Revision 1.0 THIS DOCUMENT CONTAINS PROPRIETARY TECHNICAL INFORMATION WHICH IS THE PROPERTY OF SYNOLOGY INCORPORATED AND SHALL NOT BE DISCLOSED TO OTHERS IN WHOLE OR IN PART, REPRODUCED, COPIED, OR USED AS THE BASIS FOR DESIGN, MANUFACTURING, OR SALE OF APPARATUS WITHOUT WRITTEN PERMISSION OF SYNOLOGY INCORPORATED. How to Replace Fan for 2 bay DiskStation

How to Replace Fan for 2 bay DiskStation · 2015-01-09 · How to Replace Fan for 2 bay DiskStation Page 6 of 42 Date: 2014/10/14 Issued by: Hardware Development Group, Synology ®

  • Upload
    others

  • View
    4

  • Download
    0

Embed Size (px)

Citation preview

Page 1: How to Replace Fan for 2 bay DiskStation · 2015-01-09 · How to Replace Fan for 2 bay DiskStation Page 6 of 42 Date: 2014/10/14 Issued by: Hardware Development Group, Synology ®

Revision 1.0

THIS DOCUMENT CONTAINS PROPRIETARY

TECHNICAL INFORMATION WHICH IS THE

PROPERTY OF SYNOLOGY INCORPORATED AND

SHALL NOT BE DISCLOSED TO OTHERS IN

WHOLE OR IN PART, REPRODUCED, COPIED, OR

USED AS THE BASIS FOR DESIGN,

MANUFACTURING, OR SALE OF APPARATUS

WITHOUT WRITTEN PERMISSION OF SYNOLOGY

INCORPORATED.

How to Replace Fan

for 2 bay DiskStation

Page 2: How to Replace Fan for 2 bay DiskStation · 2015-01-09 · How to Replace Fan for 2 bay DiskStation Page 6 of 42 Date: 2014/10/14 Issued by: Hardware Development Group, Synology ®

How to Replace Fan for 2 bay DiskStation

Page 2 of 42 Date: 2014/10/14 Issued by: Hardware Development Group, Synology ® Inc.

Table of Content

1. Introduction ................................................................................................................. 3

1.1 Applied Models & Required Components .......................................................... 3

1.2 Required Tools ................................................................................................... 3

2. Replace for DS214play, DS214, DS213+, DS213, DS212+, DS212 ........................... 4

2.1 Dismantle the defective fan module ................................................................... 4

2.2 Install the replacement fan module .................................................................. 13

3. Replace for DS214se, DS213air, DS213j, DS212j, DX213 ...................................... 21

3.1 Dismantle the enclosure .................................................................................. 21

3.2 Replace the fan module for DS214se, DS213j................................................. 27

3.3 Replace the fan module for DS213air, DS212j, DX213 .................................... 37

3.4 Restore the enclosure ...................................................................................... 41

Revision History

Revision

Number Date of Issue Summary of Change By

v.1.0 2014/10/14 Initial version Dennis Tang

Page 3: How to Replace Fan for 2 bay DiskStation · 2015-01-09 · How to Replace Fan for 2 bay DiskStation Page 6 of 42 Date: 2014/10/14 Issued by: Hardware Development Group, Synology ®

How to Replace Fan for 2 bay DiskStation

Page 3 of 42 Date: 2014/10/14 Issued by: Hardware Development Group, Synology ® Inc.

1. Introduction

This SOP explains about the detailed steps for replacing system fan on Synology’s 2 bay

DiskStation products.

1.1 Applied Models & Required Components

� Fan module of the DiskStation model for replacing:

Required Module Item Code Description Applied Model

Fan 92*92*25_1 13-060901139

3PIN DC12V 2510 W/ 120mm

1800RPM FD129225LL-N(1A3H)

PB_FREE

DS214

DS214play

DS214se

DS213+

DS213air

DS213

DS213j

DS212+

DS212

DS212j

DX213

� Fan 92*92*25_1

Note: For DS214+, refer to the SOP for DS71x series.

Note: All replacement fans are delivered with NO protecting net.

