Upload
others
View
6
Download
0
Embed Size (px)
Citation preview
H600/H1000 SeriesHigh Pressure In-Line Filters3
Max 1000 l/min - 414 bar
Global Filtration Technology
03 HIGH PRESSURE FILTERS 28/6/02 9:41 am Page 97
High Pressure In-Line FiltersH600/H1000 Series
TYPICAL APPLICATIONS
Drilling Rigs
Power Packs
Oil/Gas Industry
Flight Simulators
Test Rigs
The Parker Filtration Model H600/H1000 High Pressure In-Line Filters.
The H600/H1000 Series is designed to meet the growing demand for high-pressure
filters with a flow rate capacity of up to 1000 l/min at 414 bar working pressure. A
wide range of elements is available to offer system-matched protection of the hydraulic
system. For systems where reverse flow can be expected, an optional integrated reverse
flow valve avoids back wash of contamination. The elements and filter media used
include high-quality materials such as HPFE glass fibre and stainless steel mesh as well
as high strength mesh cleanable elements and high strength fibre disposable elements.
When changing the element, only the end cap of the bowl has to be removed. The filter
is ideal for applications where space is at a premium.
TYPICAL APPLICATIONS
98
03 HIGH PRESSURE FILTERS 28/6/02 9:41 am Page 98
High Pressure In-Line FiltersH600/H1000 Series
SPECIFICATION
Assembly:In-Line filter, filter housing pressure pulse fatigue test:3,000,000 cycles 0-276 bar
Operating Pressure:Max. 414 bar
Connections:Threads G11/2, G2 (ISO228), SAE 24, SAE 32, Flanges (rating6000psi) SAE 11/2”, SAE 2”
Seal Material:Nitrile, Neoprene, Fluoroelastomer
Operating Temperature Range:-40°C to 100°C
Degree of Filtration:Determined by multipass test according to ISO 16889
Filtration Media:HPFE glass fibre GDH multi layer glass fibre. (See Table A).
Flow Fatigue Characteristics:Filter media is supported so that the optimal fatigue life is achieved
Element Collapse Rating:20 bar (ISO 2941), 210 bar for high strength element
Bypass Setting:7.0 bar
Differential Pressure Indicator:5.0 barDifferential indicator visualDifferential indicator electrical
Options:Reverse flow valve
Filter Housing:Head S.G. Iron casting, Bowl extruded steel
Filter Element:Element with steel end capsHigh strength element on request only
1 Filter head2 Filter element3 Bowl seal
3A Bowl back-up ring4 Housing5 Cover6 Indicator seal7 Bypass set8 Visual indicator9 Electrical indicator10 Bypass seal11 Reverse flow set12 Adaptor13 Adaptor/reverse flow seal14 Cover seal15 Drain plug
TYPE H MODEL 1000
1
2
3/3A
3/3A
4
5
6
7
8
9
1013
11
12
14
15
Ø169
Ø125
Ø145
Ø145
107.
510
588
35
235
15
SAE 646 A/F
MIN
IMU
M E
LEM
EN
TC
LEA
RA
NC
E
330/
580
L1=
563
L2=
813
10055A/F
99
03 HIGH PRESSURE FILTERS 28/6/02 9:41 am Page 99
High Pressure In-Line FiltersH600/H1000 Series
Flow (l/min)
∆p (
bar
)
0
0.2
0.4
0.6
0.8
1
1.2
1.4
1.6
0 100 200 300 400 500 600
RFV
Flow (US GPM)
0 79 106 132 1595326
∆p (
psi
d)
0
2.9
5.8
8.7
11.6
14.5
17.4
20.3
23.2
Adapter
Flow (l/min)
∆p (
bar
)
0
0.2
0.4
0.6
0.8
1
1.2
1.4
1.6
0 100 200 300 400 500 600
GDH3
GDH6
GDH10GDH20
Flow (US GPM)
0 79 106 132 1595326
∆p (
psi
d)
0
2.9
5.8
8.7
11.6
14.5
17.4
20.3
23.2
600 Housing (G11/2”, SAE 24, SAE 11/2”)
600 ElementsFlow (l/min)
∆p (
bar
)
0
0.5
1
1.5
2
2.5
0 200 400 600 800 1000
Adapter
RFV
∆p (
psi
d)
0
7.3
14.5
21.8
29.0
36.3
Flow (US GPM)
0 106 159 211 26453
Flow (l/min)
∆p (
bar
)
0
0.5
1
1.5
2
2.5
3
0 200 400 600 800 1000
GDH3
GDH6
GDH10
GDH20
∆p (
psi
d)
0
7.3
14.5
21.8
36.3
43.5
29.0
Flow (US GPM)
0 106 159 211 26453
1000 Housing (G2”, SAE 32, SAE 2”)
1000 Elements
PRESSURE DROP CURVES
ADDITIONAL INFORMATION
CIRCUIT SYMBOL
Filter withReverse Flow Valve
Normal Flow Condition
Reverse Flow Condition
VALVE HOUSING
VALVE HOUSING
SLEEVE
CENTRAL STEM
100
03 HIGH PRESSURE FILTERS 28/6/02 9:41 am Page 100
High Pressure In-Line FiltersH600/H1000 Series
Ordering Code1074A2HN70-FZ12101074A2HN70-FZ12201074A2HN70-FZ12301074A2HN70-TZ22101074A2HN70-TZ22201074A2HN70-TZ2230
Ordering Code Flow (l/min)600600600100010001000
Flow (l/min) Micron RatingGDH 06GDH 10GDH 20GDH 06GDH 10GDH 20
Media Rating Ports11/2” SAE Flange11/2” SAE Flange11/2” SAE Flange2” SAE Flange2” SAE Flange2” SAE Flange
Ports IndicatorVisualVisualVisualVisualVisualVisual
Indicator Replacement Elements1070Z121A1070Z122A1070Z123A1070Z221A1070Z222A1070Z223A
Replacement Elements
PREFERRED PRODUCTS TABLE
ORDERING EXAMPLE
1 2 Std 8 9 10 4
Element
Filter Assembly
1 2 3 4 5 5A 6 7 8 9 10 11
10 7 4 A 2H N 70 – B Z 1 23 0
10 7 0 Z 1 23 A
Element TypeHigh strength fibre (210 bar)HPFE glass fibre GDH
CODE57
CODE10
HousingModel 1000
Element TypeFilter Type
Table 1
Table 10
Table 2
VarietyStandard flowReverse flow valve (RFV)
CODE42
Flow Direction
Table 3
OptionsStandard
CODE0
Options
Table 11
High strength fibre ßx≥ 75
GDH glass fibre ßx≥ 75
Filtration fineness
3µm
FF
20
6µm
21
10µm
22
15µm
10
20µm
23
Degree of Filtration
Seal MaterialNitrile (Buna) (NBR)Neoprene (CR)Fluoroelastomer (FPM)
CODEABH
Seal Type
Table 4
Bypass differential pressure settingNo bypassBypass setting 7.0 bar
CODE0070
Bypass Valve
Table 6
PortsISO 228- G11/2 (BSP)ISO 228- G2 (BSP)SAE 24SAE 3211/2” SAE Flange 414 bar2” SAE Flange 414 bar
CODEBESHFT
Filter Connection
Table 7
Element length600 l/min1000 l/min
CODE12
Element Length
Table 9
Element typesAll fluids exc. phosphate esters,water glycols and ammoniacontaining oils.
CODEAll
ratingsZ
Element Information
Table 8
Table 5ATable 5
Bypass typeNo bypass portBypass valveBypass valveNo bypass valve
Bypass valve
No bypass valve
Indicator code
No indicator
Standard visual indicator
Electrical Din 43650 28V=/ 250 V ~ No lampsElec./Visual indicator 250 V ~ Green lamps N.C.Elec./Visual indicator 250 V ~ Red lamps N.O.Elec./Visual indicator 110 V ~ Green lamps N.C.Elec./Visual indicator 110 V ~ Red lamps N.O.Elec./Visual indicator 28 V = Green lamps N.C.Elec./Visual indicator 28 V = Red lamps N.O.
