Building Sustainability Index www.basix.nsw.gov.au Single Dwelling Certificate number: 840979S This certificate confirms that the proposed development will meet the NSW government's requirements for sustainability, if it is built in accordance with the commitments set out below. Terms used in this certificate, or in the commitments, have the meaning given by the document entitled "BASIX Definitions" dated 29/06/2009 published by the Department. This document is available at www.basix.nsw.gov.au Secretary Date of issue: Friday, 11 August 2017 To be valid, this certificate must be lodged within 3 months of the date of issue. Project summary Project name Priest Residence, 9-15 Memphis St, Mount Druitt Street address 9-15 Memphis Street Mount Druitt 2770 Local Government Area Blacktown City Council Plan type and plan number deposited 1128 Lot no. 17-20 Section no. 4 Project type unit No. of bedrooms 1 Project score Water 40 Target 40 Thermal Comfort Pass Target Pass Energy 52 Target 50 Certificate Prepared by Name / Company Name: Building & Energy Consultants Australia ABN (if applicable): 92122407783 BASIX Planning & Environment www.basix.nsw.gov.au Version: 3.0 / DARWINIA_3_4_1 Certificate No.: 840979S Friday, 11 August 2017 page 1/7

Home - Blacktown City - Single Dwelling...Building Sustainability Index Single Dwelling Certificate number: 840979S This certificate confirms that the proposed development will meet

  • Upload
    others

  • View
    2

  • Download
    0

Embed Size (px)

Citation preview

Page 1: Home - Blacktown City - Single Dwelling...Building Sustainability Index Single Dwelling Certificate number: 840979S This certificate confirms that the proposed development will meet

Building Sustainability Index www.basix.nsw.gov.au

Single Dwelling

Certificate number: 840979S

This certificate confirms that the proposed development will meet the NSWgovernment's requirements for sustainability, if it is built in accordance with thecommitments set out below. Terms used in this certificate, or in the commitments,have the meaning given by the document entitled "BASIX Definitions" dated29/06/2009 published by the Department. This document is available atwww.basix.nsw.gov.au

SecretaryDate of issue: Friday, 11 August 2017To be valid, this certificate must be lodged within 3 months of the date of issue.

Project summaryProject name Priest Residence, 9-15 Memphis St, Mount

Druitt

Street address 9-15 Memphis Street Mount Druitt 2770

Local Government Area Blacktown City Council

Plan type and plan number deposited 1128

Lot no. 17-20

Section no. 4

Project type unit

No. of bedrooms 1

Project score

Water 40 Target 40

Thermal Comfort Pass Target Pass

Energy 52 Target 50

Certificate Prepared by

Name / Company Name: Building & Energy Consultants Australia

ABN (if applicable): 92122407783

BASIX Planning & Environment www.basix.nsw.gov.au Version: 3.0 / DARWINIA_3_4_1 Certificate No.: 840979S Friday, 11 August 2017 page 1/7

Page 2: Home - Blacktown City - Single Dwelling...Building Sustainability Index Single Dwelling Certificate number: 840979S This certificate confirms that the proposed development will meet

Description of project

Project addressProject name Priest Residence, 9-15 Memphis St, Mount

Druitt

Street address 9-15 Memphis Street Mount Druitt 2770

Local Government Area Blacktown City Council

Plan type and plan number Deposited Plan 1128

Lot no. 17-20

Section no. 4

Project typeProject type unit

No. of bedrooms 1

Site detailsSite area (m²) 3086

Roof area (m²) 813

Conditioned floor area (m2) 162.7

Unconditioned floor area (m2) 0.0

Total area of garden and lawn (m2) 50

Assessor details and thermal loadsAssessor number BDAV/12/1456

Certificate number 0001788389

Climate zone 28

Area adjusted cooling load (MJ/m².year) 55

Area adjusted heating load (MJ/m².year) 48

Project score

Water 40 Target 40

Thermal Comfort Pass Target Pass

Energy 52 Target 50

BASIX Planning & Environment www.basix.nsw.gov.au Version: 3.0 / DARWINIA_3_4_1 Certificate No.: 840979S Friday, 11 August 2017 page 2/7

