Live loads specified in codes do account for ordinaryimpact loads When structural members are subject to unusual
vibration or impact we have to account for themoutside the code specs
8/10/2019 Hoist Loads
2/44
Type ofmember
Source of Impact Percentincrease
Supporting Elevators and elevator machinery 100Supporting Light machines, shaft, or motor driven 20Supporting Reciprocating machines or power-driven
units50
Hangers Floors or balconies 33
8/10/2019 Hoist Loads
3/44
Structures supporting cranes:Maximum wheel loads Allowance for impactMultiple cranesTraction and braking forcesUse of crane stopsCyclic loading / Fatigue
Crane live load is its fully rated capactity
8/10/2019 Hoist Loads
4/44
8/10/2019 Hoist Loads
5/44
8/10/2019 Hoist Loads
6/44
Max vertical wheel loadMonorail, cab operated, remote operated
increased by 25% for impactPendant operated overhead
Increased by 10% for impact
Impact increases do not have to be applied tosupporting columns, only runway
8/10/2019 Hoist Loads
7/44
Electic powered trolleys 20% (crane rated load + trolley weight + hoist weight) Assume applied by wheels at top of rails Acts normal to the railsDistributed, as appropriate to stiffness of rail support
Bridge or monorail with hand-gearingNo need for lateral load increase
8/10/2019 Hoist Loads
8/44
Runway must be designed for stop forces Velocity of crane at impact taken into accountFatigue and serviceability concerns
AISC Design Guide 7 AISE Standard No. 13
8/10/2019 Hoist Loads
9/44
Caused by changes in dimensions/geometry ofstructures due to
Behavior of materialType of framingDetails of construction
e.g.Foundation settlement
Temperature changesShrinkage restrained by adjoining structures
8/10/2019 Hoist Loads
10/44
Loads may act simultaneouslyBuilding codes specify various combinations that mustbe considered
Depends on whether allowable stress design (ASD) orLoad and Resistance Factor Design (LRFD) is usedSEI/ASCE 7-02 provides guidance.
8/10/2019 Hoist Loads
11/44
D = dead loadL = live floor load, including impactLr = roof live load
S = roof snow loadR = rain load (initial rainwater or ice, exclusive of ponding) W = wind loadE = earthquake loadT = restraint load
8/10/2019 Hoist Loads
12/44
DD + L + TD + (Lr or S or R)
0.75 [ L + (Lr or S or R) + T ] + D0.75 (W or 0.7E) + D0.75 [ L + (W or 0.7E) + (Lr or S or R) ] + D0.6D + W0.6D + 0.7E
Because E was calculated for LRFD it is reduced by 0.7for ASD design.
8/10/2019 Hoist Loads
13/44
1.4 D1.2(D+T) + 1.6L + 0.5(Lr or S or R)1.2D + 1.6(Lr or S or R) + (L or 0.8W)
1.2D + 1.6W + L + 0.5(Lr or S or R)1.2D + E + (L or 0.2S)0.9D + 1.6W0.9D + E
8/10/2019 Hoist Loads
14/44
International Building CodeInternational Code Council, Falls Church, VA
NFPA 5000, Building Construction and Safety Code
National Fire Protection Association, Quincy, MANational Building Code of CanadaNational Research Council of Canada, Ottawa, ON
Or local code
8/10/2019 Hoist Loads
15/44
Most fires are accidental or carelessnessStart small and require fuel and ventilation to growNoncombustibles (concrete, steel, brick) are not fuel
Combustibles (paper, wood, plastics) are fuel
8/10/2019 Hoist Loads
16/44
Fire loading is the amount of fuel, measured inequivalent pounds of wood per square foot of floorareaFire severity is the duration of the fire, in hours ofequivalent fire exposureMore modern approaches of fire load are expressed interms of potential heat energy
Fire loading correlates well with fire severity
8/10/2019 Hoist Loads
17/44
8/10/2019 Hoist Loads
18/44
0
1
2
3
4
5
6
7
8
0 10 20 30 40 50 60 70
F i r e
S e v e r i
t y ( h
r s )
Fire Load (lbs/ft2)
8/10/2019 Hoist Loads
19/44
Type of Occupancy Fire Load (lb/ft 2) Fire Severity (hrs) Assembly 5-10 0.5 1Business 5-10 0.5-1Educational 5-10 0.5-1
Hazardous Variable VariableIndustrial
Low hazard 0-10 0-1Moderate hazard 10-25 1-2.5
Institutional 5-10 0.5-1Mercantile 10-20 1-2Residential 5-10 0.5-1Storage
Low hazard 0-10 0-1
Moderate hazard 10-30 1-3
8/10/2019 Hoist Loads
20/44
Fire Resistance : Relative ability of constructionassemblies to prevent spread of fire to adjacent spaces,and to avoid structural collapseFire resistance requirements are a function ofoccupancy and size (height and area)Fire resistance is determined experimentally
ASTM E 119
Uses standard fire exposure Specified in terms of time of exposure
8/10/2019 Hoist Loads
21/44
Time during which an assemblycontinues to prevent spread of fire,does not exceed certain temperature limits, andSustains its structural loads without failure
Typically expressed in hours
Fire Resistance Directory, Underwriters Lab
Fire Resistant Ratings, American Insurance Services Gp.Fire Resistant Design Manual, Gypsum Association
8/10/2019 Hoist Loads
22/44
8/10/2019 Hoist Loads
23/44
No building is fireproof. Avoid this term
8/10/2019 Hoist Loads
24/44
In general, steel can hold 60% of yield strength at1,000 FFailures rarely occur because during a fire building israrely loaded at design load.This is not recognized in the code structures areassumed to be fully loaded during testing.Thus, when building codes specify fire resistant
construction, fire protection materials are required toinsulate the structural steel.
