DOCUMENT STORAGE STORE T1 STRONG ROOM GENTS LADIES GENTS GENTS NEW LADIES NEW KITCHEN NEW D1 LADIES LADIES G16-2 G16-3 G16-4 New Storeroom NEW LIFT TRAINING ROOM B TRAINING ROOM A EXISTING PRODUCT DEVELOPMENT / TESTING AREA STORE ROOM NEW PAUSE AREA NEW LOBBY 17m2 FILING ROOM DB BUILT IN MACHINE ROOM DB 28m2 28m2 11m2 11m2 G01G G01H G01E G01F G01D STORE G07 G08 G06 G12 G09 G10 G11 G13 G17 G18 G19 G01i G04 D/A LOBBY GENTS LADIES G25 G26 G24 G23 G21 NEW STAFF STORE ROOM D2 WORKSHOP / MOCK UP AREA Remove ex. wallpaper & prep wall for paint EXECUTIVE 2 GMD OFFICE EXECUTIVE 3 STRATEGIC 1 STRATEGIC 2 EXECUTIVE PA STORE G05 BUILT IN MACHINE ROOM G17 G16 EXECUTIVE BOARDROOM A TEA KITCHEN RECEPTION WALL LIGHT FEATURE (x15) 6000 6000 6000 6000 6000 6000 6000 6000 6000 6000 6000 6000 6000 6000 6000 6000 6000 6000 6000 6000 6000 600d bulkhead 300h 2400affl 600d bulkhead 300h 2400affl GF SOUTH WING GF NORTH WING VISITORS LOUNGE EXECUTIVE 1 GMD PA New smooth plastered ceiling over visitors lounge 50m2 3000h Ex. suspended ceiling 600x1200 ex skimmed ceiling Ex. suspended ceiling 600x1200 Ex. suspended ceiling 600x1200 Ex. suspended ceiling 600x1200 Ex. suspended ceiling 600x1200 ex skimmed ceiling ex skimmed ceiling 600d bulkhead 300h 2400affl 600d bulkhead 300h 2400affl WALL LIGHT FEATURE (x8) Suspended ceiling 2100mm H 2700mm H 2700mm H 2400mm H 3000mm H 2700mm H 2700mm H 2700mm H 2700mm H 2700mm H 2700mm H 2700mm H 2700mm H 2700mm H 3000mm H 3000mm H 3000mm H 3000mm H 3000mm H 3000mm H 3000mm H 2700mm H 2700mm H 2700mm H 2700mm H 2700mm H 2100mm H 2700mm H 2700mm H 2700mm H 2700mm H Ex. suspended ceiling 2400mm H 2400mm H 2400mm H 2400mm H 2400mm H 2400mm H 2700mm H 2700mm H No Ceiling No ceiling 2700mm H 2700mm H 2700mm H 2700mm H D1 Suspended ceiling ex. skimmed ceiling New New ceiling tiles New ceiling tiles SG01 AC 01 FB1 RG04 568l/s 50mm DRAIN POINT TO BE CHASED INTO WALL BY PLUMBER BD FB1 RG04 568l/s BD AC-01 AC-02 3.2 FLA 220/50/1 POWER SUPPLY MOUNTED ADJACENT TO OUTDOOR UNIT BY SITE ELECTRICIAN (2 - OFF) WL01 67l/s 250x200 AC 02 50mm DRAIN POINT TO BE CHASED INTO WALL BY PLUMBER WL02 67l/s 250x200 WL02 450l/s 600x550 472L SA1 FT1 472L SA1 DV01 50l/s DV01 50l/s DV01 50l/s DV01 50l/s DV01 50l/s DV01 50l/s DV01 50l/s DV01 50l/s DV01 50l/s SE FB1 45° SE LD02 75l/s LD02 75l/s D02 75l/s LD02 75l/s D02 75l/s LD02 75l/s LD02 75l/s CV01 75l/s FB2 472L SA2 FT2 472L SA2 AC 04 FB1 BD BD SE LD02 75l/s LD02 75l/s LD02 75l/s D02 75l/s D02 75l/s CV01 75l/s LD02 75l/s LD02 75l/s CV01 75l/s SE D02 75l/s 45° RG04 241l/s RG04 241l/s CV01 75l/s LD02 75l/s LD02 75l/s LD02 75l/s LD02 75l/s CV01 75l/s RG04 241l/s RG04 241l/s AC-03 AC-04 AC-06 FB1 AC 06 47 000BTU SE 0.26kW 220/50/1 POWER SUPPLY ON 7-DAY TIMER MOUNTED ADJACENT TO FAN BY SITE ELECTRICIAN 3.2 FLA 220V/50/1 POWER SUPPLY MOUNTED ADJACENT TO OUTDOOR BY SITE ELECTRICIAN (2-OFF) 7.33kW 380/50/1 POWER SUPP:LY MOUNTED ADJACENT TO OUTDOOR UNIT BY SITE ELECTRICIAN (2-OFF) 0.58 kW 220/50/1 POWER SUPPLY ON 7-DAY TIMER MOUNTED ADJACENT TO FAN BY SITE ELECTRICIAN AC07 AC14 AC11 AC09 AC13 AC12 AC10 SG01 SG01 SG01 SG01 SG01 SG01 SE SG01 BD1 BD1 BD1 BD1 BD1 BD1 BD1 BD1 CV02 220l/s CV02 220l/s SE RG04 300l/s BD WL04 800l/s 950x800 AC 05 SG04 75l/s SG04 75l/s SG04 75l/s SG04 75l/s SG04 75l/s SG04 75l/s SG04 75l/s 45° SE SE SE SG01 SG01 SG01 300L SA3 300L SA4 WMS FT3 0.26 kW 220/50/1 POWER SUPPLY