9
JUNCTON BOX RECEPTACLE: 110 DUPLEX SWITCH RECEPTACLE: 110 DEDICATED DUPLEX THREE-WAY SWITCH RECEPTACLE: 110 QUAD MOTION (OCCUPANCY) SENSOR SWITCH RECEPTACLE: 208V OR 220V SWITCHBANK GROUNDING ELECTRODE CONNECTION TELEPHONE THERMOSTAT THERMOSTAT SENSOR PHOTOELECTRIC CELL DIMMER SWITCH SPEAKER L.A.N. RECEPTACLE RECEPTACLE: FLOOR DUPLEX RACEWAY TO PANEL OR BETWEEN OUTLETS-CONCEALED UNO. WIRE QUANTITIES NOT SHOWN. SEE POWER AND LIGHTING SHEETS FOR WIRING REQUIREMENTS. KEYED SWITCH GFI RECEPTACLE: 110 DUPLEX HARDWIRE CONNECTION TIME CLOCK DISCONNECT SWITCH, FUSED, IF NEEDED RECEPTACLE: CEILING DUPLEX 2401 UTAH AVENUE SOUTH SEATTLE, WASHINGTON 98134 (206) 318-1575 SHEET NUMBER: SHEET TITLE: SCALE: AS SHOWN STORE #: - PROJECT #: ISSUE DATE: DESIGN MANAGER: DRAWN BY: CHECKED BY: 08298-034 01/09/2017 HOUGHTON PLAZA 6733 108th Ave. NE Kirkland, WA 98033 PROJECT NAME: PROJECT ADDRESS: 3333 John Park Chris Rensch Revision Schedule Rev Date By Description STARBUCKS COFFEE COMPANY DESIGNER: C 2011 STARBUCKS COFFEE COMPANY R THESE DRAWINGS AND SPECIFICATIONS ARE CONFIDENTIAL AND SHALL REMAIN THE SOLE PROPERTY OF STARBUCKS CORPORATION, WHICH IS THE OWNER OF THE COPYRIGHT IN THIS WORK. THEY SHALL NOT BE REPRODUCED (IN WHOLE OR IN PART), SHARED WITH THIRD PARTIES OR USED IN ANY MANNER ON OTHER PROJECTS OR EXTENSIONS TO THIS PROJECT WITHOUT THE PRIOR WRITTEN CONSENT OF STARBUCKS CORPORATION. THESE DRAWINGS AND SPECIFICATIONS ARE INTENDED TO EXPRESS DESIGN INTENT FOR A PROTOTYPICAL STARBUCKS STORE (WHICH IS SUBJECT TO CHANGE AT ANYTIME) AND DO NOT REFLECT ACTUAL SITE CONDITIONS. NEITHER PARTY SHALL HAVE ANY OBLIGATION NOR LIABILITY TO THE OTHER (EXCEPT STATED ABOVE) UNTIL A WRITTEN AGREEMENT IS FULLY EXECUTED BY BOTH PARTIES. STARBUCKS TEMPLATE VERSION i2014.10.20 LLC 111 AVE. C SUITE 104, SNOHOMISH, WA 98290 PH: 360-863-6677 www.renschengineering.com FX: 360-863-3565 SECURITY SYSTEM NOTES CONFIRM EXISTING SYSTEM TYPE AND MODIFY/EXTEND AS NEEDED (NOT ALL SHOWN IN PLANS). CONFIRM SCOPE WITH STARBUCKS CM. STARBUCKS CONTRACTS DIRECTLY WITH SECURITY VENDOR TO SUPPLY AND INSTALL THE SECURITY SYSTEM. CONTRACTOR TO SCHEDULE INSTALLATION OF SECURITY SYSTEM FOR FOUR (4) TIMES; 1. MEET TO PLAN SECURITY CABLE PULL WITH SECURITY CABLE INSTALLER PRIOR TO DRYWALL INSTALLATION. 2. SECURITY CABLE INSTALLER PULLS SECURITY CABLES, MOUNTS PANEL, KEYPAD AND SENSORS. 3. SECURITY EQUIPMENT INSTALL OF CAMERA, NVR AND MONITOR. 4. SECURITY MONITORING COMPANY TO BRING SYSTEM ONLINE AND TRAIN PARTNERS AFTER POS INSTALL. SECURITY VENDOR REQUIRES A MINIMUM TWO (2) WEEKS LEAD TIME FOR EACH INSTALLATION. SECURITY VENDOR WILL COORDINATE REGIONAL INSTALLERS. ALL ADDITIONAL EXPENSES INCURRED DUE TO THE CONTRACTOR'S FAILURE TO SCHEDULE ACCORDINGLY WILL BE THE RESPONSIBILITY OF THE CONTRACTOR. TELEPHONE SYSTEM NOTES THE TELEPHONE SYSTEM IS EXISTING. MODIFY/EXTEND EXISTING SYSTEM AS NEEDED. (NOT ALL SHOWN IN PLANS) CONFIRM SCOPE WITH STARBUCKS CM. ALL TELEPHONE/NETWORK CABLING IS THE SCOPE OF WORK OF THE TELEPHONE/NETWORK CABLING VENDOR AND THE SECURITY SYSTEM VENDOR. TELEPHONE/NETWORK CABLING VENDOR SHALL BE SCHEDULED SUCH THAT CABLING IS COMPLETE PRIOR TO ARRIVAL OF SECURITY SYSTEM VENDOR. GENERAL CONTRACTOR SHALL SCHEDULE ON-SITE WORK PERFORMED BY THE TELEPHONE/NETWORK CABLING VENDOR AND THE SECURITY SYSTEM VENDOR. POS / DATA LINE NOTES CONFIRM EXISTING SYSTEM TYPE AND MODIFY/EXTEND AS NEEDED (NOT ALL SHOWN IN PLANS). CONFIRM SCOPE WITH STARBUCKS CM. STARBUCKS CONTRACTS DIRECTLY WITH THE DATA CABLING VENDOR TO SUPPLY AND INSTALL CATEGORY 5e (CAT5e) LAN CABLE AND CONNECTORS FOR THE POINT OF SALE (POS) SYSTEMS. CONTRACTOR TO SCHEDULE INSTALLATION OF DATA CABLING WITH DATA CABLING VENDOR. DATA CABLING VENDOR REQUIRES A LEAD TIME FOR INSTALLATION. DATA CABLING VENDOR WILL COORDINATE REGIONAL INSTALLERS. AT THE START OF CONSTRUCTION, STARBUCKS CONSTRUCTION MANAGER SCHEDULES DELIVER OF CASH REGISTER/MANAGER'S WORKSTATION EQUIPMENT AND INSTALLATION BY A POS INSTALL TECHNICIAN FOR ONE (1) MONTH PRIOR TO STORE OPEN. CONTRACTOR TO VERIFY DELIVERY SCHEDULE TWO (2) WEEKS PRIOR TO DELIVERY AND INSTALLATION DATE. EQUIPMENT IS SHIPPED DIRECTLY TO THE STORE. CONTRACTOR TO ACCEPT POS EQUIPMENT DELIVERY. DO NOT REFUSE DELIVERY. DATA CABLING TECHNICIAN TO PROVIDE ALL CAT5e LAN CABLING AND CONNECTORS FROM ALL DESIGNED AND FUTURE CASH REGISTER LOCATIONS, MANAGER'S WORKSTATION, ALL OTHER NETWORKED EQUIPMENT (CUP LABELERS, CLOVER, BUMP BAR, ETC...) AND WIRELESS ACCESS POINT TO THE DATA RACK AREA. CONTRACTOR IS TO HAVE CONDUIT WITH PULL STRING IN PLACE FOR ALL CABLE RUNS PRIOR TO CABLE INSTALL DATE. DATA CABLING TECHNICIAN TO PROVIDE ALL CATEGORY 5 LAN CABLING AND CONNECTIONS TO ALL DESIGNED AND FUTURE CASH REGISTER LOCATIONS AND MANAGER'S WORKSTATION. COMMUNICATION SYSTEM NOTES CONFIRM EXISTING SYSTEM TYPE AND MODIFY/EXTEND AS NEEDED (NOT ALL SHOWN IN PLANS). CONFIRM SCOPE WITH STARBUCKS CM. FIRE ALARM SYSTEM NOTES CONTRACTOR SHALL CONFIRM IF ANY ALARM SYSTEM DEVICES NEED TO BE ADDED OR RELOCATED. ALL DEVICE LOCATIONS SHALL BE APPROVED BY STARBUCKS DM PRIOR TO FINALIZING DESIGN. WIRELESS NETWORK NOTES SYSTEM IS EXISTING. MODIFY IF NEEDED. COORDINATE WITH STARBUCKS CM. MUSIC SYSTEM NOTES CONFIRM EXISTING SYSTEM TYPE AND MODIFY/EXTEND AS NEEDED (NOT ALL SHOWN IN PLANS). CONFIRM SCOPE WITH STARBUCKS CM. GENERAL ELECTRICAL NOTES 1. THE ELECTRICAL CONTRACTOR SHALL COORDINATE ELECTRICAL WORK AND SPECIFICATIONS WITH OTHER TRADES. THE ARCHITECTURAL DRAWINGS AND SPECIFICATIONS SHALL TAKE PRECEDENCE OVER ALL OTHER DRAWINGS. DO NOT SCALE DISTANCES OFF THE ELECTRICAL DRAWINGS; USE ACTUAL BUILDING DIMENSIONS. OVERALL CASEWORK COMPONENT DIMENSIONING ON ELECTRICAL DETAILS ARE SHOWN FOR REFERENCE AND COORDINATION ONLY. SEE SPECIFICATION SHEETS FOR ELECTRICAL SPECIFICATIONS. 2. ALL ELECTRICAL SYSTEMS SHALL BE TESTED FOR PROPER OPERATION. BALANCE ALL BRANCH CIRCUIT LOADS BETWEEN THE PHASES OF THE SYSTEM WITHIN 10% OF THE HIGHEST PHASE LOAD IN EACH PANEL BOARD. 3. THE ELECTRICAL CONTRACTOR SHALL BE RESPONSIBLE FOR DE-ENERGIZING CIRCUITS IN DEMOLITION AREAS TO INSURE A SAFE CONDITION. ELECTRICAL DEVICES AND ASSOCIATED WIRING LOCATED WITHIN THE DEMOLITION AREA THAT WILL NO LONGER BE USED SHALL BE REMOVED AND PROPERLY DISPOSED OF AT CONTRACTORS EXPENSE UNLESS OTHERWISE NOTED. 4. THE ELECTRICAL CONTRACTOR SHALL SCHEDULE ALL ELECTRICAL SYSTEM OUTAGES WITH THE GENERAL CONTRACTOR AND LANDLORD AT LEAST 24 HOURS IN ADVANCE. UNLESS APPROVED OTHERWISE ALL OUTAGES SHALL OCCUR BETWEEN 11:00PM AND 5:00AM. 5. ELECTRICAL CONTRACTOR SHALL FURNISH AND INSTALL ALL NECESSARY CONDUIT AND J-BOXES TO SUPPORT A COMPLETE SECURITY, PHONE, POS AND DATA SYSTEMS. SEE MANAGER WORKSTATION AND BAR POINT OF SALE (POS) POWER/TELECOM/SECURITY DIAGRAM. COORDINATE ALL DEVICE LOCATIONS AND MOUNTING HEIGHTS WITH SECURITY VENDOR PRIOR TO ROUGH-IN. PROVIDE END-TO-END PULL STRINGS IN ALL CONDUITS. LABEL EACH END OF THE PULL STRING WITH CONDUIT SYSTEM ("SECURITY") AND DESTINATION ("CAFÉ", "FRONT BAR", ETC.). PROVIDE INSULATED BUSHINGS ON ALL STUBBED-UP AND EXPOSED CONDUIT ENDS. 6. ELECTRICAL CONTRACTOR SHALL COORDINATE WITH THE GENERAL CONTRACTOR TO PATCH AND REPAIR ALL EXISTING WALLS, FLOORS, CEILINGS OR OTHER SURFACES IDENTIFIED TO REMAIN THAT MAY BECOME DAMAGED DURING THE COURSE OF WORK. 7. EXPOSED/SURFACE MOUNTED CONDUITS SHALL ONLY BE ALLOWED WHERE NECESSARY IN EXPOSED CEILING AREAS. IF CONDUITS NEED TO BE SURFACE MOUNTED TO WALLS, COORDINATE WITH STARBUCKS CONSTRUCTION MANAGER FOR APPROVAL. 8. VERIFY LOCATION OF ALL OUTLETS AND SWITCHES WITH ARCHITECTURAL DRAWINGS, INTERIOR DETAILS, FINISH SCHEDULES, GENERAL CONTRACTOR, EQUIPMENT VENDORS, STARBUCKS AND EXISTING SITE CONDITIONS. VERIFY FINAL DOOR HINGE LOCATION PRIOR TO SWITCH INSTALLATION AND ADJUST SWITCH LOCATION IF NEEDED. DO NOT MOUNT RECEPTACLES/SWITCHES IN LOCATIONS THAT WOULD CONFLICT WITH MIRRORS, SEAMS OF WALLS, WAINSCOTS, TILE TRANSITIONS, ETC. 9. UNLESS OTHERWISE NOTED (SEE ARCH. SHEETS), THE ELECTRICAL CONTRACTOR SHALL REMOVE ALL EXISTING ELECTRICAL EQUIPMENT INCLUDING WIRING, CONDUIT AND ALL OTHER MISC. DEVICES AS DIRECTED BY THE GENERAL CONTRACTOR THAT IS NOT BEING SALVAGED OR REUSED. EQUIPMENT INDICATED ON DRAWINGS TO BE REUSED SHALL BE INSPECTED AND IF DEFECTIVE, REPLACED. COORD. WITH GENERAL CONTRACTOR AND STARBUCKS. 10. COORDINATE WITH OTHER TRADES FOR ANY NEEDED LOW VOLTAGE CONTROL WIRING AND DEVICES THAT ARE NEEDED BUT MAY NOT BE SHOWN IN THESE DRAWINGS. 11. ELECTRICAL CONTRACTOR SHALL VERIFY THE LOCATION OF ALL EXISTING UTILITIES AND BE RESPONSIBLE FOR SITE INVESTIGATION PRIOR TO BID TO REVEAL THE FULL SCOPE OF WORK. IN ADDITION, THE ELECTRICAL CONTRACTOR SHALL THOROUGHLY EXAMINE ALL AREAS WHERE EQUIPMENT, CONDUIT AND WIRING WILL BE INSTALLED AND WILL REPORT ANY CONDITION THAT PREVENTS THE PROPER INSTALLATION OF THE ELECTRICAL WORK PRIOR TO BID. 12. DRAWINGS ARE DIAGRAMMATIC AND INDICATE GENERAL INTENT OR ARRANGEMENT OF SYSTEM(S). FOLLOW DRAWINGS IN LAYING OUT WORK AND COORD. WITH OTHER TRADES TO VERIFY SPACE CONDITIONS AND CLEARANCES. MAINTAIN HEADROOM AND SPACE CONDITION. MAKE APPROPRIATE ADJUSTMENTS AT STARBUCKS DIRECTION. 13. ALL IS NEW UNLESS OTHERWISE NOTED. GENERAL SPECIFICATION NOTES NOTE: "CONTRACTOR" MEANS "ELECTRICAL CONTRACTOR" WHEN REFERENCED ANYWHERE IN THE ELECTRICAL CONSTRUCTION DOCUMENTS UNLESS WORK AND EQUIPMENT HAS BEEN COORDINATED BETWEEN THE ELECTRICAL AND GENERAL CONTRACTORS TO BE PROVIDED BY THE GENERAL CONTRACTOR. "NEEDED", "PROVIDE" AND "INSTALL" MEANS ALL ITEMS CALLED OUT IN THE CONTRACT DOCUMENTS AND ANY ADDITIONAL ITEMS NOT CALLED OUT BUT REQUIRED TO MAKE A COMPLETE AND OPERATIONAL SYSTEM. SCOPE THE INTENT OF THE SPECIFICATION AND THE DRAWINGS IS TO PROVIDE A COMPLETE AND FULLY OPERATIONAL ELECTRICAL SYSTEM. THE ELECTRICAL CONTRACTOR SHALL FURNISH AND INSTALL ALL LABOR, MATERIAL AND EQUIPMENT NECESSARY TO COMPLETE THE ELECTRICAL WORK. SITE EXAMINATION THE ELECTRICAL CONTRACTOR SHALL THOROUGHLY EXAMINE ALL AREAS WHERE EQUIPMENT, CONDUIT, AND WIRING WILL BE INSTALLED AND WILL REPORT ANY CONDITION THAT, IN HIS OPINION, PREVENTS THE PROPER INSTALLATION OF THE ELECTRICAL WORK. STANDARDS EQUIPMENT AND MATERIALS SHALL CONFORM WITH APPROPRIATE PROVISIONS OF CSA, ULC, NEC, ASTM, UL, ETL, NEMA, ANSI, AS APPLICABLE, TO EACH INDIVIDUAL UNIT OR ASSEMBLY. CODES ALL WORK SHALL BE PERFORMED IN STRICT ACCORDANCE WITH ALL APPLICABLE PROVINCIAL AND LOCAL CODES AND ORDINANCES. IN CASE OF CONFLICT BETWEEN THE DRAWINGS AND SPECIFICATIONS AND THE CODES, THE HIGHEST STANDARD SHALL APPLY. ELECTRICAL CONTRACTOR SHALL SATISFY CODE REQUIREMENTS AS A MINIMUM STANDARD WITHOUT ANY EXTRA COST TO STARBUCKS. PERMITS AND FEES THE ELECTRICAL CONTRACTOR SHALL PROCURE AND PAY FOR ALL PERMITS, FEES AND INSPECTIONS NECESSARY TO COMPLETE THE ELECTRICAL WORK. WARRANTY THE ELECTRICAL CONTRACTOR SHALL UNCONDITIONALLY WARRANT ALL WORK TO BE FREE OF DEFECTS IN MATERIAL AND WORKMANSHIP FOR A PERIOD OF ONE (1) YEAR FROM THE DATE OF FINAL ACCEPTANCE BY STARBUCKS AND WILL REPAIR OR REPLACE ANY DEFECTIVE WORK PROMPTLY AND WITHOUT CHARGE AND RESTORE ANY OTHER EXISTING WORK DAMAGED IN THE COURSE OF REPAIRING DEFECTIVE MATERIALS AND WORKMANSHIP. CONTROLS AND OPERATION CONFIRM EXISTING SYSTEM TYPE AND MODIFY/EXTEND AS NEEDED (NOT ALL SHOWN IN PLANS). CONFIRM SCOPE WITH STARBUCKS CM. ELECTRICAL SYMBOL LEGEND ABBREVIATIONS AFF ABOVE FINISHED FLOOR AHJ AUTHORITIES HAVING JURISDICTION APPROX APPROXIMATE BLDG BUILDING CKT CIRCUIT CLG CEILING CM STARBUCKS CONSTRUCTION MANAGER CONST CONSTRUCTION CW COLD WATER CXA COMMISSIONING AGENT DEG DEGREES DL LIGHTS WITHIN DAYLIGHT ZONE DM STARBUCKS DESIGN MANAGER DN DOWN DTL DETAIL DWG(S) DRAWING(S) EA EACH EC ELECTRICAL CONTRACTOR ECP EQUIPMENT CONTROL PAC EG EXHAUST GRILLE ELEC ELECTRICAL EM EMERGENCY EMS ENERGY MANAGEMENT SYSTEM EXIST (E) OR (EX) EXISTING EXT EXTERIOR F&I FURNISH & INSTALL FLR FLOOR FT FOOT/FEET GC GENERAL CONTRACTOR GFCI GROUND FAULT CIRCUIT INTERRUPTER GND GROUND HR HOUR HVAC HEATING, VENTILATION, AIR CONDITIONING HW HOT WATER LCP LIGHTING CONTROL PANEL LL LANDLORD LS LIGHT SENSOR PHOTOCELL LV LOW VOLTAGE MAX MAXIMUM MC MECHANICAL CONTRACTOR MDP MAIN DISTRIBUTION PANEL MECH MECHANICAL MEP MECHANICAL, ELECTRICAL, AND PLUMBING MFG MANUFACTURER MIN MINIMUM NL NIGHTLIGHT NTS NOT TO SCALE OCP OVERCURRENT PROTECTION REF REFERENCE REQ(’D) REQUIRE(D) REV REVISION SF SQUARE FEET SHT SHEET SPECS SPECIFICATION(S) SS STAINLESS STEEL TEL TELEPHONE TEMP TEMPORARY TYP TYPICAL UNO UNLESS NOTED OTHERWISE VD VENDOR DIRECT WH WATER HEATER WP WEATHER PROOF NOTE: SOME SECTIONS INDICATED ON THIS SHEET AND SPECIFICATIONS MAY NOT APPLY TO THIS EXISTING STORE'S RENOVATION SCOPE. CONTRACTOR SHALL VERIFY RENOVATION SCOPE AND APPLY APPROPRIATE SPECIFICATION SECTION REQUIREMENTS. CONFIRM WITH CM. E-0001 Jasen D. Snyder Oliver Smith ELECTRICAL NOTES SHEET INDEX E-0001 ELECTRICAL NOTES E-0002 ELECTRICAL SPECIFICATIONS E-0003 ELECTRICAL ENERGY FORMS E-1100 ELECTRICAL UNDERSLAB PLAN E-1101 POWER PLAN E-1102 LIGHTING PLAN E-1103 ROOF POWER PLAN E-6001 ELECTRICAL SCHEDULES E-6002 ELECTRICAL PANELS & RISER L 1 of 2 LUTRON LIGHTING CONTROL GENERAL NOTES L 2 of 2 LUTRON LIGHTING CONTROL ONE-LINE DIAGRAM ESF17-00829 Page 1 of 9 MUST REMAIN ON JOBSITE City of Kirkland Reviewed by J Tumelson 02/27/2017

