Key Features• Compliant with Version 1.4a of the HDMICompliance TestSpecification
• Dedicated signal pull-uptermination provided by TF-HDMI-3.3V enables full bandwidth testing using cables
• Simple and easy-to-useautomated testing
• Powerful and flexible analysistools offer unmatched insight for diagnosing and solvingelusive problems
• Support for all clock rates described in Version 1.4a of the specification
• Connection diagrams help tomake sure that you get the right setup on the first try
• QualiPHY report generationcreates comprehensive reports with all pertinent test information
QPHY-HDMI provides a highlyautomated and easy-to-use solution for HDMI transmittertesting in accordance withVersion 1.4a of the HDMICompliance Test Specification.
HDMI Test SolutionsQPHY-HDMI
The QPHY-HDMI software package
for the WaveMaster/SDA/DDA
8 Zi/Zi-A Series of oscilloscopes
provides a concise set of validation/
verification and debug tools written in
accordance with version 1.4a of the
High Definition Multimedia Interface
(HDMI) electrical test specification.
HDMI test modes cover amplitude,
timing and jitter parameters. In addi-
tion to standard eye pattern and jitter
tests for HDMI, the SDA real-time
test equipment platform provides
a complete set of amplitude and
jitter measurements, as defined
in the HDMI specification. This
combination of measurements
makes QPHY-HDMI a cost-effective,
compelling HDMI solution.
Once a problem is detected, all
of the power SDA tools are at your
disposal to help find the root cause.
2
This image is showing a measurement of VL level (Test 7–2). C1is triggered at the end of an H-L-L-L bit sequence. F2 is a zoom onthe last L-L bits. P3 is the most frequent level of those L-L bits.
This image is a measure of Clock Rise Time (Test 7–4). F4 is theClock. F1 is the histogram of F4 vertical levels. The two peaks correspond to base and top, they are used to compute the 20% and 80% levels. Z1 is a zoom of F4 showing the computed levels. P6 is a measure of F4 rise time at these levels. F2 is thehistogram of P6 and P7 is the mode of F2, final measure asspecified by the standard.
This image is a measure of the Eye Diagram (Test 7–10). The eye is validated against the mask as defined by the standard.
QPHY-HDMI Makes Compliance Testing Easy
Typically, compliance testing is a very difficult task.
The user must make the necessary connections between
the oscilloscope and the device under test, manually
configure the oscilloscope for the appropriate measure-
ment, perform the test procedure as specified by the
test specification, record the results and finally compare
the results to the appropriate limit in the compliance
specification. QPHY-HDMI does all of these steps
for you automatically after indication of the correct
connection to use.
Comprehensive and Easy-to-read Test Reports
Measurement results often need to be summarized and
tabulated to quickly verify specifications. This information,
together with instrument and signal acquisition/test
condition setups, results in a fully documented record.
QPHY-HDMI streamlines this process by incorporating an
automatic HTML report generation engine. The created
test reports contain tabulated numerical values for each
individual test result, including PASS/FAIL and specifica-
tion limit columns. Reports can also be saved as PDF,
HTML or XML.
Advanced Debug Capability
If a compliance failure is found, LeCroy’s SDA II serial
data analysis package is available to help find the root
cause quickly and easily. SDA II has the ability to perform
Eye and Jitter measurements simultaneously and is fully
integrated into the oscilloscope application software.
In addition, SDA II provides insight into the measured
Eye and Jitter parameters making is easier to identify
the sources of problems.
3
Supported Tests from Version 1.4a of the High
Definition Multimedia Interface Compliance Test
Specification
• 7-2 TMDS — VL
• 7-4 TMDS — TRise, TFall
• 7-5 TMDS — Over/Undershoot (Not Mandatory)
• 7-6 TMDS — Inter-Pair Skew
• 7-7 TMDS — Intra-Pair Skew
• 7-8 TMDS — Clock Duty Cycle
• 7-9 TMDS — Clock Jitter
• 7-10 TMDA — Data Eye Diagram
QualiPHY has many predefined configurations that allow
users to run complete compliance test. In addition, users
can create their own custom test groups and limit sets.
When the tests are complete, QualiPHY will generate a
full test report in PDF, HTML, or XML formats (including
eye diagrams and other screenshots).
HMDI Test Results Report.
QualiPHY has many preset compliance configurations but alsoenables users to create their own configuration and limit sets.
QPHY-HDMI-DS-21July11PDF
TF -HDMI-3.3V adapter provides the necessary 3.3 V pull-uptermination for HDMI testing.
TF-HDMI-3.3V
The TF-HDMI-3.3V adapter provides the necessary 3.3 V
pull-up termination for HDMI testing. The TF-HDMI-3.3V
provides both a signal path through to the oscilloscope
with a 3.3 V pull-up termination as well as an input that
is directly terminated to 3.3 V. This is required for
terminating the data lines that are not currently under
test. The TF-HDMI-3.3V-QUADPAK provides four adapters
and 8 SMA-SMA cables to allow for the testing of all
HDMI signals (Clock, D0, D1 and D2).
Product Description Product Code
QualiPHY Enabled HDMI Software Option *QPHY-HDMIHDMI Pull-up Terminator –- for use TF-HDMI-3.3Vwith the WilderTech HDMI-TPA-P Test Adapter SetHDMI Pull-up Terminator Quad Pack †TF-HDMI-3.3V-QUADPAK– for use with the WilderTech HDMI-TPA-PTest Adapter Set
* TF-HDMI-3.3V-QUADPAK required.
† LeCroy recommends using the WilderTech HDMI-TPA-P (plug test adapter) used in conjunction with HDMI-TPA-E (EDID board with EEPROM).
