2
Green ImagingTechnologies’ GIT Systems software is a powerful SCAL solution. This unique software suite uses Nuclear Magnetic Resonance (NMR) to obtain both standard and specialized reservoir measurements. Its advanced capabilities are underpinned by a robust,user-friendly platform that streamlines every aspect of NMR data acquisition, processing and reporting. With an emphasis on clarity, simplicity and usability,it maximizes a core’s data potential. BASE SOFTWARE GIT Systems software is run on an intuitive platform that greatly simplifies the acquisition of NMR measurements in the lab. It provides direct hardware control and diagnostics for a variety of NMR instruments and field strengths while maintaining system accuracy through automated calibrations. Both T 1 and T 2 data can be acquired and automatically processed to give FFI, BVI, CBW, effective porosity, andT 1 and T 2 cut-offs. Features include advanced help, imperial or SI unit display and entry, file import (ASCII and RIDAT formats), and database backup and restore. GIT-CAP™ The patented GIT-CAP capillary pressure measurement is directly determined using the known centrifugal force and the NMR-measured water saturation. GIT-CAP is available for both air/brine and oil/brine systems. The GIT-CAP module for oil/brine is unique in that it provides both the positive and negative portions of the curves, giving primary drainage, secondary drainage, and imbibition. GIT-CAP has been proven to be accurate within 2% of conventional measurement techniques and needs only one or two centrifuge equilibrium speeds to measure the complete capillary pressure curve – more than 5 times faster than conventional centrifuge techniques. FEATURES Data generated by the GIT-CAP technique can be used extensively to model such reservoir parameters as NMR permeability, wettability, and relative permeability. One of the most exciting features is QUICK-CAP™, which determines the complete capillary pressure curve using a single equilibrium centrifuge speed. All features are easily accessed and calculated using the intuitive user interface. GIT Systems CLARITY • Easy-to- understand acquisition, processing and reporting • Intuitive Windows-based user interface SIMPLICITY • Automatically calculate FFI, BVI, CBW, effective porosity, T 1 and T 2 cut-offs • Makes NMR scanning by non- experts a reality USABILITY • Integrates T 1 or T 2 measurements with capillary pressure workflow • Dramatically improves measurement speed and accuracy www.greenimaging.com

GIT Systems

Embed Size (px)

DESCRIPTION

Product sheet for GIT Systems R2.0 software

Citation preview

Page 1: GIT Systems

Green ImagingTechnologies’ GIT Systems software is a powerful SCAL solution.This unique software suite uses Nuclear Magnetic Resonance (NMR) to obtain bothstandard and specialized reservoir measurements. Its advanced capabilities areunderpinned by a robust, user-friendly platform that streamlines every aspect of NMRdata acquisition, processing and reporting. With an emphasis on clarity, simplicity andusability, it maximizes a core’s data potential.

BASE SOFTWAREGIT Systems software is run on an intuitiveplatform that greatly simplifies the acquisition ofNMR measurements in the lab. It provides directhardware control and diagnostics for a variety ofNMR instruments and field strengths whilemaintaining system accuracy through automatedcalibrations. BothT1 andT2 data can be acquiredand automatically processed to give FFI, BVI, CBW,effective porosity, andT1 andT2 cut-offs. Featuresinclude advanced help, imperial or SI unit displayand entry, file import (ASCII and RIDAT formats),and database backup and restore.

GIT-CAP™The patented GIT-CAP capillary pressuremeasurement is directly determined using theknown centrifugal force and the NMR-measuredwater saturation. GIT-CAP is available for bothair/brine and oil/brine systems. The GIT-CAPmodule for oil/brine is unique in that it providesboth the positive and negative portions of thecurves, giving primary drainage, secondary drainage,and imbibition. GIT-CAP has been proven to beaccurate within 2% of conventional measurementtechniques and needs only one or two centrifugeequilibrium speeds to measure the completecapillary pressure curve – more than 5 times fasterthan conventional centrifuge techniques.

FEATURESData generated by the GIT-CAP technique can be used extensively to model such reservoirparameters as NMR permeability, wettability, and relative permeability. One of the most excitingfeatures is QUICK-CAP™, which determines the complete capillary pressure curve using asingle equilibrium centrifuge speed. All features are easily accessed and calculated using theintuitive user interface.

GIT Systems

CLARITY• Easy-to-understandacquisition,processingand reporting

• IntuitiveWindows-baseduser interface

SIMPLICITY• Automaticallycalculate FFI,BVI, CBW,effective porosity,T1 and T2 cut-offs

• Makes NMRscanning by non-experts a reality

USABILITY• Integrates T1 or T2measurementswith capillarypressure workflow

• Dramaticallyimprovesmeasurementspeed and accuracy

w w w . g r e e n i m a g i n g . c o m

Page 2: GIT Systems

46 Dineen DriveFredericton, NBCanada E3B 9W4Tel: +1 506 458 9992Fax: +1 506 458 [email protected]

LITHOLOGIESGIT Systems has beenproven effective inmultiple lithologies,and excels in lowpermeability situations.

T1 andT2Routine rock core measurements, includingT1 andT2 distributions, can easily bemeasured using GIT Systems. The FFI, BVI,CBW, effective porosity, T1andT2 cut-offsare automatically computed. Log calibrationand interpretation are improved by usingthese more accurate values.

RELATIVE PERMEABILITYThe correct modeling of reservoir fluidflow is crucial to achieving productionsuccess; yet obtaining reliable relativepermeability data can be difficult andexpensive. Further, this data is often usedto model capillary pressure curves. GITSytems’ relative permeability measurementreverses this procedure and providesdetailed relative permeability data quicklyfrom NMR capillary pressure curves.

WETTABILITYWettability affects many important reservoir characteristics, includingrelative permeability, electrical properties, NMR properties andsaturation profiles, which can all have a critical impact on productionplanning. GIT Systems allows wettability to be modeled from thecapillary pressure results, using the AMOTT or USBM indices.

POROSITY PROFILEGIT Systems uses the NMR instrument to“see” fluids inside the core plug. By directlymeasuring these fluids, the software cancalculate a porosity profile of the plug. Thisis in contrast to a traditional bulk porositymeasurement, which may mask small-scaleheterogeneity in the rock.