GENERAL
1. The structure has been designed for the in-service loads only. The methods, procedures, and sequences of construction are the responsibility of the Contractor. The Contractor shall take all necessary precautions to maintain and ensure the integrity of the structure at all stages of construction.
2. All work shall be performed in accordance with the Indiana Building Code, 2014 Edition (2012 International Building Code, first printing, with Indiana Amendments).
3. Do not determine dimensions by "scaling" off the plans. The Contractor shall accept all risk associated with "scaling" and shall be responsible for all inadequate work resulting therefrom. Questions regarding missing or conflicting dimensions shall be directed, in writing, to the Structural Engineer.
4. The location of sleeves or openings not shown in structural members shall be approved by the Structural Engineer.
5. The Contractor shall relocate all utilities which interfere with the proposed construction. Service shall be maintained at all times during utility relocation unless otherwise noted.
GENERAL STRUCTURAL NOTES All notes hereafter are typically applicable unless notes otherwise on plans, sections, or details.
FOUNDATIONS
1. Exterior footings shall bear 3'-0" minimum below finish grade and shall bear on undisturbed soil.
2. Foundation and soils related work shall be performed under the direct supervision of a qualified Geotechnical Engineer.
3. Foundation excavations shall be made to plan elevations. The Contractor shall have a qualified Geotechnical Engineer verify that the allowable soil bearing pressure meets or exceeds that assumed for the foundation design. If the underlying soils are found to be unacceptable, one of the following procedures shall be followed:
A. Remove the unacceptable soil and backfill with an engineered structural fill as directed by the inspecting Geotechnical Engineer.
B. Lower the footing to an acceptable soil. Contact the Structural Engineer for potential modifications to the foundation system.
4. Foundation conditions noted during construction, which differ from those assumed shall be reported to the Architect and Structural Engineer before further construction is attempted.
CONCRETE
1. Reinforced concrete has been designed in accordance with the latest edition[s] of the Building Code Requirements for Reinforced Concrete (ACI 318) by the American Concrete Institute (ACI).
2. Slabs-on-grade shall be constructed in accordance with the latest edition of the Guide for Concrete Floor and Slab Construction (ACI 302.1R).
3. Mixing, transporting, and placing of concrete shall conform to the latest edition of the Standard Practice for Selecting Proportions for Normal, Heavyweight, and Mass Concrete (ACI 211.1) and the Standard Specifications for Structural Concrete (ACI 301). Concrete curing shall conform to the latest editions of the Standard Practice for Concrete Curing (ACI 308) and the Standard Specification for Curing Concrete (ACI 308.1). In case of a discrepancy, the plans and specifications shall govern.
4. Unless noted otherwise, concrete shall have natural sand fine aggregate and normal weight coarse aggregates conforming to ASTM C33, and Type I or III Portland Cement conforming to ASTM C150.
5. Unless noted otherwise, fly ash may be used as a pozzolan to replace a portion of the Portland Cement in a concrete mix. Fly ash, when used, shall conform to ASTM C618, Type C. Concrete mixes using fly ash shall be proportioned to account for the properties of the specific fly ash used and to account for the specific properties of the fly ash concrete thus resulting. The ratio of the amount of the fly ash to the total amount of fly ash plus cement in the mix shall not exceed 20 percent.
6. Unless noted otherwise, ground granulated blast-furnace slag (GGBFS) may be used to replace a portion of the Type I Portland Cement in a concrete mix. Ground granulated blast-furnace slag, when used, shall conform to ASTM C989, Grade 100 or 120. Concrete mixes using GGBFS shall be proportioned to account for the properties of the specific GGBFS used and to account for the specific properties of the GGBFS concrete thus resulting. The ratio of the amount of the GGBFS to the total amount of GGBFS plus cement in the mix shall not exceed 40 percent.
7. Water-reducing admixtures conforming to ASTM C494 may be used in the concrete mix design. Maximum slump shall be 5 inches for mixes containing water-reducing admixtures and 5 to 8 inches for mixes containing high range water-reducing admixtures.
8. Concrete compressive strength tests shall be performed in accordance with ASTM C39. Copies of the test results shall be forwarded to the Architect and Structural Engineer. One set of specimens shall be taken for each day's pour of appreciable size and for each 50 cubic yards in accordance with the latest edition of ASTM C31. Each set shall include one specimen tested at 7 days, 2 specimens tested at 28 days and one specimen retained in reserve. These test cylinders shall be laboratory cured.
9. When the ambient temperature is expected to fall below 40 degrees during the course of a concrete pour or subsequent curing period, it shall be placed and cured in accordance with the latest edition of Cold Weather Concreting (ACI 306R) and an additional set of concrete test cylinders shall be made. These cylinders shall be stored immediately adjacent to, and cured under the same conditions as the building concrete. Special curing boxes are not permitted for these test cylinders.
10. Concrete mixed, transported, placed, and cured under conditions of high ambient temperature, low humidity, solar radiation, or high winds shall conform to the latest edition of Hot Weather Concreting (ACI 305R) and an additional set of concrete test cylinders shall be made. These cylinders shall be stored immediately adjacent to, and cured under the same conditions as the building concrete. Special curing boxes are not permitted for these test cylinders.
11. Slump tests shall be made prior to and following the addition of plasticizers. Where concrete is placed by pumping methods, concrete for test cylinders and slump tests shall be taken at the point of final placement.
12. Water shall not be added to the concrete at the job site. The Contractor is responsible for coordinating a pumpable and workable mix without the addition of water at the job site. The use of plasticizers, retardants and other additives shall be at the option of the Contractor subject to the approval of the Structural Engineer. Follow the recommendations of the manufacturer for the proper use of additives. Use of calcium chloride or other chloride bearing salts is prohibited.
13. Place concrete in a manner so as to prevent segregation of the mix. Delay floating and troweling operations until the concrete has lost surface water sheen or all free water. Do not sprinkle free cement on the slab surface. Finishing of slab surfaces shall conform to the latest editions of ACI 302.1R and ACI 304R (Guide for Measuring, Mixing, Transporting and Placing Concrete).
14. Maintain concrete in a moist condition for at least 5 days at ambient temperatures above 70 degrees, and at least 7 days at ambient temperatures above 50 degrees. Curing compounds or moisture retention covers shall be used for all non-formed surfaces. Formed surfaces shall be cured by leaving forms in place. During hot, dry weather, keep forms moist by sprinkling. When forms are removed prior to the end of the curing period, apply curing compound to the exposed surfaces.
15. All interior slabs shall receive a hard “troweled finish”. Exterior slabs, sidewalks, and stoops shall receive a “broom (or other type of slip resistant) finish”. All formed surfaces not exposed to public view shall receive a “rough form finish”, exposed surfaces shall receive a “smooth form finish”. Concrete finishes shall be as defined in ACI 301.
16. Protect finished concrete surfaces from damage, rain, hail, running water, other injurious effects.
17. Protect the concrete surface between finishing operations on hot, dry days or any time plastic shrinkage cracks could develop by using wet burlap, plastic membranes or fogging.
18. Construction joints shall be prepared by roughening the contact surface in an approved manner to a full amplitude of approximately 1/4 inch leaving the contact surface clean and free of laitance.
19. Contraction joints shall be made in concrete slabs-on-grade at major column centerlines, at points of discontinuity, at reentrant corners, and at other locations shown on the plans.
20. Provide 3/4-inch chamfers on all exposed corners of concrete except those abutting masonry.
21. The Contractor shall verify the location of sleeves, openings, embedded items, etc. and shall ensure that they are in place prior to the placement of the concrete.
22. Earth cuts may be used as forms (“bank forming”) for vertical or sloping surfaces. Where bank forming is permitted, the concrete element shall be increased at least 3 inches on all sides exposed to earth to account for possible soil contamination during concrete placement.
CONCRETE SCHEDULE
CONCRETE SCHEDULE
CLASS f ′ CONCRETE PLACEMENT
REMARKS
A 3,000 psiFOUNDATION WALLS
AND THICKNED SLABS
AIR CONTENT
OPTIONAL
B 4,000 psiELEVATED SLAB ON
METAL DECK
MIN. CEMENT:
LB/CY (SACKS/CY)
c
423 (4.5)
517 (5.5)
MAX. WATER/ CEMENT
RATIO
0.58
0.48
EXTERIOR SLABS-ON-GRADE, STOOPS,
CURBS, & SIDEWALKS EXPOSED TO DE-ICERS
611 (6.5) 0.40C 4,500 psi 6% ± 1% SYNTHETIC FIBERS
(1.5 LBS/CYS)
OPTIONAL
REINFORCING STEEL
1. Reinforcing bar detailing, fabricating, and placing shall conform to the latest edition of the following standards: Specifications for Structural Concrete for Buildings (ACI 301), ACI Detailing Manual (SP66). The latest editions of Concrete Reinforcing Steel Institute's Reinforcing Bar Detailing and Placing Reinforcing Bars may also be used.
2. Provide standard bar chairs, slab bolsters, spacers, etc. as required to maintain concrete protection specified. Reinforcing steel shall be tied to prevent displacement during concrete placement. Pulling up of welded wire fabric in slabs-on-ground is not permitted.
3. Reinforcement bars shall not be tack welded, welded, heated or cut unless otherwise indicated or approved by the Structural Engineer.
4. Welding of reinforcement bars, when approved by the Structural Engineer, shall conform to the latest edition of American Welding Society Standard D1.4. Electrodes for shop and field welding of reinforcement bars shall conform to ASTM A233, Class E90XX.
5. Concrete cover over reinforcement, unless otherwise noted, shall be as specified in the latest edition of ACI 318.
6. Unless noted otherwise, splicing of reinforcing bars shall conform to the latest edition of ACI 318. Where the length of lap is not indicated, provide a Class "B" lap at tension splices or 30 bar diameter compression laps at compression splices.
MASONRY
1. Engineered concrete masonry has been designed in accordance with the latest edition of the ACI Building Code Requirements for Masonry Structures (ACI 530/ASCE 5).
