Gerhard Brandt, ABB AG, Mannheim, Germany

Solutions for Performance Monitoring, Diagnosis and Optimization of Power Plants

Page 2: Gerhard Brandt, ABB AG, Mannheim, Germany Solutions for ... · PDF fileGerhard Brandt, ABB AG, Mannheim, Germany Solutions for Performance Monitoring, Diagnosis and Optimization of

© ABB GroupMarch 11, 2013 | Slide 2

Agenda

� Introduction

� Carbon-in-Ash Instrument

� Mill Runback Calculator.

� Combustion Optimization

� Soot Blowing Optimization.

� Startup Optimization

� Life-time Calculation

� Temperature State Space Control

� Life Steam Flow Calculation

� Unit Control

� Energy Optimizer

� Process Quality Monitoring

� Loop Performance Monitoring

� Energy Efficiency Consulting

Page 3: Gerhard Brandt, ABB AG, Mannheim, Germany Solutions for ... · PDF fileGerhard Brandt, ABB AG, Mannheim, Germany Solutions for Performance Monitoring, Diagnosis and Optimization of

© ABB2009-05-26 PGE2009_JSchneider_20090526.ppt | 3

Primary energy Transport Generation T&DIndustrial processes

Industrial production

80% of energyis lost

Ava

ilabl

e en

ergy

Only 20% of primary energy generates economic valueThe rest is lost to conversion processes, transportation and operational inefficiencies

Page 4: Gerhard Brandt, ABB AG, Mannheim, Germany Solutions for ... · PDF fileGerhard Brandt, ABB AG, Mannheim, Germany Solutions for Performance Monitoring, Diagnosis and Optimization of

Motivation for optimization

Benefits

� Reduce fuel consumption and emissions

� Increase flexibility

� Identify and rectify equipment problems

� Improve predictive maintenance and availability

� Optimize asset lifecycles

Measures

� Tune control loops

� Optimize the combustion process and improve boiler controls

� Optimize ramp rates, low load running and startups

� Optimize operation of multiple generating units

� Monitor and predict plant performance

� Issue early warnings for equipment diagnosis and preventive maintenance

Page 5: Gerhard Brandt, ABB AG, Mannheim, Germany Solutions for ... · PDF fileGerhard Brandt, ABB AG, Mannheim, Germany Solutions for Performance Monitoring, Diagnosis and Optimization of

© ABB3/11/2013 2VAA000312AA5100_en_CI_5.1_ Combustion Instrument - Sales Presentation | 5

� Majority of the combustible portion of the ash accounting for the energy loss is simply unburned carbon.

� Unburned carbon is a highly variable parameter which is dependent upon coal type, load, fuel and air distribution, and other boiler-specific factors, the need for on-line real-time measurement has become more critical in combustion optimization process

� ABB Carbon In Ash Instrument (CIA) provides a true real-time and representative measurements of the unburned carbon in the fly ash for utility power plants

Carbon In Ash InstrumentBasics

Page 6: Gerhard Brandt, ABB AG, Mannheim, Germany Solutions for ... · PDF fileGerhard Brandt, ABB AG, Mannheim, Germany Solutions for Performance Monitoring, Diagnosis and Optimization of

Receiver Measures Microwave Intensity (Carbon)

Dust Probes (Loading)

Microwave Oscillator 94 GHz +- 75 MHz

wave resonance

“Mirrors”

CIA Output

Carbon/Ash Loading @ %

OR

Carbon @ g/m3

� Active Component is a 94GHz Microwave System

� Slightly Parabolic “Mirrors” Create Resonant Microwave Cavity Across Furnace Back pass or Economizer Ductwork

� Total Ash Loading Determined by “Dust Probe”

Carbon In Ash InstrumentABB’s Technology Edge!