1.2 Required Tools

� Screw Driver “+” Type: Suggested Bit Size PH#2

� Aluminum Foil: 1pc needed for one DS unit (DS214se, DS213air, DS213j, DS212j,

DX213)

Synology P/N: 13-050000010

Description: Conductive Tape (導電膠帶) AL 10*40mm T0.05 CAL-005

� Anti-static / Cotton Gloves

Page 4: How to Replace Fan for 2 bay DiskStation · 2015-01-09 · How to Replace Fan for 2 bay DiskStation Page 6 of 42 Date: 2014/10/14 Issued by: Hardware Development Group, Synology ®

How to Replace Fan for 2 bay DiskStation

Page 4 of 42 Date: 2014/10/14 Issued by: Hardware Development Group, Synology ® Inc.

2. Replace for DS214play, DS214, DS213+, DS213, DS212+, DS212

Note: DS214play is hereunder the common example.

2.1 Dismantle the defective fan module

2.1.1 Remove the front cover. (Fig. 1)

Fig. 1

2.1.2 Remove the both disk trays from the HDD chassis. (Fig. 2)

Fig. 2

Front Cover

Disk Tray HDD Chassis

Page 5: How to Replace Fan for 2 bay DiskStation · 2015-01-09 · How to Replace Fan for 2 bay DiskStation Page 6 of 42 Date: 2014/10/14 Issued by: Hardware Development Group, Synology ®

How to Replace Fan for 2 bay DiskStation

Page 5 of 42 Date: 2014/10/14 Issued by: Hardware Development Group, Synology ® Inc.

2.1.3 The left cover clamps to the enclosure frame with the two (2) tenons on its interior

(Marked by the red rectangle). (Fig. 3)

Fig. 3

Put your four fingers other than the thumb on the enclosure frame. (Fig. 4)

Fig. 4

Front Panel – Right Cover

Tenon

Enclosure Frame

Left Cover Enclosure

Frame

Left Cover

Page 6: How to Replace Fan for 2 bay DiskStation · 2015-01-09 · How to Replace Fan for 2 bay DiskStation Page 6 of 42 Date: 2014/10/14 Issued by: Hardware Development Group, Synology ®

How to Replace Fan for 2 bay DiskStation

Page 6 of 42 Date: 2014/10/14 Issued by: Hardware Development Group, Synology ® Inc.

2.1.4 Put your thumb on the outer edge of the left cover. Then grab the enclosure frame

and push the left cover at the same time to make the two tenons bypassed the

enclosure frame. Separate the left cover and the enclosure frame/right cover. (Fig.

5)

Fig. 5

Fig. 6 & 7 show the status before and after the tenons bypass the enclosure frame.

Fig. 6 – Before Bypassing Fig. 7 – After Bypassing

Left Cover

Enclosure Frame

Left Cover – Interior

Tenon

Left Cover – Interior

Right Cover

Page 7: How to Replace Fan for 2 bay DiskStation · 2015-01-09 · How to Replace Fan for 2 bay DiskStation Page 6 of 42 Date: 2014/10/14 Issued by: Hardware Development Group, Synology ®

How to Replace Fan for 2 bay DiskStation

Page 7 of 42 Date: 2014/10/14 Issued by: Hardware Development Group, Synology ® Inc.

Fig. 8 & 9 show the status before and after the left cover and the enclosure

frame/right cover are separated.

Fig. 8 – Before Separating Fig. 9 – After Separating

2.1.5 Put the right cover side down. Then remove the left cover from the HDD chassis.

(Fig. 10)

Fig. 10

HDD Chassis

Left Cover – Bottom

Right Cover

Left Cover - Top

Right Cover - Top

Front Panel

Page 8: How to Replace Fan for 2 bay DiskStation · 2015-01-09 · How to Replace Fan for 2 bay DiskStation Page 6 of 42 Date: 2014/10/14 Issued by: Hardware Development Group, Synology ®

How to Replace Fan for 2 bay DiskStation

Page 8 of 42 Date: 2014/10/14 Issued by: Hardware Development Group, Synology ® Inc.

Fig. 11 shows the status after the left cover and the HDD chassis are separated.

Fig. 11

2.1.6 Release the two (2) screws on the enclosure frame (Marked by the red circles) then

remove the plastic bracket which joins the defectivre fan and the HDD chassis. (Fig.

