUND "EFFECTIVE OPENING WITH 12" EMBEDMENT BEYOND THE OPENING EDGE.4. WHERE "L" EXCEEDS 2'-0" PROVIDE DIAGONAL CORNERS BARS AND REINFORCING AS PER TYPICAL STRUCTURAL CONCRETE

SLAB OPENING DETAIL.5. IF EFFECTIVE OPENING LENGTH EXCEEDS 4'-0" NOTIFY ARCHITECT AND/OR STRUCTURAL ENGINEER BEFORE PROCEEDING.6. CONTINUE TYPICAL REINFORCING BETWEEN INDIVIDUAL HOLES WHERE POSSIBLE. AN EQUIVALENT AMOUNT OF ANY

INTERRUPTED REINFORCING SHALL BE ADDED AT EACH SIDE OF GROUPED OPENINGS.

REINFORCING PER NOTE 5 3D D

EFFECTIVE OPENING OUTLINE TYP

BASE PLATE AND ANCHOR BOLTS PER SCHEDULE

SLAB REINFORCMENT TOP AND BOTTOM PER PLAN

1" THK HIGH STRENGTH NON-SHRINK GROUT

.

WHERE NOTED ON PLAN PROVIDE ADDITIONAL SADDLE BARS @ 6" OC EACH WAY

T

T/2

1

1

TH

OM

AS

CA

LU

S

16

20

SU

MM

ITR

IDG

E D

RIV

E,

BE

VE

RL

Y H

ILL

S, C

A 9

02

10

SU

D

da

tesh

ee

t title

sh

ee

t nu

mb

er

revis

ion

sclie

nt

dra

wn b

y

da

te

f:e

:31

0. 4

24.5

230

p:31

0.92

9.78

15in

fo@

dom

aen.

net

915

mat

eo s

treet

suite

205

los

ange

les

ca

9002

1

ww

w.d

omae

n.ne

t

EXP 03/31/2019C80463

STATE OF CALIFORN IA

ELIZ

ABE H MAHLOW

REG

IST

ERED

PROFESS IONA L ENGIN

EER

C I V IL

T

600

WIL

SH

IRE

BLV

D, S

UIT

E 7

60LO

S A

NG

ELE

S, C

A 9

0017

213

627

6687

CO

NTA

CT

@N

OU

SE

NG

INE

ER

ING

.CO

M

NOT FOR CONSTRUCTION

TY

PIC

AL

CO

NC

RE

TE

DE

TA

ILS

- E

LEV

AT

ED

SLA

B R

EIN

FO

RC

ING

S0.

12

AS

P

01/0

4/1

9

NOT TO SCALE

CHANGE IN SLAB THICKNESS3

NOT TO SCALE

STEP IN SUSPENDED SLAB2

NOT TO SCALE

STEP IN SUSPENDED SLAB4

NOT TO SCALE

SLAB EDGE REINFORCEMENT6

NOT TO SCALE

CONSTRUCTION JOINTS IN CONC WALLSAND SLABS

7

NOT TO SCALE

RC WALL ON SLAB TRANSFER8

NOT TO SCALE

SLAB CONNECTION AT INTERIOR WALL10

NOT TO SCALE

SLAB CONNECTION AT END WALL9 NOT TO SCALE

TWO-WAY SLAB REINFORCING DETAIL5

NOT TO SCALE

ADDITIONAL REBAR AT SLAB CORNER (A/B<3)11

NOT TO SCALE

SLAB REINFORCING AT CORNER12

NOT TO SCALE

CONCRETE FLOOR OPENINGS13

NOT TO SCALE

CONDUIT AND PIPING AT SLAB OR WALL14

NOT TO SCALE

STRUCT SLAB OPENING 8" DIA OR LESS15

NOT TO SCALE

SHEAR REINFORCEMENT AT STEEL COLUMNON SLAB TRANSFER

16

1901

11 S

UD ­

STRU

CTUR

AL P

ROGR

ESS

Page 6: GENERAL NOTES, ABBREVIATIONS, & SHEET LIST · 2019-07-15 · dc -6 wind design: dc dc -1 design criteria dc -2 dc -3 live loads ... scbf special concentrically braced frame sched

A

A

A

OPEN

DIAGONAL REINFORCING

TRIM REINFORCING SCHEDULE

t > 16" (2) #8

6" < t < 9"

9" < t < 12"

WALL THICKNESS, t

12" < t < 16"

(2) #6

(2) #5

MIN TRIM REINFORCING

(2) #7

#7

#5

#5

#5

NOTES:1. SCHEDULE REINFORCEMENT APPLIES TO ALL OPENINGS UNLESS OTHERWISE SHOWN.2. MIN TRIM REINFORCEMENT TO BE LARGER OF TYPICAL WALL REINFORCEMENT OR SIZE SHOWN IN SCHEDULE.3. AT SERIES OF OPENINGS WHERE PIER OR SPANDREL IS NARROWER THAN THREE TIMES Ld, RUN TRIM

REINFORCEMENT CONTINUOUS ACROSS ALL OPENINGS.

4. MAY OMIT DIAGONALS IF THE LARGEST OPENING DIMENSION IS LESS THAN 3'-0".5. DETAIL IS NOT REQUIRED FOR OPENINGS SMALLER THAN THE WALL THICKNESS OR 12", WHICHEVER IS SMALLER.6. COORDINATE OPENING LOCATIONS AND SIZES WITH OTHER TRADES INCLUDING BUT NOT LIMITED TO

ARCHITECTURAL, MECHANICAL, ELECTRICAL, AND PLUMBING.

DIAGONAL REINFORCEMENTPER SCHEDULE(OMIT DIAGONAL AT FOUNDATION)

PROVIDE STD HOOK AT END OF WALL OR EDGE OF OPENING

180 DEG HOOK TO PROVIDE MIN CLEARANCE

TRIM REINFORCEMENT

TYP WALL REINFORCEMENT

TYP WALL REINFORCEMENT

TRIM REINFORCEMENT

STD HOOKROTATE TO PROVIDEMIN CLEARANCE

TRIM REINFORCEMENT PER SCHEDULE

48" MIN

SEE NOTE 3 Ld, 24" MIN

APLAN

SINGLE CURTAIN

APLAN

DOUBLE CURTAIN

t

6"

( TO END OF HOOKS)2" MAX 1" MIN

t

6"

Ld

Ld

STD 90° HOOKROTATE TO PROVIDE MIN CLEARANCE

(2) ADDITIONAL TRIM BARWALL REINFORCEMENT TOMATCH VERTICAL

TYP WALL REINFORCEMENTPER SCHEDULE

(2) ADDITIONAL TRIM BARS TO MATCH VERTICAL WALL REINFORCEMENTTYP UON

TYP WALL REINFORCEMENTSEE SCHEDULE.

(2) ADDITIONAL TRIM BARS TO MATCH VERTICAL WALL REINFORCEMENTTYP UON

.

ADOUBLE CURTAIN

REINFORCEMENT AT WALLB

SINGLE CURTAIN

REINFORCEMENT AT WALL

6" 3"6"

3" 6"

CORNER DETAIL

TERMINATE WALL REINFORCEMENTW/ STD 90° HOOK INTO COLUMN OR BOUNDARY ZONE

ALTERNATE 90° HOOK END FOR ENDTHROUGH HEIGHT OF BOUNDARY

WALL REINFORCEMENTPER SCHEDULE

VERTICAL BOUNDARY ZONE REINFORCEMENT PER SCHEDULE

3/4" CHAMFERTYP

1:6 MAX BEND BAR OFFSET TYP

VERTICAL REINFORCEMENTPER SCHEDULE

2'-0"

1'-0

1/3

2"

VERTICAL REINFORCEMENTPER SCHEDULE

TIES PER SCHEDULE BOUNDARY ZONE

L

NOTES:1. SEE DETAIL A FOR INFORMATION NOT SHOWN.

MIN TYP

> = Ldh OR Ld*

NOTES:1. *WHEN POSIBLE, Ld WITH STRAIGHT REBAR ELSE

USE HOOKED REBAR WITH Ldh.

TY

P

< =

6"

MIN

TY

P

> =

Ldh

OR

Ld< = 6"

FULLY TIGHTENED DOUBLE NUTS OR HEX BOLT HEAD W/ 3/8" THICK X 3" SQ WASHER.

MIN EMBEDMENT LENGTHPER COLUMN SCHEDULE

NOMINAL GROUT THICKNESS PER ANCHOR ROD SCHEDULE

HEAVY HEX NUT

SQ OR ROUND PLATE WASHER W/ STD HOLESIZE AND THICKNESS PER ANCHOR ROD SCHEDULE

MIN PROJECTION ABOVE BASE PLATE PER ANCHOR ROD SCHEDULE

THREAD LENGTH

BASE PLATE W/ OVERSIZED HOLE PER ANCHOR ROD SCHEDULE

MIN PROJECTION

ABOVEBASE PLATE

MINWASHER

THICKNESS

MINWASHER

SIZE

MAX ANCHOR ROD

HOLE DIAD*

ANCHORRODDIA

ANCHOR ROD SCHEDULE

NOMINALGROUT

THICKNESS

ANCHOR ROD PER ANCHOR RODSCHEDULE / COLUMN SCHEDULE

BASE OF CONCRETE

BASE PLATE THICKNESS

SETTING NUT AND PLATE WASHER (1/2" MIN WASHER THICKNESS) OR SHIM STACK AT CONTRACTORS OPTION / COORDINATION

3/4" 1 5/16" 2" 1/4" 3" 2"

1" 1 13/16" 3" 3/8" 3 1/2" 2"

1 1/4" 2 1/16" 3" 1/2" 4" 2"

1 1/2" 2 5/16" 3 1/2" 1/2" 4" 2"

1 3/4" 2 3/4" 4" 5/8" 5" 2"

2" 3 1/4" 5" 3/4" 5" 2"

2 1/2" 3 3/4" 5 1/2" 7/8" 5 1/2" 2"

D

WELDA

REMARKS

NOTES:1. WHERE WELD A IS NOT SHOWN, TACK-WELD AS REQUIRED FOR ERECTION.2. D* = RECOMENDED MAXIMUM ANCHOR ROD HOLE DIAMETER PER AISC TABLE 14-2.3. CIRCULAR OR SQUARE WASHERS MEETING THE WASHER SIZE ARE ACCEPTABLE.4. CLEARANCE MUST BE CONSIDERED WHEN CHOOSING AN APPROPRIATE ANCHOR ROD HOLE LOCATION. NOTING EFFECTS

SUCH AS POSITION OF THE ROD IN THE HOLE WITH RESPECT TO THE COLUMN, WELD SIZE, AND OTHER INTERFERENCES.5. WHEN BASE PLATES ARE LESS THAN 1 1/4" THICK, PUNCHING OF HOLES MAY BE AN ECONOMICAL OPTION. IN THIS CASE,

3/4" ANCHOR RODS AND 1 1/16" DIAMETER PUNCHED HOLES MAY BE USED WITH ASTM F844 (USS STANDARD) WASHER IN PLACE OF FABRICATED PLATE WASHERS.

A

SEE ANCHOR ROD SCHEDULEFOR WELD A

TOCELEV

1/4

1/4

3/8

3/8

1/2

1/2

3/4

MARK

A

B

C

D

E

F

G

7/8" 1 9/16" 2 1/2" 5/16" 3 1/2" 2" 1/4

H

CO

VE

R4"

MIN

2" M

IN

3" CONCRETE COVERMIN

CO

L S

CH

ED

EM

BE

D P

ER

BASE PLATE THICKNESS t

ANCHOR ROD DIA

EDGEDISTANCE

7/8" 2"

1" 2 1/4"

1 1/4" 2 3/8"

1 1/2" 2 5/8"

3/4" 1 1/2"

1 3/4" 3"

2" 3 1/2"

2 1/2" 4"

TYPICAL EDGE DISTANCE

SCHEDULE

(4) ANCHOR RODS

WF OR HSS COLUMNPER PLAN

NOTES:1. BASE PLATE SIZE, THICKNESS AND ANCHOR RODS PER COLUMN SCHEDULE.2. ANCHOR RODS, OVERSIZED HOLE AND WASHER REQUIREMENTS PER TYPICAL

ANCHOR ROD DETAIL.

COLUMNLC

5/16

AHSS (SQUARE PLATE)

2" THK GROUT TYP

BASE PLATETHICKNESS t

(4) ANCHOR RODS

5/16

BHSS (RECTANGULAR PLATE)

COLUMNLC

COLUMNLC

COLUMNLC

COLUMNLC

EQ EQ

N

EQ

EQ

B

TYP

EDGE DISTANCEPER SCHEDULE

N

EQ EQ

EQ

EQ

B

TYP

EDGE DISTANCEPER SCHEDULE

TH

OM

AS

CA

LU

S

16

20

SU

MM

ITR

IDG

E D

RIV

E,

BE

VE

RL

Y H

ILL

S, C

A 9

02

10

SU

D

da

tesh

ee

t title

sh

ee

t nu

mb

er

revis

ion

sclie

nt

dra

wn b

y

da

te

f:e

:31

0. 4

24.5

230

p:31

0.92

9.78

15in

fo@

dom

aen.

net

915

mat

eo s

treet

suite

205

los

ange

les

ca

9002

1

ww

w.d

omae

n.ne

t

EXP 03/31/2019C80463

STATE OF CALIFORN IA

ELIZ

ABE H MAHLOW

REG

IST

ERED

PROFESS IONA L ENGIN

EER

C I V IL

T

600

WIL

SH

IRE

BLV

D, S

UIT

E 7

60LO

S A

NG

ELE

S, C

A 9

0017

213

627

6687

CO

NTA

CT

@N

OU

SE

NG

INE

ER

ING

.CO

M

NOT FOR CONSTRUCTION

TY

PIC

AL

CO

NC

RE

TE

DE

TA

ILS

- W

ALL

RE

INF

OR

CIN

G &

CO

LUM

NS

S0.

13

AS

P

01/0

4/1

9

NOT TO SCALE

WALL REINFORCEMENT AT OPENINGS5

NOT TO SCALE

WALL REINFORCING AT CORNERS AND INTERSECTIONS6

NOT TO SCALE

WALL BOUNDARY REINFORCEMENT7

NOT TO SCALE

ANCHOR ROD DETAIL AND SCHEDULE13

NOT TO SCALE

STEEL COLUMN BASE PLATES15 19

0111

SUD

­ ST

RUCT

URAL

PRO

GRES

S

Page 7: GENERAL NOTES, ABBREVIATIONS, & SHEET LIST · 2019-07-15 · dc -6 wind design: dc dc -1 design criteria dc -2 dc -3 live loads ... scbf special concentrically braced frame sched

AA

A

NOTE:1. SEE DETAIL A FOR INFO NOT SHOWN.

ABEAM WITH SAME DEPTH

BBEAM WITH VARYING DEPTH

2 x bf2 x bf

bf+1 1/2"

bftf - 1/8"

& 1/4" MIN

tf - 1/8"& 1/4" MIN

tf - 1/8"& 1/4" MIN

BOTTOM PLATE THK TO MATCH FLANGE THK tf

bf - 1 1/2"

ELEVATION SECTION

TOP PLATE THK= tf x bf(bf - 1 1/2")

NO WELD TO SUPPORTING BEAM TOP FLANGE

SEE TYP BEAM TO BEAM CONNECTION

SUPPORTING BEAM

5/16 2

5/16 2

PLATE TO PASS THOUGH HOLE IN WEB. MAINTAIN 1/2" CLR AROUND FLANGE PLATE, RADIUS CORNERS

bf = SMALLER FLANGE WIDTH OF BEAMS

ELEVATION SECTION

NOTES:1. SEE DETAIL A & B FOR INFO NOT SHOWN.

bf = SMALLER FLANGE WIDTH OF BEAMS

ELEVATION SECTION

CSTEPPED BEAMS

NOTES:1. FLANGE PLATE TO BE ASTM A572, GR 50.2. NO ERECTION BOLTS ALLOWED IN FLANGE PLATES.3. NOTED ON PLAN BY

BS OF WEBtf-1/8 & 1/4 MIN

COPE FLANGES AS REQD 1" MAX BETWEEN FLANGES

2 ROWS OF BOLTS AND LARGER PLATE WHERE OCCURS

SHEAR PLATE & BOLTSPER SCHED

2 db MIN

COPE FLANGES AS REQD 1" MAX BETWEEN FLANGES

2 ROWS OF BOLTS AND LARGER PLATE WHERE OCCURS

SHEAR PLATE & BOLTSPER SCHED

2 ROWS OF BOLTS AND LARGER PLATE WHERE OCCURS

SHEAR PLATE & BOLTSPER SCHED

db=1

"

1 1/

2" T

YP

1 3/

4" W

HE

RE

2 db MIN

3" MAXUON

3" MAXUON

3" MAXUON

TYP

3"

TYP

3"TY

P

3"

2 db MIN

db=1

"

1 1/

2" T

YP

1 3/

4" W

HE

RE

db=1

"

1 1/

2" T

YP

1 3/

4" W

HE

RE

NOTES:1. db DENOTES BOLT DIA.2. FOR INFO NOT SHOWN SEE

BEAM CONNECTION SCHEDULE

COPE FLANGES AS REQD 1" MAX BETWEEN FLANGES

S2 SIDES PER SCHED

S2 SIDES PER SCHED

S2 SIDES PER SCHED

ASHALLOW SUPPORTED BEAM

BEQUAL DEPTH BEAMS

CDEEP SUPPORTED BEAM

DSHALLOW (d< 8") SUPPORTED BEAM

3/8" PLATE

W6 OR W8

(2)-7/8" DIA A325N BOLTS

5/16

3" TYP 2 1/2"

UON3" MAX

1 1/

2"

1" MAX

9", 10"

12", 14", C12, MC12

DEPTH OR SIZE OF

SMALLER BEAM

NOTES:1. USE LARGER WELDS OR COMPLETE PENETRATION WELDS AT ALL SKEWED CONNECTIONS PER TYP DETAILS.

2. MARKS ON PLANS INDICATES 2 ROWS OF BOLTS. EACH ROW TO HAVE THE NUMBER OF BOLTS IN THE TABLE ABOVE. SPACE ROWS AT 3" OC.

