140
GRUNDFOS DATA BOOKLET Sanitary pumps Centrifugal pumps 50 Hz

GRUNDFOS DATA BOOKLET - Unopomp7 Euro-HYGIA® Sanitary pumps Materials Design variations See page 27. Mechanical shaft seal Grundfos offers these seal arrangements: • single seal

  • Upload
    others

  • View
    1

  • Download
    0

Embed Size (px)

Citation preview

Page 1: GRUNDFOS DATA BOOKLET - Unopomp7 Euro-HYGIA® Sanitary pumps Materials Design variations See page 27. Mechanical shaft seal Grundfos offers these seal arrangements: • single seal

GRUNDFOS DATA BOOKLET

Sanitary pumps

Centrifugal pumps50 Hz

Page 2: GRUNDFOS DATA BOOKLET - Unopomp7 Euro-HYGIA® Sanitary pumps Materials Design variations See page 27. Mechanical shaft seal Grundfos offers these seal arrangements: • single seal

2

Contents

IntroductionGrundfos sanitary pumps 3Hygienic design 3

Performance rangePerformance range, 2-pole 4Performance range, 4-pole 4

Euro-HYGIA®Euro-HYGIA® 6

F&B-HYGIA®F&B-HYGIA® 8

ContraContra 10

durietta 0durietta 0 12

SIPLASIPLA 14

MAXA and MAXANAMAXA and MAXANA 16

IdentificationType keys 18

Product dataProduct range 19

ConstructionMotor 20Motor ranges 20Motor protection 22Impeller types 23Surface treatment 23

Shaft sealsMechanical shaft seal 24

CertificationApprovals and certificates 25Certificates 25Surface finish of hygienic pumps 26

Designs and versionsDesign variations 27Version key 30

Pipe connectionsEuro-HYGIA® I 31Euro-HYGIA® II 32F&B-HYGIA® I 33F&B-HYGIA® II 33Contra I 34Contra II 37durietta 0 40MAXA 43MAXANA 44

InstallationMechanical installation 45Space requirements 45Elimination of noise and vibration 46Terminal box positions 46

Curve chartsHow to read the curve charts 48Curve conditions 49

Performance curves/Technical dataEuro-HYGIA® I 50Euro-HYGIA® II 56F&B-HYGIA® I 66F&B-HYGIA® II 72Contra I 80Contra II 88durietta 0 96SIPLA 100MAXA 80-160/XXX 106MAXANA 32-160/XXX 120

Further product documentationWebCAPS 136

Page 3: GRUNDFOS DATA BOOKLET - Unopomp7 Euro-HYGIA® Sanitary pumps Materials Design variations See page 27. Mechanical shaft seal Grundfos offers these seal arrangements: • single seal

3

Sanitary pumpsIntroduction

Grundfos sanitary pumpsStainless steel sanitary pumps designed for a wide range of hygienic and sanitary applications such as:

• food and beverage• life science• personal care• water treatment.

The Grundfos range of sanitary pumps comprises the below pump types - each state-of-the-art within its spe-cific field of application.

The pumps can be fitted with a variety of features to adapt to specific pumping tasks. In addition, it is possible to customise the pumps for optimum function or performance in relation to the job at hand.

Euro-HYGIA® Single-stage, end-suction centrifugal pumps in a variety of flexible versions. The pumps offer heads up to 70 metres, flow rates up to 108 m3/h and operating pressures up to 16 bar. Pipe connections range from DN 25 to DN 125 and motor sizes from 0.55 to 22 kW. See page 6.

F&B-HYGIA®

Single-stage, end-suction centrifugal pumps. The pumps offer heads up to 70 metres, flow rates up to 105 m3/h and operating pressures up to 16 bar. Pipe connections range from DN 40 to DN 100 and motor sizes from 1.1 to 18.5 kW. See page 8.

ContraSingle-stage or multistage, end-suction centrifugal pumps in a variety of flexible versions. The pumps offer heads up to 160 metres, flow rates up to 55 m3/h and operating pressures up to 25 bar. Pipe connections range from DN 25 to DN 80 and motor sizes from 0.55 to 18.5 kW. See page 10.

durietta 0Single-stage or multistage centrifugal pumps offering low flow and high head. The pumps are available in a vertical and a horizontal version. The pumps offer heads up to 70 metres, flow rates up to 6 m3/h and operating pressures up to 10 bar. Pipe connections range from DN 25 to DN 40 (1" to 1½") and motor sizes from 0.25 to 2.2 kW. See page 12.

SIPLASingle-stage, self-priming side-channel pumps. The pumps offer heads up to 56 metres, flow rates up to 80 m3/h and operating pressures up to 10 bar. Pipe connections range from DN 32 to DN 80 and motor sizes from 0.55 to 22 kW. See page 14.

MAXA and MAXANASingle-stage, end-suction centrifugal pumps. The MAXA pumps are designed according to DIN EN 733. The pumps offer heads up to 97 metres, flow rates up to 820 m3/h and operating pressures up to 10 bar. Pipe connections range from DN 32 to DN 150 and motor sizes from 2.2 to 90 kW. See page 16.

Hygienic designThe Grundfos sanitary pumps have been designed in accordance with the strictest hygienic design criteria.

The surface finish of the materials used is of paramount importance to prevent possible breeding grounds for bacteria and germs.

Fully drainable models are available, and the use of AISI 316L (DIN EN 1.4404/1.4435) cold-rolled and/or forged stainless steel ensures a homogeneous, pore-free surface in contrast to cast materials.

The design, materials and material surface finish are subject to a variety of national and international rules and regulations, guidelines and laws. Among these are the EU Machinery Directive, the GMP (Good Manu-facturing Practices) rules and regulations, the FDA (Food and Drug Administration) regulations, the 3A Sanitary Standards, the EU foodstuff hygienic guidelines, the DIN EN 12462 Biotechnology Standard as well as the EHEDG (European Hygienic Engineering & Design Group) and the QHD (Qualified Hygienic Design) criteria.

Shaft sealsSingle or double mechanical shaft seal arrangements are available, depending on the application and the pumped liquid. The seals offer trouble-free operation.

The single shaft seals are inboard mechanical seals with the optimum position in the pumped liquid in order to ensure lubrication, cooling as well as CIP (Cleaning In Place) and SIP (Sterilisation In Place).

Double seals are available as a tandem arrangement or mounted back-to-back.

ConnectionsA variety of connections are available, such as sterile threads to DIN 11864-1 PN 16 and sterile flanges to DIN 11864-2 PN 16. See page 31.

Page 4: GRUNDFOS DATA BOOKLET - Unopomp7 Euro-HYGIA® Sanitary pumps Materials Design variations See page 27. Mechanical shaft seal Grundfos offers these seal arrangements: • single seal

Sanitary pumps

4

Performance range

Performance range, 2-pole

Performance range, 4-pole

*durietta 0: The performance range is shown on page 96.

TM02

973

9 37

04

5 6 8 10 15 20 30 40 50 60 80 100 150 200 300 400Q [m³/h]

20

30

40

50

60

70

80

100

150

[m]H

2 3 4 5 6 7 8 9 1010 20 30 40 50 60 70 Q [l/s]

200

300

400

500

600

700

800

900

10001000

[kPa]p

50 Hz

F&B-HYGIA II

Contra ll

Euro-HYGIA I

Contra I Euro-HYGIA II MAXANA MAXA

F&B- HYGIA

Euro-HYGIA II

*durietta 0

TM02

974

0 37

04

5 6 8 10 15 20 30 40 50 60 80 100 150 200 300 400 500600 800 1000Q [m³/h]

5

10

15

20

30

40

50

[m]H

2 3 4 5 6 7 8 9 1010 20 30 40 50 60 70 80 100100 Q [l/s]

50

100100

200

300

400

500

[kPa]p

50 Hz

Euro-HYGIA I

Euro-HYGIA II

SIPLA

MAXA

MAXANA

F&B-HYGIA II

F&B-HYGIA I

*durietta 0

Page 5: GRUNDFOS DATA BOOKLET - Unopomp7 Euro-HYGIA® Sanitary pumps Materials Design variations See page 27. Mechanical shaft seal Grundfos offers these seal arrangements: • single seal

5

Page 6: GRUNDFOS DATA BOOKLET - Unopomp7 Euro-HYGIA® Sanitary pumps Materials Design variations See page 27. Mechanical shaft seal Grundfos offers these seal arrangements: • single seal

6

Sanitary pumpsEuro-HYGIA®

Euro-HYGIA®

Fig. 1 Euro-HYGIA®

Technical data

Euro-HYGIA® I and II

ApplicationsThe unique hygienic design and the materials used make the Euro-HYGIA® pump range suitable for:

Life science/pharmaceutical• pure water systems (WFI)• biotechnology• infusion• nutrient and alcohol infusions• filling/bottling systems.

Personal care• pure water• lotions• perfumes.

Food and beverage• beer/breweries• dairies• soft drink mixing• yeast processes.

Other industries• cleaning solutions (CIP systems)• water treatment• semi-conductor rinsing• metal surface treatment.

ConstructionEuro-HYGIA® pumps are single-stage, end-suction centrifugal pumps, designed to meet the hygienic requirements of sterile process technology.

The pumps are available in a variety of flexible ver-sions. The pumps are CIP and SIP capable in compli-ance with the DIN EN 12462 performance criteria.

The design of the wetted parts complies with:

• QHD criteria• EHEDG recommendations for CIP cleanability (vali-

dated by the TNO Quality of Life institute)• 3A Sanitary Standards (US)• GOST sanitary standard (Russia).

Fig. 2 Certification

Requirements complied with:

Standard pump version:3A1Optional: 3A2, 3A3.

For explanation, see Certification, page 25.

The pump housing is made of heavy-duty, rolled and deep-drawn CrNiMo steel to DIN EN 1.4404/1.4435, the equivalent of AISI 316L.

Three impeller types are available, depending on the applications: Semi-open, closed and free-flow impeller. See page 23.

The pumps have a mechanical shaft seal and a fan-cooled asynchronous motor with enclosure to IP 55.

Fig. 3 Sectional drawing of Euro-HYGIA® I Bloc-SUPER on combi foot

GR

8963

Head: up to 70 mFlow rate: up to 108 m3/h(Euro-HYGIA® III - on request):

up to 250 m3/h

Operating pressure: up to 16 barOperating temperature: 95°C

(up to 150°C on request)Sterilisation temperature: 140°C (SIP)

TM02

960

7 35

04

1 4 5 6

2 3 7

Page 7: GRUNDFOS DATA BOOKLET - Unopomp7 Euro-HYGIA® Sanitary pumps Materials Design variations See page 27. Mechanical shaft seal Grundfos offers these seal arrangements: • single seal

Euro-HYGIA® Sanitary pumps

Materials

Design variations

See page 27.

Mechanical shaft sealGrundfos offers these seal arrangements:

• single seal• double tandem seal• double back-to-back seal.As standard, the Euro-HYGIA® is fitted with a single, inboard, mechanical shaft seal with an optimum posi-tion in the pumped liquid. This ensures lubrication, cooling as well as CIP and SIP, according to the criteria of hygienic design.

Standard seals have carbon/stainless steel seal faces and EPDM O-rings. Other seal face material combina-tions are available on request.

See page 24.

Surface treatmentAs standard, all wetted parts are electro-polished to improve corrosion-resistance and surface finish.

ConnectionsDepending on the nominal diameter of the Euro-HYGIA® pump, Grundfos offers these pipe connections as standard:

• threads to DIN 11851, PN 25-40• flanges to DIN EN 1092-1, PN 10

(DIN 2633/42, PN 10)(industrial applications only)

• pipe threads to DIN ISO 228, PN 10 (max.)• sterile threads to DIN 11864-1, PN 16• sterile flanges to DIN 11864-2, PN 16.Other connections are available on request, such as SMS, RJT, clamp connections to DIN and ISO, Tri-Clover® connections as well as special sterile threaded fittings and flanges.

See pages 31 to 32.

Features and benefits• A wide range of support options for motor and pump• Extremely reliable operation under most working

conditions• Optimised hydraulics for high efficiency

- reduced power consumption• Multi-function inducer for NPSH reduction or pump-

ing of liquids containing gas (Euro-HYGIA® II)• Motors for special voltages and frequencies• Euro-HYGIA® Adapta® and Euro-HYGIA® CN with

explosion-proof or flameproof three-phase motors available for ATEX applications

• Motors for variable speed drive with built-in fre-quency converter as "tronic", available for motor sizes up to 7.5 kW

• Mobile pumps mounted on two-wheel stainless steel trolley with on/off switch and electric cable

• DN 15 diaphragm valve drain for sterile processes• DN 15 drain connection• Heating jacket for pump housing• Integral flange ring for bolted housing closure

(HPM)• Special paint finish for the drive and the cast iron/

steel parts.

Pos. Component Material DIN EN

1 Impeller CrNiMo steel 1.4404/1.4435

2 Pump housing CrNiMo steel 1.4404/1.4435

3 Shaft sealSterile applications: SiC/SiC/EPDM Hygienic applications: Carbon/stainless steel/EPDM or FKM

4 Pump shaft CrNiMo steel 1.45715 Motor6 Shroud Stainless steel7 Support Stainless steel/cast iron

Standard variation Description

Euro-HYGIA® Adapta® Horizontal installation, Adapta® motor stool

Euro-HYGIA® Adapta® SUPERHorizontal installation, Adapta® motor stool, motor with stainless steel shroud

Euro-HYGIA® Bloc Horizontal installation

Euro-HYGIA® Bloc-SUPER Horizontal installation, motor with stainless steel shroud

Variation on request Description

Euro-HYGIA® Adapta®-V Vertical installation, Adapta® motor stool

Euro-HYGIA® Bloc-V Vertical installationEuro-HYGIA® VE Vertical tank installation

Euro-HYGIA® CN Horizontal installation, long-coupled version mounted on base plate

Euro-HYGIA® tronicHorizontal/vertical installation, motor with built-in frequency converter (up to 7.5 kW)

7

Page 8: GRUNDFOS DATA BOOKLET - Unopomp7 Euro-HYGIA® Sanitary pumps Materials Design variations See page 27. Mechanical shaft seal Grundfos offers these seal arrangements: • single seal

8

Sanitary pumpsF&B-HYGIA®

F&B-HYGIA®

Fig. 4 F&B-HYGIA®

Technical data

F&B-HYGIA® I and IIHead: up to 70 m

Flow rate: up to 105 m3/h

Operating pressure: up to 16 bar

Operating temperature: 95°C(up to 150°C on request)

Sterilisation temperature: 140°C (SIP)(Sterilisation In Place)

ApplicationsThe unique hygienic design and the materials used make the F&B-HYGIA® pump range suitable for:

BeveragesBeer, soft drinks, alcohol, wine, fruit drinks, yeast, etc.

DairiesMilk, whey, cream, condensed milk, etc.

ConfectionarySyrup, sugar solutions, etc.

Meat packingLiquid fat, frying oil, smokehouse spray, blood processing, etc.

ConstructionF&B-HYGIA® pumps are single-stage, end-suction centrifugal pumps, designed to meet the hygienic requirements of sterile process technology.

The pumps are CIP and SIP capable in compliance with the DIN EN 12462 performance criteria.

The design of the wetted parts complies with:

• QHD criteria• 3A Sanitary Standards (3A1).For explanation, see Certification, page 25.

Fig. 5 Certification

The pump housing is made of heavy-duty, rolled and deep-drawn CrNiMo steel to DIN EN 1.4404, the equiv-alent of AISI 316L.

F&B-HYGIA® pumps are fitted with a semi-open impel-ler. See page 23.

The pumps have a mechanical shaft seal (optionally with quench) and a fan-cooled, asynchronous motor with enclosure to IP 55.

Grundfos MG motors, model C, are fitted up to 11 kW, 2-pole, and 5.5 kW, 4-pole

Fig. 6 Sectional drawing of F&B-HYGIA® K on combi foot

Materials

GrA

2396

TM03

389

8 11

06

Pos. Component Material DIN EN1 Impeller CrNiMo steel 1.44042 Pump housing CrNiMo steel 1.4404

3 Shaft sealHygienic applications: Carbon/stainless steel/EPDM or FKM

4 Pump shaft CrNiMo steel 1.45715 Motor6 Support Stainless steel/cast iron

2

1 5

4 3 6

Page 9: GRUNDFOS DATA BOOKLET - Unopomp7 Euro-HYGIA® Sanitary pumps Materials Design variations See page 27. Mechanical shaft seal Grundfos offers these seal arrangements: • single seal

F&B-HYGIA® Sanitary pumps

Design variations

See page 27.

Mechanical shaft sealGrundfos offers these seal arrangements:

• single seal• quench.As standard, the F&B-HYGIA® is fitted with a single, inboard, mechanical shaft seal with an optimum posi-tion in the pumped liquid. This ensures lubrication, cooling as well as CIP and SIP, according to the criteria of hygienic design.

Carbon/stainless steel seal faces and EPDM O-rings are standard. Other seal face material combinations are available on request.

See page 24.

Surface treatmentAll chrome steel parts are blasted as standard.

ConnectionsDepending on the nominal diameter of the F&B-HYGIA® pump, Grundfos offers these pipe connections as standard:

• threads to DIN 11851, PN 25-40• clamps for Tri-Clamp®/Tri-Clover®

• flanges to DIN EN 1092-1, PN 10(DIN 2633/42, PN 10)(industrial applications only).

See pages 33 to 33.

Features and benefits• A wide range of support options for motor and

pump.• Extremely reliable operation under most working

conditions.• Optimised hydraulics for high efficiency

- reduced power consumption.• Motors for special voltages and frequencies on re-

quest.• Mobile pumps mounted on two-wheel stainless steel

trolley with on/off switch and electric cable.

Standard variation Description

F&B-HYGIA® K Horizontal installation with plug in shaft and multi-functional lantern.

F&B-HYGIA® K-SUPERHorizontal installation with plug in shaft and multi-functional lantern, motor with stainless steel shroud.

Variation on request DescriptionNone

9

Page 10: GRUNDFOS DATA BOOKLET - Unopomp7 Euro-HYGIA® Sanitary pumps Materials Design variations See page 27. Mechanical shaft seal Grundfos offers these seal arrangements: • single seal

10

Sanitary pumpsContra

Contra

Fig. 7 Contra

Technical data

Contra I and II

ApplicationsThe unique hygienic design and the materials used make the Contra pump range suitable for pressure boosting in:

Food and beverage• breweries and dairies• carbonising systems• food processing plants.

Pharmaceutical and related industry• purification systems• pure-water systems (WFI)• personal care industries.

Other industrial applications• surface treatment systems• water processing systems• CIP feeding systems.

ConstructionContra pumps are single-stage or multi-stage, end-suction centrifugal pumps.

The pumps are available in a variety of flexible ver-sions. The pumps are CIP and SIP capable in compli-ance with the DIN EN 12462 performance criteria. They also meet the GMP requirements regarding FDA-approved materials.

The design complies with:

• QHD criteria• EHEDG recommendations• 3A Sanitary Standards.

Fig. 8 Certification

Requirements complied with:

Standard pump version:3A1Optional: 3A2, 3A3.

For explanation, see Certification, page 25.

The pump housing is made of rolled and forged stain-less steel to DIN EN 1.4404/1.4435, the equivalent of AISI 316L. This guarantees a homogeneous, pore-free surface, in contrast to cast materials.

The Contra pumps have open diffusers. The O-ring seal locations for the housing and impellers are designed to meet the criteria of hygienic design with metal-to-metal contact seal areas and no pump housing dead-ends.

Contra pumps are fitted with a semi-open impeller as standard. See page 23.

The vertical versions are fully self-draining through the suction port of the pumps.

The pumps have a mechanical shaft seal and a fan-cooled asynchronous motor with enclosure to IP 55.

Fig. 9 Sectional drawing of Contra I Bloc-SUPER on combi foot

GR

8961

Head: up to 160 mFlow rate: up to 55 m3/hOperating pressure: up to 25 barOperating temperature: 95°C

(up to 150°C on request)Sterilisation temperature: 140°C (SIP)

TM02

961

0 35

04

1 4 5 6

2 3 7

Page 11: GRUNDFOS DATA BOOKLET - Unopomp7 Euro-HYGIA® Sanitary pumps Materials Design variations See page 27. Mechanical shaft seal Grundfos offers these seal arrangements: • single seal

Contra Sanitary pumps

Materials

Design variations

See page 27

Mechanical shaft sealGrundfos offers these seal arrangements:

• single seal• double tandem seal• double back-to-back seal.As standard, the Contra is fitted with a single, inboard, mechanical shaft seal with an optimum position in the pumped liquid. This ensures lubrication, cooling as well as CIP and SIP according to the criteria of hygienic design.

Standard seals have carbon/stainless steel seal faces and EPDM O-rings. Other seal face material combina-tions are available on request.

See page 24.

Surface treatmentAs standard, all wetted parts are electro-polished to improve corrosion-resistance and surface finish.

ConnectionsDepending on the nominal diameter of the Contra pump, Grundfos offers the below pipe connections as standard:

• threads to DIN 11851, PN 25-40• flanges to DIN EN 1092-1, PN 10 (DIN 2642,

PN 10) (industrial applications only)• pipe threads to DIN ISO 228, PN 10 (max.)• sterile threads to DIN 11864-1, PN 16• sterile flanges to DIN 11864-2, PN 16.Other connections are available on request, such as SMS, RJT, clamp connections to DIN and ISO, Tri-Clover® connections as well as special sterile threaded fittings and flanges.

See pages 34 to 39.

Features and benefits• A wide range of support options for motor and pump• Extremely reliable operation under most working

conditions• Optimised hydraulics for high efficiency

- reduced power consumption• Contra Adapta® and CN with explosion-proof or

flameproof motors available for ATEX applications• Motors with special voltages and frequencies• Pump with water-cooled motor for clean-room appli-

cations• Adapta® tronic versions fitted with motors for varia-

ble speed drive with built-in frequency converter, available for motor sizes up to 7.5 kW

• Flush or barrier fluid systems for tandem or back-to-back double mechanical seals

• Mobile pumps mounted on two-wheel trolley with on/off switch

• Special paint for motor, cast iron and carbon steel parts (except for Adapta® Bloc).

Pos. Component Material EN/DIN

1 Impeller CrNiMo steel 1.4404/1.4435

2 Pump housing CrNiMo steel 1.4404/1.4435

3 Shaft sealSterile applications: SiC/SiC/EPDMHygienic applications: Carbon/stainless steel/EPDM or FKM

4 Pump shaft CrNiMo steel 1.4571/1.4462

5 Motor6 Shroud Stainless steel7 Support Stainless steel/cast iron

Standard variation DescriptionContra Adapta® Horizontal installation, Adapta® motor stool

Contra Adapta® SUPER Horizontal installation, Adapta® motor stool, motor with stainless steel shroud

Contra Adapta®-V Vertical installation, Adapta® motor stoolContra Bloc Horizontal installation

Contra Bloc-SUPER Horizontal installation, motor with stainless steel shroud

Variation on request DescriptionContra Bloc-V Vertical installation

Contra CN Horizontal installation, long-coupled version mounted on base plate

Contra tronic Horizontal/vertical installation, motor with built-in frequency converter (up to 7.5 kW)

11

Page 12: GRUNDFOS DATA BOOKLET - Unopomp7 Euro-HYGIA® Sanitary pumps Materials Design variations See page 27. Mechanical shaft seal Grundfos offers these seal arrangements: • single seal

12

Sanitary pumpsdurietta 0

durietta 0

Fig. 10 durietta 0

Technical data

durietta 0 pumpsHead: up to 70 m

Flow rate: up to 6 m3/h

Operating pressure: up to 8 bar

Temperature range: 0°C to 90°C.

ApplicationsThe unique hygienic design and the materials used make the durietta 0 pump range suitable for:

Food and beverage• pumping of liquids in micro breweries and dairies• bottling systems for liquids• food processing plants• drinking water systems.

Pharmaceutical and related industry• purification systems• personal care industries.

Other industrial applications• semi-conductor manufacturing• CIP systems• plate heat exchangers.

Constructiondurietta 0 pumps are compact, end-suction, single-stage or multistage centrifugal pumps, designed in compliance with the 3A criteria (3A0.01 and 3A1.02). The vertical version has a special mounting foot with a fixed suction elbow.

The pumps are compatible with CIP systems.

Fig. 11 Certification

For explanation, see Certification, page 25.

The laminated, stainless steel pump components are manufactured to EN 1.4571 and EN 1.4404.

The impeller types available are of the semi-open or closed type, depending on the applications.See page 23.

The pumps have a mechanical shaft seal and an asyn-chronous motor with enclosure to IP 55.

Fig. 12 Sectional drawing of durietta 0/2 K SUPER on combi foot

Materials

GrA

2397

TM03

378

2 10

06

Pos. Component Material EN/DIN 1 Impeller CrNiMo steel 1.44042 Pump housing CrNiMo steel 1.4404

3 Shaft sealSiC/SiCCarbon/stainless steelJoints: EPDM or FKM

4 Pump shaft CrNiMo steel 1.45715 Motor6 Shroud Stainless steel 1.43077 Support Stainless steel 1.4307

2 1 5 6

4 3 7

Page 13: GRUNDFOS DATA BOOKLET - Unopomp7 Euro-HYGIA® Sanitary pumps Materials Design variations See page 27. Mechanical shaft seal Grundfos offers these seal arrangements: • single seal

durietta 0 Sanitary pumps

Design variations

See page 27.

Mechanical shaft sealGrundfos offers these seal arrangements:

• single seal• double tandem seal (maximum four stages)• double back-to-back seal (maximum four stages).The standard, mechanical shaft seals have an optimum position in the pump housing. This ensures lubrication and cooling of the mechanical shaft seal in accordance with the criteria of the hygienic design.

Standard seals have carbon/stainless steel seal faces and EPDM O-rings. Other seal face material combina-tions are available on request.

See page 24.

Surface treatmentWetted parts are blasted as standard. Electro-polished wetted parts are also available on request.

ConnectionsGrundfos offers the following pipe connections for durietta 0 as standard:

• threads to DIN 11851, PN 25-40• SMS threads• clamps to SMS and ISO• flange to DIN EN 1092-1, PN 10 (DIN 2642, PN 10)• threads to DIN ISO 228 (male) - GAZ, PN 10• tapped connection to DIN ISO 2999 - GAZ, PN 10Other connections are available on request, such as flange or sterile threaded fittings, DIN 11864.

See pages 40 to 44.

Features and benefits• Motor for special voltages and frequencies

(NEMA, UL, CSA, etc.) on request• Motor with built-in frequency converter for output

regulation (not available in K SUPER execution)• Mobile pumps mounted on stainless steel trolley

with on/off switch (on request)• Special paint finish for the motor (on request).

Standard variation Descriptiondurietta 0 K Horizontal installation, monobloc

durietta 0 K SUPERHorizontal installation, motor with stainless steel shroud on stainless steel foot with elastomer base

durietta 0 K V Vertical installation, monoblocVariation on request Description

durietta 0 K V-SUPER Vertical installation with stainless steel shroud

durietta 0 tronic Horizontal/vertical installation, motor with built-in unshrouded frequency converter

13

Page 14: GRUNDFOS DATA BOOKLET - Unopomp7 Euro-HYGIA® Sanitary pumps Materials Design variations See page 27. Mechanical shaft seal Grundfos offers these seal arrangements: • single seal

14

Sanitary pumpsSIPLA

SIPLA

Fig. 13 SIPLA

Technical data

SIPLA pumps

ApplicationsThe unique hygienic design, the materials used and its exceptional self-priming capability make the SIPLA pump range suitable for:

Food and beverage• transfer of yeast• transfer of cheese whey.

Pharmaceutical industry• transfer of glycerine.

Other industrial applications• CIP-return pumping• applications involving liquids with a high air content• filtration systems.

ConstructionSIPLA pumps are single-stage, self-priming, side-channel pumps.

The design complies with the 3A Sanitary Standards (3A1).

Fig. 14 Certification

For explanation, see Certification, page 25.

The pump housing and front cover are made of preci-sion-cast stainless steel to DIN EN 1.4404. The impel-ler nut is made of stainless steel to DIN EN 1.4435, the equivalent of AISI 316L.

SIPLA pumps are fitted with an open star impeller as standard. See page 23.

The pump shaft is made of stainless steel to DIN EN 1.4571, the equivalent of AISI 316TI.

Thanks to its unique side-channel design, the SIPLA pump is capable of handling liquids with a high air con-tent as in CIP-return systems.

The pumps have a mechanical shaft seal and a fan-cooled asynchronous motor with enclosure to IP 55.

Fig. 15 Sectional drawing of SIPLA Bloc-SUPER on stainless steel ball feet

GR

8965

Head: up to 56 mFlow rate: up to 80 m3/h(SIPLA 90.1 - on request): up to 90 m3/hOperating pressure: up to 10 barOperating temperature: 95°C Sterilisation temperature: 140°C (SIP)

TM02

960

8 35

04

2 4 5 6

1 7 3 7

Page 15: GRUNDFOS DATA BOOKLET - Unopomp7 Euro-HYGIA® Sanitary pumps Materials Design variations See page 27. Mechanical shaft seal Grundfos offers these seal arrangements: • single seal

SIPLA Sanitary pumps

Materials

Design variations

See page 27.

Mechanical shaft sealSIPLA pumps are fitted with a single, inboard, mechan-ical shaft seal with an optimum position in the pumped liquid. This ensures efficient CIP, SIP, cooling and lubri-cation.

As standard, the SIPLA pump is fitted with a shaft seal with carbon/stainless steel seal faces and EPDM or FKM O-rings.Shaft seals with SiC/SiC seal faces and EPDM or FKM O-ring are available on request.

See page 24.

Surface treatmentAs standard, all wetted parts are electro-polished to improve corrosion-resistance and surface finish.

ConnectionsDepending on the nominal diameter of the SIPLA pump, Grundfos offers threaded pipe connections to DIN 1851.

The following optional threaded connections are avail-able: SMS, RJT, IDF clamp connections to DIN and clamps for Tri-Clamp®/Tri-Clover®.

Product features and benefits• A wide range of support options for motor and pump• Extremely reliable operation under most working

conditions• Optimised hydraulics for high efficiency

- reduced power consumption• Motors for variable speed drive with built-in

frequency converter, "tronic", available for motor sizes up to 7.5 kW

• ATEX-certified pumps available on request• Mobile pumps mounted on two-wheel trolley with

on/off switch.

Pos. Component Material EN/DIN 1 Impeller CrNiMo steel 1.44042 Pump housing CrNiMo steel 1.4404

3 Shaft sealHygienic applications:Carbon/stainless steel/EPDM or FKM

4 Pump shaft CrNiMo steel 1.45715 Motor6 Shroud Stainless steel7 Support Stainless steel/cast iron

Standard variation Description

SIPLA Adapta® SUPER Horizontal installation, Adapta® motor stool, motor with stainless steel shroud

SIPLA Bloc Horizontal installation

SIPLA Bloc-SUPER Horizontal installation, motor with stainless steel shroud

Variation on request Description

SIPLA CN Horizontal installation, long-coupled version mounted on base plate

SIPLA tronicHorizontal/vertical installation, motor with built-in frequency converter (up to 7.5 kW)

15

Page 16: GRUNDFOS DATA BOOKLET - Unopomp7 Euro-HYGIA® Sanitary pumps Materials Design variations See page 27. Mechanical shaft seal Grundfos offers these seal arrangements: • single seal

16

Sanitary pumpsMAXA and MAXANA

MAXA and MAXANA

Fig. 16 MAXANA and MAXA

Technical data

MAXA pumps

MAXANA pumps

ApplicationsThe MAXA and MAXANA pump ranges are suitable for:

Food and beverage• gentle pumping of mash and wort, and beer filtration

(hot side)• liquid transfer in dairies and food plants.

Other industrial applications• water treatment plants• chemical handling systems• applications involving liquids with a high content of

solid particles• environmental systems.

ConstructionThe MAXA and MAXANA pumps are single-stage, end-suction, centrifugal pumps, designed for industrial processes.

The pumps are available in a variety of flexible ver-sions.

Requirements complied with:

For explanation, see Certification, page 25.

The major dimensions and characteristics of the pumps are according to DIN EN 733 and DIN EN 22858.

The pump housing are made of heavy-duty, rolled and deep-drawn stainless steel to DIN EN 1.4404. The back plate is made of rolled stainless steel to DIN EN 1.4571.

The pumps feature closed steel impellers with opti-mised blade entry angles to DIN EN 1.4571. See page 23.

