40
Heavy-duty systems System information

Heavy-duty systems

  • Upload
    others

  • View
    1

  • Download
    0

Embed Size (px)

Citation preview

Page 1: Heavy-duty systems

08 U

FS S

chw

erla

stsy

stem

e 20

16_m

it P

rodu

kte

/ en

/ 11/

05/2

017

(LLE

xpor

t_04

557)

/ 11

/05/

2017

Title page

1

Heavy-duty systems

 

 

System information

 

 

Page 2: Heavy-duty systems

08 U

FS S

chw

erla

stsy

stem

e 20

16_m

it P

rodu

kte

/ en

/ 11/

05/2

017

(LLE

xpor

t_04

557)

/ 11

/05/

2017

 

 

Heavy-duty systems

Heavy-duty systems reliably supply areas with highload requirements with power, data and multimediatechnology via the floor. Car dealerships, museums,airports, stations or hotels are typical areas of appli-cation. The construction and the material thickness isspecially matched to the high load requirements. Withthe heavy-duty system, Ackermann made by OBOguarantees a particularly robust, safe and long-lastinginstallation solution.

 

08 U

FS S

chw

erla

stsy

stem

e 20

16_m

it P

rodu

kte

/ en

/ 11/

05/2

017

(LLE

xpor

t_04

557)

/ 11

/05/

2017

2

Page 3: Heavy-duty systems

08 U

FS S

chw

erla

stsy

stem

e 20

16_m

it P

rodu

kte

/ en

/ 11/

05/2

017

(LLE

xpor

t_04

557)

/ 11

/05/

2017

Heavy-duty competence

Ackermann made by OBO has developed the specialheavy-duty solutions for underfloor installations inclose consultation with planners and architects.Standard products, such as the EÜK screed-coveredduct system or the height-adjustable cassettes, formthe basis of the development.

An internal company testing standard ensures thehighest quality and the highest load capacity: Its re-quirements go beyond the requirements of DIN EN50085-2-2. The comprehensive heavy-duty systemfrom Ackermann made by OBO is suitable for screed-covered installation in dry and wet-cleaned floors.

 

 

 

08 U

FS S

chw

erla

stsy

stem

e 20

16_m

it P

rodu

kte

/ en

/ 11/

05/2

017

(LLE

xpor

t_04

557)

/ 11

/05/

2017

3

Page 4: Heavy-duty systems

OBO testing standard

 

DIN EN 50085-2-2 specifies the load requirements forelectrical installation systems. According to this stand-ard, cassettes may only bend by a maximum of 6 mmwhen subjected to a load. However, with harder floorcoverings, such as stone or tiles, bending of 6  mmwill lead to breakage. For this reason, OBO has in-creased its internal quality criteria and goes a stepfurther with the OBO testing standard: The maximumbend for heavy-duty systems was reduced from 6 mmto 2  mm. The tests according to the OBO testingstandard take place in the company's own BET TestCentre.

Heavy load testing

Tested heavy-duty system components:• Underfloor junction and branch box of size 350-3• Heavy-duty support, heavy-duty mounting lid• Floor covering, tile, 20 mm• Cassette RKF2 SL2 V3 35

1 Bend to DIN EN 500085-2-2: 6 mm

2 Bend to OBO testing standard: 2 mm

3 Measured bend, OBO heavy-duty system 

Bend [mm]

Load [kN]

08 U

FS S

chw

erla

stsy

stem

e 20

16_m

it P

rodu

kte

/ en

/ 11/

05/2

017

(LLE

xpor

t_04

557)

/ 11

/05/

2017

4

Page 5: Heavy-duty systems

08 U

FS S

chw

erla

stsy

stem

e 20

16_m

it P

rodu

kte

/ en

/ 11/

05/2

017

(LLE

xpor

t_04

557)

/ 11

/05/

2017

 

OBO heavy-duty classes

ClassificationDIN EN 50085-2-2 divides the load capacities of elec-trical installation duct systems into two classes.The classifications rate the articles according to resist-ance to vertical loads that act over a small (6.102) orlarge (6.103) surface area. The 6.103 classificationand the test results from the BET Test Centre servedas a basis for the development of the internal OBOclassification into heavy-duty classes SL1 and SL2.Products of heavy-duty class SL1 are suitable forloads of up to 10 kN, whilst products of heavy-dutyclass SL2 are even suitable for loads of up to 20 kN.The maximum bending for both heavy-duty classes is2 mm.

Class 6.103 according to DIN EN 50085-2-2

Classification* Load in N

6.103.1 2,000

6.103.2 3,000

6.103.3 5,000

6.103.4 10,000

6.103.5 15,000* The OBO heavy-duty classes were developed based on Class 6.103. 

Classification according to the OBO testing stand-ard

OBO heavy load class Load in N

SL 1 10,000

SL 2 20,000 

08 U

FS S

chw

erla

stsy

stem

e 20

16_m

it P

rodu

kte

/ en

/ 11/

05/2

017

(LLE

xpor

t_04

557)

/ 11

/05/

2017

5

Page 6: Heavy-duty systems

 

 

The screed-covered solution

The screed-covered heavy-duty solution consists ofsix system components: The underfloor ducts, under-floor sockets, heavy-duty supports, heavy-duty mount-ing lids, height adjustment units and heavy-duty cas-settes. The 2 or 3-compartment underfloor ducts areused for cable routing and can easily be connected tothe prepared installation openings of the underfloorsockets. The underfloor sockets permit the installationof heavy-duty cassettes for inspection purposes or forthe mounting of installation accessories such assockets, data or multimedia technology. The heavy-duty supports and the special heavy-duty mounting lidprovide the necessary stability. The heavy-duty cas-settes are inserted in the heavy-duty mounting lid,allowing access to the installed installation devices.

Underfloor junction and branch box

The underfloor sockets of the nominal sizes 250 and350 must have a non-positive connection to thescreed. To avoid a reduction in the load capacity anddamage to the floor covering, no edge insulationstrips can be laid around the underfloor junction andbranch box.

08 U

FS S

chw

erla

stsy

stem

e 20

16_m

it P

rodu

kte

/ en

/ 11/

05/2

017

(LLE

xpor

t_04

557)

/ 11

/05/

2017

6

Page 7: Heavy-duty systems

08 U

FS S

chw

erla

stsy

stem

e 20

16_m

it P

rodu

kte

/ en

/ 11/

05/2

017

(LLE

xpor

t_04

557)

/ 11

/05/

2017

 

 

 

 

Heavy-duty cassettes

Heavy-duty cassettes are suitable for creating inspec-tion openings or for the installation of devices in areaswith high load requirements. The cassettes are ad-equately dimensioned for absorbing traffic loads andare rated for individual static loads up to 10 kN (SL1)or 20 kN (SL2). The GRAF9 service outlet is availablefor smaller loads up to 7.5 kN.

Heavy-duty mounting lid

The heavy-duty mounting lid is selected according tothe appropriate heavy-duty cassette. The height ad-justment units enable the screed-flush height adjust-ment of the heavy-duty mounting lid and are to beordered separately.

Heavy-duty supports

Heavy-duty supports are additional expansion partsfor underfloor sockets and increase the load capacity.The supports are inserted in the corner areas of theunderfloor box and are tensioned under the socketframe.

Ducts

The screed-covered ducts are only subjected to loadsduring the mounting period. Before screed laying, theducts are classified with a load capacity of 750 N ac-cording to DIN EN 50085-2-2. After screed laying, noloads impact on the ducts, as the screed accepts theloads as a static layer. For this reason, underfloorducts from the standard product range can also beused in areas with high load requirements. 2 and 3-compartment underfloor ducts from the EÜK screed-covered duct system are available.

08 U

FS S

chw

erla

stsy

stem

e 20

16_m

it P

rodu

kte

/ en

/ 11/

05/2

017

(LLE

xpor

t_04

557)

/ 11

/05/

2017

7

Page 8: Heavy-duty systems

 

Overview of heavy-duty systemsLoad capacity

Device installation unitsSelection according to• Load requirement• Floor covering thickness• Functional method• Installation capacity

Cassettes for cable outlets and inspection purposes protect theelectrical installation in the floor against water penetration. Allheavy-duty solutions guarantee moisture protection according toDIN EN 50085-2-2 and are therefore approved for wet-cleanedfloors indoors.