2. Concrete masonry construction shall conform to the latest edition of the ACI Specifications for Masonry Structures (ACI 530.1/ASCE 6).
3. Mortar shall be type N for interior non-load bearing walls. For exterior and load bearing walls, mortar shall be type M below grade and type S above grade. Mortar shall conform to the requirements of the latest edition of ASTM C270. Portland Cement-lime without air entrainment shall be used in the mortar mix.
4. Provide standard spacers, etc. as required to prevent reinforcing steel displacement during grout placement.
5. Provide reinforcing steel in vertical cores as indicated. In addition, provide reinforcing steel in vertical cores on each side of all openings and each corner of all walls. Grout cores with reinforcing steel solid.
6. Reinforcing steel lap splices in concrete masonry shall be as noted below unless otherwise noted. All splices shall be wired together.
7. Masonry cores (where specified) and bond beams shall be filled with coarse grout conforming to the requirements of the latest edition of ASTM C476 and having a minimum 28-day compressive strength of 3,000 psi, 3/4 inch maximum aggregate, and an 8 to 11 inch maximum slump.
8. The Contractor shall prepare detailed working or shop drawings to enable him to fabricate, erect and construct all parts of the work in accordance with the drawings and specifications and shall submit one reproducible copy and one blue line copy to the Structural Engineer for review prior to fabrication. These shop drawings will be reviewed for design concepts only. The Contractor shall be responsible for all dimensions, accuracy, and fit of work.
MASONRY REINFORCING STEEL LAP SPLICE SCHEDULE
f ′ = 1500 psi
BAR SIZE #3 #4
m
#5 #6 #7 #8
8" CMU
12" CMU
1'-7"
1'-7"
2'-7"
2'-7"
2'-7"
2'-7"
4'-9"
4'-4"
6'-7"
5'-1"
9'-5"
6'-3"
POST-INSTALLED EXPANSION/ADHESIVE ANCHORS
1. Post-installed anchors shall only be used where specified on the Construction Documents. The Contractor shall obtain approval from the Structural Engineer prior to installing the post-installed anchors in place of missing or misplaced cast-in-placed anchors.
2. Care shall be taken in placing post-installed anchors to avoid conflicts with existing reinforcing steel.
3. Post-installed anchors shall be installed by qualified personnel in accordance with the drawings and specifications.
4. Post-installed anchors shall be installed by qualified personnel in accordance with the Manufacturer’s Printed Installation Instructions (MPII), the drawings and specifications. Installation of adhesive anchors shall be performed by personnel trained to install adhesive anchors. Contractor shall submit installer training cards with anchor package.
5. Post-installed anchors shall be HILTI type as manufactured by HILTI Fastening Systems or approved equivalent. Substitution requests must be submitted by the Contractor to the Structural Engineer for review. Provide back-up technical data that demonstrates that the substituted product is capable of achieving the equivalent performance values (minimum) of the specified products using the appropriate design procedure and/or standard(s) as required by the building code.
6. The Contractor shall inspect the concrete surface at each proposed post-installed anchor location prior to installation. If the concrete is honeycombed, cracked or otherwise unsound, the anchors shall be repositioned so as to be located in sound material and be in accordance with the manufacturer’s minimum spacing and edge distance requirements.
7. Adhesive anchors shall be subject to the following additional requirements:
A. Anchors shall meet the requirements of ACI 355.2 (mechanical anchors) and ACI 355.4 (adhesive anchors).
B. Proof loading of adhesive anchors is not required.C. Anchors shall not be installed in concrete cured less than 21-daysD. Anchors shall not be installed until the concrete has reached a minimum compressive strength of
2,500 psi.E. Concrete temperature must be greater than 50 ˚F and less than 80 ˚F prior to installation of the
anchors unless otherwise permitted by the MPII.F. Anchors shall be installed in holes drilled with the HILTI Hollow Drill Bit (TE-CD (SDS Plus) or TE-YD
(SDS Max)) and HILTI VC 20/40 Vacuum (VC 20-U or VC 40-U). Follow the MPII for size and depth of holes required.
G. The acceptability of certification other than the ACI/CRSI Adhesive Anchor Installer Certification shall be the responsibility of the Structural Engineer.
H. Adhesive anchors installed in horizontal or upwardly inclined orientations to resist sustained tension loads shall be continuously inspected during installation by an inspector specially approved for that purpose by the building official. The special inspector shall furnish a report to the licensed design professional and building official that the work covered by the report has been performed and that the materials used and the installation procedures used conform to the approved contract documents and MPII.
NON-SHRINK GROUT
1. Grout shall be a high early strength, non-metallic, shrinkage resistant (when tested in accordance with the latest edition of ASTM C827 or CRD-C621), premixed, non-corrosive, non-staining product conforming to the requirements of the latest edition of ASTM C1107 and containing Portland Cement, silica sands, shrinkage compensating agents and fluidity improving compounds.
2. Grout compressive strength tests shall be performed in accordance with the latest edition of ASTM C109, with a restraining plate placed over the molds.
3. Grout shall be installed in accordance with the manufacturer's instructions.
4. Grout shall be placed in a non-sag flowable state and shall have forms built around it for confinement. Grout shall be cured according to manufacturer's recommendations.
DESIGN
1. Building Code:Indiana Building Code, 2014 Edition (2012International Building Code, first printing, with Indiana Amendments)
2. Soil information:Allowable net bearing pressure:
Spread footings 2,000 psf (assumed)Continuous wall footings 1,500 psf (assumed)
Soil subgrade modulus, Ks 100 pci (assumed)Unit weight of soil 125 pcf (assumed)Coefficient of friction between soil and concrete footing 0.35 (assumed)
3. Concrete:28 day compressive strength (f'c) See Schedule
4. Reinforcing steel (deformed bars of new billet steel):Stirrup and tie ASTM A615, Grade 60Weldable (Low-Alloy) ASTM A706, Grade 60Otherwise ASTM A615, Grade 60Welded wire fabric (smooth) ASTM A185
5. Structural Steel:Structural Tubing members ASTM A500, Grade B, Fy = 46 ksiStructural steel rolled wide flange W shapes ASTM A992, Fy = 50 ksiStructural steel rolled channels ASTM A36Structural steel rolled plates & angles ASTM A36
6. Non-shrink grout:28 day compressive strength 6,500 psi
7. Structural Lumber (surfaced dry, used at 19% moisture content) [unless noted otherwise]:Loading bearing wall headers See scheduleLoad bearing wall studs See scheduleAll other members Southern Pine, No. 2Bolts/Lag Screws ANSI/ASME B18.2Nails FF-N-105B
LVL or Microlams Fb=2,950 psiFv=285 psiE= 2.0 million psi
8. Live Loads:Roof 20 psf1st Floor - elevated deck 100 psf
9. Risk Category II
10. Snow Loads:Ground snow load, Pg 20 psfTerrian factor BSnow exposure factor, Ce 1.0Thermal factor, Ct 1.0Snow importance factor, Is 1.0Flat-roof snow load, Pf 14 psfMinimum low slope roof snow load, Pm 20 psfRain-on-snow surcharge load 5 psfDesign flat-roof snow load 25 psf with drift considerations
11. Wind Loads:Basic wind speed (3-second gust) 115 mphWind importance factor, IW 1.0Exposure BInternal pressire coefficient, GCpi 0.18
12. Seismic Loads:Seismic importance factor, Ie 1.0Mapped spectral response acceleration at short periods, Ss 18.5% gMapped spectral response acceleration at 1 Second, S1 8.5% gSite class DShort period site coefficient, Fa 1.6Long period site coefficient, Fv 2.4Spectral response acceleration at short periods, Sds 19.5% gSpectral response acceleration at 1 Second, Sd1 13.5% gSeismic design category CBasic seismic force resisting system Wood Structural PanelsResponse modification factor, R 6.5Base shear at 1st Floor 0.047WAnalysis procedure used Equivalent lateral force
STRUCTURAL LUMBER
1. Structural lumber shall be detailed, fabricated and erected in accordance with the latest editions of the Timber Construction Manual by the American Institute of Timber Construction (AITC) and the National Design Specification for Wood Construction by the American Forest & Paper Association (ANSI/NFoPA NDS).
2. Bolts, lag screws, nails and other wood fastenings, unless otherwise noted, shall conform to the latest edition of the National Design Specification for Wood Construction. Standard cut washers shall be used between the wood and bolt head and the wood and nut.
3. Strapping, holddowns, clips, hangers, and connection plates shall be as manufactured by Simpson Strong-Tie Company, Inc. or approved equivalent.
4. Except where epoxy injection is specified; bolted, lag screwed, or nailed wood member connections shall be glued using adhesives conforming to APA Specification AFG-01 (PL-400) in accordance with the manufacturer's recommendations.
5. Structural load bearing wall studs, not otherwise continuously braced on both sides by gypsum board, plywood/performance rated panel sheathing, hardboard panel siding, or other Indiana Building Code (IBC) approved sheathing; shall be braced at third points with horizontal solid wood blocking in accordance with Chapter 23 of the IBC (Section 2308.9.9) not less than 2 inches (nominal) in thickness and of the same width as the studs fitted snugly and nailed thereto to provide adequate lateral support.
6. Wood members that are in contact with concrete or masonry or exposed to weather shall be pressure treated with a water borne treatment to a net retention level of 0.3 pcf in accordance with applicable American Wood Preservers' Association latest requirements.
7. Rough sawn timbers shall be treated and finished where specified. Ends exposed to weather shall be treated with CCA.
PLYWOOD/PERFORMANCE RATED PANELS
1. Plywood and performance rated panels (oriented strand board) shall be detailed, fabricated and erected in accordance with the latest criteria established by the American Plywood Association (APA) including their latest edition of the Plywood Design Specification (and its Supplements).
2. Plywood panels shall be identified with the appropriate trademark of the APA and shall meet the requirements of the International Building Code.
3. Roof panels shall be installed with the long dimension (face grain) across the supports with panels continuous over 2 or more supports (minimum 3 span condition).