3. MARKS ON PLANS INDICATES FLANGE BRACE PER

4. MARKS ON PLANS INDICATES WELDED TOP FLANGE PER TYPICAL DETAILS.

5. DEPTH OR SIZE CORRESPONDS TO THE SMALLEST BEAM, SEE TYPICAL DETAILS.

6. PROVIDE SLIP CRITICAL CONNECTIONS AT ALL SLRS FRAMING.

2

F16"

18"

21"

24"

27"

30"

33" AND LARGER

NO OF BOLTS,A325N UON

(2)

(2) 7/8" DIA

ONE ROW OF BOLTS TWO ROWS OF BOLTS

SHEARPLATE

WELDSIZE

S

(1)

SHEARPLATE

5/8"1/4"

5/16"

7/16"

NO OF BOLTS PER ROW, 7/8" DIA A325SC UON

(2)

2

3

4

4

5

6

7

8

9

3/8"

1/2"

1/2"

1/2"

5/16"

5/16"

1/4"3/8"

1/4"3/8"

1/4"3/8"

1/4"3/8"

1/4"3/8"

5/8" 7/16"

5/8" 7/16"

5/8" 7/16"

5/8" 7/16"

5/8" 7/16"

5/8" 7/16"

5/8" 7/16"

5/8" 7/16"

T

WELDSIZE

S

(1)

(3) 7/8" DIA

(4) 7/8" DIA

(4) 7/8" DIA

(5) 7/8" DIA

(6) 7/8" DIA

(7) 7/8" DIA

(8) 7/8" DIA

(9) 7/8" DIA

W12 & SMALLER

W18 THRU W14

W36 THRU W21

CONNECTIONS

STAIR STRINGER

LOCATION

WF

2 SIDED STIFFENERAT ALL LOCATIONS WITHOUT CONCRETE SLAB ABOVE AND AS NOTED IN SCHEDULE

# OF PLATES

(1) SIDED

(2) SIDED

(2) SIDED

(2) SIDED

1/8"

WELD SIZE F

3/16"

1/4"

3/16"

STIFFENER/CONNECTION PLATEPER SCHEDULE

1/4"

1/2"

3/8"

3/8"

PLATE SIZE

NOTES:1. USE THIS DETAIL WHERE PLATES OR STIFFENERS ARE SHOWN BUT NOT DETAILED.2. WELD TO BE MAX OF AWS MIN AND SCHEDULE SIZE.

FPER SCHED

NOTE:1. FOR WELD, BOLTS, AND SHEAR PLATE SEE BEAM CONNECTION SCHEDULE (FOR LARGER BEAM). NOTE:

1. SEE TYPE A FOR INFO NOT SHOWN.

PLATE THICKNESS t1 1/2" MIN.

BOLTS PER SCHEDULE

k + 1/2" MAX.

ASAME DEPTH BEAMS

BUNEQUAL DEPTH BEAMS

1 1/2"

3"

1 1/2" MIN AT STD HOLES

S

S3 SIDES

twA MAX

TY

P

3"

BOLTS PER SCHEDULE

A

6"

1" MAX1/2" MIN

1 1/2" MIN AT STD HOLES

k =

1/2"

MA

X

1 3/

4"

SPAN /4

(2) db

PENETRATIONS

REINFORCED

PENETRATIONS

UNREINFORCED

TYP

db MIN

MIN

(3) db

EQ

EQ

dbMA

X

4"

MA

X

db/2

1/4

1/4

LC

EXTRA STRONG PIPE, LENGTH TO MATCH BEAM FLANGE WIDTH

NO PENETRATIONS

WF BEAM

UNREINFORCED OPENINGREINFORCED OPENING

SUPPORTED BEAM

NOTES:1. COORDINATE BEAM PENETRATION LOCATIONS WITH OTHER DISCIPLINES.2. SUBMIT BEAM PENETRATIONS NOT SPECIFICALLY LOCATED ON THE STRUCTURAL DRAWINGS FOR APPROVAL.

PLATE 3/4 x (bf + 1" MIN)

TYP BEAM SPLICE WHERE REQUIRED

FULL DEPTH 3/8" STIFFENER PLATE EACH SIDE OR FULLDEPTH SHEARPLATE, SEE TYP DETAIL

SIM

ASECTION

INTERIORPERIMETER

1/4TYP

12" MAX

17/32"1 31/32" 2 1/32"

LC

bf

TYP

1/2"

MIN

1 1/

4" T

YP

1" A

T 3

/4"

DIA

BO

LTS

(4) 7/8" DIA TYP(4) 3/4" DIA AT bf ≤ 4 1/2"

STIFFENER PLATE EACH SIDE OF FULL DEPTH SHEAR PLATE

QTY AND SIZE OF STUDSPER SCHEDULE

NOTES:1. SEE BOLTED BEAM CONN SCHEDULE FOR INFO NOT SHOWN.2. hef MIN = 7.5d

COORDINATE WALLREINFORCEMENTW/ STUDS

3/4" PLATE

BOLTS PER BOLTED BEAM CONNECTION SCHEDULE

SHEAR PLATE PER SCHEDULE

[DEFINE]

MEMBER SIZE

STUD, d

6

4

# OF STUDS

ASECTION

1/2" MIN

S

S

1"

3/4"

EQ

EQ

#4 TIE AROUND ANCHORS

EMBED, hef

6"

8"

MINhef/2

MIN

1 1/

2"

MIN1 1/2"

MIN

, TY

Phe

f/2E

QE

Q

[DEFINE]

TYP

1 1/

2"

TYP

3"

1 1/2" MIN

3" MAX

TH

OM

AS

CA

LU

S

16

20

SU

MM

ITR

IDG

E D

RIV

E,

BE

VE

RL

Y H

ILL

S, C

A 9

02

10

SU

D

da

tesh

ee

t title

sh

ee

t nu

mb

er

revis

ion

sclie

nt

dra

wn b

y

da

te

f:e

:31

0. 4

24.5

230

p:31

0.92

9.78

15in

fo@

dom

aen.

net

915

mat

eo s

treet

suite

205

los

ange

les

ca

9002

1

ww

w.d

omae

n.ne

t

EXP 03/31/2019C80463

STATE OF CALIFORN IA

ELIZ

ABE H MAHLOW

REG

IST

ERED

PROFESS IONA L ENGIN

EER

C I V IL

T

600

WIL

SH

IRE

BLV

D, S

UIT

E 7

60LO

S A

NG

ELE

S, C

A 9

0017

213

627

6687

CO

NTA

CT

@N

OU

SE

NG

INE

ER

ING

.CO

M

NOT FOR CONSTRUCTION

TY

PIC

AL

ST

EE

L D

ET

AIL

S -

BE

AM

S &

CO

LUM

NS

S0.

20

AS

P

01/0

4/1

9NOT TO SCALE

BEAM TO BEAM MOMENT CONNECTION7 NOT TO SCALE

BEAM TO BEAM CONNECTION3

NOT TO SCALE

BEAM CONNECTION SCHEDULE13

NOT TO SCALE

STIFFENER CONNECTION PLATE11

NOT TO SCALE

BOLTED BEAM SPLICE8NOT TO SCALE

ROUND HOLE PENETRATION IN BEAM WEB12

NOT TO SCALE

SEATED WF BEAM TO HSS COLUMN14

NOT TO SCALE

BEAM TO CONC WALL EMBED PLATE CONN16

1901

11 S

UD ­

STRU

CTUR

AL P

ROGR

ESS

Page 8: GENERAL NOTES, ABBREVIATIONS, & SHEET LIST · 2019-07-15 · dc -6 wind design: dc dc -1 design criteria dc -2 dc -3 live loads ... scbf special concentrically braced frame sched

2X SOLID BLOCKING FULL-DEPTH OF JOIST AT8'-0" OC OR MID SPAN, WHICHEVER IS LESS

SOLID BLOCKING WHERE PIPING OCCURS

1/2" CLR AROUND PIPE OR CONDUIT

JOIST TYP

d

MIN

d/2

NOTES:1. HOLES & NOTCHES NOT PERMITTED FOR d=5 1/2" OR LESS.2. NOTCHES NOT PERMITTED WITHIN MIDDLE THIRD OF SPAN.3. NOTCHES NOT PERMITTED IN BOTTOM OF MEMBER UNLESS SPECIFICALLY SHOWN ON THE STRUCTURAL DRAWINGS

OR WRITTEN APPROVAL IS OBTAINED FROM THE OWNER'S REPRESENTATIVE.

BEARING WALL

BEAM SUPPORT

LAG SCREW

MAX DIA = d/4 < 2"BEAM OR JOIST

NO NOTCHES OR HOLES PERMITTEDWITHIN d OF SUPPORT

d

MAXd/3

MA

Xd/

6

MIN

d/2

MIN

d

MIN

d

MIN

d MIN

2"

SCREW(4) DIA LAG

MA

Xd/

4

t

TYP4" MAX

1" COUNTERSINK MAX, TYP

TYP1 1/2"

3/4" DIA AUTOMATIC WELDED THREADED STUDS AT 24" OC STAGGERED

2X BLOCKING, TYP

3X RIP TO MATCH FLANGE WIDTH

PROVIDE DOUBLE LINES OF DIAPHRAGM BN

TOFR

NOTE:1. DETAIL SIMILAR FOR DOUBLED UP MEMBERS.

BEARING WALL OR BEAM

PLYWOOD WHEREOCCURS

16d TOE NAIL EACHSIDE INTO TOP PATE

SOLID BLOCKING,END NAIL TO JOISTWITH (2) 16d EACH END

PLYWOODWHEREOCCURS

BUTT JOISTS ON CL OF WALL OR BEAM

CL OF SPLICE & BEARING

(2) SCAB WITH (4) 16dEACH SIDE OF SPLICE

(4) 16d

BEARING WALL OR BEAM

1'-0" MIN 1'-6" MIN

AJOIST LAP

BJOIST BUTT

AT INTERIOR SHEARWALLS, PROVIDE DOUBLE LINES OF DIAPHRAGM BN

NOTES:1. NOTCHING OF MEMBER IS NOT PERMITTED WITHOUT WRITTEN APPROVAL FROM THE OWNER'S REPRESENTATIVE.2. DO NOT PLACE HOLES IN MEMBERS WITH HOLDOWN ANCHORS.3. BORED HOLES SHALL NOT BE LOCATED AT THE SAME SECTION OF STUD AS A NOTCH.

STUDLC

MAX3/8 D

D/2

MIND

D

MAX0.6 D

STUDLC

MAXD/4

D/2

MIND

D

MAXD/3

STUDS ORPOST, TYP

ANON-LOAD BEARING

BLOAD BEARING

D=HOLE DIA

ELEVATION OF PLATE

PLAN OF PLATE

ST2215 EACH SIDE WHERED EXCEEDS W/ 4

ADDITIONALSTUD AT JOIST

STUDS, TYP

JOISTS, TYP16d NAILSDOUBLE PLATE

EQ

EQ

W

D

SUPPORTEDMEMBER

HANGER

SUPPORTING TYPE

NOTES:1. ALL HARDWARE SPECIFIED IS SIMPSON BRAND, UON

NOTES:1. SILL PLATE ANCHOR BOLT TO BE 5/8" DIA WITH 2X2X3/16 PLATE WASHER AND 0'-8" MIN EMBED @ 4'-0" OC, 6" MIN AND 12" MAX

FROM ENDS AND NOTCHES OVER 1/3 THE SILL WIDTH, UON, MIN (2) BOLTS PER PLATE.2. AT NON BEARING WALLS ACCEPTABLE TO REPLACE ANCHOR BOLTS WITH SIMPSON PDPW-300@24" OC(LARR 25469) 6" MAX

FROM ENDS AND NOTCHES PER ABOVE. AT BEARING WALLS USE OF EQUIVALENT SIMPSON PAB ANCHORS AS ALTERNATIVE FOR SILL ANCHORS IS ACCEPTABLE.

3. STUD SIZE AND SPACING TO BE 2X4 @ 16" OC OR 2X6 @ 16" OC, UON.

CRIPPLE:2X AT SPAN < 6'-0"3X AT SPAN > 6'-0"

LINTEL PER SCHEDULE

2-10d EA SIDETYP

3-20d TYP

BLKG

16d @12" OC40d @18" OC AT 3X

2-20d,TYP

DOUBLE TOPPLATE, TYP

A34 BELOWSPLICE, TYP

2-20d END NAIL TYP

A35 @ 6" STUDSA34 @ 4" STUDSPROVIDE AT EA SIDE OF JAMBS

DOUBLE CRIPPLE AND STUDEACH SIDE OF OPENING AT SPAN > 4'-0" AND TRIPLE CRIPPLE ANDSTUD AT SPAN > 8'-0"

(1) 2X (STUD WIDTH) 4'-0" MAX(2) 2X (STUD WIDTH) OVER 4'-0"

2-16d T&B

2-10d EACH SIDE

LINTEL SCHEDULE (UON ON DRAWINGS)

ELEVATION

SEE PLANS

6X8 OR 51/8"X6"GLB

6x6 OR 51/8"X6"GLB

2-2X6OR 4X6

4x8

SPAN < 6'-0"SPAN < 4'-0"SPAN < 3'-0"

2-2X4OR 4X4

3-2X6 OR4X6 FLAT

2X4 STUDS

2X6 STUDS

SPAN OVER 6'-0"

ON STUD CL'S

SPLICE PL'S

SPAN

MA

X 8'

-0"

MA

X 8'

-0"

SILL PLATE ANCHOR BOLT SEE NOTES 1 & 2

(2) 2X TOP PLATES PROVIDE SIMPSON A35 EACH SIDE FOR BEAMS 9 1/4" DEEP AND LARGER

POST OR DOUBLE STUDS PROVIDE 16d @ 12" OC AT DOUBLE STUDS

SHEATHING PER PLAN

BEAM PER PLAN

MIN

1 1/

2"

MAX

3 1/2" 10" MIN 10" MIN

1 1/

2"

NOTCHES MIN 6'-0" OC

TYPICAL 1 1/4" DIA MAX BORED HOLE

1 1/4"X16 GA STRAP W/ (6) 10d COMMON NAILS EACH END AT EACH PLATE

MIN

2 1/

2"

MAX

5 1/2" 1'-0" MIN 1'-0" MIN

MA

X2"

NOTCHES MIN 6'-0" OC

TYPICAL 2" DIA MAX BORED HOLE

1 1/4"X16 GA STRAP W/ (8) 10d COMMON NAILS EACH END AT EACH PLATE

MIN

3 1/

2"

MAX

5 1/2" 1'-0" MIN1'-0" MIN

MA

X3"

NOTCHES MIN 6'-0" OC TYPICAL 2" DIA MAX BORED HOLE

1 1/4"X16 GA STRAP W/ (11) 10d COMMON NAILS EACH END AT EACH PLATE

C2X4 DOUBLE TOP PLATE PLAN

2X4 OR 3X4 SILL PLATE SIMILAR

A2X8 DOUBLE TOP PLATE PLAN

2X8 OR 3X8 SILL PLATE SIMILAR

B2X6 DOUBLE TOP PLATE PLAN

2X6 OR 3X6 SILL PLATE SIMILAR

EN

STITCH NAILING,TYP

EN

STITCH NAILING,TYP

APLAN AT CORNERS

BPLAN AT INTERSECTIONS

ENEN

SILL PLATESSEE SECTIONS AND DETAILS ANCHOR BOLTS NOT SHOWN

POST OR DOUBLE STUDS (PROVIDE 16d AT 12" OC AT DOUBLE STUD

A35 AT OPPOSITE CORNERS FOR 4X POSTSA35 EACH CORNER AT 6X POSTS

TH

OM

AS

CA

LU

S

16

20

SU

MM

ITR

IDG

E D

RIV

E,

BE

VE

RL

Y H

ILL

S, C

A 9

02

10

SU

D

da

tesh

ee

t title

sh

ee

t nu

mb

er

revis

ion

sclie

nt

dra

wn b

y

da

te

f:e

:31

0. 4

24.5

230

p:31

0.92

9.78

15in

fo@

dom

aen.

net

915

mat

eo s

treet

suite

205

los

ange

les

ca

9002

1

ww

w.d

omae

n.ne

t

EXP 03/31/2019C80463

STATE OF CALIFORN IA

ELIZ

ABE H MAHLOW

REG

IST

ERED

PROFESS IONA L ENGIN

EER

C I V IL

T

600

WIL

SH

IRE

BLV

D, S

UIT

E 7

60LO

S A

NG

ELE

S, C

A 9

0017

213

627

6687

CO

NTA

CT

@N

OU

SE

NG

INE

ER

ING

.CO

M

NOT FOR CONSTRUCTION

TY

PIC

AL

WO

OD

DE

TA

ILS

- G

EN

ER

AL

FR

AM

ING

& S

TU

D W

ALL

SS

0.30

AS

P

01/0

4/1

9

NOT TO SCALE

WOOD JOIST BLOCKING1

NOT TO SCALE

HOLES AND NOTCHES IN BEAMS AND JOISTS6 NOT TO SCALE

JOIST PERPENDICULAR TO STEEL BEAMFLUSH

2

NOT TO SCALE

JOIST SPLICE AT BEARING WALLS OR BEAMS3

NOT TO SCALE

HOLES AND NOTCHES IN STUDS OR POSTS7

NOT TO SCALE

HOLES IN PLATES OF WALLS5

NOT TO SCALE

DIMENSION LUMBER HANGER SCHEDULE4

HANGER SCHEDULE

SUPPORTING TYPE SUPPORTING MEMBERSIMPSON HANGER

OPTION

SOLID SAWN 2X BA

SOLID SAWN 2X SKEWED B SKEWED

SOLID SAWN 4X BA

SOLID SAWN 6X8 HU68TF

SOLID SAWN 6X8 SKEWED HW68 SKEWED

SOLID SAWN 6X10 HU610TF

SOLID SAWN 6X10 SKEWED HU610 SKEWED

SOLID SAWN 6X12 HU612TF

SOLID SAWN 6X12 SKEWED HW612 SKEWED

CONCRETE WALL 2X W

CONCRETE WALL 2X SKEWED W SKEWED

NOT TO SCALE

STUD WALL FRAMING10

NOT TO SCALE

FLUSH BEAM PERPENDICULAR TO STUD WALL11

NOT TO SCALE

PENETRATIONS IN TOP OR BOTTOM PLATE14

NOT TO SCALE

STUD WALL CORNERS AND INTERSECTIONS8NOT TO SCALE

POST AND BEAM CONNECTION IN STUD WALL12

1901

11 S

UD ­

STRU

CTUR

AL P

ROGR

ESS

Page 9: GENERAL NOTES, ABBREVIATIONS, & SHEET LIST · 2019-07-15 · dc -6 wind design: dc dc -1 design criteria dc -2 dc -3 live loads ... scbf special concentrically braced frame sched

JOIST OR BLOCKING (SEE PLAN FOR JOIST DIRECTION) FOR LAG SCREWS USE MINIMUM 3X BLOCKING OR RIM JOIST

DOUBLE TOP PLATES,

3X BLOCKING AT ALL ADJOINING

3X STUD AT ALL ADJOINING PANEL EDGES

SHEATHING SEE SCHEDULE

2X STUDS AT 16" OC UNLESS OTHERWISE NOTED

SILL ANCHORPER SCHEDULE

SILL PLATE PER SCHEDULE

1/4" GAP (PLYWOOD TO TOP OF CONCRETE)

ANCHOR ROD, SEE PLAN

NON-SHEAR WALLBEYOND

HOLDOWN POST, PER SCHEDULE

FN PER SCHEDULE

2X STUDS @16" OC

EN PER SCHEDULE

NOTES:1. REFER TO PLAN & SHEAR WALL LEGEND FOR SHEAR WALL TYPE.2. NAILING TO BE 1/2" DISTANCE FROM PANEL EDGE AND 3/8" DISTANCE FROM EDGE OF CONNECTING MEMBERS.3. PLYWOOD JOINT AND SILL NAILING SHALL BE STAGGERED IN ALL CASES.4. WHERE PLYWOOD IS APPLIED TO BOTH FACES OF WALL, STAGGER IN ALL CASES.5. A35 OR LTP4 SHEAR TRANSFER SHALL BE CONNECTING TO PLATE AND BLOCKING, JOIST OR RAFTER. 6. USE OF EQUIVALENT SIMPSON PAB ANCHORS AS ALTERNATIVE FOR SILL ANCHORS IS ACCEPTABLE.

