20
Product range overview Heating systems Industrial systems Refrigeration systems

Heating systems Industrial systems Refrigeration systemsmedia.brintex.com/Occurrence/174/Brochure/4755/brochure.pdf · VITOLIGNO 250-S Firewood boiler Type SH20 For manual loading

  • Upload
    others

  • View
    7

  • Download
    0

Embed Size (px)

Citation preview

Page 1: Heating systems Industrial systems Refrigeration systemsmedia.brintex.com/Occurrence/174/Brochure/4755/brochure.pdf · VITOLIGNO 250-S Firewood boiler Type SH20 For manual loading

Product range overview

Heating systemsIndustrial systems

Refrigeration systems

Page 2: Heating systems Industrial systems Refrigeration systemsmedia.brintex.com/Occurrence/174/Brochure/4755/brochure.pdf · VITOLIGNO 250-S Firewood boiler Type SH20 For manual loading

Product range overview

Page 3: Heating systems Industrial systems Refrigeration systemsmedia.brintex.com/Occurrence/174/Brochure/4755/brochure.pdf · VITOLIGNO 250-S Firewood boiler Type SH20 For manual loading

2/3

The complete product range from Viessmann offers solutions for all application areas and all energy types. With high energy efficiency we help to save heating costs and provide the right decision in ecological terms.

The company has been supplying this for decades, which includes; heating systems for oil, gas and biomass, as well as solar systems and heat pumps.

All products from Viessmann achieve the targets set by the EU regarding environmental pollution and emission reductions. The best possible environmental protection and the maximum conservation of resources are traditional Viessmann values. For this reason the company uses the best available technology to generate heat and electricity.

A Viessmann solution for all energy types and applications

Viessmann offers state-of-the-art technology and sets high standards

Individual and efficient solutionsViessmann has the right heating system for every need; wall-hung and floor-standing, individually combinable, future-proof and economical. Whether for one or two-family houses, large residential buildings, or for trade and district heating schemes, they are ideal for both retrofit projects or new build developments.

The product range includes:

� Boilers for oil or gas � Adsorption and hybrid devices � Heat pumps � Wood heating systems � Power generating heating systems � Solar thermal energy � Photovoltaics � Combined heat and power plants � Accessories

Viessmann is highly specialised in these market segments. Compared to other specialists in the market, Viessmann has a decisive advantage: providing expertise on many systems and guaranteeing energy neutral consulting at a high level.

Page 4: Heating systems Industrial systems Refrigeration systemsmedia.brintex.com/Occurrence/174/Brochure/4755/brochure.pdf · VITOLIGNO 250-S Firewood boiler Type SH20 For manual loading

Oil condensing boilers, 20.2 up to 107.3 kWOil / gas condensing heat exchanger, 101 up to 545 kWGas condensing wall unit boilers 2.4 up to 150 kW

Domestic gas condensing boilersVITODENS 200-W Gas condensing wall unit

Type B2HB (System)19 / 26 / 30 / 35 kW Type B2KB (Combi) 26 / 30 / 35 kWStandard usage: up to 98 % (Hs)/109 % (Hi)Energy efficiency class: AEnergy efficiency class: A

VITODENS 222-F Gas condensing unit with DHW cylinderType B2TB (with DHW cylinder)19 / 26 / 35 kWDHW cylinder: 100 / 130 LitreStandard usage: up to 98 % (Hs)/109 % (Hi)Energy efficiency class: AEnergy efficiency class: A (Pivoting profile XL)

VITODENS 242-F Gas condensing unit with DHW cylinderType B2UB 19 / 26 kW DHW cylinder: 170 LitreStandard usage: up to 98 % (Hs)/109 % (Hi) Energy efficiency class: AEnergy efficiency class: A

VITODENS 100-W Gas condensing wall unitType B1HC (System)19 / 26 / 30 / 35 kWType B1KC (Combi) 26 / 30 / 35 kWType WB1B (Open Vent)13 / 16 / 19 / 26 / 35 kWStandard usage: up to 98 % (Hs)/109 % (Hi)Energy efficiency class: AEnergy efficiency class: A

VITODENS 111-W Gas condensing unit with DHW cylinderType B1LD26 / 35 kWDHW cylinder: 46 LitreStandard usage: up to 98 % (Hs)/109 % (Hi) Energy efficiency class: AEnergy efficiency class: A