Page 3: Home - Blacktown City - Single Dwelling...Building Sustainability Index Single Dwelling Certificate number: 840979S This certificate confirms that the proposed development will meet

Schedule of BASIX commitments

The commitments set out below regulate how the proposed development is to be carried out. It is a condition of any development consent granted, or complyingdevelopment certificate issued, for the proposed development, that BASIX commitments be complied with.

Water Commitments Show onDA plans

Show on CC/CDCplans & specs

Certifiercheck

Fixtures

The applicant must install showerheads with a minimum rating of 3 star (> 6 but <= 7.5 L/min) in all showers in the development.

The applicant must install a toilet flushing system with a minimum rating of 4 star in each toilet in the development.

The applicant must install taps with a minimum rating of 4 star in the kitchen in the development.

The applicant must install basin taps with a minimum rating of 5 star in each bathroom in the development.

Alternative water

Rainwater tank

The applicant must install a rainwater tank of at least 2400 litres on the site. This rainwater tank must meet, and be installed inaccordance with, the requirements of all applicable regulatory authorities.

The applicant must configure the rainwater tank to collect rain runoff from at least 150 square metres of the roof area of thedevelopment (excluding the area of the roof which drains to any stormwater tank or private dam).

The applicant must connect the rainwater tank to:

• all toilets in the development

• at least one outdoor tap in the development (Note: NSW Health does not recommend that rainwater be used for humanconsumption in areas with potable water supply.)

BASIX Planning & Environment www.basix.nsw.gov.au Version: 3.0 / DARWINIA_3_4_1 Certificate No.: 840979S Friday, 11 August 2017 page 3/7

Page 4: Home - Blacktown City - Single Dwelling...Building Sustainability Index Single Dwelling Certificate number: 840979S This certificate confirms that the proposed development will meet

Thermal Comfort Commitments Show onDA plans

Show on CC/CDCplans & specs

Certifiercheck

Simulation Method

The applicant must attach the certificate referred to under "Assessor Details" on the front page of this BASIX certificate (the "AssessorCertificate") to the development application and construction certificate application for the proposed development (or, if the applicant isapplying for a complying development certificate for the proposed development, to that application). The applicant must also attach theAssessor Certificate to the application for an occupation certificate for the proposed development.

The Assessor Certificate must have been issued by an Accredited Assessor in accordance with the Thermal Comfort Protocol.

The details of the proposed development on the Assessor Certificate must be consistent with the details shown in this BASIXcertificate, including the Cooling and Heating loads shown on the front page of this certificate.

The applicant must show on the plans accompanying the development application for the proposed development, all matters which theAssessor Certificate requires to be shown on those plans. Those plans must bear a stamp of endorsement from the AccreditedAssessor to certify that this is the case. The applicant must show on the plans accompanying the application for a constructioncertificate (or complying development certificate, if applicable), all thermal performance specifications set out in the AssessorCertificate, and all aspects of the proposed development which were used to calculate those specifications.

The applicant must construct the development in accordance with all thermal performance specifications set out in the AssessorCertificate, and in accordance with those aspects of the development application or application for a complying development certificatewhich were used to calculate those specifications.

The applicant must construct the floors and walls of the dwelling in accordance with the specifications listed in the table below.

Floor and wall construction Area

floor - concrete slab on ground All or part of floor area square metres

BASIX Planning & Environment www.basix.nsw.gov.au Version: 3.0 / DARWINIA_3_4_1 Certificate No.: 840979S Friday, 11 August 2017 page 4/7

Page 5: Home - Blacktown City - Single Dwelling...Building Sustainability Index Single Dwelling Certificate number: 840979S This certificate confirms that the proposed development will meet

Energy Commitments Show onDA plans

Show on CC/CDCplans & specs

Certifiercheck

Hot water

The applicant must install the following hot water system in the development, or a system with a higher energy rating: gasinstantaneous with a performance of 5 stars.

