A special air condit ioning system designedfor smal l-sized bui ldings

PCVAU0737F

HEAT PUMPHeat Pump 50 Hz

Page 2: HEAT PUMP - Jaicrest Air Conditioningassets.jaicrest.com.au/downloads/brochures/daikin/Daikin VRVIII-S... · Ceiling Mounted Cassette (Round Flow) Type Model Name Capacity Range Capacity

SSThe 5S+1E concepts of

Extending the core “5S” concept—Space saving, Sufficient capacity, Slim design, Sound-reduced operation and Single phase power supply—Daikin’s VRVIII-S offers added value with the “1E” concept—Easy installation. With all these features and more, we proudly present the ideal air conditioning system designed for small-sized buildings.

The ideal air conditioning

small office

Space saving

Sufficient capacity

Slim design

Sound-reduced operation

Single phase power supply

Easy installation E1Econcept

5Sconcept

1

Page 3: HEAT PUMP - Jaicrest Air Conditioningassets.jaicrest.com.au/downloads/brochures/daikin/Daikin VRVIII-S... · Ceiling Mounted Cassette (Round Flow) Type Model Name Capacity Range Capacity

system for

s and shops

2

765 mm

The VRVIII-S is highly space saving, featuring slim and compact outdoor units. It is suitable for small offices and shops with capacities of 4, 5 and 6 class (11.2, 14 and 15.5 kW).

Slim, compact and sufficient capacity

Approx. 40%reduction

Approx. 50%reduction

635 mm 900 mm

320 mm

Volume

VRVIII(5 class (14 kW))

Footprint

(4, 5, 6 class (11.2, 14, 15.5 kW))

VRVIII(5 class (14 kW)) (4, 5, 6 class (11.2, 14, 15.5 kW))

The compact, trunk-shaped outdoor unit can easily be installed on a balcony, realising complete system installation within each floor. This enables more useful utilisation of the space on the building rooftop.

Outdoor unit can be installed on a balcony

ContentContents

Introduction..............page 1

Main features...........page 3

Control systems.....page 9

Indoor unit lineup.....page 15

Specifications.................page 27

Indoor units............page 27Outdoor units........page 34

Option list..........................page 35

Indoor units..............page 35Outdoor units...........page 37Control systems......page 37

Page 4: HEAT PUMP - Jaicrest Air Conditioningassets.jaicrest.com.au/downloads/brochures/daikin/Daikin VRVIII-S... · Ceiling Mounted Cassette (Round Flow) Type Model Name Capacity Range Capacity

MAIN FEATURES

3

Wide range of choicesTo suit the variety of rooms found in small offices and shops, the VRVIII-S system offers a wide range of indoor and outdoor units.VRVIII-S indoor and outdoor units are almost as easy to install as residential air conditioning systems, making them ideal for small offices and shops.

Outdoor unit can be selected from three models to provide the power that suits

your needs. The trunk-shaped outdoor unit can be neatly installed outside the office.

3 modelsOutdoor units

Model Name

Capacity Range

Capacity Index

RXYMQ4PV4A RXYMQ5PV4A RXYMQ6PV4A

4 class (11.2 kW) 5 class (14 kW) 6 class (15.5 kW)

100 125 140

Outdoor unit lineup

Page 5: HEAT PUMP - Jaicrest Air Conditioningassets.jaicrest.com.au/downloads/brochures/daikin/Daikin VRVIII-S... · Ceiling Mounted Cassette (Round Flow) Type Model Name Capacity Range Capacity

Indoor unit lineup 14 types 78 models

A wide range of indoor units includes 78 models in 14 types. The indoor units can be selected to match rooms and preferences.

14 types 78 modelsIndoor units

4

New

Ceiling MountedCassette (Round Flow)

Type Model Name Capacity Range

Capacity Index 20 40 62.5 80 100 1405031.2525

2.2 kW 4.5 kW 7.1 kW 9 kW 11.2 kW 16 kW

125

14 kW

145

16.2 kW

140 145

5.6 kW3.6 kW2.8 kW

Ceiling Mounted Cassette(Compact Multi Flow)

FXFQ-PVE

FXZQ-MVE

Slim CeilingMounted Duct

Ceiling MountedDuct

Ceiling Suspended

Wall Mounted

Floor Standing

ConcealedFloor Standing

Ceiling Mounted Cassette(Double Flow)

FXDQ-NBVE(900/1,100 mm width type)

FXMQ-PVE

FXHQ-MAVE

FXAQ-PVE

FXLQ-MAVE

FXNQ-MAVE

FXCQ-MVE

Ceiling MountedBuilt-in FXSYQ-MVE

FXDQ-PBVE(700 mm width type)

R-410A VRV system indoor units are not compatible with the R-22 VRV system.Note:

Ceiling MountedCassette Corner FXKQ-MAVE

Ceiling Concealed (Duct) FXDYQ-MAV1

BEV units are necessary for Connection unit series indoor units. Refer to the Engineering Data Book for details.Note:

Ceiling Suspended Cassette

Type Model Name

4.5 kW2.2 kW 3.6 kW2.8 kW

FXUQ-MAV1

20 4031.2525BEVQ125MAVE

14 kW

BEVQ100MAVEBEVQ71MAVE

5.6 kW 11.2 kW8 kW50 12510071

Capacity Range4020 3225 12550 10071

Connection UnitCapacity Index

20 40 63 80 100 125503225

Connection unit series indoor units

New New New New New New

Page 6: HEAT PUMP - Jaicrest Air Conditioningassets.jaicrest.com.au/downloads/brochures/daikin/Daikin VRVIII-S... · Ceiling Mounted Cassette (Round Flow) Type Model Name Capacity Range Capacity

Energy efficiency and quiet operationOutdoor units use Daikin’s unique scroll compressor for energy efficiency and quiet operation.

MAIN FEATURES

High COP during both cooling and heating operations

Quiet operation provides luxurious comfortQuietness is yet another important feature of Daikin’s VRVIII-S system. To reduce noise and realise comfortable operation, latest technologies and features are applied to the outdoor units.

One of the top features of the VRVIII-S is its energy efficiency. It achieves high COP during cooling and heating operations by utilising Daikin’s unique scroll compressor.

Above values are based on the following nominal conditions:• 2 built-in units are connected (4 class (11.2 kW): FXSYQ50M x 2; 5 class

(14 kW): FXSYQ63M x 2; and 6 class (15.5 kW): FXSYQ63M + FXSYQ80M.)• Cooling: Indoor temp. of 27°CDB, 19.0°CWB, and outdoor temp. of 35.0°CDB.• Heating: Indoor temp. of 20°CDB, and outdoor temp. of 7°CDB, 6°CWB.

VRVII-SPrevious modelRXYMQ-MV4A

VRVII-SPrevious modelRXYMQ-MV4A

Lower operation sound is achieved!

Cooling

Heating

2.94

3.62

2.81

3.45

3.733.58

3.032.82

Cooling 505153

4 class (11.2 kW)

5 class (14 kW)

6 class (15.5 kW)

5 class (14 kW)

3.153.074 class (11.2 kW)

6 class (15.5 kW)

5 class (14 kW)

3.373.274 class (11.2 kW)

6 class (15.5 kW)

Heating 525355

53

54

56

51

52

54

4 class (11.2 kW)

5 class (14 kW)

6 class (15.5 kW)

5

Nighttime quiet operation function

Set on the outdoor PCB. Time of maximum temperature is memorised. The low operating mode will initiate 8 hours*1 after the peak temperature in the daytime, and normal operation will resume 10 hours*2 after that. The operation sound level for the night mode can be selected from 47 dB(A) (Step 1), 44 dB(A) (Step 2) and 41 dB(A) (Step 3).

Automatic modeMode 1.

Automatic modeMode 1.

Starting time and ending time can be input. (An external control adaptor for outdoor unit, DTA104A53/61/62, and a locally obtained timer are necessary.)

Manual modeMode 2.

Combinations of modes 1 and 2 can be used depending on your needs.

Combined modeMode 3.

*1. Initial setting. Can be selected from 6, 8 and 10 hours.*2. Initial setting. Can be selected from 8, 9 and 10 hours.

Note: • This function is available in setting at site.

• The relationship of outdoor temperature (load) and time shown in the graph is just an example.

Peak in outdoor temperature

Capa

city

%

8 hrs 10 hrs

Oper

atio

n so

und

dB(A

)

47

8:00 12:00 16:00 20:00 0:00 4:00 8:00

50

100

500

Load

%

Night mode endsNight mode starts Night mode endsNight mode starts

Night Mode

44

41

(Initial setting)(Initial setting)

Step 1 max. - 3 dB(A)( 4 class/11.2 kW)

Step 2 max. - 6 dB(A)( 4 class/11.2 kW)

Step 3 max. - 9 dB(A)( 4 class/11.2 kW)

Step 1: 47 dB(A)

Step 2: 44 dB(A)

Step 3: 41 dB(A)

Operation sound level selectablefrom 3 steps for the night mode

The capacity reduction rate differs depending on the operation sound level step selected.

-1dB(A)

-1dB(A)

-1dB(A)

-1dB(A)

-1dB(A)

-1dB(A)

1 dB(A) reduced in each model!

High COPachievedin all ranges!

Page 7: HEAT PUMP - Jaicrest Air Conditioningassets.jaicrest.com.au/downloads/brochures/daikin/Daikin VRVIII-S... · Ceiling Mounted Cassette (Round Flow) Type Model Name Capacity Range Capacity

6

These two features work to reduce sound. Guides are added to the bell mouth intake to reduce turbulence in the airflow generated by fan suction. The Aero Spiral Fan features fan blades with the bent blade edges, further reducing turbulence.

Smooth Air Inlet Bell Mouth and Aero Spiral Fan

A collection of cutting-edge technologies results in efficient and quiet operation.The high efficiency compressor to achieve a higher COP

2

1

Note: Data are based on studies conducted under controlled conditions at a Daikin laboratory.

Note: Data are based on studies conducted under controlled conditions at a Daikin laboratory using Daikin products.

*1 A neodymium magnet is approximately 10 times stronger than a standard ferrite magnet.

*2 The torque created by the change in power between the iron and magnet parts.

DC fan motorEfficiency improved in all areas compared to conventional AC motors, especially at low speeds.

Sine wave DC inverter >> Smooth sine wave DC inverter Use of an optimised sine wave smoothes motor rotation, further improving operating efficiency.

Daikin DC inverter models are equipped with the Reluctance DC motor for compressor. The Reluctance DC motor uses 2 different types of torque, neodymium magnet*1 and reluctance torque*2. This motor can reduce energy used because it generates more power with a smaller electric power than an AC or conventional DC motor.

Compressor equipped with Reluctance DC motor

3DC motor efficiency

(comparison with AC motor)

200 300 400 500 600 700 800 900 1000

0

20

40

80

60

100

Eff

icie

ncy

(%

)

Motor speed (rpm)

AC motorAC motorAC motorAC motorAC motorApprox.

40%increase

Approx.

20%increase

DC motorDC motorDC motorDC motorDC motor

Reluctance DC motor

Conventional DC motor

AC motor

Rotational speed (rps)

Mo

tor

effi

cien

cy (

%)

DC fan motor structure

ReluctanceDC motor

3

1

2

Escaping eddies are sucked in by the bent blade edges, reducing overall turbulence.

With the bent blade edge

Without the bent blade edge

90

80

70

60

500 30 60 90 120

More than 20%More than 20%

Small loadLow capacity

Large loadHigh capacity

RXYMQ4PV4ARXYMQ5PV4ARXYMQ6PV4A

Page 8: HEAT PUMP - Jaicrest Air Conditioningassets.jaicrest.com.au/downloads/brochures/daikin/Daikin VRVIII-S... · Ceiling Mounted Cassette (Round Flow) Type Model Name Capacity Range Capacity

Design flexibilityVRVIII-S systems offer broad design flexibility with long refrigerant piping lengths and multiple indoor unit combinations, which provides generous freedom for office and shop design both inside and out.

MAIN FEATURES

For a 6 class (15.5 kW) installation

Multiple indoor unit combinations are possible. * As many as 9 indoor units can be connected to a 6 class (15.5 kW) unit, making the VRVIII-S a versatile system.* Total capacity index of connectable indoor units must be 50 - 130 % of the capacity index of the outdoor unit.

Up to 9 indoor units can be connected to a single outdoor unit

The VRVIII-S provides the long piping length possibility of 150 m, with a total piping length of 300 m. If the outdoor unit is installed above indoor units the level difference can be up to a maximum of 50 m. These generous allowances facilitate an extensive variety of system designs.

Long piping design possible

Actual piping length

Max. 150 m

Total piping length

Max. 300 m

1 2 3 4

5 6 7 8 9

units

Max.

9 >> Max. 8 indoor units for a 5 class (14 kW) installation

>> Max. 6 indoor units for a 4 class (11.2 kW) installation

*1. 40 m when the outdoor unit is installed below indoor units.*2. Maximum piping length between the indoor unit and the first branch is 40 m.

Note:

The operation range of the VRVIII-S system works to reduce limitations on installation locations. The operation temperature range for heating goes all the way down to -20°C, while cooling can be performed with outdoor temperatures as high as 46°C. Both these achievements are due to the adoption of a high-pressure dome-type compressor.

