Weir Reticle Haze Detection and Monitor
What, Why and How to control reticle haze issues
http://www.TEAsystems.com - 2Yield Enhancement thru ModelingTEA SystemsTEA Systems
Sections
Reticle Haze Concepts Base Method of Weir Haze Detection Weir PW Characterization Weir DM macro setup of Weir PW method Weir DMA automation of input & output data
http://www.TEAsystems.com - 3Yield Enhancement thru ModelingTEA SystemsTEA Systems
Reticle Haze Detection with Weir PW & Weir DMA
Haze formation on reticle continues to be a significant problem for the semiconductor industry.
Haze can be formed on the outside pellicle and on the quartz back side of the reticle.
Major component of the haze is known to be aluminum sulfate that comes from the reticle cleaning process and Deep Ultra Violet interactions with residue.
The reticle materials, the exposure wavelength, roughness of photomask and this haze will affect the resolution and process latitude.
http://www.TEAsystems.com - 4Yield Enhancement thru ModelingTEA SystemsTEA Systems
Reticle Haze Sources
Mask making materials Process residues Reticle container Fab or Scanner environment
http://www.TEAsystems.com - 5Yield Enhancement thru ModelingTEA SystemsTEA Systems
Issues for reticle cleaning
- for DUV lithography Phase and transmittance change Surface contamination
- for VUV lithography Phase and transmittance change Surface contamination ESD
- for EUV lithography Reflectance change Affect of debris?
http://www.TEAsystems.com - 6Yield Enhancement thru ModelingTEA SystemsTEA Systems
Mechanism for the formation of ammonium sulfate haze
http://www.TEAsystems.com - 7Yield Enhancement thru ModelingTEA SystemsTEA Systems
Reticle Haze Influence Transmittance Reduction
• Transmittance reduction caused variations in the CD and DOF values.
• Aberrations will increase:• Since the reticle is an element of the scanner optical train
• Process Window size will decrease and shift center
http://www.TEAsystems.com - 8Yield Enhancement thru ModelingTEA SystemsTEA Systems
Reticle Haze Influence Transmittance Reduction
CD Increase with transmittance loss for a 90nm A.P.S.M.
http://www.TEAsystems.com - 9Yield Enhancement thru ModelingTEA SystemsTEA Systems
Reticle Haze Influences Dose Change
• Expose energy change with transmittance loss for different reticle.
• Backside glass haze can effect overall mask transmission and thus can cause a dose shift on the wafer . A dose shift can be serious because most of low k1 process run with a very small process window and cause serious yield issue.
http://www.TEAsystems.com - 10Yield Enhancement thru ModelingTEA SystemsTEA Systems
Reticle Haze Influences Throughput
Throughput will decrease due to an increase dose required to make same line width. change with transmittance loss for different reticles.
http://www.TEAsystems.com - 11Yield Enhancement thru ModelingTEA SystemsTEA Systems
Sources of CD variation across the wafer
Primary disturbances causing CD Uniformity (CDU) variations grouped upon their sources.
Reticle transmission loss directly influences the effective dose Indirectly increases aberrations in the optical train that result in ACLV CD
Variation increase
Reticle Scanner Track & Process
Effective Focus
Wafer flatness
Device topography
Substrate
BARC coat
Resist Film coat
PEB Temp & Time
Develop
Exposure Dose
Slit Uniformity
Focus SetUp
Chuck Flatness
Up-Down Scan
Flatness
CD’s
Transmission
CDUEffective Dose
Scan Linearity
http://www.TEAsystems.com
Monitoring the process for Reticle Haze
Haze is formed around the pellicle, on the quartz side of the mask and on the chrome side of the mask.
http://www.TEAsystems.com - 13Yield Enhancement thru ModelingTEA SystemsTEA Systems
Haze Appearance Haze influence on the image can be symmetric or anti-symmetric:
Radial Process induced Exposure enhanced
Across-Reticle Reticle Cleaning
Scattered and random Equipment sourced
Testing for Haze Requires multiple points on field Examine
relative CD uniformity DoF Optimum and IsoFocal Dose Dose Uniformity
Reticle Haze
Clean reticle
Process Induced
Cleaning Residue
Cleaning residue & process
http://www.TEAsystems.com - 14Yield Enhancement thru ModelingTEA SystemsTEA Systems
Method of Reticle Haze Monitor
Weir PW Weir PW Characterize Dose Uniformity
Determine Normal Process Window levels for multiple points on the field
Setup Weir DMWeir DM Macro to duplicate Weir PW analysis
one-step processing for the wafer fab.