12)

Fig. 12

Left Cover - Interior

HDD Chassis

Right Cover

Rear Side Plastic Bracket

Plastic Bracket

Defective Fan

HDD Chassis

Right Cover

Rear Panel - Interior

Page 9: How to Replace Fan for 2 bay DiskStation · 2015-01-09 · How to Replace Fan for 2 bay DiskStation Page 6 of 42 Date: 2014/10/14 Issued by: Hardware Development Group, Synology ®

How to Replace Fan for 2 bay DiskStation

Page 9 of 42 Date: 2014/10/14 Issued by: Hardware Development Group, Synology ® Inc.

2.1.7 Release the four (4) screws on the enclosure frame (Marked by the red circles).

(Fig. 13 & 14)

Fig. 13 – Right Side Fig. 14 – Left Side

2.1.8 Then remove the HDD chassis from the enclosure. (Fig. 15)

Fig. 15

Rear Panel – Bottom Side

Rear Panel – Bottom Side

HDD Chassis HDD Chassis

Right Cover HDD Chassis

Page 10: How to Replace Fan for 2 bay DiskStation · 2015-01-09 · How to Replace Fan for 2 bay DiskStation Page 6 of 42 Date: 2014/10/14 Issued by: Hardware Development Group, Synology ®

How to Replace Fan for 2 bay DiskStation

Page 10 of 42 Date: 2014/10/14 Issued by: Hardware Development Group, Synology ® Inc.

Fig. 16 shows the status after the HDD chassis is removed from the enclosure.

Fig. 16

2.1.9 Remove the aluminum foil (Marked by the red rectangle) from the interior of the

rear panel. (Fig. 17)

Fig. 17

Right Cover

HDD Chassis

Aluminum Foil Rear Panel -

Interior Defective

Fan

Page 11: How to Replace Fan for 2 bay DiskStation · 2015-01-09 · How to Replace Fan for 2 bay DiskStation Page 6 of 42 Date: 2014/10/14 Issued by: Hardware Development Group, Synology ®

How to Replace Fan for 2 bay DiskStation

Page 11 of 42 Date: 2014/10/14 Issued by: Hardware Development Group, Synology ® Inc.

2.1.10 Unplug the fan cable connector (Marked by the red rectangle) which attaches to

the motherboard. (Fig. 18)

Fig. 18

2.1.11 Release the four (4) screws on the fan panel (Marked by the red circles) which fix

the defective fan. (Fig. 19)

Fig. 19

Rear Panel

Defective Fan

Fan Cable Connector

Motherboard Board

Defective Fan

Rear Panel - Interior

Page 12: How to Replace Fan for 2 bay DiskStation · 2015-01-09 · How to Replace Fan for 2 bay DiskStation Page 6 of 42 Date: 2014/10/14 Issued by: Hardware Development Group, Synology ®

How to Replace Fan for 2 bay DiskStation

Page 12 of 42 Date: 2014/10/14 Issued by: Hardware Development Group, Synology ® Inc.

2.1.12 Remove the protecting net of the defective fan from the rear panel. (Fig. 20)

Fig. 20

2.1.13 Remove the defective fan module from the interior of the rear panel. (Fig. 21)

Fig. 21

Defective Fan

Rear Panel - Interior

Protecting Net

Rear Panel

Page 13: How to Replace Fan for 2 bay DiskStation · 2015-01-09 · How to Replace Fan for 2 bay DiskStation Page 6 of 42 Date: 2014/10/14 Issued by: Hardware Development Group, Synology ®

How to Replace Fan for 2 bay DiskStation

Page 13 of 42 Date: 2014/10/14 Issued by: Hardware Development Group, Synology ® Inc.

2.2 Install the replacement fan module

2.2.1 Put the replacement fan module to the same location of the defective one on the

interior of the rear panel. (Fig. 22)

Fig. 22

2.2.2 Restore the protecting net to its original location on the rear panel. (Fig. 23)

Fig. 23

Replcement Fan

Rear Panel - Interior

Protecting Net

Rear Panel

Page 14: How to Replace Fan for 2 bay DiskStation · 2015-01-09 · How to Replace Fan for 2 bay DiskStation Page 6 of 42 Date: 2014/10/14 Issued by: Hardware Development Group, Synology ®

How to Replace Fan for 2 bay DiskStation

Page 14 of 42 Date: 2014/10/14 Issued by: Hardware Development Group, Synology ® Inc.