Cooling system

The applicant must install the following cooling system, or a system with a higher energy rating, in at least 1 living area: 1-phaseairconditioning; Energy rating: EER 2.5 - 3.0

The applicant must install the following cooling system, or a system with a higher energy rating, in at least 1 bedroom: 1-phaseairconditioning; Energy rating: EER 2.5 - 3.0

The cooling system must provide for day/night zoning between living areas and bedrooms.

Heating system

The applicant must install the following heating system, or a system with a higher energy rating, in at least 1 living area: 1-phaseairconditioning; Energy rating: EER 2.5 - 3.0

The applicant must install the following heating system, or a system with a higher energy rating, in at least 1 bedroom: 1-phaseairconditioning; Energy rating: EER 2.5 - 3.0

The heating system must provide for day/night zoning between living areas and bedrooms.

Ventilation

The applicant must install the following exhaust systems in the development:

At least 1 Bathroom: individual fan, ducted to façade or roof; Operation control: manual switch on/off

Kitchen: individual fan, ducted to façade or roof; Operation control: manual switch on/off

Laundry: individual fan, ducted to façade or roof; Operation control: manual switch on/off

Artificial lighting

The applicant must ensure that the "primary type of artificial lighting" is fluorescent or light emitting diode (LED) lighting in each of thefollowing rooms, and where the word "dedicated" appears, the fittings for those lights must only be capable of accepting fluorescent orlight emitting diode (LED) lamps:

• at least 1 of the bedrooms / study;

BASIX Planning & Environment www.basix.nsw.gov.au Version: 3.0 / DARWINIA_3_4_1 Certificate No.: 840979S Friday, 11 August 2017 page 5/7

Page 6: Home - Blacktown City - Single Dwelling...Building Sustainability Index Single Dwelling Certificate number: 840979S This certificate confirms that the proposed development will meet

Energy Commitments Show onDA plans

Show on CC/CDCplans & specs

Certifiercheck

• at least 1 of the living / dining rooms;

• the kitchen;

• all bathrooms/toilets;

• the laundry;

• all hallways;

Natural lighting

The applicant must install a window and/or skylight in the kitchen of the dwelling for natural lighting.

The applicant must install a window and/or skylight in 1 bathroom(s)/toilet(s) in the development for natural lighting.

Alternative energy

The applicant must install a photovoltaic system with the capacity to generate at least 1.2 peak kilowatts of electricity as part of thedevelopment. The applicant must connect this system to the development's electrical system.

Other

The applicant must install a gas cooktop & electric oven in the kitchen of the dwelling.

BASIX Planning & Environment www.basix.nsw.gov.au Version: 3.0 / DARWINIA_3_4_1 Certificate No.: 840979S Friday, 11 August 2017 page 6/7

Page 7: Home - Blacktown City - Single Dwelling...Building Sustainability Index Single Dwelling Certificate number: 840979S This certificate confirms that the proposed development will meet

Legend

In these commitments, "applicant" means the person carrying out the development.

Commitments identified with a in the "Show on DA plans" column must be shown on the plans accompanying the development application for the proposed development (if a

development application is to be lodged for the proposed development).

Commitments identified with a in the "Show on CC/CDC plans and specs" column must be shown in the plans and specifications accompanying the application for a construction

certificate / complying development certificate for the proposed development.

Commitments identified with a in the "Certifier check" column must be certified by a certifying authority as having been fulfilled, before a final occupation certificate(either interim or

final) for the development may be issued.

