r
Version Upgrade Instructions
HUAWEI BSC6000 V900R003Upgrade Guide
Issue 1.00
Date 2007-12-29
内部使用
HUAWEI TECHNOLOGIES CO., LTD.
INTERNALUSE
HUAWEI BSC6000 V900R003
Upgrade Guide
Huawei Technologies Co., Ltd. provides customers with comprehensive technical support and service. Please feel free to contact our local office or company headquarters.
Huawei Technologies Co., Ltd.
Address: Huawei Industrial Base
Bantian, Longgang
Shenzhen 518129
People's Republic of China
Website: http://www.huawei.com
Email: [email protected]
Copyright © Huawei Technologies Co., Ltd. 2007. All rights reserved.
No part of this document may be reproduced or transmitted in any form or by any means without prior written consent of Huawei Technologies Co., Ltd.
Trademarks and Permissions
and other Huawei trademarks are trademarks of Huawei Technologies Co., Ltd.
All other trademarks and trade names mentioned in this document are the property of their respective holders.
Notice
The information in this document is subject to change without notice. Every effort has been made in the
preparation of this document to ensure accuracy of the contents, but all statements, information, and
recommendations in this document do not constitute the warranty of any kind, express or implied.
Issue 1.00 (2007-12-29)Huawei Proprietary and Confidential
Page 2 of 84
INTERNALUSE
HUAWEI BSC6000 V900R003
Upgrade Guide
About This Document
Authors
Prepared by Yu Zhiguo、Wang Guanghui Date: 2007-12-29
Reviewed by Zhou Liang, Liu Ying, Yangjian,
Wang Dong, Guo Gaorong
Date: 2007-12-29
Approved by Fang Wei Date: 2007-12-29
Summary
You are advised to read the entire document prior to using HUAWEI
BSC6000V900R003C01. This document contains the following contents:
Section Details
Error: Reference source not found
Version Requirements for Upgrade
Describes the requirements for the confirmation of
the source version required to be upgraded and the
target version before the upgrade
Error: Reference source not found
Upgrade Flow Chart
Describes the whole procedures for upgrading the
version.
3 Error: Reference source not
found
Describes the preparations before the upgrade and
the health check.
Issue 1.00 (2007-12-29)Huawei Proprietary and Confidential
Page 3 of 84
INTERNALUSE
HUAWEI BSC6000 V900R003
Upgrade Guide
Error: Reference source not foundL
ocal Upgrade Operations
Error: Reference source not foundR
emote Upgrade Operations
Describes the actual procedures for the upgrade. The
upgrade must conform to the procedures strictly.
7 Upgrade Verification Describes the verification of the upgraded version
and equipment. The normal running of the upgraded
system can be ensured.
Error: Reference source not found
Version Rollback
Describes the processing procedures for failed
upgrade or other reasons.
9 FAQ Describes the records of collected important
problems related to the version upgrade.
History
版本 描述 发布日期 作者 签发人
1.00 the first release 2007-12-29 YuZhiguo,WangGuanghui Fangwei
Issue 1.00 (2007-12-29)Huawei Proprietary and Confidential
Page 4 of 84
INTERNALUSE
HUAWEI BSC6000 V900R003
Upgrade Guide
Contents
1 Version Requirements for Upgrade...............................................10
2 Upgrade Flow Chart.....................................................................11
3 Preparations for Upgrade.............................................................13
3.1 Checklist Before Upgrade................................................................................................................................13
3.2 Preparations for Upgrade.................................................................................................................................13
3.3 Checking the Versions Before the Upgrade.....................................................................................................14
3.3.1 Host Version...........................................................................................................................................14
3.3.2 Version Mapping of the M2000..............................................................................................................14
3.3.3 Version Mapping of Level 2 BIOS.........................................................................................................15
3.4 Required Software in the Preparations for upgrade.........................................................................................15
3.5 Preparing the License.......................................................................................................................................17
3.5.1 Change in Control of the License...........................................................................................................17
3.5.2 Applying for the License........................................................................................................................18
3.5.3 Checking the License..............................................................................................................................18
3.6 Checking the Correctness of the DIP Switches for Subracks..........................................................................19
3.7 Matters to Note in Upgrade.............................................................................................................................19
4 Local Upgrade Operations............................................................21
4.1 Backing Up Data and Board Software.............................................................................................................21
4.1.1 Backing Up Data....................................................................................................................................21
4.1.2 Backing Up Software..............................................................................................................................22
4.1.3 Backing Up the License..........................................................................................................................23
4.2 Backing Up Data Configuration Files.............................................................................................................23
Issue 1.00 (2007-12-29)Huawei Proprietary and Confidential
Page 5 of 84
INTERNALUSE
HUAWEI BSC6000 V900R003
Upgrade Guide
4.2.1 Checking the Current System.................................................................................................................23
4.2.2 Backing Up Data Configuration Files....................................................................................................24
4.3 Loading the Host Software Online..................................................................................................................24
4.3.1 Downloading Upgrade Package.............................................................................................................25
4.3.2 Loading the Host Software to a Board Online.......................................................................................26
4.4 Loading the Level 2 BIOS to a Board Online..................................................................................................26
4.4.1 Loading Level 2 BIOS File Online.........................................................................................................27
4.5 Upgrading the LMT.........................................................................................................................................28
4.6 Upgrading the Configuration Data File...........................................................................................................29
4.6.1 Upgrading the Configuration Data File..................................................................................................29
4.6.2 Prepraring the Configuration Data File..................................................................................................31
4.7 Upgrading GBAM and Single GOMU............................................................................................................31
4.7.1 Operation Preparations...........................................................................................................................32
4.7.2 Upgrading the GBAM............................................................................................................................34
4.7.3 Upgrading the GOMU............................................................................................................................34
4.7.4 Verify OMU version...............................................................................................................................34
4.8 Upgrading Active/Standby GOMU.................................................................................................................34
4.9 Data Restoration..............................................................................................................................................40
4.10 Upgrading Board Software............................................................................................................................44
4.10.1 Preparations..........................................................................................................................................44
4.10.2 Procedures for the Upgrade..................................................................................................................44
4.10.3 Confirming the Board State..................................................................................................................45
4.10.4 Exception Handling..............................................................................................................................45
4.11 Activating the Software License....................................................................................................................46
5 Installing the M2000 Adaptation Layer..........................................47
6 Remote Upgrade Operations.........................................................48
6.1 Preparations.....................................................................................................................................................48
6.2 Procedures for the Upgrade.............................................................................................................................49
6.2.1 Creating the NE Objects.........................................................................................................................49
6.2.2 Uploading Software and Data.................................................................................................................49
Issue 1.00 (2007-12-29)Huawei Proprietary and Confidential
Page 6 of 84
INTERNALUSE
HUAWEI BSC6000 V900R003
Upgrade Guide
6.2.3 Performing the Upgrade.........................................................................................................................50
6.2.4 Download and Activate License.............................................................................................................52
7 Upgrade Verification....................................................................53
7.1 Verification Checklist.......................................................................................................................................53
7.2 Verification After the Upgrade.........................................................................................................................53
7.3 Completing the Upgrade..................................................................................................................................55
7.3.1 Sanitation in the Environment After the Upgrade Succeeds..................................................................55
8 Version Rollback..........................................................................56
8.1 Precautions.......................................................................................................................................................56
8.2 Rollbacking OMU Software............................................................................................................................56
8.3 Restore old data and old board software..........................................................................................................58
8.4 Starting the OMU Software.............................................................................................................................59
8.5 Rolling Back Board Software..........................................................................................................................59
8.6 Rolling back LMT...........................................................................................................................................60
8.7 Verification.......................................................................................................................................................60
9 FAQ.............................................................................................61
9.1 FAQ Index........................................................................................................................................................61
9.2 FAQ1................................................................................................................................................................61
A Upgrade Preparations..................................................................62
B Upgrade Record...........................................................................64
C Checklist for Dialing Test..............................................................65
D Checklist for System Health Before the Upgrade...........................68
E Checklist for System Health After the Upgrade..............................71
F Checklist for the Configuration Information on License Files..........76
G Acronyms and Abbreviations.........................................................................77
Issue 1.00 (2007-12-29)Huawei Proprietary and Confidential
Page 7 of 84
INTERNALUSE
HUAWEI BSC6000 V900R003
Upgrade Guide
Figures
Figure 3-1 Operating status of equipment.............................................................................................................19
Issue 1.00 (2007-12-29)Huawei Proprietary and Confidential
Page 8 of 84
INTERNALUSE
HUAWEI BSC6000 V900R003
Upgrade Guide
Tables
Table 2-1 Procedures for upgrading a version.......................................................................................................11
Table 3-1 Table 3-1 lists the mapping between the latest versions:...................................................................15
Table 3-2 Version mapping of BSC6000 level 2 BIOS.........................................................................................15
Table 3-3 lists the BSC6000 software directory structure...................................................................................16
Table 3-4 Change in control of the License in BSC6000V900R003C01..............................................................17
Table 6-1 Checklist for the verification items.......................................................................................................54
Table 8-1 FAQ list.................................................................................................................................................62
Issue 1.00 (2007-12-29)Huawei Proprietary and Confidential
Page 9 of 84
INTERNALUSE
HUAWEI BSC6000 V900R003
Upgrade Guide
1 Version Requirements for Upgrade
This upgrade guide applies to the upgrade from an earlier release to a later release of BSC6000V900R003. In
addition, it applies to the upgrade from an earlier release to a later release of GBAM or GOMU. For the upgrade
from the GBAM to the GOMU, refer to the Guide to the Upgrade from the GBAM to the GOMU in
BSC6000V900R003.
Issue 1.00 (2007-12-29)Huawei Proprietary and Confidential
Page 10 of 84
INTERNALUSE
HUAWEI BSC6000 V900R003
Upgrade Guide
2 Upgrade Flow Chart
lists the procedures for upgrading a version.:
Table 2-1 Procedures for upgrading a version
Step Operation ReferenceDuration (For
Reference Only)
1Preparation
Section 3 Depend on your actual
requirements
2Back up data and
software
Section Error:
Reference source not
found
Depend on the actual
data volume
3Back up data
configuration files
Section Error:
Reference source not
found
5 minutes
4Load the host software
online
Section Error:
Reference source not
found
15 minutes
5Load the Level 2 BIOS
online
Section Error:
Reference source not
found
10 minutes
Issue 1.00 (2007-12-29)Huawei Proprietary and Confidential
Page 11 of 84
INTERNALUSE
HUAWEI BSC6000 V900R003
Upgrade Guide
Step Operation ReferenceDuration (For
Reference Only)
6
Upgrade the LMT
Section Error:
Reference source not
found
15 minutes
7Upgrade data
configuration files
Section Error:
Reference source not
found
10 minutes
8
Upgrade OMU software
Section Error:
Reference source not
found
15 minutes
9 Restore data Section 15 3 minutes
10
Upgrade board software
Section 4.10 If step 5 is skipped,
duration of the step is 25
minutes. Otherwise, the
duration of the step is 15
minutes.
