32
www.lgeaircon.com 2008 LG Air Conditioner Accessories 2008 LG Air Conditioner Accessories Air Conditioner 20 Yeouido-dong, Yeongdeungpo-gu, Yeouido P.O.Box 335 Seoul, 150-721, Korea. Phone : +82-2-3777-7958 Fax : +82-2-3777-5139 www.lgeaircon.com Distributed by GL-AC081

GL-AC081forfuture.cz/SOUBORY/KATALOGY/KATALOGY_LG/LG... · PQRCUSA0 PCRCUSZ0 PZRCUSB0 PDRCUSZ0 PQRCUDS0 (White) PQRCUDSOB (Blue) PQRCUDSOS (Silver) Wired Remote Controller Simple

  • Upload
    others

  • View
    0

  • Download
    0

Embed Size (px)

Citation preview

Page 1: GL-AC081forfuture.cz/SOUBORY/KATALOGY/KATALOGY_LG/LG... · PQRCUSA0 PCRCUSZ0 PZRCUSB0 PDRCUSZ0 PQRCUDS0 (White) PQRCUDSOB (Blue) PQRCUDSOS (Silver) Wired Remote Controller Simple

ww

w.l

ge

air

co

n.c

om

2008 LG Air Conditioner

Accessories

2008 LG Air Conditioner

Accessories

Air Conditioner

20 Yeouido-dong, Yeongdeungpo-gu,

Yeouido P.O.Box 335 Seoul, 150-721, Korea.

Phone : +82-2-3777-7958 Fax : +82-2-3777-5139

www.lgeaircon.com

Distributed byG

L-AC081

Page 2: GL-AC081forfuture.cz/SOUBORY/KATALOGY/KATALOGY_LG/LG... · PQRCUSA0 PCRCUSZ0 PZRCUSB0 PDRCUSZ0 PQRCUDS0 (White) PQRCUDSOB (Blue) PQRCUDSOS (Silver) Wired Remote Controller Simple

C o n t e n t s

Brief History

V-net 04Remote Controller 06

Central Controller 12

Electronic Accessory 28

Mechanical Accessory 40

Piping Accessory 52

Establishment1947 Establishment of the LG Group1958 Establishment of LG Electronics Inc.1962 Establishment of Digital Appliance Company

Growth1968 Manufactured Korea’s first air conditioners1985 Introduced Korea’s first Inverter air conditioners1986 Exported Korea’s first window type air conditioners

Expansion1995 Establishment of LGETA in china1997 Establishment of LGEIL in India1999 Establishment of LGEAT in Turkey1999 Establishment of LGEMH in Vietnam2001 Establishment of LGEAZ in Brazil2002 Establishment of LGETH in Thailand2002 Establishment of LGEIN in Indonesia2004 Turnover of US$1.4 Billion dollars

Global Air Conditioning Academies

LG Air Conditioner_Accessories

Changwon in Korea

Spain Italy Dubai China Saudi Arabia

Pyeongtaek in Korea Thailand

Mexico Panama Indonesia Iran Turkey Vietnam

England France Australia Moscow Singapore

Page 3: GL-AC081forfuture.cz/SOUBORY/KATALOGY/KATALOGY_LG/LG... · PQRCUSA0 PCRCUSZ0 PZRCUSB0 PDRCUSZ0 PQRCUDS0 (White) PQRCUDSOB (Blue) PQRCUDSOS (Silver) Wired Remote Controller Simple

Line up

RemoteController

CentralController

ElectronicAccessory

Wireless RemoteController

Simple

PQWRH(C)DF0PQWRH(C)SF0PPWRH(C)SF0

PQRCUCA0 (Simple)PQRCFCS0 (Simple for Hotel)PQRNC0 (Simple for operation with Radiator)

PQCSB101S0PQCSB101S0+PQCSC101S0PQCSB101S0+PQCSC101S0

(FunctionController) (Scheduler)

PQCSW320AE

PQCSW502A2

PQCSS513A0

PQCPA11A0E (With IO),PQCPB11A0E (Without IO)PQCSS520A0E (AC Manager)

PQNFB16A1 (LONWORKS®)PQNFB17B0 (BACnet)

PI 485, CNU, DO Kit, Dry Contact, Cool/Heat Selector, Zone Controller, Electronic Thermostat, CTI, Low Ambient Kit,Remote Temperature Sensor, PDI, Telecom Shelter Controller

PQRCUSA0

PCRCUSZ0

PZRCUSB0

PDRCUSZ0

PQRCUDS0 (White)PQRCUDSOB (Blue)PQRCUDSOS (Silver)

Wired RemoteController

Simple CentralController

AC Smart

Deluxe CentralController

PC Based CentralController

ACP & AC Manager

BMS

Standard

Deluxe

V-N

ET

04

05

V-net, LG Network Solution provide comfortable environment and energy savingby optimum control of Air -conditioning system.

Page 4: GL-AC081forfuture.cz/SOUBORY/KATALOGY/KATALOGY_LG/LG... · PQRCUSA0 PCRCUSZ0 PZRCUSB0 PDRCUSZ0 PQRCUDS0 (White) PQRCUDSOB (Blue) PQRCUDSOS (Silver) Wired Remote Controller Simple

Remote Controller Line up

Remote controllerOur air conditioning system can be controlled by various types of remote controllers providing general control to unique function.

Re

mo

te C

on

trolle

r

06

07

SSttaannddaarrdd WWiirreeddRReemmoottee CCoonnttrroolllleerr

DDeelluuxxee WWiirreedd RReemmootteeCCoonnttrroolllleerr

SSiimmppllee WWiirreedd RReemmootteeCCoonnttrroolllleerr

WWiirreelleessss RReemmootteeCCoonnttrroolllleerr

08

09

10

11

Function PQRCFCS0 PQRCUCA0 PQRCUSA0 PQRCUDS0(B,S) PQWRHDF0

On / Off

Fan speed

Temperature setting

Mode change

Auto swing

Vane control

E.S.P function

Reservation

Timer Function

Electric failure compensation

Child lock

•••

•••••

•••••••••••

•••••••••

••••

Page 5: GL-AC081forfuture.cz/SOUBORY/KATALOGY/KATALOGY_LG/LG... · PQRCUSA0 PCRCUSZ0 PZRCUSB0 PDRCUSZ0 PQRCUDS0 (White) PQRCUDSOB (Blue) PQRCUDSOS (Silver) Wired Remote Controller Simple

FEATURES

Operating modeOn / Off LEDRoom temp.Fan / Plasma / Swirl / HeaterVane control / Auto swing / Fan autoE.S.P functionReservationTimer functionChild lockElectric failure compensationWireless remocon receiverMain/Sub setting of indoor units (For override function)ΔT setting (For Auto Changeover)2 Controllers to 1 indoor unitsGroup and central control at the same time★ Applicable for only MULTI V II series (MULTI V PLUS II, MULTI V SYNC II, MULTI V SPACE II , MULTI V MINI & ‘08 new indoor units)※ Refer to each model PDB for applicable models.

On_Off / Fan speed / Mode / Temp.

Weekly / Simple

Max 2 hours

★MULTI V SYNC II

★★

PQRCUSA0

Standard Wired Remote Controller08 09R E M OT E CO N T RO L L E R

For Air conditioner

PQRCUSA0 / PCRCUSZ0PDRCUSZ0 / PZRCUSB0

The standard remote controller can be used by various means.It can control an indoor units or group of indoor units.

FEATURES

For

PQRCUSA0

Operating modeOn / Off LEDRoom temp.Fan / Plasma / HeaterSwirl / Vane control / Auto swingFan autoE.S.P functionReservationTimer functionChild lockElectric failure compensationWireless remocon receiver※ Refer to each model PDB for applicable models.

On_Off / Fan speed / Mode / Temp.

-

Weekly / Simple

Max 2 hours

On_Off / Fan speed / Mode / Temp.

--

Weekly / Simple

Max 2 hours-

PDRCUSZ0PCRCUSZ0

PCRCUSZ0 PDRCUSZ0

PZRCUSB0

On / Off LEDVentilation mode settingRapid ventilationPower saving ventilationReservationElectric failure compensationChild lockOptional function

Weekly / SimpleMax 2 hours

Plasma / Heater / Humidifier / Operating air volume

PZRCUSB0

Deluxe Wired Remote Controller R E M OT E CO N T RO L L E R

PQRCUDS0 / PQRCUDS0B / PQRCUDS0S

With the future-oriented design more suitable for the high-end interior, the deluxe wired remote controller makes a perfect match with interior.

Re

mo

te C

on

trolle

r

08

09

PQRCUDS0 (White) PQRCUDS0B (Blue) PQRCUDS0S (Silver)

FEATURES

Operating modeTouch screen / LCD back_lightRoom tempFan / Plasma / Swirl / HeaterVane control / Auto swing E.S.P functionReservationTimer functionChild lock

On_Off / Fan speed / Mode / Temp.

Weekly / Simple

PQRCUSDS0, PQRCUSDS0B, PQRCUSDS0S

※ Refer to each model PDB for applicable models.

Page 6: GL-AC081forfuture.cz/SOUBORY/KATALOGY/KATALOGY_LG/LG... · PQRCUSA0 PCRCUSZ0 PZRCUSB0 PDRCUSZ0 PQRCUDS0 (White) PQRCUDSOB (Blue) PQRCUDSOS (Silver) Wired Remote Controller Simple

Simple Wired Remote Controller10 11R E M OT E CO N T RO L L E R

PQRCUCA0 / PQRCFCS0 / PQRNC0

The simple wired remote controller with handy design is suitable for hotelor office applications because user can control air conditioner easily.

Wireless Remote ControllerR E M OT E CO N T RO L L E R

PQWRH(C)DF0/PQWRH(C)SF0PPWRH(C)SF0

PQWRH(C)DF0 PQWRH(C)SF0 PPWRH(C)SF0

The wireless remote controller allows the operation of air conditioner from any corner of the room.

Re

mo

te C

on

trolle

r

1 0

1 1

FEATURES

FEATURES

COMBINATION

PQRCUCA0 (Simple)

PQRCFCS0 (Simple for Hotel)

PQRNC0 (Simple for operation with radiator)

Operation modeMode changeRoom tempPlasmaAuto swingChild lockParts included

On_Off / Fan speed / Mode / Temp.Cooling / Heating / Fan

PQRCUCA0On_Off / Fan speed / Temp.