Heavy-duty mounting lidSelection according to• The shape of the selected service outlet

or the cassette (nominal size)• Screed height

With heavy-duty frame cassettes, a mounting set, not a mount-ing lid, must be used for the installation of installation devices.

Height adjustment unitsSelection according to• Screed height

Heavy-duty supports for underfloor socketSelection according to• Screed height

Underfloor socket (UZD)Selection according to• Screed height• Shape of the cassette and the heavy-duty mounting lid• Duct width

DuctsSelection according to• Cable volume

7.5 kN

Service outlet

Heavy-duty mounting lid

Height adjustment units

Heavy-duty support

Underfloor socket, nominal size350

08 U

FS S

chw

erla

stsy

stem

e 20

16_m

it P

rodu

kte

/ en

/ 11/

05/2

017

(LLE

xpor

t_04

557)

/ 11

/05/

2017

8

Page 9: Heavy-duty systems

08 U

FS S

chw

erla

stsy

stem

e 20

16_m

it P

rodu

kte

/ en

/ 11/

05/2

017

(LLE

xpor

t_04

557)

/ 11

/05/

2017

10 kNSL1

20 kNSL2

10 kNSL1

20 kNSL2

Square heavy-duty cassettes Round heavy-duty cassettes Heavy-duty frame cassettes

Heavy-duty mounting lid Heavy-duty mounting lid Mounting set

Height adjustment units Height adjustment units

Heavy-duty support

Underfloor socket, nominal size 250 and 350

Trunking in various widths, 2-com-partment and 3-compartment

08 U

FS S

chw

erla

stsy

stem

e 20

16_m

it P

rodu

kte

/ en

/ 11/

05/2

017

(LLE

xpor

t_04

557)

/ 11

/05/

2017

9

Page 10: Heavy-duty systems

 

Installation and floor cut-out dimensions

Various installation and floor cut-out dimensions mustbe taken into account for the mounting of height-ad-justable cassettes and the application of floor cover-ings in the cassette lids.

08 U

FS S

chw

erla

stsy

stem

e 20

16_m

it P

rodu

kte

/ en

/ 11/

05/2

017

(LLE

xpor

t_04

557)

/ 11

/05/

2017

10

Page 11: Heavy-duty systems

08 U

FS S

chw

erla

stsy

stem

e 20

16_m

it P

rodu

kte

/ en

/ 11/

05/2

017

(LLE

xpor

t_04

557)

/ 11

/05/

2017

 

 

Frame height for the floor covering in the lid(red dimensions)The frame height data relates to the maximum floorcovering thickness, including adhesive. The cassettesare available in various frame heights.

 

Floor cut-out for the installation of cassettes(blue dimensions)The dimensions for the floor cut-out should be con-sidered as target dimensions for correct installation ofthe cassette in the floor. They are only generally re-quired for the floor cut-out in system floors. The EÜKscreed-covered duct system or the OKA open trunk-ing system offer prefabricated mounting lids withmatching installation openings.

 

Internal dimension of the lid to determine the floorcovering cut-out (black dimensions)The dimension data relates to the internal dimensionof the cassette lid and is used to calculate the floorcovering cut-out. Depending on the type of floorcovering, appropriate reductions should be taken intoaccount, e.g. for expansion gaps.

 

Minimum floor structure height(raw concrete ceiling to finished floor)The dimension describes the minimum floor structureheight from the raw concrete ceiling to the top edgeof the finished floor. It guarantees correct installationand use of installation devices, such as sockets, dataand multimedia connections.

08 U

FS S

chw

erla

stsy

stem

e 20

16_m

it P

rodu

kte

/ en

/ 11/

05/2

017

(LLE

xpor

t_04

557)

/ 11

/05/

2017

11

Page 12: Heavy-duty systems

System dimensions, height-adjustable square cassettes

Nominal size 4, type RKN2 4 Nominal size 4, type RKFN 2 4 

Nominal size 9, type RKN2 9 Nominal size 9, type RKFN 2 9 

08 U

FS S

chw

erla

stsy

stem

e 20

16_m

it P

rodu

kte

/ en

/ 11/

05/2

017

(LLE

xpor

t_04

557)

/ 11

/05/

2017

12

Page 13: Heavy-duty systems

08 U

FS S

chw

erla

stsy

stem

e 20

16_m

it P

rodu

kte

/ en

/ 11/

05/2

017

(LLE

xpor

t_04

557)

/ 11

/05/

2017

System dimensions, height-adjustable round cassettes

Nominal size R4, type RKR2 andRKRN2 

Nominal size R4, type RKFR2 andRKFRN2 

Nominal size R7, type RKR2 andRKRN2 

Nominal size R7, type RKFR2 andRKFRN2 

Nominal size R9, type RKR2 andRKRN2 

Nominal size R9, type RKFR2 andRKFRN2 

08 U

FS S

chw

erla

stsy

stem

e 20

16_m

it P

rodu

kte

/ en

/ 11/

05/2

017

(LLE

xpor

t_04

557)

/ 11

/05/

2017

13

Page 14: Heavy-duty systems

System dimensions, frame cassettes

Nominal size 250-3, type RK SL1  Nominal size 250-3, type RK SL2 Nominal size 250-3, type RKF SL1 

Nominal size 250-3, type RKF SL2  Nominal size 350-3, type RK SL1  Nominal size 350-3, type RK SL2 

Nominal size 350-3, type RKF SL1  Nominal size 350-3, type RKF SL2 

08 U

FS S

chw

erla

stsy

stem

e 20

16_m

it P

rodu

kte

/ en

/ 11/

05/2

017

(LLE

xpor

t_04

557)

/ 11

/05/

2017

14

Page 15: Heavy-duty systems

08 U

FS S

chw

erla

stsy

stem

e 20

16_m

it P

rodu

kte

/ en

/ 11/

05/2

017

(LLE

xpor

t_04

557)

/ 11

/05/

2017

 

 

Planning checklist

When planning heavy-duty systems, the following points should be ob-served:

Match floor structure, payloads andarea loads

Observe the minimum installation depthsof device installation units

The underfloor socket must sit entirely onthe concrete floor. Cavities under thesocket strongly reduce the loadcapacity

The underfloor socket must have anon-positive connection to the screed.Do not apply a separating strip betweenthe underfloor socket and the screed

Work floor coverings exactly up to theopening of the blanking lid,e.g. Graf9 Ø 305+1 mm

Stick down the floor coverings onto thesurface of the underfloor boxes and in thecover of the cassettes fully and firmly

 

 

 

 

 

 

 

08 U

FS S

chw

erla

stsy

stem

e 20

16_m

it P

rodu

kte

/ en

/ 11/

05/2

017

(LLE

xpor

t_04

557)

/ 11

/05/

2017

15

Page 16: Heavy-duty systems

 

 

Heavy-duty systems

Heavy-duty systems reliably supply areas with highload requirements with power, data and multimediatechnology via the floor. Car dealerships, museums,airports, stations or hotels are typical areas of appli-cation. The construction and the material thickness isspecially matched to the high load requirements. Withthe heavy-duty system, Ackermann made by OBOguarantees a particularly robust, safe and long-lastinginstallation solution.

 

08 U

FS S

chw

erla

stsy

stem

e 20

16_m

it P

rodu

kte

/ en

/ 11/

05/2

017

(LLE

xpor

t_04

557)

/ 11

/05/

2017

16

Page 17: Heavy-duty systems

08 U

FS S

chw

erla

stsy

stem

e 20

16_m

it P

rodu

kte

/ en

/ 11/

05/2

017

(LLE

xpor

t_04

557)

/ 11

/05/

2017

17

Heavy-duty systems

 

Heavy-duty frame cassette with UZD 250 18

 

Heavy-duty frame cassette with UZD 350 21

 

Height-adjustable heavy-duty cassette with UZD 250 28

 

Height-adjustable heavy-duty cassette with UZD 350 32

Page 18: Heavy-duty systems

08 U

FS S

chw

erla

stsy

stem

e 20

16_m

it P

rodu

kte

/ en

/ 11/

05/2

017

(LLE

xpor

t_04

557)

/ 11

/05/

2017

Underfloor box 250-3

18

 

UZD250-3 underfloor box

367 410 262 283 70 - 125367 410 262 283 115 - 170367 410 262 283 165 - 220

TypeUZD 250-3UZD 115170 250-3UZD 165220 250-3

Dim.Amm

Dim.Bmm

Dim.amm

Dim.bmm

Screedheightmm

Pack.pcs111

Weightkg/100 pcs.420.000480.000530.000

Item No.741003074100437410052

 

Underfloor junction and branch box for screed-covered underfloor installation systems.Side walls are prepared for duct widths 190 and 250 mm.