ON 7-DAY TIMER MOUNTED ADJACENT TO FAN BY SITE ELECTRICIAN 50mm DRAIN POINT TO BE CHASED INTO WALL BY PLUMBER ∅300 ∅200 ∅200 ∅250 ∅200 ∅200 ∅200 ∅200 ∅200 ∅200 ∅200 MID ∅350 ∅200 ∅200 ∅250 RG06 400l/s FOB ∅400 FOT ∅450 ∅350 ∅300 ∅300 CV02 220l/s ∅200 ∅200 ∅250 ∅300 ∅200 FOB ∅300 ∅450 ∅350 ∅200 FOB ∅200 ∅250 ∅200 ∅200 ∅200 ∅200 ∅200 ∅200 ∅300 ∅350 ∅200 ∅200 300L FOT ∅300 MID MID AC 03 AC 10 AC 11 AC 12 AC 08 AC 09 AC 07 AC 14 AC 13 ∅200 AC08 AC 05 50mm DRAIN POINT TO BE CHASED INTO WALL BY PLUMBER RG07 400l/s ∅350 MID AC 15 CV03 140l/s CV03 140l/s CV03 140l/s SE AC 15 ∅300 45° ∅200 1090L 3975L ∅350 3465L SE ∅200 670L ∅200 650L ∅200 365L ∅200 1100L ∅200 1225L CV04 175l/s CV04 175l/s CV04 175l/s CV04 175l/s CV04 175l/s CV04 175l/s CV04 175l/s CV04 175l/s SE SE 45° ∅250 800L 45° ∅250 800L ∅250 ∅250 450x300 FOT 45° FOT 450x300 ∅250 ∅250 45° ∅200 3075L 45° ∅200 1350L 45° ∅200 1490L ∅200 3680L AC 16 AC 16 FC1 BOX GUTTER TO ENG'S SPEC. & DETAIL 40 AC DRAIN TO RECEIVE INDIVIDUAL P-TRAPS CEILING VOID 45° PVC ELBOW 40Ø PVC PIPE BUILT INTO WALL STUB STACK 110Ø PVC DPC 40Ø PVC CL 34 40Ø PVC PIPE ABOVE CEILING - CHASED INTO WALL BY PLUMBER 45° DETAIL 1 : TYPICAL DETAIL OF Ø50 CONDENSATE DRAIN POINT N.T.S Split Unit Schedule Code Type Btu Quantity AC 07 Ceiling Cassette AC Unit 18000 1 AC 09 Ceiling Cassette AC Unit 18000 1 AC 11 Ceiling Cassette AC Unit 9000 1 AC 12 Ceiling Cassette AC Unit 9000 1 AC 13 Ceiling Cassette AC Unit 18000 1 AC 14 Ceiling Cassette AC Unit 18000 1 AC 08 Ceiling Cassette AC Unit 24000 1 AC 10 Ceiling Cassette AC Unit 24000 1 AC 05 Ceiling Concealed AC Unit 24000 1 AC 01 Ceiling Concealed AC Unit 36000 1 AC 02 Ceiling Concealed AC Unit 36000 1 AC 03 Ceiling Concealed AC Unit 36000 1 AC 04 Ceiling Concealed AC Unit 36000 1 AC 06 Ceiling Concealed AC Unit 36000 1 AC 15 AC 16 Ceiling Concealed AC Unit 24000 1 Ceiling Cassette AC Unit 24000 1 Terminal Schedule Code Type Size Heater Spigots ∅ Quantity CV01 CAV Round ∅600 - 200 5 CV02 CAV Round ∅600 - 300 3 CV03 CAV Round ∅600 - 250 3 CV04 CAV 4wb 600x600 - 250 8 DV01 EA Valve ∅200 - 200 9 RG04 Return Air Fixed Blade 1200x600 - 350x2 3 RG05 Return Air Fixed Blade 600x600 - 350 4 RG06 Return Air Fixed Blade 1200x600 - 300x2 1 RG07 Return Air Fixed Blade 1200x600 - 200x2 1 SG02 Supply Air Fixed Blade 550x250 - - 14 SG03 Supply Air Fixed Blade 600x600 - - 11 SG04 Supply Air Fixed Blade 300x150 - 100 7 WL02 FA Louvre 250x200 - - 2 WL03 EA Louvre 600x550 - - 1 WL04 FA Louvre 950x800 - - 1 Damper Schedule Code Type Size Quantity DA 1 Balancing Damper ∅200 8 Filter Bank Schedule Code Type Size Quantity FB 1 Filter Bank 1400x282 5 FB 2 Filter Bank 950x800 1 Fan Schedule Code Type Size Quantity FT 1 In-line Tube Fan ∅315 1 FT 2 In-line Tube Fan ∅400 1 FT 3 In-line Tube Fan ∅200 1 Sound Attenuator Schedule Code Type Size Quantity SA 1 472 Long Circular SA No Pod ∅315 2 SA 2 472 Long Circular SA No Pod ∅400 2 SA 3 300 Long Circular SA No Pod ∅200 1 SA 4 300 Long Circular SA No Pod ∅200 1 FC 1 Ceiling Mounted Fan ∅250 1 Checked Designed Scale Drawing A110 - Rev 1 1:100 (A0) 2019-03-01 Date Drawn D.F. Dwg.Description Air-Conditioning and Ventilation REV. NO: Installation Project DESCRIPTION: DATE: 1 Issue for Tender Purposes 2019-03-01 Building C4 Renovations: New NTP Offices Air-Conditioning and Ventilation Specifications & Layout H.A. Project Managers : Client : Y.J.