VITODENS 050-W Gas condensing wall unitType BPJD (Combi)29 / 35 kWEnergy efficiency class: AEnergy efficiency class: A

Page 5: Heating systems Industrial systems Refrigeration systemsmedia.brintex.com/Occurrence/174/Brochure/4755/brochure.pdf · VITOLIGNO 250-S Firewood boiler Type SH20 For manual loading

4/5

Oil condensing boilers

Oil / gas condensing heat exchanger

Gas condensing boilers

Oil condensing boilersVITORONDENS 200-T Oil condensing boiler

Type BR2A20.2 / 24.6 / 28.9 / 35.4 / 42.8 / 53.7 kWTyp J2RA67.6 / 85.8 / 107.3 kWStandard usage: up to 97 % (Hs)/103 % (Hi)Energy efficiency class: A

VITORADIAL 300-T Low temperature boiler withoil condensing heat exchangerType VR3 Three-pass boiler with multi-shell convection heating surfaces and downstream Inox-Radial heat exchanger101 / 129 / 157 / 201 / 263 / 335 / 425 / 545 kWStandard usage for operation with heating oil: up to 97 % (Hs)/103 % (Hi)

Commercial gas condensing boilersVITODENS 200-W Gas condensing wall unit

Type B2HA49 / 60 / 80 / 99 / 120 / 150Cascade connection with up to six wall units from 49 kW up to 900 kWStandard usage: up to 98 % (Hs)/109 % (Hi)Energy efficiency class: A (up to 60 kW)

Page 6: Heating systems Industrial systems Refrigeration systemsmedia.brintex.com/Occurrence/174/Brochure/4755/brochure.pdf · VITOLIGNO 250-S Firewood boiler Type SH20 For manual loading

Gas condensing boilers, 2.6 up to 1400 kW

Gas condensing boilersVITOCROSSAL 300 Gas condensing floorstanding boiler

Type CM329 – 87 / 38 – 115 / 47 – 142 kWStandard usage: up to 98 % (Hs)/109 % (Hi)

VITOCROSSAL 300 Gas condensing floorstanding boilerType CT3U135 – 400 / 168 – 500 / 209 – 630 kWStandard usage: up to 98 % (Hs)/109 % (Hi)

VITOCROSSAL 300 Gas condensing floorstanding boilerType CT3B187 / 248 / 314 / 408 / 508 / 635 kWStandard usage: up to 98 % (Hs)/109 % (Hi)

VITOCROSSAL 300 Gas condensing floorstanding boilerType CR3B787 / 978 / 1100 / 1400 kWStandard usage: up to 98 % (Hs)/109 % (Hi)

Page 7: Heating systems Industrial systems Refrigeration systemsmedia.brintex.com/Occurrence/174/Brochure/4755/brochure.pdf · VITOLIGNO 250-S Firewood boiler Type SH20 For manual loading

6/7

Gas condensing boilers

VITOCROSSAL 200 Gas condensing floorstanding boilerType CM2400 / 500 / 620 kWStandard usage: up to 98 % (Hs)/109 % (Hi)

VITOCROSSAL 200 Gas condensing floorstanding boilerType CM2B29 – 87 / 38 – 115 / 47 – 142 / 62 – 186 / 82 – 246 / 104 – 311 kWStandard usage: up to 98 % (Hs)/109 % (Hi)

VITOCROSSAL 100 Gas condensing floorstanding boilerType CI180 / 120 / 160 / 200 / 240 / 280 / 320 kWStandard usage: up to 98 % (Hs)/109 % (Hi)Cascade as a double boiler unit: 240 / 320 / 400 / 480 / 560 / 640

Page 8: Heating systems Industrial systems Refrigeration systemsmedia.brintex.com/Occurrence/174/Brochure/4755/brochure.pdf · VITOLIGNO 250-S Firewood boiler Type SH20 For manual loading

Oil / gas low-temperature boilers, 405 up to 2000 kWLow temperature hot water generators, 0.65 up to 20 MW

Oil / gas low-temperature boilersVITOPLEX 300 Oil / gas low-temperature boiler

Type TX3A Three-pass boiler with multi-shell convection heating surfaces 405 / 500 / 620 / 780 / 1000 / 1250 / 1600 / 2000 kWStandard usage for operation with heating oil: up to 90 % (Hs)/96 % (Hi)

