14
GONIOPHOTOMETERS SYSTEM TEST REPORT Page 1 Of 14 LUMINAIRE PHOTOMETRIC TEST REPORT NAME: LED PANEL SPEC.:3060 MFR.: TYPE:Recessed DIM.: 295*595*9 SUR.:0.36 WEIGHT:1.8 SERIAL No.: PROTECTION ANGLE: Test:U:220.0V I:0.1750A P:35.90W PF:0.9330 Lamp Flux:2707.91x1 lm 0 30 60 90 120 150 -/+180 -150 -120 -90 -60 -30 UNIT:cd C0/180, 56.0,56.3 UNIT:cd C30/210, 56.0,55.9 UNIT:cd C60/240, 56.1,55.7 UNIT:cd C90/270, 56.1,55.6 AVERAGE BEAM ANGLE(50%):111.9 DEG 0 190 380 570 760 950 LUMINOUS INTENSITY DISTRIBUTION DIAGRAM C0 PLANE ISOLUX DIAGRAM (UNIT:lx) MH(m) 2 3 4 5 6 7 8 9 10 11 12 0.0 4.5 9.0 S(m) 140 120 95.0 71.0 47.0 24.0 19.0 12.0 9.50 7.10 DATA OF LAMP PHOTOMETRIC DATA Eff: 75.43 lm/W MODEL NOMINAL POWER(W) RATED VOLTAGE(V) NOMINAL FLUX(lm) LAMPS INSIDE TEST VOLTAGE(V) Imax(cd) LOR(%) TOTAL FLUX(lm) CIE CLASS up(%) down(%) S/MH(C0/180) S/MH(C90/270) UP,DN(C0-180) UP,DN(C180-360) CIBSE SHR NOM CIBSE SHR MAX SLP-36-36W-216Q41KR80 36 220 2707.91 1 230 945.8 100.0 2707.9 DIRECT 0.0 100.0 1.25 1.24 0.0,49.8 0.0,50.2 1.25 1.35 C Range: 0 - 360DEG C Interval: 5.0DEG Range: 0 - 90DEG Test Speed: HIGH Temperature:25.3DEG Operators:T01 Test Date:2014-11-21 Interval: 0.5DEG Test System: Humidity:65.0% Test Distance:9.890m [K=1.0000] Remarks: 4100K

GONIOPHOTOMETERS SYSTEM TEST REPORT …docs.elmarkholding.eu/ndocs/en/INDOR LIGHTING/LED Panels/LED Pa… · goniophotometers system test report page 2 of 14 zonal flux diagram and

Embed Size (px)

Citation preview

Page 1: GONIOPHOTOMETERS SYSTEM TEST REPORT …docs.elmarkholding.eu/ndocs/en/INDOR LIGHTING/LED Panels/LED Pa… · goniophotometers system test report page 2 of 14 zonal flux diagram and

GONIOPHOTOMETERS SYSTEM TEST REPORT

Page 1 Of 14

LUMINAIRE PHOTOMETRIC TEST REPORT

NAME: LED PANEL

SPEC.:3060

MFR.:

TYPE:Recessed

DIM.: 295*595*9

SUR.:0.36

WEIGHT:1.8

SERIAL No.:

PROTECTION ANGLE:

Test:U:220.0V I:0.1750A P:35.90W PF:0.9330 Lamp Flux:2707.91x1 lm

0

30

60

90

120

150

-/+180

-150

-120

-90

-60

-30

UNIT:cd

C0/180, 56.0,56.3

UNIT:cd

C30/210, 56.0,55.9

UNIT:cd

C60/240, 56.1,55.7

UNIT:cd

C90/270, 56.1,55.6AVERAGE BEAM ANGLE(50%):111.9 DEG

0

190

380

570

760

950

LUMINOUS INTENSITY DISTRIBUTION DIAGRAM C0 PLANE ISOLUX DIAGRAM (UNIT:lx)MH(m)2

3

4

5

6

7

8

9

10

11

120.0 4.5 9.0

S(m)140

120

95.0

71.0

47.0

24.0

19.0

12.0

9.50

7.10

DATA OF LAMP PHOTOMETRIC DATA Eff: 75.43 lm/W

MODEL

NOMINAL POWER(W)

RATED VOLTAGE(V)

NOMINAL FLUX(lm)

LAMPS INSIDE

TEST VOLTAGE(V)

Imax(cd)

LOR(%)

TOTAL FLUX(lm)

CIE CLASS

up(%)

down(%)

S/MH(C0/180)

S/MH(C90/270)

UP,DN(C0-180)

UP,DN(C180-360)

CIBSE SHR NOM

CIBSE SHR MAX

SLP-36-36W-216Q41KR80

36

220

2707.91

1

230

945.8

100.0

2707.9

DIRECT

0.0

100.0

1.25

1.24

0.0,49.8

0.0,50.2

1.25

1.35

C Range: 0 - 360DEGC Interval: 5.0DEG

Range: 0 - 90DEG

Test Speed: HIGHTemperature:25.3DEGOperators:T01Test Date:2014-11-21

Interval: 0.5DEGTest System:Humidity:65.0%Test Distance:9.890m [K=1.0000]Remarks: 4100K

