48
Heating and Ventilation Product Catalogue 2019 Freedom Heat Pumps - www.freedomhp.co.uk

Heating and Ventilation Product Catalogue Info/Mitsubishi/2019_Heating... · EHPX-VM2C FTC5 Packaged Hydrobox for Ecodan Monobloc Units PUHZ-SW Split Air Source Heat Pumps EHST20(D)(C)-MHCW

  • Upload
    others

  • View
    19

  • Download
    0

Embed Size (px)

Citation preview

Page 1: Heating and Ventilation Product Catalogue Info/Mitsubishi/2019_Heating... · EHPX-VM2C FTC5 Packaged Hydrobox for Ecodan Monobloc Units PUHZ-SW Split Air Source Heat Pumps EHST20(D)(C)-MHCW

Heating and VentilationProduct Catalogue2019

Freedom Heat Pumps - www.freedomhp.co.uk

Page 2: Heating and Ventilation Product Catalogue Info/Mitsubishi/2019_Heating... · EHPX-VM2C FTC5 Packaged Hydrobox for Ecodan Monobloc Units PUHZ-SW Split Air Source Heat Pumps EHST20(D)(C)-MHCW

Ecodan Domestic Renewable Heating Systems

PUHZ-W-VAA Monobloc Standalone Ultra Quiet Air Source Heat Pumps

PUHZ-(H)W Monobloc Standalone Air Source Heat Pumps

QUHZ-W40VA / EHPT20Q-VM2EA Monobloc Air Source Heat Pump with Thermal Store

EHPT20X-MHCW FTC5 Packaged Cylinder for Ecodan Monobloc Units

EHPT15-17X-UKHLCW FTC5 Pre-plumbed Slimline Cylinders for Ecodan Monobloc Units

EHPT15-30X-UKHCW FTC5 Pre-plumbed Standard Cylinders for Ecodan Monobloc Units

EHPT21-30X-UKHSCW FTC5 Pre-plumbed Solar Cylinders for Ecodan Monobloc Units

EHPX-VM2C FTC5 Packaged Hydrobox for Ecodan Monobloc Units

PUHZ-SW Split Air Source Heat Pumps

EHST20(D)(C)-MHCW FTC5 Cylinders for Ecodan Split Units

EHS(D)(C)-MEC FTC5 Hydroboxes for Ecodan Split Units

FTC2B Flow Temperature Controller for use with Ecodan Monobloc Units and Third Party BEMS

i-LIFE2 Slim 80-170 DLMV Fan Assisted Radiator

MELCloud Wi-Fi Control

Energy Monitoring Packs

Accessories / Optional Extras

Ecodan Commercial Renewable Heating Systems

CAHV Monobloc Air Source Heat Pump

CRHV Monobloc Ground / Water Source Heat Pump

Accessories / Optional Extras

VL-50S2/ES2/SR2 Wall Mounted Lossnay

VL-100(E)U5-E Wall Mounted Lossnay

VL-220CZGV-EB Residential / Light Commercial Lossnay

8

10

12

14

16

18

20

22

24

26

28

30

31

32

34

35

36

38

40

42

44

46

Contents Heating

Ventilation

Freedom Heat Pumps - www.freedomhp.co.uk

Page 3: Heating and Ventilation Product Catalogue Info/Mitsubishi/2019_Heating... · EHPX-VM2C FTC5 Packaged Hydrobox for Ecodan Monobloc Units PUHZ-SW Split Air Source Heat Pumps EHST20(D)(C)-MHCW

Heating

Freedom Heat Pumps - www.freedomhp.co.uk

Page 4: Heating and Ventilation Product Catalogue Info/Mitsubishi/2019_Heating... · EHPX-VM2C FTC5 Packaged Hydrobox for Ecodan Monobloc Units PUHZ-SW Split Air Source Heat Pumps EHST20(D)(C)-MHCW

Page 4 Heating and Ventilation Product Catalogue 2019

Increasing energy bills, the need to reduce carbon emissions and the raft of challenging legislation are driving the demand for alternative forms ofheating to improve energy efficiency.

As a market leader in both commercial and domestic renewable solutions, Mitsubishi Electric is a pioneer in the development of heat pump technology. Heat pumps have been used around the world for decades and Mitsubishi Electric has refined thistechnology to produce Ecodan - one of the most advanced, efficient heating systems available today.

The award winning Ecodan heat pump range is suitable for both small and large projects and delivers effective, low carbonheating and hot water. Ecodan heat pumps provide a simple, renewable solution that rivals traditional heating systems.

MELCloud is a Cloud based solution for controlling your Mitsubishi Electric Ecodanheating systems either locally or remotely by PC, Mac, Tablet or Smartphone via the Internet.

Helps achieve renewable energy targets, reduce annual running costs and CO2 emissions

Systems from 4kW to 960kW, easy to design, install and maintain

MCS approved

From small flats to large detached houses, office blocks, schools and

community heating schemes, Ecodan is the ideal choice to provide

reliable space heating and hot water all year round.

Certificate Number: MCS HP0002Product Type: Heat PumpsProduct Reference: PUHZ-W50VHA2(-BS), PUHZ-W85VHA2(-BS)PUHZ-W112VHA(-BS), PUHZ-HW140VHA2(-BS)/YHA2(-BS)QUHZ-W40VA, PUHZ-SW50VKA-BS, PUHZ-SW75VHA-BSPUHZ-SW120VHA-BS, CAHV-P500YA-HPB

Freedom Heat Pumps - www.freedomhp.co.uk

Page 5: Heating and Ventilation Product Catalogue Info/Mitsubishi/2019_Heating... · EHPX-VM2C FTC5 Packaged Hydrobox for Ecodan Monobloc Units PUHZ-SW Split Air Source Heat Pumps EHST20(D)(C)-MHCW

Page 5 Heating and Ventilation Product Catalogue 2019

Ecodan heat pumps harvest, upgrade and move heat from one location to another.

To achieve this the vapour compression cycle is used, which has the ability to take low temperature renewable heat from the environment and raise it to usable temperaturescapable of handling the space and water heating loads required in buildings.

How Ecodan air source heat pumps work

At the beginning of the first phase the refrigerant is a cold low pressure liquid

1. The refrigerant passes into the evaporator and heat energy from the outside air passes over the evaporator causing the refrigerant to increase in pressure and change to a warm vapour

2. This warm vapour then enters the compressor where its temperature increases as a result of the compression process and turns into a hot gas

3. The hot refrigerant gas is then condensed as it passes across one side of a plate heat exchanger. The heat is transferred to thecooler side (water side) of the heat exchanger, and this is transferredvia the primary water circuit to heat up the water cylinder insidethe property. As the temperature of the refrigerant decreases the state changes from a gas back to a cool vapour

4. Despite dropping in temperature, the cool vapour still has a high pressure and to reduce this pressure the vapour passes throughan expansion valve. This causes the pressure to drop and thetemperature lowers, returning the refrigerant to its initial stateof cool low pressure liquid.

This process is repeated

It is only the refrigerant that passes through this cycle; the water is heated as it travels through the plate heat exchanger.The heat energy from the refrigerant passes through the plate heat exchanger to the cooler water which increases in temperature. This heated water enters the building heating circuit and can also be used to provide sanitary hot water via a hot water cylinder.

3.2kW

2.2kW

*

*As independently tested by BSRIA based upon BSEN14511 Part 3 standard rating conditions.Due to the method of operation, the performance of heat pumps will vary based upon thetemperature of the heat source and the requirements of the heat delivered. The BSEN14511testing relates to the heat pump performance only and not the entire heating system.

The vapour compression cycle

Freedom Heat Pumps - www.freedomhp.co.uk

Page 6: Heating and Ventilation Product Catalogue Info/Mitsubishi/2019_Heating... · EHPX-VM2C FTC5 Packaged Hydrobox for Ecodan Monobloc Units PUHZ-SW Split Air Source Heat Pumps EHST20(D)(C)-MHCW

Page 6 Heating and Ventilation Product Catalogue 2019

The complete range of Ecodan heating products has received full accreditation for the Government’s Microgeneration Certification Scheme (MCS).

In addition to certifying heating products the MCS process also looks at the companies installing this type ofequipment so that customers can take real confidence that they will get the performance and service expected. MCS is designed to evaluate products and installers against criteria for microgeneration technologies, thereby providing greater consumer protection. An MCS approved product, such as Ecodan, installed by an MCS approved installer is a requirement to apply for the Government’s Renewable Heat Incentive (RHI).

Microgeneration Certification Scheme

The PCDB, formerly known as SAP Appendix Q, allows you to enter performance data specific to Ecodan rather than using the defaultair source heat pump data in SAP. This enables a higher efficiency to be shown within the SAP calculations for the property.

Product Characteristics Database, PCDB

Ecodan provides a proven, efficient way of heating buildings. The Government will now pay for the generation of renewable heat through theRenewable Heat Incentive (RHI). This has been designed to level the playing field between the cost of renewable and traditional fossil fuel systems.Switching to heating systems that use eligible energy services can help the UK reduce its carbon emissions and meet its renewable energy targets.

Renewable Heat Incentive, RHI

Ecodan is compliant with the Energy Related Products Directive or ErP, which is a key part of the European Union’s drive to encourage businesses and consumers to use more energy efficient products.

The Ecodan heat pump range has an energy label of A++

The Energy Related Products Directive (ErP)

The Ecodan range was the first air source heat pump in the UK to receive the official backing of the Noise Abatement Society which awarded it the ‘Quiet Mark’ of approval.

Quiet Mark

FTC5 Controller

Mitsubishi Electric’s fifth generationcontroller (FTC5) includes intelligentroom temperature control as standard.

This together with advanced weather compensationensures the system delivers efficient, comfortableheating regardless of the season. FTC5 now alsoincludes energy monitoring showing consumed and produced energy.

Freedom Heat Pumps - www.freedomhp.co.uk

Page 7: Heating and Ventilation Product Catalogue Info/Mitsubishi/2019_Heating... · EHPX-VM2C FTC5 Packaged Hydrobox for Ecodan Monobloc Units PUHZ-SW Split Air Source Heat Pumps EHST20(D)(C)-MHCW

Page 7 Heating and Ventilation Product Catalogue 2019

Homeowner Help - Support and Videos

Ecodan Sales Tools

Ecodan Selection Tool - Renewable Heat Incentive (RHI) Calculator

These videos were developed to increase understanding amongsthomeowners on how to get the best out of their Ecodan heating system, and uses clear animations to show how to operate the systems controller.

Offering guidance through video tutorials, these are a useful tool for installers when demonstrating how Ecodan works, as it provides easy access to simple but detailed information on how to operate, programme and manage the system. The site also includes a very useful FAQ section which has been designed to increase the understanding of how air source heat pumps work.

Please visit the website: les.mitsubishielectric.co.uk/help-and-support

The Ecodan Selection Tool allows end users, consultants, contractors or anyone else with an interest in heat pumps to get an insight into what this technology could deliver to your building.

Whether your project is a single domestic dwelling or a large commercial project, the application is designed to direct you towards the right solution, whilst personalising the information for you.

So for example, as a homeowner we have chosen to supply you with case studies and application information, but for an installer you would want to know more technical information about the heat pump itself and have the ability to design an Ecodan system to MIS3005 standards. The aim of the tool is to deliver a personalised bespoke equipment selectionfor your project; allowing you to make a decision about progressing to the next stage of design.

Please visit the website:ecodanselectiontool.heating.mitsubishielectric.co.uk

Freedom Heat Pumps - www.freedomhp.co.uk

Page 8: Heating and Ventilation Product Catalogue Info/Mitsubishi/2019_Heating... · EHPX-VM2C FTC5 Packaged Hydrobox for Ecodan Monobloc Units PUHZ-SW Split Air Source Heat Pumps EHST20(D)(C)-MHCW

Page 8 Heating and Ventilation Product Catalogue 2019

PUHZ-W-VAAMonobloc Standalone

Ultra Quiet Air Source

Heat Pumps

Our range of ultra quiet AA chassis Ecodan monobloc air source heat pumps include 8.5 and 11.2kW sizes.

The innovative, stylish and compact single fan outdoor unit utilises advanced technologies to deliver improved efficiencies.Designed to satisfy current domestic premises permitted development standards (MCS020), the market leading low noiselevels virtually eliminate the need for planning permission and maximises installation options.

