Heat Pump Range
All Thermoscreens products are certified in accordance with CE regulationsand where applicable comply with the following standards:
EN 60335-2-30, 89/336/EEC Electromagnetic Compatibility (EMC),Machinery Directive (89/392/EEC, as amended by 91/368/EEC, 93/44/EEC and 93/68/EEC)
Low Voltage Directive, (72/23/EEC as amended by 93/68/EEC)IP21 Rating CSA - Standard 22.2 UL 2021 / UL 1995, GOST R 23511-79, GOST R 50033-92
Thermoscreens Limited, St. Mary's Road, Nuneaton, Warwickshire CV11 5AU
Telephone: +44 (0) 2476 384 646 Fax: +44 (0) 2476 388 578 E-mail: [email protected] Web site: www.thermoscreens.com
All information within this brochure is for reference purposes only.
Products are manufactured under a continuous improvement process and details may change.
Certificate No FM 85224
Australia Austria Bahrain Belgium Brazil Bulgaria Canada Chile Cyprus Denmark Estonia Finland France Germany Hungary Iceland Italy KazakhstanKuwait Latvia Lithuania Malta Oman Poland Portugal Qatar Rep.of Ireland Romania Russia Slovenia Spain The Netherlands Turkey UAE UK
WORLDWIDE DISTRIBUTORS
A GROUP COMPANY
Registered in England no. 691333
HEAT PUMP RANGE
ENERGY RECOVERY AND TECHNOLOGY
The PHV DXE range of air curtains has been developed in a collaboration between Thermoscreens, the market leading manufacturer of high quality air solutions and the leading environmental control manufacturer Mitsubishi Electric.
Heat pumps are movers of heat energy and upgrade naturally occurring low temperature heat from the surrounding outdoor air into useful high temperature heat which can then be used to reduce the primary fuel consumption of mechanical equipment. As heat pumps require less that a third of the power of an equivalent direct electric air curtain, they are considerably cheaper to run.
The retro fi t of a heat pump is easy and not expensive. The heat pump unit is usually installed on the top of a building or on the facade. The air curtain is installed above the door opening as usual and connected to the
heat pump. The air curtain and heat pump is controlled via a Mitsubishi interface integrated in the air curtain. This allows a high degree of effi ciency and high COP’s up to 3.7.
Both Thermoscreens and Mitsubishi Electric are re-sponding to a growing market for highly effi cient equip-ment that delivers exceptional performance in the most energy effi cient way possible.
Heat pumps upgrade naturally occurring energy from the outdoor air via a refrigerant gas (R410A) and transmit this energy to an air curtain.
Outdoor air energy
Heating energy for air curtain
Electric energy for heat pump
Heat pump
HEAT PUMP RANGE
APPLICATIONThe range is available as either surface mounted or recessed models. The recommended maximum door height of an installation is 3.75m.
AIR CURTAINThe surface mounted PHV DXE range is manufactured in a contemporary design. The steel casing, including the removable front panel, is fi nished in standard RAL 9010. The recessed unit is designed with a combined inlet and outlet grille. Tangential fans provide a constant and comfortable air stream.
HEAT PUMPThe air curtain PHV DXE is equipped with a Mitsubishi Electric interface. This allows an easy connection to Mr. Slim Power Inverter and Zubadan Inverter heat pumps. The systems are aligned and allow optimal functioning.
EFFICIENCYThe independent BRE Institute ( Building Research Establishment,UK) analysed the effi ciency of the whole system. A COP of 3.7 was achieved. This can vary bet-ween 2.4 and 3.7 depending on the outdoor temperature and operating performance.
BENEFITS
Advanced modern technology Reduced running costs Reduced carbon emissions Signifi cant payback period Easy to install and maintain High energy effi ciency through inverter technology Allows open door policy
PHV DXE SURFACE MOUNTED
PHV DXE RECESSED RANGE
1 for units with electric heaters disabled, 240v power supply 1.8 amp load
2 for units with electric heaters disabled, 240v power supply 2.7 amp load
3,75
01,0 2,00,5 1,5
PH
V150
0DXE
NT
PH
V200
0DXE
NT
3,50
01,0 2,00,5 1,5
PH
V150
0DXE
R
PH
V200
0DXE
R
Models DimensionsL x D x H
(mm)
Supply(50Hz)
Heat Output (kW) COP
Loading(A)
Velocity(m/s)
Air volume (m3/h)
Weight (kg)
dB(A) @ 3m
PHV1500DXE NT HO 1746 x 377 x 255 400V-3P&N 50% 8.3100% 14.4
3.72.5 12.71 9.0 2600 60 60
PHV2000DXE NT LO 2296 x 377 x 255 400V-3P&N 50% 7.9100% 14.1
3.72.9 15.72 9.5 3300 78 61
PHV2000DXE NT HO 2296 x 377 x 255 400V-3P&N 50% 11.2100% 21.3
3.22.4 15.72 9.0 3130 80 61
Technical specification – Model PHV DXE R
Technical specification – Model PHV DXE
1 for units with electric heaters disabled, 240v power supply 1.8 amp load
2 for units with electric heaters disabled, 240v power supply 2.7 amp load.