Impossible

PQRCFCS0On_Off / Fan speed / Mode / Temp.

Auto change over-

-

PCB Case Cable

PQRNC0

Operating modeRoom temperature checkingChaos swing / Jet coolOn_Off timerSleep mode autoMain / Sub setting of indoor units(For override function)ΔT setting (for Auto Changeover)

PPWRH(C)SF0On_Off / Fan speed / Mode / Temp

-

-

PQWRH(C)DF0On_Off / Fan speed / Mode / Temp

MULTI V SYNC II

PQWRH(C)SF0On_Off / Fan speed / Mode / Temp

-

-

MODEL NAME & APPLICABLE MODELS

PQWRHDF0

PQWRCDF0

PQWRHSF0

PQWRCSF0

PPWRHSF0

PPWRCSF0

PACType

H/P

C/O

H/P

C/O

H/P

C/O

CST, SRAC, CVT, Duct,Floor Standing※ Refer to each model PDB for applicable models.

★ Applicable for only MULTI V II series (MULTI V PLUS II, MULTI V SYNC II, MULTI V SPACE II , MULTI V MINI & ‘08 new indoor units)※ Refer to each model PDB for applicable models.

Page 7: GL-AC081forfuture.cz/SOUBORY/KATALOGY/KATALOGY_LG/LG... · PQRCUSA0 PCRCUSZ0 PZRCUSB0 PDRCUSZ0 PQRCUDS0 (White) PQRCUDSOB (Blue) PQRCUDSOS (Silver) Wired Remote Controller Simple

Central ControllerThe central controller offers more comfortable and convenient life byautomatic control such as cooling, heating, ventilating, monitoring,scheduling, peak control, etc.

Ce

ntra

l Co

ntro

ller

1 2

13

SSiimmppllee CCeennttrraall CCoonnttrroolllleerr

FFuunnccttiioonn CCoonnttrroolllleerr && SScchheedduulleerr

AACC SSmmaarrtt

DDeelluuxxee CCeennttrraall CCoonnttrroolllleerr

PPCC BBaasseedd CCeennttrraall CCoonnttrroolllleerr

AACCPP && AACC MMaannaaggeerr

BBNNUU((LLOONNWWOORRKKSS®®))

BBNNUU((BBAACCnneett))

PPII 448855

CCNNUU

14

15

16

18

20

22

24

25

26

27

Central Controller Line up

Function PQCSB101S0

On / Off

Max. no. of indoor units

Mode change

Control of each room

Total lock

Error check

Fan speed / Temperature control

Schedule

Ventilation control

PDI Monitoring

Web access

Set temp. range restriction

Auto Changeover

Temperature limit control

Histoy

Interlocking function

Multi language

•16

•••

LED

PQCSB101S0+PQCSC101S0

•16

•••

LCD display

PQCSB101S0+PQCSD130A0

•16

•••

LCD display

•Weeky

PQCSW320A0E

•64(128)

•••

Self-diagnosis

•Weekly / Yearly

•••••

PQCSW502A2

•256

•••

Self-diagnosis

•Weekly / Yearly

••

PQCSS513A0

•2,048

•••

Self-diagnosis

•Weekly / Yearly

••

PQCPB11A0E+PQCSS520A0E

•4,096

•••

Self-diagnosis

•Weekly / Yearly

•••••••••

Page 8: GL-AC081forfuture.cz/SOUBORY/KATALOGY/KATALOGY_LG/LG... · PQRCUSA0 PCRCUSZ0 PZRCUSB0 PDRCUSZ0 PQRCUDS0 (White) PQRCUDSOB (Blue) PQRCUDSOS (Silver) Wired Remote Controller Simple

FEATURES

Simple Central Controller14 15C E N T R A L CO N T RO L L E R

PQCSB101S0

Simple and easy central control for 16 indoor units is made bythis controller, a distinctive product.

NAME AND DESCRIPTION OF THE SYSTEM

COMBINATION

Function Controller & SchedulerC E N T R A L CO N T RO L L E R

PQCSB101S0+PQCSC101S0PQCSB101S0+PQCSD130A0

Apart from on/off control, operation mode, fan speed,schedule, additional functions can be displayed and easilycontrolled.

Ce

ntra

l Co

ntro

ller

1 4

15

FEATURES

Max. no. of indoor unitsIndividual controlLock functionMode changeMalfunction indicatorDimension(mm)Power(V)

16 indoor unitsOn_Off control

Total / IndividualCooling / Heating

LED lamp120x120x20

DC 10V

PQCSB101S0

On/Off Display LED (TOTAL 16EA)On pressing individual on/off button,

display the present operation state.- Cool / Dry / Fan : Green.

- Heat : Orange- Error mode : Red

- Stop : Off

Power indication LED Indicate the state of DC Power supply in central control unit.

- On : Red(Heating), Green(Cooling)- Off : no signal

- Error mode : blinking with red color

※ No need of PI 485, when use MULTI V II series outdoor with '08 new indoor units.

※ No need of PI 485, when use MULTI V II series outdoor with '08 new indoor units.

Individual buttonControl On/OFF of a single unit

‘ TOTAL Off ’ buttonStop all linked units sequentially.

‘ TOTAL On ’ buttonOperate all linked units sequentially.

Max. no. of indoor units

Individual control

Lock function

Mode change

Malfunction indicator

Schedule

Dimension(mm)

Power(V)

* 1 function controller or scheduler can be combined with 8 simple central controllers.

SCC + FunctionController

(FunctionController)

(Scheduler)SCC + Scheduler

PQCSB101S0+PQCSD130A016 indoor units

On_Off / Fan speed / Mode / Temp.Total / Individual

Cooling / Heating / FanError display on LCD

Weekly(120x120x20)+(120x133x20)

DC 10V

PQCSB101S0+PQCSC101S016 indoor units

On_Off / Fan speed / Mode / Temp.Total / Individual

Cooling / Heating / FanError display on LCD

-(120x120x20)+(70x120x14)

DC 10V

PQCSB101S0

Vcc, GND

RS485

AC220V

MULTI, Single A

MULTI V PLUS IIMULTI V SYNC IIMULTI V SPACE IIMULTI V MINI

MULTI V PLUSMULTI V SYNCMULTI V SPACE

MULTI V PLUS IIMULTI V SYNC IIMULTI V SPACE IIMULTI V MINI

MULTI V PLUSMULTI V SYNCMULTI V SPACE

Singleconstant

PHNFP14A0 (Convertible, Duct)PSNFP14A0 (CST, RAC)

PMNFP 14A0

PMNFP14A0 (Max 16Indoors)PMNFP14A1 (Max 48Indoors)

COMBINATION

For LGAP applied models For LGAP applied models

PQCSB101S0 + PQCSC101S0

PQCSB101S0+PQCSD130A0

or

Vcc, GND

RS485

AC220V

MULTI, Single A

Singleconstant

PHNFP14A0 (Convertible, Duct)PSNFP14A0 (CST, RAC)

PMNFP 14A0

PMNFP14A0 (Max 16Indoors)PMNFP14A1 (Max 48Indoors)

Page 9: GL-AC081forfuture.cz/SOUBORY/KATALOGY/KATALOGY_LG/LG... · PQRCUSA0 PCRCUSZ0 PZRCUSB0 PDRCUSZ0 PQRCUDS0 (White) PQRCUDSOB (Blue) PQRCUDSOS (Silver) Wired Remote Controller Simple

FEATURES

AC Smart16 17C E N T R A L CO N T RO L L E R

PQCSW320A0E

For the mid sized buildings up to 64 or 128 indoor units can be controlled and monitored by touch screen central controller.It's possible to control and monitor the air conditioning system throughweb access, anywhere with PC.

C E N T R A L CO N T RO L L E R

Ce

ntra

l Co

ntro

ller

1 6

17

COMBINATION

AC SmartPQCSW320A0E

AC220V

PHNFP14A0 (Ceiling & Floor, Duct)PSNFP14A0 (CST, RAC)

PHNFP14A0

PMNFP14A0

PMNFP14A0 (Max. 16 Indoors)PMNFP14A1 (Max. 48 Indoors)

Single constant

Ventilation

Single A, MULTI

DC Comm, Line

RS4850.75mm2 X 2C (shield)

Web Access - Remote Management - Error Report via E-mail

Operation Report-Operating Time, Percentage, History

Emergency Interlock-Forced Off

128 Indoor unitsExpansion Kit

Multiple Local Controllers-Master / Slave

Multi Language-English, Italian, Spanish, French, German, Dutch, Russian

Easy Control-Function Lock-Lock Schedule

Comfort Control-Automatic H/C Changeover-Temperature Limit-Temperature Range Restriction-Time Limit Control

AC Smart• 7" Touch Screen / GUI

• Direct Connect to LGAP

DO Kit

• Remote Controller Restriction• Automatic Setting• A/C and Vent.

Easy Software Upgrade by USB

DI RS485

USB

Screen Saver

EmergencyLGAP

Light Pump Motor etc

Cooling

Heating

Schedule Control

It’s possible to set up various automatic operationschedule such as on_off control, operation mode,temperature setting, fan speed.

※ 128 Indoor units Expansion Kit : PQCSE440U0※ DO Kit : PQNFP00T0

History Function

Zone Control Lock Function

Auto Changeover Temperature Limit Function

Operating and error history is saved in AC Smart. So it helps to maintain the system more easily and quickly.

It’s possible to control and monitor indoor units by zone,group or unit

It is automatic operating mode change (cooling or heating)to maintain optimum room temperature, especially inseason change period

This function automatically starts and stops air-conditionerto prevent the building from freezing and overheating.

Various lock functions help to restrict individual controlof indoor units and manage power consumption of air conditioner.

HEAT

Temp

UpperTemperature

SettingTemperature

LowTemperature

Temp. Difference

Change Point (Heat ---> Cool)

Change Point (Cool ---> Heat)

TimeHEATCOOL STOP

TempUpper

Temperature(uT)

uT-4

LowerTemperature(IT)

IT+4

Start Cooling Start Heating

Stop HeatingStop Cooling

TimeSTOPCOOL STOP HEAT

For LGAP applied models

MULTI V PLUS IIMULTI V SYNC IIMULTI V SPACE IIMULTI V MINI

MULTI V PLUSMULTI V SYNCMULTI V SPACE

※ No need of PI 485, when use MULTI V II series outdoor with '08 new indoor units.