VITOPLEX 200 Oil / gas low-temperature boilerType SX2A Three-pass boiler 440 / 560 / 700 / 900 / 1100 / 1300 / 1600 / 1950 kWStandard usage for operation with heating oil: up to 90 % (Hs)/96 % (Hi)

VITOROND 200 Oil / gas low-temperature boilerType VD2A Three-pass boiler in cast segment design440 / 500 / 560 / 630 / 700 / 780 / 860 / 950 / 1080 kWStandard usage for operation with heating oil: up to 88 % (Hs)/94 % (Hi)

Low temperature hot water generatorsVITOMAX 300-LW Low temperature hot water generator

for low-NOx operationPermissible flow temperature up to 110 °C (120 °C single sampling)Type M82A: 2.1 – 6 MWType M84A: 8 – 20 MWPermissible operating pressure at: max. 6, 10, 16 barBoiler efficiency: 92 %

VITOMAX 200-LW Low temperature hot water generatorPermissible flow temperature up to 110 °C (120 °C single sampling)Type M62C: 2.3 – 8.8 MWPermissible operating pressure at: max. 6, 10, 16 barType M64A: 10 – 20 MWPermissible operating pressure at: max. 6, 10, 16 barBoiler efficiency: 92 %

VITOMAX 100-LW Low temperature hot water generatorPermissible flow temperature up to 110 °CType M148: 0.65 – 6 MWPermissible operating pressure at: max. 6, 10, barBoiler efficiency: 91,5 %

Page 9: Heating systems Industrial systems Refrigeration systemsmedia.brintex.com/Occurrence/174/Brochure/4755/brochure.pdf · VITOLIGNO 250-S Firewood boiler Type SH20 For manual loading

8/9

Oil / gas low-temperature boilers

Low temperature hot water generators

Low pressure steam boilerVITOPLEX 100-LS Oil/gas low pressure steam boiler

Type SXD 0.26 to 2.2 t/h0.5 (1) barEfficiency: 91 %

High pressure steam boilersVITOMAX 300-HS High pressure steam boiler

Up to 25 bar (28,30 bar on request)Type M93A: 1 to 4 t/hType M95A: 5 to 26 t/hEfficiency: over 95.5%(with internal economiser)

VITOMAX 200-HS High pressure steam boilerUp to 25 bar (28,30 bar on request)Type M73A: 0.5 to 4 t/hType M75A: 5 to 26 t/hEfficiency: over 95.5%(with internal economiser)

VITOMAX 100-HS High pressure steam boilerUp to 16 barType M33A: 1 to 6.4 t/hEfficiency: 92%(with economiser)

Waste heat boilersVITOMAX 200-RWVITOMAX 200-RS

Waste heat boiler for generating hot waterWaste heat boiler for generating steam

Page 10: Heating systems Industrial systems Refrigeration systemsmedia.brintex.com/Occurrence/174/Brochure/4755/brochure.pdf · VITOLIGNO 250-S Firewood boiler Type SH20 For manual loading

Combined heat and power unitsVITOBLOC 200 Module EM-6/15

Capacity: 6 kWel, 14.9 kWth

Total efficiency (when used with natural gas): 94 %(Hi)

Module EM-9/20Capacity: 8,5 kWel, 20.1 kWth

Total efficiency (when used with natural gas): 95 %(Hi) 3-cylinder gas-Otto engine three-phase synchronous generatorEnergy efficiency class: A++

Fuel: natural gas and LPG

VITOBLOC 200 Module EM-20/39Capacity: 20 kWel, 39 kWth Total efficiency (when used with natural gas): 94.9 %(Hi)4-cylinder gas spark-ignition engine three-phase synchronous generatorEnergy efficiency class: A++

Fuel: natural gas and LPG

VITOBLOC 200 Module EM-50/81Capacity: 50 kWel, 81 kWth

Overall efficiency: 90.3 %(Hi) 4-cylinder gas petrol engine three-phase synchronous generator

Module EM-70/115Capacity: 70 kWel, 115 kWth

Overall efficiency: 90.7 %(Hi) Reliable motors with three-way catalyst

Module EM-140/207Capacity: 140 kWel, 207 kWth

Overall efficiency: 90.4 %(Hi) Reliable motors with three-way catalyst

Fuel: Natural gas

Combined heat and power, 6 up to 530 kWel, 14.9 up to 660 kWth

Page 11: Heating systems Industrial systems Refrigeration systemsmedia.brintex.com/Occurrence/174/Brochure/4755/brochure.pdf · VITOLIGNO 250-S Firewood boiler Type SH20 For manual loading