H I J K L M N O A B C D E F G P - Necsa · ∅350 ∅300 ∅300 cv02220l/s ∅200 ∅250∅200 ∅300 ∅200 fob ∅300 ∅450 ∅350∅200 fob ∅200 ∅250 ∅200∅200∅200∅200∅200∅200

  • Upload
    others

  • View
    6

  • Download
    0

Embed Size (px)

Citation preview

Page 1: H I J K L M N O A B C D E F G P - Necsa · ∅350 ∅300 ∅300 cv02220l/s ∅200 ∅250∅200 ∅300 ∅200 fob ∅300 ∅450 ∅350∅200 fob ∅200 ∅250 ∅200∅200∅200∅200∅200∅200

DOCUMENT STORAGE

UP

UP

UP

UP

STORE

T1

G09

STRONG

ROOM

GENTS

LADIES

GENTS

GENTS NEW LADIES

NEW KITCHEN

NEW

D1

LADIESLADIES

G16-2G16-3G16-4

New Storeroom

NEW

LIFT

TRAINING ROOM B

TRAINING ROOM A

EXISTING

PRODUCT DEVELOPMENT / TESTING AREA

STORE ROOM

NEW PAUSE AREA

NEW

LOBBY

17m2

FILING ROOM

DB

BUILT IN

MACHINE

ROOM

DB

28m2

28m2

11m2

11m2

G01G

G01H

G01E

G01F

G01D

STORE

G07

G08

G06

G12

G09

G10

G11

G13

G17

G18

G19

G01i

G04

D/A

LOBBY

GE

NT

S

LADIES

G25

G26

G24

G23

G21

NEW STAFF STORE ROOM

D2

WORKSHOP / MOCK UP AREA

Remove ex. wallpaper

& prep wall for paint

EXECUTIVE 2

GMD OFFICE

EXECUTIVE 3

STRATEGIC 1

STRATEGIC 2

EXECUTIVE PA

STORE

G05

BUILT IN

MACHINE

ROOM

G17

G16

EXECUTIVE BOARDROOM A

TEA

KITCHEN

RECEPTION

WALL LIGHT FEATURE (x15)