St Steel

FS Strip-galvanised

/pc.

 

DSSL heavy-duty support

75 - 110105 - 140135 - 170165 - 200195 - 230

TypeDSSL2 75DSSL2 105DSSL2 135DSSL2 165DSSL2 195

Screedheightmm

Pack.PU11111

Weightkg/100 PUs97.840111.040121.840132.640143.840

Item No.74105817410583741058574105877410589

155

h32

The heavy-duty supports reinforce the corner areas of the type UZD-3 underfloor box for in-creased load requirements.The VPE consists of four heavy-duty supports.

St Steel

FS Strip-galvanised

/VPE

 

Height compensation set for UZD/UGD250-3 with height 70–125 mm

115 - 170 330 80 112165 - 220 330 130 162

TypeASH250-3 B115170ASH250-3 B165220

Screedheightmm

Dim.Amm

Dim.Bmm

Dim.lmm

Pack.pcs11

Weightkg/100 pcs.76.500120.000

Item No.74101427410148

Height compensation set for underfloor boxes UZD250-3 and UGD250-3 with a constructionheight of 70 to 125 mm for construction stacking of the UZD/UGD, consisting of four fall plates,four height adjustment screws and four rotary locks.

St Steel

FS Strip-galvanised

/pc.

Height compensation set for UZD250-3 with height 115–170 mm

165 - 220 330 80 162TypeASH250-3 165220

Screedheightmm

Dim.Amm

Dim.Bmm

Dim.lmm

Pack.pcs1

Weightkg/100 pcs.82.000

Item No.7410146

Height compensation set for underfloor boxes UZD250-3 with a construction height of 115 to170 mm for construction stacking of the UZD/UGD, consisting of four fall plates, four height adjust-ment screws and four rotary locks.

St Steel

FS Strip-galvanised

/pc.

Page 19: Heavy-duty systems

08 U

FS S

chw

erla

stsy

stem

e 20

16_m

it P

rodu

kte

/ en

/ 11/

05/2

017

(LLE

xpor

t_04

557)

/ 11

/05/

2017

Underfloor box 250-3

19

Height compensation set for UZD250-3 with height 165–220 mm

215 - 270 330 80 212TypeASH250-3 215270

Screedheightmm

Dim.Amm

Dim.Bmm

Dim.lmm

Pack.pcs1

Weightkg/100 pcs.85.000

Item No.7410158

Height compensation set for underfloor boxes UZD250-3 with a construction height of 165 to220 mm for construction stacking of the UZD/UGD, consisting of four fall plates, four height adjust-ment screws and four rotary locks.

St Steel

FS Strip-galvanised

/pc.

Page 20: Heavy-duty systems

08 U

FS S

chw

erla

stsy

stem

e 20

16_m

it P

rodu

kte

/ en

/ 11/

05/2

017

(LLE

xpor

t_04

557)

/ 11

/05/

2017

Heavy-duty frame cassettes, nominal size 250-3

20

 

Heavy-duty frame cassette, blank, RKSL, nominal 250-3, load class 1

324 288 282 18 20 20324 288 282 23 25 25324 288 282 28 30 30324 288 282 38 40 40

TypeRK SL1 V2 20RK SL1 V2 25RK SL1 V2 30RK SL1 V2 40

Dim.Amm

Dim.Bmm

Dim.Cmm

Floorcoveringthicknessmm

Dim.hmm

Cassetteheightmm

Pack.pcs1111

Weightkg/100 pcs.517.000537.000555.000608.000

Item No.7405892740589674059007405908

"Blank" heavy-duty frame cassette for the creation of an inspection opening in the UZD250-3 indry or wet-cleaned floors. Load class 1 to 10 kN. Only suitable for smooth floor coverings.

V2A Stainless steel, grade 304 /pc.

 

Heavy-duty frame cassette for tube body, RKFSL, nominal 250-3, loadclass 1

324 288 282 18 20 20324 288 282 23 25 25324 288 282 28 30 30324 288 282 38 40 40

TypeRKF2 SL1 V2 20RKF2 SL1 V2 25RKF2 SL1 V2 30RKF2 SL1 V2 40

Dim.Amm

Dim.Bmm

Dim.Cmm

Floorcoveringthicknessmm

Dim.hmm

Cassetteheightmm

Pack.pcs1111

Weightkg/100 pcs.489.000508.000526.000559.000

Item No.7409482740948474094867409490

h

h+4

C

B

A

122

Heavy-duty frame cassette for tube body for the installation of accessories in the UZD250-3 in dryor wet-cleaned floors. Load class 1 to 10 kN.

V2A Stainless steel, grade 304 /pc.

 

Heavy-duty frame cassette, blank, RKSL, nominal 250-3, load class 2

324 288 282 14 20 20324 288 282 19 25 25324 288 282 24 30 30324 288 282 34 40 40

TypeRK SL2 V2 20RK SL2 V2 25RK SL2 V2 30RK SL2 V2 40

Dim.Amm

Dim.Bmm

Dim.Cmm

Floorcoveringthicknessmm

Dim.hmm

Cassetteheightmm

Pack.pcs1111

Weightkg/100 pcs.756.000775.000794.000833.000

Item No.7405932740593674059407405948

"Blank" heavy-duty frame cassette for the creation of an inspection opening in the UZD250-3 indry or wet-cleaned floors. Load class 2 to 20 kN. Only suitable for smooth floor coverings.

V2A Stainless steel, grade 304 /pc.

Heavy-duty frame cassette for tube body, RKFSL, nominal 250-3, loadclass 2

324 288 282 14 20 20324 288 282 19 25 25324 288 282 24 30 30324 288 282 34 40 40

TypeRKF2 SL2 V2 20RKF2 SL2 V2 25RKF2 SL2 V2 30RKF2 SL2 V2 40

Dim.Amm

Dim.Bmm

Dim.Cmm

Floorcoveringthicknessmm

Dim.hmm

Cassetteheightmm

Pack.pcs1111

Weightkg/100 pcs.700.000719.000738.000777.000

Item No.7409522740952474095267409530

h

h+4

C

B

A

122

Heavy-duty frame cassette for tube body for the installation of accessories in the UZD250-3 in dryor wet-cleaned floors. Load class 2 to 20 kN.

V2A Stainless steel, grade 304 /pc.

Page 21: Heavy-duty systems

08 U

FS S

chw

erla

stsy

stem

e 20

16_m

it P

rodu

kte

/ en

/ 11/

05/2

017

(LLE

xpor

t_04

557)

/ 11

/05/

2017

Underfloor box 350-3

21

 

UZD350-3 underfloor box

467 510 362 383 70 - 125467 510 362 383 115 - 170467 510 362 383 165 - 220

TypeUZD 350-3UZD 115170 350-3UZD 165220 350-3

Dim.Amm

Dim.Bmm

Dim.amm

Dim.bmm

Screedheightmm

Pack.pcs111

Weightkg/100 pcs.590.000665.000740.000

Item No.741003474100477410056

 

Underfloor junction and branch box for screed-covered underfloor installation systems.Side walls prepared for duct widths of 190, 250 and 350 mm.

St Steel

FS Strip-galvanised

/pc.