Page 7: Gerhard Brandt, ABB AG, Mannheim, Germany Solutions for ... · PDF fileGerhard Brandt, ABB AG, Mannheim, Germany Solutions for Performance Monitoring, Diagnosis and Optimization of

© ABB3/11/2013 2VAA000312AA5100_en_CI_5.1_ Combustion Instrument - Sales Presentation | 7

One microwave sender and receiver required per CIA unit

Mirrors

Dust probes

Microwave oscillator

Microwave receiver

Ash

Carbon In Ash InstrumentInstallation

Page 8: Gerhard Brandt, ABB AG, Mannheim, Germany Solutions for ... · PDF fileGerhard Brandt, ABB AG, Mannheim, Germany Solutions for Performance Monitoring, Diagnosis and Optimization of

© ABB3/11/2013 2VAA000312AA5100_en_CI_5.1_ Combustion Instrument - Sales Presentation | 8

� Increased combustion efficiency

� Increased quality of Fly Ash resulting in better sale price!

� Improved Mercury capture

� Loss of Ignition availability

� Balanced plant efficiency

� Reduced operating cost

� Reduced amount of Fly Ash & reduced Land Filling

� Reduced manual LOI procedure

Increased

ReducedABB’s Carbon in Ash Instrument

Carbon In Ash InstrumentBenefits

Page 9: Gerhard Brandt, ABB AG, Mannheim, Germany Solutions for ... · PDF fileGerhard Brandt, ABB AG, Mannheim, Germany Solutions for Performance Monitoring, Diagnosis and Optimization of

© ABB GroupMarch 11, 2013 | Slide 9

OPTIMAX® PerformanceMill Run Back Calculator

� Run-Back Calculator based on physical model of the mill

� Outputs:

� Maximal Drying capacity

� Maximal grinding capacity

� Moisture of coal / biomass

� Implemented on controller

Referenz: P. Niemczyk et al: Derivation and validation of a coal mill model for control

Page 10: Gerhard Brandt, ABB AG, Mannheim, Germany Solutions for ... · PDF fileGerhard Brandt, ABB AG, Mannheim, Germany Solutions for Performance Monitoring, Diagnosis and Optimization of

© ABB GroupMarch 11, 2013 | Slide 10

OPTIMAX® PerformanceMill Drying capacity

� MCF: Max. coal/biomass addition

� 3:30: Addition of Biomass

kg

/s

Page 11: Gerhard Brandt, ABB AG, Mannheim, Germany Solutions for ... · PDF fileGerhard Brandt, ABB AG, Mannheim, Germany Solutions for Performance Monitoring, Diagnosis and Optimization of

optimizedvalues

controlledentities

measuredvalues

Boilermodel

Optimizer

• Targets• Constraints

optimizedsetpoints

Iteration

Sum of weighted goals= minimum

Combustion Optimization Principe

Page 12: Gerhard Brandt, ABB AG, Mannheim, Germany Solutions for ... · PDF fileGerhard Brandt, ABB AG, Mannheim, Germany Solutions for Performance Monitoring, Diagnosis and Optimization of

OFADMD MV

OFA E-WBIAS MV

AUX E-WBIAS MV

AUX A-HBIAS MV

AUX B-GBIAS MV

EastAH

West AH

ID

OPACITY CV

NOxCV

FD

O2 BALANCE

CV

O2 SPBIAS MV

MILL HBIAS MV

MILL GBIAS MV

MILL BBIAS MV

MILL ABIAS MV

EAST TILTDMD MV

WEST TILTDMD MV

WB-FURNDP MV

G

LOADDMD FF

RH SPRAY CV

MAIN STEAM

RH STEAM

FEEDWATER

WESTFURNACE

EASTFURNACE

Manipulated Variable

Constraint Variable

Disturbance Feed-ForwardFF

CV

MV

LEGEND

OFADMD MV

OFA E-WBIAS MV

AUX E-WBIAS MV

AUX A-HBIAS MV

AUX B-GBIAS MV

EastAH

West AH

ID

OPACITY CV

NOxCV

FD

O2 BALANCE

CV

O2 SPBIAS MV

MILL HBIAS MV

MILL GBIAS MV

MILL BBIAS MV

MILL ABIAS MV

EAST TILTDMD MV

WEST TILTDMD MV

WB-FURNDP MV

G

LOADDMD FF

RH SPRAY CV

MAIN STEAM

RH STEAM

FEEDWATER

WESTFURNACE

EASTFURNACE

Manipulated Variable

Constraint Variable

Disturbance Feed-ForwardFF

CV

MV

LEGEND� NOx – maximum constraint,

main objective

� Opacity – maximum constraint, noisy value

� O2 imbalance – delta O2 between furnaces, controlled with furnace biases on Aux Air and OFAD