Page 2: GONIOPHOTOMETERS SYSTEM TEST REPORT …docs.elmarkholding.eu/ndocs/en/INDOR LIGHTING/LED Panels/LED Pa… · goniophotometers system test report page 2 of 14 zonal flux diagram and

GONIOPHOTOMETERS SYSTEM TEST REPORT

Page 2 Of 14

ZONAL FLUX DIAGRAM

AND LUMINANCE LIMITATION CURVES

ZONAL FLUX DIAGRAM:

5 0- 510 5- 10

15 10- 1520 15- 20

25 20- 2530 25- 30

35 30- 35

40 35- 4045 40- 45

50 45- 5055 50- 55

60 55- 6065 60- 65

70 65- 7075 70- 75

80 75- 80

85 80- 8590 85- 90

95 90- 95100 95-100

105 100-105110 105-110

115 110-115120 115-120

125 120-125

130 125-130135 130-135

140 135-140145 140-145

150 145-150155 150-155

160 155-160165 160-165

170 165-170

175 170-175180 175-180

C0 C45 C90 C135 C180 C225 C270 C315 zone total %lum,lamp

DEG LUMINOUS INTENSITY:cd UNIT:lm

941.6 937.5 937.0 937.3 941.5 937.3 936.9 937.6 22.50 22.50 0.83,0.83929.6 925.5 928.2 924.3 928.9 924.6 928.0 925.7 66.67 89.17 3.29,3.29

909.1 906.8 902.0 905.2 907.8 905.8 902.4 907.6 108.6 197.8 7.3,7.3879.9 874.3 875.7 872.5 878.7 873.6 876.9 875.2 146.6 344.4 12.7,12.7

843.8 838.1 833.7 836.9 841.6 838.4 835.2 839.7 179.7 524.1 19.4,19.4799.7 793.3 791.7 791.6 797.0 793.5 793.4 795.1 206.4 730.5 27,27

748.4 740.8 736.1 738.8 745.3 740.8 739.1 743.3 226.1 956.5 35.3,35.3

690.8 685.5 680.5 683.0 687.2 685.4 684.8 688.6 237.9 1194 44.1,44.1628.1 620.4 616.1 618.5 624.2 622.0 621.0 624.3 241.8 1436 53,53

560.9 554.8 551.6 554.2 556.9 558.8 557.1 559.7 237.9 1674 61.8,61.8491.0 483.8 481.6 483.2 486.8 488.2 487.7 489.4 226.5 1901 70.2,70.2

419.3 413.6 411.6 413.1 415.0 418.3 418.3 419.6 208.4 2109 77.9,77.9346.8 340.1 340.5 341.7 342.8 347.2 347.0 346.3 184.5 2294 84.7,84.7

272.3 267.7 269.3 271.0 269.3 276.1 275.8 273.8 155.8 2449 90.5,90.5198.1 196.0 199.8 200.0 196.2 204.4 205.6 201.5 123.1 2573 95,95

126.0 123.3 130.2 129.9 124.3 133.8 135.4 128.2 87.36 2660 98.2,98.2

54.02 33.37 0 36.74 47.46 38.17 0 35.17 43.79 2704 99.8,99.81.215 0 0 0 0.6352 0 0 0 4.239 2708 100,100

LUMINANCE LIMITATION CURVES

GLARE CLASS ILLUMINANCE (lx)

1.15 A 2000 1000 500 <=300

1.50 B 2000 1000 500 <=300

1.85 C 2000 1000 500 <=300

2.20 D 2000 1000 500 <=300

2.55 E 2000 1000 500 <=300

a b c d e f g h

45

55

65

75

85G(DEG)

8 1000 2 3 4 5 6 8 10000 2 3 41

2

3

4

68

a/h

LUMINANCE (cd/(m2))

a b c d e f g h

C0/180 C90/270

LUMINANCE cd/(m2)

G(DEG) C0/180 C90/270

85 1722 0

80 2016 2083

75 2126 2144

70 2212 2187

65 2279 2238

60 2329 2287

55 2378 2332

50 2424 2384

45 2467 2420

C Range: 0 - 360DEGC Interval: 5.0DEG

Range: 0 - 90DEG

Test Speed: HIGHTemperature:25.3DEGOperators:T01Test Date:2014-11-21

Interval: 0.5DEGTest System:EHumidity:65.0%Test Distance:9.890m [K=1.0000]Remarks: 4100K

Page 3: GONIOPHOTOMETERS SYSTEM TEST REPORT …docs.elmarkholding.eu/ndocs/en/INDOR LIGHTING/LED Panels/LED Pa… · goniophotometers system test report page 2 of 14 zonal flux diagram and

GONIOPHOTOMETERS SYSTEM TEST REPORT

Page 3 Of 14

CU AND LUMINAIRE BUDGETARY ESTIMATE DIAGRAM

NAME: LED PANEL

SPEC.:3060

MFR.:

TYPE:Recessed

DIM.: 295*595*9

SUR.:0.36

WEIGHT:1.8

SERIAL No.:

PROTECTION ANGLE:

Test:U:220.0V I:0.1750A P:35.90W PF:0.9330 Lamp Flux:2707.91x1 lm

cc

w

fc

RCR Coefficients of Utilization(CU)RCR:Room Cavity Ratio

80%

50% 30% 10%

20%

70%

50% 30% 10%

20%

50%

50% 30% 10%

20%

30%

50% 30% 10%

20%

10%

50% 30% 10%

20%

0

0

0

0.0

1.0

2.0

3.0

4.0

5.0

6.0

7.0

8.0

9.0

10.0

1.19

1.04

.90

.79

.70

.62

.56

.51

.46

.43

.39

1.19

.99

.83

.71

.61

.53

.47

.42

.38

.34

.31

1.19

.95

.77

.64

.54

.47

.41

.36

.32

.29

.26

1.16

1.01

.88

.77

.69

.61

.55

.50

.46

.42

.39

1.16

.97

.82

.70

.60

.53

.47

.42

.38

.34

.31

1.16

.94

.76

.63

.54

.46

.40

.36

.32

.29

.26

1.11

.97

.85

.74

.66

.59

.53

.48

.44

.41

.38

1.11

.94

.79

.68

.59

.52

.46

.41

.37

.34

.31

1.11

.91

.75

.62

.53

.46

.40

.35

.32

.28

.26

1.06

.93

.81

.72

.64

.57

.52

.47

.43

.40

.37

1.06

.91

.77

.66

.57

.50

.45

.40

.36

.33

.30

1.06

.88

.73

.61

.52

.45

.40

.35

.31

.28

.26

1.02

.90

.78

.69

.61

.55

.50

.46

.42

.39

.36

1.02

.87

.75

.64

.56

.49

.44

.40

.36

.33

.30

1.02

.85

.71

.60

.52

.45

.39

.35

.31

.28

.26

1.00

.83

.69

.58

.49

.43

.37

.33

.29

.26

.24

AREA(m2)10 20 30 40 50 70 100 200 300 500 700 1k 2k 3k 4k 5k 7k

2

3

4

5

6

789

10

20

30

40

50LAMPS LUMINAIRE BUDGETARY DIAGRAM

45

66

H=7H=7

455

66

H=7H=7

CONDITIONS

FLUX 5000lm

FACTOR 0.70

Hdown 0.00m

Hwork 0.00m

Ework(AVE) 100lx

cc w fc

70 50 30

50 30 20

C Range: 0 - 360DEGC Interval: 5.0DEG

Range: 0 - 90DEG

Test Speed: HIGHTemperature:25.3DEGOperators:T01Test Date:2014-11-21

Interval: 0.5DEGTest System:Humidity:65.0%Test Distance:9.890m [K=1.0000]Remarks: 4100K

Page 4: GONIOPHOTOMETERS SYSTEM TEST REPORT …docs.elmarkholding.eu/ndocs/en/INDOR LIGHTING/LED Panels/LED Pa… · goniophotometers system test report page 2 of 14 zonal flux diagram and

GONIOPHOTOMETERS SYSTEM TEST REPORT

Page 4 Of 14

WEC AND CCEC

NAME: LED PANEL

SPEC.:3060

MFR.:

TYPE:Recessed

DIM.: 295*595*9

SUR.:0.36

WEIGHT:1.8

SERIAL No.:

PROTECTION ANGLE:

Test:U:220.0V I:0.1750A P:35.90W PF:0.9330 Lamp Flux:2707.91x1 lm

cc

w

fc

RCR Wall Exitance Coeffcients(WEC)RCR:Room Cavity Ratio

80%

50% 30% 10%

20%

70%

50% 30% 10%

20%

50%

50% 30% 10%

20%

30%

50% 30% 10%

20%

10%

50% 30% 10%

20%

0

0

0

0.0

1.0

2.0

3.0

4.0

5.0

6.0

7.0

8.0

9.0

10.0

.313

.295

.272

.251

.232

.215

.200

.186

.175

.164

.178

.162

.145

.130

.118

.108

.099

.091

.084

.079

.056

.050

.043

.038

.034

.031

.028

.026

.024

.022

.306

.288

.267

.246

.227

.211

.196

.183

.172

.162

.174

.159

.143

.129

.117

.107

.098

.090

.084

.078

.055

.049

.043

.038

.034

.031

.028

.026

.024

.022

.293

.277

.256

.237

.219

.204

.190

.178

.167

.157

.168

.154

.139

.126

.114

.104

.096

.089

.082

.077

.054

.048

.042

.038

.034

.030

.028

.025

.023

.022

.280

.266

.247

.228

.212

.197

.184

.172

.162

.152

.162

.149

.135

.123

.112

.102

.094

.087

.081

.076

.052

.047

.041

.037

.033

.030

.027

.025

.023

.022

.269

.256

.238

.220

.205

.190

.178

.167

.157

.148

.156

.145

.132

.120

.109

.100

.092

.086

.080

.075

.050

.046

.041

.036

.033

.030

.027

.025

.023

.021

cc

w

fc

RCR Ceiling Cavity Exitance Coefficients(CCEC)RCR:Room Cavity Ratio

80%

50% 30% 10%

20%

70%

50% 30% 10%

20%

50%

50% 30% 10%

20%

30%

50% 30% 10%

20%

10%

50% 30% 10%

20%

0

0

0

0.0

1.0

2.0

3.0

4.0

5.0

6.0

7.0

8.0

9.0

10.0

.190

.181

.173

.165

.157

.150

.143

.136

.129

.123

.117

.190

.156

.132

.114

.101

.091

.082

.075

.070

.065

.060

.190

.134

.098

.074

.058

.047

.039

.033

.029

.025

.022

.163

.154

.148

.141

.135

.129

.123

.117

.111

.106

.101

.163

.134

.114

.099

.087

.078

.071

.065

.060

.056

.052

.163

.115

.084

.064

.050

.041

.034

.029

.025

.022

.020

.111

.106

.101

.097

.093

.089

.085

.081

.077

.073

.070

.111

.092

.079

.069

.061

.055

.050

.046

.042

.039

.037

.111

.080

.059

.045

.036

.029

.024

.020

.018

.016

.014

.064

.061

.058

.056

.054

.051

.049

.047

.045

.043

.041

.064

.053

.046

.040

.036

.032

.029

.027

.025

.023

.022

.064

.046

.035

.027

.021

.017

.014

.012

.011

.009

.008

.020

.019

.019

.018

.017

.017

.016

.015

.014

.014

.013

.020

.017

.015

.013

.012

.010

.010

.009

.008

.008

.007

.020

.015

.011

.009

.007

.006

.005

.004

.003

.003

.003

C Range: 0 - 360DEGC Interval: 5.0DEG

Range: 0 - 90DEG

Test Speed: HIGHTemperature:25.3DEGOperators:T01Test Date:2014-11-21

Interval: 0.5DEGTest System:Humidity:65.0%Test Distance:9.890m [K=1.0000]Remarks: 4100K

Page 5: GONIOPHOTOMETERS SYSTEM TEST REPORT …docs.elmarkholding.eu/ndocs/en/INDOR LIGHTING/LED Panels/LED Pa… · goniophotometers system test report page 2 of 14 zonal flux diagram and

GONIOPHOTOMETERS SYSTEM TEST REPORT

Page 5 Of 14

UGR(Unified Glare Rating) Table

NAME: LED PANEL

SPEC.:3060

MFR.:

TYPE:Recessed

DIM.: 295*595*9

SUR.:0.36

WEIGHT:1.8

SERIAL No.:

PROTECTION ANGLE:

Test:U:220.0V I:0.1750A P:35.90W PF:0.9330 Lamp Flux:2707.91x1 lm

ceiling/cavity

walls

working plane

Room dimensions Viewed crosswise Viewed endwise

0.7 0.7

0.5 0.5

0.2 0.2

0.7 0.7

0.3 0.3

0.2 0.2

0.5 0.5

0.5 0.5

0.2 0.2

0.5 0.5

0.3 0.3

0.2 0.2

0.3 0.3

0.3 0.3

0.2 0.2

x = 2H y = 2H

3H

4H

6H

8H

12H

4H 2H

3H

4H

6H

8H

12H

8H 4H

6H

8H

12H

12H 4H

6H

8H

15.9 15.817.4 17.316.1 16.117.6 17.517.8 17.7

17.5 17.418.9 18.817.8 17.719.1 19.119.4 19.3

18.2 18.119.5 19.518.5 18.419.8 19.720.0 20.0

18.7 18.719.9 20.019.0 19.020.2 20.220.5 20.5

18.8 18.820.0 20.019.1 19.220.3 20.320.6 20.6

18.9 18.820.0 20.019.2 19.120.3 20.320.6 20.6

16.5 16.417.8 17.816.8 16.718.1 18.018.4 18.3

18.3 18.319.5 19.418.7 18.619.8 19.720.1 20.0

19.1 19.120.2 20.219.5 19.520.5 20.520.9 20.8

19.7 19.820.7 20.820.1 20.221.0 21.121.4 21.5

19.9 20.020.8 20.920.3 20.421.2 21.221.5 21.6

20.0 20.020.8 20.820.4 20.421.2 21.221.6 21.6

19.4 19.420.3 20.319.8 19.820.7 20.721.1 21.1

20.2 20.320.9 21.020.6 20.721.3 21.421.8 21.9

20.4 20.521.1 21.220.9 21.021.5 21.622.0 22.1

20.6 20.521.1 21.121.0 21.021.6 21.622.1 22.0

19.4 19.420.3 20.319.9 19.920.7 20.621.1 21.0

20.3 20.420.9 21.020.7 20.821.4 21.421.8 21.9

20.6 20.621.1 21.221.0 21.121.6 21.622.1 22.1

Variations with the observer position at spacings:

S = 1.0H + 0.1 / - 0.2 + 0.1 / - 0.2

1.5H + 0.1 / - 0.3 + 0.1 / - 0.3

2.0H + 0.2 / - 0.2 + 0.2 / - 0.3

CIE Pub.117 Corrected 2708 lm Total Lamp Luminous Flux.(8log(F/F0) = 3.5)

C Range: 0 - 360DEGC Interval: 5.0DEG

Range: 0 - 90DEG

Test Speed: HIGHTemperature:25.3DEGOperators:T01Test Date:2014-11-21

Interval: 0.5DEGTest System:Humidity:65.0%Test Distance:9.890m [K=1.0000]Remarks: 4100K