2.2.3 Fix the four (4) screws on the fan panel (Marked by the red circles) to secure the

replacement fan. (Fig. 24)

Fig. 24

2.2.4 Plug the fan cable connector (Marked by the red rectangle) to the same location as

of the defective fan on the motherboard. (Fig. 25)

Fig. 25

Rear Panel

Replacement Fan

Fan Cable Connector

Motherboard Board

Replacement Fan

Rear Panel - Interior

Page 15: How to Replace Fan for 2 bay DiskStation · 2015-01-09 · How to Replace Fan for 2 bay DiskStation Page 6 of 42 Date: 2014/10/14 Issued by: Hardware Development Group, Synology ®

How to Replace Fan for 2 bay DiskStation

Page 15 of 42 Date: 2014/10/14 Issued by: Hardware Development Group, Synology ® Inc.

2.2.5 Replace the aluminum foil with a new one on the same locations. (Fig. 26)

Fig. 26

2.2.6 To restore the HDD chassis into the enclosure, there are two (2) locations as follow

for joining the two sides (Fig. 27):

Motherboard Side Enclosure Side

#1 PCI Express connector #2 Bonding finger of the HDD backplane

Fig. 27

Motherboard

HDD Chassis

HDD Backplane

#2

#1

Aluminum Foil Rear Panel -

Interior Replacement

Fan

Page 16: How to Replace Fan for 2 bay DiskStation · 2015-01-09 · How to Replace Fan for 2 bay DiskStation Page 6 of 42 Date: 2014/10/14 Issued by: Hardware Development Group, Synology ®

How to Replace Fan for 2 bay DiskStation

Page 16 of 42 Date: 2014/10/14 Issued by: Hardware Development Group, Synology ® Inc.

Restore the HDD chassis to its original location on the enclosure. Then join them

together with #2 inserted into #1 properly (Marked by the red rectangle). (Fig. 28)

Fig. 28

2.2.7 Then fix the four (4) screws on the enclosure frame (Marked by the red circles) to

secure the HDD chassis. (Fig. 29 & 30)

Fig. 29 – Right Side Fig. 30 – Left Side

Right Cover HDD Chassis

Rear Panel – Bottom Side

Rear Panel – Bottom Side

HDD Chassis HDD Chassis

Page 17: How to Replace Fan for 2 bay DiskStation · 2015-01-09 · How to Replace Fan for 2 bay DiskStation Page 6 of 42 Date: 2014/10/14 Issued by: Hardware Development Group, Synology ®

How to Replace Fan for 2 bay DiskStation

Page 17 of 42 Date: 2014/10/14 Issued by: Hardware Development Group, Synology ® Inc.

2.2.8 Restore the plastic bracket to join the replacement fan and the HDD chassis. Then

fix the two (2) screws (Marked by the red circles). (Fig. 31)

Fig. 31

2.2.9 Restore the left cover to its original location covering the HDD chassis. (Fig. 32)

Fig. 32

目前無法顯示此圖像。

Plastic Bracket

Replacemente Fan

HDD Chassis

Right Cover

Rear Panel - Interior

HDD Chassis

Left Cover - Top

Right Cover - Top

Front Panel

Page 18: How to Replace Fan for 2 bay DiskStation · 2015-01-09 · How to Replace Fan for 2 bay DiskStation Page 6 of 42 Date: 2014/10/14 Issued by: Hardware Development Group, Synology ®

How to Replace Fan for 2 bay DiskStation

Page 18 of 42 Date: 2014/10/14 Issued by: Hardware Development Group, Synology ® Inc.

2.2.10 Hold up the right cover then push the left cover to join together them until a click is

heard. Make sure the both covers are joined properly. (Fig. 33)

Fig. 33

Fig. 34 shows the status after the left cover and the enclosure frame are joined

together.

Fig. 34

Left Cover

Right Cover

Front Panel – Right Cover

Tenon

Enclosure Frame

Left Cover

Page 19: How to Replace Fan for 2 bay DiskStation · 2015-01-09 · How to Replace Fan for 2 bay DiskStation Page 6 of 42 Date: 2014/10/14 Issued by: Hardware Development Group, Synology ®

How to Replace Fan for 2 bay DiskStation

Page 19 of 42 Date: 2014/10/14 Issued by: Hardware Development Group, Synology ® Inc.

Fig. 35 & 36 show the status before and after the tenons clamp to the enclosure

frame.