A B C D E F G P

O

1

2

3

4

5

6

H I J K L M N O

60006000600060006000600060006000600060006000600060006000 6000

60

00

60

00

60

00

60

00

60

00

60

00

600d bulkhead 300h

2400affl

600d bulkhead 300h

2400affl

GF SOUTH WING

GF NORTH WING

VISITORS LOUNGE

EXECUTIVE 1

GMD PA

New smooth plastered ceiling

over visitors lounge 50m2

3000h

Ex. suspended ceiling

600x1200

ex skimmed

ceiling

Ex. suspended ceiling

600x1200

Ex. suspended ceiling

600x1200

Ex. suspended ceiling

600x1200

Ex. suspended ceiling

600x1200

ex skimmedceiling

ex skimmed

ceiling

600d bulkhead 300h

2400affl

600d bulkhead 300h

2400affl

WA

LL

L

IG

HT

FE

AT

UR

E (x8

)

Suspended ceiling 2100mm H

2700mm H

2700mm H

2400mm H

3000mm H

2700mm H

2700mm H

2700mm H

2700mm H

2700mm H

2700mm H

2700mm H

2700mm H

2700mm H

3000mm H

3000mm H

3000mm H

3000mm H

3000mm H

3000mm H

3000mm H

2700mm H

2700mm H

2700mm H

2700mm H

2700mm H

2100mm H

2700mm H

2700mm H

2700mm H

2700mm H

Ex. suspended ceiling

2400mm H

2400mm H

2400mm H

2400mm H

2400mm H

2400mm H

2700mm H

2700mm H

No Ceiling

No ceiling

2700mm H

2700mm H

2700mm H

2700mm H

D1

Suspended ceiling

ex. skimmed ceiling

New

New ceiling tiles

New ceiling tiles

SG01

AC 01

FB1

RG04

568l/s

∅50mm DRAIN POINT

TO BE CHASED INTO

WALL BY PLUMBER

BD

FB1

RG04

568l/s

BD

AC-01

AC-02

3.2 FLA 220/50/1POWER SUPPLYMOUNTED ADJACENTTO OUTDOOR UNIT BYSITE ELECTRICIAN(2 - OFF)

WL01

67l/s

250x200

AC 02

∅50mm DRAIN POINT

TO BE CHASED INTO

WALL BY PLUMBER

WL02

67l/s

250x200

WL02

450l/s

600x550

472L

SA1

FT1

472L

SA1

DV01

50l/s

DV01

50l/s

DV01

50l/s

DV01

50l/s

DV01

50l/s

DV01

50l/s

DV01

50l/s

DV01

50l/s

DV01

50l/s

SE

FB1

45°

SE

LD02

75l/s

LD02

75l/s

D02

75l/s

LD02

75l/s

D02

75l/s

LD02

75l/s

LD02

75l/s

CV01

75l/s

FB2

472L

SA2

FT2

472L

SA2

AC 04

FB1

BD

BD

SE

LD02

75l/s

LD02

75l/s

LD02

75l/s

D02

75l/s

D02

75l/s

CV01

75l/s

LD02

75l/s

LD02

75l/s

CV01

75l/s

SE

D02

75l/s

45°

RG04

241l/s

RG04

241l/s

CV01

75l/s

LD02

75l/s

LD02

75l/s

LD02

75l/s

LD02

75l/s

CV01

75l/s

RG04

241l/s

RG04

241l/s

AC-03 AC-04 AC-06

FB1

AC 06

47 000BTU

SE

0.26kW 220/50/1

POWER SUPPLY ON 7-DAY

TIMER MOUNTED ADJACENT

TO FAN BY SITE

ELECTRICIAN

3.2 FLA 220V/50/1 POWER

SUPPLY MOUNTED

ADJACENT TO OUTDOOR

BY SITE ELECTRICIAN

(2-OFF)

7.33kW 380/50/1

POWER SUPP:LY

MOUNTED ADJACENT

TO OUTDOOR UNIT BY

SITE ELECTRICIAN

(2-OFF)