Page 10: GL-AC081forfuture.cz/SOUBORY/KATALOGY/KATALOGY_LG/LG... · PQRCUSA0 PCRCUSZ0 PZRCUSB0 PDRCUSZ0 PQRCUDS0 (White) PQRCUDSOB (Blue) PQRCUDSOS (Silver) Wired Remote Controller Simple

Deluxe Central Controller18 19C E N T R A L CO N T RO L L E R

PQCSW502A2

The deluxe central controller can control up to 256 indoor units, very convenienttouch screen and GUI(Graphic User Interface) features makes it user friendly.

Ce

ntra

l Co

ntro

ller

1 8

19

FEATURES

CO N T RO L / M O N I TO R I N G

COMBINATION

Max.no. of indoor units7 inch LCD panelConvenient GUI / Touch screenContol / MonitoringSchedule managementGroup managementUser lock functionSelf-diagnosis functionPeak controlPDI monitoringInternet remote controlVentilation control & monitoring

256 indoor units

Need of PDI

PQCSW502A2

System Control & MonitoringTo check general control and monitoringfunctions of the air conditioner centralcontrol system such as group selection and airconditioner selection, air-conditioner control ,monitor function, etc.1Schedule ControlSetup of a weekly schedule for all, group andindividual air conditioner enables operation ofthe system. Processing through enlist of extraschedule for a year is available.2Ventilator Control (Eco-V)To check general control and monitoringfunctions of the ventilation central controlsystem such as group selection and ventilatorselection, ventilator control, monitorfunction, etc.3Peak ControlTo control the maximum demand power. It has an effect on cutting down power costsby keeping the amount of all the airconditioners consumption lower thanDemand Power authorized 4

Ethernet(Direct UTP cable)

Deluxe central controllerPQCSW502A2

AC220V

PHNFP14A0 (Ceiling & Floor, Duct)PSNFP14A0 (CST, RAC)

PHNFP14A0

PMNFP14A0

PMNFP14A0 (Max. 16 Indoors)PMNFP14A1 (Max. 48 Indoors)

Single constant

Ventilation

Single A, MULTI

CNU ( I-Gateway)PQNFG14B0

HUB

DC Comm, Line

CNU 8

RS4850.75mm2 X 2C (shield)

For LGAP applied models

MULTI V PLUS IIMULTI V SYNC IIMULTI V SPACE IIMULTI V MINI

MULTI V PLUSMULTI V SYNCMULTI V SPACE

※ No need of PI 485, when use MULTI V II series outdoor with '08 new indoor units.

Page 11: GL-AC081forfuture.cz/SOUBORY/KATALOGY/KATALOGY_LG/LG... · PQRCUSA0 PCRCUSZ0 PZRCUSB0 PDRCUSZ0 PQRCUDS0 (White) PQRCUDSOB (Blue) PQRCUDSOS (Silver) Wired Remote Controller Simple

PC Based Central Controller20 21C E N T R A L CO N T RO L L E R

PQCSS513A0

Not only the controlling through PC in local network environment, but also remotecontrol and monitoring of up to 2,048 indoor units can be facilitated using internettechnology.

Ce

ntra

l Co

ntro

ller

20

21

FEATURES

COMBINATION

• OS: Windows XP (include Microsoft Java VM) • CPU: Pentium4 2.2GHz or above • RAM: 256MB or above • HDD: Space with minimum 600MG or more • Web browser: Internet Explorer 5.0 or above

ClassificationProgram installationMax. no. of indoor unitsControl / MonitoringSchedul managementGroup managementUser lock functionSelf-diagnosis functionPeak controlPDI MonitoringInternet remote controlVentilation control & monitoringParts supplied

User S.W. EngineInstall with CD

2048 Indoor units

Need of PDI

PQCSS513A0

CO N T RO L / M O N I TO R I N G

System Control & MonitoringTo check general control and monitoringfunctions of the air conditioner centralcontrol system such as group selection and airconditioner selection, air-conditioner control ,monitor function, etc.1Schedule ControlSetup of a weekly schedule for all, group andindividual air conditioner enables operation ofthe system. Processing through enlist of extraschedule for a year is available.2Ventilation Control (Eco-V)To check general control and monitoringfunctions of the ventilation central controlsystem such as group selection and ventilatorselection, ventilator control, monitorfunction, etc.3Peak ControlTo control the maximum demand power. It has an effect on cutting down power costsby keeping the amount of all the airconditioners consumption lower thanDemand Power authorized 4

CD Remote controller

* PC is not supplied with PC Based Central Controller.

USB Hard lock device

For LGAP applied models

Ethernet(Direct UTP cable)

AC220V

PHNFP14A0 (Ceiling & Floor, Duct)PSNFP14A0 (CST, RAC)

PHNFP14A0

PMNFP14A0

PMNFP14A0 (Max. 16 Indoors)PMNFP14A1 (Max. 48 Indoors)

Single constant

Ventilation

Single A, MULTI

CNU ( I-Gateway)PQNFG14B0

HUB

DC Comm, Line

CNU 8

RS4850.75mm2 X 2C (shield)

MULTI V PLUS IIMULTI V SYNC IIMULTI V SPACE IIMULTI V MINI

MULTI V PLUSMULTI V SYNCMULTI V SPACE

PC Based centralcontrollerPQCSS513A0

※ No need of PI 485, when use MULTI V II series outdoor with '08 new indoor units.

Page 12: GL-AC081forfuture.cz/SOUBORY/KATALOGY/KATALOGY_LG/LG... · PQRCUSA0 PCRCUSZ0 PZRCUSB0 PDRCUSZ0 PQRCUDS0 (White) PQRCUDSOB (Blue) PQRCUDSOS (Silver) Wired Remote Controller Simple

ACP & AC Manager22 23C E N T R A L CO N T RO L L E R

PQCPA11A0E(Without IO) / PQCPB11A0E(With IO)PQCSS520A0E(AC Manager)

Through embedded web control function in ACP one can control andmonitor various functions of air-conditioner such as temperaturesetting, schedule, peak power control, etc.

C E N T R A L CO N T RO L L E R

Ce

ntra

l Co

ntro

ller

2 2

23

COMBINATION

FEATURES

Max.no. of indoor unitsControl / MonitoringSchedule managementLock functionTemperature range restrictionTemperature limit functionAuto Changeover functionHistory functionPeak controlPDI monitoringInterlocking functionPrinting function

4,096 indoor units(16 ACP)

Mode/Temp/Fan speed/Schedule

Monitoring & Error history

Need of PDI Fire sensor, Door sensor, Motion sensor...

System setting, History, PDI

PQCPB11A0E+PQCSS520A0E256 indoor units

Temperature---

Monitoring

Need of PDI --

PQCPA(B)11A0E4,096 indoor units(16 ACP)

Mode/Temp/Fan speed/Schedule

Monitoring & Error history

Need of PDI -

System setting, History, PDI

PQCPA11A0E+PQCSS520A0E

KW

Time

Control / Monitor

New Function Upgrade

Remote Access

Various Controller Combination

Fire Alarm

Stand Alone Operation

Power Proportional Distribution

Peak Power Control

Schedule

ACPPQCPA(B)11A0E

AC ManagerPQCSS520A0E

AC220V

PHNFP14A0 (Ceiling & Floor, Duct) / PSNFP14A0 (CST, RAC)

PHNFP14A0

PMNFP14A0

PMNFP14A0 (Max. 16 Indoors) / PMNFP14A1 (Max. 48 Indoors)

Single constant

Ventilation

Single A, MULTI

DC Comm, Line

Internet

Internet

Korean reference site.

Max. 4,096 Indoor

AC Manager ACP

Multi Area ManagementThe product specially designed for multi area management.-Central control & monitor Max. 4096 indoor units & Max.16 ACP

Application

For LGAP applied models

AC220V

PHNFP14A0 (Ceiling & Floor, Duct) / PSNFP14A0 (CST, RAC)

PHNFP14A0Max.16 ACP

PMNFP14A0

PMNFP14A0 (Max. 16 Indoors) / PMNFP14A1 (Max. 48 Indoors)

Single constant

Ventilation

Single A, MULTI

DC Comm, Line

MULTI V PLUS IIMULTI V SYNC IIMULTI V SPACE IIMULTI V MINI

MULTI V PLUSMULTI V SYNCMULTI V SPACE

MULTI V PLUS IIMULTI V SYNC IIMULTI V SPACE IIMULTI V MINI

MULTI V PLUSMULTI V SYNCMULTI V SPACE

HUB

※ No need of PI 485, when use MULTI V II series outdoor with '08 new indoor units.

Page 13: GL-AC081forfuture.cz/SOUBORY/KATALOGY/KATALOGY_LG/LG... · PQRCUSA0 PCRCUSZ0 PZRCUSB0 PDRCUSZ0 PQRCUDS0 (White) PQRCUDSOB (Blue) PQRCUDSOS (Silver) Wired Remote Controller Simple

BNU-LW Gateway (Building Network Unit-LONWORKS®)24 25C E N T R A L CO N T RO L L E R

PQNFB16A1

Easy interface between BMS and LG Air-conditioner• Independence of BMS under the standard BMS -Operation system based on LNS( LonWorks® Network Service)

PQNFB17B0

Easy interface between BMS and LG Air-conditioner• Independence of BMS under the standard BMS.- Operation system based on BACnet Service.

BNU-BAC Gateway (Building Network Unit-BACnet)C E N T R A L CO N T RO L L E R

Ce

ntra

l Co

ntro

ller

24

25

FEATURES

COMBINATION

(LON MARK CERTIFICATION VERSION 3.3 )

Controlling

On/Off commandOperation mode setting

Fan Speed settingLock setting

Air flow settingSet temp. setting

User mode setting (for only ventilator)

Monitoring items

On/Off status reportOperation mode status report

Fan Speed status reportLock status report

Air flow status reportSet temp. status report

Current Space temp. status reportError status report

User mode status report (for only ventilator)

Controlling

On/Off commandOperation mode setting

Fan Speed settingLock setting

Air flow settingSet temp. setting

User mode setting (for only ventilator)

Monitoring items

On/Off status reportOperation mode status report

Fan Speed status reportLock status report

Air flow status reportSet temp. status report

Current Space temp. status reportError status report

User mode status report (for only ventilator)

Network

LON comm. lineBMS system

PI485

PI485

PHNFP14A0

RS485

Lighting control

Other LON devices

LGAP applied Air-conditioner

Indoor unit : Max. 64 units (Air-conditioner & ventilation)Indoor address : 00 ~ 3F

Remote checking Utility control

Outdoor unit Indoor unit

PQNFB16A1BNU-LW

Ventilation

Simple centralcontroller

AC Smart

Network

BACnet comm. lineBMS system

PI485

PI485

PHNFP14A0

RS485

Lighting control

Other LON devices

LGAP applied Air-conditioner

Indoor unit : Max. 256 units(Air-conditioner & Ventilation)Indoor address : 00~FF

Remote checking Utility control

Outdoor unit Indoor unit

PQNFB17B0BNU-BAC

Ventilation

• Connection to using LONTALK

protocol and LG Air-conditioner protocol• Process ability

- 64 units( including indoors and ventilators)- Valid address for each unit : 0x00 ~ 0x3F

• Self installation verification function using internet (Web server included)- Setting gateway - Diagnosis of communication status on

LG Air-conditioner network• Connection to remote total management system

(LG system)

FEATURES

COMBINATION

BACnet

• Through embedded web control function in BACnetone can access the airconditioner and externaldevices through internet.

