Upload
others
View
103
Download
1
Embed Size (px)
Citation preview
HOW TO CHANGE YOUR SCALEOUT MEDIA
Models: S15T, S15T+, S15C, S15C+, S22, S22+, SC2, SC2+, SC3 & SC3+
Total time required approx. 30-45 minutes
1. Turn off water supply via Inlet valve on 3
valves by pass.
Relieve pressure by opening mains cold water
tap after Scaleout unit.
2. Remove both red clips as pictures right.
3. Remove inlet connector and also connector to
Post Filter.
Be aware there will be water spillage from these
connections.
4. With unit free of inlet and outlet connections,
it should look as picture right?
5. Insert white gripper (supplied) and refix red
clip.
6. Undo head applying pressure anticlockwise to
remove head from bottle.
Extra pressure may be required i.e. rubber or
wooden mallet.
Please DO NOT USE a metal hammer.
7. Remove head complete with internal tube. Be
aware of slight water spillage here.
8. Empty spent media. This can be disposed of
safely with your normal household rubbish.
Rinse out bottle with cold water. Remove central
grey tube from the head and place back in the
bottle. Add red cap (supplied) over the top of the
grey tube. This is to stop new media entering
and causing damage downstream on the
Scaleout.
Gently pour new media into the bottle using a
funnel if possible (not supplied)
9. Clean top of vessel where head ‘o’ ring joins
for seal and apply a small amount of Vaseline to
‘o’ ring and head seal area to help the heads
main ‘o’ ring to seal.
Screw head on to bottle clockwise after carefully
sliding the yellow ‘basket’ over the grey tube.
When you are engaging the first threads of the
head into the bottle, you may feel a slight
resistance. This is normal as it is the grey tube
engaging with the heads internal ‘o’ ring to seal.
10. Reconnect Post Filter after changing post
Filters internal cartridge.
Insert red clip.
11. Reconnect inlet connection.
Insert red clip.
12. Turn on water supply and check for leaks.
Run water for 2 minutes from adjacent mains tap
after Scaleout unit and let unit stand for 15
minutes with no water being used. This allows
the resin to acclimatise to your local water
conditions.
Models SLC and SLC+ only
13. Turn off water supply via Inlet valve on 3
valves by pass.
Relieve pressure by opening mains cold water
tap after Scaleout unit.
14. Disconnect both inlet and outlet hoses to
leave Post Filter attached to the outlet
connector
15. Unscrew head anticlockwise but do not use
Post Filter as leverage.
Remove head complete with internal tube. Be
aware of water spillage from Perspex viewing
bowl here.
16. Empty spent media. This can be disposed of
safely with your normal household rubbish.
Rinse out bottle with cold water. Remove
central grey tube from the head and place back
in the bottle. Add red cap (supplied) over the
top of the grey tube. This is to stop new media
entering and causing damage downstream on
the Scaleout.
Gently pour new media into the bottle using a
funnel if possible (not supplied)
17. Clean top of vessel where head ‘o’ ring joins
for seal and apply a small amount of Vaseline to
‘o’ ring and head seal area to help the heads
main ‘o’ ring to seal.
Screw head on to bottle clockwise after carefully
sliding the white ‘basket’ over the grey tube.
When you are engaging the first threads of the
head into the bottle, you may feel a slight
resistance. Applying Vaseline to both threads
will help here.
18. Change SPF20 cartridge – see separate
instructions
19. Reconnect inlet and outlet flexible hoses.
Important: If fibre washers were originally used,
ensure they are not damaged if reusing. New
washers are enclosed in with the instructions.
Step by step guide to change SPF10 cartridge
A. Turn water supply off to unit. This can be the inlet valve on the bypass set, or better still the
mains stop cock as it is recommended to use this valve once a year to ensure it does not
seize when needed in an emergency.
B. Open a cold mains tap downstream of the Scaleout to relieve the pressure inside the unit.
C. Using the spanner provided, slide it up the filter bowl to engage the notches on the top of
the bowl or the large nut – depending on the model below.
D. Turn the spanner clockwise (to the left (remember ‘lefty loosey, righty tighty’) to undo the
bowl/spanner. It is recommended to hold the housing head to prevent undue stress on
other parts of the system/unit. It might be a very tight connection here but clockwise is the
only way the spanner must be turned to undo this connection.
E. Remove the old cartridge and dispose in your household rubbish.
F. Clean inside of bowl with clean wet cloth.
G. Place new cartridge inside bowl ensuring that the centre female orifice of the cartridge slides
over the main part in the bottom of the bowl.
H. Grease ‘o’ ring on the housing using a food grade grease or Vaseline.
I. Ensure new cartridge fits over male part protruding down in the top of the filter unit head.
J. Tighten bowl/nut to seal.
K. Slowly open inlet valve/mains stop cock and allow water to run for 2-3 minutes.
L. Close mains tap that was previously opened.
M. Check for leaks.
Mark One 2 piece housings
Current 3 piece housing
Monarch Water Ltd, Halesworth Road, Bramfield, Suffolk, IP19 9HP.
Tel 01986 784759. Fax 01986 784769.
www.monarchwater.co.uk www.scaleout.co.uk [email protected]