� Actuator constraints – must keep base DCS loops in operating range, usually below a max output

� Spray valves

� Dampers

Combustion Optimizer Typical Scope

Page 13: Gerhard Brandt, ABB AG, Mannheim, Germany Solutions for ... · PDF fileGerhard Brandt, ABB AG, Mannheim, Germany Solutions for Performance Monitoring, Diagnosis and Optimization of

NOx (ppm)

� Max limit lowered sequentially by 10 ppm from 225 to 195

Combustion Optimizer Reference: reducing NOx

Page 14: Gerhard Brandt, ABB AG, Mannheim, Germany Solutions for ... · PDF fileGerhard Brandt, ABB AG, Mannheim, Germany Solutions for Performance Monitoring, Diagnosis and Optimization of

© ABB GroupMarch 11, 2013 | Slide 14

Lifetime MonitoringMotivation

Boilers

� Increasing peak operation results in additional load cycles on individual components

� New component materials allow higher steam parameters

� Optimum plant or boiler operation is achieved when the:

� Operation is safe, and when there is

� Good Agreement between design and the current operating lifetime consumption

Turbines

� Requirement for operational safety and high availability

� Obligation to prevent highly stressed components from failing,

� due to:

� Permanent loads such as high pressures and temperatures

� Centrifugal forces in a high temperature range

� Low-frequency alternating loads

Page 15: Gerhard Brandt, ABB AG, Mannheim, Germany Solutions for ... · PDF fileGerhard Brandt, ABB AG, Mannheim, Germany Solutions for Performance Monitoring, Diagnosis and Optimization of

© ABB GroupMarch 11, 2013 | Slide 15

Features� Online calculation of lifetime consumption of

critical components� BoilerLife certified by TÜV� Calculations according to international

standards� Online reporting on lifetime status of critical

components

Benefits� Improving maintenance planning � Ensure that components will not fail or need

replacement too early� Certified reporting to safety authorities

Lifetime MonitoringBoiler and Turbine

Page 16: Gerhard Brandt, ABB AG, Mannheim, Germany Solutions for ... · PDF fileGerhard Brandt, ABB AG, Mannheim, Germany Solutions for Performance Monitoring, Diagnosis and Optimization of

© ABB GroupMarch 11, 2013 | Slide 16

Activation signals for individual soot blower groups are: � Temperature limits� Soot blower steam consumption � Water consumption of water injectors � Boiler efficiency� Injection rates of intermediate superheaters� Pressure losses� Blower performance

Soot Blowing Optimization Model based calculation of heat exchangers

Page 17: Gerhard Brandt, ABB AG, Mannheim, Germany Solutions for ... · PDF fileGerhard Brandt, ABB AG, Mannheim, Germany Solutions for Performance Monitoring, Diagnosis and Optimization of

© ABB GroupMarch 11, 2013 | Slide 17

Soot Blowing OptimizationCalculation results with a detailed boiler model

Calculated conditions of

heat exchange areas

Start of soot

blowing sequence

Features� Provides operator guidance as to

when to initiate a soot blowing sequence

� Calculates cleanliness factors per section

� Measures heat transfer efficiency� Applies to furnace, walls and

convective sections

Benefits� Easy-to-spot effects of minor

changes in soot blowing sequences� Significant heat rate savings� Increase in long term plant

performance� Online computation of surface

cleanliness� Typical payback time < 2 years

9000 kJ/kW h Heat for Sootblowing [MJ/d] Total Heat Loss [MJ/d] 383.5

1350

203.6

5.55555556

0

50

100

150

200

250

300

350

400

450

1 2 4 8 16

Heat Loss [MJ/d]