Certified operation temperature rangeWide operation temperature range

7

-10

0

10

20

30

40

50

-20

-10

0

10

20 15.5°CWB

Heating

46°CDB

Cooling

-5°CDB-20°CWBO

utdo

or te

mpe

ratu

re (°

CD

B)

Out

door

tem

pera

ture

(°C

WB

)

Max. 50 m*1*2

Max. 15 m

Leveldifference

Level differencebetween indoorunits

Page 9: HEAT PUMP - Jaicrest Air Conditioningassets.jaicrest.com.au/downloads/brochures/daikin/Daikin VRVIII-S... · Ceiling Mounted Cassette (Round Flow) Type Model Name Capacity Range Capacity

Easy installationA variety of functions are provided that make installation easier, such as simple wiring and piping and automatic test operation.

A printed circuit board has been adopted that is much easier to see and wire during installation.

Easy wiring

Simply press the test operation button after refrigerant charging is completed, and the unit performs an automatic system check, including wiring, shutoff valves, and sensors. The results are returned automatically after the check finishes.

Automatic test operation

Previous modelVRVII-S

8

Unique piping and wiring systems make it possible to install a VRVIII-S system quickly and easily.

Simple wiring and piping connection

Daikin’s advanced REFNET piping system makes installation easy. Only two main refrigerant lines are required in any one system. REFNET greatly reduces the imbalances in refrigerant flow between units, while using small-diameter piping.

>> REFNET piping system

A super wiring system is used to enable shared use of the wiring between indoor and outdoor units and the central control wiring, with a relatively simple wiring operation. The DIII-NET communication system is employed to enable the use of advanced control systems.

>> Super wiring system

Outdoor unit

Centralremote

controllerIndoor unit

Page 10: HEAT PUMP - Jaicrest Air Conditioningassets.jaicrest.com.au/downloads/brochures/daikin/Daikin VRVIII-S... · Ceiling Mounted Cassette (Round Flow) Type Model Name Capacity Range Capacity

Control systemsThe VRVIII-S system uses the same DIII-NET communication system as the VRV, enabling the use of advanced control systems.

CONTROL SYSTEMS

Individual control systems

Digital display lets you set temperature in 1°C units.Lets you individually programme by timer the respective times for operation start and stop within a maximum of 72 hours.Equipped with a thermostat sensor in the remote controller that makes possible more comfortable room temperature control.Enables you to select cool/heat/fan operation mode with the indoor remote controller of your choice without using the cool/heat selector. (dependant on system)Equipped with self-diagnosis function that constantly monitors the system for malfunctions. Should a problem occur, the system alerts you of the problem through an alphanumeric code.The rubber switch and the oil-resisting resin casing have been adopted for durability.

* When the auto-swing function is not available, the message, THIS FUNCTION IS NOT AVAILABLE is displayed when the air direction adjustment button is pressed.

Wired remote controller (Option)

BRC1C62

Outdoor unit

Indoor unit

Forced OFF input

Remote controllerRemote controller

Remote controllerRemote controller

Remote controllerRemote controller

Remote controller

Remote controller

Heat Reclaim Ventilator

The indoor unit can be connected by the two remote controller, for example one in the room and the other one in the control room, which can control the operation of indoor unit freely.(The last command has a priority.) Of course, the group control by two remote controllers is also possible.

Control by two remote controllers

The system can be expanded to add several controllers, such as BMS, Forced OFF input and etc.

Expansion of system control

In all the series of VRV, Cool/Heat changeover in the same refrigerant circuit can be changed by the master remote controller of an indoor unit.

Control of Cool/Heat changeover

One remote controller can control the operation of max.16 indoor units at the same time.

Group control

Equipment related to the central control

1 2 3

The wiring of remote controller can be extended to max.500 m and it is possible to install the remote controllers for the different indoor units in one place.

Remote control

The operation of Heat Reclaim Ventilator can be controlled by the remote controller of the indoor unit. Of course, the remote controller can display the time to clean the filter.

Control for the combined operation

4

4

3

2

1

Refer to page 7 for the total number of indoor units that can be connected to the outdoor unit.

The wired remote controller supports a wide range of control functions

9

Wired remote controller with weekly schedule timer (Option)

BRC1D61

24-hour clock function (1-hour backup for power failures)

Includes ventilation mode and airflow rate switching, the main functions of Heat Reclaim Ventilator series.

Programming function for each day of week.

Scheduling possible of start/stop and temperature limit (5 settings/day)

Programming can be enabled or disabled.

Copy function for programmed schedules.

Adds advanced functions to those of the above wired remote controller.

Notes: 1. Standard remote controllers (BRC1C62) not required. 2. If the BRC1D61 is connected to the centralised remote controllers (DCS303A51, DCS302CA61,DCS301BA61, DST301BA61), the schedule function is not available.

Page 11: HEAT PUMP - Jaicrest Air Conditioningassets.jaicrest.com.au/downloads/brochures/daikin/Daikin VRVIII-S... · Ceiling Mounted Cassette (Round Flow) Type Model Name Capacity Range Capacity

The same operation modes and settings as with wired remote controllers (BRC1C62 only) are possible.

A compact signal receiver unit (separate type) to be mounted into a wall or ceiling is included.

Signal receiver unit(Separate type)

Wireless remote controller

The concealed type remote controller smartly fits into a night table or console panel in a hotel room.

Wireless remote controller (Option)

Simplified remote controller (Option)

Wide variation of remote controllers for indoor units

Wired remote controller(BRC1C62)

Wired remote controller with weekly schedule timer

(BRC1D61)

Wireless remote controller*(Installed type signal receiver unit)

Wireless remote controller*(Separate type signal receiver unit)

Simplified remote controller(Exposed type)

(BRC2C51)

Simplified remote controller(Concealed type: for Hotel use)

(BRC3A61)

FXFQ FXZQ FXKQ FXDYQ FXMQ FXHQ FXUQFXAQ FXL(N)QFXDQ

*Wireless remote controller and signal receiver unit are sold as a set. * Refer to page 37 for the name of each model.

* Refer to page 37 for the name of each model.

• A signal receiver unit (installed type) for a Ceiling Mounted Cassette (Round Flow, Compact Multi Flow, Double Flow) type, Ceiling Suspended type and Wall Mounted type is mounted into the indoor unit.

Signal receiver unit can be installed on the panel ex. Ceiling Mounted Cassette (Round Flow) type

The remote controller has centralised its frequently used operation selectors and switches (on/off, operation mode, temperature setting and airflow volume), making itself suitable for use in hotel rooms or conference rooms.

The exposed type remote controller is fitted with a thermostat sensor.

Concealed type(For hotel use)

(BRC3A61)

Exposed type(BRC2C51)

FXCQ FXSYQ

10

Signal receiver unit(Installed type)

Page 12: HEAT PUMP - Jaicrest Air Conditioningassets.jaicrest.com.au/downloads/brochures/daikin/Daikin VRVIII-S... · Ceiling Mounted Cassette (Round Flow) Type Model Name Capacity Range Capacity

CONTROL SYSTEMS

Up to 64 groups of indoor units (128 units) can be centrally controlled.

Optional controllers for centralised control can be combined and optimised in

accordance with building scale and purpose.

System integration with various air-conditioning peripheral equipment such as

Heat Reclaim Ventilator is easy.

Wiring can be run up to a total length of 2 km, and adapts easily to large-scale

system expansion.

Centralised control systems

For more details, please refer to the Engineering Data Book.

1. Refer to page 7 for the total number of indoor units that can be connected to the outdoor unit.

• Certain indoor units limit the functions of some control systems.

11

Central control adaptor kit (DTA107A55)

Wiring adaptorfor other air-conditioners (DTA103A51)

Central remote controller(DCS302CA61)

Up to 2 units connectable

Unified on/off controller(DCS301BA61)

Connection of up to 8 unitspossible

Schedule timer (DST301BA61)1 unit connection possible ; 8 weekly schedule control patterns possible

Forced shut-down input

Independent and centralised control of Heat Reclaim Ventilator is possible.

Unification adaptor for computerised control (DCS302A52)

Interlink Building Management System (host computer monitor panel) also possible

6 cores 7 cores max.

Address setting of central control can be performed from the remote controller.

Group control of up to 16 units is possible (group control via automatic address setting)

System without remote control is also available.

Interface adaptor for SkyAir series (DTA102A52 or DTA112BA51)

Connectable number of centralised control equipment

Central remotecontroller 2 units

Unified on /offcontroller 8 units

Schedule timer 1 unit

Outdoor-air processing unit can be connected.

1

Page 13: HEAT PUMP - Jaicrest Air Conditioningassets.jaicrest.com.au/downloads/brochures/daikin/Daikin VRVIII-S... · Ceiling Mounted Cassette (Round Flow) Type Model Name Capacity Range Capacity

12

Residential central remote controller* (Option)Max. 16 groups of indoor units can be easily controlled with the large LCD panel.

Max. 16 groups (128 indoor units) controllable

Backlight and large LCD panel for easy readability

ON/OFF, temperature settings and scheduling can be controlled individually for indoor units.

All indoor units can be turned on or off at once with “ALL” button.

Each group has a dedicated button for convenience.

Outside temperature display

Unified ON/OFF controller (Option)

Max. 16 groups of indoor units can be operated simultaneously/individually.

Max. 16 groups (128 indoor units) controllable

2 remote controllers can be used to control from 2 different places.

Operating status indication (Normal operation, Alarm)

Centralised control indication

Max. wiring length 1,000 m (Total: 2,000 m)

Compact size casing (Thickness: 16 mm)

Connectable with Central Remote controller, Schedule timer and BMS system

Schedule timer (Option)

Max. 128 indoor units can be operated as programmed schedule.

Max. 128 indoor units controllable

When used in combination with a central remote controller, a maximum of 8 weekly schedule

patterns can be set, while the central controller can be used to select desired zones. Up to 2

ON/OFF pairs can be set per day.

Max. 48 hours back up power supply

Max. wiring length 1,000 m (Total: 2,000 m)

Compact size casing (Thickness: 16 mm)

Connectable with Central Remote controller, Unified ON/OFF controller and BMS system

DCS303A51

DCS301BA61

DST301BA61

Max. 64 groups (zones) of indoor units can be controlled individually same as LCD Remote controller.

Max. 64 groups (128 indoor units) controllable

Max. 128 groups (128 indoor units) are controllable by using 2 central remote controllers,

which can control from 2 different places.

Zone control

Malfunction code display

Max. wiring length 1,000 m (Total: 2,000 m)

Connectable with Unified ON/OFF controller, schedule timer and BMS system

Airflow volume and direction can be controlled individually for indoor units in each group operation.

Ventilation volume and mode can be controlled for Heat Reclaim Ventilator.

Up to 4 ON/OFF pairs can be set per day by connecting a schedule timer.

DCS302CA61

Central remote controller (Option)

* For residential use only. Cannot be used with other centralised control equipment.

Page 14: HEAT PUMP - Jaicrest Air Conditioningassets.jaicrest.com.au/downloads/brochures/daikin/Daikin VRVIII-S... · Ceiling Mounted Cassette (Round Flow) Type Model Name Capacity Range Capacity

CONTROL SYSTEMS

13

Advanced control systems

One touch selection to total air comfort

Up to 2,560 groups (5,120 indoor units) can be controlled by one system

Air Conditioning Network Service System

Web Access

Web Access

LAN

Max. 50miTM plus adaptor line

Di/Pi port

Max. 500m

I/O expansion line

I/O System (Max. 30 modules)

iTM plus adaptor (Max. 7 adaptors)

I/O moduleI/O module I/O module

Lighting Pump Fan Sensor

InternetIntranet

System Architecture

Max. 64 groupsPhone line

LAN

Internal modem(option)

Fire alarm

Max. 200m

kWh meter

Di/Pi line

USB memory

line

DCM601A51

Daikin proudly introduces its new intelligent Touch Manager, a VRV system controller featuring an array of simple, useful system management functions for added value.

New

New

Features

• Handy area settings simplify detailed management of VRV.• Display of floor plans enables a quick search of desired air conditioning units.• Operation history shows manner of control and origin in past operations of air conditioning units.

Central control

• Remote access with a PC allows total air conditioning management using the same type of screens as those displayed in the intelligent Touch Manager.

• Authorised users can centrally control individual air conditioning units from their own computers.

Remote access

• VRVs are controlled automatically throughout the year by the schedule function.• Interlocking VRVs and other equipment enables easy automation of building facilities operation.• Setback adjusts temperature settings even when rooms are unoccupied.

Automatic control

• The Energy Navigator feature simplifies energy management by tracking energy consumption data and identifying inefficient operation.

Energy management

• Contact information of maintenance contractors can be registered and displayed.• E-mails are sent automatically to alert of malfunctions and potential trouble.• The intelligent Touch Manager can link to the Air Conditioning Network Service System for 24-hour monitoring of operating

conditions and status.

Troubleshooting

• A single intelligent Touch Manager can manage a small building or be expanded to handle medium- to large-sized buildings.• Large building properties can also take advantage of the iTM integrator to link up and expand system up to 5 intelligent Touch

Managers for integrated control.

Scalability

Page 15: HEAT PUMP - Jaicrest Air Conditioningassets.jaicrest.com.au/downloads/brochures/daikin/Daikin VRVIII-S... · Ceiling Mounted Cassette (Round Flow) Type Model Name Capacity Range Capacity

14

Communication functions in the user-friendly icon-based multilingual controller simplify centralised control of the VRV system.