Self-contained unit, only requiring water and electric connections

No need for gas supply, flues or ventilation

Low maintenance and ultra quiet operation

Operates with outside temperatures as low as -20ºC

Optimised low ambient defrost control and operation

Hybrid function, for use with conventional boilers

Energy monitoring as standard

Key Features

A++

137%

3.50

A++

171%

4.35

A

104%

8.3

2.86

2.90

-20 ~ +35°C

45

58

28

25.8

16.1

1050

480

1020

97

220-240v, 50Hz

Single

9.1 [22.0]

25

2.4/5.01

A++

133%

3.40

A++

170%

4.34

A

100%

11.0

3.73

2.95

-20 ~ +35°C

47

60

28

32.1

24.4

1050

480

1020

118

220-240v, 50Hz

Single

10.9 [28.0]

32

3.3/6.89

HEAT PUMP SPACE

HEATER - 55˚C

HEAT PUMP SPACE

HEATER - 35˚C

HEAT PUMP COMBINATION

HEATER - Large Profile*1

HEATING*2

(A-3/W35)

OPERATING AMBIENT TEMPERATURE (°C DB)

SOUND DATA*3

WATER DATA

DIMENSIONS (mm)*7

WEIGHT (kg)

ELECTRICAL DATA

REFRIGERANT CHARGE (kg)

/ CO2 EQUIVALENT (t)

ErP Ratingɳs

SCOP

ErP Ratingɳs

SCOP

ErP Ratingɳwh

Capacity (kW)

Power Input (kW)

COP

Pressure Level at 1m (dBA)

Power Level (dBA)*4

Pipework Size (mm)

Flow Rate (l/min)

Water Pressure Drop (kPa)

Width

Depth

Height

Electrical Supply

Phase

Nominal Running Current [MAX] (A)

Fuse Rating - MCB Sizes (A)*6

R410A (GWP 2088)

OUTdOOr UniT PUHZ-W85VAA(-BS) PUHZ-W112VAA(-BS)

*1 Combination with EHPT20X-MHCW Cylinder*2 Under normal heating conditions at outdoor temp: -3°CDB / -4°CWB, outlet water temp 35°C, inlet water temp 30°C.*3 Under normal heating conditions at outdoor temp: 7°CDB / 6°CWB, outlet water temp 55°C, inlet water temp 47°C as tested to BS EN14511.*4 Sound power level tested to BS EN12102. *5 MCB Sizes BS EN60898-2 & BS EN60947-2. *6 Flow Temperature Controller (FTC) for standalone systems PAC-IF062B-E Dimensions WxDxH (mm) - 520x150x450

ɳs is the seasonal space heating energy efficiency (SSHEE) ɳwh is the water heating energy efficiency

Freedom Heat Pumps - www.freedomhp.co.uk

Page 9: Heating and Ventilation Product Catalogue Info/Mitsubishi/2019_Heating... · EHPX-VM2C FTC5 Packaged Hydrobox for Ecodan Monobloc Units PUHZ-SW Split Air Source Heat Pumps EHST20(D)(C)-MHCW

Page 9 Heating and Ventilation Product Catalogue 2019

802

1020

3052

8

3631050

Upper View Front View

480

225 600

75

520

567

28 53

(19)

Product Dimensions PUHZ-W85 / 112VAA(-BS)

Freedom Heat Pumps - www.freedomhp.co.uk

Page 10: Heating and Ventilation Product Catalogue Info/Mitsubishi/2019_Heating... · EHPX-VM2C FTC5 Packaged Hydrobox for Ecodan Monobloc Units PUHZ-SW Split Air Source Heat Pumps EHST20(D)(C)-MHCW

Page 10 Heating and Ventilation Product Catalogue 2019

PUHZ-(H)WMonobloc Standalone

Air Source Heat Pumps

Our range of Ecodan monobloc air source heat pumps includes 5 and 14kW sizes.

Now with the ability to cascade up to six units of the same output, Ecodan monobloc systems offer a capacity rangefrom 5 through to 84kW. Designed to suit a wide number of applications, these models offer a viable solution for thevarying requirements that domestic and small commercial applications demand.

Certificate Number: MCS HP0002

Product Type: Heat Pumps

Product Reference:

PUHZ-W50VHA2(-BS),

PUHZ-HW140VHA2/YHA2(-BS)

Self-contained unit, only requiring water and electric connections

No need for gas supply, flues or ventilation

Low maintenance and quiet operation

Operates with outside temperatures as low as -25ºC

Hybrid function, for use with conventional boilers

Energy monitoring as standard

Key Features

A++

127%

3.25

A++

162%

4.12

A

99%

4.8

1.63

2.95

-15 ~ +35°C

45

40

22

14.3

12

950

330+30*5

740

64

220-240v, 50Hz

Single

5.4 [13]

16

1.7 / 3.5

A++

126%

3.22

A++

157%

3.99

A

96%

14.0

4.81

2.91

-25 ~ +35°C

53

46

28

40.1

9

1020

330+30*5

1350

134

220-240v, 50Hz

Single

14.9 [35]

40

4.3 / 9.0

A++

126%

3.22

A++

157%

3.99

A

96%

14.0

4.81

2.91

-25 ~ +35°C

53

46

28

40.1

9

1020

330+30*5

1350

148

380-415v, 50Hz

3

5.1 [13]

16

4.3 / 9.0

HEAT PUMP SPACE

HEATER - 55˚C

HEAT PUMP SPACE

HEATER - 35˚C

HEAT PUMP COMBINATIONHEATER - Large Profile*1

HEATING*2

(A-3/W35)

OPERATING AMBIENT TEMPERATURE (°C DB)

SOUND PRESSURE LEVEL AT 1M (dBA)*3*4

LOW NOISE MODE (dBA)*3

WATER DATA

DIMENSIONS (mm)*7

WEIGHT (kg)

ELECTRICAL DATA

REFRIGERANT CHARGE (kg) / CO2 EQUIVALENT (t)

ErP Ratingɳs

SCOP

ErP Ratingɳs

SCOP

ErP Ratingɳwh

Capacity (kW)

Power Input (kW)

COP

Pipework Size (mm)

Flow Rate (l/min)

Water Pressure Drop (kPa)

Width

Depth

Height

Electrical Supply

Phase

Nominal Running Current [MAX] (A)

Fuse Rating - MCB Sizes (A)*6

R410A (GWP 2088)

OUTdOOr UniT PUHZ-W50VHA2(-BS) PUHZ-HW140VHA2(-BS) PUHZ-HW140YHA2(-BS)

*1 Combination with EHPT20X-MHCW Cylinder*2 Under normal heating conditions at outdoor temp: -3°CDB / -4°CWB, outlet water temp 35°C, inlet water temp 30°C.*3 Under normal heating conditions at outdoor temp: 7°CDB / 6°CWB, outlet water temp 35°C, inlet water temp 30°C as tested to BS EN14511.*4 Sound power level of the PUHZ-W50VHA2 is 61dBA, PUHZ-HW140VHA2 is 65.5dBA, PUHZ-HW140YHA2 is 67.5dBA. Tested to BS EN12102.*5 Grille. *6 MCB Sizes BS EN60898-2 & BS EN60947-2. *7 Flow Temperature Controller (FTC) for standalone systems PAC-IF062B-E Dimensions WxDxH (mm) - 520x150x450

ɳs is the seasonal space heating energy efficiency (SSHEE) ɳwh is the water heating energy efficiency

Freedom Heat Pumps - www.freedomhp.co.uk

Page 11: Heating and Ventilation Product Catalogue Info/Mitsubishi/2019_Heating... · EHPX-VM2C FTC5 Packaged Hydrobox for Ecodan Monobloc Units PUHZ-SW Split Air Source Heat Pumps EHST20(D)(C)-MHCW

Page 11 Heating and Ventilation Product Catalogue 2019

Product Dimensions PUHZ-(H)W140VHA(2)/YHA2(-BS)Product Dimensions PUHZ-W50VHA2(-BS)

Upper View

Front View

Upper View

Front View

Freedom Heat Pumps - www.freedomhp.co.uk

Page 12: Heating and Ventilation Product Catalogue Info/Mitsubishi/2019_Heating... · EHPX-VM2C FTC5 Packaged Hydrobox for Ecodan Monobloc Units PUHZ-SW Split Air Source Heat Pumps EHST20(D)(C)-MHCW

Page 12 Heating and Ventilation Product Catalogue 2019

200

40-70°C

25-60°C

DHW and 1 Heating Zone

(2 Zone capability with 3rd party 2-port valves)

0 ~ +35°C (RH<80%)

30

40

Grundfos Solar PML 25-145 180

Grundfos Solar PML 25-145 180

22 / 22

18

0.1 (1)

0.3 (3) - 2 No. devices

Min. flow 1.3 L/min

85°C

595

680

1600

77 / 283

220-240v, 50Hz

Single

15

20

PAR-WT50-E Controller and PAR-WR51-E Receiver

NOMINAL THERMAL STORE WATER VOLUME (LITRES)

WATER TEMPERATURE RANGE DHW Mode (°C)

Space Heating Mode (°C)

MECHANICAL ZONES

OPERATING AMBIENT TEMPERATURE (°C DB)

SOUND PRESSURE LEVEL AT 1M (dBA)

SOUND POWER LEVEL (dBA)*4

WATER DATA Primary Pump

Sanitary Hot Water Pump

Connection Size (mm) Heating / DHW

Primary Expansion Vessel (Litres)

Charge Pressure (MPa (Bar))

WATER SAFETY DEVICES Pressure relief valve (Mpa (Bar))

Flow sensor (supplied)

Manual reset thermostat

DIMENSIONS (mm) Width

Depth

Height

WEIGHT EMPTY / FULL (kg)

ELECTRICAL DATA Electrical Supply

Phase

Maximum Running Current (A)

Fuse Rating - MCB Sizes (A)*6

OPTIONAL SIMPLIFIED WIRELESS ROOM THERMOSTAT AND WIRELESS RECEIVER

A+

117%

2.90

A

129%

3.00

4.32

2.18

1.98

-15 ~ +35°C

43

53

15

3 to 8

5

15

809+70*5

300+20*5

715

57

Powered from indoor unit

1.12 / 0.001

HEAT PUMP COMBINATION

HEATER - 55ºC

HEAT PUMP COMBINATION

HEATER - Large Profile*1

HEATING*2

(A-3/W55)

OPERATING AMBIENT TEMPERATURE (°C DB)

SOUND PRESSURE LEVEL AT 1M (dBA)*3

SOUND  POWER  LEVEL (dBA)*4

WATER DATA

DISTANCE BETWEEN OUTDOOR

UNIT AND THERMAL STORE

(M) DIMENSIONS (mm)

DIMENSIONS

WEIGHT (kg)

ELECTRICAL DATA

REFRIGERANT CHARGE (kg) / CO2 EQUIVALENT (t)

ErP Rating

ɳs

SCOP

ErP Rating

ɳwh

COP

Capacity (kW)

Power Input (kW)

COP

Pipework Size (mm)

Flow Rate (l/min)

Height Difference

Piping Length

Width

Depth

Height

Refrigerant R744

QUHZ-W40VA /EHPT20Q-VM2EAMonobloc Air Source Heat Pump

With Thermal Store

The Ecodan QUHZ is the ideal solution for new build homes where strict building regulations drive down the space heating demand, making the production of hot water the dominant load.

The Ecodan QUHZ operates with a market leading low noise output and built in energy monitoring as standard.The thermal store has been specifically designed to work with this system, giving high hot water output without the need to pasteurise the water.

Certificate Number: MCS HP0002

Product Type: Heat Pumps

Product Reference: QUHZ-W40VA

OUTdOOr UniT QUHZ-W40VA THErMAL STOrE EHPT20Q-VM2EA

*1 Combination with EHPT20Q-VM2EA Thermal Store.*2 Under normal heating conditions at outdoor temp: -3°CDB / -4°CWB, outlet water temp 55°C, inlet water temp 47°C.*3 Under normal heating conditions at outdoor temp: 7°CDB / 6°CWB, outlet water temp 55°C, inlet water temp 47°C as tested to BS EN14511.*4 Sound power level tested to BS EN12102.*5 Grille or pipe cover.*6 MCB Sizes BS EN60898-2 & BS EN60947-2.

ɳs is the seasonal space heating energy efficiency (SSHEE) ɳwh is the water heating energy efficiency

High efficiency hot water heating performance

Class leading low noise operation

Energy monitoring as standard

No stored water, no risk of legionella

Key Features

Freedom Heat Pumps - www.freedomhp.co.uk

Page 13: Heating and Ventilation Product Catalogue Info/Mitsubishi/2019_Heating... · EHPX-VM2C FTC5 Packaged Hydrobox for Ecodan Monobloc Units PUHZ-SW Split Air Source Heat Pumps EHST20(D)(C)-MHCW

Page 13Heating and Ventilation Product Catalogue 2019

Product Dimensions QUHZ-W40VA Product Dimensions EHPT20Q-VM2EA

Upper View

Side View

Front View Left View

Upper View

Front View Right View Rear View

22 mm/Compression

22 mm/Compression

22 mm/Compression

22 mm/Compression

22 mm/Compression

22 mm/Compression

DHW outlet connection

Cold water inlet connection

Space heating return connection

Space heating flow connection

Flow from heat pump connection

Return to heat pump connection

A

B

C

D

E

F

Letter Pipe Description Connection size/type

Freedom Heat Pumps - www.freedomhp.co.uk

Page 14: Heating and Ventilation Product Catalogue Info/Mitsubishi/2019_Heating... · EHPX-VM2C FTC5 Packaged Hydrobox for Ecodan Monobloc Units PUHZ-SW Split Air Source Heat Pumps EHST20(D)(C)-MHCW

Page 14 Heating and Ventilation Product Catalogue 2019

The packaged cylinder offers a highly adaptable heating solution for retrofit or new build.

