18
0010551959 SPEED POWER HI ON OFF LOW 1 2 3 4 10 9 8 7 6 5 HWR05XC7

Haier Hwr05xc7 Owners Manual

Embed Size (px)

Citation preview

Page 1: Haier Hwr05xc7 Owners Manual

7/23/2019 Haier Hwr05xc7 Owners Manual

http://slidepdf.com/reader/full/haier-hwr05xc7-owners-manual 1/17

0010551959

SPEED

POWER

HI

ON OFF

LOW1

2

3

4

10

9

8

7

65

MINCOOL

MAXCOOL

FAN ONLY

Wait 3Minutes BeforeRestarting

HWR05XC7

Page 2: Haier Hwr05xc7 Owners Manual

7/23/2019 Haier Hwr05xc7 Owners Manual

http://slidepdf.com/reader/full/haier-hwr05xc7-owners-manual 2/17

14-16

17-18

6-7

8-11

8

8-11

12-16

13

13

18-19

20

3

Page 3: Haier Hwr05xc7 Owners Manual

7/23/2019 Haier Hwr05xc7 Owners Manual

http://slidepdf.com/reader/full/haier-hwr05xc7-owners-manual 3/17

 2. MODE Set Switch

2-way

airflow

control

panel

easy

access

filters

SPEED

POWER

HI

ON OFF

LOW1

2

3

4

10

9

8

7

65

MINCOOL

MAXCOOL

FAN ONLY

Wait 3Minutes BeforeRestarting

MODEL: HWF05XC5

6

Page 4: Haier Hwr05xc7 Owners Manual

7/23/2019 Haier Hwr05xc7 Owners Manual

http://slidepdf.com/reader/full/haier-hwr05xc7-owners-manual 4/17

2-way

airflow

control

panel

easy

access

filters

2. f an Speed

TIMEOFF

TIMEON

FAN

POWERON/OFF

COOL

HISPEED

LOWSPEED

MODEL: HWR05XC5

Pressing the Fan Speed button of remote

control between High and Low speed.

7

Page 5: Haier Hwr05xc7 Owners Manual

7/23/2019 Haier Hwr05xc7 Owners Manual

http://slidepdf.com/reader/full/haier-hwr05xc7-owners-manual 5/17

SPEED

POWER

HI

ON OFF

LOW1

2

3

4

10

9

8

7

65

MINCOOL

MAXCOOL

FAN ONLY

Wait 3 Minutes BeforeRestarting

MODEL: HWF05XC5

8

Page 6: Haier Hwr05xc7 Owners Manual

7/23/2019 Haier Hwr05xc7 Owners Manual

http://slidepdf.com/reader/full/haier-hwr05xc7-owners-manual 6/17

Also when you shut off the air conditioner wait f or 3 minutes

bef ore turning it on again.

POWER  Turns air conditioner off.SPEED "LOW" Low speed f an operation with cooling or not.

SPEED "HI" High speed f an operation with cooling or not.

This automatically controls the temperature of indoor air. Turn the kn

so that arrow points to the cooler mark s f or more moderate cooling.

Normal Fan

1. Turn the SPEED mode switch to the "HI" or the "LOW" setting.

2. Set the thermostat control to the temperature mark  "FAN ONLY".

Normal cooling1. Turn the SPEED mode switch to the "HI" or the "LOW" setting.

2. Set the thermostat control to the desire temperature (the mid-point

is a good starting position).

If the room temperature is not satisf actory after a reasonable time, a

the control to a warmer setting, as appropriate.

Maximum cooling

1. Turn the SPEED mode switch to the "HI" setting

2. Set the thermostat control to the MAX COOL temperature mark .Quieter operation

1. Turn the SPEED mode switch to the "LOW" setting.

2. Set the thermostat control as needed.

CAUTION:

1

2

3

9

Page 7: Haier Hwr05xc7 Owners Manual

7/23/2019 Haier Hwr05xc7 Owners Manual

http://slidepdf.com/reader/full/haier-hwr05xc7-owners-manual 7/17

TIME OFF

TIME ON

FAN

POWERON/OFF

COOL

HI SPEED

LOW SPEED

MODEL: HWR05XC5

TEMP/TIME

MODE SPEED TIMER

 ON/OFF1

2

3

4

5   1

Control Panel

10

Page 8: Haier Hwr05xc7 Owners Manual

7/23/2019 Haier Hwr05xc7 Owners Manual

http://slidepdf.com/reader/full/haier-hwr05xc7-owners-manual 8/17

1. ON / OFF

  To turn set ON, press the button. To turn set OFF, press the button again.

2. TIMER

  Press TIMER button, f or each press, TIMER mode will changes as f ollows:

 TIME

R ON TIME

R OFF

  CANCEL

3. FAN

  Pressing the FAN button changes between LOW and HIGH SPEED.

4. MODE

  Every time you press this button, it will change between COOL and FAN.

5. TEMP./ TIME

  Used to set temperature and time.

11

Page 9: Haier Hwr05xc7 Owners Manual

7/23/2019 Haier Hwr05xc7 Owners Manual

http://slidepdf.com/reader/full/haier-hwr05xc7-owners-manual 9/17

12

Page 10: Haier Hwr05xc7 Owners Manual

7/23/2019 Haier Hwr05xc7 Owners Manual

http://slidepdf.com/reader/full/haier-hwr05xc7-owners-manual 10/17

window seal gask et

short screws 13 / 32"

wood screws 31 / 32"

window seal gask et

short screws 13 / 32"

wood screws 31 / 32"

Model: HWR05XC5

Model: HWF05XC5

toprail

13

 ì   CR2025 ì bat teryRemotecontrol

TEMP/TIME

M OD E S PE ED T IM ER

 ON/OFF

top rail

Page 11: Haier Hwr05xc7 Owners Manual

7/23/2019 Haier Hwr05xc7 Owners Manual

http://slidepdf.com/reader/full/haier-hwr05xc7-owners-manual 11/17

HWF05XC5,HWR05XC5

Insert the side curtains into the

top and bottom rails of the air

conditioner. Fasten the curtains

to the unit with  8 short screws

13 / 32".

Install top rail with 3 shortscrews13 / 32".

ASSEMBLE

CURTAINS / TOP RAIL

11   716

17  516

131332

13132

11  58

111316

34  716

201532

14

SPEED

POWER

HI

O N O FF

LOW1

2

3

4

10

9

8

765

MINCOOL

MAXCOOL

FAN ONLY

Wait3MinutesBeforeRestarting

Page 12: Haier Hwr05xc7 Owners Manual

7/23/2019 Haier Hwr05xc7 Owners Manual

http://slidepdf.com/reader/full/haier-hwr05xc7-owners-manual 12/17

1. This unit is designed f or installation in standard double hung windows

with actual opening widths of 21to 35. The upper and lower sash

must open sufficiently to allow a clear vertical opening of 12from the

bottom of the sash to the window stool.

2. If storm window presents interf erence, f asten a 2wide wood strip(not

included) (OUTER SILL) to the inner window sill across the f ull width of 

the sill. The wood strip should be thick  enough to raise the height of 

the window sill so that the unit can be installed without interf erence by

the storm window frame (STORM WINDOW FRAME) or wood strip

(OUTDOORS) to help condensation to drain properly to the outside.

3. Install a second wood strip (approximately 6long by 3 / 2wide and

same thickness as first strip) in the center of the outer sill flush against

the back  off the inner sill. This will raise basepan angle  .

4. If the distance between STORM WINDOW FRAME and WOOD STRIP

MOUNTED ON TOP OF INNER SILL is more than 1, two of woodstrip are not necessary.

INNER

SILL

OUTER

SILL

I

N

D

O

O

R

S

O

U

T

D

O

O

R

S

WOOD STRIP

MOUNTED ON

TOP OF INNER SILL

WOOD STRIP

FOR BASEPANANGLE

STORM

WINDOW FRAME

1  MAX.

3 / 4CLEARANCE

I

N

D

O

O

R

S

O

U

T

D

O

O

R

S

INNER

SILL

OUTER

SILL

LOCATING UNIT IN

WINDOW

Open the window and mark  center line on the

center of the inner sill.

CENTER LINE

INNER SILL

INDOOR SIDE

ATTACH BASEPAN

ANGLE

CENTER LINE

SHORT SCREW13 / 32"INNER SILL

OUTER SILL

SHORT SIDE

BASEPAN ANGLE

7,5

7,5

OUTSIDE

INSIDE

Install the basepan angle behind the inner window sill, with

the short side of basepan angle as shown. Use the 2 short

screws13 / 32" provided.

The basepan angle helps to hold unit securely in place.

Be sure to place basepan angle edge flush against back 

of inner sill.

2

15

Page 13: Haier Hwr05xc7 Owners Manual

7/23/2019 Haier Hwr05xc7 Owners Manual

http://slidepdf.com/reader/full/haier-hwr05xc7-owners-manual 13/17

INSTALL THE AIR CONDITIONER

IN THE WINDOW

Caref ully lift the air conditioner and slide it into the open

window. Mak e sure the bottom guide of the air condit ioner

drops into the notches of the basepan angle.While steadying the air conditioner ,caref ully bring the

window sash down behind the upper guide of the air

conditioner.

INSTALL THE SEAL GASKET

AND SASH LOCK

Extend the side curtains to fill the

window opening using 4  wood screws

31 / 32" to secure them.

Cut the seal gask et to the window

width. Stuff the sash seal between the

glass and the window to prevent air

and insects from getting into the room.

Fasten the basepan angle, using a

short screw13 / 32".

WINDOW SEAL GASKETBASEPAN ANGLE

SHORT SCREW13 / 32"

WOOD SCREW31 / 32"

WINDOW FRAME

UPPER GUIDE

BOTTOM GUIDE

BASEPAN ANGLE

ABOUT 1 / 4

16

Page 14: Haier Hwr05xc7 Owners Manual

7/23/2019 Haier Hwr05xc7 Owners Manual

http://slidepdf.com/reader/full/haier-hwr05xc7-owners-manual 14/17

Always use a soft cloth dampened with water or mild soap

and water solution to wipe the front of the cabinet.

To clean the front panels or the cabinet DO NOT use harsh

chemicals, abrasives, ammonia, chlorine, bleach, concentrated

detergents, solvents or metal scouring pads.

DO NOT use your air conditioner without the air filter in place.

Always unplug your air conditioner bef ore cleaning.

The air filter behind the inlet grille should be check ed and cleaned at

every 2 week s (or as necessary) to maintain optimal perf ormance of the 

conditioner.

How to remove the air filter

1. The grille may be opened from the top f or easy maintenance after ins

2. Open the inlet grille by pulling off the exposed door on the top of

on the installation).

3. Pull the tab slightly to release the filter. Pull the filter in the s

the opening.

4. Clean the filter with warm, soapy water. The water should be below 405. Rinse off and gently shak e off excess water from the filter. Let it d

replacing it.

17

Page 15: Haier Hwr05xc7 Owners Manual

7/23/2019 Haier Hwr05xc7 Owners Manual

http://slidepdf.com/reader/full/haier-hwr05xc7-owners-manual 15/17

18

Page 16: Haier Hwr05xc7 Owners Manual

7/23/2019 Haier Hwr05xc7 Owners Manual

http://slidepdf.com/reader/full/haier-hwr05xc7-owners-manual 16/17

(see page 8)

(see page 16)

19

Page 17: Haier Hwr05xc7 Owners Manual

7/23/2019 Haier Hwr05xc7 Owners Manual

http://slidepdf.com/reader/full/haier-hwr05xc7-owners-manual 17/17