Setup online trend charts for variables
Automate data gathering with Weir DMAWeir DMA interface to factory control
Automatically output critical process variables to factory-control system
http://www.TEAsystems.com
Weir PW Dose Uniformity Setup for Initial Characterization
Setup Focus-Dose or Dose Matrix Derive base-response of process
http://www.TEAsystems.com - 16Yield Enhancement thru ModelingTEA SystemsTEA Systems
Bossung curve analysis anatomy A = Isofocal Dose
Dose at which feature size is independent of Focus
B = Locus of Best Focus “Best Focus” is located at the
maxima or minima of each dose curve
The greater the curvature, the greater will be the aberrations of the system
UCL/LCL Upper and Lower Control
Limits for the process EL
Exposure Latitude or the dose range over which the feature size lies between the UCL and LCL
DoF Depth of Focus or the focus
range over which the feature size lies between the UCL and LCL
Foc
us
Res
pon
se A
nal
ysis
Foc
us
Res
pon
se A
nal
ysis
Fea
ture
Siz
e
Focus
A
One curve for each dose
B
UCL
LCLDoF
EL
Curve “B” is highly sensitive to lens aberrations
Reticle haze directly influences the aberrations of the tool.
http://www.TEAsystems.com - 17Yield Enhancement thru ModelingTEA SystemsTEA Systems
Weir Dose ReportIsoFocal Dose: Variable Site Dose (mj/cm^2)Feature
BCDv (nm) 1.0000 23.1900 73.8730BCDh (nm) 1.0000 23.8300 56.2230BCDv (nm) 2.0000 23.2200 75.8150BCDh (nm) 2.0000 22.8000 68.5990BCDv (nm) 3.0000 23.3000 75.0460BCDh (nm) 3.0000 23.0700 65.2500BCDv (nm) 4.0000 23.3200 75.0490BCDh (nm) 4.0000 23.8300 56.6960BCDv (nm) 5.0000 23.2300 78.0360BCDh (nm) 5.0000 23.0300 67.1220BCDv (nm) 6.0000 23.8600 70.4050BCDh (nm) 6.0000 23.3200 63.5040
Summary of Dose Response for Max Dose Latitude by SiteBest Best Dose Dose
Feature Site Dose Focus Latitude %LatitudeBCDv (nm) 1.0000 35.0000 -0.0270 1.9210 4.3000BCDh (nm) 1.0000 28.4000 -0.0290 1.9210 4.3000BCDv (nm) 2.0000 31.0000 -0.0310 1.9210 4.3000BCDh (nm) 2.0000 28.5000 -0.0510 1.9210 4.3000BCDv (nm) 3.0000 28.6000 -0.0470 1.9210 4.3000BCDh (nm) 3.0000 27.5000 -0.0480 1.9210 4.3000BCDv (nm) 4.0000 28.3000 -0.0530 1.9210 4.3000
SummaryVariable DoseMean DoseRangeFeatureMeanFeatureRangeBCDh (nm) 22.5000 3.4000 69.9360 35.2920BCDv (nm) 22.5000 22.7000 80.9910 210.6440
PROCESS 22.5000 22.7000
These variables will be gathered by Weir DM & Weir DMA
http://www.TEAsystems.com - 18Yield Enhancement thru ModelingTEA SystemsTEA Systems
Dose curves calculated at best focus
Dos
e R
esp
onse
An
alys
isD
ose
Res
pon
se A
nal
ysis
EL
Upper Blue Curve
Linear Dose curve that reflects the resist’s true response.
Exposure Latitude (EL) can now be evaluated.
Point-spread at each dose is the result of reticle feature size variance.
Lower Red Curve
Plotted Best Focus for each site.