• It can control 256 indoor units. ( A/C or Ventilator )• External devices such as fire alarm, motion detector

can be connected to gateway and their function canbe interlinked with airconditioner operation.

For LGAP applied models For LGAP applied models

or

Simple centralcontroller

AC Smart

or

※ No need of PI 485, when use MULTI V II series outdoor with '08 new indoor units. ※ No need of PI 485, when use MULTI V II series outdoor with '08 new indoor units.

Page 14: GL-AC081forfuture.cz/SOUBORY/KATALOGY/KATALOGY_LG/LG... · PQRCUSA0 PCRCUSZ0 PZRCUSB0 PDRCUSZ0 PQRCUDS0 (White) PQRCUDSOB (Blue) PQRCUDSOS (Silver) Wired Remote Controller Simple

PI 48526 27C E N T R A L CO N T RO L L E R

PMNFP14A1 / PMNFP14A0PHNFP14A0 / PSNFP14A0

PI 485 convert the protocol of air conditioner to the RS 485protocol for central controller.

PQNFG14B0

CNU (Central Network Unit) CNU is the interface unit that transforms RS 485 communication ofindoor and outdoor units to ethernet communication to be connectedwith PC or deluxe central controller for a high-quality central control.

CNUC E N T R A L CO N T RO L L E R

Ce

ntra

l Co

ntro

ller

26

27

PI-485 LINE-UP

WIRING DIAGRAM

MODELS APPLIED

EXTERNAL PHOTO: PQNFG14B0

• Model name : PMNFP14A0

• Power : Single phase AC 220V 50/60Hz

• Max. no of the indoor units

that can be connected : 16 units

• Model applied : MULTI V, MULTI, Single A

• Model name : PMNFP14A1

• Power : Single phase AC 220V 50/60Hz

• Max. no of the indoor units that can be

connected : 48 units

• Model applied : MULTI V

• Model name : PHNFP14A0

• Power : Connected with the indoor units

• Max. no of the indoor units that can be

connected : 1 units

• Model applied : Single (Duct, CVT) , Eco V

• Model name : PSNFP14A0

• Power : Connected with the indoor units

• Max. no of the indoor units that can be

connected : 1 units

• Model applied : Single (RAC, PAC, CST)• Power: single phase 220V AC 50/60Hz

Model name

PQNFG14B0

Models appliedMaximum no. of outdoor units that can be connected per CNU

Deluxe Central Controller PC Based Central Controller

8 8 For LGAP applied models

PI485 ConnectionBUS_A : PI485 A terminal[+]BUS_B : PI485 B terminal[-]

AC/DC Adaptor

Adaptor Connection DC 9V (supplied)

RJ45 ConnectorConnected with the HUB

Deluxe Central Controller

DO Kit

PQNFP00T0

Do Kit is connected between ACP (AC Smart) and external devices.So ACP(AC Smart) can start and stop external devices such as light,pump, motor, etc.

※ MULTI V II Series don’t need any other PI 485 because MULTI V II series have PI 485 in its outdoor unit PCB.

( , , , &’08 New indoor units)

L N

Power of LoadBUS _ A

BUS _ B

Light Pump Motor etcACP or AC Smart

Page 15: GL-AC081forfuture.cz/SOUBORY/KATALOGY/KATALOGY_LG/LG... · PQRCUSA0 PCRCUSZ0 PZRCUSB0 PDRCUSZ0 PQRCUDS0 (White) PQRCUDSOB (Blue) PQRCUDSOS (Silver) Wired Remote Controller Simple

Electronic AccessoryA wide range of electronic accessories help to use our air conditioning system more coveniently.

Ele

ctro

nic

Ac

ce

ssory

28

29

PDI

Dry Cntact

Cool/Heat Selector

Remote TemperatureSensor

Zone Controller

ElectronicThermostat

CTI

Low Ambient Kit

Telecom ShelterController

30

32

33

34

35

36

37

38

39

Page 16: GL-AC081forfuture.cz/SOUBORY/KATALOGY/KATALOGY_LG/LG... · PQRCUSA0 PCRCUSZ0 PZRCUSB0 PDRCUSZ0 PQRCUDS0 (White) PQRCUDSOB (Blue) PQRCUDSOS (Silver) Wired Remote Controller Simple

PDI30 31E L E C T RO N I C ACC E SSO RY

PQNUD1S00

For the multi indoor units connected to an outdoor unit, the individual unit’s and total system power consumption can be displayed on the device. This system can also be connected to a remote metering system.

E L E C T RO N I C ACC E SSO RY

Ele

ctro

nic

Ac

ce

ssory

30

31

POWER INDICATOR OVERVIEW

COMBINATION

• This device displays the power consumed for eachindoor air conditioner unit that shares an outdoor unit.

• The power consumed by each indoor unit connectedwith the joint power line is indicated on the device.

• The information of the power distributed can be sent ona real-time basis through the remote metering system.

FEATURES

• Accumulated total power consumption indicated• Accumulated/Current power consumption of each indoor unit indicated.• Accumulated power consumption by month indicated• Max. connectable no. of indoor units : 48 indoor units• 1 PDI per 1 outdoor unit• Power failure-proof function : Data back up on EEPROM even if power turns off• Connectable to PC based central controller• Simple connection with the remote metering system (RS485 approach)• Power distribution indication formula

31

1

2

LCD indication window

3 Label indicating the locations of each indoor unit

2 Key operation section

*Weight by room: Weight calculated based on the temperature set by room, mode and operating time.

= ×Power used per roomTotal power consumed

for an external unitweight by room

total weight

(under 16 indoor units)

Pluse Out(1,2,4,5,8,10W/pulse)AC 200V~240V 50/60Hz

Pluse Out(1,2,4,5,8,10W/pulse)AC 200V~240V 50/60Hz

(Over 16 Indoor units)

In the case of , don’t need PI-485 ( , , , &’08 New indoor units)

[Installation without PC based central controller]

PQNUD1S00

RS485

RS485

Digital WHM(Local Purchase)

Digital WHM(Local Purchase)

PQNUD1S00

AC220V

AC220V

or

or

PMNFP14A0 : (under 16 indoor units)

PMNFP14A1 : (over 16 indoor units)

PMNFP14A0 : (under 16 indoor units)

PMNFP14A1 : (over 16 indoor units)

Pluse Out(1,2,4,5,8,10W/pulse)AC 200V~240V 50/60Hz

[Installation with PC based central controller]

PQNUD1S00

PQNFG14B0 PQCSS513A0

RS485

Digital WHM(Local Purchase)

AC220V

In the case of , don’t need PI-485 ( , , , &’08 New indoor units)

Page 17: GL-AC081forfuture.cz/SOUBORY/KATALOGY/KATALOGY_LG/LG... · PQRCUSA0 PCRCUSZ0 PZRCUSB0 PDRCUSZ0 PQRCUDS0 (White) PQRCUDSOB (Blue) PQRCUDSOS (Silver) Wired Remote Controller Simple

Dry Contact32 33E L E C T RO N I C ACC E SSO RY

PQDSA(B) / PQDSB1 / PQDSBC

It is connected between indoor units and external device, so it can be used for various purpose

Cool/Heat SelectorE L E C T RO N I C ACC E SSO RY

PRDSBM

This switch enables selection of heating, cooling or fan mode. So it can preventthat cooling & heating mixing error occurs during the change of season.

Ele

ctro

nic

Ac

ce

ssory

3 2

33

FEATURES FEATURES

MODELS APPLIED

WIRING DIAGRAMPARTS DESCRIPTION

System Structure

Dry contact(Contact point linked

with Outer part)

CN-POWER : AC 220V connectorCN-CC : MAINPCB connectorCN-DRY(L) : DRY CONTROLLER connectorCN-DRY(SIG) : DRY CONTROLLER connector

CN-DRY(ERROR CHECK) : ERROR check display connectorCN-DRY(OPER STATE) : Operation display connector

Key Switch Lighting Sensor Fire Alarm Timer MotionDetect Sensor

Door Chek Sensor

Contact pointPower inputVoltage / Non voltage inputOn_Off controlLock / UnlockFan speed settingThermo offEnergy savingTemperature settingError monitoringOperation monitoring

PQDSBCPQDSA(B)

1 Control point AC 220V from outside power source

-

-----

PQDSB1

1 Control point AC 24V from outside power source

-

-----

2 Control pointsDC 5V&12V from indoor unit PCB

※ Refer to each model PDB for applicable models.※ With case model : PQDSB, PQDSB1, PQDSBC

Without case model : PQDSA

<PQDSA(B) / PQDSB1>

CN_INDOOR2 : Connector for Main <-> Dry ContactCN_INDOOR1 : PI 485 ConnectorCHANGE_OVER_SW : Switch for selecting junction signal - Voltage(5V~12V) or Non VoltageCN_CONTROL : Connector for input junction signalCONTROL_MODE_SW : Switch for selecting control modeSETTING_SW : Switch for selecting Dry Contact setting functionTEMP_SETTING : Switch for setting desired temperatureCN_OUT(O1,O2) : Terminal Block for displaying main operation CN_OUT(E3,E4) : Terminal Block for displaying main errorDISPLAY_LED : LED for displaying status of Dry ContactRESET_SW : Reset Switch

<PQDSBC>

• Connect terminals(①①, ②②, GND) on the back side of Cool/Heat Selector toterminals (①①, ②②, GND) of Outdoor Main PCB.