HOUGHTON PLAZA PROJECT ADDRESS - …permits.kirklandwa.gov/WebDocs/2017020848/3e1320db-59cb-492b-8bb9... · lcp lighting control panel ll landlord ls light sensor photocell lv low

Embed Size (px)

Citation preview

JUNCTON BOX RECEPTACLE:110 DUPLEX

SWITCH RECEPTACLE:110 DEDICATEDDUPLEX

THREE-WAY SWITCH RECEPTACLE:110 QUAD

MOTION (OCCUPANCY)SENSOR SWITCH

RECEPTACLE:208V OR 220V

SWITCHBANK

GROUNDINGELECTRODECONNECTION

TELEPHONE

THERMOSTAT

THERMOSTAT SENSOR PHOTOELECTRICCELL

DIMMER SWITCH

SPEAKER

L.A.N. RECEPTACLE

RECEPTACLE:FLOOR DUPLEX

RACEWAY TO PANEL OR BETWEENOUTLETS-CONCEALED UNO. WIREQUANTITIES NOT SHOWN. SEEPOWER AND LIGHTING SHEETS FORWIRING REQUIREMENTS.

KEYED SWITCH GFI RECEPTACLE:110 DUPLEX

HARDWIRECONNECTION

TIME CLOCK

DISCONNECTSWITCH, FUSED,IF NEEDED

RECEPTACLE:CEILING DUPLEX

2401 UTAH AVENUE SOUTHSEATTLE, WASHINGTON 98134

(206) 318-1575

SHEET NUMBER:

SHEET TITLE:

SCALE: AS SHOWN

STORE #:

-

PROJECT #:

ISSUE DATE:DESIGN MANAGER:

DRAWN BY:CHECKED BY:

08298-034

01/09/2017

HO

UG

HTO

N P

LAZA

6733

108

th A

ve. N

EK

irkla

nd, W

A 9

8033

PR

OJE

CT

NA

ME

:

PR

OJE

CT

AD

DR

ES

S:

3333

John Park

Chris Rensch

Revision ScheduleRev Date By Description

STARBUCKS COFFEECOMPANY

DESIGNER:

C 2011 STARBUCKS COFFEE COMPANY

R

THESE DRAWINGS AND SPECIFICATIONS ARECONFIDENTIAL AND SHALL REMAIN THE SOLEPROPERTY OF STARBUCKS CORPORATION,

WHICH IS THE OWNER OF THE COPYRIGHT INTHIS WORK. THEY SHALL NOT BE REPRODUCED

(IN WHOLE OR IN PART), SHARED WITH THIRDPARTIES OR USED IN ANY MANNER ON OTHERPROJECTS OR EXTENSIONS TO THIS PROJECTWITHOUT THE PRIOR WRITTEN CONSENT OF

STARBUCKS CORPORATION. THESE DRAWINGSAND SPECIFICATIONS ARE INTENDED TO

EXPRESS DESIGN INTENT FOR APROTOTYPICAL STARBUCKS STORE (WHICH IS

SUBJECT TO CHANGE AT ANYTIME) AND DO NOTREFLECT ACTUAL SITE CONDITIONS. NEITHER

PARTY SHALL HAVE ANY OBLIGATION NORLIABILITY TO THE OTHER (EXCEPT STATED

ABOVE) UNTIL A WRITTEN AGREEMENT IS FULLYEXECUTED BY BOTH PARTIES.

STARBUCKS TEMPLATE VERSION i2014.10.20

LLC

111 AVE. C SUITE 104, SNOHOMISH, WA 98290PH: 360-863-6677

www.renschengineering.comFX: 360-863-3565

SECURITY SYSTEM NOTESCONFIRM EXISTING SYSTEM TYPE AND MODIFY/EXTEND AS NEEDED(NOT ALL SHOWN IN PLANS). CONFIRM SCOPE WITH STARBUCKS CM.

STARBUCKS CONTRACTS DIRECTLY WITH SECURITY VENDOR TOSUPPLY AND INSTALL THE SECURITY SYSTEM. CONTRACTOR TOSCHEDULE INSTALLATION OF SECURITY SYSTEM FOR FOUR (4)TIMES;

1. MEET TO PLAN SECURITY CABLE PULL WITH SECURITY CABLEINSTALLER PRIOR TO DRYWALL INSTALLATION.

2. SECURITY CABLE INSTALLER PULLS SECURITY CABLES, MOUNTSPANEL, KEYPAD AND SENSORS.

3. SECURITY EQUIPMENT INSTALL OF CAMERA, NVR AND MONITOR.4. SECURITY MONITORING COMPANY TO BRING SYSTEM ONLINE

AND TRAIN PARTNERS AFTER POS INSTALL.

SECURITY VENDOR REQUIRES A MINIMUM TWO (2) WEEKS LEAD TIMEFOR EACH INSTALLATION. SECURITY VENDOR WILL COORDINATEREGIONAL INSTALLERS. ALL ADDITIONAL EXPENSES INCURRED DUETO THE CONTRACTOR'S FAILURE TO SCHEDULE ACCORDINGLY WILLBE THE RESPONSIBILITY OF THE CONTRACTOR.

TELEPHONE SYSTEM NOTESTHE TELEPHONE SYSTEM IS EXISTING. MODIFY/EXTEND EXISTINGSYSTEM AS NEEDED. (NOT ALL SHOWN IN PLANS) CONFIRM SCOPEWITH STARBUCKS CM.

ALL TELEPHONE/NETWORK CABLING IS THE SCOPE OF WORK OF THETELEPHONE/NETWORK CABLING VENDOR AND THE SECURITYSYSTEM VENDOR. TELEPHONE/NETWORK CABLING VENDOR SHALLBE SCHEDULED SUCH THAT CABLING IS COMPLETE PRIOR TOARRIVAL OF SECURITY SYSTEM VENDOR.

GENERAL CONTRACTOR SHALL SCHEDULE ON-SITE WORKPERFORMED BY THE TELEPHONE/NETWORK CABLING VENDOR ANDTHE SECURITY SYSTEM VENDOR.

POS / DATA LINE NOTESCONFIRM EXISTING SYSTEM TYPE AND MODIFY/EXTEND AS NEEDED(NOT ALL SHOWN IN PLANS). CONFIRM SCOPE WITH STARBUCKS CM.

