1
Project Address: Project Data Cover Sheet-REV 04 Sheet Title 15003 Project No: Issue Hicks Family Nissan Project Name: Date: 3202 IH-69 North Frontage Rd., Robstown, TX, 78380, County D C B A 1 2 3 4 5 Copyrightゥ 2015 CB1- G100 C:\EDR Projects\15003 Hicks Robstown Property\ArchiCAD\Non Issued-004 ADD-Hicks-IFC.pln 1 6 1 2 3 4 5 6 E phone: 361.537.4400 [email protected] October 14, 2015 IFC-October 14, 2015 01 REV-October 27, 2015 02 REV-November 3, 2015 03 REV-November 16, 2015 04 REV-February 10, 2016 Revision 1 2 3 4 CB1 149A CB1 149E CB1 100B CB1 148A CB1 151 CB1-144E Rated CB1-129A Rated CB1 152B CB1 103A CB1 103D CB1 103E CB1 100A CB1 148D CB1 148E CB1 148C CB1 144A CB1 152A CB1 150D CB1-134B Rated CB1 129B CB1 133 CB1 130B CB1 148B CB1-138 Rated CB1 149F CB1 149B CB1 149J CB1 149H CB1 149I CB1 150A CB1 150B CB1 150C CB1-136 Rated CB1 153A CB1 152C F.E. F.E. F.E. F.E. F.E. Fire Shutter, 2 hour F.E. F.E. F.E. F.E. F.E. 2 Hour UL#U419 fire barrier (Reduced 1 hour due to sprinkler system) 1 Hour UL#U419 fire barrier 2 Hour UL#U419 fire barrier (Reduced 1 hour due to sprinkler system) Fire rated door Fire rated doors Fire rated doors Fire rated door 1 Hour UL#U419 fire barrier Fire Shutter, 1 hour F.E. Fire rated door Occupancy Group S1 A: 22,643 sq ft Occupancy Group S2 A: 1,507 sq ft Occupancy Group B A: 11,076 sq ft Fire Cabinet Fire Cabinet Fire Cabinet Fire Cabinet Fire Cabinet 1 MATCH LINE SEE XX/X-XXX N North SHEET INDEX ID CB1-G100 CB1-G101 CB1-G102 CB1-G103 CB1-C1 CB1-C100 CB1-C200 CB1-C300 CB1-C400 CB1-C500 CB1-C600 CB1-C700 CB1-C800 CB1-C900 CB1-CS1 CB1-CS2 CB1-CS3 CB1-CS4 CB1-CS5 CB1-CS6 CB1-CS7 CB1-WI1 CB1-WI2 CB1-WI3 CB1-WI4 CB1-WI5 CB1-WI6 CB1-L100 CB1-L101 CB1-L102 CB1-L103 CB1-A100 CB1-A101 CB1-A200 CB1-A201 CB1-A202 CB1-A300 CB1-A400 CB1-A500 CB1-A501 CB1-A502 CB1-A600 CB1-A601 CB1-A602 CB1-A603 CB1-A604 CB1-A605 CB1-A700 CB1-A800 CB1-A801 CB1-A900 CB1-A901 CB1-S1-1 CB1-S1-2 CB1-S1-3 CB1-S2-1 CB1-S2-2 CB1-S3-1 CB1-S4-1 CB1-E001 CB1-E100 CB1-E200 CB1-E300 CB1-E301 CB1-E400 CB1-E500 CB1-E601 CB1-E602 CB1-E603 CB1-E701 CB1-M100 CB1-M101 CB1-M102 CB1-M200 CB1-M300 CB1-P001 CB1-P100 CB1-P200 CB1-P300 CB1-P400 CB1-P500 CB1-P600 CB1-P700 Name Cover Sheet-REV 04 ADA/TAS-IFC Project Renderings-IFC Life Safety Plan-ADD 03 Civil-Title Sheet Civil-Paving & Grading Plan-REV 04 Civil-Dimension Plan-REV 04 Civil-Jointing Layout-REV 04 Civil-Drainage Plan-REV 04 Civil-Pollution Prevention Plan & Details-REV 04 Civil-Public Water Line Improvement Plan for Fire Protection-RE... Civil-Water Storm & Sanitary Layout-REV 04 Civil-Storm Water Details Civil-Construction Details City Water Standard Details City Water Standard Details City Water Standard Details City Water Standard Details City Driveway Standard Details City Driveway Standard Details City Driveway Standard Details City Standards-Water Improvements-Title Sheet City Standards-Water Improvements-Water Plan City Standards-Water Improvements-Water Details City Standards-Water Improvements-Water Details City Standards-Water Improvements-Water Details City Standards-Water Improvements-Water Details Landscape Plan Landscape-Irrigation Plan Landscape-Details & Notes Landscape-Irrigation Details & Notes Noted Site Plan-REV 04 Site Details-ADD 02 Dimensioned Floor Plan-REV 04 Noted Floor Plan-REV 04 Car Wash Building & Mechanical Mezzanine-REV 04 Roof Plan-IFC Exterior Elevations-REV 04 Building Sections-REV 04 Building Sections-ADD 01 Wall Sections-ADD 01 Architectural Finishes and