11 Download and activate
the software license
Section 4.11 5 minutes
12 Install the software that
is in M2000 adaptation
layer
Section 5 40 minutes
13 Remote Upgrate
Operation
Section 6 30 minutes
14 Check the running status
after the upgrade
Section 7.2 2 minutes
15Clean up the site after the
upgrade
Section Error:
Reference source not
found
2 minutes
Issue 1.00 (2007-12-29)Huawei Proprietary and Confidential
Page 12 of 84
INTERNALUSE
HUAWEI BSC6000 V900R003
Upgrade Guide
3 Preparations for Upgrade
3.1 Checklist Before Upgrade
No. Item Check Points Result
1 Preparations Complete the health
check before the upgrade
and prepare the records of
upgrade preparation
2 Version check before upgrade Confirm the correctness
of the upgraded version
and the consistency
3 Preparations for the software
required for the upgrade
Prepare the software
required for the upgrade
4 Preparation for the license Prepare the license and
complete the verification
5 Check of DIP switches on subracks Ensure that subracks are in non-auto start mode.
Issue 1.00 (2007-12-29)Huawei Proprietary and Confidential
Page 13 of 84
INTERNALUSE
HUAWEI BSC6000 V900R003
Upgrade Guide
3.2 Preparations for Upgrade
Before the upgrade, the related owner needs to perform system check based on Appendix D
"."
In preparation stage, the related owner needs to prepare the upgrade based on Appendix A
"Upgrade Preparations." and records the upgrade preparations.
3.3 Checking the Versions Before the Upgrade
3.3.1 Host Version
CAUTION
For batch delivery, the initial version is specified as required in delivery. For the initial
installation, related check and configuration are necessary. For details, refer to the BSC6000
V900R003 GOMU Administration Guide. This document is used only to introduce the version
upgrade.
The host version is checked as follows:
Step 1 Log in to the LMT, and then connect the LMT to the GBAM
Step 2 Log in to the LMT, and then choose Help > About to view the information on versions. For
detailed information on version B, press Ctrl+Shift+F12.
----End
3.3.2 Version Mapping of the M2000
To ensure that NEs are maintained normally and the BSC6000 versions are upgraded
normally, the personnel in charge of the upgrade must ensure the mapping between the
BSC6000 versions and M2000 adaptation layer and also the mapping between the server and
the versions on the client.
Issue 1.00 (2007-12-29)Huawei Proprietary and Confidential
Page 14 of 84
INTERNALUSE
HUAWEI BSC6000 V900R003
Upgrade Guide
Table 3-1 Error: Reference source not found lists the mapping between the latest versions:
BSC6000
Version
Version in M2000 Adaptation Layer M2000
Server/Client
Version
BSC6000V900R003
C01B032
iManagerM2000_BSC6000_MATCH_ENG_V
200R005C01B032
iManagerM2000_BSC6000_MATCH_CHS_V
200R005C01B032
iManagerM2000
V200R005C01B7
60
BSC6000V900R003
C01B061
iManagerM2000_BSC6000_MATCH_ENG_V
200R005C01B039
iManagerM2000_BSC6000_MATCH_CHS_V
200R005C01B039
iManagerM2000
V200R006C01B7
60SP01
BSC6000V900R003
C01B061SP01
iManagerM2000_BSC6000_MATCH_ENG_V
200R005C01B039SP02
iManagerM2000_BSC6000_MATCH_CHS_V
200R005C01B039SP02
iManagerM2000
V200R006C01B7
60SP01
BSC6000V900R003
C01B062
iManagerM2000_BSC6000_MATCH_CHS_V
200R005C01B041.tar
iManagerM2000_BSC6000_MATCH_ENG_V
200R005C01B041.tar
iManagerM2000
V200R005C01B7
60SP01
BSC6000V900R003
C01B070
iManagerM2000_BSC6000_MATCH_CHS_V
200R006C01B370.tar
iManagerM2000_BSC6000_MATCH_ENG_V
200R006C01B370.tar
iManagerM2000
V200R005C01B7
60SP01
Issue 1.00 (2007-12-29)Huawei Proprietary and Confidential
Page 15 of 84
INTERNALUSE
HUAWEI BSC6000 V900R003
Upgrade Guide
3.3.3 Version Mapping of Level 2 BIOS
Table 3-1 Version mapping of BSC6000 level 2 BIOS
BSC6000 Active Version Level 2 BIOS Version
BSC6000V900R003C01B032 GXPUT/GXPUM:207
Others:206
BSC6000V900R003C01B061 GXPUT/GXPUM、GEIU/GOIU、GDPUC:208
GTNU:207
Others:206
BSC6000V900R003C01B070 GXPUT/GXPUM、GEIU/GOIU、GDPUC:208
GTNU:207
Others: 206
3.4 Required Software in the Preparations for
upgrade
The BSC6000 software consists of the LMT installation disk, OMU installation package,
compressed host software package, and scripts used in the upgrade.
Table 3-1 Error: Reference source not found lists the BSC6000 software directory structure.
catalog comment
version x—C version number
yy—B version number
HOST Host software directory
GBAM Host software document directory
Issue 1.00 (2007-12-29)Huawei Proprietary and Confidential
Page 16 of 84
INTERNALUSE
HUAWEI BSC6000 V900R003
Upgrade Guide
released commercially
boardfile.9.3.x.yy.zip
Compressed board software
package is used to upgrade
software on boards.
omu-9.3.x-yy.i586.rpmOMU software package is used to
upgrade the OMU software.
verpkg.xml
Upgrade package version mapping
file is used to check the correctness
of board software and OMU
software during the upgrade.
upgradecfg.xml
Remote upgrade configuration file
is used only in remote upgrade.
The file is unnecessary in local
upgrade.
vercfg.xml
Remote upgrade version mapping
file is used only in remote upgrade.
The file is unnecessary in local
upgrade.
LMT LMT software directory
BSC6000V900R003C0xB0yyLMT installation disk is used to
upgrade the LMT software.
To obtain the required software packages and documents during the deployment, do as follows:
Open the web page http://support.huawei.com.
Step 2 Choose Technical Support > Software > Version Software > Wireless Product Line > GSM-BSS > GSM-BSC6000 > HUAWEI BSC6000 V900R003 > HUAWEI BSC6000 V900R003C01B0yy
Step 3 Download the required software by clicking Software, and download the required documents by clicking Documentation.
Step 4 After the software is downloaded, decompress the software package to obtain the required files for the installation described in Error: Reference source not found.
--End
Issue 1.00 (2007-12-29)Huawei Proprietary and Confidential
Page 17 of 84
INTERNALUSE
HUAWEI BSC6000 V900R003
Upgrade Guide
NOTE
1、 To download the putty tool, choose Technical Support > Software > Mini-tool
software > Wireless > GBSS Product Maintenance Tools > MDN-Putty.
2、 The network management software, which consists of the installation package of the
M2000 server, installation package at M2000 adaptation layer, and report template,
should be downloaded independently. You can choose Technical Support >
Software > Version Software > Core Network > Wireless-OSS to download the
software.
3.5 Preparing the License
3.5.1 Change in Control of the License
Table 3-1 Change in control of the License in BSC6000V900R003C01
New Control Item in
BSC6000V900R003C01
Deleted Control Item in
BSC6000V900R003C01
Number of TRXs supporting BTS local
switching
Number of TRXs supporting BSC local
switching
Number of TRXs supporting FLEX ABIS
Supporting the MSC POOL function
Issue 1.00 (2007-12-29)Huawei Proprietary and Confidential
Page 18 of 84
INTERNALUSE
HUAWEI BSC6000 V900R003
Upgrade Guide
3.5.2 Applying for the License
NOTE
1. The license file must be applied for at least three workdays in
advance.
2. Pay attention to the values of the license control items when applying
for a license. The applied values must be within the value range. For
the valid value of each license control item, refer to the License
Template in the License Workflow in notes.
You need to apply for a new license in the following situations::
On a new deployment site
New license control items are added to the version to be upgraded. These license control items are not contained in the license files in earlier version.
New license control items are added to the version to be upgraded. These license control items are contained in the license files in earlier version, however, their values are incorrect.
ESN is changed. For the method of checking the ESN, refer to section 3.5.3 "Checking the License."
Onsite capacity expansion
V9R1 is upgraded to V9R3.
For the procedures for applying for the license file, refer to the GSM BSS LICENSE Application Procedure at http://support.huawei.com.
For the procedures for applying for the license file, refer to the GSM BSS LICENSE
Application Procedure at http://support.huawei.com.
3.5.3 Checking the License
CAUTION
1. The fixed length of the BSC6000 ESN is 40 bytes.
To check the ESN of the license offline, do as follows:
Issue 1.00 (2007-12-29)Huawei Proprietary and Confidential
Page 19 of 84
INTERNALUSE
HUAWEI BSC6000 V900R003
Upgrade Guide
Step 1 Log in to the LMT that is newly installed offline and check the ESN of the system. Choose BSC Maintenance > Maintain License > Query ESN. In the displayed dialog box, enter the OSP (BSC signaling point in the GMPS) and the DSP (MSC signaling point). Click Generate. Record the ESN in Appendix F "Checklist for the Configuration Information on License Files."
Step 2 Check the license file offline. Obtain the ESN information in the license file and record it in Appendix F "Checklist for the Configuration Information on License Files." Compare it with the ESN recorded in step 1.If they are inconsistent, apply for a new license file and end this upgrade.
----End
3.6 Checking the Correctness of the DIP Switches for
Subracks
Check bit 8 of DIP switches on each subrack. You need to perform the following operation
based on the result:
Set bit 8 of the DIP switches on the subracks where the DIP switches are in OFF
state to ON (in non-auto start mode). At the same time, inverse bit 6 (parity check
bit) to the opposite side.
If bit 8 is ON, the states of bit 8 and bit 6 are unnecessary to be changed.
3.7 Matters to Note in Upgrade
1. Before the upgrade, you must be familiar with the upgrade procedures and strictly follow
the procedures described in this document step by step.。
2. During the upgrade, wait until receiving a response after running a command, and then
you can perform the next step
3. Before the upgrade, check the operating status of boards. On the BSC Device Panel tab
page of the LMT, you can view the operating status of a board. The active board in
normal state is green and the standby board in normal state is light blue, as shown in the
following figure.
Issue 1.00 (2007-12-29)Huawei Proprietary and Confidential
Page 20 of 84
INTERNALUSE
HUAWEI BSC6000 V900R003
Upgrade Guide
Figure 3-1 Operating status of equipment
4. During the upgrade, the following operations on the GBAM are forbidden:
− Power off the GBAM
− Manually reset the GBAM
− Manually disconnect the GBAM from the network
5. During the upgrade, before the board initialization is complete, do not configure any
data. Otherwise, the board data and the data on the GBAM/GOMU may be inconsistent
and the following operations are affected.
NOTE
To determine whether the board initialization is complete, do as follows:
a) The GXPUM/GXPUT has four CPUs, therefore, the initialization of the GXPUM/GXPUT cannot be
complete until all the CPUs are initialized. You can right-click the GXPUM/GXPUT and choose Query
CPU/DSP State on the shortcut menu, and then click Query to check whether the initialization is complete.