 

DSSL heavy-duty support

75 - 110105 - 140135 - 170165 - 200195 - 230

TypeDSSL2 75DSSL2 105DSSL2 135DSSL2 165DSSL2 195

Screedheightmm

Pack.PU11111

Weightkg/100 PUs97.840111.040121.840132.640143.840

Item No.74105817410583741058574105877410589

155

h32

The heavy-duty supports reinforce the corner areas of the type UZD-3 underfloor box for in-creased load requirements.The VPE consists of four heavy-duty supports.

St Steel

FS Strip-galvanised

/VPE

 

Height compensation set for UZD/UGD350-3 with height 70–125 mm

115 - 170 430 80 112165 - 220 430 130 162

TypeASH350-3 B115170ASH350-3 B165220

Screedheightmm

Dim.Amm

Dim.Bmm

Dim.lmm

Pack.pcs11

Weightkg/100 pcs.97.000151.500

Item No.74101507410156

Height compensation set for underfloor boxes UZD350-3 and UGD350-3 with a constructionheight of 70 to 125 mm for construction stacking of the UZD/UGD, consisting of four fall plates,four height adjustment screws and four rotary locks.

St Steel

FS Strip-galvanised

/pc.

Height compensation set for UZD350-3 with height 115–170 mm

165 - 220 430 80 162TypeASH350-3 165220

Screedheightmm

Dim.Amm

Dim.Bmm

Dim.lmm

Pack.pcs1

Weightkg/100 pcs.102.500

Item No.7410154

Height compensation set for underfloor boxes UZD350-3 with a construction height of 115 to170 mm for construction stacking of the UZD/UGD, consisting of four fall plates, four height adjust-ment screws and four rotary locks.

St Steel

FS Strip-galvanised

/pc.

Page 22: Heavy-duty systems

08 U

FS S

chw

erla

stsy

stem

e 20

16_m

it P

rodu

kte

/ en

/ 11/

05/2

017

(LLE

xpor

t_04

557)

/ 11

/05/

2017

Underfloor box 350-3

22

Height compensation set for UZD350-3 with height 165–220 mm

215 - 270 430 80 212TypeASH350-3 215270

Screedheightmm

Dim.Amm

Dim.Bmm

Dim.lmm

Pack.pcs1

Weightkg/100 pcs.105.000

Item No.7410164

Height compensation set for underfloor boxes UZD350-3 with a construction height of 165 to220 mm for construction stacking of the UZD/UGD, consisting of four fall plates, four height adjust-ment screws and four rotary locks.

St Steel

FS Strip-galvanised

/pc.

Page 23: Heavy-duty systems

08 U

FS S

chw

erla

stsy

stem

e 20

16_m

it P

rodu

kte

/ en

/ 11/

05/2

017

(LLE

xpor

t_04

557)

/ 11

/05/

2017

Heavy-duty frame cassettes, nominal size 350-3

23

 

Heavy-duty frame cassette, blank, RKSL, nominal 350-3, load class 1

424 388 382 18 20 20424 388 382 23 25 25424 388 382 28 30 30424 388 382 38 40 40

TypeRK SL1 V3 20RK SL1 V3 25RK SL1 V3 30RK SL1 V3 40

Dim.Amm

Dim.Bmm

Dim.Cmm

Floorcoveringthicknessmm

Dim.hmm

Cassetteheightmm

Pack.pcs1111

Weightkg/100 pcs.897.000927.000953.0001,017.000

Item No.7405912740591674059207405928

"Blank" heavy-duty frame cassette for the creation of an inspection opening in the UZD350-3 indry or wet-cleaned floors. Load class 1 to 10 kN. Only suitable for smooth floor coverings.

V2A Stainless steel, grade 304 /pc.

 

Heavy-duty frame cassette for tube body, RKFSL, nominal 350-3, loadclass 1

424 388 382 18 20 20424 388 382 23 25 25424 388 382 28 30 30424 388 382 38 40 40

TypeRKF2 SL1 V3 20RKF2 SL1 V3 25RKF2 SL1 V3 30RKF2 SL1 V3 40

Dim.Amm

Dim.Bmm

Dim.Cmm

Floorcoveringthicknessmm

Dim.hmm

Cassetteheightmm

Pack.pcs1111

Weightkg/100 pcs.912.000941.000968.0001,032.000

Item No.7409502740950474095067409510

h+4

C

h

A

B

122

Heavy-duty frame cassette for tube body for the installation of accessories in the UZD350-3 in dryor wet-cleaned floors. Load class 1 to 10 kN.

V2A Stainless steel, grade 304 /pc.

 

Heavy-duty frame cassette, blank, RKSL, nominal 350-3, load class 2

424 388 382 14 20 20424 388 382 19 25 25424 388 382 24 30 30424 388 382 34 40 40

TypeRK SL2 V3 20RK SL2 V3 25RK SL2 V3 30RK SL2 V3 40

Dim.Amm

Dim.Bmm

Dim.Cmm

Floorcoveringthicknessmm

Dim.hmm

Cassetteheightmm

Pack.pcs1111

Weightkg/100 pcs.1,346.0001,377.0001,400.0001,466.000

Item No.7405952740595674059607405968

"Blank" heavy-duty frame cassette for the creation of an inspection opening in the UZD350-3 indry or wet-cleaned floors. Load class 2 to 20 kN. Only suitable for smooth floor coverings.

V2A Stainless steel, grade 304 /pc.

Heavy-duty frame cassette for tube body, RKFSL, nominal 350-3, loadclass 2

424 388 382 14 20 20424 388 382 19 25 25424 388 382 24 30 30424 388 382 34 40 40

TypeRKF2 SL2 V3 20RKF2 SL2 V3 25RKF2 SL2 V3 30RKF2 SL2 V3 40

Dim.Amm

Dim.Bmm

Dim.Cmm

Floorcoveringthicknessmm

Dim.hmm

Cassetteheightmm

Pack.pcs1111

Weightkg/100 pcs.1,278.0001,307.0001,334.0001,398.000

Item No.7409542740954474095467409550

h+4

C

h

A

B

122

Heavy-duty frame cassette for tube body for the installation of accessories in the UZD350-3 in dryor wet-cleaned floors. Load class 2 to 20 kN.

V2A Stainless steel, grade 304 /pc.

Page 24: Heavy-duty systems

08 U

FS S

chw

erla

stsy

stem

e 20

16_m

it P

rodu

kte

/ en

/ 11/

05/2

017

(LLE

xpor

t_04

557)

/ 11

/05/

2017

Mounting set and accessories

24

 

Mounting set for UZD250-3

TypeMS3 3UT3

Pack.pcs1

Weightkg/100 pcs.49.400

Item No.7407651

Mounting set with three universal supports of type UT3 for installation in the underfloor junctionand branch box UZD250-3.Cover plates should be ordered separately.

St Steel

FS Strip-galvanised

/pc.

 

Mounting set for UZD350-3

TypeMS3 3UT4

Pack.pcs1

Weightkg/100 pcs.55.000

Item No.7407655

Mounting set with three universal supports of type UT4 for installation in the underfloor junctionand branch box UZD350-3.Cover plates should be ordered separately.

St Steel

FS Strip-galvanised

/pc.

 

Threaded sleeve for heavy-duty frame cassette

14192434

TypeGH RK SL20GH RK SL25GH RK SL30GH RK SL40

Floorcoveringthicknessmm

Pack.pcs1111

Weightkg/100 pcs.1.1341.4741.8042.404

Item No.7406859740686074068617406862

Threaded sleeves for retro-installation in heavy-duty frame cassettes.

V2A Stainless steel, grade 304 /pc.

 

Mounting key with threaded sleeve

TypeWZ 1022

Pack.pcs1

Weightkg/100 pcs.21.350

Item No.7408626

For lifting out cassettes equipped with a threaded sleeve.

/pc.

Protective conductor connection bracket

Type8AWR

Pack.pcs10

Weightkg/100 pcs.0.641

Item No.6288704

Protective conductor connection bracket to include steel and aluminium device installation trunk-ing, service poles and system components of underfloor trunking systems in the protective meas-ure.Clamping area : 2 x 1.5 − 4 mm²

St Steel

G Electrogalvanised

/pc.

