10
General Specifications GS 01U10B00-02EN-R GS 01U10B00-02EN-R, 1st edition, 2018-10-24 Features Interoperability: PROFIBUS specifications grant the interoperability of the field instruments without preparing designated softwares for the instrument. Reduction of instrumentation cost: The multi- drop wiring on the PROFIBUS communication line contributes to the reduction of wiring cost. Function blocks: AI function blocks, Totalizer function blocks and AO function block are avail- able. (PROFIBUS PA Profile 3.02 Compliant) Supported tools: DTM for FieldMate R3.04 or later, EDDL for SIEMENS SIMATIC PDM V9.0 or V9.1. PROFIBUS in general PROFIBUS is a vendor-independent and open fieldbus based on the international standard IEC61158 and IEC61784. It covers a wide range of applications in manufacturing and process auto- mation fields. Vendor-independence and open- ness allow communication between devices of dif- ferent manufactures with no special interface ad- justment. Thus, based on PROFIBUS PA specifi- cations, ROTAMASS Total Insight PROFIBUS PA models offer more flexible instrumentation through a higher level communication capability and pro- pose the cost reduction by multi-drop wirings with less cables. Coriolis Mass Flow and Density Meter Addendum to General Specifications for PROFIBUS PA ROTA MASS Total Insight

GS 01U10B00-02EN-R, 1st edition, 2018-10-24 · Totalizer block (TOT):TOT1: Mass 1) TOT2: Volume TOT3: Corrected volume flow Analog output block (AO):AO: Pressure 1) Profile Revision

  • Upload
    others

  • View
    1

  • Download
    0

Embed Size (px)

Citation preview

Page 1: GS 01U10B00-02EN-R, 1st edition, 2018-10-24 · Totalizer block (TOT):TOT1: Mass 1) TOT2: Volume TOT3: Corrected volume flow Analog output block (AO):AO: Pressure 1) Profile Revision

GeneralSpecifications

GS 01U10B00-02EN-R

GS 01U10B00-02EN-R, 1st edition, 2018-10-24

Features

▪ Interoperability: PROFIBUS specifications grantthe interoperability of the field instruments withoutpreparing designated softwares for the instrument.

▪ Reduction of instrumentation cost: The multi-drop wiring on the PROFIBUS communication linecontributes to the reduction of wiring cost.

▪ Function blocks: AI function blocks, Totalizerfunction blocks and AO function block are avail-able. (PROFIBUS PA Profile 3.02 Compliant)

▪ Supported tools: DTM for FieldMate R3.04 or later, EDDL for SIEMENS SIMATIC PDM V9.0 or V9.1.

PROFIBUS in general

▪ PROFIBUS is a vendor-independent and openfieldbus based on the international standardIEC61158 and IEC61784. It covers a wide rangeof applications in manufacturing and process auto-mation fields. Vendor-independence and open-ness allow communication between devices of dif-ferent manufactures with no special interface ad-justment. Thus, based on PROFIBUS PA specifi-cations, ROTAMASS Total Insight PROFIBUS PAmodels offer more flexible instrumentation througha higher level communication capability and pro-pose the cost reduction by multi-drop wirings withless cables.

Coriolis Mass Flow and Density MeterAddendum to General Specificationsfor PROFIBUS PA

ROTAMASS  Total Insight

Page 2: GS 01U10B00-02EN-R, 1st edition, 2018-10-24 · Totalizer block (TOT):TOT1: Mass 1) TOT2: Volume TOT3: Corrected volume flow Analog output block (AO):AO: Pressure 1) Profile Revision

Table of contents

2 / 10 GS 01U10B00-02EN-R, 1st edition, 2018-10-24

Table of contents1 Introduction................................................................................................................................................ 3

1.1 General information .......................................................................................................................... 3

2 PROFIBUS PA Specifications................................................................................................................... 42.1 Inputs and outputs ............................................................................................................................ 5

2.1.1 PROFIBUS PA Output signals............................................................................................. 5

3 Advanced functions and Features on Demand (FOD) ........................................................................... 7

4 Ordering information................................................................................................................................. 84.1 Model code ....................................................................................................................................... 8

4.1.1 Transmitter ........................................................................................................................... 84.1.2 Communication type and I/O ............................................................................................... 8

4.2 Overview model codes PROFIBUS PA restrictions.......................................................................... 84.3 Overview options PROFIBUS PA restrictions................................................................................... 94.4 Ordering Instructions ........................................................................................................................ 9

Page 3: GS 01U10B00-02EN-R, 1st edition, 2018-10-24 · Totalizer block (TOT):TOT1: Mass 1) TOT2: Volume TOT3: Corrected volume flow Analog output block (AO):AO: Pressure 1) Profile Revision

General information

Addendum to General Specifications for PROFIBUS PAIntroduction

GS 01U10B00-02EN-R, 1st edition, 2018-10-24 3 / 10

1 Introduction

1.1 General information

This document is an addendum to the General Specifications GS 01U10B0␣ -00␣␣-R. Itdescribes the differences of the delivered product compared to the applicable “GeneralSpecifications” that specifies standard devices of ROTAMASS Total Insight series. Thedeviations could be model code related, design or configuration only and are listed on thenext pages.