FeaturesColour LCD touch panel icon display

Small manageable size

Simplified engineering

Multi language (English, French, Italian, German,

Spanish, Dutch, Portuguese, Chinese and Korean)

Yearly schedule

Auto heat/cool change-over

Temperature limitation

Enhanced history function

Simple Interlock Function

Built-in modem for connecting to Air Conditioning Network Service System (Option)

Management of facilities/equipment other than A/C units (By adding Dio unit or Di unit)

Doubling of number of connectable indoor units by adding a D -NET Plus Adaptor (Option)

Input (Lights)

Input (Key signal -General purpose ADP)

Dio UnitDEC102A51(Option)

Di UnitDEC101A51(Option)

System

Set temperature change command

OFFcommand

RS-232C

Air Conditioning NetworkService System modemfor connections

Number of indoor units expanded from 64 to 128.

D -NET

D -NET Plus AdaptorDCS601A52 (Option)

Indoor UnitHeat ReclaimVentilator

ACC centre• Air Conditioning Network Service System (Optional Maintenance Service)

System Components

Via internet

DCS601C51

System Architecture

Page 16: HEAT PUMP - Jaicrest Air Conditioningassets.jaicrest.com.au/downloads/brochures/daikin/Daikin VRVIII-S... · Ceiling Mounted Cassette (Round Flow) Type Model Name Capacity Range Capacity

INDOOR UNIT LINEUP

15

Ceiling Mounted Cassette(Round Flow) Type

FXFQ25P/FXFQ32P/FXFQ40PFXFQ50P/FXFQ63P/FXFQ80PFXFQ100P/FXFQ125P

360° airflow improves temperature distributionand offers a comfortable living environment.

Note: Whatever the discharge direction, the same type of panel is used. If installing for other than all-round flow, an air discharge outlet sealing member (option) must be used to close each unused outlet.

3-way flow L-shaped 2-way flowAll-round flow 4-way flow

850 mm

The industry’s first* Round Flow Ceiling Mounted Cassette type offers 360° airflow with improved temperature distribution.

All models are lighter than the conventional ones.Ex: Models FXFQ25P-50P are 4.5 kg lighter (reduced from 24 kg to 19.5 kg).

(dB(A))

A modern sophisticated decoration panel has been applied, with a panel surface that has been treated with a dirt-repellant coating.

An antibacterial treatment that uses silver ions has been applied to the drain pan, preventing the growth of slime, mould and bacteria that cause blockages and odours.

The horizontal louvres prevent dew condensation. Their non-flocking surfaces, which repel dirt, are easy to clean.

The air filter has an anti-mould and antibacterial treatment that prevents the growth of mould generated from dust or moisture that may adhere to the filter.

Example of airflow patterns:360° airflow is available, as well as 2- to 4-way flows, so you can choose the most suitable airflow pattern depending on location or room layout.

Drain pump is equipped as a standard accessory, and the lift height has been improved from 750 mm to 850 mm.

Treated surface Untreated surface

Resists soiling

• Condition after exposure to the smoke of 600 cigarettes in 1 m3 enclosed space.

Dirt andgrime

Control of the airflow rate has been improved from 2-step to 3-step control.

Low operation sound level

4-way flow Round Flow

There are areas of uneven temperature.

There are much fewerareas of uneven temperature.

* As of April 2004, the release date for Japan.

44/39/34

125

43/37.5/32

100

36/33.5/31

80

34/31/28

63

32/29.5/27

50

31/29/27

4025/32

30/28.5/27Soundlevel

(HH/H/L)

FXFQ-P

Page 17: HEAT PUMP - Jaicrest Air Conditioningassets.jaicrest.com.au/downloads/brochures/daikin/Daikin VRVIII-S... · Ceiling Mounted Cassette (Round Flow) Type Model Name Capacity Range Capacity

16

Quiet, compact, and designed for user comfort

Ceiling Mounted Cassette(Compact Multi Flow) Type

FXZQ20M/FXZQ25MFXZQ32M/FXZQ40MFXZQ50M

Dimensions correspond with 600 mm X 600 mm architectural module ceiling design specifications.

Wide discharge angle: 0° to 60°

2-, 3-, and 4-way airflow patterns are available, enabling installation in the corner of a room.

Comfortable airflow

Low operation sound level

60°

60°

Auto swing Fixed angles: 5 levels

Angles can be also set on site to prevent drafts (0°-35°) or soiling of the ceiling (25°-60°), other than standard setting (0°-60°).

For 3-way or 2-way flow installation, the sealing member for air dischargeoutlet (option) must be used to close each unused outlet.

750 mm

Drain pump is equipped as a standard accessory with 750 mm lift.

4-way flow 3-way flowL-shaped

2-way flow

1

2

0° 0°

60° 60°

(240 V)(dB(A))

32/26Sound level

(H/L)

20/25 32 40 50

34/28 37/29 42/35

FXZQ-M

Page 18: HEAT PUMP - Jaicrest Air Conditioningassets.jaicrest.com.au/downloads/brochures/daikin/Daikin VRVIII-S... · Ceiling Mounted Cassette (Round Flow) Type Model Name Capacity Range Capacity

INDOOR UNIT LINEUP

17

Designed with higher airflow suitable for high ceiling application up to 3 metres.

Providing 2 different settings of standard and ceiling soiling prevention, the auto swing mechanism achieves even distribution of airflow and room temperature.

Drain pump is equipped as a standard accessory with 600 mm lift.

Major maintenance work can be performed by removing the panel. A flat-type suction grille and a detachable blade make cleaning easy.

Ceiling Mounted Cassette(Double Flow) Type

FXCQ20M/FXCQ25M/FXCQ32MFXCQ40M/FXCQ50M/FXCQ63MFXCQ80M/FXCQ125M

Thin, lightweight, and easy to install in shallow ceiling spaces

FXCQ-M 20 25/32 6340/50 80 125

34/29 36/30 39/3437/32 41/36 46/40

(240 V)(dB(A))Low operation sound level

Sound level (H/L)

600 mm

305 mm

The low profile unit (only 305 mm high) can be installed in a ceiling space as shallow as 350 mm. All models feature a compact design with a depth of only 600 mm.

(When a high-efficiency filter is attached, the unit's height is 400 mm.)

Two types of optional high-efficiency filter are available (65% and 95%, colourimetric method).

A long-life filter (maintenance free up to one year*) is equipped as a standard accessory.

* 8 hr/day, 25 day/month. For dust concentration of 0.15 mg/m3

Page 19: HEAT PUMP - Jaicrest Air Conditioningassets.jaicrest.com.au/downloads/brochures/daikin/Daikin VRVIII-S... · Ceiling Mounted Cassette (Round Flow) Type Model Name Capacity Range Capacity

18

Ceiling Mounted CassetteCorner Type

Slim design for flexible installation

3

32˚C 30˚C28˚C 26˚C 24˚C

22˚C

20˚C

2

1

0 1 2 3 4 5 6 (m)

(m)

Main body

Air discharge grille (Option)

Set for front discharge using a suspended ceiling.

Downward discharge is shut off and air is blown straight out (front discharge).

Single-flow type allows effective air discharge from corner or from drop-ceiling.

Front discharge is possible with an air discharge unit (option), which allows the installation in the drop-ceiling or sagging wall.

Slim body needs only 220 mm space above the ceiling. If you use a panel spacer (option), the unit can be installed in the minimum space of 195 mm.

Providing 3 different settings of standard, draft prevention and ceiling soiling prevention, the auto swing mechanism achieves even distribution of airflow and room temperature.

Drain pump is equipped as a standard accessory with 500 mm lift.

Main body

Downward discharge

Air discharge grille (Option)

FXKQ25MA/FXKQ32MAFXKQ40MA/FXKQ63MA

500 mm

Panel spacer

20 mm

Min.195 mm

A long-life filter (maintenance free up to one year*) is equipped as a standard accessory.

* 8 hr/day, 25 day/month. For dust concentration of 0.15 mg/m3

Page 20: HEAT PUMP - Jaicrest Air Conditioningassets.jaicrest.com.au/downloads/brochures/daikin/Daikin VRVIII-S... · Ceiling Mounted Cassette (Round Flow) Type Model Name Capacity Range Capacity

INDOOR UNIT LINEUP

19

Slim Ceiling MountedDuct Type

Slim design, quietness and static pressure switching

External static pressure selectable by remote controller switching make this indoor unit a very comfortable and flexible model.10 Pa-30 Pa/factory set: 10 Pa for FXDQ-PB models.15 Pa-44 Pa/factory set: 15 Pa for FXDQ-NB models.

Only 200 mm in height, this model can be installed in rooms with as little as 240 mm depth between the drop-ceiling and ceiling slab.

Only 700 mm in width and 23 kg in weight, this model is suitable to install in limited spaces like drop-ceilings in hotels.

1,100 mm in width for the FXDQ63NB model.

200 mm900 mm

Suction grille*AIR

AIR

Discharge grille*

Air filterSuspension bolt*

240 mm

* To be obtained locally

Only 700 mm

200 mm

Great for hotel use!

Suited for use in drop-ceilings!

Drain pump is equipped as a standard accessory with 750 mm lift.

750 mm

Ceiling

FXDQ20PB/FXDQ25PB/FXDQ32PBFXDQ40NB/FXDQ50NB/FXDQ63NB

Low operation sound level (dB(A))

The values of operation sound level represent those for rear-suction operation.Sound level values for bottom-suction operation can be obtained by adding 5 dB(A). Values are based on the following conditions:FXDQ-PB: external static pressure of 10 Pa; FXDQ-NB: external static pressure of 15 Pa.

Control of the airflow rate has been improved from 2-step to 3-step control.

36/34/32

63

35/33/31

50

34/32/30

40

33/31/29

20/25/32

Sound level(HH/H/L)

FXDQ-PB/NB

Page 21: HEAT PUMP - Jaicrest Air Conditioningassets.jaicrest.com.au/downloads/brochures/daikin/Daikin VRVIII-S... · Ceiling Mounted Cassette (Round Flow) Type Model Name Capacity Range Capacity

20

Ceiling MountedBuilt-in Type

Highly flexible for various application

250 mm

Min.350 mm

Highly flexible installation is possible with a complete lineup of optional kits to satisfy various needs, such as the design concept, interior decoration and so on.

The unit can be installed, if there is a space of 350 mm above ceiling. (when suction panel is used.)

Drain pump is equipped as a standard accessory with 250 mm lift.

High external static pressure allows the use of flexible ducts of various length.

Low operation sound level

41/33.5Sound level

(H/L)

20/25/32 40 50 63 80/100 125

41/34.5 43/37 45/38.5 48/43 49/41.5

(230 V)(dB(A))

FXSYQ-M

Standard

With duct

Cassette style (standard filter)

Cassette style (high efficiency filter)

Long-life filter

Long-life filter

Air suction canvas bellows

Air suction panel

Air suction panel

Access panel

Access panel

Air suction canvas bellows

Ceiling return

Long-life filter

Screening door

High efficiencyfilter

Installation examples ( Optional parts)

The values of operation sound level are based on Australian Standard 1217.6-1985. Measurement is based on bottom-return air entry.

FXSYQ20M/FXSYQ25M/FXSYQ32MFXSYQ40M/FXSYQ50M/FXSYQ63MFXSYQ80M/FXSYQ100M/FXSYQ125M

Page 22: HEAT PUMP - Jaicrest Air Conditioningassets.jaicrest.com.au/downloads/brochures/daikin/Daikin VRVIII-S... · Ceiling Mounted Cassette (Round Flow) Type Model Name Capacity Range Capacity

INDOOR UNIT LINEUP

21

Ceiling Concealed(Duct) Type

High static pressure offers flexible duct designthat blends in with interior décor in stores and offices

FXDYQ80MA/FXDYQ100MAFXDYQ125MA/FXDYQ145MA

Quiet yet powerful supply air fan.

High external static pressure of 120 Pa allows comprehensive duct layout for various applications.

Two external static pressure settings for added flexibility.

Hi-X heat exchanger coils provide even more energy efficiency.

Design of indoor units allows installation in limited roof spaces.

Return air spigots included for ease of installation.

High strength galvanised steel casing.

Page 23: HEAT PUMP - Jaicrest Air Conditioningassets.jaicrest.com.au/downloads/brochures/daikin/Daikin VRVIII-S... · Ceiling Mounted Cassette (Round Flow) Type Model Name Capacity Range Capacity

22

Ceiling MountedDuct Type

Improved ease of installation

Improved ease of maintenance

Middle and high static pressureallows for flexible duct design

All models are only 300 mm in height, an improvement over the 390 mm height of conventional models. The weight of the FXMQ40P has been reduced from 44 kg to 28 kg.

A DC fan motor increases the external static pressure capacity range to include middle to high static pressures, increasing design flexibility.

FXMQ20P/FXMQ25P/FXMQ32PFXMQ40P/FXMQ50P/FXMQ63PFXMQ80P/FXMQ100P/FXMQ125PFXMQ140P

Drain pump is equipped as a standard accessory with 700 mm lift.

Control of the airflow rate has been improved from 2-step to 3-step control.