0.58 kW 220/50/1

POWER SUPPLY ON 7-DAY

TIMER MOUNTED ADJACENT

TO FAN BY SITE

ELECTRICIAN

AC07

AC14

AC11

AC09

AC13

AC12

AC10

SG01

SG01

SG01

SG01

SG01

SG01

SE

SG01

BD1

BD1

BD1

BD1

BD1

BD1

BD1

BD1

CV02

220l/s

CV02

220l/s

SE

RG04

300l/s

BD

WL04

800l/s

950x800

AC 05

SG04

75l/s

SG04

75l/s

SG04

75l/s

SG04

75l/s

SG04

75l/s

SG04

75l/s

SG04

75l/s

45°

SE

SE

SE

SG01

SG01

SG01

300L

SA3

300L

SA4

WMS

FT3

0.26 kW 220/50/1

POWER SUPPLY ON 7-DAY

TIMER MOUNTED ADJACENT

TO FAN BY SITE

ELECTRICIAN

∅50mm DRAIN POINT TO BE

CHASED INTO WALL BY

PLUMBER

∅300

∅200

∅200

∅250

∅200 ∅200

∅200

∅200

∅200

∅200

∅200

MID

3

5

0

2

0

0

2

0

0

2

5

0

RG06 400l/s

FO

B

∅400

FO

T

∅450

∅350

∅300

∅300

CV02

220l/s

∅200

∅200

∅250

∅300

∅200

FO

B

3

0

0

∅450

∅350

∅200

FO

B

∅200

∅250

∅200

∅200

∅200

∅200

∅200

∅200

∅300

∅350

∅200

∅200

300L

FO

T

∅300

MID

MID

AC 03

AC 10 AC 11

AC 12

AC 08

AC 09

AC 07

AC 14

AC 13

∅200

AC08

AC 05

∅50mm DRAIN POINT TO BE

CHASED INTO WALL BY

PLUMBER

RG07

400l/s

∅350

MID

AC 15

CV03

140l/s

CV03

140l/s

CV03

140l/s

SE

AC 15

∅300

45°

2

0

0

1

0

9

0

L

3975L

3

5

0

3

4

6

5

L

SE

2

0

0

6

7

0

L

2

0

0

6

5

0

L

2

0

0

3

6

5

L

2

0

0

1

1

0

0

L

2

0

0

1

2

2

5

L

CV04

175l/s

CV04

175l/s

CV04

175l/s

CV04

175l/s

CV04

175l/s

CV04

175l/s

CV04

175l/s

CV04

175l/s

SE

SE

45°

2

5

0

8

0

0

L

45°

2

5

0

8

0

0

L

∅250

∅250

450x300

FO

T

45°

FO

T

450x300

∅250 ∅250

45°

∅200

3075L

45°

2

0

0

1

3

5

0

L

45°

∅200

1490L

∅200

3680L

AC 16

AC 16

FC1

BOX GUTTER TO ENG'SSPEC. & DETAIL

4

0

AC DRAIN TO RECEIVEINDIVIDUAL P-TRAPS

CEILING VOID

45° PVC ELBOW

40Ø PVC PIPEBUILT INTO WALL

STUB STACK

110Ø PVC

DPC

40Ø PVC CL 34

40Ø PVC PIPE ABOVECEILING - CHASED INTOWALL BY PLUMBER

4

5

°

DETAIL 1 : TYPICAL DETAIL OF Ø50CONDENSATE DRAIN POINTN.T.S

Split Unit Schedule

Code Type Btu

Quantity

AC 07 Ceiling Cassette AC Unit 18000

1

AC 09 Ceiling Cassette AC Unit 18000

1

AC 11 Ceiling Cassette AC Unit 9000

1

AC 12 Ceiling Cassette AC Unit 9000

1

AC 13 Ceiling Cassette AC Unit 18000 1

AC 14 Ceiling Cassette AC Unit 18000 1

AC 08 Ceiling Cassette AC Unit 24000

1

AC 10 Ceiling Cassette AC Unit 24000

1

AC 05 Ceiling Concealed AC Unit 24000

1

AC 01 Ceiling Concealed AC Unit 36000 1

AC 02 Ceiling Concealed AC Unit 36000 1

AC 03 Ceiling Concealed AC Unit 36000 1

AC 04 Ceiling Concealed AC Unit 36000 1

AC 06 Ceiling Concealed AC Unit 36000 1

AC 15

AC 16

Ceiling Concealed AC Unit 24000 1

Ceiling Cassette AC Unit 24000 1

Terminal Schedule

Code Type Size Heater

Spigots ∅ Quantity

CV01 CAV Round ∅600

-

200 5

CV02 CAV Round ∅600

-

300 3

CV03 CAV Round ∅600

-

250 3

CV04 CAV 4wb 600x600

-