Specifications-ADD 01 Room Finish Schedule-REV 04 Door Schedule and Legend-REV 04 Door Legend Continued-REV 04 Window Legend-ADD 01 Door and Window Details-ADD 01 RCP-REV 04 Enlarged Plans and Interior Elevations-ADD 01 Enlarged Plans and Interior Elevations-IFC Furniture and Fixture Plan-REV 04 Finish Floor Plan-REV 04 Structural-Foundation Plan-REV 04 Structural-Schematic Roof Framing Plan-REV 04 Structural-Car Wash Foundation & Mezzanine Framing-REV 04 Structural-Foundation Details-REV 04 Structural-Foundation Details Structural-Framing Details Structural-General Notes Electrical-Site Plan-REV 04 Electrical-Lighting Plan-REV 04 Electrical-Power Plan-REV 04 Electrical-Car Wash & Mezzanine Plans-REV 04 Electrical-Car Wash Power Plan-REV 04 Electrical-Special Systems Plan Electrical-One Line Riser Diagram & Load Analysis-REV 04 Electrical-Schedules-REV 04 Electrical-Schedules-REV 04 Electrical-Schedules-REV 04 Electrical-Details Mechanical-Floor Plan-REV 04 Mechanical-Enlarged Floor Plan Mechanical-Roof Plan Mechanical-Schedules-REV 04 Mechanical-Details Plumbing-Site Plan-REV 04 Plumbing-DWV Floor Plan-REV 04 Plumbing-Water Floor Plan-REV 04 Plumbing-Roof Plan Plumbing-Car Wash & Mezzanine Plans-REV 04 Plumbing-Schedules Plumbing-Details Plumbing-Riser Diagrams SCALE: 1/16" = 1'-0" A4 CB1-Rated Plan CB1-G100 0" C1 A800 C1 A800 C1 A800 A 100A A C1 A800 Project Site Existing Toyota Dealership Hicks Family Nissan Robstown, TX Design Criteria/Facility Data: List of Abbreviations: ACI American Concrete Institute AFF Above Finish Floor AISC American Institute of Steel construction ALUM Aluminum ANSI American National Standards Institute APPROX Approximate ASHRAE American Society of Heating, Refrigeration, & AC Engineers ASME American Society of Mechanical Engineers ASTM American Society for Testing Materials BD Board BLDG Building CI Contractor Installed CJ Control Joint; Construction Joint CL Center Line CMU Concrete Masonry Unit COL Column CONC Concrete CONT Continuous CP Contractor Provided CSI Construction Specifications Institute C.O. Cased Opening D Depth DET Detail DIA Diameter DIM Dimension DTLS Details DWGS Drawings EA Each EJ Expansion Joint ELEC Electrical EQ Equal EV Electric Vehicle Charging Station EXIST Existing EXP Exposed EXP JT Expansion Joint FF Finished Floor F.H. Fire Hydrant FL Flow Line GA Gauge GALV Galvanized GYP BD Gypsum Board H.B. Hose Bibb HC Handicapped H.D.G. Hot Dipped Galvanized HOR Horizontal HR Hour HT Height HVAC Heating, Ventilation, Air-Conditioning IN Inch J-Box Junction Box JAN Janitor JT Joint MANUF Manufacturer MAT Material MAX Maximum MECH Mechanical MEP Mechanical, Electrical, Plumbing MIN Minimum MISC Miscellaneous MTD Mounted MTL Metal N North NA Not Applicable NIC Not In Contract OC On Center OI Owner Installed OP Owner Provided OPP Opposite PLBG Plumbing PLYWD Plywood PSF Pounds per Square Foot PSI Pounds per Square Inch PTD Painted PVC Polyvinyl Chloride R Riser, Radius RAD Radius RE Refer REINF Reinforcement REQ Required SBC Standard Building Code SCHED Schedule SHT Sheet SIM Similar SPEC Specified, Specifications SQ FT/SF Square Feet STL Steel STRUCT Structural Symbol Legend: Revision Tag Match Line North Arrow Elevation Marker Height Marker Section Marker Window Tag Door Tag Wall Tag Detail/ Enlarged Plan Tag Objects above or Hidden Vicinity Map: Rated Plan: Civil : Urban Engineering 2725 Swantner Dr. Corpus Christi, TX 78404 phone: 361.854.3101 fax:361.854.6001 Attn. Mr. Murf Hudson, P.E. Geotechnical : Rock Engineering & Testing Lab., Inc. 6817 Leopard Street Corpus Christi, TX 78409 phone: 361.883.4555 fax:361.883.4711 Attn. Mr. Mark Rock, P.E. MEP : NRG Engineering 5656 S. Staples, Ste. 360 Corpus Christi, TX 78411 phone: 361.852.2727 fax: 361.852.2922 Attn. Mr. John Rodriguez, P.E. Architect : EDR Architects, PLLC 4949 Everhart, Ste. 104B Corpus Christi, TX 78411 phone: 361.452.1683 fax: 361.452.1967 Attn. Emily D. Rozypal, AIA Structural & Windstorm : REM Engineering 6800 Park Ten Blvd., Ste. 239E San Antonio, TX 78213 phone: 210.320.1199 fax: Attn. Robert E. Martinez, P.E. Project Team: Landscape Architect : Gignac Landscape 3833 S. Staples, ste. N-119 Corpus Christi, tX 78411 phone: 361.853.0795 fax:361.814.0195 Attn. Mr. Robert Gignac Address: 3202 I-69 north frontage road, Robstown, TX 78380 Property Description: CAH-DHL Commercial Track, Block 1, Lot 1 Legal Description: 6.01 Acres, situated in the Gregorio Farias Grant, A-592, being out of a 15.23 Acre Tract of land described in Special Warranty Deed with Vendor's Lien, from C.C. Deluxe Properties, Ltd., a Texas limited liability partnership, Successor by Merger with Deluxe Properties, a Texas General Partnership to CAH-DHL Properties, LLC, a Texas limited liability company, recorded in Document No. 2015008171 < tel : 2015008171 > , Official Public Records of Nueces County, Texas. Project Description: New Construction Single Story Automobile Dealership with a detached car wash Building Code: International Building Code 2009 Site Zone: CG-2 Building Area: Allowed: 23,000 sq.ft. and 3 stories Actual: 35,226 sq.ft. and 1 story Building Height: Allowed: 55' Actual: 25' Mixed Occupancy: Group B: 11,076 sq.ft. Group S1: 22,643 sq.ft. Group S2: 1,507 sq.ft. Occupant Load: Group B (100 Gross): 11,076/100=110 Occupants Group S1 (300 gross): 22,643/300=75 Occupants Group S2 (300 gross): 1,507/300=5 Occupants Total Occupant Load: 119 Occupants Separation Requirements: Group B to Group S-1: No Occupancy separation requirement, but fire separation requirement of 3 hours for over 12,000 sq.ft. Building shall be sprinkled, so fire separation requirement will be 2 hours in lieu of 3 hours. Construction Classification: Type II-B Plumbing Fixture Count: Water Closets Required: Group B: 4 Group S: 1 Water Closets Provided: 9 Lavatories Required: Group B: 3 Group S: 1 Lavatories Provided: 7 Drinking Fountains Required: Group B: 2 Group S: 1 Drinking Foundains Provided: 4 Service Sinks Required: 1 Service Sinks Provided: 1 Sprinkled: Yes Fire Extinguishers: Max Travel: 75' Distance from property lines and Adjacent Buildings: Plan North: >30' Plan South: >30' Plan East: >30' Plan West: >30' Parking Requirements: UDC Requirement: Vehicle Sales & Service: 1 per 500 indoor sq.ft. of gross floor area, plus 1 per 10,000 sq.ft. outdoor lot area. 35,226 sq.ft. of building/500= 71 parking spaces 193,100 sq.ft. of Lot/10,000= 20 parking spaces Required: 71 spaces ( 3 H . C .) Inventory : 20 spaces ( H . C . not required ) Total: 91 spaces Accessibility : Sue Corey P.O. Box 3156 Corpus Christi, TX 78463 phone: 361.994.1331 Attn. Sue Corey, RAS Owner : CAH-DHL Automotive, LLC Hicks Family Nissan 2149 IH-69 Access Road Robstown, TX 78380 phone: 361.654.7255 fax: 361.654.1955 Attn. Mr. Charlie Hicks T.O.B. Top of Beam T.O.P. Top of Plate TYP Typical UL Underwriters' Laboratories, Inc. UNO Unless Noted Otherwise V Volt VA Volt Amperes W Width W/ With WD Wood WWM Welded Wire Mesh @ At Site Location:

Hicks Family Nissan - Barcombarcom.cc/wp-content/uploads/2016/06/Hicks-Family-Nissan...CB1-M100 CB1-M101 CB1-M102 CB1-M200 CB1-M300 CB1-P001 CB1-P100 CB1-P200 CB1-P300 CB1-P400 CB1-P500

Embed Size (px)

Citation preview

Page 1: Hicks Family Nissan - Barcombarcom.cc/wp-content/uploads/2016/06/Hicks-Family-Nissan...CB1-M100 CB1-M101 CB1-M102 CB1-M200 CB1-M300 CB1-P001 CB1-P100 CB1-P200 CB1-P300 CB1-P400 CB1-P500

Proj

ect A

ddre

ss:

Proj

ect D

ata

Cov

er S

heet

-REV

04 Shee

t Titl

e

1500

3Pr

ojec

t No:

Issu

e

Hic

ks F

amily

Nis

san

Proj

ect N

ame:

Dat

e:

3202

IH-6

9 N

orth

Fron

tage

Rd.

, Rob

stow

n,TX

, 783

80, C

ount

y

D

C

B

A

1 2 3 4 5

Cop

yrig

ht©

201

5

GC

B1-

G10

0

C:\E

DR

Pro

ject

s\15

003

Hic

ks R

obst

own

Prop

erty

\Arc

hiC

AD

\Non

Issu

ed-0

04 A

DD

-Hic

ks-IF

C.p

ln

1

6

1 2 3 4 5 6

E

phon

e: 3

61.5

37.4

400

ero

zypa

l@ed

rarc

hite

cts.

com

Oct

ober

14,

201

5IF

C-O

ctob

er 1

4, 2

015

01 R

EV-O

ctob

er 2

7, 2

015

02 R

EV-N

ovem

ber 3

, 201

5

03 R

EV-N

ovem

ber 1

6, 2

015

04 R

EV-F

ebru

ary

10, 2

016

Rev

isio

n

1234

CB1149A

CB1149E

CB1100B

CB1148A

CB1151

CB1-144ERated

CB1-129ARated

CB1152B

CB1103A

CB1103D

CB1103E

CB1100A

CB1148D

CB1148E

CB1148C

CB1144A

CB1152A

CB1150D

CB1-134BRated

CB1129B

CB1133

CB1130B

CB1148B

CB1-138Rated

CB1149F

CB1149B

CB1149J

CB1149H

CB1149I

CB1150A

CB1150B

CB1150C

CB1-136Rated

CB1153A

CB1152C

F.E. F.E.

F.E.

F.E.

F.E.Fire Shutter, 2 hour

F.E.

F.E.

F.E.

F.E.

F.E.