Page 6: GONIOPHOTOMETERS SYSTEM TEST REPORT …docs.elmarkholding.eu/ndocs/en/INDOR LIGHTING/LED Panels/LED Pa… · goniophotometers system test report page 2 of 14 zonal flux diagram and

GONIOPHOTOMETERS SYSTEM TEST REPORT

Page 6 Of 14

UTILIZATION FACTORS TABLE

NAME: LED PANEL

SPEC.:3060

MFR.:

TYPE:Recessed

DIM.: 295*595*9

SUR.:0.36

WEIGHT:1.8

SERIAL No.:

PROTECTION ANGLE:

Test:U:220.0V I:0.1750A P:35.90W PF:0.9330 Lamp Flux:2707.91x1 lm

REFLECTANCE

Ceiling

Walls

Working plane

0.8

0.7

0.2

0.8

0.5

0.2

0.8

0.3

0.2

0.7

0.7

0.2

0.7

0.5

0.2

0.7

0.3

0.2

0.5

0.7

0.2

0.5

0.5

0.2

0.5

0.3

0.2

0

0

0

ROOM INDEX UTILIZATION FACTORS(PERCENT) k(RI) x RCR = 5

k = 0.60 57 46 39 57 45 39 55 45 38 32

0.80 67 56 48 66 55 48 64 54 48 41

1.00 76 64 57 74 64 57 72 65 56 49

1.25 83 72 65 81 71 65 79 70 64 56

1.50 88 78 71 86 77 70 83 75 69 62

2.00 95 86 79 93 85 79 89 83 77 69

2.50 99 91 85 97 89 84 93 87 82 74

3.00 102 95 89 100 94 88 96 91 86 78

4.00 106 100 96 104 99 94 99 95 92 83

5.00 109 104 100 106 102 98 102 98 95 86

ROOM INDEX UF(total) Direct

According to DIN EN 13032-2 2004 SHRNOM = 1.25Suspended

C Range: 0 - 360DEGC Interval: 5.0DEG

Range: 0 - 90DEG

Test Speed: HIGHTemperature:25.3DEGOperators:T01Test Date:2014-11-21

Interval: 0.5DEGTest System:EHumidity:65.0%Test Distance:9.890m [K=1.0000]Remarks: 4100K

Page 7: GONIOPHOTOMETERS SYSTEM TEST REPORT …docs.elmarkholding.eu/ndocs/en/INDOR LIGHTING/LED Panels/LED Pa… · goniophotometers system test report page 2 of 14 zonal flux diagram and

GONIOPHOTOMETERS SYSTEM TEST REPORT

Page 7 Of 14

ISOCANDELA DIAGRAM

NAME: LED PANEL

SPEC.:3060

MFR.:

TYPE:Recessed

DIM.: 295*595*9

SUR.:0.36

WEIGHT:1.8

SERIAL No.:

PROTECTION ANGLE:

Test:U:220.0V I:0.1750A P:35.90W PF:0.9330 Lamp Flux:2707.91x1 lm

-90-90

-80

-80

-70

-70

-60

-60

-50

-50

-40

-40

-30

-30

-20

-20

-10

-10

0

0

10

10

20

20

30

30

40

40

50

50

60

60

70

70

80

80

90

90

HORIZONTAL(DEG)

VERTICAL(DEG)

Imax:945.8(H0.0,V0.0)

(At:C=0.0,Gamma=0.0)

UNIT: cd

10% 94.5820% 189.230% 283.740% 378.350% 472.960% 567.570% 662.180% 756.690% 851.2

C Range: 0 - 360DEGC Interval: 5.0DEG

Range: 0 - 90DEG

Test Speed: HIGHTemperature:25.3DEGOperators:T01Test Date:2014-11-21

Interval: 0.5DEGTest System:EHumidity:65.0%Test Distance:9.890m [K=1.0000]Remarks: 4100K

Page 8: GONIOPHOTOMETERS SYSTEM TEST REPORT …docs.elmarkholding.eu/ndocs/en/INDOR LIGHTING/LED Panels/LED Pa… · goniophotometers system test report page 2 of 14 zonal flux diagram and

GONIOPHOTOMETERS SYSTEM TEST REPORT

Page 8 Of 14

AAI CURVES

NAME: LED PANEL

SPEC.:3060

MFR.:

TYPE:Recessed

DIM.: 295*595*9

SUR.:0.36

WEIGHT:1.8

SERIAL No.:

PROTECTION ANGLE:

Test:U:220.0V I:0.1750A P:35.90W PF:0.9330 Lamp Flux:2707.91x1 lm

413.1234

403.716

13.281

26.5617

807.432

39.843

00.0000

12011.15

516.4

26.5617

16014.86

722.97

413.1234

20018.58

929.53

mft

lxfc

DEG out = 1944 lm

Eave

Note:The Curves indicate the illuminated area and the averageillumination when the luminaire is at different distance.