Designed specifically to integrate with the Ecodan monobloc air source heat pump range, the cylinder provides improvedperformance and faster heat up times through the use of plate heat exchanger technology. Fast commissioning via an SD card and energy monitoring functions are now included.

Optional 2-zone energy efficient space heating control

Pre-plumbed and wired for faster installation

Hybrid function, for use with conventional boilers

Energy monitoring as standard

Key Features

EHPT20X-MHCWFTC5 Packaged Cylinder for

Ecodan Monobloc Units

FTC5 Controller

Mitsubishi Electric’s fifth generation controller(FTC5) includes intelligent room temperaturecontrol as standard. This together withadvanced weather compensation ensures the system delivers efficient, comfortableheating regardless of the season. FTC5 now also includes energy monitoring showing consumed and produced energy.

*1 MCB Sizes BS EN60898-2 & BS EN60947-2 *2 Optional 2 zone accessory pack available

CYLindEr EHPT20X-MHCW

NOMINAL HOT WATER VOLUME (LITRES)

HEAT PUMP COMBINATION HEATER - Large Profile (with PUHZ-W85VHA2)OPERATING AMBIENT TEMPERATURE (°C DB)

SOUND PRESSURE LEVEL AT 1M (dBA)

WATER DATA

WATER SAFETY DEVICES

DIMENSIONS (mm)

WEIGHT EMPTY / FULL (kg)ELECTRICAL DATA

ErP Rating

Flow Rate (l/min) W50 - W85 - W112 - HW140Primary PumpSanitary Hot Water PumpConnection Size (mm) Heating / DHWPrimary Expansion Vessel (Litres)Charge Pressure (MPa (Bar))Control Thermistor (°C)Pressure Relief Valve (MPa (Bar))Flow Sensor (minimum flow 5L/min)Control Thermistor (°C)Temp and Pressure Relief Valve (°C)/ (MPa (Bar))WidthDepthHeight

Electrical Supply

Phase Fuse Rating - MCB Sizes (A)*1

Electrical SupplyPhase

Capacity (kW)Max Running Current (A)

Fuse Rating - MCB Sizes (A)*1

Water Circuit

DHW Cylinder

Control Board -optionally powered

by outdoor unit

Immersion Heater

200A

0 ~ +35°C (RH<80%)28

14.3 - 25.8 - 32.1 - 40.1Grundfos UPM2 15 70 - 130

Grundfos UPSO 15-60 130 CIL228 / 22

120.1 (1)1 - 800.3 (3)

Supplied40-70

90 / 0.7 (7)595680

160098 / 307

220-240v, 50HzSingle

10

220-240v, 50Hz

Single

3

13

16

OPTIONAL SIMPLIFIED WIRELESS ROOM THERMOSTAT AND WIRELESS RECEIVER PAR-WT50-E Controller and PAR-WR51-E Receiver

MECHANICAL ZONES DHW and 1 Heating Zone*2

Freedom Heat Pumps - www.freedomhp.co.uk

Page 15: Heating and Ventilation Product Catalogue Info/Mitsubishi/2019_Heating... · EHPX-VM2C FTC5 Packaged Hydrobox for Ecodan Monobloc Units PUHZ-SW Split Air Source Heat Pumps EHST20(D)(C)-MHCW

Page 15 Heating and Ventilation Product Catalogue 2019

Product Dimensions EHPT20X-MHCW

Front View Right ViewLeft View

DHW outlet connection

Cold water inlet connection

Space heating return connection

Space heating flow connection

Flow from heat pump connection

Return to heat pump connection

Electrical cable inlets

22mm/Compression

22mm/Compression

28mm/Compression

28mm/Compression

28mm/Compression

28mm/Compression

A

B

C

D

E

F

G

Pipe description Connection Size/TypeLetter

Upper View

Freedom Heat Pumps - www.freedomhp.co.uk

Page 16: Heating and Ventilation Product Catalogue Info/Mitsubishi/2019_Heating... · EHPX-VM2C FTC5 Packaged Hydrobox for Ecodan Monobloc Units PUHZ-SW Split Air Source Heat Pumps EHST20(D)(C)-MHCW

Page 16 Heating and Ventilation Product Catalogue 2019

The pre-plumbed slimline cylinder comes complete with integrated hydraulic components and advanced controls.

Designed to minimise floor space and footprint whilst still offering optimum performance, the cylinder completely integrates with theEcodan monobloc air source heat pump range. The slimline cylinder provides improved performance and faster heat up times through the use of plate heat exchanger technology. Fast commissioning via an SD card and energy monitoring functions are now included.EHPT15-17X-

UKHLCW

FTC5 Pre-plumbed SlimlineCylinders for EcodanMonobloc Units

*1 MCB Sizes BS EN60898-2 & BS EN60947-2 *2 Optional 2 zone accessory pack available

CYLindEr EHPT15X-UKHLCW EHPT17X-UKHLCWNOMINAL HOT WATER VOLUME (LITRES) 150 170

ErP RATING C C

HEAT LOSS (kWh/24hrs) 1.45 1.63

HEAT LOSS (W) 60.4 67.9

WATER Flow Rate (l/min) W50 - W85 - W112

Primary Pump 2 x Grundfos UPS2 15-60 2 x Grundfos UPS2 15-60

Sanitary Hot Water Pump Grundfos UPSO 15-60 CIL2 Grundfos UPSO 15-60 CIL2

Connection Size (mm) Heating / DHW (mm) 22 22

Primary Expansion Vessel (Litres) 12 18

Charge Pressure (MPa (Bar)) 0.35 (3.5) 0.35 (3.5)

WATER SAFETY Water Circuit Control Thermistor (°C) 1 - 80 1 - 80

DEVICES Pressure Relief Valve (MPa (Bar)) 0.3 (3) 0.3 (3)

Expansion Relief Valve (Cold) 0.8 (8) 0.8 (8)

DHW Cylinder Control Thermistor 40-70 40-70

High Limit Stat (°C) Mechanical 80 Mechanical 80

Temp and Pressure Relief Valve (°C) / (MPa (Bar)) 90 / 1.0 (10) 90 / 1.0 (10)

DIMENSIONS (mm) Width 600 600

Depth 595 595

Height 1495 1669

WEIGHT EMPTY / FULL (kg) 54 / 204 60 / 230

CYLINDER MATERIAL Cylinder Cylinder Material Stainless Steel Stainless Steel

Insulation Insulation Type CFC / HCFC-free flame-retardant expanded Polyurethane

Insulation Thickness (mm) 50 50

Standing Heat Loss (kWh/24hrs) 1.45 1.63

GWP of Insulation 3.1 3.1

ODP of Insulation 0 0

ELECTRICAL DATA Control Board Electrical Supply 220-240v, 50Hz 220-240v, 50Hz

Phase Single Single

Fuse Rating - MCB Sizes (A)*1 10 10

Electrical Supply 220-240v, 50Hz 220-240v, 50Hz

Phase Single Single

Capacity (kW) 3 3

Max Running Current (A) 13 13

Fuse Rating - MCB Sizes (A)*1 16 16

MECHANICAL ZONES DHW and 1 Heating Zone*2 DHW and 1 Heating Zone*2

OPTIONAL SIMPLIFIED WIRELESS ROOM THERMOSTAT AND WIRELESS RECEIVER PAR-WT50-E Controller and PAR-WR51-E Receiver

optionally powered byoutdoor unit

Immersion Heater

14.3 - 25.8 - 32.1

Optional 2-zone energy efficient space heating control

Pre-plumbed and wired for faster installation

Hybrid function, for use with conventional boilers

Energy monitoring as standard

Key Features FTC5 Controller

Mitsubishi Electric’s fifth generation controller(FTC5) includes intelligent room temperaturecontrol as standard. This together withadvanced weather compensation ensures the system delivers efficient, comfortableheating regardless of the season. FTC5 now also includes energy monitoring showing consumed and produced energy.

Freedom Heat Pumps - www.freedomhp.co.uk

Page 17: Heating and Ventilation Product Catalogue Info/Mitsubishi/2019_Heating... · EHPX-VM2C FTC5 Packaged Hydrobox for Ecodan Monobloc Units PUHZ-SW Split Air Source Heat Pumps EHST20(D)(C)-MHCW

Page 17 Heating and Ventilation Product Catalogue 2019

Product Dimensions EHPT15-17X-UKHLCW

Upper ViewFront View Side View

*All dimensions in mm

EHPT15X-UKHLCW

EHPT17X-UKHLCW

Overall HeightModel

1495

1669

Freedom Heat Pumps - www.freedomhp.co.uk

Page 18: Heating and Ventilation Product Catalogue Info/Mitsubishi/2019_Heating... · EHPX-VM2C FTC5 Packaged Hydrobox for Ecodan Monobloc Units PUHZ-SW Split Air Source Heat Pumps EHST20(D)(C)-MHCW

Page 18 Heating and Ventilation Product Catalogue 2019

The pre-plumbed standard cylinder comes complete with integrated hydraulic components and advanced controls.

Designed to integrate with the Ecodan monobloc air source heat pump range, the standard cylinder provides improved performance and faster heat up times through the use of plate heat exchanger technology. Fast commissioning via an SD card and energy monitoringfunctions are now included.EHPT15-30X

-UKHCW

FTC5 Pre-plumbed Standard Cylinders for Ecodan Monobloc Units

*1 MCB Sizes BS EN60898-2 & BS EN60947-2 *2 Optional 2 zone accessory pack available

CYLindEr EHPT15X-UKHCW EHPT17X-UKHCW EHPT21X-UKHCW EHPT25X-UKHCW EHPT30X-UKHCW150

B

1.19

49.6

22

12

0.35 (3.5)

1 - 80

0.3 (3)

0.8 (8)

40-70

Mechanical 80

90 / 1.0 (10)

712

691

1113

56 / 206

Stainless Steel

60

1.19

3.1

0

220-240v, 50Hz

Single

10

220-240v, 50Hz

Single

3

13

16

170

B

1.32

55.0

22

18

0.35 (3.5)

1 - 80

0.3 (3)

0.8 (8)

40-70

Mechanical 80

90 / 1.0 (10)

712

691

1239

62 / 232

Stainless Steel

60

1.32

3.1

0

220-240v, 50Hz

Single

10

220-240v, 50Hz

Single

3

13

16

210

C

1.57

65.4

22

18

0.35 (3.5)

1 - 80

0.3 (3)

0.8 (8)

40-70

Mechanical 80

90 / 1.0 (10)

712

691

1491

69 / 279

Stainless Steel

60

1.57

3.1

0

220-240v, 50Hz

Single

10

220-240v, 50Hz

Single

3

13

16

250

C

1.67

69.6

22

24

0.35 (3.5)

1 - 80

0.3 (3)

0.8 (8)

40-70

Mechanical 80

90 / 1.0 (10)

712

691

1743

77 / 327

Stainless Steel

60

1.67

3.1

0

220-240v, 50Hz

Single

10

220-240v, 50Hz

Single

3

13

16

300

C

1.89

78.8

22

24

0.35 (3.5)

1 - 80

0.3 (3)

0.8 (8)

40-70

Mechanical 80

90 / 1.0 (10)

712

691

2057

87 / 387

Stainless Steel

60

1.89

3.1

0

220-240v, 50Hz

Single

10

220-240v, 50Hz

Single

3

13

16

NOMINAL HOT WATER VOLUME (LITRES)

ErP RATING

HEAT LOSS (kWh/24hrs)

HEAT LOSS (W)

WATER Flow Rate (l/min) W50 - W85 - W112 - HW140

Primary Pump

Sanitary Hot Water Pump

Connection Size (mm) Heating / DHW (mm)

Primary Expansion Vessel (Litres)

Charge Pressure (MPa (Bar))

WATER SAFETY Water Circuit Control Thermistor (°C)

DEVICES Pressure Relief Valve (MPa (Bar))

Expansion Relief Valve (Cold)

DHW Cylinder Control Thermistor

High Limit Stat (°C)

Temp and Pressure Relief Valve (°C) / (MPa (Bar))

DIMENSIONS (mm) Width

Depth

Height

WEIGHT EMPTY / FULL (kg)

CYLINDER MATERIAL Cylinder Cylinder Material

Insulation Insulation Type

Insulation Thickness (mm)

Standing Heat Loss (kWh/24hrs)

GWP of Insulation

ODP of Insulation

ELECTRICAL DATA Control Board Electrical Supply

Phase

Fuse Rating - MCB Sizes (A)*1

Electrical Supply

Phase

Capacity (kW)

Max Running Current (A)

Fuse Rating - MCB Sizes (A)*1

MECHANICAL ZONES

OPTIONAL SIMPLIFIED WIRELESS ROOM THERMOSTAT AND WIRELESS RECEIVER

optionally powered byoutdoor unit

Immersion Heater

14.3 - 25.8 - 32.1 - 40.1

2 x Grundfos UPS2 25-60

Grundfos UPSO 15-60 CIL2

CFC / HCFC-free flame-retardant expanded Polyurethane

DHW and 1 Heating Zone*2

PAR-WT50-E Controller and PAR-WR51-E Receiver

Optional 2-zone energy efficient space heating control

Pre-plumbed and wired for faster installation

Hybrid function, for use with conventional boilers

Energy monitoring as standard

Key Features FTC5 Controller

Mitsubishi Electric’s fifth generation controller(FTC5) includes intelligent room temperaturecontrol as standard. This together withadvanced weather compensation ensures the system delivers efficient, comfortableheating regardless of the season. FTC5 now also includes energy monitoring showing consumed and produced energy.