Ensure that the Operation State of the four CPUs is Enabled, and the Available State of the four CPUs is
Normal. Otherwise, one CPU is abnormal.
b) For other boards, check their states on the BSC Device Panel tab page of the LMT. Ensure
that these boards are normal.
6. If the upgrade fails, or that the network performance deteriorates seriously after the
upgrade, you need to decide whether to roll back the version based on the actual situation
and customer requirements. For details about the rollback, refer to chapter 8 "Version
Rollback."
7. During the upgrade, ensure that all load control parameters are Automatic Loading.
Issue 1.00 (2007-12-29)Huawei Proprietary and Confidential
Page 21 of 84
INTERNALUSE
HUAWEI BSC6000 V900R003
Upgrade Guide
4 Local Upgrade Operations
CAUTION
The personnel in charge of the upgrade need to record related activities by referring to
Appendix B "Upgrade Record." and to provide the upgrade report.
4.1 Backing Up Data and Board Software
4.1.1 Backing Up Data
The BSC6000 data is stored under /bsc6000/data of the GBAM/GOMU. Some files contained
in this directory are listed as follows:
Data configuration files
Alarm files
Performance files
Log files
Tracing files stored on the GBAM/GOMU
Issue 1.00 (2007-12-29)Huawei Proprietary and Confidential
Page 22 of 84
INTERNALUSE
HUAWEI BSC6000 V900R003
Upgrade Guide
To back up the required files through samba, do as follows:
Step 1 On the Windows operating system, choose Start > Run.
Step 2 Connect to the GBAM/GOMU (assume that the IP address of the GBAM/GOMU is 10.161.72.254) by running \\10.161.72.254.
Step 3 Click OK.
NOTE
If a prompt that "Cannot find the \\GBAM IP address" is displayed on the Windows operating
system, you can infer that the samba service on the GBAM is not enabled. To enable the
samba service, you can use the putty tool to log in to the GBAM as user root, and then run the
rcsmb start command. Finally, log in to the GBAM through the Windows operating system.
Step 4 Double-click the bsc6000 folder. Enter the user name and password in the displayed dialog box correctly. By default, the user name is BSC6000 and the password is 11111111.
Step 5 Modify the attributes of the folders and files in the /BSC6000 directory.
You need to use the putty tool to log in to the GBAM/GOMU as user root, and then run the
chmod 777 /BSC6000 –R command on the putty tool to modify the attributes of all the
folders and that of all the files in the /BSC6000 directory.
Step 6 Enable the samba service to log in to the GBAM/GOMU, and then copy the files in the data directory to the local hard disk.
----End
4.1.2 Backing Up Software
To back up the BSC6000 software stored in the /bsc6000/bscswm directory on the
GBAM/GOMU, do as follows:
Step 1 On the Windows operating system, choose Start > Run.
Step 2 Enter the IP address of the GBAM/GOMU. For example, enter \\10.161.72.254, and then click OK.
Step 3 Double-click the bsc6000 folder. Enter the user name and password in the displayed dialog box correctly. The user name is BSC6000 and the password is 11111111 by default.
Step 4 Modify the attributes of all the folders and that of all the files in the /BSC6000 directory. Then, back up the bscswm directory on the GBAM/GOMU.
Use the putty tool to log in to the GBAM as user root.
Modify the attributes of all the folders and that of all the files in the /BSC6000
directory.
Issue 1.00 (2007-12-29)Huawei Proprietary and Confidential
Page 23 of 84
INTERNALUSE
HUAWEI BSC6000 V900R003
Upgrade Guide
# chmod 777 /BSC6000 -R
Back up the bscswm directory on the GBAM/GOMU:
# cp /BSC6000/bscswm /BSC6000/bscswmb0xx -R
In "bscswmb0xx", "xx" represents the current version number. You need to enter it
based on the actual situation.
Step 5 Copy the bscswmb0xx directory to the local hard disk, and then delete it on the GBAM/GOMU.
---End
4.1.3 Backing Up the License
This task applies to only sites where licenses are applied for and activated. To back up the
license, do as follows:
Step 1 Check and save the configuration information of the license file. Choose BSC Maintenance > Maintain License > Query License. Click Query. Fill the viewed configuration information into Appendix F "Checklist for the Configuration Information on License Files." If the license is newly applied, enter None in the Before Upgrade column.
Step 2 Check whether the license file is saved in the local hard disk. By default, the license file is saved in the \Common\SWM\license directory in earlier version. If the license file is saved in the local hard disk, backup is unnecessary. Otherwise, go to step 3.
Step 3 Enable the samba service to log in to the GBAM/GOMU, and then copy the folder in the \bsc6000\bscswm\area1\license directory to the local hard disk.
----End
4.2 Backing Up Data Configuration Files
4.2.1 Checking the Current System
Check all load control parameters of boards, except that of the GBAM/GOMU, and then ensure that
they are Auto. The method is as follows:
Step 1 On the LMT, choose BSC Maintenance > Query Software > Query Board Version Information.
Step 2 In the displayed Query Board Version Information dialog box, click the Load Option tab. On the Load Option tab page, choose each subrack (except subrack 12) in the Subrack drop-down list box in turn.
Step 3 Click Query to check the Load Option of all the boards in subracks.
Issue 1.00 (2007-12-29)Huawei Proprietary and Confidential
Page 24 of 84
INTERNALUSE
HUAWEI BSC6000 V900R003
Upgrade Guide
Step 4 If there are boards that are not loaded in Auto mode, find the corresponding board on the BSC Device Panel tab page, and then right-click it to choose Configure Board Attributes on the shortcut menu.
Step 5 On the BSC Device Panel dialog box, set the load control parameters to Automatic Loading. Then, wait for a prompt about the information on valid setting.
---End
4.2.2 Backing Up Data Configuration Files
1. Application Scenario
The configuration data before the upgrade can be used.
2. Software and Hardware Preparations:
One PC that is installed with the Windows2000 or WindowsXP operating system
and can log in to the GBAM/GOMU through the network;
LMT in earlier version
3. Operating mode:
4.3 Loading the Host Software Online
NOTE
1. This task can be performed to accelerate the board loading and shortens the service
interruption.
2. In this task, the host software does not include the upgrade of the core process or that of
the local process of the GBAM/GOMU.
3. Normally, V9R3C01B054 and later releases only support the upgrade from an earlier C
version to a later C version. To perform upgrade from an earlier B version to a later B
version, you should enable the B version upgrade function before the upgrade. In other
words, you should run the SET SWMDBG:DS=ON command on the MML client. The
version number entered during the upgrade should include the B version number.
Issue 1.00 (2007-12-29)Huawei Proprietary and Confidential
Page 25 of 84
INTERNALUSE
HUAWEI BSC6000 V900R003
Upgrade Guide
Loading host software online refers to loading the host software in later version by using the
MML client and the GBAM/GOMU to the Flash of each board. The following sections
describe how to load host software online.
4.3.1 Downloading Upgrade Package
The upgrade package to the GBAM can be downloaded through the MML client:
Step 1 Copy the upgrade package (omu-9.3.x-yy.i586.rpm and boardfile.9.3.x.yy.zip) and the version configuration table (verpkg.xml) of the upgrade package to the common\SWM directory, which is the relative directory for the LMT installation path, and start the FTP Server in Common\FtpServer directory installed with LMT.
Step 2 On the MML client, run a command to download the upgrade package and then observe the download progress and download result on the MML client.Choose MML Commands > System Management > Software Management > Version Management > Download and Unzip the Installation Package.
DLD VERPKG: IP="local IP address", DIR="Common\SWM\software",
SV="BSC6000V900R003C01";
IP indicates the IP address of the FTP server. USR indicates the user name (swmtest)
that is used for logging in to the FTP server. PWD indicates the password (swmtest) that
is used for logging in to the FTP server. DIR indicates the directory (for example,
common\SWM\b099) for storing and loading versions on the FTP server. (You can click
or press F9.)
Step 3 On the MML client, query the version of the host software. Then confirm that the host software in later version is contained in the version area of the GBAM. Choose MML Commands > System Management > Software Management > Version Management > List Software Version. (You can click or press F9.)
LST SOFTWARE:;
----End
Issue 1.00 (2007-12-29)Huawei Proprietary and Confidential
Page 26 of 84
INTERNALUSE
HUAWEI BSC6000 V900R003
Upgrade Guide
4.3.2 Loading the Host Software to a Board Online
The host software file can be loaded from the GBAM/GOMU to a board through the MML
client.,do as follows:
1. On the MML client, choose MML Commands > System Management > Software
Management > Version Management > Load Software Online. Then, run a command
to load the host software. Set Software type to BIN (software), and then set Software
version. You can click or press F9.
LOD SOFTWARE: SV="BSC6000V900R003C01";
2. On the MML client, observe the load progress. After the load is complete, the load result
is displayed on the MML client.
3. If the returned message indicates that the software fails to be loaded on some certain
boards, repeat step 1 through step 3. Because incremental load is achieved, the system
reloads software to only the boards where software fails to be loaded. If several attempts
for loading the software to some boards are made but all the attempts fail, check the
reason why the loading fails and perform the corresponding processing.
NOTE
If the OMLs on the Ater interface are in satellite transmission mode, the transmission of the
OMLs on the Ater interface is slow due to time delay. Therefore, the host software may not be
successfully loaded on the boards configured on the MSC side online at a time. In this case,
you can perform the load operation several times until all the boards are successfully loaded
with the host software.
4.4 Loading the Level 2 BIOS to a Board Online
NOTE
1、Before loading the level 2 BIOS, check the LMT device panel to ensure that all the boards
are operational.
2、When loading the level 2 BIOS online, select the corresponding level 2 BIOS version. The
version may be the same as the previous version.
Issue 1.00 (2007-12-29)Huawei Proprietary and Confidential
Page 27 of 84
INTERNALUSE
HUAWEI BSC6000 V900R003
Upgrade Guide
3、The BIOS upgrade consists of the upgrade of BIOS0 and BIOS1. The BIOS upgrade on the
M2000 or MML client refers to the upgrade of BIOS1, which is level 2 BIOS. Level 2 BIOS
is upgraded on the M2000 or MML client unless otherwise specified. The rollback of the
BIOS indicates the following: If the board was not powered off and the number of startup
failures reaches 200 after level 2 BIOS is upgraded, the original BIOS (BIOS0) is used to
perform startup. If the board was once powered off and the number of startup failures reaches
10 after level 2 BIOS is upgraded, the original BIOS (BIOS0) is used to perform startup.
The online loading of the level 2 BIOS indicates that the level 2 BIOS file in later version is
loaded on boards through the MML client and the GBAM/GOMU.
4.4.1 Loading Level 2 BIOS File Online
The level 2 BIOS file is loaded from the GBAM to boards through the M2000 or the MML
client.The detailed procedures are as follows:
1. On the MML client, choose MML Commands > System Management > Software
Management > Version Management > Load Software Online. Then run a command
to load the host software. Select a BIOS (BIOS file) and specify the version number. Set
the Software type and Software version. You can click or press F9.