STARBUCKS CONTRACTS DIRECTLY WITH THE DATA CABLINGVENDOR TO SUPPLY AND INSTALL CATEGORY 5e (CAT5e) LAN CABLEAND CONNECTORS FOR THE POINT OF SALE (POS) SYSTEMS.CONTRACTOR TO SCHEDULE INSTALLATION OF DATA CABLING WITHDATA CABLING VENDOR. DATA CABLING VENDOR REQUIRES A LEADTIME FOR INSTALLATION. DATA CABLING VENDOR WILL COORDINATEREGIONAL INSTALLERS.

AT THE START OF CONSTRUCTION, STARBUCKS CONSTRUCTIONMANAGER SCHEDULES DELIVER OF CASH REGISTER/MANAGER'SWORKSTATION EQUIPMENT AND INSTALLATION BY A POS INSTALLTECHNICIAN FOR ONE (1) MONTH PRIOR TO STORE OPEN.CONTRACTOR TO VERIFY DELIVERY SCHEDULE TWO (2) WEEKSPRIOR TO DELIVERY AND INSTALLATION DATE. EQUIPMENT ISSHIPPED DIRECTLY TO THE STORE. CONTRACTOR TO ACCEPT POSEQUIPMENT DELIVERY. DO NOT REFUSE DELIVERY.

DATA CABLING TECHNICIAN TO PROVIDE ALL CAT5e LAN CABLINGAND CONNECTORS FROM ALL DESIGNED AND FUTURE CASHREGISTER LOCATIONS, MANAGER'S WORKSTATION, ALL OTHERNETWORKED EQUIPMENT (CUP LABELERS, CLOVER, BUMP BAR,ETC...) AND WIRELESS ACCESS POINT TO THE DATA RACK AREA.CONTRACTOR IS TO HAVE CONDUIT WITH PULL STRING IN PLACE FORALL CABLE RUNS PRIOR TO CABLE INSTALL DATE.

DATA CABLING TECHNICIAN TO PROVIDE ALL CATEGORY 5 LANCABLING AND CONNECTIONS TO ALL DESIGNED AND FUTURE CASHREGISTER LOCATIONS AND MANAGER'S WORKSTATION.

COMMUNICATION SYSTEM NOTESCONFIRM EXISTING SYSTEM TYPE AND MODIFY/EXTEND AS NEEDED(NOT ALL SHOWN IN PLANS). CONFIRM SCOPE WITH STARBUCKS CM.

FIRE ALARM SYSTEM NOTESCONTRACTOR SHALL CONFIRM IF ANY ALARM SYSTEM DEVICESNEED TO BE ADDED OR RELOCATED. ALL DEVICE LOCATIONS SHALLBE APPROVED BY STARBUCKS DM PRIOR TO FINALIZING DESIGN.

WIRELESS NETWORK NOTESSYSTEM IS EXISTING. MODIFY IF NEEDED. COORDINATE WITHSTARBUCKS CM.

MUSIC SYSTEM NOTESCONFIRM EXISTING SYSTEM TYPE AND MODIFY/EXTEND AS NEEDED(NOT ALL SHOWN IN PLANS). CONFIRM SCOPE WITH STARBUCKS CM.

GENERAL ELECTRICAL NOTES1. THE ELECTRICAL CONTRACTOR SHALL COORDINATE

ELECTRICAL WORK AND SPECIFICATIONS WITH OTHER TRADES.THE ARCHITECTURAL DRAWINGS AND SPECIFICATIONS SHALLTAKE PRECEDENCE OVER ALL OTHER DRAWINGS. DO NOTSCALE DISTANCES OFF THE ELECTRICAL DRAWINGS; USEACTUAL BUILDING DIMENSIONS. OVERALL CASEWORKCOMPONENT DIMENSIONING ON ELECTRICAL DETAILS ARESHOWN FOR REFERENCE AND COORDINATION ONLY. SEESPECIFICATION SHEETS FOR ELECTRICAL SPECIFICATIONS.

2. ALL ELECTRICAL SYSTEMS SHALL BE TESTED FOR PROPEROPERATION. BALANCE ALL BRANCH CIRCUIT LOADS BETWEENTHE PHASES OF THE SYSTEM WITHIN 10% OF THE HIGHESTPHASE LOAD IN EACH PANEL BOARD.

3. THE ELECTRICAL CONTRACTOR SHALL BE RESPONSIBLE FORDE-ENERGIZING CIRCUITS IN DEMOLITION AREAS TO INSURE ASAFE CONDITION. ELECTRICAL DEVICES AND ASSOCIATEDWIRING LOCATED WITHIN THE DEMOLITION AREA THAT WILL NOLONGER BE USED SHALL BE REMOVED AND PROPERLYDISPOSED OF AT CONTRACTORS EXPENSE UNLESSOTHERWISE NOTED.

4. THE ELECTRICAL CONTRACTOR SHALL SCHEDULE ALLELECTRICAL SYSTEM OUTAGES WITH THE GENERALCONTRACTOR AND LANDLORD AT LEAST 24 HOURS INADVANCE. UNLESS APPROVED OTHERWISE ALL OUTAGESSHALL OCCUR BETWEEN 11:00PM AND 5:00AM.

5. ELECTRICAL CONTRACTOR SHALL FURNISH AND INSTALL ALLNECESSARY CONDUIT AND J-BOXES TO SUPPORT A COMPLETESECURITY, PHONE, POS AND DATA SYSTEMS. SEE MANAGERWORKSTATION AND BAR POINT OF SALE (POS)POWER/TELECOM/SECURITY DIAGRAM. COORDINATE ALLDEVICE LOCATIONS AND MOUNTING HEIGHTS WITH SECURITYVENDOR PRIOR TO ROUGH-IN. PROVIDE END-TO-END PULLSTRINGS IN ALL CONDUITS. LABEL EACH END OF THE PULLSTRING WITH CONDUIT SYSTEM ("SECURITY") ANDDESTINATION ("CAFÉ", "FRONT BAR", ETC.). PROVIDEINSULATED BUSHINGS ON ALL STUBBED-UP AND EXPOSEDCONDUIT ENDS.

6. ELECTRICAL CONTRACTOR SHALL COORDINATE WITH THEGENERAL CONTRACTOR TO PATCH AND REPAIR ALL EXISTINGWALLS, FLOORS, CEILINGS OR OTHER SURFACES IDENTIFIEDTO REMAIN THAT MAY BECOME DAMAGED DURING THECOURSE OF WORK.

7. EXPOSED/SURFACE MOUNTED CONDUITS SHALL ONLY BEALLOWED WHERE NECESSARY IN EXPOSED CEILING AREAS. IFCONDUITS NEED TO BE SURFACE MOUNTED TO WALLS,COORDINATE WITH STARBUCKS CONSTRUCTION MANAGERFOR APPROVAL.

8. VERIFY LOCATION OF ALL OUTLETS AND SWITCHES WITHARCHITECTURAL DRAWINGS, INTERIOR DETAILS, FINISHSCHEDULES, GENERAL CONTRACTOR, EQUIPMENT VENDORS,STARBUCKS AND EXISTING SITE CONDITIONS. VERIFY FINALDOOR HINGE LOCATION PRIOR TO SWITCH INSTALLATION ANDADJUST SWITCH LOCATION IF NEEDED. DO NOT MOUNTRECEPTACLES/SWITCHES IN LOCATIONS THAT WOULDCONFLICT WITH MIRRORS, SEAMS OF WALLS, WAINSCOTS, TILETRANSITIONS, ETC.

9. UNLESS OTHERWISE NOTED (SEE ARCH. SHEETS), THEELECTRICAL CONTRACTOR SHALL REMOVE ALL EXISTINGELECTRICAL EQUIPMENT INCLUDING WIRING, CONDUIT AND ALLOTHER MISC. DEVICES AS DIRECTED BY THE GENERALCONTRACTOR THAT IS NOT BEING SALVAGED OR REUSED.EQUIPMENT INDICATED ON DRAWINGS TO BE REUSED SHALLBE INSPECTED AND IF DEFECTIVE, REPLACED. COORD. WITHGENERAL CONTRACTOR AND STARBUCKS.

10. COORDINATE WITH OTHER TRADES FOR ANY NEEDED LOWVOLTAGE CONTROL WIRING AND DEVICES THAT ARE NEEDEDBUT MAY NOT BE SHOWN IN THESE DRAWINGS.

11. ELECTRICAL CONTRACTOR SHALL VERIFY THE LOCATION OFALL EXISTING UTILITIES AND BE RESPONSIBLE FOR SITEINVESTIGATION PRIOR TO BID TO REVEAL THE FULL SCOPE OFWORK. IN ADDITION, THE ELECTRICAL CONTRACTOR SHALLTHOROUGHLY EXAMINE ALL AREAS WHERE EQUIPMENT,CONDUIT AND WIRING WILL BE INSTALLED AND WILL REPORTANY CONDITION THAT PREVENTS THE PROPER INSTALLATIONOF THE ELECTRICAL WORK PRIOR TO BID.

12. DRAWINGS ARE DIAGRAMMATIC AND INDICATE GENERALINTENT OR ARRANGEMENT OF SYSTEM(S). FOLLOW DRAWINGSIN LAYING OUT WORK AND COORD. WITH OTHER TRADES TOVERIFY SPACE CONDITIONS AND CLEARANCES. MAINTAINHEADROOM AND SPACE CONDITION. MAKE APPROPRIATEADJUSTMENTS AT STARBUCKS DIRECTION.

13. ALL IS NEW UNLESS OTHERWISE NOTED.

GENERAL SPECIFICATION NOTESNOTE: "CONTRACTOR" MEANS "ELECTRICAL CONTRACTOR" WHENREFERENCED ANYWHERE IN THE ELECTRICAL CONSTRUCTIONDOCUMENTS UNLESS WORK AND EQUIPMENT HAS BEENCOORDINATED BETWEEN THE ELECTRICAL AND GENERALCONTRACTORS TO BE PROVIDED BY THE GENERAL CONTRACTOR."NEEDED", "PROVIDE" AND "INSTALL" MEANS ALL ITEMS CALLED OUTIN THE CONTRACT DOCUMENTS AND ANY ADDITIONAL ITEMS NOTCALLED OUT BUT REQUIRED TO MAKE A COMPLETE ANDOPERATIONAL SYSTEM.

SCOPETHE INTENT OF THE SPECIFICATION AND THE DRAWINGS IS TOPROVIDE A COMPLETE AND FULLY OPERATIONAL ELECTRICALSYSTEM. THE ELECTRICAL CONTRACTOR SHALL FURNISH ANDINSTALL ALL LABOR, MATERIAL AND EQUIPMENT NECESSARY TOCOMPLETE THE ELECTRICAL WORK.

SITE EXAMINATIONTHE ELECTRICAL CONTRACTOR SHALL THOROUGHLY EXAMINE ALLAREAS WHERE EQUIPMENT, CONDUIT, AND WIRING WILL BEINSTALLED AND WILL REPORT ANY CONDITION THAT, IN HIS OPINION,PREVENTS THE PROPER INSTALLATION OF THE ELECTRICAL WORK.

STANDARDSEQUIPMENT AND MATERIALS SHALL CONFORM WITH APPROPRIATEPROVISIONS OF CSA, ULC, NEC, ASTM, UL, ETL, NEMA, ANSI, ASAPPLICABLE, TO EACH INDIVIDUAL UNIT OR ASSEMBLY.

CODESALL WORK SHALL BE PERFORMED IN STRICT ACCORDANCE WITH ALLAPPLICABLE PROVINCIAL AND LOCAL CODES AND ORDINANCES. INCASE OF CONFLICT BETWEEN THE DRAWINGS AND SPECIFICATIONSAND THE CODES, THE HIGHEST STANDARD SHALL APPLY.ELECTRICAL CONTRACTOR SHALL SATISFY CODE REQUIREMENTS ASA MINIMUM STANDARD WITHOUT ANY EXTRA COST TO STARBUCKS.

PERMITS AND FEESTHE ELECTRICAL CONTRACTOR SHALL PROCURE AND PAY FOR ALLPERMITS, FEES AND INSPECTIONS NECESSARY TO COMPLETE THEELECTRICAL WORK.

WARRANTYTHE ELECTRICAL CONTRACTOR SHALL UNCONDITIONALLY WARRANTALL WORK TO BE FREE OF DEFECTS IN MATERIAL ANDWORKMANSHIP FOR A PERIOD OF ONE (1) YEAR FROM THE DATE OFFINAL ACCEPTANCE BY STARBUCKS AND WILL REPAIR OR REPLACEANY DEFECTIVE WORK PROMPTLY AND WITHOUT CHARGE ANDRESTORE ANY OTHER EXISTING WORK DAMAGED IN THE COURSE OFREPAIRING DEFECTIVE MATERIALS AND WORKMANSHIP.

CONTROLS AND OPERATIONCONFIRM EXISTING SYSTEM TYPE AND MODIFY/EXTEND AS NEEDED(NOT ALL SHOWN IN PLANS). CONFIRM SCOPE WITH STARBUCKS CM.

ELECTRICAL SYMBOL LEGENDABBREVIATIONSAFF ABOVE FINISHED FLOORAHJ AUTHORITIES HAVING JURISDICTIONAPPROX APPROXIMATE

BLDG BUILDING

CKT CIRCUITCLG CEILINGCM STARBUCKS CONSTRUCTION MANAGERCONST CONSTRUCTIONCW COLD WATERCXA COMMISSIONING AGENT

DEG DEGREESDL LIGHTS WITHIN DAYLIGHT ZONEDM STARBUCKS DESIGN MANAGERDN DOWNDTL DETAILDWG(S) DRAWING(S)

EA EACHEC ELECTRICAL CONTRACTORECP EQUIPMENT CONTROL PACEG EXHAUST GRILLEELEC ELECTRICALEM EMERGENCYEMS ENERGY MANAGEMENT SYSTEMEXIST (E) OR (EX) EXISTINGEXT EXTERIOR

F&I FURNISH & INSTALLFLR FLOORFT FOOT/FEET

GC GENERAL CONTRACTORGFCI GROUND FAULT CIRCUIT INTERRUPTERGND GROUND

HR HOURHVAC HEATING, VENTILATION, AIR CONDITIONINGHW HOT WATER

LCP LIGHTING CONTROL PANELLL LANDLORDLS LIGHT SENSOR PHOTOCELLLV LOW VOLTAGE

MAX MAXIMUMMC MECHANICAL CONTRACTORMDP MAIN DISTRIBUTION PANELMECH MECHANICALMEP MECHANICAL, ELECTRICAL, AND PLUMBINGMFG MANUFACTURERMIN MINIMUM

NL NIGHTLIGHTNTS NOT TO SCALE

OCP OVERCURRENT PROTECTION

REF REFERENCEREQ(’D) REQUIRE(D)REV REVISION

SF SQUARE FEETSHT SHEETSPECS SPECIFICATION(S)SS STAINLESS STEEL

TEL TELEPHONETEMP TEMPORARYTYP TYPICAL

UNO UNLESS NOTED OTHERWISE

VD VENDOR DIRECT

WH WATER HEATERWP WEATHER PROOF

NOTE: SOME SECTIONS INDICATED ON THISSHEET AND SPECIFICATIONS MAY NOT APPLY

TO THIS EXISTING STORE'S RENOVATIONSCOPE. CONTRACTOR SHALL VERIFY

RENOVATION SCOPE AND APPLYAPPROPRIATE SPECIFICATION SECTION

REQUIREMENTS. CONFIRM WITH CM.