BASIX Planning & Environment www.basix.nsw.gov.au Version: 3.0 / DARWINIA_3_4_1 Certificate No.: 840979S Friday, 11 August 2017 page 7/7

Page 8: Home - Blacktown City - Single Dwelling...Building Sustainability Index Single Dwelling Certificate number: 840979S This certificate confirms that the proposed development will meet

NatHERS - THERMAL COMFORT SUMMARY

B.E.C.A (Building & Energy Consultants Australia Pty, Ltd). Shop 1, 18-30 Pindari Road, Peakhurst Heights NSW 2210 Tel: 9533 2388 [email protected] Fax: 9533 2588 Page 1 of 1

Address: Priest Residence, 9-15 Memphis Street Mount Druitt 2770 Date: 11/08/2017Software: BERS 4.3.0.2a Certificate Number: 0001788389 Star rating: 5.4Building Elements Material DetailExternal walls Brick veneer R2.0 Bulk insulationInternal walls Plasterboard on studsCommon walls between dwellings

BrickPlasterboard on studs

-

Ceiling Plasterboard R3.5 bulk insulation to ceilings with roof aboveFloors Concrete

Timber-

Roof Metal roof, Medium Colour Foil (sisalation) to underside of roof

Sliding windows & doorsAluminium Frame, single glazed clear

U Value 6.70 or less and SHGC 0.70 +/- 5%Windows

Glazed doorsAluminium Frame, single glazed clear

U Value 6.70 or less and SHGC 0.57 +/- 5%

Lighting: Dwellings have been rated with non-ventilated downlights – as per NatHERS certificateSelf-closing dampers to exhaust fansNote: Insulation specified must be installed in accordance with Part 3.12.1.1 of the BCA

Certificate no.:Assessor Name:Accreditation no.:Certificate date:

www.nathers.gov.au

Dwelling Address:

MJ/m2

0001788389Thomas RuckVIC/BDAV/12/14565.411 Aug 2017

102

Priest Residence, 9-15 Memphis StreetMount Druitt, NSW2770

Page 9: Home - Blacktown City - Single Dwelling...Building Sustainability Index Single Dwelling Certificate number: 840979S This certificate confirms that the proposed development will meet

* Nationwide House Energy Rating Scheme (NatHERS) is an initiative of the Australian, state and territory governments.For more details see www.nathers.gov.au

Nationwide House Energy Rating Scheme* Certificate Certificate number: Certificate Date: êStar rating:

MJ/m2

Assessor details

Accreditation number: Name: Organisation:Email: Phone: Declaration of interest:

Key construction and insulation materials (see following pages for details)

Construction:

Insulation:

Glazing:

Plan documents

Plan ref/date: Prepared by:

Net floor area (m2)

Conditioned: Unconditioned: Garage: TOTAL:

Annual thermal performance loads (MJ/m2)

Heating: Cooling: TOTAL:

Dwelling details

Street: Suburb: State:

Type:

Lot/DP number:

Postcode:NCC Class:NatHERSclimate zone:

Ceiling penetrations (see following pages for details)

Sealed: Unsealed: TOTAL:**

**NOTE: This total is themaximum number of ceilingpenetrations allowed to aceiling (under a roof) for thiscertificate. If this number isexceded in construction thenthis certificate IS NOT VALIDand a new certificate is required.Loss of ceiling insulation for thepenetrations listed has beentaken into account with the rating.

Principle downlight type:

Window selection - default windows only

Note on allowable window values:Only a 5% tolerance to the nominatedSHGC window values shown on page 2can be used with this rating.

Note: Only a +/- 5% SHGC tolerance is allowed with this rating.

NB: This tolerance ONLY applies to SHGC, the U-value can always be lower but not higher than the values stated on page 2.

If any of windows selected are outside the 5% tolerance then this certificate is no longer valid and the dwelling will need to be rerated to confirm compliance.

Overview

Scan to access this certificate online and confirm this is valid.