Heat for Sootblow ing [MJ/d]

Total Heat Loss [MJ/d]

Page 18: Gerhard Brandt, ABB AG, Mannheim, Germany Solutions for ... · PDF fileGerhard Brandt, ABB AG, Mannheim, Germany Solutions for Performance Monitoring, Diagnosis and Optimization of

© ABB GroupMarch 11, 2013 | Slide 18© ABB3/11/2013 Enter filename via "View - Header and Footer...". Apply to all. | 18

BoilerMaxBoiler start-up Optimization

Benefits:

� Shorter start-up and shut-down time reduces fuel consumption

� Faster load response to load dispatcher, advantages in energy trading

� Explicit consideration of thermal stresses in thick-walled components, control of temperature variances during start-up

� Earlier warm-up and speed-up of the steam turbine and therefore earlier grid synchronization possible

Page 19: Gerhard Brandt, ABB AG, Mannheim, Germany Solutions for ... · PDF fileGerhard Brandt, ABB AG, Mannheim, Germany Solutions for Performance Monitoring, Diagnosis and Optimization of

© ABB GroupMarch 11, 2013 | Slide 19© ABB11.03.2013 Enter filename via "View - Header and Footer...". Apply to all. | 19

BoilerMaxFunctional principle

manipulated

values

Boiler

model

Optimizer

optimized

setpoints

and inputs

Iterations

Cost function

= Minimum !

process values

Nonlinear Model Predictive Control (NMPC) with cyclic tracking of the real process

Power plant

boiler

optimized

values

Optimization aims

Page 20: Gerhard Brandt, ABB AG, Mannheim, Germany Solutions for ... · PDF fileGerhard Brandt, ABB AG, Mannheim, Germany Solutions for Performance Monitoring, Diagnosis and Optimization of

© ABB GroupMarch 11, 2013 | Slide 20© ABB3/11/2013 Enter filename via "View - Header and Footer...". Apply to all. | 20

Tm: mid temperature

Ti: inner temperature

BoilerMaxDetermination of thermal stresses

Principle:

� Temperature difference ∆T is indicator for thermal stresses

� Measurement of ∆T between inner surface and the mean diameter of the annular cross section of thick-walled components

� Alternative 1: determination on non-heated surface

� Alternative 2: indirect determination from steam temperature gradients

∆T ≈ Tm - Ti

∆∆∆∆T live steam header in °C

∆∆∆∆T limit

Page 21: Gerhard Brandt, ABB AG, Mannheim, Germany Solutions for ... · PDF fileGerhard Brandt, ABB AG, Mannheim, Germany Solutions for Performance Monitoring, Diagnosis and Optimization of

© ABB GroupMarch 11, 2013 | Slide 21© ABB11.03.2013 Enter filename via "View - Header and Footer...". Apply to all. | 21

BoilerMaxEnhanced start-up phase

� Traditional start-up to comply with design limits

� BoilerMax start-up allows exploitation of design limits for more efficient process control:

� Based on process model

� NMPC technology

� Predictive coordination of multiple variables

� Online optimization in real-time

Up to 15% savings due to

fast and low-stress boiler

start-up

Fuel flow

HP-Bypass position

LS temperature

dT thick-walled component

Traditional – BoilerMax

Page 22: Gerhard Brandt, ABB AG, Mannheim, Germany Solutions for ... · PDF fileGerhard Brandt, ABB AG, Mannheim, Germany Solutions for Performance Monitoring, Diagnosis and Optimization of