Page 25: Heavy-duty systems

25

Page 26: Heavy-duty systems

08 U

FS S

chw

erla

stsy

stem

e 20

16_m

it P

rodu

kte

/ en

/ 11/

05/2

017

(LLE

xpor

t_04

557)

/ 11

/05/

2017

Underfloor box 250-3

26

 

UZD250-3 underfloor box

367 410 262 283 70 - 125367 410 262 283 115 - 170367 410 262 283 165 - 220

TypeUZD 250-3UZD 115170 250-3UZD 165220 250-3

Dim.Amm

Dim.Bmm

Dim.amm

Dim.bmm

Screedheightmm

Pack.pcs111

Weightkg/100 pcs.420.000480.000530.000

Item No.741003074100437410052

 

Underfloor junction and branch box for screed-covered underfloor installation systems.Side walls are prepared for duct widths 190 and 250 mm.

St Steel

FS Strip-galvanised

/pc.

 

DSSL heavy-duty support

75 - 110105 - 140135 - 170165 - 200195 - 230

TypeDSSL2 75DSSL2 105DSSL2 135DSSL2 165DSSL2 195

Screedheightmm

Pack.PU11111

Weightkg/100 PUs97.840111.040121.840132.640143.840

Item No.74105817410583741058574105877410589

155

h32

The heavy-duty supports reinforce the corner areas of the type UZD-3 underfloor box for in-creased load requirements.The VPE consists of four heavy-duty supports.

St Steel

FS Strip-galvanised

/VPE

 

Height compensation set for UZD/UGD250-3 with height 70–125 mm

115 - 170 330 80 112TypeASH250-3 B115170

Screedheightmm

Dim.Amm

Dim.Bmm

Dim.lmm

Pack.pcs1

Weightkg/100 pcs.76.500

Item No.7410142

165 - 220 330 130 162ASH250-3 B165220 1 120.000 7410148

Height compensation set for underfloor boxes UZD250-3 and UGD250-3 with a constructionheight of 70 to 125 mm for construction stacking of the UZD/UGD, consisting of four fall plates,four height adjustment screws and four rotary locks.

St Steel

FS Strip-galvanised

/pc.

Height compensation set for UZD250-3 with height 115–170 mm

165 - 220 330 80 162TypeASH250-3 165220

Screedheightmm

Dim.Amm

Dim.Bmm

Dim.lmm

Pack.pcs1

Weightkg/100 pcs.82.000

Item No.7410146

Height compensation set for underfloor boxes UZD250-3 with a construction height of 115 to170 mm for construction stacking of the UZD/UGD, consisting of four fall plates, four height adjust-ment screws and four rotary locks.

St Steel

FS Strip-galvanised

/pc.

Page 27: Heavy-duty systems

08 U

FS S

chw

erla

stsy

stem

e 20

16_m

it P

rodu

kte

/ en

/ 11/

05/2

017

(LLE

xpor

t_04

557)

/ 11

/05/

2017

Underfloor box 250-3

27

Height compensation set for UZD250-3 with height 165–220 mm

215 - 270 330 80 212TypeASH250-3 215270

Screedheightmm

Dim.Amm

Dim.Bmm

Dim.lmm

Pack.pcs1

Weightkg/100 pcs.85.000

Item No.7410158

Height compensation set for underfloor boxes UZD250-3 with a construction height of 165 to220 mm for construction stacking of the UZD/UGD, consisting of four fall plates, four height adjust-ment screws and four rotary locks.

St Steel

FS Strip-galvanised

/pc.

Page 28: Heavy-duty systems

08 U

FS S

chw

erla

stsy

stem

e 20

16_m

it P

rodu

kte

/ en

/ 11/

05/2

017

(LLE

xpor

t_04

557)

/ 11

/05/

2017

Heavy-duty cassette, square design, height-adjustable

28

 

Heavy-duty mounting lid for square cassettes 4, nominal size 250-3

282 201TypeDUG 250-3 4SL

Dim.Amm

Dim.amm

Pack.pcs1

Weightkg/100 pcs.146.500

Item No.7401404

The heavy-duty mounting lid for the type UZD250-3 underfloor box is suitable for installation in asquare heavy-duty cassette of nominal size 4. The installation opening is recessed by 3 mm andcan be closed subsequently by a lid blanking plate.

St Steel

FS Strip-galvanised

/pc.

 

Height adjustment unit for heavy-duty mounting lid

75 - 110105 - 140135 - 170165 - 200195 - 230

TypeDUG SL75DUG SL105DUG SL135DUG SL165DUG SL195

Screedheightmm

Pack.PU11111

Weightkg/100 PUs121.600153.700172.500193.300210.500

Item No.74096807409682740968474096867409688

The height adjustment units rated for increased load requirements permit the screed-flush heightadjustment of the heavy-duty mounting lid and are to be ordered separately.The VPE consists of four height adjustment units.

St Steel

G Electrogalvanised

/VPE

 

Height-adjustable heavy-duty cassette, blank, RKNSL, nominal size 4,stainless steel

100 15 100 - 150 V2A105 20 105 - 155 V2A

TypeRKN2 4 VMSL1N 15RKN2 4 VMSL1N 20

Dim.hmm

Floorcoveringthicknessmm

Floorheightmm

Material symbol

Pack.pcs11

Weightkg/100 pcs.389.000400.000

Item No.7409008740901019

9h

Heavy-duty "blank" square cassette of nominal size 4 for the creation of an inspection opening intrunking systems, raised or cavity floors, in dry or wet-cleaned floors. Load class 1 to 10 kN. Onlysuitable for smooth floor coverings.

V2A Stainless steel, grade 304 /pc.

Height-adjustable heavy-duty cassette for tube body RKFNSL, nominalsize 4, stainless steel

100 15 100 - 150 V2A105 20 105 - 155 V2A

TypeRKFN2 4 VMSL1N15RKFN2 4 VMSL1N20

Dim.hmm

Floorcoveringthicknessmm

Floorheightmm

Material symbol

Pack.pcs11

Weightkg/100 pcs.355.500367.000

Item No.74093827409384

h19

9

122 Heavy-duty square cassette for tube body of nominal size 4 for the installation of accessories intrunking systems, raised or cavity floors, in dry or wet-cleaned floors. Load class 1 to 10 kN.

V2A Stainless steel, grade 304 /pc.

Page 29: Heavy-duty systems

08 U

FS S

chw

erla

stsy

stem

e 20

16_m

it P

rodu

kte

/ en

/ 11/

05/2

017

(LLE

xpor

t_04

557)

/ 11

/05/

2017

Heavy-duty cassettes, round design, height-adjustable

29

 

Heavy-duty mounting lid for round cassette R4, nominal size 250-3

282 215TypeDUG 250-3 R4SL

Dim.Amm

Dim.d Ømm

Pack.pcs1

Weightkg/100 pcs.159.300

Item No.7401406

The heavy-duty mounting lid for the UZD250-3 underfloor box is suitable for the installation of around heavy-duty cassette of nominal size R4. The installation opening is recessed by 3 mm andcan be closed subsequently by a lid blanking plate.

St Steel

FS Strip-galvanised

/pc.

 

Height adjustment unit for heavy-duty mounting lid

75 - 110105 - 140135 - 170165 - 200195 - 230

TypeDUG SL75DUG SL105DUG SL135DUG SL165DUG SL195

Screedheightmm

Pack.PU11111

Weightkg/100 PUs121.600153.700172.500193.300210.500

Item No.74096807409682740968474096867409688

The height adjustment units rated for increased load requirements permit the screed-flush heightadjustment of the heavy-duty mounting lid and are to be ordered separately.The VPE consists of four height adjustment units.

St Steel

G Electrogalvanised

/VPE

 

Height-adjustable heavy-duty cassette, blank, RKRSL, nominal sizeR4, stainless steel

105 20 105 - 155 V2A109 25 109 - 159 V2A

TypeRKR2 4SL2 V2 20RKR2 4SL2 V2 25

Dim.hmm

Floorcoveringthicknessmm

Floorheightmm

Material symbol

Pack.pcs11

Weightkg/100 pcs.559.000624.000

Item No.74090727409074

h21

4

Round, "blank", heavy-duty cassette of nominal size R4 for the creation of an inspection openingin trunking systems, raised and cavity floors, in dry or wet-care floors. Load class 2 to 20 kN. Onlysuitable for smooth floor coverings.