Software:

AAO:

Exposure:

11 Aug 20170001788389 5.4BERS Pro v4.3.0.0 (3.13) cannot be used to model 'roof windows'. Roof windows are 'openable or fixed windows in a roof' and do not have a shaft, as distinctfrom skylights which incorporate a built-in shaft and are not ventilated. BERS Pro v4.3 can only model skylights. If a roof window is present on the floor planthen this certificate is not valid.

5.4VIC/BDAV/12/1456Thomas RuckBuilding and Energy Consultants [email protected](02) 9533 2388None

BERS Pro v4.3.0.2a (3.13)

BDAV

102.0Unit Priest Residence, 9-15 Memphis StreetMount DruittNSW 2770New Dwelling 4

2817- 20/1128 Suburban

680

68Brick VeneerCorrugated IronTimber Floor, Unit BelowR2.0 wall insulationR3.5 ceiling insulationNo floor insulation

LED

ALM-002-01 A Aluminium B SG Clear

159.04.00.0

163.048.055.0

102.0

Job No: MDES033Monarch Projects

Page 1 of 6

Page 10: Home - Blacktown City - Single Dwelling...Building Sustainability Index Single Dwelling Certificate number: 840979S This certificate confirms that the proposed development will meet

Window type and performance valueWindow ID Window type U-value SHGCALM-002-01 A ALM-002-01 A Aluminium B SG Clear 6.7 0.70ALM-001-01 A ALM-001-01 A Aluminium A SG Clear 6.7 0.57

Window scheduleLocation Window ID Window no. Height (mm) Width (mm) Orientation Outdoor shadeKitchen/Living ALM-002-01 A n/a 900 1800 E No ShadingKitchen/Living ALM-001-01 A n/a 2400 1800 W No ShadingKitchen/Living ALM-002-01 A n/a 2400 850 W No ShadingKitchen/Living ALM-002-01 A n/a 2400 850 W No ShadingBedroom ALM-002-01 A n/a 1000 2400 W No ShadingEns ALM-002-01 A n/a 900 600 N No ShadingLiving ALM-002-01 A n/a 2100 3600 W No ShadingLiving ALM-002-01 A n/a 600 2400 E No ShadingStore room ALM-002-01 A n/a 1000 2400 E No ShadingStore room ALM-002-01 A n/a 1000 2400 W No Shading

Roof window and skylight type and performance valueID Window type U-value SHGCNone Present

Roof window and skylight scheduleLocation ID Roof

window/skylightno.

Area (m²) Orientation Outdoor shade Indoorshade/diffuser

None Present

External wall typeID Wall type Insulation Wall wrap or foilEW-1 Brick Veneer Bulk Insulation R2 No

External wall scheduleLocation ID Width (mm) Height (mm) Orientation Fixed Shade Eaves

(mm)Kitchen/Living EW-1 3095 3000 E No 100Kitchen/Living EW-1 4995 3000 W No 900Stairs EW-1 2100 3000 N No 100Stairs EW-1 4595 3000 E No 100Ldry EW-1 1700 3000 W No 0Ldry EW-1 600 3000 N No 5100Bedroom EW-1 4495 2500 N No 500Bedroom EW-1 2000 2500 S No 9100Bedroom EW-1 4500 2500 W No 500Ens EW-1 2090 2500 N No 500Living EW-1 5090 2500 W No 2500Living EW-1 5090 2500 E No 500

* Nationwide House Energy Rating Scheme (NatHERS) is an initiative of the Australian, state and territory governments. For more details see www.nathers.gov.au Page 2 of 6

Nationwide House Energy Rating Scheme* CertificateCertificate number: 0001788389 Certificate Date: 11 Aug 2017 ★ Star rating: 5.4

Building features

Page 11: Home - Blacktown City - Single Dwelling...Building Sustainability Index Single Dwelling Certificate number: 840979S This certificate confirms that the proposed development will meet