Setting
–
5.0 bar
5.0 bar
0H1H2H4H
3H
5H
N
N
THKCMER
Bypass Indicators
Note: Filter assemblies ordered from the Part Number Matrix below are on extended lead times.Where possible, please make your selection from the table above.
Average filtration Beta Ratio (ISO 16889) / particle size µm(c)
2 10 75 100 200 1000
N/A 3.0 4.1 4.4 4.9 6.7
N/A 4.0 6.7 7.0 7.9 10.0
3.1 6.2 9.9 10.4 11.6 14.6
6.7 12.6 17.8 18.5 20.0 22.6
CODE
GDL3/GDH3
GDL6/GDH6
GDL10/GDH10
GDL20/GDH20
Degree of FiltrationTable A
101
03 HIGH PRESSURE FILTERS 28/6/02 9:41 am Page 101
18/28/38P SeriesHigh Pressure Filters
Max 520 l/min - 414 bar
Global Filtration Technology
03 HIGH PRESSURE FILTERS 24/10/02 11:13 am Page 103
High Pressure Filters18/28/38P Series
TYPICAL APPLICATIONS
Injection Moulding
Die Casting
Servo Controls
Machine Tools
Mobile Equipment
Parker Filtration engineered the 18/28/38P series of high pressure filters to
satisfy demanding applications in the mobile and industrial markets
throughout the world. With metric mounting and optional ISO 6149 ports,
this new series is truly a global design.
Installed downstream of the pump, this new series with their wide range of
high capacity Microglass III elements, offer excellent protection to system
components.
Standard filters come complete with industry proven spool type bypass
valve. For more critical applications such as servo or proportional controls, a
no bypass high strength element combination ensures maximum protection.
The modular low hysteresis differential pressure indicator fitted to this series
is unrivaled in its performance. Tests prove its accuracy and foolproof design
to be a major advance in indicator technology.
TYPICAL APPLICATIONS
104
03 HIGH PRESSURE FILTERS 24/10/02 11:13 am Page 104
High Pressure Filters18/28/38P Series
SPECIFICATION
Maximum Allowable Operating Pressure:414 bar (6000 psi). Factor safety 3:1Operating Temperature Range:-40° to 120°C (-30°F to +250°F)Materials of Construction:SG iron head, steel bowlPorts:Inlet and outlet ports are threaded internally or flange facedPort Style Model
18P 28P 38PBSPF(G) 3/4” 1” 11/4”, 11/2”SAE 12 16 20, 24ISO 6149 M27 M33 M42, M48SAE 6000-config 3/4” 1” 11/4”Metric 6000-M config* 3/4” 1” 11/4”*6000-M is SAE style with appropriate metric fixing threadsBypass Valve & Indicator Settings:Table below gives bypass valve and corresponding indicatorsettingBypass Indicator3.5 bar 2.5 bar7.0 bar 5.0 bar
Weights (kg):Model Length 1 Length 218P 4.2 5.728P 6.7 9.238P 15.8 20.3Fluid Compatibility:Suitable for use with mineral oils, most water glycols and other waterbased fluids. For other fluids, please consult Filter Division EuropeSeals:Head to bowl, diametral with anti-extrusion ring.Materials - Nitrile or Fluoroelastomer*Element Condition Indicators: (Differential Pressure Type)Cartridge type visual, with auto reset. Cartridge type electrical,with auto reset and socket to DIN43650, protection class IP65Electrical Ratings:Power - 5 VA max, Current - 0.25 A max (resistive), Voltage -28 VDC max, 28 VAC (50-60Hz) max, Contacts - normallyopen and normally closed, wired to DIN plug pin codeFilter Elements:Microglass III supported with epoxy coated steel mesh. (See Table 4).Element Collapse Rating:Standard; 20 bar differential minimum. High collapse; 210 bardifferential minimum*Fluoroelastomers are available under various registered trademarks, includingViton (a registered trademark of DuPont) and Fluorel (a registered trademark of 3M)
Model
198(7.79)293
(11.53)228
(8.97)337
(13.26)329
(12.95)448
(17.64)
32(1.26)
40(1.57)
44(1.73)
26(1.02)
29(1.14)
35(1.38)
75(2.95)
93(3.66)
128(5.04)
24(0.94)
40(1.14)
36(1.42)
100(3.94)
98(3.86)
120(4.72)
160(6.30)
40(1.57)
55(2.16)
50(1.97)
20(0.79)
27.5(1.07)
25(0.98)
80(3.15)
90(3.54)
120(4.72)
40(1.57)
45(1.77)
60(2.36)
55(2.16)
62(2.44)
81(3.19)
110(4.33)
124(4.88)
162(6.38)
M8 x 1.25x12
(0.47)deep
M10 x 1.5x11
(0.43)deep
M10 x 1.5x12
(0.47)deep
18P-1
18P-2
28P-1
28P-2
38P-1
38P-2
A B C D E F G H J K L M N P(A/ F )
18P 28P 38P
B C
Torque15-20 ft/lbs.(22-27Nm)
Single Length(A)
Double Length(B)
Hex. 23.324.0 A/FBowl Removal
F
CB
Single Length(A)
Double Length(B)
Bowl RemovalF
Hex. 23.324.0 A/F
Torque25-30 ft/lbs.(34-40 Nm)
B C
Single Length(A)
Double Length(B)
Bowl RemovalF
Torque60-70 ft/lbs.(81-95 Nm)
Hex. 35.3836.0 A/F
K
GH
J
LN
M
15°
4 Mounting Holes (P)
G
H
J
K
LM
N
4 Mounting Holes (P)
15°R30 R3
5
G
JH
NM
15°
LK
R38
4 Mounting Holes (P)
mm(inches)
D DD
105
03 HIGH PRESSURE FILTERS 24/10/02 11:13 am Page 105
Note: For full indicator specifications see Section 6.
Element Condition Indicators:
VISUAL AUTO RESETCODE M2
48 VAC ELECTRICAL VISUAL INDICATORCODE E2
FLANGE FACE DETAILS
High Pressure Filters18/28/38P Series
INDICATOR DETAILS
B
N/A
Pin 1 – CommonPin 2 – Normally ClosedPin 3 – Normally Open
N/A
2.90 (73.7)
1.44 (36.6)
1.44 (36.6)
Option Description Connection/Voltage Wiring “A” “B”
M2
E2
Visual Auto Reset
Electrical – Visual
N/A
Din 43650 3 Pole + Earth5A@48 VAC, 3A@28VDC
A
B
1
3
2
Modelmm (inches)
11.9
(0.47)
14
(0.55)
15.7
(0.62)
23.8
(0.94)
27.8
(1.09)
31.7
(1.25)
25.4
(1.00)
28.0
(1.10)
33.0
(1.30)
50.8
(2.0)
57.1
(2.25)
66.7
(2.62)
M10 x 1.5-6H x 18 Deep
M12 x 1.75-6H x 20 Deep
M14 x 2-6H x 20 Deep
3/8-16 UNC-2B x 18 Deep
7/16-14 UNC-2B x 20 Deep
1/2-13 UNC-2B x 20 Deep
19.0
(0.75)
25.4
(1.0)
31.8
(1.25)
18P
28P
38P
A B C D E F G
C
D
AB
Ø G
Thread E metricF SAE
106
03 HIGH PRESSURE FILTERS 24/10/02 11:13 am Page 106
High Pressure Filters18/28/38P Series
18P-1 Empty Housing and High Collapse
28P-1 Element Only
18P-1 Element Only
18P-2 High Collapse Elements Only
28P-2 Element Only
43.5
29.0
0
0 5 11 21
Flow (US GPM)
Flow (l/min)20 40 8060
0.0
∆p (
bar
)
20QH1.0
2.0
3.0
0
0.5
1.5
2.5
16
14.5
∆p (
psi
d)
10QH
05QH
02QH
Empty Housing
100
26
43.5
29.0
0
0 5 11 21
Flow (US GPM)
Flow (l/min)20 40 8060
0.0
∆p (
bar
)
20QH
1.0
2.0
3.0
0
0.5
1.5
2.5
16
14.5
∆p (
psi
d)
10QH
05QH
02QH
100
26
43.5
29.0
0
0 13 26 66
Flow (US GPM)
Flow (l/min)50 100 250200
0.0
∆p (
bar
)
20Q
1.0
2.0
3.0
0
0.5
1.5
2.5
53
14.5
∆p (
psi
d)10Q
05Q02Q
150 300
39 79
43.5
29.0
0
0 5 11 21
Flow (US GPM)
Flow (l/min)20 40 8060
0.0
∆p (
bar
)
20Q1.0
2.0
3.0
0
0.5
1.5
2.5
16
14.5
∆p (
psi
d)
10Q
05Q
02Q
100
26
18P-2 Element Only
43.5
29.0
0
0 5 11 21
Flow (US GPM)
Flow (l/min)20 40 8060
0.0
∆p (
bar
)
20Q
1.0
2.0
3.0
0
0.5
1.5
2.5
16
14.5
∆p (
psi
d)
10Q
05Q
02Q
100
26
43.5
29.0
0
0 13 26 66
Flow (US GPM)
Flow (l/min)50 100 250200
0.0
∆p (
bar
)
20Q1.0
2.0
3.0
0
0.5
1.5
2.5
53
14.5∆p
(p
sid
)10Q
05Q
02Q
150 300
39 79
28P-1 Empty Housing and High Collapse 28P-2 High Collapse Elements Only
43.5
29.0
0
0 13 26 66
Flow (US GPM)
Flow (l/min)50 100 250200
0.0
∆p (
bar
)
20QH
1.0
2.0
3.0
0
0.5
1.5
2.5
53
14.5
∆p (
psi
d)
10QH05QH
02QH
150 300
39 79
Empty Housing
43.5
29.0
0
0 13 26 66
Flow (US GPM)
Flow (l/min)50 100 250200
0.0
∆p (
bar
) 20QH
1.0
2.0
3.0
0
0.5
1.5
2.5
53
14.5
∆p (
psi
d)
10QH05QH02QH
150 300
39 79
PRESSURE DROP CURVESIf the medium used has a viscosity different from 30 cSt, pressure drop over the filter can be estimated as follows :-
p = ( p30 x viscosity of medium used) / 30 cSt
107
03 HIGH PRESSURE FILTERS 24/10/02 11:13 am Page 107
High Pressure Filters18/28/38P Series
38P-1 Empty Housing and High Collapse
38P-1 Element Only
38P-2 High Collapse Elements Only
43.5
29.0
0
0 26 53 132
Flow (US GPM)
Flow (l/min)100 200 500400
0.0
∆p (
bar
)
20QH
1.0
2.0
3.0
0
0.5
1.5
2.5
106
14.5
∆p (
psi
d)
10QH05QH
02QH
300
79
Empty Housing
159
600
43.5
29.0
0
0 26 53 132
Flow (US GPM)
Flow (l/min)100 200 500400
0.0
∆p (
bar
) 20QH
1.0
2.0
3.0
0
0.5
1.5
2.5
106
14.5
∆p (
psi
d)
10QH
05QH
02QH
300
79 159
600
43.5
29.0
0
0 26 53 132
Flow (US GPM)
Flow (l/min)100 200 500400
0.0
∆p (
bar
)
20Q1.0
2.0
3.0
0
0.5
1.5
2.5
106
14.5
∆p (
psi
d)
10Q
05Q02Q
300
79 159
600
38P-2 Element Only
43.5
29.0
0
0 26 53 132
Flow (US GPM)
Flow (l/min)100 200 500400
0.0
∆p (
bar
)
20Q
1.0
2.0
3.0
0
0.5
1.5
2.5
106
14.5
∆p (
psi
d)
10Q
05Q
02Q
300
79 159
600
02Q05Q10Q20Q
02QH05QH10QH20QH
74
78
67
60
57
61
56
54
111
105
101
100
87
88
80
78
28
28
24
24
24
27
23
22
48
50
48
48
38
38
38
37
7.4
9.4
8.0
8.6
6.3
8.8
7.2
7.2
22.7
23.5
17.2
17.7
17.8
19.6
16.1
12.6
Media 38P-1 38P-2 28P-1 28P-2 18P-1 18P-2Code (98 psid) (98 psid) (98 psid) (98 psid) (98 psid) (98 psid)
CAPACITY IN GRAMS
108
03 HIGH PRESSURE FILTERS 24/10/02 11:13 am Page 108
High Pressure Filters18/28/38P Series
Element ServiceA. Stop the system s power unit.
B. Relieve any system pressure in the filter line.
C. Drain the filter bowl if drain port option is provided.
D. Rotate the bowl clockwise (left) and remove.
E. Remove element by pulling downward with a slight twisting motion
and discard.
F. Check bowl o-ring and anti-extrusion ring for damage and replace
if necessary.
G. Lubricate element o-ring with system fluid and locate element in
filter head.
H. Install bowl by rotating counter-clockwise (right) and tighten to
specified torque.
18P — 15-20ft. lbs (22-27 Nm)
28P — 25-30ft. lbs (34-40 Nm)
38P — 60-70ft. lbs (81-95 Nm)
I. Confirm there are no leaks after powering the system.
Head AssemblyElementBowlSingle lengthDouble lengthIndicatorsM2 – Visual autoresetE2 – Elecrical/Visualw/DIN connectionBowl SealBowl Anti-extrusion Ring*Seal Kit – (Nitrile)*Seal Kit – (Fluoroelastomer)
123
45
67
Index Description
Parts List
6
7
3
2
1
5
4
109
* Includes bowl o-ring, bowl anti-extrusion washerand indicator o-rings
03 HIGH PRESSURE FILTERS 24/10/02 11:13 am Page 109
Part Number18P-1-02Q-M2-98-B2B2-118P-1-05Q-M2-98-B2B2-118P-1-10Q-M2-98-B2B2-118P-1-20Q-M2-98-B2B2-118P-2-02Q-M2-98-B2B2-118P-2-05Q-M2-98-B2B2-118P-2-10Q-M2-98-B2B2-118P-2-20Q-M2-98-B2B2-128P-1-02Q-M2-98-C2C2-128P-1-05Q-M2-98-C2C2-128P-1-10Q-M2-98-C2C2-128P-1-20Q-M2-98-C2C2-128P-2-02Q-M2-98-C2C2-128P-2-05Q-M2-98-C2C2-128P-2-10Q-M2-98-C2C2-128P-2-20Q-M2-98-C2C2-138P-1-02Q-M2-98-D2D2-138P-1-05Q-M2-98-D2D2-138P-1-10Q-M2-98-D2D2-138P-1-20Q-M2-98-D2D2-138P-2-10Q-M2-98-D2D2-1
Part Number18P-1-02Q-E2-98-B2B2-118P-1-05Q-E2-98-B2B2-118P-1-10Q-E2-98-B2B2-118P-1-20Q-E2-98-B2B2-118P-2-02Q-E2-98-B2B2-118P-2-05Q-E2-98-B2B2-118P-2-10Q-E2-98-B2B2-118P-2-20Q-E2-98-B2B2-128P-1-02Q-E2-98-C2C2-128P-1-05Q-E2-98-C2C2-128P-1-10Q-E2-98-C2C2-128P-1-20Q-E2-98-C2C2-128P-2-02Q-E2-98-C2C2-128P-2-05Q-E2-98-C2C2-128P-2-10Q-E2-98-C2C2-128P-2-20Q-E2-98-C2C2-138P-1-02Q-E2-98-D2D2-138P-1-05Q-E2-98-D2D2-138P-1-10Q-E2-98-D2D2-138P-1-20Q-E2-98-D2D2-138P-2-10Q-E2-98-D2D2-1
Flow (l/min)356090
100609011013080
100150200120160200240130250360450500
Media Rating02Q05Q10Q20Q02Q05Q10Q20Q02Q05Q10Q20Q02Q05Q10Q20Q02Q05Q10Q20Q10Q
PortsG3/4
G3/4
G3/4
G3/4
G3/4
G3/4
G3/4
G3/4
G1G1G1G1G1G1G1G1
G11/4
G11/4
G11/4
G11/4
G11/4
Replacement ElementsG04242G04243G04244G04245G04250G04251G04252G04253G04258G04259G04260G04261G04266G04267G04268G04269G04274G04275G04276G04277G04284
PREFERRED PRODUCTS TABLE
The following filters are supplied with 7.0 bar bypass and Nitrile seals.
High Pressure Filters18/28/38P Series
PART NUMBER MATRIXTable 1 Table 2 Table 3 Table 4 Table 5 Table 6 Table 7 Table 8 Table 9
F3 28P 1 10Q M2 98 C2C2 1 –
Note: Indicator Differential Pressure Settings2.5 bar with 3.5 bar bypass5.0 bar with 7.0 bar bypass5.0 bar with no bypass
MODEL18P
28P
38P
SYMBOLB2B2M4M4B3B3Y3Y3
Y9Y9
C2C2N4N4C3C3Y3Y3
Y9Y9
D2D2E2E2O4O4P4P4D3D3E3E3Y3Y3
Y9Y9
DescriptionG3/4” Thread12, SAE ThreadM27, ISO 61493/4” 6000-M Flange Face3/4” 6000-M Config.Flange FaceG116 SAE ThreadM33, ISO 61491” 6000-M Flange Face1” 6000-M Config.Flange FaceG11/4” ThreadG11/2” Thread20 SAE Thread24 SAE ThreadM42, ISO 6149M48, ISO 614911/4” 6000-M Flange Face11/4” 6000-M Config.Flange Face
SYMBOL
N
M2
V6
E2
TW6
FW6
Description
None
Visual (Auto reset)
FPC Visual (Auto reset)
Visual Electrical Din Plug
FPC Electrical Din Plug
FPC Electronic L.E.D.
SYMBOLOF3
DescriptionNitrileFluoroelastomer*
PortsIndicator OptionsSeals
Table 1
SYMBOL12
DescriptionSingle LengthDouble Length
Housing Length
Table 3
Symbol18P28P38P
Model Number
Table 2 Table 5 Table 7
SYMBOL5098X
Description3.5 bar7.0 barNo bypass
Bypass Indicator Setting
Table 6
SYMBOLIII
DescriptionNoneNo Bypass
Options
Table 8
Applied to the filter assembly by ParkerFiltration.
Design Number
Table 9
Note: Filter assemblies ordered from the Part Number Matrix below are on extended lead times.Where possible, please make your selection from the table above.
Table 4
Average filtration ratio ß (ISO 16889) / particle size µm(c)
2 10 75 100 200 1000
N/A N/A N/A N/A N/A 4.5
N/A N/A 4.5 5 6 7
N/A 6 8.5 9 10 12
6 11 17 18 20 22
CODE
02Q
02QH
05Q
05QH
10Q
10QH
20Q
20QH
Degree of Filtration
110
03 HIGH PRESSURE FILTERS 24/10/02 11:13 am Page 110
7000 SeriesHigh Pressure Filters
Max 450 l/min - 420 bar
Global Filtration Technology
FEATURING
03 HIGH PRESSURE FILTERS 24/10/02 11:13 am Page 111
With the courtesy of:Kalmar Industries Inc.
With the courtesy of:Ponsse Oyj
High Pressure Filters7000 Series
TYPICAL APPLICATIONS
Forestry Equipment
Industrial Power Units
Pulp and Paper
Port Handling Equipment
Mining and Quarrying Equipment
The Parker Filtration 7000 Series HighPressure Filter Range.
High quality 420 bar in-line pressure
filters designed to offer high levels of
protection at flows up to 450 l/min
Dirt sensitive systems can be protected
with confidence using the 7000 Series
high pressure filters.
TYPICAL APPLICATIONS
112
03 HIGH PRESSURE FILTERS 24/10/02 11:13 am Page 112
High Pressure Filters7000 Series
SPECIFICATION
Assembly:In-line filter
Operating Pressure:Max 420 bar, type 7008: 350 bar, filter housing pressure pulsefatigue tested: 106 pulses 0-414 bar
Connections:Threads G1, G11/4, G11/2 (ISO 228/1) or flanges 11/2” SAE 3000psi, 11/2 SAE 6000 psi, 11/4” SAE 6000 psi
Seal Material:Nitrile (ordering B code) or Fluoroelastomer (ordering code V)
Operating Temperature Range:-20° to +100°C
Degree of Filtration:Determined by multipass test according to ISO 16889
Filtration Media:Microglass III supported with epoxy coated metal wire mesh orEcoglass III supported with plastic net (no metallic parts)(See table 2)
Flow Fatigue Characteristics:Filter media is supported so that the optimal fatigue life isachieved (ISO 3724)
Bypass Valve:Opening pressure 3.5 bar or optionally no bypass valve
Indicator Options:Indicating differential pressure:2.5 ± 0.2 bar or 7.0 ± 0.5 bar; 2.5 bar indicators to be used with3.5 bar bypass valve and 7.0 bar indicators with no bypass option
– electronic indicator FPC.F (10 to 36 VDC)– electrical indicator FPC.T (max 250 VAC)– visual indicator (FPC.V)
Indicator Housing:Standard material brass. Max torque 15Nm (11.25 Ft lbs)
Filter Housing:Head material, cast iron (GSI). Bowl material steel. Max torque 40Nm (30 Ft lbs)
Filter Element; and Collapse Ratings:7000 Series (Q0XX)Microglass III media, end cap material reinforced composite(code K) and metal inner core. Collapse rating 20 bar (ISO2941).
7000 Eco (QEXX)Ecoglass III media, end cap material reinforced composite (codeK), no metallic parts. Filter element can only be used together withre-usable FEA Eco-adaptor. Collapse rating 10 bar (ISO 2941).
Note: Ecoglass III elements contributes to ISO 14001 quality standards
7000 High Collapse Element (A0XX)(to be used when no bypass function in filter housing)Microglass III media supported with epoxy coated steel wire onupstream and stainless steel wire on downstream side. End cap material
With the courtesy of:Sandvik Tamrock
113
03 HIGH PRESSURE FILTERS 24/10/02 11:13 am Page 113
High Pressure Filters7000 Series
SPECIFICATION
7005700670077008
116 (4.57)208 (8.19)329 (12.95)428 (16.85)
249 (9.80)342 (13.46)462 (18.19)562 (22.12)
295 (11.61)390 (15.35)510 (20.08)610 (24.01)
235 (9.25)330 (13.00)450 (17.72)550 (21.65)
420 bar(6000 psi)
350 bar (5000 psi)
G1, G11/4 or G11/2
Flange: SAE 11/2 3000 psiFlange: SAE 11/2 6000 psiFlange: SAE 11/4 6000 psi
TYPE A B B B M AX WORKING PORTPRESSURE D(block
assembly) L PORTT PORT
BLOCK ASSEMBLY T PORT L PORT
62(2.44)
129(5.08)
60
B
41 HEX(1.61)
A
OUT
IN
D
137(5.39)
43(1.69)
M10 DEPTH 20 (0.78)
NOTE: NOFASTENING HOLESWITH SAEFLANGEOPTION
OUT IN
D D
OPTION (FOR ALL MODELS)PLUG M12x1.5
PLUG M12x1.5
M10 DEPTH 10
B
VENT PORT
p INDICATOR
30(1.18)
140
INTERNAL DIA. 32/EXTERNAL DIA. 41
4 MOUNTING HOLES 21 DIA.
OUTLET
O-RING SIZE 220
52(2.04)
190(7.48)
58
B
INLET
60(2.36) 41 HEX
(1.61)
137(5.39)
144
(5.6
7)
100
(3.9
4)
56(2.20)
OPTIONALINDICATORPORT
D
Ø103(4.05)
142(5.60)
mm(inches)
953.74
43(1.69)
114
03 HIGH PRESSURE FILTERS 24/10/02 11:13 am Page 114
Electronic & Electrical DifferentialPressure Indicator
CODE FPC.F & FPC.T
Visual DifferentialPressure Indicator
CODE FPC.V
High Pressure Filters7000 Series
INDICATOR DETAILS
70(2.75) 29
(1.14)
N/A
N/A
FPC.F25.BM
FPC.T25.VM
FPC.V25.BM
FPC.F70.BM
FPC.T70.VM
FPC.V70.BM
Option Description Connection/Voltage Wiring P/N
F25
T25
V25
F70
T70
V70
Electronic Indicator(2.5 bar)
Electrical Indicator(2.5 bar)
Visual Indicator(2.5 bar)
Electronic Indicator(7.0 bar)
Electrical Indicator(7.0 bar)
Visual Indicator(7.0 bar)
+10 to 36 VDC
Max 250 VACMax 250 VDC
N/A
+10 to 36 VDC
Max 250 VACMax 250 VDC
N/A
Load
Load
+V
0Vmax 300 mA -10...36 VDC
+10...36 VDC
3
1
2
4
FPC.FNPNNormallyopen(N.O.)