Page 4: GS 01U10B00-02EN-R, 1st edition, 2018-10-24 · Totalizer block (TOT):TOT1: Mass 1) TOT2: Volume TOT3: Corrected volume flow Analog output block (AO):AO: Pressure 1) Profile Revision

Addendum to General Specifications for PROFIBUS PAPROFIBUS PA Specifications

4 / 10 GS 01U10B00-02EN-R, 1st edition, 2018-10-24

2 PROFIBUS PA Specifications

Overviewof functional scopeof the RotamassPROFIBUS PAspecifications

Functional scope Values, ranges and specifications availableModel code(position 13)

G0 (PROFIBUS PA) ●G1 (PROFIBUS PA Intrinsic Safe) ●

Output signal:Digital communication signal based on PROFIBUS PA protocol (Profile Revision R3.02 Compliant)PROFIBUS PA block specifications:

▪ Transducer block (TB):Flow Transducer Block (FTB) ●Concentration Transducer Block (CTB) optionalLCD Indicator Transducer Block (LTB) ●Maintenance Transducer Block (MTB) ●Advanced Diagnostic Transducer Block (ADTB) optional

▪ Analog Input block (AI):1)

AI1: Mass flow ●AI2: Density ●AI3: Temperature ●AI4: Volume flow ●AI5: Reference density ●AI6: Corrected volume flow ●

▪ Totalizer block (TOT):1)

TOT1: Mass ●TOT2: Volume ●TOT3: Corrected volume flow ●

▪ Analog output block (AO):1)

AO: Pressure ●▪ Profile Revision R3.02:

Condensed Status (NE 107) ●Life Cycle Management (Automatic IDENT_NUMBERadaptation) ●

▪ DP-V0 cyclic data:AI x 6, TOT x 3, AO x 1 ●

▪ IDENT number:0x45A0 (manufacturer specific) ●0x9740, 0x9741, 0x9742 (profile specific) ●

▪ GSD:YEC45A0.gsd, pa139740.gsd, pa139741.gsd,pa139742.gsd ●

Conditions of Communication Line:Supply voltagefrom the Bus: 9 to 32 VDC ●

Current draw: 15mA (maximum) ●

Page 5: GS 01U10B00-02EN-R, 1st edition, 2018-10-24 · Totalizer block (TOT):TOT1: Mass 1) TOT2: Volume TOT3: Corrected volume flow Analog output block (AO):AO: Pressure 1) Profile Revision

Inputs and outputs

Addendum to General Specifications for PROFIBUS PAPROFIBUS PA Specifications

GS 01U10B00-02EN-R, 1st edition, 2018-10-24 5 / 10

Functional scope Values, ranges and specifications availableBus address switch:via Hardware address switch or via SoftwareAlarm selection function:These informations are indicated in DIAGNOSTICS parameter, which can be handledduring normal operation.Displayed language:In the case of PROFIBUS PA communication type, different language packages are possible to choose.

1) Factory default setting; can be changed by parameter "Channel".

meaning of "−": not available; meaning of "●": available

2.1 Inputs and outputs

For the PROFIBUS PA version there is only one configuration of the connection terminal.Following is the configuration of the connection terminal (value G0 and G1 on model codeposition 13):

WP

ON/

OFF

Fieldbus Pulse

(I/O1) (I/O2)

PROFIBUS PA I/O1: Fieldbus PROFIBUS PA communicationI/O2: Pulse Pulse / Frequency outputWP: Write-protect bridge

2.1.1 PROFIBUS PA Output signalsDigital communication signal based on PROFIBUS PA protocol.

Maximum voltage and correct polarity must be observed for wiring.PROFIBUS PA Value

Power supply 9 to 32 VDC

Current draw 15mA (maximum)