※ Max. communication line length : 300m

Fan Mode

CoolingFan Mode

Heating

• Indoor unit control without central controller• Select operation mode : Cooling, Heating, Fan mode• Mode lock for cooling & heating mixing error-proof during the change of season.

Page 18: GL-AC081forfuture.cz/SOUBORY/KATALOGY/KATALOGY_LG/LG... · PQRCUSA0 PCRCUSZ0 PZRCUSB0 PDRCUSZ0 PQRCUDS0 (White) PQRCUDSOB (Blue) PQRCUDSOS (Silver) Wired Remote Controller Simple

Remote Temperature Sensor34E L E C T RO N I C ACC E SSO RY

PQRSTA0

Sensor for detecting the room temperature.

FEATURES

• It can help to detect the exact room temperature at the optimal position.

MODELS APLLIED

• Ceiling cassette type• Ceiling concealed duct type

PARTS INCLUDED• Remote temperature sensor• Extension cable (15m)• Manual

WIRING DIAGRAM

1. Wire to the control box in the indoor unit by removing the

existing thermistor and connect the extension cable its

place.

2. Cut the extension cable to the appropriate length and

connect the screw terminal of the remote sensor.

3. In the case of wired remote controller installed, set the

temperaturesensing slide s/w at MAIN mode.

Connector

Indoor unit

Remote TemperatureSensor

Extension cable

Screw terminal connection

Zone Controller35E L E C T RO N I C ACC E SSO RY

ABZCA

Controls air conditioning in up to 4 zones.

FEATURES

• Controls different zones (up to 4 zones)• Maintain proper temperature of each zone• Auto variation of dampers• Auto control of fan speed

MODELS APPLIED

• Ceiling Concealed Duct ( High Static Pressure)※ Refer to each model PDB for applicable modles

PARTS INCLUDED

WIRING DIAGRAM

COMPONENTS

Factory supplied :•Zone controller PCB (1EA) •Transformer (1EA) •Case (1EA) •Cover (1EA)

•Main lead wires (1EA) •Screws (1EA) •Holder (4EA) •Installation manual (1EA)

Purchased locally (reference siemens, honneywell)•Damper Motor •Thermostat • Damper

ROOM1temperaturesensor

Auto Damper

Auto Damper

Auto Damper

Auto Damper

Zone Control

sub PCB

ROOM2temperaturesensor

ROOM3temperaturesensor

ROOM4temperaturesensor

Ele

ctro

nic

Ac

ce

ssory

3 4

35

Page 19: GL-AC081forfuture.cz/SOUBORY/KATALOGY/KATALOGY_LG/LG... · PQRCUSA0 PCRCUSZ0 PZRCUSB0 PDRCUSZ0 PQRCUDS0 (White) PQRCUDSOB (Blue) PQRCUDSOS (Silver) Wired Remote Controller Simple

36

Electronic ThermostatE L E C T RO N I C ACC E SSO RY

AQETC

Simple and easy control of system.

Ele

ctro

nic

Ac

ce

ssory

3 6

37

FEATURES

• Less complicated in operation (simple controls).• Built in thermister for better control.

MODELS APPLIED

NAME AND DESCRIPTION OF THE SYSTEM

WIRING DIAGRAM

• Ducted Split ( 3~5RT) / Single Package (3~ 5RT)※ Refer to each model PDB for applicable models

FEATURES

• Transfer each local contact signal from Thermostat to Unitary product

MODELS APPLIED

PARTS INCLUDED

WIRING DIAGRAM

• Unitary

R : 24V(+)C : 24V(-)G : FanY1 : Cooling changeoverW1 : Heating changeoverY1 : Comp1Y2 : Comp2EM : EmergencyW1 : Heater1W2 : Heater2

• CTI PCB(1EA) • 11Pin Cable(to connect with Unitary PCB)

• Transformer • 3Pin Cable(to connect with Unitary PCB)

• Manual

CTI37E L E C T RO N I C ACC E SSO RY

PKFC0

Communicate with other Mechanical Thermostat and Unitary product

Page 20: GL-AC081forfuture.cz/SOUBORY/KATALOGY/KATALOGY_LG/LG... · PQRCUSA0 PCRCUSZ0 PZRCUSB0 PDRCUSZ0 PQRCUDS0 (White) PQRCUDSOB (Blue) PQRCUDSOS (Silver) Wired Remote Controller Simple

38

Low Ambient KitE L E C T RO N I C ACC E SSO RY

AQLA

To cool you even in winter.

FEATURES

• Depending on the condensing temperature, speed of outdoor fan is varied automatically while compressor is ON.• Maintains cooling function for very low ambient temperature such as (-5°C). • Specific installation requirements - Gymnasium, Control rooms, Machine rooms, Computer rooms

• Simple and easy to install • Used only for cooling mode

MODELS APPLIED TO

• Convertible, Ceiling Concealed Duct • Single split• Ceiling Cassette (Refer to each model PDB for applicable models)• Multi Split(Specific models)

PARTS INCLUDED

WIRING DIAGRAM

• AQLA fan speed controller 1EA• Sensor assembly 1EA• Buckle-clip 3EA• Adhesive insulation, 20mm x 80mm 1EA• Tie wrap,100mm 2EA• Instruction manual 1EA• Screw 3EA

Main power fromoutdoor PCB

Power supplyTo fans

Connection with4 way valve (1)

Connection withtemperature sensorprovided

Connection with 4 wayvalve(2)> For multi system

N NL L

Ele

ctro

nic

Ac

ce

ssory

38

39

• Automatically start and stop air conditioner by turns• Display internal temperature of shelter on LCD• Sense water leakage and humidity• Control ventilation fan.• Fire alarm function• Error display• Low ambient function• Electric failure compensation

Telecom Shelter Controller39E L E C T RO N I C ACC E SSO RY

PQCSA001T0

This controller is suitable for telecom shelter. It can control and monitor air conditionerin telecom shelter.

FEATURES

COMBINATION

Auto Rotation of Air conditioner

Page 21: GL-AC081forfuture.cz/SOUBORY/KATALOGY/KATALOGY_LG/LG... · PQRCUSA0 PCRCUSZ0 PZRCUSB0 PDRCUSZ0 PQRCUDS0 (White) PQRCUDSOB (Blue) PQRCUDSOS (Silver) Wired Remote Controller Simple

••

••

•••••

Mechanical AccessoryFor comfort and convenience.

Me

ch

an

ica

l Ac

ce

ssory

40

41

ARTCOOL Panel

Electric Heater

Plasma Air Purifier

Drain Pump Kit

Suction Grille / Canvas

Auto Elevation Grille

Cassette Cover

Air Guide

42

44

46

47

48

49

50

51

Mechanical Accessory Line up and Application

ARTCOOL Panel

Electric Heater

Plasma Air Purifier

Drain Pump Kit

Suction Grille / Canvas

Auto Elevation Grille

Plasma Kit

Cassette Cover

Air guide

ARTCOOL indoor unit

Single package / Ducted split

Ceiling concealed duct(High static)

Ceiling concealed duct

Ceiling concealed duct (Built-in)

4 Way Cassette

4 Way Cassette

4 Way Cassette

Outdoor unit

Model

••••

••••

Single Type Multi Type Multi V Type Remark

Page 22: GL-AC081forfuture.cz/SOUBORY/KATALOGY/KATALOGY_LG/LG... · PQRCUSA0 PCRCUSZ0 PZRCUSB0 PDRCUSZ0 PQRCUDS0 (White) PQRCUDSOB (Blue) PQRCUDSOS (Silver) Wired Remote Controller Simple

Me

ch

an

ica

l Ac

ce

ssory

42

43

ACCESSORY MODEL NAME

DETAILS OF MODEL NAME

43

GoghSisley

White woodBlue

WoodMetalMirrorCherrySilverRed

GoldWhite Silver

Type

ChassisColor

PSAPPAA10PSAPPAS10PSAPPCW10PSAPPCB10PSAPPCD10PSAPPCM10

PSAPVCW10PSAPVCB10PSAPVCD10PSAPVCM10

PSAPUCW10PSAPUCB10PSAPUCD10PSAPUCM10PSAPUCR10PSAPUCC10

PSAPZCW10PSAPZCB10PSAPZCD10PSAPZCM10PSAPZCR10PSAPZCC10

PSAP3CW10PSAP3CB10PSAP3CD10PSAP3CM10PSAP3CR10PSAP3CC10

PSAPECB10

PSAPECR10

PSAPECV10

PSAP8CB10

PSAP8CR10

PSAP8CV10 PSAPFCV11PSAPFCE11PSAPFCG11PSAPFCH11

SP2 SV2 SU SZ S3 SE S8 SF

42

ARTCOOL PanelM E C H A N I C A L ACC E SSO RY

A unique blend of art and colors.

MODELS APPLIED TO

• All ARTCOOL models

ARTCOOL Panel

ARTCOOL Wide

ARTCOOL SF chassis

ARTCOOL Mirror

ARTCOOL Wide Type

White wood Blue Wood Metal

ARTCOOL Panel Type

ARTCOOL SF Chassis

Wood MetalBlueWhite wood

Silver Red Gold White silver

Gogh Sisley

White wood Blue Wood

Metal Mirror Cherry

Blue Mirror Silver

ARTCOOL Mirror Type

1 2 3 4 5 6 7 8 9

P S A P P C R 1 0

Serial no.

Number of panel

* Color

Chassis

ARTCOOL front panel

Single split wall Mounted air conditioner

Parts

• AA : Gogh• AS : Sisley• CB : Blue• CC : Cherry• CD : Wood• CE : Red

• CG : Gold • CH : White Silver• CM : Metal• CR : Mirror• CV : Silver• CW : White Wood

* Panel color

Page 23: GL-AC081forfuture.cz/SOUBORY/KATALOGY/KATALOGY_LG/LG... · PQRCUSA0 PCRCUSZ0 PZRCUSB0 PDRCUSZ0 PQRCUDS0 (White) PQRCUDSOB (Blue) PQRCUDSOS (Silver) Wired Remote Controller Simple

44

Electric HeaterM E C H A N I C A L ACC E SSO RY

Me

ch

an

ica

l Ac

ce

ssory

44

45

FEATURES

• Provides quick and additional heating.

