Second Floor Level 62950 Roof Level 2 66550 Second Floor Level 62950 Roof Level 2 66550 1006 Second Floor Level 62950 Roof Level 2 66550 Second Floor Level 62950 Roof Level 2 66550 Soap dispenser Hand creme dispenser Optional scrub solution dispenser Paper towel dispenser Glove & Apron Dispenser Examination couch Thermally broken aluminium window Parabolic coffer lighting 600x600, grid system Medicine cabinet Service shaft with clinic sink, piping shown how water and foul waste is being treated Tissue dispenser Hospital bed Notice board Fire door GP Desk with compatible omputer PC 80mm Isover Apr 1200 Skirting board to circulaiton area White deal POA Linolium floor finish R9 slip resistant Gyproc sealent Gyproc floor channel PVC Plaster stop bead 2x13mm Gypsum plasterboard giving 90minute fire rating Continues Gyproc fire stop Cove former Sub floor to have a moisturelevel not exceeding 75% RM In accordance with BS8203 Gypsum fixing strap Scale LECTURER Drawn by Date Project number Institute of Technology Carlow BSc. in Architectural Technology Year 3 2015-2016 As indicated 23/04/2016 09:47:48 GP Room Project Number 3 Carlow Primary Health Care Centre 22/04/2016 Xhevdet Haliti Dan O Sullivan, Noel Dunne, Mark Duffy A131 1 : 20 GP Room 1 1 : 50 Elevation D - GP Room 2 1 : 50 Elevation C - GP Room 3 1 : 50 Elevation B - GP Room 4 1 : 50 Elevation A - GP Room 5 3D GP Room 6 Elevation A - GP Room 7 Elevation B - GP Room 8 Elevation C - GP Room 9 ElevationD - GP Room 10 1 : 5 Partition GP room 11

GP Room Layout

Embed Size (px)

Citation preview

Page 1: GP Room Layout

Second Floor Level62950

Roof Level 266550

Second Floor Level62950

Roof Level 266550

1006

Second Floor Level62950

Roof Level 266550

Second Floor Level62950

Roof Level 266550

Soap dispenserHand creme dispenserOptional scrub solution dispenser

Paper towel dispenserGlove & Apron Dispenser

Examination couch

Thermally broken aluminium window

Parabolic coffer lighting600x600, grid system

Medicine cabinet

Service shaft with clinic sink,piping shown how water and foulwaste is being treated

Tissue dispenser

Hospital bed

Notice boardFire doorGP Desk withcompatible omputerPC

80mm Isover Apr 1200

Skirting board to circulaitonarea

White deal POA

Linolium floor finish R9 slip resistant

Gyproc sealentGyproc floor channel

PVC Plaster stop bead

2x13mm Gypsum plasterboardgiving 90minute fire rating

Continues Gyproc fire stop

Cove former

Sub floor to have a moisturelevel not exceeding 75% RM Inaccordancewith BS8203

Gypsum fixing strap

Scale

LECTURER

Drawn by

Date

Project number

Institute of Technology CarlowBSc. in Architectural Technology

Year 3 2015-2016

As indicated

23/0

4/20

16 0

9:47

:48

GP Room

Project Number 3

Carlow Primary Health Care Centre

22/04/2016

Xhevdet Haliti

Dan O Sullivan, Noel Dunne,Mark Duffy

A131

1 : 20GP Room1

1 : 50Elevation D - GP Room2

1 : 50Elevation C - GP Room3 1 : 50

Elevation B - GP Room4 1 : 50Elevation A - GP Room5

3D GP Room6

Elevation A - GP Room7 Elevation B - GP Room8 Elevation C - GP Room9 ElevationD - GP Room10

1 : 5Partition GP room11