E-0001

Jasen D. SnyderOliver Smith

ELECTRICAL NOTES

SHEET INDEXE-0001 ELECTRICAL NOTESE-0002 ELECTRICAL SPECIFICATIONSE-0003 ELECTRICAL ENERGY FORMSE-1100 ELECTRICAL UNDERSLAB PLANE-1101 POWER PLANE-1102 LIGHTING PLANE-1103 ROOF POWER PLANE-6001 ELECTRICAL SCHEDULESE-6002 ELECTRICAL PANELS & RISER

L 1 of 2 LUTRON LIGHTING CONTROL GENERAL NOTESL 2 of 2 LUTRON LIGHTING CONTROL ONE-LINE DIAGRAM

ESF17-00829Page 1 of 9

MUST REMAIN ON JOBSITE

City of KirklandReviewed by J Tumelson02/27/2017

2401 UTAH AVENUE SOUTHSEATTLE, WASHINGTON 98134

(206) 318-1575

SHEET NUMBER:

SHEET TITLE:

SCALE: AS SHOWN

STORE #:

-

PROJECT #:

ISSUE DATE:DESIGN MANAGER:

DRAWN BY:CHECKED BY:

08298-034

01/09/2017

HO

UG

HTO

N P

LAZA

6733

108

th A

ve. N

EK

irkla

nd, W

A 9

8033

PR

OJE

CT

NA

ME

:

PR

OJE

CT

AD

DR

ES

S:

3333

John Park

Chris Rensch

Revision ScheduleRev Date By Description

STARBUCKS COFFEECOMPANY

DESIGNER:

C 2011 STARBUCKS COFFEE COMPANY

R

THESE DRAWINGS AND SPECIFICATIONS ARECONFIDENTIAL AND SHALL REMAIN THE SOLEPROPERTY OF STARBUCKS CORPORATION,

WHICH IS THE OWNER OF THE COPYRIGHT INTHIS WORK. THEY SHALL NOT BE REPRODUCED

(IN WHOLE OR IN PART), SHARED WITH THIRDPARTIES OR USED IN ANY MANNER ON OTHERPROJECTS OR EXTENSIONS TO THIS PROJECTWITHOUT THE PRIOR WRITTEN CONSENT OF

STARBUCKS CORPORATION. THESE DRAWINGSAND SPECIFICATIONS ARE INTENDED TO

EXPRESS DESIGN INTENT FOR APROTOTYPICAL STARBUCKS STORE (WHICH IS

SUBJECT TO CHANGE AT ANYTIME) AND DO NOTREFLECT ACTUAL SITE CONDITIONS. NEITHER

PARTY SHALL HAVE ANY OBLIGATION NORLIABILITY TO THE OTHER (EXCEPT STATED

ABOVE) UNTIL A WRITTEN AGREEMENT IS FULLYEXECUTED BY BOTH PARTIES.

STARBUCKS TEMPLATE VERSION i2014.10.20

LLC

111 AVE. C SUITE 104, SNOHOMISH, WA 98290PH: 360-863-6677

www.renschengineering.comFX: 360-863-3565

E-0002

Yumi RothDrafter

ELECTRICALSPECIFICATIONS

ELECTRICALSECTION 260519 - LOW-VOLTAGE (600V OR LESS) ELECTRICALPOWER CONDUCTORS AND CABLES

1.1 MATERIALSA. CONDUCTORS AND CABLES:

1. CONDUCTORS: COPPER.2. CONDUCTOR INSULATION: TYPE THHN/THWN-2,

TYPE XHHW-2, TYPE USE AND TYPE SO.3. MULTI-CONDUCTOR CABLE: METAL-CLAD CABLE, TYPE MC

WITH GROUND WIRE.

1.2 CONDUCTOR MATERIAL APPLICATIONSA. FEEDERS: COPPER. SOLID FOR NO. 10 AWG AND SMALLER;

STRANDED FOR NO. 8 AWG AND LARGER.B. BRANCH CIRCUITS: COPPER. SOLID FOR NO. 10 AWG AND

SMALLER; STRANDED FOR NO. 8 AWG AND LARGER, EXCEPTVFC CABLE, WHICH SHALL BE EXTRA FLEXIBLE STRANDED.

1.3 CONDUCTOR INSULATION AND MULTI-CONDUCTOR CABLEAPPLICATIONS AND WIRING METHODSA. SERVICE ENTRANCE: TYPE THHN/THWN-2, SINGLE

CONDUCTORS IN RACEWAY.B. EXPOSED FEEDERS: TYPE THHN/THWN-2, SINGLE

CONDUCTORS IN RACEWAY.C. FEEDERS CONCEALED IN CEILINGS, WALLS, PARTITIONS, AND

CRAWLSPACES: TYPE THHN/THWN-2, SINGLE CONDUCTORS INRACEWAY.

D. FEEDERS CONCEALED IN CONCRETE, BELOWSLABS-ON-GRADE AND UNDERGROUND: TYPE THHN/THWN-2,SINGLE CONDUCTORS IN RACEWAY.

E. EXPOSED BRANCH CIRCUITS, INCLUDING IN CRAWLSPACES:TYPE THHN/THWN-2, SINGLE CONDUCTORS IN RACEWAY.

F. BRANCH CIRCUITS CONCEALED IN CEILINGS, WALLS ANDPARTITIONS: TYPE THHN/THWN-2, SINGLE CONDUCTORS INRACEWAY AND MC CABLE.

G. BRANCH CIRCUITS CONCEALED IN CONCRETE, BELOWSLABS-ON-GRADE AND UNDERGROUND: TYPE THHN/THWN-2,SINGLE CONDUCTORS IN RACEWAY.

H. CORD DROPS AND PORTABLE APPLIANCE CONNECTIONS:TYPE SO, HARD SERVICE CORD WITH STAINLESS-STEEL,WIRE-MESH, STRAIN RELIEF DEVICE AT TERMINATIONS TOSUIT APPLICATION.

1.4 FIELD QUALITY CONTROLA. TESTING: BY CONTRACTOR.

END OF SECTION 260519

SECTION 260526 - GROUNDING AND BONDING FOR ELECTRICALSYSTEMS

1.1 QUALITY ASSURANCEA. QUALITY STANDARD FOR GROUNDING AND BONDING

MATERIALS AND EQUIPMENT: UL 467.

1.2 PRODUCTSA. INSULATED CONDUCTORS: COPPER WIRE OR CABLE.B. BARE COPPER CONDUCTORS:

1. SOLID CONDUCTORS.2. STRANDED CONDUCTORS.3. TINNED CONDUCTORS.4. STRANDED BONDING CONDUCTORS.5. COPPER TAPE BRAIDED BONDING JUMPERS.6. TINNED-COPPER BRAIDED BONDING JUMPERS.

C. CONNECTORS: BOLTED AND EXOTHERMIC-WELDED TYPE.D. GROUNDING ELECTRODES:

1. GROUND RODS: COPPER-CLAD STEEL, SECTIONAL TYPEWITH GROUND WELL AND COVER.

1.3 FIELD QUALITY CONTROLA. GROUND RESISTANCE TESTING: BY CONTRACTOR-ENGAGED

AGENCY.

END OF SECTION 260526

SECTION 260529 - HANGERS AND SUPPORTS FOR ELECTRICALSYSTEMS

1.1 PERFORMANCE REQUIREMENTSA. DESIGN SUPPORTS FOR MULTIPLE RACEWAYS CAPABLE OF

SUPPORTING COMBINED WEIGHT OF SUPPORTED SYSTEMSAND ITS CONTENTS.

B. DESIGN EQUIPMENT SUPPORTS CAPABLE OF SUPPORTINGCOMBINED OPERATING WEIGHT OF SUPPORTED EQUIPMENT,CONNECTED SYSTEMS AND COMPONENTS.

1.2 PRODUCTSA. SUPPORT, ANCHORAGE AND ATTACHMENT COMPONENTS:

1. STEEL SLOTTED SUPPORT SYSTEMS WITH METALLICCOATINGS.

2. NON-METALLIC SLOTTED SUPPORT SYSTEMS.3. RACEWAY AND CABLE SUPPORTS.4. STEEL AND MALLEABLE-IRON CONDUIT AND CABLE

HANGERS, CLAMPS AND ASSOCIATED ACCESSORIES.5. SUPPORT FOR NON-ARMORED CONDUCTORS AND CABLES

IN VERTICAL CONDUIT RISERS.6. STRUCTURAL STEEL FOR FABRICATED SUPPORTS AND

RESTRAINTS.7. MOUNTING, ANCHORING AND ATTACHMENT COMPONENTS:

a. POWDER-ACTUATED FASTENERS.b. MECHANICAL-EXPANSION ANCHORS.c. CONCRETE INSERTS.d. CLAMPS FOR ATTACHMENT TO STEEL STRUCTURAL

ELEMENTS.e. ALL STEEL, SPRINGHEAD TOGGLE BOLTS.f. THREADED HANGER RODS.

B. FABRICATED METAL EQUIPMENT SUPPORT ASSEMBLIES:WELDED OR BOLTED STEEL SHAPES.

END OF SECTION 260529

SECTION 260533 - RACEWAYS AND BOXES FOR ELECTRICALSYSTEMS

PART 1 - GENERAL

1.1 MATERIALSA. METAL CONDUITS, TUBING AND FITTINGS:

1. GRC.2. EMT.3. FMC: ZINC-COATED STEEL.4. LFMC.5. FITTINGS:

a. EMT: STEEL, SETSCREW OR COMPRESSION TYPE.b. EXPANSION FITTINGS.

B. NONMETALLIC CONDUITS, TUBING AND FITTINGS:1. RNC.2. FITTINGS: MATCH CONDUIT.3. SOLVENT CEMENTS AND ADHESIVE PRIMERS SHALL HAVE A

VOC CONTENT OF 510 AND 550 G/L OR LESS,RESPECTIVELY.

C. METAL WIREWAYS AND AUXILIARY GUTTERS: SHEET METALWITH SCREW COVERS.

D. SURFACE METAL RACEWAYS: LEGRAND/WIREMOLD STEEL2000 SERIES (CONFIRM FINISH WITH STARBUCKS)

E. BOXES, ENCLOSURES AND CABINETS:1. METAL OUTLET AND DEVICE BOXES:2. METAL FLOOR BOXES: CAST METAL, FULLY ADJUSTABLE.3. LUMINAIRE OUTLET BOXES: NONADJUSTABLE, DESIGNED

FOR ATTACHMENT OF LUMINAIRE WEIGHING 50 LB (23 KG).4. SMALL SHEET METAL PULL AND JUNCTION BOXES.5. CAST-METAL ACCESS, PULL AND JUNCTION BOXES.6. BOX EXTENSIONS.7. GANGABLE BOXES.8. HINGED-COVER ENCLOSURES: METAL.9. CABINETS: GALVANIZED STEEL.

1.2 RACEWAY APPLICATIONA. OUTDOORS:

1. EXPOSED: GRC.2. CONCEALED, ABOVEGROUND: RNC, TYPE EPC-40-PVC.3. UNDERGROUND: RNC, TYPE EPC-40-PVC, DIRECT BURIED.4. CONNECTION TO VIBRATING EQUIPMENT: LFMC.5. BOXES AND ENCLOSURES, ABOVEGROUND: TYPE 3R OR

TYPE 4.B. INDOORS:

1. EXPOSED, NOT SUBJECT TO PHYSICAL DAMAGE: EMT.2. EXPOSED, NOT SUBJECT TO SEVERE PHYSICAL DAMAGE:

EMT.3. CONCEALED: EMT (OR MC CABLE).4. CONNECTION TO VIBRATING EQUIPMENT: FMC, EXCEPT

LFMC IN DAMP OR WET LOCATIONS.5. DAMP OR WET LOCATIONS: GRC.6. BOXES AND ENCLOSURES: TYPE 1, EXCEPT TYPE 4

NON-METALLIC IN DAMP OR WET LOCATIONS.C. MINIMUM RACEWAY SIZE: 1/2-INCH (16-MM) TRADE SIZE.D. RACEWAY FITTINGS: COMPATIBLE WITH RACEWAYS AND

SUITABLE FOR USE AND LOCATION.1. RIGID AND INTERMEDIATE STEEL CONDUIT: THREADED

RIGID STEEL CONDUIT FITTINGS.2. PVC EXTERNALLY COATED, RIGID STEEL CONDUITS:

FITTINGS LISTED FOR USE WITH THIS TYPE OF CONDUIT.3. EMT: SETSCREW OR COMPRESSION FITTINGS.4. FLEXIBLE CONDUIT: FITTINGS LISTED FOR USE WITH

FLEXIBLE CONDUIT.

END OF SECTION 260533

SECTION 260544 - SLEEVES AND SLEEVE SEALS FOR ELECTRICALRACEWAYS AND CABLING

1.1 MATERIALSA. SLEEVES:

1. SCHEDULE 40 STEEL PIPE.2. CAST-IRON PIPE.3. GALVANIZED-STEEL SHEET FOR CONDUITS PENETRATING

NON-FIRE-RATED GYPSUM-BOARD ASSEMBLIES.4. MOLDED-PE OR -PP PIPE.5. GALVANIZED-STEEL SHEET FOR RECTANGULAR OPENINGS.