7. PLYWOOD FACE GRAIN TO BE VERTICAL.8. WHERE TOP OF SHEARWALL TERMINATES UNDER STEEL BEAM, SEE 9. WHERE 3X SILL PLATE IS USED, PROVIDE 6" LONG SDS 1/4" SILL PLATE SCREWS.10. ALL WOOD STRUCTURAL PANEL JOINT AND SILL PLATE NAILING SHALL BE STAGGERED AT ALL PANEL EDGES.

SHEAR WALL SCHEDULE

SHEAR WALL TYPE

PLYWOOD PANEL

APA RATED PLYWOOD

(BN)(EN)(FN)

NAILINGSIZE

THK TYPE

ONESIDE

15/32" STRUCT I10d@

6",6",12"

10d@4",4",12"

10d@3", 3",12"

10d@2",2",12"

15/32" STRUCT I

15/32" STRUCT I

15/32" STRUCT I

ONESIDE

ONESIDE

TWOSIDE

5 1/2"

MINSTUD

DEPTH

5 1/2"

5 1/2"

5 1/2"

2X

MINSILLTHK

2X

2X

2X

SILL PLATEANCHOR

TO CONCRETESLAB

SIZE &SPACING

5/8" DIA X8" EMBED @ 24"OC

5/8" DIA X8" EMBED @ 24"OC

5/8" DIA X8" EMBED @ 24"OC

5/8" DIA X8" EMBED @ 24"OC

A35 OR LPT5 FRAMING

CLIPS

AT 12"OCONE SIDE

2 / S0.31

ALLOWSHEAR

PLF

340

510

665

1740

MST48 OVER 4X BLOCKING W/ 16d NAILS

HOLDOWN TO BE OMITTEDWHERE STEEL COLUMN OCCURSAT END OF SHEARWALL

STEEL BEAMWHERE OCCURS

AT 12"OCONE SIDE

AT 8"OCONE SIDE

AT 8"OCTWO SIDES

ALL SILL ANCHORS TO INCLUDE SIMPSON BPS5/8-6 WASHER OR EQUIVALENT AT TOP OF PLATE

15

S0.31

A

B

C

D

NOTES:1. DETAIL SIMILAR AT DOUBLE SIDED SHEATHING.2. SEE SCHEDULES FOR FASTENER INFORMATION.

SHEAR WALL EN

SHEAR WALL EN

2X BLKG WITH (4)16dEND NAIL OR A35EACH SIDE

FRAMING CLIPPER SHEAR WALLSCHEDULE

3X BLKG WITH (4)16dEND NAIL OR A35EACH END

(2) BLKG AT 4'-0" OCTYP

16d @ 4" OCTYP

(2) 16d EACH END, TYP

1"

1"

AJOIST PARALLEL

BJOIST PERPENDICULAR

CJOIST PERPENDICULAR

AT EXTERIOR

PROVIDE DOUBLE LINES OF DIAPHRAGM BN

PROVIDE DOUBLE LINES OF DIAPHRAGM BN

3" M

IN

UONt

e1

ANCHOR ROD WITH DOUBLE NUT AND 3/8" THK X 8" SQ BEARING PLATE

PROVIDE (2) #5 ADDITIONAL BARS X 6'-0" LONG EITHER SIDE OF ANCHOR

PROVIDE (2) #4 U-BARS AT ANCHOR FOR EDGE OF SLAB CONDITION

SILL PLATE

RETIGHTENS NUT AT CLOSE-END OF PROJECT, UPON RETIGHTENS, SECURE W/ DOUBLE NUT

HOLDOWN

POST WIDTH TO MATCH IN WALL

EDGE OF SLAB WHERE OCCURS

FASTENER PER MANUFACTURER

1/4TYP

5'-0"

SHEAR WALL BN

(3) NAILER TO EXTEND LENGTH OF SHEAR WALL

STD WALL NAILING PER GENERAL NOTES

NOTE:1. SEE SCHEDULES FOR FASTENER INFORMATION.

PROVIDE DOUBLE LINES OF DIAPHRAGM BN

8d @ 6"OC

(2) OR (3) WHERESHEAR PANEL OCCURS

(2) OR (3)

HSS COLUMN WITH STUDS PER DETAIL A

(2) TRIMMERPER DETAIL B

BN2X OR 3X

2X TRIMMER W/ #12-24 X 2 1/4"SELF-TAPPING SELF-DRILLINGSCREWS @ 18" OC AND 6" FROM EACH END TYP

HSS COLUMN W/ STUD PER DETAIL A

2X OR 3X

HSS COLUMNEN

3/4"DIA AUTOMATIC WELDED THREADED STUDS @ 24" OC AND 6" FROM EACH END TYP

AHSS COLUMN

BHSS COLUMN

CHSS COLUMN

WALLAND POSTLC

WALLAND POSTLC

WALLAND POSTLC

WF COLUMN W/ STUDS PER DETAIL A

BN (NAIL SHEATHING TO 3X NAILER PRIOR TO ATTACHING TO STEEL IN THE EVENT OF LIMITED ACCESS)

3X

DWF COLUMN

BNBN

TH

OM

AS

CA

LU

S

16

20

SU

MM

ITR

IDG

E D

RIV

E,

BE

VE

RL

Y H

ILL

S, C

A 9

02

10

SU

D

da

tesh

ee

t title

sh

ee

t nu

mb

er

revis

ion

sclie

nt

dra

wn b

y

da

te

f:e

:31

0. 4

24.5

230

p:31

0.92

9.78

15in

fo@

dom

aen.

net

915

mat

eo s

treet

suite

205

los

ange

les

ca

9002

1

ww

w.d

omae

n.ne

t

EXP 03/31/2019C80463

STATE OF CALIFORN IA

ELIZ

ABE H MAHLOW

REG

IST

ERED

PROFESS IONA L ENGIN

EER

C I V IL

T

600

WIL

SH

IRE

BLV

D, S

UIT

E 7

60LO

S A

NG

ELE

S, C

A 9

0017

213

627

6687

CO

NTA

CT

@N

OU

SE

NG

INE

ER

ING

.CO

M

NOT FOR CONSTRUCTION

TY

PIC

AL

WO

OD

DE

TA

ILS

- S

HE

AR

WA

LLS

S0.

31

AS

P

01/0

4/1

9

NOT TO SCALE

SHEAR WALL SCHEDULE AND ELEVATION11NOT TO SCALE

SHEAR WALL SECTION15

NOT TO SCALE

SHEAR WALL HOLDOWN AT SUSPENDED SLAB4NOT TO SCALE

SHEAR WALL BELOW STEEL BEAM2NOT TO SCALE

SHEAR WALL STEEL COLUMN CONNECTION16

1901

11 S

UD ­

STRU

CTUR

AL P

ROGR

ESS

Page 10: GENERAL NOTES, ABBREVIATIONS, & SHEET LIST · 2019-07-15 · dc -6 wind design: dc dc -1 design criteria dc -2 dc -3 live loads ... scbf special concentrically braced frame sched

BN

EDGE OF ROOF/FLOORAND/OR EXTERIOR WALL BELOW

JOISTS OR RAFTERS

BLOCKING

A

C

NOTES: 1. PROVIDE WOOD STRUCTURAL PANEL SHEETS NOT LESS THAN 2'-0" IN LEAST DIMENSION NOR LESS THAN 8'-0" SQ FEET IN

AREA. USE FULL SHEETS WHEREVER POSSIBLE.2. PLACE WOOD STRUCTURAL PANEL SHEET WITH FACE PLIES PERPENDICULAR TO JOISTS AND STAGGER 4'-0" EDGES AS

SHOWN.3. COORDINATE JOIST LAYOUT WITH 4'-0" MODULE AS RELATED TO STRUCTURAL 1 RATED SHEATHING EXPOSURE 1. 4. ADHESIVE: ADHESIVE SHALL CONFORM TO APA SPECIFICATION AFG-01 OR ASTM D3498, APPLIED IN ACCORDANCE WITH THE

ADHESIVE MANUFACTURER'S RECOMMENDATIONS. IF OSB PANELS WITH SEALED SURFACES AND EDGES ARE TO BE USED, USE ONLY SOLVENT-BASED GLUES; CHECK WITH PANEL MANUFACTURER. EXECUTION:

B

* NAILING TO BE RING OR SPIRAL SHANK, FULL HEAD.

A. APPLY A BEAD OF GLUE ABOUT 1/4 INCH IN DIA TO ALL CONTACT/BEARING SURFACES. ON WIDE AREAS APPLY GLUE IN SERPENTINE PATTERN.

B. APPLY TWO BEADS OF GLUE ON JOISTS WHERE PANEL ENDS BUTT.C. APPLY GLUE PROGRESSIVELY TO BUTTING EDGES OF PANELS AND INTO GROOVED EDGES OF

TONGUE AND GROOVE PANELS AS WORK PROCEEDS. COMPLETE NAILING OF EACH PANEL BEFORE GLUE SETS.

5. AT INTERIOR SHEARWALL LOCATIONS, PROVIDE DOUBLE LINES OF DIAPHRAGM NAILING INTO TRANSFER BLOCKING OR TOP PLATES.

3X4 FLAT BLOCKING W/Z-SHAPED SHEET METAL CLIPS WITH 4-NAILS EACH END

LC

EQEQ

EN

BUTT WOOD STRUCTURAL PANEL SHEETS ALONG CL OF BLOCKING

GLUE BUTTINGEDGES PERADHESIVE NOTE

CSECTION AT BLOCKING

PROVIDE GLUE PER ADHESIVE NOTE AT FLOOR SHEATHING LOCATIONS

SHEATHINGPER SCHEDULE

EN, FOR SIZE ANDSPACING SEE NOTES

FIELD NAILING AT ALL INTERMEDIATE JOISTS, TYP SEE NOTES FOR SPACING

APLAN VIEW

BUTT WOOD STRUCTURAL PANELSHEETS ALONG CL OF SUPPORTS

EN, TWO LINES OF FASTENERS REQUIRED PER SCHEDULE

BUTT WOOD STRUCTURAL PANELSHEETS ALONG CL OF SUPPORTS

BPLAN VIEW - HIGH

STRENGTH DIAPH

NA

ILE

D F

AC

E

3/8"

TY

PA

T 3"

NO

MIN

AL

FASTENER SPACING

NA

ILE

D F

AC

E

1/2"

TY

PA

T 3"

NO

MIN

AL

JOISTS OR RAFTERS

BLOCKING

NA

ILE

D F

AC

E

WID

TH

OF

NA

ILE

D F

AC

E

1/2"

TY

PA

T 4"

NO

MIN

AL

NA

ILE

D F

AC

E

3/4"

TY

PA

T 4"

NO

MIN

AL

SEE ARCH FOR OPENING LOCATIONDOUBLE JOIST TYP

3X BLOCKING

ST22, TYP

LUS48, TYP

4X8

4X8

4X8

4X8

NOTE:1. EDGE NAIL AROUND OPENING.

MARK TYPE

S1

S2

S3

S4

CMST12

NOTES:1. ALL STRAPS ARE SIMPSON BRAND (LARR 25713).2. NAILS INDICATED ARE MINIMUM NUMBER OF NAILS REQUIRED IN MINIMUM END LENGTH DISTANCE SHOWN

ABOVE.3. REFER TO PLAN FOR REQUIRED LENGTH OF STRAPS. WHERE NO LENGTH IS INDICATED ON PLANS, STRAP

LENGTH SHALL EQUAL TWICE THE MINIMUM END LENGTH DISTANCE SHOWN IN SCHEDULE ABOVE.4. WHERE LENGTH OF STRAP IS LONGER THAN MINIMUM END LENGTH SHOWN ABOVE, PROVIDE FULL NAILING

OVER ENTIRE LENGTH OF STRAP.5. FULL NAILING IS EQUIVALENT NAILING REQUIRED OVER MINIMUM END LENGTH DISTANCE SHOWN ABOVE.

CMST14

CS14

DETAIL

-

-

-

-

S5

CS16

CS18

LENGTH

PER PLAN

PER PLAN

PER PLAN

PER PLAN

PER PLAN

NAILS

(86) 10d

(66) 10d

(30) 8d

(22) 8d

(18) 8d

MIN ENDLENGTH

39"

30"

16"

13"

11"

ALLOWABLELOAD

9215#

6490#

2490#

1705#

1370# -

STRAP SCHEDULE

3D PLAN JOIST PER PLAN

FIELD NAILING (FN)

CONTINUOUS EDGE NAILING (EN) PROVIDE 2X BLOCKING PER DETAIL A AT BLOCKED DIAPHRAGM

DISCONTINOUS EDGE NAILING (EN)

BOUNDARY NAILING (BN)BOUNDARY NAILING (BN)

PLYWOOD SHEATHING PER PLAN

2'-0" MINSTAGGER END JOINTS

4'-0" TYP

TH

OM

AS

CA

LU

S

16

20

SU

MM

ITR

IDG

E D

RIV

E,

BE

VE

RL

Y H

ILL

S, C

A 9

02

10

SU

D

da

tesh

ee

t title

sh

ee

t nu

mb

er

revis

ion

sclie

nt

dra

wn b

y

da

te

f:e

:31

0. 4

24.5

230

p:31

0.92

9.78

15in

fo@

dom

aen.

net

915

mat

eo s

treet

suite

205

los

ange

les

ca

9002

1

ww

w.d

omae

n.ne

t

EXP 03/31/2019C80463

STATE OF CALIFORN IA

ELIZ

ABE H MAHLOW

REG

IST

ERED

PROFESS IONA L ENGIN

EER

C I V IL

T

600

WIL

SH

IRE

BLV

D, S

UIT

E 7

60LO

S A

NG

ELE

S, C

A 9

0017

213

627

6687

CO

NTA

CT

@N

OU

SE

NG

INE

ER

ING

.CO

M

NOT FOR CONSTRUCTION

TY

PIC

AL

WO

OD

DE

TA

ILS

- H

OR

IZO

NT

AL

DIA

PH

RA

GM

SS

0.32

AS

P

01/0

4/1

9NOT TO SCALE

DIAPHRAGM SHEATHING SCHEDULE7

NOT TO SCALE

OPENING IN ROOF8 NOT TO SCALE

STRAP SCHEDULE4

DIAPHRAGM SHEATHING SCHEDULE

DIAPHTYPE

SHEATHING

NAILING

DETAILLINES OFFASTENERS

TYPE*WIDTH OF

NAILED FACEBN EN FN

D115/32" DFLSTRUCT I

1 10d COMMON 2" 4" 6" 12" A

D223/32" DFLSTRUCT I

2 10d COMMON 3" 2 1/2" 3" 12" B

1901

11 S

UD ­

STRU

CTUR

AL P

ROGR

ESS

Page 11: GENERAL NOTES, ABBREVIATIONS, & SHEET LIST · 2019-07-15 · dc -6 wind design: dc dc -1 design criteria dc -2 dc -3 live loads ... scbf special concentrically braced frame sched

S S

2

3

A

1

BCDEFGHI

4

5

6

7

PROPERTY LINE, TYP

10"

10" 10" 1

'-0"

10"

10"

10"

24" MAT

FOUNDATION

BELOW WALLS

10"

GB-3

GB-2

GB-2

GB-1

GB-1

SEE S2 SERIES

FOR HOUSE FRAMING

GB-4

RETAINING WALL PLAN LEGEND

INDICATES STEP IN FOOTING PER

INDICATES REINFORCED CONCRETE WALL ABOVE

THICKNESS PER PLAN

FOR TYPICAL REINFORCING INFORMATION

SEE SCHEDULE

1. TOP OF FOOTING GRADE BEAM ELEVATION TO BE 1'-0" BELOW TOP OF SLAB OR FINISHED GRADE, UON.

2. REFER TO S0 SERIES SHEETS FOR GENERAL NOTES AND TYPICAL DETAILS.

3. ALL SETTING OUT DIMENSIONS ARE TO BE READ IN CONJUNCTION AND CONFIRMED WITH ARCHITECTURAL

DRAWINGS.

4. PRIOR TO REQUESTING A BUILDING DEPARMENT FOUNDATION INSPECTION, THE SOILS

ENGINEER/GEOTECHNICAL CONSULTANT SHALL INSPECT AND IMPROVE THE FOUNDATION EXCAVATIONS.

5. EXCAVATIONS SHALL BE MADE AS NEAR AS POSSIBLE TO THE NEAT LINES REQUIRED BY THE SIZE AND

SHAPE OF THE STRUCTURE. NO MATERIAL IS TO BE EXCAVATED UNNECESSARILY.

6. VERIFY LOCATION OF UNDERGROUND UTILITIES BEFORE EXCAVATIONS. NOTIFY ARCHITECT PRIOR TO

EXCAVATION IN THE EVENT SUCH UTILITIES ARE ENCOUNTERED.

RETAINING WALL PLAN NOTES

INDICATES FRICTION PILE PER SCHEDULE

AND DETAIL

P#

8 / S0.11

3 / S0.11

TH

OM

AS

CA

LU

S

16

20

SU

MM

ITR

IDG

E D

RIV

E,

BE

VE

RL

Y H

ILL

S, C

A 9

02

10

SU

D

da

tesh

ee

t title

sh

ee

t nu

mb

er

revis

ion

sclie

nt

dra

wn b

y

da

te

f:e

:31

0. 4

24.5

230

p:31

0.92

9.78

15in

fo@

dom

aen.

net

915

mat

eo s

treet

suite

205

los

ange

les

ca

9002

1

ww

w.d

omae

n.ne

t

EXP 03/31/2019C80463

STATE OF CALIFORN IA

ELIZ

ABE H MAHLOW

REG

IST

ERED

PROFESS IONA L ENGIN

EER

C I V IL

T

600

WIL

SH

IRE

BLV

D, S

UIT

E 7

60LO

S A

NG

ELE

S, C

A 9

0017

213

627

6687

CO

NTA

CT

@N

OU

SE

NG

INE

ER

ING

.CO

M

NOT FOR CONSTRUCTION

RE

TA

ININ

G W

ALL

PLA

NS

1.00

Aut

hor

01/0

4/1

9

1/8" = 1'-0"

RETAINING WALL PLAN1

FRICTION PILE SCHEDULE

TYPE

MARKDIA LENGTH OF PILE, L

EMBED DEPTH IN

BEDROCK, D

ASSUMED DEPTH

OF FILL, FVERTICAL BARS SPIRAL/TIE SIZE

SPIRAL/TIE

SPACING

P1 2'-0" 15'-0" 15'-0" 0"

P2 2'-0" 15'-0" 15'-0" 0"

P3 2'-0" 15'-0" 15'-0" 0"

P4 2'-0" 15'-0" 15'-0" 0"

P5 2'-0" 15'-0" 15'-0" 0"

P6 2'-0" 15'-0" 15'-0" 0"

P7 2'-0" 15'-0" 15'-0" 0"

P8 2'-0" 15'-0" 15'-0" 0"

P9 2'-0" 15'-0" 15'-0" 0"

P10 2'-0" 15'-0" 15'-0" 0"

P11 2'-0" 15'-0" 15'-0" 0"

P12 2'-0" 15'-0" 15'-0" 0"

P13 2'-0" 15'-0" 15'-0" 0"

P14 2'-0" 15'-0" 15'-0" 0"

P17 2'-0" 15'-0" 15'-0" 0"

P19 2'-0" 15'-0" 15'-0" 0"

P20 2'-0" 15'-0" 15'-0" 0"

P21 2'-0" 15'-0" 15'-0" 0"

P22 2'-0" 15'-0" 15'-0" 0"

P23 2'-0" 15'-0" 15'-0" 0"

P24 2'-0" 15'-0" 15'-0" 0"

P25 2'-0" 15'-0" 15'-0" 0"

P26 2'-0" 15'-0" 15'-0" 0"

P27 2'-0" 15'-0" 15'-0" 0"

P28 2'-0" 15'-0" 15'-0" 0"

P29 2'-0" 15'-0" 15'-0" 0"

P30 2'-0" 15'-0" 15'-0" 0"

P31 2'-0" 15'-0" 15'-0" 0"

P32 2'-0" 15'-0" 15'-0" 0"

P33 2'-0" 15'-0" 15'-0" 0"

P34 2'-0" 15'-0" 15'-0" 0"

P35 2'-0" 15'-0" 15'-0" 0"

P36 2'-0" 15'-0" 15'-0" 0"

REINFORCED CONCRETE WALL SCHEDULE

TYPEWALL THICKNESS VERTICAL REINFORCEMENT HORIZONTAL REINFORCEMENT

BOUNDARY ZONE

REINFORCEMENT

BOUNDARY ZONE

LENGTH, LBZ

RC 8" 8"

RC 10" 10"

RC 12" 12"

GRADE BEAM SCHEDULE

TYPE MARK WIDTH, W DEPTH, D

LONGITUDINAL REINFORCEMENTTRANSVERSE

REINFORCEMENT

TOP BARS BOTTOM BARSTIES

ADDITIONAL

TIEST1 T2 B1 B2

GB-1 3' - 0" 2'-0"

GB-2 2' - 0" 2'-0"

GB-3 3' - 6" 2'-0"

GB-4 4' - 8" 2'-0"

1901

11 S

UD ­

STRU

CTUR

AL P

ROGR

ESS

Page 12: GENERAL NOTES, ABBREVIATIONS, & SHEET LIST · 2019-07-15 · dc -6 wind design: dc dc -1 design criteria dc -2 dc -3 live loads ... scbf special concentrically braced frame sched

S S

2

3

A

1

BCDEFGHI

4

5

6

7

2

S3.00

1

S3.02

1

S3.00

1

S3.01

2

S3.01

10"

12"

8"

8"

8"

10"

8"

8"

8"

10"

8"

12"

10"

10"

10"

TOC: 1001'-3 3/4"

GB

-2

GB

-2

GB-1

P1

P17

GB

-3

C1

C1

GB-1

24" MAT FOUNDATION

BELOW WALLS

8"

S4.00

6

10

S3.10

9

S5.00

2

S3.02

10" 10"

10"

CF

-1

GB-2

8"

S3.10

5

10" THK STRUCTURAL SLAB

10"

P20P21P22 P19 P4 P3

P2

10" THK STRUCTURAL SLAB

SEE S2.00R FOR

REINFORCEMENT PLAN

TOC: 1001'-3 3/4"

TOC: 999'-9 1/2" 10"

CF

-1

7

S0.11

CF

-1

CF

-1

SHORING PILES

UNDER SEPARATE PERMIT

10" THK STRUCTURAL SLAB

SEE S2.00R FOR

REINFORCEMENT PLAN P23

3'-0

"

4'-7

"

P24

P25 P26

P30 P29P31

GB

-3

GB-3

GB-3

GB-2 GB-2GB-2

GB-3

CF

-2

CF

-1

GB-1

10

S5.00

11

S5.00

14

S0.11

P27

P28

P32

P33

GB

-1G

B-1

GB

-2

GB-2

P34

P35

P36

FOUNDATION PLAN LEGEND

INDICATES STEP IN FOOTING PER

INDICATES REINFORCED CONCRETE WALL ABOVE

THICKNESS PER PLAN

FOR TYPICAL REINFORCING INFORMATION

SEE SCHEDULE

1. TOP OF FOOTING GRADE BEAM ELEVATION TO BE 1'-0" BELOW TOP OF SLAB OR FINISHED GRADE, UON.

2. REFER TO S0 SERIES SHEETS FOR GENERAL NOTES AND TYPICAL DETAILS.

3. ALL SETTING OUT DIMENSIONS ARE TO BE READ IN CONJUNCTION AND CONFIRMED WITH ARCHITECTURAL

DRAWINGS.

4. PRIOR TO REQUESTING A BUILDING DEPARMENT FOUNDATION INSPECTION, THE SOILS

ENGINEER/GEOTECHNICAL CONSULTANT SHALL INSPECT AND IMPROVE THE FOUNDATION EXCAVATIONS.

5. EXCAVATIONS SHALL BE MADE AS NEAR AS POSSIBLE TO THE NEAT LINES REQUIRED BY THE SIZE AND

SHAPE OF THE STRUCTURE. NO MATERIAL IS TO BE EXCAVATED UNNECESSARILY.

6. CURBS AND DEPRESSIONS ARE SHOWN FOR REFERENCE ONLY. SEE ARCH DWGS FOR LOCATIONS,

HEIGHT, AND THICKNESS.

7. SEE ARCH DWGS FOR EDGE OF SLAB LOCATIONS.

8. VERIFY LOCATION OF UNDERGROUND UTILITIES BEFORE EXCAVATIONS. NOTIFY ARCHITECT PRIOR TO

EXCAVATION IN THE EVENT SUCH UTILITIES ARE ENCOUNTERED.

9. FOR DRAINAGE DETAILS, SUMPS, PITS, DAMP PROOFING, TRENCHES, CURBS, EXTERIOR WALKS, UTILITIES,

EQUIPMENT DETAILS, STEPS, ETC., SEE DRAWINGS OTHER THAN STRUCTURAL.

10. SLAB CONSTRUCTION AND CONTROL JOINT LOCATIONS SHALL BE APPROVED BY THE ARCHITECT PRIOR TO

PLACING ANY CONCRETE.

11. PROVIDE A 6" CURB AT EXTERIOR TIMBER WALLS. SEE ARCHITECTURAL DRAWINGS FOR LOCATIONS.

FOUNDATION PLAN NOTES

INDICATES SHOTCRETE WALL ABOVE

THICKNESS PER PLAN

FOR TYPICAL REINFORCING INFORMATION

SEE SCHEDULE

INDICATES FRICTION PILE PER SCHEDULE

AND DETAIL

P#

8 / S0.11

3 / S0.11

3/16" = 1'-0"

BASEMENT FOUNDATION PLAN1

TH

OM

AS

CA

LU

S

16

20

SU

MM

ITR

IDG

E D

RIV

E,

BE

VE

RL

Y H

ILL

S, C

A 9

02

10

SU

D

da

tesh

ee

t title

sh

ee

t nu

mb

er

revis

ion

sclie

nt

dra

wn b

y

da

te

f:e

:31

0. 4

24.5

230

p:31

0.92

9.78

15in

fo@

dom

aen.

net

915

mat

eo s

treet

suite

205

los

ange

les

ca

9002

1

ww

w.d

omae

n.ne

t

EXP 03/31/2019C80463

STATE OF CALIFORN IA

ELIZ

ABE H MAHLOW

REG

IST

ERED

PROFESS IONA L ENGIN

EER

C I V IL

T

600

WIL

SH

IRE

BLV

D, S

UIT

E 7

60LO

S A

NG

ELE

S, C

A 9

0017

213

627

6687

CO

NTA

CT

@N

OU

SE

NG

INE

ER

ING

.CO

M

NOT FOR CONSTRUCTION

BA

SE

ME

NT

FO

UN

DA

TIO

N P

LAN

S2.

00

JR01/0

4/1

9

REINFORCED CONCRETE WALL SCHEDULE

TYPEWALL THICKNESS VERTICAL REINFORCEMENT HORIZONTAL REINFORCEMENT

BOUNDARY ZONE

REINFORCEMENT

BOUNDARY ZONE

LENGTH, LBZ

RC 8" 8"

RC 10" 10"

RC 12" 12"

GRADE BEAM SCHEDULE

TYPE MARK WIDTH, W DEPTH, D

LONGITUDINAL REINFORCEMENTTRANSVERSE

REINFORCEMENT

TOP BARS BOTTOM BARSTIES

ADDITIONAL

TIEST1 T2 B1 B2

GB-1 3' - 0" 2'-0"

GB-2 2' - 0" 2'-0"

GB-3 3' - 6" 2'-0"

GB-4 4' - 8" 2'-0"

CONTINUOUS FOOTING SCHEDULE

TYPE

MARKWIDTH, W DEPTH, D TOP BARS BOTTOM BARS SIDE BARS TIES

CF-1 3' - 0" 2'-0" -

CF-2 5' - 0" 2'-0" -

STEEL COLUMN SCHEDULE

TYPE MARK COLUMN TYPEBASE PLATE DIMENSIONS ANCHOR RODS TOP CONNECTION

DETAIL

BASE CONNECTION

DETAILB N t MARK EMBED

C1 HSS6X6X1/2

C2 HSS4X4X1/2

C3 HSS4X8X1/2

FRICTION PILE SCHEDULE

TYPE MARK DIALENGTH OF PILE,

LVERTICAL BARS SPIRAL/TIE SIZE

SPIRAL/TIE

SPACING

P1 2'-0" 15'-0"

P2 2'-0" 15'-0"

P3 2'-0" 15'-0"

P4 2'-0" 15'-0"

P5 2'-0" 15'-0"

P6 2'-0" 15'-0"

P7 2'-0" 15'-0"

P8 2'-0" 15'-0"

P9 2'-0" 15'-0"

P10 2'-0" 15'-0"

P11 2'-0" 15'-0"

P12 2'-0" 15'-0"

P13 2'-0" 15'-0"

P14 2'-0" 15'-0"

P17 2'-0" 15'-0"

P19 2'-0" 15'-0"

P20 2'-0" 15'-0"

P21 2'-0" 15'-0"

P22 2'-0" 15'-0"

P23 2'-0" 15'-0"

P24 2'-0" 15'-0"

P25 2'-0" 15'-0"

P26 2'-0" 15'-0"

P27 2'-0" 15'-0"

P28 2'-0" 15'-0"

P29 2'-0" 15'-0"

P30 2'-0" 15'-0"

P31 2'-0" 15'-0"

P32 2'-0" 15'-0"

P33 2'-0" 15'-0"

P34 2'-0" 15'-0"

P35 2'-0" 15'-0"

P36 2'-0" 15'-0"

1901

11 S

UD ­

STRU

CTUR

AL P

ROGR

ESS

DOES SLAB EXTENDHERE?

DETERMINE IF CONCRETEWALL AT SHORING PILESWILL BE SHOTCRETE

CONFIRM FINISHMATERIAL ANDTHICKNESS. TOP OFCOCNRETE TO BEOFFSET HOW FARBELOW FINISH FLOOR?TYP ALL FLOORS

Page 13: GENERAL NOTES, ABBREVIATIONS, & SHEET LIST · 2019-07-15 · dc -6 wind design: dc dc -1 design criteria dc -2 dc -3 live loads ... scbf special concentrically braced frame sched

2

3

A

1

BCDEFGHI

4

5

6

7

2

S3.00

1

S3.02

1

S3.00

1

S3.01

2

S3.01

10"

8" 8" 8"

8" 8"8"

10"

10"

TOC: 1011'-7 3/4"

TOC: 1011'-1 3/4"

C1

C3

C3

C1

C1

10"

8"

10

S3.10

2

S3.02

GB-4

BE

LOW

8"

HSS8X3X1/2

HS

S8X

3X1/

2

HSS6X2X1/8 @ 6" OC

HS

S8X

3X1/

2

HSS8X

3X1/

2

HS

S8X

3X1/

2

HS

S8X

3X1/

2

HS

S8X

3X1/

2HSS6X2X1/8 @ 6" OC HSS6X2X1/8 @ 6" OCHSS6X2X1/8 @ 6" OCHSS6X2X1/8 @ 6" OC

POOL INSERT BY OTHERSUNDER SEPARATE PERMIT

S4.00

8

8"

1012'-1 3/4" 1012'-1 3/4"

GB

-3

TOW: 1015'-5 3/4"

TOW: 1015'-5 3/4"

10" THK STRUCTURAL SLAB SEE S2.01R FOR

REINFORCEMENT PLAN

1011'-1 3/4"

TOC:

10" THK STRUCTURAL SLAB SEE S2.01R FOR

REINFORCMENT PLAN

10" THK STRUCTURAL SLAB SEE S2.01R FOR

REINFORCMENT PLAN

10" THK STRUCTURAL SLAB SEE S2.01R FOR

REINFORCMENT PLAN

FRAMING PLAN LEGEND

INDICATES STUD WALL PER ARCH

INDICATES WALL BELOW

INDICATES REINFORCED CONCRETE WALL ABOVETHICKNESS PER PLANFOR TYPICAL REINFORCING INFORMATIONSEE SCHEDULE

INDICATES STEEL COLUMN TYPEFOR ADDITIONAL INFORMATION REFER TO SCHEDULE

C#

1. TOP OF CONCRETE PER PLAN (TOC).2. TOP OF CONCRETE BEAMS ARE FLUSH AND OCCUR IMMEDIATELY BELOW METAL DECK, UON.3. REFER TO S0 SERIES SHEETS FOR GENERAL NOTES AND TYPICAL DETAILS.4. DEPRESSIONS, CURBS, AND OPENINGS SHOWN ON THIS PLAN ARE NOT COMPLETE AS TO NUMBER, SIZE,

AND LOCATION. FOR COMPLETE INFORMATION, REFER TO DRAWINGS OTHER THAN STRUCTURAL.5. GENERAL CONTRACTOR SHALL COORDINATE THE LOCATION OF EQUIPMENT SUPPORT BEAMS AND BEAMS

AROUND FLOOR OPENINGS WITH ALL PROJECT REQUIREMENTS.6. EDGE OF SLAB LOCATIONS ARE APPROXIMATE, SEE ARCH DWGS FOR EDGE OF SLAB DIMENSIONS.

FRAMING PLAN NOTES

INDICATES SHOTCRETE WALL ABOVETHICKNESS PER PLANFOR TYPICAL REINFORCING INFORMATIONSEE SCHEDULE

INDICATES STUD/BEARING WALL PERTHICKNESS AND LOCATION PER ARCH

10 / S0.30

INDICATES SLOPED FOUNDATIONUP

INDICATES STEP IN DIAPHRAGM PER

TH

OM

AS

CA

LU

S

16

20

SU

MM

ITR

IDG

E D

RIV

E,

BE

VE

RL

Y H

ILL

S, C

A 9

02

10

SU

D

da

tesh

ee

t title

sh

ee

t nu

mb

er

revis

ion

sclie

nt

dra

wn b

y

da

te

f:e

:31

0. 4

24.5

230

p:31

0.92

9.78

15in

fo@

dom

aen.

net

915

mat

eo s

treet

suite

205

los

ange

les

ca

9002

1

ww

w.d

omae

n.ne

t

EXP 03/31/2019C80463

STATE OF CALIFORN IA

ELIZ

ABE H MAHLOW

REG

IST

ERED

PROFESS IONA L ENGIN

EER

C I V IL

T

600

WIL

SH

IRE

BLV

D, S

UIT

E 7

60LO

S A

NG

ELE

S, C

A 9

0017

213

627

6687

CO

NTA

CT

@N

OU

SE

NG

INE

ER

ING

.CO

M

NOT FOR CONSTRUCTION

MA

IN L

EV

EL

FR

AM

ING

PLA

NS

2.01

JR01/0

4/1

9

3/16" = 1'-0"

MAIN LEVEL FRAMING PLAN1

STEEL COLUMN SCHEDULE

TYPE MARK COLUMN TYPEBASE PLATE DIMENSIONS ANCHOR RODS TOP CONNECTION

DETAILBASE CONNECTION

DETAILB N t MARK EMBED

C1 HSS6X6X1/2

C2 HSS4X4X1/2

C3 HSS4X8X1/2

REINFORCED CONCRETE WALL SCHEDULE

TYPEWALL THICKNESS VERTICAL REINFORCEMENT HORIZONTAL REINFORCEMENT

BOUNDARY ZONEREINFORCEMENT

BOUNDARY ZONELENGTH, LBZ

RC 8" 8"

RC 10" 10"

RC 12" 12"

GRADE BEAM SCHEDULE

TYPE MARK WIDTH, W DEPTH, D

LONGITUDINAL REINFORCEMENTTRANSVERSE

REINFORCEMENT

TOP BARS BOTTOM BARSTIES

ADDITIONALTIEST1 T2 B1 B2

GB-1 3' - 0" 2'-0"

GB-2 2' - 0" 2'-0"

GB-3 3' - 6" 2'-0"

GB-4 4' - 8" 2'-0"

1901

11 S

UD ­

STRU

CTUR

AL P

ROGR

ESS

NOTE: WALL BELOWDASHED GRAPHICS TOBE UPDATED

NOTE: WALL BELOWDASHED GRAPHICS TOBE UPDATED

PARTIAL HEIGHT WALLSTO BE CLARIFIED.

CONFIRM IF ANY SLABON GRADE OR WALLSREQUIRED

NOTE: SLAB EXTENDEDTO SUPPORT TRELLISCOLUMN. VERIFY SITE FRAMINGNEEDED.

CONFIRM FINISHMATERIAL ANDTHICKNESS. TOP OFCOCNRETE TO BEOFFSET HOW FARBELOW FINISH FLOOR?TYP ALL FLOORS

CONFIRM WE AREADDING FRAMINGCORRECTLY.

CONFIRM STEP IN SLABLOCATIONS ­ PROVIDEDIMENSION ORBACKGROUND TOMATCH SECTION

THICKNESS TO BEVERIFIED FORPOSSIBLE REDUCTION

Page 14: GENERAL NOTES, ABBREVIATIONS, & SHEET LIST · 2019-07-15 · dc -6 wind design: dc dc -1 design criteria dc -2 dc -3 live loads ... scbf special concentrically braced frame sched

2

3

A

1

BCDEFGHI

4

5

6

7

2

S3.00

1

S3.02

1

S3.00

1

S3.01

2

S3.01

10"

TH

K S

TR

UC

TU

RA

L S

LAB

BE

LOW

PE

R S

3.01

TOC: 1011'-7 3/4"

TOC: 1011'-1 3/4"

10

S3.10

2

S3.02

TOC: 1007'-1 3/4"

(5) #5 @ 12T x 6'-0"

NUMBER OF ADDITIONAL BARS

BAR SIZE

BAR SPACING (@ 12 = 12" OC)

BAR LOCATION

BAR LENGTH, SEE DETAILS FOR ADD'L REQUIREMENTS

ADD'L REINFORCING LEGEND:

1. SEE FRAMING PLAN FOR THE TOP OF CONCRETE SLAB ELEVATION AND THICKNESS.2. SLAB TO HAVE A CONTINUOUS MESH OF T&B REINFORCEMENT. SEE TYPICAL DETAILS

FOR REBAR PLACEMENT INFORMATION.3. ADD'L REINFORCEMENT TO BE CENTERED ON COLUMN UON.

4. ADD'L REINFORCEMENT TO BE DISTRIBUTED EVENLY ACROSS EXTENTS AS INDICATED.5. FOR LOCATIONS WHERE REINFORCING AT OPENINGS CANNOT BE EXTENDED BEYOND

EDGE TO PROVIDE REQUIRED TENSION DEVELOPMENT, PROVIDE HOOKED BARS.6. ADD'L REINFORCING TO BE PROVIDED AS FOLLOWS:

REINFORCEMENT PLAN NOTES:

REINFORCEMENT ORIENTATION:

Y

X

T1, B1

T2,

B2

INSIDE LAYER, T1

OUTSIDE LAYER, T2

INSIDE LAYER, B1

OUTSIDE LAYER, B2

PLAN SECTION

TH

OM

AS

CA

LU

S

16

20

SU

MM

ITR

IDG

E D

RIV

E,

BE

VE

RL

Y H

ILL

S, C

A 9

02

10

SU

D

da

tesh

ee

t title

sh

ee

t nu

mb

er

revis

ion

sclie

nt

dra

wn b

y

da

te

f:e

:31

0. 4

24.5

230

p:31

0.92

9.78

15in

fo@

dom

aen.

net

915

mat

eo s

treet

suite

205

los

ange

les

ca

9002

1

ww

w.d

omae

n.ne

t

EXP 03/31/2019C80463

STATE OF CALIFORN IA

ELIZ

ABE H MAHLOW

REG

IST

ERED

PROFESS IONA L ENGIN

EER

C I V IL

T

600

WIL

SH

IRE

BLV

D, S

UIT

E 7

60LO

S A

NG

ELE

S, C

A 9

0017

213

627

6687

CO

NTA

CT

@N

OU

SE

NG

INE

ER

ING

.CO

M

NOT FOR CONSTRUCTION

MA

IN L

EV

EL

RE

INF

OR

CE

ME

NT

PLA

NS

2.01

R

JR01/0

4/1

9

3/16" = 1'-0"

MAIN LEVEL REINFORCEMENT PLAN1

1901

11 S

UD ­

STRU

CTUR

AL P

ROGR

ESS

IN PROGRESS

Page 15: GENERAL NOTES, ABBREVIATIONS, & SHEET LIST · 2019-07-15 · dc -6 wind design: dc dc -1 design criteria dc -2 dc -3 live loads ... scbf special concentrically braced frame sched

VITREO US CHINALAVATO RYLADENAK-2215VITREO US CHINALAVATO RYLADENAK-2215

2

3

A

1

BCDEFGHI

4

5

6

7

2

S3.00

1

S3.02

1

S3.00

1

S3.01

C8X11.5

8"

8"

8"

8" TYP

SW1.5

SW1.4

SW

1.2

SW

1.3

SW

1.1 10" THK STRUCTURAL SLAB

SEE S2.02R FORREINFORCEMENT PLAN

TOC: 1024'-0 1/4"

C2

HDU-8

6x6

HDU-8

6x6

HDU-8

6x6

HDU-8

6x6

HDU-8

6x6

HDU-8

6x6HDU-8

6x6

HDU-8

6x6

C2

HSS8X3X1/2

HSS8X3X1/2

HSS8X3X1/2

HSS4X2X1/8

HS

S8X

3X1/

2

HS

S8X

3X1/

2

HS

S8X

3X1/

2

EQ EQH

SS

8X3X

1/2

10

S3.10

10"

10"

1

S5.00

5

S5.00

6

S5.00

2

S5.00

3

S5.00

2

S3.02

HSS8X3X1/2

HSS8X3X1/2

HS

S8X

3X1/

2

HSS8X3X1/2

HSS8X3X1/2

HSS6X2X1/8 @ 6" OC

HSS6X2X1/8 @ 6" OC

HSS4X2X1/8 @ 6" OCHSS4X2X1/8 @ 6" OCHSS4X2X1/8 @ 6" OC

HSS4X2X1/8 @ 6" OC

HSS4X2X1/8 @ 6" OC

10" THK STRUCTURAL SLABSEE S2.02R FOR

REINFORCEMENT PLAN

TOC: 1024'-0 1/4"

10" THK STRUCTURAL SLABSEE S2.02R FOR

REINFORCEMENT PLAN

RA

MP

UP

TOW: 1024'-0 1/4"

10" THK STRUCTURAL SLAB AT BASE OF WALL

OPEN TO BELOW

8" THK STRUCTURAL SLABSEE S2.02R FOR

REINFORCEMENT PLAN

TOC: 1023'-10 1/4"

S3.10

7

TOC: 1024'-0 1/4"

8" THK STRUCTURAL SLABSEE S2.02R FOR

REINFORCEMENT PLAN

10"

C2

SW

1.6

SW1.7C2

SW1.1

INDICATES WOOD SHEAR WALL EXTENTS, ABOVELENGTH SHOWN IN SCHEDULE INDICATES APPROXIMATE LENGTH OF SHEAR WALL, ACTUAL LENGTH MAY DEVIATE +/- 6".

INDICATES WOOD SHEAR WALL ID, AT SIDE TO BE NAILEDREFER TO "SHEAR WALL SCHEDULE" FOR ADDITIONAL INFORMATION• FOR SHEAR WALL CONSTRUCTION PER "SHEAR WALL TYPE"

REFER TO

INDICATES LOCATION OF POST AND HOLDOWN, • POST SIZE PER PLAN• HOLDOWN TYPE PER PLAN• ADDITIONAL HOLDOWN, ANCHOR ROD, AND EMBED

INFORMATION PER "HOLDOWN SCHEDULE" AND DETAIL

HDU86x6

HDU86x6

11 / S0.31

4 / S0.31

FRAMING PLAN LEGEND

INDICATES STUD WALL PER ARCH SEE

INDICATES WALL BELOW

INDICATES REINFORCED CONCRETE WALL ABOVETHICKNESS PER PLANFOR TYPICAL REINFORCING INFORMATIONSEE SCHEDULE

INDICATES STEEL COLUMN TYPEFOR ADDITIONAL INFORMATION REFER TO SCHEDULE

C#

1. TOP OF CONCRETE PER PLAN (TOC).2. TOP OF CONCRETE BEAMS ARE FLUSH AND OCCUR IMMEDIATELY BELOW METAL DECK, UON.3. REFER TO S0 SERIES SHEETS FOR GENERAL NOTES AND TYPICAL DETAILS.4. DEPRESSIONS, CURBS, AND OPENINGS SHOWN ON THIS PLAN ARE NOT COMPLETE AS TO NUMBER, SIZE,

AND LOCATION. FOR COMPLETE INFORMATION, REFER TO DRAWINGS OTHER THAN STRUCTURAL.5. GENERAL CONTRACTOR SHALL COORDINATE THE LOCATION OF EQUIPMENT SUPPORT BEAMS AND BEAMS

AROUND FLOOR OPENINGS WITH ALL PROJECT REQUIREMENTS.6. EDGE OF SLAB LOCATIONS ARE APPROXIMATE, SEE ARCH DWGS FOR EDGE OF SLAB DIMENSIONS.

FRAMING PLAN NOTES

10 / S0.30

INDICATES SLOPED FOUNDATIONUP

TH

OM

AS

CA

LU

S

16

20

SU

MM

ITR

IDG

E D

RIV

E,

BE

VE

RL

Y H

ILL

S, C

A 9

02

10

SU

D

da

tesh

ee

t title

sh

ee

t nu

mb

er

revis

ion

sclie

nt

dra

wn b

y

da

te

f:e

:31

0. 4

24.5

230

p:31

0.92

9.78

15in

fo@

dom

aen.

net

915

mat

eo s

treet

suite

205

los

ange

les

ca

9002

1

ww

w.d

omae

n.ne

t

EXP 03/31/2019C80463

STATE OF CALIFORN IA

ELIZ

ABE H MAHLOW

REG

IST

ERED

PROFESS IONA L ENGIN

EER

C I V IL

T

600

WIL

SH

IRE

BLV

D, S

UIT

E 7

60LO

S A

NG

ELE

S, C

A 9

0017

213

627

6687

CO

NTA

CT

@N

OU

SE

NG

INE

ER

ING

.CO

M

NOT FOR CONSTRUCTION

UP

PE

R L

EV

EL

FR

AM

ING

PLA

NS

2.02

JR01/0

4/1

9

3/16" = 1'-0"

UPPER LEVEL FRAMING PLAN1

WOOD SHEAR WALL SCHEDULE

WALL ID SHEAR WALL TYPE LENGTH WIDTH

SW1.1 8'-0" 5 1/2"

SW1.2 7'-0" 5 1/2"

SW1.3 11'-0" 5 1/2"

SW1.4 23'-0" 5 1/2"

SW1.5 24'-0" 5 1/2"

SW1.6 3'-6" 5 1/2"

SW1.7 26'-0" 5 1/2"

HOLDOWN SCHEDULE

TYPE MIN POST SIZE, t FOUNDATION EMBED, e SLAB EMBED, e1ANCHOR ROD

DIAMETERWOOD

FASTENER

HDU-8 5 1/2" 0"

STEEL COLUMN SCHEDULE

TYPE MARK COLUMN TYPEBASE PLATE DIMENSIONS ANCHOR RODS TOP CONNECTION

DETAILBASE CONNECTION

DETAILB N t MARK EMBED

C1 HSS6X6X1/2

C2 HSS4X4X1/2

C3 HSS4X8X1/2

REINFORCED CONCRETE WALL SCHEDULE

TYPEWALL THICKNESS VERTICAL REINFORCEMENT HORIZONTAL REINFORCEMENT

BOUNDARY ZONEREINFORCEMENT

BOUNDARY ZONELENGTH, LBZ

RC 8" 8"

RC 10" 10"

RC 12" 12"

1901

11 S

UD ­

STRU

CTUR

AL P

ROGR

ESS

CONFIRM STEP IN SLABLOCATIONS ­ PROVIDEDIMENSION ORBACKGROUND TOMATCH SECTION

CONFIRM IFSTRUCTURAL SLABSHOULD SLOPE, ORTOPPING SLOPE ONLY

PLEASE VERIFY THISASSUMPTION BASEDON SECTIONS

Page 16: GENERAL NOTES, ABBREVIATIONS, & SHEET LIST · 2019-07-15 · dc -6 wind design: dc dc -1 design criteria dc -2 dc -3 live loads ... scbf special concentrically braced frame sched

2

3

A

1

BCDEFGHI

4

5

6

7

2

S3.00

1

S3.02

1

S3.00

1

S3.01

10" THK STRUCTURAL SLABSEE S2.02R FOR

REINFORCEMENT PLAN

TOC: 1024'-0 1/4"

10

S3.10

1

S5.00

5

S5.00

6

S5.00

2

S5.00

3

S5.00

2

S3.02

(5) #5 @ 12T x 6'-0"

NUMBER OF ADDITIONAL BARS

BAR SIZE

BAR SPACING (@ 12 = 12" OC)

BAR LOCATION

BAR LENGTH, SEE DETAILS FOR ADD'L REQUIREMENTS

ADD'L REINFORCING LEGEND:

1. SEE FRAMING PLAN FOR THE TOP OF CONCRETE SLAB ELEVATION AND THICKNESS.2. SLAB TO HAVE A CONTINUOUS MESH OF T&B REINFORCEMENT. SEE TYPICAL DETAILS

FOR REBAR PLACEMENT INFORMATION.3. ADD'L REINFORCEMENT TO BE CENTERED ON COLUMN UON.

4. ADD'L REINFORCEMENT TO BE DISTRIBUTED EVENLY ACROSS EXTENTS AS INDICATED.5. FOR LOCATIONS WHERE REINFORCING AT OPENINGS CANNOT BE EXTENDED BEYOND

EDGE TO PROVIDE REQUIRED TENSION DEVELOPMENT, PROVIDE HOOKED BARS.6. ADD'L REINFORCING TO BE PROVIDED AS FOLLOWS:

REINFORCEMENT PLAN NOTES:

REINFORCEMENT ORIENTATION:

Y

X

T1, B1

T2,

B2

INSIDE LAYER, T1

OUTSIDE LAYER, T2

INSIDE LAYER, B1

OUTSIDE LAYER, B2

PLAN SECTION

TH

OM

AS

CA

LU

S

16

20

SU

MM

ITR

IDG

E D

RIV

E,

BE

VE

RL

Y H

ILL

S, C

A 9

02

10

SU

D

da

tesh

ee

t title

sh

ee

t nu

mb

er

revis

ion

sclie

nt

dra

wn b

y

da

te

f:e

:31

0. 4

24.5

230

p:31

0.92

9.78

15in

fo@

dom

aen.

net

915

mat

eo s

treet

suite

205

los

ange

les

ca

9002

1

ww

w.d

omae

n.ne

t

EXP 03/31/2019C80463

STATE OF CALIFORN IA

ELIZ

ABE H MAHLOW

REG

IST

ERED

PROFESS IONA L ENGIN

EER

C I V IL

T

600

WIL

SH

IRE

BLV

D, S

UIT

E 7

60LO

S A

NG

ELE

S, C

A 9

0017

213

627

6687

CO

NTA

CT

@N

OU

SE

NG

INE

ER

ING

.CO

M

NOT FOR CONSTRUCTION

UP

PE

R L

EV

EL

RE

INF

OR

CE

ME

NT

PLA

NS

2.02

R

JR01/0

4/1

9

3/16" = 1'-0"

UPPER LEVEL REINFORCEMENT PLAN1

1901

11 S

UD ­

STRU

CTUR

AL P

ROGR

ESS

IN PROGRESS

Page 17: GENERAL NOTES, ABBREVIATIONS, & SHEET LIST · 2019-07-15 · dc -6 wind design: dc dc -1 design criteria dc -2 dc -3 live loads ... scbf special concentrically braced frame sched

S1X6

S1X6

S1X6

S1X6

S1X6

S1X6 S1X6S1X6

S1X6

S1X6

2

3

A

1

BCDEFGHI

4

5

6

7

2

S3.00

1

S3.02

1

S3.00

1

S3.01

HS

S4X

4X1/

2

HS

S4X

4X1/

2

HS

S4X

4X1/

2

HS

S8X

3X1/

2

HSS4X2X1/8

W8X21

W8X

21

W8X

21

W8X

21

PSL3.5X11.875

W8X

21[+

0'-5

"]

4X12

4X12

HS

S4X

4X1/

2

W8X21

2

S3.02

D1

TOD: 1034'-4 3/4"

D1TOD: 1032'-10 11/16"

J1 J1 J1

J1

HSS4X2X1/8 @ 6" OC HSS4X2X1/8 @ 6" OC HSS4X2X1/8 @ 6" OC

HSS4X2X1/8 @ 6" OC

HS

S4X

4X1/

2

HSS4X2X1/8

HSS4X2X1/8 @ 6" OCHSS4X2X1/8 @ 6" OC

S5.00

8

7

S5.00

4

S5.00

J2

W8X35

WALL STEPSWALL STEPS

TOW: 1032'-9 7/32"

PSL3.5X11.875

W8X21 W8X21

4X12

W8X35

W8X

35

J1 J1

4X12 4X12

4X12

FRAMING PLAN LEGEND

INDICATES WALL BELOW

1. TOP OF FRAMING PER PLAN (TOFR). SHEATHING ABOVE TOP OF FRAMING.2. REFER TO STEEL BEAM LEGEND FOR NAILER CONDITION. TOP OF FRAMING INCLUDES

NAILER THICKNESS.3. REFER TO S0 SERIES SHEETS FOR GENERAL NOTES AND TYPICAL DETAILS.4. DEPRESSIONS, CURBS, AND OPENINGS SHOWN ON THIS PLAN ARE NOT COMPLETE AS TO

NUMBER, SIZE, AND LOCATION. FOR COMPLETE INFORMATION, REFER TO DRAWINGS OTHER

THAN STRUCTURAL.5. GENERAL CONTRACTOR SHALL COORDINATE THE LOCATION OF EQUIPMENT SUPPORT

BEAMS AND BEAMS AROUND FLOOR OPENINGS WITH ALL PROJECT REQUIREMENTS.6. EDGE OF SLAB LOCATIONS ARE APPROXIMATE, SEE ARCH DWGS FOR EDGE OF SLAB

DIMENSIONS.

FRAMING PLAN NOTES

INDICATES STEP IN DIAPHRAGM PER

J1 INDICATES JOIST TYPE PER SCHEDULEEXTENT PER PLANFOR HANGER INFORMATION SEE

INDICATES DIAPHRAGM TYPE, FOR ADDITIONAL INFORMATION REFER TO

D#

INDICATES STRAP PER SCHEDULE

INDICATES TOTAL STRAP LENGTH (FT)

W18x40

SIZE

INDICATES STEEL CANTILEVER, NON-MOMENT FRAME CONNECTION

STEEL BEAM LEGEND

[-1 1/2"]

DEVIATION OF TOS FROM TOFR

TH

OM

AS

CA

LU

S

16

20

SU

MM

ITR

IDG

E D

RIV

E,

BE

VE

RL

Y H

ILL

S, C

A 9

02

10

SU

D

da

tesh

ee

t title

sh

ee

t nu

mb

er

revis

ion

sclie

nt

dra

wn b

y

da

te

f:e

:31

0. 4

24.5

230

p:31

0.92

9.78

15in

fo@

dom

aen.

net

915

mat

eo s

treet

suite

205

los

ange

les

ca

9002

1

ww

w.d

omae

n.ne

t

EXP 03/31/2019C80463

STATE OF CALIFORN IA

ELIZ

ABE H MAHLOW

REG

IST

ERED

PROFESS IONA L ENGIN

EER

C I V IL

T

600

WIL

SH

IRE

BLV

D, S

UIT

E 7

60LO

S A

NG

ELE

S, C

A 9

0017

213

627

6687

CO

NTA

CT

@N

OU

SE

NG

INE

ER

ING

.CO

M

NOT FOR CONSTRUCTION

RO

OF

FR

AM

ING

PLA

NS

2.03

JR01/0

4/1

9

3/16" = 1'-0"

ROOF LEVEL FRAMING PLAN1

JOIST SCHEDULE

TYPE MARKSIZE ANDSPACING

HANGER(TYPICAL)

HANGER(SKEWED)

NOTES

J1 2X12 @ 16" OC

J2 2X10 @ 16" OC

1901

11 S

UD ­

STRU

CTUR

AL P

ROGR

ESS

IS WALL INTENDED TOSTOP AT LOW ROOF,OR CAN WALLCONTINUE TO HIGH?

IF WALL STOPS LOW,WE WILL USE KINGPOSTS TO SUPPORTHIGH ROOF.

TRELLIS FRAMING TOEXTEND BACK TOSTEEL FRAMINGBEYOND ROLER SHADE

DBL JOISTS SHAPED TOFIT THINNER ROOF

Page 18: GENERAL NOTES, ABBREVIATIONS, & SHEET LIST · 2019-07-15 · dc -6 wind design: dc dc -1 design criteria dc -2 dc -3 live loads ... scbf special concentrically braced frame sched

MAIN LEVEL T.O.C.1012'-1 3/4"

UPPER LEVEL T.O.C.1024'-0 1/4"

ROOF LEVEL T.O.D.1034'-4 3/4"

2 3

BASEMENT T.O.C.1001'-3 3/4"

1 4 5 6 7

T.O.F.989'-3 3/4"

APPROX LINE OF

BEDROCK PER SOILS

REPORT

MAIN LEVEL T.O.C.1012'-1 3/4"

UPPER LEVEL T.O.C.1024'-0 1/4"

ROOF LEVEL T.O.D.1034'-4 3/4"

2 3

BASEMENT T.O.C.1001'-3 3/4"

1 4 5 6 7

T.O.F.989'-3 3/4"

APPROX LINE OF

BEDROCK PER SOILS

REPORT

TH

OM

AS

CA

LU

S

16

20

SU

MM

ITR

IDG

E D

RIV

E,

BE

VE

RL

Y H

ILL

S, C

A 9

02

10

SU

D

da

tesh

ee

t title

sh

ee

t nu

mb

er

revis

ion

sclie

nt

dra

wn b

y

da

te

f:e

:31

0. 4

24.5

230

p:31

0.92

9.78

15in

fo@

dom

aen.

net

915

mat

eo s

treet

suite

205

los

ange

les

ca

9002

1

ww

w.d

omae

n.ne

t

EXP 03/31/2019C80463

STATE OF CALIFORN IA

ELIZ

ABE H MAHLOW

REG

IST

ERED

PROFESS IONA L ENGIN

EER

C I V IL

T

600

WIL

SH

IRE

BLV

D, S

UIT

E 7

60LO

S A

NG

ELE

S, C

A 9

0017

213

627

6687

CO

NTA

CT

@N

OU

SE

NG

INE

ER

ING

.CO

M

NOT FOR CONSTRUCTION

BU

ILD

ING

SE

CT

ION

SS

3.00

Aut

hor

01/0

4/1

9

1/8" = 1'-0"

BUILDING SECTION1 1/8" = 1'-0"

BUILDING SECTION2

1901

11 S

UD ­

STRU

CTUR

AL P

ROGR

ESS

DOUBLE JOISTS TOFRAME EDGE OF ROOF

TRELLIS FRAMING WILLBE DESIGNED TOMATCH ARCHBACKGROUNDS,VERIFY BACKGROUNDSIZE AND SPACING ISINTENT OR, IF UPDATESARE REQUIRED

WALL TO EXTEND TOLOWER SLAB.VERIFY TROUGH ANDSLAB FRAMING IS OKTO PROCEED WITHCALCULATIONS

NOTE: ALL PILES INPROGRESS.EMBEDMENT TO BECHECKED FORLOADING AND H/3SETBACK

SOLDIER PILE WALLPER SOILS REPORT. CONFIRM FINISHGRADE/ EXISTING WALLIN FRONT TO REMAIN.WILL YOU BEMODELING THESE FORUS TO REFRENCE?

Page 19: GENERAL NOTES, ABBREVIATIONS, & SHEET LIST · 2019-07-15 · dc -6 wind design: dc dc -1 design criteria dc -2 dc -3 live loads ... scbf special concentrically braced frame sched

MAIN LEVEL T.O.C.1012'-1 3/4"

UPPER LEVEL T.O.C.1024'-0 1/4"

ROOF LEVEL T.O.D.1034'-4 3/4"

A

BASEMENT T.O.C.1001'-3 3/4"

BCDEFGHI

APPROX LINE OF

BEDROCK PER SOILS

REPORT

MAIN LEVEL T.O.C.1012'-1 3/4"

A

BASEMENT T.O.C.1001'-3 3/4"

BCDEFGHI

T.O.F.989'-3 3/4"

TOC: 1007'-1 3/4"

APPROX LINE OF

BEDROCK PER SOILS

REPORT

TH

OM

AS

CA

LU

S

16

20

SU

MM

ITR

IDG

E D

RIV

E,

BE

VE

RL

Y H

ILL

S, C

A 9

02

10

SU

D

da

tesh

ee

t title

sh

ee

t nu

mb

er

revis

ion

sclie

nt

dra

wn b

y

da

te

f:e

:31

0. 4

24.5

230

p:31

0.92

9.78

15in

fo@

dom

aen.

net

915

mat

eo s

treet

suite

205

los

ange

les

ca

9002

1

ww

w.d

omae

n.ne

t

EXP 03/31/2019C80463

STATE OF CALIFORN IA

ELIZ

ABE H MAHLOW

REG

IST

ERED

PROFESS IONA L ENGIN

EER

C I V IL

T

600

WIL

SH

IRE

BLV

D, S

UIT

E 7

60LO

S A

NG

ELE

S, C

A 9

0017

213

627

6687

CO

NTA

CT

@N

OU

SE

NG

INE

ER

ING

.CO

M

NOT FOR CONSTRUCTION

BU

ILD

ING

SE

CT

ION

SS

3.01

Aut

hor

01/0

4/1

9

1/8" = 1'-0"

BUILDING SECTION1

1/8" = 1'-0"

BUILDING SECTION2

1901

11 S

UD ­

STRU

CTUR

AL P

ROGR

ESS

NOTE: RHINO MODELLINKED IN PINK FORADDITIONALREFERENCE. WHERE RHINO ANDCAD CONFLICT, RHINOIS TURNED OFF ANDCAD IS FOLLOWED.

WE REMOVED WALLSHERE AS IT SEEMSTHEY ARE NOT NEEDEDTO RETAIN ANYTHING?SLAB ABOVE SPANSBETWEEN PILES

Page 20: GENERAL NOTES, ABBREVIATIONS, & SHEET LIST · 2019-07-15 · dc -6 wind design: dc dc -1 design criteria dc -2 dc -3 live loads ... scbf special concentrically braced frame sched

MAIN LEVEL T.O.C.1012'-1 3/4"

UPPER LEVEL T.O.C.1024'-0 1/4"

ROOF LEVEL T.O.D.1034'-4 3/4"

2 3

BASEMENT T.O.C.1001'-3 3/4"

1 4 5 6 7

T.O.F.989'-3 3/4"

APPROX LINE OF

BEDROCK PER SOILS

REPORT

MAIN LEVEL T.O.C.1012'-1 3/4"

UPPER LEVEL T.O.C.1024'-0 1/4"

ROOF LEVEL T.O.D.1034'-4 3/4"

2 3

BASEMENT T.O.C.1001'-3 3/4"

1 4 5 6 7

T.O.F.989'-3 3/4"

APPROX LINE OF

BEDROCK PER SOILS

REPORT

TH

OM

AS

CA

LU

S

16

20

SU

MM

ITR

IDG

E D

RIV

E,

BE

VE

RL

Y H

ILL

S, C

A 9

02

10

SU

D

da

tesh

ee

t title

sh

ee

t nu

mb

er

revis

ion

sclie

nt

dra

wn b

y

da

te

f:e

:31

0. 4

24.5

230

p:31

0.92

9.78

15in

fo@

dom

aen.

net

915

mat

eo s

treet

suite

205

los

ange

les

ca

9002

1

ww

w.d

omae

n.ne

t

EXP 03/31/2019C80463

STATE OF CALIFORN IA

ELIZ

ABE H MAHLOW

REG

IST

ERED

PROFESS IONA L ENGIN

EER

C I V IL

T

600

WIL

SH

IRE

BLV

D, S

UIT

E 7

60LO

S A

NG

ELE

S, C

A 9

0017

213

627

6687

CO

NTA

CT

@N

OU

SE

NG

INE

ER

ING

.CO

M

NOT FOR CONSTRUCTION

BU

ILD

ING

SE

CT

ION

SS

3.02

Aut

hor

01/0

4/1

9

1/8" = 1'-0"

BUILDING SECTION1 1/8" = 1'-0"

BUILDING SECTION2

1901

11 S

UD ­

STRU

CTUR

AL P

ROGR

ESS

Page 21: GENERAL NOTES, ABBREVIATIONS, & SHEET LIST · 2019-07-15 · dc -6 wind design: dc dc -1 design criteria dc -2 dc -3 live loads ... scbf special concentrically braced frame sched

2

EF

10

S3.10

3

DE

4

14

S3.10

MAIN LEVEL T.O.C.1012'-1 3/4"

UPPER LEVEL T.O.C.1024'-0 1/4"

BASEMENT T.O.C.1001'-3 3/4"

EF

6

S5.00

MAIN LEVEL T.O.C.1012'-1 3/4"

UPPER LEVEL T.O.C.1024'-0 1/4"

3

BASEMENT T.O.C.1001'-3 3/4"

4

TH

OM

AS

CA

LU

S

16

20

SU

MM

ITR

IDG

E D

RIV

E,

BE

VE

RL

Y H

ILL

S, C

A 9

02

10

SU

D

da

tesh

ee

t title

sh

ee

t nu

mb

er

revis

ion

sclie

nt

dra

wn b

y

da

te

f:e

:31

0. 4

24.5

230

p:31

0.92

9.78

15in

fo@

dom

aen.

net

915

mat

eo s

treet

suite

205

los

ange

les

ca

9002

1

ww

w.d

omae

n.ne

t

EXP 03/31/2019C80463

STATE OF CALIFORN IA

ELIZ

ABE H MAHLOW

REG

IST

ERED

PROFESS IONA L ENGIN

EER

C I V IL

T

600

WIL

SH

IRE

BLV

D, S

UIT

E 7

60LO

S A

NG

ELE

S, C

A 9

0017

213

627

6687

CO

NTA

CT

@N

OU

SE

NG

INE

ER

ING

.CO

M

NOT FOR CONSTRUCTION

ST

AIR

PLA

NS

AN

D D

ET

AIL

SS

3.10

Aut

hor

01/0

4/1

9

1/4" = 1'-0"

ENLARGED STAIR PLAN AT BASEMENT LEVEL5

1/4" = 1'-0"

ENLARGED STAIR PLAN AT UPPER LEVEL7

1/4" = 1'-0"

STAIR SECTION10 1/4" = 1'-0"

STAIR SECTION14

1901

11 S

UD ­

STRU

CTUR

AL P

ROGR

ESS

IN PROGRESS

Page 22: GENERAL NOTES, ABBREVIATIONS, & SHEET LIST · 2019-07-15 · dc -6 wind design: dc dc -1 design criteria dc -2 dc -3 live loads ... scbf special concentrically braced frame sched

EFGHI

5

6

AROUND POOL

10" TYP

12

S4.00

10" THK STRUCTURAL SLABW/ #5 @ 12" OC EA WAY

TOP AND BOTTOM

16

S4.00

14

S4.00

EFGHI

5

6

12

S4.00

16

S4.00

14

S4.00

TOW: 1012'-1 3/4"

TOW: 1012'-1 3/4"

TOW: 1012'-1 3/4"

10" THK STRUCTURAL SLABSEE MAIN BUILDING PLANS

MAIN LEVEL T.O.C.1012'-1 3/4"

BASEMENT T.O.C.1001'-3 3/4"

5 6

T.O.F.989'-3 3/4"

MAIN LEVEL T.O.C.1012'-1 3/4"

BASEMENT T.O.C.1001'-3 3/4"

5 6

MAIN LEVEL T.O.C.1012'-1 3/4"

BASEMENT T.O.C.1001'-3 3/4"

EFGHI

TH

OM

AS

CA

LU

S

16

20

SU

MM

ITR

IDG

E D

RIV

E,

BE

VE

RL

Y H

ILL

S, C

A 9

02

10

SU

D

da

tesh

ee

t title

sh

ee

t nu

mb

er

revis

ion

sclie

nt

dra

wn b

y

da

te

f:e

:31

0. 4

24.5

230

p:31

0.92

9.78

15in

fo@

dom

aen.

net

915

mat

eo s

treet

suite

205

los

ange

les

ca

9002

1

ww

w.d

omae

n.ne

t

EXP 03/31/2019C80463

STATE OF CALIFORN IA

ELIZ

ABE H MAHLOW

REG

IST

ERED

PROFESS IONA L ENGIN

EER

C I V IL

T

600

WIL

SH

IRE

BLV

D, S

UIT

E 7

60LO

S A

NG

ELE

S, C

A 9

0017

213

627

6687

CO

NTA

CT

@N

OU

SE

NG

INE

ER

ING

.CO

M

NOT FOR CONSTRUCTION

PO

OL

PLA

NS

AN

D S

EC

TIO

NS

S4.

00

Aut

hor

01/0

4/1

9

1/4" = 1'-0"

POOL PLAN AT BASEMENT LEVEL6

1/4" = 1'-0"

POOL PLAN AT MAIN LEVEL8 1/4" = 1'-0"

POOL SECTION16 1/4" = 1'-0"

POOL SECTION12

1/4" = 1'-0"

POOL SECTION14

1901

11 S

UD ­

STRU

CTUR

AL P

ROGR

ESS

IN PROGRESS. TO REVIEW FRAMING LOCATION

AND REQUIREMENTS AROUND POOL.

Page 23: GENERAL NOTES, ABBREVIATIONS, & SHEET LIST · 2019-07-15 · dc -6 wind design: dc dc -1 design criteria dc -2 dc -3 live loads ... scbf special concentrically braced frame sched

SH-IO

SH-IO1

SH-IO2

SH-IO3

SHORING - STRUCTURAL TESTS, INSPECTIONS, & OBSERVATIONS

SEE SO SERIES SECTION IO FOR ADDITIONAL STRUCTURAL TEST, INSPECTIONS, & OBSERVATION NOTES.

MONITOR THE LATERAL MOVEMENT OF SOLDIER PILE TO THE NEAREST 0.01 FOOT. THE MOVEMENT SHALL BE OBSERVED WEEKLY AT THE TOP OF THE SOLDIER PILE UNLESS OTHERWISE DIRECTED. SUBMIT THE RESULTS TO THE

SHORING ENGINEER WITHIN 24 HOURS OF THE READINGS.

THE SHORING DESIGN ENGINEER SHALL MAKE PERIODIC INSPECTIONS OF THE JOB SITE FOR THE PURPOSE OF OBSERVING THE INSTALLATION OF SHORING SYSTEM AND MONITORING OF SURVEY.

SH

SH-1

SH-2

SH-3

SH-4

SH-5

SH-6

SH-7

SH-8

SH-9

SHORING - RETAINING WALL GENERAL NOTES

REFER TO GENERAL NOTES ON S0.00 AND S0.01 WHICH APPLY TO SHORING, UON.

THE WORK INCLUDES THE CONSTRUCTION OF SOLDIER PILES AND LAGGING.

THE SHORING SYSTEM IS DESIGNED FOR ENVELOPE CONDITION OF TEMPORARY AND PERMANENT CONSTRUCTION

LOADING. THE SHORING PILES WILL BE INTEGRATED INTO THE PERMANENT RETAINING WALL.

EXCAVATION SHALL BE CONDUCTED IN SUCH A MANNER AS TO PREVENT CAVING OF BANKS AND LOSS OF GROUND, EXCAVATION SHALL BE DONE IN STEPS, BEING COORDINATED WITH THE INSTALLATION OF THE LAGGING AS OUTLINED UNDER PROCEDURES.

THE DESIGN IS BASED ON ANTICIPATED SOIL CONDITIONS ON THE BASIS OF THE BORINGS AND SOIL REPORT PREPARED BY IRVINE GEOTECHNICAL. IF THE ACTUAL FIELD CONDITIONS VARY FROM THE ASSUMED CONDITIONS, ADJUSTMENTS WILL BE MADE AT THE DIRECTION OF THE GEOTECHNICAL ENGINEER AND THE SHORING ENGINEER.

THE CONTRACTOR SHALL TAKE PRECAUTIONS DURING THE EXCAVATION TO MINIMIZE OVERBREAK OF EXISTING ROCK.

THE CONTRACTOR SHALL COMPLY WITH ALL CONSTRUCTION SAFETY ORDERS AND TRENCH CONSTRUCTION SAFETY ORDERS OF THE STATE OF CALIFORNIA AND FEDERAL LAWS.

THE CONTRACTOR SHALL COMPLY WITH REQUIREMENTS REGARDING THE INSPECTION, PROTECTION AND REPAIR OF UNDERGROUND UTILITIES.

BACKFILL IN ACCORDANCE WITH THE PROJECT SPECIFICATIONS AND THE GEOTECHNICAL REPORT.

SH-CC

SH-CC1

SH-CC2

SH-CC3

SH-CC4

SHORING - CAST IN PLACE CONCRETE

SEE S0 SERIES SECTION CC FOR ADDITIONAL CAST IN PLACE CONCRETE NOTES.

ALL CONCRETE FOR SHORING SHALL BE STRUCTURAL CONCRETE UNLESS OTHERWISE NOTED. STRUCTURAL CONCRETE SHALL BE NORMAL WEIGHT CONCRETE, SHALL CONTAIN A MINIMUM OF SIX SACKS OF CEMENT PER CUBIC YARD, AND SHALL DEVELOP A MINIMUM 7-DAY COMPRESSIVE STRENGTH OF 4,000 PSI UN0.

LEAN CONCRETE FILL SHALL PROVIDE STABLE SUPPORT TO THE GROUND. LEAN CONCRETE FILL SHALL CONTAIN A MINIMUM OF 1-1/2 SACKS OF CEMENT PER CUBIC YARD OF CONCRETE.

THE CONCRETE IN SHORING CAISSONS SHALL BE PLACED THROUGH A RIGID TREMIE OR PUMP PIPE LOCATED WITHIN ONE FOOT OF THE BOTTOM OF THE CAISSON AT THE BEGINNING OF CONCRETING AND MAINTAINED A MINIMUM OF 5 FEET AND A MAXIMUM OF 10 FEET BELOW THE SURFACE OF THE CONCRETE THEREAFTER.

SH-L

SH-L1

SH-L2

SHORING - LAGGING

WHERE SPECIFIED, WOOD LAGGING SHALL BE USED. WOOD LAGGING SHALL BE ROUGH DOUGLAS FIR (COAST REGION) CONST., GRADED, INSPECTED AND APPROVED BY THE WEST COAST LUMBER INSPECTION BUREAU OR THE WESTERN WOOD PRODUCTS ASSOCIATION. LUMBER SHALL BE PRESSURE TREATED WITH ALKALINE COPPER QUAT (ACQ), AMMONIACAL COPPER ZINC ARSENATE (ACZA), OR AMMONIACAL COPPER ARSENATE (ACA) IN ACCORDANCE WITH THE "STANDARD FOR PRESERVATIVE TREATMENT BY PRESSURE PROCESSES - ALL TIMBER PRODUCTS" OF THE

AMERICAN WOOD PRESERVERS BUREAU. MINIMUM RETENTION SHALL BE 0.4 POUNDS PER CUBIC FOOT OR REFUSAL. FIELD CUT SURFACES SHALL BE TREATED WITH ACQ, ACZA, OR ACA SOLUTION. WOOD COMPONENTS SHALL NOT BE USED FOR PERMANENT SHORING LASTING MORE THAN 2YRS.

WOOD COMPONENTS OF THE TEMPORARY SHORING THAT MAY AFFECT THE PERFORMANCE OF THE PERMANENT STRUCTURE SHALL BE REMOVED AFTER SHORING IS NO LONGER REQUIRED.

SH-U

SH-U1

SH-U2

SH-U3

SH-U4

SH-U5

SH-U6

SH-U7

SHORING - SUBMITTALS

IN ADDITION TO SUBMITTALS SPECIFIED IN THE PROJECT GENERAL NOTES, PROVIDE THE FOLLOWING SHOP DRAWINGS FOR ALL STRUCTURAL STEEL, REINFORCING STEEL, AND THREADBAR INDICATING THE ASTM MATERIAL DESIGNATIONS, BAR SIZES, DIMENSIONS, LENGTHS, HARDWARE, AND BEND ARRANGEMENT.

CERTIFICATES OF TREATMENT FOR TIMBER LAGGING.

DRAINAGE AND DEWATERING SYSTEMS, INCLUDING MATERIAL AND LAYOUT.

MONITORING RESULTS FOR SOLDIER BEAMS AND ADJACENT IMPROVEMENTS.

FOR THREADED BARS, STRAPS AND ANCHOR HARDWARE, CERTIFIED MILL TEST REPORTS SATING THAT THE STEEL MEETS OR EXCEEDS THE SPECIFIED REQUIREMENTS AND SHALL INCLUDE THE FOLLOWING INFORMATION:A. IDENTIFICATION AND/OR HEAT NUMBERB. STANDARD CHEMICAL ANALYSIS FOR HEAT OF STEELC. GUARANTEED ULTIMATE TENSILE STRENGTHD. YIELD STRENGTHE. ELONGATION AT FAILUREF. MODULUS OF ELASTICITYG. TIME-DEPENDENT CREEP AND LOAD RELAXATION PROPERTIES (FOR THREADBARS)H. LOAD-STRAIN CURVES (FOR THREADBARS & STRAND)

TEST DATA CERTIFIED THAT ANCHORAGE DEVICES AND THREADBAR COUPLERS HAVE SUITABLE PHYSICAL PROPERTIES TO FULLY DEVELOP THE MINIMUM GUARANTEED ULTIMATE TENSILE STRENGTH OF THE THREADBARS.

STRESSING DATA SHEETS FOR TIEBACKS.

SH-SS

SH-SS1

SHORING - STRUCTURAL STEEL

SEE S0 SERIES SECTION SS FOR STRUCTURAL STEEL NOTES.

SH-A

SH-A1

SH-A2

SH-A3

SH-A4

SH-A5

SH-A6

SH-A7

SH-A8

SHORING - ADJACENT EXITING BUILDING INFORMATION SURVEY AND MONITORING

THE CONTRACTOR SHALL COMPLETE A WRITTEN AND HIGH-QUALITY PHOTOGRAPHIC OR VIDEO LOG OF ALL EXISTING STRUCTURES WITHIN 100 FEET OR THREE TIMES THE DEPTH OF EXCAVATION, PRIOR TO CONSTRUCTION. A LICENSED SURVEYOR SHALL DOCUMENT ALL EXISTING SUBSTANTIAL CRACKS IN ADJACENT EXISTING STRUCTURES.

CONTRACTOR SHALL DOCUMENT EXISTING CONDITION OF WALL CRACKS ADJACENT TO SHORING WALLS PRIOR TO START OF CONSTRUCTION.

CONTRACTOR SHALL MONITOR EXISTING WALLS FOR MOVEMENT OR CRACKING THAT MAY RESULT FROM ADJACENT

SHORING ON A DAILY BASIS DURING EXCAVATION AND ON A WEEKLY BASIS DURING REMAINDER OF CONSTRUCTION. THE SURVEY SHOULD INCLUDE:A. A SURVEY OF REFERENCE POINTS ON ADJACENT EXISTING BUILDING STRUCTURES FOR USE IN A FUTURE

COMPARISON.B. A SURVEY OF EXISTING CONDITIONS OF THE ADJACENT EXISTING BUILDING STRUCTURES FOR USE IN A FUTURE

COMPARISON. THIS SURVEY COULD INCLUDE A DETAILED EXTERIOR/INTERIOR SURVEY OF EXISTING CRACK WIDTHS IN STRUCTURAL/NON-STRUCTURAL ELEMENTS.

C. A SURVEY OF LOCATION, SIZE, AND BOTTOM OF EXISTING ADJACENT PROPERTY FOUNDATIONS SHALL BE PERFORMED IN ORDER TO VERIFY SHORING DESIGN CRITERIA AND MITIGATE DAMAGE TO EXISTING FOUNDATIONS DUE TO DRILLING OPERATIONS

IF EXCESSIVE MOVEMENT OR VISIBLE CRACKING OCCURS, CONTRACTOR SHALL STOP WORK AND SHORE/REINFORCE EXCAVATION AND CONTACT SHORING DESIGN ENGINEER AND THE BUILDING OFFICIAL.

MONITORING SHALL BE PERFORMED BY A LICENSED SURVEYOR AND SHALL CONSIST OF VERTICAL AND LATERAL MOVEMENT OF THE EXISTING STRUCTURES. PRIOR TO STARTING SHORING INSTALLATION, A PRE-CONSTRUCTION MEETING SHALL TAKE PLACE BETWEEN THE CONTRACTOR, SHORING DESIGN ENGINEER, SURVEYOR, GEOTECHNICAL ENGINEER, AND THE BUILDING OFFICIAL TO IDENTIFY MONITORING LOCATIONS ON EXISTING BUILDINGS.

IF IN THE OPINION OF THE BUILDING OFFICIAL OR SHORING DESIGN ENGINEER, MONITORING DATA INDICATE EXCESSIVE MOVEMENT OR OTHER DISTRESS, ALL EXCAVATION SHALL CEASE UNTIL THE GEOTECHNICAL ENGINEER AND SHORING DESIGN ENGINEER INVESTIGATES THE SITUATION AND MAKES RECOMMENDATIONS FOR REMEDIATION OR CONTINUING.

ALL READING AND MEASUREMENTS SHALL BE SUBMITTED TO THE BUILDING OFFICIAL, SHORING DESIGN ENGINEER, AND GEOTECHNICAL ENGINEER.

THE OWNER SHALL CONTACT ADJACENT PROPERTIES OWNERS TO FORMALIZE THE SURVEY REQUIREMENTS AND DECIDE ON ACCEPTABLE SETTLEMENT AND OTHER PERFORMANCE CRITERIA.

SH-M

SH-M1

SH-M2

SH-M3

SHORING - GROUND MONITORING, SOLDIER PILE MONITORING, AND SURVEY

TO ALLOW OUR MITIGATION MEASURES TO BE IMPLEMENTED PROMPTLY IF EXCESSIVE WALL DEFLECTION SHOULD OCCUR, AND OBSERVATION AND MONITORING PROGRAM SHALL BE PERFORMED. THIS MONITORING PROGRAM SHOULD INCLUDE THE ELEMENTS LISTED BELOW. THE CONTRACTOR SHOULD TAKE ANY ADDITIONAL MEASURES HE DEEMS APPROPRIATE TO OBTAIN SPECIFIC INFORMATION OR PROTECTION NECESSARY FOR HIS/HER WORK. A. A CAREFUL AND EXTENSIVE SURVEY OF PRE-CONSTRUCTION CONDITIONS BEHIND THE SHORING.

B. A COMPLETE AND ACCURATE RECORD OF ALL SHORING LOCATIONS, DEPTHS, CONCRETE STRENGTHS, QUALITY OF CONCRETE PER PILE, SHALL BE MAINTAINED BY THE SPECIAL INSPECTOR AND GEOTECHNICAL ENGINEER. THE SHORING DESIGN ENGINEER SHALL BE NOTIFIED OF ANY UNUSUAL CONDITIONS ENCOUNTERED DURING INSTALLATION.

C. MONITORING POINTS SHOULD BE ESTABLISHED AT THE TOP AND AT THE ANCHOR HEADS OF EACH SHORING PILE AND AT INTERMEDIATE INTERVALS AS CONSIDERED APPROPRIATE BY THE GEOTECHNICAL ENGINEER. ALLOW FOR CONSIDERATION OF USING DIGITAL INCLINOMETERS IN COMBINATION WITH OPTICAL SURVEY.

D. REFERENCE POINTS SHOULD BE ESTABLISHED ALONG THE TOP OF ALL SHORING PILES.E. THE ELEVATIONS AND LOCATIONS OF ALL REFERENCE POINTS AND BENCH MARKS SHOULD BE TIED TO A

PERMANENT SURVEY POINT AT A DISTANCE OF AT LEAST 200 FEET FROM THE SHORING. REFERENCE POINTS SHOULD ALSO BE ESTABLISHED ON NEARLY EXISTING BUILDING AND AT OTHER LOCATIONS WITHIN 50 FEET OF THE SHORING.

F. THE LOCATIONS OF THE REFERENCE POINTS SHOULD BE SELECTED BY THE STRUCTURAL ENGINEER IN CONSULTATION WITH THE GEOTECHNICAL ENGINEER & THE CONTRACTOR. THE CONTRACTOR SHOULD PROTECT ALL THE PREFERENCE POINTS.

G. BASELINE SURVEY OF ALL REFERENCE POINTS PRIOR TO THE COMMENCEMENT OF EARTHWORK, AND DAILY SURVEY AT THE BEGINNING OF EXCAVATION FOLLOWED BY LESS FREQUENT SURVEY TOWARDS THE END OF EARTHWORK. AT LEAST TWO ELECTRONIC INCLINOMETERS SHOULD BE INSTALLED ON EACH OF THE FOUR SIDES OF THE EXCAVATION. EACH INCLINOMETER CASING MUST EXTEND AT LEAST 20 FEET BELOW THE DEEPEST EXCAVATION LEVEL. SENSORS FOR THE INCLINOMETERS SHOULD BE SPACED NO MORE THAN 4 FEET APART AND PROVISIONS SHOULD BE MADE FOR CONTINUOUS AND AUTOMATIC READING AND REMOTE DOWNLOADING OF INCLINOMETER DATA.

H. INTERMITTENT OBSERVATION BY THE GEOTECHNICAL ENGINEER OF OTHER GEOTECHNICAL ASPECTS OF THE WORK FOR CORRELATION WITH MEASURED DEFLECTION DATA.

THE OWNER SHALL HIRE A LICENSED SURVEYOR TOA. ESTABLISH CONTROL POINTS OUTSIDE OF THE INFLUENCE ZONE OF THE SHORING SYSTEM AND OBTAIN INITIAL

LINE AND GRADE READINGS PRIOR TO EXCAVATION FROM THE CONTROL POINTS IN ORDER TO ENSURE THE ACCURACY OF THE MONITORING READINGS.

B. MONITOR AND DOCUMENT VERTICAL AND LATERAL MOVEMENTS OF THE SHORING PILES ON A WEEKLY BASIS,

UNTIL THE PERMANENT LATERAL SUPPORT SYSTEM HAS OBTAINED DESIGN STRENGTH OR ENGINEER OF RECORD HAS CONFIRMED THE ABILITY OF THE PERMANENT STRUCTURE TO SUPPORT HE EARTH LOADS.

C. MONITORING READING SHALL BE SUBMITTED TO SHORING DESIGN ENGINEER, ENGINEER IN RESPONSIBLE CHANGE, AND CONTRACTOR WITHIN 3 WORKING DAYS AFTER THEY ARE CONDUCTED. MONITORING READINGS SHALL BE ACCURATE TO WITHIN 0.01 FEET. RESULTS ARE TO BE SUBMITTED IN TABULAR FORM SHOWING AT LEAST THE INITIAL DATE OF MONITORING AND READING, CURRENT MONITORING DATE AND READING AND DIFFERENCE BETWEEN THE TWO READINGS.

UNLESS OTHERWISE NOTED, IF THE VERTICAL OR LATERAL MOVEMENT OF THE SHORING PILES EXCEEDS THE LIMITS LISTED BELOW, AT ANY LOCATION, GEOTECHNICAL ENGINEER AND SHORING ENGINEER SHALL BE NOTIFIED. THE GEOTECHNICAL AND SHORING ENGINEER SHALL EVALUATE SUCH MOVEMENTS.A. IF THE TOTAL CUMULATIVE HORIZONTAL OR VERTICAL MOVEMENT (FROM START OF CONSTRUCTION) OF THE

EXISTING BUILDINGS REACH 1/2" OR SHORING PILES REACHES 1" ALL EXCAVATION ACTIVITIES SHALL BE SUSPENDED. THE GEOTECHNICAL AND SHORING DESIGN ENGINEER SHALL DETERMINE THE CAUSE OF MOVEMENT, IF ANY, AND RECOMMEND CORRECTIVE MEASURES, IF NECESSARY, BEFORE EXCAVATION

CONTINUES.B. IF THE TOTAL CUMULATIVE HORIZONTAL OR VERTICAL MOVEMENT (FROM START OF CONSTRUCTION) OF THE

EXISTING BUILDINGS REACHES 3/4" OR SHORING PILES REACHES 1 1/2" ALL EXCAVATION ACTIVITIES SHALL BE SUSPENDED UNTIL THE CAUSE, IF ANY, CAN BE DETERMINED.

SH-I

SH-I1

SH-I2

SH-I3

SH-I4

SH-I5

SH-I6

SHORING - PROCEDURES FOR SOLDIER PILE INSTALLATION

INSTALLATION OF SOLDIER PILES SHOULD BE PERFORMED UNDER THE CONTINUOUS OBSERVATION OF THE GEOTECHNICAL ENGINEER & SHORING ENGINEER IF THE SOLDIER PILES ARE TO BE PART OF THE PERMANENT CONSTRUCTION, OTHERWISE INTERMITTENT OBSERVATION WILL SUFFICE. IN ALL CASES, THE SPECIAL INSPECTOR SHOULD BE PRESENT FOR THE PLACEMENT OF SOLDIER PILES AND CONCRETE.

THE SOLDIER PILES SHALL BE PLACED WITHIN SPECIFIED TOLERANCES IN THE DRILLED HOLE AND BRACED AGAINST DISPLACEMENT DURING GROUTING. FILL SHAFTS WITH CONCRETE UP TO TOP OF FOOTING ELEVATION, REST OF THE SHAFT CAN GENERALLY BE FILLED WITH LEAN CONCRETE. EXCAVATION FOR LAGGING SHALL NOT BE STARTED UNTIL CONCRETE HAS ACHIEVED SUFFICIENT STRENGTH FOR ALL ANTICIPATED LOADS AS DETERMINED BY THE SHORING DESIGN ENGINEER.

WHERE BOULDERS AND/OR COBBLES HAVE BEEN IDENTIFIED IN THE GEOTECHNICAL REPORTS, CONTRACTOR SHALL BE PREPARED TO ADDRESS BOULDERS AND/OR COBBLE THAT MAY BE ENCOUNTERED DURING THE DRILLING OF SHORING PILES.

DRILL SOLDIER PILE CAISSONS.A. SHORING PILES SHOULD BE INSTALLED USING AUGER DRILLING METHODS WITH CASING, AS

NEEDED, IN ORDER TO MINIMIZE THE POTENTIAL IMPACT OF VIBRATIONS ON NEARBY BUILDINGS AND OCCUPANTS. THE CONTRACTOR SHOULD BE AWARE THAT THE GROUNDWATER CONDITIONS AT THE PROPOSED SITES ARE ANTICIPATED TO BE VARIABLE, AND IT IS LIKELY THAT GROUNDWATER WILL BE ENCOUNTERED IN THE HOLES DRILLED FROM THE SOLDIER PILES. THE CONTRACTOR SHOULD BE PREPARED TO CASE THE HOLE, IF NECESSARY. REFERENCE GENERAL NOTES ON S0.02 FOR ADDITIONAL INFORMATION REGARDING GROUNDWATER.

B. AUGER DRILLING WITHOUT CASING MAY BE CONSIDERED IF THE OBSERVED FIELD CONDITIONS ARE CONDUCTIVE TO THE USE OF SUCH A METHOD.

PLACE SOLDIER PILES WITH POSITIVE MEANS OF SECURING IN PLACE DURING POURING OF CONCRETE. SOLDIER PILES SHALL BE WITHIN 2 INCHES OF THEIR THEORETICAL LOCATION IN ALL DIRECTIONS, EXCEPT THERE SHALL BE NO TOLERANCE ALLOWED INWARD TOWARD THE EXCAVATION. PLUMBNESS TOLERANCE OF SHORING PILES SHALL BE 0.5/100. SHORING PILES SHALL NOT ENCROACH

UPON PERMANENT WORK.

FILL CAISSONS WITH STRUCTURAL CONCRETE BELOW BOTTOM OF EXCAVATION AND WITH LEAN CONCRETE ABOVE BOTTOM OF EXCAVATION. PLACE CONCRETE THROUGH A RIGID TREMIE OR PUMP PIPE LOCATED WITHIN ONE FOOT OF THE BOTTOM OF THE CAISSON AT THE BEGINNING OF CONCRETING AND MAINTAINED A MINIMUM OF 5 FEET AND A MAXIMUM OF 10 FEET BELOW THE SURFACE OF THE CONCRETE THEREAFTER.

SH-P

SH-P1

SH-P2

SH-P3

SHORING - PROTECTION OF EXISTING IMPROVEMENTS

THE FOLLOWING PROTECTIVE ACTIONS ARE ALSO RECOMMEND IN ADDITION TO BASIC SHORING:A. PREVENT GROUND LOSS IN ALL EXCAVATIONS BY USING PROPER SHORING METHODS, PROCEDURES, AND

SEQUENCING.B. IDENTIFY AND PROTECT EXISTING UTILITIES. THE LOCATIONS, METHODS, AND EXTENT OF UTILITY PROTECTION

MEASURES - AS WELL AS THE RESPONSIBILITY - THEREFORE SHOULD BE THE CONTRACTOR'S. THE CONTRACTOR SHOULD BE ESPECIALLY ALERT TO THE LOCATIONS OF EXISTING UTILITIES IN THE NEAR VICINITY OF THE PROPOSED TIEBACKS. THE LOCATIONS OF THESE UTILITIES SHOULD BE CLEARLY IDENTIFIED. IF NECESSARY, UTILITIES SHOULD BE RELOCATED.

THE CONTRACTOR SHOULD DOCUMENT EXISTING CONDITIONS BEFORE THE COMMENCEMENT OF EXCAVATION TO PROVIDE A BASIS OF COMPARISON FOR FUTURE OBSERVATIONS. THIS DOCUMENTATION SHOULD INCLUDE DATED PHOTOGRAPHS OF SPECIFIC FEATURES OR EXISTING DAMAGE. A NARRATIVE VIDEO CAN BE PREPARED IN LIEU OF PHOTOGRAPHS. OF EXCAVATION TO PROVIDE A BASIS OF COMPARISON FOR FUTURE OBSERVATIONS THIS DOCUMENTATION SHOULD INCLUDE DATED PHOTOGRAPHS OF SPECIFIC FEATURES.

THE CONTRACTOR SHALL ALSO BE RESPONSIBLE FOR THE PROTECTION OF EXISTING AND NEW MONITORING POINTS, LOAD CELLS, AND INCLINOMETERS UNTIL THE COMPLETION OF CONSTRUCTION.

SH-D

SH-D1

SH-D2

SHORING DESIGN CRITERIA

MINIMUM SOLDIER PILE SPACING = 3D

SHAFT FRICTION = 600 PSF

MAX LAGGING PRESSURE = 400 PSF

SURCHARGE PRESSURE = SEE GEOTECH REPORT

CANTILEVERED SHORING CRITERIA

LATERAL PRESSURE = 35H PCF

PASSIVE PRESSURE = 400H PCF UP TO 6000 PSF MAX

H

TH

OM

AS

CA

LU

S

16

20

SU

MM

ITR

IDG

E D

RIV

E,

BE

VE

RL

Y H

ILL

S, C

A 9

02

10

SU

D

da

tesh

ee

t title

sh

ee

t nu

mb

er

revis

ion

sclie

nt

dra

wn b

y

da

te

f:e

:31

0. 4

24.5

230

p:31

0.92

9.78

15in

fo@

dom

aen.

net

915

mat

eo s

treet

suite

205

los

ange

les

ca

9002

1

ww

w.d

omae

n.ne

t

EXP 03/31/2019C80463

STATE OF CALIFORN IA

ELIZ

ABE H MAHLOW

REG

IST

ERED

PROFESS IONA L ENGIN

EER

C I V IL

T

600

WIL

SH

IRE

BLV

D, S

UIT

E 7

60LO

S A

NG

ELE

S, C

A 9

0017

213

627

6687

CO

NTA

CT

@N

OU

SE

NG

INE

ER

ING

.CO

M

NOT FOR CONSTRUCTION

SH

OR

ING

GE

NE

RA

L N

OT

ES

SH

0.00

AS

P

01/0

4/1

9

1901

11 S

UD ­

STRU

CTUR

AL P

ROGR

ESS

Page 24: GENERAL NOTES, ABBREVIATIONS, & SHEET LIST · 2019-07-15 · dc -6 wind design: dc dc -1 design criteria dc -2 dc -3 live loads ... scbf special concentrically braced frame sched

(E) STRUCTURE WHERE OCCURS SEE PLANS AND SECTION[VIF]

GUARDRAIL SAFETY CABLE RAILING SYSTEM PER OSHA REQUIREMENTS TYPICAL AROUND ENTIRE PROJECT

PR

OP

ER

TY

LIN

E

WH

ER

E O

CC

UR

S

MIN

1'

-0"

PER SCHEDULE

d

PE

R S

CH

ED

ULE

H

PE

R S

CH

ED

ULE

EM

BE

DM

EN

T D

EP

TH

, D

SOLDIER PIER PER SCHEDULE SEE PLAN FOR LOCATION

BOE [VIF]

TOP OF GRADE (VIF)

SH

AF

T FI

LL A

BO

VE

BO

E

SE

E S

CH

ED

ULE

FO

R

SH

AFT

FIL

L B

ELO

W B

OE

SE

E S

CH

ED

ULE

FO

R

NOTES:1. LAGGING NOT SHOWN FOR CLARITY.2. TEMPORARY SHORING SHALL NOT ENCROACH ON ADJACENT PROPERTY, WITHOUT WRITTEN APPROVAL FROM OWNER.3. ALL UNDERGROUND UTILITIES AND (E) STRUCTURES SHALL BE FIELD VERIFIED BEFORE SHORING BEGINS.4. MAX 1:1 CUT ABOVE SHORING WHERE NO EXISTING STRUCTURE OR PROPERTY LINE OCCURS.

SEE NOTE 4

1

1

1 2 3 4

FINAL

SEQUENCE OF PILE INSTALLATIONSTEP 1: DRILL SOLDIER PILE HOLE. USE DRILLING FLUID, CASING, OR CFA AS REQUIRED.

STEP 2: INSTALL SOLDIER PILE (INCLUDES PLACEMENT AND CONCRETING OF PILE AND DEWATERING SYSTEM).

STEP 3: INSTALL WOOD LAGGING AS EXCAVATION PROCEEDS.

STEP 7: INSTALL PERMANENT WALL.

DRAINAGE BOARD PER ARCH

CONTINUOUS WATERPROOF MEMBRANE PER ARCH

4X8 TREATED WOOD LAGGING

BACKFILL WITH GRANULAR FILL TO ACHIEVE FULL BEARING (WHERE REQUIRED BY THE GEOTECH)

MA

X A

LLO

W T

OLE

RA

NC

E O

F L

OC

AT

ION

= 1

1/2

"

PIL

E S

PA

CIN

G P

ER

PLA

N

CONTINUOUS LONGITUDINAL REINF PER SCHEDULE

CONTINUOUS SPIRAL REINF PER SCHEDULE

CHIP AWAY CONCRETE COVER AND REMOVE LOOSE MATERIAL W/ WIRE BRUSH

#5 DOWEL @ 6" OCVERTICAL EACH SIDE

SIMPSON SET-XP EPOXY ANCHORAGE W/ MIN 12" EMBED(LARR 25744)

VOID FORM AS REQUIRED

TYP

Ls

NOTES:1. SEE RETAINING WALL DETAIL FOR DRAINAGE AND WALL RC WALL INFORMATION NOT SHOWN.

LAGGING PER SCHEDULE INSTALL (2) 20d NAILSBENT INTO LAG EITHER SIDE OF RAKER INSERTION POINTEACH END OF LAG, TYP

L4X4X3/8 CONTINUOUS

DRILL AND EPOXY 1/2" DIA FULLY THREADED RODS @ 16" OC W/ 6" EMBED

MAIN LEVEL T.O.C.1012'-1 3/4"

UPPER LEVEL T.O.C.1024'-0 1/4"

2

BASEMENT T.O.C.1001'-3 3/4"

1

T.O.F.989'-3 3/4"

MAIN LEVEL T.O.C.1012'-1 3/4"

UPPER LEVEL T.O.C.1024'-0 1/4"

2

BASEMENT T.O.C.1001'-3 3/4"

1

T.O.F.989'-3 3/4"

MAIN LEVEL T.O.C.1012'-1 3/4"

UPPER LEVEL T.O.C.1024'-0 1/4"

2

BASEMENT T.O.C.1001'-3 3/4"

1

T.O.F.989'-3 3/4"

S5.00

6

TH

OM

AS

CA

LU

S

16

20

SU

MM

ITR

IDG

E D

RIV

E,

BE

VE

RL

Y H

ILL

S, C

A 9

02

10

SU

D

da

tesh

ee

t title

sh

ee

t nu

mb

er

revis

ion

sclie

nt

dra

wn b

y

da

te

f:e

:31

0. 4

24.5

230

p:31

0.92

9.78

15in

fo@

dom

aen.

net

915

mat

eo s

treet

suite

205

los

ange

les

ca

9002

1

ww

w.d

omae

n.ne

t

EXP 03/31/2019C80463

STATE OF CALIFORN IA

ELIZ

ABE H MAHLOW

REG

IST

ERED

PROFESS IONA L ENGIN

EER

C I V IL

T

600

WIL

SH

IRE

BLV

D, S

UIT

E 7

60LO

S A

NG

ELE

S, C

A 9

0017

213

627

6687

CO

NTA

CT

@N

OU

SE

NG

INE

ER

ING

.CO

M

NOT FOR CONSTRUCTION

TY

PIC

AL

SH

OR

ING

DE

TA

ILS

SH

0.10

AS

P

01/0

4/1

9

NOT TO SCALE

DRILLED CANTILEVER SHORING4

NOT TO SCALE

TYPICAL SOLDIER PILE WALL CONSTRUCTION SEQUENCE - CANTILEVER WALL5

NOT TO SCALE

PILE RETAINING WALL7

NOT TO SCALE

LAGGING ALTERNATE8

SHORING PILE SCHEDULE

PILEMARK

DIALENGTH OF PILE,

LEMBED DEPTH,

DASSUMED DEPTH OF FILL,

FVERTICAL

BARSSPIRAL

SIZESPIRAL

SPACING

SP1 2'-0" 39'-0" 15'-0" 24'-0"

SP2 2'-0" 39'-0" 15'-0" 24'-0"

SP3 2'-0" 39'-0" 15'-0" 24'-0"

SP4 2'-0" 39'-0" 15'-0" 24'-0"

SP5 2'-0" 39'-0" 15'-0" 24'-0"

SP6 2'-0" 39'-0" 15'-0" 24'-0"

SP7 2'-0" 39'-0" 15'-0" 24'-0"

SP8 2'-0" 39'-0" 15'-0" 24'-0"

SP9 2'-0" 39'-0" 15'-0" 24'-0"

SP10 2'-0" 39'-0" 15'-0" 24'-0"

SP11 2'-0" 39'-0" 15'-0" 24'-0"

SP12 2'-0" 39'-0" 15'-0" 24'-0"

SP13 2'-0" 39'-0" 15'-0" 24'-0"

SP14 2'-0" 39'-0" 15'-0" 24'-0"

SP15 2'-0" 39'-0" 15'-0" 24'-0"

SP16 2'-0" 39'-0" 15'-0" 24'-0"

SP17 2'-0" 39'-0" 15'-0" 24'-0"

SP18 2'-0" 39'-0" 15'-0" 24'-0"

SP19 2'-0" 39'-0" 15'-0" 24'-0"

1/4" = 1'-0"

PILE SECTION10 1/4" = 1'-0"

PILE SECTION9 1/4" = 1'-0"

PILE SECTION11 19

0111

SUD

­ ST

RUCT

URAL

PRO

GRES

S

Page 25: GENERAL NOTES, ABBREVIATIONS, & SHEET LIST · 2019-07-15 · dc -6 wind design: dc dc -1 design criteria dc -2 dc -3 live loads ... scbf special concentrically braced frame sched

2

3

A

1

BCDEFGHI

4

5

6

7

EQ EQ EQ EQ

8'-0" 8'-0" 8'-0" 8'-0"

7'-0" 7'-0" 7'-0" 7'-0" 7'-0" 7'-0" 7'-0"

SP1 SP2 SP3 SP4 SP5 SP6

SP7 SP8 SP9 SP10 SP11 SP12 SP13 SP14 SP15 SP16 SP17 SP18

8'-0"2'-0"

9

SH0.10

10

SH0.10

HOUSE UNDER SEPARATE PERMIT.

SEE S SERIES SHEETS

11

S5.00

SP19

11

SH0.10

1. LAGGING BETWEEN SHORING PILES IS NOT ANTICIPATED. IF DETERMINED DURING CONSTRUCTION

PHASE THAT LAGGING IS REQUIRED THE CONTRACTOR SHOULD BE PREPARED TO INSTALL LAGGING

AS NECESSARY.

SHORING PLAN NOTES

SHORING PLAN LEGEND

INDICATES LAGGING LOCATION BETWEEN PILES

INDICATES SHORING PILE PER SP# 4 / SH0.10

TH

OM

AS

CA

LU

S

16

20

SU

MM

ITR

IDG

E D

RIV

E,

BE

VE

RL

Y H

ILL

S, C

A 9

02

10

SU

D

da

tesh

ee

t title

sh

ee

t nu

mb

er

revis

ion

sclie

nt

dra

wn b

y

da

te

f:e

:31

0. 4

24.5

230

p:31

0.92

9.78

15in

fo@

dom

aen.

net

915

mat

eo s

treet

suite

205

los

ange

les

ca

9002

1

ww

w.d

omae

n.ne

t

EXP 03/31/2019C80463

STATE OF CALIFORN IA

ELIZ

ABE H MAHLOW

REG

IST

ERED

PROFESS IONA L ENGIN

EER

C I V IL

T

600

WIL

SH

IRE

BLV

D, S

UIT

E 7

60LO

S A

NG

ELE

S, C

A 9

0017

213

627

6687

CO

NTA

CT

@N

OU

SE

NG

INE

ER

ING

.CO

M

NOT FOR CONSTRUCTION

SH

OR

ING

PLA

NS

H1.

00

AS

P

01/0

4/1

9

3/16" = 1'-0"

SHORING PLAN1

1901

11 S

UD ­

STRU

CTUR

AL P

ROGR

ESS