Load
Load
+V
0Vmax 300 mA -10...36 VDC
+10...36 VDC
3
1
2
4
FPC.FPNPNormallyopen(N.O.)
Load
Load
+V
0Vmax 300 mA -10...36 VDC
+10...36 VDC
3
1
2
4
FPC.FNPNNormallyopen(N.O.)
Load
Load
+V
0Vmax 300 mA -10...36 VDC
+10...36 VDC
3
1
2
4
FPC.FPNPNormallyopen(N.O.)
NoConnect
P1-P2
Pin 2 3 1
COM
Indi
catio
n (N
.O.)
Norm
ally
Clos
ed (N
.C.)
NoConnect
P1-P2
Pin 2 3 1
COM
Indi
catio
n (N
.O.)
Norm
ally
Clos
ed (N
.C.)
Note: For full indicator specifications see Section 6.
115
03 HIGH PRESSURE FILTERS 24/10/02 11:13 am Page 115
7005 Series with Microglass III Elements
7007 Series with Microglass III Elements
7000 Series Filter Housing
7006 Series with Microglass III Elements
7008 Series with Microglass III Elements
High Pressure Filters7000 Series
PRESSURE DROP CURVESIf the medium used has a viscosity different from 30 cSt, pressure drop over the filter can be estimated as follows :-
p = ( p30 x viscosity of medium used) / 30 cSt
0
0.2
0.4
0.6
0.8
1
1.2
1.4
0 50 100 150 200 250 300 350 400 450 500Flow (l/min)
Q002
∆p (
bar
)
Q005 Q010 Q020
∆p (
psi
d)
0
2.9
5.8
8.7
11.6
14.5
17.4
20.3
Flow (US GPM)
0 13 26 39 53 66 79 92 106 119 132
0
0.2
0.4
0.6
0.8
1
1.2
1.4
0 50 100 150 200 250 300 350 400 450 500Flow (l/min)
Q002
∆p (
bar
)
Q005
Q010
Q020
∆p (
psi
d)
0
2.9
5.8
8.7
11.6
14.5
17.4
20.3
Flow (US GPM)
0 13 26 39 53 66 79 92 106 119 132
0
0.2
0.4
0.6
0.8
1
1.2
1.4
0 50 100 150 200 250 300 350 400 450 500Flow (l/min)
Q002
∆p (
bar
)
Q005
Q010
Q020 ∆p (
psi
d)
0
2.9
5.8
8.7
11.6
14.5
17.4
20.3
Flow (US GPM)
0 13 26 39 53 66 79 92 106 119 132
GT24
GL24
GT16
GL16GT20
GL20Block
0 50 100 150 200 250 300 350 400 450 500
Flow (l/min)
∆p (
bar
)
0
0.2
0.4
1.4
1.2
1
0.6
0.8
Flow (US GPM)
0 53 79 106 13226
∆p (
psi
d)
0
2.9
5.8
11.6
17.4
20.3
14.5
11992663913
8.7
0
0.2
0.4
0.6
0.8
1
1.2
1.4
0 50 100 150 200 250 300 350 400 450 500Flow (l/min)
Q002
∆p (
bar
) Q005Q010
Q020 ∆p (
psi
d)
Flow (US GPM)
0
2.9
5.8
8.7
11.6
14.5
17.4
20.30 13 26 39 53 66 79 92 106 119 132
116
03 HIGH PRESSURE FILTERS 24/10/02 11:13 am Page 116
High Pressure Filters7000 Series
PRESSURE DROP CURVESIf the medium used has a viscosity different from 30 cSt, pressure drop over the filter can be estimated as follows :-
p = ( p30 x viscosity of medium used) / 30 cSt
7005 Series with Ecoglass III Elements
7007 Series with Ecoglass III Elements 7008 Series with Ecoglass III Elements
7006 Series with Ecoglass III Elements
0
0.2
0.4
0.6
0.8
1
1.2
1.4
0 50 100 150 200 250 300 350 400 450 500Flow (l/min)
QE02
∆p (
bar
)
QE05
QE10QE20
∆p (
psi
d)
0
2.9
5.8
8.7
11.6
14.5
17.4
20.3
Flow (US GPM)
0 13 26 39 53 66 79 92 106 119 132
0
0.2
0.4
0.6
0.8
1
1.2
1.4
0 50 100 150 200 250 300 350 400 450 500Flow (l/min)
QE02
∆p (
bar
)
QE05QE10
QE20
∆p (
psi
d)
0
2.9
5.8
8.7
11.6
14.5
17.4
20.3
Flow (US GPM)
0 13 26 39 53 66 79 92 106 119 132
0
0.2
0.4
0.6
0.8
1
1.2
1.4
0 50 100 150 200 250 300 350 400 450 500Flow (l/min)
QE02
∆p (
bar
) QE05
QE10
QE20
∆p (
psi
d)
0
2.9
5.8
8.7
11.6
14.5
17.4
20.3
Flow (US GPM)
0 13 26 39 53 66 79 92 106 119 132
0
0.2
0.4
0.6
0.8
1
1.2
1.4
0 50 100 150 200 250 300 350 400 450 500
Flow (l/min)
QE02
∆p (
bar
) QE05
QE10
QE20
∆p (
psi
d)
0
2.9
5.8
8.7
11.6
14.5
17.4
20.3
Flow (US GPM)
0 13 26 39 53 66 79 92 106 119 132
117
03 HIGH PRESSURE FILTERS 24/10/02 11:13 am Page 117
Part Number
L-PORT
FF7005.Q005.BS35.GL16
FF7005.Q005.BS35.GL20
FF7005.Q010.BS35.GL16
FF7005.Q010.BS35.GL20
FF7005.Q020.BS35.GL16
FF7005.Q020.BS35.GL20
FF7006.Q005.BS35.GL16
FF7006.Q005.BS35.GL20
FF7006.Q010.BS35.GL16
FF7006.Q010.BS35.GL20
FF7006.Q020.BS35.GL16
FF7006.Q020.BS35.GL20
FF7007.Q005.BS35.GL20
FF7007.Q005.BS35.GL24
FF7007.Q010.BS35.GL20
FF7007.Q010.BS35.GL24
FF7007.Q020.BS35.GL20
FF7007.Q020.BS35.GL24
FF7008.Q005.BS35.GL24
FF7008.Q010.BS35.GL24
FF7008.Q020.BS35.GL24
T-PORT
FF7005.Q005.BS35.GT16
FF7005.Q005.BS35.GT20
FF7005.Q010.BS35.GT16
FF7005.Q010.BS35.GT20
FF7005.Q020.BS35.GT16
FF7005.Q020.BS35.GT20
FF7006.Q005.BS35.GT20
FF7006.Q010.BS35.GT20
FF7006.Q010.BS35.GT24
FF7006.Q020.BS35.GT20
FF7006.Q020.BS35.GT24
FF7007.Q005.BS35.GT24
FF7007.Q010.BS35.GT24
FF7007.Q020.BS35.GT24
FF7008.Q005.BS35.GT24
FF7008.Q010.BS35.GT24
FF7008.Q020.BS35.GT24
Flow (l/min)
90
90
120
120
140
140
150
150
200
220
220
240
200
220
240
300
240
380
250
380
450
90
90
120
120
140
140
150
200
230
220
270
220
270
300
250
280
320
Media Rating
Q005
Q005
Q010
Q010
Q020
Q020
Q005
Q005
Q010
Q010
Q020
Q020
Q005
Q005
Q010
Q010
Q020
Q020
Q005
Q010
Q020
Q005
Q005
Q010
Q010
Q020
Q020
Q005
Q010
Q010
Q020
Q020
Q005
Q010
Q020
Q005
Q010
Q020
Ports
G1
G11/4
G1
G11/4
G1
G11/4
G1
G11/4
G1
G11/4
G1
G11/4
G11/4
G11/2
G11/4
G11/2
G11/4
G11/2
G11/2
G11/2
G11/2
G1
G11/4
G1
G11/4
G1
G11/4
G11/4
G11/4
G11/2
G11/4
G11/2
G11/2
G11/2
G11/2
G11/2
G11/2
G11/2
Replacement Elements
FC7005.Q005.BK
FC7005.Q005.BK
FC7005.Q010.BK
FC7005.Q010.BK
FC7005.Q020.BK
FC7005.Q020.BK
FC7006.Q005.BK
FC7006.Q005.BK
FC7006.Q010.BK
FC7006.Q010.BK
FC7006.Q020.BK
FC7006.Q020.BK
FC7007.Q005.BK
FC7007.Q005.BK
FC7007.Q010.BK
FC7007.Q010.BK
FC7007.Q020.BK
FC7007.Q020.BK
FC7008.Q005.BK
FC7008.Q010.BK
FC7008.Q020.BK
FC7005.Q005.BK
FC7005.Q005.BK
FC7005.Q010.BK
FC7005.Q010.BK
FC7005.Q020.BK
FC7005.Q020.BK
FC7006.Q005.BK
FC7006.Q010.BK
FC7006.Q010.BK
FC7006.Q020.BK
FC7006.Q020.BK
FC7007.Q005.BK
FC7007.Q010.BK
FC7007.Q020.BK
FC7008.Q005.BK
FC7008.Q010.BK
FC7008.Q020.BK
PREFERRED PRODUCTS TABLEThe following standard filters are supplied with 3.5 bar bypass and Nitrile seals.NB An indicator if required should be ordered separately.