Freedom Heat Pumps - www.freedomhp.co.uk

Page 19: Heating and Ventilation Product Catalogue Info/Mitsubishi/2019_Heating... · EHPX-VM2C FTC5 Packaged Hydrobox for Ecodan Monobloc Units PUHZ-SW Split Air Source Heat Pumps EHST20(D)(C)-MHCW

Page 19 Heating and Ventilation Product Catalogue 2019

Product Dimensions EHPT15-30X-UKHCW

Front View Upper ViewSide View

*All dimensions in mm

EHPT15X-UKHCW

EHPT17X-UKHCW

EHPT21X-UKHCW

EHPT25X-UKHCW

EHPT30X-UKHCW

Overall HeightModel

1113

1239

1491

1743

2057

Freedom Heat Pumps - www.freedomhp.co.uk

Page 20: Heating and Ventilation Product Catalogue Info/Mitsubishi/2019_Heating... · EHPX-VM2C FTC5 Packaged Hydrobox for Ecodan Monobloc Units PUHZ-SW Split Air Source Heat Pumps EHST20(D)(C)-MHCW

Page 20 Heating and Ventilation Product Catalogue 2019

The pre-plumbed solar cylinder comes complete with integrated hydraulic components and advanced controls.

Designed to integrate with the Ecodan monobloc air source heat pump range, the solar cylinder provides improved performance andfaster heat up times through the use of plate heat exchanger technology. Fast commissioning via an SD card and energy monitoringfunctions are now included.EHPT21-30X

-UKHSCW

FTC5 Pre-plumbed SolarCylinders for Ecodan Monobloc Units

*1 MCB Sizes BS EN60898-2 & BS EN60947-2 *2 Optional 2 zone accessory pack available

CYLindEr EHPT21X-UKHSCW EHPT25X-UKHSCW EHPT30X-UKHSCW210

C

1.56

65.0

22

18

0.35 (3.5)

1 - 80

0.3 (3)

0.8 (8)

40-70

Mechanical 80

90 / 1.0 (10)

678

694

1497

74 / 284

Stainless Steel

60

1.56

3.1

0

220-240v, 50Hz

Single

10

220-240v, 50Hz

Single

3

13

16

250

C

1.63

67.9

22

24

0.35 (3.5)

1 - 80

0.3 (3)

0.8 (8)

40-70

Mechanical 80

90 / 1.0 (10)

678

694

1749

82 / 332

Stainless Steel

60

1.63

3.1

0

220-240v, 50Hz

Single

10

220-240v, 50Hz

Single

3

13

16

300

C

1.84

76.7

22

24

0.35 (3.5)

1 - 80

0.3 (3)

0.8 (8)

40-70

Mechanical 80

90 / 1.0 (10)

678

694

2064

92 / 392

Stainless Steel

60

1.84

3.1

0

220-240v, 50Hz

Single

10

220-240v, 50Hz

Single

3

13

16

NOMINAL HOT WATER VOLUME (LITRES)

ErP RATING

HEAT LOSS (kWh/24hrs)

HEAT LOSS (W)

WATER Flow Rate (l/min) W50 - W85 - W112 - HW140

Primary Pump

Sanitary Hot Water Pump

Connection Size (mm) Heating / DHW (mm)

Primary Expansion Vessel (Litres)

Charge Pressure (MPa (Bar))

WATER SAFETY Water Circuit Control Thermistor (°C)

DEVICES Pressure Relief Valve (MPa (Bar))

Expansion Relief Valve (Cold)

DHW Cylinder Control Thermistor

High Limit Stat (°C)

Temp and Pressure Relief Valve (°C) / (MPa (Bar))

DIMENSIONS (mm) Width

Depth

Height

WEIGHT EMPTY / FULL (kg)

CYLINDER MATERIAL Cylinder Cylinder Material

Insulation Insulation Type

Insulation Thickness (mm)

Standing Heat Loss (kWh/24hrs)

GWP of Insulation

ODP of Insulation

ELECTRICAL DATA Control Board Electrical Supply

Phase

Fuse Rating - MCB Sizes (A)*1

Electrical Supply

Phase

Capacity (kW)

Max Running Current (A)

Fuse Rating - MCB Sizes (A)*1

MECHANICAL ZONES

OPTIONAL SIMPLIFIED WIRELESS ROOM THERMOSTAT AND WIRELESS RECEIVER

optionally powered byoutdoor unit

Immersion Heater

14.3 - 25.8 - 32.1 - 40.1

2 x Grundfos UPS2 15-60

Grundfos UPSO 15-60 CIL2

CFC / HCFC-free flame-retardant expanded Polyurethane

DHW and 1 Heating Zone*2

PAR-WT50-E Controller and PAR-WR51-E Receiver

Includes secondary coil for connection to solar thermal systems

Optional 2-zone energy efficient space heating control

Pre-plumbed and wired for faster installation

Hybrid function, for use with conventional boilers

Energy monitoring as standard

Key Features FTC5 Controller

Mitsubishi Electric’s fifth generation controller(FTC5) includes intelligent room temperaturecontrol as standard. This together withadvanced weather compensation ensures the system delivers efficient, comfortableheating regardless of the season. FTC5 now also includes energy monitoring showing consumed and produced energy.

Freedom Heat Pumps - www.freedomhp.co.uk

Page 21: Heating and Ventilation Product Catalogue Info/Mitsubishi/2019_Heating... · EHPX-VM2C FTC5 Packaged Hydrobox for Ecodan Monobloc Units PUHZ-SW Split Air Source Heat Pumps EHST20(D)(C)-MHCW

Page 21 Heating and Ventilation Product Catalogue 2019

Product Dimensions EHPT21-30X-UKHSCW

Front View Side View

*All dimensions in mm

EHPT21X-UKHSCW

EHPT25X-UKHSCW

EHPT30X-UKHSCW

Overall HeightModel

1497

1749

2064

Upper View

Freedom Heat Pumps - www.freedomhp.co.uk

Page 22: Heating and Ventilation Product Catalogue Info/Mitsubishi/2019_Heating... · EHPX-VM2C FTC5 Packaged Hydrobox for Ecodan Monobloc Units PUHZ-SW Split Air Source Heat Pumps EHST20(D)(C)-MHCW

Page 22 Heating and Ventilation Product Catalogue 2019

The packaged hydrobox offers a highly adaptable heating solution for retrofit or new build.

Designed specifically to integrate with the Ecodan monobloc air source heat pump range and a third party cylinder, the hydroboxprovides hydraulic components with an advanced simplified graphical user interface and controls. Fast commissioning via anSD card and energy monitoring functions are now included.EHPX-VM2C

FTC5 Packaged Hydrobox for Ecodan Monobloc Units

*1 MCB Sizes BS EN60898-2 & BS EN60947-2

HYdrOBOX EHPX-VM2C

0 ~ +35°C (RH<80%)

28

14.3 - 25.8 - 32.1 - 40.1

Grundfos UPM2 15 70 - 130

28

10

0.1 (1)

1 - 80

0.3 (3)

Supplied

80

90

121

530

360

800

37 / 42

220-240v, 50Hz

Single

10

220-240v, 50Hz

Single

2

9

16

OPERATING AMBIENT TEMPERATURE (°C DB)

SOUND PRESSURE LEVEL AT 1M (dBA)

WATER DATA

WATER SAFETY DEVICES

DIMENSIONS (mm)

WEIGHT EMPTY / FULL (kg)

ELECTRICAL DATA

Flow Rate (l/min) W50 - W85 - W112 - HW140

Pump

Connection Size (mm)

Primary Expansion Vessel (Litres)

Charge Pressure (MPa (Bar))

Control Thermistor (°C)

Pressure Relief Valve (Mpa (Bar))

Flow Sensor (minimum flow 5L/min)

Booster Heater Control Thermistor (°C)

Booster Heater Manual Reset Thermostat (°C)

Booster Heater Thermal Cut Off (°C)

Width

Depth

Height

Electrical Supply

Phase

Fuse Rating - MCB Sizes (A)*1

Electrical Supply

Phase

Capacity (kW)

Max Running Current (A)

Fuse Rating - MCB Sizes (A)*1

Control Board -optionally powered

by outdoor unit

Booster Heater -optionally powered

if required

OPTIONAL SIMPLIFIED WIRELESS ROOM THERMOSTAT AND WIRELESS RECEIVER PAR-WT50-E Controller and PAR-WR51-E Receiver

2-zone energy efficient space heating control

Sleek modern design

Pre-plumbed and wired for faster installation

Hybrid function, for use with conventional boilers

Energy monitoring as standard

Key Features FTC5 Controller

Mitsubishi Electric’s fifth generation controller(FTC5) includes intelligent room temperaturecontrol as standard. This together withadvanced weather compensation ensures the system delivers efficient, comfortableheating regardless of the season. FTC5 now also includes energy monitoring showing consumed and produced energy.

Freedom Heat Pumps - www.freedomhp.co.uk

Page 23: Heating and Ventilation Product Catalogue Info/Mitsubishi/2019_Heating... · EHPX-VM2C FTC5 Packaged Hydrobox for Ecodan Monobloc Units PUHZ-SW Split Air Source Heat Pumps EHST20(D)(C)-MHCW

Page 23 Heating and Ventilation Product Catalogue 2019

Product Dimensions EHPX-VM2C

28mm/Compression

28mm/Compression

28mm/Compression

28mm/Compression

G1/2” female (valve portwithin hydrobox casing)

A

B

C

D

E

F

Pipe description Connection Size/TypeLetter

Space heating/ Indirect DHWcylinder (primary) return connection

Space heating/ Indirect DHWcylinder (primary) flow connection

Flow connection from heat pump

Return connection from heat pump

Discharge pipe (by installer)from pressure relief valve

Electrical cable inlets

Front View Right View Rear View Lower View

Freedom Heat Pumps - www.freedomhp.co.uk

Page 24: Heating and Ventilation Product Catalogue Info/Mitsubishi/2019_Heating... · EHPX-VM2C FTC5 Packaged Hydrobox for Ecodan Monobloc Units PUHZ-SW Split Air Source Heat Pumps EHST20(D)(C)-MHCW

Page 24 Heating and Ventilation Product Catalogue 2019

Our range of Ecodan split air source heat pumps includes 5, 7.5 and 12kW sizes. With the ability to cascade up to six units of the same output Ecodan split systems offer a capacity range from 5 to 72kW.Designed to suit a wide number of applications, these models offer a viable solution for the varyingrequirements that domestic and small commercial applications demand.