Stairs EW-1 2195 2500 N No 500Stairs EW-1 4495 2500 E No 500Store room EW-1 3995 2500 E No 500Store room EW-1 4000 2500 W No 2800Store room EW-1 2000 2500 N No 10100

Internal wall typeWall type Area (m²) Insulation Wall wrap or foilIW-1 - Stud, plasterboard 60.0 No Insulation NoIW-2 - Cavity wall, direct fixplasterboard, single gap

98.0 No insulation No

IW-3 - Cavity brick 45.0 No Insulation No

FloorsLocation Construction Area (m²) Sub floor

ventilationAddedinsulation

Covering

Kitchen/Living Concrete Slab on Ground200mm

36.9 None No Insulation 60/40 Carpet10mm/Ceramic

Stairs Concrete Slab on Ground200mm

9.6 None No Insulation Carpet 10mm

Ldry Concrete Slab on Ground200mm

4.3 None No Insulation Ceramic Tiles8mm

Study Concrete Slab on Ground200mm

11.4 None No Insulation Carpet 10mm

Bedroom Timber Floor, Unit Below 19mm 19.9 None No Insulation Carpet 10mmEns Timber Floor, Unit Below 19mm 4.7 None No Insulation Ceramic Tiles

8mmWC Timber Floor, Unit Below 19mm 4.0 None No Insulation Ceramic Tiles

8mmLiving/Kitchen/Living

Timber Above Plasterboard19mm

29.7 No Insulation Carpet 10mm

Living Timber Floor, Unit Below 19mm 4.2 None No Insulation Carpet 10mmStairs/Stairs Timber Above Plasterboard

19mm9.2 No Insulation Carpet 10mm

Store room/Study Timber Above Plasterboard19mm

3.9 No Insulation Carpet 10mm

Store room Timber Floor, Unit Below 19mm 12.9 None No Insulation Carpet 10mmStore room/Ldry Timber Above Plasterboard

19mm4.3 No Insulation Carpet 10mm

Store room/Study Timber Above Plasterboard19mm

7.5 No Insulation Carpet 10mm

Store room Timber Floor, Unit Below 19mm 5.9 None No Insulation Carpet 10mm

Ceiling typeLocation Construction Added

insulationRoof spaceabove

Kitchen/Living Plasterboard Bulk Insulation No

Nationwide House Energy Rating Scheme* CertificateCertificate number: 0001788389 Certificate Date: 11 Aug 2017 ★ Star rating: 5.4

Building features continued

* Nationwide House Energy Rating Scheme (NatHERS) is an initiative of the Australian, state and territory governments. For more details see www.nathers.gov.au Page 3 of 6

Page 12: Home - Blacktown City - Single Dwelling...Building Sustainability Index Single Dwelling Certificate number: 840979S This certificate confirms that the proposed development will meet

R3.5Kitchen/Living Timber Above Plasterboard No Insulation NoStairs Timber Above Plasterboard No Insulation NoLdry Timber Above Plasterboard No Insulation NoStudy Timber Above Plasterboard No Insulation NoBedroom Plasterboard Bulk Insulation

R3.5No

Ens Plasterboard Bulk InsulationR3.5

No

WC Plasterboard Bulk InsulationR3.5

No

Living Plasterboard Bulk InsulationR3.5

No

Stairs Plasterboard Bulk InsulationR3.5

No

Store room Plasterboard Bulk InsulationR3.5

No

Store room Plasterboard Bulk InsulationR3.5

No

Ceiling penetrationsLocation Number Type Diameter (mm) Sealed/unsealedKitchen/Living 14 Downlights - LED 150 SealedKitchen/Living 1 Exhaust Fans 300 SealedStairs 4 Downlights - LED 150 SealedLdry 2 Downlights - LED 150 SealedLdry 1 Exhaust Fans 300 SealedStudy 4 Downlights - LED 150 SealedBedroom 8 Downlights - LED 150 SealedEns 2 Downlights - LED 150 SealedEns 1 Exhaust Fans 300 SealedWC 2 Downlights - LED 150 SealedWC 1 Exhaust Fans 300 SealedLiving 14 Downlights - LED 150 SealedStairs 4 Downlights - LED 150 SealedStore room 5 Downlights - LED 150 SealedStore room 5 Downlights - LED 150 Sealed