Fig. 35 – Before Joining Fig. 36 – After Joining

2.2.11 Restore the both disk trays into the HDD chassis. (Fig. 37)

Fig. 37

Left Cover – Interior

Tenon

Left Cover – Interior

Disk Tray HDD Chassis

Page 20: How to Replace Fan for 2 bay DiskStation · 2015-01-09 · How to Replace Fan for 2 bay DiskStation Page 6 of 42 Date: 2014/10/14 Issued by: Hardware Development Group, Synology ®

How to Replace Fan for 2 bay DiskStation

Page 20 of 42 Date: 2014/10/14 Issued by: Hardware Development Group, Synology ® Inc.

2.2.12 Restore the front cover. (Fig. 38)

Fig. 38

2.3 The replacing task is completed.

Front Cover

Page 21: How to Replace Fan for 2 bay DiskStation · 2015-01-09 · How to Replace Fan for 2 bay DiskStation Page 6 of 42 Date: 2014/10/14 Issued by: Hardware Development Group, Synology ®

How to Replace Fan for 2 bay DiskStation

Page 21 of 42 Date: 2014/10/14 Issued by: Hardware Development Group, Synology ® Inc.

3. Replace for DS214se, DS213air, DS213j, DS212j, DX213

Note: DS214se is hereunder the common example.

3.1 Dismantle the enclosure

3.1.1 Release the two (2) screws (Marked by the red circles) on the rear side of the right

cover. (Fig. 39)

Fig. 39

Rear Panel

Right Cover

Page 22: How to Replace Fan for 2 bay DiskStation · 2015-01-09 · How to Replace Fan for 2 bay DiskStation Page 6 of 42 Date: 2014/10/14 Issued by: Hardware Development Group, Synology ®

How to Replace Fan for 2 bay DiskStation

Page 22 of 42 Date: 2014/10/14 Issued by: Hardware Development Group, Synology ® Inc.

3.1.2 Use your both thumbs to push the left cover (With the footpad on the right cover

bottom to be the fulcrum) to separate it and the right cover. (Fig. 40 & 41)

Fig. 40 – Before Separating

Fig. 41 – After Separating

Right Cover

Rear Panel

Left Cover

Right Cover

Left Cover

Footpad

Right Cover

Page 23: How to Replace Fan for 2 bay DiskStation · 2015-01-09 · How to Replace Fan for 2 bay DiskStation Page 6 of 42 Date: 2014/10/14 Issued by: Hardware Development Group, Synology ®

How to Replace Fan for 2 bay DiskStation

Page 23 of 42 Date: 2014/10/14 Issued by: Hardware Development Group, Synology ® Inc.

3.1.3 Remove the left cover from the HDD chassis. (Fig. 42)

Fig. 42

Fig. 43 shows the status after the left cover and the HDD chassis are separated.

Fig. 43

HDD Chassis

HDD Chassis

Right Cover

Rear Side

Left Cover

Right Cover

Rear Panel

Left Cover

Page 24: How to Replace Fan for 2 bay DiskStation · 2015-01-09 · How to Replace Fan for 2 bay DiskStation Page 6 of 42 Date: 2014/10/14 Issued by: Hardware Development Group, Synology ®

How to Replace Fan for 2 bay DiskStation

Page 24 of 42 Date: 2014/10/14 Issued by: Hardware Development Group, Synology ® Inc.

3.1.4 Unplug the fan cable connector with the aluminum foil (Marked by the red rectangle)

peeled off. (Fig. 44)

Fig. 44

Fig. 45 shows the status after the above-mentioned is completed.

Fig. 45

Fan Cable Connector

Right Cover

Defective Fan

Aluminum Foil

Rear Panel - Interior

Right Cover

HDD Chassis

Fan Cable Connector

Aluminum Foil

Page 25: How to Replace Fan for 2 bay DiskStation · 2015-01-09 · How to Replace Fan for 2 bay DiskStation Page 6 of 42 Date: 2014/10/14 Issued by: Hardware Development Group, Synology ®

How to Replace Fan for 2 bay DiskStation

Page 25 of 42 Date: 2014/10/14 Issued by: Hardware Development Group, Synology ® Inc.