Certificate Number: MCS HP0002

Product Type: Heat Pumps

Product Reference:

PUHZ-SW50VKA-BS, PUHZ-SW75VHA-BS

PUHZ-SW120VHA-BS

PUHZ-SWEcodan Split Air Source

Heat Pumps

PUHZ-SW75VHA-BSPUHZ-SW120VHA-BS

OUTdOOr UniT PUHZ-SW50VKA-BS PUHZ-SW75VHA-BS PUHZ-SW120VHA-BS

A++

125%

3.20

A++

163%

4.16

A

98%

5.25

1.84

2.85

-15 ~ +35°C

46

42

11.8

809+62*8

300

630

43

R410A

1.4 / 2.9

12.7 (1/2") / 6.35 (1/4")

Flared

40

2

30

220-240v, 50Hz

Single

3.8 [13]

16

A++

127%

3.26

A++

154%

3.92

A

93%

7.0

2.24

3.12

-20 ~ +35°C

51

48

22.9

950

330+30*5

943

75

R410A

3.2 / 6.7

15.88 (5/8") / 9.52 (3/8")

Flared

40

5

10

220-240v, 50Hz

Single

8.1 [19]

25

A++

125%

3.21

A++

162%

4.13

A

99%

11.2

3.71

3.02

-20 ~ +35°C

54

51

45.9

950

330+30*5

1350

118

R410A

4.6 / 9.6

15.88 (5/8") / 9.52 (3/8")

Flared

75

5

30

220-240v, 50Hz

Single

17.5 [29.5]

40

HEAT PUMP SPACE

HEATER - 55˚C

HEAT PUMP SPACE

HEATER - 35˚C

HEAT PUMP COMBINATION

HEATER - Large Profile*1

HEATING*2

(A-3/W35)

OPERATING AMBIENT TEMPERATURE (°C DB)*7

SOUND PRESSURE LEVEL AT 1M (dBA*3 *4

LOW NOISE MODE (dBA)*3

WATER DATA - Water connections made at indoor hydrobox

DIMENSIONS (mm)

WEIGHT (kg)

REFRIGERANT

ELECTRICAL DATA

ErP Ratingɳs

SCOP

ErP Ratingɳs

SCOP

ErP Ratingɳwh

Capacity (kW)

Power Input (kW)

COP

Flow Rate (l/min)

Width

Depth

Height

Type

Charge (kg) / CO2 Equivalent (t) - 10m pipe length

Pipe Size - Gas/Liquid (mm (in))

Connection Type

Max Pipe Length (m)

Min Pipe Length (m)

Max Height Difference (m)

Electrical Supply

Phase

Nominal Running Current [MAX] (A)

Fuse Rating - MCB Sizes (A)*6

*1 Combination with EHST20(D)(C)-MHCW Cylinders*2 Under normal heating conditions at outdoor temp: -3°CDB / -4°CWB, outlet water temp 35°C, inlet water temp 30°C*3 Under normal heating conditions at outdoor temp: 7°CDB / 6°CWB, outlet water temp 35°C, inlet water temp 30°C as tested to BS EN14511*4 Sound power level of the PUHZ-SW50VKA is 62dBA, PUHZ-SW75VHA2 is 65.6dBA, PUHZ-SW120VHA is 68.8dBA. as tested to BS EN12102*5 Grille*6 MCB Sizes BS EN60898-2 & BS EN60947-2*7 Heating maximum ambient temperature ~21°CDB, DHW Hot water maximum ambient temperature ~35°CDB*8 Electrical cover

ɳs is the seasonal space heating energy efficiency (SSHEE) ɳwh is the water heating energy efficiency

Split unit allowing water connections to be made internally

Single phase power supply with a low starting current

Low maintenance and quiet to run

Hybrid function for use with conventional boilers

Energy monitoring as standard

Key Features

Freedom Heat Pumps - www.freedomhp.co.uk

Page 25: Heating and Ventilation Product Catalogue Info/Mitsubishi/2019_Heating... · EHPX-VM2C FTC5 Packaged Hydrobox for Ecodan Monobloc Units PUHZ-SW Split Air Source Heat Pumps EHST20(D)(C)-MHCW

Page 25 Heating and Ventilation Product Catalogue 2019

Product Dimensions PUHZ-SW50VKA-BS Product Dimensions PUHZ-SW75VHA-BS Product Dimensions PUHZ-SW120VHA-BS

Upper View

Front View

Upper View

Front View

Upper View

Front View

Freedom Heat Pumps - www.freedomhp.co.uk

Page 26: Heating and Ventilation Product Catalogue Info/Mitsubishi/2019_Heating... · EHPX-VM2C FTC5 Packaged Hydrobox for Ecodan Monobloc Units PUHZ-SW Split Air Source Heat Pumps EHST20(D)(C)-MHCW

Page 26 Heating and Ventilation Product Catalogue 2019

The split cylinders offer a highly adaptable heating solution for retrofit or new build.

Designed specifically to operate with the Ecodan split air source heat pump range, the split cylinder provides improved performance and faster heat up times through the use of plate heat exchanger technology. Fast commissioning via an SD card and energy monitoringfunctions are now included.EHST20(d)(C)

-MHCW

FTC5 Cylinders for

Ecodan Split Units

*1 MCB Sizes BS EN60898-2 & BS EN60947-2 *2 Optional 2 zone accessory pack available

CYLindEr EHST20d-MHCW EHST20C-MHCW

Flow Rate (l/min) Primary PumpSanitary Hot Water PumpConnection Size (mm) Heating / DHWPrimary Expansion Vessel (Litres)Charge Pressure (MPa (Bar))Control Thermistor (°C)Pressure Relief Valve (MPa (Bar))Flow Sensor (minimum flow 5L/min)Control Thermistor (°C)Temp and Pressure Relief Valve (°C)/ (MPa (Bar))WidthDepthHeight

TypeConnection Size - Gas Liquid (mm)(in)Connection TypeElectrical SupplyPhaseFuse Rating - MCB Sizes (A)*1

Electrical SupplyPhaseCapacity (kW)Max Running Current (A)Fuse Rating - MCB Sizes (A)*1

Water Circuit

DHW Cylinder

11.8 (SW50)Grundfos UPM2 15 70 - 130

Grundfos UPSO 15-60 130 CIL228 / 22

120.1 (1)1 - 800.3 (3)

Supplied40-70

90 / 0.7 (7)5956801600

103 / 312R410A

12.7 (1/2") / 6.35 (1/4")Flared

220-240v, 50HzSingle

10220-240v, 50Hz

Single31316

22.9 (SW75) / 45.9 (SW120)Grundfos UPM2 15 70 - 130

Grundfos UPSO 15-60 130 CIL228 / 22

120.1 (1)1 - 800.3 (3)

Supplied40-70

90 / 0.7 (7)5956801600

110 / 320R410A

15.88 (5/8") / 9.52 (3/8")Flared

220-240v, 50HzSingle

10220-240v, 50Hz

Single31316

200PUHZ-SW50VKA-BS

A++

A++

A0 ~ +35°C (RH<80%)

28

200PUHZ-SW75VHA-BS / PUHZ-SW120VHA-BS

A++ / A++

A++ / A++

A / A0 ~ +35°C (RH<80%)

28

Control Board -optionally powered

by outdoor unit

Immersion Heater

OPTIONAL SIMPLIFIED WIRELESS ROOM THERMOSTAT AND WIRELESS RECEIVER PAR-WT50-E Controller and PAR-WR51-E Receiver

MECHANICAL ZONES DHW and 1 Heating Zone*2DHW and 1 Heating Zone*2

NOMINAL HOT WATER VOLUME (LITRES)

APPLICABLE OUTDOOR UNIT

OPERATING AMBIENT TEMPERATURE (°C DB)

SOUND PRESSURE LEVEL AT 1M (dBA)

WATER DATA

WATER SAFETY DEVICES

DIMENSIONS (mm)

WEIGHT EMPTY / FULL (kg)

REFRIGERANT

ELECTRICAL DATA

HEAT PUMP SPACE HEATER - 55˚CHEAT PUMP SPACE HEATER - 35˚CHEAT PUMP COMBINATION HEATER - Large Profile

ErP RatingErP RatingErP Rating

No hydrobox required

Optional 2-zone energy efficient space heating control

Pre-plumbed and wired for faster installation

Hybrid function for use with conventional boilers

Energy monitoring as standard

Key Features FTC5 Controller

Mitsubishi Electric’s fifth generation controller(FTC5) includes intelligent room temperaturecontrol as standard. This together withadvanced weather compensation ensures the system delivers efficient, comfortableheating regardless of the season. FTC5 now also includes energy monitoring showing consumed and produced energy.

Freedom Heat Pumps - www.freedomhp.co.uk

Page 27: Heating and Ventilation Product Catalogue Info/Mitsubishi/2019_Heating... · EHPX-VM2C FTC5 Packaged Hydrobox for Ecodan Monobloc Units PUHZ-SW Split Air Source Heat Pumps EHST20(D)(C)-MHCW

Page 27 Heating and Ventilation Product Catalogue 2019

Product Dimensions EHST20(D)(C)-MHCW

Front View Right ViewLeft View

DHW outlet connection

Cold water inlet connection

Space heating return connection

Space heating flow connection

Refrigerant (GAS)

Refrigerant (LIQUID)

Electrical cable inlets

A

B

C

D

E

F

G

Pipe description Connection Size/TypeLetter

Upper View

22mm/Compression

22mm/Compression

28mm/Compression

28mm/Compression

12.7mm/Flare (EHST20D-MHCW)

15.88mm/Flare (EHST20C-MHCW)

6.35mm/Flare (EHST20D-MHCW)

9.52mm/Flare (EHST20C-MHCW)

Freedom Heat Pumps - www.freedomhp.co.uk

Page 28: Heating and Ventilation Product Catalogue Info/Mitsubishi/2019_Heating... · EHPX-VM2C FTC5 Packaged Hydrobox for Ecodan Monobloc Units PUHZ-SW Split Air Source Heat Pumps EHST20(D)(C)-MHCW

Page 28 Heating and Ventilation Product Catalogue 2019

The split hydrobox offers a highly adaptable heating solution for retrofit or new build.

Designed specifically to integrate with the Ecodan split air source heat pump range and a third party cylinder, the split hydrobox provideshydraulic components with an advanced simplified graphical user interface and controls. Fast commissioning via an SD card and energymonitoring functions are now included.EHS(d)(C)-MEC

FTC5 Hydroboxes for

Ecodan Split Units

*1 MCB Sizes BS EN60898-2 & BS EN60947-2

HYdrOBOX EHSd-MEC EHSC-MEC

A++

A++

0 ~ +35°C (RH<80%)PUHZ-SW50VKA-BS

28

11.8 (SW50)

Grundfos UPM2 15 70 - 130

28

0.1 (1)

1 - 80

0.3 (3)

Supplied

HEAT PUMP SPACE HEATER - 55˚CHEAT PUMP SPACE HEATER - 35˚COPERATING AMBIENT TEMPERATURE (°C DB)APPLICABLE OUTDOOR UNITSSOUND PRESSURE LEVEL AT 1M (dBA)

WATER DATA

WATER SAFETY DEVICES

DIMENSIONS (mm)

WEIGHT EMPTY / FULL (kg)

REFRIGERANT

ELECTRICAL DATA

Flow Rate (l/min)

Pump

Connection Size (mm)

Charge Pressure (MPa (Bar))

Control Thermistor (°C)

Pressure Relief Valve (MPa (Bar))

Flow Switch

Control Board -optionally powered

by outdoor unit

22.9 (SW75) / 45.9 (SW120)

Grundfos UPM2 15 70 - 130

28

0.1 (1)

1 - 80

0.3 (3)

Supplied

A++ / A++

A++ / A++

0 ~ +35°C (RH<80%)PUHZ-SW75VHA-BS / PUHZ-SW120VHA-BS

28

OPTIONAL SIMPLIFIED WIRELESS ROOM THERMOSTAT AND WIRELESS RECEIVER PAR-WT50-E Controller and PAR-WR51-E Receiver

WidthDepthHeight

Type

Connection Size - Gas/Liquid (mm (in)

Connection Type

Electrical Supply

Phase

Fuse Rating - MCB Sizes (A)*1

530360800

38 / 44

R410A

12.7 (1/2") / 6.35 (1/4")

Flared

220-240v, 50Hz

Single

10

530360800

42 / 49

R410A

15.88 (5/8") / 9.52 (3/8")

Flared

220-240v, 50Hz

Single

10

ErP Rating

ErP Rating

2-zone energy efficient space heating control

Sleek modern design

Pre-plumbed and wired for faster installation

Hybrid function, for use with conventional boilers

Energy monitoring as standard

Key Features FTC5 Controller

Mitsubishi Electric’s fifth generation controller(FTC5) includes intelligent room temperaturecontrol as standard. This together withadvanced weather compensation ensures the system delivers efficient, comfortableheating regardless of the season. FTC5 now also includes energy monitoring showing consumed and produced energy.

Freedom Heat Pumps - www.freedomhp.co.uk

Page 29: Heating and Ventilation Product Catalogue Info/Mitsubishi/2019_Heating... · EHPX-VM2C FTC5 Packaged Hydrobox for Ecodan Monobloc Units PUHZ-SW Split Air Source Heat Pumps EHST20(D)(C)-MHCW

Page 29 Heating and Ventilation Product Catalogue 2019

Product Dimensions EHS(D)(C)-MEC

Front View Right View Rear View Lower View

28mm/Compression

28mm/Compression

6.35mm/Flare (EHSD-MEC)

9.52mm/Flare (EHSC-MEC)

12.7mm/Flare (EHSD-MEC)

15.88mm/Flare (EHSC-MEC)

G1/2” female (valve portwithin hydrobox casing)

-

A

B

C

D

E

F

Pipe description Connection Size/TypeLetter

Space heating/ Indirect DHWcylinder (primary) return connection

Space heating/ Indirect DHWcylinder (primary) flow connection

Refrigerant (Liquid)

Refrigerant (Gas)

Discharge pipe (by installer) from pressure relief valve

Electrical cable inlets

Freedom Heat Pumps - www.freedomhp.co.uk

Page 30: Heating and Ventilation Product Catalogue Info/Mitsubishi/2019_Heating... · EHPX-VM2C FTC5 Packaged Hydrobox for Ecodan Monobloc Units PUHZ-SW Split Air Source Heat Pumps EHST20(D)(C)-MHCW

Page 30 Heating and Ventilation Product Catalogue 2019

FTC2B FlowTemperatureController

For use with Ecodan

Monobloc Units and

Third Party BEMS

336

69

278

2.4

0~+35ºC (RH<80%)

Powered from outdoor unit (240v)

Single

DIMENSIONS (mm)

WEIGHT (kg)

OPERATING AMBIENT TEMPERATURE (°C DB)

ELECTRICAL DATA

Width

Depth

Height

Electrical Supply

Phase

FTC2B PAC-iF032B-E

The FTC2B has been developed to allow the Ecodan PUHZ range to interface with third party or BEMS(Building Energy Management System) controls. A combination of volt free and voltage inputs allow the EcodanPUHZ monobloc range to be used in applications where only simple on/off and temperature control is required.