High Pressure Filters7000 Series
118
03 HIGH PRESSURE FILTERS 24/10/02 11:13 am Page 118
PREFERRED PRODUCTS TABLE
High Pressure Filters7000 Series
Part Number
L-PORT
FF7005.QE05.BS35.GL16
FF7005.QE05.BS35.GL20
FF7005.QE10.BS35.GL16
FF7005.QE10.BS35.GL20
FF7005.QE20.BS35.GL16
FF7005.QE20.BS35.GL20
FF7006.QE05.BS35.GL16
FF7006.QE05.BS35.GL20
FF7006.QE10.BS35.GL16
FF7006.QE10.BS35.GL20
FF7006.QE20.BS35.GL16
FF7006.QE20.BS35.GL20
FF7007.QE05.BS35.GL20
FF7007.QE05.BS35.GL24
FF7007.QE10.BS35.GL20
FF7007.QE10.BS35.GL24
FF7007.QE20.BS35.GL20
FF7007.QE20.BS35.GL24
FF7008.QE05.BS35.GL24
FF7008.QE10.BS35.GL24
FF7008.QE20.BS35.GL24
T-PORT
FF7005.QE05.BS35.GT16
FF7005.QE05.BS35.GT20
FF7005.QE10.BS35.GT16
FF7005.QE10.BS35.GT20
FF7005.QE20.BS35.GT16
FF7005.QE20.BS35.GT20
FF7006.QE05.BS35.GT20
FF7006.QE10.BS35.GT20
FF7006.QE10.BS35.GT24
FF7006.QE20.BS35.GT20
FF7006.QE20.BS35.GT24
FF7007.QE05.BS35.GT24
FF7007.QE10.BS35.GT24
FF7007.QE20.BS35.GT24
FF7008.QE05.BS35.GT24
FF7008.QE10.BS35.GT24
FF7008.QE20.BS35.GT24
Flow (l/min)
90
90
120
120
140
140
150
150
200
220
220
240
200
220
240
300
240
380
250
380
450
90
90
120
120
140
140
150
200
230
220
270
220
270
300
250
280
320
Media Rating
Q005
Q005
Q010
Q010
Q020
Q020
Q005
Q005
Q010
Q010
Q020
Q020
Q005
Q005
Q010
Q010
Q020
Q020
Q005
Q010
Q020
Q005
Q005
Q010
Q010
Q020
Q020
Q005
Q010
Q010
Q020
Q020
Q005
Q010
Q020
Q005
Q010
Q020
Ports
G1
G11/4
G1
G11/4
G1
G11/4
G1
G11/4
G1
G11/4
G1
G11/4
G11/4
G11/2
G11/4
G11/2
G11/4
G11/2
G11/2
G11/2
G11/2
G1
G11/4
G1
G11/4
G1
G11/4
G11/4
G11/4
G11/2
G11/4
G11/2
G11/2
G11/2
G11/2
G11/2
G11/2
G11/2
Replacement Elements
FC7005.QE05.BK
FC7005.QE05.BK
FC7005.QE10.BK
FC7005.QE10.BK
FC7005.QE20.BK
FC7005.QE20.BK
FC7006.QE05.BK
FC7006.QE05.BK
FC7006.QE10.BK
FC7006.QE10.BK
FC7006.QE20.BK
FC7006.QE20.BK
FC7007.QE05.BK
FC7007.QE05.BK
FC7007.QE10.BK
FC7007.QE10.BK
FC7007.QE20.BK
FC7007.QE20.BK
FC7008.QE05.BK
FC7008.QE10.BK
FC7008.QE20.BK
FC7005.QE05.BK
FC7005.QE05.BK
FC7005.QE10.BK
FC7005.QE10.BK
FC7005.QE20.BK
FC7005.QE20.BK
FC7006.QE05.BK
FC7006.QE10.BK
FC7006.QE10.BK
FC7006.QE20.BK
FC7006.QE20.BK
FC7007.QE05.BK
FC7007.QE10.BK
FC7007.QE20.BK
FC7008.QE05.BK
FC7008.QE10.BK
FC7008.QE20.BK
ECO Range
Note: Filter assemblies ordered from the Part Number Matrix on the next page are on extendedlead times. Where possible, please make your selection from the tables above and on theprevious page.
119
03 HIGH PRESSURE FILTERS 24/10/02 11:13 am Page 119
FB block assembly XC32
High Pressure Filters7000 Series
Filter Assembly:
Filter Element:
p Indicator:
Eco-adaptor:
Seal Kit:
FEA
FPC
FC
FF** Block assy = FB
PART NUMBER MATRIXTable 1 Table 2 Table 3 Table 4 Table 5 Table 6
Table 1 Table 2 Table 3
Table 8 Table 7M
Table 1 Table 3
FD7000-Table 3
Indicator Type Options*
Visual indicator2.5 bar
Electronic indicator2.5 bar (10...36 VDC)
Electrical indicator2.5 bar (max 250 VAC)
Visual indicator7.0 bar
Electronic indicator7.0 bar (10...36 VDC)
Electrical indicator7.0 bar (max 250 VAC)
CODE
V25
F25
T25
V70
F70
T70
CODE3500
Connection Type, T-model3.5 barNO BYPASS
CODEBV
Seal MaterialNitrileFluoroelastomer
CODEL
GL16GL20GL24SL24VL24VL20
TGT16GT20GT24ST24VT24VT16
Connection Type Options,Filter HousingG1 ThreadG11/4 ThreadG11/2 ThreadFlange 11/2” SAE, 3000 psiFlange 11/2” SAE, 6000 psiFlange 11/4” SAE, 6000 psi
CODE*
A005A010A020
QE02QE05QE10QE20
Q002Q005Q010Q020
Average filtration ratio ß (ISO 16889) / particle size µm(c)2 10 75 100 200 1000
N/A N/A N/A N/A N/A 4.5N/A N/A 4.5 5 6 7N/A 6 8.5 9 10 126 11 17 18 20 22
CODE7005700670077008
Element Length116mm208mm329mm428mm
p Indicator
Bypass Valve Filter Connection
Seal Type (Filter)Degree of FiltrationFilter Type
Table 1 Table 2 Table 3
Table 5
CODEBV
Indicator OptionV25, F25, V70, F70T25, T70
Seal MaterialNitrileFluoroelastomer
Seal Type (Indicator)*
Table 7
*Standard options.For other options contact Parker Filtration
ORDERING EXAMPLES:Please note that when choosing the right size of the filter assembly, choose first the desired connectionsand the degree of filtration. The element length (Table 1) can be decided last according to the p demandsof the system.