250 8

DV01 EA Valve ∅200

-

200 9

RG04 Return Air Fixed Blade 1200x600

-

350x2 3

RG05 Return Air Fixed Blade 600x600

-

350 4

RG06 Return Air Fixed Blade 1200x600

-

300x2 1

RG07 Return Air Fixed Blade 1200x600

-

200x2 1

SG02 Supply Air Fixed Blade 550x250

- -

14

SG03 Supply Air Fixed Blade 600x600

- -

11

SG04 Supply Air Fixed Blade 300x150

-

100 7

WL02 FA Louvre 250x200

- -

2

WL03 EA Louvre 600x550

- -

1

WL04 FA Louvre 950x800

- -

1

Damper Schedule

Code Type Size

Quantity

DA 1 Balancing Damper ∅200 8

Filter Bank Schedule

Code Type Size

Quantity

FB 1 Filter Bank 1400x282 5

FB 2 Filter Bank 950x800 1

Fan Schedule

Code Type Size

Quantity

FT 1 In-line Tube Fan ∅315 1

FT 2 In-line Tube Fan ∅400 1

FT 3 In-line Tube Fan ∅200 1

Sound Attenuator Schedule

Code Type Size

Quantity

SA 1 472 Long Circular SA No Pod ∅315 2

SA 2 472 Long Circular SA No Pod ∅400 2

SA 3 300 Long Circular SA No Pod ∅200 1

SA 4 300 Long Circular SA No Pod ∅200 1

FC 1 Ceiling Mounted Fan ∅250 1

Checked

Designed

Scale

Drawing

A110 - Rev 1

1:100 (A0)2019-03-01

Date

Drawn

D.F.

Dwg.Description

Air-Conditioning and Ventilation

REV. NO:

Installation

Project

DESCRIPTION:DATE:1 Issue for Tender Purposes2019-03-01

Building C4 Renovations:New NTP Offices

Air-Conditioning and VentilationSpecifications & Layout

H.A.

Project Managers :

Client :

Y.J.

AutoCAD SHX Text
9500
AutoCAD SHX Text
13600
AutoCAD SHX Text
8700
AutoCAD SHX Text
800
AutoCAD SHX Text
800
AutoCAD SHX Text
1150
AutoCAD SHX Text
4200
AutoCAD SHX Text
1150
AutoCAD SHX Text
800
AutoCAD SHX Text
4900
AutoCAD SHX Text
800
AutoCAD SHX Text
800
AutoCAD SHX Text
3750
AutoCAD SHX Text
800
AutoCAD SHX Text
800
AutoCAD SHX Text
5100
AutoCAD SHX Text
800
AutoCAD SHX Text
1600
AutoCAD SHX Text
1700
AutoCAD SHX Text
3200
AutoCAD SHX Text
2200
AutoCAD SHX Text
800
AutoCAD SHX Text
800
AutoCAD SHX Text
800
AutoCAD SHX Text
1950
AutoCAD SHX Text
800
AutoCAD SHX Text
3000
AutoCAD SHX Text
2500
AutoCAD SHX Text
3400
AutoCAD SHX Text
3800
AutoCAD SHX Text
3300
AutoCAD SHX Text
2800
AutoCAD SHX Text
3300
AutoCAD SHX Text
3800
AutoCAD SHX Text
1800
AutoCAD SHX Text
1850
AutoCAD SHX Text
2585
AutoCAD SHX Text
2550
AutoCAD SHX Text
2550
AutoCAD SHX Text
855
AutoCAD SHX Text
3800
AutoCAD SHX Text
3800
AutoCAD SHX Text
a
AutoCAD SHX Text
a
AutoCAD SHX Text
a
AutoCAD SHX Text
a
AutoCAD SHX Text
a
AutoCAD SHX Text
a
AutoCAD SHX Text
a
AutoCAD SHX Text
a
AutoCAD SHX Text
C
AutoCAD SHX Text
C
AutoCAD SHX Text
C
AutoCAD SHX Text
C
AutoCAD SHX Text
a
AutoCAD SHX Text
a
AutoCAD SHX Text
a
AutoCAD SHX Text
a
AutoCAD SHX Text
a
AutoCAD SHX Text
a
AutoCAD SHX Text
a
AutoCAD SHX Text
a
AutoCAD SHX Text
a
AutoCAD SHX Text
a
AutoCAD SHX Text
a
AutoCAD SHX Text
a
AutoCAD SHX Text
a
AutoCAD SHX Text
a
AutoCAD SHX Text
a
AutoCAD SHX Text
a
AutoCAD SHX Text
a
AutoCAD SHX Text
a