(dB(A))

700 mm

Ceiling

30 Pa–100 Pa for FXMQ20P-32P30 Pa–160 Pa for FXMQ40P50 Pa–200 Pa for FXMQ50P-125P50 Pa–140 Pa for FXMQ140P

Low operation sound level

300 mm

Easy installation in buildings with narrow ceiling spaces

Airflow rate can be controlled using a remote controller during test operation. With the conventional model, the airflow rate was controlled from the PC board. It is automatically adjusted to the range between approximately ±10% of the rated HH tap airflow for FXMQ20P-125P.

Energy-efficient

The adopted DC fan motor is much more efficient than the conventional AC motor, yielding an approximate 20% decrease in energy consumption (FXMQ125P).

The drain pan can be detached for easy cleaning. An antibacterial treatment that uses silver ions has been applied to the drain pan, preventing the growth of slime, mould and bacteria that cause blockages and odours.

46/45/43

140

42/40/38

63

43/41/39

80/100

41/39/37

50

39/37/35

40

34/32/30

32

33/31/29

20/25

Soundlevel

(HH/H/L)

FXMQ-P

44/42/40

125

Page 24: HEAT PUMP - Jaicrest Air Conditioningassets.jaicrest.com.au/downloads/brochures/daikin/Daikin VRVIII-S... · Ceiling Mounted Cassette (Round Flow) Type Model Name Capacity Range Capacity

INDOOR UNIT LINEUP

Ceiling Suspended Type

23

Slim body with quiet and wide airflow

Adoption of QUIET STREAM FAN

Drain pump kit (option) can be easily incorporated.

Easy-to-clean flat design

Maintenance is easier because servicing can be performed from below the unit.

Non-dew Flap with no implanted bristles

Uses the quiet stream fan and many advanced technologies.

Sound absorptionmaterial

Turbulent flow is produced

Straightening vane

Quiet stream fan

Installation is easy

Maintenance is easy

Bristle-free Flap minimises contamination and makes cleaning simpler.

Non-dew Flap

100°

Wide air discharge openings produce a spreading 100° airflow.

FXHQ32MA/FXHQ63MAFXHQ100MA

FXHQ-MA

Sound level(H/L)

32

36/31

63

39/34

100

45/37

(dB(A))Low operation sound level

Drain pump kit(Built inside main unit)

600 mm

A long-life filter (maintenance free up to one year*) is equipped as a standard accessory.* 8 hr/day, 25 day/month. For dust concentration of 0.15 mg/m3

Page 25: HEAT PUMP - Jaicrest Air Conditioningassets.jaicrest.com.au/downloads/brochures/daikin/Daikin VRVIII-S... · Ceiling Mounted Cassette (Round Flow) Type Model Name Capacity Range Capacity

24

Wall Mounted Type

Stylish flat panel design harmonised with your interior décor

FXAQ20P/FXAQ25PFXAQ32P/FXAQ40PFXAQ50P/FXAQ63P

New

Drain pan and air filter can be kept clean by mould-proof polystyrene.

Drain pump kit is available as optional accessory, which lifts the drain 1,000 mm from the bottom of the unit.

Vertical auto-swing realises efficiency of air distribution. The louvre closes automatically when the unit stops.

5 steps of discharge angle can be set by remote controller.

Discharge angle is automatically set at the same angle as the previous operation when restarting. (Initial setting: 10˚ for cooling and 70˚ for heating)

Flexible installationDrain pipe can be fitted to from either left or right sides. Drain pump kit

1,000 mm

Height of drain-up

Indoor unit

Stylish flat panel design creates a graceful harmony that enhances any interior space.

Flat panel can be cleaned with only the single pass of a cloth across their smooth surface.Flat panel can also be easily removed and washed for more thorough cleaning.

Low operation sound level

47/41

63

42/37

50

39/34

40

38/31

32

36/31

25

35/31

20

Sound level(H/L)

FXAQ-P

(dB(A))

Page 26: HEAT PUMP - Jaicrest Air Conditioningassets.jaicrest.com.au/downloads/brochures/daikin/Daikin VRVIII-S... · Ceiling Mounted Cassette (Round Flow) Type Model Name Capacity Range Capacity

INDOOR UNIT LINEUP

Floor Standing Type

25

Suitable for perimeter zone air conditioning

Wall hanging Floor installation

Floor Standing types can be hung on the wall for easier floor cleaning. Running the piping from the back allows the unit to be hung on walls. Cleaning under the unit, where dust tends to accumulate, is considerably easier.

The adoption of a fibre-less discharge grille featuring an original design to prevent condensation also helps prevent staining and makes cleaning easier.

Concealed FloorStanding Type

Designed to be concealed in the perimeter skirting-wall

Connecting port

Refrigerant piping

Applies also to Floor Standing type (FXLQ-MA).

The unit is concealed in skirting-wall of perimeter, that enables to create high class interior design.

The connecting port faces downward, greatly facilitating on-site piping work.

FXNQ20MA/FXNQ25MAFXNQ32MA/FXNQ40MAFXNQ50MA/FXNQ63MA

FXLQ20MA/FXLQ25MAFXLQ32MA/FXLQ40MAFXLQ50MA/FXLQ63MA

A long-life filter (maintenance free up to one year*) is equipped as a standard accessory.* 8 hr/day, 25 day/month. For dust concentration of 0.15 mg/m3

A long-life filter (maintenance free up to one year*) is equipped as a standard accessory.* 8 hr/day, 25 day/month. For dust concentration of 0.15 mg/m3

Page 27: HEAT PUMP - Jaicrest Air Conditioningassets.jaicrest.com.au/downloads/brochures/daikin/Daikin VRVIII-S... · Ceiling Mounted Cassette (Round Flow) Type Model Name Capacity Range Capacity

26

Ceiling SuspendedCassette Type

This thin indoor unit achieves optimumair distribution, and can be installedwithout the need for ceiling cavity

FXUQ71MAFXUQ100MAFXUQ125MA

Connection unit Connection unit is the device for connecting above indoor unit to VRVIII-S.

Depending on installation site requirements or room conditions, 2-way, 3-way and 4-way discharge patterns are available.

4-way airflowfrom the centre of the store.

The 3-way airflow can distributecomfortable air throughout the room.

Only one unit is needed to distribute comfortable airthroughout an L-shaped store.

BEVQ-MA

Connection unit for indoor unit

Indoor unitPiping length*1

Indoor unit

Remote controller

Super wiring (DIII-NET)

Single-phase 220-240 Vpower supply

VRV -S series outdoor unit

Refrigerant piping layout External wiring layout

Notes:

Gas pipeLiquid pipe

ModelMaximum piping lengthbetween the BEV unitand the indoor unit.

FXUQ-MA 5 m

*1

• When connecting centralised-control device, it is necessary to install an interface adaptor for an indoor unit (DTA102A52).

• Connection unit BEVQ-MA is necessary for each indoor unit.

• The refrigerant piping height difference between the indoor units and the BEV unit must be within 4 m.

• The BEV unit must be installed within a maximum height difference between indoor units of 15 m.

• Branching of the refrigerant piping is not possible downstream of the BEV unit.

BEVQ71MA/BEVQ100MA/BEVQ125MA

Page 28: HEAT PUMP - Jaicrest Air Conditioningassets.jaicrest.com.au/downloads/brochures/daikin/Daikin VRVIII-S... · Ceiling Mounted Cassette (Round Flow) Type Model Name Capacity Range Capacity

SPECIFICATIONS

27

INDOOR UNITSCeiling Mounted Cassette (Round Flow) Type

Ceiling Mounted Cassette (Compact Multi Flow) Type

FXFQ25PVE

2.9

9,900

2,500

3.2

10,900

Galvanised steel plate

2,800

6.4

12.7

VP25 (External Dia, 32/Internal Dia, 25)

BYCP125K-W1

Fresh white

50X950X950

5.5

50X950X950

5.5

50X950X950

5.5

50X950X950

5.5

50X950X950

5.5

50X950X950

5.5

50X950X950

5.5

50X950X950

5.5

6.4

12.7

FXFQ32PVE

3.7

12,600

3,200

4.0

13,600

3,400

250/216/183216/191/166 216/191/166

6.4

12.7

FXFQ40PVE

4.7

16,000

4,000

5.0

17,100

4,300

266/225/183

6.4

12.7

FXFQ50PVE

5.8

19,800

5,000

6.3

21,500

5,400

316/275/225

9.5

15.9

FXFQ63PVE

7.3

24,900

6,300

8.0

27,300

6,900

350/300/250

9.5

15.9

FXFQ80PVE

9.3

2.8 3.6 4.5 5.6 7.1 9.0

31,700

8,000

10.0

34,100

8,600

FXFQ100PVE

11.6

39,600

10,000

12.5

42,700

10,800

FXFQ125PVE

14.5

11.2 14.0

49,500

12,500

16.0

54,600

13,800

533/433/333

9.5

15.9

550/466/375

9.5

15.9

Heating capacity

kW

Btu/h

kcal/h

Casing

1-phase, 220-240 V/220 V, 50/60 Hz

Airflow rate (HH/H/L) /s

48/46.5/45 48/46.5/45 49/47/45 50/47.5/45 52/49/46 53/51.5/49 60/54.5/50 61/56/52dB(A)Sound power (HH/H/L)

Power consumption

kWCooling

Heating

0.033 0.033 0.047 0.052 0.066 0.093 0.187 0.209

0.027 0.027 0.034 0.038 0.053 0.075 0.174 0.200

15/13/1113/11.5/10 13/11.5/10 16/13.5/11 19/16.5/13.5 21/18/15 32/26/20 33/28/22.5m3/min

30/28.5/27 30/28.5/27 31/29/27 32/29.5/27 34/31/28 36/33.5/31 43/37.5/32 44/39/34

246X840X840

19.5

246X840X840

19.5

246X840X840

19.5

246X840X840

19.5

246X840X840

22

246X840X840

22

288X840X840

25

288X840X840

25

MODEL

Cooling capacity

kW(*1)

(*2)

Btu/h(*1)

kcal/h(*1)

Power supply

Dimensions (HXWXD) mm

Machine weight kg

Pipingconnections

Drain

Panel(Option)

Model

Colour

mmDimensions (HXWXD)

Weight kg

Liquid (Flare)

Gas (Flare) mm

dB(A)Sound level (HH/H/L)

MODEL

kW(*1) 2.3

150/116

Btu/h(*1)

kcal/h(*1)

Heating capacitykW

Btu/h

9/7

FXZQ25MVE

2.9

9,900

2,500

3.2

10,900

2,800

150/116

9/7

FXZQ32MVE

3.7

12,600

3,200

4.0

13,600

3,400

158/125

9.5/7.5

FXZQ40MVE

4.7

(*2) 2.8 3.6 4.5

16,000

4,000

5.0

17,100

4,300

183/133

11/8

286X575X575

18

6.4

12.7

VP20 (External Dia, 26/Internal Dia, 20)

BYFQ60B8W1

White (6.5Y9.5/0.5)

55X700X700

2.7

6.4

12.7

55X700X700

2.7

6.4

12.7

55X700X700

2.7

6.4

12.7

55X700X700

2.7

Dimensions (HXWXD) mm

Machine weight kg

kcal/h

Casing

Power supply

Airflow rate (H/L)

Cooling capacity

FXZQ50MVE

5.8

5.6

19,800

5,000

6.3

21,500

5,400

233/166

14/10

6.4

12.7

55X700X700

2.7

m3/min

/s

8,500

2,200

Galvanised steel plate

2.5

7,800

2,000

1-phase, 220-240 V/220 V, 50 Hz/60 Hz

FXZQ20MVE

2.2

Sound power (H) dB(A)240 V 49 49 51 54 59

Sound level (H/L) dB(A)240 V 32/26 32/26 34/28 37/29 42/35

Power consumption kW

Cooling

Heating 0.064

0.073

0.064

0.073

0.068

0.076

0.080

0.089

0.107

0.115

Pipingconnections

Drain

Panel(Option)

Model

Colour

mmDimensions (HXWXD)

Weight kg

Liquid (Flare)

Gas (Flare) mm

Note: Specifications are based on the following conditions;•Cooling: (*1) Indoor temp.: 27°CDB, 19.5°CWB, Outdoor temp.: 35°CDB, Equivalent piping length: 7.5 m, Level difference: 0 m. (*2) Indoor temp.: 27°CDB, 19°CWB, Outdoor temp.: 35°CDB, Equivalent piping length: 7.5 m, Level difference: 0 m.•Heating: Indoor temp.: 20°CDB, Outdoor temp.: 7°CDB, 6°CWB, Equivalent piping length: 7.5 m, Level difference: 0 m.•Capacity of indoor unit is only for reference. Actual capacity of indoor unit is based on the total capacity index. (See Engineering Data Book for details.)•Sound level: Anechoic chamber conversion value, measured at a point 1.5 m downward from the unit centre. During actual operation, these values are normally somewhat higher as a result of ambient conditions.