2 Hour UL#U419fire barrier(Reduced 1 hour dueto sprinkler system)

1 Hour UL#U419fire barrier

2 Hour UL#U419fire barrier(Reduced 1 hour dueto sprinkler system)

Fire rated doorFire rated doors

Fire rated doorsFire rateddoor

1 Hour UL#U419fire barrier

Fire Shutter, 1 hour

F.E.

Fire rateddoor

Occupancy Group S1A: 22,643 sq ft

Occupancy Group S2A: 1,507 sq ft

Occupancy Group BA: 11,076 sq ft

Fire Cabinet

Fire Cabinet

Fire Cabinet

Fire Cabinet

Fire

Cab

inet

1

MATCH LINESEE XX/X-XXX

N

Nor

th

SHEET INDEXID

CB1-G100

CB1-G101

CB1-G102

CB1-G103

CB1-C1

CB1-C100

CB1-C200

CB1-C300

CB1-C400

CB1-C500

CB1-C600

CB1-C700

CB1-C800

CB1-C900

CB1-CS1

CB1-CS2

CB1-CS3

CB1-CS4

CB1-CS5

CB1-CS6

CB1-CS7

CB1-WI1

CB1-WI2

CB1-WI3

CB1-WI4

CB1-WI5

CB1-WI6

CB1-L100

CB1-L101

CB1-L102

CB1-L103

CB1-A100

CB1-A101

CB1-A200

CB1-A201

CB1-A202

CB1-A300

CB1-A400

CB1-A500

CB1-A501

CB1-A502

CB1-A600

CB1-A601

CB1-A602

CB1-A603

CB1-A604

CB1-A605

CB1-A700

CB1-A800

CB1-A801

CB1-A900

CB1-A901

CB1-S1-1

CB1-S1-2

CB1-S1-3

CB1-S2-1

CB1-S2-2

CB1-S3-1

CB1-S4-1

CB1-E001

CB1-E100

CB1-E200

CB1-E300

CB1-E301

CB1-E400

CB1-E500

CB1-E601

CB1-E602

CB1-E603

CB1-E701

CB1-M100

CB1-M101

CB1-M102

CB1-M200

CB1-M300

CB1-P001

CB1-P100

CB1-P200

CB1-P300

CB1-P400

CB1-P500

CB1-P600

CB1-P700

NameCover Sheet-REV 04

ADA/TAS-IFC

Project Renderings-IFC

Life Safety Plan-ADD 03

Civil-Title Sheet

Civil-Paving & Grading Plan-REV 04

Civil-Dimension Plan-REV 04

Civil-Jointing Layout-REV 04

Civil-Drainage Plan-REV 04

Civil-Pollution Prevention Plan & Details-REV 04

Civil-Public Water Line Improvement Plan for Fire Protection-RE...