Single Package• Electric heater (1EA)• Installation manual (1EA)• Heater control box (1EA)• Screws

Ducted Split• Electric heater (1EA )• Hexagonal nut (6EA)• Hexagonal bolt M6, L14 (16EA)• Installation Manual (1EA)

MODELS APPLIED TO

• Single package• Ducted split(refer PDB for applicable models)

DETAILS OF MODEL NAME

PARTS SUPPLIED

ACCESSORY MODEL NAME AND ELECTRICAL DATA

1 2 3 4 5 6 7 8 9

L K A E H 0 5 2 L

L : Large capacity heater

Voltage

Heater (kW)

Accessory nameEH : Electric heater

Accessory

ProductLK : Single packageLN : Ducted split

45

2 -1ø 220VB-3ø 220V8 -3ø 380V

1 2 3 4 5 6 7 8 9

A K E H 0 5 2 1 A

Chassis

Stage

Voltage

Heater (kW)

Accessory nameEH : Electric heater

ProductLK : Single packageLN : Ducted split

Accessory

2 -1ø 220VB-3ø 220V8 -3ø 380V

Single Package : LKAEH, AKEHDucted Split : ANEH

Gives heating to keep you warm.

Single Package

Ducted Split

50 / 60Hz

Single Package

3~5RT3~5RT

6.25~12.5RT6.25~17.5RT15~17.5RT20~25RT

3~5RT3~5RT

6.25~12.5RT7.5~17.5RT7.5~17.5RT20~25RT

Ton

LKAEH052LKAEH102LKAEH09BLKAEH18BLKAEH36BLKAEH36BLAKEH0521AAKEH1021ALKAEH098LKAEH188LKAEH368LKAEH368L

ModelName

3.6/5.07.2/10.07.8/9.0

15.6/18.031.2/36.031.2/36.0

5.010.0

7.5/9.015.1/18.0

30.2/36.030.2/36.0

510918

18+1836510918

18+1836

111122111122

208~240/1208~240/1208~240/3208~240/3208~240/3208~240/3

240/1240/1

380~415/3380~415/3380~415/3380~415/3

27.6/32.247.7/55

30.4/35.156.2/64.897.1/112.197.1/112.1

34.257.0

26.0/27.237.5/39.5

100.2/120.3108.6/160.4

60/6060/6060/6060/60125/125125/12560/6060/6060/6060/60

150/150150/150

60/6060/6060/6060/60125/125125/12560/6060/6060/6060/60

150/150150/150

27.6/32.247.7/55

30.4/35.156.2/64.897.1/112.197.1/112.1

--

31.0/32.242.5/44.5

106.2/126.3114.6/136.4

60/6060/6060/6060/60125/125125/125

--

60/6060/60

150/150150/150

60/6060/6060/6060/60125/125125/125

--

60/6060/60

150/150150/150

HeaterOutput(kW)

Min/Max. Volts

Heater Rating(kW)

ControlStages

Voltage(V/ø)

Standard indoor fan motor Over size indoor motor

M.C.A M.F.S M.C.B M.C.BM.F.SM.C.A

Ducted Split

3~5RT3~5RT

6.25~12.5RT6.25~17.5RT

15~20RT15~20RT3~5RT3~5RT

6.25~12.5RT6.25~12.5RT

15~20RT15~20RT

Ton

ANEH0521AANEH1021AANEH09B1BANEH18B1BANEH18B1CANEH36B2CANEH0581AANEH0981AANEH0981BANEH1881BANEH1881CANEH3682C

ModelName

3.6/5.07.2/10.07.8/9.0

15.6/18.015.6/18.031.2/36.0

5.09.09.018.018.036.0

51091818

18+185991818

18+18

111112111112

208~240/1208~240/1208~240/3208~240/3208~240/3208~240/3380~415/3380~415/3380~415/3380~415/3380~415/3380~415/3

27.6/32.247.4/55

30.4/35.150.9/58.756.2/64.897.1/112.128/33.628/33.632.5/3945/54

61.8/7472/86.4

60/6060/6060/6070/7070/70

125/125253545607090

60/6060/6060/6070/7070/70

125/125253545607090

27.6/32.247.7/55

30.4/35.150.9/58.762.4/72.0103.4/119.3

28/33.628/33.632.5/3945/54

61.8/7472/86.4

60/6060/6060/6070/7080/80125/12535/3535/3545/4560/6070/7090/90

60/6060/6060/6070/7080/80125/12535/3535/3545/4560/6070/7090/90

HeaterOutput(kW)

Min/Max. Volts

Heater Rating(kW)

ControlStages

Voltage(V/ø)

Standard indoor fan motor Over size indoor motor

M.C.A M.F.S M.C.B M.C.BM.F.SM.C.A

*MCA : Minimum current ampere / MFS : Maximum fuse size / MCB : Maximum circuit breaker

*MCA : Minimum current ampere / MFS : Maximum fuse size / MCB : Maximum circuit breaker

Page 24: GL-AC081forfuture.cz/SOUBORY/KATALOGY/KATALOGY_LG/LG... · PQRCUSA0 PCRCUSZ0 PZRCUSB0 PDRCUSZ0 PQRCUDS0 (White) PQRCUDSOB (Blue) PQRCUDSOS (Silver) Wired Remote Controller Simple

46

Plasma Air Purifier Drain Pump KitM E C H A N I C A L ACC E SSO RY

ABPAHH / ABPAHCABPAGH / ABPAGCABPAEH / ABPAEC, ABPARH / ABPARC

Clean and healthy living.

Me

ch

an

ica

l Ac

ce

ssory

46

47

FEATURES

• Provide odor free, dust free, allergy free, clean & healthy air.• Remove microscopic contaminants, dust, house mites, pollen and pet fur to help prevent allergic diseases

like asthma.• Plasma air purifier assembly (AC 220~240V, 50/60Hz)

• Plasma air Purifier assembly(1EA)• Installation manual(1EA)• Screws M4(12EA)• Wired remote controller(1EA)

MODELS APPLIED TO

• Ceiling concealed duct _ High static type (refer PDB for applicable models)

ACCESSORY MODEL NAME

DETAILS OF MODEL NAME

PARTS SUPPLIED

DIMENSION

1 2 3 4 5 6

A B P A H C

Type (H : H/P, C : C/O)

Chassis

Accessory namePlasma Air Purifier

Ceiling concealed duct

Accessory

1 2 3 4 5

A B D P G

Chassis

Accessory nameDrain Pump Kit

Ceiling concealed duct

Accessory

47M E C H A N I C A L ACC E SSO RY

ABDPEABDPGABDPT

Effectively drains out condensed water.

ABPAHHABPAHCABPAGHABPAGCABPAEH/ABPARHABPAEC/ABPARC

Heat pumpCooling onlyHeat pumpCooling onlyHeat pumpCooling only

TypeModel NameCapacity (Btu/h)

18K 24K 30K 36K 42K 48K 60K

Model

ABPAHHABPAHC

ABPAGHABPAGC

ABPAEHABPAECABPARHABPARC

785

1,092

1,235

230

260

350

180

180

180

Dimension

W H D

FEATURES

• In some places where natural drainage is not possible drain pump is very useful to pumps out condensedwater from indoor unit.

• Drain pump assembly (AC 220~240V, 50/60Hz)

For G/H/R/T Chassis Models :• Drain pump assembly(1EA)

(AC 220~240V,50/60Hz,400CMM) • Screw(4EA)• Cap(1EA)• Installation manual(1EA)

For E Chassis Models :• Drain pump assembly(1EA)

(AC 220~240V,50/60Hz,400CMM) • Elbow (ø32)(1EA) • Hose(1EA)• Tie wrap(2EA) • Screw(10EA)• Rubber(1EA) • Installation manual(1EA)

MODELS APPLIED TO

• Ceiling concealed duct (refer PDB for applicable models)

ACCESSORY MODEL NAME

DETAILS OF MODEL NAME

PARTS SUPPLIED

APPLICATION

Multi V TypeMulti TypeSingle Type

Model Name

Default Default

E Chassis

ABDPE

G/H/R Chassis

ABDPG

Default

T Chassis

ABDPT

(Unit : mm)

Page 25: GL-AC081forfuture.cz/SOUBORY/KATALOGY/KATALOGY_LG/LG... · PQRCUSA0 PCRCUSZ0 PZRCUSB0 PDRCUSZ0 PQRCUDS0 (White) PQRCUDSOB (Blue) PQRCUDSOS (Silver) Wired Remote Controller Simple

48

Suction Grille / CanvasM E C H A N I C A L ACC E SSO RY

PBSGB30 / PBSGB40PBSC30 / PBSC40

High flexibility for a wide variety of applications

Me

ch

an

ica

l Ac

ce

ssory

48

49

FEATURES

• High external static pressure facilitates unit use with flexible ducts of varying lengths.• When using suction panel, unit requires only 270mm of ceiling space.• Blends unobtrusively with any interior decoration.

For the suction grille :• Suction panel with air filter (1EA)• Suction panel fix bolt M5x18 (4EA)• Installation manual (1EA)

• For suction grille

For the suction canvas :• Air suction canvas (1EA)• Screws for air suction canvas (4EA)• Adjusting chain (4EA)• Screws for adjusting chain (8EA)• Installation manual (1EA)

MODELS APPLIED TO

ACCESSORY MODEL NAME

DETAILS OF MODEL NAME DIMENSION

PARTS SUPPLIED APPLICATION

49

Grille

Canvas

PBSGB30PBSGB40PBSC30PBSC40

Model NameTypeCapacity (Btu/h)

7K 9K 12K

PBSGB30

PBSGB40

15K 18K 24K

• Ceiling concealed duct _ Built-in type(refer PDB for applicable model)

MODELS APPLIED TO

• 4 Way cassette_Single, Multi V II(refer PDB for applicable models)

• Auto elevation grille kit • Install the kit inside indoor unit

• Install the front panel and the Inlet grille

• Operate the autoelevation grille by thewireless remotecontroller

• Easy maintenance

• Inlet Grille (1EA)• Auto elevation grille kit (1EA)• Wireless Remote Controller (1EA)• Screws (4EA)• Installation manual (1EA)

C

A

B AB

C

Auto Elevation GrilleM E C H A N I C A L ACC E SSO RY

PTEGM0

Easy filter cleaning with elevation grille

FEATURES

DETAILS OF MODEL NAME

APPLICATION

PARTS SUPPLIED

Auto Horizontal Control4-Point Support Structure Auto Bottom DetectionMemory for user’s level

A

910

1188

B

359

359

C

56

56

PBSC30

PBSC40

A

821

1100

B

274

274

C

42~250

42~250

1 2 3 4 5 6 7

P B S G B 3 0

Serial Number

Chassis

Bottom Suction

Suction Grille

Duct

Part

• For suction canvas1 2 3 4 5 6

P B S C 3 0

Serial Number

Chassis

Suction Canvas

Duct

Part

1 2 3 4 5 6

P T E G M 0

Serial No.