10/11

VITOBLOC 200 Module EM-199/263Capacity: 199 kWel, 263 + 20 kWth

Reliable motors with three-way catalyst Overall efficiency: 89.6 %(Hi)

Module EM-199/293Capacity: 199 kWel, 293 kWth

Reliable motors with three-way catalyst Overall efficiency: 89.6 %(Hi)

Module EM-238/363Capacity: 238 kWel, 363 kWth

Reliable motors with three-way catalyst Overall efficiency: 90.1 %(Hi)

Fuel: Natural gas

VITOBLOC 200 Module EM-363/498Capacity: 363 kWel, 498 kWth

Overall efficiency: 92.8 %(Hi)

Module EM-401/549Capacity: 401 kWel, 549 + 20 kWth

Overall efficiency: 92.8 %(Hi)

Module EM-530/660Capacity: 530 kWel, 660 + 38 kWth

Overall efficiency: 91.5 %(Hi)

Fuel: Natural gasRigid motors with oxidation catalyst

Combined heat and power

Domestic fuel cell unitVITOVALOR 300-P Capacity: 0.75 kW el, 1 kW th

Peak load boiler output: 19 kWPeak load power output: 15 kWhBuffer cylinder capacity: 170 litresDHW cylinder capacity: 46 litres

Page 12: Heating systems Industrial systems Refrigeration systemsmedia.brintex.com/Occurrence/174/Brochure/4755/brochure.pdf · VITOLIGNO 250-S Firewood boiler Type SH20 For manual loading

Biomass boilersVITOLIGNO 300-C Pellet boiler

Type VL3C2,4 – 8, 2,4 – 12, 6 – 18, 8 – 24, 11 – 32, 13 – 40, 16 – 48, 18 – 60, 21 – 70, 24 – 80, 30 – 99, 30 – 101 kWEfficiency: up to 96 %Single phase auger

VITOLIGNO 250-S Firewood boilerType SH20For manual loading with logs, wooden briquettes as well as wood remnantsFilling space 550 mm: 40, 50, 60 and 75 kWFilling space 1080 mm: 85, 100, 120 and 170 kWEfficiency: up to 93.2 %

VITOLIGNO 250-F Biomass boilerFor manual loading with logs, wooden briquettes, wood pieces and loose wood residues. Also available for automatic loading with wood pellets and chips35 – 49, 52 – 75, 70 – 100 kW Efficiency: up to 92 %

Biomass boilers, 2.4 up to 170 kWBiomass systems, 150 up to 1250 kW

Page 13: Heating systems Industrial systems Refrigeration systemsmedia.brintex.com/Occurrence/174/Brochure/4755/brochure.pdf · VITOLIGNO 250-S Firewood boiler Type SH20 For manual loading

12/13

Biomass systemsVITOLIGNO 300-H Boiler for pellets and wood chips

Type VH3For automatic loading with pellets and wood chips15 – 50, 18 – 60, 24 – 80, 30 – 99, 30 – 101 kWEfficiency: up to 94.9 %

VITOFLEX 300-RF Wood heating boiler with rotary firingFor wood pellets, wood chips and wood shavingsWater content: max. 35 %150, 220, 300, 400, 540 kWPermissible flow temperature: up to 100 °CPermissible operating pressure: 3 barEfficiency: up to 94 %

VITOFLEX 300-UF Boiler for automatic feeding with underfeed firingFor wood pellets, wood chips and wood remnantsWater content: max. 50 %390, 530, 720, 950, 1250 kWPermissible flow temperature: up to 100 °CPermissible operating pressure: 6 barEfficiency: up to 92 %

Biomass boilers

Biomass systems

Page 14: Heating systems Industrial systems Refrigeration systemsmedia.brintex.com/Occurrence/174/Brochure/4755/brochure.pdf · VITOLIGNO 250-S Firewood boiler Type SH20 For manual loading

Ground source heat pumpsVITOCAL 350-G Single stage heat pump (master)

Brine / water heat pump Type BW 351.B Output: 20.5 / 28.7 / 32.7 / 42.3 kWEnergy efficiency class: A++ / A++ Water / water heat pump Type BW 351.B Output: 25.4 / 34.7 / 42.2 / 52.3 kW