Fig. 17 Sectional drawing of MAXANA-CN on base plate

TM03

017

0 43

04

Head: 97 mFlow rate: up to 820 m3/hOperating pressure: up to 10 barOperating temperature: 95°C

(up to 150°C on request)Sterilisation temperature: 140°C (SIP)

Head: up to 97 mFlow rate: up to 165 m3/hOperating pressure: up to 10 barOperating temperature: 95°C

(up to 150°C on request)Sterilisation temperature: 140°C (SIP)

Pump type StandardMAXANA 3A0MAXA 3A0 and 3A2*.* Applies to MAXA 100-200, 100-250, 125-250, 150-250, 200-400

TM02

960

9 35

04

2 5 4 6 7

1 3 8

Page 17: GRUNDFOS DATA BOOKLET - Unopomp7 Euro-HYGIA® Sanitary pumps Materials Design variations See page 27. Mechanical shaft seal Grundfos offers these seal arrangements: • single seal

MAXA and MAXANA Sanitary pumps

Materials

Design variations

See page 27.

Mechanical shaft sealGrundfos offers these seal arrangements:

• single seal• double tandem seal• double back-to-back seal.As standard, MAXA and MAXANA pumps are fitted with a single, inboard, mechanical shaft seal with an opti-mum position in the pumped liquid. This ensures effi-cient cleaning, cooling and lubrication.

The mechanical shaft seal is designed to DIN EN 12756.

Standard single seals have carbon/stainless steel seal faces and EPDM O-rings. Other seal face material com-binations are available on request.

See page 24.

Surface treatmentAs standard, all wetted parts are made of corrosion-resistant chrome-nickel-molybdenum steel.

Grundfos offers industrial, electro-polished variants.

ConnectionsDepending on the nominal diameter of the MAXA and MAXANA pumps, Grundfos offers a standard flanged connection to DIN EN 1092-1, PN 10 (DIN 2632, PN 10).

Optional connections include connections designed to ANSI and JIS standards.

Features and benefits• A wide range of support options for motor and pump• Extremely reliable operation under most working

conditions• Optimised hydraulics for high efficiency

- reduced power consumption• Optional location of discharge port on top, on right

or on left side of pump• Double mechanical seals, depending on model, with

flushing or barrier fluid• Packed gland as shaft seal, single or flushed with C-

bearing support to DIN EN 22858 and shaft sleeve• Motors with special voltages and frequencies• Adapta® and CN available with a flameproof three-

phase motor for ATEX applications• Motors for variable speed drive with built-in fre-

quency converter as "tronic", available for motor sizes up to 7.5 kW

• Housing drain connection DN 15; other sizes availa-ble

• Housing with heating jacket• Special paint for motor and steel components• MAXA Adapta® and MAXANA Adapta® pumps avail-

able with trolley.

Pos. Component Material EN/DIN

1 Impeller CrNiMo steel 1.4404/1.4462

2 Pump housing CrNiMo steel 1.4404

3 Shaft seal

Sterile applications: SiC/SiC/EPDMHygienic applications: Carbon/stainless steel/EPDM or FKM

4 Pump shaft CrNiMo steel 1.4571/1.4462

5 Bearing bracket Stainless steel6 Coupling7 Motor

8 Base plate SteelChrome steel

Standard variation DescriptionMAXA L Horizontal installation

MAXA CN Horizontal installation, mounted on base plate

MAXANA Adapta® Horizontal installation, Adapta® motor stool

MAXANA Bloc Horizontal installationVariation on request Description

MAXA CN Horizontal installation, mounted on base plate

Maxa VE Vertical tank installation

MAXA tronic Horizontal installation, motor with built-in frequency converter (up to 7.5 kW)

MAXANA CN Horizontal installation, mounted on base plate

MAXANA L Horizontal installation, mounted on pump foot or motor foot

MAXANA tronic Horizontal installation, motor with built-in frequency converter (up to 7.5 kW)

17

Page 18: GRUNDFOS DATA BOOKLET - Unopomp7 Euro-HYGIA® Sanitary pumps Materials Design variations See page 27. Mechanical shaft seal Grundfos offers these seal arrangements: • single seal

Sanitary pumps

18

Identification

Type keys

Euro-HYGIA®

F&B-HYGIA®

Contra

durietta 0

SIPLA

MAXA

MAXANA

Example Euro-HYGIA® I Bloc 40 32 2.2 4

Pump range

Size

Design

Nominal diameter of suction port (DN)

Nominal diameter of discharge port (DN)

Motor power (P2)

Number of poles

Example F&B-HYGIA® I K 40 40 2.2 4

Pump range

Size

Design

Nominal diameter of suction port (DN)

Nominal diameter of discharge port (DN)

Motor power (P2)

Number of poles

Example Contra I/1 Bloc 32 25 1.5 2Pump range

Size/stages

Design

Nominal diameter of suction port (DN)

Nominal diameter of discharge port (DN)

Motor power (P2)

Number of poles

Example durietta 0/2 K 32 25 0.55 2Pump range

Size/stages

Design

Nominal diameter of suction port (DN)

Nominal diameter of discharge port (DN)

Motor power (P2)

Number of poles

Example SIPLA 3.1 Bloc 32 32 0.75 4Pump range

Size

Design

Nominal diameter of suction port (DN)

Nominal diameter of discharge port (DN)

Motor power (P2)

Number of poles

Example MAXA 80-250 CN 100 80 37 2Pump range

Size

Design

Nominal diameter of suction port (DN)

Nominal diameter of discharge port (DN)

Motor power (P2)

Number of poles

Example MAXANA 32-200 Bloc 50 32 5.5 2Pump range

Size

Design

Nominal diameter of suction port (DN)

Nominal diameter of discharge port (DN)

Motor power (P2)

Number of poles

Page 19: GRUNDFOS DATA BOOKLET - Unopomp7 Euro-HYGIA® Sanitary pumps Materials Design variations See page 27. Mechanical shaft seal Grundfos offers these seal arrangements: • single seal

19

Sanitary pumpsProduct data

Product range

Pump range

Eur

o-H

YGIA

® I

Eur

o-H

YGIA

® II

F&B

-HYG

IA®

I

F&B

-HYG

IA®

II

Con

tra

I

Con

tra

II

duri

etta

0

SIP

LA 3

.1

SIP

LA 6

.1

SIP

LA 1

2.1

SIP

LA 1

8.1

SIP

LA 2

8.1

SIP

LA 5

2.1

SIP

LA 6

5.1

SIP

LA 9

0.1

MA

XA

MA

XAN

A

Hydraulic dataMax. head [m] 43 70 43 70 105 160 70 23 34 25 28 38 36 56 44 98 98Max. rate [m3/h] 39 108 39 105 23 53 6 4.5 6 12 18 26 42 65 80 800 165Max. operating temperature [°C] 95 95 95 95 95 95 90 95 95 95 95 95 95 95 95 95 95Max. temperature [°C]– on request 150 150 150 150 140 140 - 140 140 140 140 140 140 140 140 150 150

Max. operating pressure [bar] 16 16 16 16 25 25 8 10 10 10 10 10 10 10 10 10 10Max. pump efficiency [%] 62 68 62 68 55 62 45 16.5 18.5 24 24 29 30 34 35 87 72Motor data

Motor power [kW] 0.55-5.5

0.75-22

1.1-5.5

2.2-18.5

0.55-5.5

0.75-18.5

0.25-2.2

0.55-0.75

1.5-2.2

1.5-2.2

3-4

4-5.5

7.5-11

11-15

18.5-22

3-90

0.55-55

DesignBloc Bloc SUPERBloc-VVEAdapta®

Adapta® SUPERAdapta®-VKK SUPERK-V CNLTronicMaterialsPump housing:CrNiMo stainless steel 1.4404Pump housing:Stainless steel 1.4404/1.4435Pipe connectionsThreads, DIN 11851, PN 25-40Threads, DIN ISO 228, PN 10Sterile threads, DIN 11864-1, PN 16Flanges, DIN EN 1092-1(DIN 2632)Flanges, DIN EN 1092-1(DIN 2642)Sterile flanges,DIN 11864-2, PN 16SMSRJTDIN clampClamps for Tri-Clamp®/Tri-Clover®

Special, sterile threaded fittings and flangesImpeller typesSemi-open Closed Two-channel (closed)Free-flowStar

Standard.Available on request.

Page 20: GRUNDFOS DATA BOOKLET - Unopomp7 Euro-HYGIA® Sanitary pumps Materials Design variations See page 27. Mechanical shaft seal Grundfos offers these seal arrangements: • single seal

20

Sanitary pumpsConstruction

MotorThe motor is a totally enclosed, fan-cooled standard motor with main dimensions to IEC and DIN standards. Electrical tolerances to IEC 34.

Mounting designation

In humid locations, the lowest drain hole in the motor must be opened. In such cases, the motor enclosure class is IP 44.

Motor ranges

Euro-HYGIA® I

Euro-HYGIA® II

F&B-HYGIA® II

F&B-HYGIA® II

Contra I

Contra II

Pump rangeMounting designation - IEC 34-7

Horizontal installation Vertical installationEuro-HYGIA®

IM 1001 (IM B3)IM 3001 (IM B5)

IM 2001 (IM B35)

IM 1011 (IM V5)IM 3011 (IM V1)

IM 2011 (IM V15)

F&B-HYGIA®

ContraSIPLAMAXAMAXANAdurietta 0 IM 2001 (IM B35) IM 3011 (IM V1)

Relative humidity: Max. 95%Enclosure class: IP 55Insulation class: F, to IEC 85Ambient temperature: Max. 40°C

P2 kW 2-pole 4-pole0.550.751.11.52.23.04.05.5

The grey shaded areas indicate non-available motors.

P2 kW 2-pole 4-pole0.751.11.52.23.04.05.57.511.015.018.522.0

The grey shaded areas indicate non-available motors.

P2 kW 2-pole 4-pole0.550.751.11.52.23.04.05.5

The grey shaded areas indicate non-available motors.

P2 kW 2-pole 4-pole0.751.11.52.23.04.05.57.511.015.018.5

The grey shaded areas indicate non-available motors.

P2 kW

2-pole 4-pole

1-st

age

2-st

age

3-st

age

4-st

age

5-st

age

6-st

age

1-st

age

0.550.751.11.52.23.04.05.5

The grey shaded areas indicate non-available motors.

P2 kW

2-pole 4-pole

1-st

age

2-st

age

3-st

age

4-st

age

5-st

age

1-st

age

0.751.11.52.23.04.05.57.511.015.018.5

The grey shaded areas indicate non-available motors.

Page 21: GRUNDFOS DATA BOOKLET - Unopomp7 Euro-HYGIA® Sanitary pumps Materials Design variations See page 27. Mechanical shaft seal Grundfos offers these seal arrangements: • single seal

Construction Sanitary pumps

durietta 0

SIPLA

MAXA, 2-pole

MAXA, 4-pole

MAXANA, 2-pole

MAXANA, 4-pole

P2 kW

2-pole 4-pole

1-st

age

2-st

age

3-st

age

4-st

age

5-st

age

6-st

age

1-st

age

0.250.370.550.751.11.52.2

The grey shaded areas indicate non-available motors.

P2 kW4-poleSize

3.1 6.1 12.1 18.1 28.1 52.1 65.1 90.10.550.751.11.52.23.04.05.57.511.015.018.5

The grey shaded areas indicate non-available motors.

P2 kW

2-poleSize

80-1

60

80-2

00

80-2

50

100-

200

100-

250

7.511.015.018.522.030.037.045.055.075.090.0

The grey shaded areas indicate non-available motors.

P2 kW

4-poleSize

80-1

60

80-2

00

80-2

50

80-3

15

100-

200

100-

250

100-

315

125-

250

125-

315

150-

250

150-

315

150-

400

200-

400

3.04.05.57.511.015.018.522.030.037.045.055.075.090.0

The grey shaded areas indicate non-available motors.

P2 kW

2-poleSize

32-1

60

32-2

00

40-1

60

40-2

00

50-1

25

50-1

60

50-2

00

65-1

25

65-1

60

65-2

00

65-2

50

2.23.04.05.57.511.015.018.522.030.037.045.055.0

The grey shaded areas indicate non-available motors.

P2 kW

4-poleSize

32-1

60

32-2

00

40-1

60

40-2

00

50-1

25

50-1

60

50-2

00

65-1

25

65-1

60

65-2

00

65-2

50

0.550.751.11.52.23.04.05.5

The grey shaded areas indicate non-available motors.

21

Page 22: GRUNDFOS DATA BOOKLET - Unopomp7 Euro-HYGIA® Sanitary pumps Materials Design variations See page 27. Mechanical shaft seal Grundfos offers these seal arrangements: • single seal

22

Construction Sanitary pumps

Electrical data of standard motors

2-pole, 3 x 220-240/380-415 V

2-pole, 3 x 380-415/660-690 V

4-pole, 3 x 220-240/380-415 V

4-pole, 3 x 380-415/660-690 V

Electrical data of standard motors with built-in frequency converter

2-pole, 3 x 380-415 V

4-pole, 3 x 380-415 V

The values depend on the motor make.

Motor protectionThree-phase motors must be connected to a motor starter.

All three-phase standard motors can be connected to an external frequency converter. The connection of a frequency converter will often overload the motor insu-lation system, and the motor will be more noisy than during normal operation. In addition, large motors are loaded by bearing currents caused by the frequency converter.

In the case of frequency converter operation, bear in mind:

• In 2- and 4-pole motors of frame size 250 and up-wards, one of the motor bearings should be electri-cally isolated to prevent damaging currents from passing through the motor bearings.

• In the case of noise-sensitive applications, the motor noise can be reduced by fitting a dU/dt filter between the motor and the frequency converter. In particularly noise-sensitive applications, we recommend to fit a sinusoidal filter.

• The length of the cable between motor and fre-quency converter affects the motor load. It should therefore be checked that the cable length meets the specifications laid down by the frequency con-verter supplier.

• For supply voltages between 500 and 690 V, fit a dU/dt filter to reduce voltage peaks or use a motor with reinforced insulation.

• For supply voltages of 690 V, use a motor with reinforced insulation and fit a dU/dt filter.

P2 [kW] I1/1 [A] cosφ η[%] n [min-1]0.37 1.0 0.82 66 27400.55 1.36 0.82 71 28000.75 1.73 0.86 73 28551.1 2.40 0.87 77 28451.5 3.25 0.85 79 28602.2 4.55 0.85 82 2880

P2 [kW] I1/1 [A] cosφ η[%] n [min-1]3.0 6.1 0.85 84 28904.0 7.8 0.86 86 29055.5 10.3 0.89 86.5 29257.5 13.8 0.89 88 293011.0 20.0 0.88 89.5 294015.0 26.5 0.90 90 294018.5 32.5 0.91 91 294022.0 39.0 0.88 91.7 294030.0 53.0 0.89 92.3 294537.0 65.0 0.89 92.8 294545.0 78.0 0.89 93.6 296055.0 96.0 0.88 93.6 297075.0 130.0 0.88 94.5 297590.0 154.0 0.89 95.1 2975

P2 [kW] I1/1 [A] cosφ η[%] n [min-1]0.25 0.75 0.78 60 13500.55 1.45 0.82 67 13950.75 1.86 0.81 72 13951.1 2.55 0.81 77 14151.5 3.40 0.81 79 14202.2 4.70 0.82 82 1420

P2 [kW] I1/1 [A] cosφ η[%] n [min-1]3.0 6.40 0.82 83 14204.0 8.20 0.83 85 14405.5 11.4 0.81 86 14557.5 15.2 0.82 87 145511.0 21.5 0.84 88.5 146015.0 28.5 0.84 90 146018.5 35.0 0.83 90.5 146022.0 41.0 0.84 91.2 146030.0 55.0 0.86 91.8 146537.0 66.0 0.87 92.9 147045.0 80.0 0.87 93.4 147055.0 100.0 0.85 93.5 148075.0 136.0 0.85 94.2 148590.0 160.0 0.86 94.6 1485

P2 [kW] I1/1 [A]

1.1 2.41.5 3.252.2 4.553.0 6.14.0 7.85.5 10.37.5 13.8

P2 [kW] I1/1 [A]

1.1 2.551.5 3.42.2 4.73.0 6.44.0 8.25.5 11.47.5 15.2

Page 23: GRUNDFOS DATA BOOKLET - Unopomp7 Euro-HYGIA® Sanitary pumps Materials Design variations See page 27. Mechanical shaft seal Grundfos offers these seal arrangements: • single seal

Construction Sanitary pumps

Impeller typesGrundfos offers four impeller types suitable for different liquids and applications.Not all impeller types are available for the complete product range.

Semi-open impeller

Fig. 18 Semi-open impeller

Above impeller design is not fitted in durietta 0.

The electro-polished, stainless steel, semi-open impeller type is available in three versions, according to the application.

For surface finish requirements, see page 26.

The impeller is suitable for low-viscosity liquids and liquids containing particles.

Closed impeller

Fig. 19 Closed impeller

Above impeller designs are not fitted in durietta 0.

The two electro-polished, stainless steel. closed impeller types are available in two versions, according to the application.

For surface finish requirements, see page 26.

The two-channel impeller is suitable for pumped liquids containing solid particles.

The closed impeller is suitable for pumped liquids with a low content of solid particles. This impeller type has the highest efficiency.

Free-flow impeller

Fig. 20 Free-flow impeller

This electro-polished stainless steel, impeller type is available in two versions, according to the application.

For surface finish requirements, see page 26.

The free-flow impeller is a non-clogging impeller designed for pumped liquids with a high content of solid particles or fibres.

Star impeller

Fig. 21 Star impeller

This electro-polished, cast, stainless steel impeller type is suitable for industrial/hygienic applications.

For surface finish requirements, see page 26.

The highly efficient, self-priming star impeller is suitable for pumped liquids with a low content of solid particles.

Surface treatmentAll non-wetted parts of the pumps receive the following surface treatment:

1. Priming colour- Epoxy resin (RAL 7032)- Thickness of film: 50 to 70 µm.

2. Top coat (standard)- Epoxy resin (RAL 5010)- Thickness of film: 50 to 70 µm.

The durietta 0 receives a single coat of polyurethane (RAL 5010) of a thickness of 30 to 40 µm.

GR

9394

Impeller version Application Surface finishCast Industrial/hygienic 3A0 to 3A1Welded Industrial/hygienic 3A0 to 3A1Milled Industrial/hygienic/sterile 3A2 to 3A3

GR

9391

- G

R93

92

Impeller version Application Surface finishCast Industrial/hygienic 3A0 to 3A1Welded Industrial/hygienic 3A0 to 3A1

Two-channel, closed Closed

GR

9393

Impeller version Application Surface finishCast Industrial/hygienic 3A0 to 3A1Welded Industrial/hygienic 3A0 to 3A1

GR

A03

93p

Impeller version Application Surface finishCast Industrial/hygienic 3A0 to 3A1

23

Page 24: GRUNDFOS DATA BOOKLET - Unopomp7 Euro-HYGIA® Sanitary pumps Materials Design variations See page 27. Mechanical shaft seal Grundfos offers these seal arrangements: • single seal

Sanitary pumps

24

Shaft seals

Mechanical shaft sealThe operating range of the shaft seal depends on the type of seal, the operating pressure and the liquid tem-perature.

Only standard shaft seals are described below; other shaft seals are available on request.

Hygienic applicationsAs standard, Grundfos offers a single shaft seal fitted with a metal spring as seal driver. The seal is suitable for hygienic applications.

Fig. 22 Single seal for hygienic applications.

The single shaft seal has carbon/stainless steel seal faces and EPDM or FKM O-rings.

Fig. 23 Operating range of shaft seal with metal spring as seal driver for hygienic applications

1: Carbon/stainless steel + EPDM2: Carbon/stainless steel + EPDM and

carbon/stainless steel + FKM.

Sterile applicationsAs standard, Grundfos offers a closed O-ring seal for sterile applications.

Fig. 24 Single seal for sterile applications.

The O-ring seal has SiC/SiC seal faces and O-rings of EPDM (optionally FFKM (white) or FKM).

Fig. 25 Operating range of closed O-ring seal for sterile applications.

Seals for sanitary pumps

TM02

966

0 36

04TM

03 0

121

4104

10

5

00 -40 0 20 40 80

p [bar]

-20 60 100t [˚C]

15

21

TM02

966

4 36

04TM

03 0

118

4104

Shaft seal

Pump range

Euro

-HYG

IA®

F&B

-HYG

IA®

Con

tra

duri

etta

0

SIPL

A

MA

XA

MA

XAN

A

Single sealQuenchTandem *Back-to-back *

Standard.On request.

* Maximum 4 stages.

SiC/

SiC/

EPDM

SiC/SiC/EPDMSiC/SiC/FFKMSiC/SiC/FKM

25

20

15

10

00 -40 0 20 40 80

p [bar]

5

-20 60 100t [˚C]

30

Page 25: GRUNDFOS DATA BOOKLET - Unopomp7 Euro-HYGIA® Sanitary pumps Materials Design variations See page 27. Mechanical shaft seal Grundfos offers these seal arrangements: • single seal

Sanitary pumpsCertification

Approvals and certificatesThe design, materials used and surface finish are sub-ject to a variety of national and international rules and regulations, such as the 3A Sanitary Standards, the EHEDG recommendations and the QHD criteria.

3A Sanitary Standards

Fig. 26 3A symbol

The 3A Sanitary Standards for design and manufacture provide material specifications and requirements for surface finish.

This ensures that dairy, food and other microbially sen-sitive products are protected from contamination and that all product contact surfaces can be cleaned in place (CIP) or easily dismantled for manual cleaning.

The 3A symbol is used by manufacturers to indicate compliance with the 3A Sanitary Standards.

For information on the surface finish of hygienic pumps, see page 26.

EHEDG

Fig. 27 EHEDG symbol

The EHEDG (European Hygienic Engineering & Design Group) develops guidelines and test methods for the safe and hygienic processing of food.

This ensures the microbiological safety of the end prod-uct, for example the pumped medium.

The EHEDG symbol is used by manufacturers to indi-cate compliance with the EHEDG recommendations.

QHD

Fig. 28 QHD symbol

The QHD (Qualified Hygienic Design) is a two-phase testing system for the hygienic design and cleanability of components, machinery and plant for aseptic or sterile applications.

This ensures that all surfaces can be cleaned in place (CIP).

The QHD symbol is used by manufacturers to indicate compliance with the QHD criteria.

CertificatesGeneral informationGrundfos offers the following certificates and approvals:

• Hygienic design certificates(certificates guaranteeing compliance with the 3A Sanitary Standards as well as the EHEDG and QHD criteria)

• Material certificates(certificates stating material specifications)

• Performance certificates(test reports guaranteeing and certifying test data of QH, current consumption, speed, curves, etc.)

• Authorized test by third party(surveyed performance test)

• ATEX-approved sanitary pumps(according to ATEX Directive 94/9/EC)

The certificates must be ordered with the pump.

A3E

HE

DG

QH

D

25

Page 26: GRUNDFOS DATA BOOKLET - Unopomp7 Euro-HYGIA® Sanitary pumps Materials Design variations See page 27. Mechanical shaft seal Grundfos offers these seal arrangements: • single seal

26

Certification Sanitary pumps

Surface finish of hygienic pumpsIn order to meet the demands of the pharmaceutical, food and beverage industries, Grundfos has developed the below surface finish requirements:

TM03

009

1 39

04

Certificate Standard3A sanitary design certificateEHEDG test reportQHD test reportMaterial specification reportMaterial report with certificateCE declaration of conformityATEX-approved pump Inspection certificate EN 10.204 3.1Inspection certificate- Lloyds Register of Shipping (LRS) - Det Norske Veritas (DNV)- Germanischer Lloyd (GL)- Bureau Veritas (BV), etc.

EN 10.204 3.1

Surface roughness reportMotor test reportStandard test report ISO 9906Vibration reportCertificate of compliance with the order EN 10.204 2.1Test report - non-specific inspection and testing EN 10.204 2.2

ReportCleaned and dried pumpReportElectro-polished pump

Code Application Material Surface finish3A0.01 Industrial CrNiMo steel3A1.02 Hygienic CrNiMo steel Ra≤3.2μm

3A2.03 Sterile 1.4404/1.4435(AISI 316L) Ra≤0.8μm

3A1.04 Pharmaceutical 1.4435, Fe≤3% Ra≤3.2μm3A2.05 Sterile 1.4435, Fe≤1% Ra≤0.8μm3A3.06 Sterile 1.4435, Fe≤1% Ra≤0.4μm

3A3.07 Sterile 1.4404/1.4435(AISI 316L) Ra≤0.4μm

3A2.33 Sterile1.4404/1.4435Fe≤3%(AISI 316L)

Ra≤0.8μm

3A3.37 Sterile1.4404/1.4435Fe≤3%(AISI 316L)

Ra≤0.4μm

Page 27: GRUNDFOS DATA BOOKLET - Unopomp7 Euro-HYGIA® Sanitary pumps Materials Design variations See page 27. Mechanical shaft seal Grundfos offers these seal arrangements: • single seal

Sanitary pumpsDesigns and versions

Design variationsGrundfos offers each pump range in different designs. Principal sketches of each design variant are shown below. Not all pumps are available in the design varia-tions shown.

Bloc on motor foot

Fig. 29 Euro-HYGIA® Bloc on motor foot

Bloc on stainless steel foot

Fig. 30 Euro-HYGIA® Bloc on stainless steel foot

Bloc-SUPER

Fig. 31 Euro-HYGIA® Bloc-SUPER with shroud and on stainless steel combi foot

Bloc on stainless steel trolley

Fig. 32 Euro-HYGIA® Bloc on stainless steel trolley

CN

Fig. 33 Euro-HYGIA® CN on base plate

Adapta®

Fig. 34 Euro-HYGIA® Adapta® on cast iron foot

Adapta®-SUPER

Fig. 35 Euro-HYGIA® Adapta®-SUPER on stainless steel combi foot

Adapta® on stainless steel trolley

Fig. 36 Euro-HYGIA® Adapta® on stainless steel trolley

Adapta®-V

Fig. 37 Euro-HYGIA® Adapta®-V on pedestal and with suction elbow connection

VE

Fig. 38 Example: Euro-HYGIA®-VE in tank installation

TM03

007

9 39

04TM

03 0

080

3904

TM03

008

1 39

04TM

03 0

086

3904

TM03

008

5 39

04TM

03 0

082

3904

TM03

008

3 39

04TM

03 0

087

3904

TM03

008

8 39

04TM

03 3

895

1106

27

Page 28: GRUNDFOS DATA BOOKLET - Unopomp7 Euro-HYGIA® Sanitary pumps Materials Design variations See page 27. Mechanical shaft seal Grundfos offers these seal arrangements: • single seal

28

Designs and versions Sanitary pumps

The tables below state possible designs and versions of each pump range.

Each version number is described in the version key, page 30.

Euro-HYGIA® I

Euro-HYGIA® II

F&B-HYGIA® I

F&B-HYGIA® II

Contra I

Contra II

durietta 0

SIPLA 3.1

SIPLA 6.1

Design Version number

Adapta® 1) 1 2 3 18 19 23 24 31 50 51 52 60 61

Adapta®-SUPER 2) 1 2 3 18 19 23 31 50 60 61

Adapta®-V 1) 8 9 10 11 31 50 51 52 60 61

Bloc 1 2 3 5 6 7 18 19 23 24 50 60 61Bloc-SUPER 2) 1 2 3 5 6 7 18 19 23 50 60 61

Bloc-V 8 9 10 11 50 60 61VE 31 50 57 58 59CN 25 26 27 28 29 30 31 32 33 34 50 51 52 60 611) Size I.2) SUPER = motor with stainless steel shroud.

Design Version numberAdapta® 1) 1 2 3 18 19 22 23 24 31 50 51 52 60 61Adapta®-SUPER 2) 1 2 3 18 19 22 23 31 50 60 61

Adapta®-V 1) 8 9 10 11 31 50 51 52 60 61Bloc 1 2 3 5 6 7 18 19 23 24 50 60 61Bloc-SUPER 2) 1 2 3 5 6 7 18 19 23 50 60 61

Bloc-V 8 9 10 11 50 60 61VE 31 50 57 58 59CN 25 26 27 28 29 30 31 32 33 34 50 51 52 60 611) Size II up to frame size 160; frame size 180 is size III.2) SUPER = motor with stainless steel shroud.

Design Version numberK 1) 1 2 3 5 18 19 23 50 51 52 60K-SUPER 2) 1 2 18 19 23 50 60

1) Plug in shaft2) SUPER = motor with stainless steel shroud.

Design Version numberK 1) 1 2 3 5 18 19 23 50 51 52 60K-SUPER 2) 1 2 18 19 23 50 60

1) Plug in shaft.2) SUPER = motor with stainless steel shroud.

Design Version numberAdapta® 1) 1 2 3 18 19 23 24 31 50 51 52Adapta®-SUPER 2) 1 2 3 18 19 23 31 50

Adapta®-V 1) 8 9 10 11 31 50 51 52

Bloc 1 2 3 5 6 7 18 19 23 24 50Bloc-SUPER 2) 1 2 3 5 6 7 18 19 23 50

Bloc-V 8 9 10 11 50CN 25 26 27 28 29 30 31 32 33 34 50 51 52

1) Size I.2) SUPER = motor with stainless steel shroud.

Design Version numberAdapta® 1) 1 2 3 18 19 22 23 24 31 50 51 52Adapta®-SUPER 2) 1 2 3 18 19 22 23 31 50

Adapta®-V 1) 8 9 10 11 31 50 51 52

Bloc 1 2 3 5 6 7 18 19 23 24 50Bloc-SUPER 2) 1 2 3 5 6 7 18 19 23 50

Bloc-V 8 9 10 11 50CN 25 26 27 28 29 30 31 32 33 34 35 50 51 52

1) Size II up to frame size 160; frame size 180 is size III.2) SUPER = motor with stainless steel shroud.

Design Version numberK 1) 5 18 23 50K SUPER 2) 18 2K-V 9 50 62

1) Plug in shaft.2) SUPER = motor with stainless steel shroud and stainless steel

foot with elastomer base

Design Version numberAdapta® 1) 1 2 3 18 19 23 31 51 52 53Adapta®-SUPER 2) 1 2 3 18 19 23 31 53

Bloc 4 5 18 19 32 33 51 54Bloc-SUPER 2) 4 18

CN 25 26 27 28 30 31 32 33 34 51 521) Size I.2) SUPER = motor with stainless steel shroud.

Design Version numberAdapta® 1) 1 2 3 18 19 23 31 50 51 52 53Adapta®-SUPER 2) 1 2 3 18 19 23 31 50 53

Bloc 4 5 18 19 32 33 50 51 54Bloc- SUPER 2) 4 18 50

CN 25 26 27 28 30 31 32 33 34 50 51 521) Size I.2) SUPER = motor with stainless steel shroud.

Page 29: GRUNDFOS DATA BOOKLET - Unopomp7 Euro-HYGIA® Sanitary pumps Materials Design variations See page 27. Mechanical shaft seal Grundfos offers these seal arrangements: • single seal

Designs and versions Sanitary pumps

SIPLA 12.1

SIPLA 18.1

SIPLA 28.1

SIPLA 52.1

SIPLA 65.1

SIPLA 90.1

MAXA

MAXANA

Design Version numberAdapta® 1) 1 2 3 18 19 23 31 50 51 52 53Adapta®-SUPER 2) 1 2 3 18 19 23 31 50 53

Bloc 4 5 18 19 32 33 50 51 54Bloc-SUPER 2) 4 18 50

CN 25 26 27 28 30 31 32 33 34 50 51 521) Size I.2) SUPER = motor with stainless steel shroud.

Design Version numberAdapta® 1) 1 2 3 18 19 23 31 50 51 52 53Adapta®-SUPER 2) 1 2 3 18 19 23 31 50 53

Bloc 4 5 18 19 32 33 50 51 54Bloc-SUPER 2) 4 18 50

CN 25 26 27 28 30 31 32 33 34 50 51 521) Size II.2) SUPER = motor with stainless steel shroud.

Design Version numberAdapta® 1) 1 2 3 18 19 23 31 50 51 52 53Adapta®-SUPER 2) 1 2 3 18 19 23 31 50 53

Bloc 4 5 18 19 32 33 50 51 54Bloc- SUPER 2) 4 18 50

CN 25 26 27 28 30 31 32 33 34 50 51 521) Size II.2) SUPER = motor with stainless steel shroud.