Models DimensionsL x D x H
(mm)
Supply(50Hz)
Heat Output (kW) COP
Loading(A)
Velocity(m/s)
Air Volume (m3/h)
Weight (kg)
dB(A) @ 3m
PHV1500DXE R HO 1650 x 436 x 296 400V-3P&N 50% 8.3100% 14.4
3.72.5 12.71 9.0 2600 67 60
PHV2000DXE R LO 2240 x 436 x 296 400V-3P&N 50% 7.9100% 14.1
3.72.9 15.72 9.5 3300 85 61
PHV2000DXE R HO 2240 x 436 x 296 400V-3P&N 50% 11.2100% 21.3
3.22.4 15.72 9.0 3130 88 61
476 C
20-65mm
DECKENNIVEAU
A
B B
55
413
140
692
001
436
PHV DXE SURFACE MOUNTED
PHV DXE RECESSED RANGE
295
E E
D
C C
B
A
16836
255
377
100
M10 inserts x 6 mm
Hot Gas Refrigerant Connection
Electric Supply and Control Wiring Inlets
PHV1500DXE NT PHV2000DXE NT
A (mm) 1746 2296
B (mm) 1400 1896
C (mm) 700 948
D (mm) 1300 1824
E (mm) 650 912
PHV1500DXE R PHV2000DXE R
A (mm) 1650 2240
B (mm) 800 1095
C (mm) 1690 2290
Cut-Out in Ceiling:
Length (mm) 1655 2245
Width (mm) 445 445
www.thermoscreens.com
Liquid Line Refrigerant Connection
Alternative position for Electrical Supply an Control Wiring Inlets
250 mm
min.
for pipes
M10 inserts x 6 mm
Hot Gas Refrigerant Connection
Electric Supply and Control Wiring Inlets
Liquid Line Refrigerant Connection
CEILING LEVEL
HEAT PUMP MR.SLIM, POWER-/ZUBADAN- INVERTER
Models Dimensions LxWxH (mm)
Supply(50hz)
Loading A per phase Fuse
Comple-te pipe length
max. height
differenceConnections Communication
cable
Thermoscreens Mitsubishi Electric
PHV1500DXE HO
PUHZ-RP140YHA(Power Inverter) 950 x 330 x 1350 400V-3PN 6.37 16 75 30 fl . 10
s. 16 2 core
PUHZ-HRP125YHA(Zubadan Inverter) 943 x 330 x 1350 400V-3PN 4.91 16 75 30 fl . 10
s. 16 2 core
PHV2000DXE LO
PUHZ-RP140YHA(Power Inverter) 950 x 330 x 1350 400V-3PN 6.37 16 75 30 fl . 10
s. 16 2 core
PUHZ-HRP125YHA(Zubadan Inverter) 943 x 330 x 1350 400V-3PN 4.91 16 75 30 fl . 10
s. 16 2 core
PHV2000DXE HO PUHZ-RP200YHA2(Power Inverter) 950 x 330 + 30 x 1350 400V-3PN 8.8 32 120 30 fl . 10
s. 22 2 core
Technical Data- PUHZ range
CONTROL SYSTEM
Kommunikationsleitung
ThermoscreensPHV DXE
ThermoscreensBedieneinheit
Luftschleier An/AusHeizung An/AusHeizung Auto/Niedrig/Hoch
Mitsubishi ElectricMr. Slim
Connection cable
Air curtain On/Off
Heating On/OffHeating Auto/Low/High
Thermoscreens Control Unit
CONTROL OPTIONS
MANUAL CONTROLThe Thermoscreens air curtain have the option of a stand alone remote controller when the air curtain is not controlled by BEMS ( Building Energy Manage-ment System ).
This controller has the following functions
- 50% or 100%
- Ambient/heat switch
- Auto Mode ( to ensure consistent comfort levels are thermostatically maintained)
DIRTY FILTER INDICATORThermoscreens install a Dirty fi lter Indicator in every heat pump air curtain to indicate when the fi lter needs cleaning. The fi lter indicator schedule is based on fan operating hours and helps the customer to maintain and service the air curtain appropriately.
ADDITIONAL OPTIONS
Standard colour RAL 9010, other RAL colours available on request
Additional electrical heating for defrost period