Page 29: HEAT PUMP - Jaicrest Air Conditioningassets.jaicrest.com.au/downloads/brochures/daikin/Daikin VRVIII-S... · Ceiling Mounted Cassette (Round Flow) Type Model Name Capacity Range Capacity

28

INDOOR UNITSCeiling Mounted Cassette (Double Flow) Type

Ceiling Mounted Cassette Corner Type

FXCQ20MVE FXCQ25MVE FXCQ32MVE FXCQ40MVE FXCQ50MVE FXCQ63MVE FXCQ80MVE FXCQ125MVE

2.3

7,800

2,000

2.5

8,500

Galvanised steel plate

2,200

116/83

305X775X600

26

6.4

12.7

VP25 (External Dia, 32/Internal Dia, 25)

BYBC32G-W1

White (10Y9/0.5)

53X1,030X680

8.0

2.9

9,900

2,500

3.2

10,900

2,800

150/108

305X775X600

26

6.4

12.7

53X1,030X680

8.0

3.7

12,600

3,200

4.0

13,600

3,400

150/108

305X775X600

26

6.4

12.7

53X1,030X680

8.0

4.7

16,000

4,000

5.0

17,100

4,300

200/150

305X990X600

31

6.4

12.7

BYBC50G-W1

53X1,245X680

8.5

5.8

19,800

5,000

6.3

21,500

5,400

200/150

305X990X600

32

6.4

12.7

53X1,245X680

8.5

7.3

24,900

6,300

8.0

27,300

6,900

275/216

305X1,175X600

35

9.5

15.9

BYBC63G-W1

53X1,430X680

9.5

9.3

31,700

8,000

10.0

34,100

8,600

433/350

305X1,665X600

47

9.5

15.9

BYBC125G-W1

53X1,920X680

12.0

14.5

2.2 2.8 3.6 4.5 5.6 7.1 9.0 14.0

49,500

12,500

16.0

54,600

13,800

550/416

34/29 36/30 36/30 37/32 37/32 39/34 41/36 46/40

305X1,665X600

48

9.5

15.9

53X1,920X680

12.0

Heating capacity

kW

Btu/h

kcal/h

Casing

1-phase, 220-240 V/220 V, 50/60 Hz

Airflow rate (H/L)/s

Sound level (H/L) 240 V dB(A)

0.077 0.092 0.092 0.130 0.130 0.161 0.209 0.256

0.044 0.059 0.059 0.097 0.097 0.126 0.176 0.223

7/5 9/6.5 9/6.5 12/9 12/9 16.5/13 26/21 33/25m3/min

Power consumption

kWCooling

Heating

MODEL

Cooling capacity

kW(*1)

(*2)

Btu/h(*1)

kcal/h(*1)

Power supply

Dimensions (HXWXD) mm

Machine weight kg

Pipingconnections

Drain

Panel(Option)

Model

Colour

mmDimensions (HXWXD)

Weight kg

Liquid (Flare)

Gas (Flare) mm

kW(*1)

Btu/h(*1)

kcal/h(*1)

(*2)

Power supply

Cooling capacity

MODEL

Dimensions (HXWXD) mm

Machine weight kg

Pipingconnections

Drain

Panel(Option)

Model

Colour

mm

kg

Dimensions (HXWXD)

Liquid (Flare)

Gas (Flare) mm

Weight

FXKQ25MAVE

2.9

9,900

2,500

3.2

10,900

Galvanised steel plate

2,800

183/150

Heating capacity

kW

Btu/h

FXKQ32MAVE

3.7

12,600

3,200

4.0

13,600

3,400

FXKQ40MAVE

4.7

16,000

4,000

5.0

17,100

4,300

FXKQ63MAVE

7.3

2.8 3.6 4.5 7.1

24,900

6,300

8.0

27,300

6,900

183/150 216/166 300/250

kcal/h

Casing

1-phase, 220-240 V/220 V, 50/60 Hz

Airflow rate (H/L) /s

215X1,110X710

31

6.4

12.7

VP25 (External Dia, 32/Internal Dia, 25)

BYK45FJW1

White (10Y9/0.5)

70X1,240X800

8.5

215X1,110X710

31

6.4

12.7

70X1,240X800

8.5

215X1,110X710

31

6.4

12.7

70X1,240X800

8.5

215X1,310X710

34

9.5

15.9

BYK71FJW1

70X1,440X800

9.5

40/35 40/35 42/36 44/39Sound level (H/L) 240 V dB(A)

Power consumption kW

Cooling

Heating

0.066 0.066 0.076 0.105

0.046 0.046 0.056 0.085

11/9 11/9 13/10 18/15m3/min

Note: Specifications are based on the following conditions;•Cooling: (*1) Indoor temp.: 27°CDB, 19.5°CWB, Outdoor temp.: 35°CDB, Equivalent piping length: 7.5 m, Level difference: 0 m. (*2) Indoor temp.: 27°CDB, 19°CWB, Outdoor temp.: 35°CDB, Equivalent piping length: 7.5 m, Level difference: 0 m.•Heating: Indoor temp.: 20°CDB, Outdoor temp.: 7°CDB, 6°CWB, Equivalent piping length: 7.5 m, Level difference: 0 m.•Capacity of indoor unit is only for reference. Actual capacity of indoor unit is based on the total capacity index. (See Engineering Data Book for details.)•Sound level: (FXCQ-M) Anechoic chamber conversion value, measured at a point 1.5 m downward from the unit centre.

(FXKQ-MA) Anechoic chamber conversion value, measured at a point 1 m in front of the unit and 1 m downward. During actual operation, these values are normally somewhat higher as a result of ambient conditions.

Page 30: HEAT PUMP - Jaicrest Air Conditioningassets.jaicrest.com.au/downloads/brochures/daikin/Daikin VRVIII-S... · Ceiling Mounted Cassette (Round Flow) Type Model Name Capacity Range Capacity

SPECIFICATIONS

29

INDOOR UNITS

Slim Ceiling Mounted Duct Type (700 mm width type)

Slim Ceiling Mounted Duct Type (900/1,100 mm width type)

Galvanised steel plate

7,800

2,000

9,900

2,500

12,600

3,200

2.2

133/120/106 133/120/106 133/120/106

33/31/29 33/31/29 33/31/29

8,500

2,200

10,900

2,800

13,600

3,400

Btu/h

2.5 3.2 4.0kW

kcal/h

Heating capacity

1-phase, 220-240 V/220 V, 50/60 HzPower supply

200X700X620

23

6.4

12.7

200X700X620

23

6.4

12.7

200X700X620

23

6.4

12.7

51 51 51dB(A)Sound power (HH)

2.8 3.6

2.3 2.9 3.7

VP20 (External Dia, 26/Internal Dia, 20)

30-10 1

MODEL FXDQ20PBVE FXDQ25PBVE FXDQ32PBVE

0.067 0.067 0.070

0.086 0.086 0.089

8.0/7.2/6.4 8.0/7.2/6.4 8.0/7.2/6.4

Cooling capacity

kW(*1)

(*2)

Btu/h(*1)

kcal/h(*1)

Dimensions (HXWXD) mm

Machine weight kg

Pipingconnections

Drain

Liquid (Flare)

Gas (Flare) mm

Cooling

Heating

Airflow rate (HH/H/L) /s

m3/min

dB(A)

Casing

Sound level (HH/H/L)

PaExternal static pressure

32

Power consumption

kW

Galvanised steel plate

16,000

4,000

19,800

5,000

24,900

6,300

17,100

4,300

21,500

5,400

27,300

6,900

Btu/h

5.0 6.3 8.0kW

kcal/h

175/158/141 208/183/166 275/241/216

34/32/30 35/33/31 36/34/32

Heating capacity

1-phase, 220-240 V/220 V, 50/60 HzPower supply

200X900X620

27

6.4

12.7

200X900X620

28

6.4

12.7

200X1,100X620

31

9.5

15.9

52 53 54dB(A)Sound power (HH)

4.5 5.6 7.1

4.7 5.8 7.3

VP20 (External Dia, 26/Internal Dia, 20)

44-15 1

MODEL FXDQ40NBVE FXDQ50NBVE FXDQ63NBVE

0.160 0.165 0.181

0.147 0.152 0.168

10.5/9.5/8.5 12.5/11.0/10.0 16.5/14.5/13.0

Cooling capacity

kW(*1)

(*2)

Btu/h(*1)

kcal/h(*1)

Dimensions (HXWXD) mm

Machine weight kg

Pipingconnections

Drain

Liquid (Flare)

Gas (Flare) mm

Casing

Cooling

Heating

Power consumption

kW

Airflow rate (HH/H/L) /s

m3/min

dB(A)Sound level (HH/H/L)

PaExternal static pressure

32

1: External static pressure is changeable to set by the remote controller. This pressure means "High static pressure - Standard".(Factory setting is 10 Pa for FXDQ-PB models and 15 Pa for FXDQ-NB models.)2: The values of operation sound level represent those for rear-suction operation. Sound level values for bottom-suction operation can be obtained by adding 5 dB(A).3: Values are based on the following conditions: FXDQ-PB: external static pressure of 10 Pa; FXDQ-NB: external static pressure of 15 Pa.

Note: Specifications are based on the following conditions;•Cooling: (*1) Indoor temp.: 27°CDB, 19.5°CWB, Outdoor temp.: 35°CDB, Equivalent piping length: 7.5 m, Level difference: 0 m. (*2) Indoor temp.: 27°CDB, 19°CWB, Outdoor temp.: 35°CDB, Equivalent piping length: 7.5 m, Level difference: 0 m.•Heating: Indoor temp.: 20°CDB, Outdoor temp.: 7°CDB, 6°CWB, Equivalent piping length: 7.5 m, Level difference: 0 m.•Capacity of indoor unit is only for reference. Actual capacity of indoor unit is based on the total capacity index. (See Engineering Data Book for details.)•Sound level: Anechoic chamber conversion value, measured at a point 1.5 m downward from the unit centre. During actual operation, these values are normally somewhat higher as a result of ambient conditions.

Page 31: HEAT PUMP - Jaicrest Air Conditioningassets.jaicrest.com.au/downloads/brochures/daikin/Daikin VRVIII-S... · Ceiling Mounted Cassette (Round Flow) Type Model Name Capacity Range Capacity

30

INDOOR UNITSCeiling Mounted Built-in Type

Ceiling Concealed (Duct) Type

1-phase, 220-240 V, 50 Hz

FXDYQ80MAV1 FXDYQ100MAV1 FXDYQ125MAV1 FXDYQ145MAV1

8.8

31,700

8,000

11.2

39,600

10,000

13.9

49,500

12,500

16.0

9.3 11.6 14.5 16.9

57,600

14,500

Galvanised steel plate

9.9

33,800

8,480

510

30.6

12.5

42,700

10,800

778

46.7

16.0

54,600

13,800

852

51.1

18.4

62,800

15,800

957

57.4

120 120 120 120

VP25 (External Dia, 32/Internal Dia, 25)

360X1168X869

50

9.5

15.9

360X1478X899

60

9.5

15.9

360X1478X899

65

9.5

15.9

360X1478X899

66

9.5

15.9

45 46 48 51

3 3 3 3

0.415

0.415

0.700

0.700

0.780

0.780

0.880

0.880

MODEL

Cooling capacity

(*2)

Btu/h(*1)

kcal/h(*1)

Power supply

(*1)kW

Pa

Heating capacity

kW

Btu/h

kcal/h

/s

m3/min

External static pressure (H)

Casing

Airflow rate (H)

240 VSound level (H)

Dimensions (HXWXD) mm

Machine weight kg

Piping connections

Drain

dB(A)

Liquid (Flare)

Gas (Flare) mm

Power consumption kW

Cooling

Heating

Galvanised steel plate

FXSYQ20MVE FXSYQ25MVE FXSYQ32MVE FXSYQ40MVE FXSYQ50MVE FXSYQ63MVE FXSYQ80MVE FXSYQ100MVE FXSYQ125MVE

7,900

2,000

2.5

8,500

2,200

9,900

2,500

3.2

10,900

2,800

12,600

3,200

4.0

13,600

3,400

16,000

4,000

5.0

17,100

4,300

19,800

5,000

6.3

21,500

5,400

24,900

6,300

8.0

27,300

6,900

31,700

8,000

10.0

34,100

8,600

39,600

10,000

12.5

42,700

10,800

2.2

49,500

12,500

16.0

54,600

13,800

kW

Btu/h

kcal/h

150/112 150/112 158/112 191/143 250/190 350/235 450/355 466/370 633/457

Casing

1-phase, 220-240 V, 50 Hz

41/33.5 41/34.5 48/43 48/43 49/41.543/37 45/38.541/33.5 41/33.5Sound level (H/L)

2.8 3.6 4.5 5.6 7.1 9.0 11.2 14.0

2.3 2.9 3.7 4.7 5.8 7.3 9.3 11.6 14.5

Heating capacity

300X550X800

30

6.4

12.7

VP25 (External Dia, 32/Internal Dia, 25)

300X550X800

30

6.4

12.7

300X550X800

30

6.4

12.7

300X700X800

34

6.4

12.7

300X700X800

35

6.4

12.7

300X1,000X800

44

9.5

15.9

300X1,400X800

57

9.5

15.9

300X1,400X800

57

9.5

15.9

300X1,400X800

57

9.5

15.9

White (10Y9/0.5)

55X650X500

3.0

55X650X500

3.0

55X650X500

3.0

55X800X500

3.5

55X800X500

3.5

55X1,100X500

4.5

55X1,500X500

6.5

55X1,500X500

6.5

55X1,500X500

6.5

BYBS32DJW1 BYBS32DJW1 BYBS32DJW1 BYBS45DJW1 BYBS45DJW1 BYBS71DJW1 BYBS125DJW1 BYBS125DJW1 BYBS125DJW1

230 V dB(A)

58/50.5 58/51.5 65.5/60 65.5/60 66/5960/54 62/55.558/50.5 58/50.5Sound power (H/L) 230 V dB(A)