COMPLETE FILTER: FF7007.Q010.BS35.GL20This code is for complete filter assembly with 329mm long element made of Microglass III/Q010 filtermedia, supported with epoxy coated metal wire mesh and metal inner core. Seal material is nitrile and thefilter housing is steel. Filter includes 3.5 bar bypass valve and G11/4 threads for connection. Degree offiltration see Table 2.
FILTER ELEMENT: FC7005.QE02.VKThis filter element is 116mm long with FEA adaptor and it is made of Ecoglass III/QE02 filter media. Theseal material is fluoroelastomer and element caps are of re-inforced composite.
For additional drain and vent plug options, please contact Parker Filtration.
Table 4
–IS
Standard on topOn side only
Indicator Port Position T-Model
Table 6
Table 8
K (S FOR 210 BAR ELEMENT)
S —
*Note: When using Eco-element Eco-adapter FEA is required *Q0XX = Microglass III: conventional element, collapse rating 20 bar
QEXX = Ecoglass III: Eco-element without metallic parts, collapse rating 10 barA0XX = Microglass III: high collapse element, collapse rating 210 bar
*7.0 bar indicator for use without bypass valve
120
03 HIGH PRESSURE FILTERS 24/10/02 11:13 am Page 120
HPA SeriesMini Pressure Filters
Max 33 l/min - 280 bar
Global Filtration Technology
03 HIGH PRESSURE FILTERS 24/10/02 11:13 am Page 127
Mini Pressure FiltersHPA Series
TYPICAL APPLICATIONS
Low Flow Servo Systems
Pilot Lines
Small Mobile Equipment
Lubrication Systems
High Pressure Water Systems
The Parker Filtration HPA Series MiniPressure Filters.
Small and easy to install, the Mini Pressure
Filter is a robust solution to the low flow
applications that larger filters are unable to
effectively handle.
Made from high strength brass stampings and
supplied with a wide range of media options,
reliable, high efficiency protection is the result
of using the Mini Pressure Filter.
TYPICAL APPLICATIONS
The machine pictured is the“Compact 40” precinct
sweeper from the JohnstonCompact range of self
propelled suction sweepers.Photograph courtesy of
Johnston Engineering Ltd.
Alternative head mounting.For details please contactParker Filtration.
Photographs courtesy ofNifty Lift Ltd.
128
03 HIGH PRESSURE FILTERS 24/10/02 11:13 am Page 128
Mini Pressure FiltersHPA Series
SPECIFICATION
INSTALLATION DETAILS (FOR NEW HEAD DETAILS CONSULT PARKER FILTRATION)
Construction:Brass stampings
Max. working pressure:280 bar
Working temperature:-30°C to +90°C
Thread:G1/4 and G3/8
Filtration media:Microglass III; see Table A10µ, 25µ, 40µ, 80µ and 125µ (nominal) stainless steel
Seals:Nitrile/Nitrile composite
Weight:Length 1: 0.88 KgLength 2: 1.2 Kg
Note: For Length 1 and Length 2 filter housing and element media pressure drop against flow curves consult Parker Filtration.
Length 1 Length 2
CIRCUIT SYMBOL
29
22 A/F HEX
6248
8237
1611.1
62.7
INLET PORT G1/4 OUTLET PORT G1/419
MIN
IMUM
FO
RBO
WL
REM
OVA
L
63
21 A/F
G3/8
Ø48
Ø62
1913
8
37
11
129
03 HIGH PRESSURE FILTERS 24/10/02 11:13 am Page 129
PREFERRED PRODUCTS TABLE
Mini Pressure FiltersHPA Series
Consult Parker Filtration for
flow specifications
HPR.1229
HPR.1329
HPR.1429
HPR.1529
HPR.1629
HPR.1729
HPR.1829
HPR.1929
2µ Absolute pressure filter
3µ Absolute pressure filter
5µ Absolute pressure filter
10µ Absolute pressure filter
25µ Absolute pressure filter
40µ Absolute pressure filter
80µ Absolute pressure filter
125µ Absolute pressure filter
HPA.2225.100
HPA.2325.100
HPA.2425.100
HPA.2525.100
HPA.2625.100
HPA.2725.100
HPA.2825.100
HPA.2925.100
Part Number Description Replacement Element
Consult Parker Filtration for
flow specifications
2µ Absolute pressure filter
3µ Absolute pressure filter
5µ Absolute pressure filter
10µ Absolute pressure filter
25µ Absolute pressure filter
40µ Absolute pressure filter
80µ Absolute pressure filter
125µ Nominal pressure filter
–
–
–
–
HP.1229.10
HP.1229.25
HP.1229.40
HP.1229.125
HPR.1219
HPR.1319
HPR.1419
HPR.1519
HPR.1619
HPR.1719
HPR.1819
HPR.1919
HPA.1219.100
HPA.1319.100
HPA.1419.100
HPA.1519.100
HPA.1619.100
HPA.1719.100
HPA.1819.100
HPA.1919.100
Part Number Description Supersedes Replacement Element
Length 2 G3/8 Port, 5 bar by-pass
Length 1 G1/4 Port No by-pass
Note: Length 1, 10 bar by-pass version available – contact Parker Filtration.
Average filtration Beta Ratio (ISO 16889)
2 10 75 100 200 1000
– – – – – 4.5
– – 3.0 – – –
– – 4.5 5.0 6.0 7.0
– 6.0 8.5 8.0 10.0 12.0
– – – – – –
– – 40.0 – – –
– – 80.0 – – –
– – 125.0 – – –
ASSEMBLY NUMBER
HPA.1219.100
HPA.1319.100
HPA.1419.100
HPA.1519.100
HPA.1619.100
HPA.1719.100
HPA.1819.100
HPA.1919.100
Degree of FiltrationTable A
130
03 HIGH PRESSURE FILTERS 24/10/02 11:13 am Page 130
SH100 SeriesHigh Pressure Filters
Max 100 l/min - 690 bar
Global Filtration Technology
03 HIGH PRESSURE FILTERS 24/10/02 11:13 am Page 131
High Pressure In-Line Stainless Steel FiltersSH100 Series
TYPICAL APPLICATIONS
Hydraulic Start-Up Systems
Flushing Filter
Offshore Cranes
Oil/Gas Industry
Mine Hunters
The Parker Filtration Model SH100 HighPressure In-Line Stainless Steel Filters.
The stainless steel SH100 high-pressure filter is
designed for heavy-duty and critical applications. It
features a flow capacity of 100 l/min at 690 bar working
pressure. A wide range of elements, including high-
strength versions is available. The elements and filter
media used include high-quality materials such as HPFE
glass fibre and stainless steel mesh as well as high
strength mesh cleanable elements and high strength fibre
disposable elements.
TYPICAL APPLICATIONS
132
03 HIGH PRESSURE FILTERS 24/10/02 11:13 am Page 132
High Pressure In-Line Stainless Steel FiltersSH100 Series
SPECIFICATION
Assembly:In-line filter
Operating Pressure:Max 690 bar
Connections:Threads G1/2, G3/4” (ISO228), 1/2”NPT, 3/4”NPT, 3/4” SAE
Seal Material:Nitrile, Neoprene, Fluoroelastomer
Operating Temperature Range:-40°C to 100°C
Degree of Filtration:Determined by multipass test according to ISO 16889
Filtration Media:HPFE glass fibre GDH multi layer glass fibre or StainlessSteel mesh
Flow Fatigue CharacteristicsFilter media is supported so that the optimal fatigue life isachieved
Element Collapse Rating:20 bar (ISO 2941) or 210 bar for high strength version
Bypass Setting:3.5 bar ± 0.2
Differential Pressure Indicator:2.8 barDifferential indicator visualDifferential indicator electrical
Filter Housing:Stainless steel
Filter Element:Element with steel end caps
Options:High strength elements
40(1
.57)
34(1
.34)
22.5
(0.8
8)
Ø100 (3.94)
30 sq.