© ABB GroupMarch 11, 2013 | Slide 22

m E•

R2R1 R3 R4

M

PI

PI-State Space Controller

TE T1 T2 T3 TA

mD•

Attemperator Q Burner

K1 K2 K3 K4

SP TA

Error

–+

T1^ T2

^ T3^ TA

^

–+

Observer

F

State Space ControllerImproved Temperature Control

Page 23: Gerhard Brandt, ABB AG, Mannheim, Germany Solutions for ... · PDF fileGerhard Brandt, ABB AG, Mannheim, Germany Solutions for Performance Monitoring, Diagnosis and Optimization of

PI-PI-cascadeState Controller

with Observer (SCOT)

Physical Temperature Limit

DCS max Temperature

Temperature SP

Tout

Time

Outlet Temperature ∆T Set Point

� Increasing the live steam and rehated steam operation temperature results in an immediate increment of unit efficiency

� With a higher set point, however, the margin between the operation point and max. admissible temperature is reduced

� This is no problem thanks to the improved performance that the state controller delivers

State Space ControllerImproved Temperature Control

Page 24: Gerhard Brandt, ABB AG, Mannheim, Germany Solutions for ... · PDF fileGerhard Brandt, ABB AG, Mannheim, Germany Solutions for Performance Monitoring, Diagnosis and Optimization of

© ABB GroupMarch 11, 2013 | Slide 24

PI-PI State Space Controller

(SSC)

Potential live steam

temperature increase

Physical Limit

DCS Limit

PI-PI SP

SP SSC

OPTIMAX® State Space ControllerImproved Temperature Control

Page 25: Gerhard Brandt, ABB AG, Mannheim, Germany Solutions for ... · PDF fileGerhard Brandt, ABB AG, Mannheim, Germany Solutions for Performance Monitoring, Diagnosis and Optimization of

© ABB GroupMarch 11, 2013 | Slide 25

Life Steam Flow CalculationReduction of Throttling Losses

HP-bypass

Turbine inlet control valves

pcold RH

pT

Estimated value•

mLS

m•

LS

LS LS ∆p

PEI

G

RH

live steam flowcalculation

(ABB patent)

TLS

pHP

Page 26: Gerhard Brandt, ABB AG, Mannheim, Germany Solutions for ... · PDF fileGerhard Brandt, ABB AG, Mannheim, Germany Solutions for Performance Monitoring, Diagnosis and Optimization of

© ABB GroupMarch 11, 2013 | Slide 26

MODAN:Modified sliding pressureby turbine valve throttling

CONDSTOP:Fast shutdown of the LP FW heater line on steam and condensate side

MODAKOND:Modified sliding pressure by turbine valve throttling and LP heater line shutdown

Unit ControlFlexible and Reliable Operation

pFD k·∆f–+

– +

+

+–

Dyn. PressureMddel

Unit SPFrequency demand

PressureControl

Fuel Controller

FeedforwardBoiler

Dynamic LoadModel

Dynamic

Feedforward

ABB-CONDSTOP

0

6

12

15

18

40 70 100

stationäre Turbinenandrosselung in %

Last in %

MODAN

MODAKOND(ABB-CONDSTOP)

FeedforwardTurbine

Load Dispath

PEI

P–

GZÜ

Dynamic, Controlled Runbacks

Page 27: Gerhard Brandt, ABB AG, Mannheim, Germany Solutions for ... · PDF fileGerhard Brandt, ABB AG, Mannheim, Germany Solutions for Performance Monitoring, Diagnosis and Optimization of

© ABB11.03.2013 | 27

Energy Optimizer

� Flexible exploitation of different production units

� Gas turbines

� Boilers

� Steam turbines

� Different fuels

� Varying operational policies.:

� Prio steam production

� Prio el. production

� Start/Stop of boilers and turbines

� Energy Optimizer: Online-Optimization considering process constraints and market needs

Page 28: Gerhard Brandt, ABB AG, Mannheim, Germany Solutions for ... · PDF fileGerhard Brandt, ABB AG, Mannheim, Germany Solutions for Performance Monitoring, Diagnosis and Optimization of