Design Version numberAdapta® 1) 1 2 3 18 19 23 31 50 51 52 53Adapta®-SUPER 2) 1 2 3 18 19 23 31 50 53

Bloc 4 5 18 19 50 54Bloc-SUPER 2) 4 18 50 54

CN 25 26 27 28 30 31 32 33 34 50 51 521) Size II.2) SUPER = motor with stainless steel shroud.

Design Version numberAdapta® 1) 22 31 51 52 53Adapta®-SUPER 2) 4 22 31

Bloc 4 5Bloc-SUPER 2) 4

CN 25 26 27 28 30 31 32 33 34 51 521) Size III.2) SUPER = motor with stainless steel shroud.

Design Version numberAdapta® 1) 22 31 51 52 53Adapta®-SUPER 2) 4 22 31

Bloc 4 5Bloc-SUPER 2) 4

CN 25 26 27 28 30 31 32 33 34 51 521) Size III.2) SUPER = motor with stainless steel shroud.

Design Version numberAdapta® 1) 1 2 22 31 50 51 52Adapta® 2) 22 31 51 52Adapta®-V 1) 8 10 31 50 51 52Adapta®-V 2) 16 31 51 52VE 31 50 57 58 59L 3) 5 6 7 21 31 50 51 52C 4) 25 26 27 28 29 30 31 32 33 34 50 51 52CN 25 26 27 28 29 30 31 32 33 34 50 51 52

1) Size II.2) Size III.3) Bearing-supported plug in shaft.4) CN with shaft sleeve.

Design Version numberAdapta® 1) 1 2 22 31 50 51 52Adapta® 2) 22 31 51 52Adapta®-SUPER 3) 8 10 31 50 51

Bloc 16 31 51 52L 4) 5 6 7 21 31 50 51 52C 5) 25 26 27 28 29 30 31 32 33 34 50 51 52CN 25 26 27 28 29 30 31 32 33 34 50 51 52

1) Size II.2) Size III.3) SUPER = motor with stainless steel shroud.4) Bearing-supported plug in shaft.5) CN with shaft sleeve.

29

Page 30: GRUNDFOS DATA BOOKLET - Unopomp7 Euro-HYGIA® Sanitary pumps Materials Design variations See page 27. Mechanical shaft seal Grundfos offers these seal arrangements: • single seal

30

Designs and versions Sanitary pumps

Version key

Housing sealing for HYGIA® pumps

Fig. 39 KLM and HPM housing sealing

* Only Euro-HYGIA®

Version number Description1 On cast iron foot2 On stainless steel foot3 Without foot/stainless steel ball feet4 On stainless steel ball feet5 On motor foot6 On motor foot with carbon steel plinth7 On motor foot with stainless steel plinth8 On stainless steel pedestal without suction elbow9 On stainless steel pedestal with suction elbow

10 Without pedestal and suction elbow 1)

11 Without pedestal but with suction elbow16 On vertical frame without suction elbow 1)

18 On stainless steel trolley, normal wheels19 On stainless steel trolley, anti-static wheels21 On pump and motor support feet (≤frame size 112)22 On Adapta® foot (≤45 kW, size III)23 On stainless steel combi foot24 Wall-mounting (Euro-HYGIA®: Only available as HPM, Contra; 3 stages are standard)25 Without base plate 2)

26 With coupling (<15 kW only with DKM spacer) 2)

27 With spacer coupling (≥ 15 kW only; <15 kW on request) 2)

28 Without coupling 2)

29 Without spacer coupling 2)

30 With motor 2)

31 Without motor 2)

32 On carbon steel base plate 2)

33 On stainless steel base plate 2)

34 Stand-proof coupling guard 2)

35 Chemical standard - base plate with anchor bolt holes 2)

50 With built-in frequency converter (tronic) - from 1.5 to 7.5 kW51 Motor with increased-safety explosion protection (EEx e II T1-T3) 3)

52 Motor with flameproof-enclosure explosion protection (EEx de IIC T1-T4) 3)

53 Hydraulic drive54 Electric motor and hydraulic drive through second shaft end57 Tank installation with base plate and discharge pipe58 Tank installation without base plate and without discharge pipe59 Tank installation with base plate and without discharge pipe60 KLM (clamp ring) - see figure below61 HPM (flange) - see figure below62 Vertical foot with fixed suction elbow

1) In connection with Adapta® size III.2) Design CN. All combinations are possible with base plate mounted. Motor and coupling size and type should be provided to determine base plate size.3) For further information on pumps conforming to the ATEX 94/9/EC Directive, contact Grundfos.

TM03

007

7 39

04, T

M03

007

8 39

04

KLM (clamp ring) HPM (flange)*

Page 31: GRUNDFOS DATA BOOKLET - Unopomp7 Euro-HYGIA® Sanitary pumps Materials Design variations See page 27. Mechanical shaft seal Grundfos offers these seal arrangements: • single seal

Sanitary pumpsPipe connections

Euro-HYGIA® I

ConnectionsDIN 32/25 32/32 40/25 40/32 40/40 50/32 50/40 50/50 65/40 65/50OD 1¼ / 1 1¼ / 1¼ 1½ / 1 1½ / 1¼ 1½ / 1½ 2 / 1¼ 2 / 1½ 2 / 2 2½ / 1½ 2½ / 2

ThreadedconnectionDIN 11851(3A0-3A1)

a1 75 75 75 75 75 75 75 75 75 75

e1 85 85 85 85 85 85 85 75 85 75

h2 170 170 170 170 170 170 170 170 170 170

e5 109 109 120 120 120 135 135 135 145 145

h3 132 132 133 133 133 148 148 148 160 160

AsepticthreadedconnectionDIN 11864-1 1)

(3A0-3A3)

a1 86 86 82 82 82 78 78 78 78 78

e1 85 85 85 85 85 85 85 75 85 75

h2 183 187 183 187 188 187 188 188 188 188

e5 105 105 108 108 108 136 136 136 146 146

h3 120 120 131 131 131 144 144 144 156 156

AsepticflangeDIN 11864-2 2)

(3A0-3A3)

a1 81 81 76 76 76 72 72 72 67 67

e1 85 85 85 85 85 85 85 75 85 75

h2 182 182 182 182 182 182 182 182 182 182

e5 112 112 122 122 122 135 135 135 142 142

h3 115 115 125 125 125 138 138 138 145 145

Clamp toDIN 32676(3A0-3A2)

a1 87 87 77 77 77 73 73 73 75 75

e1 85 85 85 85 85 85 85 75 85 75

h2 178 178 178 178 170 178 170 178 170 178

e5 113 113 123 123 123 136 136 136 150 150

h3 111 111 121 121 121 134 134 134 148 148

FlangeDIN EN 1092-1 3)

(DIN 2633/42)PN 10(3A0)

a1 75 75 75 75 75 75 75 75 75 75

e1 85 85 85 85 85 85 85 75 85 75

h2 170 170 170 170 170 170 170 170 170 170

e5 105 105 115 115 115 128 128 128 145 145

h3 103 103 113 113 113 126 126 126 143 143

Clamps forTri-Clamp®

Tri-Clover®(3A0-3A2)

a1 - - 88 - 88 - 86 86 70 70

e1 - - 85 - 85 - 85 75 85 75

h2 - - 185 - 185 - 185 185 185 185

e5 - - 123 - 123 -On request

h3 - - 121 - 121 -

Weld neckflangeDIN EN 1092-1(DIN 2633)PN 16(3A0)

a1 100 4) 100 4) 100 100 100 97 97 97 97 97

e1 85 85 85 85 85 85 85 75 85 75

h2 170 197 170 197 199 197 199 202 199 202

e5On request

h3

ThreadedconnectionDIN ISO 228(male)(3A0)

a1 85 85 81 81 81 80 80 80 - -

e1 85 85 85 85 85 85 85 75 - -

h2 170 170 170 170 170 170 170 170 - -

e5On request

- -

h3 - -

Tolerances to DIN EN 735 connection dimensions for centrifugal pumps.1) Aseptic, threaded connection for pipes to DIN 11850 row 2/3, Form A.2) Aseptic, grooved flange for pipes to DIN 11850 row 2/3, Form A.3) DNs/DNd - fixed/loose flange (DNs 65 as DIN 2642-loose flange).4) Dimensions for KLM version. For HPM version, dimension a1 is 91 mm for DNs 32.

Dimensions e5 and h3 for vertical version. Discharge branch cannot be completely drained (not eccentric).

31

Page 32: GRUNDFOS DATA BOOKLET - Unopomp7 Euro-HYGIA® Sanitary pumps Materials Design variations See page 27. Mechanical shaft seal Grundfos offers these seal arrangements: • single seal

32

Pipe connections Sanitary pumps

Euro-HYGIA® II

ConnectionsDIN 50/50 65/50 65/65 80/50 80/65 80/80 100/65 100/80 100/100 125/80 125/100OD 2 / 2 2 ½ / 2 2½ / 2½ 3 / 2 3 / 2½ 3 / 3 4 / 2½ 4 / 3 4 / 4 5 / 3 5 / 4

ThreadedconnectionDIN 11851(3A0-3A1)

a1 116 116 116 116 116 116 116 116 116 116 116

e1 98 98 98 98 98 85.5 98 85.5 85.5 85.5 85.5

h2 200 200 200 200 200 200 200 200 200 200 200

e5 135 145 145 175 175 175 190 190 190 - -

h3 148 160 160 190 190 190 209 209 209 - -

AsepticthreadedconnectionDIN 11864-1 1)

(3A0-3A3)

a1 112 119 119 125 125 125 133 133 133 - -

e1 98 98 98 98 98 85.5 98 85.5 85.5 - -

h2 206 206 213 206 213 220 213 220 227 - -

e5 136 146 146 175 175 175 191 191 191 - -

h3 144 156 156 187 187 187 205 205 205 - -

AsepticflangeDIN 11864-2 2)

(3A0-3A3)

a1 106.5 108.5 108.5 110.5 110.5 110.5 110.5 110.5 110.5 - -

e1 98 98 98 98 98 85.5 98 85.5 85.5 - -

h2 200.5 200.5 202.5 200.5 202.5 205.5 202.5 205.5 204.5 - -

e5 135.5 142.5 142.5 169.5 169.5 169.5 179.5 179.5 179.5 - -

h3 138.5 145.5 145.5 172.5 172.5 172.5 182.5 182.5 182.5 - -

Clamp toDIN 32676(3A0-3A2)

a1 102.5 111 111 111 111 111 111 111 111 - -

e1 98 98 98 98 98 85.5 98 85.5 85.5 - -

h2 209 209 228 209 228 206 228 206 205 - -

e5 136.5 150 150 175 175 175 185 185 185 - -

h3 134.5 148 148 173 173 173 183 183 183 - -

FlangeDIN EN 1092-1 3)

(DIN 2633/42)PN 10(3A0)

a1 116 116 116 116 116 116 116 116 116 116 116

e1 98 98 98 98 98 85.5 98 85.5 85.5 85.5 85.5

h2 200 200 200 200 200 200 200 200 200 200 200

e5 128 145 145 170 170 170 185 185 185 - -

h3 126 143 143 168 168 168 183 183 183 - -

Clamps forTri-Clamp®

Tri-Clover®(3A0-3A2)

a1 109.6 109.6 109.6 111.6 111.6 111.6 111.6 111.6 111.6 - -

e1 98 98 98 98 98 98 98 98 85.5 - -

h2 215.6 215.6 215.6 215.6 215.6 225 215.6 225 215.6 - -

e5On request

- -

h3 - -

Weld neckflangeDIN EN 1092-1(DIN 2633)PN 16(3A0)

a1 126 128 128 133 133 133 135 135 135 - -

e1 98 98 98 98 98 85.5 98 85.5 85.5 - -

h2 232 232 234 232 234 228 234 228 229 - -

e5On request

- -

h3 - -

FlangeAPV FN1/FG1PN 10(3A0-3A1)

a1 105 107 107 107 107 107 107 107 107 145 145

e1 98 98 98 98 98 85.5 98 85.5 85.5 85.5 85.5

h2 199 199 224 199 224 200 224 200 200 200 200

e5On request

- -

h3 - -

Tolerances to DIN EN 735 connection dimensions for centrifugal pumps.1) Aseptic, threaded connection for pipes to DIN 11850, row 2/3, Form A.2) Aseptic, grooved flange for pipes to DIN 11850, row 2/3, Form A.3) DNs/DNd - fixed/loose flange (DNs 1255 as DIN 2642 loose flange. Attention! This type of connection cannot

be used for Bloc-SUPER with frame size 160. Use weld neck flange to DIN 2633.Dimensions e5 and h3 for vertical version. Discharge branch cannot be completely drained (not eccentric).

Page 33: GRUNDFOS DATA BOOKLET - Unopomp7 Euro-HYGIA® Sanitary pumps Materials Design variations See page 27. Mechanical shaft seal Grundfos offers these seal arrangements: • single seal

Pipe connections Sanitary pumps

F&B-HYGIA® I

F&B-HYGIA® II

ConnectionsDIN 40/40 50/50OD 1½ / 1½ 2 / 2

ThreadedconnectionDIN 11851(3A0-3A1)

a1 75 75

e1 85 75

h2 170 170

Clamps forTri-Clamp®

Tri-Clover®(3A0-3A2)

a1 79 75

e1 85 75

h2 185 185

ConnectionsDIN 65/65 80/80 100/100OD 2½ / 2½ 3 / 3 4 / 4

ThreadedconnectionDIN 11851(3A0-3A1)

a1 116 116 116

e1 98 85,5 85,5

h2 200 200 200

Clamps forTri-Clamp®

Tri-Clover®(3A0-3A2)

a1 111,5 111,5 111,5

e1 98 85,5 85,5

h2 215,5 206,5 205,5

Tolerances to DIN EN 735 connection dimensions for centrifugal pumps.

33

Page 34: GRUNDFOS DATA BOOKLET - Unopomp7 Euro-HYGIA® Sanitary pumps Materials Design variations See page 27. Mechanical shaft seal Grundfos offers these seal arrangements: • single seal

34

Pipe connections Sanitary pumps

Contra I

ConnectionsDIN 25/25 32/25 32/32 40/32 40/40 25/25 32/25 32/32 40/32 40/40OD 1 / 1 1¼ / 1 1¼ / 1¼ 1½ / 1¼ 1½ / 1½ 1 / 1 1¼ / 1 1¼ / 1¼ 1½ / 1¼ 1½ / 1½

1-Stage 2-Stage

ThreadedconnectionDIN 11851(3A0-3A1)

a1 117 120 123 124 127 143 146 149 150 153

f2 1 1 4 4 7 1 1 4 4 7

h2 160 160 160 160 160 160 160 160 160 160

e5 106 109 109 120 120 106 109 109 120 120

h3 119 122 122 133 133 119 122 122 133 133

AsepticthreadedconnectionDIN 11864-1 1)

(3A0-3A3)

a1 114 118 121 122 125 140 144 147 149 151

f2 1 1 4 4 7 1 1 4 4 7

h2 157 157 158 158 158 157 157 158 158 158

e5 106 105 105 108 108 106 105 105 108 108

h3 116 120 120 131 131 116 120 120 131 131

AsepticflangeDIN 11864-2 2)

(3A0-3A3)

a1 113.5 113.6 116.5 116.6 119.5 139.5 139.5 142.5 142.5 145.5

f2 1 1 4 4 7 1 1 4 4 7

h2 156.5 156.5 153.5 153.5 152.5 156.5 156.5 153.5 153.5 152.5

e5 112 112 112 122 122 112 112 112 122 122

h3 115 115 115 125 125 115 115 115 125 125

Clamp toDIN 32676(3A0-3A2)

a1 109.5 109.5 112.5 112.5 115.5 135.5 135.5 138.5 138.5 141.5

f2 1 1 4 4 7 1 1 4 4 7

h2 152.5 152.5 149.5 149.5 148.5 152.5 152.5 149.5 149.5 148.5

e5 113 113 113 123 123 113 113 113 123 123

h3 111 111 111 121 121 111 111 111 121 121

FlangeDIN EN 1092-1 3)

(DIN 2642)PN 10(3A0)

a1 101 101 104 104 107 127 127 130 130 133

f2 1 1 4 4 7 1 1 4 4 7

h2 144 144 141 141 140 144 144 141 141 140

e5 105 105 105 115 115 105 105 105 115 115

h3 103 103 103 113 113 103 103 103 113 113

Clamps forTri-Clamp®

Tri-Clover®(3A0-3A2)

a1 116.6 - - - 125 142.6 - - - 151

f2 1 - - - 7 1 - - - 7

h2 160 - - - 158 160 - - - 158

e5 95 - - - 123 95 - - - 123

h3 93 - - - 121 93 - - - 121

Weld neckflangeDIN EN 1092-1(DIN 2633)PN 16(3A0)

a1 117 121 124 133 136 143 147 150 159 162

f2 1 1 4 4 7 1 1 4 4 7

h2 160 160 160 160 169 160 160 160 160 169

e5On request On request

h3

ThreadedconnectionDIN ISO 228(male)(3A0)

a1 113 113 116 121 124 139 139 142 147 150

f2 1 1 4 4 7 1 1 4 4 7

h2 156 156 153 153 157 156 156 153 153 157

e5On request On request

h3

Tolerances to DIN EN 735 connection dimensions for centrifugal pumps.1) Aseptic, threaded connection for pipes to DIN 11850 row 2/3, Form A.2) Aseptic, grooved flange for pipes to DIN 11850 row 2/3, Form A.3) DNs/DNd - loose flange

Dimensions e5 and h3 for vertical version. Discharge branch can be completely drained (eccentric).

Page 35: GRUNDFOS DATA BOOKLET - Unopomp7 Euro-HYGIA® Sanitary pumps Materials Design variations See page 27. Mechanical shaft seal Grundfos offers these seal arrangements: • single seal

Pipe connections Sanitary pumps

Contra I, continued

ConnectionsDIN 25/25 32/25 32/32 40/32 40/40 25/25 32/25 32/32 40/32 40/40OD 1 / 1 1¼ / 1 1¼ / 1¼ 1½ / 1¼ 1½ / 1½ 1 / 1 1¼ / 1 1¼ / 1¼ 1½ / 1¼ 1½ / 1½

3-Stage 4-Stage

ThreadedconnectionDIN 11851(3A0-3A1)

a1 169 172 175 176 179 195 198 201 202 205

f2 1 1 4 4 7 1 1 4 4 7

h2 160 160 160 160 160 160 160 160 160 160

e5 106 109 109 120 120 106 109 109 120 120

h3 119 122 122 133 133 119 122 122 133 133

AsepticthreadedconnectionDIN 11864-1 1)

(3A0-3A3)

a1 166 170 173 174 177 192 196 199 201 203

f2 1 1 4 4 7 1 1 4 4 7

h2 157 157 158 158 158 157 157 158 158 158

e5 106 105 105 108 108 106 105 105 108 108

h3 116 120 120 131 131 116 120 120 131 131

AsepticflangeDIN 11864-2 2)

(3A0-3A3)

a1 165.5 165.5 168.5 168.5 171.5 191.5 191.5 194.5 194.5 197.5

f2 1 1 4 4 7 1 1 4 4 7

h2 156.5 156.5 153.5 153.5 152.5 156.5 156.5 153.5 153.5 152.5

e5 112 112 112 122 122 112 112 112 122 122

h3 115 115 115 125 125 115 115 115 125 125

Clamp toDIN 32676(3A0-3A2)

a1 161.5 161.5 164.5 164.5 167.5 187.5 187.5 190.5 190.5 193.5

f2 1 1 4 4 7 1 1 4 4 7

h2 152.5 152.5 149.5 149.5 148.5 152.5 152.5 149.5 149.5 148.5

e5 113 113 113 123 123 113 113 113 123 123

h3 111 111 111 121 121 111 111 111 121 121

FlangeDIN EN 1092-1 3)

(DIN 2642)PN 10(3A0)

a1 153 153 156 156 159 179 179 182 182 185

f2 1 1 4 4 7 1 1 4 4 7

h2 144 144 141 141 140 144 144 141 141 140

e5 105 105 105 115 115 105 105 105 115 115

h3 103 103 103 113 113 103 103 103 113 113

Clamps forTri-Clamp®

Tri-Clover®(3A0-3A2)

a1 168.6 - - - 177 194.6 - - - 203

f2 1 - - - 7 1 - - - 7

h2 160 - - - 158 160 - - - 158

e5 95 - - - 123 95 - - - 123

h3 93 - - - 121 93 - - - 121

Weld neckflangeDIN EN 1092-1(DIN 2633)PN 16(3A0)

a1 169 173 176 185 188 195 199 202 211 214

f2 1 1 4 4 7 1 1 4 4 7

h2 160 160 160 160 169 160 160 160 160 169

e5On request On request

h3

ThreadedconnectionDIN ISO 228(male)(3A0)

a1 165 165 168 173 176 191 191 194 199 202

f2 1 1 4 4 7 1 1 4 4 7

h2 156 156 153 153 157 156 156 153 153 157

e5On request On request

h3

Tolerances to DIN EN 735 connection dimensions for centrifugal pumps.1) Aseptic, threaded connection for pipes to DIN 11850 row 2/3, Form A.2) Aseptic, grooved flange for pipes to DIN 11850 row 2/3, Form A.3) DNs/DNd - loose flange

Dimensions e5 and h3 for vertical version. Discharge branch can be completely drained (eccentric).

35

Page 36: GRUNDFOS DATA BOOKLET - Unopomp7 Euro-HYGIA® Sanitary pumps Materials Design variations See page 27. Mechanical shaft seal Grundfos offers these seal arrangements: • single seal

36

Pipe connections Sanitary pumps

Contra I, continued

ConnectionsDIN 25/25 32/25 32/32 40/32 40/40 25/25 32/25 32/32 40/32 40/40OD 1 / 1 1¼ / 1 1¼ / 1¼ 1½ / 1¼ 1½ / 1½ 1 / 1 1¼ / 1 1¼ / 1¼ 1½ / 1¼ 1½ / 1½

5-Stage 6-Stage

ThreadedconnectionDIN 11851(3A0-3A1)

a1 221 224 227 228 231 247 250 253 254 257

f2 1 1 4 4 7 1 1 4 4 7

h2 160 160 160 160 160 160 160 160 160 160

e5 106 109 109 120 120 106 109 109 120 120

h3 119 122 122 133 133 119 122 122 133 133

AsepticthreadedconnectionDIN 11864-1 1)

(3A0-3A3)

a1 218 222 225 226 229 244 248 251 253 255

f2 1 1 4 4 7 1 1 4 4 7

h2 157 157 158 158 158 157 157 158 158 158

e5 106 105 105 108 108 106 105 105 108 108

h3 116 120 120 131 131 116 120 120 131 131

AsepticflangeDIN 11864-2 2)

(3A0-3A3)

a1 217.5 217.5 220.5 220.5 223.5 243.5 243.5 246.5 246.5 249.5

f2 1 1 4 4 7 1 1 4 4 7

h2 156.5 156.5 153.5 153.5 152.5 156.5 156.5 153.5 153.5 152.5

e5 112 112 112 122 122 112 112 112 122 122

h3 115 115 115 125 125 115 115 115 125 125

Clamp toDIN 32676(3A0-3A2)

a1 213.5 213.5 216.5 216.5 219.5 239.5 239.5 242.5 242.5 245.5

f2 1 1 4 4 7 1 1 4 4 7

h2 152.5 152.5 149.5 149.5 148.5 152.5 152.5 149.5 149.5 148.5

e5 113 113 113 123 123 113 113 113 123 123

h3 111 111 111 121 121 111 111 111 121 121

FlangeDIN EN 1092-1 3)

(DIN 2642)PN 10(3A0)

a1 205 205 209 209 211 231 231 234 234 237

f2 1 1 4 4 7 1 1 4 4 7

h2 144 144 141 141 140 144 144 141 141 140

e5 105 105 105 115 115 105 105 105 115 115

h3 103 103 103 113 113 103 103 103 113 113

Clamps forTri-Clamp®

Tri-Clover®(3A0-3A2)

a1 220.6 - - - 229 246.6 - - - 255

f2 1 - - - 7 1 - - - 7

h2 160 - - - 158 160 - - - 158

e5 95 - - - 123 95 - - - 123

h3 93 - - - 121 93 - - - 121

Weld neckflangeDIN EN 1092-1(DIN 2633)PN 16(3A0)

a1 221 225 228 237 240 247 251 254 263 266

f2 1 1 4 4 7 1 1 4 4 7

h2 160 160 160 160 169 160 160 160 160 169

e5On request On request

h3

ThreadedconnectionDIN ISO 228(male)(3A0)

a1 217 217 220 225 228 243 243 246 251 254

f2 1 1 4 4 7 1 1 4 4 7

h2 156 156 153 153 157 156 156 153 153 157

e5On request On request

h3

Tolerances to DIN EN 735 connection dimensions for centrifugal pumps.1) Aseptic, threaded connection for pipes to DIN 11850 row 2/3, Form A.2) Aseptic, grooved flange for pipes to DIN 11850 row 2/3, Form A.3) DNs/DNd - loose flange

Dimensions e5 and h3 for vertical version. Discharge branch can be completely drained (eccentric).

Page 37: GRUNDFOS DATA BOOKLET - Unopomp7 Euro-HYGIA® Sanitary pumps Materials Design variations See page 27. Mechanical shaft seal Grundfos offers these seal arrangements: • single seal

Pipe connections Sanitary pumps

Contra II

ConnectionsDIN 50/40 50/50 65/50 65/65 80/65 50/40 50/50 65/50 65/65 80/65OD 2 / 1½ 2 / 2 2½ / 2 2½ / 2½ 3 / 2½ 2 / 1½ 2 / 2 2½ / 2 2½ / 2½ 3 / 2½

1-Stage 2-Stage

ThreadedconnectionDIN 11851(3A0-3A1)

a1 124 127 132 140 145 156 159 164 172 177

f2 0 3 3 11 11 0 3 3 11 11

h2 205 205 205 205 205 205 205 205 205 205

e5 135 135 145 145 175 135 135 145 145 175

h3 148 148 160 160 190 148 148 160 160 190

AsepticthreadedconnectionDIN 11864-1 1)

(3A0-3A3)

a1 120 123 128 136 142 152 155 160 168 174

f2 0 3 3 11 11 0 3 3 11 11

h2 203 201 201 201 201 203 201 201 201 201

e5 136 136 146 146 175 136 136 146 146 175

h3 144 144 156 156 187 144 144 156 156 187

AsepticflangeDIN 11864-2 2)

(3A0-3A3)

a1 113 116 117 125 127 145 148 149 157 159

f2 0 3 3 11 11 0 3 3 11 11

h2 198 196 196 191 191 198 196 196 191 191

e5 135.5 135.5 142.5 142.5 169.5 135.5 135.5 142.5 142.5 169.5

h3 138.5 138.5 145.5 145.5 172.5 138.5 138.5 145.5 14.5 172.5

Clamp toDIN 32676(3A0-3A2)

a1 110 113 120 128 128 142 145 152 160 160

f2 0 3 3 11 11 0 3 3 11 11

h2 194 192 192 193 193 194 192 192 193 193

e5 136.5 136.5 150 150 175 136.5 136.5 150 150 175

h3 134.5 134.5 148 148 173 134.5 134.5 148 148 173

FlangeDIN EN 1092-1 3)

(DIN 2642)PN 10(3A0)

a1 102 105 115 123 122 134 137 147 155 154

f2 0 3 3 11 11 0 3 3 11 11

h2 185 183 183 188 188 185 183 183 188 188

e5 128 128 145 145 170 128 128 145 145 170

h3 126 126 143 143 168 126 126 143 143 168

Clamps forTri-Clamp®

Tri-Clover®(3A0-3A2)

a1 146 149 151.8 159.8 - 178 181 183.8 191.8 -

f2 0 3 3 11 11 0 3 3 11 11

h2 201 199 199 194 194 201 199 199 194 194

e5On request On request

h3

Weld neckflangeDIN EN 1092-1(DIN 2633)PN 16(3A0)

a1 134 137 137 145 - 166 169 169 177 -

f2 0 3 3 11 - 0 3 3 11 -

h2 214 215 215 210 - 214 215 215 210 -

e5On request On request

h3

AVP-FG1ThreadedconnectionDIN ISO 228(male)(3A0)

a1 113 116 116 124 - 145 148 148 156 -

f2 0 3 3 11 - 0 3 3 11 -

h2 - 194 194 189 - - 194 194 189 -

e5On request On request

h3

Tolerances to DIN EN 735 connection dimensions for centrifugal pumps.1) Aseptic, threaded connection for pipes to DIN 11850 row 2/3, Form A.2) Aseptic, grooved flange for pipes to DIN 11850 row 2/3, Form A.3) DNs/DNd - loose flange

Dimensions e5 and h3 for vertical version. Discharge branch can be completely drained (eccentric).

37

Page 38: GRUNDFOS DATA BOOKLET - Unopomp7 Euro-HYGIA® Sanitary pumps Materials Design variations See page 27. Mechanical shaft seal Grundfos offers these seal arrangements: • single seal

38

Pipe connections Sanitary pumps

Contra II, continued

ConnectionsDIN 50/40 50/50 65/50 65/65 80/65 50/40 50/50 65/50 65/65 80/65OD 2 / 1½ 2 / 2 2½ / 2 2½ / 2½ 3 / 2½ 2 / 1½ 2 / 2 2½ / 2 2½ / 2½ 3 / 2½

3-Stage 4-Stage

ThreadedconnectionDIN 11851(3A0-3A1)

a1 188 191 196 204 209 220 223 228 236 241

f2 0 3 3 11 11 0 3 3 11 11

h2 205 205 205 205 205 205 205 205 205 205

e5 135 135 145 145 175 135 135 145 145 175

h3 148 148 160 160 190 148 148 160 160 190

AsepticthreadedconnectionDIN 11864-1 1)

(3A0-3A3)

a1 184 187 192 200 206 216 219 224 232 238

f2 0 3 3 11 11 0 3 3 11 11

h2 203 201 201 201 201 203 201 201 201 201

e5 136 136 146 146 175 136 136 146 146 175

h3 144 144 156 156 187 144 144 156 156 187

AsepticflangeDIN 11864-2 2)

(3A0-3A3)

a1 177 180 181 189 191 209 212 213 221 223

f2 0 3 3 11 11 0 3 3 11 11

h2 198 196 196 191 191 198 196 196 191 191

e5 135.5 135.5 142.5 142.5 169.5 135.5 135.5 142.5 142.5 169.5

h3 138.5 138.5 145.5 14.5 172.5 138.5 138.5 145.5 14.5 172.5

Clamp toDIN 32676(3A0-3A2)

a1 174 177 184 192 192 206 209 216 224 224

f2 0 3 3 11 11 0 3 3 11 11

h2 194 192 192 193 193 194 192 192 193 193

e5 136.5 136.5 150 150 175 136.5 136.5 150 150 175

h3 134.5 134.5 148 148 173 134.5 134.5 148 148 173

FlangeDIN EN 1092-1 3)

(DIN 2642)PN 10(3A0)

a1 166 169 179 187 186 198 201 211 219 218

f2 0 3 3 11 11 0 3 3 11 11

h2 185 183 183 188 188 185 183 183 188 188

e5 128 128 145 145 170 128 128 145 145 170

h3 126 126 143 143 168 126 126 143 143 168

Clamps forTri-Clamp®

Tri-Clover®(3A0-3A2)

a1 210 213 215.8 223.8 - 242 245 247.8 255.8 -

f2 0 3 3 11 11 0 3 3 11 11

h2 201 199 199 194 194 201 199 199 194 194

e5On request On request

h3

Weld neckflangeDIN EN 1092-1(DIN 2633)PN 16(3A0)

a1 198 201 201 209 - 230 233 233 241 -

f2 0 3 3 11 - 0 3 3 11 -

h2 214 215 215 210 - 214 215 215 210 -

e5On request On request

h3

AVP-FG1ThreadedconnectionDIN ISO 228(male)(3A0)

a1 177 180 180 188 - 209 212 212 220 -

f2 0 3 3 11 - 0 3 3 11 -

h2 - 194 194 189 - - 194 194 189 -

e5On request On request

h3

Tolerances to DIN EN 735 connection dimensions for centrifugal pumps.1) Aseptic, threaded connection for pipes to DIN 11850 row 2/3, Form A.2) Aseptic, grooved flange for pipes to DIN 11850 row 2/3, Form A.3) DNs/DNd - loose flange

Dimensions e5 and h3 for vertical version. Discharge branch can be completely drained (eccentric).

Page 39: GRUNDFOS DATA BOOKLET - Unopomp7 Euro-HYGIA® Sanitary pumps Materials Design variations See page 27. Mechanical shaft seal Grundfos offers these seal arrangements: • single seal

Pipe connections Sanitary pumps

Contra II, continued

ConnectionsDIN 50/40 50/50 65/50 65/65 80/65OD 2 / 1½ 2 / 2 2½ / 2 2½ / 2½ 3 / 2½

5-Stage

ThreadedconnectionDIN 11851(3A0-3A1)

a1 252 255 260 268 273

f2 0 3 3 11 11

h2 205 205 205 205 205

e5 135 135 145 145 175

h3 148 148 160 160 190

AsepticthreadedconnectionDIN 11864-1 1)

(3A0-3A3)

a1 248 251 256 264 270

f2 0 3 3 11 11

h2 203 201 201 201 201

e5 136 136 146 146 175

h3 144 144 156 156 187

AsepticflangeDIN 11864-2 2)

(3A0-3A3)

a1 241 244 245 253 255

f2 0 3 3 11 11

h2 198 196 196 191 191

e5 135.5 135.5 142.5 142.5 169.5

h3 138.5 138.5 145.5 14.5 172.5

Clamp toDIN 32676(3A0-3A2)

a1 238 241 248 256 256

f2 0 3 3 11 11

h2 194 192 192 193 193

e5 136.5 136.5 150 150 175

h3 134.5 134.5 148 148 173

FlangeDIN EN 1092-1 3)

(DIN 2642)PN 10(3A0)

a1 230 233 243 251 250

f2 0 3 3 11 11

h2 185 183 183 188 188

e5 128 128 145 145 170

h3 126 126 143 143 168

Clamps forTri-Clamp®

Tri-Clover®(3A0-3A2)

a1 274 277 279.8 287.8 -

f2 0 3 3 11 11

h2 201 199 199 194 194

e5On request

h3

Weld neckflangeDIN EN 1092-1(DIN 2633)PN 16(3A0)

a1 262 265 265 273 -

f2 0 3 3 11 -

h2 214 215 215 210 -

e5On request

h3

AVP-FG1ThreadedconnectionDIN ISO 228(male)(3A0)

a1 241 244 244 252 -

f2 0 3 3 11 -

h2 - 194 194 189 -

e5On request

h3

ConnectionsDIN 50/40 50/50 65/50 65/65 80/65OD 2 / 1½ 2 / 2 2½ / 2 2½ / 2½ 3 / 2½

5-Stage

Tolerances to DIN EN 735 connection dimensions for centrifugal pumps.1) Aseptic, threaded connection for pipes to DIN 11850 row 2/3, Form A.2) Aseptic, grooved flange for pipes to DIN 11850 row 2/3, Form A.3) DNs/DNd - loose flange

Dimensions e5 and h3 for vertical version. Discharge branch can be completely drained (eccentric).

39

Page 40: GRUNDFOS DATA BOOKLET - Unopomp7 Euro-HYGIA® Sanitary pumps Materials Design variations See page 27. Mechanical shaft seal Grundfos offers these seal arrangements: • single seal

40

Pipe connections Sanitary pumps

durietta 0

ConnectionsDIN 25/25 32/25 32/32 40/32 40/40 25/25 32/25 32/32 40/32 40/40OD 1 / 1 1¼ / 1 1¼ / 1¼ 1½ / 1¼ 1½ / 1½ 1 / 1 1¼ / 1 1¼ / 1¼ 1½ / 1¼ 1½ / 1½

1-Stage 2-Stage

ThreadedconnectionDIN 11851(3A0-3A1)

A 44 50 50 52 52 65 71 71 73 73A' 44 47 47 - - 44 47 47 - -

B(1) 47 47 47 47 47 47 47 47 47 47

B'(2) 43 43 43 43 43 43 43 43 43 43

C 110 110 130 130 130 110 100 130 130 130J 110 98 98 - - 110 98 98 - - K 50 50 50 50 50 71 71 71 71 71

ThreadedconnectionSMS(3A0-3A1)

A 52 42 42 - - 73 63 63 - - A' 42 49 49 - - 42 49 49 - -

B(1) 47 47 47 - - 47 47 47 - -

B'(2) 43 43 43 - - 43 43 43 - -

C 110 110 135 - - 110 110 135 - - J 110 98 98 - - 110 98 98 - - K 50 50 50 - - 71 71 71 - -

Clamp toSMS(3A0-3A1)

A 63 63 63 - - 84 84 84 - - A' 42 49 49 - - 42 49 49 - -

B(1) 47 47 47 - - 47 47 47 - -

B'(2) 43 43 43 - - 43 43 43 - -

C 110 110 130 - - 110 130 130 - - J 110 98 98 - - 110 98 98 - - K 50 50 50 - - 71 71 71 - -

Clamp toISO(3A0-3A1)

A 63 63 63 - - 84 84 84 - - A' 47 49 49 - - 47 49 49 - -

B(1) 47 47 47 - - 47 47 47 - -

B'(2) 43 43 43 - - 43 43 43 - -

C 110 110 130 - - 110 110 130 - - J 110 98 98 - - 110 98 98 - - K 50 50 50 - - 71 71 71 - -

FlangeDIN EN 1092-1 3)

(DIN 2642)PN 10(3A0)

A 78 78 78 78 - 99 99 99 99 - A' 91 100 100 / - 91 100 100 / -

B(1) 47 47 47 47 - 47 47 47 47 -

B'(2) 43 43 43 43 - 43 43 43 43 -

C 107 107 135 135 - 107 107 135 135 - J 130 120 120 - - 130 120 120 - - K 50 50 50 50 - 71 71 71 71 -

ThreadedconnectionDIN ISO 228(male) - GAZ(3A0)

A 52 52 52 57 57 73 73 73 78 78A' 45 49 49 - - 45 49 49 - -

B(1) 47 47 47 47 47 47 47 47 47 47

B'(2) 43 43 43 43 43 43 43 43 43 43

C 130 130 155 155 136 130 130 155 155 136J 115 105 105 - - 115 105 105 - - K 50 50 50 50 50 71 71 71 71 71

TappedconnectionDIN 2999(female)(3A0)

A - 42 - - - - 63 - - - A' - 49 - - - - 49 - - -

B(1) - 47 - - - - 47 - - -

B'(2) - 43 - - - - 43 - - -

C - 120 - - - - 120 - - - J - 116 - - - - 116 - - - K - 50 - - - - 71 - - -

Tolerances to DIN EN 735 connection dimensions for centrifugal pumps.(1) (2) Add 37.5 mm for pumps with double mechanical seal.3) DNs/DNd - loose flange

Page 41: GRUNDFOS DATA BOOKLET - Unopomp7 Euro-HYGIA® Sanitary pumps Materials Design variations See page 27. Mechanical shaft seal Grundfos offers these seal arrangements: • single seal

Pipe connections Sanitary pumps

durietta 0, continued

ConnectionsDIN 25/25 32/25 32/32 40/32 40/40 25/25 32/25 32/32 40/32 40/40OD 1 / 1 1¼ / 1 1¼ / 1¼ 1½ / 1¼ 1½ / 1½ 1 / 1 1¼ / 1 1¼ / 1¼ 1½ / 1¼ 1½ / 1½

3-Stage 4-Stage

ThreadedconnectionDIN 11851(3A0-3A1)

A 85 91 91 93 93 106 112 112 114 114A' 44 47 47 - - 44 47 47 - -

B(1) 67 67 67 67 67 67 67 67 67 67

B'(2) 62 62 62 62 62 62 62 62 62 62

C 110 110 130 130 130 110 110 130 130 130J 110 98 98 - - 110 98 98 - - K 91 91 91 91 91 112 112 112 112 112

ThreadedconnectionSMS(3A0-3A1)

A 93 83 83 - - 114 104 104 - - A' 42 49 49 - - 42 49 49 - -

B(1) 67 67 67 - - 67 67 67 - -

B'(2) 62 62 62 - - 62 62 62 - -

C 110 110 135 - - 110 110 135 - - J 110 98 98 - - 110 98 98 - - K 91 91 91 - - 112 112 112 - -

Clamp toSMS(3A0-3A1)

A 104 104 104 - - 125 125 125 - - A' 42 49 49 - - 42 49 49 - -

B(1) 67 67 67 - - 67 67 67 - -

B'(2) 62 62 62 - - 62 62 62 - -

C 110 110 130 - - 110 110 130 - - J 110 98 98 - - 110 98 98 - - K 91 91 91 - - 112 112 112 - -

Clamp toISO(3A0-3A1)

A 104 104 104 - - 125 125 125 - - A' 42 49 49 - - 47 49 49 - -

B(1) 67 67 67 - - 67 67 67 - -

B'(2) 62 62 62 - - 62 62 62 - -

C 110 110 130 - - 110 130 130 - - J 110 98 98 - - 110 98 98 - - K 91 91 91 - - 112 112 112 - -

FlangeDIN EN 1092-1 3)

(DIN 2642)PN 10(3A0)

A 119 119 119 119 - 140 140 140 140 - A' 91 100 100 - - 91 100 100 - -

B(1) 67 67 67 - - 67 67 67 67 -

B'(2) 62 62 62 - - 62 62 62 62 -

C 107 107 135 135 - 107 107 135 135 - J 130 120 120 - - 130 120 120 - - K 91 91 91 91 - 112 112 112 112 112

ThreadedconnectionDIN ISO 228(male) - GAZ(3A0)

A 93 93 93 98 98 114 114 114 119 119A' 45 49 49 - - 45 49 49 - -

B(1) 67 67 67 67 67 67 67 67 67 67

B'(2) 62 62 62 62 62 62 62 62 62 62

C 130 130 155 155 136 130 130 155 155 136J 15 105 105 - - 115 105 105 - - K 91 91 91 91 91 112 112 112 112 -

TappedconnectionDIN 2999(female)(3A0)

A - 83 - - - - 104 - - - A' - 49 - - - - 49 - - -

B(1) - 67 - - - - 67 - - -

B'(2) - 62 - - - - 62 - - -

C - 120 - - - - 120 - - - J - 116 - - - - 116 - - - K - 91 - - - - 112 - - -

Tolerances to DIN EN 735 connection dimensions for centrifugal pumps.(1) (2) Add 37.5 mm for pumps with double mechanical seal.3) DNs/DNd - loose flange

41

Page 42: GRUNDFOS DATA BOOKLET - Unopomp7 Euro-HYGIA® Sanitary pumps Materials Design variations See page 27. Mechanical shaft seal Grundfos offers these seal arrangements: • single seal

42

Pipe connections Sanitary pumps

durietta 0, continued

ConnectionsDIN 25/25 32/25 32/32 40/32 40/40 25/25 32/25 32/32 40/32 40/40OD 1 / 1 1¼ / 1 1¼ / 1¼ 1½ / 1¼ 1½ / 1½ 1 / 1 1¼ / 1 1¼ / 1¼ 1½ / 1¼ 1½ / 1½

5-Stage 6-Stage

ThreadedconnectionDIN 11851(3A0-3A1)

A 126 132 132 134 134 14 153 153 155 155A' 44 47 47 - - 44 47 47 - -

B(1) 67 67 67 67 67 67 67 67 67 67

B'(2) 62 62 62 62 62 62 62 62 62 62

C 110 110 130 130 130 110 110 130 130 130J 110 98 98 - - 110 98 98 - - K 132 132 132 132 132 153 153 153 153 153

ThreadedconnectionSMS(3A0-3A1)

A 134 124 124 - - 155 145 145 - - A' 42 49 49 - - 42 49 49 - -

B(1) 67 67 67 - - 67 67 67 - -

B'(2) 62 62 62 - - 62 62 62 - -

C 110 110 135 - - 110 110 135 - - J 110 98 98 - - 110 98 98 - - K 132 132 132 - - 153 153 153 - -

Clamp toSMS(3A0-3A1)

A 145 145 145 - - 166 166 166 - - A' 47 49 49 - - 42 49 49 - -

B(1) 67 67 67 - - 67 67 67 - -

B'(2) 62 62 62 - - 62 62 62 - -

C 110 110 130 - - 110 110 130 - - J 110 98 98 - - 110 98 98 - - K 132 132 132 - - 153 153 153 - -

Clamp toISO(3A0-3A1)

A 145 145 145 - - 166 166 166 - - A' 47 49 49 - - 47 49 49 - -

B(1) 67 67 67 - - 67 67 67 - -

B'(2) 62 62 62 - - 62 62 62 - -

C 110 130 130 - - 110 110 130 - - J 110 98 98 - - 110 98 98 - - K 132 132 132 - - 153 153 153 - -

FlangeDIN EN 1092-1 3)

(DIN 2642)PN 10(3A0)

A 160 160 160 160 - 181 181 181 181 - A' 91 100 100 - - 91 100 100 - -

B(1) 67 67 67 67 - 67 67 67 67 -

B'(2) 62 62 62 62 - 62 62 62 62 -

C 107 107 135 135 - 107 107 135 135 - J 130 120 120 - - 130 120 120 - - K 132 132 132 132 - 153 153 153 153 -

ThreadedconnectionDIN ISO 228(male) - GAZ(3A0)

A 134 134 134 139 139 155 155 155 160 160A' 45 49 49 - - 45 49 49 - -

B(1) 67 67 67 67 67 67 67 67 67 67

B'(2) 62 62 62 62 62 62 62 62 62 62

C 130 130 155 155 136 130 130 155 155 136J 115 105 105 - - 115 105 105 - - K 132 132 132 132 - 153 153 153 153 153

TappedconnectionDIN 2999(female)(3A0)

A - 124 - - - - 145 - - - A' - 49 - - - - 49 - - -

B(1) - 67 - - - - 67 - - -

B'(2) - 62 - - - - 62 - - -

C - 120 - - - - 120 - - - J - 116 - - - - 116 - - - K - 132 - - - - 153 - - -

Tolerances to DIN EN 735 connection dimensions for centrifugal pumps.(1) (2) Add 37.5 mm for pumps with double mechanical seal.3) DNs/DNd - loose flange

Page 43: GRUNDFOS DATA BOOKLET - Unopomp7 Euro-HYGIA® Sanitary pumps Materials Design variations See page 27. Mechanical shaft seal Grundfos offers these seal arrangements: • single seal

Pipe connections Sanitary pumps

MAXAMAXA, frame size 80-160

MAXA, frame size 80-200

MAXA, frame size 80-250

MAXA, frame size 80-315

MAXA, frame size 100-200

MAXA, frame size 100-250

MAXA, frame size 125-250

MAXA, frame size 100-315

MAXA, frame size 125-315

MAXA, frame size 150-250

MAXA, frame size 150-315

MAXA, frame size 150-400

MAXA, frame size 200-400

ConnectionsDIN 100/80 125/80 125/100 150/80OD 4 / 3 5 / 3 5 / 4 6 / 3

Kremo-flangeDIN EN 1092-1(DIN 2633)(3A0)

a1 125 125 - 125

h2 225 225 - 225

ConnectionsDIN 100/80 100/100 125/80 125/100 150/80 150/100OD 4 / 3 4 / 4 5 / 3 5 / 4 6 / 3 6 / 4

Kremo-flangeDIN EN 1092-1(DIN 2633)(3A0)

a1 125 125 - - - 125

h2 250 250 - - - 250

ConnectionsDIN 100/80 100/100 125/80 125/100 150/80 150/100OD 4 / 3 4 / 4 5 / 3 5 / 4 6 / 3 6 / 4

Kremo-flangeDIN EN 1092-1(DIN 2633)(3A0)

a1 125 - - 125 125 125

h2 280 - - 280 280 280

ConnectionsDIN 100/80 100/100 125/80 125/100 150/80 150/100OD 4 / 3 4 / 4 5 / 3 5 / 4 6 / 3 6 / 4

Kremo-flangeDIN EN 1092-1(DIN 2633)(3A0)

a1 125 125 125 125 125 125

h2 315 315 315 315 315 315

ConnectionsDIN 125/100 125/125 150/100 150/125OD 5 / 4 5 / 5 6 / 4 6 / 5

Kremo-flangeDIN EN 1092-1(DIN 2633)(3A0)

a1 125 125 125 125

h2 280 280 280 280

ConnectionsDIN 125/100 125/125 150/100 150/125OD 5 / 4 5 / 5 6 / 4 6 / 5

Kremo-flangeDIN EN 1092-1(DIN 2633)(3A0)

a1 140 140 - 140

h2 280 280 - 280

ConnectionsDIN 150/125 150/150 175/125 200/125 200/150OD 6 / 5 6 / 6 7 / 5 8 / 5 8 / 6

FlangeDIN EN 1092-1 3)

(DIN 2632)(3A0)

a1 - - - 140 -

h2 - - - 355 -

FlangeDIN EN 1092-1 3)

(DIN 2633)(3A0)

a1 140 140 140 - 140

h2 355 355 355 - 355

ConnectionsDIN 125/100 125/125 150/100 150/125OD 5 / 4 5 / 5 6 / 4 6 / 5

Kremo-flangeDIN EN 1092-1(DIN 2633)(3A0)

a1 140 140 140 140

h2 315 315 315 315

ConnectionsDIN 150/125 200/150OD 6 / 5 8 / 6

FlangeDIN EN 1092-1 3)

(DIN 2633)(3A0)

a1 140 140

h2 355 355

ConnectionsDIN 200/150 250/150 250/200OD 8 / 6 10 / 6 10 / 8

FlangeDIN EN 1092-1 3)

(DIN 2632)(3A0)

a1 160 160 160

h2 375 375 375

FlangeDIN EN 1092-1 3)

(DIN 2633)(3A0)

a1 160 160 -

h2 375 375 -

ConnectionsDIN 200/150 250/150 250/200OD 8 / 6 10 / 6 10 / 8

FlangeDIN EN 1092-1 3)

(DIN 2632)(3A0)

a1 160 160 160

h2 400 400 400

FlangeDIN EN 1092-1 3)

(DIN 2633)(3A0)

a1 - 160 -

h2 - 400 -

ConnectionsDIN 200/150 200/200OD 8 / 6 8 / 8

FlangeDIN EN 1092-1 3)

(DIN 2632)(3A0)

a1 160 160

h2 450 450

ConnectionsDIN 200/200 250/200OD 8 / 8 10 / 8

FlangeDIN EN 1092-1 3)

(DIN 2632)(3A0)

a1 175 175

h2 530 530

Tolerances to DIN EN 735 connection dimensions for centrifugal pumps.

3) DNs/DNd - fixed flange

43

Page 44: GRUNDFOS DATA BOOKLET - Unopomp7 Euro-HYGIA® Sanitary pumps Materials Design variations See page 27. Mechanical shaft seal Grundfos offers these seal arrangements: • single seal

44

Pipe connections Sanitary pumps

MAXANAMAXANA, frame size 32-160

MAXANA, frame size 32-200

MAXANA, frame size 40-160

MAXANA, frame size 40-200

MAXANA, frame size 50-125

MAXANA, frame size 50-160

MAXANA, frame size 50-200

MAXANA, frame size 65-125

MAXANA, frame size 65-160

MAXANA, frame size 65-200

MAXANA, frame size 65-250

ConnectionsDIN 50/32 50/40 65/32 65/40OD 2 / 1¼ 2 / 1½ 2½ / 1¼ 2½ / 1½

Kremo-flangeDIN EN 1092-1(DIN 2633)(3A0)

a1 80 80 80 80

h2 160 160 160 160

ConnectionsDIN 40/25 50/32 50/40 65/32 65/40 65/50OD 1½ / 1 2 / 1¼ 2 / 1½ 2½ / 1¼ 2½ / 1½ 2½ / 2

Kremo-flangeDIN EN 1092-1(DIN 2633)(3A0)

a1 - 80 80 80 80 80

h2 - 180 180 180 180 180

ConnectionsDIN 65/40 65/50 80/40 80/50OD 2½ / 1½ 2½ / 2 3 / 1½ 3 / 2

Kremo-flangeDIN EN 1092-1(DIN 2633)(3A0)

a1 80 80 80 80

h2 160 160 160 160

ConnectionsDIN 65/40 65/50 80/40 80/50OD 2½ / 1½ 2½ / 2 3 / 1½ 3 / 2

Kremo-flangeDIN EN 1092-1(DIN 2633)(3A0)

a1 100 100 100 100

h2 180 180 180 180

ConnectionsDIN 65/50 65/65 80/50 80/65OD 2½ / 2 2½ / 2½ 3 / 2 3 / 2½

Kremo-flangeDIN EN 1092-1(DIN 2633)(3A0)

a1 100 100 100 100

h2 160 160 160 160

ConnectionsDIN 65/50 65/65 80/50 80/65OD 2½ / 2 2½ / 2½ 3 / 2 3 / 2½

Kremo-flangeDIN EN 1092-1(DIN 2633)(3A0)

a1 100 100 100 100

h2 180 180 180 180

ConnectionsDIN 65/50 65/65 80/50 80/65OD 2½ / 2 2½ / 2½ 3 / 2 3 / 2½

Kremo-flangeDIN EN 1092-1(DIN 2633)(3A0)

a1 100 100 100 100

h2 200 200 200 200

ConnectionsDIN 80/65 100/65 80/80 100/80OD 3 / 2½ 3½ / 2½ 3 / 3 3½ / 3

Kremo-flangeDIN EN 1092-1(DIN 2633)(3A0)

a1 100 100 100 100

h2 180 180 180 180

ConnectionsDIN 80/65 80/80 100/65 100/80OD 3 / 2½ 3 / 3 3½ / 2½ 3½ / 3

Kremo-flangeDIN EN 1092-1(DIN 2633)(3A0)

a1 100 100 100 100

h2 200 200 200 200

ConnectionsDIN 80/65 80/80 100/65 100/80OD 3 / 2½ 3 / 3 3½ / 2½ 3½ / 3

Kremo-flangeDIN EN 1092-1(DIN 2633)(3A0)

a1 100 100 100 100

h2 225 225 225 225

ConnectionsDIN 80/65 80/80 100/65 100/80OD 3 / 2½ 3 / 3 3½ / 2½ 3½ / 3

Kremo-flangeDIN EN 1092-1(DIN 2633)(3A0)

a1 100 100 100 100

h2 250 250 250 250

Page 45: GRUNDFOS DATA BOOKLET - Unopomp7 Euro-HYGIA® Sanitary pumps Materials Design variations See page 27. Mechanical shaft seal Grundfos offers these seal arrangements: • single seal

Sanitary pumpsInstallation

Mechanical installationThe pump should never be installed with the motor pointing downwards.

Fig. 40 Installation

The pumps must be installed in such a way that strain from the pipework is not transferred to the pump housing.

When installed outdoors, the motor must be provided with a suitable cover to avoid condensation on the elec-tronic components and to protect pump and motor against the direct effects of the elements.

Space requirementsVertical installation• Pumps fitted with motors up to and including 4 kW

require a 300-mm clearance above the motor. See fig. 41.

• Pumps fitted with motors of 5.5 kW and up require at least a 1-metre clearance above the motor to al-low the use of lifting equipment. See fig. 41.

Fig. 41 Vertical installation

Horizontal installation• Pumps fitted with motors up to and including 4 kW

require a 300-mm clearance behind the motor. See fig. 42.

• Pumps fitted with motors of 5.5 kW and up require a 300-mm clearance behind and a 1-metre clearance above the motor to allow the use of lifting equip-ment. See fig. 42.

Fig. 42 Horizontal installation

TM03

011

3 40

04TM

03 0

114

4004

300 mm 1 m

0.55-4 kW 5.5-30 kW

TM03

011

5 40

04

0.55-4 kW

300 mm

5.5-30 kW

1 m

300 mm

45

Page 46: GRUNDFOS DATA BOOKLET - Unopomp7 Euro-HYGIA® Sanitary pumps Materials Design variations See page 27. Mechanical shaft seal Grundfos offers these seal arrangements: • single seal

46

Installation Sanitary pumps

Elimination of noise and vibrationIn order to achieve optimum operation and minimum noise and vibration, consider vibration dampening of the pump. Generally, always consider this for pumps with motors above 11 kW. Smaller motors, however, may also cause undesirable noise and vibration.

Noise and vibration are generated by the rotations in the motor and pump and by the flow in pipes and fit-tings. The effect on the environment is subjective and depends on correct installation and the state of the remaining system.

FoundationVibration dampening is best achieved by installing the pumps on a plane and rigid concrete foundation. See fig. 43.

Fig. 43 Example of foundation of a Contra II pump

As a rule of thumb, the weight of a concrete foundation should be 1.5 times the pump weight.

Vibration dampersTo prevent the transmission of vibrations to buildings, we recommend that you isolate the pump foundation from building parts by means of vibration dampers.

The selection of the right vibration damper requires these data:

• forces transmitted through the damper• motor speed considering speed control, if any• required dampening in % (suggested value is 70%).Which is the right damper varies from installation to installation, and a wrong damper may increase the vibration level. Vibration dampers should therefore be sized by the supplier.

Expansion jointsIf you install the pump on a foundation with vibration dampers, always fit expansion joints on the pump flanges. This is important to prevent the pump from "hanging" in the flanges.

Install expansion joints to

• absorb expansions/contractions in the pipework caused by changing liquid temperature

• reduce mechanical strains in connection with pres-sure surges in the pipework

• isolate mechanical structure-borne noise in the pipework (only rubber bellows expansion joints).

Note: Do not install expansion joints to compensate for inaccuracies in the pipework such as centre displace-ment of flanges.

Fit expansion joints at a distance of minimum 1 to 1½ times the nominal flange diameter away from the pump on the suction as well as on the discharge side. This will prevent the development of turbulence in the expansion joints, resulting in better suction conditions and a mini-mum pressure loss on the pressure side. At high water velocities (> 5 m/s), we recommend you to install larger expansion joints corresponding to the pipework.

Expansion joints with limiting rods can be used to mini-mise the forces caused by the expansion joints. We always recommend expansion joints with limiting rods for flanges larger than DN 100.

The pipes should be anchored so that they do not stress the expansion joints and the pump. Follow the supplier’s instructions and pass them on to advisers or pipe installers.

Terminal box positionsThe terminal box positions shown in fig. 44 are possible for all pump ranges.

Fig. 44 Possible terminal box positions

TM03

011

6 40

04

Expansion joint

Vibration damper

TM03

011

7 40

04

12 o’clock 3 o’clock 9 o’clock

Concrete foundation

Page 47: GRUNDFOS DATA BOOKLET - Unopomp7 Euro-HYGIA® Sanitary pumps Materials Design variations See page 27. Mechanical shaft seal Grundfos offers these seal arrangements: • single seal

47

Page 48: GRUNDFOS DATA BOOKLET - Unopomp7 Euro-HYGIA® Sanitary pumps Materials Design variations See page 27. Mechanical shaft seal Grundfos offers these seal arrangements: • single seal

48

Sanitary pumpsCurve charts

How to read the curve charts

TM02

972

2 37

04

0 20 40 60 80 100 120 140 160 180 Q [m³/h]

0

5

10

15

20

25

30

35

40

45

H[m]

MAXA 80-16050 Hz

/159/166

/173

/180

/187

0 20 40 60 80 100 120 140 160 180 Q [m³/h]

0

5

10

15

20

P2[kW]

/159/166

/173

/180

/187

0 20 40 60 80 100 120 140 160 180 Q [m³/h]

45

50

55

60

65

70

75

[%]Eta

/159/166

/173

/180

/187

0 20 40 60 80 100 120 140 160 180 Q [m³/h]

0

2

4

6

8

[m]NPSH

0 10 20 30 40 50 Q [l/s]

/159/166

/173

/180/187

Pump type and frequency

QH curve for the individual pump with a specific impeller diameter

The power curve indicates pump input power [P2] for the individual pump with a specific impeller diameter.

The eta curve indicates the pump efficiency for the individual pump with a specific impeller diameter.

The NPSH curve indicates the Net Positive Suction Head of the individual pump with a specific impeller diameter.

Page 49: GRUNDFOS DATA BOOKLET - Unopomp7 Euro-HYGIA® Sanitary pumps Materials Design variations See page 27. Mechanical shaft seal Grundfos offers these seal arrangements: • single seal

Curve charts Sanitary pumps

Curve conditionsThe guidelines below apply to the curves shown on the following pages:

1. Tolerances to ISO 9906, Annex A.

2. QH curves of the individual pumps are shown with expected speed of a three-phase standard motor.

3. Measurements have been made with airless water at a temperature of +20°C.

4. The curves apply to a kinematic viscosity of υ = 1 mm2/s (1 cSt).

5. If the pumped liquid density and/or viscosity is higher than that of water, it may be necessary to use a motor with a higher performance.

1 kW < P2 < 10 kWFlow rate: ±10%Total head: ±8%Efficiency: up to –16% *

* Efficiency of motor sizes below 10 kW are calculated on the basis of a formula stated in ISO 9906.

P2 > 10 kWFlow rate: ±9%Total head: ±7%Efficiency: –7%

49

Page 50: GRUNDFOS DATA BOOKLET - Unopomp7 Euro-HYGIA® Sanitary pumps Materials Design variations See page 27. Mechanical shaft seal Grundfos offers these seal arrangements: • single seal

50

Performance curves/Technical data

Euro-HYGIA® I2-pole

Euro-HYGIA® I4-pole

TM02

974

2 44

05

0 4 8 12 16 20 24 28 32 Q [m³/h]

0

5

10

15

20

25

30

35

40

45

50

55

H[m]

Euro-HYGIA I50 Hz

/185

/155

/120

0 4 8 12 16 20 24 28 32 Q [m³/h]

0

1

2

3

4

5

6

P2[kW]

/185

/155

/120

0 4 8 12 16 20 24 28 32 Q [m³/h]

25

30

35

40

45

50

55

60[%]Eta

/185/155

/120

0 4 8 12 16 20 24 28 32 Q [m³/h]

0.0

0.5

1.0

1.5

2.0

2.5

[m]NPSH

0 2 4 6 8 10 Q [l/s]

/185

/155

/120

TM02

974

1 44

05P

0 2 4 6 8 10 12 14 16 18 Q [m³/h]

0

1

2

3

4

5

6

7

8

9

10

11

12

H[m]

Euro-HYGIA I50 Hz

/130

/155

/185

0 2 4 6 8 10 12 14 16 18 Q [m³/h]

0.0

0.1

0.2

0.3

0.4

0.5

0.6

0.7

0.8

P2[kW]

/130

/155

/185

0 2 4 6 8 10 12 14 16 18 Q [m³/h]

25

30

35

40

45

50

55

60[%]Eta

/130

/155

/185

0 2 4 6 8 10 12 14 16 18 Q [m³/h]

0.0

0.5

1.0

1.5

2.0

2.5

[m]NPSH

0 1 2 3 4 5 Q [l/s]

/130

/155/185

Euro-HYGIA®I50 Hz

Page 51: GRUNDFOS DATA BOOKLET - Unopomp7 Euro-HYGIA® Sanitary pumps Materials Design variations See page 27. Mechanical shaft seal Grundfos offers these seal arrangements: • single seal

Technical data Euro-HYGIA®I50 Hz

Euro-HYGIA® I Adapta® on cast iron foot

Technical data

TM03

003

9 38

04

Annular housing with clamp ring (KLM)

Option

P2 [kW] n [min-1] IEC sizeOn cast iron foot

b k3(1) u(1)

0.55 1450 80 0 245 1450.75 1450 80 0 245 1451.1 2900 80 0 245 1451.1 1450 90S 10 285 1501.5 2900 90S 10 285 1501.5 1450 90L 10 285 1502.2 2900 90L 10 285 1502.2 1450 100L 20 320 1753.0 2900 100L 20 320 1754.0 2900 112M 20 340 1855.5 2900 132S 40 390 205

Dimensions depend on housing size (DNs, DNd, a1, h2, e1). See table of connections, page 31.

(1) Motor dimensions depend on make; motor dimensions show maximum size(2) Other sizes and special connections are available on request.(4) Largest diameter of pump without motor.(7) N-Eupex coupling.(8) Option: Drain-Gemü DN 15 diaphragm valve. Drain-clamp connection to DIN 32 676 DN 15 (45° angle).

51

Page 52: GRUNDFOS DATA BOOKLET - Unopomp7 Euro-HYGIA® Sanitary pumps Materials Design variations See page 27. Mechanical shaft seal Grundfos offers these seal arrangements: • single seal

52

Technical data Euro-HYGIA®I50 Hz

Euro-HYGIA® I Adapta® SUPER on stainless steel combi foot(frame size 80-90)

Technical data

TM03

004

0 38

04

Annular housing with clamp ring (KLM)

Option

P2 [kW] n [min-1] IEC sizeOn stainless steel combi foot

lH hH Ø dH

0.55 1450 80 370 180 3200.75 1450 80 370 180 3201.1 2900 80 370 180 3201.1 1450 90S 370 180 3201.5 2900 90S 370 180 3201.5 1450 90L 370 180 3202.2 2900 90L 370 180 320

Dimensions depend on housing size (DNs, DNd, a1, h2, e1). See table of connections, page 31.

(2) Other sizes and special connections are available on request.(4) Largest diameter of pump without motor.(7) N-Eupex coupling.(8) Option: Drain-Gemü DN 15 diaphragm valve. Drain-clamp connection to DIN 32 676 DN 15 (45° angle).

Page 53: GRUNDFOS DATA BOOKLET - Unopomp7 Euro-HYGIA® Sanitary pumps Materials Design variations See page 27. Mechanical shaft seal Grundfos offers these seal arrangements: • single seal

Technical data Euro-HYGIA®I50 Hz

Euro-HYGIA® I Adapta® SUPER on stainless steel combi foot (frame size 100-132)

Technical data

TM03

004

1 38

04

Annular housing with clamp ring (KLM)

Option

P2 [kW] n [min-1] IEC sizeOn stainless steel combi foot

lH hH Ø dH

2.2 1450 100L 460 210 3703.0 2900 100L 460 210 3704.0 2900 112M 460 210 3705.5 2900 132S 510 240 420

Dimensions depend on housing size (DNs, DNd, a1, h2, e1). See table of connections, page 31.

(2) Other sizes and special connections are available on request.(4) Largest diameter of pump without motor.(7) N-Eupex coupling.(8) Option: Drain-Gemü DN 15 diaphragm valve. Drain-clamp connection to DIN 32 676 DN 15 (45° angle).

53

Page 54: GRUNDFOS DATA BOOKLET - Unopomp7 Euro-HYGIA® Sanitary pumps Materials Design variations See page 27. Mechanical shaft seal Grundfos offers these seal arrangements: • single seal

54

Technical data Euro-HYGIA®I50 Hz

Euro-HYGIA® I Bloc on cast iron foot

Technical data

TM03

004

2 38

04Option

Annular housing with clamp ring (KLM)

P2 [kW] n [min-1] IEC sizeOn cast iron foot

k3(1) u(1)

0.55 1450 80 258 1240.75 1450 80 258 1241.1 2900 80 258 1241.1 1450 90S 282 1301.5 2900 90S 282 1301.5 1450 90L 282 1302.2 2900 90L 282 1302.2 1450 100L 327 1583.0 2900 100L 327 1584.0 2900 112M 355 1715.5 2900 112M 391 171

Dimensions depend on housing size (DNs, DNd, a1, h2, e1). See table of connections, page 31.

(1) Motor dimensions depend on make; motor dimensions show maximum size.(2) Other sizes and special connections are available on request.(4) Largest diameter of pump without motor.(8) Option: Drain-Gemü DN 15 diaphragm valve. Drain-clamp connection to DIN 32 676 DN 15 (45° angle).

Page 55: GRUNDFOS DATA BOOKLET - Unopomp7 Euro-HYGIA® Sanitary pumps Materials Design variations See page 27. Mechanical shaft seal Grundfos offers these seal arrangements: • single seal

Technical data Euro-HYGIA®I50 Hz

Euro-HYGIA® I Bloc-SUPER on stainless steel combi foot

Technical data

TM03

004

3 38

04Option

Annular housing with clamp ring (KLM)

P2 [kW] n [min-1] IEC sizeOn stainless steel combi foot

l lH Ø dH

0.55 1450 80 470 410 2200.75 1450 80 470 410 2201.1 2900 80 470 410 2201.1 1450 90S 470 410 2201.5 2900 90S 470 410 2201.5 1450 90L 470 410 2202.2 2900 90L 470 410 2202.2 1450 100L 540 480 2703.0 2900 100L 540 480 2704.0 2900 112M 540 480 2705.5 2900 112M 580 520 270

Dimensions depend on housing size (DNs, DNd, a1, h2, e1). See table of connections, page 31.

(2) Other sizes and special connections are available on request.(4) Largest diameter of pump without motor.(8) Option: Drain-Gemü DN 15 diaphragm valve. Drain-clamp connection to DIN 32 676 DN 15 (45° angle).

55

Page 56: GRUNDFOS DATA BOOKLET - Unopomp7 Euro-HYGIA® Sanitary pumps Materials Design variations See page 27. Mechanical shaft seal Grundfos offers these seal arrangements: • single seal

56

Euro-HYGIA®II50 HzPerformance curves

Euro-HYGIA® II2-pole

Euro-HYGIA® II4-pole

TM02

974

6 44

05

0 10 20 30 40 50 60 70 80 90 Q [m³/h]

0

10

20

30

40

50

60

70

80

90

H[m]

Euro-HYGIA II50 Hz

/190

/210

/230

0 10 20 30 40 50 60 70 80 90 Q [m³/h]

0

5

10

15

20

25

P2[kW]

/190

/210/230

0 10 20 30 40 50 60 70 80 90 Q [m³/h]

35

40

45

50

55

60

65

70[%]Eta

/190/210

/230

0 10 20 30 40 50 60 70 80 90 Q [m³/h]

0

1

2

3

4

5

[m]NPSH

0 5 10 15 20 25 Q [l/s]

/190/210

/230

TM02

974

5 44

05

0 5 10 15 20 25 30 35 40 45 Q [m³/h]

0

2

4

6

8

10

12

14

16

18

20

H[m]

Euro-HYGIA II50 Hz

/190

/210

/230

0 5 10 15 20 25 30 35 40 45 Q [m³/h]

0.0

0.5

1.0

1.5

2.0

2.5

3.0

3.5

P2[kW]

/190

/210

/230

0 5 10 15 20 25 30 35 40 45 Q [m³/h]

35

40

45

50

55

60

65

70[%]Eta

/190

/210

/230

0 5 10 15 20 25 30 35 40 45 Q [m³/h]

0.0

0.5

1.0

1.5

2.0

2.5

3.0

[m]NPSH

0 2 4 6 8 10 12 14 Q [l/s]

/190

/210

/230

Page 57: GRUNDFOS DATA BOOKLET - Unopomp7 Euro-HYGIA® Sanitary pumps Materials Design variations See page 27. Mechanical shaft seal Grundfos offers these seal arrangements: • single seal

Euro-HYGIA®II50 HzTechnical data

Euro-HYGIA® II Adapta® on Adapta® foot(frame size 180M)

Technical data

TM03

005

6 38

04Option

P2 [kW] n [min-1] IEC sizeOn cast iron foot

k3(1) u(1)

22.0 2900 180M 605 265

Dimensions depend on housing size (DNs, DNd, a1, h2, e1). See table of connections, page 32.

(1) Motor dimensions depend on make; motor dimensions show maximum size.(2) Other sizes and special connections are available on request.(4) Largest diameter of pump without motor.(7) N-Eupex coupling.(8) Option: Drain-Gemü DN 15 diaphragm valve. Drain-clamp connection to DIN 32 676 DN 15 (45° angle).

Annular housing with clamp ring (KLM)

57

Page 58: GRUNDFOS DATA BOOKLET - Unopomp7 Euro-HYGIA® Sanitary pumps Materials Design variations See page 27. Mechanical shaft seal Grundfos offers these seal arrangements: • single seal

58

Euro-HYGIA®II50 HzTechnical data

Euro-HYGIA® II Adapta® on cast iron foot(frame size 100-160)

Technical data

TM03

005

7 38

04

Annular housing with clamp ring (KLM)

Option

P2 [kW] n [min-1] IEC sizeOn cast iron foot

b k3(1) u(1)

2.2 1450 100L 0 320 1753.0 1450 100L 0 320 1753.0 2900 100L 0 320 1754.0 1450 112M 0 340 1854.0 2900 112M 0 340 1855.5 1450 132S 20 390 2055.5 2900 132S 20 390 2057.5 2900 132S 20 390 2057.5 1450 132M 20 420 20511.0 2900 160M 51 490 24015.0 2900 160M 51 490 24018.5 2900 160L 51 530 240

Dimensions depend on housing size (DNs, DNd, a1, h2, e1). See table of connections, page 32.

(1) Motor dimensions depend on make; motor dimensions show maximum size.(2) Other sizes and special connections are available on request.(4) Largest diameter of pump without motor.(7) N-Eupex coupling.(8) Option: Drain-Gemü DN 15 diaphragm valve. Drain-clamp connection to DIN 32 676 DN 15 (45° angle).

Page 59: GRUNDFOS DATA BOOKLET - Unopomp7 Euro-HYGIA® Sanitary pumps Materials Design variations See page 27. Mechanical shaft seal Grundfos offers these seal arrangements: • single seal

Euro-HYGIA®II50 HzTechnical data

Euro-HYGIA® II Adapta® SUPER on stainless steel combi foot (frame size 100-160)

Technical data

TM03

005

9 38

04

Annular housing with clamp ring (KLM)

P2 [kW] n [min-1] IEC sizeOn stainless steel combi foot

lH hH Ø dH

2.2 1450 100L 510 240 4203.0 1450 100L 510 240 4203.0 2900 100L 510 240 4204.0 1450 112M 510 240 4204.0 2900 112M 510 240 4205.5 1450 132S 510 240 4205.5 2900 132S 510 240 4207.5 2900 132S 510 240 4207.5 1450 132M 510 240 42011.0 2900 160M 650 285 48515.0 2900 160M 650 285 48518.5 2900 160L 650 285 485

Dimensions depend on housing size (DNs, DNd, a1, h2, e1). See table of connections, page 32.

(2) Other sizes and special connections are available on request.(4) Largest diameter of pump without motor.(7) N-Eupex coupling.(8) Option: Drain-Gemü DN 15 diaphragm valve. Drain-clamp connection to DIN 32 676 DN 15 (45° angle).

Option

59

Page 60: GRUNDFOS DATA BOOKLET - Unopomp7 Euro-HYGIA® Sanitary pumps Materials Design variations See page 27. Mechanical shaft seal Grundfos offers these seal arrangements: • single seal

60

Euro-HYGIA®II50 HzTechnical data

Euro-HYGIA® II Adapta® SUPER on machine pads(frame size 180)

Technical data

TM03

005

8 38

04Option

P2 [kW] n [min-1] IEC size22.0 2900 180M

Dimensions depend on housing size (DNs, DNd, a1, h2, e1). See table of connections, page 32.

(2) Other sizes and special connections are available on request.(4) Largest diameter of pump without motor.(7) N-Eupex coupling.(8) Option: Drain-Gemü DN 15 diaphragm valve. Drain-clamp connection to DIN 32 676 DN 15 (45° angle).

Annular housing with clamp ring (KLM)

Page 61: GRUNDFOS DATA BOOKLET - Unopomp7 Euro-HYGIA® Sanitary pumps Materials Design variations See page 27. Mechanical shaft seal Grundfos offers these seal arrangements: • single seal

Euro-HYGIA®II50 HzTechnical data

Euro-HYGIA® II Bloc on cast iron foot(frame size 90-132)

Technical data

TM03

006

0 38

04215

250225

85

27.5

220

275

22

ø14

Annular housing with clamp ring (KLM)

Option

P2 [kW] n [min-1] IEC sizeOn cast iron foot

k3(1) u(1)

0.75 1450 90S 282 1301.5 1450 90L 282 1301.5 2900 90S 282 1302.2 2900 90L 282 1302.2 1450 100L 312 1633.0 1450 100L 312 1633.0 2900 100L 312 1634.0 1450 112M 335 1764.0 2900 112M 335 1765.5 1450 112M 371 1765.5 2900 112M 371 1767.5 1450 132M 433 1967.5 2900 132S 433 19611.0 2900 132M 433 196

Dimensions depend on housing size (DNs, DNd, a1, h2, e1). See table of connections, page 32.

(1) Motor dimensions depend on make; motor dimensions show maximum size.(2) Other sizes and special connections are available on request.(4) Largest diameter of pump without motor.(8) Option: Drain-Gemü DN 15 diaphragm valve. Drain-clamp connection to DIN 32 676 DN 15 (45° angle).

61

Page 62: GRUNDFOS DATA BOOKLET - Unopomp7 Euro-HYGIA® Sanitary pumps Materials Design variations See page 27. Mechanical shaft seal Grundfos offers these seal arrangements: • single seal

62

Euro-HYGIA®II50 HzTechnical data

Euro-HYGIA® II Bloc on motor foot with stainless steel plinth(frame size 160)

Technical data

TM03

006

1 38

04

Annular housing with clamp ring (KLM)

Option

P2 [kW] n [min-1] IEC sizeOn motor foot with stainless steel plinth

k3(1) u(1) m1 m2 ø s n1 n2

15.0 2900 160M 522 226 310 250 13 410 38018.5 2900 160L 562 226 310 250 13 410 38022.0 2900 160L 562 226 310 250 13 410 380

Dimensions depend on housing size (DNs, DNd, a1, h2, e1). See table of connections, page 32.

(1) Motor dimensions depend on make; motor dimensions show maximum size.(2) Other sizes and special connections are available on request.(4) Largest diameter of pump without motor.(8) Option: Drain-Gemü DN 15 diaphragm valve. Drain-clamp connection to DIN 32 676 DN 15 (45° angle).

Page 63: GRUNDFOS DATA BOOKLET - Unopomp7 Euro-HYGIA® Sanitary pumps Materials Design variations See page 27. Mechanical shaft seal Grundfos offers these seal arrangements: • single seal

Euro-HYGIA®II50 HzTechnical data

Euro-HYGIA® II Bloc-SUPER on stainless steel combi foot(frame size 90 - 132)

Technical data

TM03

006

2 38

04

Annular housing with clamp ring (KLM)

Option

P2 [kW] n [min-1] IEC sizeOn stainless steel combi foot

l lH Ø dH

0.75 1450 90S 540 480 2701.5 1450 90L 540 480 2701.5 2900 90S 540 480 2702.2 2900 90L 540 480 2702.2 1450 100L 540 480 2703.0 1450 100L 540 480 2703.0 2900 100L 540 480 2704.0 1450 112M 540 480 2704.0 2900 112M 540 480 2705.5 1450 112M 580 520 2705.5 2900 112M 580 520 2707.5 1450 132M 660 600 3207.5 2900 132S 660 600 32011.0 2900 132M 660 600 320

Dimensions depend on housing size (DNs, DNd, a1, h2, e1). See table of connections, page 32.

(2) Other sizes and special connections are available on request.(4) Largest diameter of pump without motor.(8) Option: Drain-Gemü DN 15 diaphragm valve. Drain-clamp connection to DIN 32 676 DN 15 (45° angle).

63

Page 64: GRUNDFOS DATA BOOKLET - Unopomp7 Euro-HYGIA® Sanitary pumps Materials Design variations See page 27. Mechanical shaft seal Grundfos offers these seal arrangements: • single seal

64

Euro-HYGIA®II50 HzTechnical data

Euro-HYGIA® II Bloc-SUPER on stainless steel combi foot(frame size 160)

Technical data

TM03

006

3 38

04

Annular housing with clamp ring (KLM)

Option

P2 [kW] n [min-1] IEC sizeOn stainless steel combi foot

l lH Ø dH

15.0 2900 160M 810 750 35018.5 2900 160L 810 750 35022.0 2900 160L 810 750 350

Dimensions depend on housing size (DNs, DNd, a1, h2, e1). See table of connections, page 32.

(2) Other sizes and special connections are available on request.(4) Largest diameter of pump without motor.(8) Option: Drain-Gemü DN 15 diaphragm valve. Drain-clamp connection to DIN 32 676 DN 15 (45° angle).

Page 65: GRUNDFOS DATA BOOKLET - Unopomp7 Euro-HYGIA® Sanitary pumps Materials Design variations See page 27. Mechanical shaft seal Grundfos offers these seal arrangements: • single seal

65

Page 66: GRUNDFOS DATA BOOKLET - Unopomp7 Euro-HYGIA® Sanitary pumps Materials Design variations See page 27. Mechanical shaft seal Grundfos offers these seal arrangements: • single seal

66

F&B-HYGIA® I50 HzPerformance curves

F&B-HYGIA® I2-pole

F&B-HYGIA® I4-pole

TM03

359

3 04

06

0 4 8 12 16 20 24 28 32 Q [m³/h]

0

5

10

15

20

25

30

35

40

45

50

55

H[m]

F&B-HYGIA I50 Hz

/120

/155

/185

0 4 8 12 16 20 24 28 32 Q [m³/h]

0

1

2

3

4

5

6

P2[kW]

/120

/155

/185

0 4 8 12 16 20 24 28 32 Q [m³/h]

25

30

35

40

45

50

55

60[%]Eta

/120

/155/185

0 4 8 12 16 20 24 28 32 Q [m³/h]

0.0

0.5

1.0

1.5

2.0

2.5

[m]NPSH

0 2 4 6 8 10 Q [l/s]

/120/155

/185

TM03

359

2 04

06

0 2 4 6 8 10 12 14 16 18 Q [m³/h]

0

1

2

3

4

5

6

7

8

9

10

11

12

H[m]

F&B-HYGIA I50 Hz

/130

/155

/185

0 2 4 6 8 10 12 14 16 18 Q [m³/h]

0.0

0.1

0.2

0.3

0.4

0.5

0.6

0.7

0.8

P2[kW]

/130

/155

/185

0 2 4 6 8 10 12 14 16 18 Q [m³/h]

25

30

35

40

45

50

55

60[%]Eta

/130

/155

/185

0 2 4 6 8 10 12 14 16 18 Q [m³/h]

0.0

0.5

1.0

1.5

2.0

2.5

[m]NPSH

0 1 2 3 4 5 Q [l/s]

/130

/155/185

Page 67: GRUNDFOS DATA BOOKLET - Unopomp7 Euro-HYGIA® Sanitary pumps Materials Design variations See page 27. Mechanical shaft seal Grundfos offers these seal arrangements: • single seal

F&B-HYGIA® I50 HzTechnical data

F&B-HYGIA® I K on motor foot

Technical data

TM03

379

1 10

06

P2 [kW] n [min-1] IEC sizeOn motor foot

k3 u a m2 n2 n1 s1 h1 o1,1 1450 90S 281 110 227,5 100 140 178 10 90 601,5 2900 90S 281 110 227,5 100 140 178 10 90 601,5 1450 90L 281 110 227,5 100 140 178 10 90 602,2 2900 90L 281 110 227,5 100 140 178 10 90 602,2 1450 100L 335 110 234 140 160 178 12 100 503 2900 100L 335 110 234 140 160 178 12 100 504 2900 112M 372 134 241 140 190 228 12 112 38

5,5 2900 132S 391 134 260 140 216 255 12 132 18

Dimensions depend on housing size (DNs, DNd, a1, h2, e1). See table of connections, page 33.

Grundfos MG motors, model C, are fitted up to 11 kW, 2-pole, and 5.5 kW, 4-pole

67

Page 68: GRUNDFOS DATA BOOKLET - Unopomp7 Euro-HYGIA® Sanitary pumps Materials Design variations See page 27. Mechanical shaft seal Grundfos offers these seal arrangements: • single seal

68

F&B-HYGIA® I50 HzTechnical data

F&B-HYGIA® I K on cast iron foot

Technical data

TM03

379

2 10

06

P2 [kW] n [min-1] IEC sizeOn cast iron foot

k3 u1,1 1450 90S 281 1101,5 2900 90S 281 1101,5 1450 90L 281 1102,2 2900 90L 281 1102,2 1450 100L 335 1103 2900 100L 335 1104 2900 112M 372 134

5,5 2900 132S 391 134

Dimensions depend on housing size (DNs, DNd, a1, h2, e1). See table of connections, page 33.

Grundfos MG motors, model C, are fitted up to 11 kW, 2-pole, and 5.5 kW, 4-pole

Page 69: GRUNDFOS DATA BOOKLET - Unopomp7 Euro-HYGIA® Sanitary pumps Materials Design variations See page 27. Mechanical shaft seal Grundfos offers these seal arrangements: • single seal

F&B-HYGIA® I50 HzTechnical data

F&B-HYGIA® I K on combi foot

Technical data

TM03

378

9 10

06

P2 [kW] n [min-1] IEC sizeOn combi foot

k3 u1,1 1450 90S 281 1101,5 2900 90S 281 1101,5 1450 90L 281 1102,2 2900 90L 281 1102,2 1450 100L 335 1103 2900 100L 335 1104 2900 112M 372 134

5,5 2900 132S 391 134

Dimensions depend on housing size (DNs, DNd, a1, h2, e1). See table of connections, page 33.

Grundfos MG motors, model C, are fitted up to 11 kW, 2-pole, and 5.5 kW, 4-pole

69

Page 70: GRUNDFOS DATA BOOKLET - Unopomp7 Euro-HYGIA® Sanitary pumps Materials Design variations See page 27. Mechanical shaft seal Grundfos offers these seal arrangements: • single seal

70

F&B-HYGIA® I50 HzTechnical data

F&B-HYGIA® I K SUPER on combi foot

Technical data

TM03

379

0 10

06

P2 [kW] n [min-1] IEC sizeOn combi foot

I lH hH Ø dH

1,1 1450 90S 481 316 160 3201,5 2900 90S 481 316 160 3201,5 1450 90L 481 316 160 3202,2 2900 90L 481 316 160 3202,2 1450 100L 591 426 160 3203 2900 100L 591 426 160 3204 2900 112M 591 426 160 320

5,5 2900 132S 591 426 160 320

Dimensions depend on housing size (DNs, DNd, a1, h2, e1). See table of connections, page 33.

Grundfos MG motors, model C, are fitted up to 11 kW, 2-pole, and 5.5 kW, 4-pole

Page 71: GRUNDFOS DATA BOOKLET - Unopomp7 Euro-HYGIA® Sanitary pumps Materials Design variations See page 27. Mechanical shaft seal Grundfos offers these seal arrangements: • single seal

71

Page 72: GRUNDFOS DATA BOOKLET - Unopomp7 Euro-HYGIA® Sanitary pumps Materials Design variations See page 27. Mechanical shaft seal Grundfos offers these seal arrangements: • single seal

72

F&B-HYGIA® II50 HzPerformance curves

F&B-HYGIA® II2-pole

F&B-HYGIA® II4-pole

TM03

359

5 04

06

0 10 20 30 40 50 60 70 80 90 Q [m³/h]

0

10

20

30

40

50

60

70

80

90

H[m]

F&B-HYGIA II50 Hz

/190

/210

/230

0 10 20 30 40 50 60 70 80 90 Q [m³/h]

0

5

10

15

20

P2[kW]

/190/210/230

0 10 20 30 40 50 60 70 80 90 Q [m³/h]

35

40

45

50

55

60

65

70[%]Eta

/190

/210

/230

0 10 20 30 40 50 60 70 80 90 Q [m³/h]

0

1

2

3

4

5

[m]NPSH

0 5 10 15 20 25 Q [l/s]

/190

/210/230

TM03

359

4 04

06

0 5 10 15 20 25 30 35 40 45 Q [m³/h]

0

2

4

6

8

10

12

14

16

18

20

H[m]

F&B-HYGIA II50 Hz

/190

/210

/230

0 5 10 15 20 25 30 35 40 45 Q [m³/h]

0.0

0.5

1.0

1.5

2.0

2.5

3.0

3.5

P2[kW]

/190

/210

/230

0 5 10 15 20 25 30 35 40 45 Q [m³/h]

35

40

45

50

55

60

65

70[%]Eta

/190/210

/230

0 5 10 15 20 25 30 35 40 45 Q [m³/h]

0.0

0.5

1.0

1.5

2.0

2.5

3.0

[m]NPSH

0 2 4 6 8 10 12 14 Q [l/s]

/190

/210

/230

Page 73: GRUNDFOS DATA BOOKLET - Unopomp7 Euro-HYGIA® Sanitary pumps Materials Design variations See page 27. Mechanical shaft seal Grundfos offers these seal arrangements: • single seal

F&B-HYGIA® II50 HzTechnical data

F&B-HYGIA® II K on motor foot

Technical data

TM03

379

4 10

06

P2 [kW] n [min-1] IEC sizeOn motor foot

k3 u a m2 n2 n1 s1 h1 o2,2 1450 100L 335 110 265 140 160 178 12 100 753 1450 100L 335 110 265 140 160 178 12 100 753 2900 100L 372 134 265 140 160 178 12 100 754 1450 112M 372 134 272 140 190 228 12 112 634 2900 112M 372 134 272 140 190 228 12 112 63

5,5 1450 132S 391 134 291 140 216 255 12 132 435,5 2900 132S 391 134 291 140 216 255 12 132 437,5 2900 132S 391 134 291 140 216 255 12 132 4311 2900 160M 464 172 309 210 254 302 15 160 1515 2900 160M 500 255 309 210 254 - 15 160 15

18,5 2900 160L 555 255 309 254 254 - 15 160 15

Dimensions depend on housing size (DNs, DNd, a1, h2, e1). See table of connections, page 33.

Grundfos MG motors, model C, with mounting designation B5 are fitted up to 11 kW, 2-pole, and 5.5 kW, 4-pole15 kW and 18.5 kW are Siemens motors

73

Page 74: GRUNDFOS DATA BOOKLET - Unopomp7 Euro-HYGIA® Sanitary pumps Materials Design variations See page 27. Mechanical shaft seal Grundfos offers these seal arrangements: • single seal

74

F&B-HYGIA® II50 HzTechnical data

F&B-HYGIA® II K on cast iron foot

Technical data

TM03

379

8 10

06

P2 [kW] n [min-1] IEC sizeOn cast iron foot

k3 u2,2 1450 100L 335 1103 1450 100L 335 1103 2900 100L 372 1344 1450 112M 372 1344 2900 112M 372 134

5,5 1450 132S 391 1345,5 2900 132S 391 1347,5 2900 132S 391 134

Dimensions depend on housing size (DNs, DNd, a1, h2, e1). See table of connections, page 33.

Grundfos MG motors, model C, with mounting designation B5 are fitted up to 11 kW, 2-pole, and 5.5 kW, 4-pole

Page 75: GRUNDFOS DATA BOOKLET - Unopomp7 Euro-HYGIA® Sanitary pumps Materials Design variations See page 27. Mechanical shaft seal Grundfos offers these seal arrangements: • single seal

F&B-HYGIA® II50 HzTechnical data

F&B-HYGIA® II K on combi foot(frame size 100-132)

Technical data

TM03

379

7 10

06

P2 [kW] n [min-1] IEC sizeOn combi foot

k3 u2.2 1450 100L 335 1103 2900 100L 335 1103 1450 112M 372 1344 1450 112M 372 1344 2900 112M 372 134

5.5 1450 132S 391 1345.5 2900 132S 391 1347.5 2900 132S 391 134

Dimensions depend on housing size (DNs, DNd, a1, h2, e1). See table of connections, page 33.

Grundfos MG motors, model C, with mounting designation B5 are fitted up to 11 kW, 2-pole, and 5.5 kW, 4-pole

75

Page 76: GRUNDFOS DATA BOOKLET - Unopomp7 Euro-HYGIA® Sanitary pumps Materials Design variations See page 27. Mechanical shaft seal Grundfos offers these seal arrangements: • single seal

76

F&B-HYGIA® II50 HzTechnical data

F&B-HYGIA® II K on combi foot(frame size 160)

Technical data

TM03

389

6 11

06

P2 [kW] n [min-1] IEC sizeOn combi foot

k3 u11 2900 160M 464 17215 2900 160M 500 255

18.5 2900 160L 555 255

Dimensions depend on housing size (DNs, DNd, a1, h2, e1). See table of connections, page 33.

Grundfos MG motors, model C, with mounting designation B5 are fitted up to 11 kW, 2-pole, and 5.5 kW, 4-pole15 kW and 18.5 kW are Siemens motors

Page 77: GRUNDFOS DATA BOOKLET - Unopomp7 Euro-HYGIA® Sanitary pumps Materials Design variations See page 27. Mechanical shaft seal Grundfos offers these seal arrangements: • single seal

F&B-HYGIA® II50 HzTechnical data

F&B-HYGIA® II K SUPER on combi foot(frame size 100-132)

Technical data

TM03

379

6 10

06

P2 [kW] n [min-1] IEC sizeOn combi foot

I lH hH Ø dH

2.2 1450 100L 702 506 185 3703 1450 100L 702 506 185 3703 2900 100L 702 506 185 3704 1450 112M 702 506 185 3704 2900 112M 702 506 185 370

5.5 1450 132S 702 506 185 3705.5 2900 132S 702 506 185 3707.5 2900 132S 702 506 185 370

Dimensions depend on housing size (DNs, DNd, a1, h2, e1). See table of connections, page 33.

Grundfos MG motors, model C, with mounting designation B5 are fitted up to 11 kW, 2-pole, and 5.5 kW, 4-pole

77

Page 78: GRUNDFOS DATA BOOKLET - Unopomp7 Euro-HYGIA® Sanitary pumps Materials Design variations See page 27. Mechanical shaft seal Grundfos offers these seal arrangements: • single seal

78

F&B-HYGIA® II50 HzTechnical data

F&B-HYGIA® II K SUPER on combi foot(frame size 160)

Technical data

TM03

378

8 10

06

P2 [kW] n [min-1] IEC sizeOn combi foot

I lH hH Ø dH

11 2900 160M 702 506 185 37015 2900 160M 778 583 282.5 485

18.5 2900 160L 778 583 282.5 485

Dimensions depend on housing size (DNs, DNd, a1, h2, e1). See table of connections, page 33.

Grundfos MG motors, model C, with mounting designation B5 are fitted up to 11 kW, 2-pole, and 5.5 kW, 4-pole15 kW and 18.5 kW are Siemens motors

Page 79: GRUNDFOS DATA BOOKLET - Unopomp7 Euro-HYGIA® Sanitary pumps Materials Design variations See page 27. Mechanical shaft seal Grundfos offers these seal arrangements: • single seal

79

Page 80: GRUNDFOS DATA BOOKLET - Unopomp7 Euro-HYGIA® Sanitary pumps Materials Design variations See page 27. Mechanical shaft seal Grundfos offers these seal arrangements: • single seal

80

Contra I50 HzPerformance curves

Contra I2-pole

TM02

974

9 44

05

0 2 4 6 8 10 12 14 16 18 20 Q [m³/h]

0

10

20

30

40

50

60

70

80

90

100

110

H[m]

Contra I50 Hz

-1

-2

-3

-4

-5

-6

0 2 4 6 8 10 12 14 16 18 20 Q [m³/h]

0

1

2

3

4

5

6

P2[kW]

-1

-2

-3

-4

-5

-6

0 2 4 6 8 10 12 14 16 18 20 Q [m³/h]

20

25

30

35

40

45

50

55[%]Eta

-1

-2

-3

-4-5

-6

0 2 4 6 8 10 12 14 16 18 20 Q [m³/h]

0

1

2

3

4

5

[m]NPSH

0 1 2 3 4 5 6 Q [l/s]

-1

-2

-3

-4-5

-6

Page 81: GRUNDFOS DATA BOOKLET - Unopomp7 Euro-HYGIA® Sanitary pumps Materials Design variations See page 27. Mechanical shaft seal Grundfos offers these seal arrangements: • single seal

Contra I50 HzTechnical data

Contra I Adapta® on cast iron foot

Technical data

TM03

006

4 38

04

P2 [kW] n [min-1] IEC sizeOn cast iron foot

b k3(1) u(1)

0.55 1450 80 0 245 1450.75 1450 80 0 245 1450.75 2900 80 0 245 1451.1 2900 80 0 245 1451.1 1450 90S 10 285 1501.5 2900 90S 10 285 1501.5 1450 90L 10 285 1502.2 2900 90L 10 285 1502.2 1450 100L 20 320 1753.0 2900 100L 20 320 1754.0 2900 112M 20 340 1855.5 2900 132S 40 390 205

Dimensions depend on housing size (DNs, DNd, a1, f2, h2). See table of connections, page 34.

(1) Motor dimensions depend on make; motor dimensions show maximum size.(2) Other sizes and special connections are available on request.(4) Largest diameter of pump without motor.(7) Coupling of our choice.