Ceiling fansLocation Number Diameter (mm)None Present

Roof typeConstruction Added

insulationRoof colour

Nationwide House Energy Rating Scheme* CertificateCertificate number: 0001788389 Certificate Date: 11 Aug 2017 ★ Star rating: 5.4

Building features continued

* Nationwide House Energy Rating Scheme (NatHERS) is an initiative of the Australian, state and territory governments. For more details see www.nathers.gov.au Page 4 of 6

Page 13: Home - Blacktown City - Single Dwelling...Building Sustainability Index Single Dwelling Certificate number: 840979S This certificate confirms that the proposed development will meet

Waterproofing Membrane No AddedInsulation, No airGap

Medium

Corrugated Iron No Insulation,Only an Air Gap

Medium

Corrugated Iron Foil, Gap Above,Reflective SideDown, Anti-glareUp

Medium

Nationwide House Energy Rating Scheme* CertificateCertificate number: 0001788389 Certificate Date: 11 Aug 2017 ★ Star rating: 5.4

Building features continued

* Nationwide House Energy Rating Scheme (NatHERS) is an initiative of the Australian, state and territory governments. For more details see www.nathers.gov.au Page 5 of 6

Page 14: Home - Blacktown City - Single Dwelling...Building Sustainability Index Single Dwelling Certificate number: 840979S This certificate confirms that the proposed development will meet

* Nationwide House Energy Rating Scheme (NatHERS) is an initiative of the Australian, state and territory governments.

For more details see www.nathers.gov.au

Certificate Date:

Explanatory notes

Accredited Assessors

To ensure you get a high-quality, professional NatHERS House Energy Rating report, you should always use an

Organisation (AAO).

and continuing professional development requirements to maintain a high and consistent standard of assessments across the country. Non-accredited assessors do not have this level of quality assurance or any on-going training requirements.

concerns, please contact their AAO listed under ‘assessor

Disclaimer

The energy values quoted are for comparison purposes only; they are not a prediction of actual energy use. This rating

the rating.

Contact

For more information on the Nationwide House Energy Rating Scheme (NatHERS), visit www.nathers.gov.au

insulation visit www.yourhome.gov.au

About this report

including heating and cooling, hot water, dishwashers, ovens,

General Information

A NatHERS House Energy Rating is a comprehensive, dynamic computer modelling evaluation of the floorplans, elevations and specifications to predict an energy load of a home. Not all of us use our homes in the same way, so ratings are generated using standard assumptions. This means homes can be compared across the country.

The actual energy consumption of your home may vary significantly from the predicted energy load figures in the report depending on issues such as the size of your household and your personal preferences, e.g. in terms of heating or cooling.

While the figures are an indicative guide to energy use, they can be used as a reliable guide for comparative purposes between different house designs and for demonstrating that the design meets the required regulatory compliance.

Homes that are energy efficient use less energy, are warmer in winter, cooler in summer and cost less to run. The higher the star rating the more energy efficient.

This NatHERS House Energy Rating report was carefully prepared by your assessor on the basis of comprehensive modelling using standard procedures to rate your home using the underlying engine developed by the Australian Commonwealth Scientific and Industrial Research Organisation (CSIRO).

All information relating to energy loads presented in this report is based on a range of standard assumptions in order to allow for comparisons with reports prepared for other homes and to demonstrate minimum regulatory compliance.

The standard assumptions include figures for occupancy, indoor air temperature and are based on a unique climate file for your region.

Additional information

0001788389 11 Aug 2017 5.4

Page 6 of 6