22
History November 7, 2001

History November 7, 2001. STORET 1963 Honeywell 400 Assembler and Autocoder Data Storage by Drum Public Health Service, Cincinnati OH Andy Breidenbach,

Embed Size (px)

Citation preview

Page 1: History November 7, 2001. STORET 1963 Honeywell 400 Assembler and Autocoder Data Storage by Drum Public Health Service, Cincinnati OH Andy Breidenbach,

History

November 7, 2001

Page 2: History November 7, 2001. STORET 1963 Honeywell 400 Assembler and Autocoder Data Storage by Drum Public Health Service, Cincinnati OH Andy Breidenbach,

STORET 1963

• Honeywell 400

• Assembler and Autocoder

• Data Storage by Drum

• Public Health Service, Cincinnati OH

• Andy Breidenbach, Sted Green, Clarence Tutwiler

Page 3: History November 7, 2001. STORET 1963 Honeywell 400 Assembler and Autocoder Data Storage by Drum Public Health Service, Cincinnati OH Andy Breidenbach,

STORET 1968

• IBM 360/50, OS MVT

• PL/I and Assembler

• Data Cell Storage

• Department of Interior, Federal Water Pollution Control Administration.

Page 4: History November 7, 2001. STORET 1963 Honeywell 400 Assembler and Autocoder Data Storage by Drum Public Health Service, Cincinnati OH Andy Breidenbach,

STORET 1971

• IBM 360/65, OS MVT

• PL/I and Assembler

• Hard disk storage

• Department of Interior, Federal Water Pollution Control Administration.

• Leased Time Sharing capacity, dial-up access.

Page 5: History November 7, 2001. STORET 1963 Honeywell 400 Assembler and Autocoder Data Storage by Drum Public Health Service, Cincinnati OH Andy Breidenbach,

STORET 1973

• IBM 360/65, OS MVT, TSO

• PL/I, Fortran and Assembler

• Leased Time Sharing capacity, dial-up access.

• Automated User Front End.

Page 6: History November 7, 2001. STORET 1963 Honeywell 400 Assembler and Autocoder Data Storage by Drum Public Health Service, Cincinnati OH Andy Breidenbach,

STORET 1975

• IBM 360/65, OS MVT, COMNET ALPHA, NIH WYLBUR

• PL/I, Fortran and Assembler

• Leased Time Sharing capacity, dial-up access.

• User Front End Lost

Page 7: History November 7, 2001. STORET 1963 Honeywell 400 Assembler and Autocoder Data Storage by Drum Public Health Service, Cincinnati OH Andy Breidenbach,

STORET 1980

• IBM MVS, TSO

• PL/I, Fortran and Assembler

• In House Computer, EPA/NCC/RTP

• User Front End Back

Page 8: History November 7, 2001. STORET 1963 Honeywell 400 Assembler and Autocoder Data Storage by Drum Public Health Service, Cincinnati OH Andy Breidenbach,

STORET 1984

• In House Computer, EPA/NCC/RTP

• STORET Control moved from Water to Information Management

• Development de-emphasized, Operations Stabilized.

• Pass the million station mark.

Page 9: History November 7, 2001. STORET 1963 Honeywell 400 Assembler and Autocoder Data Storage by Drum Public Health Service, Cincinnati OH Andy Breidenbach,

STORET 1991

• STORET Responsibility Returns to OW

• Vision for the Future

• Modernization effort begins

Page 10: History November 7, 2001. STORET 1963 Honeywell 400 Assembler and Autocoder Data Storage by Drum Public Health Service, Cincinnati OH Andy Breidenbach,

STORET 1993

• Requirements documented

• 17 Joint Design Sessions with Clients

• Data Modeling Begins

Page 11: History November 7, 2001. STORET 1963 Honeywell 400 Assembler and Autocoder Data Storage by Drum Public Health Service, Cincinnati OH Andy Breidenbach,

STORET 1996

• STORET Business Requirement captured in CASE technology

• Software Code Generated by CASE Tool

• Final Prototype confirmed by Users

• Clarence Tutwiler dies.