81

Page 82: GRUNDFOS DATA BOOKLET - Unopomp7 Euro-HYGIA® Sanitary pumps Materials Design variations See page 27. Mechanical shaft seal Grundfos offers these seal arrangements: • single seal

82

Contra I50 HzTechnical data

Contra I Adapta® SUPER on stainless steel combi foot(frame size 80-90)

Technical data

TM03

006

5 38

04

P2 [kW] n [min-1] IEC sizeOn stainless steel combi foot

lH hH Ø dH

0.55 1450 80 370 180 3200.75 1450 80 370 180 3200.75 2900 80 370 180 3201.1 2900 80 370 180 3201.1 1450 90S 370 180 3201.5 2900 90S 370 180 3201.5 1450 90L 370 180 3202.2 2900 90L 370 180 320

Dimensions depend on housing size (DNs, DNd, a1, f2, h2). See table of connections, page 34.

(2) Other sizes and special connections are available on request.(4) Largest diameter of pump without motor.(7) Coupling of our choice.

Page 83: GRUNDFOS DATA BOOKLET - Unopomp7 Euro-HYGIA® Sanitary pumps Materials Design variations See page 27. Mechanical shaft seal Grundfos offers these seal arrangements: • single seal

Contra I50 HzTechnical data

Contra I Adapta® SUPER on stainless steel combi foot(frame size 100-132)

Technical data

TM03

006

6 38

04

404 300

320

P2 [kW] n [min-1] IEC sizeOn stainless steel combi foot

lH hH Ø dH

2.2 1450 100L 460 210 3703.0 2900 100L 460 210 3704.0 2900 112M 460 210 3705.5 2900 132S 510 240 420

Dimensions depend on housing size (DNs, DNd, a1, f2, h2). See table of connections, page 34.

(2) Other sizes and special connections are available on request.(4) Largest diameter of pump without motor.(7) Coupling of our choice.

83

Page 84: GRUNDFOS DATA BOOKLET - Unopomp7 Euro-HYGIA® Sanitary pumps Materials Design variations See page 27. Mechanical shaft seal Grundfos offers these seal arrangements: • single seal

84

Contra I50 HzTechnical data

Contra I Adapta®-V on stainless steel pedestal with/without suction elbow

Technical data

TM03

006

7 38

04

For installing, removing and servicing the pump, lifting points should be arranged directly above the pump and removable lengths incorporated into the suction line.

P2 [kW] n [min-1] IEC sizeOn stainless steel pedestal with/without suction elbow

b k3(1) u(1)

0.55 1450 80 0 245 1450.75 1450 80 0 245 1450.75 2900 80 0 245 1451.1 2900 80 0 245 1451.1 1450 90S 10 285 1501.5 2900 90S 10 285 1501.5 1450 90L 10 285 1502.2 2900 90L 10 285 1502.2 1450 100L 20 320 1753.0 2900 100L 20 320 1754.0 2900 112M 20 340 1855.5 2900 132S 40 390 205

Dimensions depend on housing size (DNs, DNd, a1, e5, f2, h2, h3). See table of connections, page 34.

(1) Motor dimensions depend on make; motor dimensions show maximum size.(2) Other sizes and special connections are available on request.(4) Largest diameter of pump without motor.(7) Coupling of our choice.

Page 85: GRUNDFOS DATA BOOKLET - Unopomp7 Euro-HYGIA® Sanitary pumps Materials Design variations See page 27. Mechanical shaft seal Grundfos offers these seal arrangements: • single seal

Contra I50 HzTechnical data

Contra I Bloc on cast iron foot

Technical data

TM03

006

8 38

04

P2 [kW] n [min-1] IEC sizeOn cast iron foot

k3(1) u(1)

0.55 1450 80 258 1240.75 1450 80 258 1240.75 2900 80 258 1241.1 2900 80 258 1241.1 1450 90S 282 1301.5 2900 90S 282 1301.5 1450 90L 282 1302.2 2900 90L 282 1302.2 1450 100L 332 1583.0 2900 100L 332 1584.0 2900 112M 391 1715.5 2900 112M 391 171

Dimensions depend on housing size (DNs, DNd, a1, f2, h2). See table of connections, page 34.

(1) Motor dimensions depend on make; motor dimensions show maximum size.(2) Other sizes and special connections are available on request.(4) Largest diameter of pump without motor.

85

Page 86: GRUNDFOS DATA BOOKLET - Unopomp7 Euro-HYGIA® Sanitary pumps Materials Design variations See page 27. Mechanical shaft seal Grundfos offers these seal arrangements: • single seal

86

Contra I50 HzTechnical data

Contra I Bloc-SUPER on stainless steel combi foot

Technical data

TM03

006

9 38

04

P2 [kW] n [min-1] IEC sizeOn stainless steel combi foot

lH Ø dH

0.55 1450 80 410 2200.75 1450 80 410 2200.75 2900 80 410 2201.1 2900 80 410 2201.1 1450 90S 410 2201.5 2900 90S 410 2201.5 1450 90L 410 2202.2 2900 90L 410 2202.2 1450 100L 480 2703.0 2900 100L 480 2704.0 2900 112M 520 2705.5 2900 112M 520 270

Dimensions depend on housing size (DNs, DNd, a1, f2, h2). See table of connections, page 34.

(2) Other sizes and special connections are available on request.(4) Largest diameter of pump without motor.

Page 87: GRUNDFOS DATA BOOKLET - Unopomp7 Euro-HYGIA® Sanitary pumps Materials Design variations See page 27. Mechanical shaft seal Grundfos offers these seal arrangements: • single seal

87

Page 88: GRUNDFOS DATA BOOKLET - Unopomp7 Euro-HYGIA® Sanitary pumps Materials Design variations See page 27. Mechanical shaft seal Grundfos offers these seal arrangements: • single seal

88

Contra II50 HzPerformance curves

Contra II2-pole

TM02

975

0 44

05

0 5 10 15 20 25 30 35 40 45 Q [m³/h]

0

10

20

30

40

50

60

70

80

90

100

110

120

130

140

150

160

H[m]

Contra II50 Hz

-1

-2

-3

-4

-5

0 5 10 15 20 25 30 35 40 45 Q [m³/h]

0

4

8

12

16

20

24

P2[kW]

-1

-2

-3

-4

-5

0 5 10 15 20 25 30 35 40 45 Q [m³/h]

25

30

35

40

45

50

55

60[%]Eta

-1

-2

-3

-4

-5

0 5 10 15 20 25 30 35 40 45 Q [m³/h]

0

1

2

3

4

5

6

7[m]

NPSH

0 2 4 6 8 10 12 14 Q [l/s]

-1

-2

-3-4

-5

Page 89: GRUNDFOS DATA BOOKLET - Unopomp7 Euro-HYGIA® Sanitary pumps Materials Design variations See page 27. Mechanical shaft seal Grundfos offers these seal arrangements: • single seal

Contra II50 HzTechnical data

Contra II Adapta® on cast iron foot

Technical data

TM03

007

0 38

04

P2 [kW] n [min-1] IEC sizeOn cast iron foot

b k3(1) u(1)

3.0 2900 100L - 320 1754.0 1450 112M - 340 1854.0 2900 112M - 340 1855.5 1450 132S 20 390 2055.5 2900 132S 20 390 2057.5 2900 132S 20 390 2057.5 1450 132M 20 420 20511.0 2900 160M 51 490 24015.0 2900 160M 51 490 24018.5 2900 160L 51 530 240

Dimensions depend on housing size (DNs, DNd, a1, f2, h2). See table of connections, page 37.

(1) Motor dimensions depend on make; motor dimensions show maximum size.(2) Other sizes and special connections are available on request.(4) Largest diameter of pump without motor.(7) N-Eupex coupling.

89

Page 90: GRUNDFOS DATA BOOKLET - Unopomp7 Euro-HYGIA® Sanitary pumps Materials Design variations See page 27. Mechanical shaft seal Grundfos offers these seal arrangements: • single seal

90

Contra II50 HzTechnical data

Contra II Adapta® SUPER on stainless steel combi foot(frame size 100 - 160)

Technical data

TM03

007

1 38

04

P2 [kW] n [min-1] IEC sizeOn stainless steel combi foot

lH hH Ø dH

3.0 2900 100L 510 240 4204.0 1450 112M 510 240 4204.0 2900 112M 510 240 4205.5 1450 132S 510 240 4205.5 2900 132S 510 240 4207.5 2900 132S 510 240 4207.5 1450 132M 510 240 42011.0 2900 160M 650 285 48515.0 2900 160M 650 285 48518.5 2900 160L 650 285 485

Dimensions depend on housing size (DNs, DNd, a1, f2, h2). See table of connections, page 37.

(2) Other sizes and special connections are available on request.(4) Largest diameter of pump without motor.(7) N-Eupex coupling.

Page 91: GRUNDFOS DATA BOOKLET - Unopomp7 Euro-HYGIA® Sanitary pumps Materials Design variations See page 27. Mechanical shaft seal Grundfos offers these seal arrangements: • single seal

Contra II50 HzTechnical data

Contra II Adapta®-V on stainless steel pedestal with/without suction elbow (frame size 100-160)

Technical data

TM03

007

2 38

04

Discharge port is asymmetric; the pump can be drained completely

For installing, removing and servicing the pump, lifting point should be arranged directly above the pump and removable lengths incorporated into the suction line.The discharge port is asymmetric; the pump can be drained completely.

P2 [kW] n [min-1] IEC sizeOn stainless steel pedestal with/without suction elbow

b k3(1) u(1)

2.2 1450 100L 0 320 1753.0 1450 100L 0 320 1753.0 2900 100L 0 320 1754.0 1450 112M 0 340 1854.0 2900 112M 0 340 1855.5 1450 132S 20 390 2055.5 2900 132S 20 390 2057.5 2900 132S 20 390 2057.5 1450 132M 20 420 20511.0 2900 160M 51 490 24015.0 2900 160M 51 490 24018.5 2900 160L 51 530 240

Dimensions depend on housing size (DNs, DNd, a1, f2, h2, h3, e1, e5). See table of connections, page 37.

(1) Motor dimensions depend on make; motor dimensions show maximum size.(2) Other sizes and special connections are available on request.(7) N-Eupex coupling.

91

Page 92: GRUNDFOS DATA BOOKLET - Unopomp7 Euro-HYGIA® Sanitary pumps Materials Design variations See page 27. Mechanical shaft seal Grundfos offers these seal arrangements: • single seal

92

Contra II50 HzTechnical data

Contra II Bloc on cast iron foot(frame size 90-132)

Technical data

TM03

007

3 38

04

P2 [kW] n [min-1] IEC sizeOn cast iron foot

k3(1) u(1)

0.75 1450 90S 282 1301.1 1450 90S 282 1301.5 1450 90L 282 1301.5 2900 90S 282 1302.2 2900 90L 282 1302.2 1450 100L 312 1633.0 1450 100L 312 1633.0 2900 100L 312 1634.0 2900 112M 335 1764.0 1450 112M 335 1765.5 2900 112M 371 1767.5 2900 132S 433 19611.0 2900 132M 433 196

Dimensions depend on housing size (DNs, DNd, a1, f2, h2). See table of connections, page 37.

(1) Motor dimensions depend on make; motor dimensions show maximum size.(2) Other sizes and special connections are available on request.(4) Largest diameter of pump without motor.

Page 93: GRUNDFOS DATA BOOKLET - Unopomp7 Euro-HYGIA® Sanitary pumps Materials Design variations See page 27. Mechanical shaft seal Grundfos offers these seal arrangements: • single seal

Contra II50 HzTechnical data

Contra II Bloc-SUPER on stainless steel combi foot(frame size 90-132)

Technical data

TM03

007

4 38

04

P2 [kW] n [min-1] IEC sizeOn stainless steel combi foot

l lH Ø dH

0.75 1450 90S 521 480 2701.1 1450 90S 521 480 2701.5 1450 90L 521 480 2701.5 2900 90S 521 480 2702.2 2900 90L 521 480 2702.2 1450 100L 521 480 2703.0 1450 100L 521 480 2703.0 2900 100L 521 480 2704.0 2900 112M 561 520 2704.0 1450 112M 561 520 2705.5 2900 112M 561 520 2707.5 2900 132S 641 600 32011.0 2900 132M 641 600 320

Dimensions depend on housing size (DNs, DNd, a1, f2, h2). See table of connections, page 37.

(2) Other sizes and special connections are available on request.(4) Largest diameter of pump without motor.

93

Page 94: GRUNDFOS DATA BOOKLET - Unopomp7 Euro-HYGIA® Sanitary pumps Materials Design variations See page 27. Mechanical shaft seal Grundfos offers these seal arrangements: • single seal

94

Contra II50 HzTechnical data

Contra II Bloc-SUPER on stainless steel combi foot(frame size 160)

Technical data

TM03

007

5 38

04M12

ø50

P2 [kW] n [min-1] IEC sizeOn stainless steel combi foot

l lH Ø dH

15.0 2900 160M 791 750 35018.5 2900 160L 791 750 350

Dimensions depend on housing size (DNs, DNd, a1, f2, h2). See table of connections, page 37.

(2) Other sizes and special connections are available on request.(4) Largest diameter of pump without motor.

Page 95: GRUNDFOS DATA BOOKLET - Unopomp7 Euro-HYGIA® Sanitary pumps Materials Design variations See page 27. Mechanical shaft seal Grundfos offers these seal arrangements: • single seal

95

Page 96: GRUNDFOS DATA BOOKLET - Unopomp7 Euro-HYGIA® Sanitary pumps Materials Design variations See page 27. Mechanical shaft seal Grundfos offers these seal arrangements: • single seal

96

durietta 050 HzPerformance curves

durietta 02-pole

durietta 04-pole

TM03

405

6 14

06

0 1 2 3 4 5 Q [m³/h]

0

10

20

30

40

50

60

70

H[m]

durietta 050 Hz

-1

-2

-3

-4

-5

-6

0 1 2 3 4 5 Q [m³/h]

0.0

0.4

0.8

1.2

1.6

2.0

P2[kW]

0.0 0.5 1.0 1.5 Q [l/s]

-1-2-3

-4

-5-6

TM03

405

7 14

06

0.0 0.5 1.0 1.5 2.0 2.5 3.0 3.5 Q [m³/h]

0.0

0.5

1.0

1.5

2.0

2.5

3.0

3.5

4.0

4.5

H[m]

durietta 050 Hz

-1

0.0 0.5 1.0 1.5 2.0 2.5 3.0 3.5 Q [m³/h]

0.18

0.19

0.20

0.21

0.22

0.23

P2[kW]

0.0 0.2 0.4 0.6 0.8 1.0 Q [l/s]

-1

Page 97: GRUNDFOS DATA BOOKLET - Unopomp7 Euro-HYGIA® Sanitary pumps Materials Design variations See page 27. Mechanical shaft seal Grundfos offers these seal arrangements: • single seal

durietta 050 HzTechnical data

durietta 0 K on motor foot

Technical data

TM03

378

5 10

06

P2 [kW] n [min-1] IEC size Stage D E F G H U Net weight [kg]

0.25 1500 71 1 90 45 71 112 212 102 100.37 3000 71 1 90 45 71 112 212 102 100.55 3000 71 1 90 45 71 112 212 102 100.55 3000 71 2 90 45 71 112 212 102 110.75 3000 71 2 90 45 71 112 212 102 110.75 3000 71 3 90 45 71 112 212 102 11.51.1 3000 80 3 100 50 80 125 240 123 131.1 3000 80 4 100 50 80 125 240 123 13.51.5 3000 90S 4 100 56 90 140 255 123 151.5 3000 90S 5 100 56 90 140 255 123 202.2 3000 90L 5 125 56 90 140 282 123 222.2 3000 90L 6 125 56 90 140 282 123 25

Dimensions depend on housing size (DNs, DNd, A, A’, B(1), B’(2), C, J, K). See table of connections, page 40.

(1) Add 37.5 mm for pumps with double mechanical seal

97

Page 98: GRUNDFOS DATA BOOKLET - Unopomp7 Euro-HYGIA® Sanitary pumps Materials Design variations See page 27. Mechanical shaft seal Grundfos offers these seal arrangements: • single seal

98

durietta 050 HzTechnical data

durietta 0 K SUPER on stainless steel combi foot

Technical data

TM03

378

4 10

06

P2 [kW] n [min-1] IEC size Stage D' E' F' G' H' U' I' L ±5Net

weight [kg]

0.25 1500 71 1 145 10 87 150 235 200 180 14 110.37 3000 71 1 145 10 87 150 235 200 180 14 110.55 3000 71 1 145 10 87 150 235 200 180 14 110.55 3000 71 2 145 10 87 150 235 200 180 14 120.75 3000 71 2 145 10 87 150 235 200 180 14 120.75 3000 71 3 145 10 87 150 235 200 200 14 131.1 3000 80 3 210 15 100 170 300 250 200 40 141.1 3000 80 4 210 15 100 170 300 250 200 40 151.5 3000 90 4 210 15 110 170 300 250 200 40 161.5 3000 90 5 210 15 110 170 300 250 200 40 172.2 3000 90 5 210 30 110 170 300 250 200 40 182.2 3000 90 6 210 30 110 170 300 250 200 40 19

Dimensions depend on housing size (DNs, DNd, A, A’, B(1), B’(2), C, J, K). See table of connections, page 40.

(2) Add 37.5 mm for pumps with double mechanical seal

Page 99: GRUNDFOS DATA BOOKLET - Unopomp7 Euro-HYGIA® Sanitary pumps Materials Design variations See page 27. Mechanical shaft seal Grundfos offers these seal arrangements: • single seal

durietta 050 HzTechnical data

durietta 0 K-V

Technical data

TM03

378

3 10

06

P2 [kW] n [min-1] IEC size Stage H'' U'' Net weight [kg]0.75 3000 71 1 243 123 100.75 3000 71 2 243 123 110.75 3000 71 3 243 123 121.5 3000 90S 3 243 123 12.51.5 3000 90S 4 243 123 131.5 3000 90S 5 243 133 142.2 3000 90L 5 269 133 152.2 3000 90L 6 269 133 16

Dimensions depend on housing size (DNs, DNd, A, A’, B(1), B’(2), C, J, K). See table of connections, page 40.

(1) Add 37.5 mm for pumps with double mechanical seal

99

Page 100: GRUNDFOS DATA BOOKLET - Unopomp7 Euro-HYGIA® Sanitary pumps Materials Design variations See page 27. Mechanical shaft seal Grundfos offers these seal arrangements: • single seal

100

SIPLA50 HzPerformance curves

SIPLA3.1 and 6.1, 4-pole

SIPLA12.1, 18.1 and 28.1, 4-pole

TM02

968

3 44

05S

IPLA

0 1 2 3 4 5 Q [m³/h]

0

5

10

15

20

25

30

35

40

H[m]

SIPLA50 Hz

3.16.1

0 1 2 3 4 5 Q [m³/h]

0.0

0.2

0.4

0.6

0.8

1.0

1.2

1.4

P2[kW]

3.1

6.1

0 1 2 3 4 5 Q [m³/h]

4

6

8

10

12

14

16

18

20

[%]Eta

0.0 0.5 1.0 1.5 Q [l/s]

3.1

6.1

TM02

968

5 44

05

0 4 8 12 16 20 24 Q [m³/h]

0

5

10

15

20

25

30

35

40

H[m]

SIPLA50 Hz

28.1

12.1

18.1

0 4 8 12 16 20 24 Q [m³/h]

0.0

0.5

1.0

1.5

2.0

2.5

3.0

3.5

4.0

4.5

P2[kW]

28.1

12.1

18.1

0 4 8 12 16 20 24 Q [m³/h]

10

12

14

16

18

20

22

24

26

28

30

[%]Eta

0 2 4 6 Q [l/s]

28.1

12.1

18.1

Page 101: GRUNDFOS DATA BOOKLET - Unopomp7 Euro-HYGIA® Sanitary pumps Materials Design variations See page 27. Mechanical shaft seal Grundfos offers these seal arrangements: • single seal

SIPLA50 HzPerformance curves

SIPLA52.1, 65.1 and 90.1, 4-pole

TM02

968

9 44

05

0 10 20 30 40 50 60 70 Q [m³/h]

0

10

20

30

40

50

60

H[m]

SIPLA50 Hz

65.152.1

90.1

0 10 20 30 40 50 60 70 Q [m³/h]

0

2

4

6

8

10

12

14

16

18

P2[kW]

65.1

52.1

90.1

0 10 20 30 40 50 60 70 Q [m³/h]

5

10

15

20

25

30

35

[%]Eta

0 5 10 15 20 Q [l/s]

65.1

52.1

90.1

101

Page 102: GRUNDFOS DATA BOOKLET - Unopomp7 Euro-HYGIA® Sanitary pumps Materials Design variations See page 27. Mechanical shaft seal Grundfos offers these seal arrangements: • single seal

102

SIPLA50 HzTechnical data

SIPLA Adapta® on cast iron foot

Technical data

TM02

965

5 36

04

Pump type

DNs/DNd

a lPump Motor On cast iron foot

e l5 l6IEC size

P2 [kW] k3 Size w1 m2 n1 n2 s1/s2 h1 h2 l7

3.1 32 145 563 100 40 108 80M 0.55 234 I 105 220 250 215 24/14 200 150 2213.1 32 145 598 100 40 108 80M 0.75 269 I 105 220 250 215 24/14 200 150 2216.1/12.1

40 161 640 120 56 137 90L 1.5 282 I 105 220 250 215 24/14 200 150 221

6.1/12.1

40 161 691 120 56 137 100L 2.2 313 I 105 220 250 215 24/14 200 150 241

18.1 50 174 734 170 52 158 100L 3.0 313 II 122 220 250 215 24/14 225 170 26318.1 50 174 755 170 52 158 112M 4.0 334 II 122 220 250 215 24/14 225 170 26328.1 65 178 762 170 56 165 112M 4.0 334 II 122 220 250 215 24/14 225 170 26328.1 65 178 822 170 56 165 132S 5.5 374 II 122 220 250 215 24/14 225 170 28352.1 65 178 836 170 56 179 132M 7.5 374 II 122 220 250 215 24/14 225 200 28352.1 65 178 971 170 56 179 160M 11.0 478 II 122 220 250 215 24/14 225 200 31465.1 80 204 1170 240 68 221 160M 11.0 478 III 136 220 270 220 17.5 225 200 47165.1 80 204 1170 240 68 221 160L 15.0 478 III 136 220 270 220 17.5 225 200 47190.1 80 204 1300 240 68 227 180M 18.5 602 III 136 220 270 220 17.5 225 200 47190.1 80 204 1300 240 68 227 180L 22.0 602 III 136 220 270 220 17.5 225 200 471

Page 103: GRUNDFOS DATA BOOKLET - Unopomp7 Euro-HYGIA® Sanitary pumps Materials Design variations See page 27. Mechanical shaft seal Grundfos offers these seal arrangements: • single seal

SIPLA50 HzTechnical data

SIPLA Adapta® SUPER on combi foot

Technical data

TM02

965

6 36

04

Pump type

DNs/DNd

a l h1 h2 h3

Pump Motor AD On combi foot Shroud

e l5 l6IEC size

P2 [kW] Size l7' Size m2 n2 Size p k3'

3.1 32 138 682 200 150 380 100 40 108 80M 0.55 I 204 I 300 260 1.1 320 3703.1 32 138 682 200 150 380 100 40 108 80M 0.75 I 204 I 300 260 1.1 320 3706.1/12.1

40 154 711 200 150 380 120 56 137 90L 1.5 I 204 I 300 260 1.1 320 370

6.1/12.1

40 154 851 200 150 410 120 56 137 100L 2.2 I 204 II 404 300 1.2 370 460

18.1 50 167 914 220 170 460 170 52 158 100L 3.0 II 246 II 404 300 2.2 420 51018.1 50 167 914 220 170 460 170 52 158 112M 4.0 II 246 II 404 300 2.2 420 51028.1 65 171 921 220 170 460 170 56 165 112M 4.0 II 246 II 404 300 2.2 420 51028.1 65 171 921 220 170 460 170 56 165 132S 5.5 II 246 II 404 300 2.2 420 51052.1 65 171 935 220 200 460 170 56 179 132M 7.5 II 246 II 404 300 2.2 420 51052.1 65 171 1075 220 200 503 170 56 179 160M 11.0 II 245 II 404 300 2.3 485 650

103

Page 104: GRUNDFOS DATA BOOKLET - Unopomp7 Euro-HYGIA® Sanitary pumps Materials Design variations See page 27. Mechanical shaft seal Grundfos offers these seal arrangements: • single seal

104

SIPLA50 HzTechnical data

SIPLA Bloc on motor foot

Technical data

TM02

965

7 36

04

Pump type

DNs/DNd

a l o h2

Pump Motor

e l5 l6IEC size

P2 [kW] h1 k3 m2 n1 n2 s1 w1

3.1 32 90 342 30 150 100 40 108 80M 0.55 80 234 100 150 125 9.5 503.1 32 90 377 30 150 100 40 108 80M 0.75 80 269 100 150 125 9.5 506.1/12.1

40 134 464 10 150 120 56 137 100L 1.5 100 327 140 196 160 12 78

6.1/12.1

40 134 450 10 150 120 56 137 100L 2.2 100 327 140 196 160 12 78

18.1 50 130 485 35 170 170 52 158 100L 3.0 100 327 140 196 160 12 7818.1 50 142 511 35 170 170 52 158 112M 4.0 112 353 140 226 190 12 9028.1 65 146 518 23 170 170 56 165 112M 4.0 112 353 140 226 190 12 9052.1 65 145 553 28 200 170 56 179 132M 7.5 132 374 178 256 216 12 8965.1 80 176 699 25 200 240 68 221 160L 11.0 160 478 254 300 254 15 10865.1 80 176 699 25 200 240 68 221 160L 15.0 160 478 254 300 254 15 10890.1 80 189 829 25 200 240 68 227 180M 18.5 180 602 241 339 279 15 12190.1 80 189 829 25 200 240 68 227 180L 22.0 180 602 279 339 279 15 121

Page 105: GRUNDFOS DATA BOOKLET - Unopomp7 Euro-HYGIA® Sanitary pumps Materials Design variations See page 27. Mechanical shaft seal Grundfos offers these seal arrangements: • single seal

SIPLA50 HzTechnical data

SIPLA Bloc-SUPER on stainless steel ball feet

Technical data

TM02

965

8 36

04

Pump type DNs/DNd h1 h2 l n m

Pump Motor Shroude l6' a c IEC size P2 [kW] p k3'

3.1 32 155 150 508 200 220 100 98 0 67 80M 0.55 224 4103.1 32 155 150 508 200 220 100 98 0 67 80M 0.75 224 410

6.1/12.1 40 200 150 608 220 255 120 128 7 74 100L 1.5 274 4806.1/12.1 40 200 150 608 220 255 120 128 7 74 100L 2.2 274 480

18.1 50 200 170 628 225 280 170 148 23 83 100L 3.0 274 48018.1 50 200 170 628 225 280 170 148 23 83 112M 4.0 274 48028.1 65 200 170 634 225 280 170 154 22 87 112M 4.0 274 48052.1 65 200 200 768 225 300 170 168 23 100 132M 7.5 324 60065.1 80 200 200 858 225 400 240 208 24 129 160L 11.0 374 65065.1 80 200 200 858 225 400 240 208 24 129 160L 15.0 374 65090.1 80 200 200 864 225 400 240 214 21 138 180M 18.5 374 65090.1 80 200 200 864 225 400 240 214 21 138 180L 22.0 374 650

105

Page 106: GRUNDFOS DATA BOOKLET - Unopomp7 Euro-HYGIA® Sanitary pumps Materials Design variations See page 27. Mechanical shaft seal Grundfos offers these seal arrangements: • single seal

106

MAXA50 HzPerformance curves

MAXA 80-160/XXX2-pole

MAXA 80-160/XXX4-pole

TM02

972

2 44

05

0 20 40 60 80 100 120 140 160 180 Q [m³/h]

0

5

10

15

20

25

30

35

40

45

H[m]

MAXA 80-16050 Hz

/159/166

/173

/180

/187

0 20 40 60 80 100 120 140 160 180 Q [m³/h]

0

5

10

15

20

P2[kW]

/159/166

/173

/180

/187

0 20 40 60 80 100 120 140 160 180 Q [m³/h]

45

50

55

60

65

70

75

[%]Eta

/159/166

/173

/180

/187

0 20 40 60 80 100 120 140 160 180 Q [m³/h]

0

2

4

6

8

[m]NPSH

0 10 20 30 40 50 Q [l/s]

/159/166

/173

/180/187

TM02

972

7 44

05

0 10 20 30 40 50 60 70 80 90 100 Q [m³/h]

0

1

2

3

4

5

6

7

8

9

10

11

H[m]

MAXA 80-16050 Hz

/166/173

/180/187

0 10 20 30 40 50 60 70 80 90 100 Q [m³/h]

0.0

0.5

1.0

1.5

2.0

2.5

P2[kW]

/166

/173

/180

/187

0 10 20 30 40 50 60 70 80 90 100 Q [m³/h]

45

50

55

60

65

70

75

[%]Eta

/166/173

/180

/187

0 10 20 30 40 50 60 70 80 90 100 Q [m³/h]

0

1

2

3

4

5

6

[m]NPSH

0 5 10 15 20 25 30 Q [l/s]

/187

/180

/173

/166

Page 107: GRUNDFOS DATA BOOKLET - Unopomp7 Euro-HYGIA® Sanitary pumps Materials Design variations See page 27. Mechanical shaft seal Grundfos offers these seal arrangements: • single seal

MAXA50 HzPerformance curves

MAXA 80-200/XXX2-pole

MAXA 80-200/XXX4-pole

TM02

972

3 44

05

0 20 40 60 80 100120140160180200 Q [m³/h]

0

10

20

30

40

50

60

70

H[m]

MAXA 80-20050 Hz

/180

/190

/200

/210

/220

/228

0 20 40 60 80 100120140160180200 Q [m³/h]

0

10

20

30

40

P2[kW]

/180/190

/200

/210

/220/228

0 20 40 60 80 100120140160180200 Q [m³/h]

45

50

55

60

65

70

75

[%]Eta

/180

/190

/200/210

/220

/228

0 20 40 60 80 100120140160180200 Q [m³/h]

0

1

2

3

4

5

6

[m]NPSH

0 10 20 30 40 50 60 Q [l/s]

/180 /190

/200

/210

/220

/228

TM02

972

8 44

05

0 20 40 60 80 100 120 Q [m³/h]

0

2

4

6

8

10

12

14

16

18

H[m]

MAXA 80-20050 Hz

/180 /190/200

/210/220/228

0 20 40 60 80 100 120 Q [m³/h]

0

1

2

3

4

5

P2[kW]

/180/190

/200

/210

/220/228

0 20 40 60 80 100 120 Q [m³/h]

25

30

35

40

45

50

55

60

65[%]Eta

/180 /190 /200/210

/220

/228

0 20 40 60 80 100 120 Q [m³/h]

0

1

2

3

4

5

6

[m]NPSH

0 10 20 30 Q [l/s]

/180

/190

/200

/210

/220 /228

107

Page 108: GRUNDFOS DATA BOOKLET - Unopomp7 Euro-HYGIA® Sanitary pumps Materials Design variations See page 27. Mechanical shaft seal Grundfos offers these seal arrangements: • single seal

108

MAXA50 HzPerformance curves

MAXA 80-250/XXX2-pole

MAXA 80-250/XXX4-pole

TM02

972

4 44

05

0 20 40 60 80 100120140160180200 Q [m³/h]

20

30

40

50

60

70

80

90

100

110

H[m]

MAXA 80-25050 Hz

/220/230

/240

/250

/260/268

0 20 40 60 80 100120140160180200 Q [m³/h]

10

20

30

40

50

60

P2[kW]

/220

/230/240

/250

/260

/268

0 20 40 60 80 100120140160180200 Q [m³/h]

45

50

55

60

65

70

75

[%]Eta

/220

/230/240/250/260

/268

0 20 40 60 80 100120140160180200 Q [m³/h]

0

2

4

6

8

[m]NPSH

0 10 20 30 40 50 60 Q [l/s]

/220

/230

/240 /250

/260

/268

TM02

972

9 44

05

0 20 40 60 80 100 120 Q [m³/h]

0

2

4

6

8

10

12

14

16

18

20

22

24

26

H[m]

MAXA 80-25050 Hz

/220

/230

/240

/250

/260/268

0 20 40 60 80 100 120 Q [m³/h]

0

2

4

6

8

10

P2[kW]