B. HYDRAULIC-CEMENT GROUT.C. SILICONE SEALANTS:

1. SINGLE-COMPONENT, SILICONE-BASED, NEUTRAL-CURINGELASTOMERIC SEALANT.

2. MULTI-COMPONENT, SILICONE-BASED LIQUID ELASTOMERICNON-SHRINKING FOAM.

3. VOC CONTENT OF 250 G/L OR LESS.

END OF SECTION 260544

SECTION 260553 - IDENTIFICATION FOR ELECTRICAL SYSTEMS

1.1 QUALITY ASSURANCEA. COMPLY WITH ANSI A13.1 AND IEEE C2.

1.2 PRODUCTSA. POWER AND CONTROL RACEWAY IDENTIFICATION: WRITE-ON

TAGS.B. POWER AND CONTROL CABLE IDENTIFICATION:

SNAP-AROUND LABELS.C. CONDUCTOR IDENTIFICATION: COLOR-CODING CONDUCTOR

TAPE.D. FLOOR MARKING TAPE: 2-INCH- (50-MM-) WIDE

PRESSURE-SENSITIVE VINYL TAPE.E. UNDERGROUND-LINE WARNING TAPE: DETECTABLE

THREE-LAYER LAMINATE.F. WARNING LABELS AND SIGNS: SELF-ADHESIVE WARNING

LABELS.G. INSTRUCTION SIGNS: ADHESIVE FILM.H. EQUIPMENT IDENTIFICATION LABELS: ADHESIVE FILM.

END OF SECTION 260553

SECTION 260923 - LIGHTING CONTROL DEVICES

1.1 PRODUCTS:A. TIME SWITCHES: ASTRONOMIC TIME, SEVEN-DAY

PROGRAMMABLE WITH MINIMUM 8 ON/OFF SET POINTS PER 24HOUR SCHEDULE.

B. CONTROL CABLES:1. POWER CABLES: NOT SMALLER THAN NO. 12 AWG.2. CLASSES 2 AND 3 CONTROL CABLES: STRANDED-COPPER

CONDUCTORS, NOT SMALLER THAN NO. 18 AWG.3. CLASS 1 CONTROL CABLES: STRANDED-COPPER

CONDUCTORS, NOT SMALLER THAN NO. 14 AWG.

END OF SECTION 260923

SECTION 262416 - PANELBOARDS

1.1 QUALITY ASSURANCEA. MANUFACTURER QUALIFICATIONS: ISO 9001 OR 9002

CERTIFIED.1.2 PRODUCTS

A. GENERAL REQUIREMENTS FOR PANELBOARDS:1. CONSTRUCTED TO WITHSTAND SEISMIC FORCES.2. ENCLOSURES: SURFACE MOUNTED.

a. FRONT: HINGED COVER WITH KEY LOCK.b. DIRECTORY CARD.

3. INCOMING MAINS: AS NEEDED.4. PHASE, NEUTRAL, AND GROUND BUSES: TIN-PLATED

ALUMINUM.5. CONDUCTOR CONNECTORS:

a. MATERIAL: TIN-PLATED ALUMINUM.b. MAIN AND NEUTRAL LUGS: MECHANICAL TYPE.c. FEED-THROUGH LUGS: MECHANICAL TYPE.

6. PERCENTAGE OF FUTURE SPACE CAPACITY: TENPERCENT.

7. SERVICE EQUIPMENT LABEL FOR PANELBOARDSINCORPORATING ONE OR MORE MAIN SERVICEDISCONNECTING AND OVERCURRENT PROTECTIVEDEVICES.

B. PANELBOARD OR LOAD CENTER SHORT-CIRCUIT CURRENTRATING: FULLY RATED TO INTERRUPT SYMMETRICALSHORT-CIRCUIT CURRENT AVAILABLE AT TERMINALS. LISTEDSERIES RATED SYSTEM MAY BE USED IF APPROVED BY EORTO LIMIT FAULT TO BELOW 22K AIC FOR GFI BREAKERS.1. MAINS: LUGS ONLY.2. BRANCH OVERCURRENT PROTECTIVE DEVICES FOR

CIRCUIT-BREAKER FRAME3. SIZES 125 A AND SMALLER: PLUG-IN CIRCUIT BREAKERS.

C. DISCONNECTING AND OVERCURRENT PROTECTIVE DEVICES:1. CIRCUIT BREAKERS: THERMAL-MAGNETIC TYPES.2. GFI CIRCUIT BREAKERS: RATED FOR PERSONNEL.3. OPTIONS AND TYPES AS NEEDED.

F. IDENTIFICATION:1. PANELBOARD LABELS: MANUFACTURER'S NAME AND

TRADEMARK, VOLTAGE, AMPERAGE, NUMBER OF PHASES,ARC FLASH HAZARD AND NUMBER OF POLES SHALL BELOCATED ON THE INTERIOR OF THE PANELBOARD DOOR.

2. BREAKER LABELS: FACEPLATE SHALL LIST CURRENTRATING, UL AND IEC CERTIFICATION STANDARDS, AND AICRATING.

3. CIRCUIT DIRECTORY: DIRECTORY CARD INSIDEPANELBOARD DOOR, MOUNTED IN TRANSPARENT CARDHOLDER.

1.3 FIELD QUALITY CONTROLA. TESTING: BY CONTRACTOR.

END OF SECTION 262416

SECTION 262713 - ELECTRICITY METERING

1.1 EQUIPMENT FOR ELECTRICITY METERING BY UTILITY COMPANYA. UTILITY-COMPANY-COMPLIANT CURRENT-TRANSFORMER

CABINETS: COMPLY WITH REQUIREMENTS OFELECTRICAL-POWER UTILITY COMPANY.

B. METER SOCKETS: COMPLY WITH REQUIREMENTS OFELECTRICAL-POWER UTILITY COMPANY.

END OF SECTION 262713

SECTION 262726 - WIRING DEVICES

1.1 PRODUCTSA. RECEPTACLES: DUPLEX, 125 V, 20 A.

1. STRAIGHT BLADE: CONVENIENCE AND ISOLATED GROUND.2. GFCI: FEED THROUGH.3. TWIST-LOCKING TYPE WITH ISOLATED-GROUND TERMINAL.4. OTHERS, AS DEFINED IN PLAN NOTES.

B. CORD AND PLUG SETS: MATCH VOLTAGE AND CURRENTRATINGS AND NUMBER OF CONDUCTORS TO REQUIREMENTSOF EQUIPMENT BEING CONNECTED.

C. TOGGLE SWITCHES: 120/277 V, 20 A.D. WALL PLATES:

1. MATERIAL FOR WORKROOM: SATIN-FINISHED STAINLESSSTEEL.

2. MATERIAL FOR BAR: SATIN-FINISHED STAINLESS STEEL.3. MATERIAL FOR CUSTOMER AREAS: THERMOPLASTIC WITH

COLOR OPTION PER STARBUCKS.E. MULTI-OUTLET ASSEMBLIES: MANUFACTURED AND LISTED

METAL RACEWAYS.F. FINISHES:

1. CONNECTED TO NORMAL POWER SYSTEM: WHITE WITHSTAINLESS STEEL PLATE OR TO MATCH WALL PLATE.

2. CONNECTED TO EMERGENCY POWER SYSTEM: RED.3. ISOLATED-GROUND RECEPTACLES: ORANGE.

END OF SECTION 262726

SECTION 262816 - ENCLOSED SWITCHES AND CIRCUIT BREAKERS

1.1 PRODUCTSA. FUSIBLE SWITCHES:

1. HEAVY DUTY, SINGLE THROW, 240-V, 600V AC, 800 A ANDSMALLER: UL 98 AND NEMA RATING AS NEEDED AND PERCODE, TYPE GD.

2. ACCESSORIES, WHERE NEEDED:a. EQUIPMENT GROUND KIT.b. NEUTRAL KIT.c. ISOLATED GROUND KIT.d. CLASS R FUSE KIT.e. AUXILIARY CONTACT KIT.f. HOOKSTICK HANDLE.g. LUGS: MECHANICAL.h. SERVICE-RATED SWITCHES.i. ACCESSORY CONTROL POWER.

B. NON-FUSIBLE SWITCHES:1. HEAVY DUTY, SINGLE THROW, 240-V, 600V AC, 600 A AND

SMALLER: UL 98 AND NEMA RATING AS NEEDED AND PERCODE, TYPE GD.

2. ACCESSORIES, WHERE NEEDED:a. EQUIPMENT GROUND KIT.b. NEUTRAL KIT.c. ISOLATED GROUND KIT.c. AUXILIARY CONTACT KIT.e. HOOKSTICK HANDLE.f. LUGS: MECHANICAL.g. ACCESSORY CONTROL POWER.

C. MOLDED-CASE CIRCUIT BREAKERS:1. THERMAL-MAGNETIC TYPE.2. GFCI TYPE.3. FEATURES AND ACCESSORIES:

a. LUGS: MECHANICAL.b. TYPE SWD FOR SWITCHING FLUORESCENT LIGHTING

LOADS.c. TYPE HID FOR FEEDING FLUORESCENT AND

HIGH-INTENSITY DISCHARGE LIGHTING CIRCUITS.d. GROUND-FAULT PROTECTION: PERSONNEL RATED.

1.2 FIELD QUALITY CONTROLA. TESTING: BY CONTRACTOR.

END OF SECTION 262816

ESF17-00829Page 2 of 9

City of KirklandReviewed by J Tumelson02/27/2017

2401 UTAH AVENUE SOUTHSEATTLE, WASHINGTON 98134

(206) 318-1575

SHEET NUMBER:

SHEET TITLE:

SCALE: AS SHOWN

STORE #:

-

PROJECT #:

ISSUE DATE:DESIGN MANAGER:

DRAWN BY:CHECKED BY:

08298-034

01/09/2017

HO

UG

HTO

N P

LAZA

6733

108

th A

ve. N

EK

irkla

nd, W

A 9

8033

PR

OJE

CT

NA

ME

:

PR

OJE

CT

AD

DR

ES

S:

3333

John Park

Chris Rensch

Revision ScheduleRev Date By Description

STARBUCKS COFFEECOMPANY

DESIGNER:

C 2011 STARBUCKS COFFEE COMPANY

R

THESE DRAWINGS AND SPECIFICATIONS ARECONFIDENTIAL AND SHALL REMAIN THE SOLEPROPERTY OF STARBUCKS CORPORATION,

WHICH IS THE OWNER OF THE COPYRIGHT INTHIS WORK. THEY SHALL NOT BE REPRODUCED

(IN WHOLE OR IN PART), SHARED WITH THIRDPARTIES OR USED IN ANY MANNER ON OTHERPROJECTS OR EXTENSIONS TO THIS PROJECTWITHOUT THE PRIOR WRITTEN CONSENT OF

STARBUCKS CORPORATION. THESE DRAWINGSAND SPECIFICATIONS ARE INTENDED TO

EXPRESS DESIGN INTENT FOR APROTOTYPICAL STARBUCKS STORE (WHICH IS

SUBJECT TO CHANGE AT ANYTIME) AND DO NOTREFLECT ACTUAL SITE CONDITIONS. NEITHER

PARTY SHALL HAVE ANY OBLIGATION NORLIABILITY TO THE OTHER (EXCEPT STATED

ABOVE) UNTIL A WRITTEN AGREEMENT IS FULLYEXECUTED BY BOTH PARTIES.

STARBUCKS TEMPLATE VERSION i2014.10.20

LLC

111 AVE. C SUITE 104, SNOHOMISH, WA 98290PH: 360-863-6677

www.renschengineering.comFX: 360-863-3565

E-0003

Yumi RothOliver Smith

ELECTRICAL ENERGYFORMS

ESF17-00829Page 3 of 9

City of KirklandReviewed by J Tumelson02/27/2017

2401 UTAH AVENUE SOUTHSEATTLE, WASHINGTON 98134

(206) 318-1575

SHEET NUMBER:

SHEET TITLE:

SCALE: AS SHOWN

STORE #:

-

PROJECT #:

ISSUE DATE:DESIGN MANAGER:

DRAWN BY:CHECKED BY:

08298-034

01/09/2017

HO

UG

HTO

N P

LAZA

6733

108

th A

ve. N

EK

irkla

nd, W

A 9

8033

PR

OJE

CT

NA

ME

:

PR

OJE

CT

AD

DR

ES

S:

3333

John Park

Chris Rensch

Revision ScheduleRev Date By Description

STARBUCKS COFFEECOMPANY

DESIGNER:

C 2011 STARBUCKS COFFEE COMPANY

R

THESE DRAWINGS AND SPECIFICATIONS ARECONFIDENTIAL AND SHALL REMAIN THE SOLEPROPERTY OF STARBUCKS CORPORATION,

WHICH IS THE OWNER OF THE COPYRIGHT INTHIS WORK. THEY SHALL NOT BE REPRODUCED

(IN WHOLE OR IN PART), SHARED WITH THIRDPARTIES OR USED IN ANY MANNER ON OTHERPROJECTS OR EXTENSIONS TO THIS PROJECTWITHOUT THE PRIOR WRITTEN CONSENT OF

STARBUCKS CORPORATION. THESE DRAWINGSAND SPECIFICATIONS ARE INTENDED TO

EXPRESS DESIGN INTENT FOR APROTOTYPICAL STARBUCKS STORE (WHICH IS

SUBJECT TO CHANGE AT ANYTIME) AND DO NOTREFLECT ACTUAL SITE CONDITIONS. NEITHER

PARTY SHALL HAVE ANY OBLIGATION NORLIABILITY TO THE OTHER (EXCEPT STATED

ABOVE) UNTIL A WRITTEN AGREEMENT IS FULLYEXECUTED BY BOTH PARTIES.

STARBUCKS TEMPLATE VERSION i2014.10.20

LLC

111 AVE. C SUITE 104, SNOHOMISH, WA 98290PH: 360-863-6677

www.renschengineering.comFX: 360-863-3565

0 2' 4' 8'

N

Jasen D. SnyderGloriana Huhta

E-1100

ELECTRICALUNDERSLAB PLAN

KEY NOTESGENERAL NOTES #

1. ROUTE CONDUITS TO POWER PANELS. TERMINATE IN PANELS WITH APPROPRIATEFITTINGS AND BUSHINGS. FURNISH AND INSTALL J-BOXES / WIRE-WAYS TOACCOMPLISH THIS IF NECESSARY.