LOD SOFTWARE: SWT=BIOS, SV="BSC6000V900R003C01";
2. On the MML client, observe the load progress. After the load is complete, the load result
is displayed on the MML client.
3. If the returned message indicates that the software fails to be loaded on some certain
boards, repeat step 1 through step 2. Because incremental load is achieved, the system
reloads software to only the boards where software fails to be loaded. If several attempts
for loading the software to some boards are made but all the attempts fail, check the
reason why the loading fails and perform the corresponding processing.
4. After the load is complete, confirm that the level 2 BIOS of all the boards is upgraded to
the correct version. If the version of the level 2 BIOS is incorrect, the board may not be
started.
The method is as follows:
Issue 1.00 (2007-12-29)Huawei Proprietary and Confidential
Page 28 of 84
INTERNALUSE
HUAWEI BSC6000 V900R003
Upgrade Guide
Step 1 On the LMT, choose BSC Maintenance > Query Software > Query Board Version Information.
Step 2 In the displayed Query Board Version Information dialog box, click the Software and Hardware Information tab.
Step 3 On the Software and Hardware Information tab page, choose each subrack (except subrack 12) in the Subrack drop-down list box in turn.
Step 4 Click Query to check the Level 2 BIOS Version of all the boards so that the level 2 BIOS version is confirmed to be correct.
----End
NOTE
1. If the loading of the level 2 BIOS fails due to system power failure or board resetting,
repeat the loading steps after the related fault is rectified. After the loading, if the
activated board cannot be started normally, replace the board. You can use an internal
tool to upgrade the replaced board for later use. The level 2 BIOS must be upgraded
when the system is in stable running.
2. If a board fails to be started, the BIOS may roll back to BIOS0.If the rollback fails due
to the incompatible BIOS0, the board cannot be started. After the rollback of the BIOS
and the failed initiation, the fault cannot be rectified. The board must be replaced.
3. For the XPU board, if the BIOS is upgraded from a version earlier than 205 to version
205, the board may be reset or suspended abnormally after the BIOS upgrade and the board
restart. The reason is that one BUG exists in the BIOS (version 205) of the XPU. Therefore,
after the board is restarted, you must remove the XPU board, and then reinsert the powered-
off board regardless of whether the restart is successful.
4.5 Upgrading the LMT
NOTE
Before installing the later version, you need to exit the LMT in earlier version firstly if the
LMT is open. You can exit the LMT by choosing System > Exit.
Install the new version LMT reference to 《BSC6000 V900R003 LMT Administration Guide》.
Issue 1.00 (2007-12-29)Huawei Proprietary and Confidential
Page 29 of 84
INTERNALUSE
HUAWEI BSC6000 V900R003
Upgrade Guide
4.6 Upgrading the Configuration Data File
4.6.1 Upgrading the Configuration Data File
1. Application Scenario:
The configuration data before the upgrade can be used.
2. Software and Hardware Preparations:
One PC that is installed with the Windows2000 or WindowsXP operating system
and can log in to the GBAM through the network.
An LMT in later version is available.
3. Upgrade Procedure
Determine whether it is the external GBAM mode or internal GOMU mode after the
upgrade. If it is the external GBAM mode, choose GBAM when logging in to the
LMT in later version in offline mode. If it is the internal GOMU mode, choose
GOMU.
The offline logging in to the LMT is successful. On the LMT, choose
Configuration > Open Local Data File. In the displayed dialog box, choose the
file saved in Backing Up Data Configuration Files
Click Yes to perform data upgrade. Wait until a message box prompting that the
upgrade is successful is displayed, as shown in the following figure.
Issue 1.00 (2007-12-29)Huawei Proprietary and Confidential
Page 30 of 84
INTERNALUSE
HUAWEI BSC6000 V900R003
Upgrade Guide
Click OK.The configuration data file is upgraded.。
On the LMT, choose Configuration > Back Up > Back Up Local Data. Data can
be verified globally. If the verification fails, data cannot be backed up. The error
information is listed in the dialog box. You need to reconfigure data to meet the
verification rules. Then, choose Configuration > Back Up > Back Up Local Data
again. If the check is successful, choose a backup path and input the file name to
perform the backup. The default directory (LMT installation directory) for file
backup is \BSC6000V900R003C01\BackupCfgData.
CAUTION
The function of the SCU port switch in BSC6000V900R001 is different from that in
BSC6000V900R003. For the BSC6000V900R001, all the SCU ports are available without
configurations and the SCU port switch is only used to determine whether to report the port
alarm. For the BSC6000V900R003, the SCU port switch is the enabling switch of the port
and is bound with the alarm switch. Therefore, after the data upgrade from
BSC6000V900R001 to BSC6000V900R003 is complete, you should check the port
configurations of all the SCU boards. If a certain port is used, the switch corresponding to the
port should be enabled manually. If the port is not used, the switch should be disabled to avoid
possible alarms.
Issue 1.00 (2007-12-29)Huawei Proprietary and Confidential
Page 31 of 84
INTERNALUSE
HUAWEI BSC6000 V900R003
Upgrade Guide
4.6.2 Prepraring the Configuration Data File
1. Application Scenario:
The office is new and there is no original configuration data.
2. Software and Hardware Preparations:
One PC that is installed with the Windows2000 or WindowsXP operating system
and can log in to the GBAM through the network.
The LMT installation package matches the server software that is running on the
GBAM.
3. Operation procedure:
Install the LMT software on a PC. For details, refer to "Upgrading the LMT."
Start the LMT in offline mode.
Perform offline configurations on the LMT based on the data provided by the
customer.
After the configuration is complete, on the LMT, choose Configuration > Back Up
> Back Up Local Data to save data.
----End
4.7 Upgrading GBAM and Single GOMU
CAUTION
1、Power-on and power-off of the GOMU board: Slightly loosen the handles on the upper and
lower ends of the GOMU board without removing the board. The blue offline LED on the
panel flashes. Remove the GOMU board until the offline LED is on. Do not use reset or
shutdown button on the panel of the GOMU board to reset or power off the board.
Issue 1.00 (2007-12-29)Huawei Proprietary and Confidential
Page 32 of 84
INTERNALUSE
HUAWEI BSC6000 V900R003
Upgrade Guide
2、After the OMU is successfully upgraded, log in to the LMT using user name admin and
password admin. Determine whether to reset the password based on your requirement. After
section 4.9 "Restoring Data", all the user names and passwords are restored to the data before
the upgrade.
4.7.1 Operation Preparations
For the operation preparations, you need to check the current system as follows:
1. Use the putty tool and log in to the GBAM/GOMU as user root. The IP address indicates the IP address of the external network.
2. Check the time zone by running the date +%z command on the putty.
3. Check the time by running the date command on the putty.
----End
NOTE
In step 1, for the GOMU, the IP address of the external network indicates the IP address that is permanently occupied by the active OMU. The LMT/M2000 can connect with the OMU Core through this IP address.
Steps 2 and 3 are used to confirm the time zone and time of the current GBAM/GOMU.
Perform the upgrade only after the confirmation. If the time zone and time are incorrect,
perform the adjustment by referring to the BSC6000 V900R003 GOMU Management
Guide.
1. Stopping the OMU Software:
# omuctrl stop
Enter “y” or “yes”. The following diagram shows the stopping of the OMU software.
2. Uninstalling the Existing Software of the GBAM OMU
Issue 1.00 (2007-12-29)Huawei Proprietary and Confidential
Page 33 of 84
INTERNALUSE
HUAWEI BSC6000 V900R003
Upgrade Guide
Run the following command on putty to query the OMU software installed:
# rpm -q omu
Upgrading versions before B070 the command will returen two rpm
install record because of a known bug, so twice rpm uninstall operation is
needed.
Run the following command on putty to uninstall the OMU software:
# rpm -e omu-9.3.1-61
# rpm -e omu-9.3.1-62
在 putty 上输入命令
# omuctrl status
Run the following command on putty to check the running status of the OMU software:
3. Manually Deleting the Files not Uninstalled
To delete the /BSC6000/bscswm folder and all the subdirectories and files under the
/BSC6000/bscswm directory, run the following command on putty:
# rm /BSC6000/bscswm -R
To delete the subdirectories and all the files under the /BSC6000/data directory, run the
following command on putty:
# rm /BSC6000/data/* -R
NOTE
Keep all files in the install directory for version rollback.
Issue 1.00 (2007-12-29)Huawei Proprietary and Confidential
Page 34 of 84
INTERNALUSE
HUAWEI BSC6000 V900R003
Upgrade Guide
If there are other folders or files except data and install (if there are files under
the btsswm directory, the directory exists) under the BSC6000 directory,
confirm whether these folders or files are required. If required, back up them to
your local PC. Huawei recommends you to delete all the files irrelevant to the
version on the GBAM.
Ensure that all the files related to the old data are deleted before the upgrade. If
there are such files, the LMT cannot connect to the GBAM after the OMU
software is installed.
4.7.2 Upgrading the GBAM
Reference 《BSC6000 V900R003 GBAM Administration Guide》to install the new version
OMU software.
4.7.3 Upgrading the GOMU
Reference 《BSC6000 V900R003 GOMU Administration Guide》to install the new version
OMU software.
NOTE
If a single GOMU is connected through the IP address of the external network, the IP address
is released when you run the omuctrl stop command to stop the OMU software. Therefore,
you must ensure that the GOMU can be connected through the commissioning of the IP
address.
4.7.4 Verify OMU version
Use the upgraded LMT to log in to the OMU. The menu path is Help > About. View the
version information. Press Ctrl+Shift+F12 to query the information on the B version, which
is the current version.
Issue 1.00 (2007-12-29)Huawei Proprietary and Confidential
Page 35 of 84
INTERNALUSE
HUAWEI BSC6000 V900R003
Upgrade Guide
4.8 Upgrading Active/Standby GOMU
NOTE
During the upgrade of active/standby GOMU, if you run the omuctrl stop command, you
must not perform other operations until the implementation of the command is complete. You
must not press the CTRL+C buttons to terminate the implementation of the command.
Otherwise, the IP address of the external network may not be used for communication.
The following describes how the later version can be upgraded when the active/standby
GOMUs run normally. n general, you should upgrade the two GOMUs respectively and
always upgrade the current standby GOMU.
1. On the putty, connect the active OMU through the IP address of the external network.
2. Set the backup switch to forbidden state and view the status of the local end by running
the cd /BSC6000/bscswm/omuroot/daemon, ./omutool backup disable, and ./omutool
status commands.
3. Query the IP address of the peer end by running the ./omutool status -peer command.
# ./omutool status -peer
Issue 1.00 (2007-12-29)Huawei Proprietary and Confidential
Page 36 of 84
INTERNALUSE
HUAWEI BSC6000 V900R003
Upgrade Guide
NOTE
If the query fails, you can infer that the backup channel is faulty. Check whether the standby board is running. If the standby board is not running, you need to run it.