A discontinuity occurs with this data when the IsoFocal point is crossed.
http://www.TEAsystems.com - 19Yield Enhancement thru ModelingTEA SystemsTEA Systems
Isofocal Analysis
Dos
e R
esp
onse
An
alys
isD
ose
Res
pon
se A
nal
ysis
Isofocal Analysis: All-sites on field, BCD features Vertical (black) and Horizontal (red)
1) Calculate IsoFocal dose for each feature and site
Classic: IsoFocal point is found when the 2nd derivative of the process window = 0
Bossung: IsoFocal deviant = the magnitude of the 3rd Bossung curve coefficient
Isofocal point is at the minimum for the curve
2) Lower curves: Level of aberrations for the dose plotted as magnitude of 2nd Bossung curve coefficient
Isofocal deviant curves
Aberration level at each dose
http://www.TEAsystems.com - 20Yield Enhancement thru ModelingTEA SystemsTEA Systems
Optimum Field Response thru Dose
BCD summarizes natural feature size response @ best Focus for each dose DoF computed when in control
Best Focus BCD4 (nm) DoF DoseMean: 0.0070 104.1780 18.0
Max: 0.0810 110.6640 18.0Min: -0.1570 100.6540 18.0IFD: 0.2380 10.0100 18.0
Mean: 0.0180 94.3450 0.0530 19.0Max: 0.0830 99.8950 0.0530 19.0Min: -0.1340 91.0560 0.0530 19.0IFD: 0.2170 8.8390 0.0000 19.0
Mean: 0.0330 84.4540 0.3560 20.0Max: 0.0940 88.9940 0.5970 20.0Min: -0.0740 81.4100 0.1710 20.0IFD: 0.1680 7.5840 0.4260 20.0
Mean: 0.1080 72.8100 0.6260 21.0Max: 0.9820 77.6260 0.6400 21.0Min: -0.1050 30.3330 0.5230 21.0IFD: 1.0870 47.2940 0.1170 21.0
Best Focus BCD4 (nm) DoF DoseMean: -0.0390 65.3970 0.0160 22.0
Max: 0.2880 70.2900 0.0210 22.0Min: -0.2800 61.7610 0.0110 22.0IFD: 0.5680 8.5290 0.0100 22.0
Mean: -0.0840 56.2490 23.0Max: -0.0320 59.1160 23.0Min: -0.1570 53.4410 23.0IFD: 0.1250 5.6740 23.0
Mean: -0.0570 46.2440 24.0Max: 0.0210 47.9520 24.0Min: -0.1340 43.7280 24.0IFD: 0.1550 4.2230 24.0
Best Focus BCD4 (nm) DoF DoseMean: -0.0390 65.3970 0.0160 22.0
Max: 0.2880 70.2900 0.0210 22.0Min: -0.2800 61.7610 0.0110 22.0IFD: 0.5680 8.5290 0.0100 22.0
Mean: -0.0840 56.2490 23.0Max: -0.0320 59.1160 23.0Min: -0.1570 53.4410 23.0IFD: 0.1250 5.6740 23.0
Mean: -0.0570 46.2440 24.0Max: 0.0210 47.9520 24.0Min: -0.1340 43.7280 24.0IFD: 0.1550 4.2230 24.0
http://www.TEAsystems.com
Weir DM Daily Monitor Interface
Macro-Encapsulation of Weir PW Analysis
One-Step data selection and analysis.
User customized:
Graphics
Statistics setup
Variable Trend Tracking
Variable ouput
http://www.TEAsystems.com - 22Yield Enhancement thru ModelingTEA SystemsTEA Systems
Weir DM Macro Types Weir PSFM focus reticle analyses
Focus/Expo Matrix Functionality
Best image analysis of lens aerial image Requirements
Benchmark PSFM reticle Initial dataset of a PSFM Focus matrix
Fixed-Focus Analysis Functionality
Analysis of wafer flatness, photoresist flatness, process focus and exposure tool autofocus/ auto-leveling stability.