2. NOTE NOT USED.

3. SEE ARCHITECTURAL PENETRATION PLAN FOR DIMENSIONED LOCATIONS.

4. INSTALL FLOOR BOX (HUBBELL #S1CFB OR EQUAL) TO ALLOW FLUSH FLOOR BOXCOVER. COORDINATE WITH STARBUCKS CM AND SEE ARCHITECT DETAILS FOREXACT LOCATION.

5. 4" DIAMETER CONDUIT RACEWAY BELOW FLOOR WITH FULL SWEEP ELBOWSSTUBBING UP THROUGH FLOOR WITH BUSHINGS, PROVIDED FOR CHILLED BEVERAGEWATER SYSTEM. COORDINATE STUB-UPS LOCATION WITH GC & STARBUCKS CM.

A. CONTRACTOR IS TO FURNISH AND INSTALL PULLSTRINGS THROUGH ALLCONDUITS. STUB CONDUITS UP IN CABINET AREAS AS DIMENSIONED ON THEARCHITECTURAL PENETRATION PLAN. NOTE WHERE CONDUITS ARE SHOWNWITHIN WALLS, STUB UP IN THE APPROXIMATE LOCATION SHOWN WITHINTHE WALL.

B. ALL UNDERSLAB (POWER & LAN) CONDUITS SHALL BE MIN. 3/4" CONDUIT(EXCEPT WHERE OTHERWISE INDICATED). ALL STUB UPS & ELBOWS FORPOWER AND LAN SHALL BE RIGID STEEL.

C. SEE PLUMBING PLANS FOR ADDITIONAL UNDER FLOOR ITEMS ANDCOORDINATE WITH PLUMBING CONTRACTOR (TYPICAL).

D. CONTRACTOR SHALL PROVIDE CORE DRILLS, CONCRETE CUTTING ANDPATCHING WHERE NEEDED TO PENETRATE EXISTING CONCRETEFOOTINGS/SLAB. COORDINATE WITH STARBUCKS AND GENERALCONTRACTOR TO DETERMINE SPECIFIC METHODS AND EXACT LOCATIONS.MAINTAIN STRUCTURAL INTEGRITY OF FLOOR AND COORDINATE WITHSTRUCTURAL.

E. PROTECT CONDUIT OPENINGS FROM CONTAMINANTS AND FROM BEINGDAMAGED AFTER CONDUITS ARE INSTALLED AND PRIOR TO BACKFILL.

F. IF POSSIBLE, ALL STUB UPS SHALL BE 4" ON CENTER MINIMUM.

G. LABEL ALL CONDUITS SO VENDORS WILL KNOW WHICH CONDUITS TO USE,SUCH AS "TO DT SIGNAGE" OR "TO SOUTH SIDE OF DT WINDOW FOR POSEQUIPMENT".

H. CONDUCTORS ARE NOT SHOWN (TYPICAL).

LEGEND

BELOW FLOOR / SLAB CONDUIT (NOT TO BE INSTALLEDWITHIN CONCRETE)

CONDUIT STUB-UP

1-LV-ESPRESSO

CONDUIT: LV = LOW VOLTAGE; PWR = POWER

DESCRIPTION OF CIRCUITS TOBE ROUTED THROUGH CONDUIT

QUANTITY OF CONDUIT(S)

ELECTRICAL UNDERSLAB PLAN

ESF17-00829Page 4 of 9

City of KirklandReviewed by J Tumelson02/27/2017

2401 UTAH AVENUE SOUTHSEATTLE, WASHINGTON 98134

(206) 318-1575

SHEET NUMBER:

SHEET TITLE:

SCALE: AS SHOWN

STORE #:

-

PROJECT #:

ISSUE DATE:DESIGN MANAGER:

DRAWN BY:CHECKED BY:

08298-034

01/09/2017

HO

UG

HTO

N P

LAZA

6733

108

th A

ve. N

EK

irkla

nd, W

A 9

8033

PR

OJE

CT

NA

ME

:

PR

OJE

CT

AD

DR

ES

S:

3333

John Park

Chris Rensch

Revision ScheduleRev Date By Description

STARBUCKS COFFEECOMPANY

DESIGNER:

C 2011 STARBUCKS COFFEE COMPANY

R

THESE DRAWINGS AND SPECIFICATIONS ARECONFIDENTIAL AND SHALL REMAIN THE SOLEPROPERTY OF STARBUCKS CORPORATION,

WHICH IS THE OWNER OF THE COPYRIGHT INTHIS WORK. THEY SHALL NOT BE REPRODUCED

(IN WHOLE OR IN PART), SHARED WITH THIRDPARTIES OR USED IN ANY MANNER ON OTHERPROJECTS OR EXTENSIONS TO THIS PROJECTWITHOUT THE PRIOR WRITTEN CONSENT OF

STARBUCKS CORPORATION. THESE DRAWINGSAND SPECIFICATIONS ARE INTENDED TO

EXPRESS DESIGN INTENT FOR APROTOTYPICAL STARBUCKS STORE (WHICH IS

SUBJECT TO CHANGE AT ANYTIME) AND DO NOTREFLECT ACTUAL SITE CONDITIONS. NEITHER

PARTY SHALL HAVE ANY OBLIGATION NORLIABILITY TO THE OTHER (EXCEPT STATED

ABOVE) UNTIL A WRITTEN AGREEMENT IS FULLYEXECUTED BY BOTH PARTIES.

STARBUCKS TEMPLATE VERSION i2014.10.20

LLC

111 AVE. C SUITE 104, SNOHOMISH, WA 98290PH: 360-863-6677

www.renschengineering.comFX: 360-863-3565

0 2' 4' 8'

N

A. PROVIDE ALL BRANCH CIRCUITING AND DEVICES, EVEN IF NOT SHOWN.PROVIDE ALL WIRING AND WIRE QUANTITIES TO ACCOMPLISHCIRCUITING TO MEET SPEC REQUIREMENTS AND APPLICABLE CODES.

B. ALL IS NEW UNLESS OTHERWISE NOTED.

C. WIRE QUANTITIES ARE NOT SHOWN. FURNISH & INSTALL PER NOTES,CODE AND AS NEEDED WITH DEDICATED NEUTRALS FOR ALL GFIBREAKER PROTECTED CIRCUITS (TO PREVENT FALSE TRIPS). INSTALL ANEUTRAL CONDUCTOR FOR ALL CIRCUITS INCLUDING 208V 1-PHASELOADS TO ALLOW FOR CONTROL POWER AND FOR FUTURE UPGRADES.

D. NOT ALL CONDUITS/CIRCUITS CALLED FOR IN NOTES ARE SHOWN INPLAN VIEW.

E. VERIFY ALL EQUIPMENT RATINGS IN FIELD AND ADJUST CIRCUITBREAKER RATINGS AS MAY BE NEEDED. CONFIRM CIRCUIT VOLTAGE ISAT A VOLTAGE RECOMMENDED BY EQUIPMENT MANUFACTURERS. IFNEEDED, THE CONTRACTOR SHALL PROVIDE AND INSTALL BUCK-BOOSTTRANSFORMERS TO BE LOCATED IN ACCESSIBLE LOCATIONS ABOVE THECEILING WITHIN 6' OF THE ELECTRICAL PANEL. IF LOCAL CODES DO NOTALLOW INSTALLATION ABOVE THE CEILINGS, THE TRANSFORMERS SHALLBE MOUNTED TO THE WALL JUST BELOW THE CEILING. ACCEPTABLETRANSFORMERS INCLUDE ACME. FURNISH AND INSTALL ANY ADDITIONALO.C.P. NEEDED.

F. SEE ARCH. SHEETS FOR PAINTING AND COLORS FOR ANY EXPOSEDJ-BOXES, CONDUIT, ETC. (SEE GENERAL NOTES ON E-0001 FOR EXPOSEDRACEWAY REQUIREMENTS.)

G. VERIFY ACTUAL RATINGS/LISTINGS OF EQUIPMENT AND ADJUSTBREAKER, OUTLET & CIRCUIT SIZES/RATINGS AS MAY BE NEEDED PERCODE.

H. IF ANY CORD AND PLUG IS OBSTRUCTED BY CABINET PARTITIONS,PROVIDE ADDITIONAL OUTLET.

E-1101

Yumi RothGloriana Huhta

POWER PLAN

SHEET NOTES

ELECTRICAL POWER REQUIREMENTS NOTED MAY BE SATISFIED BYEXISTING ELECTRICAL POWER SYSTEM AND RECEPTACLES (FIELDVERIFY). REUSED RECEPTACLES SHALL BE IN GOOD CONDITION ANDLOCATED TO NOT OBSTRUCT NEW CABINETS AND EQUIPMENT. REPLACEEXISTING RECEPTACLES WHERE NEEDED/REQUIRED FOR THERENOVATION. REFERENCE GFI NOTES FOR ADDITIONAL REQUIREMENTS.

IMPORTANTGFI AND CIRCUIT NOTES:

1. 120V OUTLETS AS INDICATED IN BACK BAR, FRONT BAR, WORKROOM,AS DEFINED BY INSPECTOR/AHJ AND AS INDICATED ELSEWHERESHALL BE GFI PROTECTED. GFCI RECEPTACLES ARE ONLY ALLOWEDIF THEY CAN BE LOCATED ABOVE COUNTER AND ACCESSIBLE. ALLOTHER GFI PROTECTED OUTLETS (NOT ACCESSIBLE) SHALL BEPROVIDED WITH EITHER A GFI BREAKER (WITH NEW DEDICATEDNEUTRAL TO PREVENT FALSE TRIPPING) OR A GFCI DEVICE WITHTEST SWITCH MOUNTED IN A 2 GANG BOX ABOVE COUNTER IN ANACCESSIBLE LOCATION AND WIRED TO PROTECT RECEPTACLEBELOW.

2. CONTRACTOR SHALL COORDINATE WITH AHJ AND PROVIDE GFIPROTECTION OF ADDITIONAL EXISTING RECEPTACLES IF REQUIRED.SEE NOTE 1 FOR OPTIONS.

3. THE ABOVE ARE IN ADDITION TO ANY SHOWN IN PLANS.

RECEPTACLES AND FACEPLATE COLORS SHALL BE:

BAR AREA: STAINLESS STEEL PLATES WITH WHITE OUTLETS.

SEATING AREA: CONFIRM WITH DM.

WORKROOM AREA: STAINLESS STEEL PLATES WITH WHITE OUTLETS.

POWER PLAN

# POWER KEY NOTES1. RETAIL GRINDER / SCALE: PROVIDE 4-PLEX RECEPTACLE @ 26" AFF.

2. CONNECT TO EXISTING CIRCUIT(S) FOR RELOCATED EQUIPMENT (CONFIRM).

3. TWIN BREWER: NEMA 14-50R RECEPTACLE @ 26" AFF, 3/4"C-3#6 AND 1#10 GROUND,CONTRACTOR TO PROVIDE A NEMA 14-50P CORD CAP FOR THE BREWER, BRYANT OREQUAL.

4. FOR ESPRESSO MACHINE, FURNISH AND INSTALL NEMA 6-50R RECEPTACLE HUBBELLHBL9367 SERIES OR EQUAL AT 30" AFF. ROUTE 3/4" CONDUIT-(2) #6 AND (1) #10 GROUNDFROM MACHINE BACK TO PANEL. FURNISH AND INSTALL NEMA 6-50P ANGLED PLUG,HUBBELL HBL9368 SERIES OR EQUAL.

5. UNDER COUNTER REFRIGERATOR: PROVIDE RECEPTACLE @ 26" AFF.

6. REFRIGERATOR AND/OR FREEZER: RECEPTACLE @ 84" AFF.

7. ICE MACHINE (REMOTE COOLED): CONFIRM POWER REQUIREMENTS & INTERCONNECTINGWIRE FOR ICE MACHINE & REMOTE CONDENSER. PROVIDE RECEPTACLE @ 72" AFF ANDPOWER CONNECTION PER MANUFACTURER AND CODE REQUIREMENTS. CONFIRMMOUNTING HEIGHT.

8. FOODCASE: HARD WIRE EQUIPMENT CONNECTION. PROVIDE SEPARATE (1) 120V/15A AND(1) 220V/20A DEDICATED CIRCUITS.

9. DISHWASHER (HIGH TEMP): PROVIDE HARDWIRE CONNECTION TO DISHWASHER. F&I 3#8(90°) & GND IN FLEX METAL CONDUIT FROM J-BOX TO DISHWASHER W/ 4FT OF COILED FLEXBEHIND MACHINE TO ALLOW MOVING FOR CLEANING. CIRCUIT FROM PANEL TO J-BOX TOBE 3/4"C - 3#6 AND 1#10 GROUND.

10. CONVENIENCE RECEPTACLE @ 18" AFF.

11. CONNECT TO EXISTING CIRCUIT (CONFIRM).

12. COFFEE WARMERS: PROVIDE RECEPTACLE(S) @ 26" AFF.

13. BLENDERS: RECEPTACLES @ 26" AFF IN (2) DUPLEX BOXES.

14. FIZZIO: PROVIDE RECEPTACLE AT 26" AFF.

15. LOCATION OF DIGITAL SWITCHING. SEE E-1101 FOR FURTHER REQUIREMENTS ANDCIRCUITRY. NOT ALL SWITCHES ARE NECESSARILY SHOWN.

16. FILTER SYSTEM: PROVIDE A DUPLEX GFCI & QUAD GFCI 120V RECEPTACLES. FIELDVERIFY MOUNTING HEIGHTS.

17. CONFIRM IF EXISTING CONVENIENCE RECEPTACLE IS LOCATED AS SHOWN & PROVIDENEW ONE IF NOT (COORDINATE W/ GC).

18. SAFE: FURNISH AND INSTALL DUPLEX RECEPTACLE AND SECURITY J-BOX @ 18" AFF. GCTO F&I CABLING AND COORDINATE WITH DIEBOLD FOR SAFE INSTALLATION & SETUP.

19. HOT TAP: PROVIDE RECEPTACLE @ 26" AFF.

20. FURNISH AND INSTALL MAINTENANCE RECEPTACLE, LIGHT & SWITCH ABOVE CEILING ASNEEDED FOR HVAC UNITS. (FIELD VERIFY BEST LOCATIONS)

21. PROVIDE RECEPTACLE & BACKBOX FOR LAN CONNECTION @ 26" AFF FOR FUTURE USE.

22. RINSE SINK: PROVIDE RECEPTACLE @ 26" AFF.

23. POS: FURNISH AND INSTALL DUPLEX ISOLATED-GROUNDING TYPE RECEPTACLE @ 18"AFF., INCLUDING GREEN GROUNDING WIRE AND ISOLATED GROUNDING WIRE BACK TOSERVING POWER PANEL PER CODE. FURNISH AND INSTALL (1) J-BOX FOR DATA OUTLETAND (1) J-BOX FOR PHONE OUTLET @ 18" AFF.

24. NOTE NOT USED.

25. FLOOR BOX (HUBBELL #S1CFB OR EQUAL) W/ FLUSH FLOOR BOX COVER. CONNECT 3/4"FLEX CONDUIT VIA LB CONDULET AND ROUTE TO TABLE PLUGMOLD. COORD. W/ SBUX CMAND SEE ARCH DETAILS FOR EXACT LOCATION.

26. ALARM KEYPAD: @ 54" AFF. ROUTE CONDUIT IN WALL FROM J-BOX AND STUB UP ABOVECEILING.

27. BENCH SEAT WITH PRE-MOUNTED UL LISTED DUPLEX RECEPTACLE, USB PORT AND10FTPLUG & CORD. PROVIDE 120V DUPLEX RECEPTACLE AT 10"AFF TO CENTERLINE & CIRCUITAS NEEDED (CONFIRM W/ MANUFACTURER). SEE ARCH. PLANS & COORDINATE WITH GC.

28. STEEL PLUGMOLD MOUNTED UNDER COUNTERTOP (SEE ARCH. DETAILS).LEGRAND/WIREMOLD 2000 SERIES WITH LENGTH AS NEEDED, OUTLETS EVERY 24IN ONCENTER (NOT SHOWN) AND ACCESSORIES AS NEEDED. CONFIRM COLOR/INSTALL WITHCM.

29. WARMING OVEN: FURNISH & INSTALL NEMA 6-30R RECEPTACLE @ 28" AFF, & ALLNECESSARY CONDUIT, WIRE (#10CU., THWN) & CONNECTIONS BACK TO SERVING PANEL.

30. NITRO COLD BREW TAP: PROVIDE RECEPTACLE @ 26" AFF.

31. STUB UP POWER, DATA, PHONE AND SECURITY CONDUITS @ 6" AFF IN THIS LOCATION ASINDICATED ELSEWHERE (SEE ARCH. PLANS FOR DIMENSIONS). ROUTE ABOVE FLOORPOWER CONDUCTORS IN FLEXIBLE METAL CONDUIT WITH GROUND TIGHT TO WALL FROMRECEPTACLES TO NEAREST RIGID STUB-UP AND BACK TO SERVING POWER PANEL.ROUTE DATA, PHONE AND SECURITY CONDUITS UNDERFLOOR BACK TO DATA RACK NEARMANAGERS WORKSTATION. LABEL DATA AND PHONE CONDUITS "FOR DATA CABLING",PROVIDE INSULATED BUSHINGS, AND PROVIDE PULL STRING FROM END TO END. LABELSECURITY "CONDUIT FOR SECURITY" AND PROVIDE PULL STRING FROM END TO END.STUB UP LOCATIONS IN WALLS ARE NOT SHOWN.

32. LIGHTING CONTROL SYSTEM (LCS). SEE LUTRON CONTROL SHEETS & CONTROL NOTESON THIS SHEET. NOT ALL CONTROL COMPONENTS ARE SHOWN. F&I AS NEEDED FOR ACOMPLETE & OPERATIONAL SYSTEM. EC TO CONFIRM COMPONENTS W/ VENDOR &PROVIDE ALL WIRING AND MOUNTING AS NEEDED.

33. MO&P PRINTER/LABELER: PROVIDE ISOLATED GROUND RECEPTACLE AND BACKBOX FORLAN CONNECTION @ 26" AFF.

34. CUP LABELER: PROVIDE ISOLATED GROUND RECEPTACLE AND BACKBOX FOR LANCONNECTION @ 26" AFF.

35. FIREPLACE: INSTALL NEW SWITCH AND ROUTE CONTROL TO EXISTING GAS FIREPLACE.FIELD VERIFY REQUIREMENTS & LABEL SWITCH.

36. PROVIDE J-BOX AT 26" AFF WITH CIRCUITS PULLED INTO J-BOX FOR FUTURE LOADS.

37. OASIS CASE: PROVIDE 20A, 120V 1Ø NEMA 5-20R RECEPTACLE AND CIRCUIT. CONFIRMCORD/PLUG AS NEEDED. (CONFIRM W/ MANUFACTURER).

38. FLOOR BOX (HUBBELL #S1CFB OR EQUAL) W/ FULLY RECESSED DUPLEX RECEPTACLES.PROVIDE BRASS FLUSH, FLIP LID COVER PLATES. COORD. W/SBUX CM AND SEE ARCHDETAILS FOR EXACT LOCATION.

39. WATER CHILLER: 120V/1Ø NEMA 5-30R RECEPTACLE AND CIRCUIT. CONFIRM CORD/PLUGAS NEEDED. (CONFIRM W/ MANUFACTURER).

Scale: NTS

LAN/POWER/PHONE/SECURITY SYSTEM DIAGRAM1

ESF17-00829Page 5 of 9

City of KirklandReviewed by J Tumelson02/27/2017

2401 UTAH AVENUE SOUTHSEATTLE, WASHINGTON 98134

(206) 318-1575

SHEET NUMBER:

SHEET TITLE:

SCALE: AS SHOWN

STORE #:

-

PROJECT #:

ISSUE DATE:DESIGN MANAGER:

DRAWN BY:CHECKED BY:

08298-034

01/09/2017

HO

UG

HTO

N P

LAZA

6733

108

th A

ve. N

EK

irkla

nd, W

A 9

8033

PR

OJE

CT

NA

ME

:

PR

OJE

CT

AD

DR

ES

S:

3333

John Park

Chris Rensch

Revision ScheduleRev Date By Description

STARBUCKS COFFEECOMPANY

DESIGNER:

C 2011 STARBUCKS COFFEE COMPANY

R

THESE DRAWINGS AND SPECIFICATIONS ARECONFIDENTIAL AND SHALL REMAIN THE SOLEPROPERTY OF STARBUCKS CORPORATION,

WHICH IS THE OWNER OF THE COPYRIGHT INTHIS WORK. THEY SHALL NOT BE REPRODUCED

(IN WHOLE OR IN PART), SHARED WITH THIRDPARTIES OR USED IN ANY MANNER ON OTHERPROJECTS OR EXTENSIONS TO THIS PROJECTWITHOUT THE PRIOR WRITTEN CONSENT OF

STARBUCKS CORPORATION. THESE DRAWINGSAND SPECIFICATIONS ARE INTENDED TO

EXPRESS DESIGN INTENT FOR APROTOTYPICAL STARBUCKS STORE (WHICH IS

SUBJECT TO CHANGE AT ANYTIME) AND DO NOTREFLECT ACTUAL SITE CONDITIONS. NEITHER

PARTY SHALL HAVE ANY OBLIGATION NORLIABILITY TO THE OTHER (EXCEPT STATED

ABOVE) UNTIL A WRITTEN AGREEMENT IS FULLYEXECUTED BY BOTH PARTIES.

STARBUCKS TEMPLATE VERSION i2014.10.20

LLC

111 AVE. C SUITE 104, SNOHOMISH, WA 98290PH: 360-863-6677

www.renschengineering.comFX: 360-863-3565

0 2' 4' 8'

N

SHEET NOTES

A. ALL IS NEW UNLESS OTHERWISE NOTED.

B. COORDINATE WITH GC AS TO WHOM IS TO PROVIDE ALLLIGHT FIXTURES AND LAMPS UNLESS NOTED OTHERWISE.

C. REFER TO ARCHITECTURAL PLANS FOR EXACT FIXTURELOCATIONS AND MOUNTING HEIGHTS.

D. ADJUST FOCUS OF ALL TRACK AND RECESSED DIRECTIONALLIGHTING TO FULLY ILLUMINATE ALL ARTWORK, MENUBOARDS AND MERCH BAYS.

E. ALL LAMPING IN FOOD PREP AREAS SHALL BESHATTERPROOF LAMPS IF THE FIXTURE DOES NOT HAVE ALENS.

F. CONDUCTOR QUANTITIES ARE NOT SHOWN. F&I PER CODEWITH SWITCHING AS INDICATED BY LETTER DESIGNATION,NOTE, OR LOCAL SWITCH. CONFIRM WIRING DIAGRAMS ANDREQUIREMENTS OF ANY SPECIAL LIGHTING CONTROLS.

E-1102

Yumi RothGloriana Huhta

LIGHTING PLAN

LIGHTING KEY NOTES#

LIGHTING PLAN

1. LIGHTING CONTROL SYSTEM (LCS). SEE LUTRON CONTROL SHEETS &CONTROL NOTES ON E-6001. NOT ALL CONTROL COMPONENTS ARE SHOWN.F&I AS NEEDED FOR A COMPLETE & OPERATIONAL SYSTEM. EC TO CONFIRMCOMPONENTS W/ VENDOR & PROVIDE ALL WIRING AND MOUNTING ASNEEDED.

2. NIGHT LIGHT (NL) & EMERGENCY FIXTURES TO BE CONNECTED TOCONSTANT HOT LEG OF LIGHTING CIRCUIT SERVING AREA (AHEAD OF ANYLIGHTING CONTROLS).

3. MOTION DETECTOR SWITCH MOUNTED 48" AFF AND 7-1/2" FROM OUTSIDEEDGE OF DOOR FRAME. COORDINATE LOCATION WITH TILES, STUDS ANDOTHER OBJECTS. CONFIRM LOCATION WITH GC.

4. PHOTOCELL TO CONTROL DAYLIGHT ZONES BY DIMMING FIXTURES WITHINZONES AS INDICATED TO MEET STATE ENERGY CODE FOR AUTOMATICDAYLIGHT CONTROL. FIELD ADJUST SENSOR AS NEEDED.

5. EMERGENCY FIXTURE TO BE SURFACE MOUNTED FACING DOWN. FIELDADJUST IF PENDANT MOUNT IS REQUIRED.

6. NOT ALL SWITCHES NEEDED ARE SHOWN. SEE LUTRON CONTROL SHEETS &CONTROL NOTES ON THIS SHEET.

7. CONNECT FIXTURE TO CONSTANT HOT OF EXTERIOR LIGHTING CIRCUIT.

8. EXISTING EXIT SIGN/LIGHT BATTERY BACKUP FIXTURE.

9. SEE ARCH. DRAWING FOR LED STRIP LIGHT MOUNTING LOCATION.COORDINATE DRIVER LOCATION IN FIELD AND HIDE FROM PUBLIC VIEW.MAKE CONNECTIONS TO LED STRIP LIGHTS PER MANUFACTURERREQUIREMENTS.

10. NOTE NOT USED.

11. EXTERIOR LIGHTS ARE TO BE CONTROLLED BY PE CELL (SEE LCS DETAIL).

12. CONTROLLED NIGHT LIGHT (CNL): FIXTURE CONTROLS TO BE PROGRAMMEDTO ALLOW NORMAL DL/DIM CONTROL DURING BUSINESS HOURS & REMAINON DURING UNOCCUPIED HOURS.

13. CONFIRM IF EXISTING MOTION DETECTOR SWITCH IS LOCATED AS SHOWNAND IN GOOD CONDITION. PROVIDE NEW ONE IF NOT AND CONNECT TO NEWCIRCUIT AND LIGHTS AS SHOWN (COORDINATE W/ GC).

14. FIELD CUT TRACK TO LENGTH SHOWN.

15. CONNECT TRACKS TO MAKE LENGTH AS SHOWN.

THE CONTRACTOR SHALL COORDINATE WITH LUTRONCONTROLS REPRESENTATIVE TO TEST TO ENSURECONTROL DEVICES, COMPONENTS, EQUIPMENT ANDSYSTEMS ARE CALIBRATED, ADJUSTED AND OPERATEIN ACCORDANCE WITH THESE PLANS ANDSPECIFICATIONS. SEQUENCES OF OPERATION SHALLBE FUNCTIONALLY TESTED TO ENSURE THEYOPERATE IN ACCORDANCE WITH THESE PLANS ANDSPECIFICATIONS WITH STARBUCKS AGENT PRESENT.A COMPLETE REPORT OF TEST PROCEDURES ANDRESULTS SHALL BE PREPARED AND FILED WITHSTARBUCKS ALONG WITH A ONE PAGE NARRATIVEEXPLAINING HOW TO CONTROL THE SYSTEM FOR THESTORE PARTNERS. SEE E-0002 FOR FURTHERREQUIREMENTS.

COMMISSIONINGREQUIREMENTS

Lighting Control SummarySwitch DL Zone Design ID Fixture type Control Timing Control Notes

a X0005 Menuboard/Merch LED Directional Recessed Can 0-10V Dimming TC1b X0012/X0008 Merch LED Track head on monopoint Phase Dimming TC1 (1) Dimming Lock

X0013/X0008 Merch LED Track head on monopoint Phase Dimming TC1 (1) Dimming Lockc X0007 Bar/Zephyr LED Track Phase Dimming TC1 (1) Dimming Lockd X0006 Bar LED Recessed Can 0-10V Dimming TC1 (1) Dimming Locke DL-1B X0012/X0008 Seating LED Track head on monopoint Phase Dimming TC1

DL-1B X0013/X0008 Seating LED Track head on monopoint Phase Dimming TC1f DL-1B X0012/X0008 Community Table LED Track head on monopoint Phase Dimming TC1g DL-1B X0013/X0008 Seating LED Track head on monopoint Phase Dimming TC1h DL-1A X0004 Seating LED Recessed / Directional Can 0-10V Dimming TC1i DL-1A X0004 Seating LED Recessed Can - CONTROLLED NIGHT LIGHT 0-10V Dimming CNLj DL-2A X0004 Seating LED Directional Can 0-10V Dimming TC1k X0003/X0006 RR Vestibule/Condiment Cart LED Recessed Can Timeclock on/off TC1l X0009 Bar / Task LED Tape Shelf Light Timeclock on/off TC1

m X0006 Workroom LED Recessed Can Timeclock on/off TC1n X0002/X0001 LED Workroom Lighting Timeclock on/off TC1

Restroom & Bar Exhaust Fan Timeclock on/off TC1-- Exterior Building Signage Timeclock/PE on/off TC2

EXISTING Exterior Building Lights PE cell on/off TC3X0010/X0011 Restroom Lights Motion Switch, Auto 'On'

o X0005 Artwork LED Direction Recessed Can 0-10V Dimming TC1Timing:TC1 = Program to have lights "on" during occupied hours and "off" during non-business hours. Off hours shall have a max. 1 hour override.TC2 = Program to have lights/signage come "on" at 4:50 a.m. via timeclock and off at dawn via PE cell. Then come "on" at dusk via PE Cell

and "off" at 1:00 a.m. (confirm with Sbux).TC3 = PE Cell Control: Program to turn exterior building lights & Parking lights "ON" at dusk and "off" at dawn with PE Cell.CNL = Program to allow normal TC1 Dimming Control during business hours & remain ON during unoccupied hours.