Functions that can be controlled by third party controls:On/Off heating mode On/Off holiday mode

On/Off heating ECO mode On/Off legionella mode

On/Off hot water mode Change water flow temperature

Functions that can be monitored by third party controls:Unit running

Error

Defrost

The ability to interface with third party controls opens up a huge number of application opportunities. Many processes simply require a heatsource that provides hot water, without polished end user controls. The FTC2B controller allows the Ecodan PUHZ to be used in theseapplications. FTC2B inputs and outputs can be used in conjunction with local BEMS.

Product Dimensions PAC-IF032B-E

Front View Side View

Freedom Heat Pumps - www.freedomhp.co.uk

Page 31: Heating and Ventilation Product Catalogue Info/Mitsubishi/2019_Heating... · EHPX-VM2C FTC5 Packaged Hydrobox for Ecodan Monobloc Units PUHZ-SW Split Air Source Heat Pumps EHST20(D)(C)-MHCW

Page 31 Heating and Ventilation Product Catalogue 2019

The i-Life2 Slim Fan Assisted Radiator designed to work seamlessly with existing heating or renewable technologiesi-LiFE2 Slim

Fan Assisted radiator

1. Room temperature 27°C d.b./19°C w.b.; Chilled water (in/out) 7/12°C

2. Room temperature 20°C d.b.; Hot water (in/out) 50/* °C (with identical flow note 1)

3. Sound pressure in semi-anechoic room at 1 (m.) from fan front and 1 (m.) from the ground

4. Sound power on the basis of measurements made in compliance with Eurovent 8/2

5. Unit in standard configuration/execution, without optional accessories

i-Life2 Slim units are managed by a variable speed fan motor

that continuously modulates the fan speed

MOdEL i-LiFE2 SLiM 80 i-LiFE2 SLiM 170

230/1/5018

1250.760.660.04

60.880.04

84150

930.690.540.03

50.780.04

63544

510.40.3

0.022

0.50.02

32433

737 - 131 - 57917

Power supply V/ph/HzMax power input W2 PIPES SYSTEM CONFIGURATIONMAX SPEEDAir flow m³/hTotal capacity in cooling mode (1) kWSensible capacity in cooling mode (1) kWMax water flow (1) m³/hMax pressure drop (1) kPaTotal capacity in heating mode (2) kWWater flow in heating (2) m³/hPressure drop in heating (2) kPaSound Pressure (3) dB(A)Sound Power (4) dB(A)MED SPEEDAir flow m³/hTotal capacity in cooling mode (1) kWSensible capacity in cooling mode (1) kWMax water flow (1) m³/hMax pressure drop (1) kPaTotal capacity in heating mode (2) kWWater flow in heating (2) m³/hPressure drop in heating (2) kPaSound Pressure (3) dB(A)Sound Power (4) dB(A)MIN SPEEDAir flow m³/hTotal capacity in cooling mode (1) kWSensible capacity in cooling mode (1) kWMax water flow (1) m³/hMax pressure drop (1) kPaTotal capacity in heating mode (2) kWWater flow in heating (2) m³/hPressure drop in heating (2) kPaSound Pressure (3) dB(A)Sound Power (4) dB(A)SIZE AND WEIGHTWidth - Depth - Height (5) mmOperating weight (5) kg

230/1/5027

2771.751.530.08

52.110.10

84251

2211.391.170.07

31.650.08

53645

1220.810.670.04

11.060.05

22635

937 - 131 - 57920

Stylish - At only 13cm deep, the sleek and elegant satin-white, wall mounted cabinet is designed to blend seamlessly into any setting

Flexible - Packed with advanced controls and functions, the i-Life2 Slim will work with traditional heating or renewable systems such as heat pumps

Easy to Use - Airflow is managed by deflectors at the top of the unit, which open and close automatically ensuring fast even heat distribution

Key Features

i-LIFE2 SLIM 80

737mm

579mm

131mm

i-LIFE2 SLIM 170

937mm

579mm

131mm

Product Dimensions Product Dimensions

Freedom Heat Pumps - www.freedomhp.co.uk

Page 32: Heating and Ventilation Product Catalogue Info/Mitsubishi/2019_Heating... · EHPX-VM2C FTC5 Packaged Hydrobox for Ecodan Monobloc Units PUHZ-SW Split Air Source Heat Pumps EHST20(D)(C)-MHCW

Page 32 Heating and Ventilation Product Catalogue 2019

MELCloud is a Cloud based solution for controlling your Mitsubishi Electric Ecodan heating system either locally or remotely by PC, Mac, Tablet or Smartphone via the Internet.

The set up and remote operation of your Ecodan heating system via MELCloud is simple and straight forward. All you need isa wireless connection in your home or building where the Ecodan is located and an Internet connection on your mobile or fixeddevice. To set up the system, the router and the Ecodan Wi-Fi interface need pairing and this is done simply and quickly viathe WPS button found on all mainstream routers.

View electrical energy consumed and heat energy produced

View and control your heating and hot water from anywhere in the world

Set up of 7 day weekly schedule / holiday mode

Temperature history reports

Live weather feed at location of Ecodan

Share / restrict access and control of the Ecodan system

Works on any PC / Mac / Tablet / Smartphone

Key Features

MELCloud Wi-Fi Control

Available for any FTC5 based system, new or retrofit using a MAC567IF interface

Freedom Heat Pumps - www.freedomhp.co.uk

Page 33: Heating and Ventilation Product Catalogue Info/Mitsubishi/2019_Heating... · EHPX-VM2C FTC5 Packaged Hydrobox for Ecodan Monobloc Units PUHZ-SW Split Air Source Heat Pumps EHST20(D)(C)-MHCW

Page 33 Heating and Ventilation Product Catalogue 2019

Available for PC, Mac, Tablet or Smartphone

For a demonstration ofMitsubishi Electric’s MELCloud visit our website:melcloud.com and click ‘Login’

All Ecodan FTC5 systems have energy monitoring functionality as standard and the ability to connect to MELCloud. A MAC-567IF Wi-Fi Interface is required to use MELCloud.

Supported Ecodan Models

Wi-Fi Interface MAC-567IF

DESCRIPTION

CONNECT TO

MAX NUMBER OF UNITS

COMPATIBILITY

POWER SUPPLY

DIMENSIONS (WxDxH) mm

CONTROL On/Off

Mode

Heating Setpoint

Hot Water Boost

2-Zone Control

Holiday Mode

Timer

Frost Protection

MONITOR On/Off

Mode

Heating Setpoint

Tank Temperature

Tank Target Temperature

Outside Temperature

Fault Codes

Consumed Electrical Energy

Produced Heat Energy

Wi-Fi Interface

Indoor Unit

1

Ecodan FTC5

From indoor unit

79 x 18.5 x 44

Please note:This is not definitive list of all compatible devices, other similar devices which use supported Operating Systems or Internet Browsers should also work either via dedicated Apps or via Web Browser / Web Client options. Please note that user experience may vary slightly depending on hardware and software combination.

Supported Hardware / Software

Tablets (Apps or Web Client)

Apple iPad / iPad mini

Samsung Galaxy Tab / Note

Google Nexus

Dell Latitude 10

Microsoft Surface

BlackBerry PlayBook

Smartphones (Apps or Web Client)

Apple iPhone

Samsung Galaxy S

Google Nexus

Nokia Lumia

BlackBerry Z10

Operating Systems

Android

Apple iOS / OS

Microsoft Windows

BlackBerry

Internet Browsers (Web Client only)

Microsoft Internet Explorer

Google Chrome

Apple Safari

Mozilla Firefox

Opera

Supported Hardware / Software

Freedom Heat Pumps - www.freedomhp.co.uk

Page 34: Heating and Ventilation Product Catalogue Info/Mitsubishi/2019_Heating... · EHPX-VM2C FTC5 Packaged Hydrobox for Ecodan Monobloc Units PUHZ-SW Split Air Source Heat Pumps EHST20(D)(C)-MHCW

Page 34 Heating and Ventilation Product Catalogue 2019

Energy MonitoringPacks

All Ecodan Flow Temperature Control 5 (FTC5) systems come with free energy monitoring as standard.System users are able to measure both consumed electrical energy and produced heat energy to the nearest kWh. Further energy monitoring packs are also available, ranging from electric meter packs, through to a Renewable Heat Incentive (RHI) compliant Metering and Monitoring Service Pack (MMSP) which allows additional RHI payments to be claimed.

In addition to the basic system functionality features, i.e. hot water and heating status, with FTC5 the systems energy performance can alsonow be viewed. Historic energy consumption, heat production and run cost reports are available via the main controller, SD card or MELCloud.

Records and measures to 1 pulse per watt hour (Wh) ensuringaccurate energy consumption figures. This pack is ideal for userswanting exact energy consumption, e.g. Housing Associations.

2 x Measuring InstrumentDirective (MID) approved electric meters

EMP2Energy Monitoring

Pack Two

Calculated estimate of nearest kilowatt hour (kWh). This pack is ideal for end user guidance.

Optional Wi-Fi interface for use with MELCloud (MAC-567IF)

Advanced on-board energy

monitoring as standard

EMP1Energy Monitoring

Pack One

Resolution / ApplicationContentsPack Code

Energy MonitoringPacks

Records and measures to 1 pulse per watt hour (Wh) for bothelectricity consumed and heat produced. This pack is RHI MMSPcompliant, which allows additional RHI payments to be claimed.

2 x MID approved electric meters.1 x MID approved heat meter.MAC-567IF Wi-Fi interface and 1 years rolling data storage

EMP3-MEnergy Monitoring

Pack Three -

Monobloc

Records and measures to 1 pulse per watt hour (Wh) for bothelectricity consumed and heat produced. This pack is RHI MMSPcompliant, which allows additional RHI payments to be claimed.

2 x MID approved electric meters.1 x MID approved heat meter.MAC-567IF Wi-Fi interface and 1 years rolling data storage

EMP3-SEnergy Monitoring

Pack Three - Split

Records and measures to 1 pulse per kilowatt hour (kWh). This packis for hybrid systems requiring metering to comply with the RHI.

1 x MID approved heat meterEMPH-MEnergy Monitoring

Pack -

Hybrid-Monobloc

Records and measures to 1 pulse per kilowatt hour (kWh). This packis for hybrid systems requiring metering to comply with the RHI.

1 x MID approved heat meterEMPH-S

Records and measures to 1 pulse per watt hour (Wh) for bothelectricity consumed and heat produced. This pack is RHI MMSPcompliant, which allows additional RHI payments to be claimed.

2 x MID approved electric meters (1 x single phase, 1 x 3 phase). 1 x MID approved heat meter. MAC-567IF Wi-Fi interface and 1 years rolling data storage

EMP3-M-

3ph

Energy Monitoring

Pack Three -

Monobloc 3 phase

Energy Monitoring

Pack - Hybrid-Split

Optional Wi-Fi interface for use with MELCloud (MAC-567IF)

Optional Wi-Fi interface for use with MELCloud (MAC-567IF)

Optional Wi-Fi interface for use with MELCloud (MAC-567IF)

Freedom Heat Pumps - www.freedomhp.co.uk

Page 35: Heating and Ventilation Product Catalogue Info/Mitsubishi/2019_Heating... · EHPX-VM2C FTC5 Packaged Hydrobox for Ecodan Monobloc Units PUHZ-SW Split Air Source Heat Pumps EHST20(D)(C)-MHCW

Page 35 Heating and Ventilation Product Catalogue 2019

DESCRIPTION MODEL  REF.