V2A Stainless steel, grade 304 /pc.

Height-adjustable heavy-duty cassette for tube body RKFRSL, nominalsize R4, stainless steel

110 20 105 - 155 V2A114 25 109 - 159 V2A

TypeRKFR2 4 SL2V2 20RKFR2 4 SL2V2 25

Dim.hmm

Floorcoveringthicknessmm

Floorheightmm

Material symbol

Pack.pcs11

Weightkg/100 pcs.604.000669.000

Item No.74094627409464

h21

4

122Round heavy-duty cassette for tube body of nominal size R4 for the installation of accessories intrunking systems, raised and cavity floors, in dry or wet-cleaned floors. Load class 2 to 20 kN.

V2A Stainless steel, grade 304 /pc.

Page 30: Heavy-duty systems

08 U

FS S

chw

erla

stsy

stem

e 20

16_m

it P

rodu

kte

/ en

/ 11/

05/2

017

(LLE

xpor

t_04

557)

/ 11

/05/

2017

Underfloor box 350-3

30

 

UZD350-3 underfloor box

467 510 362 383 70 - 125467 510 362 383 115 - 170467 510 362 383 165 - 220

TypeUZD 350-3UZD 115170 350-3UZD 165220 350-3

Dim.Amm

Dim.Bmm

Dim.amm

Dim.bmm

Screedheightmm

Pack.pcs111

Weightkg/100 pcs.590.000665.000740.000

Item No.741003474100477410056

 

Underfloor junction and branch box for screed-covered underfloor installation systems.Side walls prepared for duct widths of 190, 250 and 350 mm.

St Steel

FS Strip-galvanised

/pc.

 

DSSL heavy-duty support

75 - 110105 - 140135 - 170165 - 200195 - 230

TypeDSSL2 75DSSL2 105DSSL2 135DSSL2 165DSSL2 195

Screedheightmm

Pack.PU11111

Weightkg/100 PUs97.840111.040121.840132.640143.840

Item No.74105817410583741058574105877410589

155

h32

The heavy-duty supports reinforce the corner areas of the type UZD-3 underfloor box for in-creased load requirements.The VPE consists of four heavy-duty supports.

St Steel

FS Strip-galvanised

/VPE

 

Height compensation set for UZD/UGD350-3 with height 70–125 mm

115 - 170 430 80 112TypeASH350-3 B115170

Screedheightmm

Dim.Amm

Dim.Bmm

Dim.lmm

Pack.pcs1

Weightkg/100 pcs.97.000

Item No.7410150

165 - 220 430 130 162ASH350-3 B165220 1 151.500 7410156

Height compensation set for underfloor boxes UZD350-3 and UGD350-3 with a constructionheight of 70 to 125 mm for construction stacking of the UZD/UGD, consisting of four fall plates,four height adjustment screws and four rotary locks.

St Steel

FS Strip-galvanised

/pc.

Height compensation set for UZD350-3 with height 115–170 mm

165 - 220 430 80 162TypeASH350-3 165220

Screedheightmm

Dim.Amm

Dim.Bmm

Dim.lmm

Pack.pcs1

Weightkg/100 pcs.102.500

Item No.7410154

Height compensation set for underfloor boxes UZD350-3 with a construction height of 115 to170 mm for construction stacking of the UZD/UGD, consisting of four fall plates, four height adjust-ment screws and four rotary locks.

St Steel

FS Strip-galvanised

/pc.

Page 31: Heavy-duty systems

08 U

FS S

chw

erla

stsy

stem

e 20

16_m

it P

rodu

kte

/ en

/ 11/

05/2

017

(LLE

xpor

t_04

557)

/ 11

/05/

2017

Underfloor box 350-3

31

Height compensation set for UZD350-3 with height 165–220 mm

215 - 270 430 80 212TypeASH350-3 215270

Screedheightmm

Dim.Amm

Dim.Bmm

Dim.lmm

Pack.pcs1

Weightkg/100 pcs.105.000

Item No.7410164

Height compensation set for underfloor boxes UZD350-3 with a construction height of 165 to220 mm for construction stacking of the UZD/UGD, consisting of four fall plates, four height adjust-ment screws and four rotary locks.

St Steel

FS Strip-galvanised

/pc.

Page 32: Heavy-duty systems

08 U

FS S

chw

erla

stsy

stem

e 20

16_m

it P

rodu

kte

/ en

/ 11/

05/2

017

(LLE

xpor

t_04

557)

/ 11

/05/

2017

Heavy-duty cassette, square design, height-adjustable

32

 

Heavy-duty mounting lid for square cassettes 4, nominal size 350-3

383 201TypeDUG 350-3 4SL

Dim.Amm

Dim.amm

Pack.pcs1

Weightkg/100 pcs.355.600

Item No.7401408

The heavy-duty mounting lid for the type UZD350-3 underfloor box is suitable for installation in asquare heavy-duty cassette of nominal size 4. The installation opening is recessed by 3 mm andcan be closed subsequently by a lid blanking plate.

St Steel

FS Strip-galvanised

/pc.

 

Height adjustment unit for heavy-duty mounting lid

75 - 110105 - 140135 - 170165 - 200195 - 230

TypeDUG SL75DUG SL105DUG SL135DUG SL165DUG SL195

Screedheightmm

Pack.PU11111

Weightkg/100 PUs121.600153.700172.500193.300210.500

Item No.74096807409682740968474096867409688

The height adjustment units rated for increased load requirements permit the screed-flush heightadjustment of the heavy-duty mounting lid and are to be ordered separately.The VPE consists of four height adjustment units.

St Steel

G Electrogalvanised

/VPE

 

Height-adjustable heavy-duty cassette, blank, RKNSL, nominal size 4,stainless steel

100 15 100 - 150 V2A105 20 105 - 155 V2A

TypeRKN2 4 VMSL1N 15RKN2 4 VMSL1N 20

Dim.hmm

Floorcoveringthicknessmm

Floorheightmm

Material symbol

Pack.pcs11

Weightkg/100 pcs.389.000400.000

Item No.7409008740901019

9h

Heavy-duty "blank" square cassette of nominal size 4 for the creation of an inspection opening intrunking systems, raised or cavity floors, in dry or wet-cleaned floors. Load class 1 to 10 kN. Onlysuitable for smooth floor coverings.

V2A Stainless steel, grade 304 /pc.

Height-adjustable heavy-duty cassette for tube body RKFNSL, nominalsize 4, stainless steel

100 15 100 - 150 V2A105 20 105 - 155 V2A

TypeRKFN2 4 VMSL1N15RKFN2 4 VMSL1N20

Dim.hmm

Floorcoveringthicknessmm

Floorheightmm

Material symbol

Pack.pcs11

Weightkg/100 pcs.355.500367.000

Item No.74093827409384

h19

9

122 Heavy-duty square cassette for tube body of nominal size 4 for the installation of accessories intrunking systems, raised or cavity floors, in dry or wet-cleaned floors. Load class 1 to 10 kN.

V2A Stainless steel, grade 304 /pc.

Page 33: Heavy-duty systems

08 U

FS S

chw

erla

stsy

stem

e 20

16_m

it P

rodu

kte

/ en

/ 11/

05/2

017

(LLE

xpor

t_04

557)

/ 11

/05/

2017

Heavy-duty cassette, square design, height-adjustable

33

 

Heavy-duty mounting lid for square cassettes 9, nominal size 350-3

383 244TypeDUG 350-3 9SL

Dim.Amm

Dim.amm

Pack.pcs1

Weightkg/100 pcs.294.400

Item No.7401410

The heavy-duty mounting lid for the type UZD350-3 underfloor box is suitable for installation in asquare heavy-duty cassette of nominal size 9. The installation opening is recessed by 3 mm andcan be closed subsequently by a lid blanking plate.

St Steel

FS Strip-galvanised

/pc.