Requirements Benchmark PSFM reticle Initial dataset of PSFM fixed-focus, full-wafer
Same layout and exposure as monitor wafers will be Same exposure as PSFM calibration tempalte
Weir PW analyses Raw Metrology Reticle Haze and Process Window Monitor
Raw metrology and tool Monitor are same Statistics and modeling on any metrology data set Requirements
Initial data set with same exposure and layout as future daily monitors
http://www.TEAsystems.com - 23Yield Enhancement thru ModelingTEA SystemsTEA Systems
Weir Macro setup for Process Window Analysis
Weir PW Example data – Forms basis for template
Template
http://www.TEAsystems.com - 24Yield Enhancement thru ModelingTEA SystemsTEA Systems
Selecting the Weir DM Analysis type
http://www.TEAsystems.com - 25Yield Enhancement thru ModelingTEA SystemsTEA Systems
Focus Dose PW Dose @ BF
Select from 4 types of analysis
Reticle Haze is best analyzed with the “Dose @ Best Focus” analysis
http://www.TEAsystems.com - 26Yield Enhancement thru ModelingTEA SystemsTEA Systems
Weir DM Target Values Setup
Variables are determined by user-data
Automated culling and modeling supported
http://www.TEAsystems.com - 27Yield Enhancement thru ModelingTEA SystemsTEA Systems
Selecting statistics for analysis & trend
http://www.TEAsystems.com - 28Yield Enhancement thru ModelingTEA SystemsTEA Systems
Optimum Dose Trend for mixed OPC - BCD
Dataset or date can be trended
on abscissa
http://www.TEAsystems.com - 29Yield Enhancement thru ModelingTEA SystemsTEA Systems
Reports that appear during the analysis of each data set. Upper chart summarizes the focus and dose for each site. Lower graph
displays the final dose-plot for all five sites of one data set.
Reports & Graphics for current dataset
http://www.TEAsystems.com - 30Yield Enhancement thru ModelingTEA SystemsTEA Systems
Call-Log for Weir DM
Can be used to track and perform analysis
diagnostics.
http://www.TEAsystems.com - 31Yield Enhancement thru ModelingTEA SystemsTEA Systems
Raw “Range” data for the 12 data sets analyzed. One interactive point, text is “yellow-note”, has been highlighted by the user’s mouse.
Raw as well as modeled data trends
http://www.TEAsystems.com - 32Yield Enhancement thru ModelingTEA SystemsTEA Systems
Reticle-Haze Sensitive Iso-Focal Dose
http://www.TEAsystems.com - 33Yield Enhancement thru ModelingTEA SystemsTEA Systems
Reticle-Haze IsoFocal Dose Range
http://www.TEAsystems.com - 34Yield Enhancement thru ModelingTEA SystemsTEA Systems
Feature-Size change with IsoFocal Dose
http://www.TEAsystems.com - 35Yield Enhancement thru ModelingTEA SystemsTEA Systems
Isofocal Dose with Message added by user.
http://www.TEAsystems.com - 36Yield Enhancement thru ModelingTEA SystemsTEA Systems
Summary Data Selection
For Full-Field for Process-Window detection of Reticle Haze
http://www.TEAsystems.com - 37Yield Enhancement thru ModelingTEA SystemsTEA Systems
User selections for monitoring
http://www.TEAsystems.com - 38Yield Enhancement thru ModelingTEA SystemsTEA Systems
Reticle Haze can also influence Best Focus Uniformity
Here Best Focus is calculated from the process-window Focus-Dose Matrix
http://www.TEAsystems.com - 39Yield Enhancement thru ModelingTEA SystemsTEA Systems
Dose %Latitude for five and one site studies
http://www.TEAsystems.com
Weir DMA - Daily Monitor Automation
Automation of Weir DM for calling by shop-flow and other control systems.
Includes input data specification, analysis logs, internal trends and data report outputs in text and html format.