3.1.5 Release the four (4) screws (Marked by the red circles). (Fig. 46)

Fig. 46

3.1.6 Then remove the HDD chassis from the right cover. Note that at this moment on its

bottom side there is a power button cable to connect with the power button board

(Marked by the read rectangle). (Fig. 47)

Fig. 47

Right Cover

HDD Chassis

HDD Chassis

Defective Fan

Power Button Board

Motherboard

Power Button Cable

Page 26: How to Replace Fan for 2 bay DiskStation · 2015-01-09 · How to Replace Fan for 2 bay DiskStation Page 6 of 42 Date: 2014/10/14 Issued by: Hardware Development Group, Synology ®

How to Replace Fan for 2 bay DiskStation

Page 26 of 42 Date: 2014/10/14 Issued by: Hardware Development Group, Synology ® Inc.

3.1.7 Flip up the HDD chassis up side down (With the motherboard faces upwards).

Remove the tape then unplug the power button cable connector (Marked by the red

rectangle) which attaches to the motherboard. HDD chassis can be removed from

the right cover. (Fig. 48)

Fig. 48

Fig. 49 shows the status after the HDD chassis is removed from the right cover.

Fig. 49

Right Cover

HDD Chassis

Right Cover - Interior

Power Button Board

Motherboard

Power Button Cable

Tape

HDD Chassis

Page 27: How to Replace Fan for 2 bay DiskStation · 2015-01-09 · How to Replace Fan for 2 bay DiskStation Page 6 of 42 Date: 2014/10/14 Issued by: Hardware Development Group, Synology ®

How to Replace Fan for 2 bay DiskStation

Page 27 of 42 Date: 2014/10/14 Issued by: Hardware Development Group, Synology ® Inc.

3.2 Replace the fan module for DS214se, DS213j

3.2.1 Remove the four (4) rubber rivet locks (Marked by the red circles) which fix the

defective fan on the interior of the rear panel. (Fig. 50, 51 and 52)

Fig. 50 – HDD Chassis Side Fig. 51 – Motherboard Side

Fig. 52

Motherboard

Rubber Rivet Lock

Defective Fan

HDD Chassis

Defective Fan

Defective Fan

Motherboard

Page 28: How to Replace Fan for 2 bay DiskStation · 2015-01-09 · How to Replace Fan for 2 bay DiskStation Page 6 of 42 Date: 2014/10/14 Issued by: Hardware Development Group, Synology ®

How to Replace Fan for 2 bay DiskStation

Page 28 of 42 Date: 2014/10/14 Issued by: Hardware Development Group, Synology ® Inc.

3.2.2 Moving the defective fan away from the fan protecting net, the pillars and the rubber

rivets (Marked by the red circles) can then be seen. (Fig. 53)

Fig. 53

3.2.3 Starting from the one most nearby the fan cable (Marked by the red circle), push

the pillar outwards on its top to release the rubber rivet which fixes the protecting

net on the interior of the rear panel. (Fig. 54)

Fig. 54

Rubber Rivet

Defective Fan

HDD Chassis

Defective Fan

Protecting Net

Pillar

Protecting Net

Page 29: How to Replace Fan for 2 bay DiskStation · 2015-01-09 · How to Replace Fan for 2 bay DiskStation Page 6 of 42 Date: 2014/10/14 Issued by: Hardware Development Group, Synology ®

How to Replace Fan for 2 bay DiskStation

Page 29 of 42 Date: 2014/10/14 Issued by: Hardware Development Group, Synology ® Inc.

Fig. 55 shows the status after the rubber rivet is released. Repeat the same for the

other three sets of pilliar and rubber rivet.

Fig. 55

3.2.4 Then remove the fan protecting net from the rear panel. (Fig. 56)

Fig. 56

Protecting Net

Rear Panel

Protecting Net

Rubber Rivet

Pillar

Page 30: How to Replace Fan for 2 bay DiskStation · 2015-01-09 · How to Replace Fan for 2 bay DiskStation Page 6 of 42 Date: 2014/10/14 Issued by: Hardware Development Group, Synology ®

How to Replace Fan for 2 bay DiskStation

Page 30 of 42 Date: 2014/10/14 Issued by: Hardware Development Group, Synology ® Inc.

3.2.5 Remove the defective fan module from the interior of the rear panel. (Fig. 57)

Fig. 57

3.2.6 Insert the replacement fan module to the same location of the defective one on the

interior of the rear panel. (Fig. 58)

Fig. 58

Defective Fan

Rear Panel

Replacement Fan

Rear Panel

Page 31: How to Replace Fan for 2 bay DiskStation · 2015-01-09 · How to Replace Fan for 2 bay DiskStation Page 6 of 42 Date: 2014/10/14 Issued by: Hardware Development Group, Synology ®

How to Replace Fan for 2 bay DiskStation

Page 31 of 42 Date: 2014/10/14 Issued by: Hardware Development Group, Synology ® Inc.