ROTAMASSFieldbus+

Fieldbus-

4

3

1

5

22

Fig. 1: PROFIBUS PA connection

① PROFIBUS PA② Terminator③ DP/PA-Coupler④ PROFIBUS DP⑤ Host

Page 6: GS 01U10B00-02EN-R, 1st edition, 2018-10-24 · Totalizer block (TOT):TOT1: Mass 1) TOT2: Volume TOT3: Corrected volume flow Analog output block (AO):AO: Pressure 1) Profile Revision

Addendum to General Specifications for PROFIBUS PAPROFIBUS PA Specifications Inputs and outputs

6 / 10 GS 01U10B00-02EN-R, 1st edition, 2018-10-24

Passive pulseoutput (only forcalibration)

ValueMaximum load current ≤ 200 mAPower supply ≤ 30 VDC

Maximum pulse rate 10000 pulses/sFrequency range 0 – 12.5 kHz

ROTAMASS

Pulse+

Pulse-

321

Fig. 2: Passive pulse output connection with electronic counter

① Passive pulse② Load resistance③ Electronic counter

ROTAMASS

Pulse+

Pulse-

321

Fig. 3: Passive pulse output connection with electromechanical counter

① Passive pulse② Protective diode③ Electromechanical counter

Page 7: GS 01U10B00-02EN-R, 1st edition, 2018-10-24 · Totalizer block (TOT):TOT1: Mass 1) TOT2: Volume TOT3: Corrected volume flow Analog output block (AO):AO: Pressure 1) Profile Revision

Addendum to General Specifications for PROFIBUS PAAdvanced functions and Features on Demand (FOD)

GS 01U10B00-02EN-R, 1st edition, 2018-10-24 7 / 10

3 Advanced functions and Features on Demand (FOD)

ROTAMASS Total Insight includes many dedicated application and maintenance func-tions that can be ordered simultaneously with the device or can be purchased and acti-vated in a second time (only with the Ultimate transmitter).

Advancedfunctions

Transmitter Communication type and I/OFunctional scope Ultimate Available type

YOKOGAWA

Ultimate

YOKOGAWA

Ultimate

PROFIBUSPA

Model code (pos. 1 and 13) U G␣Standard concentrationmeasurement ● ●

Advanced concentrationmeasurement ● ●

Net Oil Computing (NOC)following API standard ● ●

Tube health check ● ●Batching function ● −Viscosity function ● ●Measurement of heat quantity ● ●

meaning of "−": not available; meaning of "●": available

To order these functions refer to the related general specifications for FOD functions(GS01U10B20-00␣␣-R).

Page 8: GS 01U10B00-02EN-R, 1st edition, 2018-10-24 · Totalizer block (TOT):TOT1: Mass 1) TOT2: Volume TOT3: Corrected volume flow Analog output block (AO):AO: Pressure 1) Profile Revision

Addendum to General Specifications for PROFIBUS PAOrdering information Model code

8 / 10 GS 01U10B00-02EN-R, 1st edition, 2018-10-24

4 Ordering information

4.1 Model code

4.1.1 Transmitter

- - - - /-RC

1 2 3 4 6 75 9 10 11 12 13 14 158

Model codeposition 1

Transmitter

U1) Ultimate1) PROFIBUS PA communication protocol is supported by Ultimate transmitter only and isnot available with Essential transmitter.

4.1.2 Communication type and I/O

- - - - /-RC

1 2 3 4 6 75 9 10 11 12 13 14 158

PROFIBUS PA Model codeposition 13

Connection terminal assignmentI/O1 +/- I/O2 +/- I/O3 +/- I/O4 +/- WP

G0 PROFIBUSPA

PulsePassive

– – Write-protect

G1 PROFIBUSPA (IS)

PulsePassive (IS)

– – Write-protect

PROFIBUS PA PA communicationPulse Passive Pulse / Frequency output

Intrinsically safe (IS) outputs are only available in combination with selecting Ex approvalof the device, see chapter Ex approval.

4.2 Overview model codes PROFIBUS PA restrictions

- - - - /-RC

1 2 3 4 6 75 9 10 11 12 13 14 158

Model code

position

1. 2. 3. 4. 5. 6. 7. 8. 9. 10. 11. 12. 13. 14. Description Restriction

Transmitter E Essential (basic function) not with communication type and I/O G␣

Ex approval

FF11 FM, groups A, B, C, D, E, F, Gnot with communication type and I/O G␣

FF12 FM, groups C, D, E, F, G

NF21 NEPSI, explosion group IIC and IIICnot with communication type and I/O G␣

NF22 NEPSI, explosion group IIB and IIIC

Page 9: GS 01U10B00-02EN-R, 1st edition, 2018-10-24 · Totalizer block (TOT):TOT1: Mass 1) TOT2: Volume TOT3: Corrected volume flow Analog output block (AO):AO: Pressure 1) Profile Revision