8/10/2019 Hoist Loads
25/44
0
0.2
0.4
0.6
0.8
1
0 500 1000 1500 2000 2500
% Y
i e l d S t r e n g
t h
Temperature (F)
8/10/2019 Hoist Loads
26/44
Gypsum As a plaster, applied over metal lathe or gypsum lathe As wallboard, installed over cold-formed steel framingor furring
Effectiveness can be increased significantly withlightweight mineral aggregates (vermiculite, pearlite)
Mix must be properly proportioned and applied in required
thickness and the lathe correctly installed
8/10/2019 Hoist Loads
27/44
3 kinds:Regular, Type X, and proprietary
Type X:Specially formulated cores for fire resistance.
ProprietarySuch as Typc C, even greater fire resistance
Type of wall board must be specified clearly.
Type and spacing of fasteners (and furring channels ifapplicable) should be in accordance with specs
8/10/2019 Hoist Loads
28/44
8/10/2019 Hoist Loads
29/44
8/10/2019 Hoist Loads
30/44
Most widely usedLightweight mineral fiber and cementitious materialSprayed onto beams, girders, columns, floor decks,
roof decksSFRM: Spray-applied Fire Resistive MaterialsGenerally proprietary formulationsFollow manufacturers recommendations!
Underwriters Laboratories specifies these
8/10/2019 Hoist Loads
31/44
Cohesion/Adhesion are criticalMust be free of dirt, oil, loose scale
Generally light rust is OK
Paint can cause problems
8/10/2019 Hoist Loads
32/44
8/10/2019 Hoist Loads
33/44
8/10/2019 Hoist Loads
34/44
Concrete used to be common, but not highly efficient(weight and thermal conductivity)Concrete floor slabs are common for tops of f lexuralmembers.Concrete sometimes used to encase columns
for architectural or structural purposes,or for protection from abrasion or other physical damage
8/10/2019 Hoist Loads
35/44
8/10/2019 Hoist Loads
36/44
AESS: easthetic choiceSteel Insulation Steel skin
Gives appearance of steel surface but has protection
Water filled tubular columnsPatented in 1884, but not used until 1960 in the 64 storyUS Steel Building in Pittsburgh
Flame shielded spandrel girders
Standard fire test is not representative of the exposurefor exterior structural elements.Can only be used if code allows engineered solutions
8/10/2019 Hoist Loads
37/44
8/10/2019 Hoist Loads
38/44
Columns are interconnected with a water storage tank.In fire, water circulates by convection, keeping thesteel temperature below the critical value of 450C.
This system has economical advantage when applied to
buildings with more than 8 storeys.If the water flow is adequate, the resulting fire resistancetime is virtually unlimited.
In order to prevent freezing, potassium carbonate
(K2CO3) is added to the water.Potassium nitrate is used as an inhibitor againstcorrosion.
8/10/2019 Hoist Loads
39/44
8/10/2019 Hoist Loads
40/44
Interior
ExteriorPainted girder
8/10/2019 Hoist Loads
41/44
8/10/2019 Hoist Loads
42/44
ASTM E119 includes 2 test conditions: Restrained andUnrestrainedRestraint is against thermal expansionThis allows for thermal stresses from surrounding structureMost steel framing is tested as RestrainedUnrestrained:
Single span and simply supported end spans of multiple baysOpen web steel joists or beams, supporting precise units ormetal decking Wood construction
8/10/2019 Hoist Loads
43/44
4
8/10/2019 Hoist Loads
44/44
0
0.5
1
1.5
2
2.5
3
3.5
4
0.5 1.5 2.5 3.5
F i r e
R e s i s t a n c e
( h r s
)
W/D (lb/ft/in)
1/2"5/8"
1"
1 1/4"
1 1/2"
1 7/8"
2"
2 1/2"