3.2.7 Restore the fan protecting net to its original location on the rear panel. (Fig. 59)

Fig. 59

3.2.8 Fix the four (4) rubber rivets on the pillars to secure the fan protecting net. (Fig. 60)

Fig. 60

Protecting Net

Rear Panel

Protecting Net

Rubber Rivet

Pillar

Page 32: How to Replace Fan for 2 bay DiskStation · 2015-01-09 · How to Replace Fan for 2 bay DiskStation Page 6 of 42 Date: 2014/10/14 Issued by: Hardware Development Group, Synology ®

How to Replace Fan for 2 bay DiskStation

Page 32 of 42 Date: 2014/10/14 Issued by: Hardware Development Group, Synology ® Inc.

3.2.9 Then press the replacement fan outwards with its four (4) holes inserted by the

pillars on the fan protecting net (Marked by the red circles). (Fig. 61)

Fig. 61

3.2.10 Fix the four (4) rubber rivet locks (Marked by the red circles) to secure the

replacement fan on the interior of the rear panel. (Fig. 62, 63 and 64)

Fig. 62 – HDD Chassis Side Fig. 63 – Motherboard Side

HDD Chassis

Replacement Fan

Protecting Net

HDD Chassis

Defective Fan

Defective Fan

Motherboard

Page 33: How to Replace Fan for 2 bay DiskStation · 2015-01-09 · How to Replace Fan for 2 bay DiskStation Page 6 of 42 Date: 2014/10/14 Issued by: Hardware Development Group, Synology ®

How to Replace Fan for 2 bay DiskStation

Page 33 of 42 Date: 2014/10/14 Issued by: Hardware Development Group, Synology ® Inc.

Fig. 64

3.2.11 Plug back the power button cable connector (Marked by the red rectangle) to its

original location on the motherboard board. (Fig. 65) Then paste a new tape to

secure the power button cable on the HDD chassis.

Fig. 65

Motherboard

Rubber Rivet Lock

Replacement Fan

Right Cover - Interior

Power Button Board

Motherboard

Power Button Cable

Tape

HDD Chassis

Page 34: How to Replace Fan for 2 bay DiskStation · 2015-01-09 · How to Replace Fan for 2 bay DiskStation Page 6 of 42 Date: 2014/10/14 Issued by: Hardware Development Group, Synology ®

How to Replace Fan for 2 bay DiskStation

Page 34 of 42 Date: 2014/10/14 Issued by: Hardware Development Group, Synology ® Inc.

3.2.12 Restore the HDD chassis to its original location on the interior of the right cover.

Note that the two hooks on the interior of the right cover should rightly insert into

the correspondent holes on the rear panel (Marked by the red circles). (Fig. 66 &

67)

Fig. 66

Fig. 67

Right Cover

HDD Chassis

Fan

Rear Panel - Interior

Right Cover - Interior

Right Cover - Interior

Rear Panel - Interior

Hook

Hole

Hook

Hole

Page 35: How to Replace Fan for 2 bay DiskStation · 2015-01-09 · How to Replace Fan for 2 bay DiskStation Page 6 of 42 Date: 2014/10/14 Issued by: Hardware Development Group, Synology ®

How to Replace Fan for 2 bay DiskStation

Page 35 of 42 Date: 2014/10/14 Issued by: Hardware Development Group, Synology ® Inc.

Fig. 68 shows the status after the hooks insert the holes.

Fig. 68

3.2.13 Fix the four (4) screws (Marked by the red circles) to secure the HDD chassis.

(Fig. 69)

Fig. 69

HDD Chassis

Fan

Replacement Fan

Rear Panel

Page 36: How to Replace Fan for 2 bay DiskStation · 2015-01-09 · How to Replace Fan for 2 bay DiskStation Page 6 of 42 Date: 2014/10/14 Issued by: Hardware Development Group, Synology ®

How to Replace Fan for 2 bay DiskStation

Page 36 of 42 Date: 2014/10/14 Issued by: Hardware Development Group, Synology ® Inc.