Accessories /Optional Extras

PUHZ / QUHZ Accessories

Standalone Cascade Slave Controller

Wireless Controller Transmitter

Wireless Controller Reciever

Return Thermistor

Flow and Return Temperature Sensors 5m

High Temperature Sensor 5m

Cylinder DHW Temp Sensor 5m

Cylinder DHW Temp Sensor 30m

Packaged Cylinder Controller Blanking Plate

Small Drain Socket Kit (VHA)

Internal Air Temperature Sensor; including Cover

Low Noise Mode 3-Wire Adaptor (VHA)

Magnetic Particle Filter ≤8.5kW (22mm)

Magnetic Particle Filter >8.5kW (28mm)

Ecodan Anti-Vibration Fix-It-Foot 600mm - Pair

Ecodan Reinforced 27.5kg Lightweight Slab including Anti-Vibration Fix-It-Foot 600mm

Insulated Flexible Connection Pipes (QUHZ) - Pair

Insulated Flexible Connection Pipes (22mm x 500mm) - Pair

Insulated Flexible Connection Pipes (28mm x 500mm) - Pair

Insulated Flexible Connection Pipes (28mm x 300mm) Elbow - Pair

Insulated Through Wall Sleeve Kit (85mm)

External Pipework Trunking Length 2x 1m 140mm Black

External Pipework Trunking Length 1x 2m 140mm Black

External Pipework Trunking Length Connector 140mm Black

External Pipework Trunking Wall Cover 140mm Black

External Pipework Trunking 90˚ Elbow 140mm Black

External Pipework Trunking External Corner 140mm Black

External Pipework Trunking Internal Corner 140mm Black

Isolator Switch - 4 Pole - 20A Rotary Enclosed IP65

Isolator Switch - 4 Pole - 32A Rotary Enclosed IP65

Nitrogen Filled Expansion Vessel Kit including Filling Loop, Safety Valve, Presure Gauge and Bracket - 8ltr

Nitrogen Filled Expansion Vessel Kit including Filling Loop, Safety Valve, Presure Gauge and Bracket - 12ltr

Nitrogen Filled Expansion Vessel Kit including Filling Loop, Safety Valve, Presure Gauge and Bracket - 18ltr

Antifreeze containing Biocide - 10ltr

Antifreeze containing Biocide - 25ltr

MELCloud Wi-Fi Interface

2 Zone Pack 1 - suitable for 2 zone applications where the temperature of both zones are the same. Contains 1x pump and isolation valves

2 Zone Pack 2 - suitable for 2 zone applications where the temperature of both zones are different. Contains 1x pump,isolation valves, mixing valve / actuator plus standard flow and return sensors for the extra zone

PAC-SIF051B-ER2

PAR-WT50R-E

PAR-WR51R-E

PAC-TH010-E

PAC-TH011-E

PAC-TH011HT-E

PAC-TH011TK-E

PAC-TH011TKL-E

PAC-RC01-ER2

PAC-SH71DS-E

PAC-SE41TS-E

PAC-SA89TA-EP

ACC-MFI-022

ACC-MFI-028

ACC-AVM-001

ACC-AVS-001

ACC-FCP-QUHZ

ACC-FCP-S22

ACC-FCP-S28

ACC-FCP-E28

ACC-FCP-TW1

ACC-TRU-LE1

ACC-TRU-LE2

ACC-TRU-JO1

ACC-TRU-CO1

ACC-TRU-EL1

ACC-TRU-EC1

ACC-TRU-IC1

ACC-ISO-020

ACC-ISO-032

ACC-EXV-K08

ACC-EXV-K12

ACC-EXV-K18

ACC-AFZ-010

ACC-AFZ-025

MAC-567IF

ACC-2ZP-K01

ACC-2ZP-K02

Freedom Heat Pumps - www.freedomhp.co.uk

Page 36: Heating and Ventilation Product Catalogue Info/Mitsubishi/2019_Heating... · EHPX-VM2C FTC5 Packaged Hydrobox for Ecodan Monobloc Units PUHZ-SW Split Air Source Heat Pumps EHST20(D)(C)-MHCW

Page 36 Heating and Ventilation Product Catalogue 2019

Specifically designed for large applications, the Ecodan CAHV air source heat pump monobloc system canoperate singularly, or form part of a multiple unit system. The CAHV also comes equipped with a wide rangeof controller features as standard.

A multiple unit system has the ability to cascade available units on and off to meet the load from a building. As an example of this modulation,a 16 unit system allows 0.5kW increments of capacity, from 18kW all the way up to 688kW. This level of modulation is unprecedentedwithin the heating industry and with cascade and rotation built in as standard, the Ecodan CAHV system is perfectly suited to a widerange of commercial applications.

Certificate Number: MCS HP0002

Product Type: Heat Pumps

Product Reference: CAHV-P500YA-HPB

Multiple unit cascade control of up to 688kW capacity, only water and electrical connections needed

Ability to rotate units based on accumulated run hours

Provides from 25ºC up to 70°C water flow temperatures without boost heaters

Low maintenance

Key Features

CAHVMonobloc Air Source

Heat Pump

OUTdOOr UniT CAHV-P500YB-HPB

*1 Under normal heating conditions at outdoor temp: -3°CDB / -4°CWB, outlet water temp 35°C, inlet water temp 30°C *2 Under normal heating conditions at outdoor temp: 7°CDB / 6°CWB, outlet water temp 35°C, inlet water temp 30°C as tested to BS EN14511*3 Sound power level of the CAHV-P500YA-HPB is 70.7dBA. Tested to BS EN12102 *4 MCB Sizes BS EN60898-2 & BS EN60947-2

ɳs is the seasonal space heating energy efficiency (SSHEE) ɳwh is the water heating energy efficiency

HEAT PUMP SPACE

HEATER - 55˚C

HEAT PUMP SPACE

HEATER - 35˚C

HEATING*1 Capacity (kW)

(A-3/W35) Power Input (kW)

COP

OPERATING AMBIENT TEMPERATURE (°C DB)

SOUND PRESSURE LEVEL AT 1M (dBA)*2*3

LOW NOISE MODE (dBA)*2

FLOW RATE (l/min)

WATER PRESSURE DROP (kPa)

DIMENSIONS (mm) Width

Depth

Height

WEIGHT (kg)

ELECTRICAL SUPPLY

PHASE

NOMINAL RUNNING CURRENT [MAX] (A)

FUSE RATING - MCB SIZES (A)*4

REFRIGERANT CHARGE (kg) R407C (GWP 1774)

/ CO2 EQUIVALENT (t)

A++

125%

3.19

A+

139%

3.54

42.6

15.2

2.80

-20~+40ºC

59

Variable

126

18

1978

759

1710 (1650 without legs)

526

380-415v, 50Hz

3

17.6 [52.9]

63

11 / 19.5

ErP Rating

ɳs

SCOP

ErP Rating

ɳs

SCOP

Freedom Heat Pumps - www.freedomhp.co.uk

Page 37: Heating and Ventilation Product Catalogue Info/Mitsubishi/2019_Heating... · EHPX-VM2C FTC5 Packaged Hydrobox for Ecodan Monobloc Units PUHZ-SW Split Air Source Heat Pumps EHST20(D)(C)-MHCW

Page 37 Heating and Ventilation Product Catalogue 2019

Product Dimensions CAHV-P500YB-HPB

Upper View

Front View Side View

Freedom Heat Pumps - www.freedomhp.co.uk

Page 38: Heating and Ventilation Product Catalogue Info/Mitsubishi/2019_Heating... · EHPX-VM2C FTC5 Packaged Hydrobox for Ecodan Monobloc Units PUHZ-SW Split Air Source Heat Pumps EHST20(D)(C)-MHCW

Page 38 Heating and Ventilation Product Catalogue 2019

*1 Under normal heating conditions at brine inlet: 0°C, outlet water temp 35°C as tested to BS EN14511 (60kW)*2 Under normal heating conditions at brine inlet: 0°C, outlet water temp 35°C as tested to BS EN14511 (45kW)*3 Under normal heating conditions at water inlet: 10°C, outlet water temp 35°C as tested to BS EN14511 (60kW)*4 Under normal heating conditions at water inlet: 10°C, outlet water temp 35°C as tested to BS EN14511 (45kW)*5 Sound power level as tested to BS EN12102 *6 Heat source inlet temperature above 27ºC and up to 45°C option must reverse the inlet and outlet heat source connections and refer to manual for dip switch changes*7 The system should be adequately protected from freezing *8 MCB Sizes BS EN60898-2 & BS EN60947-2

* LTHW - Low Temperature Hot Water

* Please use adequate frost protection to ensure pipework and the unit do not freeze

if the system is powered down

* Please do not use ground water or well water directly within the unit

* The water circuit must be a closed circuit

The inverter driven Ecodan CRHV monobloc ground / water source heat pump can operate singularly,or be banked together to create a system that can modulate and cascade available units on and off to meet the load from a building.

This level of modulation is unprecedented within the heating industry and with cascade and rotation built in as standard,the Ecodan CRHV system is perfectly suited to a wide range of commercial applications.

Bore holes, slinkies, aquifers, lakes, rivers, waste heat - can all be used as a heat source

Multiple unit cascade control of up to 16 units / 960kW

Ability to rotate units based on accumulated run hours

Provides up to 65°C water flow temperatures without booster heaters

Low maintenance, just electrical and water connections

Heat recovery applications can be achieved by moving heat between applications

Passive cooling possible by exchanging ground / water source with a chilled water system

Key Features

CrHVMonobloc Ground / Water

Source Heat Pump

PLEASE  NOTE: Full design criteria is needed to ascertain the capacity which couldchange based on heat source temperature and building flow temperature.

ɳs is the seasonal space heating energy efficiency (SSHEE)ɳwh is the water heating energy efficiency

CrHV UniT CRHV-P600YA-HPB

ErP Ratingɳs

SCOPErP Ratingɳs

SCOP

HEAT PUMP SPACE HEATER - 55˚C

HEAT PUMP SPACE HEATER - 35˚C

HEATING*1 Capacity (kW) 60(B0/W35) Power Input inc. pump (kW) 14.20 COP 4.23SEASONAL EFFICIENCY EN14825 (SPF) B0/W35 (60kW) 4.33HEATING*2 Capacity (kW) 45(B0/W35) Power Input inc. pump (kW) 10.20 COP 4.41SEASONAL EFFICIENCY EN14825 (SPF) B0/W35 (45kW) 4.03HEATING*3 Capacity (kW) 60(W10/W35) Power Input inc. pump (kW) 11.90 COP 5.08SEASONAL EFFICIENCY EN14825 (SPF) W10/W35 (60kW) 5.09HEATING*4 Capacity (kW) 45(W10/W35) Power Input inc. pump (kW) 8.89 COP 5.11SEASONAL EFFICIENCY EN14825 (SPF) W10/W35 (45kW) 4.55

SOUND DATA Pressure Level LpA at 1m (dBA) 50 Power Level LwA (dBA)*5 66

WATER DATA Heat Source (Brine) (l/s (m3/hr)) 1.5 to 4.1 (5.4 to 15) Building Side (LTHW) (l/s (m3/hr)) 1.5 to 4.4 (5.4 to 16) Heat Source Outlet (Brine) (mm (")) 50.8 (R2) screw Heat Source Inlet (Brine) (mm (")) 50.8 (R2) screw Building Side Outlet (LTHW) (mm (")) 50.8 (R2) screw Building Side Inlet (LTHW) (mm (")) 50.8 (R2) screw Heat Source Inlet (Brine) (°C) -5 to +27 Heat Source Inlet Option (Brine) (°C)*6 -5 to +45 Building Side Outlet (LTHW) (°C) +30 to +65 Min 30% Ethylene Glycol or equivalent Heat Source (Brine) (kPa) 12 Building Side (LTHW) (kPa) 7 Heat Source (Brine) (MPa(Bar)) 1 (10) Building Side (LTHW) (MPa(Bar)) 1 (10)DIMENSIONS Width (mm) 934 Depth (mm) 780 Height (mm) 1561WEIGHT (kg) 395

REFRIGERANT Type R410A Charge (kg) / CO2 Equivalent (t) 9 / 18.7 Max pressure (MPa (Bar)) 4.15 (41.5) Compressor Type Inverter Driven Circuit type Hermetically Sealed System

ELECTRICAL DATA Electrical Supply 415v, 50Hz Phase 3 Phase Maximum Running Current (A) 44 Fuse Rating - MCB Size (A)*8 50

Flow Rate Range

Mechanical Connections

Operating Temperature Range

Heat Source Fluid Type*7

Pressure Drop(at 1.5l/s inc 30% glycol in heat source fluid)

Maximum Working Pressure

A++

127%3.37A++

153%4.03

Freedom Heat Pumps - www.freedomhp.co.uk

Page 39: Heating and Ventilation Product Catalogue Info/Mitsubishi/2019_Heating... · EHPX-VM2C FTC5 Packaged Hydrobox for Ecodan Monobloc Units PUHZ-SW Split Air Source Heat Pumps EHST20(D)(C)-MHCW

Page 39 Heating and Ventilation Product Catalogue 2019

Product Dimensions CRHV-P600YA-HPB

Front View Side View

773

85

60(60)

23.5(23.5)

660

(780)

1561

HOT WATER OUTLETR2B

HOT WATER INLETR2B

HEAT SOURCE WATER INLETR2B

HEAT SOURCE WATER OUTLETR2B

Freedom Heat Pumps - www.freedomhp.co.uk

Page 40: Heating and Ventilation Product Catalogue Info/Mitsubishi/2019_Heating... · EHPX-VM2C FTC5 Packaged Hydrobox for Ecodan Monobloc Units PUHZ-SW Split Air Source Heat Pumps EHST20(D)(C)-MHCW

Page 40 Heating and Ventilation Product Catalogue 2019

DESCRIPTION MOdEL  rEF.