http://www.TEAsystems.com - 41Yield Enhancement thru ModelingTEA SystemsTEA Systems
Run-log format Default folder = %Weir DM home%
Default = Weir DM home folder To change use “Tools/Options” menu and the DMA tab
File Name RemoteCall.Log Format = ASCII
Contents Contains analysis summary plus any errors Sample:
____ Weir DMA: ver: 3.8.55 ‘ start of new analysis System ID: 1C2CE5A7 Analysis Start: Wednesday, July 28, 2004 2:36:50 PM ‘ next line is the input command line Cmd: -t "C:\Program Files\Weir Wavefront Engineering\Templates\DS1_FF_DMtemplate.XLT" -d 040525153141.txt -o
D:\TEMP -x D:\TEMP runDM Start: 2:36:50 PM cmdLineParse Start: 2:36:50 PM ‘ command line interpreted correctly DM Start: 2:36:50 PM runDMoutput Start: 2:36:59 PM ‘ actual analysis start Output: D:\Temp\040525153141_WeirDMA.csv ‘ output to ASCII file Output 56 statistics. OutputXLS: D:\Temp\040525153141_WeirDMA.xls ‘ optional output to excel workbook Output 56 statistics. run DM successful ‘ signifies completion without errors Analysis End: Wednesday, July 28, 2004 2:37:00 PM …____
http://www.TEAsystems.com - 42Yield Enhancement thru ModelingTEA SystemsTEA Systems
Reticle Haze & Full-Field Process Window Monitor
Call DMA with Macro & Data
Import data &
save
Display current-
data graphic
Update Trend charts
Weir DMA output to ASCII (*.csv) and Excel
(*.xls) files
Weir DMA outputs status and any errors to RemoteCall.log
Optional: Model
wafer and field focus
http://www.TEAsystems.com - 43Yield Enhancement thru ModelingTEA SystemsTEA Systems
Moving a Weir DM macro
When moving a Weir DM macro to another computer: Copy the macro (*.XLT) into the new computer’s template directory Make sure the directories in the macro correspond to those in the new
computer: Data directory Macro storage directory Reticle storage directory
Insure the “Tools/Options” interface in the new computer specifies the proper data import filter. Import Filter can also be called by Weir DMA
http://www.TEAsystems.com
Weir DMA Example Analysis
http://www.TEAsystems.com - 45Yield Enhancement thru ModelingTEA SystemsTEA Systems
Check Weir DMA Options
Options interface is located on the Weir DM “Tools/Options” menu. Here we’ve changed the location of the DMA analysis log file “RemoteCall.log”
to the “D:\Temp” folder. The Max/Min options will be used to limit the size of this log file.
http://www.TEAsystems.com - 46Yield Enhancement thru ModelingTEA SystemsTEA Systems
Running Weir DMA – RemoteCall.log
This is the RemoteCall.log format
Switches used for the analysis are shown above-left
Screen shows the status output of two successful data runs
-t "C:\Program Files\Weir Wavefront Engineering\Templates\DS1_FF_DMtemplate.XLT"
-d 040615210805.txt -o D:\TEMP -x D:\TEMP
http://www.TEAsystems.com - 47Yield Enhancement thru ModelingTEA SystemsTEA Systems
RemoteCall.log This file will also show any
errors encountered and should be monitored regularly.
Weir DMA: ver: 3.8.56 System ID: 1C2CE5A7 Analysis Start: Friday, July 30, 2004 4:00:34 PM Cmd: -t "C:\Program Files\Weir Wavefront Engineering\Templates\DS1_FF_DMtemplate.XLT" -d 040615210805.txt -o D:\TEMP -x D:\TEMP runDM Start: 4:00:34 PM cmdLineParse Start: 4:00:34 PM DM Start: 4:00:34 PM runDMoutput Start: 4:00:43 PM Output: D:\Temp\040615210805_WeirDMA.csv Output 55 statistics. OutputXLS: D:\Temp\040615210805_WeirDMA.xls Output 55 statistics. run DM successfulAnalysis End: Friday, July 30, 2004 4:00:45 PM
http://www.TEAsystems.com - 48Yield Enhancement thru ModelingTEA SystemsTEA Systems
Files in output directory
• Consist of two sets of ASCII and XLS output data files along with the call log.