3.2.14 Plug back the fan cable connector to its original location on the motherboard. Then

replace the aluminum foil with a new one pasted on the same location. (Fig. 70)

Fig. 70

Fan Cable Connector

Right Cover

Replacement Fan

Aluminum Foil

Rear Panel - Interior

Page 37: How to Replace Fan for 2 bay DiskStation · 2015-01-09 · How to Replace Fan for 2 bay DiskStation Page 6 of 42 Date: 2014/10/14 Issued by: Hardware Development Group, Synology ®

How to Replace Fan for 2 bay DiskStation

Page 37 of 42 Date: 2014/10/14 Issued by: Hardware Development Group, Synology ® Inc.

3.3 Replace the fan module for DS213air, DS212j, DX213

3.3.1 Release the four (4) screws on the protecting net (Marked by the red circles) which

fix the defective fan. (Fig. 71)

Fig. 71

3.3.2 Remove the protecting net of the defective fan from the rear panel. (Fig. 72)

Fig. 72

Defective Fan

Protecting Net Rear Panel

Rear Panel

Right Cover

Page 38: How to Replace Fan for 2 bay DiskStation · 2015-01-09 · How to Replace Fan for 2 bay DiskStation Page 6 of 42 Date: 2014/10/14 Issued by: Hardware Development Group, Synology ®

How to Replace Fan for 2 bay DiskStation

Page 38 of 42 Date: 2014/10/14 Issued by: Hardware Development Group, Synology ® Inc.

3.3.3 Remove the defective fan module from the interior of the rear panel. (Fig. 73)

Fig. 73

3.3.4 Put the replacement fan module to the same location as of the defective one on the

interior of the rear panel. (Fig. 74)

Fig. 74

Defective Fan

Rear Panel

Replacement Fan

Rear Panel

Page 39: How to Replace Fan for 2 bay DiskStation · 2015-01-09 · How to Replace Fan for 2 bay DiskStation Page 6 of 42 Date: 2014/10/14 Issued by: Hardware Development Group, Synology ®

How to Replace Fan for 2 bay DiskStation

Page 39 of 42 Date: 2014/10/14 Issued by: Hardware Development Group, Synology ® Inc.

3.3.5 Restore the protecting net to its original location on the rear panel. (Fig. 75)

Fig. 75

3.3.6 Fix the four (4) screws on the protecting net (Marked by the red circles) to secure

the replacement fan. (Fig. 76)

Fig. 76

Protecting Net Rear Panel

Replacement Fan

Rear Panel

Right Cover

Page 40: How to Replace Fan for 2 bay DiskStation · 2015-01-09 · How to Replace Fan for 2 bay DiskStation Page 6 of 42 Date: 2014/10/14 Issued by: Hardware Development Group, Synology ®

How to Replace Fan for 2 bay DiskStation

Page 40 of 42 Date: 2014/10/14 Issued by: Hardware Development Group, Synology ® Inc.

3.3.7 Plug back the fan cable connector to its original location on the motherboard. Then

replace the aluminum foil with a new one pasted on the same location. (Fig. 77)

Fig. 77

Fan Cable Connector

Right Cover

Replacement Fan

Aluminum Foil

Rear Panel - Interior

Page 41: How to Replace Fan for 2 bay DiskStation · 2015-01-09 · How to Replace Fan for 2 bay DiskStation Page 6 of 42 Date: 2014/10/14 Issued by: Hardware Development Group, Synology ®

How to Replace Fan for 2 bay DiskStation

Page 41 of 42 Date: 2014/10/14 Issued by: Hardware Development Group, Synology ® Inc.

3.4 Restore the enclosure

3.4.1 Restore the left cover to its original location covering the HDD chassis. (Fig. 78 &

79)

Fig. 78

Fig. 79

HDD Chassis

Left Cover

Right Cover

Rear Panel

Right Cover

Left Cover

Page 42: How to Replace Fan for 2 bay DiskStation · 2015-01-09 · How to Replace Fan for 2 bay DiskStation Page 6 of 42 Date: 2014/10/14 Issued by: Hardware Development Group, Synology ®

How to Replace Fan for 2 bay DiskStation

Page 42 of 42 Date: 2014/10/14 Issued by: Hardware Development Group, Synology ® Inc.

3.4.2 Join the left and right covers properly. (Fig. 80)

Fig. 80

3.5 The replacing task is completed.

Right Cover

Rear Panel

Left Cover

Footpad

Right Cover