C Range: 0 - 360DEGC Interval: 5.0DEG

Range: 0 - 90DEG

Test Speed: HIGHTemperature:25.3DEGOperators:T01Test Date:2014-11-21

Interval: 0.5DEGTest System:Humidity:65.0%Test Distance:9.890m [K=1.0000]Remarks: 4100K

Page 9: GONIOPHOTOMETERS SYSTEM TEST REPORT …docs.elmarkholding.eu/ndocs/en/INDOR LIGHTING/LED Panels/LED Pa… · goniophotometers system test report page 2 of 14 zonal flux diagram and

GONIOPHOTOMETERS SYSTEM TEST REPORT

Page 9 Of 14

ISOLUX DIAGRAM

NAME: LED PANEL

SPEC.:3060

MFR.:

TYPE:Recessed

DIM.: 295*595*9

SUR.:0.36

WEIGHT:1.8

SERIAL No.:

PROTECTION ANGLE:

Test:U:220.0V I:0.1750A P:35.90W PF:0.9330 Lamp Flux:2707.91x1 lm

68.9' 21.01m

55.1' 16.81m

16.81m

55.1'

41.4' 12.61m

27.6' 8.40m

8.40m

27.6'

13.8' 4.20m

0.0' 0.00m

0.00m

0.0'

13.8' 4.20m

27.6' 8.40m

8.40m

27.6'

41.4' 12.61m

55.1' 16.81m

16.81m

55.1'

68.9' 21.01m

MOUNTING HEIGHT: 33'(10.0m)

3% 0.2837lx 0.02636fc

5% 0.4729lx 0.04393fc

10% 0.9458lx 0.08787fc

30% 2.837lx 0.2636fc

50% 4.729lx 0.4393fc

C Range: 0 - 360DEGC Interval: 5.0DEG

Range: 0 - 90DEG

Test Speed: HIGHTemperature:25.3DEGOperators:T01Test Date:2014-11-21

Interval: 0.5DEGTest System:EHumidity:65.0%Test Distance:9.890m [K=1.0000]Remarks: 4100K

Page 10: GONIOPHOTOMETERS SYSTEM TEST REPORT …docs.elmarkholding.eu/ndocs/en/INDOR LIGHTING/LED Panels/LED Pa… · goniophotometers system test report page 2 of 14 zonal flux diagram and

GONIOPHOTOMETERS SYSTEM TEST REPORT

Page 10 Of 14

Planar Illuminance Curve

Planar Illuminance Curve

-25 -20 -15 -10 -5 0 5 10 15 20 25

Distance(m)

0

0.95

1.9

2.85

3.8

4.75

5.7

6.65

7.6

8.55

9.5E(lx) MH = 10 m

C0/180

C90/270

C Range: 0 - 360DEGC Interval: 5.0DEG

Range: 0 - 90DEG

Test Speed: HIGHTemperature:25.3DEGOperators:T01Test Date:2014-11-21

Interval: 0.5DEGTest System:Humidity:65.0%Test Distance:9.890m [K=1.0000]Remarks: 4100K

Page 11: GONIOPHOTOMETERS SYSTEM TEST REPORT …docs.elmarkholding.eu/ndocs/en/INDOR LIGHTING/LED Panels/LED Pa… · goniophotometers system test report page 2 of 14 zonal flux diagram and

GONIOPHOTOMETERS SYSTEM TEST REPORT

Page 11 Of 14

LUMINOUS DISTRIBUTION INTENSITY DATA

NAME: LED PANEL

SPEC.:3060

MFR.:

TYPE:Recessed

DIM.: 295*595*9

SUR.:0.36

WEIGHT:1.8

SERIAL No.:

PROTECTION ANGLE:

Test:U:220.0V I:0.1750A P:35.90W PF:0.9330 Lamp Flux:2707.91x1 lm

(DEG)

C(DEG)