If the standby board is running, you can infer that the backup channel is faulty and upgrade
cannot be performed. You can contact the local Huawei office for technical support.
4. Check whether the time zone and time of the active board are correctly set by referring to
section 4.7.1 "Operation Preparations."
# date +%z
# date
5. If file/root/.ssh/known_hosts exist on active OMU borad, run the follow command
to delete it.
# rm -f /root/.ssh/known_hosts
6. Run the ssh command (ssh 192.168.10.123) to connect the standby board (the IP address
of the standby board is the IP address of the peer end described in step 3).
# ssh 192.168.10.123
If the GOMU was once replaced, you may see the following print information.
Issue 1.00 (2007-12-29)Huawei Proprietary and Confidential
Page 37 of 84
INTERNALUSE
HUAWEI BSC6000 V900R003
Upgrade Guide
Delete the /root/.ssh/known_hosts file, and then perform another connection.
7. Check whether the time zone and time of the standby board are consistent with those of
the active board. In case of inconsistency, perform adjustment by referring to section
4.7.1 "Operation Preparations."
# date +%z
# date
8. If file/root/.ssh/known_hosts exist on standby OMU borad, run the follow command
to delete it.
# rm -f /root/.ssh/known_hosts
9. Back up the earilier version install package, and copy the new version from actived
OMU board,do as follows:
# cd /BSC6000/install
# rm rpmbak -rf
# md rpmbak
Issue 1.00 (2007-12-29)Huawei Proprietary and Confidential
Page 38 of 84
INTERNALUSE
HUAWEI BSC6000 V900R003
Upgrade Guide
# mv * rpmbak/
scp 192.168.10.121:/BSC6000/install/* .
# To install OMU software on standby board, refer to sections in《BSC6000
V900R003 GOMUAdministration Guide》.
NOTE
The active and standby OMUs have different versions, so the newly started OMU Local on
the standby board is always reset.
10. After the OMU software of the standby board is started, run the exit command to quit the
connection and to return to the connection on the active OMU.
# exit
11. Check that the status of the switchover switch is ON.
# cd /BSC6000/bscswm/omuroot/daemon
# ./omutool setswap enable
# ./omutool status
The following figure is an example.
Issue 1.00 (2007-12-29)Huawei Proprietary and Confidential
Page 39 of 84
INTERNALUSE
HUAWEI BSC6000 V900R003
Upgrade Guide
12. Stop the running of the OMU software on the current active OMU by running the
omuctrl stop command. The fault switchover is caused. After the standby board
becomes active, the IP address of the external network is switched to the new active
OMU.
# omuctrl stop
According to the prompted message, input yes (case sensitive) to stop the operation of the
OMU software, and during the process, the putty is disconnected with the OMU. Wait for a
period of time and then ping the IP address of the external network again.
NOTE
If the upgraded GOMU cannot be started and the IP address of the external network cannot be
pinged, you can infer that the upgrade fails. Then contact the local Huawei office for technical
support.
13. After the IP address of the external network is pinged, run the ssh command to connect
the new standby board.
# ssh 192.168.10.121
# To install OMU software on standby board, refer to sections in《BSC6000
V900R003 GOMUAdministration Guide》.
Issue 1.00 (2007-12-29)Huawei Proprietary and Confidential
Page 40 of 84
INTERNALUSE
HUAWEI BSC6000 V900R003
Upgrade Guide
14. After the standby board is installed, run the exit command to return to the connection on
the active board. Turn on the backup switch by running the cd
NOTE
After the OMU is successfully upgraded, log in to the LMT using user name admin and
password admin. Determine whether to reset the password based on your requirement. After
section 4.9 "Data Restoration", all the user names and passwords are restored to the data
before the upgrade.
15. Verfy OMU version
Figure 4-1 Use the upgraded LMT to log in to the OMU. The menu path is Help > About. View the version information. Press Ctrl+Shift+F12 to query the information on the B version, which is the current version.
---End
4.9 Data Restoration
CAUTION
For the releases later than R3C01B060, the system performs a license check before the
recovery of data configurations.
Issue 1.00 (2007-12-29)Huawei Proprietary and Confidential
Page 41 of 84
INTERNALUSE
HUAWEI BSC6000 V900R003
Upgrade Guide
1. Log in to the LMT in later version, and then connect the LMT to the GBAM/GOMU.
2.On the LMT, configure the originating signaling points and the destination signaling
points online and configure the relation between signaling points for subrack 0 according
to the license file.
3.On the LMT,Select the software license file to download and activate. Follow the
wizard to complete the activation.
NOTE
Before downloading a license, check the length of the license file name. The length of the
license file name should not exceed 31 characters. The recommended license file name is in
BSC name_yyyymmdd.dat format (for example, AlexBsc1_20070201.dat). The license file
name must be unique. "BSC6000" and the serial number given from the license distribution
center are not contained in a BSC6000 license file name
Save the software license file to the root directory of the LMT software installation
in later version, that is, \Common\SWM\License.
On the LMT in later version, choose BSC Maintenance > Maintenance License >
Download License. Select the software license file to be downloaded. Follow the
wizard to complete the download. The wizard is shown as follows:
Issue 1.00 (2007-12-29)Huawei Proprietary and Confidential
Page 42 of 84
INTERNALUSE
HUAWEI BSC6000 V900R003
Upgrade Guide
To activate the license, choose BSC Maintenance > Maintenance License >
Activate License. Select the software license file to be activated. Follow the wizard
to complete the activation.The wizard is shown as follows:
4.On the LMT,Choose Configuration > Load and Restore.
5.On the LMT,Select the Restore with local file option button. Select a data file from the
File On Local list. The data file is the backup data file that is in described in "Backing Up
Data Configuration Files."
NOTE
Ensure that the files to be restored are installed in the \BSC6000V900R003C01\
BackupCfgData directory, which is the LMT installation directory. Only the files in this
directory can be displayed in the list.
Issue 1.00 (2007-12-29)Huawei Proprietary and Confidential
Page 43 of 84
INTERNALUSE
HUAWEI BSC6000 V900R003
Upgrade Guide
6. Click Execute. A dialog box for confirmation is displayed, as shown in the following
figure:
7. Click Yes. If the restoration is successful, a message box is displayed, as shown in the
following figure.
Issue 1.00 (2007-12-29)Huawei Proprietary and Confidential
Page 44 of 84
INTERNALUSE
HUAWEI BSC6000 V900R003
Upgrade Guide
8.After the data is reloaded, the system is reset and the LMT is disrupted. A message box is
displayed, as shown in the following figure.
If the restoration fails, you are prompted that the restoration is faulty.
----End
NOTE
During the upgrade, do not perform consistency check or synchronization.
The consistency check and synchronization function is used when the
system is running normally. The function is used to check the data
consistency between the OMU and the board. In case of inconsistency,
perform data synchronization to ensure the data consistency between the
OMU and the board.
Through step 3, you can select a valid data file and restore the data.
You can click Detail information to view the detailed information on the
data file.
Step 3 can be divided into two substeps: select Load file from local to GBAM, and then
select Restore with GBAM file.
After you perform step 4, the GBAM core process is reset automatically. For the description
of board reset, refer to section 4.10 "Upgrading Board Software." You need to exit the LMT
and log in to it again.
If the data file used for data restoration is the data file of the system before the upgrade, the
information such as user authorities and the password is retained.
Issue 1.00 (2007-12-29)Huawei Proprietary and Confidential
Page 45 of 84
INTERNALUSE
HUAWEI BSC6000 V900R003
Upgrade Guide
4.10 Upgrading Board Software
4.10.1 Preparations
1. Confirm that the hardware and software are normal.
The OMU software is successfully installed. The OMU and the boards run normally.
2. Confirm that the data configuration is correct.
Confirm that the configuration data is consistent with that provided by the operator. The load
control parameters of all the boards are Auto.
4.10.2 Procedures for the Upgrade
Use the putty tool to log in to the OMU, and then perform the following steps:
1. Access the upgrade progress directory by running the follow command.
# cd /BSC6000/bscswm/omuroot/upgrade
2. Obtain the IP address used in the upgrade progress on the local OMU by
running the follow command.
# ifconfig | grep 192.168.10
3. Run the follow command to reset a board (assume that the obtained IP address
is 192.168.10.121).
# ./rus_sendreboot.bin 192.168.10.121 80.0.1.129 80.0.1.193
Explanation: Three parameters should be carried in the rus_sendreboot.bin command
supplied in the upgrade progress.
The first one is the local IP address, and you can run the ifconfig | grep 192.168.10 command
to view the IP address used in the upgrade process. The second one is the IP address of the
SCU in slot 6 of the receive party. The third one is the IP address of the SCU in slot 7 of the
receive party.
Issue 1.00 (2007-12-29)Huawei Proprietary and Confidential
Page 46 of 84
INTERNALUSE
HUAWEI BSC6000 V900R003
Upgrade Guide
CAUTION
After you run the ifconfig | grep 192.168.10 command, two IP addresses are displayed,
which indicates that the configuration of IP addresses are exposed to risks. You need to
modify the debug IP address to non 192.168.10 network segment or delete the
redundant IP addresses.
4. Each board starts to be reset after 15 seconds. The reset board runs the
upgraded software version.
----End
4.10.3 Confirming the Board State
1. Log in to the LMT in later version, and then connect the LMT to the GBAM/GOMU.
2. Click the Progress Window icon . Several tabs that display the progress of different
objects are available at the bottom of the window.
3. Click the BSC Load Progress tab.
4. On the BSC Load Progress tab page, the subrack numbers and slot numbers of the
current loaded boards as well as the loading progress are displayed. When the loading
progress is 100%, check whether the boards on the BSC device panel are normal.
4.10.4 Exception Handling
If the load progress of a certain board is not displayed, this board is not started normally.
To handle it, do as follows:
1. Check whether the physical connections and the OMLs on the Ater interface are correct.
Issue 1.00 (2007-12-29)Huawei Proprietary and Confidential
Page 47 of 84
INTERNALUSE
HUAWEI BSC6000 V900R003
Upgrade Guide
For details, refer to the HUAWEI BSC6000 Base Station Controller Hardware Installation
Guide and the HUAWEI BSC6000 Base Station Controller LMT User Guide.
2. For the level 2 BIOS versions earlier than 105, the GEIUT/GOIUT on the Ater interface
in the remote subrack does not support optical transmission or satellite transmission. If
the Ater interface needs to use optical transmission or satellite transmission for
networking, upgrade the level 2 BIOS to version 105 or later versions. Otherwise, the
remote subrack may not be started. Method to avoid this problem: For optical
transmission mode, configure the OMLs on the Ater interface on ports 0 and 62. After
the board in the remote subrack is started, upgrade the level 2 BIOS to version 105. If
this method cannot be used or if the remote links are in satellite transmission, the Ater
interface board in the remote subrack must use the board where the level 2 BIOS version
is 105, so that the board in the remote subrack can be started after the later version is
activated.
3. If the operating status of a board on the LMT is abnormal, choose Alarm Maintenance
> Browse Alarm to check whether the loading board software failed alarms (ID: 21019)
are reported.
If there are such alarms, refer to the BSC6000 Alarm Handling on the BSS Help System
window to handle them.
4. If a board is faulty, restart it or replace it. If the problem persists, contact the local
Huawei office for technical support.
----End
4.11 Activating the Software License
1. To activate the license, choose BSC Maintenance > Maintenance License > Activate
License. Select the software license file to be activated. Follow the wizard to complete
the activation.The wizard is shown as follows:
Issue 1.00 (2007-12-29)Huawei Proprietary and Confidential
Page 48 of 84
INTERNALUSE
HUAWEI BSC6000 V900R003
Upgrade Guide
2. To query the license, choose BSC Maintenance > Maintenance License > Query
License. Click Query. Fill the viewed configuration information into the Before the
Upgrade column in Appendix F "Checklist for the Configuration Information on
License Files."
NOTE
The software license is not delivered with the version. You have to apply for it from Huawei.
Issue 1.00 (2007-12-29)Huawei Proprietary and Confidential
Page 49 of 84
INTERNALUSE
HUAWEI BSC6000 V900R003
Upgrade Guide
5 Installing the M2000 Adaptation
Layer
Install M2000 Adaptation Layer reference to 《M2000 Adaptation Version Installation Guide(Only
for M2000 R6 Common Version)》.
6 Remote Upgrade Operations
NOTE
1、 The remote upgrade on the M2000 indicates the integrated upgrade, which contains
the upgrade of OMUDaemon, OMUCore, OMULocal, and SMU.
2、 Remote upgrade on the M2000 applies to only the upgrade of a version after
BSC6000V900R003C01.
3、Do install the M2000 adaptation layer of new version, otherwise, M2000 will not
connect to NE again after OMU software being upgraded. Subsequent commands
will not be executed and upgrade will fail.
Issue 1.00 (2007-12-29)Huawei Proprietary and Confidential
Page 50 of 84
INTERNALUSE
HUAWEI BSC6000 V900R003
Upgrade Guide
4、During the upgrade, do not change the OMU time, otherwise, the upgrade may fail
due to overtime.
6.1 Preparations
1. For the preparation for the software require in the upgrade, refer to section 3.4 "Required
Software in the Preparations for upgrade."
2. For the backup of the configuration data files of the BSC6000 equipment before the
upgrade, refer to section 4.2 "Backing Up Data Configuration Files."
3. For the generation of the configuration data files in later version, refer to section 4.6
"Upgrading the Configuration Data File." You need to save the configuration data files in
later version as lmt.dat for later use in the subsequent upgrade.
6.2 Procedures for the Upgrade
6.2.1 Creating the NE Objects
On the iManager M2000 Mobile Element Management System window, create the NE objects based on
the following steps:
Step 1 Right-click the iManager M2000 Mobile Element Management System window and choose Create Topo Object on the shortcut menu.
Step 2 The IP address is the external IP address of NEs. The Name is an NE name set by a user. Click OK. Assume that the NE name is BSC6000B022, which is used to identify NEs in subsequent operations.
Step 3 Click OK.
---End
6.2.2 Uploading Software and Data
Step 1 Copy the upgrade package (containing omu-9.3.x-yy.i586.rpm and boardfile.9.3.x.yy.zip), the version configuration table (verpkg.xml) of the upgrade package, the XML files for flow control (upgradecfg.xml) required by the M2000, and the version configuration table
Issue 1.00 (2007-12-29)Huawei Proprietary and Confidential
Page 51 of 84
INTERNALUSE
HUAWEI BSC6000 V900R003
Upgrade Guide
(vercfg.xml) that contains the information on the previous four types of files to the local hard disk of a PC where the M2000 client runs, for example, E:\upgradepkg.
Step 2 Copy the data file lmt.dat in later version to the local hard disk of a PC where the M2000 client runs, for example, E:\data. The file name must be lmt.dat.
Step 3 Upload software and data.
Choose Software > File Transfer Wizard/.
In the Direction drop-down list box, choose From GUI To Server.
In the Server Path drop-down list box, choose BSC6000 > Software to upload the
software in upgrade package. Choose BSC6000 > data > BSC6000B022 to upload
data
Select the path where the uploaded file is contained. Click Finish to perform the
upload.
Observe the progress to wait for the completion of the upload.
----End
6.2.3 Performing the Upgrade
The upgrade is performed as follows:
Step 1 Choose Software > NE Upgrade Wizard > Upgrade BSC6000. Then, choose BSC6000B022 and click OK.
Step 2 Select the version to be upgraded. Click Next.
Step 3 On the BSC6000 Upgrade Wizard dialog box, click Next to perform the upgrade. Observe the progress and result of each step.
---END
In the Upgrade Execution step, complete the upgrade of OMUDaemon, OMUCore,
OMULocal, and boards.
If you do not upgrade the OMU in remote upgrade mode, click Exit to exit the upgrade.
Then, perform the upgrade based on the operation methods described in the previous sections.
The following steps are displayed In the BSC6000 Upgrade Wizard dialog box:
Select Upgrade Version is used to select the version to be upgraded.
The user selects the correct version to perform the upgrade.
Download Software is used to download software.
Issue 1.00 (2007-12-29)Huawei Proprietary and Confidential
Page 52 of 84
INTERNALUSE
HUAWEI BSC6000 V900R003
Upgrade Guide
This step can be skipped, however, you are advised not to skip it. If you are sure that the
software in the version to be upgrade is successfully downloaded, the step can be skipped.
Otherwise, the upgrade cannot be performed.
If the previous upgrade is not complete or is abnormal, the upgrade progress is not closed. Thus, the
software fails to be downloaded. The human interference on the local end is necessary.
Download New Version Data is used to download the data in later version.
If you are sure that the data in the version to be upgraded is downloaded, the step can be
skipped. If such data is not downloaded, but you skip the step, the upgrade fails.
Load Software and BIOS is used to load software and BIOS.
In the step, the host software and level 2 BIOS are loaded online. In other words, Loading the
Host Software Online described in section 4.3 and Loading the Level 2 BIOS to a Board
Online described in 4.4 are complete in the step.]
In the BSC6000 Upgrade Wizard dialog box, you can observe the load progress and result.
If the load fails, repeat the step. Because incremental load is achieved, the system reloads
software to only the boards where software fails to be loaded.
If several attempts for loading the software to some boards are made but all the attempts fail,
only the human interface on the local end works. Then, check the reason why the loading fails
and perform the corresponding processing.
Upgrade Execution is used to perform the upgrade.
The upgrade of the OMU and the activation of a board are contained in this step. In the
BSC6000 Upgrade Wizard dialog box, you can observe the load progress and result.
If the upgrade incurs an error, the First, Retry, and Rollback buttons are displayed in the
BSC6000 Upgrade Wizard dialog box.
Click First. The whole process of the upgrade can be performed again.
Click Retry. The upgrade continues to be performed from the point where the error occurs.
You are advised to click Retry when an error occurs.
Click Rollback. The system is rolled back to the version before the upgrade. After the
rollback, if you need to perform the upgrade again, restart the BSC6000 Upgrade Wizard.
You need to perform the upgrade from the Select Upgrade Version step.
Issue 1.00 (2007-12-29)Huawei Proprietary and Confidential
Page 53 of 84
INTERNALUSE
HUAWEI BSC6000 V900R003
Upgrade Guide
The activation of a board requires your confirmation. When you perform this step, the
Confirm and Rollback buttons are displayed in the BSC6000 Upgrade Wizard dialog box.
Click Confirm. The board is reset and the version is upgraded to a new one.
Click Rollback. The system is rolled back to the version before the upgrade.
After the rollback, if you need to perform the upgrade again, restart the BSC6000 Upgrade
Wizard. You need to perform the upgrade from the Select Upgrade Version step.
Upgrade Submission is used to submit the upgrade.
If there are active and standby OMUs, you need to upgrade the standby OMU. If the standby
OMU is faulty, the step fails. The human interference on the local end is necessary.
Upgrade Rollback is used to roll back the upgrade.
If the rollback fails, the First and Exit buttons are displayed in the BSC6000 Upgrade
Wizard dialog box.
Click First. The rollback is performed again. If several attempts for the rollback are
made but all the attempts fail, click Exit to exit the BSC6000 Upgrade Wizard
dialog box. The human interference on the local end is necessary.
6.2.4 Download and Activate License
To download and activate the license, do as follows:
Step 1 Prepare the license file.
Refer to section 3.5 "Preparing the License." Copy the license file to the local hard disk of a
PC where the M2000 client runs, for example E:\license.
Step 2 Upload the license file.
Refer to section 6.2.2 "Uploading Software and Data." Click License.
Step 3 Download and activate the license.
Choose Software > Browser. The iManager M2000 Mobile Element
Management System window is displayed as follows:
Issue 1.00 (2007-12-29)Huawei Proprietary and Confidential
Page 54 of 84
INTERNALUSE
HUAWEI BSC6000 V900R003
Upgrade Guide
Click License.
Click Download From Server to download the license.
Click Show License Detail to view the license information.
Click Activate to activate the license.
Issue 1.00 (2007-12-29)Huawei Proprietary and Confidential
Page 55 of 84
INTERNALUSE
HUAWEI BSC6000 V900R003
Upgrade Guide
7 Upgrade Verification
7.1 Verification Checklist
Table 7-1 Checklist for the verification items
No. Verification Item Requirement No.
1 Verification after the
upgrade
Use the checklist for the system
health to check that the verification
items are correct.
1
2 Site cleanup after the
upgrade
Clean up the site 2
7.2 Verification After the Upgrade
You need to perform the verification by referring to the following checklist. If you find any
abnormal situation, record it in detail.
1. Checking the version
Log in to the GBAM/GOMU through the LMT. The user name and the password
should be consistent with those defined in the data used for data restoration.
Issue 1.00 (2007-12-29)Huawei Proprietary and Confidential
Page 56 of 84
INTERNALUSE
HUAWEI BSC6000 V900R003
Upgrade Guide
On the LMT, choose Help > About. Press Ctrl+Shift+F12 to check the current
LMT version.
On the LMT, choose Help > About. Press Ctrl+Shift+F12 to check the current
GBAM/GOMU version.
On the LMT, choose BSC Maintenance > Query Software > Query Board
Version Information. Set the filtering conditions for the corresponding board. On
the Software and Hardware Information tab page, click Query. Press
Ctrl+Shift+F12 to check the software version of each board.
----End
2. Checking the Running of Tools
Check whether the LMT runs normally.
Check whether the alarms and traffic statistics can be viewed on the M2000 (The
performance measurement results are correctly reported to the M2000).
Check whether the configuration data is consistent with that before the upgrade.
----End
3. Checking the Operating Status of NEs
Check that there is no abnormality alarm on the LMT or on the M2000.
On the LMT, choose BSC Maintenance > Maintain Device > Query BSC Board
Clock State and BSC Maintenance > Maintain Device > Query BSC Board
Reference State to check the system clock status, board clock status, and BTS clock
status (fast pull-in or locked).
On the LMT, choose BSC Maintenance > Maintain Transmission and Signaling
> Maintain SCCP to check whether all the links on the A interface are normal.
On the LMT, choose BSC Maintenance > Maintain Transmission and Signaling
> Maintain LAPD Link to check whether all the LAPD links are normal.
On the LMT, choose BTS Maintenance to check whether the BTS software
versions, BTS board status, and TRX channel status are normal
On the LMT, choose BSC Maintenance > Maintain Transmission and Signaling
to check whether the E1 port is normal.
Issue 1.00 (2007-12-29)Huawei Proprietary and Confidential
Page 57 of 84
INTERNALUSE
HUAWEI BSC6000 V900R003
Upgrade Guide
On the LMT, choose BSC Maintenance > Maintain User Resource to check
whether all the CICs, PCICs, Abis timeslots, Ater timeslots, and TC resources are
normal.
After the GMPS is running for 21 minutes, choose Alarm Maintenance > Browse
Alarm to check that there are no License block alarms about BTSs, cells, or TRXs.
4. Checking the Services
Basic call procedure test: On the LMT, use an MS to call another MS or a fixed-line
phone. Perform the interface tracing function of the LMT to check whether the
location update procedure and the whole signaling transmission procedure are
complete. In addition, the conversation quality can be viewed on the LMT.
The traffic statistics counters on the M2000 are normal.
The analysis shows that the logs are normal: CHR, TC-CHR (The symptoms, such
as one-way audio and no audio do not occur), running log, and debug log (browsing
only).
Make test calls. For details, refer to the information on dialing tests.
NOTE
For detailed information on system health check after the upgrade, refer to Appendix E
"Checklist for System Health After the Upgrade."
7.3 Completing the Upgrade
7.3.1 Sanitation in the Environment After the Upgrade
Succeeds
1. If no errors occur one week after the upgrade, clean up the site.
After the upgrade, dispose of the sundries and ensure that the equipment room is
clean and tidy.
Remove the redundant materials.
Sort the data (such as files) generated during the upgrade.
Issue 1.00 (2007-12-29)Huawei Proprietary and Confidential
Page 58 of 84
INTERNALUSE
HUAWEI BSC6000 V900R003
Upgrade Guide
2. If errors are detected during verification and the errors cannot be rectified, roll back the
version to restore system services to normal. For details, refer to Version Rollback
Issue 1.00 (2007-12-29)Huawei Proprietary and Confidential
Page 59 of 84
INTERNALUSE
HUAWEI BSC6000 V900R003
Upgrade Guide
8 Version Rollback
CAUTION
Version rollback is performed only when the version verification indicates that the upgrade fails. For details of failure handling, refer to the troubleshooting part in the operation procedure.
The current level 2 BIOS is compatible with the host software in earlier version. Therefore, you do not need to roll back level 2 BIOS during the version rollback.
8.1 Precautions
8.2 Rollbacking OMU Software
The OMU software in earlier version is installed as follows:
1. Log in to the GBAM/GOMU as user root.
2. Shutdown the omu by input follow command:
# omuctrl stop
Issue 1.00 (2007-12-29)Huawei Proprietary and Confidential
Page 60 of 84
INTERNALUSE
HUAWEI BSC6000 V900R003
Upgrade Guide
3. Uninstall the OMU software on the GBAM/GOMU. Then, run the follow command on
putty.
# rpm -e omu
4. Use the putty tool to manually delete the files that are not uninstalled.
NOTE
Because the data directory is associated to the partition during the installation of the operating system, the data directory cannot be deleted.
Keep the install directory and the files in it for version rollback.
If the btsswm directory exists, do not delete it. If you need to delete it, ensure that the files in this directory are backed up to the local hard disk or these files are not used in later version.
If the following folders to be deleted do not exist in the /BSC6000 directory, you do not have to run the following commands.
a) Delete a specified directory and its subdirectories and files in the /BSC6000 directory.
Delete the /BSC6000/bscswm directory and all the subdirectories and files in the
/BSC6000/bscswm directory, run the follow command on putty.
# rm -R /BSC6000/bscswm
Delete the subdirectories and all the files in the /BSC6000/data directory, run the follow
command on putty.
# rm -R /BSC6000/data/*
b) Check after the deletion.
Run the follow command on putty to access the /BSC6000 directory.
# cd /BSC6000
Run the ls command on putty to confirm that there is no bscswm subdirectory in the
/BSC6000 directory.
# ls
Run the cd data command on putty to access the data directory.
# cd data
Issue 1.00 (2007-12-29)Huawei Proprietary and Confidential
Page 61 of 84
INTERNALUSE
HUAWEI BSC6000 V900R003
Upgrade Guide
Run the ls command on putty to confirm that there is no subdirectory or file in the data
directory.
# ls
5. Install the OMU softear of earilier version reference to 《BSC6000 V900R003 GOMU
Administration Guide》or 《BSC6000 V900R003 GBAM Administration Guide》in actual
situation.
8.3 Restore old data and old board software
1. Log in to the GBAM/GOMU as user root to set the authority of the /BSC6000 by
running the follow command:
# chmod 777 /BSC6000 -R
2. Restore old data.
Copy all the files backed up in the data/ folder to the directory /BSC6000/data through
samba. For detailed backup method, refer to "Backing Up Data." Overwrite the existing
folders, as shown in the following figure:
3. Restore the old board software.
Change the name of the bscswmb0xx directory that is backed up to a local hard disk into
bscswm and copy it to the /BSC6000 directory through the Samba. Overwrite the existing
folders, as shown in the following figure:
Issue 1.00 (2007-12-29)Huawei Proprietary and Confidential
Page 62 of 84
INTERNALUSE
HUAWEI BSC6000 V900R003
Upgrade Guide
4. Restore the authority control by running the follow commands.
# chown root /BSC6000 -R
# chmod 755 /BSC6000 -R
8.4 Starting the OMU Software
1. To start the OMU software process on the GBAM/GOMU by running the follow
command on putty.
# omuctrl start
2. To view the operating status of the OMU software on the GBAM/GOMU by running the
follow command on putty.
# omuctrl status
8.5 Rolling Back Board Software
1. Reset the entire system by running the follow commands:
# cd /BSC6000/bscswm/omuroot/upgrade
# ifconfig | grep 192.168.10
# ./rus_sendreboot.bin 192.168.10.121 80.0.1.129 80.0.1.193
2. Monitor the board loading status until the all the boards are operational.
Issue 1.00 (2007-12-29)Huawei Proprietary and Confidential
Page 63 of 84
INTERNALUSE
HUAWEI BSC6000 V900R003
Upgrade Guide
Log in to the GBAM/GOMU through the LMT. Click the Progress Window icon .
Several tabs that display the progress of different objects are available at the bottom of the
window. Click the BSC Load Progress tab. On the BSC Load Progress tab page, the
subrack numbers and slot numbers of the current loaded boards as well as the loading
progress are displayed. When the loading progress is 100%, check whether the boards on the
BSC device panel are normal.
The following figure shows the progress window.
NOTE
If no loading progress is displayed after you log in to the GBAM through the LMT in later version, check whether the out-of-synchronization alarm is generated by choosing Alarm Maintenance > Browse Alarm on the BSC6000 Local Maintenance Terminal.
If the out-of-synchronization alarm is generated, reset all the subracks by choosing BSC Maintenance > Maintenance Device > Reset Subrack on the BSC6000 Local Maintenance Terminal.
8.6 Rolling back LMT
Uninstall the new version LMT, and install the earilier version LMT refer to its upgrade instructions.
8.7 Verification
For details, refer to "Checking the version" described in "Verification After the Upgrade."
Issue 1.00 (2007-12-29)Huawei Proprietary and Confidential
Page 64 of 84
INTERNALUSE
HUAWEI BSC6000 V900R003
Upgrade Guide
9 FAQ
9.1 FAQ Index
Table 9-1 FAQ list
Number Description Reference
FAQ1
What you should pay attention to
when installing the LMT in
version B or version SP?
9.2 FAQ1
Description:
What you should pay attention to when installing the LMT in version B or version SP?
Reply:
To upgrade the LMT from version B to version SP, back up the installation directory of
version B, because version SP may replace version B.
Issue 1.00 (2007-12-29)Huawei Proprietary and Confidential
Page 65 of 84
INTERNALUSE
HUAWEI BSC6000 V900R003
Upgrade Guide
A Upgrade Preparations
Item Description Remarks
Name of the device to be
upgraded
Place where the device to
be upgraded is located
Permitted upgrade date
and time
Upgrade the device when the
traffic volume is low
Customer's requirements
for the upgrade
Version before the
upgrade
BIOS version
Host software version
Patch information
Version after the upgrade
BIOS version
Issue 1.00 (2007-12-29)Huawei Proprietary and Confidential
Page 66 of 84
INTERNALUSE
HUAWEI BSC6000 V900R003
Upgrade Guide
Item Description Remarks
Host software version
Patch information
Requirements for the
versions of other NEs
Software required for the
upgrade
Data required for the
upgrade
If the configuration data remains
unchanged, you do not have to
prepare the data.
Hardware materials
required for the upgrade
If the hardware does not change
during the upgrade, you do not
have to prepare hardware
materials.
Tools required for the
upgrade
Special tools for the upgrade,
mobile equipment, SIM card, and
Ethernet cables
Upgrade personnelPersonnel from both the customer
and Huawei
Assistants
Maintenance personnel of other
NEs and network planning
personnel
VehicleVehicles are required for drive
test, if any.
Contact personName and telephone number of
the contact person
Issue 1.00 (2007-12-29)Huawei Proprietary and Confidential
Page 67 of 84
INTERNALUSE
HUAWEI BSC6000 V900R003
Upgrade Guide
B Upgrade Record
Site Name Upgrade Time
Version before
the upgrade
Version after the
upgrade
Upgrade
personnel
From the customer:
From Huawei:
Success or
failure
Operation Item Conclusion Troubleshooting
Check of the
operating status
before the
upgrade
Multiple IP addresses
Remote links
Current alarm
information
Cell status
Data consistency
Upgrade
procedures
Back up data
Download all the files
related to the current
version
Issue 1.00 (2007-12-29)Huawei Proprietary and Confidential
Page 68 of 84
INTERNALUSE
HUAWEI BSC6000 V900R003
Upgrade Guide
Upload the OMU
software installation
disk to the
GBAM/GOMU
Install the OMU
software onto the
GBAM/GOMU
Install the matching
version of the M2000
(server, client, and
adaptation layer)
Upgrade the matching
BTS version
Install the matching
LMT
Verification
after the
upgrade
Check current alarm
information
Check link status
Check versions
Make test calls
Issue 1.00 (2007-12-29)Huawei Proprietary and Confidential
Page 69 of 84
INTERNALUSE
HUAWEI BSC6000 V900R003
Upgrade Guide
C Checklist for Dialing Test
BTS Name
Test Time
Conclusion □Pass □Not Pass
Cell Name
Cell ID
main BCCH Frequency
Network Color Code (NCC)
BTS Color Code (BCC)
Test Item Test Result 备注
Speech: fixed-line phone
calling MS (GSM)
□Pass □NotPass □N/A
Speech: MS (GSM) calling
fixed-line phone
□Pass □NotPass □N/A
Speech: MS (GSM) calling
MS (GPRS)
□Pass □NotPass □N/A
Speech: MS (GPRS) calling
MS (GSM)
□Pass □NotPass □N/A
Issue 1.00 (2007-12-29)Huawei Proprietary and Confidential
Page 70 of 84
INTERNALUSE
HUAWEI BSC6000 V900R003
Upgrade Guide
Speech: MS (GSM) calling
MS (GSM)
□Pass □NotPass □N/A
VP: MS (GSM) calling MS
(GSM)
□Pass □NotPass □N/A
PS: PDP activation □Pass □NotPass □N/A
Conversation quality of
speech
□Good □Bad □N/A
Conversation quality of VP □Good □Bad □N/A
Communication quality of PS □Good □Bad □N/A
Call drop □Pass □NotPass □N/A
Soft handover □Pass □NotPass □N/A
RSCP (should be greater than
-70 dBm)
Ec/I0(should be greater than -
10 dB)
Signature of test personnel
Issue 1.00 (2007-12-29)Huawei Proprietary and Confidential
Page 71 of 84
INTERNALUSE
HUAWEI BSC6000 V900R003
Upgrade Guide
D Checklist for System Health
Before the Upgrade
Checklist for the state of each interface
SN SN SN SN
1. 1. 1. 1.