VITOCAL 350-G Two-stage heat pump (master / slave)as second stage (slave), without own regulationBrine / water heat pump Type BWS 351.B Output: 20.5 / 28.7 / 32.7 / 42.3 kWEnergy efficiency class: A++ / A++

Water / water heat pump Type BWS 351.B Output: 25.4 / 34.7 / 42.2 / 52.3 kW

VITOCAL 300-G Single stage heat pump (master)Brine / water heat pump Type BW/BWC 301.B Output: 5.7 / 7.6 / 10.4 / 13.0 / 17.2 kWEnergy efficiency class: A++ / A++

Water / water heat pump Type BW/BWC 301.B Output: 7.5 / 10.2 / 13.5 / 16.9 / 22.6 kW

VITOCAL 300-G Two-stage heat pump (master / slave)as second stage (slave), without own regulationBrine / water heat pump Type BWS 301.B Output: 5.7 / 7.6 / 10.4 / 13.0 / 17.2 kWEnergy efficiency class: A++ / A++

Water / water heat pump Type BWS 301.B Output: 7.5 / 10.2 / 13.5 / 16.9 / 22.6 kW

VITOCAL 300-G Single stage heat pump (master)Brine / water heat pump Type BW 301.A Output: 21.2 / 28.8 / 42.8 kWEnergy efficiency class: A++ / A++

Water / water heat pump Type BW 301.A Output: 28.1 / 37.1 / 58.9 kW

Heat pumps, 5.7 up to 42.8 kW

Page 15: Heating systems Industrial systems Refrigeration systemsmedia.brintex.com/Occurrence/174/Brochure/4755/brochure.pdf · VITOLIGNO 250-S Firewood boiler Type SH20 For manual loading

14/15

VITOCAL 300-G Two-stage heat pump (master / slave)as second stage (slave), without own regulationBrine / water heat pump Type BWS 301.A Output: 21.2 / 28.8 / 42.8 kWEnergy efficiency class: A++ / A++

Water / water heat pump: Type BWS 301.A Output: 28.1 / 37.1 / 58.9 kW

VITOCAL 242-G Compact heat pump Brine / water Type BWT 241.A Output: 6 / 7.8 / 10.1 kWDHW cylinder capacity: 220 Litres with solar connectivityEnergy efficiency class: A++ / A++ , A (Draw off profile XL)

VITOCAL 222-G Compact heat pump Brine / water Type BWT 221.AOutput: 6 / 7.8 / 10.1 kWDHW cylinder capacity: 170 LitresEnergy efficiency class: A++ / A++ , A (Draw off profile XL)

VITOCAL 200-G Brine / water heat pump Type BWC.M 201.AOutput: 5.6 / 7.5 / 9.7 kWEnergy efficiency class: A++ / A++

Heat pumps

Page 16: Heating systems Industrial systems Refrigeration systemsmedia.brintex.com/Occurrence/174/Brochure/4755/brochure.pdf · VITOLIGNO 250-S Firewood boiler Type SH20 For manual loading

Air source heat pumpsVITOCAL 350-A Air Water heat pump

Indoor or outdoor installationType AWHI/AWHO 351.A Output: 10.6 / 14.5 / 18.5 kWEnergy efficiency class: A++ / A+ (10,6 kW), A+ / A+ (14.5 / 18.5 kW)

VITOCAL 300-A Air Water heat pumpIndoor or outdoor installationType: AWCI/MAC AWO/MACOutput: 3 - 8.6 kW Energy efficiency class: A++ / A+

VITOCAL 300-A Air Water heat pumpOutdoor settingType AWO-AC 301.B Output: 7.0 / 8.5 kWEnergy efficiency class: A++ / A++

Heat pumps, 5.6 up to 50.0 kWAir source heat pumps, 3.0 up to 18.5 kWSplit heat pumps, 1.7 up to 11.3 kW

Split air / water heat pumpsVITOCAL 222-S Split air / water heat pumps compact unit

Type AWT-AC 221.A Output: 3.0 / 4.05 / 5.6 / 7.7 / 10.6 kWDHW cylinder capacity: 170 LitresEnergy efficiency class: A++ / A+ (Type AWT-AC 221.A)