© ABB11.03.2013 | 28

Reference 1: Internal Optimization JänschwaldePooling of six 500 MW units

Advantage of Multi-unit optimization� Exploit communication network between management system and unit control system� Real-time optimization of set points and secondary frequency control� Fast and optimal reaction to fulfill production task, incl. gradients and timing of load ramps� Goals:

� minimize fuel consumption and CO2-emmissions� increase flexibility

Page 29: Gerhard Brandt, ABB AG, Mannheim, Germany Solutions for ... · PDF fileGerhard Brandt, ABB AG, Mannheim, Germany Solutions for Performance Monitoring, Diagnosis and Optimization of

Reference 2: Pooling of up to 500 biogas plants

Process Database Redundant Controller IEC 60870-5-104 ScannerOperation & Management

Operations Client Engineering ClientImport / Export for

operational management

Service Client

Up to 500 production units,typically 500 kW per unit

4 GridOperators

Page 30: Gerhard Brandt, ABB AG, Mannheim, Germany Solutions for ... · PDF fileGerhard Brandt, ABB AG, Mannheim, Germany Solutions for Performance Monitoring, Diagnosis and Optimization of

� Process values alone usually give no information about the efficiency or the

process quality of a plant

12,2

3,7

4,0

0,2233

123,45312.3

12.0

12.6 23.4

12.8

23.4

12.4 11.823.4

12.4

2,412,5

OPTIMAX® PlantPerformanceStarting point: Monitoring of Process Values in DCS

Page 31: Gerhard Brandt, ABB AG, Mannheim, Germany Solutions for ... · PDF fileGerhard Brandt, ABB AG, Mannheim, Germany Solutions for Performance Monitoring, Diagnosis and Optimization of

� Performance indicators are determined by using multiple process values

12,2

3,7

4,0

0,2233

123,45312.3

12.0

12.6 23.4

12.8

23.4

12.4 11.823.4

12.4

2,412,5

96%

72%

90% 39%87%

72%68%

OPTIMAX® PlantPerformanceDetermination of Performance Indicators

Page 32: Gerhard Brandt, ABB AG, Mannheim, Germany Solutions for ... · PDF fileGerhard Brandt, ABB AG, Mannheim, Germany Solutions for Performance Monitoring, Diagnosis and Optimization of

ηact ηexp

Comp. 1

Total Plant

ηactηexp

ηact ηexp

Plant Area 1

ηact ηexp

Plant Area 2

ηact ηexp

Comp. 2

OPTIMAX® PlantPerformanceIdentifying the origin of a performance deviation

Page 33: Gerhard Brandt, ABB AG, Mannheim, Germany Solutions for ... · PDF fileGerhard Brandt, ABB AG, Mannheim, Germany Solutions for Performance Monitoring, Diagnosis and Optimization of

© ABB3/11/2013 | 33

Loop Auditing

� Transparent commissioning of control through loop optimizer.

� Model based tuning of each individual loop with a well documented report for each loop

� Reports are available at any time during commissioning giving a fast and accurate account of the loop commissioning status.

� Fully integrated into the System 800xA

Page 34: Gerhard Brandt, ABB AG, Mannheim, Germany Solutions for ... · PDF fileGerhard Brandt, ABB AG, Mannheim, Germany Solutions for Performance Monitoring, Diagnosis and Optimization of

© ABB3/11/2013 | 34

Loop Auditing

� Loop auditing given feedback on current control loop performance to detect worsening control loop behavior.

� Indicating on possible causes for the worsening of the control loop performance.

Loop Reports

Causes

Optimize Loops

Page 35: Gerhard Brandt, ABB AG, Mannheim, Germany Solutions for ... · PDF fileGerhard Brandt, ABB AG, Mannheim, Germany Solutions for Performance Monitoring, Diagnosis and Optimization of

Power and Water Plant OperationsABB Industrial Energy Efficiency (IEE) Assessment

Page 36: Gerhard Brandt, ABB AG, Mannheim, Germany Solutions for ... · PDF fileGerhard Brandt, ABB AG, Mannheim, Germany Solutions for Performance Monitoring, Diagnosis and Optimization of