Chassis

Elevation Grille Kit

Ceiling Cassette

Part

max. 4.5m

STOP

Memory

(Unit : mm) (Unit : mm)

Page 26: GL-AC081forfuture.cz/SOUBORY/KATALOGY/KATALOGY_LG/LG... · PQRCUSA0 PCRCUSZ0 PZRCUSB0 PDRCUSZ0 PQRCUDS0 (White) PQRCUDSOB (Blue) PQRCUDSOS (Silver) Wired Remote Controller Simple

Plasma Kit

PTPKM0

Plasma air purifying system

50M E C H A N I C A L ACC E SSO RY

FEATURES

• It can remove microscopic contaminants and dust and house mites, pollen, pet fur to help prevent allergic diseases like asthma.

MODELS APPLIED TO

• 4Way cassette - Single Multi V II(refer PDB for applicable models)

• Plasma Kit (1EA)• Screws• Installation Manual (1EA)

51

Air GuideM E C H A N I C A L ACC E SSO RY

PQAGA

Easy air discharge at odd places.

FEATURES

• Converts vertical discharge into horizontal discharge.• Designed for outdoor discharge air.• Direction of air discharge can be changed by simple installation.• Installation flexibility• Light weight

MODELS APPLIED TO

• MULTI V type, MULTI type, Single A (UY, UW Chassis)

DETAILS OF MODEL NAME

DIMENSION APPLICATION

1 2 3 4 5

P Q A G A

Chassis

Air Guide

Common Using

Part

Me

ch

an

ica

l Ac

ce

ssory

50

51

Cassette Cover

PTDCD / PTDCD1 / PTDCM

Maintains the ceiling elegance.

FEATURES

• Specially designed for indoor unit.• Covers the side area of cassette.• Gives elegant looks.

• Light weight.• Suitable when false ceiling is unavailable.

MODELS APPLIED TO

ACCESSORY MODEL NAME

• Ceiling cassette - 4Way(TD, TD1, TH, TP, TN, TM)

PARTS SUPPLIED

• Cover A (4EA), Cover B (4EA)• Cover C (4EA), Cover D (4EA)• Screws• Installation Manual (1EA)

PTDCDPTDCD1PTDCM

PT-CD0, PT-CD1, PT-HD0, PT-HD1PT-CDA1, PT-CDC1, PT-HDA1, PT-HDC1

PT-UMC

Model Name Front Panel

DETAILS OF MODEL NAME

1 2 3 4 5 6

P T P K M 0

Serial No.

Chassis

Plasma Kit

Ceiling Cassette

Part

PARTS SUPPLIED

Page 27: GL-AC081forfuture.cz/SOUBORY/KATALOGY/KATALOGY_LG/LG... · PQRCUSA0 PCRCUSZ0 PZRCUSB0 PDRCUSZ0 PQRCUDS0 (White) PQRCUDSOB (Blue) PQRCUDSOS (Silver) Wired Remote Controller Simple

Piping AccessoryGlobal No.1 seller, LG Air Conditioner!For comfort and convenience.

Pip

ing

Ac

ce

ssory

5 2

53

Y Branch & HeaderBranch (Synchro)

Branch Distributor

Heat Recovery Unit

Y Branch & Branch Kit(Multi Fdx)

Y Branch & Header Branch(Multi V)

54

56

58

60

61 •

••

Piping Accessory Line up and Application

Y Branch and Header

Branch(Synchro)

Branch Distributor (Multi)

Heat Recovery Unit

Y Branch and Branch Kit

(Multi)

Y Branch and Header

Branch(Multi V)

Synchro

Multi Mdx / Multi Fdx

Multi V Sync

Multi Fdx

Multi V Plus / Multi V Sync

Multi V Space / Multi V Mini

Model

Synchro Type Multi Type Multi V Type Remark

Page 28: GL-AC081forfuture.cz/SOUBORY/KATALOGY/KATALOGY_LG/LG... · PQRCUSA0 PCRCUSZ0 PZRCUSB0 PDRCUSZ0 PQRCUDS0 (White) PQRCUDSOB (Blue) PQRCUDSOS (Silver) Wired Remote Controller Simple

54

Y Branch and Header BranchP I P I N G ACC E SSO RY

Pip

ing

Ac

ce

ssory

54

55

55P I P I N G ACC E SSO RY

FEATURES

ACCESSORY MODEL NAME

PIPING DIAGRAM

• Various Y-branch pipe of different capacities make Synchro installation much easier.• Y-branch and header branch for both gas and liquid are provided.• Insulation material is also provided for covering the branches.

• Synchro

MODELS APPLIED TO

Refrigerant distribution channel.

Gas Pipe

Liquid Pipe

( Synchro )

2 branch 3 branch 4 branch

2 Units

3 Units

4 Units

Connectable of Indoor Units Models Liquid PipeGas Pipe

PMUB 11A

PMUB 23A

PMUB 112A

PMUB 122A

PMUB 111A

PMUB 1111A

( 1 : 1 )

( 2 : 3 )

( 1 : 1 : 2 )

( 1 : 2 : 2 )

( 1 : 1 : 1 )

( 1 : 1 : 1 : 1 )

( 1 : 1 )

( 2 : 3 )

( 1 : 1 : 2 )

( 1 : 2 : 2 )

( 1 : 1 : 1 )

( 1 : 1 : 1 : 1 )

PMUB11A, PMUB 23A (2units)PMUB112A, PMUB122A, PMUB111A (3units)PMUB1111A (4units)

Page 29: GL-AC081forfuture.cz/SOUBORY/KATALOGY/KATALOGY_LG/LG... · PQRCUSA0 PCRCUSZ0 PZRCUSB0 PDRCUSZ0 PQRCUDS0 (White) PQRCUDSOB (Blue) PQRCUDSOS (Silver) Wired Remote Controller Simple

56

Branch DistributorP I P I N G ACC E SSO RY P I P I N G ACC E SSO RY

Pip

ing

Ac

ce

ssory

56

57

FEATURES

SPECIFICATION

DETAILS OF MODEL NAME

PARTS SUPPLIED

• Distribution of refrigerant to various indoor units.• 3 models (2, 3, 4 indoor units)• Consists of LEVs inside it• Controlling PCB inside the unit• Internally insulated (prevents any chances of drainage)• Flare joints for easy and clean installation• Compact design (low height)• Flexible installation

MODELS APPLIED TO INSTALLATION• systems• systems

(refer PDB for applicable models)

57

PMBD3620, PMBD5420LPMBD3630, PMBD7230, PMBD5430LPMBD3640, PMBD5440L

Effective and unique way of refrigerant distribution.

Connectable Number of Indoor unitCapacity (Btu/h)Casing colorPower source

Power consumption (W)Running current (A)Dimensions (W x H x D) (mm)Packing dimension (W x H x D) (mm)Net weightConnecting cable Indoor unit No. x mm2

Outdoor unit No. x mm2

Piping connection liquid (mm)(Outdoor unit) Gas (mm)Piping connection Liquid (mm)(Indoor unit) Gas (mm)Parts Hanger (EA)

Screw (EA)Manual (EA)

PMBD3640 PMBD3630 PMBD3620 PMBD72301~4

7k/9k/12k/18k/24kPaintingless

1ø, 50/60Hz,220~240/220V

100.05

302x143x252422x202x300

5.04x0.754x0.75

9.5219.05

6.35x4EA9.52x4EA

481

1~37k/9k/12k/18k/24k

Paintingless1ø, 50/60Hz,

220~240/220V10

0.05302x143x252422x202x300

4.94x0.754x0.75

9.5219.05

6.35x3EA9.52x3EA

481

1~27k/9k/12k/18k/24k

Paintingless1ø, 50/60Hz,

220~240/220V10

0.05302x143x252422x202x300

4.84x0.754x0.75

9.5219.05

6.35x2EA9.52x2EA

481

1~318k/24k/30k/36k

Paintingless1ø, 50/60Hz,

220~240/220V10

0.05302x143x252422x202x300

5.04x0.754x0.75

9.5219.05

6.35x3EA12.7,15.88x2EA

481

PMBD3620,PMBD5420L

PMBD3630,PMBD7230,PMBD5430L

PMBD3640,PMBD5440L

No brazing Just flaring

• Position of branch distributor in the system• PDB (Select) - Installation PDB

(R22)

(R410A)

Connectable Number of Indoor unitCapacity (Btu/hr)Casing colorPower source

Power consumption (W)Running current (A)Dimensions (W x H x D) (mm)Packing dimension (W x H x D) (mm)Net weightConnecting cable Indoor unit No. x mm2

Outdoor unit No. x mm2

Piping connection liquid (mm)(Outdoor unit) Gas (mm)Piping connection Liquid (mm)(Indoor unit) Gas (mm)Parts Hanger (EA)

Screw (EA)Manual (EA)

PMBD5440L PMBD5430L PMBD5420L1~4

12,000~54,000Paintingless1ø, 50/60Hz

220~240/220V10

0.05302x143x252422x202x300

5.04x0.754x0.75

9.5219.05

6.35x4EA12.7x4EA

481

1~312,000~54,000

Paintingless1ø, 50/60Hz

220~240/220V10

0.05302x143x252422x202x300

4.94x0.754x0.75

9.5219.05

6.35x3EA9.52x3EA

481

1~212,000~54,000

Paintingless1ø, 50/60Hz

220~240/220V10

0.05302x143x252422x202x300

4.84x0.754x0.75

9.5219.05

6.35x2EA9.52x2EA

481

36

72

54

2 Indoor units 3 Indoor units 4 Indoor unitsModel

Connectable number of indoor unitsCapacity(kBtu/h)

1 2 3 4 5 6 7 8 9

P M B D 5 4 2 0 L

L : R-22None : R410ASerial number

Number of indoor units connectable

Maximum capacity

Branch distributor

Multi

Parts

• BD(Banch Distributor) unit (1EA)• Hanger metal (4EA)• Screws (8EA)• Installation Manual (1EA)

Page 30: GL-AC081forfuture.cz/SOUBORY/KATALOGY/KATALOGY_LG/LG... · PQRCUSA0 PCRCUSZ0 PZRCUSB0 PDRCUSZ0 PQRCUDS0 (White) PQRCUDSOB (Blue) PQRCUDSOS (Silver) Wired Remote Controller Simple

58

Heat Recovery UnitP I P I N G ACC E SSO RY

PRHR020 / PRHR030 / PRHR040

Pip

ing

Ac

ce

ssory

58

59

DIMENSIONDETAILS OF MODEL NAME1 2 3 4 5 6 7

P R H R 0 4 0

Serial No.