98-65-33 98-65-33 88-57-27 96-65-57 86-58-43 115-84-52 140-122-61 138-118-53 98-5811 1 1 1 1 1 21

Power consumption kW

Cooling

Heating 0.089 0.089 0.096 0.106 0.145 0.178 0.304 0.309 0.366

0.089 0.089 0.096 0.106 0.145 0.178 0.304 0.309 0.366

9/6.72 9/6.72 9.5/6.72 11.5/8.58 15/11.4 21/14.1 27/21.3 28/22.2 38/27.42

kW(*1)

Btu/h(*1)

kcal/h(*1)

(*2)

Power supply

Cooling capacity

MODEL

External static pressure Pa

Airflow rate (H/L) /s

m3/min

Dimensions (HXWXD) mm

Machine weight kg

Pipingconnections

Drain

Panel(Option)

Model

Colour

mm

kg

Dimensions (HXWXD)

Liquid (Flare)

Gas (Flare) mm

Weight

Note: Specifications are based on the following conditions;•Cooling: (*1) Indoor temp.: 27°CDB, 19.5°CWB, Outdoor temp.: 35°CDB, Equivalent piping length: 7.5 m, Level difference: 0 m. (*2) Indoor temp.: 27°CDB, 19°CWB, Outdoor temp.: 35°CDB, Equivalent piping length: 7.5 m, Level difference: 0 m.•Heating: Indoor temp.: 20°CDB, Outdoor temp.: 7°CDB, 6°CWB, Equivalent piping length: 7.5 m, Level difference: 0 m.•Capacity of indoor unit is only for reference. Actual capacity of indoor unit is based on the total capacity index. (See Engineering Data Book for details.)•Sound level: (FXSYQ) Anechoic chamber conversion value, based on Australian Standard 1217.6-1985. Measurement is based on bottom-return air entry. (FXDYQ) Anechoic chamber conversion value, measured at a point 1.5 m downward from the unit centre. During actual operation, these values are normally somewhat higher as a result of ambient conditions.•For FXDYQ models, an air filter is not a standard accessory. A suitable locally obtained filter must be installed in the return air duct. 1: External static pressure is changeable to change over the connectors inside electrical box, this pressure means "High static pressure-Standard-Low static pressure". 2: External static pressure is changeable to change over the connectors inside electrical box, this pressure means "High static pressure-Standard". 3: External static pressure is changeable to change over the connectors inside electrical box (High static pressure-Standard static pressure). The data above is for high static pressure setting.

Page 32: HEAT PUMP - Jaicrest Air Conditioningassets.jaicrest.com.au/downloads/brochures/daikin/Daikin VRVIII-S... · Ceiling Mounted Cassette (Round Flow) Type Model Name Capacity Range Capacity

SPECIFICATIONS

31

INDOOR UNITSCeiling Mounted Duct Type

FXMQ40PVE FXMQ50PVE

4.7

16,000

4,000

5.0

17,100

Galvanised steel plate

4,300

267/216/183

300X700X700

28

VP25 (External Dia, 32/Internal Dia, 25)

5.8

19,800

5,000

6.3

21,500

5,400

300/275/250

300X1,000X700

36

4.5 5.6

Heating capacity

kW

Btu/h

kcal/h

/s

External static pressure

Casing

1-phase, 220-240 V/220 V, 50/60 Hz

6.4

12.7

6.4

12.7

Power consumption kW

Heating

Cooling 0.194 0.215

0.182 0.203

Airflow rate (HH/H/L)16/13/11 18/16.5/15m3/min

Pa 30-160 50-2001 1

39/37/35

FXMQ20PVE

2.3

7,800

2,000

2.5

8,500

2,200

150/125/108

300X550X700

25

2.2

6.4

12.7

0.081

0.069

9/7.5/6.5

30-100

33/31/29

FXMQ25PVE

2.9

9,900

2,500

3.2

10,900

2,800

150/125/108

300X550X700

25

2.8

6.4

12.7

0.081

0.069

9/7.5/6.5

30-100

33/31/29

FXMQ32PVE

3.7

12,600

3,200

4.0

13,600

3,400

158/133/116

300X550X700

25

3.6

6.4

12.7

0.085

0.073

9.5/8/7

30-100

34/32/30 41/39/37Sound level (HH/H/L) dB(A)

5751 51 52 59Sound power (H) dB(A)

(*1)

(*2)

MODELPower supply

Cooling capacity

kW

Btu/h(*1)

kcal/h(*1)

Drain

Dimensions (HXWXD) mm

Machine weight kg

Pipingconnections

Liquid (Flare)

Gas (Flare) mm

1 1 1

FXMQ63PVE FXMQ80PVE FXMQ100PVE FXMQ125PVE

Galvanised steel plate

VP25 (External Dia, 32/Internal Dia, 25)

7.3

24,900

6,300

8.0

27,300

6,900

325/292/267

300X1,000X700

36

9.5

15.9

9.3

31,700

8,000

10.0

34,100

8,600

417/375/333

300X1,000X700

36

9.5

15.9

11.6

39,600

10,000

12.5

42,700

10,800

533/450/383

300X1,400X700

46

9.5

15.9

14.5

49,500

12,500

16.0

54,600

13,800

650/550/466

300X1,400X700

46

9.5

15.9

7.1 9.0 11.2 14.0

Heating capacity

kW

Btu/h

kcal/h

/s

External static pressure

Casing

1-phase, 220-240 V/220 V, 50/60 Hz

Power consumption kW

Heating

Cooling 0.230 0.298 0.376 0.461

0.218 0.286 0.364 0.449

Airflow rate (HH/H/L)19.5/17.5/16 25/22.5/20 32/27/23 39/33/28m3/min

Pa 50-200 50-200 50-200 50-200 1 1 1 1

42/40/38 43/41/39 43/41/39 44/42/40

FXMQ140PVE

16.7

57,000

14,300

18.0

61,400

15,500

766/649/533

300X1,400X700

47

9.5

15.9

16.0

0.461

0.449

46/39/32

50-140 1

46/45/43Sound level (HH/H/L) dB(A)

60 61 61 62 64Sound power (H) dB(A)

(*1)

(*2)

MODELPower supply

Cooling capacity

kW

Btu/h(*1)

kcal/h(*1)

Drain

Dimensions (HXWXD) mm

Machine weight kg

Liquid (Flare)

Gas (Flare) mmPipingconnections

Note: Specifications are based on the following conditions;•Cooling: (*1) Indoor temp.: 27°CDB, 19.5°CWB, Outdoor temp.: 35°CDB, Equivalent piping length: 7.5 m, Level difference: 0 m. (*2) Indoor temp.: 27°CDB, 19°CWB, Outdoor temp.: 35°CDB, Equivalent piping length: 7.5 m, Level difference: 0 m.•Heating: Indoor temp.: 20°CDB, Outdoor temp.: 7°CDB, 6°CWB, Equivalent piping length: 7.5 m, Level difference: 0 m.•Capacity of indoor unit is only for reference. Actual capacity of indoor unit is based on the total capacity index. (See Engineering Data Book for details.)•Sound level: Anechoic chamber conversion value, measured at a point 1.5 m downward from the unit centre. During actual operation, these values are normally somewhat higher as a result of ambient conditions. 1: External static pressure can be modified using a remote controller that offers seven (FXMQ20-32P), thirteen (FXMQ40P), fourteen (FXMQ50-

125P) or ten (FXMQ140P) levels of control. These values indicate the lowest and highest possible static pressures. The standard static pressure is 50 Pa for FXMQ20-32P and 100 Pa for FXMQ40-140P.

Page 33: HEAT PUMP - Jaicrest Air Conditioningassets.jaicrest.com.au/downloads/brochures/daikin/Daikin VRVIII-S... · Ceiling Mounted Cassette (Round Flow) Type Model Name Capacity Range Capacity

32

INDOOR UNITSCeiling Suspended Type

MODELPower supply

Cooling capacity

kW(*1)

(*2)

Btu/h(*1)

kcal/h(*1)

m3/min

Dimensions (HXWXD) mm

Machine weight kg

/sAirflow rate (H/L)

dB(A)Sound level (H/L)

Pipingconnections

Drain

Liquid (Flare)

Gas (Flare) mm

FXHQ32MAVE

3.7

12,600

3,200

4.0

13,600

White (10Y9/0.5)

3,400

FXHQ63MAVE

7.3

24,900

6,300

8.0

27,300

6,900

FXHQ100MAVE

11.6

3.6 7.1 11.2

39,600

10,000

12.5

42,700

10,800

Heating capacity

kW

Btu/h

kcal/h

200/166 291/233 416/325

195X960X680

24

6.4

12.7

VP20 (External Dia, 26/Internal Dia, 20)

195X1,160X680

28

9.5

15.9

195X1,400X680

33

9.5

15.9

Casing

1-phase, 220-240 V/220 V, 50/60 Hz

36/31 39/34 45/37

kW0.111 0.115 0.135

0.111 0.115 0.135

12/10 17.5/14 25/19.5

Power consumption

Cooling

Heating

Wall Mounted Type

Note : Specifications are based on the following conditions;•Cooling: Indoor temp.: (*1) 27°CDB, 19.5°CWB, Outdoor temp.: 35°CDB, Equivalent piping length: 7.5 m, Level difference: 0 m. (*2) 27°CDB, 19°CWB, Outdoor temp.: 35°CDB, Equivalent piping length: 7.5 m, Level difference: 0 m.•Heating: Indoor temp.: 20°CDB, Outdoor temp.: 7°CDB, 6°CWB, Equivalent piping length: 7.5 m, Level difference: 0 m.•Capacity of indoor unit is only for reference. Actual capacity of indoor unit is based on the total capacity index. (See Engineering Data Book for details.)•Sound level : Anechoic chamber conversion value, measured at a point 1 m in front of the unit and 1 m downward. During actual operation, these values are normally somewhat higher as a result of ambient conditions.

FXAQ25PVE

2.9

3.2

White (3.0Y8.5/0.5)

36/31

290X795X238

11

Casing

1-phase, 220-240/220V, 50/60Hz

38/31

290X795X238

11

FXAQ40PVE

4.7

5.0

39/34

290X1,050X238

14

9,900 16,000

2,500 4,000

10,900 17,100

2,800 4,300

Airflow rate (H/L)

13,600

3,400

FXAQ32PVE

3.7

12,600

3,200

4.0

2.8

FXAQ20PVE

2.3

2.5

35/31

290X795X238

11

7,800

2,000

8,500

2,200

2.2 4.53.6

VP13 (External Dia, 18/Internal Dia, 13)

6.4 6.4 6.4 6.4

12.7 12.7 12.7 12.7

42/37

290X1,050X238

14

FXAQ63PVE

7.3

24,900

6,300

27,300

6,900

8.0

47/41

290X1,050X238

14

21,500

5,400

6.3

5,000

FXAQ50PVE

5.8

19,800

7.15.6

6.4 9.5

12.7 15.9

0.028 0.030 0.020 0.033 0.0500.019

0.034 0.035 0.020 0.039 0.0600.029

Heating capacity

kW

Btu/h

kcal/h

MODELPower supply

Cooling capacity

kW(*1)

(*2)

Btu/h(*1)

kcal/h(*1)

Dimensions (HXWXD) mm

Machine weight kg

dB(A)Sound level (H/L)

Pipingconnections

Drain

Liquid (Flare)

Gas (Flare) mm

Power consumption kW

Heating

Cooling

8/5 8.5/5.5 12/9

/s

m3/min

133/83 142/91

7.5/4.5

125/75 200/150 250/200 316/233

15/12 19/14

Page 34: HEAT PUMP - Jaicrest Air Conditioningassets.jaicrest.com.au/downloads/brochures/daikin/Daikin VRVIII-S... · Ceiling Mounted Cassette (Round Flow) Type Model Name Capacity Range Capacity

SPECIFICATIONS

/s

33

INDOOR UNITS

Connection unit series indoor units

Ceiling Suspended Cassette Type

kW(*1)

(*2)

Kcal/h(*1)

Power supply

8.3

7,100

1-phase, 220-240 V, 50 Hz

Btu/h(*1) 28,300

kW

Kcal/h

Heating capacity (Max.)

9.0

7,700

Btu/h 30,700

Ind

oo

r u

nit Airflow rate (H/L)

Sound power (H)

Casing

dB(A)

mmDimensions (HXWXD)

kgMachine weight

56

Piping connections

Liquid

Gas

Drain VP 20 (External Dia. 26/Internal Dia. 20)

25

White(10Y9/0.5)

316/233

165X895X895

9.5 (Flare)

15.9 (Flare)

11.6

10,000

39,600

12.5

10,800

42,700

59

31

483/350

230X895X895

14.5

8.0 11.2 14.0

12,500

49,500

14.0

12,000

47,800

60

Sound level (H/L) dB(A) 40/35 43/38 44/39

31

533/383

230X895X895

mm

Cooling capacity

MODELIndoor unit

Connection unit BEVQ71MAVE

FXUQ71MAV1

BEVQ100MAVE

FXUQ100MAV1

BEVQ125MAVE

FXUQ125MAV1

* A type of BEV unit is necessary for each Connection unit series indoor unit. Refer to the Engineering Data Book for details.* If indoor units from the Connection unit series are connected within a single refrigerant system to indoor units from any other series, cooling/heating switchover will

not be possible using the remote controller of the Connection unit series indoor units. However, if the remote controller of an indoor unit from the other series is set as a master remote controller, cooling/heating switchover will be possible.