Table--1 UNIT: cd

0

0 946

5 942

10 930

15 909

20 880

25 844

30 800

35 748

40 691

45 628

50 561

55 491

60 419

65 347

70 272

75 198

80 126

85 54.0

90 1.21

5

946

941

928

907

878

841

797

746

688

626

559

490

420

348

272

197

119

34.3

0.00

10

946

940

927

906

876

840

796

746

690

629

560

489

417

345

271

196

109

34.5

0.00

15

946

940

926

905

876

840

798

748

689

625

558

489

416

345

270

194

111

36.6

0.00

20

946

939

926

905

877

842

798

744

687

625

557

488

417

342

268

195

116

41.1

0.00

25

946

939

925

905

878

842

795

743

688

624

557

489

415

342

270

194

119

45.4

0.00

30

946

938

925

906

879

839

794

745

686

623

558

486

414

342

268

194

121

48.0

0.00

35

946

938

925

907

877

838

795

743

685

625

555

486

413

342

268

194

122

44.2

0.00

40

946

938

925

908

875

838

796

741

685

622

554

485

413

341

268

195

122

39.1

0.00

45

946

938

926

907

874

838

793

741

686

620

555

484

414

340

268

196

123

33.4

0.00

50

946

937

926

905

874

839

792

742

683

620

553

484

412

340

268

197

124

27.5

0.00

55

946

937

926

904

874

838

791

743

682

620

552

484

412

340

268

197

125

21.8

0.00

60

946

937

927

903

874

837

791

741

681

619

552

484

412

340

268

197

127

16.5

0.00

65

946

937

927

903

874

836

791

739

681

618

552

483

411

340

269

198

128

11.8

0.00

70

946

937

928

902

874

835

791

738

680

617

552

482

411

340

269

199

129

7.67

0.00

75

946

937

928

902

875

834

791

737

680

617

552

482

411

340

269

199

129

4.36

0.00

80

946

937

928

902

875

834

792

737

681

617

552

482

411

340

269

199

130

1.96

0.00

85

946

937

928

902

875

834

792

736

681

616

552

482

411

340

269

199

130

0.49

0.00

90

946

937

928

902

876

834

792

736

681

616

552

482

412

340

269

200

130

0.00

0.00

C Range: 0 - 360DEGC Interval: 5.0DEG

Range: 0 - 90DEG

Test Speed: HIGHTemperature:25.3DEGOperators:T01Test Date:2014-11-21

Interval: 0.5DEGTest System:Humidity:65.0%Test Distance:9.890m [K=1.0000]Remarks: 4100K

Page 12: GONIOPHOTOMETERS SYSTEM TEST REPORT …docs.elmarkholding.eu/ndocs/en/INDOR LIGHTING/LED Panels/LED Pa… · goniophotometers system test report page 2 of 14 zonal flux diagram and

GONIOPHOTOMETERS SYSTEM TEST REPORT

Page 12 Of 14

LUMINOUS DISTRIBUTION INTENSITY DATA

NAME: LED PANEL

SPEC.:3060

MFR.:

TYPE:Recessed

DIM.: 295*595*9

SUR.:0.36

WEIGHT:1.8

SERIAL No.:

PROTECTION ANGLE:

Test:U:220.0V I:0.1750A P:35.90W PF:0.9330 Lamp Flux:2707.91x1 lm

(DEG)

C(DEG)

Table--2 UNIT: cd

95

0 946

5 937

10 928

15 902

20 875

25 834

30 791

35 736

40 681

45 616

50 551

55 482

60 412

65 341

70 270

75 200

80 131

85 0.49

90 0.00

100

946

937

928

902

875

834

791

736

680

616

551

482

412

341

270

200

131

1.98

0.00

105

946

937

927

902

875

834

791

736

680

616

551

482

412

341

270

201

131

4.44

0.00

110

946

937

927

902

874

834

790

737

680

617

551

482

412

341

270

201

131

7.86

0.00

115

946

937

926

902

873

835

790

738

680

618

551

483

412

341

270

201

131

12.2

0.00

120

946

937

926

902

873

836

789

739

680

619

551

483

412

342

271

200

131

17.3

0.00

125

946

937

925

903

872

837

789

741

680

619

552

483

412

342

271

200

131

23.1

0.00

130

946

937

925

904

872

838

790

739

681

619

552

483

413

342

271

200

130

29.7

0.00

135

946

937

924

905

873

837

792

739

683

618

554

483

413

342

271

200

130

36.7

0.00

140

946

937

924

906

873

836

794

739

682

619

553

484

413

342

271

200

129

43.9

0.00

145

946

938

924

905

875

836

793

741

682

621

553

485

413

342

271

199

128

51.1

0.00

150

946

938

924

904

877

836

791

743

683

619

554

484

414

341

269

197

126

57.6

0.00

155

946

938

924

903

876

838

792

741

685

621

553

484

413

342

269

195

122

54.5

0.00

160

946

939

925

903

874

839

794

740

683

622

554

484

413

341

269

190

115

48.2

0.00

165

946

939

925

903

874

837

794

743

683

620

554

486

412

341

267

185

104

41.2

0.00

170

946

940

926

904

874

837

792

741

684

623

554

484

413

342

267

185

95.4

35.7

0.00

175

946

941

927

906

876

838

794

742

684

621

554

484

412

340

267

195

96.1

30.9

0.00

180

946

942

929

908

879

842

797

745

687

624

557

487

415

343

269

196

124

47.5

0.64

185

946

941

927

906

876

839

794

742

684

621

554

484

413

341

267

196

124

55.1

0.00

C Range: 0 - 360DEGC Interval: 5.0DEG

Range: 0 - 90DEG

Test Speed: HIGHTemperature:25.3DEGOperators:T01Test Date:2014-11-21

Interval: 0.5DEGTest System:Humidity:65.0%Test Distance:9.890m [K=1.0000]Remarks: 4100K

Page 13: GONIOPHOTOMETERS SYSTEM TEST REPORT …docs.elmarkholding.eu/ndocs/en/INDOR LIGHTING/LED Panels/LED Pa… · goniophotometers system test report page 2 of 14 zonal flux diagram and

GONIOPHOTOMETERS SYSTEM TEST REPORT

Page 13 Of 14

LUMINOUS DISTRIBUTION INTENSITY DATA

NAME: LED PANEL

SPEC.:3060

MFR.:

TYPE:Recessed

DIM.: 295*595*9

SUR.:0.36

WEIGHT:1.8

SERIAL No.:

PROTECTION ANGLE:

Test:U:220.0V I:0.1750A P:35.90W PF:0.9330 Lamp Flux:2707.91x1 lm

(DEG)

C(DEG)