Civil-Water Storm & Sanitary Layout-REV 04

Civil-Storm Water Details

Civil-Construction Details

City Water Standard Details

City Water Standard Details

City Water Standard Details

City Water Standard Details

City Driveway Standard Details

City Driveway Standard Details

City Driveway Standard Details

City Standards-Water Improvements-Title Sheet

City Standards-Water Improvements-Water Plan

City Standards-Water Improvements-Water Details

City Standards-Water Improvements-Water Details

City Standards-Water Improvements-Water Details

City Standards-Water Improvements-Water Details

Landscape Plan

Landscape-Irrigation Plan

Landscape-Details & Notes

Landscape-Irrigation Details & Notes

Noted Site Plan-REV 04

Site Details-ADD 02

Dimensioned Floor Plan-REV 04

Noted Floor Plan-REV 04

Car Wash Building & Mechanical Mezzanine-REV 04

Roof Plan-IFC

Exterior Elevations-REV 04

Building Sections-REV 04

Building Sections-ADD 01

Wall Sections-ADD 01

Architectural Finishes and Specifications-ADD 01

Room Finish Schedule-REV 04

Door Schedule and Legend-REV 04

Door Legend Continued-REV 04

Window Legend-ADD 01

Door and Window Details-ADD 01

RCP-REV 04

Enlarged Plans and Interior Elevations-ADD 01

Enlarged Plans and Interior Elevations-IFC

Furniture and Fixture Plan-REV 04

Finish Floor Plan-REV 04

Structural-Foundation Plan-REV 04

Structural-Schematic Roof Framing Plan-REV 04

Structural-Car Wash Foundation & Mezzanine Framing-REV 04

Structural-Foundation Details-REV 04

Structural-Foundation Details

Structural-Framing Details

Structural-General Notes

Electrical-Site Plan-REV 04

Electrical-Lighting Plan-REV 04

Electrical-Power Plan-REV 04

Electrical-Car Wash & Mezzanine Plans-REV 04

Electrical-Car Wash Power Plan-REV 04

Electrical-Special Systems Plan

Electrical-One Line Riser Diagram & Load Analysis-REV 04

Electrical-Schedules-REV 04

Electrical-Schedules-REV 04

Electrical-Schedules-REV 04

Electrical-Details

Mechanical-Floor Plan-REV 04

Mechanical-Enlarged Floor Plan

Mechanical-Roof Plan

Mechanical-Schedules-REV 04

Mechanical-Details

Plumbing-Site Plan-REV 04

Plumbing-DWV Floor Plan-REV 04

Plumbing-Water Floor Plan-REV 04

Plumbing-Roof Plan

Plumbing-Car Wash & Mezzanine Plans-REV 04

Plumbing-Schedules

Plumbing-Details

Plumbing-Riser Diagrams

SCALE: 1/16" = 1'-0"

A4 CB1-Rated PlanCB1-G100

0"

C1A800

C1A800

C1A800

A

100A

A

C1A800

ProjectSite

Existing ToyotaDealership

Hicks Family NissanRobstown, TX

Design Criteria/Facility Data: List of Abbreviations:ACI American Concrete InstituteAFF Above Finish FloorAISC American Institute of Steel constructionALUM AluminumANSI American National Standards InstituteAPPROX ApproximateASHRAE American Society of Heating, Refrigeration, & AC EngineersASME American Society of Mechanical EngineersASTM American Society for Testing Materials

BD BoardBLDG Building

CI Contractor InstalledCJ Control Joint; Construction JointCL Center LineCMU Concrete Masonry UnitCOL ColumnCONC ConcreteCONT ContinuousCP Contractor ProvidedCSI Construction Specifications InstituteC.O. Cased Opening

D DepthDET DetailDIA DiameterDIM DimensionDTLS DetailsDWGS Drawings

EA EachEJ Expansion JointELEC ElectricalEQ EqualEV Electric Vehicle Charging StationEXIST ExistingEXP ExposedEXP JT Expansion Joint

FF Finished FloorF.H. Fire HydrantFL Flow Line

GA GaugeGALV GalvanizedGYP BD Gypsum Board

H.B. Hose BibbHC HandicappedH.D.G. Hot Dipped GalvanizedHOR HorizontalHR HourHT HeightHVAC Heating, Ventilation, Air-Conditioning

IN Inch

J-Box Junction BoxJAN JanitorJT Joint

MANUF ManufacturerMAT MaterialMAX MaximumMECH MechanicalMEP Mechanical, Electrical, PlumbingMIN MinimumMISC MiscellaneousMTD MountedMTL Metal

N NorthNA Not ApplicableNIC Not In Contract

OC On CenterOI Owner InstalledOP Owner ProvidedOPP Opposite

PLBG PlumbingPLYWD PlywoodPSF Pounds per Square FootPSI Pounds per Square InchPTD PaintedPVC Polyvinyl Chloride

R Riser, RadiusRAD RadiusRE ReferREINF ReinforcementREQ Required

SBC Standard Building CodeSCHED ScheduleSHT SheetSIM SimilarSPEC Specified, SpecificationsSQ FT/SF Square FeetSTL SteelSTRUCT Structural

Symbol Legend:

Revision Tag

Match Line

North Arrow

Elevation Marker

Height Marker

Section Marker

Window Tag

Door Tag

Wall Tag

Detail/ Enlarged PlanTag

Objects above orHidden

Vicinity Map:

Rated Plan:Civil:

Urban Engineering2725 Swantner Dr.Corpus Christi, TX 78404phone: 361.854.3101fax:361.854.6001Attn. Mr. Murf Hudson, P.E.

Geotechnical:

Rock Engineering & Testing Lab., Inc.6817 Leopard StreetCorpus Christi, TX 78409phone: 361.883.4555fax:361.883.4711Attn. Mr. Mark Rock, P.E.