WaveMaster 8 Zi-A/Zi Series Oscilloscopes4, 6 GHz, 40 GS/s, 4 Ch, 20 Mpts/Ch *‡WaveMaster 804Zi-AWaveMaster with 15.3" WXGA Color Display. 806Zi-A50 Ω and1 MΩ Input6, 13, 16, 20 GHz, 40 GS/s, 4 Ch, 20 Mpts/Ch ‡WaveMaster 808Zi-AWaveMaster with 15.3" WXGA Color Display. 813Zi-A, 816Zi-A, 820Zi-A50 Ω and 1 MΩ Input25, 30 GHz, 80 GS/s, 2 Ch, 40 Mpts/Ch ‡WaveMaster 825Zi-A,WaveMaster with 15.3" WXGA Color Display. 830Zi-A50 Ω and 1 MΩ Input (20 GHz, 40 GS/s, 4 Ch, 20 Mpts/Ch) 45 GHz, 120 GS/s, 1 Ch, 60 Mpts/Ch ‡WaveMaster 845Zi-AWaveMaster with 15.3" WXGA Color Display. 50 Ω and 1 MΩ Input (30 GHz, 80 GS/s, 2 Ch, 40 Mpts/Ch; 20 GHz, 40 GS/s, 4 Ch, 20 Mpts/Ch)
SDA 8 Zi-A/Zi Series Serial Data Analyzers4, 6 GHz, 40 GS/s, 4 Ch, 32 Mpts/Ch Serial Data Analyzer *SDA 804Zi-Awith 15.3" WXGA Color Display. 50 Ω and 1 MΩ Input 806Zi-A8, 13, 16, 20 GHz, 40 GS/s, 4 Ch, 32 Mpts/Ch SDA 808Zi-A, 813Zi-ASerial Data Analyzer with 15.3" WXGA 816Zi-A, 820Zi-AColor Display. 50 Ω and 1 MΩ Input25, 30 GHz, 80 GS/s, 2 Ch, 64 Mpts/Ch SDA 825Zi-A Serial Data Analyzer with 15.3" WXGA SDA 830Zi-AColor Display. 50 Ω and 1 MΩ Input (20 GHz, 40 GS/s, 4 Ch, 32 Mpts/Ch)45 GHz, 120 GS/s, 1 Ch, 96 Mpts/Ch SDA 845Zi-ASerial Data Analyzer with 15.3" WXGA Color Display. 50 Ω and 1 MΩ Input (30 GHz, 80 GS/s, 2 Ch, 64 Mpts/Ch; 20 GHz, 40 GS/s, 4 Ch, 32 Mpts/Ch)
DDA 8 Zi-A/Zi Series Oscilloscopes20 GHz, 40 GS/s, 4 Ch, 32 Mpts/Ch DDA with DDA 820Zi-A15.3" WXGA Color Display. 50 Ω and 1 MΩ Input30 GHz, 80 GS/s, 2 Ch, 64 Mpts/Ch DDA with DDA 830Zi-A15.3" WXGA Color Display. 50 Ω and 1 MΩ Input (16 GHz, 40 GS/s, 4 Ch, 20 Mpts/Ch)
WavePro 7 Zi-A/Zi Series Oscilloscopes4, 6 GHz, 20 GS/s, 4 Ch, 20 Mpts/Ch *‡WavePro 740Zi-A, 760Zi-A(40 GS/s and 40 Mpts/Ch in interleaved mode)with 50 Ω and 1 MΩ Input
SDA 7 Zi-A/Zi Series Serial Data Analyzers4, 6 GHz, 20 GS/s, 4 Ch, 20 Mpts/Ch *SDA 740Zi-A, 760Zi-A(40 GS/s and 40 Mpts/Ch in interleaved mode)with 50 Ω and 1 MΩ Input
DDA 7 Zi-A/Zi Series Oscilloscope6 GHz, 20 GS/s, 4 Ch, 20 Mpts/Ch *DDA 760Zi-A(40 GS/s and 40 Mpts/Ch in interleaved mode)with 50 Ω and 1 MΩ Input
SDA Series Serial Data Analyzers4 Ch; 4 GHz Serial Data Analyzer; 20 GS/s; 20 Mpts/Ch *SDA 40204 Ch; 6 GHz Serial Data Analyzer; 20 GS/s; 20 Mpts/Ch *SDA 60204 Ch; 9 GHz Serial Data Analyzer; 9 GHz, 40 GS/s *†SDA 900040 Mpts/Ch on 2 Ch; 6 GHz, 20 GS/s 20 Mpts/Ch on 4 Ch4 Ch; 11/6 GHz Serial Data Analyzer; 11 GHz, 40 GS/s *†SDA 1100040 Mpts on 2 Ch; 6 GHz, 20 GS/s 20 Mpts on 4 Ch4 Ch; 13/6 GHz Serial Data Analyzer; 13 GHz, 40 GS/s *†SDA 1300040 Mpts on 2 Ch; 6 GHz, 20 GS/s 20 Mpts on 4 Ch4 Ch; 18 GHz Serial Data Analyzer; 18 GHz, 60 GS/s *†SDA 1800060 Mpts on 1 Ch, 6 GHz, 20 GS/s 20 Mpts/Ch on 4 Ch
* The HDMI test specification requires 8 GHz bandwidth for testing clock rates above148.5 MHz. For testing with clock rates below 148.4 MHz, 4 GHz is required.
† The HDMI test specification requires to use the oscilloscope in 4 Ch mode.
‡ SDA II Serial Data Analysis Option required.
Customer ServiceLeCroy oscilloscopes and probes are designed, built, and tested to ensure high reliability. In the unlikely event you experience difficulties, our digital oscilloscopesare fully warranted for three years and our probes are warranted for one year.
This warranty includes: • No charge for return shipping
• Long-term 7-year support • Upgrade to latest software at no charge