* If all indoor units are from the Connection unit series, an outdoor unit Cool/Heat selector will be needed to enable cooling/heating switchover. * Group control between Connection Unit series equipment within one system is possible. However, group control with the other VRV indoor units is not possible.

kWPowerconsumption 0.169

0.189

0.278

0.298

0.278

0.298Cooling

Heating

m3/min 19/14 29/21 32/23

230 V

Floor Standing Type/Concealed Floor Standing Type

FXLQ

FXNQ

FXLQ20MAVE

2.3

7,800

2,000

8,500

FXLQ:Ivory white (5Y7.5/1) / FXNQ:Galvanised steel plate

2,200

Heating capacity

kW

Btu/h

kcal/h

Casing

Airflow rate (H/L) /s 116/100

600X1,000X222

25

6.4

12.7

21O.D.

2.2

FXLQ25MAVE

2.9

9,900

2,500

10,900

2,800

116/100

600X1,000X222

25

6.4

12.7

2.8

FXLQ32MAVE

3.7

12,600

3,200

13,600

3,400

133/100

600X1,140X222

30

6.4

12.7

3.6

FXLQ40MAVE

4.7

16,000

4,000

17,100

4,300

183/141

600X1,140X222

30

6.4

12.7

4.5

FXLQ50MAVE

5.8

19,800

5,000

6.3

21,500

5,400

233/183

600X1,420X222

36

6.4

12.7

5.6

FXLQ63MAVE

FXNQ20MAVE FXNQ25MAVE FXNQ32MAVE FXNQ40MAVE FXNQ50MAVE FXNQ63MAVE

7.3

24,900

6,300

8.0

27,300

6,900

266/200

600X1,420X222

610X930X220 610X930X220 610X1,070X220 610X1,070X220 610X1,350X220 610X1,350X220

36

19 19 23 23 27 27

9.5

15.9

7.1

2.5 3.2 4.0 5.0

37/34 37/34 37/34 40/35 41/36 42/37

1-phase, 220-240 V/220 V, 50/60 Hz

Sound level (H/L) dB(A)240 V

0.049 0.049 0.090 0.090 0.110 0.110

0.049 0.049 0.090 0.090 0.110 0.110

m3/min 7/6 7/6 8/6 11/8.5 14/11 16/12

kWPower consumption

Cooling

Heating

MODEL

Power supply

Cooling capacity

kW(*1)

(*2)

Btu/h(*1)

kcal/h(*1)

Dimensions (HXWXD)

Machine weight

mmFXLQ

FXNQ

kgFXLQ

FXNQ

Pipingconnections

Drain

Liquid (Flare)

Gas (Flare) mm

Note: Specifications are based on the following conditions;•Cooling: (*1) Indoor temp.: 27°CDB, 19.5°CWB, Outdoor temp.: 35°CDB, Equivalent piping length: 7.5 m, Level difference: 0 m. (*2) Indoor temp.: 27°CDB, 19°CWB, Outdoor temp.: 35°CDB, Equivalent piping length: 7.5 m, Level difference: 0 m.•Heating: Indoor temp.: 20°CDB, Outdoor temp.: 7°CDB, 6°CWB, Equivalent piping length: 7.5 m, Level difference: 0 m.•Capacity of indoor unit is only for reference. Actual capacity of indoor unit is based on the total capacity index. (See Engineering Data Book for details.)•Sound level: (FXLQ-MA,FXNQ-MA) Anechoic chamber conversion value, measured at a point 1 m in front of the unit and 1 m downward.

(FXUQ-MA) Anechoic chamber conversion value, measured at a point 1.5 m in front of the unit at a height of 1.5 m.During actual operation, these values are normally somewhat higher as a result of ambient conditions.

Page 35: HEAT PUMP - Jaicrest Air Conditioningassets.jaicrest.com.au/downloads/brochures/daikin/Daikin VRVIII-S... · Ceiling Mounted Cassette (Round Flow) Type Model Name Capacity Range Capacity

34

OUTDOOR UNITS

Heat PumpMODEL

ø15.9 (Flare)

Note: Specifications are based on the following conditions;• Cooling: Indoor temp.: 27°CDB, 19.5°CWB, Outdoor temp.: 35°CDB, Equivalent piping length: 7.5 m, Level difference: 0 m.• Heating: Indoor temp.: 20°CDB, Outdoor temp.: 7°CDB, 6°CWB, Equivalent piping length: 7.5 m, Level difference: 0 m.• Sound level: Anechoic chamber conversion value, measured at a point 1 m in front of the unit at a height of 1.5 m. During actual operation, these values are normally somewhat higher as a result of ambient conditions.• Refrigerant charge is required.

68

9,600

RXYMQ4PV4A

50/52

10,800

38,200

42,700

11.2

12.5

2.95

3.27

2.5

71

13,300

RXYMQ6PV4A

ø19.1 (Brazing)

53/55

15,500

52,900

61,400

15.5

18.0

4.44

4.82

3.5

1-phase, 230–240 V, 50 Hz

24 to 100

Hermetically sealed scroll type

1,345 x 900 x 320

125

ø9.5 (Flare)

69

R-410A

-5 to 46-20 to 15.5

12,000

RXYMQ5PV4A

51/53

13,800

47,800

54,600

14.0

16.0

3.97

4.09

4.0

106

3.0

Ivory white (5Y7.5/1)

1,766

%

m3/min

mm

Kcal/h

Kcal/h

kg

kW

mm

dB(A)

kg

dB(A)

kW

°CWB

°CDB

Btu/h

Btu/h

kW

kW

/s

Motor output

Type

Liquid

Gas

Charge

Type

Heating

Cooling

Heating

Cooling

Power supply

Cooling capacity

Capacity control

Casing colour

Compressor

Dimensions (H x W x D)

Heating capacity

Machine weight

Piping connections

Sound power

Operation range

Refrigerant

Sound level (Cooling/Heating)

Power consumption

Airflow rate

Page 36: HEAT PUMP - Jaicrest Air Conditioningassets.jaicrest.com.au/downloads/brochures/daikin/Daikin VRVIII-S... · Ceiling Mounted Cassette (Round Flow) Type Model Name Capacity Range Capacity

OPTION LIST

35

Ceiling Mounted Cassette (Double Flow) Type

No.

1

2

Decoration PanelHigh efficiency filter 65% 1

High efficiency filter 90% 1

Long life replacement filter

Filter related bottom suction

FXCQ20MFXCQ25MFXCQ32M

FXCQ40M FXCQ50M FXCQ63M FXCQ80M FXCQ125M

KAFJ532G36 KAFJ532G56 KAFJ532G160KAFJ532G80KAFJ533G36 KAFJ533G56 KAFJ533G160KAFJ533G80KDDFJ53G36Filter chamber KDDFJ53G56 KDDFJ53G160KDDFJ53G80KAFJ531G36 KAFJ531G56 KAFJ531G160KAFJ531G80

Type

ItemBYBC32G-W1 BYBC50G-W1 BYBC125G-W1BYBC63G-W1

Note: 1 Filter chamber is required if installing high efficiency filter.

Ceiling Mounted Cassette Corner Type

Ceiling Mounted Cassette (Compact Multi Flow) Type

INDOOR UNITS

Ceiling Mounted Cassette (Round Flow) Type

Slim Ceiling Mounted Duct Type (900/1,100 mm width type)Type

No. FXDQ20PB FXDQ25PB FXDQ32PB

1 KDT25N32Insulation kit for high humidity

Slim Ceiling Mounted Duct Type (700 mm width type)TypeItem

No.

1 KDT25N50 KDT25N63Insulation kit for high humidity

TypeItem FXDQ63NBFXDQ50NBFXDQ40NB

FXFQ25P FXFQ32P FXFQ40P FXFQ50P FXFQ63P FXFQ80P FXFQ100P FXFQ125PNo. TypeItem

1

4

BYCP125K-W1

KAFP556B80 KAFP556B160KAFP557B80 KAFP557B160KAFP552B80 KAFP552B160KAFP553B80 KAFP553B160

KDTP55K160

KDJP55B160

Filter related

5 Fresh air intake kit

Decoration panel2 KDBH55K160FSealing member of air discharge outlet3 KDBP55H160FAPanel spacer

High efficiency filter unit 65%High efficiency filter unit 90%Replacement high efficiency filter 65%Replacement high efficiency filter 90%Filter chamberLong life replacement filter Non-woven type

Chamber typeWithout T shape and fanWith T shape without fan

KDDFP55B160

Ultra long-life filterReplacement ultra long-life filter

Direct installation type

KAFP551K160KAFP55B160

KAFP55H160HKDDP55B160

KDDP55B160KKDDP55X160

6 KDJP55B80Branch duct chamber7 KKSJ55KA160Chamber connection kit8 KDTP55K80Insulation kit for high humidity

No. FXZQ20M FXZQ25M FXZQ32M FXZQ40M FXZQ50M1 Decoration panel2 Sealing member of air discharge outlet3 Panel spacer4 Replacement long-life filter

BYFQ60B8W1KDBH44BA60

KDBQ44BA60AKAFQ441BA60

5 Fresh air intake kit Direct installation type KDDQ44XA60

TypeItem

No. TypeItem FXKQ25MA FXKQ32MA FXKQ40MA FXKQ63MA

1

2

BYK45FJW1 BYK71FJW1KPBJ52F56W KPBJ52F80WKAFJ521F56 KAFJ521F80

K-HV7AW K-HV9AWKDBJ52F56W KDBJ52F80WKFDJ52FA56 KFDJ52FA80

Panel related

Air inlet and air discharge outlet related

Decoration panelPanel spacerLong life replacement filterAir discharge grilleAir discharge blind panelFlexible duct (with shutter)

Page 37: HEAT PUMP - Jaicrest Air Conditioningassets.jaicrest.com.au/downloads/brochures/daikin/Daikin VRVIII-S... · Ceiling Mounted Cassette (Round Flow) Type Model Name Capacity Range Capacity

36

INDOOR UNITS

Ceiling Suspended Type

Wall Mounted TypeFXAQ25PFXAQ20P

1 Drain pump kit K-KDU572EVE

FXAQ32P FXAQ40P FXAQ50P FXAQ63PNo. TypeItem

Floor Standing TypeFXLQ20MA

1 Long life replacement filter

FXLQ25MA FXLQ32MA FXLQ40MA FXLQ50MA FXLQ63MA

KAFJ361K28 KAFJ361K45 KAFJ361K71

No. TypeItem

Ceiling Concealed (Duct) TypeFXDYQ80MA

1 Run/fault status PCB KRP1B5X

FXDYQ100MA FXDYQ125MA FXDYQ145MANo. TypeItem

Ceiling Mounted Built-in Type

Ceiling Mounted Duct Type

FXSYQ20MFXSYQ25MFXSYQ32M

1BYBS32DJW1

KTBJ25K36W

FXSYQ40MFXSYQ50M

BYBS45DJW1

KTB25KA56W

FXSYQ63M

BYBS71DJW1

KTB25KA80W

FXSYQ80MFXSYQ100MFXSYQ125MBYBS125DJW1

KTB25KA160WPanel related

Decoration panel

Access panel

2

KAFJ252L36

KAFJ253L36

KAF252LA56

KAF253LA56

KAF252LA80

KAF253LA80

KAF252LA160

KAF253LA160Filter related

High efficiency filter 65%

High efficiency filter 90%

KAFJ251K36 KAFJ251K56 KAFJ251K80 KAFJ251K160

KAJ25L36D KAJ25LA56D KAJ25LA80D KAJ25LA160D

Long life replacement filter

KSA-25K36

KBBJ25K36

KSA-25KA56

KBBJ25KA56

KSA-25KA80

KBBJ25KA80

KSA-25KA160

KBBJ25KA160

Air suction canvas

Screening door3 Air inlet related

Filter chamber for bottom suction

No.Type

Item

Note: 1 If installing a high efficiency filter in the Ceiling Mounted Built-in type, a filter chamber for bottom suction is required.

1

1

No. FXMQ40PFXMQ50PFXMQ63PFXMQ80P

FXMQ20PFXMQ25PFXMQ32P

FXMQ100PFXMQ125PFXMQ140P

FXMQ200MAFXMQ250MA

KDU30L250VE—

KAFJ372L280KAF372AA80 KAF372AA160

KAFJ373L280KAF373AA80 KAF373AA160

KDJ3705L280KDDF37AA80 KDDF37AA160

KAFJ371L280KAF371AA80 KAF371AA160

KAF375AA80

KAF372AA56

KAF373AA56

KDDF37AA56

KAF371AA56

KAF375AA56

KAF372AA36

KAF373AA36

KDDF37AA36

KAF371AA36

KAF375AA36 KAF375AA160

KTB25KA80W KTB25KA160W

KTBJ25K80F KTBJ25K160F

KTBJ25K80T

KTB25KA56W

KTBJ25K56F

KTBJ25K56T

KTBJ25K36W

KTBJ25K36F

KTBJ25K36T KTBJ25K160T

KDAJ25K71AKDAJ25K56AKDAJ25K36A KDAJ25K140A

Item1 Drain pump kit

3 Filter chamber

2 High efficiency filter65%

90%

4 Long life replacement filter

5 Long life filter chamber kit

6 Service panel

White

Fresh white

Brown

7 Air discharge adaptor

Type

FXHQ32MA

1 Drain pump kit

2 Replacement long-life filter (Resin net)

KDU50N60VE

KAF501DA56

3 L-type piping kit (for upward direction) KHFP5MA63

FXHQ63MA

KDU50N125VE

KAF501DA80

KHFP5MA160

FXHQ100MA

KAF501DA112

No. TypeItem

Page 38: HEAT PUMP - Jaicrest Air Conditioningassets.jaicrest.com.au/downloads/brochures/daikin/Daikin VRVIII-S... · Ceiling Mounted Cassette (Round Flow) Type Model Name Capacity Range Capacity

OPTION LIST

37

Heat PumpNo.