/220/230/240/250/260/268

0 20 40 60 80 100 120 Q [m³/h]

45

50

55

60

65

70

75

[%]Eta

/220/230

/240/250

/260

/268

0 20 40 60 80 100 120 Q [m³/h]

0

1

2

3

4

5

6

[m]NPSH

0 10 20 30 Q [l/s]

/220/230/240/250/260/268

Page 109: GRUNDFOS DATA BOOKLET - Unopomp7 Euro-HYGIA® Sanitary pumps Materials Design variations See page 27. Mechanical shaft seal Grundfos offers these seal arrangements: • single seal

MAXA50 HzPerformance curves

MAXA 80-315/XXX4-pole

TM02

973

0 44

05

0 20 40 60 80 100 120 140 Q [m³/h]

10

15

20

25

30

35

40

H[m]

MAXA 80-31550 Hz

/270

/285

/300

/315

/330

/343

0 20 40 60 80 100 120 140 Q [m³/h]

0

4

8

12

16

20

P2[kW]

/270/285

/300/315

/330/343

0 20 40 60 80 100 120 140 Q [m³/h]

40

45

50

55

60

65

70

[%]Eta

/270 /285

/300 /315

/330

/343

0 20 40 60 80 100 120 140 Q [m³/h]

0

1

2

3

4

5

6

[m]NPSH

0 10 20 30 40 Q [l/s]

/270

/285

/300

/315

/330

/343

109

Page 110: GRUNDFOS DATA BOOKLET - Unopomp7 Euro-HYGIA® Sanitary pumps Materials Design variations See page 27. Mechanical shaft seal Grundfos offers these seal arrangements: • single seal

110

MAXA50 HzPerformance curves

MAXA 100-200/XXX2-pole

MAXA 100-200/XXX4-pole

TM02

972

5 44

05

0 40 80 120 160 200 240 280 320 Q [m³/h]

0

10

20

30

40

50

60

70

H[m]

MAXA 100-20050 Hz

/185

/195 /205/215

/225

/234

0 40 80 120 160 200 240 280 320 Q [m³/h]

0

10

20

30

40

50

P2[kW]

/185/195

/205/215

/225

/234

0 40 80 120 160 200 240 280 320 Q [m³/h]

50

55

60

65

70

75

80

[%]Eta

/185

/195

/205

/215/225

/234

0 40 80 120 160 200 240 280 320 Q [m³/h]

0

1

2

3

4

5

6

[m]NPSH

0 20 40 60 80 Q [l/s]

/185

/195 /205

/215

/225

/234

TM02

973

1 44

05

0 20 40 60 80 100 120 140 Q [m³/h]

0

2

4

6

8

10

12

14

16

18

H[m]

MAXA 100-20050 Hz

/185 /195/205

/215

/225

/234

0 20 40 60 80 100 120 140 Q [m³/h]

0

1

2

3

4

5

6

P2[kW]

/185/195

/205

/215

/225

/234

0 20 40 60 80 100 120 140 Q [m³/h]

45

50

55

60

65

70

75

80[%]Eta

/185

/195/205

/215

/225

/234

0 20 40 60 80 100 120 140 Q [m³/h]

0

1

2

3

4

5

6

[m]NPSH

0 10 20 30 40 Q [l/s]

/185

/195

/205

/215 /225/234

Page 111: GRUNDFOS DATA BOOKLET - Unopomp7 Euro-HYGIA® Sanitary pumps Materials Design variations See page 27. Mechanical shaft seal Grundfos offers these seal arrangements: • single seal

MAXA50 HzPerformance curves

MAXA 100-250/XXX2-pole

MAXA 100-250/XXX4-pole

TM02

972

6 44

05

0 40 80 120 160 200 240 280 Q [m³/h]

0

10

20

30

40

50

60

70

80

90

100

H[m]

MAXA 100-25050 Hz

/215

/225

/235

/245

/255

/267

0 40 80 120 160 200 240 280 Q [m³/h]

0

20

40

60

80

P2[kW]

/215/225/235/245

/255

/267

0 40 80 120 160 200 240 280 Q [m³/h]

50

55

60

65

70

75

80

[%]Eta

/215

/225

/235

/245

/255/267

0 40 80 120 160 200 240 280 Q [m³/h]

0

1

2

3

4

5

[m]NPSH

0 20 40 60 80 Q [l/s]

/215

/225

/235

/245

/255

/267

TM02

973

2 44

05

0 20 40 60 80 100 120 140 160 Q [m³/h]

0

2

4

6

8

10

12

14

16

18

20

22

24

26

H[m]

MAXA 100-25050 Hz

/215

/225

/235

/245

/255

/267

0 20 40 60 80 100 120 140 160 Q [m³/h]

0

2

4

6

8

10

P2[kW]

/215/225/235/245/255

/267

0 20 40 60 80 100 120 140 160 Q [m³/h]

45

50

55

60

65

70

75

80[%]Eta

/215

/225

/235/245

/255

/267

0 20 40 60 80 100 120 140 160 Q [m³/h]

0

1

2

3

4

5

6

[m]NPSH

0 10 20 30 40 50 Q [l/s]

/215/225

/235 /245/255

/267

111

Page 112: GRUNDFOS DATA BOOKLET - Unopomp7 Euro-HYGIA® Sanitary pumps Materials Design variations See page 27. Mechanical shaft seal Grundfos offers these seal arrangements: • single seal

112

MAXA50 HzPerformance curves

MAXA 125-250/XXX4-pole

MAXA 125-315/XXX4-pole

TM02

973

3 44

05

0 40 80 120 160 200 240 Q [m³/h]

0

2

4

6

8

10

12

14

16

18

20

22

24

26

28

H[m]

MAXA 125-25050 Hz

/220 /230/245

/260

/275

/290

0 40 80 120 160 200 240 Q [m³/h]

0

4

8

12

16

P2[kW]

/220/230

/245

/260

/275

/290

0 40 80 120 160 200 240 Q [m³/h]

40

45

50

55

60

65

70

75[%]Eta

/220

/230

/245

/260

/275/290

0 40 80 120 160 200 240 Q [m³/h]

0

1

2

3

4

5

[m]NPSH

0 20 40 60 Q [l/s]

/220 /230

/245 /260

/275/290

TM02

973

4 44

05

0 40 80 120 160 200 240 Q [m³/h]

0

5

10

15

20

25

30

35

40

45

H[m]

MAXA 125-31550 Hz

/295

/310

/325

/340

/353

0 40 80 120 160 200 240 Q [m³/h]

0

10

20

30

40

P2[kW]

/295/310/325

/340

/353

0 40 80 120 160 200 240 Q [m³/h]

45

50

55

60

65

70

75

80[%]Eta

/295

/310/325

/340/353

0 40 80 120 160 200 240 Q [m³/h]

0

1

2

3

4

5

6

7[m]

NPSH

0 20 40 60 Q [l/s]

/295/310/325

/340

/353

Page 113: GRUNDFOS DATA BOOKLET - Unopomp7 Euro-HYGIA® Sanitary pumps Materials Design variations See page 27. Mechanical shaft seal Grundfos offers these seal arrangements: • single seal

MAXA50 HzPerformance curves

MAXA 150-250/XXX4-pole

MAXA 150-315/XXX4-pole

TM02

973

5 44

05

0 50 100 150 200 250 300 350 400Q [m³/h]

0

2

4

6

8

10

12

14

16

18

20

22

24

26

28

30

H[m]

MAXA 150-25050 Hz

/240/250

/265/280

/296

0 50 100 150 200 250 300 350 400Q [m³/h]

0

5

10

15

20

25

30

P2[kW]

/240/250

/265

/280

/296

0 50 100 150 200 250 300 350 400Q [m³/h]

45

50

55

60

65

70

75

80[%]Eta

/240 /250/265

/280

/296

0 50 100 150 200 250 300 350 400Q [m³/h]

0

1

2

3

4

5

6

7[m]

NPSH

0 25 50 75 100 Q [l/s]

/240

/250

/265

/280/296

TM02

973

6 44

05

0 50 100 150 200 250 300 350 400 Q [m³/h]

0

5

10

15

20

25

30

35

40

45

H[m]

MAXA 150-31550 Hz

/300

/315

/330

/345

/359

0 50 100 150 200 250 300 350 400 Q [m³/h]

0

10

20

30

40

50

P2[kW]

/300/315

/330

/345

/359

0 50 100 150 200 250 300 350 400 Q [m³/h]

45

50

55

60

65

70

75

80[%]Eta

/300

/315

/330

/345/359

0 50 100 150 200 250 300 350 400 Q [m³/h]

0

1

2

3

4

5

6

7[m]

NPSH

0 25 50 75 100 125 Q [l/s]

/300

/315

/330/345

/359

113

Page 114: GRUNDFOS DATA BOOKLET - Unopomp7 Euro-HYGIA® Sanitary pumps Materials Design variations See page 27. Mechanical shaft seal Grundfos offers these seal arrangements: • single seal

114

MAXA50 HzPerformance curves

MAXA 150-400/XXX4-pole

MAXA 200-400/XXX4-pole

TM02

973

7 44

05

0 50 100 150 200 250 300 350 400 Q [m³/h]

10

15

20

25

30

35

40

45

50

55

60

65

70

H[m]

MAXA 150-40050 Hz

/340

/360

/380

/400

/420

/435

0 50 100 150 200 250 300 350 400 Q [m³/h]

0

20

40

60

80

100

P2[kW]

/340/360

/380

/400

/420/435

0 50 100 150 200 250 300 350 400 Q [m³/h]

40

45

50

55

60

65

70

75[%]Eta

/340

/360

/380/400

/420

/435

0 50 100 150 200 250 300 350 400 Q [m³/h]

0

1

2

3

4

5

6

[m]NPSH

0 25 50 75 100 125 Q [l/s]

/340 /360

/380/400

/420/435

TM02

973

8 44

05

0 100 200 300 400 500 600 700 800 Q [m³/h]

0

5

10

15

20

25

30

35

40

45

50

55

H[m]

MAXA 200-40050 Hz

/345

/370

/408

/420

0 100 200 300 400 500 600 700 800 Q [m³/h]

20

30

40

50

60

70

80

P2[kW]

/345

/370

/408

/420

0 100 200 300 400 500 600 700 800 Q [m³/h]

50

55

60

65

70

75

80

85[%]Eta

/345

/370

/408

/420

0 100 200 300 400 500 600 700 800 Q [m³/h]

3

4

5

6

7

8

9

[m]NPSH

0 50 100 150 200 Q [l/s]

/345

/370/420

Page 115: GRUNDFOS DATA BOOKLET - Unopomp7 Euro-HYGIA® Sanitary pumps Materials Design variations See page 27. Mechanical shaft seal Grundfos offers these seal arrangements: • single seal

MAXA L50 HzTechnical data

MAXA L

Technical data, 2-pole

TM02

965

3 36

04

Pumpsize P2 [kW] IEC size k3

(1) a1 f3 h2 p3 p4 p5 DNs(2) DNd

(2) p6 u(1) w1 h1 m1 m2 n1 n2 h9 s1 Net weight [kg]

80-160

11.0 160M 490 125 218 225 150 157 185

100(125.150)

80(100)

350 240 108 160 210 256 300 254 18 15 11815.0 160M 490 125 218 225 150 157 185 350 240 108 160 210 256 300 254 18 15 13118.5 160L 530 125 218 225 150 157 185 350 240 108 160 254 300 300 254 18 15 14822.0 180M 605 125 218 225 150 157 185 350 265 121 180 241 287 339 279 18 15 164

80-200

15.0 160M 490 125 220 250 170 171 205 350 240 108 160 210 256 300 254 18 15 16618.5 160L 530 125 220 250 170 171 205 350 240 108 160 254 300 300 254 18 15 18322.0 180M 605 125 220 250 170 171 205 350 265 121 180 241 287 339 279 18 15 19930.0 200L 665 125 220 250 170 171 205 400 310 133 200 305 355 388 318 24 19 24937.0 200L 665 125 220 250 170 171 205 400 310 133 200 305 355 388 318 24 19 272

80-25030.0 200L 665 125 220 280 180 189 220 400 310 133 200 305 355 388 318 24 19 26437.0 200L 665 125 220 280 180 189 220 400 310 133 200 305 355 388 318 24 19 287

100-200

18.5 160L 530 125 220 280 170 171 205

125(150)

100(125)

350 240 108 160 254 300 300 254 18 15 19622.0 180M 605 125 220 280 170 171 205 350 265 121 180 241 287 339 279 18 15 21230.0 200L 665 125 220 280 170 171 205 400 310 133 200 305 355 388 318 24 19 26237.0 200L 665 125 220 280 170 171 205 400 310 133 200 305 355 388 318 24 19 285

(1) Motor dimensions depend on make; motor dimensions show maximum size.(2) Flange dimensions are according to DIN EN 1092-1 (DIN 2632). Nominal diameter in parenthesis are available on request.

115

Page 116: GRUNDFOS DATA BOOKLET - Unopomp7 Euro-HYGIA® Sanitary pumps Materials Design variations See page 27. Mechanical shaft seal Grundfos offers these seal arrangements: • single seal

116

MAXA L50 HzTechnical data

Technical data, 4-pole

TM03

014

2 41

04

* This drawing applies to pump size 80-160, only.For pump sizes 80-200 to 125-250, see previous page.

Pumpsize P2 [kW] IEC size k3

(1) a1 f3 h2 p3 p4 p5 DNs(2) DNd

(2) p6 u(1) w1 h1 m1 m2 n1 n2 h9 s1 Net weight [kg]

80-160*3.0 100L 320 125 168.5 225 150 157 185

100(125,150)

80(100)

250 175 52 180 - - - - - - 774.0 112M 340 125 168.5 225 150 157 185 250 185 52 180 - - - - - - 82

80-2005.5 132S 390 125 200 250 170 171 205 300 205 89 132 140 180 256 216 15 12 1167.5 132M 420 125 200 250 170 171 205 300 205 89 132 178 218 256 216 15 12 129

80-2505.5 132S 390 125 200 280 180 189 220 300 205 89 132 140 180 256 216 15 12 1237.5 132M 420 125 200 280 180 189 220 300 205 89 132 178 218 256 216 15 12 13611.0 160M 490 125 220 280 180 189 220 350 240 108 160 210 256 300 254 18 15 163

80-315

5.5 132S 390 125 200 315 208 215 225 300 205 89 132 140 180 256 216 15 12 1367.5 132M 420 125 200 315 208 215 225 300 205 89 132 178 218 256 216 15 12 14911.0 160M 490 125 220 315 208 215 225 350 240 108 160 210 256 300 254 18 15 17615.0 160L 530 125 220 315 208 215 225 350 240 108 160 254 300 300 254 18 15 19318.5 180M 605 125 220 315 208 215 225 350 265 121 180 241 287 339 279 18 15 26722.0 180L 605 125 220 315 208 215 225 350 265 121 180 279 325 339 279 18 15 282

100-2005.5 132S 390 125 200 280 170 171 205

125(150)

100(125)

300 205 89 132 140 180 256 216 15 12 1237.5 132M 420 125 200 280 170 171 205 300 205 89 132 178 218 256 216 15 12 136

100-250

5.5 132S 390 140 200 280 180 189 220 300 205 89 132 140 180 256 216 15 12 1317.5 132M 420 140 200 280 180 189 220 300 205 89 132 178 218 256 216 15 12 14411.0 160M 490 140 220 280 180 189 220 350 240 108 160 210 256 300 254 18 15 17115.0 160L 530 140 220 280 180 189 220 350 240 108 160 254 300 300 254 18 15 188

100-315

7.5 132M 420 140 200 315 208 215 255 300 205 89 132 178 218 256 216 15 12 16611.0 160M 490 140 220 315 208 215 255 350 240 108 160 210 256 300 254 18 15 19315.0 160L 530 140 220 315 208 215 255 350 240 108 160 254 300 300 254 18 15 21018.5 180M 605 140 220 315 208 215 255 350 265 121 180 241 287 339 279 18 15 28422.0 180L 605 140 220 315 208 215 255 350 265 121 180 279 325 339 279 18 15 29930.0 200L 665 140 220 315 208 215 255 400 310 133 200 305 355 388 318 24 19 366

125-250

7.5 132M 420 140 200 355 200 206 260

150(200)

125(150)

300 205 89 132 178 218 256 216 15 12 16011.0 160M 490 140 220 355 200 206 260 350 240 108 160 210 256 300 254 18 15 18715.0 160L 530 140 220 355 200 206 260 350 240 108 160 254 300 300 254 18 15 20418.5 180M 605 140 220 355 200 206 260 350 265 121 180 241 287 339 279 18 15 27822.0 180L 605 140 220 355 200 206 260 350 265 121 180 279 325 339 279 18 15 293

(1) Motor dimensions depend on make; motor dimensions show maximum size.(2) Flange dimensions are according to DIN EN 1092-1 (DIN 2632).(3) Nominal diameter in parenthesis are available on request.(6) Pumps fitted with motors of IEC size 100 and 112 are supported with pump foot and motor foot; from IEC size 132 pumps are fitted with motor foot, only.

Page 117: GRUNDFOS DATA BOOKLET - Unopomp7 Euro-HYGIA® Sanitary pumps Materials Design variations See page 27. Mechanical shaft seal Grundfos offers these seal arrangements: • single seal

MAXA CN50 HzTechnical data

MAXA CN

Technical data, 2-pole

TM02

965

4 36

04

Pumpsize P2 [kW] IEC size k3

(1) l5 E(7) f1 a1 h1 h2 h7 Ø d Ø d4 DNs(2) DNd

(2) a2 l1 l2 l3 b1 b2 b3 d5Baseplatesize

Net weight

[kg]

80-160

11.0 160M 600 559 74 360 125 180 225 290 24 42

100(125.150)

80(100)

75 1250 205 840 480 590 540 24 6 21215.0 160M 600 559 74 360 125 180 225 290 24 42 75 1250 205 840 480 590 540 24 6 22518.5 160L 640 559 74 360 125 180 225 290 24 42 75 1250 205 840 480 590 540 24 6 24022.0 180M 715 665 80 360 125 180 225 290 24 48 75 1250 205 840 480 590 540 24 6 25530.0 200L 775 573 88 360 125 180 225 310 24 55 75 1250 205 840 480 590 540 24 6 305

80-200

15.0 160M 600 669 74 470 125 180 250 290 32 42 75 1250 205 840 480 590 540 24 6 23518.5 160L 640 669 74 470 125 180 250 290 32 42 75 1250 205 840 480 590 540 24 6 25022.0 180M 715 676 80 470 125 180 250 290 32 48 75 1250 205 840 480 590 540 24 6 26530.0 200L 775 683 88 470 125 180 250 310 32 55 75 1250 205 840 480 590 540 24 6 31537.0 200L 775 683 88 470 125 180 250 310 32 55 75 1250 205 840 480 590 540 24 6 33845.0 225M 840 683 88 470 125 180 250 365 32 55 75 1600 270 1060 580 710 650 28 7 542

80-250

30.0 200L 775 683 88 470 125 200 280 310 32 55 90 1250 205 840 480 590 540 24 6 33037.0 200L 775 683 88 470 125 200 280 310 32 55 90 1250 205 840 480 590 540 24 6 35345.0 225M 840 683 88 470 125 200 280 365 32 55 90 1600 270 1060 580 710 650 28 7 55755.0 250M 930 697 102 470 125 200 280 390 32 60 90 1600 270 1060 580 710 650 28 7 66275.0 280S 1040 697 102 470 125 200 280 420 32 65 90 1800 300 1200 650 780 720 28 8 86190.0 280M 1040 697 102 470 125 200 280 420 32 65 90 1800 300 1200 650 780 720 28 8 901

100-200

18.5 160L 640 669 74 470 125 200 280 310 32 42

125(150)

100(125)

90 1250 205 840 480 590 540 24 6 26322.0 180M 715 676 80 470 125 200 280 310 32 48 90 1250 205 840 480 590 540 24 6 27830.0 200L 775 683 88 470 125 200 280 310 32 55 90 1250 205 840 480 590 540 24 6 32837.0 200L 775 683 88 470 125 200 280 310 32 55 90 1250 205 840 480 590 540 24 6 35145.0 225M 840 683 88 470 125 200 280 365 32 55 90 1600 270 1060 580 710 650 28 7 55555.0 250M 930 697 102 470 125 200 280 390 32 60 90 1600 270 1060 580 710 650 28 7 66075.0 280S 1040 697 102 470 125 200 280 420 32 65 90 1800 300 1200 650 780 720 28 8 859

100-250

30.0 200L 775 698 88 470 140 225 280 335 32 55 90 1250 205 840 480 590 540 24 6 33937.0 200L 775 698 88 470 140 225 280 335 32 55 90 1250 205 840 480 590 540 24 6 36245.0 225M 840 698 88 470 140 225 280 365 32 55 90 1600 270 1060 580 710 650 28 7 56655.0 250M 930 712 102 470 140 225 280 390 32 60 90 1600 270 1060 580 710 650 28 7 67175.0 280S 1040 712 102 470 140 225 280 420 32 65 90 1800 300 1200 650 780 720 28 8 87090.0 280M 1040 712 102 470 140 225 280 420 32 65 90 1800 300 1200 650 780 720 28 8 910

117

Page 118: GRUNDFOS DATA BOOKLET - Unopomp7 Euro-HYGIA® Sanitary pumps Materials Design variations See page 27. Mechanical shaft seal Grundfos offers these seal arrangements: • single seal

118

MAXA CN50 HzTechnical data

Technical data, 4-pole

To be continued on the next page.

Pumpsize P2 [kW] IEC size k3

(1) l5 E(7) f1 a1 h1 h2 h7 Ø d Ø d4 DNs(2) DNd

(2) a2 l1 l2 l3 b1 b2 b3 d5Baseplatesize

Net weight

[kg]

80-1603.0 100L 380 543 58 360 125 180 225 282 24 28

100(125.150)

80(100)

75 1120 190 740 430 540 490 24 5 1424.0 112M 400 543 58 360 125 180 225 282 24 28 75 1120 190 740 430 540 490 24 5 147

80-200

2.2 100L 380 653 58 470 125 180 250 282 32 28 75 1120 190 740 430 540 490 24 5 1653.0 100L 380 653 58 470 125 180 250 282 32 28 75 1120 190 740 430 540 490 24 5 1684.0 112M 400 653 58 470 125 180 250 282 32 28 75 1120 190 740 430 540 490 24 5 1725.5 132S 470 663 68 470 125 180 250 282 32 38 75 1120 190 740 430 540 490 24 5 183

80-250

4.0 112M 400 653 58 470 125 200 280 310 32 28 90 1250 205 840 480 590 540 24 6 1955.5 132S 470 663 68 470 125 200 280 310 32 38 90 1250 205 840 480 590 540 24 6 2067.5 132M 500 663 68 470 125 200 280 310 32 38 90 1250 205 840 480 590 540 24 6 21811.0 160M 600 669 74 470 125 200 280 310 32 42 90 1250 205 840 480 590 540 24 6 239

80-315

5.5 132S 470 663 68 470 125 250 315 360 32 38 90 1250 205 840 480 590 540 24 6 2187.5 132M 500 663 68 470 125 250 315 360 32 38 90 1250 205 840 480 590 540 24 6 23211.0 160M 600 669 74 470 125 250 315 360 32 42 90 1250 205 840 480 590 540 24 6 25315.0 160L 640 669 74 470 125 250 315 360 32 42 90 1250 205 840 480 590 540 24 6 27018.5 180M 715 675 80 470 125 250 315 360 32 48 90 1250 205 840 480 590 540 24 6 34422.0 180L 715 675 80 470 125 250 315 360 32 48 90 1250 205 840 480 590 540 24 6 358

100-200

3.0 100L 380 653 58 470 125 200 280 302 32 28

125(150)

100(125)

90 1120 190 740 430 540 490 24 5 1524.0 112M 400 653 58 470 125 200 280 302 32 28 90 1120 190 740 430 540 490 24 5 1795.5 132S 470 663 68 470 125 200 280 302 32 38 90 1120 190 740 430 540 490 24 5 1917.5 132M 500 663 68 470 125 200 280 302 32 38 90 1120 190 740 430 540 490 24 5 203

100-250

4.0 112M 400 668 58 470 140 225 280 335 32 28 90 1250 205 840 480 590 540 24 6 2025.5 132S 470 678 68 470 140 225 280 335 32 38 90 1250 205 840 480 590 540 24 6 2147.5 132M 500 678 68 470 140 225 280 335 32 38 90 1250 205 840 480 590 540 24 6 22611.0 160M 600 684 74 470 140 225 280 335 32 42 90 1250 205 840 480 590 540 24 6 24715.0 160L 640 684 74 470 140 225 280 335 32 42 90 1250 205 840 480 590 540 24 6 260

100-315

7.5 132M 500 678 68 470 140 250 315 360 32 38 90 1250 205 840 480 590 540 24 6 24811.0 160M 600 684 74 470 140 250 315 360 32 42 90 1250 205 840 480 590 540 24 6 26915.0 160L 640 684 74 470 140 250 315 360 32 42 90 1250 205 840 480 590 540 24 6 28718.5 180M 715 690 80 470 140 250 315 360 32 48 90 1250 205 840 480 590 540 24 6 36022.0 180L 715 690 80 470 140 250 315 360 32 48 90 1250 205 840 480 590 540 24 6 37530.0 200L 775 698 88 470 140 250 315 360 32 55 90 1250 205 840 480 590 540 24 6 435

125-250

7.5 132M 500 678 68 470 140 250 355 360 32 38

150(200)

125(150)

90 1250 205 840 480 590 540 24 6 24311.0 160M 600 684 74 470 140 250 355 360 32 42 90 1250 205 840 480 590 540 24 6 26315.0 160L 640 684 74 470 140 250 355 360 32 42 90 1250 205 840 480 590 540 24 6 28118.5 180M 715 690 80 470 140 250 355 360 32 48 90 1250 205 840 480 590 540 24 6 355

125-315

11.0 160M 600 744 74 530 140 280 355 420 42 42 110 1600 270 1060 580 710 650 28 7 38615.0 160L 640 744 74 530 140 280 355 420 42 42 110 1600 270 1060 580 710 650 28 7 40318.5 180M 715 750 80 530 140 280 355 420 42 48 110 1600 270 1060 580 710 650 28 7 48022.0 180L 715 750 80 530 140 280 355 420 42 48 110 1600 270 1060 580 710 650 28 7 49630.0 200L 775 758 88 530 140 280 355 420 42 55 110 1600 270 1060 580 710 650 28 7 55937.0 225S 840 772 102 530 140 280 355 420 42 60 110 1600 270 1060 580 710 650 28 7 621

Page 119: GRUNDFOS DATA BOOKLET - Unopomp7 Euro-HYGIA® Sanitary pumps Materials Design variations See page 27. Mechanical shaft seal Grundfos offers these seal arrangements: • single seal

MAXA CN50 HzTechnical data

Continued from previous page .

Pumpsize P2 [kW] IEC size k3

(1) l5 E(7) f1 a1 h1 h2 h7 Ø d Ø d4 DNs(2) DNd

(2) a2 l1 l2 l3 b1 b2 b3 d5Baseplatesize

Net weight

[kg]

150-250

11.0 160M 600 764 74 530 160 280 375 420 42 42

200(250)

150

110 1600 270 1060 580 710 650 28 7 36715.0 160L 640 764 74 530 160 280 375 420 42 42 110 1600 270 1060 580 710 650 28 7 38318.5 180M 715 770 80 530 160 280 375 420 42 48 110 1600 270 1060 580 710 650 28 7 45822.0 180L 715 770 80 530 160 280 375 420 42 48 110 1600 270 1060 580 710 650 28 7 47330.0 200L 775 778 88 530 160 280 375 420 42 55 110 1600 270 1060 580 710 650 28 7 533

150-315

15.0 160L 640 764 74 530 160 280 400 420 42 42 110 1800 300 1200 650 780 720 28 8 50018.5 180M 715 770 80 530 160 280 400 420 42 48 110 1800 300 1200 650 780 720 28 8 52522.0 180L 715 770 80 530 160 280 400 420 42 48 110 1800 300 1200 650 780 720 28 8 54030.0 200L 775 778 88 530 160 280 400 420 42 55 110 1800 300 1200 650 780 720 28 8 60037.0 225S 840 792 102 530 160 280 400 420 42 60 110 1800 300 1200 650 780 720 28 8 66045.0 225M 840 792 102 530 160 280 400 420 42 60 110 1800 300 1200 650 780 720 28 8 69055.0 250M 930 792 102 530 160 280 400 420 42 65 110 1800 300 1200 650 780 720 28 8 795

150-400

30.0 200L 775 778 88 530 160 315 450 455 42 55 110 1800 300 1200 650 780 720 28 8 65737.0 225S 840 792 102 530 160 315 450 455 42 60 110 1800 300 1200 650 780 720 28 8 71745.0 225M 840 792 102 530 160 315 450 455 42 60 110 1800 300 1200 650 780 720 28 8 74755.0 250M 930 792 102 530 160 315 450 455 42 65 110 1800 300 1200 650 780 720 28 8 85275.0 280S 1040 806 116 530 160 315 450 455 42 75 110 1800 300 1200 650 780 720 28 8 103290.0 280M 1040 806 116 530 160 315 450 455 42 75 110 1800 300 1200 650 780 720 28 8 1090

200-400

30.0 200L 775 814 88 551 175 315 530 455 42 55

200

110 1800 300 1200 650 780 720 28 8 68737.0 225S 840 828 102 551 175 315 530 455 42 60 110 1800 300 1200 650 780 720 28 8 74745.0 225M 840 828 102 551 175 315 530 455 42 60 110 1800 300 1200 650 780 720 28 8 77755.0 250M 930 828 102 551 175 315 530 455 42 65 110 1800 300 1200 650 780 720 28 8 88275.0 280S 1040 842 116 551 175 315 530 455 42 75 110 1800 300 1200 650 780 720 28 8 106290.0 280M 1040 842 116 551 175 315 530 455 42 75 110 1800 300 1200 650 780 720 28 8 1120

(1) Motor dimensions depend on make; motor dimensions show maximum size.(2) Flange dimensions are according to DIN EN 1092-1 (DIN 2632).(3) Nominal diameter in parenthesis are available on request.(7) Coupling of our choice.

Larger motors, threaded pipe connections and special flanges are available on request.

