2
HFL100EX Explosion proof LED helideck floodlight Orga BV Strickledeweg 13 3125 AT SCHIEDAM The Netherlands P.O. Box 3046 3101 EA SCHIEDAM The Netherlands T +31 (0)10 208 5555 F +31 (0)10 437 8445 [email protected] www.orga.nl All values mentioned in this document are typical values Document can be subject to modifications, without prior notice. Datasheet no.: HFL100EX rev 8 Explosion proof LED helideck floodlight to provide illumination of the landing area of the helideck. Key features Reliable LED floodlight gives low cost of ownership and maintenance Low power consumption due to highly efficient LED light source and lens system Certified for Zone 1 areas with gas explosion hazard Low profile design (<250 mm) allows direct mounting on helideck Offshore resistant, high quality coating on cast light alloy base Stainless steel mounting facilities to prevent corrosion problems, and integrated junction box Wide beam spread for optimum equal helideck illumination Easy aiming facility to meet requirement of computer simulation for helideck illumination Standards/Certification Complies with ICAO Annex 14, Volume ll; International standards and recommended practices: Aerodromes, July 2013, chapter 5, paragraph 5.3.9 – Helideck Floodlights Complies with Normam 27; Chapter 5; Section 0505d Complies with Norsok C-004; Section 18.3 SIRA 17ATEX0005 X; ATEX II 2 G Ex db eb op is IIB T4 EN 60079-0, EN 60079-1, EN 60079-7, EN 60079-28 IECEx KIWA 17.0003X; Ex db eb op is IIB T4 Gb IEC 60079-0, IEC 60079-1, IEC 60079-7, IEC 60079-28 Inmetro NCC 18.0033X; Ex db eb op is IIB T4 Gb IP64 ABNT NBR IEC 60079-0, ABNT NBR IEC 60079-1, ABNT NBR IEC 60079-7 and ABNT NBR IEC 60079-28 Performance characteristics Highly efficient LED light source and lens system No glare Aiming facilities provided Electrical characteristics Operating voltage: see table Power consumption: See table Connection details: max. 4 mm²; 2 x M25x1,5 cable gland entries Earth connection: internal max. 4 mm² and external M5 Physical characteristics Dimensions (L x W x H): 250 x 480 x 215 mm Weight: max 20Kg Design degree of protection: IP66 Operating temperature range: -50°C to +55°C System design, control and monitoring When used in a floodlight system the average horizontal illuminance of the floodlighting will meet the regulatory requirements of at least 10 lux, with a uniformity ratio (average to minimum) of not more than 8:1 measured on the surface of the TLOF.

HFL100EX - orga.nl · • ABNT NBR IEC 60079-0, ABNT NBR IEC 60079-1, ABNT NBR IEC 60079-7 and ABNT NBR IEC 60079-28 Performance characteristics • Highly efficient LED light source

  • Upload
    vuduong

  • View
    365

  • Download
    4

Embed Size (px)

Citation preview

HFL100EXExplosion proof LED helideck floodlight

Orga BVStrickledeweg 133125 AT SCHIEDAMThe Netherlands

P.O. Box 30463101 EA SCHIEDAMThe Netherlands

T +31 (0)10 208 5555F +31 (0)10 437 [email protected]

All values mentioned in this document are typical values

Document can be subject to modifications, without prior notice. Datasheet no.: HFL100EX rev 8

Explosion proof LED helideck floodlight to provide illumination of the landing area of thehelideck.

Key features• Reliable LED floodlight gives

low cost of ownership andmaintenance

• Low power consumption due tohighly efficient LED lightsource and lens system

• Certified for Zone 1 areas withgas explosion hazard

• Low profile design (<250 mm)allows direct mounting onhelideck

• Offshore resistant, high qualitycoating on cast light alloy base

• Stainless steel mountingfacilities to prevent corrosionproblems, and integratedjunction box

• Wide beam spread for optimumequal helideck illumination

• Easy aiming facility to meetrequirement of computersimulation for helideckillumination

Standards/Certification• Complies with ICAO Annex 14,

Volume ll; Internationalstandards and recommendedpractices: Aerodromes, July2013, chapter 5, paragraph 5.3.9– Helideck Floodlights

• Complies with Normam 27; Chapter5; Section 0505d

• Complies with Norsok C-004;Section 18.3

• SIRA 17ATEX0005 X; ATEX II 2 GEx db eb op is IIB T4

• EN 60079-0, EN 60079-1, EN60079-7, EN 60079-28

• IECEx KIWA 17.0003X; Ex db eb opis IIB T4 Gb

• IEC 60079-0, IEC 60079-1, IEC60079-7, IEC 60079-28

• Inmetro NCC 18.0033X; Ex db ebop is IIB T4 Gb IP64

• ABNT NBR IEC 60079-0, ABNT NBRIEC 60079-1, ABNT NBR IEC60079-7 and ABNT NBR IEC60079-28

Performance characteristics• Highly efficient LED light

source and lens system• No glare• Aiming facilities provided

Electrical characteristics• Operating voltage: see table• Power consumption: See table• Connection details: max. 4 mm²;

2 x M25x1,5 cable gland entries• Earth connection: internal max.

4 mm² and external M5

Physical characteristics• Dimensions (L x W x H):

250 x 480 x 215 mm• Weight: max 20Kg • Design degree of protection:

IP66• Operating temperature range:

-50°C to +55°C

System design, control andmonitoring• When used in a floodlight system

the average horizontalilluminance of the floodlightingwill meet the regulatoryrequirements of at least 10 lux,with a uniformity ratio (averageto minimum) of not more than 8:1measured on the surface of theTLOF.

HFL100EXExplosion proof LED helideck floodlight

Orga BVStrickledeweg 133125 AT SCHIEDAMThe Netherlands

P.O. Box 30463101 EA SCHIEDAMThe Netherlands

T +31 (0)10 208 5555F +31 (0)10 437 [email protected]

All values mentioned in this document are typical values

Document can be subject to modifications, without prior notice. Datasheet no.: HFL100EX rev 8 page 2 of 2