Glasgow UpdateR. Bates. A. Blue, S Chambers, T. McMullen, C. Valentine & K. Wraight
Strip Sensors Meeting
Update
• Electrical Characterisation• I-V’s
– Temperature dependence– Arrhenius plots
• C-V
• CCE– Analysis s/ware – Preliminary results
Strip Sensors Meeting
Current-Voltage characteristics
Summary
• IV of all non-irradiated devices– Temperatures -45 to 20C
• IV of all irradiated devices
(except for gammas)– -20C– Some -45C to -20C
• Analysis on going
IV of all irradiated devices
Strip Sensors Meeting
Capacitance - Voltage
Set-up– 0 – 600V– ΔV : 5V, Δt : 10 s– integration time : 2 s – measurement frequencies:
10kHz, 100kHz, 1MHz– Compliance : 0.1mA– Model : C_sR_s
• Vfd = 350V• Cfd = 24pF
– (23.8,23.85,24.3pF)
Non-irradiated (3 different samples)
Strip Sensors Meeting
Charge collection update
• We had an issue with Alibava analysis for a while– Using newest version of Alibava DAQ– Data sets not being read by older analysis code (sin_preguntas and
idk-ana – from Ljubljana)– New sin-preguntas does not give much information, only pulse
height spectra– Edited idk-ana code to read new data format
• This stalled testing as alignment is done by hand in our system and we need analyzed data to feedback on this
• Second issue with HV breakdown at >700V was observed in irradiated devices– Eventually tracked down to a current path from the detector mount to
system temperature sensor. Fixed!
• In situ annealing verified without silicon sensor
Strip Sensors Meeting
Un-irradiated calibration
BZ3C_P12• System calibrated with un-
irradiated sensor (BZ3C_P12)– +20C Full_CC = 101 ADC– -20C Full_CC = 116 ADC(ignored 500V point)
– Note an issue with sensor breakdown at >550V, but fine for plateau
• Measurements of post –radiation resume 18/3/2014
Strip Sensors Meeting
Summary