A (Draw off profile L at 3 – 5.6 kW), (Draw off profile XL at 7.7 – 10.6 kW

VITOCAL 200-S Split air / water heat pumpType AWB/AWB-AC 201.B Output: 3.0 / 4.05 / 5.6 / 7.7 kWEnergy efficiency class: A++ / A+ (Type AWB/AWB-AC 201.B),

Page 17: Heating systems Industrial systems Refrigeration systemsmedia.brintex.com/Occurrence/174/Brochure/4755/brochure.pdf · VITOLIGNO 250-S Firewood boiler Type SH20 For manual loading

16/17Large heat pumps, 27.2 up to 2000 kW

Large heat pumpsVITOCAL 300-G PRO Single and two-stage brine / water heat pump

With electric drive for heating / cooling and DHW heatingIn monovalent or bivalent heating systemsOutput: 60 / 83 / 87 / 107 / 111 / 135 / 173 / 222 kWMax. Flow temperature: up to 60 °C

VITOCAL 300-W PRO Single and two-stage water / water heat pumpWith electric drive for heating / cooling and DHW heatingIn monovalent or bivalent heating systemsOutput: 112 / 116 / 145 / 160 / 190 / 240 / 290 kWMax. Flow temperature: up to 60 °C

Large heat pumps

Page 18: Heating systems Industrial systems Refrigeration systemsmedia.brintex.com/Occurrence/174/Brochure/4755/brochure.pdf · VITOLIGNO 250-S Firewood boiler Type SH20 For manual loading

Solar thermal flat plate collectorsVITOSOL 200-FM Flat collector

Powerful flat collector with automatic temperature cut-offThermProtect for a steamless and intrinsically safe solar systemFor in-roof mountingType SV2F/SH2FFor on-roof and flat roof mountingType SV2G/SH2GAbsorber surface: 2,3 m2

For in-roof mounting

VITOSOL 100-FM Flat-plate collectorsType SVKF / SVKGAbsorber surface: 2.02 m2

For on-roof installation - SVKFFor in-roof installation - SVKG

VITOSOL 100-FM Flat collectorPowerful flat collector with automatic temperature cut-offThermProtect for a steamless and intrinsically safe solar system For on-roof and flat roof mountingType SV1F/SH1FAbsorber surface: 2,3 m2

Vacuum tube collectorsVITOSOL 300-T Vacuum tube collector

Heatpipe principleType SP3BAbsorber area: 1,51 and 3,03 m2

VITOSOL 200-T Vacuum tube collectorHeatpipe principle Type SP2AAbsorber area: 1,26 / 1,51 / 3,03 m2

VITOSOL 200-T Vacuum tube collectorHeatpipe principle For horizontal or flat roof mountingType SPEAbsorber area: 1,63 and 3,26 m2

Solar thermalSolar photovoltaicCylinders

Page 19: Heating systems Industrial systems Refrigeration systemsmedia.brintex.com/Occurrence/174/Brochure/4755/brochure.pdf · VITOLIGNO 250-S Firewood boiler Type SH20 For manual loading

18/19

Solar thermal

Solar photovoltaic

Cylinders

Photovoltaic modulesVITOVOLT 300 Mono crystalline photovoltaic modules

With black anodised frame and dark Tedlar foil Module output: up to 285 Wp

VITOVOLT 300 Polycrystalline photovoltaic modulesModule output: up to 270 Wp For high snow and wind loads

CylindersCylindersSingle coil cylinders from 90 to 500 litresDual coil cylinders from 210 to 500 litresBuffer cylinders from 46 to 2,000 litres

Page 20: Heating systems Industrial systems Refrigeration systemsmedia.brintex.com/Occurrence/174/Brochure/4755/brochure.pdf · VITOLIGNO 250-S Firewood boiler Type SH20 For manual loading

Viessmann LimitedHortonwood 30, TelfordShropshire, TF1 7YPTel: 01952 675000Fax: 01952 675040www.viessmann.co.uk

9449 592 - 6 GB 02/2017

Copyright Viessmann

Duplication and alternative use only with prior written consent.

Subject to technical modifications.

Contact us

Domestic salesTelephone 01952 675010Fax 01952 678600Email [email protected]

Commercial salesTelephone 01952 675090Fax 01952 678600Email [email protected]

Technical helplineTelephone 01952 675070Email [email protected]

After salesTelephone 01952 675060Email [email protected]

SparesTelephone 01952 675013Email [email protected]