119

Page 120: GRUNDFOS DATA BOOKLET - Unopomp7 Euro-HYGIA® Sanitary pumps Materials Design variations See page 27. Mechanical shaft seal Grundfos offers these seal arrangements: • single seal

120

MAXANA50 HzPerformance curves

MAXANA 32-160/XXX2-pole

MAXANA 32-160/XXX4-pole

TM02

969

9 44

05

0 4 8 12 16 20 24 28 32 Q [m³/h]

0

5

10

15

20

25

30

35

40

45

H[m]

MAXANA 32-16050 Hz

/140

/150

/160

/170

/180

0 4 8 12 16 20 24 28 32 Q [m³/h]

0

1

2

3

4

5

P2[kW]

/140/150

/160

/170

/180

0 4 8 12 16 20 24 28 32 Q [m³/h]

30

35

40

45

50

55

60

[%]Eta

/140 /150

/160/170

/180

0 4 8 12 16 20 24 28 32 Q [m³/h]

0

2

4

6

8

[m]NPSH

0 2 4 6 8 10 Q [l/s]

/140

/150/160

/170

/180

TM02

971

0 44

05

0 2 4 6 8 10 12 14 16 18 20 22 Q [m³/h]

0

1

2

3

4

5

6

7

8

9

10

11

H[m]

MAXANA 32-16050 Hz

/140

/150

/160/170

/180

0 2 4 6 8 10 12 14 16 18 20 22 Q [m³/h]

0.0

0.1

0.2

0.3

0.4

0.5

0.6

0.7

P2[kW]

/140

/150

/160/170

/180

0 2 4 6 8 10 12 14 16 18 20 22 Q [m³/h]

25

30

35

40

45

50

[%]Eta

/140

/150

/160

/170

/180

0 2 4 6 8 10 12 14 16 18 20 22 Q [m³/h]

0

1

2

3

4

5

6

[m]NPSH

0 1 2 3 4 5 6 Q [l/s]

/140 /150/160

/170

/180

Page 121: GRUNDFOS DATA BOOKLET - Unopomp7 Euro-HYGIA® Sanitary pumps Materials Design variations See page 27. Mechanical shaft seal Grundfos offers these seal arrangements: • single seal

MAXANA50 HzPerformance curves

MAXANA 32-200/XXX2-pole

MAXANA 32-200/XXX4-pole

TM02

970

0 44

05

0 5 10 15 20 25 30 35 40 Q [m³/h]

0

10

20

30

40

50

60

70

H[m]

MAXANA 32-20050 Hz

/170

/180

/190

/200

/210

/220

0 5 10 15 20 25 30 35 40 Q [m³/h]

0

2

4

6

8

10

12

P2[kW]

/170

/180

/190

/200/210/220

0 5 10 15 20 25 30 35 40 Q [m³/h]

30

35

40

45

50

55

[%]Eta

/170

/180

/190/200/210/220

0 5 10 15 20 25 30 35 40 Q [m³/h]

0

2

4

6

8

[m]NPSH

0 2 4 6 8 10 Q [l/s]

/170

/180

/190

/200

/210

/220

TM02

971

1 44

05

0 4 8 12 16 20 24 28 32 Q [m³/h]

2

4

6

8

10

12

14

16

H[m]

MAXANA 32-20050 Hz

/170 /180/190

/200

/210/220

0 4 8 12 16 20 24 28 32 Q [m³/h]

0.0

0.4

0.8

1.2

1.6

2.0

P2[kW]

/170/180

/190

/200

/210

/220

0 4 8 12 16 20 24 28 32 Q [m³/h]

25

30

35

40

45

50

55

[%]Eta

/170

/180

/190

/200/210

/220

0 4 8 12 16 20 24 28 32 Q [m³/h]

0

1

2

3

4

5

6

[m]NPSH

0 2 4 6 8 Q [l/s]

/180

/170

/190 /200

/210

/220

121

Page 122: GRUNDFOS DATA BOOKLET - Unopomp7 Euro-HYGIA® Sanitary pumps Materials Design variations See page 27. Mechanical shaft seal Grundfos offers these seal arrangements: • single seal

122

MAXANA50 HzPerformance curves

MAXANA 40-160/XXX2-pole

MAXANA 40-160/XXX4-pole

TM02

970

1 44

05

0 5 10 15 20 25 30 35 40 Q [m³/h]

0

5

10

15

20

25

30

35

40

45

H[m]

MAXANA 40-16050 Hz

/140

/150

/160

/170

/180

0 5 10 15 20 25 30 35 40 Q [m³/h]

0

1

2

3

4

5

6

P2[kW]

/140

/150

/160/170

/180

0 5 10 15 20 25 30 35 40 Q [m³/h]

40

45

50

55

60

65

70

[%]Eta

/140

/150 /160

/170

/180

0 5 10 15 20 25 30 35 40 Q [m³/h]

0

2

4

6

8

[m]NPSH

0 2 4 6 8 10 12 Q [l/s]

/140

/150

/160 /170

/180

TM02

971

2 44

05

0 4 8 12 16 20 24 28 32 Q [m³/h]

0

1

2

3

4

5

6

7

8

9

10

11

H[m]

MAXANA 40-16050 Hz

/140 /150

/160

/170 /180

0 4 8 12 16 20 24 28 32 Q [m³/h]

0.0

0.2

0.4

0.6

0.8

1.0

P2[kW]

/140/150/160/170

/180

0 4 8 12 16 20 24 28 32 Q [m³/h]

35

40

45

50

55

60

65

[%]Eta

/140

/150

/160

/170

/180

0 4 8 12 16 20 24 28 32 Q [m³/h]

0

1

2

3

4

[m]NPSH

0 2 4 6 8 Q [l/s]

/180/170

/160/150

/140

Page 123: GRUNDFOS DATA BOOKLET - Unopomp7 Euro-HYGIA® Sanitary pumps Materials Design variations See page 27. Mechanical shaft seal Grundfos offers these seal arrangements: • single seal

MAXANA50 HzPerformance curves

MAXANA 40-200/XXX2-pole

MAXANA 40-200/XXX4-pole

TM02

970

2 44

05

0 5 10 15 20 25 30 35 40 45 50 Q [m³/h]

10

15

20

25

30

35

40

45

50

55

60

65

70

H[m]

MAXANA 40-20050 Hz

/170

/180

/190

/200

/210

/220

0 5 10 15 20 25 30 35 40 45 50 Q [m³/h]

0

4

8

12

16

P2[kW]

/170/180

/190/200/210/220

0 5 10 15 20 25 30 35 40 45 50 Q [m³/h]

30

35

40

45

50

55

60

[%]Eta

/170

/180

/190/200

/210/220

0 5 10 15 20 25 30 35 40 45 50 Q [m³/h]

0

2

4

6

8

[m]NPSH

0 2 4 6 8 10 12 14 Q [l/s]

/170/180

/190

/200

/210/220

TM02

971

3 44

05

0 4 8 12 16 20 24 28 32 Q [m³/h]

0

2

4

6

8

10

12

14

16

18

H[m]

MAXANA 40-20050 Hz

/170

/180 /190

/200

/210

/220

0 4 8 12 16 20 24 28 32 Q [m³/h]

0.0

0.4

0.8

1.2

1.6

2.0

P2[kW]

/170

/180

/190

/200

/210/220

0 4 8 12 16 20 24 28 32 Q [m³/h]

30

35

40

45

50

55

60

[%]Eta

/170

/180

/190

/200

/210

/220

0 4 8 12 16 20 24 28 32 Q [m³/h]

0

2

4

6

8

[m]NPSH

0 2 4 6 8 10 Q [l/s]

/180/170

/190

/200

/210

/220

123

Page 124: GRUNDFOS DATA BOOKLET - Unopomp7 Euro-HYGIA® Sanitary pumps Materials Design variations See page 27. Mechanical shaft seal Grundfos offers these seal arrangements: • single seal

124

MAXANA50 HzPerformance curves

MAXANA 50-125/XXX2-pole

MAXANA 50-125/XXX4-pole

TM02

970

3 44

05

0 10 20 30 40 50 60 70 Q [m³/h]

0

5

10

15

20

25

30

H[m]

MAXANA 50-12550 Hz

/115

/125

/135

/145

0 10 20 30 40 50 60 70 Q [m³/h]

0

1

2

3

4

5

P2[kW]

/115

/125

/135

/145

0 10 20 30 40 50 60 70 Q [m³/h]

40

45

50

55

60

65

70

[%]Eta

/115/125

/135

/145

0 10 20 30 40 50 60 70 Q [m³/h]

0

2

4

6

8

[m]NPSH

0 5 10 15 20 Q [l/s]

/115

/125

/135/145

TM02

971

4 44

05

0 5 10 15 20 25 30 35 40 Q [m³/h]

0

1

2

3

4

5

6

7

H[m]

MAXANA 50-12550 Hz

/115

/125

/135

/145

0 5 10 15 20 25 30 35 40 Q [m³/h]

0.0

0.1

0.2

0.3

0.4

0.5

0.6

0.7

P2[kW]

/115

/125

/135

/145

0 5 10 15 20 25 30 35 40 Q [m³/h]

25

30

35

40

45

50

55

60[%]Eta

/115 /125

/135

/145

0 5 10 15 20 25 30 35 40 Q [m³/h]

1.2

1.4

1.6

1.8

2.0

2.2

2.4

[m]NPSH

0 2 4 6 8 10 Q [l/s]

/145/135

/125

/115

Page 125: GRUNDFOS DATA BOOKLET - Unopomp7 Euro-HYGIA® Sanitary pumps Materials Design variations See page 27. Mechanical shaft seal Grundfos offers these seal arrangements: • single seal

MAXANA50 HzPerformance curves

MAXANA 50-160/XXX2-pole

MAXANA 50-160/XXX4-pole

TM02

970

4 44

05

0 10 20 30 40 50 60 70 Q [m³/h]

0

5

10

15

20

25

30

35

40

45

50

H[m]

MAXANA 50-16050 Hz

/140

/150

/160

/170

/180

0 10 20 30 40 50 60 70 Q [m³/h]

0

2

4

6

8

10

P2[kW]

/140

/150/160

/170

/180

0 10 20 30 40 50 60 70 Q [m³/h]

40

45

50

55

60

65

70

[%]Eta

/140

/150

/160

/170

/180

0 10 20 30 40 50 60 70 Q [m³/h]

0

2

4

6

8

[m]NPSH

0 5 10 15 20 Q [l/s]

/140

/150/160

/170/180

TM02

971

5 44

05

0 5 10 15 20 25 30 35 40 45 Q [m³/h]

0

1

2

3

4

5

6

7

8

9

10

11

12

H[m]

MAXANA 50-16050 Hz

/140/150

/160/170

/180

0 5 10 15 20 25 30 35 40 45 Q [m³/h]

0.0

0.2

0.4

0.6

0.8

1.0

1.2

1.4

P2[kW]

/140

/150

/160

/170

/180

0 5 10 15 20 25 30 35 40 45 Q [m³/h]

35

40

45

50

55

60

65

70[%]Eta

/140/150

/160

/170

/180

0 5 10 15 20 25 30 35 40 45 Q [m³/h]

0

1

2

3

4

5

[m]NPSH

0 2 4 6 8 10 12 14 Q [l/s]

/170

/160/150

/140

/180

125

Page 126: GRUNDFOS DATA BOOKLET - Unopomp7 Euro-HYGIA® Sanitary pumps Materials Design variations See page 27. Mechanical shaft seal Grundfos offers these seal arrangements: • single seal

126

MAXANA50 HzPerformance curves

MAXANA 50-200/XXX2-pole

MAXANA 50-200/XXX4-pole

TM02

970

5 44

05

0 10 20 30 40 50 60 70 80 Q [m³/h]

10

20

30

40

50

60

70

H[m]

MAXANA 50-20050 Hz

/170

/180

/190

/200

/210

/220

0 10 20 30 40 50 60 70 80 Q [m³/h]

0

4

8

12

16

20

P2[kW]

/170

/180/190/200/210/220

0 10 20 30 40 50 60 70 80 Q [m³/h]

40

45

50

55

60

65

70

[%]Eta

/170/180/190/200

/210

/220

0 10 20 30 40 50 60 70 80 Q [m³/h]

0

2

4

6

8

[m]NPSH

0 5 10 15 20 Q [l/s]

/170

/180/190/200/210

/220

TM02

971

6 44

05

0 10 20 30 40 50 60 Q [m³/h]

0

2

4

6

8

10

12

14

16

18

H[m]

MAXANA 50-20050 Hz

/170 /180

/190/200

/210

/220

0 10 20 30 40 50 60 Q [m³/h]

0.0

0.5

1.0

1.5

2.0

2.5

3.0

P2[kW]

/170

/180

/190

/200

/210/220

0 10 20 30 40 50 60 Q [m³/h]

35

40

45

50

55

60

65

[%]Eta

/170 /180

/190

/200

/210

/220

0 10 20 30 40 50 60 Q [m³/h]

0

2

4

6

8

[m]NPSH

0 5 10 15 Q [l/s]

/170

/180/190

/200

/210

/220

Page 127: GRUNDFOS DATA BOOKLET - Unopomp7 Euro-HYGIA® Sanitary pumps Materials Design variations See page 27. Mechanical shaft seal Grundfos offers these seal arrangements: • single seal

MAXANA50 HzPerformance curves

MAXANA 65-125/XXX2-pole

TM02

970

6 44

05

0 20 40 60 80 100 120 Q [m³/h]

0

5

10

15

20

25

30

H[m]

MAXANA 65-12550 Hz

/155

0 20 40 60 80 100 120 Q [m³/h]

0

2

4

6

8

10

P2[kW]

/155

0 20 40 60 80 100 120 Q [m³/h]

30

35

40

45

50

55

60

[%]Eta

/155

0 20 40 60 80 100 120 Q [m³/h]

0

2

4

6

8

[m]NPSH

0 10 20 30 Q [l/s]

/155

127

Page 128: GRUNDFOS DATA BOOKLET - Unopomp7 Euro-HYGIA® Sanitary pumps Materials Design variations See page 27. Mechanical shaft seal Grundfos offers these seal arrangements: • single seal

128

MAXANA50 HzPerformance curves

MAXANA 65-160/XXX2-pole

MAXANA 65-160/XXX4-pole

TM02

970

7 17

06

0 20 40 60 80 100 120 Q [m³/h]

0

5

10

15

20

25

30

35

40

45

50

H[m]

MAXANA 65-16050 Hz

/140

/150

/160

/170

/180

0 20 40 60 80 100 120 Q [m³/h]

0

4

8

12

16

P2[kW]

/140

/150

/160

/170

/180

0 20 40 60 80 100 120 Q [m³/h]

35

40

45

50

55

60

65

[%]Eta

/140

/150

/160/170

/180

0 20 40 60 80 100 120 Q [m³/h]

0

2

4

6

8

[m]NPSH

0 10 20 30 Q [l/s]

/140 /150/160/170

/180

TM02

971

7 17

06

0 10 20 30 40 50 60 70 Q [m³/h]

0

1

2

3

4

5

6

7

8

9

10

11

H[m]

MAXANA 65-16050 Hz

/140 /150 /160/170

/180

0 10 20 30 40 50 60 70 Q [m³/h]

0.0

0.5

1.0

1.5

2.0

2.5

P2[kW]

/140/150

/160

/170

/180

0 10 20 30 40 50 60 70 Q [m³/h]

30

35

40

45

50

55

60

[%]Eta

/140/150

/160

/170

/180

0 10 20 30 40 50 60 70 Q [m³/h]

0

1

2

3

4

[m]NPSH

0 5 10 15 20 Q [l/s]

/160/150/140

/170

/180

Page 129: GRUNDFOS DATA BOOKLET - Unopomp7 Euro-HYGIA® Sanitary pumps Materials Design variations See page 27. Mechanical shaft seal Grundfos offers these seal arrangements: • single seal

MAXANA50 HzPerformance curves

MAXANA 65-200/XXX2-pole

MAXANA 65-200/XXX4-pole

TM02

970

8 44

05

0 20 40 60 80 100 120 140 Q [m³/h]

0

10

20

30

40

50

60

70

H[m]

MAXANA 65-20050 Hz

/170

/180

/190

/200/210

/220

0 20 40 60 80 100 120 140 Q [m³/h]

0

5

10

15

20

25

30

P2[kW]

/170

/180

/190

/200

/210

/220

0 20 40 60 80 100 120 140 Q [m³/h]

30

35

40

45

50

55

60

[%]Eta

/170/180

/190/200/210/220

0 20 40 60 80 100 120 140 Q [m³/h]

0

1

2

3

4

5

[m]NPSH

0 10 20 30 40 Q [l/s]

/170/180 /190

/200

/210

/220

TM02

971

8 44

05

0 10 20 30 40 50 60 70 80 90 Q [m³/h]

0

2

4

6

8

10

12

14

16

18

H[m]

MAXANA 65-20050 Hz

/170/180

/190/200

/210

/220

0 10 20 30 40 50 60 70 80 90 Q [m³/h]

0

1

2

3

4

P2[kW]

/170/180

/190

/200

/210

/220

0 10 20 30 40 50 60 70 80 90 Q [m³/h]

20

25

30

35

40

45

50

55[%]Eta

/170

/180 /190

/200/210

/220

0 10 20 30 40 50 60 70 80 90 Q [m³/h]

0

2

4

6

8

[m]NPSH

0 5 10 15 20 25 Q [l/s]

/180/170

/190/200

/210

/220

129

Page 130: GRUNDFOS DATA BOOKLET - Unopomp7 Euro-HYGIA® Sanitary pumps Materials Design variations See page 27. Mechanical shaft seal Grundfos offers these seal arrangements: • single seal

130

MAXANA50 HzPerformance curves

MAXANA 65-250/XXX2-pole

MAXANA 65-250/XXX4-pole

TM02

970

9 44

05

0 20 40 60 80 100 120 140 160 Q [m³/h]

0

10

20

30

40

50

60

70

80

90

100

110

H[m]

MAXANA 65-25050 Hz

/210

/225

/240

/255

/268

0 20 40 60 80 100 120 140 160 Q [m³/h]

0

10

20

30

40

50

P2[kW]

/210/225/240

/255

/268

0 20 40 60 80 100 120 140 160 Q [m³/h]

40

45

50

55

60

65

70

75[%]Eta

/210

/225

/240

/255/268

0 20 40 60 80 100 120 140 160 Q [m³/h]

0

1

2

3

4

5

6

7[m]

NPSH

0 10 20 30 40 Q [l/s]

/210

/225/240

/255/268

TM02

971

9 44

05

0 10 20 30 40 50 60 70 80 90 100110 Q [m³/h]

0

2

4

6

8

10

12

14

16

18

20

22

24

26

H[m]

MAXANA 65-25050 Hz

/210

/225

/240

/255

/268

0 10 20 30 40 50 60 70 80 90 100110 Q [m³/h]

0

1

2

3

4

5

6

7

P2[kW]

/210

/225

/240

/255

/268

0 10 20 30 40 50 60 70 80 90 100110 Q [m³/h]

35

40

45

50

55

60

65

70[%]Eta

/210 /225

/240/255

/268

0 10 20 30 40 50 60 70 80 90 100110 Q [m³/h]

0

1

2

3

4

5

[m]NPSH

0 5 10 15 20 25 30 Q [l/s]

/210

/225

/240

/255

/268

Page 131: GRUNDFOS DATA BOOKLET - Unopomp7 Euro-HYGIA® Sanitary pumps Materials Design variations See page 27. Mechanical shaft seal Grundfos offers these seal arrangements: • single seal

MAXANA Adapta®

50 HzTechnical data

MAXANA Adapta® on stainless steel foot

Technical data

TM02

965

2 36

04

Pumpsize P2 [kW] IEC size k3 u(1) a1 h2 p(4) b DNs

(6) DNd(6) Net weight

[kg]

32-1603.0 100L 320 175 80 160 264 0

50(65)

32(40)

714.0 112M 340 185 80 160 264 0 785.5 132S 390 205 80 160 264 20 90

32-200

3.0 100L 320 175 80 180 316 0 774.0 112M 340 185 80 180 316 0 845.5 132S 390 205 80 180 316 20 967.5 132S 390 205 80 180 316 20 10611.0 160M 490 240 80 180 316 51 12715.0 160M 490 240 80 180 316 51 138

40-160

4.0 112M 340 195 80 160 264 0

65(80)

40(50)

795.5 132S 390 205 80 160 264 20 917.5 132S 390 205 80 160 264 20 10111.0 160M 490 240 80 160 264 51 140

40-2007.5 132S 390 205 100 180 316 20 10711.0 160M 490 290 100 180 316 51 12615.0 160M 490 290 100 180 316 51 139

50-125

3.0 100L 320 175 100 160 264 0

50(65)

764.0 112M 340 185 100 160 264 0 835.5 132S 390 205 100 160 264 20 957.5 132S 390 205 100 160 264 20 105

50-160

5.5 132S 390 205 100 180 288 20 937.5 132S 390 205 100 180 288 20 10311.0 160M 490 240 100 180 288 51 11515.0 160M 490 240 100 180 288 51 135

50-20011.0 160M 490 240 100 200 316 51 12915.0 160M 490 240 100 200 316 51 142

65-1254.0 112M 340 185 100 180 288 0

80(100)

65(80)

865.5 132S 390 205 100 180 288 20 987.5 132S 390 205 100 180 288 20 108

65-160

5.5 132S 390 205 100 200 308 20 987.5 132S 390 205 100 200 308 20 10811.0 160M 490 240 100 200 308 51 12715.0 160M 490 240 100 200 308 51 140

65-20011.0 160M 490 240 100 225 348 51 13415.0 160M 490 240 100 225 348 51 147

Dimensions depend on housing size (DNs, DNd, a1, h2). See table of connections, page 44.

(1) Motor dimensions depend on make; motor dimensions show maximum size.(2) Flange dimensions are according to DIN EN 1092-1 (DIN 2632). Nominal diameter in parenthesis are available on request.(4) Largest diameter of pump without motor.(7) N-Eupex coupling.

131

Page 132: GRUNDFOS DATA BOOKLET - Unopomp7 Euro-HYGIA® Sanitary pumps Materials Design variations See page 27. Mechanical shaft seal Grundfos offers these seal arrangements: • single seal

132

MAXANA Adapta®

50 HzTechnical data

MAXANA Adapta® on Adapta® foot

Technical data

TM03

018

3 44

04

100

250

390

Pumpsize P2 [kW] n [min-1] IEC size b k3

(1) u(1)

65-250

15.0 2900 160M - 490 24018.5 2900 160L - 530 24022.0 2900 180L - 605 26530.0 2900 200L 25 665 31037.0 2900 200L 25 665 31045.0 2900 225M 30 700 330

(1) Motor dimensions depend on make; motor dimensions show maximum size.(2) Other sizes and special connections are available on request.(7) N-Eupex coupling.

Page 133: GRUNDFOS DATA BOOKLET - Unopomp7 Euro-HYGIA® Sanitary pumps Materials Design variations See page 27. Mechanical shaft seal Grundfos offers these seal arrangements: • single seal

MAXANA Bloc50 HzTechnical data

MAXANA Bloc on pump and motor foot

Technical data, 2-pole

TM03

020

2 45

04

250

1Pumpsize

P2 [kW]

IEC size k3

(1) u(1) a1 h1 h2 p(4) m1 m2 n1 n2 b DNs(2) DNd

(2)Net

weight [kg]

32-160

2.2 90L 285 150 80 132 160 264 100 70 240 190 50

50(65)

32(40)

343.0 100L 320 175 80 132 160 264 100 70 240 190 50 404.0 112M 340 185 80 132 160 264 100 70 240 190 50 475.5 112M 340 185 80 132 160 264 100 70 240 190 50 59

32-2003.0 100L 320 175 80 160 180 316 100 70 240 190 50 464.0 112M 340 185 80 160 180 316 100 70 240 190 50 535.5 112M 340 185 80 160 180 316 100 70 240 190 50 65

40-1604.0 112M 340 185 80 132 160 264 100 70 240 190 50

65(80)

40(50)

485.5 112M 340 185 80 132 160 264 100 70 240 190 50 60

50-1253.0 100L 320 175 100 132 160 264 100 70 240 190 50

50(65)

454.0 112M 340 185 100 132 160 264 100 70 240 190 50 525.5 112M 340 185 100 132 160 264 100 70 240 190 50 64

50-160 5.5 112M 340 185 100 160 180 288 100 70 265 212 50 62

65-1254.0 112M 340 185 100 160 180 288 125 95 280 212 65

80(100)

65(80)

555.5 112M 340 185 100 160 180 288 125 95 280 212 65 67

65-160 5.5 112M 340 185 100 160 200 308 125 95 280 212 65 67

133

Page 134: GRUNDFOS DATA BOOKLET - Unopomp7 Euro-HYGIA® Sanitary pumps Materials Design variations See page 27. Mechanical shaft seal Grundfos offers these seal arrangements: • single seal

134

MAXANA Bloc50 HzTechnical data

Technical data, 4-pole

Pumpsize

P2 [kW]

IEC size k3

(1) u(1) a1 h1 h2 p(4) m1 m2 n1 n2 b DNs(2) DNd

(2)Net

weight [kg]

32-1600.55 80 245 145 80 132 160 264 100 70 240 190 50

50(65)

32(40)

270.75 90S 285 150 80 132 160 264 100 70 240 190 50 28

32-2000.75 90S 285 150 80 160 180 316 100 70 240 190 50 341.1 90S 285 150 80 160 180 316 100 70 240 190 50 371.5 90L 285 150 80 160 180 316 100 70 240 190 50 40

40-160

0.55 80 245 145 80 132 160 264 100 70 240 190 50

65(80)

40(50)

280.75 90S 285 150 80 132 160 264 100 70 240 190 50 291.1 90S 285 150 80 132 160 264 100 70 240 190 50 321.5 90L 285 150 80 132 160 264 100 70 240 190 50 35

40-2001.1 90S 285 150 100 160 180 316 100 70 265 212 50 381.5 90L 285 150 100 160 180 316 100 70 265 212 50 412.2 100L 320 175 100 160 180 316 100 70 265 212 50 48

50-1250.55 80 245 145 100 132 160 264 100 70 240 190 50

50(65)

320.75 90S 285 150 100 132 160 264 100 70 240 190 50 331.1 90S 285 150 100 132 160 264 100 70 240 190 50 36

50-1601.1 90S 285 150 100 160 180 288 100 70 265 212 50

40(50)

341.5 90L 285 150 100 160 180 288 100 70 265 212 50 382.2 100L 320 175 100 160 180 288 100 70 265 212 50 44

50-200

1.5 90L 285 150 100 160 200 316 100 70 265 212 50 442.2 100L 320 175 100 160 200 316 100 70 265 212 50 513.0 100L 320 175 100 160 200 316 100 70 265 212 50 534.0 112M 340 185 100 160 200 316 100 70 265 212 50 58

65-1250.75 90S 285 150 100 160 180 288 125 95 280 212 65

80(100)

65(80)

361.1 90S 285 150 100 160 180 288 125 95 280 212 65 39

65-160

0.75 90S 285 150 100 160 200 308 125 95 280 212 65 361.1 90S 285 150 100 160 200 308 125 95 280 212 65 391.5 90L 285 150 100 160 200 308 125 95 280 212 65 432.2 100L 320 175 100 160 200 308 125 95 280 212 65 493.0 100L 320 175 100 160 200 308 125 95 280 212 65 51

65-200

1.5 90L 285 150 100 180 225 348 125 95 320 250 65 502.2 100L 320 175 100 180 225 348 125 95 320 250 65 563.0 100L 320 175 100 180 225 348 125 95 320 250 65 584.0 112M 340 185 100 180 225 348 125 95 320 250 65 635.5 112M 340 185 100 180 225 348 125 95 320 250 65 76

Dimensions depend on housing size (DNs, DNd, a1, h2). See table of connections, page 44.

(1) Motor dimensions depend on make; motor dimensions show maximum size.(2) Flange dimensions are according to DIN EN 1092-1 (DIN 2632). Nominal diameter in parenthesis are available on request.(4) Largest diameter of pump without motor.

Page 135: GRUNDFOS DATA BOOKLET - Unopomp7 Euro-HYGIA® Sanitary pumps Materials Design variations See page 27. Mechanical shaft seal Grundfos offers these seal arrangements: • single seal

MAXANA Bloc50 HzTechnical data

MAXANA Bloc on motor foot

Technical data

TM03

020

1 45

04250

Pumpsize P2 [kW] IEC

size a1 h1 h2 p m1 m2 n1 n2 h9 s1 DNs(2) DNd

(2)Net

weight [kg]

32-2007.5 132S 80 132 180 316 180 140 256 216 15 12

50(65)

32(40)

7511.0 132S 80 132 180 316 180 140 256 216 15 12 9415.0 160M 80 160 180 316 256 210 300 254 18 15 107

40-1607.5 132S 80 132 160 264 180 140 256 216 15 12

65(80)

40(50)

7011.0 132S 80 132 160 264 180 140 256 216 15 12 89

40-200

7.5 132S 100 132 180 316 180 140 256 216 15 12 7611.0 132S 100 132 180 316 180 140 256 216 15 12 9515.0 160M 100 160 180 316 256 210 300 254 18 15 10818.5 160L 100 160 180 316 300 254 300 254 18 15 125

50-125 7.5 132S 100 132 160 264 180 140 256 216 15 12

50(65)

74

50-160

7.5 132S 100 132 180 288 180 140 256 216 15 12 7211.0 132S 100 132 180 288 180 140 256 216 15 12 9115.0 160M 100 160 180 288 256 210 300 254 18 15 10418.5 160L 100 160 180 288 300 254 300 254 18 15 121

50-200

11.0 132S 100 132 200 316 180 140 256 216 15 12 9815.0 160M 100 160 200 316 256 210 300 254 18 15 11118.5 160L 100 160 200 316 300 254 300 254 18 15 12822.0 160L 100 160 200 316 300 254 300 254 18 15 149

65-125 7.5 132S 100 132 180 288 180 140 256 216 15 12

80(100)

65(80)

77

65-160

7.5 132S 100 132 200 308 180 140 256 216 15 12 7711.0 132S 100 132 200 308 180 140 256 216 15 12 9615.0 160M 100 160 200 308 256 210 300 254 18 15 10918.5 160L 100 160 200 308 300 254 300 254 18 15 12622.0 160L 100 160 200 308 300 254 300 254 18 15 147

65-200

11.0 132S 100 132 225 348 180 140 256 216 15 12 10315.0 160M 100 160 225 348 256 210 300 254 18 15 11618.5 160L 100 160 225 348 300 254 300 254 18 15 13322.0 160L 100 160 225 348 300 254 300 254 18 15 154

Dimensions depend on housing size (DNs, DNd, a1, h2). See table of connections, page 44.

(1) Motor dimensions depend on make; motor dimensions show maximum size.(2) Flange dimensions are according to DIN EN 1092-1 (DIN 2632). Nominal diameter in parenthesis are available on request.(4) Largest diameter of pump without motor.

135

Page 136: GRUNDFOS DATA BOOKLET - Unopomp7 Euro-HYGIA® Sanitary pumps Materials Design variations See page 27. Mechanical shaft seal Grundfos offers these seal arrangements: • single seal

136

Sanitary pumpsFurther product documentation

WebCAPSWebCAPS is a Web-based Computer Aided Product Selection program available on www.grundfos.com.

WebCAPS contains detailed information on more than 185,000 Grundfos products in more than 22 languages.

In WebCAPS, all information is divided into 6 sections:

• Catalogue• Literature• Service• Sizing• Replacement• CAD drawings.

Catalogue

This section is based on fields of application and pump types, and contains • technical data• curves (QH, Eta, P1, P2, etc) which can be adapted to the den-

sity and viscosity of the pumped liquid and show the number of pumps in operation

• product photos• dimensional drawings• wiring diagrams• quotation texts, etc.

Literature

In this section you can access all the latest documents of a given pump, such as• data booklets• installation and operating instructions• service documentation, such as Service kit catalogue and

Service kit instructions• quick guides• product brochures, etc.

Service

This section contains an easy-to-use interactive service catalogue. Here you can find and identify service parts of both existing and dis-continued Grundfos pumps.Furthermore, this section contains service videos showing you how to replace service parts.

Page 137: GRUNDFOS DATA BOOKLET - Unopomp7 Euro-HYGIA® Sanitary pumps Materials Design variations See page 27. Mechanical shaft seal Grundfos offers these seal arrangements: • single seal

Further product documentation

Sanitary pumps

Sizing

This section is based on different fields of application and installa-tion examples, and gives easy step-by-step instructions in how to• select the most suitable and efficient pump for your installation• carry out advanced calculations based on energy consumption,

payback periods, load profiles, life cycle costs, etc.• analyse your selected pump via the built-in life cycle cost tool• determine the flow velocity in wastewater applications, etc.

Replacement

In this section you find a guide to selecting and comparing replace-ment data of an installed pump in order to replace the pump with a more efficient Grundfos pump. The section contains replacement data of a wide range of pumps produced by other manufacturers than Grundfos.

Based on an easy step-by-step guide, you can compare Grundfos pumps with the one you have installed on your site. When you have specified the installed pump, the guide will suggest a number of Grundfos pumps which can improve both comfort and efficiency.

CAD drawings

In this section it is possible to download 2-dimensional (2D) and 3-dimensional (3D) CAD drawings of most Grundfos pumps.

These formats are available in WebCAPS:

2-dimensional drawings:• .dxf, wireframe drawings• .dwg, wireframe drawings.

3-dimensional drawings:• .dwg, wireframe drawings (without surfaces)• .stp, solid drawings (with surfaces)• .eprt, E-drawings.

0 1

137

Page 138: GRUNDFOS DATA BOOKLET - Unopomp7 Euro-HYGIA® Sanitary pumps Materials Design variations See page 27. Mechanical shaft seal Grundfos offers these seal arrangements: • single seal

138

Page 139: GRUNDFOS DATA BOOKLET - Unopomp7 Euro-HYGIA® Sanitary pumps Materials Design variations See page 27. Mechanical shaft seal Grundfos offers these seal arrangements: • single seal

139

Page 140: GRUNDFOS DATA BOOKLET - Unopomp7 Euro-HYGIA® Sanitary pumps Materials Design variations See page 27. Mechanical shaft seal Grundfos offers these seal arrangements: • single seal

www.grundfos.com

96565334 0706 GBRepl. 96565334 0406 Subject to alterations.

Being responsible is our foundationThinking ahead makes it possible

Innovation is the essence

GRUNDFOS A/S . DK-8850 Bjerringbro . DenmarkTelephone: +45 87 50 14 00