http://www.TEAsystems.com - 49Yield Enhancement thru ModelingTEA SystemsTEA Systems
,FocusMin::,0,,[EndHeader],,,,,,[Results],,,,,,[Z (Mean)],,,Wafers:,1,,Sites/Die:,2,,#Dice:,5,,IFD:,0.199,,BF(Fitted):,0.000,,X Tilt(urad):,0.000,,Y Tilt(urad):,0.000,,Astigmatism:,0.135,,Curv(nm/cm2):,0.000,,IFDresid(um):,0.000,,StDEVresid(um):,0.000,,Count:,10,,Mean:,0.017,,Median:,0.036,,SEM:,0.018,,Maximum:,0.136,,Minimum:,-0.063,,Range:,0.199,,MinMax:,0.136,,StDev:,0.058,,Mean+3Sigma:,0.190,,[EndResults],,,[END],,
,FocusMin::,0,,[EndHeader],,,,,,[Results],,,,,,[Z (Mean)],,,Wafers:,1,,Sites/Die:,2,,#Dice:,5,,IFD:,0.199,,BF(Fitted):,0.000,,X Tilt(urad):,0.000,,Y Tilt(urad):,0.000,,Astigmatism:,0.135,,Curv(nm/cm2):,0.000,,IFDresid(um):,0.000,,StDEVresid(um):,0.000,,Count:,10,,Mean:,0.017,,Median:,0.036,,SEM:,0.018,,Maximum:,0.136,,Minimum:,-0.063,,Range:,0.199,,MinMax:,0.136,,StDev:,0.058,,Mean+3Sigma:,0.190,,[EndResults],,,[END],,
Output Data File Partial display of
output file Specifications
are in the manual.
Each section of the data is summarized by a header line in “[]” brackets
,[Data],,,Program:,Weir DMA,,,,,DataFile:,040525153141.txt,,DataFolder:,D:\Data\UMC\WeirDM Testing,,Template:,DS1_FF_DMtemplate.XLT,,TemplateFolder:,C:\Program Files\Weir Wavefront Engineering\Templates,,AnalysisDate:,7/28/2004,,AnalysisTime:,12:00:00 AM,,Tool:,,,Wafers:,1,,,,,[Header],,,DateTemplateSaved:,7/27/2004,,Analysis:,Fixed Focus,,FocusTemplate:,UMC DS5-Step2,,ConversionMethod:,All Sites,,ModelData:,True,,Statistics:,1,,Graphic:,1,,GraphicData:,0,,WaferFieldGraphic:,Wafer,,GraphicPlot:,Vector,,GraphicDataFormat:,All Points,,Comments:,,,Summary:,Analysis:Fixed Focus:All Sites (UMC DS5-Step2)
,[Data],,,Program:,Weir DMA,,,,,DataFile:,040525153141.txt,,DataFolder:,D:\Data\UMC\WeirDM Testing,,Template:,DS1_FF_DMtemplate.XLT,,TemplateFolder:,C:\Program Files\Weir Wavefront Engineering\Templates,,AnalysisDate:,7/28/2004,,AnalysisTime:,12:00:00 AM,,Tool:,,,Wafers:,1,,,,,[Header],,,DateTemplateSaved:,7/27/2004,,Analysis:,Fixed Focus,,FocusTemplate:,UMC DS5-Step2,,ConversionMethod:,All Sites,,ModelData:,True,,Statistics:,1,,Graphic:,1,,GraphicData:,0,,WaferFieldGraphic:,Wafer,,GraphicPlot:,Vector,,GraphicDataFormat:,All Points,,Comments:,,,Summary:,Analysis:Fixed Focus:All Sites (UMC DS5-Step2)
http://www.TEAsystems.com - 50Yield Enhancement thru ModelingTEA SystemsTEA Systems
Trend summary• The modeled summary of the
8 data files can be found if we go back into Weir DM
http://www.TEAsystems.com - 51Yield Enhancement thru ModelingTEA SystemsTEA Systems
Data contents
• Plots the # of sites per field.
• Only last two data sets correspond to the 63 sites per field of the calibration template
http://www.TEAsystems.com - 52Yield Enhancement thru ModelingTEA SystemsTEA Systems
Weir DMA features
Features Ability to limit the size of the RemoteCall.log file Ability to select a window size and location in the trend plot for plots with
many data entries. DMA screen for status reporting of DMA calls
Interactive beyond RemoteCall.log file. Done Aug. 2004 along with ability to control the length of display time for
this screen. Data Import Format included in Weir DM Template Ability to select focus models Ability to select full-field, full wafer and slit/scan models for focus or any