Overview options PROFIBUS PArestrictions

Addendum to General Specifications for PROFIBUS PAOrdering information

GS 01U10B00-02EN-R, 1st edition, 2018-10-24 9 / 10

4.3 Overview options PROFIBUS PA restrictions

Option category

Options Description Restriction

Presetting of customer para-meters

PS Presetting according to customer parameters not with communication typeand I/O G␣

Country-specific application Q11 PESO approval delivery not with communication type

and I/O G1

Marine ApprovalMC2 Marine approval according to DNV GL piping class 2 not with communication type

and I/O G␣MC3 Marine approval according to DNV GL piping class 3

Batching function BT Batching and filling function not with communication typeand I/O G␣

4.4 Ordering Instructions

In addition to the ordering information described in GS 01U10B0˽ -00˽ ˽-R, forPROFIBUS PA communication type please specify the following information when ordering a product:

Ordering information Parameter ValueNODE ADDRESS (HEX): up to 4 characters length Default value '0x7E' unless otherwise specified

SOFTWARE TAG: up to 32 characters length Default value 'FT2001' unless otherwise specified

Page 10: GS 01U10B00-02EN-R, 1st edition, 2018-10-24 · Totalizer block (TOT):TOT1: Mass 1) TOT2: Volume TOT3: Corrected volume flow Analog output block (AO):AO: Pressure 1) Profile Revision

YOKOGAWA ELECTRIC CORPORATION

YOKOGAWA CORPORATION OF AMERICA

YOKOGAWA AMERICA DO SUL LTDA.

YOKOGAWA EUROPE B. V.

Euroweg 2, 3825 HD Amersfoort,

THE NETHERLANDS

Phone : 31-88-4641000

Fax : 31-88-4641111

YOKOGAWA INDIA LTD.

Plot No.96, Electronic City Complex,

Hosur Road, Bangalore - 560 100,

INDIA

Phone : 91-80-4158-6000

Fax : 91-80-2852-1442

YOKOGAWA AUSTRALIA PTY. LTD.

Tower A, 112-118 Talavera Road,

Macquarie Park NSW 2113,

AUSTRALIA

Phone : 61-2-8870-1100

Fax : 61-2-8870-1111

YOKOGAWA MIDDLE EAST & AFRICA B.S.C.(C)

P.O. Box 10070, Manama, Building 577,

Road 2516, Busaiteen 225, Muharraq,

Kingdom of BAHRAIN

Phone : 973-17358100

Fax : 973-17336100

Headquarters

2-9-32, Nakacho, Musashino-shi,

Tokyo, 180-8750 JAPAN

Phone : 81-422-52-5555

Branch Sales Offices

Osaka, Nagoya, Hiroshima,

Kurashiki, Fukuoka, Kitakyusyu

Head Office

12530 West Airport Blvd, Sugar Land,

Texas 77478, USA

Phone : 1-281-340-3800

Fax : 1-281-340-3838

Georgia Office

2 Dart Road, Newnan, Georgia 30265, USA

Phone : 1-800-888-6400/ 1-770-253-7000

Fax : 1-770-254-0928

Praca Acapulco, 31 - Santo Amaro, Sáo Paulo/SP,

BRAZIL, CEP-04675-190

Phone : 55-11-5681-2400

Fax : 55-11-5681-4434

YOKOGAWA ELECTRIC CIS LTD.

Grokholskiy per 13 Building 2, 4th Floor 129090,

Moscow, RUSSIA

Phone : 7-495-737-7868

Fax : 7-495-737-7869

YOKOGAWA CHINA CO., LTD.

3F Tower D Cartelo Crocodile Building,

No.568 West Tianshan Road,

Shanghai 200335, CHINA

Phone : 86-21-62396262

Fax : 86-21-62387866Z

YOKOGAWA ELECTRIC KOREA CO., LTD.

(Yokogawa B/D, Yangpyeong-dong 4-Ga),21, Seonyu-ro 45-gil, Yeongdeungpo-gu,Seoul, 150-866, KOREA

Phone : 82-2-2628-6000

Fax : 82-2-2628-6400

YOKOGAWA ENGINEERING ASIA PTE. LTD.

5 Bedok South Road, Singapore 469270,

SINGAPORE

Phone : 65-6241-9933

Fax : 65-6241-2606 ISO 9001

GS 01U10B00-02EN-R, 1st edition, 2018-10-24

All rights reserved. Copyright © 2018-10-24