 

Height adjustment unit for heavy-duty mounting lid

75 - 110105 - 140135 - 170165 - 200195 - 230

TypeDUG SL75DUG SL105DUG SL135DUG SL165DUG SL195

Screedheightmm

Pack.PU11111

Weightkg/100 PUs121.600153.700172.500193.300210.500

Item No.74096807409682740968474096867409688

The height adjustment units rated for increased load requirements permit the screed-flush heightadjustment of the heavy-duty mounting lid and are to be ordered separately.The VPE consists of four height adjustment units.

St Steel

G Electrogalvanised

/VPE

 

Height-adjustable heavy-duty cassette, blank, RKNSL, nominal size 9,stainless steel

100 16 100 - 150 V2A105 21 105 - 155 V2A

TypeRKN2 9 VMSL1N 16RKN2 9 VMSL1N 21

Dim.hmm

Floorcoveringthicknessmm

Floorheightmm

Material symbol

Pack.pcs11

Weightkg/100 pcs.550.000563.000

Item No.74090287409030

h24

3

Heavy-duty "blank" square cassette of nominal size 9 for the creation of an inspection opening intrunking systems, raised or cavity floors, in dry or wet-cleaned floors. Load class 1 to 10 kN. Onlysuitable for smooth floor coverings.

V2A Stainless steel, grade 304 /pc.

Height-adjustable heavy-duty cassette for tube body RKFNSL, nominalsize 9, stainless steel

100 16 100 - 150 V2A105 21 105 - 155 V2A

TypeRKFN2 9 VMSL1N16RKFN2 9 VMSL1N21

Dim.hmm

Floorcoveringthicknessmm

Floorheightmm

Material symbol

Pack.pcs11

Weightkg/100 pcs.501.000514.000

Item No.74093887409390

h24

3

122Heavy-duty square cassette for tube body of nominal size 9 for the installation of accessories intrunking systems, raised or cavity floors, in dry or wet-cleaned floors. Load class 1 to 10 kN.

V2A Stainless steel, grade 304 /pc.

Page 34: Heavy-duty systems

08 U

FS S

chw

erla

stsy

stem

e 20

16_m

it P

rodu

kte

/ en

/ 11/

05/2

017

(LLE

xpor

t_04

557)

/ 11

/05/

2017

Heavy-duty cassettes, round design, height-adjustable

34

 

Heavy-duty mounting lid for round cassette R4, nominal size 350-3

383 215TypeDUG 350-3 R4SL

Dim.Amm

Dim.d Ømm

Pack.pcs1

Weightkg/100 pcs.370.400

Item No.7401412

The heavy-duty mounting lid for the UZD350-3 underfloor box is suitable for the installation of around heavy-duty cassette of nominal size R4. The installation opening is recessed by 3 mm andcan be closed subsequently by a lid blanking plate.

St Steel

FS Strip-galvanised

/pc.

 

Height adjustment unit for heavy-duty mounting lid

75 - 110105 - 140135 - 170165 - 200195 - 230

TypeDUG SL75DUG SL105DUG SL135DUG SL165DUG SL195

Screedheightmm

Pack.PU11111

Weightkg/100 PUs121.600153.700172.500193.300210.500

Item No.74096807409682740968474096867409688

The height adjustment units rated for increased load requirements permit the screed-flush heightadjustment of the heavy-duty mounting lid and are to be ordered separately.The VPE consists of four height adjustment units.

St Steel

G Electrogalvanised

/VPE

 

Height-adjustable heavy-duty cassette, blank, RKRSL, nominal sizeR4, stainless steel

105 20 105 - 155 V2A109 25 109 - 159 V2A

TypeRKR2 4SL2 V2 20RKR2 4SL2 V2 25

Dim.hmm

Floorcoveringthicknessmm

Floorheightmm

Material symbol

Pack.pcs11

Weightkg/100 pcs.559.000624.000

Item No.74090727409074

h21

4

Round, "blank", heavy-duty cassette of nominal size R4 for the creation of an inspection openingin trunking systems, raised and cavity floors, in dry or wet-care floors. Load class 2 to 20 kN. Onlysuitable for smooth floor coverings.

V2A Stainless steel, grade 304 /pc.

Height-adjustable heavy-duty cassette for tube body RKFRSL, nominalsize R4, stainless steel

110 20 105 - 155 V2A114 25 109 - 159 V2A

TypeRKFR2 4 SL2V2 20RKFR2 4 SL2V2 25

Dim.hmm

Floorcoveringthicknessmm

Floorheightmm

Material symbol

Pack.pcs11

Weightkg/100 pcs.604.000669.000

Item No.74094627409464

h21

4

122Round heavy-duty cassette for tube body of nominal size R4 for the installation of accessories intrunking systems, raised and cavity floors, in dry or wet-cleaned floors. Load class 2 to 20 kN.

V2A Stainless steel, grade 304 /pc.

Page 35: Heavy-duty systems

08 U

FS S

chw

erla

stsy

stem

e 20

16_m

it P

rodu

kte

/ en

/ 11/

05/2

017

(LLE

xpor

t_04

557)

/ 11

/05/

2017

Heavy-duty cassettes, round design, height-adjustable

35

 

Heavy-duty mounting lid for round cassette R7, nominal size 350-3

383 275TypeDUG 350-3 R7SL

Dim.Amm

Dim.d Ømm

Pack.pcs1

Weightkg/100 pcs.370.400

Item No.7401414

The heavy-duty mounting lid for the UZD350-3 underfloor box is suitable for the installation of around heavy-duty cassette of nominal size R7. The installation opening is recessed by 3 mm andcan be closed subsequently by a lid blanking plate.

St Steel

FS Strip-galvanised

/pc.

 

Height adjustment unit for heavy-duty mounting lid

75 - 110105 - 140135 - 170165 - 200195 - 230

TypeDUG SL75DUG SL105DUG SL135DUG SL165DUG SL195

Screedheightmm

Pack.PU11111

Weightkg/100 PUs121.600153.700172.500193.300210.500

Item No.74096807409682740968474096867409688

The height adjustment units rated for increased load requirements permit the screed-flush heightadjustment of the heavy-duty mounting lid and are to be ordered separately.The VPE consists of four height adjustment units.

St Steel

G Electrogalvanised

/VPE

 

Height-adjustable heavy-duty cassette, blank, RKRSL, nominal sizeR7, stainless steel

105 20 105 - 155 V2A109 25 109 - 159 V2A

TypeRKR2 7SL2 V2 20RKR2 7SL2 V2 25

Dim.hmm

Floorcoveringthicknessmm

Floorheightmm

Material symbol

Pack.pcs11

Weightkg/100 pcs.894.000966.000

Item No.74090927409094

h27

4

Round, "blank", heavy-duty cassette of nominal size R7 for the creation of an inspection openingin trunking systems, raised and cavity floors, in dry or wet-cleaned floors. Load class 2 to 20 kN.Only suitable for smooth floor coverings.

V2A Stainless steel, grade 304 /pc.

Height-adjustable heavy-duty cassette for tube body RKFRSL, nominalsize R7, stainless steel

110 20 105 - 155 V2A114 25 109 - 159 V2A

TypeRKFR2 7 SL2V2 20RKFR2 7 SL2V2 25

Dim.hmm

Floorcoveringthicknessmm

Floorheightmm

Material symbol

Pack.pcs11

Weightkg/100 pcs.885.000947.000

Item No.74094667409468 27

4

122

h

Round heavy-duty cassette for tube body of nominal size R7 for the installation of accessories intrunking systems, raised and cavity floors, in dry or wet-cleaned floors. Load class 2 to 20 kN.

V2A Stainless steel, grade 304 /pc.

Page 36: Heavy-duty systems

08 U

FS S

chw

erla

stsy

stem

e 20

16_m

it P

rodu

kte

/ en

/ 11/

05/2

017

(LLE

xpor

t_04

557)

/ 11

/05/

2017

Heavy-duty cassettes, round design, height-adjustable

36

 

Heavy-duty mounting lid for round cassette R9, nominal size 350-3

383 305TypeDUG 350-3 R9SL

Dim.Amm

Dim.d Ømm

Pack.pcs1

Weightkg/100 pcs.252.500

Item No.7401416

The heavy-duty mounting lid for the UZD350-3 underfloor box is suitable for the installation of around heavy-duty cassette of nominal size R9. The installation opening is recessed by 3 mm andcan be closed subsequently by a lid blanking plate.

