High Power Pulsed I-V
powered by
FOCUS MICROWAVES GROUP
Auriga’s 5th Generation 1200V and 2000V PIV Systems
P U L S E D I V
V08/18
1200V / 10 or 100A DRAIN PULSER
The PHD1200 supports the industry’s most advanced high-powered devices. Leveraging recent breakthroughs in component and pulser-circuit technology provides unparalleled speed, accuracy, and resolution. Dynamic on-resistance of the latest transistors can now be measured with precision.The PHD1200 operates with the AU-5 Pulsed IV/RF Characterization System; this compact and versatile test solution accurately simulates real life and delivers unparalleled performance, capturing measurements with incredible accuracy and speed.
1200V
www.focus-microwaves.com2
ModelMax Voltage
(V)Max Current
Pulsed (A)Typical Error Max Power (W)
Min. Pulse Width
Max PRFMin. Output
Rise /Fall
PHD1200-10 1200 10 0.01% 5000 1us 1.4 kHz @ 1200V 84ns*
3.525
4.700
8.000
8.000
3.176
-200
0
200
400
600
800
1000
1200
1400
0.00E+00 5.00E-07 1.00E-06 1.50E-06 2.00E-06 2.50E-06 3.00E-06 3.50E-06 4.00E-06 4.50E-06
1200V Pulsed Waveforms
time (seconds)
40A Pulsed Waveforms
time (seconds)
cu
rre
nt
-5
0
5
10
15
20
25
30
35
40
45
0.00E+00 1.00E-06 2.00E-06 3.00E-06 4.00E-06 5.00E-06 6.00E-06 7.00E-06
volt
age
PHD1200-100 1200 100 0.01% 5000 1us 1.4 kHz @ 1200V 84ns*
*Measure with open circuit
3www.focus-microwaves.com
2000V
ModelMax Voltage
(V)Max Current
Pulsed (A)Typical Error Max Power (W)
Min. Pulse Width
Max PRFMin. Output
Rise /Fall
PHD2000-10 2000 10 0.01% 5000 4us 1.0 kHz @ 2000V 84ns*
2000V / 10 or 100A DRAIN PULSER
As GaN and other non traditional technologies continue to make inroads in high power appli-cations, design and test engineers will require high performance robust narrow pulsed IV solutions. Auriga’s new PHD2000drain puls-er head, available with the newly redesigned AU-5 Pulsed I-V measurement system, allows for pulsed measurements up to 2000V and 100A. This new high voltage offering intro-duced to the market is due to increasing demand from various industry verticals which include Automotive, Medical, Industrial, and Telecommunications.
2000V Pulsed Waveforms
time (seconds)
volt
age
100A Pulsed Waveforms
time (seconds)
cu
rre
nt
-20
0
20
40
60
80
100
120
0.00E+00 1.00E-06 2.00E-06 3.00E-06 4.00E-06 5.00E-06 6.00E-06 7.00E-06 8.00E-06 9.00E-06
-100
400
900
1400
1900
2400
0.00E+00 1.00E-06 2.00E-06 3.00E-06 4.00E-06 5.00E-06 6.00E-06 7.00E-06 8.00E-06 9.00E-06 1.00E-05
PHD2000-100 2000 100 0.01% 5000 4us 1.0 kHz @ 2000V 84ns*
*Measure with open circuit
[email protected] www.focus-microwaves.com+1 514 684 4554
Intuitive Graphic User InterfaceAuriga version 5.1
4
±100VPulser Gate
1200V / 2000VPulser Drain
Auriga AU5 Mainframe
DUTDC High Voltage Power Supplies
FCU
Auriga software interface displaying dynamic On-resistance measurement
Typical setup for High Powered Pulsed I/V