(1) Dimming Lock: Dimming Control to be locked after initial adjustment - maintain 50fc in Bar area.

ESF17-00829Page 6 of 9

City of KirklandReviewed by J Tumelson02/27/2017

2401 UTAH AVENUE SOUTHSEATTLE, WASHINGTON 98134

(206) 318-1575

SHEET NUMBER:

SHEET TITLE:

SCALE: AS SHOWN

STORE #:

-

PROJECT #:

ISSUE DATE:DESIGN MANAGER:

DRAWN BY:CHECKED BY:

08298-034

01/09/2017

HO

UG

HTO

N P

LAZA

6733

108

th A

ve. N

EK

irkla

nd, W

A 9

8033

PR

OJE

CT

NA

ME

:

PR

OJE

CT

AD

DR

ES

S:

3333

John Park

Chris Rensch

Revision ScheduleRev Date By Description

STARBUCKS COFFEECOMPANY

DESIGNER:

C 2011 STARBUCKS COFFEE COMPANY

R

THESE DRAWINGS AND SPECIFICATIONS ARECONFIDENTIAL AND SHALL REMAIN THE SOLEPROPERTY OF STARBUCKS CORPORATION,

WHICH IS THE OWNER OF THE COPYRIGHT INTHIS WORK. THEY SHALL NOT BE REPRODUCED

(IN WHOLE OR IN PART), SHARED WITH THIRDPARTIES OR USED IN ANY MANNER ON OTHERPROJECTS OR EXTENSIONS TO THIS PROJECTWITHOUT THE PRIOR WRITTEN CONSENT OF

STARBUCKS CORPORATION. THESE DRAWINGSAND SPECIFICATIONS ARE INTENDED TO

EXPRESS DESIGN INTENT FOR APROTOTYPICAL STARBUCKS STORE (WHICH IS

SUBJECT TO CHANGE AT ANYTIME) AND DO NOTREFLECT ACTUAL SITE CONDITIONS. NEITHER

PARTY SHALL HAVE ANY OBLIGATION NORLIABILITY TO THE OTHER (EXCEPT STATED

ABOVE) UNTIL A WRITTEN AGREEMENT IS FULLYEXECUTED BY BOTH PARTIES.

STARBUCKS TEMPLATE VERSION i2014.10.20

LLC

111 AVE. C SUITE 104, SNOHOMISH, WA 98290PH: 360-863-6677

www.renschengineering.comFX: 360-863-3565

0 2' 4' 8'

N E-1103

Yumi RothGloriana Huhta

ROOF POWER PLAN

ROOF POWER PLAN

# POWER KEY NOTES1. EXHAUST FAN: CONNECT TO LCS (SEE DETAIL ON E-6001). FAN SHALL RUN CONTINUOUSLY

DURING OCCUPIED MODE. COORDINATE WITH MECHANICAL.

2. SEE MECHANICAL PLANS FOR SPECIFICATIONS. COORDINATE WITH MECHANICAL

3. DUCT MOUNTED SMOKE DETECTOR. COORDINATE WITH MECHANICAL FOR HVACINTERLOCK SHUT DOWN AND F&I 120V CIRCUIT.

4. FURNISH AND INSTALL WEATHERPROOF, GFI, DUPLEX NEMA 5-20R RECEPTACLE ON ROOFAT UNIT. MOUNT RECEPTACLE ON UNIT IN THE MANUFACTURER'S RECOMMENDEDLOCATION THAT DOES NOT OBSTRUCT ACCESS AND NAMEPLATES.

ESF17-00829Page 7 of 9

City of KirklandReviewed by J Tumelson02/27/2017

2401 UTAH AVENUE SOUTHSEATTLE, WASHINGTON 98134

(206) 318-1575

SHEET NUMBER:

SHEET TITLE:

SCALE: AS SHOWN

STORE #:

-

PROJECT #:

ISSUE DATE:DESIGN MANAGER:

DRAWN BY:CHECKED BY:

08298-034

01/09/2017

HO

UG

HTO

N P

LAZA

6733

108

th A

ve. N

EK

irkla

nd, W

A 9

8033

PR

OJE

CT

NA

ME

:

PR

OJE

CT

AD

DR

ES

S:

3333

John Park

Chris Rensch

Revision ScheduleRev Date By Description

STARBUCKS COFFEECOMPANY

DESIGNER:

C 2011 STARBUCKS COFFEE COMPANY

R

THESE DRAWINGS AND SPECIFICATIONS ARECONFIDENTIAL AND SHALL REMAIN THE SOLEPROPERTY OF STARBUCKS CORPORATION,

WHICH IS THE OWNER OF THE COPYRIGHT INTHIS WORK. THEY SHALL NOT BE REPRODUCED

(IN WHOLE OR IN PART), SHARED WITH THIRDPARTIES OR USED IN ANY MANNER ON OTHERPROJECTS OR EXTENSIONS TO THIS PROJECTWITHOUT THE PRIOR WRITTEN CONSENT OF

STARBUCKS CORPORATION. THESE DRAWINGSAND SPECIFICATIONS ARE INTENDED TO

EXPRESS DESIGN INTENT FOR APROTOTYPICAL STARBUCKS STORE (WHICH IS

SUBJECT TO CHANGE AT ANYTIME) AND DO NOTREFLECT ACTUAL SITE CONDITIONS. NEITHER

PARTY SHALL HAVE ANY OBLIGATION NORLIABILITY TO THE OTHER (EXCEPT STATED

ABOVE) UNTIL A WRITTEN AGREEMENT IS FULLYEXECUTED BY BOTH PARTIES.

STARBUCKS TEMPLATE VERSION i2014.10.20

LLC

111 AVE. C SUITE 104, SNOHOMISH, WA 98290PH: 360-863-6677

www.renschengineering.comFX: 360-863-3565

E-6001

Yumi RothGloriana Huhta

ELECTRICALSCHEDULES

Lighting Schedule Notes:1. Contractor shall coordinate with schedule and starbucks to ensure that all light fixtures in food preparation areas are provided with shatter proof lamps or lenses.2. F&I pendants as needed for track & pendant mounted fixtures (where not provided by manuf. - confirm)

4

E

AREOLEON,T INUCED

RDHERECTOFNGS

O

H ISNOT

HERR

EDULLY

.20

5

UE SOUTHGTON 98134575

8298-03498-034

/09/20172017

6733

108

th A

ve. N

EK

irkla

nd, W

A 9

8033

land

, WA

980

33333

hn Parkark

hris RenschRensch

eduleDescription

COFFEENY

EE COMPANY

R

ECIFICATIONS AREMAIN THE SOS CORPORATIO

THE COPYRIGHTOT BE REPRODU

ARED WITH THIMANNER ON OTHS TO THIS PROJE

TEN CONSENT O THESE DRAWI

RE INTENDED TOTENT FOR AS STORE (WHICHYTIME) AND DODITIONS. NEITH

OBLIGATION NO(EXCEPT STATE

GREEMENT IS FUH PARTIES.

RSION i2014.10

LLC

OMISH, WA 98290

eering.com 360-863-3565

umi RothRothoriana Huhtana Huhta

UTAH AVENULE, WASHING

(206) 318-1

#:

GER:

08

01/

PR

OJE

CT

AD

DR

ES

S:

33

Jo

Ch

Revision ScheBy D

RBUCKS COMPA

011 STARBUCKS COFFE

WINGS AND SPEAL AND SHALL ROF STARBUCKS

HE OWNER OF TTHEY SHALL NOOR IN PART), SHUSED IN ANY M

OR EXTENSIONSHE PRIOR WRITTCORPORATION. CIFICATIONS ARESS DESIGN INT

CAL STARBUCKSCHANGE AT ANYTUAL SITE CONALL HAVE ANY OTO THE OTHER (L A WRITTEN AGCUTED BY BOTH

S TEMPLATE VE

C SUITE 104, SNOHO863-6677w.renschengine

FX:

YuGlo

2401 USEATTL

STORE #:

-

PROJECT #

ISSUE DATE:DESIGN MANA

DRAWN BY:CHECKED BY:

PR

OJE

CT

NA

ME

:

Rev Date

STAR

DESIGNER:

C 20

THESE DRAWCONFIDENTIPROPERTY

WHICH IS THTHIS WORK. T

(IN WHOLE OPARTIES ORPROJECTS OWITHOUT TH

STARBUCKS CAND SPEC

EXPREPROTOTYPIC

SUBJECT TO CREFLECT ACT

PARTY SHALIABILITY T

ABOVE) UNTILEXEC

STARBUCKS

111 AVE. CPH: 360-8

www

mps or lenses.h shatter proof lamare provided withreparation areas confirm)

fixtures in food prded by manuf. - c

sure that all light f(where not provid

starbucks to ensmounted fixtures (

ith schedule andrack & pendant m

dule Notes:hall coordinate ws as needed for tr

Lighting Sched1. Contractor sh2. F&I pendants

ESF17-00829Page 8 of 9

City of KirklandReviewed by J Tumelson02/27/2017

2401 UTAH AVENUE SOUTHSEATTLE, WASHINGTON 98134

(206) 318-1575

SHEET NUMBER:

SHEET TITLE:

SCALE: AS SHOWN

STORE #:

-

PROJECT #:

ISSUE DATE:DESIGN MANAGER:

DRAWN BY:CHECKED BY:

08298-034

01/09/2017

HO

UG

HTO

N P

LAZA

6733

108

th A

ve. N

EK

irkla

nd, W

A 9

8033

PR

OJE

CT

NA

ME

:

PR

OJE

CT

AD

DR

ES

S:

3333

John Park

Chris Rensch

Revision ScheduleRev Date By Description

STARBUCKS COFFEECOMPANY

DESIGNER:

C 2011 STARBUCKS COFFEE COMPANY

R

THESE DRAWINGS AND SPECIFICATIONS ARECONFIDENTIAL AND SHALL REMAIN THE SOLEPROPERTY OF STARBUCKS CORPORATION,

WHICH IS THE OWNER OF THE COPYRIGHT INTHIS WORK. THEY SHALL NOT BE REPRODUCED

(IN WHOLE OR IN PART), SHARED WITH THIRDPARTIES OR USED IN ANY MANNER ON OTHERPROJECTS OR EXTENSIONS TO THIS PROJECTWITHOUT THE PRIOR WRITTEN CONSENT OF

STARBUCKS CORPORATION. THESE DRAWINGSAND SPECIFICATIONS ARE INTENDED TO

EXPRESS DESIGN INTENT FOR APROTOTYPICAL STARBUCKS STORE (WHICH IS

SUBJECT TO CHANGE AT ANYTIME) AND DO NOTREFLECT ACTUAL SITE CONDITIONS. NEITHER

PARTY SHALL HAVE ANY OBLIGATION NORLIABILITY TO THE OTHER (EXCEPT STATED

ABOVE) UNTIL A WRITTEN AGREEMENT IS FULLYEXECUTED BY BOTH PARTIES.

STARBUCKS TEMPLATE VERSION i2014.10.20

LLC

111 AVE. C SUITE 104, SNOHOMISH, WA 98290PH: 360-863-6677

www.renschengineering.comFX: 360-863-3565

Yumi RothOliver Smith

E-6002

ELECTRICAL PANELS &RISER

SERVICE ONE LINE DIAGRAM1

ENUE SOUTHINGTON 981348-1575

S COFFEEANY

OFFEE COMPANY

R

SPECIFICATIONS ARELL REMAIN THE SOLECKS CORPORATION,F THE COPYRIGHT INNOT BE REPRODUCEDSHARED WITH THIRD

Y MANNER ON OTHERNS TO THIS PROJECT

RITTEN CONSENT OFON. THESE DRAWINGSARE INTENDED TOINTENT FOR A

CKS STORE (WHICH ISANYTIME) AND DO NOTONDITIONS. NEITHERY OBLIGATION NOR

ER (EXCEPT STATEDAGREEMENT IS FULLY

OTH PARTIES.

VERSION i2014.10.20

LLC

OHOMISH, WA 98290

ineering.comFX: 360-863-3565

2401 UTAH AVESEATTLE, WASHI

(206) 318

STARBUCKSCOMP

C 2011 STARBUCKS CO

THESE DRAWINGS AND SCONFIDENTIAL AND SHALPROPERTY OF STARBUC

WHICH IS THE OWNER OHIS WORK. THEY SHALL(IN WHOLE OR IN PART),PARTIES OR USED IN ANYPROJECTS OR EXTENSIOWITHOUT THE PRIOR WR

STARBUCKS CORPORATIOAND SPECIFICATIONS

EXPRESS DESIGNPROTOTYPICAL STARBUCUBJECT TO CHANGE AT AREFLECT ACTUAL SITE CO

PARTY SHALL HAVE ANLIABILITY TO THE OTHE

ABOVE) UNTIL A WRITTENEXECUTED BY BO

STARBUCKS TEMPLATE V

111 AVE. C SUITE 104, SNPH: 360-863-6677

www.renschengiF

T

PP

S

PSR

A

ESF17-00829Page 9 of 9

City of KirklandReviewed by J Tumelson02/27/2017