St Steel

FS Strip-galvanised

/pc.

 

Height adjustment unit for heavy-duty mounting lid

75 - 110105 - 140135 - 170165 - 200195 - 230

TypeDUG SL75DUG SL105DUG SL135DUG SL165DUG SL195

Screedheightmm

Pack.PU11111

Weightkg/100 PUs121.600153.700172.500193.300210.500

Item No.74096807409682740968474096867409688

The height adjustment units rated for increased load requirements permit the screed-flush heightadjustment of the heavy-duty mounting lid and are to be ordered separately.The VPE consists of four height adjustment units.

St Steel

G Electrogalvanised

/VPE

 

Height-adjustable heavy-duty cassette for tube body RKFRSL, nominalsize R9, stainless steel

110 20 105 - 155 V2A114 25 109 - 159 V2A

TypeRKFR2 9 SL2V2 20RKFR2 9 SL2V2 25

Dim.hmm

Floorcoveringthicknessmm

Floorheightmm

Material symbol

Pack.pcs11

Weightkg/100 pcs.589.000647.000

Item No.7409470740947230

4

122

h

Round heavy-duty cassette for tube body of nominal size R9 for the installation of accessories intrunking systems, raised and cavity floors, in dry or wet-cleaned floors. Load class 2 to 20 kN.

V2A Stainless steel, grade 304 /pc.

Height-adjustable heavy-duty cassette, blank, RKRSL, nominal sizeR9, stainless steel

105 20 105 - 155 V2A109 25 109 - 159 V2A

TypeRKR2 9SL2 V2 20RKR2 9SL2 V2 25

Dim.hmm

Floorcoveringthicknessmm

Floorheightmm

Material symbol

Pack.pcs11

Weightkg/100 pcs.664.0001,054.000

Item No.74091127409114

h30

4

Round, "blank", heavy-duty cassette of nominal size R9 for the creation of an inspection openingin trunking systems, raised and cavity floors, in dry or wet-cleaned floors. Load class 2 to 20 kN.Only suitable for smooth floor coverings.

V2A Stainless steel, grade 304 /pc.

Page 37: Heavy-duty systems

08 U

FS S

chw

erla

stsy

stem

e 20

16_m

it P

rodu

kte

/ en

/ 11/

05/2

017

(LLE

xpor

t_04

557)

/ 11

/05/

2017

Expansion and spare parts for heavy-duty cassettes

37

 

Tube body with cover plate, without handle clamp, for frame cassetteand height-adjustable cassette

TypeTUK2 V

Pack.pcs1

Weightkg/100 pcs.59.000

Item No.7428141

110

35

Height-adjustable cord outlet for installation in RKF frame cassettes and in height-adjustable roundand square RKFR and RKFN cassettes. Raised height when used, flushfloor when unused. Usein wet-care floors. Tube body cover made of V2A.

Zn Die-cast zinc

N Nickel-plated

/pc.

 

Tube body with cover plate, with handle clamp, for frame cassette andheight-adjustable cassette

TypeTUK2 GV

Pack.pcs1

Weightkg/100 pcs.59.000

Item No.7428140

110

35

Height-adjustable cord outlet for installation in RKF frame cassettes and in height-adjustable roundand square RKFR and RKFN cassettes. Raised height when used, flushfloor when unused. Usein wet-care floors. Tube body cover and handle made of V2A.

Zn Die-cast zinc

N Nickel-plated

/pc.

 

Tube body with floor covering recess, with handle clamp, for framecassette and height-adjustable cassette

TypeTUK2 G4

Pack.pcs1

Weightkg/100 pcs.45.000

Item No.7428142

35

110

Height-adjustable cord outlet for installation in RKF frame cassettes and in height-adjustable roundand square RKFR and RKFN cassettes. Raised height when used, flushfloor when unused. Usein wet-care floors. With 4 mm floor covering recess for construction-side panelling with cut resist-ant floor covering, with handle clamp.

Zn Die-cast zinc

N Nickel-plated

/pc.

 

Round seal for tube body

TypeRD2 TUK2

Pack.pcs1

Weightkg/100 pcs.0.200

Item No.7407098

100

Round seal for tube body TUK2 - spare part.

EPDM Ethylene propylene diene rubber DIN 1629 /pc.

Care agent for cassette seal and tube body seal

TypePF-G

Pack.pcs1

Weightkg/100 pcs.0.800

Item No.7407110

Cleaning agent for round seals RD2, flat seals FD2 QNK and tube body seal RD2TUK2.

PTFE Synthetic oil-based montage paste /pc.

Page 38: Heavy-duty systems

08 U

FS S

chw

erla

stsy

stem

e 20

16_m

it P

rodu

kte

/ en

/ 11/

05/2

017

(LLE

xpor

t_04

557)

/ 11

/05/

2017

Expansion and spare parts for heavy-duty cassettes

38

 

Height adjustment unit RKNEV2

110150190230270

TypeRK NEV2 110RK NEV2 150RK NEV2 190RK NEV2 230RK NEV2 270

Dim.hmm

Pack.PU11111

Weightkg/100 PUs25.20030.00035.00040.00045.800

Item No.74058157405816740581774058187405819

h

M8

60x30

110 140 - 190 145 - 195 145 - 190 150 - 195 145 - 195 150 - 195 133 - 173150 180 - 230 185 - 235 185 - 230 190 - 235 185 - 235 190 - 235 173 - 213190 220 - 270 225 - 275 225 - 270 230 - 275 225 - 275 230 - 275 213 - 253230 260 - 310 265 - 315 265 - 310 270 - 315 265 - 315 270 - 315 253 - 293270 300 - 350 305 - 355 305 - 350 310 - 355 305 - 355 310 - 355 293 - 333

mm mm mm mm mm mm mm mm

Dimen-sion "h"

RKN2,20 mm

RKN2,25 mm

RK(S+F)N2,20 mm

RK(S+F)N2,25 mm

RKR2,20/25 mm

RK(S+F)R2,20/25 mm

OKB  Dimensions   

For flush-floor height adjustment of the height adjustable cassette units and the OKB screed-flushtrunking system. The VPE consists of 4 height adjustment units.

St Steel

G Electrogalvanised

/VPE

 

Flat seal for square height-adjustable cassette, nom-inal size NG4 and NG9

EPDM Ethylene propylene diene rubber DIN 1629 /pc.

TypeFD 4 QNK2FD 9 QNK2

Pack.pcs11

Weightkg/100 pcs.1.3001.700

Item No.74071077407109

 

190

Flat seal for height-adjustable square cassettes RKN2 and RKFN2 ofnominal sizes 4 and 9.

 

Round seal for height-ad-justable round cassetteR4, R7 and R9

EPDM Ethylene propylene diene rubber DIN 1629 /pc.

——

TypeRD R4 NK2RD R7 NK2RD R9 NK2

Pack.pcs111

Weightkg/100 pcs.1.3001.7001.500

Item No.740707374070747407075

 

D

Round seal for height-adjustable round cassettes RKR2 and RKFR2 ofnominal sizes R4, R7 and R9.

Mounting key withthreaded sleeve

/pc.

TypeWZ 1022

Pack.pcs1

Weightkg/100 pcs.21.350

Item No.7408626

 

For lifting out cassettes equipped with a threaded sleeve.

Threaded sleeve forheight-adjustable, roundheavy-duty cassette

V2A Stainless steel, grade 304 /pc.

2025

TypeGH NR SL20GH NR SL25

Floorcoveringthicknessmm

Pack.pcs11

Weightkg/100 pcs.1.3501.610

Item No.74068707406871

Threaded sleeves for retro-installation in round heavy-duty cassettes.

Page 39: Heavy-duty systems

39

Page 40: Heavy-duty systems

OBO Bettermann GmbH & Co. KGPO Box 112058694 MendenGERMANY

Customer Service GermanyTel.: +49 (0)2373 89 - 1700Fax: +49 (0)2373 89 - 1238E-mail: [email protected]

www.obo-bettermann.com

Building Connections

© O

BO

Bet

term

ann

05/2

017 E

N