Accessories /Optional Extras

CAHV Accessories

Main Pipework Thermistor

Differential Pressure Switch for Water Systems

Wired Remote Controller

Centralised Controller

AE-200E Wall Mounted Box - for wall mounting

CrHV Accessories

Main Pipework Thermistor

Wired Remote Controller

External Temperature Sensor and Solar Guard

Differential Pressure Switch for Water Systems

TW-TH16

KS10-dPS 0.015-0.25

PAr-W21MAA-J

AE-200E

PAC-YG82TB

TW-TH16

PAr-W21MAA-J

TMP-O

KS10-dPS 0.015-0.25

Freedom Heat Pumps - www.freedomhp.co.uk

Page 41: Heating and Ventilation Product Catalogue Info/Mitsubishi/2019_Heating... · EHPX-VM2C FTC5 Packaged Hydrobox for Ecodan Monobloc Units PUHZ-SW Split Air Source Heat Pumps EHST20(D)(C)-MHCW

Ventilation

Freedom Heat Pumps - www.freedomhp.co.uk

Page 42: Heating and Ventilation Product Catalogue Info/Mitsubishi/2019_Heating... · EHPX-VM2C FTC5 Packaged Hydrobox for Ecodan Monobloc Units PUHZ-SW Split Air Source Heat Pumps EHST20(D)(C)-MHCW

Page 42 Heating and Ventilation Product Catalogue 2019

VL-50S2/ES2/Sr2

Wall Mounted Lossnay

Part of Mitsubishi Electric’s energy efficient Lossnay range, VL-50 total heat exchangers supply fresh

air inside a single room using simultaneous supply and extract operation, using only a single pipe for

easy installation.

The recovery of both latent heat and sensible heat ensures a comfortable internal environment as well as reducing heat losseshence saving both energy and costs. Perfect for new build or retrofit residential and commercial applications where there is aneed for ventilation to remove stale air without major heat loss.

Key Features

Low power consumption

Total heat exchange (sensible and latent)

Easy maintenance

Flexible and simple installation

Effective fresh air ventilation

Improved air quality and comfort

Efficient heat recovery - up to 84%

Low sound level

OUTDOOR UNITS

220-240v, 50Hz

Single

5

21

17

54

15.5

37.5

84

68

6.2

522

168

245

φ120

6

3

Pull Cord

220-240v, 50Hz

Single

5

21

17

54

15.5

37.5

84

68

6.2

522

168

245

φ120

6

3

External Wall Switch (Field Supply)

220-240v, 50Hz

Single

5.5

21

17

54

15.5

37.5

84

68

6.2

522

168

245

φ120

6

3

Wireless Remote Controller

VL-50S2 VL-50ES2 VL-50Sr2

ELECTRICAL POWER SUPPLY

PHASE

POWER CONSUMPTION (W) Low

High

AIRFLOW (m3/h) Low

High

SOUND PRESSURE LEVEL (dBA) Low

High

TEMPERATURE EXCHANGE EFFICIENCY (%) Low

High

WEIGHT (kg)

DIMENSIONS (mm) Width

Depth

Height

DUCT SIZE (mm)

FUSE RATING (BS88) - HRC (A)

MAINS CABLE NO. CORES

CONTROL

Freedom Heat Pumps - www.freedomhp.co.uk

Page 43: Heating and Ventilation Product Catalogue Info/Mitsubishi/2019_Heating... · EHPX-VM2C FTC5 Packaged Hydrobox for Ecodan Monobloc Units PUHZ-SW Split Air Source Heat Pumps EHST20(D)(C)-MHCW

Page 43 Heating and Ventilation Product Catalogue 2019

Front View Side View

Rear View

Product Dimensions VL-50S2/ES2/SR2

Freedom Heat Pumps - www.freedomhp.co.uk

Page 44: Heating and Ventilation Product Catalogue Info/Mitsubishi/2019_Heating... · EHPX-VM2C FTC5 Packaged Hydrobox for Ecodan Monobloc Units PUHZ-SW Split Air Source Heat Pumps EHST20(D)(C)-MHCW

Page 44 Heating and Ventilation Product Catalogue 2019

VL-100(E)U5-E

Wall Mounted Lossnay

The VL-100 units supply fresh air inside a room using simultaneous supply

and extract operation in an energy efficient manner.

The recovery of both latent heat and sensible heat ensures a comfortable internal environmentas well as reducing heat losses hence saving both energy and costs.

The compact unit with it’s simple installation makes it ideal for single room applicationssuch as small offices, bedrooms etc.

Effective fresh air ventilation with improved air quality

Reduces heating / cooling costs

Simple installation

Key Features

Notes: The VL-100U5-E includes a pull cord switch to control the unit. Also available as VL-100EU5-E which includes the option to fit a field supplied external wall switch

ELECTRICAL POWER SUPPLY

PHASE

POWER  CONSUMPTION (W) Low

High

AIRFLOW (m3/h) Low

High

SOUND PRESSURE LEVEL (dBA) Low

High

TEMPERATURE EXCHANGE EFFICIENCY (%) Low

High

WEIGHT (kg)

DIMENSIONS (mm) Width

Depth

Height

DUCT  SIZE (mm)

FUSE  RATING (BS88) - HRC (A)

MAINS  CABLE  No. Cores

CONTROL ON/OFF

WALL- MOUnTEd

220-240V, 50Hz

Single

17

34

61

106

27

38

79

72

7.5

620

200

265

2 x Ø75

6

3

Pull Cord

VL-100U5-E

220-240V, 50Hz

Single

17

34

61

106

27

38

79

72

7.5

620

200

265

2 x Ø75

6

3

VFC for External Wall Switch (Field Supply)

VL-100EU5-E

Freedom Heat Pumps - www.freedomhp.co.uk

Page 45: Heating and Ventilation Product Catalogue Info/Mitsubishi/2019_Heating... · EHPX-VM2C FTC5 Packaged Hydrobox for Ecodan Monobloc Units PUHZ-SW Split Air Source Heat Pumps EHST20(D)(C)-MHCW

Page 45 Heating and Ventilation Product Catalogue 2019

2

SHUTTER KNOB

W

SHUTTER KNOB

FRESH AIR SUPPLY 90 140

620

(CLOSED POSITION) (OPEN POSITION)

INDOOR AIR EXHAUST

M

Front View

Side ViewUpper View

EDGE OF MAIN UNIT 420

REQUIRE TO BE SECURED REQUIRE TO BE SECURED

ABLE)(ADJUST

(ADJU

STAB

LE)

AIR INTAKE HOLEø85 to ø90 WALL HOLE

40

108

119

95

2515

95.5

PIT

CH 20

X10=

200

265

13.5

238.5

183m

infro

m ne

ares

tob

struc

tion

233m

in

75

87

267.5

554

292

75(ADJUSTABLE)

MOUNTING HOLES36×ø6

530

360min from nearest obstruction

200(MIN)350(MAX)

360min620

AIR EXHAUST HOLEø85 to ø90 WALL HOLE

O

9725

POWER CORD HOLE

MOUNTING PLATE

Accessories

High efficiency filter for VL-100(E)U5-E

P-100HF5-E

High Efficiency Filters

Product Dimensions VL-100(E)U5-E

Unit: mm

226

12

FRONT PANEL (OPEN POSITION)

FRONT PANEL LOUVER (HORIZONTAL POSITION)

FRONT PANEL LOUVER (VERTICAL POSITION)

FRONT PANEL (CLOSED POSITION)

E

2

OUTE

R DI

A

OUTE

R DI

A

ø75×

2

ø79×

2

WALL THICKNESS

54200

5° ø150

106

50 to 550

22 17

Extension pipe for VL-100(E)U5-E

P-100P-E

Extension pipe joint for VL-100(E)U5-E

P-100PJ-E

Extension Pipe Kits

Freedom Heat Pumps - www.freedomhp.co.uk

Page 46: Heating and Ventilation Product Catalogue Info/Mitsubishi/2019_Heating... · EHPX-VM2C FTC5 Packaged Hydrobox for Ecodan Monobloc Units PUHZ-SW Split Air Source Heat Pumps EHST20(D)(C)-MHCW

Page 46 Heating and Ventilation Product Catalogue 2019

VL-220CZGV-EB

residential / LightCommercial Lossnay

The Lossnay VL-220 Mechanical Ventilation with Heat Recovery (MVHR) unit is

an energy efficient whole house ventilation solution which provides a clean,

fresh air supply to a home.

It simultaneously extracts stale air from the internal environment whilst recovering valuable heat energyto maximise efficiency and minimise energy use. Ideal for high humidity areas, the Lossnay VL-220 isalso suitable for small commercial properties.

Energy efficient whole house ventilation with heat recovery

Free summer cooling function

Dedicated remote controller

New Lossnay sensible only heat exchanger core

Key Features

220-240V/50Hz

32

ELECTRICAL POWER SUPPLY

WEIGHT (kg)

FAN  SPEED

RUNNING CURRENT (A)

INPUT  POWER (W)

AIRFLOW (m3/h)

AIRFLOW (l/s)

EXTERNAL  STATIC  PRESSURE (Pa)

TEMPERATURE EXCHANGE EFFICIENCY (%)

NOISE (dB)

DIMENSIONS (mm) Width

Depth

Height

MAXIMUM CURRENT (A)

1

0.11

8.5

65

18

13

86

14.0

2

0.18

18.5

120

33

44

85

19.0

3

0.29

35

165

46

84

84

25.0

4

0.60

80

220

64

164

82

31.0

MOdEL VL-220CZGV-EB

850

720

340

0.8

Freedom Heat Pumps - www.freedomhp.co.uk

Page 47: Heating and Ventilation Product Catalogue Info/Mitsubishi/2019_Heating... · EHPX-VM2C FTC5 Packaged Hydrobox for Ecodan Monobloc Units PUHZ-SW Split Air Source Heat Pumps EHST20(D)(C)-MHCW

Page 47 Heating and Ventilation Product Catalogue 2019

Front View

Upper View Left Side View Right Side View

Accessories

Lossnay remote controller for VL-220CZGV-EB

PZ-61DR-E

Lossnay simplified remote controller for

VL-220CZGV-EB

PZ-43SMF-E

Controllers

Lossnay medium efficiency filter for VL-220CZGV-EB

P-220EMF-E

Lossnay high efficiency filter for VL-220CZGV-EB

P-220SHF-E

Filters

Product Dimensions VL-220CZGV-EB

Freedom Heat Pumps - www.freedomhp.co.uk

Page 48: Heating and Ventilation Product Catalogue Info/Mitsubishi/2019_Heating... · EHPX-VM2C FTC5 Packaged Hydrobox for Ecodan Monobloc Units PUHZ-SW Split Air Source Heat Pumps EHST20(D)(C)-MHCW

Designed by Square Bear Ltd 01604 899099. Square Bear Ltd are committed to using FSC® certified paper and printers, wherever possible.

UNITED KINGDOM Mitsubishi Electric Europe Living Environment Systems Division

Travellers Lane, Hatfield, Hertfordshire, AL10 8XB, England

General Enquiries Telephone: 01707 282880 Fax: 01707 278881

IRELAND Mitsubishi Electric Europe Westgate Business Park, Ballymount, Dublin 24, Ireland

Telephone: Dublin (01) 419 8800 Fax: Dublin (01) 419 8890 International code: (003531)

Country of origin: United Kingdom – Japan – Thailand – Malaysia. ©Mitsubishi Electric Europe 2019. Mitsubishi and Mitsubishi Electric are trademarks of Mitsubishi Electric Europe B.V. The company reserves the right to make any variation in technical specification to the equipment described, or to withdraw or replace products without prior notification or public announcement. Mitsubishi Electric is constantly developing

and improving its products. All descriptions, illustrations, drawings and specifications in this publication present only general particulars and shall not form part of any contract. All goods are supplied subject to the Company’s General Conditions of Sale, a copy of which is available on request. Third-party product and brand names may be trademarks or registered trademarks of their respective owners.

Note: The fuse rating is for guidance only. Please refer to the relevant databook for detailed specification. It is the responsibility of a qualified electrician/electrical engineer to select the correct cable size and fuse rating based on current regulation and site specific conditions. Mitsubishi Electric’s air-conditioning equipment and heat pump systems contain a fluorinated greenhouse gas, R410A (GWP:2088),

R32 (GWP:675), R407C (GWP:1774) or R134a (GWP:1430). *These GWP values are based on Regulation (EU) No 517/2014 from IPCC 4th edition. In case of Regulation (EU) No.626/2011 from IPCC 3rd edition, these are as follows. R410A (GWP:1975), R32 (GWP: 550), R407C (GWP:1650) or R134a (GWP:1300).

015 015

Telephone: 01707 282880

email: [email protected]

web: www.heating.mitsubishielectric.co.uk

Freedom Heat Pumps - www.freedomhp.co.uk