2. 2. 2. 2.
3. 3. 3. 3.
4. 4. 4. 4.
5. 5. 5. 5.
6. 6. 6. 6.
7. 7. 7. 7.
8. 8. 8. 8.
Tested by: Tested by:
Checklist for the operating status of the BTS
SN SN SN SN
Issue 1.00 (2007-12-29)Huawei Proprietary and Confidential
Page 72 of 84
INTERNALUSE
HUAWEI BSC6000 V900R003
Upgrade Guide
1. 1. 1. 1.
2. 2. 2. 2.
3. 3. 3. 3.
Tested by: Tested by:
Checklist for operating status of boards
SN SN SN SN
1. 1. 1. 1.
2. 2. 2. 2.
3. 3. 3. 3.
4. 4. 4. 4.
5. 5. 5. 5.
Tested by: Tested by:
Checklist for Alarm Information
SN SN SN SN
1. 1. 1. 1.
2. 2. 2. 2.
3. 3. 3. 3.
4. 4. 4. 4.
5. 5. 5. 5.
6. 6. 6. 6.
Tested by: Tested by:
Issue 1.00 (2007-12-29)Huawei Proprietary and Confidential
Page 73 of 84
INTERNALUSE
HUAWEI BSC6000 V900R003
Upgrade Guide
Checklist for the M2000 Traffic Statistics Counters
SN SN SN SN
1. 1. 1. 1.
2. 2. 2. 2.
3. 3. 3. 3.
4. 4. 4. 4.
5. 5. 5. 5.
6. 6. 6. 6.
7. 7. 7. 7.
8. 8. 8. 8.
9. 9. 9. 9.
10. 10. 10. 10.
Tested by: Tested by:
Checklist for the Operating Status of the GBAM/GOMU
SN SN SN SN
1. 1. 1. 1.
2. 2. 2. 2.
3. 3. 3. 3.
4. 4. 4. 4.
Tested by: Tested by:
Issue 1.00 (2007-12-29)Huawei Proprietary and Confidential
Page 74 of 84
INTERNALUSE
HUAWEI BSC6000 V900R003
Upgrade Guide
E Checklist for System Health
After the Upgrade
Checklist for Clock Status
SN SN SN SN
1. 1. 1. 1.
2. 2. 2. 2.
3. 3. 3. 3.
4. 4. 4. 4.
5. 5. 5. 5.
6. 6. 6. 6.
Tested by: Tested by:
Checklist for the state of each interface
SN SN SN SN
1. 1. 1. 1.
2. 2. 2. 2.
3. 3. 3. 3.
4. 4. 4. 4.
5. 5. 5. 5.
Issue 1.00 (2007-12-29)Huawei Proprietary and Confidential
Page 75 of 84
INTERNALUSE
HUAWEI BSC6000 V900R003
Upgrade Guide
6. 6. 6. 6.
7. 7. 7. 7.
8. 8. 8. 8.
9. 9. 9. 9.
Tested by: Tested by:
Checklist for the operating status of the BTS
SN SN SN SN
1. 1. 1. 1.
2. 2. 2. 2.
3. 3. 3. 3.
Tested by: Tested by:
Checklist for operating status of boards
SN SN SN SN
1. 1. 1. 1.
2. 2. 2. 2.
3. 3. 3. 3.
4. 4. 4. 4.
5. 5. 5. 5.
6. 6. 6. 6.
Tested by: Tested by:
Checklist for Alarm Information
SN SN SN SN
1. 1. 1. 1.
Issue 1.00 (2007-12-29)Huawei Proprietary and Confidential
Page 76 of 84
INTERNALUSE
HUAWEI BSC6000 V900R003
Upgrade Guide
2. 2. 2. 2.
3. 3. 3. 3.
4. 4. 4. 4.
5. 5. 5. 5.
Tested by: Tested by:
Checklist for the M2000 Traffic Statistics Counters
SN SN SN SN
1. 1. 1. 1.
2. 2. 2. 2.
3. 3. 3. 3.
4. 4. 4. 4.
5. 5. 5. 5.
6. 6. 6. 6.
7. 7. 7. 7.
8. 8. 8. 8.
9. 9. 9. 9.
10. 10. 10. 10.
Tested by: Tested by:
Checklist for the Operating Status of the GBAM/GOMU
SN SN SN SN
1. 1. 1. 1.
2. 2. 2. 2.
3. 3. 3. 3.
4. 4. 4. 4.
Issue 1.00 (2007-12-29)Huawei Proprietary and Confidential
Page 77 of 84
INTERNALUSE
HUAWEI BSC6000 V900R003
Upgrade Guide
Tested by: Tested by:
Checklist for Basic Service Test
SN SN SN SN
1. 1. 1. 1.
Tested by: Tested by:
Checklist for Call Service Test
SN SN SN SN
1. 1. 1. 1.
2. 2. 2. 2.
3. 3. 3. 3.
4. 4. 4. 4.
Tested by: Tested by:
Checklist for SMS Service Test
SN SN SN SN
1. 1. 1. 1.
Tested by: Tested by:
Checklist for Handover Service Test
SN SN SN SN
1. 1. 1. 1.
2. 2. 2. 2.
3. 3. 3. 3.
Tested by: Tested by:
Checklist for RBT Service Test (Optional)
SN SN SN SN
Issue 1.00 (2007-12-29)Huawei Proprietary and Confidential
Page 78 of 84
INTERNALUSE
HUAWEI BSC6000 V900R003
Upgrade Guide
1. 1. 1. 1.
Tested by: Tested by:
Checklist for Fax Service Test (Optional)
SN SN SN SN
1. 1. 1. 1.
Tested by: Tested by:
Checklist for Prepaid Service Test (Optional)
SN SN SN SN
1. 1. 1. 1.
Tested by: Tested by:
Checklist for Emergency Call Service Test
SN SN SN SN
1. 1. 1. 1.
Tested by: Tested by:
Checklist for Two-Stage Dialing Service (Optional)
SN SN SN SN
1. 1. 1. 1.
Tested by: Tested by:
Checklist for Recharge Service Test (Optional)
SN SN SN SN
1. 1. 1. 1.
Tested by: Tested by:
Issue 1.00 (2007-12-29)Huawei Proprietary and Confidential
Page 79 of 84
INTERNALUSE
HUAWEI BSC6000 V900R003
Upgrade Guide
F Checklist for the Configuration
Information on License Files
Item Before the
Upgrade
After the
Upgrade
End date
ESN information
Maximum TRX number allowed
Number of the TRX supporting half-
rate
Number of the TRX supporting AMR
Number of the TRX supporting
EDGE
Number of semipermanent connection
Number of the cell supporting
broadcasting short message service
Number of the site supporting satellite
transmission
Number of the extended cell
Number of DTRU which Transmitter
is PBT
Issue 1.00 (2007-12-29)Huawei Proprietary and Confidential
Page 80 of 84
INTERNALUSE
HUAWEI BSC6000 V900R003
Upgrade Guide
Number of DTRU which Transmitter
is Diversity Transmitter
Number of DTRU which works as
Dual Transceiver
Number of DTRU which Receiver is
Four Diversity Receiver
Number of high output power TRU
Whether to activate the eMLPP
function or not
Whether to activate the LCS(CELL
ID+TA) function or not
Whether to activate intersystem handover & reselection
Whether or not to activate the
Channel Reserved function
G Acronyms and Abbreviations
Abbreviations Full spelling
BSC Base Station Controller
LMT Local Maintenance Terminal
Issue 1.00 (2007-12-29)Huawei Proprietary and Confidential
Page 81 of 84
INTERNALUSE
HUAWEI BSC6000 V900R003
Upgrade Guide
Abbreviations Full spelling
M2000 Imanager 2000
GBAM GSM Back Administration
Module
GOMU GSM Operation and
Maintenance Unit
RSL Radio Signaling Link
OML Operation and Maintenance
Link
GMPS GSM Main Processing Subrack
GSM
GEPS GSM Extended Processing
Subrack
GTCS GSM TransCoder Subrack
GEIUA GSM E1/T1 Interface Unit for
A
GEIUB GSM E1/T1 Interface Unit for
Abis
GEIUT GSM E1/T1 Interface Unit for
Ater
GEIUP GSM E1/T1 Interface Unit for
Pb
GOIUA GSM Optic Interface Unit for
A
GOIUB GSM Optic Interface Unit for
Abis
GOIUT GSM Optic Interface Unit for
Issue 1.00 (2007-12-29)Huawei Proprietary and Confidential
Page 82 of 84
INTERNALUSE
HUAWEI BSC6000 V900R003
Upgrade Guide
Abbreviations Full spelling
Ater
GOIUP GSM Optic Interface Unit for
Pb
GXPUM GSM eXternded Processing
Unit for Main service
GXPUC GSM eXternded Processing
Unit for Cell Broadcast service
GSCU GSM Switching and Control
Unit
GTNU GSM TDM Switching Unit
GGCU GSM General clocK Unit
GUI Graphic User Interface
SCCP Signaling Connection Control
Part
LAPD Link Access Procedure on the
D channel
CIC Circuit Identification Code
PCIC Packet Circuit Identity Code
TC Transcoder
CHR Call History Record
GPRS General Packet Radio Service
GSM Global System for Mobile
communications
GDPUC GSM Data Processing Unit for
CS service
DTRU Double-Transceiver Unit
Issue 1.00 (2007-12-29)Huawei Proprietary and Confidential
Page 83 of 84
INTERNALUSE
HUAWEI BSC6000 V900R003
Upgrade Guide
Abbreviations Full spelling
ESN Electronic Serial Number
Issue 1.00 (2007-12-29)Huawei Proprietary and Confidential