4. Stagger panel end joints. End joints shall only occur over a support. Unless recommended otherwise by the panel manufacturer, provide a 1/8" gap between panel ends and edges. Panel edges shall be tongue-and-groove or supported on 2" (nominal) lumber blocking installed between joists. Shear wall panel edges shall be supported on 2" (nominal) lumber blocking installed between studs.
5. See plans and schedules for roof and shear panel fastening requirements
METAL-PLATE-CONNECTED WOOD TRUSSES
1. Prefabricated wood trusses shall be detailed, fabricated and erected in accordance with the latest editions of the Timber Construction Manual by the American Institute of Timber Construction (AITC) and the National Design Specification for Wood Construction by the American Forest & Paper Association (ANSI/NFoPA NDS) and the latest criteria established by the Truss Plate Institute (TPI) and the Wood Truss Council of America (WTCA).
2. Temporary and permanent bracing of wood trusses shall be in accordance with the latest edition of the Commentary and Recommendations for Handling, Installing and Bracing Metal Plate Connected Wood Trusses (HIB) by the TPI.
3. Wood roof trusses shall be designed to support the following superimposed loads in addition to the weight of the trusses:
Top Chord Dead Load See loading plan on sheet S203Top Chord Live Load See loading plan on sheet S203Bottom Chord Dead Load 10 psfBottom Chord Live Load 0 psfTotal Load 40 psf
Wind Load (horizontal) per IBCWind Load (vertical) per IBC
4. Deflection due to live load shall be limited to 1/360 of the truss span. For truss cantilevers, the deflection due to live load at the end of the cantilever shall be limited to 1/180 of the cantilever dimension.
5. Truss plates shall be galvanized steel and shall be applied to both faces of the members being connected.
6. Trusses shall conform to the geometry shown. Minimum lumber size for top and bottom chord members shall be 2"x 6" (nominal). Web member size and configuration shall be the option of the fabricator.
7. The truss manufacturer shall prepare detailed working or shop drawings and shall submit one reproducible copy and one blue line copy, including calculations, to the Structural Engineer for review prior to fabrication. These drawings and calculations shall show the design forces in the truss members, the sizes of the truss plates; the lumber species, commercial grade and normal duration design values; required bracing and details necessary to enable the truss manufacturer to fabricate, erect and construct all parts of the work in accordance with the drawings and specifications. These shop drawings will be reviewed for design concepts only. The truss manufacturer shall be responsible for all dimensions, accuracy, and fit of work. The trusses shall be designed by, and the shop drawings and calculations shall bear the seal and signature of, a registered professional engineer in the State of Indiana.
8. The contractor shall install all permanent truss bracing as shown on the truss manufacturer's shop drawings.
COORDINATION WITH OTHER TRADES
1. The Contractor shall coordinate and check all dimensions relating to architectural finishes, structural framing, mechanical openings, equipment, etc. The Structural Engineer shall be notified of any discrepancies before proceeding with work in an area under question.
STRUCTURAL STEEL
1. Structural steel detailing, fabrication and erection shall conform to the latest editions of the AISC Specification for Structural Steel Buildings, Allowable Stress Design and Plastic Design and the AISC Code of Standard Practice for Steel Buildings and Bridges.
2. Erector shall maintain minimum temporary bracing at each bay in each direction until the roof diaphragm and permanent lateral load resisting system construction are complete.
3. Structural steel shall be shop-painted with a rust inhibiting primer. Steel which will be exposed to weather shall receive one additional finish coat. Steel that will be normally visible to the building's occupants or exposed to weather shall receive a field applied finish coat matching the existing surrounding surfaces. All abrasions caused by handling after shop painting shall be touched-up after erection is complete.
4. Design connections not shown in accordance with the latest AISC Specification and Manual of Steel Construction (allowable stress design method). Design simple span non-composite beam connections not shown to support one-half the beam load capacity as given in the AISC Uniform Load Constants for Beams Laterally Supported tables. Connection angles shall be double web angles, 5/16" minimum thickness.
5. Unless otherwise noted, bolted connections for structural steel members shall be bearing-type using 3/4" diameter ASTM A325 high strength bolts with standard 13/16" diameter holes tightened to the snug tight condition.
6. High strength bolted connections shall conform to the latest edition of the Specification for Structural Joints Using ASTM A325 or A490 Bolts, approved by the Research Council on Structural Connections of the Engineering Foundation. Faying surfaces of slip-critical-type (SC) connections shall be free of paint and meet the minimum requirements for a Class A surface condition (mean slip coefficient not less than 0.33).
7. Welding procedures shall conform to the latest edition of the American Welding Society's (AWS) Structural Welding Codes for: Steel ANSI/AWS D1.1 and Sheet Steel ANSI/AWS D1.3.
8. Welded connections using ASTM A572 and A992 steel as a base metal shall be made with E70XX Low Hydrogen electrodes. Unless otherwise noted, other welded connections shall be made with regular E70XX electrodes. Welding shall be performed only where shown and to the extent indicated.
9. Field drilled holes shall be reamed, cleaned and deburred prior to assembly of the connection.
10. Thermal cutting shall preferably be done by machine. Hand thermally cut edges which will be subjected to substantial stress, or which are to have weld metal deposited on them, shall be reasonably free from notches or gouges. Notches or gouges greater than 3/16" that remain from cutting shall be removed by grinding. Re-entrant corners shall be shaped notch-free to a radius of at least 1/2".
11. Paint on surfaces adjacent to joints to be field welded shall be wire brushed to reduce the paint film to a minimum.
12. Surfaces within 2" of any field weld shall be free of materials that would prevent proper welding or produce toxic fumes while welding is being done.
13. Splicing of structural steel members where not detailed is prohibited without the prior approval of the Structural Engineer as to location, type of splice and connection to be made.
14. The Contractor shall prepare detailed working or shop drawings to enable him to fabricate, erect and construct all parts of the work in accordance with the drawings and specifications and shall submit one reproducible copy and one blue line copy to the Structural Engineer for review prior to fabrication. These shop drawings will be reviewed for design concepts only. The Contractor shall be responsible for all dimensions, accuracy, and fit of work.
PETERSON ARCHITECTURE, P.C.
PETERSON ARCHITECTURE, P.C.
PROJECT NUMBER:
RIGHTS ARE HEREBY SPECIFICALLY RESERVED. ALL OTHER COPYRIGHT AND COMMON LAW
AND SHALL BE USED ONLY IN PURSUANT TO THE
NO OTHER USE OR DUPLICATION MAY BE MADE
THESE DRAWINGS ARE GIVEN IN CONFIDENCE
WITHOUT THE PRIOR WRITTEN CONSENT OF
AGREEMENT WITH
DRAWN BY:
CHECKED BY:
298 south 10th street
suite 500
noblesville in 46060
p 317.770.9714
f 317.770.9718
p e t e r s o n A R C H I T E C T U R E
CERTIFICATION
S101
JDT
MAH
17-112
04/14/2017
CONSTRUCTION DOCUMENTS
BLU
E W
AT
ER
BLU
E W
AT
ER
, LLC
NE
W C
ON
ST
RU
CT
ION
123 N
EW
JE
RS
EY
ST
RE
ET
IND
IAN
AP
OLIS
, IN
GENERAL STRUCTURAL NOTES
REVISIONS: DATE
7
S301 1
S301
2
S301
4
S301
5
S301
9
S301
6
S301
8
S301
3
S301
1
2
3
4
56
11
' - 0
1/4
"1
5' -
3"
11
' - 4
3/4
"
TS2
EXISTING FOOTING
EXISTING FOOTING
EXISTING 3'-0" X 3'-0" SPREAD FOOTING T/FTG. ELEV = - 0'-8"
78
HSS6X6X5/8HSS8X4X5/8
HSS6X6X5/8HSS8X4X5/8
HSS5X5X1/2
HSS5X5X1/2
TS2
3
S301
SIM.
7
EXISTING SLAB ON GRADE
EXISTING SLAB ON GRADE
EXISTING SLAB ON GRADE
EXISTING ELEVATED PRECAST PANEL FLOOR
SYSTEM
EXISTING BASEMENT WALL
EXISTING BASEMENT WALL
EXISTING BASEMENT WALL EXISTING
BASEMENT WALL
8 5/8" 5' - 0 3/8" 10' - 9"
EXISTING STEEL FRAMING
3" EOS
3"
EO
S
W12X16
11
S301
SEE NOTE 8
9' -
3"
3" EOS
EXISTING 3'-0" X 3'-0" SPREAD FOOTING T/FTG. ELEV = - 0'-8"
EXISTING 3'-0" X 3'-0" SPREAD FOOTING T/FTG. ELEV = - 1'-8"
EXISTING 3'-0" X 3'-0" SPREAD FOOTING T/FTG. ELEV = - 1'-8"
EXISTING 3'-0" X 3'-0" SPREAD FOOTING
T/FTG. ELEV = - 1'-8"
EXISTING 3'-0" X 3'-0" SPREAD FOOTING
T/FTG. ELEV = - 1'-8"
FOUNDATION PLAN NOTES
INDICATES NOTE REFERENCED IN PLAN
1. SEE GENERAL STRUCTURAL NOTES S101 AND TYPICAL FOUNDATION DETAILS S301 FOR ADDITIONAL INFORMATION.
2. T/SLAB ELEVATION = +0'-0" U.N.O.T/FOOTING ELEVATION = -0'-8" U.N.OT/STEEL ELEVATION = -0'4" U.N.O
3. SEE SITE PLAN FOR ALL FINAL GRADE ELEVATIONS. REFER TO THE CIVIL DRAWINGS FOR THE EXACT ELEVATION FOR THE FINISH FLOOR. ELEVATIONS SHOWN ON THE STRUCTURAL DRAWINGS DO NOT ESTABLISH THE EXACT ELEVATION OF THE BUILDING WITH RESPECT TO SEA LEVEL.