No. of Connected Rooms02 : For 2 Rooms03 : For 3 Rooms04 : For 4 Rooms

HR unitMulti VPart

59P I P I N G ACC E SSO RY

FEATURES

REDUCERS FOR INDOOR UNIT AND HR UNIT

MODELS APPLIED TO

ACCESSORY MODEL NAME AND SPECIFICATION

• Max. 4 indoor unit can be connected by module design.• Due to the automatic search algorithm for piping detection, easy installation and effectiveness is improved.• Subcooling cycle in HR unit makes the system efficiency maximum.

PRHR020(2 Indoor Units)

PRHR030(3 Indoor Units)

PRHR040(4 Indoor Units)

INSTALLATION

Outdoor unit

Indoor units

Model PRHR020 PRHR030 PRHR040Max. connectable number of indoor unitsMax. connectable capacity of indoor units(Per port/unit)Nominal Input Cooling

HeatingNet. WeightDimensions(WxHxD)Piping Indoor Liquidconnections Unit Gas

Outdoor LiquidUnit Low pressure

High PressurePower Supply

2 3 4

14.1 / 47

26 40 40

26 40 40

19 20 21

801x218x617 801x218x617 801x218x617

9.52(3/8)

15.88(5/8)

9.52(3/8) 12.7(1/2) 12.7(1/2)

19.05(3/4) 28.58(1 1/8) 28.58(1 1/8)

19.05(3/4) 22.2(7/8) 22.2(7/8)

1 / 220~240 / 50

kWkWkWkg

mmmm(inch)mm(inch)mm(inch)mm(inch)mm(inch)ø /V/Hz

EA

OD15.88 Ø12.7Ø6.35OD9.52

OD22.2 Ø19.05 Ø15.88

OD15.88 Ø12.7

Ø6.35OD9.52

OD19.05 Ø15.88 Ø12.7

OD12.7 Ø9.52

OD28.58 Ø22.22 Ø19.25

OD19.05 Ø15.88

OD12.7 Ø9.52

OD22.2 Ø19.05 Ø15.88

OD15.88 Ø12.7

Indoor unit reducer

PRHR020

HR unitreducer

PRHR030/PRHR040

Models Liquid pipe High pressure Low pressure

(Unit : mm)

• HR unit (1EA)• Hanging bolts M10 or M8 (4EA)• Nut M8 or M10 (8EA)• Flat washers M10 (8EA)• Reducers

Page 31: GL-AC081forfuture.cz/SOUBORY/KATALOGY/KATALOGY_LG/LG... · PQRCUSA0 PCRCUSZ0 PZRCUSB0 PDRCUSZ0 PQRCUDS0 (White) PQRCUDSOB (Blue) PQRCUDSOS (Silver) Wired Remote Controller Simple

60

Y Branch and Branch Kit (MULTI Fdx)

1ø, 3ø

P I P I N G ACC E SSO RY

Pip

ing

Ac

ce

ssory

60

61

61P I P I N G ACC E SSO RY

FEATURES

APPLICATION

ACCESSORY MODEL NAME

• Y Branch and Branch kit make Multi Fdx installation much easier.• Y-Branch and Branch kit for both gas and liquid are provided.• Insulation material is also provided for covering the branches.

PARTS SUPPLIED

• Y Branch for Gas side and Liquid side (1 set)• Installation manual (1EA)

MODELS APPLIED TO

Refrigerant distribution channel

PMBL3620 / PMBL5620 (2units)PMBL1203F0 (3units)

Model Name No. of BD units Applicable ModelSpecification

LiquidGas

PMBL3620

PMBL5620

PMBL1203F0

2 units

2 units

3 units

Only 3ø, 36k Btu/h

1ø, 3ø

1ø, 3ø

Ø15.88 Ø15.88

Ø15.88

Ø19.05 Ø19.05

Ø19.05

Ø9.52 Ø9.52

Ø9.52

Ø6.35 Ø6.35

Ø6.35

Y Branch and Header Branch (MULTI V)P I P I N G ACC E SSO RY

FEATURES

PIPING DIAGRAM

ACCESSORY MODEL NAME

• Various Y-branch pipe of different capacities make MULTI V installation much easier.• Y-branch and header branch for both gas and liquid are provided.• Insulation material is also provided for covering the branches.

MODELS APPLIED TO

For refrigerant distribution in multi indoor units.

Header Branch

Y Branch

• • •

Outdoor unit

Y- branch Header branch

• R22 / R410AModels

4 branch / ARBL054

7 branch / ARBL057

4 branch / ARBL104

7 branch / ARBL107

10 branch / ARBL1010

10 branch / ARBL2010

Gas pipe Liquid pipe

(Unit : mm)

(Unit : mm)

• • • •

Header Branch / Y Branch

▶ Header Branch

Page 32: GL-AC081forfuture.cz/SOUBORY/KATALOGY/KATALOGY_LG/LG... · PQRCUSA0 PCRCUSZ0 PZRCUSB0 PDRCUSZ0 PQRCUDS0 (White) PQRCUDSOB (Blue) PQRCUDSOS (Silver) Wired Remote Controller Simple

Pip

ing

Ac

ce

ssory

6 2

63

62P I P I N G ACC E SSO RY

(Unit : mm)

(Unit : mm)

▶ Y Branch Pipe for connection of outdoor units

ARBL202C

Models Gas pipe

2 Outdoor Units

Liquid pipe

• R22 /

ARNCNN20

Models Gas pipe

2 Outdoor Units

Liquid pipe

• R410A /

ARNCNN20

ARNCNN30

Models Gas pipe

3 Outdoor Units

Liquid pipe

(Unit : mm)

ARBL202C

ARBL302C

Models Gas pipe

3 Outdoor Units

Liquid pipe

ARCNB20

ModelsLow Pressure

Gas pipeGas pipe

2 Outdoor Units

High PressureGas pipe

ARCNB20

ARCNB30

ModelsLow Pressure

Gas pipeGas pipe

3 Outdoor Units

High PressureGas pipe

• R410A /

63P I P I N G ACC E SSO RY

ARBL052S

ARBL052L

ARBL102S

ARBL102L

Models Gas pipe Liquid pipe

ARBL202S

ARBL202L

ARBL302S

ARBL302L

Models Gas pipe Liquid pipe(Unit : mm)

(Unit : mm)

(Unit : mm)

(Unit : mm)

▶ Y Branch Pipe for connection of indoor units

• R22 / • R22 /

ARBLN01620

ARBLN03320

Models Gas pipe Liquid pipe

• R410 /

(Unit : mm)

ARBLN07120

ARBLN14520

Models Gas pipe Liquid pipe

• R410 /

ARBLB01620

ARBLB03320

ARBLB07120

ARBLB14520

Models Low Pressure Gas pipe Gas pipe High Pressure Gas pipe

I.D. 15.88

I.D. 15.88

I.D. 12.7

I.D. 12.7

I.D. 15.88

I.D. 12.7

I.D. 19.05

O.D. 28.58I.D. 25.4

O.D. 22.2

I.D. 22.2

I.D. 19.05

I.D. 12.7

I.D. 15.88

I.D. 9.52

I.D. 19.05

I.D. 15.88

I.D. 22.2

I.D. 15.88

O.D. 19.05I.D. 15.88

I.D. 12.7

O.D. 22.2 I.D. 15.88I.D. 19.05

I.D. 34.9 I.D. 31.8

O.D. 28.58

I.D. 28.58

I.D. 22.2I.D. 25.4

I.D. 19.05

I.D. 22.2I.D. 28.58

I.D. 25.4

X 2

I.D. 28.58

I.D. 22.2

O.D. 19.05

I.D. 15.88

I.D. 12.7

O.D. 34.9

X 2

I.D. 31.8

I.D. 19.05

I.D. 28.58

O.D. 25.4

I.D. 31.8

I.D. 28.58

I.D. 25.4

I.D. 34.9I.D. 41.3

I.D. 38.1

I.D. 22.2O.D. 28.58

I.D. 41.3I.D. 34.9

I.D. 9.52

I.D. 6.35

I.D. 9.52

I.D. 6.35

I.D. 12.7

I.D. 9.52I.D. 6.35

I.D. 9.52

I.D. 6.35

I.D. 9.52

I.D. 6.35

I.D. 12.7

I.D. 9.52I.D. 6.35

I.D. 9.52 O.D. 12.7

I.D. 15.88

I.D. 12.7

I.D. 12.7

I.D. 9.52

I.D. 6.35

I.D. 9.52

I.D. 12.7I.D. 19.05

I.D. 15.88

I.D. 15.88

O.D. 9.52I.D. 6.35

I.D. 19.05

I.D. 15.88

I.D. 12.7

I.D. 9.52

I.D. 12.7

I.D. 19.05

I.D. 15.88

I.D. 22.2

I.D. 15.88I.D. 12.7

I.D. 15.88

I.D. 12.7

I.D. 9.52

I.D. 9.52

I.D. 6.35I.D. 12.7

I.D. 22.2O.D. 19.05

I.D. 19.05I.D. 15.88

I.D. 19.05

I.D. 15.88

I.D. 9.52

I.D. 12.7

I.D. 6.35I.D. 12.7

O.D. 19.05

I.D. 12.7

I.D. 9.52

I.D. 28.58

I.D. 25.4

I.D. 15.88

I.D. 19.05

I.D. 19.05I.D. 12.7

O.D. 19.05I.D. 12.7

I.D. 19.05I.D. 28.58

I.D. 22.2

I.D. 19.05

O.D. 19.05

I.D. 12.7

I.D. 9.52O.D. 28.58I.D. 22.2

I.D. 28.58

I.D. 19.05

I.D. 28.58

I.D. 34.9

I.D. 28.58I.D. 25.4

• R410A /