1

1-1

2

3

RXYMQ4P

KJB111A

KHRP26M22H (Max. 4 branch)

KHRP26M33H (Max. 8 branch)

KHRP26A22T

KRC19-26A

RXYMQ5P RXYMQ6P

5 KPT-60B160

6 K-KYZP15C

4 KKPJ5F180

Concealed Floor Standing TypeFXNQ20MA

1 Long life replacement filter

FXNQ25MA FXNQ32MA FXNQ40MA FXNQ50MA FXNQ63MA

KAFJ361K28 KAFJ361K45 KAFJ361K71

No. TypeItem

Ceiling Suspended Cassette Type

Item

CONTROL SYSTEMS

INDOOR UNITS

OUTDOOR UNITS

Operation Control System Optional AccessoriesNo.

3

4

Remote controllerWireless

Simplified remote controller (Exposed type)

5 Adaptor for wiring

6-1 Wiring adaptor for electrical appendices (1)

6-2 Wiring adaptor for electrical appendices (2)

Remote controller for hotel use (Concealed type)

7 Remote sensor (for indoor temperature)

9 External control adaptor for outdoor unit

TypeItem

8 Installation box for adaptor PCB

1

Note: 1. Installation box is necessary for each adaptor marked .2. Up to 2 adaptors can be fixed for each installation box.

5. Installation box is necessary for second adaptor.6. Installation box is necessary for each adaptor.

3. Only one installation box can be installed for each indoor unit.4. Up to 2 installation boxes can be installed for each indoor unit.

FXFQ-P

BRC7F634F

KRP1C63

KRP2A62

KRP4AA53

KRCS01-4B

10 Adaptor for multi tenant — DTA114A61DTA114A61DTA114A61 ——

Note 2,3KRP1H98

DTA104A62

FXZQ-M

BRC7E530W

KRP1BA57

KRP2A62

KRP4AA53

KRCS01-1B KRCS01-4B KRCS01-1B

Note 4,6KRP1BA101

FXCQ-M

BRC7C62

KRP1B61

KRP2A61

KRP4AA51

Note 2,3KRP1B96

DTA104A61

FXKQ-MA

BRC4C61

KRP1B61

KRP2A61

KRP4AA51

DTA104A61

FXDQ-PBFXDQ-NB

BRC4C65

BRC2C51

BRC3A61

KRP1B56

KRP2A53

KRP4A54

Note 4,6KRP1BA101

DTA104A53

FXSYQ-M

BRC4C62

KRP1B61

KRP2A61

KRP4AA51

Note 5KRP4A91

FXDYQ-MA

BRC4C62

KRP1B61

KRP2A61

KRP4AA51

DTA104A61

FXMQ-P

BRC4C65

KRP1C64

KRP2A61

KRP4AA51

Note 2,3KRP4A96

DTA104A61

FXHQ-MA

BRC7EA63W

KRP1BA54

KRP2A62

KRP4AA52

Note3KRP1CA93

DTA104A62

FXAQ-P

BRC7EA618

KRP2A61

KRP4AA51

Note 2,3KRP4AA93

DTA104A61

FXLQ-MAFXNQ-MA

BRC4C62

BRC2C51

BRC3A61

KRP1B61

KRP2A61

KRP4AA51

DTA104A61

FXUQ-MA

BRC7CA528W

KRP4AA53

KRP1BA97

No.

Replacement long-life filter1

2

3

4

5

Sealing member of air discharge outlet (*1)

Decoration panel for air discharge

Vertical flap kit

L-shape piping kit

FXUQ71MA

KDBH49FA80

KDBT49FA80

KDGJ49FA80

KHFP49MA140

KDBH49FA140

KDBT49FA140

KDGJ49FA140

FXUQ100MA FXUQ125MA

KAF495FA140

(*1): This option is necessary for setting up 2-way (opposing directional) airflow when the air conditioner is installed.Note:

TypeItem

Wired BRC1C62

Wired remote controller with weekly schedule timer2 BRC1D61

Cool/Heat selector

Fixing box

REFNET header

REFNET joint

Fixture for preventing overturning

Wire fixture for preventing overturning

Central drain plug

TypeItem

Page 39: HEAT PUMP - Jaicrest Air Conditioningassets.jaicrest.com.au/downloads/brochures/daikin/Daikin VRVIII-S... · Ceiling Mounted Cassette (Round Flow) Type Model Name Capacity Range Capacity

38

CONTROL SYSTEMS

Building Management System

System ConfigurationNo. Item Model No. Function

•Interface unit to allow communications between VRV and BMS. Operation and monitoring of air-conditioning systems through LONWORKS® communication.DMS504B514

3

•Expansion kit, installed on DMS502B51, to provide 2 more DIII-NET communication ports. Not usable independently.DAM411B513-1

No. Item Model No. Function

*2 Interface for use in LONWORKS®

•Interface unit to allow communications between VRV and BMS. Operation and monitoring of air-conditioning systems through BACnet ® communication.DMS502B51

•Additional 64 groups (10 outdoor units) is possible. Max. 7 iTM plus adaptors can be connected to intelligent Touch Manager.DCM601A52

*1 Interface for use in BACnet®

Optional DIII board

KJB411A

•Expansion kit, installed on DMS502B51, to provide 16 more wattmeter pulse input points. Not usable independently.DAM412B51Optional Di board

•8 pairs based on a pair of On/Off input and abnormality input.DEC101A51Di unit2-5

3-2

1-2

1

Electrical box with earth terminal (4 blocks)

DCS601A521-1 •Additional 64 groups (10 outdoor units) is possible.

•Wall embedded switch box.

DCS601C51 •Air-Conditioning management system that can be controlled by a compact all-in-one unit.intelligent Touch Controller

DIII-NET plus adaptor

intelligent Touch Controller

Hardware

HardwareBasic

DCM601A51 •Air-conditioning management system that can be controlled by touch screen.intelligent Touch Manager

DCM601A53 •Max. 5 intelligent Touch Managers can be integrated.iTM integrator

HardwareBasic

Option

iTM plus adaptor

•Building energy consumption is visualised. Wasted air-conditioning energy can be found out.DCM008A51iTM energy navigator

•Power consumption of indoor units are calculated based on operation status of the indoor unit andoutdoor unit power consumption measured by kWh metre.DCM002A51iTM power proportional

distribution

2

2-2

2-1

2-4

2-3

Hardware

Software

Option

•4 pairs based on a pair of On/Off input and abnormality input.DEC102A51Dio unit2-6

•Interface between the central monitoring board and central control units.DCS302A525 Unification adaptor forcomputerised control

Notes: *1. BACnet® is a registered trademark of American Society of Heating, Refrigerating and Air-Conditioning Engineers (ASHRAE).

*2. LONWORKS® is a trademark of Echelon Corporation registered in the United States and other countries. *3. Installation box for adaptor must be obtained locally.

Communication line

Contact/analoguesignal

intelligent Touch Manager

•Up to 64 groups of indoor units(128 units) can be connected, and ON/OFF, temperature setting and monitoring can be accomplished individually or simultaneously. Connectable up to 2 controllers in one system.

Note 2

DCS302CA61Central remote controller2

•Up to 16 groups of indoor units (128 units) can be easily controlled using the large LCD panel. ON/OFF, temperature settings and scheduling can be controlled individually for indoor units.

Note 3

DCS303A51Residential central remote controller1

•Up to 16 groups of indoor units(128 units) can be turned, ON/OFF individually or simultaneously, and operation and malfunction can be displayed. Can be used in combination with up to 8 controllers.

Note 2

DCS301BA61Unified ON/OFF controller3

KJB212AAElectrical box with earth terminal (2 blocks)3-1

KEK26-1ANoise filter (for electromagnetic interface use only)3-2

KJB311AAElectrical box with earth terminal (3 blocks)2-1

DTA102A52Interface adaptor for SkyAir series5

DTA107A556

DTA103A51Wiring adaptor for other air-conditioner7

•Up to 1024 units can be centrally controlled in 64 different groups.•Wiring restrictions (max. length: 1,000 m, total wiring length: 2,000 m, max. number of branches: 16) apply to each adaptor.

DTA109A51D -NET

Expander Adaptor8

•Fixing plate for DTA109A51KRP4A92Mounting plate8-1

•Adaptors required to connect products other than those of the VRV System to the high-speed DIII-NET communication system adopted for the VRV System.

* To use any of the above optional controllers, an appropriate adaptor must be installed on the product unit to be controlled.For UAT(Y)-K(A),FD-K

For SkyAir, FD(Y)M-FA, FDY-KA,

FDYB-KA, FVY(P)J-A, FXUQ-MA

Central control adaptor kit

DTA112BA51For SkyAir FFQ-B, FHQ-BV,

FAQ100BV, FBQ-B

Notes: 1. Installation box for adaptor must be obtained locally. 2. For FXUQ-MAV1, an interface adaptor (DTA102A52) for the SkyAir series is necessary. 3. For residential use only. Cannot be used with other centralised control equipment.

•Programmed time weekly schedule can be controlled by unified control for up to 64 groups of indoor units (128 units). Can turn units ON/OFF twice per day.

Note 2

DST301BA61Schedule timer4

Page 40: HEAT PUMP - Jaicrest Air Conditioningassets.jaicrest.com.au/downloads/brochures/daikin/Daikin VRVIII-S... · Ceiling Mounted Cassette (Round Flow) Type Model Name Capacity Range Capacity

All rights reservedPrinted in Australia 09/12 Y.K.c

DealerHead Office:Umeda Center Bldg., 2-4-12, Nakazaki-Nishi,Kita-ku, Osaka, 530-8323 Japan

Tokyo Office:JR Shinagawa East Bldg., 2-18-1, Konan,Minato-ku, Tokyo, 108-0075 Japan

http://www.daikin.com/global_ac/

Specifications, designs and other content appearing in this brochure are current as of September 2012 but subject to change without notice.

1. Air conditioners should not be installed in areas where corrosive gases, such as acid gas or alkaline gas, are produced.2. If the outdoor unit is to be installed close to the sea shore, direct exposure to the sea breeze should be avoided. If you need to install the outdoor unit close to the sea shore, contact your local distributor.

Cautions on product corrosion

Warning Daikin products are manufactured for export to numerous countries throughout the world. Prior to purchase, please confirm with your local authorised importer, distributor and/or retailer whether this product conforms to the applicable standards, and is suitable for use, in the region where the product will be used. This statement does not purport to exclude, restrict or modify the application of any local legislation.

Ask a qualified installer or contractor to install this product. Do not try to install the product yourself. Improper installation can result in water or refrigerant leakage, electrical shock, fire or explosion and may have resultant impacts on warranty.

Use only those parts and accessories supplied or specified by Daikin. Ask a qualified installer or contractor to install those parts and accessories. Use of unauthorised parts and accessories or improper installation of parts and accessories can result in water or refrigerant leakage, electrical shock, fire or explosion.

Read the User's Manual carefully before using this product. The User's Manual provides important safety instructions and warnings. Be sure to follow these instructions and warnings.

If you have any enquiries, please contact your local importer, distributor and/or retailer.

Daikin AustraliaPty Limited (ISO9001)

QEC23256 May 31, 2006Sydney, Brisbane, Adelaide,

Melbourne, Newcastle, Townsville, Perth, Auckland

Daikin AustraliaPty Limited (ISO14001)

CEM20437 October 27, 2006Sydney, Brisbane, Melbourne,

Adelaide

JQA-1452JMI-0107

Organization:DAIKIN INDUSTRIES, LTD.AIR CONDITIONING MANUFACTURING DIVISION

Scope of Registration:THE DESIGN/DEVELOPMENT AND MANUFACTURE OF COMMERCIAL AIR CONDITIONING, HEATING, COOLING, REFRIGERATING EQUIPMENT, HEATING EQUIPMENT, RESIDENTIAL AIR CONDITIONING EQUIPMENT, HEAT RECLAIM VENTILATION, AIR CLEANING EQUIPMENT, COMPRESSORS AND VALVES.

Organization:DAIKIN INDUSTRIES (THAILAND) LTD.

Scope of Registration:THE DESIGN/DEVELOPMENT AND MANUFACTURE OF AIR CONDITIONERS AND THE COMPONENTS INCLUDING COMPRESSORS USED FOR THEM

All of the Daikin Group’s business facilities and subsidiaries in Japan are certified under the ISO 14001 international standard for environment management.