Page 12: History November 7, 2001. STORET 1963 Honeywell 400 Assembler and Autocoder Data Storage by Drum Public Health Service, Cincinnati OH Andy Breidenbach,

STORET 1996

• Prototype v 4.1 (Final)

• IBM OS/2 Operating System, IBM DB-2/2 Database Engine, COBOL code

• Converted to Windows 95, Oracle Database engine, C++ code

• Three working days.

Page 13: History November 7, 2001. STORET 1963 Honeywell 400 Assembler and Autocoder Data Storage by Drum Public Health Service, Cincinnati OH Andy Breidenbach,

STORET 1998

• Production version 1.0

• Generated by CASE Tool

• Oracle, Windows 95, C++

• 500 Copies distributed

• STORET Web Site first appears

Page 14: History November 7, 2001. STORET 1963 Honeywell 400 Assembler and Autocoder Data Storage by Drum Public Health Service, Cincinnati OH Andy Breidenbach,

STORET 1999

• Production version 1.1

• Generated by CASE Tool

• Oracle, Windows 95, Windows NT

• 1000 Copies distributed

• STORET Web Site offers Data Query

• Legacy STORET goes up on the Web

Page 15: History November 7, 2001. STORET 1963 Honeywell 400 Assembler and Autocoder Data Storage by Drum Public Health Service, Cincinnati OH Andy Breidenbach,

STORET 2000

• Production version 1.2

• Generated by CASE Tool

• Oracle, Windows 95/98, Windows NT

• Distributed via the Internet

• STORET Web Site 100% Functional

• Mainframe Legacy System Shut Down

Page 16: History November 7, 2001. STORET 1963 Honeywell 400 Assembler and Autocoder Data Storage by Drum Public Health Service, Cincinnati OH Andy Breidenbach,

STORET 2001

• Production version 2.0 in Preliminary Testing

• Generated by CASE Tool

• Windows 95/98/me, Windows NT,2000

• Oracle 8i

• Version 1.2 now on CD-ROM

Page 17: History November 7, 2001. STORET 1963 Honeywell 400 Assembler and Autocoder Data Storage by Drum Public Health Service, Cincinnati OH Andy Breidenbach,

STORET 2001

• SIM 1.2 in Final Testing

• Reporting Software 1.2 Distributed via CD-ROM

• Preliminary steps toward full EDAS integration

Page 18: History November 7, 2001. STORET 1963 Honeywell 400 Assembler and Autocoder Data Storage by Drum Public Health Service, Cincinnati OH Andy Breidenbach,

STORET 2001

• Office of Water designates STORET as its Primary Repository for Monitoring Data.

• STORET Version 2 Design Finalized

Page 19: History November 7, 2001. STORET 1963 Honeywell 400 Assembler and Autocoder Data Storage by Drum Public Health Service, Cincinnati OH Andy Breidenbach,

STORET 2002

• STORET Production Version 2.0 Completed.

• STORET Web Site, Reporting Module, and SIM upgraded to version 2.0.

• Version 3 Design Phase Begins.

Page 20: History November 7, 2001. STORET 1963 Honeywell 400 Assembler and Autocoder Data Storage by Drum Public Health Service, Cincinnati OH Andy Breidenbach,

STORET Beyond 2002

• CASE Tool Technology Abandoned

• Oracle Designer/Developer Adopted

• Full use of Database Constraints

• Database Events will Trigger Imbedded Software, Validity Checking

• Monolithic Single Module Approach Abandoned.

Page 21: History November 7, 2001. STORET 1963 Honeywell 400 Assembler and Autocoder Data Storage by Drum Public Health Service, Cincinnati OH Andy Breidenbach,

STORET Beyond 2002

• Retrieval and Analysis Software Development Takes Center Stage

• Third Party Software Role Increases

• EPA Staff Mix Changing to Acquire Needed Skills

Page 22: History November 7, 2001. STORET 1963 Honeywell 400 Assembler and Autocoder Data Storage by Drum Public Health Service, Cincinnati OH Andy Breidenbach,

2005

Lee RetiresLee Retires

Any Questions ?Any Questions ?