4. TSX DENOTES THICKENED SLAB MARK , SEE THICKENED SLAB SCHEDULE.
5. ALL EXTERIOR FOOTINGS ARE TO BEAR A MINIMUM 3'-0" BELOW FINISH GRADE.
6. ALL FOOTINGS ARE CENTERED BENEATH BEARING WALLS AND COLUMNS UNLESS NOTED OTHERWISE.
7. FLOOR DECK SHALL CONSIST OF 1-1/2", 22 ga. GALVANIZED, COMPOSITE STEEL FLOOR DECK (VULCRAFT DECK TYPE 1.5VLI22 OR APPROVED EQUIVALENT) WITH 2-1/2" OF N.W. CONCRETE OVER FLUTES (4" TOTAL THICKNESS). REINFORCE SLAB WITH ONE LAYER OF 6X6 - W1.4XW1.4 WWF REINFORCING. DECK MUST SPAN A MINIMUM THREE (3) BEAMS OR JOISTS - TWO SPAN CONDITION OR GREATER. FLOOR DECK SHALL BE WELDED TO ALL MEMBERS ON WHICH IT BEARS WITH 5/8" PUDDLE WELDS AT 16" O.C. MAX.
8. AT RE-ENTRANT SLAB CORNER CONDITIONS, PROVIDE (2) #5 x 4'-0" LONG AT 3-INCHES O.C. PLACED 2-INCHES CLEAR FROM CORNER, CENTERED IN SLAB, TYPICAL
9. DENOTES HOLDDOWN, SEE DETAIL 1/S401
THICKENED SLAB SCHEDULE
MARK WIDTH LENGTH THICK. BOTT. LONG. REINF. STIRRUPS
TS2 2'-0" CONT. 1'-0" 3 - #5 #4 AT 24" O.C.
STEEL COLUMN SCHEDULE
COLUMN SIZE BASE PLATE ANCHOR BOLTS REFERENCE
PL 1/2" X 12" X 12" HSS5X5X1/2 4 - 3/4" (EXISTING) -
PL 1/2" X 12" X 12" HSS6X6X5/8 4 - 3/4" (EXISTING) -
PL 1/2" X 12" X 12" HSS8X4X5/8 4 - 3/4" (EXISTING) -
PETERSON ARCHITECTURE, P.C.
PETERSON ARCHITECTURE, P.C.
PROJECT NUMBER:
RIGHTS ARE HEREBY SPECIFICALLY RESERVED. ALL OTHER COPYRIGHT AND COMMON LAW
AND SHALL BE USED ONLY IN PURSUANT TO THE
NO OTHER USE OR DUPLICATION MAY BE MADE
THESE DRAWINGS ARE GIVEN IN CONFIDENCE
WITHOUT THE PRIOR WRITTEN CONSENT OF
AGREEMENT WITH
DRAWN BY:
CHECKED BY:
298 south 10th street
suite 500
noblesville in 46060
p 317.770.9714
f 317.770.9718
p e t e r s o n A R C H I T E C T U R E
CERTIFICATION
S201
JDT
MAH
17-112
04/14/2017
CONSTRUCTION DOCUMENTS
BLU
E W
AT
ER
BLU
E W
AT
ER
, LLC
NE
W C
ON
ST
RU
CT
ION
123 N
EW
JE
RS
EY
ST
RE
ET
IND
IAN
AP
OLIS
, IN
FIRST FLOOR LEVEL FOUNDATION,SLAB-ON-GROUND & FRAMING PLAN
3/16" = 1'-0"S201
1 FOUNDATION / SLAB-ON-GROUND PLAN
REVISIONS: DATE
1
2
3
4
56
1
S402
7
S402
6
S402
4
S402
2
S402
5
S402
11
' - 0
1/4
"1
5' -
3"
11
' - 4
3/4
"
8 5/8" 5' - 0 3/8" 10' - 9"
S501
11
S402
WOOD TRUSSES AT 24" O.C. MAX
H-4H-2HL-1H-2H-2
A
A
C
C
H-3B
6
S402
2X BLOCKING BETWEEN ROOF TRUSSES, TYP.
S501
2
78
CANOPY(LOW STEEL)
CANOPY(HIGH STEEL)
3
S402
4X4 BLOCKING BETWEEN TRUSSES,SEE DETAIL 1/S502 FOR STRAPPING REQUIRES
15' MINIMUM
8
S402
4X4 BLOCKING BETWEEN TRUSSES,SEE DETAIL 1/S502 FOR STRAPPING REQUIRES
15' MINIMUM
2X BLOCKING AND BRIDGING BETWEEN
ROOF TRUSSES, TYP.
SEE DETAIL 5/S502 FOR STRAPPING REQUIRES
SEE DETAIL 5/S502 FOR STRAPPING REQUIRES
SW1
SW1
ROOF FRAMING PLAN NOTES:
INDICATES NOTE REFERENCED ON PLAN
1. SEE GENERAL STRUCTURAL NOTES S001AND TYPICAL FRAMING DETAILS S401 FOR ADDITIONAL INFORMATION.
2. TOP PLATE HEIGHTS MAY VARY. SEE PLAN, SECTIONS AND TRUSS ELEVATIONS FOR BEARING HEIGHTS.
3. TRUSS BEARING ELEVATION = +12'-0" UNLESS NOTED OTHERWISE
4. REFER TO ARCHITECTURAL ROOF PLAN FOR CONFIGURATION OF VENTS ON BUILDING.
5. ROOF DECK SHALL BE APA 32/16 SPAN RATED SHEATHING, 5/8-INCH NOMINAL THICKNESS, EXPOSURE 1. ATTACH WITH 8d COMMON NAILS AT 12-INCHES O.C. IN FIELD AND 6-INCHES O.C. AT EDGES AND DIAPHRAGM BOUNDARIES, UNLESS NOTED OTHERWISE ON PLANS. PROVIDE SHEATHING SUPPORT CLIPS BETWEEN TRUSSES AT UNBLOCKED PANEL EDGES (SIMPSON PSCL OR EQUAL)
6. PROVIDE BLOCKING IN ROOF TRUSSES AT EXTERIOR WALL LOCATIONS AS INDICATED ON PLANS AND SECTIONS.
7. SEE ARCH. FOR WALL LAYOUT DIMENSIONS.
8. DENOTES WOOD HEADER/BEAM - SEE SCHEDULE ON THIS SHEET.
9. PROVIDE LAMINATED VENEER LUMBER (LVL) BEAMS IN SIZES INDICATED ON PLANS AND HEADER SCHEDULE.
10. PROVIDE BRICK LINTELS AS FOLLOWS UNLESS NOTED OTHERWISE:FOR SPANS ≤ 4'-0": L 3 1/2 x 3 1/2 x 3/8FOR SPANS > 4'-0", ≤ 6'-0": L 5 1/2 x 3 1/2 x 3/8 (LLV)FOR SPANS > 6'-0", ≤ 8'-0": L 6 1/2 x 3 1/2 x 3/8 (LLV)FOR SPANS > 8'-0", ≤ 12'-0": L 7 1/2 x 4 x 3/8 (LLV)
ALL BRICK LINTELS TO HAVE 8 INCHES BEARING, EACH END.
WALL FRAMING PLAN NOTES
INDICATES NOTE REFERENCED IN PLAN
A. SEE GENERAL STRUCTURAL NOTES S001 AND TYPICAL FRAMING DETAILS S401 FOR ADDITIONAL INFORMATION.
B. WALLS SHOWN ARE 1ST FLOOR BEARING BELOW. SHADED WALLS ARE SHEARWALLS.
C. ALL EXTERIOR WALLS TO BE SHEATHED WITH APA 32/16 SPAN RATED PLYWOOD, 5/8" NOMINAL THICKNESS ATTACHED WITH 8D COMMON NAILS AT 12-INCH O.C. IN FIELD AND 6 INCHES O.C AT ALL EDGES AND BOUNDARIES, U.N.O. ON SHEAR WALL SCHEDULE. SEE PLAN, SCHEDULE, AND DETAILS FOR SHEATHING REQUIREMENTS ON SHEAR WALLS.
D. HEADERS IN NON-BEARING WALLS SHALL BE DOUBLE 2X MEMBERS AS FOLLOWS W/ 1/2" FILLER PLATE SPLICES.
ALL HEADER STOCK FOR NON-LOAD BEARING WALLS TO BE SPF CONSTRUCTION GRADE.
E. ALL HEADERS NOT ABOVE DOORS OR WINDOWS ARE TO BE FLUSH WITH CEILING
DENOTES BEARING WALLS - SEE SCHEDULE ON THIS SHEET
DENOTES SHEAR WALL - SEE SCHEDULE ON THIS SHEET
SPAN 2x4 WALL 2x6 WALL JACK STUDS
0'-0" TO 4'-0" (2) 2x4 (3) 2x4 1
4'-1" TO 8'-0" (2) 2x6 (3) 2x6 1
8'-1" TO 12'-0" (2) 2x8 (3) 2x8 2
KING STUDS
1
1
1
WOOD STUD WALL SCHEDULE
A
B
2x6 SP #2 @ 16" O.C.
2x4 SP #2 @ 16" O.C.
WOOD NOTES:1. REFER TO ARCH. PLANS FOR WALL LOCATIONS.2. WALLS SHOWN ARE BEARING WALLS BELOW.
C
2x4 (2-PLY) SP #2 @ 12" O.C.
WOOD HEADER/BEAM SCHEDULE
H-1
H-2
(3) 2 x 10 (SP NO. 2 OR BETTER) W/ 1/2" FILLER PLATE SPLICES
(3) 1 3/4" X 9 1/4" 2.0E MICROLLAM LVL
MARK HEADER/BEAM SIZE
H-3 (2) 1 3/4" X 14" 2.0E MICROLLAM LVL
H-4 (3) 1 3/4" X 14" 2.0E MICROLLAM LVL
JACK STUDS
1
KING STUDS
1
2 1
3 1
3 1
WOOD STUD SHEAR WALL SCHEDULE
SW1 2x6 SP #2 @ 16" O.C.
WOOD NOTES:1. REFER TO ARCH. PLANS FOR WALL LOCATIONS.2. WALLS SHOWN ARE BEARING WALLS BELOW. 3. SEE DETAIL 1/S401 FOR SHEAR WALL NAILING REQUIREMENTS
PETERSON ARCHITECTURE, P.C.
PETERSON ARCHITECTURE, P.C.
PROJECT NUMBER:
RIGHTS ARE HEREBY SPECIFICALLY RESERVED. ALL OTHER COPYRIGHT AND COMMON LAW
AND SHALL BE USED ONLY IN PURSUANT TO THE
NO OTHER USE OR DUPLICATION MAY BE MADE
THESE DRAWINGS ARE GIVEN IN CONFIDENCE
WITHOUT THE PRIOR WRITTEN CONSENT OF
AGREEMENT WITH
DRAWN BY:
CHECKED BY:
298 south 10th street
suite 500
noblesville in 46060
p 317.770.9714
f 317.770.9718
p e t e r s o n A R C H I T E C T U R E
CERTIFICATION
S202
JDT
MAH
17-112
04/14/2017
CONSTRUCTION DOCUMENTS
BLU
E W
AT
ER
BLU
E W
AT
ER
, LLC
NE
W C
ON
ST
RU
CT
ION
123 N
EW
JE
RS
EY
ST
RE
ET
IND
IAN
AP
OLIS
, IN
ROOF FRAMING PLAN
3/16" = 1'-0"S202
1 ROOF FRAMING PLAN
REVISIONS: DATE
28
' - 0
"
22' - 0"
4' -
0"
15
' - 3
"4
' - 0
"7
' - 9
"
10' - 6" 9' - 0"
ROOF TRUSS (TOP CHORD) LOADING LEGEND:
DEAD LOAD: 10 PSF SNOW LOAD: 25 PSF
DEAD LOAD: 10 PSF SNOW LOAD: 60 PSF
DEAD LOAD: 70 PSF SNOW LOAD: 45 PSF
+/-
14
' - 6
"+
/- 1
9' -
8"
TR
US
S S
PA
N 3
TR
US
S S
PA
N 2
+/-
34
' - 2
"
TR
US
S S
PA
N 1
+/-
39
' - 5
"
+/-
11
' - 9
"+
/- 1
2' -
5"
TR
US
S
SP
AN
4T
RU
SS
S
PA
N 5
+/- 39' - 5"
2' -
10
"
2' -
0"
TRUSS BRG.
= +12'-0"
SEE LOADING PLAN FOR TOP CHORD LOADING
BOTTOM CHORD SUPPORT LOCATION
BOTTOM CHORD SUPPORT LOCATION
SEE OTHER SECTIONS FOR HOLDDOWN REQUIREMENTS
+/- 34 - 2"
TRUSS BRG.
= +12'-0"
2' -
0"
SEE LOADING PLAN FOR TOP CHORD LOADING
BOTTOM CHORD SUPPORT LOCATION
BOTTOM CHORD SUPPORT LOCATION
SEE OTHER SECTIONS FOR HOLDDOWN REQUIREMENTS2
' - 1
0"
+/- 14' - 6" +/- 19' - 8"
TRUSS BRG.
= +12'-0"
2' -
0"
SEE LOADING PLAN FOR TOP CHORD LOADING
BOTTOM CHORD SUPPORT LOCATION
BOTTOM CHORD SUPPORT LOCATION
BOTTOM CHORD SUPPORT LOCATION
SEE OTHER SECTIONS FOR HOLDDOWN REQUIREMENTS2
' - 1
0"
+/- 11' - 9"
TRUSS BRG.
= +12'-0"
SEE LOADING PLAN FOR TOP CHORD LOADING
BOTTOM CHORD SUPPORT LOCATION
TOP CHORD SUPPORT LOCATION
SEE OTHER SECTIONS FOR HOLDDOWN REQUIREMENTS2
' - 1
0"
2' -
0"
7"
+/- 12' - 5"
TRUSS BRG.
= +12'-0"
2' -
0"
SEE LOADING PLAN FOR TOP CHORD LOADING
BOTTOM CHORD SUPPORT LOCATION
TOP CHORD SUPPORT LOCATION
SEE OTHER SECTIONS FOR HOLDDOWN REQUIREMENTS
1' -
8"
7"
PETERSON ARCHITECTURE, P.C.
PETERSON ARCHITECTURE, P.C.
PROJECT NUMBER:
RIGHTS ARE HEREBY SPECIFICALLY RESERVED. ALL OTHER COPYRIGHT AND COMMON LAW
AND SHALL BE USED ONLY IN PURSUANT TO THE
NO OTHER USE OR DUPLICATION MAY BE MADE
THESE DRAWINGS ARE GIVEN IN CONFIDENCE
WITHOUT THE PRIOR WRITTEN CONSENT OF
AGREEMENT WITH
DRAWN BY:
CHECKED BY:
298 south 10th street
suite 500
noblesville in 46060
p 317.770.9714
f 317.770.9718
p e t e r s o n A R C H I T E C T U R E
CERTIFICATION
S203
JDT
NDB
17-112
BLU
E W
AT
ER
BLU
E W
AT
ER
, LLC
123 N
EW
JE
RS
EY
ST
RE
ET
IND
IAN
AP
OLIS
, IN
TRUSS LOADING PLAN AND PROFILES
1/16" = 1'-0"S203
1 ROOF TRUSS TOP CHORD LOADING PLAN
3/8" = 1'-0"S203
2 TRUSS SPAN 1
3/8" = 1'-0"S203
3 TRUSS SPAN 2
3/8" = 1'-0"S203
4 TRUSS SPAN 3
3/8" = 1'-0"S203
5 TRUSS SPAN 4
3/8" = 1'-0"S203
6 TRUSS SPAN 5
REVISIONS: DATE
T/SLAB EL.
SEE PLANT/STEEL EL.
SEE PLAN
EXISTING BRICK WALL
EXISTING CONCRETE
EXISTING MASONRY
BEARING WALL, SEE PLANS
EXISTING BEAM
COMPOSITE CONCRETE SLAB ON METAL DECK, SEE PLAN FOR REINFORCEMENT REQUIREMENTS
SE
E P
LA
N
1/2" ANCHORS AT 24" O.C. (3" EMBED) W/ 3X3
BEARING PLATE
#4, CONT.
T/SLAB EL.
SEE PLAN
T/FTG EL.
SEE PLAN
EXISTING SLAB
EXISTING FOOTING
BEARING WALL, SEE PLANS
EXISTING MASONRY WALL
1/2" ANCHORS AT 16" O.C. W/ SIMPSON 3X3 BEARING PLATE
FULLY GROUT CORES OF BELOW GRADE CMU FOUNDATION WALL
T/SLAB EL.
SEE PLAN
T/FTG EL.
SEE PLAN
EXISTING SLAB
EXISTING FOOTING
BEARING WALL, SEE PLANS
EXISTING MUD SLAB
EXISTING INSULATION
EXISTING MASONRY WALL
1/2" EXPANSION JOINT
8"
#4 AT 12" O.C., E.W.
#4 DOWEL AT 12" O.C., EMBED INTO EXISTING CMU WALL
USING HILTI HY 70 ADHESIVE SYSTEM (4" EMBED)
1/2" ANCHORS AT 12" O.C. (6" EMBED) W/ SIMPSON
3X3 BEARING PLATE
#4 AT 12" O.C., E.W.
T/SLAB EL.
SEE PLAN
T/FTG EL.
SEE PLAN
EXISTING SLAB
EXTERIOR STUD WALL, SEE PLANS
EXISTING FOOTING
EXISTING MASONRY WALL
1/2" ANCHORS AT 16" O.C. (3" EMBED) W/ SIMPSON 3X3 BEARING PLATE
FULLY GROUT CORES OF BELOW GRADE CMU FOUNDATION WALL
WALL SHEATHING, SEE PLAN
SEE ARCH. DWGS. FOR WALL AND ROOF FINISHES
T/SLAB EL.
SEE PLAN
EXISTING SLAB
EXISTING BRICK WALL
EXISTING TOPPING SLAB
EXISTING CONCRETE
EXISTING PRECAST PLANK
EXTERIOR STUD WALL, SEE PLANS
EXISTING INSULATION
1/2" HILTI KWIK BOLT TZ ANCHORS AT 12" O.C. (4" EMBED) W/ SIMPSON 3X3 BEARING PLATE
WALL SHEATHING, SEE PLAN
SEE ARCH. DWGS. FOR WALL AND ROOF FINISHES
T/STEEL EL.
SEE PLAN
EXISTING BEAM
EXISTING TOPPING SLAB
EXISTING INSULATION
EXISTING PRECAST PLANK
EXTERIOR STUD WALL, SEE PLANS SEE ARCH. DWGS.
FOR WALL AND ROOF FINISHES
COMPOSITE CONCRETE SLAB ON METAL DECK, SEE PLAN FOR REINFORCEMENT REQUIREMENTS
SE
E P
LA
N
WALL SHEATHING, SEE PLAN
1/2" ANCHORS AT 24" O.C. (3" EMBED) W/ SIMPSON 3X3 BEARING PLATE
#4, CONT.
T/SLAB EL.
SEE PLAN
COMPOSITE CONCRETE SLAB ON METAL DECK, SEE PLAN FOR REINFORCEMENT REQUIREMENTS
EXISTING BRICK WALL
EXISTING SLAB
EXISTING CONCRETE
SE
E P
LA
N
1/2" EXPANSION JOINT
T/SLAB EL.
SEE PLANT/STEEL EL.
SEE PLAN
EXISTING BRICK WALL
EXISTING CONCRETE
EXISTING SLAB
EXISTING MUD SLAB
EXISTING INSULATION
COMPOSITE CONCRETE SLAB ON METAL DECK, SEE PLAN FOR REINFORCEMENT REQUIREMENTS
1/2" EXPANSION JOINT
T/SLAB EL.
SEE PLAN
EXISTING SLAB
WALL SHEATHING, SEE PLAN
THICKENED SLAB, SEE PLAN
BEARING WALL, SEE PLAN
3"
CLR
.
WIDTH 'B', SEE PLAN
TH
ICK
NE
SS
'T',
SE
E P
LA
N
1/2" ANCHORS AT 12" O.C. (6" EMBED) W/ SIMPSON 3X3 BEARING PLATE
SEE SCHD.S
EE
SC
HD
.
NOTE TO CONTRACTOR:REMOVE EXISTING COLUMN, BASE PLATE, AND GROUT BENEATH BASE PLATE. EXISTING ANCHOR RODS EMBEDDED INTO COLUMN FOOTING SHALL BE PROTECTED IN PLACE AND CLEANED PRIOR TO INSTALLATION OF NEW BASE PLATE.
HSS COLUMN, SEE PLAN
BASE PLATE, SEE SCHEDULE
EQ EQ
EQ
EQ
(4) EXISTING 3/4" DIAMETER ANCHOR BOLTS
1/4
(4) OVERSIZED HOLES, VERIFY EXISTING ANCHOR LOCATIONS PRIOR TO FABRICATION OF BASE PLATE
MIN.1 1/4" M
IN.
1 1
/4"
BEAM, SEE PLAN
EOS, SEE PLAN
T/STEEL EL.
SEE PLAN
COMPOSITE CONCRETE SLAB ON METAL DECK, SEE PLAN FOR REINFORCEMENT REQUIREMENTS
T/SLAB EL.
SEE PLAN
PETERSON ARCHITECTURE, P.C.
PETERSON ARCHITECTURE, P.C.
PROJECT NUMBER:
RIGHTS ARE HEREBY SPECIFICALLY RESERVED. ALL OTHER COPYRIGHT AND COMMON LAW
AND SHALL BE USED ONLY IN PURSUANT TO THE
NO OTHER USE OR DUPLICATION MAY BE MADE
THESE DRAWINGS ARE GIVEN IN CONFIDENCE
WITHOUT THE PRIOR WRITTEN CONSENT OF
AGREEMENT WITH
DRAWN BY:
CHECKED BY:
298 south 10th street
suite 500
noblesville in 46060
p 317.770.9714
f 317.770.9718
p e t e r s o n A R C H I T E C T U R E
CERTIFICATION
S301
JDT
MAH
17-112
04/14/2017
CONSTRUCTION DOCUMENTS
BLU
E W
AT
ER
BLU
E W
AT
ER
, LLC
AD
DI T
ION
S A
ND
RE
NO
VA
TI O
NS
123 N
EW
JE
RS
EY
ST
RE
ET
IND
IAN
AP
OLIS
, IN
FOUNDATION SECTIONS & DETAILS
1" = 1'-0"S301
7 SECTION 1" = 1'-0"S301
1 SECTION
1" = 1'-0"S301
2 SECTION
1" = 1'-0"S301
4 SECTION
1" = 1'-0"S301
5 SECTION
1" = 1'-0"S301
9 SECTION 1" = 1'-0"S301
6 SECTION
1" = 1'-0"S301
8 SECTION
1" = 1'-0"S301
3 SECTION
1 1/2" = 1'-0"S301
10 BASE PLATE DETAIL
1" = 1'-0"S301
11 SECTION
REVISIONS: DATE
2-PLY CONDITION
BUILT-UPSTUD PACK, SEE PLAN
(2) ROWS OF
1/2" DIA. A306
THRU BOLTS,
STAGGERED
(2) ROWS OF16d NAILS,STAGGERED,TYPICALEACH SIDEOF BUILT-UPCOLUMN
(2) ROWS OF10d NAILS,STAGGERED.
BUILT-UPSTUD PACK, SEE PLAN
BUILT-UPSTUD PACK,SEE PLAN
VE
RT
.S
PA
CIN
G
TY
P.
* BOLTS SHOWN IN 4 & 5 PLY CONDITION MAY BE CARRIAGE BOLTS.
4/5-PLY CONDITION 3-PLY CONDITION
2 1
/2"
8"
O.C
.
1 1/2"
2 1/2"
1 1/2"
VE
RT
.S
PA
CIN
G
TY
P.
8"
O.C
.
VE
RT
.S
PA
CIN
G
6"
O.C
.
1 1/2"
2 1/2"
1 1/2" 1 1/2"
2 1/2"
1 1/2"
2 1
/2"
4"
WOOD HEADER, SEEPLAN AND SCHED.
16d NAILS AT 12" O.C.,STAGGERED - BOTH SIDES
2x PLATE
(2) 2x TOP PLATES
WALL STUDS, SEE PLAN
JACK STUDS, SEEPLAN AND SCHED.
BRG. EL.
SEE PLAN
TRUSS
OPENING
KING STUDS, SEEPLAN AND SCHED.
(2) #5, CONT.
#4 AT 16" O.C. DOWEL, PROVIDE ACI STD. HOOK, EMBED INTO EXISTING GROUTED CELLS BELOW USING HILTI-HY 200 ADHESIVE SYSTEM (EMBED 4")
ADDITION CMU BOND BEAM COURSE, MATCH THICKNESS
OF EXISTING WALL
EXISTING CMU WALL
T/WALL
VARIES
T/WALL (EXT)
VARIES
RIP 2x No. 2 SPNAILER TO TOPOF STEEL BEAM
STEEL BEAM,SEE PLAN
ATTACH WOOD NAILER TO
STEEL BEAM WITH 1/2" DIA.
A307 THRU BOLTS AT
24" O.C.,STAGGERED AT
BEAM FLANGE GAGE. 2' -
0"
2' -
0"
1' -
0"
1' -
0"
2-ROWS OF 10d NAILS,STAGGERED. (8) NAILS
MINIMUM. (TYP.)
TOP PLATESPLICE AT STUD
WOOD STUDS,SEE PLAN
BOTT. PLATESPLICE AT STUD
APPLY GLUE THISSURFACE(LAP AREA ONLY)
(2) 16d NAILSPER STUD
DOUBLE TOPPLATE
4'-0" MIN. LAP
PROVIDE DOUBLE STUDSAT ENDS OF ALL SHEARWALLS.
2x INTERMEDIATEBLOCKING
APA RATED SHEATHING
16" O.C. STUD WALL
EDGE/BOUNDARY NAILING,SEE PLAN AND SCEDULE
INTERMEDIATE/FIELDNAILING, SEE PLAN
AND SCHEDULE
E FSCREWS
B
SPA. IN INCHESBLK'G REQ'D
SIDES
SHEARWALL SCHEDULE
MARK
NOTES:1. B = BOUNDARY, E = EDGE, F = FIELD2. PLYWOOD SHALL BE APA 32/16 SPAN RATED SHEATHING, FIRE RATED, EXPOSURE 1. SEE SCHEDULE FOR THICKNESS.3. INTERIOR SHEATHING SHALL BE 5/8" GYPSUM BOARD WITH BLOCKED CONSTRUCTION AND 6d COOLER NAILS AT 7" O.C. AT
BOUNDARIES, EDGES AND FIELD, TYPICAL UNO.
MATERIAL SILL BOLTS/NAILS TIE DOWNS, EACH END
SW1 5/8" PLYWOOD 1 YES #8 6 6 12 1/2" HILTI HCA
COIL ANCHORS
AT 24" O.C.
SIMPSON HDU8-SDS2.5 EACH END
(REF. DETAIL ) /3 S401
LGM STUDS
FOUNDATION WALL,SEE PLANS AND
SECTIONS CONT. LGM STRUCTURAL TRACK
1/4" x 3" x 0'-3" WASHER PLATE
AND DOUBLE NUTS A307 ANCHOR BOLT
FASTENERS
SIMPSON HOLDOWN (ORAPPROVED EQUAL), INSTALL PERMANUFACTURER'SRECOMMENDATIONS
LGM FLANGE NOTSHOWN FOR CLARITY
1 1
/2"
PR
OJ.
4"
PETERSON ARCHITECTURE, P.C.
PETERSON ARCHITECTURE, P.C.
PROJECT NUMBER:
RIGHTS ARE HEREBY SPECIFICALLY RESERVED. ALL OTHER COPYRIGHT AND COMMON LAW
AND SHALL BE USED ONLY IN PURSUANT TO THE
NO OTHER USE OR DUPLICATION MAY BE MADE
THESE DRAWINGS ARE GIVEN IN CONFIDENCE
WITHOUT THE PRIOR WRITTEN CONSENT OF
AGREEMENT WITH
DRAWN BY:
CHECKED BY:
298 south 10th street
suite 500
noblesville in 46060
p 317.770.9714
f 317.770.9718
p e t e r s o n A R C H I T E C T U R E
CERTIFICATION
S401
JDT
NDB
17-112
04/14/2017
CONSTRUCTION DOCUMENTS
BLU
E W
AT
ER
BLU
E W
AT
ER
, LLC
NE
W C
ON
ST
RU
CT
ION
123 N
EW
JE
RS
EY
ST
RE
ET
IND
IAN
AP
OLIS
, IN
FRAMING SECTIONS & DETAILS
1" = 1'-0"S401
6 BUILT-UP WOOD COLUMN
3/8" = 1'-0"S401
5 TYPICAL HEADER LAYOUT 1 1/2" = 1'-0"S401
8 CMU COURSE ADDITION
3/4" = 1'-0"S401
7 TYPICAL WOOD NAILER ATTACHMENT 3/4" = 1'-0"S401
4 TYPICAL DOUBLE TOP PLATE SPLICE 1" = 1'-0"S401
2 TYP. SHEAR WALL NAILING PATTERN
3/4" = 1'-0"S401
1 SHEARWALL SCHEDULE
1" = 1'-0"S401
3 TYPICAL HOLDDOWN DETAIL
REVISIONS: DATE
ROOF SHEATHING, SEE PLAN
BEARING WALL, SEE PLAN
DOUBLE TOP PLATE
WOOD ROOF TRUSSES, SEE PLAN
EXISTING CMU WALL, SEE PLAN
TRUSS BRG.
= +12'-0"
T/WALL
= + 16' - 0"
T/WALL (EXT)
= + 15' - 4"
SEE DETAIL 8/S401 FOR TOP CMU COURSE ADDITION
SEE ARCH. DWGS. FOR WALL AND ROOF FINISHES
SIMPSON H10A TIE AT EACH END OF ROOF TRUSS, TYP.
3/8" HILTI SLEEVE ANCHORS AT 16" O.C.
(1-1/4" EMBED)
B.N.
2X BLOCKING BTWN TRUSSES
WOOD ROOF TRUSSES, SEE PLAN
ROOF SHEATHING, SEE PLAN
BEARING WALL, SEE PLAN
DOUBLE TOP PLATE
TRUSS BRG.
= + 12' - 0"
SEE ARCH. DWGS. FOR ROOF FINISHES
SIMPSON H10A TIE AT EACH END OF
ROOF TRUSS, TYP.
WALL SHEATHING, SEE PLANS
B.N.
2X BLOCKING BTWN TRUSSES
B.N.
SIMPSON A34 CLIP AT 24" O.C.
SHEATHING AND NAILING SAME AS SHEAR WALL
ROOF SHEATHING, SEE PLAN
(2) 2X8 LEDGER BEAM
WOOD ROOF TRUSSES, SEE PLAN
EXISTING CMU WALL, SEE PLAN
TRUSS BRG.
= +12'-0"
T/WALL
= + 16' - 0"
T/WALL (EXT)
= + 15' - 4"
SEE DETAIL 8/S401 FOR TOP CMU COURSE ADDITION
SEE ARCH. DWGS. FOR WALL AND ROOF FINISHES
3/8" HILTI SLEEVE ANCHORS AT 16" O.C.
(1-1/4" EMBED)
B.N.
2X BLOCKING BTWN TRUSSES
1/2" HILTI SLEEVE ANCHORS AT 8" O.C.
STAGGERED(1-1/2" EMBED)
SIMPSON H10A TIE AT EACH END OF ROOF TRUSS, TYP.
WOOD ROOF TRUSSES, SEE PLAN
TRUSS BRG.
= + 12' - 0"
T/WALL
= + 16' - 0"
SEE ARCH. DWGS. FOR WALL AND ROOF FINISHES
DOUBLE TOP PLATE
WALL SHEATHING, SEE PLANS
ROOF SHEATHING, SEE PLANS
DOUBLE TOP PLATE
EXTERIOR BEARING WALL, SEE PLAN
SIMPSON H10A TIE AT EACH END OF ROOF TRUSS, TYP.
B.N.
B.N.
2X BLOCKING BTWN TRUSSES
SIMPSON A34 CLIP AT 24" O.C.
2X BLOCKING BTWN TRUSSES
STUDS BETWEEN TRUSSES, MATCH TRUSS SPACING
WOOD ROOF TRUSSES, SEE PLAN
ROOF SHEATHING, SEE PLAN
EXISTING CMU WALL, SEE PLAN
TRUSS BRG.
= + 12' - 0"
T/WALL
= + 16' - 0"
T/WALL (EXT)
= + 15' - 4"
SEE DETAIL 8/S401 FOR TOP CMU COURSE ADDITION
SEE ARCH. DWGS. FOR WALL AND ROOF FINISHES
NON-LOAD BEARING STUD WALL, SEE ARCH. DWGS.
2X BLOCK BTWN EXTERIOR WALL AND 2 ROOF TRUSSES
1' MAX
SIMPSON LTB TRUSS BRIDGING, INSTALL IN 2 FULL TRUSS SPACES AS SHOWN
3/8" HILTI SLEEVE ANCHORS AT 16" O.C.
(1-1/4" EMBED)
B.N.
SIMPSON A34 FRAMING ANGLE
2X, CONT.
WOOD ROOF TRUSSES, SEE PLAN
TRUSS BRG.
= + 12' - 0"
T/WALL
= + 16' - 0"
SEE ARCH. DWGS. FOR WALL AND ROOF FINISHES
EXTERIOR STUD WALL, SEE PLANS
DOUBLE TOP PLATE
WALL SHEATHING, SEE PLANS
ROOF SHEATHING, SEE PLANS
2X BLOCK BTWN WOOD ROOF TRUSS
B.N.
B.N.
SIMPSON A34 FRAMING ANGLE
2X BLOCKING BTWN TRUSSES
TRUSS BRG.
= +12' - 0"
EXISTING CMU WALL, SEE PLAN
ROOF SHEATHING, SEE PLAN
SEE ARCH. DWGS. FOR ROOF FINISHES
T/WALL (EXT)
= +11' - 4"
WOOD ROOF TRUSSES, SEE PLAN
T/WALL
= +11' - 10"
SIMPSON LTB TRUSS BRIDGING, INSTALL IN 3 TRUSS SPACES AS SHOWN
2X6 BLOCKING AT 2'-0" O.C.
L4X4X1/4 X 1'-4" LONG, EACH SIDE OF 2X6 BLOCKING
(3) 1/2" DIA. BOLTS
6" CMU, SEE DETAIL 8/S401 FOR TOP CMU COURSE ADDITION
L4X4X1/4, CONT.
2"
TRUSS BRG.
= +12' - 0"
EXISTING CMU WALL, SEE PLAN
ROOF SHEATHING, SEE PLAN
SEE ARCH. DWGS. FOR ROOF FINISHES
T/WALL (EXT)
= +11' - 4"
WOOD ROOF TRUSSES, SEE PLAN
T/WALL
= +11' - 10"
L4X4X1/4 X 1'-4" LONG, EACH SIDE TRUSS CHORD
(3) 1/2" DIA. BOLTS
6" CMU, SEE DETAIL 8/S401 FOR TOP CMU COURSE ADDITION
L4X4X1/4, CONT.
2"
PETERSON ARCHITECTURE, P.C.
PETERSON ARCHITECTURE, P.C.
PROJECT NUMBER:
RIGHTS ARE HEREBY SPECIFICALLY RESERVED. ALL OTHER COPYRIGHT AND COMMON LAW
AND SHALL BE USED ONLY IN PURSUANT TO THE
NO OTHER USE OR DUPLICATION MAY BE MADE
THESE DRAWINGS ARE GIVEN IN CONFIDENCE
WITHOUT THE PRIOR WRITTEN CONSENT OF
AGREEMENT WITH
DRAWN BY:
CHECKED BY:
298 south 10th street
suite 500
noblesville in 46060
p 317.770.9714
f 317.770.9718
p e t e r s o n A R C H I T E C T U R E
CERTIFICATION
S402
JDT
NDB
17-112
BLU
E W
AT
ER
BLU
E W
AT
ER
, LLC
123 N
EW
JE
RS
EY
ST
RE
ET
IND
IAN
AP
OLIS
, IN
FRAMING SECTIONS & DETAILS
3/4" = 1'-0"S402
1 SECTION
3/4" = 1'-0"S402
2 SECTION
3/4" = 1'-0"S402
3 SECTION
3/4" = 1'-0"S402
4 SECTION
3/4" = 1'-0"S402
5 SECTION
3/4" = 1'-0"S402
6 SECTION
3/4" = 1'-0"S402
8 SECTION
3/4" = 1'-0"S402
7 SECTION
REVISIONS: DATE
5678
10' - 9"5' - 0 3/8"8 5/8"
1' - 9 5/8"
3/4"
S502
1
S501
5
S501
6
S501
7
S501
8
T/STEEL
= + 11' - 3 1/2"
T/STEEL
= + 19' - 9"
T/STEEL
= + 28' - 1"
T/STEEL
= + 28' - 2"
S502
2
SEE ARCH. DWGS. FOR WOOD OVER-BUILD MEMBER SIZES AND DETAILING
S502
3
T/STEEL
SEE PLAN
5
S502
1
2
3
4
56
3
S501
11
' - 0
1/4
"1
5' -
3"
11
' - 4
3/4
"
5' - 0 3/8" 10' - 9"
W12X26
W12X26
W12X26
C1
2X
20
.7
W12X26
W12X26
2' - 2"
7
STEEL ROD X-BRACING ABOVE
BEAM (ø = 1/2")
STEEL ROD X-BRACING ABOVE BEAM (ø = 1/2")
(T/STEEL = +13' - 8")
TOP OF STEEL = +11' - 3 1/2" UNLESS NOTED OTHERWISE
W12
X16
W12X26
W12X26
HSS4X4X1/4
HSS4X4X1/4
HSS4X4X1/4
(T/STEEL = +14' - 0")
C1
2X
20
.7
S502
6
TYP.
8
S502
C1
2X
20
.7C
12X
20
.7
(T/S
TE
EL
= +
13 -
10
")
ø =
3/8
"ø = 3/8"
ø =
3/8
"ø = 3/8"
1' -
8 3
/4"
C12X20.7
C12X20.71' -
10
1/2
"
5
S502
HSS TUBE BRACE BELOW, SEE SECTION
HSS TUBE BRACE BELOW, SEE SECTION
AT BRACE
2
3
56
3
S501
15
' - 3
"
5' - 9" 10' - 9"
W12
X16
C1
2X
20
.7
C1
2X
20
.7
(T/S
TE
EL
= +
28
' - 1
")
(T/S
TE
EL
= +
19
' - 9
")
(T/S
TE
EL
= +
28
' - 2
")
W12X16W10X15
8
STEEL ROD X-BRACING, TYP.
STEEL ROD X-BRACING BENEATH BEAM(ø = 1/2")
STEEL ROD X-BRACING
BENEATH BEAM(ø = 1/2")
W12X16
W10X15
W10X15
S502
6
SIM. TYP.
ø =
3/8"ø = 3/8"
ø =
3/8"ø = 3/8"
ø =
1/2
"ø =
1/2"
7
S502TYP.
S502
6
SIM. TYP.
5
BEAM, SEE PLAN
1/4" STEEL CAP PLATE
HSS COLUMN, SEE PLAN
BEAM (BEYOND), SEE PLAN
1/2"
3/8" SHEAR PLATE
(3) 3/4" A325 BOLTS
T/STEEL
SEE PLAN
WOOD OVERBUILD NOT SHOWN FOR CLARITY
6
BEAM, SEE PLAN
CHANNEL (BEYOND), SEE PLAN
1/2"
3/8" SHEAR PLATE
(3) 3/4" A325 BOLTS
COLUMN, SEE PLAN
1/2"1/4" STEEL CAP PLATE
BEAM, SEE PLAN
(2) 3/4" A325 BOLTS
T/STEEL
SEE PLAN
WOOD OVERBUILD NOT SHOWN FOR CLARITY
8
BEAM, SEE PLANCHANNEL, SEE PLAN
3/8" SHEAR PLATE
(3) 3/4" A325 BOLTS
SLOPED HSS COLUMN, SEE PLAN
1/2"1"
3/4"
WT5X15 X 7" LONG, SLOTTED INTO COLUMN
1/2
"
ERECTION BOLT
3/16 3
3/16 3
3/163 SIDES
T/STEEL
SEE PLAN
WOOD OVERBUILD NOT SHOWN FOR CLARITY
7
3/8" SHEAR PLATE
(3) 3/4" A325 BOLTS
1/2
"
SLOPED HSS COLUMN, SEE PLAN
WT5X15 X 7" LONG, SLOTTED INTO COLUMN
ERECTION BOLT 3/16 3
3/16 3
3/16 6
3/16 6
3/8" SHEAR PLATE
(3) 3/4" A325 BOLTS
CHANNEL, SEE PLAN
BEAM, SEE PLAN CHANNEL, SEE PLAN
1/2"
T/STEEL
SEE PLAN
1 1/2"
1' - 9 5/8"
PETERSON ARCHITECTURE, P.C.
PETERSON ARCHITECTURE, P.C.
PROJECT NUMBER:
RIGHTS ARE HEREBY SPECIFICALLY RESERVED. ALL OTHER COPYRIGHT AND COMMON LAW
AND SHALL BE USED ONLY IN PURSUANT TO THE
NO OTHER USE OR DUPLICATION MAY BE MADE
THESE DRAWINGS ARE GIVEN IN CONFIDENCE
WITHOUT THE PRIOR WRITTEN CONSENT OF
AGREEMENT WITH
DRAWN BY:
CHECKED BY:
298 south 10th street
suite 500
noblesville in 46060
p 317.770.9714
f 317.770.9718
p e t e r s o n A R C H I T E C T U R E
CERTIFICATION
S501
JDT
NDB
17-112
BLU
E W
AT
ER
BLU
E W
AT
ER
, LLC
123 N
EW
JE
RS
EY
ST
RE
ET
IND
IAN
AP
OLIS
, IN
ENTRANCE CANOPY SECTIONS & DETAILS
1/4" = 1'-0"S501
3 CANOPY SECTION 1/4" = 1'-0"S501
1 CANOPY PLAN (LOW STEEL)S501
4 CANOPY STEEL - 3D 1/4" = 1'-0"S501
2 CANOPY PLAN (HIGH STEEL)
1 1/2" = 1'-0"S501
5 CONNECTION DETAIL 1 1/2" = 1'-0"S501
6 CONNECTION DETAIL 1 1/2" = 1'-0"S501
7 CONNECTION DETAIL 1 1/2" = 1'-0"S501
8 CONNECTION DETAIL
REVISIONS: DATE
5
BEAM, SEE PLAN
HSS COLUMN, SEE PLAN
1/2"
3/8" SHEAR PLATE
(3) 3/4" A325 BOLTS
T/STEEL
SEE PLAN
BEAM, BEYOND
4X4 BLOCKING BETWEEN TRUSS TOP CHORDS, SEE PLAN
SIMPSON HTT4 TENSION TIE, W/ 5/8" THRU BOLT CENTERED IN HSS COLUMN
SIMPSON MSTD STRAP
SIMPSON CMSTC16 COILED STRAP, EXTEND FULL LENGTH OF BLOCKING
ROOF SHEATHING, SEE PLAN
SIMPSON HTT4 TENSION TIE, W/ 5/8" THRU BOLT CENTERED
IN HSS COLUMN
SIMPSON MSTD SRAP
SIMPSON CMSTC16 COILED STRAP, EXTEND FULL
LENGTH OF BLOCKING
SIMPSON H3 TIE AT EACH END OF ROOF TRUSS, TYP.
2X NAILER
6
BEAM, SEE PLAN
BEAM, SEE PLAN
HSS COLUMN, SEE PLAN
4
S502
7/8" 1/2"
SHIM AS REQUIRED
3/8" SHEAR PLATE
(4) 3/4" A325 BOLTS
3/8" SHEAR PLATE
(3) 3/4" A325 BOLTS
T/STEEL
SEE PLAN
T/STEEL
SEE PLAN
CHANNEL, BEYOND
1 1/2" 3"
2"
2"
10"3"
1' - 0"7
"
5"
1 1
/2"
1 1
/2"
BEAM, SEE PLAN
HSS COLUMN, SEE PLAN
1/2" THICK STEEL PLATE
STEEL PLATE DIMENSION
(4) 3/4" A325 SLIP-CRITICAL BOLTS
3/16
3/163- SIDES
3/8" STIFFENER FOR CHANNEL SUPPORT6
"
NUMBER 2 CLEVIS
WT5X15 X 6" LONG, ATTACHED MID-DEPTH OF CHANNEL
2 1/2"
2 1
/2"
BEAM, SEE PLAN
CHANNEL, SEE PLAN
THREADED ROD, SEE PLAN FOR DIAMETER REQUIREMENT
NUMBER 2 CLEVIS
WT5X15 X 6" LONG, ATTACHED MID-DEPTH OF CHANNEL
2 1/2"
3"
2 1
/2"
BEAM, SEE PLAN
HSS COLUMN, SEE PLAN
THREADED ROD, SEE PLAN FOR DIAMETER
REQUIREMENT
3/8" SHEAR PLATE
(3) 3/4" A325 BOLTS
T/STEEL
SEE PLAN
STEEL FRAMING LEGEND
BEAM SIZE/DESIGNATIONW/ TOP OF STEEL ELEV.
TUBE STEEL COLUMN
BEAM FRAMED INTOSIDE OF TS COLUMN
BEAM FRAMED OVERTS COLUMN
BEAM TO COLUMN MOMENT CONNECTION
BEAM TO BEAMMOMENT CONNECTION
BEAM FRAMED INTO SIDE OF BEAM
BEAM CANTILEVER
W8
x10
(11
0'-0
")
6
2' - 2"
3/8" SHEAR PLATE
(3) 3/4" A325 BOLTS
CHANNEL, SEE PLAN 1/2"
HSS COLUMN, SEE PLAN
3/8" SHEAR PLATE
(2) 3/4" A325 BOLTS
5"
T/STEEL
SEE PLAN
L4X4X3/8 X 5-1/2" LONG
SHIM AS REQUIRED
BEAM, SEE PLAN
L4X4X3/8 X 5-1/2" LONG
(4) 3/4" A325 SLIP-CRITICAL BOLTS
(2 EACH FLANGE)
SEE ARCH. DWGS. FOR WOOD OVER-BUILD MEMBER SIZES AND DETAILING
PROVIDE 2X BLOCK BETWEEN ROOF JOISTS, TYP.
2X NAILER
BEAM, SEE PLAN
SIMPSON H3 TIE AT EACH END OF ROOF JOIST, TYP.
2
4' - 0"
5' -
0"
1/2" THICK GUSSET PLATE, EACH END OF
BRACE
HSS4X4X1/4 BRACE
ERECTION BOLT
3/16 8
3/16 8EACH ENDOF BRACE
3/16 5
3/16 5EACH ENDOF BRACE
1"
1"
3/8" THICK PLATE STIFFENER
SIMPSON HTT4 TENSION TIE, W/ 5/8" THRU BOLT CENTERED IN HSS COLUMN
SIMPSON MSTD STRAP SIMPSON CMSTC16 COILED STRAP, EXTEND 7'-0"
DOUBLE TOP PLATE
1" TYP.
PETERSON ARCHITECTURE, P.C.
PETERSON ARCHITECTURE, P.C.
PROJECT NUMBER:
RIGHTS ARE HEREBY SPECIFICALLY RESERVED. ALL OTHER COPYRIGHT AND COMMON LAW
AND SHALL BE USED ONLY IN PURSUANT TO THE
NO OTHER USE OR DUPLICATION MAY BE MADE
THESE DRAWINGS ARE GIVEN IN CONFIDENCE
WITHOUT THE PRIOR WRITTEN CONSENT OF
AGREEMENT WITH
DRAWN BY:
CHECKED BY:
298 south 10th street
suite 500
noblesville in 46060
p 317.770.9714
f 317.770.9718
p e t e r s o n A R C H I T E C T U R E
CERTIFICATION
S502
JDT
NDB
17-112
BLU
E W
AT
ER
BLU
E W
AT
ER
, LLC
123 N
EW
JE
RS
EY
ST
RE
ET
IND
IAN
AP
OLIS
, IN
CANOPY DETAILS
1 1/2" = 1'-0"S502
1 CONNECTION DETAIL
1 1/2" = 1'-0"S502
2 CONNECTION DETAIL 1 1/2" = 1'-0"S502
4 MOMENT CONNECTION PLATES (PLAN) 1 1/2" = 1'-0"S502
6 X-BRACING CONNECTION (PLAN)
1 1/2" = 1'-0"S502
7 X-BRACING CONNECTION
1 1/2" = 1'-0"S502
8 SECTION 1 1/2" = 1'-0"S502
3 CONNECTION DETAIL 1" = 1'-0"S502
5 KNEE BRACE
REVISIONS: DATE