Table--3 UNIT: cd

190

0 946

5 940

10 926

15 904

20 875

25 837

30 793

35 742

40 685

45 623

50 555

55 485

60 414

65 344

70 269

75 196

80 127

85 57.7

90 0.00

195

946

939

925

903

874

838

794

744

684

621

556

488

414

342

270

199

128

58.4

0.00

200

946

939

925

903

875

839

795

742

684

624

557

486

415

344

272

200

130

59.6

0.00

205

946

938

924

903

876

839

793

742

687

623

556

487

416

345

273

202

131

61.1

0.00

210

946

938

924

904

877

837

793

744

685

622

557

487

418

345

274

203

131

61.6

0.00

215

946

938

924

905

875

837

794

743

684

624

556

489

417

346

275

203

132

53.8

0.00

220

946

937

924

907

874

837

796

741

685

622

557

489

418

347

276

204

133

45.9

0.00

225

946

937

925

906

874

838

793

741

685

622

559

488

418

347

276

204

134

38.2

0.00

230

946

937

925

905

873

840

792

741

684

623

557

488

418

348

276

205

134

30.8

0.00

235

946

937

926

904

874

839

791

742

683

624

557

489

418

348

276

205

135

24.1

0.00

240

946

937

926

903

874

837

791

741

683

623

556

489

418

348

276

206

135

17.9

0.00

245

946

937

926

903

875

836

792

740

683

622

556

488

418

348

276

206

136

12.6

0.00

250

946

937

927

903

875

836

792

740

684

622

556

488

418

348

276

206

136

8.16

0.00

255

946

937

927

902

876

835

793

739

684

621

556

488

418

347

276

206

136

4.61

0.00

260

946

937

928

902

876

835

793

739

685

621

557

488

418

347

276

206

136

2.06

0.00

265

946

937

928

902

877

835

793

739

685

621

557

488

418

347

276

206

136

0.51

0.00

270

946

937

928

902

877

835

793

739

685

621

557

488

418

347

276

206

135

0.00

0.00

275

946

937

928

903

877

835

794

739

685

621

557

488

418

347

276

205

135

0.51

0.00

280

946

937

928

903

877

836

794

740

685

621

557

488

418

347

276

205

135

2.04

0.00

C Range: 0 - 360DEGC Interval: 5.0DEG

Range: 0 - 90DEG

Test Speed: HIGHTemperature:25.3DEGOperators:T01Test Date:2014-11-21

Interval: 0.5DEGTest System:Humidity:65.0%Test Distance:9.890m [K=1.0000]Remarks: 4100K

Page 14: GONIOPHOTOMETERS SYSTEM TEST REPORT …docs.elmarkholding.eu/ndocs/en/INDOR LIGHTING/LED Panels/LED Pa… · goniophotometers system test report page 2 of 14 zonal flux diagram and

GONIOPHOTOMETERS SYSTEM TEST REPORT

Page 14 Of 14

LUMINOUS DISTRIBUTION INTENSITY DATA

NAME: LED PANEL

SPEC.:3060

MFR.:

TYPE:Recessed

DIM.: 295*595*9

SUR.:0.36

WEIGHT:1.8

SERIAL No.:

PROTECTION ANGLE:

Test:U:220.0V I:0.1750A P:35.90W PF:0.9330 Lamp Flux:2707.91x1 lm

(DEG)

C(DEG)

Table--4 UNIT: cd

285

0 946

5 937

10 928

15 903

20 876

25 836

30 793

35 740

40 685

45 622

50 557

55 488

60 418

65 347

70 275

75 205

80 134

85 4.55

90 0.00

290

946

937

928

903

876

836

793

741

684

622

557

488

418

347

275

204

134

8.01

0.00

295

946

937

927

903

875

837

793

742

684

623

557

489

418

347

275

204

133

12.3

0.00

300

946

937

927

904

875

838

793

743

685

624

557

490

418

347

275

203

132

17.3

0.00

305

946

937

926

905

875

840

793

745

685

624

557

490

418

346

275

203

130

22.9

0.00

310

946

937

926

906

875

841

794

744

686

624

558

489

419

346

274

203

129

28.9

0.00

315

946

938

926

908

875

840

795

743

689

624

560

489

420

346

274

202

128

35.2

0.00

320

946

938

925

909

876

839

797

744

688

626

559

490

419

347

274

201

127

41.4

0.00

325

946

938

925

907

878

839

796

745

687

628

559

491

419

348

273

200

126

47.2

0.00

330

946

938

925

906

880

840

796

747

688

626

562

490

419

347

274

199

126

52.2

0.00

335

946

939

925

905

879

842

796

745

690

626

560

492

419

347

274

199

125

51.8

0.00

340

946

939

926

905

877

843

799

746

688

627

560

491

421

347

273

199

125

51.5

0.00

345

946

940

926

905

876

841

799

749

690

627

560

492

419

349

273

198

125

51.5

0.00

350

946

940

927

906

877

840

797

746

690

630

561

491

419

347

273

199

125

51.7

0.00

355

946

941

928

907

878

841

797

746

688

626

560

491

421

349

273

198

126

53.3

0.00

C Range: 0 - 360DEGC Interval: 5.0DEG

Range: 0 - 90DEG

Test Speed: HIGHTemperature:25.3DEGOperators:T01Test Date:2014-11-21

Interval: 0.5DEGTest System:Humidity:65.0%Test Distance:9.890m [K=1.0000]Remarks: 4100K