Ø95(3.74)
PORT TYPE ‘B’ILLUSTRATED
LEN
GT
H 1
– 1
46 (
5.75
)
LEN
GT
H 2
– 2
02 (
7.95
)
13(0.51)
1.5(0.06)
64 (2.52)
16.5
(0.6
5)14
(0.5
5)
93 A
/F (
3.66
)
3 HOLES FOR FIXING BOLTSM8 x 12 DEEP ON FILTERS WITH BSPPORTS AND 5/16” UN x 12 DEEP ONFILTERS WITH SAE OR NPT PORTS
mm(inches)
133
03 HIGH PRESSURE FILTERS 24/10/02 11:13 am Page 133
High Pressure In-Line Stainless Steel FiltersSH100 Series
PRESSURE DROP CURVES
Flow (l/min)
∆p (
bar
)
0
0.5
1
1.5
2
2.5
3
3.5
4
0 10 20 30 40 50 60 70 80
Flow (US GPM)
0 3 5 8 11 13 16 18 21
∆p (
psi
d)
0
7.3
14.5
21.8
36.3
43.5
50.8
58.0
29.0GDH1
GDH3
GDH6 GDH10
GDH20
Flow (l/min)
∆p (
bar
)
0
0.5
1
1.5
2
2.5
3
3.5
0 20 40 60 80 100 120
1/2"BSP
3/4"BSP
∆p (
psi
d)
0
7.3
14.5
21.8
29.0
36.3
43.5
50.8
Flow (US GPM)
0 5 11 16 21 26 31
0
0.5
1
1.5
2
2.5
3
3.5
0 10 20 30 40 50 60 70 80 90 100
GDH1
GDH3
GDH6 GDH10
GDH20
∆p (
bar
)
Flow (l/min)
Flow (US GPM)
0 3 5 8 11 13 16 18 21 24 26
∆p (
psi
d)
0
7.3
14.5
21.8
29.0
36.3
43.5
50.8
Flow (l/min)
∆p (
bar
)
0
0.20.4
0.6
0.81
1.2
1.4
1.61.8
2
0 20 40 60 80 100 120
01
10
Flow (US GPM)
0 5 11 16 21 26 31
∆p (
psi
d)
0
5.8
11.5
17.4
23.2
29.026.1
20.3
14.5
8.7
2.9
Flow (l/min)
∆p (
bar
)
0
0.5
1
1.5
2
2.5
3
0 10 20 30 40 50 60 70 80
FF 10
Flow (US GPM)
0 3 5 8 11 13 16 18 21
∆p (
psi
d)
0
7.3
14.5
21.8
29.0
43.5
36.3
Flow (l/min)
∆p (
bar
)
0
0.5
1
1.5
2
2.5
0 20 40 60 80 100 120
FF
10
Flow (US GPM)
0 5 11 16 21 26 31
∆p (
psi
d)
0
7.3
14.5
21.8
29.0
36.3
Flow (l/min)
∆p (
bar
)
0
0.5
1
1.5
2
2.5
0 20 40 60 80 100 120
01
10
Flow (US GPM)
0 5 11 16 21 26 31
∆p (
psi
d)
0
7.3
14.5
21.8
29.0
36.3
Element HD 100-Series Type 7 L1
Element HD 100-Series Type 7 L2
HD 100-Series Empty Housing
Element HD 100-Series L2 High Strength Type-4
Element HD 100-Series L2 High Strength Type-5
0
0.2
0.4
0.6
0.8
1
1.2
1.4
1.6
1.8
0 10 20 30 40 50 60 70 80
∆p (
bar
)
∆p (
psi
d)
Flow (US GPM)
Flow (l/min)
L1
L2
0 8 18 213 5 11 13 16
0
5.8
8.7
11.5
20.3
23.2
26.1
17.4
14.5
2.9
Element HD 100-Series L1 & L2 Type-9
Element HD 100-Series L1 High Strength Type-4
Element HD 100-Series L1 High Strength Type-5
134
03 HIGH PRESSURE FILTERS 24/10/02 11:13 am Page 134
Table 5ATable 5
Ordering Code175A2L35-NZ121S175A2L35-NZ122S175A2L35-NZ123S175A2L35-DZ221S175A2L35-DZ222S175A2L35-DZ223S
Ordering Code Flow (l/min)505050100100100
Flow (l/min) Micron RatingGDH 06GDH 10GDH 20GDH 06GDH 10GDH 20
Media Rating Ports1/2” NPT1/2” NPT1/2” NPT3/4” NPT3/4” NPT3/4” NPT
Ports IndicatorVisualVisualVisualVisualVisualVisual
Indicator Replacement Elements170Z121A170Z122A170Z123A170Z221A170Z222A170Z223A
Replacement Elements
PREFERRED PRODUCTS TABLE
High Pressure In-Line Stainless Steel FiltersSH100 Series
ORDERING EXAMPLE
Std 2 Std 8 9 10 4
1 2 3 4 5 5A 6 Std 7 8 9 10 Std
1 7 5 A 3 C 35 – B Z 1 22 S
1 7 0 Z 1 22 A
Element TypeHigh strength cleanable Stainless steel*High strength inorganic fibre disposableInorganic fibre disposableCorrosion resistant mesh (cleanable)*
CODE4579
CODE1
HousingModel SH100
Element TypeFilter Type
Table 1 Table 2
VarietyStainless steel
CODE5
Filter Material
Table 3
No bypass port machinedSpool type bypass valveSpool type bypass valveNo bypass valve
Spool type bypass valve
No bypass valve
No indicator / No bypass valveNo indicatorStandard visual indicatorVisual indicator with memory (Latch out)Electrical IDN 43650 28V=/ 250 V ~ No lampsElectrical visual indicator 250 V ~ Green lamps N.C.Electrical visual indicator 250 V ~ Red lamps N.O.Electrical visual indicator 110 V ~ Green lamps N.C.Electrical visual indicator 110 V ~ Red lamps N.O.Electrical visual indicator 28 V = Green lamps N.C.Electrical visual indicator 28 V = Red lamps N.O.
0124
3
5
NNNLTHKCMER
Bypass Indicators
Element typesMineral oil only(Only available on filter type ‘7’)All fluids exc. phos. esters,water glycols and ammonia containing fluidsHFC-FluidsPlease contact Parker Arlon before utilisationAmmonia containing fluidsPlease contact Parker Arlon before utilisationPhosphate estersPlease contact Parker Arlon before utilisation
CODE
L
Z
*T
*F
*S
10 & 20µ only
All ratings
All ratings
All ratings
All ratings
Element Information
Table 8
Seal MaterialNitrile (NBR)Ethylene Propylene (EP)Fluoroelastomer (FPM)
CODEABH
Seal Type
Table 4
Bypass differential pressure settingNo bypass / No indicatorBypass setting 3.5 bar
CODE0035
Bypass Valve
Table 6
PortsISO 228- G1/2 (1/2” BSP)ISO 228- G3/4 (3/4” BSP)1/2” NPT3/4” NPT11/16” SAE (11/16”-12 UN-2B)
CODEBENDJ
Filter Connection
Table 7
Element lengthLength 1Length 2
CODE12
Element Length
Table 9
Element type Filtration Fineness (ßx≥75)5 3µ4 6µ4 or 5 15µ9 40µ7 GDH17 GDH37 GDH67 GDH107 GDH20
CODEFF0110401920212223
Filter Media
Table 10
* Only valid with special cleaning routine.
Note: Filter assemblies ordered from the Part Number Matrix below are on extended lead times.Where possible, please make your selection from the table above.
* Specials on request. Please consult Parker Filtration.
Element
Assembly
Average filtration Beta Ratio (ISO 16889) / particle size µm(c)
2 10 75 100 200 1000
N/A 3.0 4.1 4.4 4.9 6.7
N/A 4.0 6.7 7.0 7.9 10.0
3.1 6.2 9.9 10.4 11.6 14.6
6.7 12.6 17.8 18.5 20.0 22.6
CODE
GDL3/GDH3
GDL6/GDH6
GDL10/GDH10
GDL20/GDH20
Degree of FiltrationTable A
135
03 HIGH PRESSURE FILTERS 24/10/02 11:13 am Page 135