MEP:

NRG Engineering5656 S. Staples, Ste. 360Corpus Christi, TX 78411phone: 361.852.2727fax: 361.852.2922Attn. Mr. John Rodriguez, P.E.

Architect:

EDR Architects, PLLC4949 Everhart, Ste. 104BCorpus Christi, TX 78411phone: 361.452.1683fax: 361.452.1967Attn. Emily D. Rozypal, AIA

Structural &Windstorm:

REM Engineering6800 Park Ten Blvd., Ste. 239ESan Antonio, TX 78213phone: 210.320.1199fax:Attn. Robert E. Martinez, P.E.

Project Team:

Landscape Architect:

Gignac Landscape3833 S. Staples, ste. N-119Corpus Christi, tX 78411phone: 361.853.0795fax:361.814.0195Attn. Mr. Robert Gignac

Address: 3202 I-69 north frontage road, Robstown, TX 78380Property Description: CAH-DHL Commercial Track, Block 1, Lot 1

Legal Description: 6.01 Acres, situated in the Gregorio Farias Grant, A-592, being out of a 15.23 Acre Tract ofland described in Special Warranty Deed with Vendor's Lien, from C.C. Deluxe Properties, Ltd., a Texas limitedliability partnership, Successor by Merger with Deluxe Properties, a Texas General Partnership to CAH-DHLProperties, LLC, a Texas limited liability company, recorded in Document No. 2015008171 <tel:2015008171>,Official Public Records of Nueces County, Texas.

Project Description: New Construction Single Story Automobile Dealership with a detached car wash

Building Code: International Building Code 2009Site Zone: CG-2Building Area: Allowed: 23,000 sq.ft. and 3 stories Actual: 35,226 sq.ft. and 1 story Building Height: Allowed: 55' Actual: 25'

Mixed Occupancy: Group B: 11,076 sq.ft. Group S1: 22,643 sq.ft. Group S2: 1,507 sq.ft. Occupant Load: Group B (100 Gross): 11,076/100=110 Occupants Group S1 (300 gross): 22,643/300=75 Occupants Group S2 (300 gross): 1,507/300=5 Occupants Total Occupant Load: 119 Occupants

Separation Requirements: Group B to Group S-1: No Occupancy separation requirement, but fire separation requirement of 3 hours for over 12,000 sq.ft. Building shall be sprinkled, so fire separation requirement will be 2 hours in lieu of 3 hours. Construction Classification: Type II-B

Plumbing Fixture Count: Water Closets Required: Group B: 4 Group S: 1 Water Closets Provided: 9 Lavatories Required: Group B: 3 Group S: 1 Lavatories Provided: 7 Drinking Fountains Required: Group B: 2 Group S: 1 Drinking Foundains Provided: 4 Service Sinks Required: 1 Service Sinks Provided: 1 Sprinkled: Yes

Fire Extinguishers: Max Travel: 75'

Distance from property lines and Adjacent Buildings: Plan North: >30' Plan South: >30' Plan East: >30' Plan West: >30'

Parking Requirements: UDC Requirement: Vehicle Sales & Service: 1 per 500 indoor sq.ft. of gross floor area,plus 1 per 10,000 sq.ft. outdoor lot area.35,226 sq.ft. of building/500= 71 parking spaces193,100 sq.ft. of Lot/10,000= 20 parking spaces

Required: 71 spaces (3 H.C.)Inventory: 20 spaces (H.C. not required)Total: 91 spaces

Accessibility:

Sue CoreyP.O. Box 3156Corpus Christi, TX 78463phone: 361.994.1331Attn. Sue Corey, RAS

Owner:

CAH-DHL Automotive, LLCHicks Family Nissan2149 IH-69 Access RoadRobstown, TX 78380phone: 361.654.7255fax: 361.654.1955Attn. Mr. Charlie Hicks

T.O.B. Top of BeamT.O.P. Top of PlateTYP Typical

UL Underwriters' Laboratories, Inc.UNO Unless Noted Otherwise

V VoltVA Volt Amperes

W WidthW/ WithWD WoodWWM Welded Wire Mesh

@ At

Site Location: