OceanStor 5300 V3&5500 V3&5600 V3&5800V3&6800 V3 Storage System

V300R002

Event Reference

Issue 04

Date 2015-06-10

HUAWEI TECHNOLOGIES CO., LTD.

Copyright © Huawei Technologies Co., Ltd. 2015. All rights reserved.

No part of this document may be reproduced or transmitted in any form or by any means without prior writtenconsent of Huawei Technologies Co., Ltd. Trademarks and Permissions

and other Huawei trademarks are trademarks of Huawei Technologies Co., Ltd.All other trademarks and trade names mentioned in this document are the property of their respective holders. NoticeThe purchased products, services and features are stipulated by the contract made between Huawei and thecustomer. All or part of the products, services and features described in this document may not be within thepurchase scope or the usage scope. Unless otherwise specified in the contract, all statements, information,and recommendations in this document are provided "AS IS" without warranties, guarantees or representationsof any kind, either express or implied.

The information in this document is subject to change without notice. Every effort has been made in thepreparation of this document to ensure accuracy of the contents, but all statements, information, andrecommendations in this document do not constitute a warranty of any kind, express or implied.

Huawei Technologies Co., Ltd.Address: Huawei Industrial Base

Bantian, LonggangShenzhen 518129People's Republic of China

Website: http://enterprise.huawei.com

Issue 04 (2015-06-10) Huawei Proprietary and ConfidentialCopyright © Huawei Technologies Co., Ltd.

i

About This Document

Intended AudienceThis document describes the basic knowledge about the events of storage system in terms ofevent definition, event level, impact on the system, possible cause, and handling procedure.

This document is intended for:

l Technical support engineersl Maintenance engineers

Content ConventionsThe purchased products, services, and features are stipulated by the commercial contract madebetween Huawei and the customer. All or partial products, services and features described inthis document may not be within the purchased scope or the usage scope. Unless otherwiseagreed by the contract, all statements, information, and recommendations in this document areprovided "AS IS" without warranties, guarantees, or representations of any kind, either expressor implied

As part of an effort to improve and enhance the performance and capabilities of its product line,Huawei Technologies Co., Ltd. from time to time releases revisions of its hardware and software.Therefore, some functions described in this manual may not be supported by all revisions of thesoftware or hardware currently in use. For the most up-to-date information on product features,refer to your product release notes.

If a product does not function as described in this manual, please contact your HuaweiTechnologies Co., Ltd. technical support.

Change HistoryChanges between document issues are cumulative. The latest document issue contains all thechanges made in earlier issues.

Issue 04 (2015-06-10)Fourth official release.

OceanStor 5300 V3&5500 V3&5600 V3&5800 V3&6800V3 Storage SystemEvent Reference About This Document

Issue 04 (2015-06-10) Huawei Proprietary and ConfidentialCopyright © Huawei Technologies Co., Ltd.

ii

New events are included and some events are modified.

Issue 03 (2015-03-13)Third official release.

Added 5300 V3 and 6800 V3.

Issue 02 (2014-12-25)Second official release.

New events are included and some events are modified.

Issue 01 (2014-10-30)Initial official release.

OceanStor 5300 V3&5500 V3&5600 V3&5800 V3&6800V3 Storage SystemEvent Reference About This Document

Issue 04 (2015-06-10) Huawei Proprietary and ConfidentialCopyright © Huawei Technologies Co., Ltd.

iii

Contents

About This Document.....................................................................................................................ii

1 Overview.........................................................................................................................................1

2 Troubleshooting Events...............................................................................................................32.1 0xF0C90001 License Is About To Expire....................................................................................................................122.2 0xF0C90002 License Has Expired...............................................................................................................................122.3 0xF0C90003 Invalid License........................................................................................................................................132.4 0xF00C90015 Controller Write Cache Is Disabled......................................................................................................142.5 0xF0C90006 The System Has Entered Safe Mode......................................................................................................152.6 0x100F0C9000C Controller Failed To Be Powered On Again....................................................................................162.7 0x100F0C90065 System Engine Is Working In Single Controller State.....................................................................162.8 0xF0CE0001 Failed To Monitor A Disk Enclosure.....................................................................................................172.9 0xF0CE0002 Disk Enclosure Quantity Exceeds The System Limit............................................................................182.10 0xF0CE0004 Failed To Identify An Engine Or Disk Enclosure................................................................................192.11 0xF0CE0005 Disk Enclosure Temperature Exceeds The Upper Limit......................................................................202.12 0xF0CE000A Disk Enclosure Temperature Is Far Beyond The Upper Limit...........................................................212.13 0xF0CE0007 Engine Or Disk Enclosure Temperature Is Below The Lower Limit...................................................222.14 0xF0CE0008 Engine Temperature Exceeds The Upper Limit...................................................................................232.15 0xF0CE0009 Engine Temperature Is Far Beyond The Upper Limit.........................................................................242.16 0xF00CE0015 Failed To Monitor An Engine............................................................................................................252.17 0xF00CE0018 Controller Failed To Monitor An Engine Rear Panel........................................................................262.18 0xF00CE001D Expansion Ports Are Working At Inconsistent Rates.......................................................................272.19 0xF00CE002A Disk Enclosure Is Working In Single Link State..............................................................................272.20 0xF0CF0006 Controller Is Removed.........................................................................................................................282.21 0xF00CF0014 Failed To Monitor The Controller......................................................................................................292.22 0xF0CF0003 Controller Is Faulty...............................................................................................................................302.23 0xF0CF0004 Incorrect Controller Memory Capacity................................................................................................302.24 0xF0CF0005 Abnormal Communication Between Controllers.................................................................................312.25 0x100F0CF0032 Controller Power Failure................................................................................................................322.26 0xF00CF0017 Incorrect Connection Between A Controller Port And A Switch Port...............................................332.27 0x200F00CF0022 Failed To Start A Controller.........................................................................................................342.28 0x100F00CF0027 Controller Restarts........................................................................................................................342.29 0x100F00CF002A Controller Cache Failed To Flush Data.......................................................................................35

OceanStor 5300 V3&5500 V3&5600 V3&5800 V3&6800V3 Storage SystemEvent Reference Contents

Issue 04 (2015-06-10) Huawei Proprietary and ConfidentialCopyright © Huawei Technologies Co., Ltd.

iv

2.30 0x100F00CF0034 A Controller Is Isolated................................................................................................................362.31 0xF00CF0035 The System Is Abnormal....................................................................................................................372.32 0xF00CF0036 Controller Services Are Abnormal.....................................................................................................372.33 0x100F00CF0037 Controller Is About To Restart.....................................................................................................382.34 0xF0050001 Expansion Module Is Removed............................................................................................................392.35 0xF0050002 Expansion Module Is Not Inserted........................................................................................................392.36 0xF0050003 Expansion Module Is Faulty..................................................................................................................402.37 0xF00D00014 Abnormal Communication Between Expansion Modules.................................................................412.38 0xF00D00016 Expansion Module Is Incorrectly Cabled...........................................................................................422.39 0xF0D10001 Management Module Is Removed........................................................................................................422.40 0xF0D10002 Management Module Is Faulty.............................................................................................................432.41 0xF0D10005 Interface Module Is Removed..............................................................................................................442.42 0xF0D10006 Interface Module Is Faulty...................................................................................................................442.43 0xF0D10008 Interface Module Is Unrecognizable....................................................................................................452.44 0xF0D10009 Interface Module Temperature Exceeds The Upper Limit...................................................................462.45 0xF0D1000A Incorrect Removal Of Interface Module..............................................................................................472.46 0xF010A0017 The Communication Between Controller And Management Module Is Disconnected.....................482.47 0xF00D1001E The System Failed To Monitor An Interface Module........................................................................492.48 0xF00A0001 Disk Is Faulty.......................................................................................................................................492.49 0xF00A0002 Unrecognizable Disk............................................................................................................................502.50 0xF00A0003 Disk Is About To Fail...........................................................................................................................512.51 0xF00A0004 Disk Temperature Exceeds The Upper Limit.......................................................................................522.52 0xF00A0008 Coffer Disk Is Faulty............................................................................................................................532.53 0xF00A000A Coffer Disks Not Found......................................................................................................................542.54 0xF000A0015 The System Failed To Monitor A Disk In A Disk Enclosure............................................................552.55 0xF00A000D Slow Disk Response............................................................................................................................562.56 0xF00A000E Incompatible Disk Model.....................................................................................................................572.57 0xF00A000C Disk Is In Single Link State.................................................................................................................582.58 0xF00A0006 Disk Has Too Many Bit Error..............................................................................................................582.59 0xF000A001A Disk Temperature Is Below The Lower Limit..................................................................................592.60 0xF000A004E Coffer Disks Not Found.....................................................................................................................602.61 0xF000A004F The Coffer Disk Is Inserted Into An Incorrect Slot............................................................................612.62 0xF0170001 Power Module Is Not Inserted...............................................................................................................622.63 0xF0170002 Power Module Is Removed...................................................................................................................632.64 0xF0170003 Power Module Is Faulty........................................................................................................................642.65 0xF0170004 Power Module Temperature Exceeds The Upper Limit........................................................................642.66 0xF0170005 Power Module Input Is Abnormal.........................................................................................................652.67 0xF00170014 Power Module Has No Input...............................................................................................................662.68 0xF00170017 The System Failed To Monitor A Power Module...............................................................................682.69 0x100F0170006 Power Module Incompatible...........................................................................................................682.70 0x100F0170008 Multi-Vendor Power Modules In The Same Enclosure..................................................................69

OceanStor 5300 V3&5500 V3&5600 V3&5800 V3&6800V3 Storage SystemEvent Reference Contents

Issue 04 (2015-06-10) Huawei Proprietary and ConfidentialCopyright © Huawei Technologies Co., Ltd.

v

2.71 0xF0D20002 BBU Module Is Faulty.........................................................................................................................702.72 0xF0D20003 BBU Module Reaches Its Expiration Date Or Is Aging.......................................................................712.73 0xF0D20007 BBU Module Is About To Expire........................................................................................................712.74 0xF0D20004 BBU Module Is Removed....................................................................................................................722.75 0xF0D20005 BBU Module Temperature Exceeds The Upper Limit.........................................................................732.76 0xF00D2001B BBU Module Temperature Is Below The Lower Limit....................................................................742.77 0xF00D20014 The System Failed To Monitor A BBU Module................................................................................752.78 0xF0D30001 Fan Module Is Faulty............................................................................................................................762.79 0xF0D30002 Fan Module Is Not Inserted..................................................................................................................762.80 0xF0D30003 Fan Module Is Removed......................................................................................................................772.81 0xF00D30014 The System Failed To Monitor A Fan Module..................................................................................782.82 0xF0060002 Expansion Port Link Down...................................................................................................................792.83 0xF0060003 Expansion Port Is Faulty.......................................................................................................................802.84 0xF0060004 Host Port Link Down............................................................................................................................812.85 0xF0060005 Host Port Is Faulty.................................................................................................................................822.86 0xF0060006 Expansion Port Partially Damaged........................................................................................................822.87 0xF01080014 Expansion Port Has Too Many Bit Errors...........................................................................................832.88 0xF0060010 Expansion Port Isolated.........................................................................................................................842.89 0xF01080015 Host Port Has Too Many Bit Errors....................................................................................................852.90 0xF01080016 PCIE Port Partially Damaged..............................................................................................................862.91 0xF01080018 PCIE Port Is Faulty..............................................................................................................................872.92 0xF01080019 PCIE Port Disconnected......................................................................................................................872.93 0xF0108001A PCIE Port Has Too Many Bit Errors..................................................................................................882.94 0xF0060011 Network Port Is Working In Half-Duplex Mode..................................................................................892.95 0xF0108001D Port Negotiated Rate Is Smaller Than The Allowed Maximum........................................................902.96 0xF01080048 Management Network Port Is Faulty..................................................................................................912.97 0xF01080049 Management Network Port Is Disconnected.......................................................................................912.98 0xF0EA0003 Port Optical Module Is Faulty..............................................................................................................922.99 0xF0EA0004 Port Unavailable Due To Incompatible Optical Module Type............................................................932.100 0xF0EA0005 Optical Module Rate Is Inconsistent With That Of Its Port...............................................................942.101 0xF00EA0016 Optical Module Temperature Is Below The Lower Limit...............................................................942.102 0xF00EA0014 Abnormal Port Link.........................................................................................................................952.103 0xF00EA0015 The System Failed To Monitor An Optical Module........................................................................962.104 0xF00EA0017 Optical Module Temperature Exceeds The Upper Limit.................................................................972.105 0xF00B0001 LUN Is Faulty.....................................................................................................................................982.106 0xF00B0002 LUN Has A Medium Error.................................................................................................................992.107 0x100F000B0016 Switchover Failure Occurs On The Owning Controller Of A LUN...........................................992.108 0xF00B003D Snapshot LUN Is Faulty..................................................................................................................1002.109 0xF000B0050 LUN Has A Medium Error.............................................................................................................1012.110 0xF000B0051 LUN Has A Medium Error.............................................................................................................1012.111 0xF0DB0002 Full LUN Copy Is Faulty.................................................................................................................102

OceanStor 5300 V3&5500 V3&5600 V3&5800 V3&6800V3 Storage SystemEvent Reference Contents

Issue 04 (2015-06-10) Huawei Proprietary and ConfidentialCopyright © Huawei Technologies Co., Ltd.

vi

2.112 0xF0DC0001 Clone Pair Is Abnormally Interrupted.............................................................................................1032.113 0xF0DC0002 Clone Is Unavailable........................................................................................................................1042.114 0xF0DC0003 Clone Pair Is Unavailable................................................................................................................1042.115 0x100F01C0003 Data On The Primary LUN In The Remote Replication Fails To Be Rolled Back....................1052.116 0xF00270038 Remote Replication Is Interrupted..................................................................................................1062.117 0xF00270039 Remote Replication Is Unavailable.................................................................................................1072.118 0xF0027003A Remote Replication Failed To Synchronize Data Automatically..................................................1082.119 0x100F0027008B Failed To Roll Back The Secondary LUN In Remote Replication..........................................1092.120 0xF0DD0001 Remote Replication Consistency Group Is Disconnected...............................................................1092.121 0xF0DD0002 Remote Replication Consistency Group Is Unavailable.................................................................1112.122 0xF01C0005 Remote Replication Consistency Group Failed To Synchronize Data Automatically.....................1112.123 0x100F01B0001 Snapshot Rollback Stopped Unexpectedly.................................................................................1122.124 0xE02050002 Snapshot Unavailable......................................................................................................................1132.125 0x200F001B0046 Succeeded In Canceling Snapshot Rollback.............................................................................1142.126 0x200F001B0047 Failed To Cancel Snapshot Rollback........................................................................................1142.127 0xF0E10001 Replication Link Is Down.................................................................................................................1152.128 0xF00E00014 No Backup Links Available............................................................................................................1162.129 0xF0C90004 CPU Usage Is Too High...................................................................................................................1172.130 0xF0C90005 Memory Usage Is Too High.............................................................................................................1182.131 0xF00CF002F Inconsistent Memory Capacities Between Controllers..................................................................1182.132 0xF010C0014 Number Of Initiators Connected To A Port Exceeds The System Limit.......................................1192.133 0x100F010C0015 iSCSI Initiator Login Failed.....................................................................................................1202.134 0x100F010C0030 Number Of Initiators Connected To A Port Exceeds The System Limit.................................1212.135 0x100F010C0031 Initiator IP Address Is Changed................................................................................................1212.136 0xF010D0027 BBU Firmware Is Incompatible With Storage Array Software.....................................................1222.137 0xF010D0028 Interface Module Firmware Is Incompatible With Storage Array Software..................................1232.138 0xF010D0029 Expansion Module Firmware Is Incompatible With Storage Array Software...............................1242.139 0x200F010D0018 Failed To Delete A Hot Patch..................................................................................................1242.140 0x200F010D001B Failed To Start An Upgrade.....................................................................................................1252.141 0x200F010D001E Failed To Start The Upgrade Of Disk Firmware.....................................................................1262.142 0x200F010D0021 Failed To Start The Upgrade Of Disk Converter Firmware.....................................................1262.143 0x200F010D0024 Failed To Start Rollback...........................................................................................................1272.144 0x100F010D0026 Rollback Failed.........................................................................................................................1282.145 0x100F010D0027 Upgrade Failed.........................................................................................................................1282.146 0xF00150019 Host Is Not Redundantly Connected To Storage Arrays................................................................1292.147 0xF0015001A Link Between A Host And Storage Array Is Down.......................................................................1302.148 0xF0015001B Link Between A Host And Storage Array Is Unstable...................................................................1312.149 0x100F0015001C Ultrapath Is Not Installed Or Ultrapath Version Outdated.......................................................1322.150 0xF0015001D Ultrapath Incompatible With Storage Array Software...................................................................1332.151 0x100F00150036 Data Sent To A Storage Array Port By The Host Failed To Be Verified.................................1342.152 0xF00310004 The Space That Stores Event Logs Is To Be Used Up....................................................................135

OceanStor 5300 V3&5500 V3&5600 V3&5800 V3&6800V3 Storage SystemEvent Reference Contents

Issue 04 (2015-06-10) Huawei Proprietary and ConfidentialCopyright © Huawei Technologies Co., Ltd.

vii

2.153 0xD80001 Storage Pool Remaining Capacity Is Insufficient.................................................................................1352.154 0xD80002 Storage Pool Capacity Is About To Be Used Up..................................................................................1362.155 0x10A0001 Disk Domain Is Degraded..................................................................................................................1372.156 0x10A0002 Disk Domain Is Faulty........................................................................................................................1382.157 0x10A0003 Disk Domain Is Offline......................................................................................................................1392.158 0x10A0005 Hot Spare Capacity Of The Disk Domain Is Insufficient...................................................................1392.159 0x10A0006 Inconsistent Disk Domain Disk Types...............................................................................................1402.160 0x10A0007 Number Of Disks In A Disk Domain Does Not Meet Hot Spare Requirements...............................1412.161 0x10A0008 A Disk Is Removed From A Disk Domain.........................................................................................1422.162 0x1000010A000B The Disk Domain Reconstruction Failed.................................................................................1422.163 0x1000010A000E Precopy Failed..........................................................................................................................1432.164 0x1000010A0011 Data Balancing Failed...............................................................................................................1442.165 0x10A001C Disk Domain Member Disk Is Inserted Into An Incorrect Slot.........................................................1452.166 0x10C000B Controller Write Cache Is Disabled...................................................................................................1452.167 0x10C000C Write Cache For A Cache Partition Is Disabled................................................................................1462.168 0xFD0008 LUN Migration Is Faulty......................................................................................................................1472.169 0xF00CE002B From An Expansion Port, Disk Enclosures And High-Density Disk Enclosures Are Mix-Connected..........................................................................................................................................................................................1482.170 0xF000B0063 External LUN Has Links To Only One Controller.........................................................................1492.171 0xF000B0064 External LUN Offline.....................................................................................................................1502.172 0xF000B0065 External LUN Faulty......................................................................................................................1512.173 0xF000B0066 External LUN Downsized...............................................................................................................1522.174 0xF000B0052 Incompatible Heterogeneous Array Connected To The System....................................................1522.175 0xF000B005D FC Link Of Heterogeneous Array Disconnected...........................................................................1532.176 0xF000B0060 iSCSI Link Of Heterogeneous Array Disconnected.......................................................................1542.177 0xF000B0061 FC Link Of Heterogeneous Array Faulty.......................................................................................1552.178 0xF000B0062 iSCSI Link Of Heterogeneous Array Faulty..................................................................................1562.179 0x200F000A005B The Hard Disk Is Isolated........................................................................................................1572.180 0xF00280045 File System Is Faulty.......................................................................................................................1582.181 0xF00280046 File System Has A Medium Error...................................................................................................1582.182 0xF00280047 Remaining Capacity In A File System Is Insufficient.....................................................................1592.183 0xF00280048 Used Resource Of A File System Quota Exceeds The Soft Quota.................................................1602.184 0xF00280049 File System Has A Checksum Error................................................................................................1602.185 0x100F0028004A File System Has A Memory Allocation Error..........................................................................1612.186 0x10A0021 Failed To Add The New Disk To The Disk Domain..........................................................................1622.187 0x10A0020 A New Disk Fails to Be Added To The Disk Domain.......................................................................1632.188 0xF4045000E Adding To An AD Domain Fails....................................................................................................1642.189 0x200F4045000F No Domain Controller Is Available..........................................................................................1652.190 0xF40020001 The Ndmp Service Process Is Abnormal........................................................................................1662.191 0xF40020002 A Service Port Conflicts..................................................................................................................1672.192 0xF0D30004 Fan Module Is Faulty........................................................................................................................1672.193 0xF00D1001F Management Module Is Faulty......................................................................................................168

OceanStor 5300 V3&5500 V3&5600 V3&5800 V3&6800V3 Storage SystemEvent Reference Contents

Issue 04 (2015-06-10) Huawei Proprietary and ConfidentialCopyright © Huawei Technologies Co., Ltd.

viii

2.194 0xF00D10020 Interface Module Is Faulty.............................................................................................................1692.195 0xF00170018 The Power Module Is Incompatible With The Storage System......................................................1702.196 0xF00EA0018 The System Failed To Monitor An Optical/Electrical Module......................................................1702.197 0x200F0D1000D The System Failed To Power Off An Interface Module............................................................1712.198 0x200F0D10010 The System Failed To Power On An Interface Module.............................................................1722.199 0x200F00D10017 The System Failed to Power Off An Interface Module............................................................1732.200 0x200F00D1001C The System Failed to Power On An Interface Module............................................................1732.201 0x200F00C90088 Succeeded In Deleting All Configurations Of System.............................................................1742.202 0x200F00C90089 Failed To Delete All Configurations Of System......................................................................1752.203 0xF00CA0008 The Super Administrator Needs To Review User Account Information.......................................1762.204 0xF40450029 No LDAP/NIS Server Is Available.................................................................................................1762.205 0xF02470010 Mirror Copy Is Abnormally Interrupted..........................................................................................1772.206 0xF02470011 Mirror Copy Is Unavailable............................................................................................................1782.207 0xF032C0001 The SSH Service Is Abnormal........................................................................................................1792.208 0xF032C0002 The FTP Service Is Abnormal........................................................................................................1802.209 0xF032C0003 NTP Time Synchronization Is Abnormal.......................................................................................1802.210 0xF032C0004 The Network Protocol Stack Of A Controller Is Abnormal...........................................................1812.211 0xF032C0005 The Process CPU Usage Is Too High.............................................................................................1822.212 0xF032C0006 The Process Memory Usage Is Too High.......................................................................................1822.213 0xF032C0007 A Directory Is Oversized................................................................................................................1832.214 0xF032C0008 Excessive Files Exist In A Directory..............................................................................................1842.215 0x200F00CF003A The Heartbeat Connection Between A Controller And A Management Module Is Interrupted..........................................................................................................................................................................................1842.216 0xF00D10011 The PCIe Channel Between An Interface Module And A Controller Is Abnormal.......................1852.217 0xF000A005F Slow Disk Response.......................................................................................................................1862.218 0x200F010D0029 Failed To Start Dispatch Upgrade Package..............................................................................1872.219 0x100F010D0031 Dispatch Upgrade Package Failed............................................................................................1882.220 0xF00D10012 Interface Module Is Inserted Into An Incorrect Slot.......................................................................1892.221 0xF00280074 File System Metadata Is Damaged..................................................................................................1892.222 0xF00280075 Write Protection Is Enabled For The File System...........................................................................1902.223 0xF00280076 Files Or Directories Are Damaged..................................................................................................1912.224 0xF000B0102 External LUN Is Changed To Command Device...........................................................................1912.225 0xF00D10013 Some Statuses Of A Management Module Cannot Be Monitored.................................................1922.226 0xF00CF004A Some Statuses Of A Controller Cannot Be Monitored..................................................................1932.227 0xF01050017 Switch Temperature Is Below The Lower Limit.............................................................................1942.228 0xF0105001E Switch Management Network Port Is Faulty..................................................................................1952.229 0xF0105001F Switch Port Is Faulty.......................................................................................................................1952.230 0xF01050022 Switch Port Optical Module Is Faulty.............................................................................................1962.231 0xF01050024 Switch Port Negotiated Rate Is Smaller Than The Allowed Maximum.........................................1972.232 0xF01050025 Switch Optical Module Temperature Is Below The Lower Limit..................................................1982.233 0xF01050026 Link To A Switch Port Is Abnormal...............................................................................................1992.234 0xF01050027 Failed To Monitor A Switch Optical Module.................................................................................199

OceanStor 5300 V3&5500 V3&5600 V3&5800 V3&6800V3 Storage SystemEvent Reference Contents

Issue 04 (2015-06-10) Huawei Proprietary and ConfidentialCopyright © Huawei Technologies Co., Ltd.

ix

2.235 0xF01050029 Switch Optical Module Temperature Is Too High..........................................................................2002.236 0xDA0005 A Member Disk Of A SmartCache Pool Gets A Fault........................................................................2012.237 0x200F406E0013 An Ndmp Backup Task Fails....................................................................................................2022.238 0xF406E0014 An Ndmp Recovery Task Fails.......................................................................................................2032.239 0xF406E0015 Ndmp Authentication Fails, And The Ip Address Of Backup Software Is Locked........................2042.240 0xF00270130 A Remote Replication Fails To Synchronize Data Automatically..................................................2052.241 0xF00270112 A Remote Replication Is Unavailable.............................................................................................2062.242 0xF00270113 A Remote Replication Is Abnormally Interrupted..........................................................................2062.243 0xF00CF0056 Only One Cluster Link Is Available...............................................................................................2082.244 0xF000A0084 The Disk Is Rejected By The System.............................................................................................2082.245 0x1FFFFFFFFFFFFFFC Testing The Alarm Function..........................................................................................2092.246 0xF00C9013D IP Address Conflict........................................................................................................................2102.247 0xF010D0032 The Management Module Firmware Is Incompatible With Storage Array Software....................2102.248 0xF01060060 Cache Partition Failed To Process Received I/O............................................................................2112.249 0x100F01060063 Controller Is Overloaded...........................................................................................................2122.250 0xF00D00017 Failed To Synchronize The Firmware Version Of An Expansion Module....................................2132.251 0xF00CF0059 Heartbeat Connection Between A Controller And A Management Module Is Interrupted...........2142.252 0xF00270137 Remote Replication Is Automatically Split.....................................................................................2142.253 0xF0DD0004 Remote Replication Consistency Group Is Automatically Split.....................................................2152.254 0xF40020005 Number Of NAS Client Connections Of A Controller Reaches The Upper Limit.........................2162.255 0xF00D80119 Storage Pool Remaining Capacity Is Insufficient..........................................................................2172.256 0xF00D80120 Storage Pool Capacity Is About To Be Used Up...........................................................................2182.257 0xF01060043 Failed To Reach The Control Objective Of SmartQoS...................................................................2182.258 0xF40020006 Number Of File Information Items To Be Backed Up Reaches The Upper Limit.........................2192.259 0xF40440017 Controller Is Disconnected From An LDAP/NIS Server................................................................2202.260 0x100F03300072 Failed To Restore A Virtual Machine.......................................................................................2212.261 0x100F03300073 Failed To Shut Down A Virtual Machine.................................................................................2222.262 0x100F03300074 Incomplete Virtual Machine Creation.......................................................................................2222.263 0xF00280112 Number Of Files In A File System Is About To Exceed The Upper Limit....................................2232.264 0xF00280113 Number Of Files In A Directory Of A File System Is About To Exceed The Upper Limit...........2242.265 0xF00CF005C Number Of Opened Files On A Controller Is About To Exceed The Upper Limit.......................225

A How to Obtain Help.................................................................................................................226A.1 Preparations For Contacting Huawei.........................................................................................................................227A.1.1 Collecting Troubleshooting Information................................................................................................................227A.1.2 Making Debugging Preparations............................................................................................................................227A.2 How to Use the Document.........................................................................................................................................227A.3 How to Obtain Help from Website............................................................................................................................227A.4 Ways to Contact Huawei...........................................................................................................................................228

B Glossary......................................................................................................................................229

OceanStor 5300 V3&5500 V3&5600 V3&5800 V3&6800V3 Storage SystemEvent Reference Contents

Issue 04 (2015-06-10) Huawei Proprietary and ConfidentialCopyright © Huawei Technologies Co., Ltd.

x

C Acronyms and Abbreviations................................................................................................241

OceanStor 5300 V3&5500 V3&5600 V3&5800 V3&6800V3 Storage SystemEvent Reference Contents

Issue 04 (2015-06-10) Huawei Proprietary and ConfidentialCopyright © Huawei Technologies Co., Ltd.

xi

1 Overview

This chapter describes the event levels and event signal flows.

Event LevelAn event level indicates the severity of the event to the system services. The event level isdisplayed on the DeviceManager interface and can be classified into the following levels:

l CriticalThis level indicates that a fault has caused service interruption or device failure. Recoverymeasures should be taken immediately.

l MajorThis level indicates that a fault has certain impact on the device or system performance.Measures should be taken immediately to prevent more serious faults. All hardware faultsare of the level.

l WarningThis level indicates that a fault has no impact on the device. The system detects a potentialor an imminent fault that is about to affect the services.

Event Signal FlowIf the storage system is faulty, the module in which the fault occurs reports the fault to the servicecontrol module and alarm module. The service control module and alarm module analyze thefault information. Then the service control module reports the fault information to the underlyingmodule for further handling. The alarm module reports the fault information to the device alarmindicator to generate visual alarm, and to the DeviceManager through the maintenance interfaceto display the alarm status and cause.

Figure 1-1 shows the event signal flow figure of the storage system.

OceanStor 5300 V3&5500 V3&5600 V3&5800 V3&6800V3 Storage SystemEvent Reference 1 Overview

Issue 04 (2015-06-10) Huawei Proprietary and ConfidentialCopyright © Huawei Technologies Co., Ltd.

1

Figure 1-1 Event signal flow figure

Module fault

Alarm moduleAlarm indicator informs

Software interface displays

Service control module

Underlying module process

② ②

(1) Indicates that a module is faulty, and the fault information is reported to the service controlmodule and alarm module.

(2) Indicates that the service control module and alarm module analyze the fault information,and then respectively report it. Herein:l The service control module reports the fault information to the underlying module for

further handling.l The alarm module reports the fault information to the device alarm indicator to generate a

visual alarm, and to the DeviceManager through the maintenance interface to display thealarm status and cause.

OceanStor 5300 V3&5500 V3&5600 V3&5800 V3&6800V3 Storage SystemEvent Reference 1 Overview

Issue 04 (2015-06-10) Huawei Proprietary and ConfidentialCopyright © Huawei Technologies Co., Ltd.

2

2 Troubleshooting Events

About This Chapter

This chapter describes the information about troubleshooting events, including eventdescription, event attribute, impact on system, possible causes, and handling procedure.

2.1 0xF0C90001 License Is About To Expire

2.2 0xF0C90002 License Has Expired

2.3 0xF0C90003 Invalid License

2.4 0xF00C90015 Controller Write Cache Is Disabled

2.5 0xF0C90006 The System Has Entered Safe Mode

2.6 0x100F0C9000C Controller Failed To Be Powered On Again

2.7 0x100F0C90065 System Engine Is Working In Single Controller State

2.8 0xF0CE0001 Failed To Monitor A Disk Enclosure

2.9 0xF0CE0002 Disk Enclosure Quantity Exceeds The System Limit

2.10 0xF0CE0004 Failed To Identify An Engine Or Disk Enclosure

2.11 0xF0CE0005 Disk Enclosure Temperature Exceeds The Upper Limit

2.12 0xF0CE000A Disk Enclosure Temperature Is Far Beyond The Upper Limit

2.13 0xF0CE0007 Engine Or Disk Enclosure Temperature Is Below The Lower Limit

2.14 0xF0CE0008 Engine Temperature Exceeds The Upper Limit

2.15 0xF0CE0009 Engine Temperature Is Far Beyond The Upper Limit

2.16 0xF00CE0015 Failed To Monitor An Engine

2.17 0xF00CE0018 Controller Failed To Monitor An Engine Rear Panel

2.18 0xF00CE001D Expansion Ports Are Working At Inconsistent Rates

2.19 0xF00CE002A Disk Enclosure Is Working In Single Link State

OceanStor 5300 V3&5500 V3&5600 V3&5800 V3&6800V3 Storage SystemEvent Reference 2 Troubleshooting Events

Issue 04 (2015-06-10) Huawei Proprietary and ConfidentialCopyright © Huawei Technologies Co., Ltd.

3

2.20 0xF0CF0006 Controller Is Removed

2.21 0xF00CF0014 Failed To Monitor The Controller

2.22 0xF0CF0003 Controller Is Faulty

2.23 0xF0CF0004 Incorrect Controller Memory Capacity

2.24 0xF0CF0005 Abnormal Communication Between Controllers

2.25 0x100F0CF0032 Controller Power Failure

2.26 0xF00CF0017 Incorrect Connection Between A Controller Port And A Switch Port

2.27 0x200F00CF0022 Failed To Start A Controller

2.28 0x100F00CF0027 Controller Restarts

2.29 0x100F00CF002A Controller Cache Failed To Flush Data

2.30 0x100F00CF0034 A Controller Is Isolated

2.31 0xF00CF0035 The System Is Abnormal

2.32 0xF00CF0036 Controller Services Are Abnormal

2.33 0x100F00CF0037 Controller Is About To Restart

2.34 0xF0050001 Expansion Module Is Removed

2.35 0xF0050002 Expansion Module Is Not Inserted

2.36 0xF0050003 Expansion Module Is Faulty

2.37 0xF00D00014 Abnormal Communication Between Expansion Modules

2.38 0xF00D00016 Expansion Module Is Incorrectly Cabled

2.39 0xF0D10001 Management Module Is Removed

2.40 0xF0D10002 Management Module Is Faulty

2.41 0xF0D10005 Interface Module Is Removed

2.42 0xF0D10006 Interface Module Is Faulty

2.43 0xF0D10008 Interface Module Is Unrecognizable

2.44 0xF0D10009 Interface Module Temperature Exceeds The Upper Limit

2.45 0xF0D1000A Incorrect Removal Of Interface Module

2.46 0xF010A0017 The Communication Between Controller And Management Module IsDisconnected

2.47 0xF00D1001E The System Failed To Monitor An Interface Module

2.48 0xF00A0001 Disk Is Faulty

2.49 0xF00A0002 Unrecognizable Disk

2.50 0xF00A0003 Disk Is About To Fail

OceanStor 5300 V3&5500 V3&5600 V3&5800 V3&6800V3 Storage SystemEvent Reference 2 Troubleshooting Events

Issue 04 (2015-06-10) Huawei Proprietary and ConfidentialCopyright © Huawei Technologies Co., Ltd.

4

2.51 0xF00A0004 Disk Temperature Exceeds The Upper Limit

2.52 0xF00A0008 Coffer Disk Is Faulty

2.53 0xF00A000A Coffer Disks Not Found

2.54 0xF000A0015 The System Failed To Monitor A Disk In A Disk Enclosure

2.55 0xF00A000D Slow Disk Response

2.56 0xF00A000E Incompatible Disk Model

2.57 0xF00A000C Disk Is In Single Link State

2.58 0xF00A0006 Disk Has Too Many Bit Error

2.59 0xF000A001A Disk Temperature Is Below The Lower Limit

2.60 0xF000A004E Coffer Disks Not Found

2.61 0xF000A004F The Coffer Disk Is Inserted Into An Incorrect Slot

2.62 0xF0170001 Power Module Is Not Inserted

2.63 0xF0170002 Power Module Is Removed

2.64 0xF0170003 Power Module Is Faulty

2.65 0xF0170004 Power Module Temperature Exceeds The Upper Limit

2.66 0xF0170005 Power Module Input Is Abnormal

2.67 0xF00170014 Power Module Has No Input

2.68 0xF00170017 The System Failed To Monitor A Power Module

2.69 0x100F0170006 Power Module Incompatible

2.70 0x100F0170008 Multi-Vendor Power Modules In The Same Enclosure

2.71 0xF0D20002 BBU Module Is Faulty

2.72 0xF0D20003 BBU Module Reaches Its Expiration Date Or Is Aging

2.73 0xF0D20007 BBU Module Is About To Expire

2.74 0xF0D20004 BBU Module Is Removed

2.75 0xF0D20005 BBU Module Temperature Exceeds The Upper Limit

2.76 0xF00D2001B BBU Module Temperature Is Below The Lower Limit

2.77 0xF00D20014 The System Failed To Monitor A BBU Module

2.78 0xF0D30001 Fan Module Is Faulty

2.79 0xF0D30002 Fan Module Is Not Inserted

2.80 0xF0D30003 Fan Module Is Removed

2.81 0xF00D30014 The System Failed To Monitor A Fan Module

2.82 0xF0060002 Expansion Port Link Down

OceanStor 5300 V3&5500 V3&5600 V3&5800 V3&6800V3 Storage SystemEvent Reference 2 Troubleshooting Events

Issue 04 (2015-06-10) Huawei Proprietary and ConfidentialCopyright © Huawei Technologies Co., Ltd.

5

2.83 0xF0060003 Expansion Port Is Faulty

2.84 0xF0060004 Host Port Link Down

2.85 0xF0060005 Host Port Is Faulty

2.86 0xF0060006 Expansion Port Partially Damaged

2.87 0xF01080014 Expansion Port Has Too Many Bit Errors

2.88 0xF0060010 Expansion Port Isolated

2.89 0xF01080015 Host Port Has Too Many Bit Errors

2.90 0xF01080016 PCIE Port Partially Damaged

2.91 0xF01080018 PCIE Port Is Faulty

2.92 0xF01080019 PCIE Port Disconnected

2.93 0xF0108001A PCIE Port Has Too Many Bit Errors

2.94 0xF0060011 Network Port Is Working In Half-Duplex Mode

2.95 0xF0108001D Port Negotiated Rate Is Smaller Than The Allowed Maximum

2.96 0xF01080048 Management Network Port Is Faulty

2.97 0xF01080049 Management Network Port Is Disconnected

2.98 0xF0EA0003 Port Optical Module Is Faulty

2.99 0xF0EA0004 Port Unavailable Due To Incompatible Optical Module Type

2.100 0xF0EA0005 Optical Module Rate Is Inconsistent With That Of Its Port

2.101 0xF00EA0016 Optical Module Temperature Is Below The Lower Limit

2.102 0xF00EA0014 Abnormal Port Link

2.103 0xF00EA0015 The System Failed To Monitor An Optical Module

2.104 0xF00EA0017 Optical Module Temperature Exceeds The Upper Limit

2.105 0xF00B0001 LUN Is Faulty

2.106 0xF00B0002 LUN Has A Medium Error

2.107 0x100F000B0016 Switchover Failure Occurs On The Owning Controller Of A LUN

2.108 0xF00B003D Snapshot LUN Is Faulty

2.109 0xF000B0050 LUN Has A Medium Error

2.110 0xF000B0051 LUN Has A Medium Error

2.111 0xF0DB0002 Full LUN Copy Is Faulty

2.112 0xF0DC0001 Clone Pair Is Abnormally Interrupted

2.113 0xF0DC0002 Clone Is Unavailable

2.114 0xF0DC0003 Clone Pair Is Unavailable

OceanStor 5300 V3&5500 V3&5600 V3&5800 V3&6800V3 Storage SystemEvent Reference 2 Troubleshooting Events

Issue 04 (2015-06-10) Huawei Proprietary and ConfidentialCopyright © Huawei Technologies Co., Ltd.

6

2.115 0x100F01C0003 Data On The Primary LUN In The Remote Replication Fails To BeRolled Back

2.116 0xF00270038 Remote Replication Is Interrupted

2.117 0xF00270039 Remote Replication Is Unavailable

2.118 0xF0027003A Remote Replication Failed To Synchronize Data Automatically

2.119 0x100F0027008B Failed To Roll Back The Secondary LUN In Remote Replication

2.120 0xF0DD0001 Remote Replication Consistency Group Is Disconnected

2.121 0xF0DD0002 Remote Replication Consistency Group Is Unavailable

2.122 0xF01C0005 Remote Replication Consistency Group Failed To Synchronize DataAutomatically

2.123 0x100F01B0001 Snapshot Rollback Stopped Unexpectedly

2.124 0xE02050002 Snapshot Unavailable

2.125 0x200F001B0046 Succeeded In Canceling Snapshot Rollback

2.126 0x200F001B0047 Failed To Cancel Snapshot Rollback

2.127 0xF0E10001 Replication Link Is Down

2.128 0xF00E00014 No Backup Links Available

2.129 0xF0C90004 CPU Usage Is Too High

2.130 0xF0C90005 Memory Usage Is Too High

2.131 0xF00CF002F Inconsistent Memory Capacities Between Controllers

2.132 0xF010C0014 Number Of Initiators Connected To A Port Exceeds The System Limit

2.133 0x100F010C0015 iSCSI Initiator Login Failed

2.134 0x100F010C0030 Number Of Initiators Connected To A Port Exceeds The System Limit

2.135 0x100F010C0031 Initiator IP Address Is Changed

2.136 0xF010D0027 BBU Firmware Is Incompatible With Storage Array Software

2.137 0xF010D0028 Interface Module Firmware Is Incompatible With Storage Array Software

2.138 0xF010D0029 Expansion Module Firmware Is Incompatible With Storage Array Software

2.139 0x200F010D0018 Failed To Delete A Hot Patch

2.140 0x200F010D001B Failed To Start An Upgrade

2.141 0x200F010D001E Failed To Start The Upgrade Of Disk Firmware

2.142 0x200F010D0021 Failed To Start The Upgrade Of Disk Converter Firmware

2.143 0x200F010D0024 Failed To Start Rollback

2.144 0x100F010D0026 Rollback Failed

2.145 0x100F010D0027 Upgrade Failed

OceanStor 5300 V3&5500 V3&5600 V3&5800 V3&6800V3 Storage SystemEvent Reference 2 Troubleshooting Events

Issue 04 (2015-06-10) Huawei Proprietary and ConfidentialCopyright © Huawei Technologies Co., Ltd.

7

2.146 0xF00150019 Host Is Not Redundantly Connected To Storage Arrays

2.147 0xF0015001A Link Between A Host And Storage Array Is Down

2.148 0xF0015001B Link Between A Host And Storage Array Is Unstable

2.149 0x100F0015001C Ultrapath Is Not Installed Or Ultrapath Version Outdated

2.150 0xF0015001D Ultrapath Incompatible With Storage Array Software

2.151 0x100F00150036 Data Sent To A Storage Array Port By The Host Failed To Be Verified

2.152 0xF00310004 The Space That Stores Event Logs Is To Be Used Up

2.153 0xD80001 Storage Pool Remaining Capacity Is Insufficient

2.154 0xD80002 Storage Pool Capacity Is About To Be Used Up

2.155 0x10A0001 Disk Domain Is Degraded

2.156 0x10A0002 Disk Domain Is Faulty

2.157 0x10A0003 Disk Domain Is Offline

2.158 0x10A0005 Hot Spare Capacity Of The Disk Domain Is Insufficient

2.159 0x10A0006 Inconsistent Disk Domain Disk Types

2.160 0x10A0007 Number Of Disks In A Disk Domain Does Not Meet Hot Spare Requirements

2.161 0x10A0008 A Disk Is Removed From A Disk Domain

2.162 0x1000010A000B The Disk Domain Reconstruction Failed

2.163 0x1000010A000E Precopy Failed

2.164 0x1000010A0011 Data Balancing Failed

2.165 0x10A001C Disk Domain Member Disk Is Inserted Into An Incorrect Slot

2.166 0x10C000B Controller Write Cache Is Disabled

2.167 0x10C000C Write Cache For A Cache Partition Is Disabled

2.168 0xFD0008 LUN Migration Is Faulty

2.169 0xF00CE002B From An Expansion Port, Disk Enclosures And High-Density DiskEnclosures Are Mix-Connected

2.170 0xF000B0063 External LUN Has Links To Only One Controller

2.171 0xF000B0064 External LUN Offline

2.172 0xF000B0065 External LUN Faulty

2.173 0xF000B0066 External LUN Downsized

2.174 0xF000B0052 Incompatible Heterogeneous Array Connected To The System

2.175 0xF000B005D FC Link Of Heterogeneous Array Disconnected

2.176 0xF000B0060 iSCSI Link Of Heterogeneous Array Disconnected

2.177 0xF000B0061 FC Link Of Heterogeneous Array Faulty

OceanStor 5300 V3&5500 V3&5600 V3&5800 V3&6800V3 Storage SystemEvent Reference 2 Troubleshooting Events

Issue 04 (2015-06-10) Huawei Proprietary and ConfidentialCopyright © Huawei Technologies Co., Ltd.

8

2.178 0xF000B0062 iSCSI Link Of Heterogeneous Array Faulty

2.179 0x200F000A005B The Hard Disk Is Isolated

2.180 0xF00280045 File System Is Faulty

2.181 0xF00280046 File System Has A Medium Error

2.182 0xF00280047 Remaining Capacity In A File System Is Insufficient

2.183 0xF00280048 Used Resource Of A File System Quota Exceeds The Soft Quota

2.184 0xF00280049 File System Has A Checksum Error

2.185 0x100F0028004A File System Has A Memory Allocation Error

2.186 0x10A0021 Failed To Add The New Disk To The Disk Domain

2.187 0x10A0020 A New Disk Fails to Be Added To The Disk Domain

2.188 0xF4045000E Adding To An AD Domain Fails

2.189 0x200F4045000F No Domain Controller Is Available

2.190 0xF40020001 The Ndmp Service Process Is Abnormal

2.191 0xF40020002 A Service Port Conflicts

2.192 0xF0D30004 Fan Module Is Faulty

2.193 0xF00D1001F Management Module Is Faulty

2.194 0xF00D10020 Interface Module Is Faulty

2.195 0xF00170018 The Power Module Is Incompatible With The Storage System

2.196 0xF00EA0018 The System Failed To Monitor An Optical/Electrical Module

2.197 0x200F0D1000D The System Failed To Power Off An Interface Module

2.198 0x200F0D10010 The System Failed To Power On An Interface Module

2.199 0x200F00D10017 The System Failed to Power Off An Interface Module

2.200 0x200F00D1001C The System Failed to Power On An Interface Module

2.201 0x200F00C90088 Succeeded In Deleting All Configurations Of System

2.202 0x200F00C90089 Failed To Delete All Configurations Of System

2.203 0xF00CA0008 The Super Administrator Needs To Review User Account Information

2.204 0xF40450029 No LDAP/NIS Server Is Available

2.205 0xF02470010 Mirror Copy Is Abnormally Interrupted

2.206 0xF02470011 Mirror Copy Is Unavailable

2.207 0xF032C0001 The SSH Service Is Abnormal

2.208 0xF032C0002 The FTP Service Is Abnormal

2.209 0xF032C0003 NTP Time Synchronization Is Abnormal

OceanStor 5300 V3&5500 V3&5600 V3&5800 V3&6800V3 Storage SystemEvent Reference 2 Troubleshooting Events

Issue 04 (2015-06-10) Huawei Proprietary and ConfidentialCopyright © Huawei Technologies Co., Ltd.

9

2.210 0xF032C0004 The Network Protocol Stack Of A Controller Is Abnormal

2.211 0xF032C0005 The Process CPU Usage Is Too High

2.212 0xF032C0006 The Process Memory Usage Is Too High

2.213 0xF032C0007 A Directory Is Oversized

2.214 0xF032C0008 Excessive Files Exist In A Directory

2.215 0x200F00CF003A The Heartbeat Connection Between A Controller And A ManagementModule Is Interrupted

2.216 0xF00D10011 The PCIe Channel Between An Interface Module And A Controller IsAbnormal

2.217 0xF000A005F Slow Disk Response

2.218 0x200F010D0029 Failed To Start Dispatch Upgrade Package

2.219 0x100F010D0031 Dispatch Upgrade Package Failed

2.220 0xF00D10012 Interface Module Is Inserted Into An Incorrect Slot

2.221 0xF00280074 File System Metadata Is Damaged

2.222 0xF00280075 Write Protection Is Enabled For The File System

2.223 0xF00280076 Files Or Directories Are Damaged.

2.224 0xF000B0102 External LUN Is Changed To Command Device

2.225 0xF00D10013 Some Statuses Of A Management Module Cannot Be Monitored

2.226 0xF00CF004A Some Statuses Of A Controller Cannot Be Monitored

2.227 0xF01050017 Switch Temperature Is Below The Lower Limit

2.228 0xF0105001E Switch Management Network Port Is Faulty

2.229 0xF0105001F Switch Port Is Faulty

2.230 0xF01050022 Switch Port Optical Module Is Faulty

2.231 0xF01050024 Switch Port Negotiated Rate Is Smaller Than The Allowed Maximum

2.232 0xF01050025 Switch Optical Module Temperature Is Below The Lower Limit

2.233 0xF01050026 Link To A Switch Port Is Abnormal

2.234 0xF01050027 Failed To Monitor A Switch Optical Module

2.235 0xF01050029 Switch Optical Module Temperature Is Too High

2.236 0xDA0005 A Member Disk Of A SmartCache Pool Gets A Fault

2.237 0x200F406E0013 An Ndmp Backup Task Fails

2.238 0xF406E0014 An Ndmp Recovery Task Fails

2.239 0xF406E0015 Ndmp Authentication Fails, And The Ip Address Of Backup Software IsLocked

OceanStor 5300 V3&5500 V3&5600 V3&5800 V3&6800V3 Storage SystemEvent Reference 2 Troubleshooting Events

Issue 04 (2015-06-10) Huawei Proprietary and ConfidentialCopyright © Huawei Technologies Co., Ltd.

10

2.240 0xF00270130 A Remote Replication Fails To Synchronize Data Automatically

2.241 0xF00270112 A Remote Replication Is Unavailable

2.242 0xF00270113 A Remote Replication Is Abnormally Interrupted

2.243 0xF00CF0056 Only One Cluster Link Is Available

2.244 0xF000A0084 The Disk Is Rejected By The System

2.245 0x1FFFFFFFFFFFFFFC Testing The Alarm Function

2.246 0xF00C9013D IP Address Conflict

2.247 0xF010D0032 The Management Module Firmware Is Incompatible With Storage ArraySoftware

2.248 0xF01060060 Cache Partition Failed To Process Received I/O

2.249 0x100F01060063 Controller Is Overloaded

2.250 0xF00D00017 Failed To Synchronize The Firmware Version Of An Expansion Module

2.251 0xF00CF0059 Heartbeat Connection Between A Controller And A Management ModuleIs Interrupted

2.252 0xF00270137 Remote Replication Is Automatically Split

2.253 0xF0DD0004 Remote Replication Consistency Group Is Automatically Split

2.254 0xF40020005 Number Of NAS Client Connections Of A Controller Reaches The UpperLimit

2.255 0xF00D80119 Storage Pool Remaining Capacity Is Insufficient

2.256 0xF00D80120 Storage Pool Capacity Is About To Be Used Up

2.257 0xF01060043 Failed To Reach The Control Objective Of SmartQoS

2.258 0xF40020006 Number Of File Information Items To Be Backed Up Reaches The UpperLimit

2.259 0xF40440017 Controller Is Disconnected From An LDAP/NIS Server

2.260 0x100F03300072 Failed To Restore A Virtual Machine

2.261 0x100F03300073 Failed To Shut Down A Virtual Machine

2.262 0x100F03300074 Incomplete Virtual Machine Creation

2.263 0xF00280112 Number Of Files In A File System Is About To Exceed The Upper Limit

2.264 0xF00280113 Number Of Files In A Directory Of A File System Is About To Exceed TheUpper Limit

2.265 0xF00CF005C Number Of Opened Files On A Controller Is About To Exceed The UpperLimit

OceanStor 5300 V3&5500 V3&5600 V3&5800 V3&6800V3 Storage SystemEvent Reference 2 Troubleshooting Events

Issue 04 (2015-06-10) Huawei Proprietary and ConfidentialCopyright © Huawei Technologies Co., Ltd.

11

2.1 0xF0C90001 License Is About To Expire

Description

Feature license is about to expire. You need to purchase required license.

Attribute

ID Event Level Automatically Cleared

0xF0C90001 Warning Yes

Impact on the System

A value-added feature is unavailable after its license expires.

Possible Causes

N/A.

Procedure

Purchase and import required license files.

----End

Related Information

None

2.2 0xF0C90002 License Has Expired

Description

Feature license has expired. You need to purchase required license.

Attribute

ID Event Level Automatically Cleared

0xF0C90002 Major Yes

OceanStor 5300 V3&5500 V3&5600 V3&5800 V3&6800V3 Storage SystemEvent Reference 2 Troubleshooting Events

Issue 04 (2015-06-10) Huawei Proprietary and ConfidentialCopyright © Huawei Technologies Co., Ltd.

12

Impact on the System

After the license of a feature expires, the feature is for trial use only and will become invalidtwo months later.

Possible Causes

N/A.

Procedure

Purchase and import required license files.

----End

Related Information

None

2.3 0xF0C90003 Invalid License

Description

Feature license is invalid. You need to purchase required license.

Attribute

ID Event Level Automatically Cleared

0xF0C90003 Critical Yes

Impact on the System

The value-added feature is unavailable after its license becomes invalid.

Possible Causes

N/A.

Procedure

Purchase and import required license files.

----End

OceanStor 5300 V3&5500 V3&5600 V3&5800 V3&6800V3 Storage SystemEvent Reference 2 Troubleshooting Events

Issue 04 (2015-06-10) Huawei Proprietary and ConfidentialCopyright © Huawei Technologies Co., Ltd.

13

Related Information

None

2.4 0xF00C90015 Controller Write Cache Is Disabled

Description

Write cache of a controller is disabled.

Attribute

ID Event Level Automatically Cleared

0xF00C90015 Major Yes

Impact on the System

System write performance may be compromised.

Possible Causes

l Power modules are faulty.

l BBU modules are faulty.

l Fan modules are faulty.

l Controllers are faulty.

l The temperature is too high.

l Disk or disk enclosures are faulty.

Procedure

Step 1 Check whether alarms are generated indicating power module faults.

1. If yes, replace the faulty power modules. If alarm Controller Write Cache Is Disabledpersists=>Step 2.

2. If no=>Step 2.

Step 2 Check whether alarms are generated indicating BBU module faults.

1. If yes, replace the faulty BBU modules. If alarm Controller Write Cache Is Disabledpersists=>Step 3.

2. If no=>Step 3.

Step 3 Check whether alarms are generated indicating fan module faults.

1. If yes, replace the faulty fan modules. If alarm Controller Write Cache Is Disabledpersists=>Step 4.

2. If no=>Step 4.

OceanStor 5300 V3&5500 V3&5600 V3&5800 V3&6800V3 Storage SystemEvent Reference 2 Troubleshooting Events

Issue 04 (2015-06-10) Huawei Proprietary and ConfidentialCopyright © Huawei Technologies Co., Ltd.

14

Step 4 Check whether alarms are generated indicating controller faults.1. If yes, replace the faulty controllers. If alarm Controller Write Cache Is Disabled

persists=>Step 5.2. If no=>Step 5.

Step 5 Check whether the temperature is higher than the system limit.1. If yes, lower the existing air conditioners temperature or add more air conditioners. If alarm

Controller Write Cache Is Disabled persists=>Step 6.2. If no=>Step 6.

Step 6 Check whether alarms are generated indicating disk or disk enclosure faults.1. If yes, replace the faulty disks or disk enclosures. If alarm Controller Write Cache Is

Disabled persists=>Step 7.2. If no=>Step 7.

Step 7 Collect related information and contact technical support engineers.

----End

Related InformationNone

2.5 0xF0C90006 The System Has Entered Safe Mode

DescriptionAn abnormal controller startup causes the system to enter safe mode.

AttributeID Event Level Automatically Cleared

0xF0C90006 Critical Yes

Impact on the SystemThe system cannot provide services.

Possible CausesThe system fails to be powered on.

Procedure

Collect related information and contact technical support engineers.

----End

OceanStor 5300 V3&5500 V3&5600 V3&5800 V3&6800V3 Storage SystemEvent Reference 2 Troubleshooting Events

Issue 04 (2015-06-10) Huawei Proprietary and ConfidentialCopyright © Huawei Technologies Co., Ltd.

15

Related Information

None

2.6 0x100F0C9000C Controller Failed To Be Powered OnAgain

Description

A controller failed to be powered on after being recovered from a fault.

Attribute

ID Event Level Automatically Cleared

0x100F0C9000C Major Yes

Impact on the System

The storage system cannot work correctly.

Possible Causes

N/A.

Procedure

Collect related information and contact technical support engineers.

----End

Related Information

None

2.7 0x100F0C90065 System Engine Is Working In SingleController State

Description

An engine is working in single controller state.

OceanStor 5300 V3&5500 V3&5600 V3&5800 V3&6800V3 Storage SystemEvent Reference 2 Troubleshooting Events

Issue 04 (2015-06-10) Huawei Proprietary and ConfidentialCopyright © Huawei Technologies Co., Ltd.

16

Attribute

ID Event Level Automatically Cleared

0x100F0C90065 Major Yes

Impact on the System

The I/O performance of the storage system may deteriorate.

Possible Causes

N/A.

Procedure

Collect related information and contact technical support engineers.

----End

Related Information

None

2.8 0xF0CE0001 Failed To Monitor A Disk Enclosure

Description

A disk enclosure fails to be monitored.

Attribute

ID Event Level Automatically Cleared

0xF0CE0001 Critical Yes

Impact on the System

The storage system cannot report disk enclosure faults, causing fault rectification to be delayed.

Possible Causes

l The disk enclosure is powered off.l Expansion cables are removed or damaged.l Expansion modules are faulty.

OceanStor 5300 V3&5500 V3&5600 V3&5800 V3&6800V3 Storage SystemEvent Reference 2 Troubleshooting Events

Issue 04 (2015-06-10) Huawei Proprietary and ConfidentialCopyright © Huawei Technologies Co., Ltd.

17

l Expansion modules are removed.

Procedure

Step 1 Check the disk enclosure.1. If any power cable of the disk enclosure is not removed, insert the power cable and power

on the disk enclosure. If the alarm persists=>Step 1.2.2. If any power supply of the disk enclosure is faulty, replace the power supply and power on

the disk enclosure. If the alarm persists=>Step 2.3. If all power supplies of the disk enclosure are normal=>Step 2.

Step 2 Check expansion cables.1. If any expansion cable is removed, reinsert it. If the alarm persists=>Step 2.2.2. Replace the expansion cable. If the alarm persists=>Step 3.

Step 3 Check whether any expansion module is removed.1. If yes, reinsert the expansion module. If the alarm persists=>Step 4.2. If no=>Step 4.

Step 4 Check whether alarms are generated indicating expansion module faults.1. If yes, replace the faulty expansion modules. If the alarm persists=>Step 5.2. If no=>Step 5.

Step 5 Collect related information and contact technical support engineers.

----End

Related InformationNone

2.9 0xF0CE0002 Disk Enclosure Quantity Exceeds TheSystem Limit

DescriptionThe number of disk enclosures exceeds the system limit.

Attribute

ID Event Level Automatically Cleared

0xF0CE0002 Warning Yes

Impact on the SystemNo more disk enclosures can be added to the storage system.

OceanStor 5300 V3&5500 V3&5600 V3&5800 V3&6800V3 Storage SystemEvent Reference 2 Troubleshooting Events

Issue 04 (2015-06-10) Huawei Proprietary and ConfidentialCopyright © Huawei Technologies Co., Ltd.

18

Possible Causes

Disk enclosure quantity exceeds the system limit.

Procedure

Step 1 Check whether disk enclosure IDs are correctly assigned to all disk enclosures connected to thestorage system.

1. If any disk enclosure is not assigned an ID, the number of disk enclosures exceeds thesystem limit. Remove the extra disk enclosure. If the alarm persists=>Step 2.

2. If all disk enclosures are assigned IDs=>Step 2.

Step 2 Check whether any information about a disconnected disk enclosure is found in systemconfiguration information.

1. If yes, delete the information about the disconnected disk enclosure and reinsert expansioncables of the connected disk enclosures. If the alarm persists=>Step 3.

2. If no=>Step 3.

Step 3 Collect related information and contact technical support engineers.

----End

Related Information

None

2.10 0xF0CE0004 Failed To Identify An Engine Or DiskEnclosure

Description

The storage system failed to identify an engine or disk enclosure.

Attribute

ID Event Level Automatically Cleared

0xF0CE0004 Major Yes

Impact on the System

The storage system failed to identify an engine or disk enclosure.

Possible Causes

The enclosure MAC address or serial number is invalid.

OceanStor 5300 V3&5500 V3&5600 V3&5800 V3&6800V3 Storage SystemEvent Reference 2 Troubleshooting Events

Issue 04 (2015-06-10) Huawei Proprietary and ConfidentialCopyright © Huawei Technologies Co., Ltd.

19

Procedure

Collect related information and contact technical support engineers.

----End

Related Information

None

2.11 0xF0CE0005 Disk Enclosure Temperature Exceeds TheUpper Limit

Description

The working temperature of a disk enclosure exceeds the upper limit.

Attribute

ID Event Level Automatically Cleared

0xF0CE0005 Major Yes

Impact on the System

The normal operation of the storage system may be adversely affected.

Possible Causes

l Fan modules are faulty.

l Heat dissipation channels in the disk enclosure are blocked.

l The ambient temperature exceeds the upper limit.

Procedure

Step 1 Check whether alarms are generated indicating fan module faults.

1. If yes, replace the faulty fan modules. If alarm Disk Enclosure Temperature Exceeds theUpper Limit persists=>Step 2.

2. If no=>Step 2.

Step 2 Check whether heat dissipation channels in the disk enclosure are blocked.

1. If yes, clear the heat dissipation channels. If alarm Disk Enclosure Temperature Exceedsthe Upper Limit persists=>Step 3.

2. If no=>Step 3.

OceanStor 5300 V3&5500 V3&5600 V3&5800 V3&6800V3 Storage SystemEvent Reference 2 Troubleshooting Events

Issue 04 (2015-06-10) Huawei Proprietary and ConfidentialCopyright © Huawei Technologies Co., Ltd.

20

Step 3 Check whether the ambient temperature is too high.

1. If yes, lower the existing air conditioners temperature or add more air conditioners. If alarmDisk Enclosure Temperature Exceeds the Upper Limit persists=>Step 4.

2. If no=>Step 4.

Step 4 Collect related information and contact technical support engineers.

----End

Related Information

None

2.12 0xF0CE000A Disk Enclosure Temperature Is FarBeyond The Upper Limit

Description

The temperature of a disk enclosure is far beyond the upper limit.

Attribute

ID Event Level Automatically Cleared

0xF0CE000A Major Yes

Impact on the System

The normal operation of the storage system may be adversely affected.

Possible Causes

l Fan modules are faulty.

l Heat dissipation channels in the disk enclosure are blocked.

l The ambient temperature exceeds the upper limit.

Procedure

Step 1 Check whether alarms are generated indicating fan module faults.

1. If yes, replace the faulty fan modules. If alarm Disk Enclosure Temperature Is Far Beyondthe Upper Limit persists=>Step 2.

2. If no=>Step 2.

Step 2 Check whether heat dissipation channels in the disk enclosure are blocked.

1. If yes, clear the heat dissipation channels. If alarm Disk Enclosure Temperature Is FarBeyond the Upper Limit persists=>Step 3.

OceanStor 5300 V3&5500 V3&5600 V3&5800 V3&6800V3 Storage SystemEvent Reference 2 Troubleshooting Events

Issue 04 (2015-06-10) Huawei Proprietary and ConfidentialCopyright © Huawei Technologies Co., Ltd.

21

2. If no=>Step 3.

Step 3 Check whether the ambient temperature is too high.

1. If yes, lower the existing air conditioners temperature or add more air conditioners. If alarmDisk Enclosure Temperature Is Far Beyond the Upper Limit persists=>Step 4.

2. If no=>Step 4.

Step 4 Collect related information and contact technical support engineers.

----End

Related Information

None

2.13 0xF0CE0007 Engine Or Disk Enclosure Temperature IsBelow The Lower Limit

Description

The working temperature of an engine or disk enclosure is below the lower limit.

Attribute

ID Event Level Automatically Cleared

0xF0CE0007 Major Yes

Impact on the System

The normal operation of the storage system is adversely affected.

Possible Causes

The ambient temperature is below the lower limit.

Procedure

Step 1 Increase the existing air conditioners temperature or add more air conditioners. If the alarmpersists=>Step 2.

Step 2 Collect related information and contact technical support engineers.

----End

Related Information

None

OceanStor 5300 V3&5500 V3&5600 V3&5800 V3&6800V3 Storage SystemEvent Reference 2 Troubleshooting Events

Issue 04 (2015-06-10) Huawei Proprietary and ConfidentialCopyright © Huawei Technologies Co., Ltd.

22

2.14 0xF0CE0008 Engine Temperature Exceeds The UpperLimit

Description

The working temperature of an engine exceeds the upper limit.

Attribute

ID Event Level Automatically Cleared

0xF0CE0008 Major Yes

Impact on the System

The normal operation of the storage system may be adversely affected.

Possible Causes

l Fan modules are faulty.

l Heat dissipation channels are blocked.

l The ambient temperature exceeds the upper limit.

Procedure

Step 1 Check whether alarms are generated indicating fan module faults.

1. If yes, replace the faulty fan modules. If alarm Engine Temperature Exceeds the UpperLimit persists=>Step 2.

2. If no=>Step 2.

Step 2 Check whether heat dissipation channels are blocked.

1. If yes, clear the heat dissipation channels. If alarm Engine Temperature Exceeds the UpperLimit persists=>Step 3.

2. If no=>Step 3.

Step 3 Check whether the ambient temperature is too high.

1. If yes, lower the existing air conditioners temperature or add more air conditioners. If alarmEngine Temperature Exceeds the Upper Limit persists=>Step 4.

2. If no=>Step 4.

Step 4 Collect related information and contact technical support engineers.

----End

OceanStor 5300 V3&5500 V3&5600 V3&5800 V3&6800V3 Storage SystemEvent Reference 2 Troubleshooting Events

Issue 04 (2015-06-10) Huawei Proprietary and ConfidentialCopyright © Huawei Technologies Co., Ltd.

23

Related InformationNone

2.15 0xF0CE0009 Engine Temperature Is Far Beyond TheUpper Limit

DescriptionThe working temperature of an engine exceeds the upper limit.

Attribute

ID Event Level Automatically Cleared

0xF0CE0009 Critical Yes

Impact on the SystemThe normal operation of the storage system may be adversely affected.

Possible Causesl Fan modules are faulty.l Heat dissipation channels are blocked.l The ambient temperature exceeds the upper limit.

Procedure

Step 1 Check whether alarms are generated indicating fan module faults.1. If yes, replace the faulty fan modules. If alarm Engine Temperature Is Far Beyond the Upper

Limit persists=>Step 2.2. If no=>Step 2.

Step 2 Check whether heat dissipation channels are blocked.1. If yes, clear the heat dissipation channels. If alarm Engine Temperature Is Far Beyond the

Upper Limit persists=>Step 3.2. If no=>Step 3.

Step 3 Check whether the ambient temperature is too high.1. If yes, lower the existing air conditioners temperature or add more air conditioners. If alarm

Engine Temperature Is Far Beyond the Upper Limit persists=>Step 4.2. If no=>Step 4.

Step 4 Collect related information and contact technical support engineers.

----End

OceanStor 5300 V3&5500 V3&5600 V3&5800 V3&6800V3 Storage SystemEvent Reference 2 Troubleshooting Events

Issue 04 (2015-06-10) Huawei Proprietary and ConfidentialCopyright © Huawei Technologies Co., Ltd.

24

Related Information

None

2.16 0xF00CE0015 Failed To Monitor An Engine

Description

An engine failed to be monitored.

Attribute

ID Event Level Automatically Cleared

0xF00CE0015 Critical Yes

Impact on the System

The storage system cannot report engine faults, causing fault rectification to be delayed.

Possible Causes

l The engine is powered off.

l The engine fails to be powered on.

l All controllers of the engine are faulty.

l The engine ports that connect to other engines and switches are faulty.

Procedure

Step 1 Check the power supplies of the engine.

1. If any power cable of the engine is removed, insert the power cable and power on the engine.If the alarm persists=>Step 1.2.

2. If any power module of the engine is faulty, replace the faulty power module and poweron the engine. If the alarm persists=>Step 2.

3. If all power supplies of the engine are normal=>Step 2.

Step 2 Check the engine state.

1. If the running indicator on the engine keeps blinking for over 10 minutes=>Step 5.

2. If the engine enters safe mode=>Step 5.

3. If the engine is powered on correctly=>Step 3.

Step 3 Check whether alarms are generated indicating the faults of controllers in the engine.

1. If yes, replace the faulty controllers. If alarm Failed to Monitor an Engine persists=>Step4.

2. If no=>Step 4.

OceanStor 5300 V3&5500 V3&5600 V3&5800 V3&6800V3 Storage SystemEvent Reference 2 Troubleshooting Events

Issue 04 (2015-06-10) Huawei Proprietary and ConfidentialCopyright © Huawei Technologies Co., Ltd.

25

Step 4 Check whether the engine is correctly cabled to other engines and switches.

1. If no, cable the engine with other engines and switches correctly. If alarm Failed to Monitoran Engine persists=>Step 5.

2. If yes=>Step 5.

Step 5 Collect related information and contact technical support engineers.

----End

Related Information

None

2.17 0xF00CE0018 Controller Failed To Monitor An EngineRear Panel

Description

A controller failed to monitor an engine rear panel.

Attribute

ID Event Level Automatically Cleared

0xF00CE0018 Critical Yes

Impact on the System

The controller cannot report engine faults.

Possible Causes

l The I2C communication is abnormal.

l Engine rear panels are faulty.

Procedure

Step 1 Replace the controller. If the alarm persists=>Step 2.

Step 2 Collect related information and contact technical support engineers.

----End

Related Information

None

OceanStor 5300 V3&5500 V3&5600 V3&5800 V3&6800V3 Storage SystemEvent Reference 2 Troubleshooting Events

Issue 04 (2015-06-10) Huawei Proprietary and ConfidentialCopyright © Huawei Technologies Co., Ltd.

26

2.18 0xF00CE001D Expansion Ports Are Working AtInconsistent Rates

Description

Expansion ports are working at inconsistent rates.

Attribute

ID Event Level Automatically Cleared

0xF00CE001D Warning Yes

Impact on the System

N/A.

Possible Causes

The expansion ports are working at inconsistent rates.

Procedure

Step 1 Replace the cable of the expansion port of a lower rate. If the alarm persists=>Step 2.

Step 2 Replace the expansion module connected to the expansion port of a lower rate. If the alarmpersists=>Step 3.

Step 3 Collect related information and contact technical support engineers.

----End

Related Information

None

2.19 0xF00CE002A Disk Enclosure Is Working In SingleLink State

Description

A disk enclosure is working in single link state.

OceanStor 5300 V3&5500 V3&5600 V3&5800 V3&6800V3 Storage SystemEvent Reference 2 Troubleshooting Events

Issue 04 (2015-06-10) Huawei Proprietary and ConfidentialCopyright © Huawei Technologies Co., Ltd.

27

Attribute

ID Event Level Automatically Cleared

0xF00CE002A Major Yes

Impact on the System

A disk enclosure working in single link state may go offline.

Possible Causes

l Expansion cables are incorrectly connected or removed.

l Expansion modules are incorrectly inserted or removed.

l Expansion cables are damaged.

l Expansion modules are faulty.

Procedure

Step 1 Check expansion cables and expansion modules.

1. If any expansion cable or expansion module is removed, reinsert it. If the alarmpersists=>Step 1.2.

2. Replace the expansion cables. If the alarm persists=>Step 1.3.

3. Replace the expansion modules. If the alarm persists=>Step 2.

Step 2 Collect related information and contact technical support engineers.

----End

Related Information

None

2.20 0xF0CF0006 Controller Is Removed

Description

A controller is removed.

Attribute

ID Event Level Automatically Cleared

0xF0CF0006 Major Yes

OceanStor 5300 V3&5500 V3&5600 V3&5800 V3&6800V3 Storage SystemEvent Reference 2 Troubleshooting Events

Issue 04 (2015-06-10) Huawei Proprietary and ConfidentialCopyright © Huawei Technologies Co., Ltd.

28

Impact on the System

The system performance deteriorates and data loss may occur.

Possible Causes

The controller is removed.

Procedure

Step 1 Check whether the controller is removed.

1. If yes, reinsert the controller. If the alarm persists=>Step 2.

2. If no=>Step 2.

Step 2 Check whether the controller is firmly inserted.

1. If no, reinsert the controller correctly. If the alarm persists=>Step 3.

2. If yes=>Step 3.

Step 3 Collect related information and contact technical support engineers.

----End

Related Information

None

2.21 0xF00CF0014 Failed To Monitor The Controller

Description

The controller failed to be monitored.

Attribute

ID Event Level Automatically Cleared

0xF00CF0014 Critical Yes

Impact on the System

The storage system cannot report controller faults, causing fault rectification to be delayed.

Possible Causes

l The controller is restarting.

l The controller is faulty.

OceanStor 5300 V3&5500 V3&5600 V3&5800 V3&6800V3 Storage SystemEvent Reference 2 Troubleshooting Events

Issue 04 (2015-06-10) Huawei Proprietary and ConfidentialCopyright © Huawei Technologies Co., Ltd.

29

Procedure

Collect related information and contact technical support engineers.

----End

Related Information

None

2.22 0xF0CF0003 Controller Is Faulty

Description

Controller hardware is faulty.

Attribute

ID Event Level Automatically Cleared

0xF0CF0003 Major Yes

Impact on the System

The system performance is compromised and data may be lost.

Possible Causes

The components of the controller are faulty.

Procedure

Collect related information and contact technical support engineers.

----End

Related Information

None

2.23 0xF0CF0004 Incorrect Controller Memory Capacity

Description

The memory capacity is not supported.

OceanStor 5300 V3&5500 V3&5600 V3&5800 V3&6800V3 Storage SystemEvent Reference 2 Troubleshooting Events

Issue 04 (2015-06-10) Huawei Proprietary and ConfidentialCopyright © Huawei Technologies Co., Ltd.

30

Attribute

ID Event Level Automatically Cleared

0xF0CF0004 Major Yes

Impact on the SystemThe system performance deteriorates and data loss may occur.

Possible CausesMemory capacity of the controller does not meet system requirements.

Procedure

Collect related information and contact technical support engineers.

----End

Related InformationNone

2.24 0xF0CF0005 Abnormal Communication BetweenControllers

DescriptionThe communication between controllers in an engine is abnormal.

Attribute

ID Event Level Automatically Cleared

0xF0CF0005 Major Yes

Impact on the SystemThe normal operation of the storage system is not affected.

Possible Causesl Controller components are faulty.l Backplane components are faulty.

OceanStor 5300 V3&5500 V3&5600 V3&5800 V3&6800V3 Storage SystemEvent Reference 2 Troubleshooting Events

Issue 04 (2015-06-10) Huawei Proprietary and ConfidentialCopyright © Huawei Technologies Co., Ltd.

31

l Heartbeat connections are down.

l Mirrored links are down.

Procedure

Step 1 Replace any abnormal controller described in the alarm information. If the alarm persists=>Step2.

Step 2 Reinsert the removed controller and try another controller. If the alarm persists=>Step 3.

Step 3 Collect related information and contact technical support engineers to replace the engine.

----End

Related Information

None

2.25 0x100F0CF0032 Controller Power Failure

Description

A controller is powered off and the system is about to stop working.

Attribute

ID Event Level Automatically Cleared

0x100F0CF0032 Major Yes

Impact on the System

The controller is powered off and the system is about to stop working.

Possible Causes

l Power cables are incorrectly connected.

l Power cables loosen up or are damaged.

l No power is input.

l Power supplies are faulty.

Procedure

Step 1 Check whether power cables are correctly connected.

1. If yes=>Step 2.

2. If no, connect the power cables correctly. If the alarm persists=>Step 2.

OceanStor 5300 V3&5500 V3&5600 V3&5800 V3&6800V3 Storage SystemEvent Reference 2 Troubleshooting Events

Issue 04 (2015-06-10) Huawei Proprietary and ConfidentialCopyright © Huawei Technologies Co., Ltd.

32

Step 2 Check power cables.1. If any power cable is removed, reinsert it. If the alarm persists=>Step 2.2.2. Replace the power cable. If the alarm persists=>Step 3.

Step 3 Check whether external power is input correctly.1. If yes=>Step 4.2. If no, supply power to the storage system correctly. If the alarm persists=>Step 4.

Step 4 Check whether any power module is faulty.1. If yes, replace the faulty power module. If the alarm persists=>Step 5.2. If no=>Step 5.

Step 5 Collect related information and contact technical support engineers.

----End

Related InformationNone

2.26 0xF00CF0017 Incorrect Connection Between AController Port And A Switch Port

DescriptionA controller port is incorrectly connected to a switch port.

Attribute

ID Event Level Automatically Cleared

0xF00CF0017 Major Yes

Impact on the SystemThe application server cannot communicate correctly with the storage system.

Possible CausesThe two ports are incorrectly cabled.

Procedure

Step 1 Cable the switch port and the controller port correctly. If the alarm persists=>Step 2.

Step 2 Collect related information and contact technical support engineers.

----End

OceanStor 5300 V3&5500 V3&5600 V3&5800 V3&6800V3 Storage SystemEvent Reference 2 Troubleshooting Events

Issue 04 (2015-06-10) Huawei Proprietary and ConfidentialCopyright © Huawei Technologies Co., Ltd.

33

Related InformationNone

2.27 0x200F00CF0022 Failed To Start A Controller

DescriptionA user failed to start a controller.

Attribute

ID Event Level Automatically Cleared

0x200F00CF0022 Warning Yes

Impact on the SystemThe storage system cannot work correctly.

Possible CausesN/A.

Procedure

Collect related information and contact technical support engineers.

----End

Related InformationNone

2.28 0x100F00CF0027 Controller Restarts

DescriptionA controller restarts.

Attribute

ID Event Level Automatically Cleared

0x100F00CF0027 Major Yes

OceanStor 5300 V3&5500 V3&5600 V3&5800 V3&6800V3 Storage SystemEvent Reference 2 Troubleshooting Events

Issue 04 (2015-06-10) Huawei Proprietary and ConfidentialCopyright © Huawei Technologies Co., Ltd.

34

Impact on the System

N/A.

Possible Causes

l user power down/restart.

l Faults occur on the controller and it restarts to rectify the faults.

Procedure

If restart or power-off is triggered by the user, please ignore it. Otherwise, collect relatedinformation and contact technical support engineers.

----End

Related Information

None

2.29 0x100F00CF002A Controller Cache Failed To Flush Data

Description

Controller cache failed to flush data.

Attribute

ID Event Level Automatically Cleared

0x100F00CF002A Major Yes

Impact on the System

The reliability of the storage system deteriorates.

Possible Causes

The controller is running incorrectly.

Procedure

Collect related information and contact technical support engineers.

----End

OceanStor 5300 V3&5500 V3&5600 V3&5800 V3&6800V3 Storage SystemEvent Reference 2 Troubleshooting Events

Issue 04 (2015-06-10) Huawei Proprietary and ConfidentialCopyright © Huawei Technologies Co., Ltd.

35

Related Information

None

2.30 0x100F00CF0034 A Controller Is Isolated

Description

A controller is isolated.

Attribute

ID Event Level Automatically Cleared

0x100F00CF0034 Critical Yes

Impact on the System

N/A.

Possible Causes

The PCIe link to the controller is down.

Procedure

Step 1 Check whether the device is connected through PCIe switch.

1. If yes=>Step 2.

2. If no=>Step 3.

Step 2 Check whether the cable connection is correct.

1. If yes=>The cable may be damaged, requiring a replacement. After the replacement, if thealarm persists=>Step 4.

2. If no=>Connect the cable correctly. After that, if the alarm persists=>Step 4.

Step 3 PCIe link connection problem occurs=>Step 4.

Step 4 Collect related information and contact technical support engineers.

----End

Related Information

None

OceanStor 5300 V3&5500 V3&5600 V3&5800 V3&6800V3 Storage SystemEvent Reference 2 Troubleshooting Events

Issue 04 (2015-06-10) Huawei Proprietary and ConfidentialCopyright © Huawei Technologies Co., Ltd.

36

2.31 0xF00CF0035 The System Is Abnormal

Description

The system is abnormal.

Attribute

ID Event Level Automatically Cleared

0xF00CF0035 Critical Yes

Impact on the System

The system is abnormal and cannot provide services.

Possible Causes

Controllers are faulty.

Procedure

Collect related information and contact technical support engineers.

----End

Related Information

None

2.32 0xF00CF0036 Controller Services Are Abnormal

Description

Controller services are abnormal.

Attribute

ID Event Level Automatically Cleared

0xF00CF0036 Critical Yes

OceanStor 5300 V3&5500 V3&5600 V3&5800 V3&6800V3 Storage SystemEvent Reference 2 Troubleshooting Events

Issue 04 (2015-06-10) Huawei Proprietary and ConfidentialCopyright © Huawei Technologies Co., Ltd.

37

Impact on the System

The controller cannot provide services.

Possible Causes

l Service recovery failed when the controller is being powered on.

l Service switchover failed before you replace the PCIe interface module online.

Procedure

Please collect log with Export Data button on DeviceManager and contact technical supportengineers.

----End

Related Information

None

2.33 0x100F00CF0037 Controller Is About To Restart

Description

A controller is about to restart.

Attribute

ID Event Level Automatically Cleared

0x100F00CF0037 Warning Yes

Impact on the System

N/A.

Possible Causes

The controller version does not meet system requirements.

Procedure

Collect related information and contact technical support engineers.

----End

OceanStor 5300 V3&5500 V3&5600 V3&5800 V3&6800V3 Storage SystemEvent Reference 2 Troubleshooting Events

Issue 04 (2015-06-10) Huawei Proprietary and ConfidentialCopyright © Huawei Technologies Co., Ltd.

38

Related Information

None

2.34 0xF0050001 Expansion Module Is Removed

Description

An expansion module is removed. As a result, a link between the disk enclosure that houses theexpansion module and another disk enclosure or an engine is down.

Attribute

ID Event Level Automatically Cleared

0xF0050001 Major Yes

Impact on the System

l If an expansion module is redundantly connected to a disk enclosure or an engine, theexpansion module removal will compromise storage system performance and reliability.

l If an expansion module is connected to a disk enclosure or an engine through only one link,the expansion module removal will fail data transmission between the expansion moduleand the disk enclosure or the engine.

Possible Causes

The expansion module is removed.

Procedure

Step 1 Reinsert the expansion module. If the alarm persists=>Step 2.

Step 2 Collect related information and contact technical support engineers.

----End

Related Information

None

2.35 0xF0050002 Expansion Module Is Not Inserted

Description

An expansion module is removed. As a result, a link between the disk enclosure that houses theexpansion module and another disk enclosure or an engine is down.

OceanStor 5300 V3&5500 V3&5600 V3&5800 V3&6800V3 Storage SystemEvent Reference 2 Troubleshooting Events

Issue 04 (2015-06-10) Huawei Proprietary and ConfidentialCopyright © Huawei Technologies Co., Ltd.

39

Attribute

ID Event Level Automatically Cleared

0xF0050002 Major Yes

Impact on the System

Data cannot be transferred between a removed expansion module and a disk enclosure or anengine.

Possible Causes

N/A.

Procedure

Step 1 Reinsert the expansion module. If the alarm persists=>Step 2.

Step 2 Collect related information and contact technical support engineers.

----End

Related Information

None

2.36 0xF0050003 Expansion Module Is Faulty

Description

Expansion module hardware is faulty.

Attribute

ID Event Level Automatically Cleared

0xF0050003 Major Yes

Impact on the System

l If an expansion module is redundantly connected to a disk enclosure or an engine, theexpansion module removal will compromise storage system performance and reliability.

l If an expansion module is connected to a disk enclosure or an engine through only one link,the expansion module removal will fail data transmission between the expansion moduleand the disk enclosure or the engine.

OceanStor 5300 V3&5500 V3&5600 V3&5800 V3&6800V3 Storage SystemEvent Reference 2 Troubleshooting Events

Issue 04 (2015-06-10) Huawei Proprietary and ConfidentialCopyright © Huawei Technologies Co., Ltd.

40

Possible Causes

The expansion module is faulty.

Procedure

Step 1 Replace the expansion module. If the alarm persists=>Step 2.

Step 2 Collect related information and contact technical support engineers.

----End

Related Information

None

2.37 0xF00D00014 Abnormal Communication BetweenExpansion Modules

Description

Communications between expansion modules are abnormal.

Attribute

ID Event Level Automatically Cleared

0xF00D00014 Major Yes

Impact on the System

Communications between expansion modules are abnormal.

Possible Causes

l Expansion modules are faulty.

l Engine or Disk enclosure backplanes are faulty.

Procedure

Step 1 Replace expansion module A. If the alarm persists=>Step 2.

Step 2 Replace expansion module B. If the alarm persists=>Step 3.

Step 3 Collect related information and contact technical support engineers.

----End

OceanStor 5300 V3&5500 V3&5600 V3&5800 V3&6800V3 Storage SystemEvent Reference 2 Troubleshooting Events

Issue 04 (2015-06-10) Huawei Proprietary and ConfidentialCopyright © Huawei Technologies Co., Ltd.

41

Related InformationNone

2.38 0xF00D00016 Expansion Module Is Incorrectly Cabled

DescriptionAn expansion module is incorrectly cabled.

Attribute

ID Event Level Automatically Cleared

0xF00D00016 Major Yes

Impact on the SystemCommunications between expansion modules are abnormal.

Possible CausesCables are incorrectly connected to the expansion module.

Procedure

Step 1 Recable the expansion module based on the cable connection rules provided in productdocuments. If the alarm persists=>Step 2.

Step 2 Collect related information and contact technical support engineers.

----End

Related InformationNone

2.39 0xF0D10001 Management Module Is Removed

DescriptionA management module is removed.

Attribute

ID Event Level Automatically Cleared

0xF0D10001 Major Yes

OceanStor 5300 V3&5500 V3&5600 V3&5800 V3&6800V3 Storage SystemEvent Reference 2 Troubleshooting Events

Issue 04 (2015-06-10) Huawei Proprietary and ConfidentialCopyright © Huawei Technologies Co., Ltd.

42

Impact on the System

l The reliability of the storage system deteriorates.

l The security of the storage system deteriorates.

Possible Causes

The management module is removed.

Procedure

Step 1 Reinsert the management module. If the alarm persists=>Step 2.

Step 2 Collect related information and contact technical support engineers.

----End

Related Information

None

2.40 0xF0D10002 Management Module Is Faulty

Description

Management module hardware is faulty.

Attribute

ID Event Level Automatically Cleared

0xF0D10002 Major Yes

Impact on the System

l The reliability of the storage system deteriorates.

l The security of the storage system deteriorates.

Possible Causes

l The management module is faulty.

l SSDs are faulty.

OceanStor 5300 V3&5500 V3&5600 V3&5800 V3&6800V3 Storage SystemEvent Reference 2 Troubleshooting Events

Issue 04 (2015-06-10) Huawei Proprietary and ConfidentialCopyright © Huawei Technologies Co., Ltd.

43

Procedure

Step 1 Replace the management module. If the alarm persists=>Step 2.

Step 2 Collect related information and contact technical support engineers.

----End

Related InformationNone

2.41 0xF0D10005 Interface Module Is Removed

DescriptionAn interface module is removed.

AttributeID Event Level Automatically Cleared

0xF0D10005 Major Yes

Impact on the SystemAll ports on the interface module fail to function.

Possible CausesThe interface module is removed.

Procedure

Step 1 Reinsert the interface module. If the alarm persists=>Step 2.

Step 2 Collect related information and contact technical support engineers.

----End

Related InformationNone

2.42 0xF0D10006 Interface Module Is Faulty

DescriptionInterface module hardware is faulty.

OceanStor 5300 V3&5500 V3&5600 V3&5800 V3&6800V3 Storage SystemEvent Reference 2 Troubleshooting Events

Issue 04 (2015-06-10) Huawei Proprietary and ConfidentialCopyright © Huawei Technologies Co., Ltd.

44

Attribute

ID Event Level Automatically Cleared

0xF0D10006 Major Yes

Impact on the System

All ports on the interface module fail to function.

Possible Causes

The interface module is faulty.

Procedure

Step 1 Replace the interface module. If the alarm persists=>Step 2.

Step 2 Collect related information and contact technical support engineers.

----End

Related Information

None

2.43 0xF0D10008 Interface Module Is Unrecognizable

Description

The storage system failed to identify an interface module in an engine or a disk enclosure.

Attribute

ID Event Level Automatically Cleared

0xF0D10008 Major Yes

Impact on the System

The interface module cannot work correctly.

Possible Causes

l The interface module is damaged.

l An incorrect interface module is inserted.

OceanStor 5300 V3&5500 V3&5600 V3&5800 V3&6800V3 Storage SystemEvent Reference 2 Troubleshooting Events

Issue 04 (2015-06-10) Huawei Proprietary and ConfidentialCopyright © Huawei Technologies Co., Ltd.

45

Procedure

Step 1 Replace the interface module. If the alarm persists=>Step 2.

Step 2 Collect related information and contact technical support engineers.

----End

Related Information

None

2.44 0xF0D10009 Interface Module Temperature ExceedsThe Upper Limit

Description

The working temperature of an interface module exceeds the upper limit due to ambienttemperature increase or fan faults.

Attribute

ID Event Level Automatically Cleared

0xF0D10009 Warning Yes

Impact on the System

Services on the interface module may be abnormal.

Possible Causes

l The ambient temperature exceeds the upper limit.

l Fan modules are faulty.

l The interface module is faulty.

Procedure

Step 1 Check whether alarms are generated indicating the overheating of the enclosure that houses theinterface module.

1. If yes, handle alarms with recommended actions. If alarm Interface Module TemperatureExceeds the Upper Limit persists=>Step 2.

2. If no=>Step 2.

Step 2 Check whether alarms are generated for fan modules of the enclosure that houses the interfacemodule.

OceanStor 5300 V3&5500 V3&5600 V3&5800 V3&6800V3 Storage SystemEvent Reference 2 Troubleshooting Events

Issue 04 (2015-06-10) Huawei Proprietary and ConfidentialCopyright © Huawei Technologies Co., Ltd.

46

1. If yes, handle alarms with recommended actions. If alarm Interface Module TemperatureExceeds the Upper Limit persists=>Step 3.

2. If no=>Step 3.

Step 3 Check whether alarms are generated indicating interface module faults.

1. If yes, replace the faulty interface modules. If alarm Interface Module Temperature Exceedsthe Upper Limit persists=>Step 4.

Step 4 Collect related information and contact technical support engineers.

----End

Related Information

None

2.45 0xF0D1000A Incorrect Removal Of Interface Module

Description

An interface module is removed unexpectedly.

Attribute

ID Event Level Automatically Cleared

0xF0D1000A Critical Yes

Impact on the System

Controllers may not work correctly.

Possible Causes

l The interface module is removed without following a correct process.

l The interface module is damaged.

Procedure

Step 1 Check whether the interface module is removed based on a correct hot swap process.

1. If yes=>Step 2.

2. If no, reinsert the interface module. If the system still cannot identify the interface module,restart related controllers. If the alarm persists=>Step 2.

Step 2 Check whether alarms are generated indicating interface module faults.

1. If yes, replace the faulty interface modules. If the alarm persists=>Step 3.

2. If no=>Step 3.

OceanStor 5300 V3&5500 V3&5600 V3&5800 V3&6800V3 Storage SystemEvent Reference 2 Troubleshooting Events

Issue 04 (2015-06-10) Huawei Proprietary and ConfidentialCopyright © Huawei Technologies Co., Ltd.

47

Step 3 Collect related information and contact technical support engineers.

----End

Related Information

None

2.46 0xF010A0017 The Communication Between ControllerAnd Management Module Is Disconnected

Description

The communication between controller and management module is disconnected.

Attribute

ID Event Level Automatically Cleared

0xF010A0017 Major Yes

Impact on the System

N/A.

Possible Causes

l The management module is faulty.

l The controller is faulty.

l Engine rear panels are faulty.

Procedure

Step 1 Replace the faulty management module. If the alarm persists=>Step 2.

Step 2 Replace the faulty controller. If the alarm persists=>Step 3.

Step 3 Replace the faulty engine rear panels. If the alarm persists=>Step 4.

Step 4 Collect related information and contact technical support engineers.

----End

Related Information

None

OceanStor 5300 V3&5500 V3&5600 V3&5800 V3&6800V3 Storage SystemEvent Reference 2 Troubleshooting Events

Issue 04 (2015-06-10) Huawei Proprietary and ConfidentialCopyright © Huawei Technologies Co., Ltd.

48

2.47 0xF00D1001E The System Failed To Monitor AnInterface Module

Description

The system failed to monitor an interface module.

Attribute

ID Event Level Automatically Cleared

0xF00D1001E Major Yes

Impact on the System

N/A.

Possible Causes

l The interface module is faulty.

l The I2C communication is abnormal.

Procedure

Step 1 Check whether alarms are generated indicating interface module faults.

1. If yes, replace the faulty interface modules. If the alarm persists=>Step 2.

2. If no=>Step 2.

Step 2 Replace related controllers. If the alarm persists=>Step 3.

Step 3 Collect related information and contact technical support engineers.

----End

Related Information

None

2.48 0xF00A0001 Disk Is Faulty

Description

Disk hardware is faulty.

OceanStor 5300 V3&5500 V3&5600 V3&5800 V3&6800V3 Storage SystemEvent Reference 2 Troubleshooting Events

Issue 04 (2015-06-10) Huawei Proprietary and ConfidentialCopyright © Huawei Technologies Co., Ltd.

49

Attribute

ID Event Level Automatically Cleared

0xF00A0001 Critical Yes

Impact on the Systeml Storage pools will degrade, causing storage system I/O performance deterioration and

possible data loss.l Storage pools will become faulty, causing storage pool data loss and service interruption.

Possible CausesThe disk is faulty.

Procedure

Step 1 Replace the disk. If the alarm persists=>Step 2.

Step 2 Collect related information and contact technical support engineers.

----End

Related InformationNone

2.49 0xF00A0002 Unrecognizable Disk

DescriptionA disk is not authenticated.

Attribute

ID Event Level Automatically Cleared

0xF00A0002 Warning Yes

Impact on the SystemThe disk cannot function correctly.

Possible CausesThe disk is not authenticated.

OceanStor 5300 V3&5500 V3&5600 V3&5800 V3&6800V3 Storage SystemEvent Reference 2 Troubleshooting Events

Issue 04 (2015-06-10) Huawei Proprietary and ConfidentialCopyright © Huawei Technologies Co., Ltd.

50

Procedure

Step 1 Replace the disk. If the alarm persists=>Step 2.

Step 2 Collect related information and contact technical support engineers.

----End

Related Information

None

2.50 0xF00A0003 Disk Is About To Fail

Description

A disk is about to fail.

Attribute

ID Event Level Automatically Cleared

0xF00A0003 Major Yes

Impact on the System

If a disk about to fail is a member of a storage pool, the storage pool may degrade.

Possible Causes

The disk is about to fail.

Procedure

Step 1 Check whether it is a member disk.

1. If yes, pre-copy the disk, and replace the disk after a message is displayed indicating thatthe precopy succeeds. If the alarm persists=>Step 2.

2. If no, replace the disk. If the alarm persists=>Step 2.

Step 2 Collect related information and contact technical support engineers.

----End

Related Information

None

OceanStor 5300 V3&5500 V3&5600 V3&5800 V3&6800V3 Storage SystemEvent Reference 2 Troubleshooting Events

Issue 04 (2015-06-10) Huawei Proprietary and ConfidentialCopyright © Huawei Technologies Co., Ltd.

51

2.51 0xF00A0004 Disk Temperature Exceeds The UpperLimit

Description

The working temperature of a disk exceeds the upper limit due to overheated ambienttemperature or fan module faults.

Attribute

ID Event Level Automatically Cleared

0xF00A0004 Warning Yes

Impact on the System

The disk may become faulty.

Possible Causes

l The disk is overheated.

l The heat dissipation system is faulty.

Procedure

Step 1 Check whether alarms are generated indicating the overheating of the disk enclosure that housesthe disk.

1. If yes, lower the existing air conditioners temperature or add more air conditioners. If alarmDisk Temperature Exceeds the Upper Limit persists=>Step 2.

2. If no=>Step 2.

Step 2 Check whether alarms are generated indicating the faults of fan modules in the disk enclosurethat houses the disk.

1. If yes, replace the faulty fan modules. If alarm Disk Temperature Exceeds the Upper Limitpersists=>Step 3.

2. If no=>Step 4.

Step 3 Check whether heat dissipation channels are blocked.

1. If yes, clear the heat dissipation channels. If alarm Disk Temperature Exceeds the UpperLimit persists=>Step 4.

2. If no=>Step 4.

Step 4 Collect related information and contact technical support engineers.

----End

OceanStor 5300 V3&5500 V3&5600 V3&5800 V3&6800V3 Storage SystemEvent Reference 2 Troubleshooting Events

Issue 04 (2015-06-10) Huawei Proprietary and ConfidentialCopyright © Huawei Technologies Co., Ltd.

52

Related Information

None

2.52 0xF00A0008 Coffer Disk Is Faulty

Description

A coffer disk is faulty.

Attribute

ID Event Level Automatically Cleared

0xF00A0008 Major Yes

Impact on the System

There is a higher risk of data loss.

Possible Causes

l The coffer disk is faulty.

l The coffer disk is removed.

Procedure

Step 1 Check whether any coffer disk is removed.

1. If yes, insert a coffer disk. The newly inserted coffer disk must be of the same capacity andtype as other existing coffer disks. If alarm Coffer Disk Is Faulty persists=>Step 2.

2. If no=>Step 2.

Step 2 Check whether alarms are generated indicating disk faults.

1. If yes, replace the faulty disks. If alarm Coffer Disk Is Faulty persists=>Step 3.

2. If no=>Step 3.

Step 3 Collect related information and contact technical support engineers.

----End

Related Information

None

OceanStor 5300 V3&5500 V3&5600 V3&5800 V3&6800V3 Storage SystemEvent Reference 2 Troubleshooting Events

Issue 04 (2015-06-10) Huawei Proprietary and ConfidentialCopyright © Huawei Technologies Co., Ltd.

53

2.53 0xF00A000A Coffer Disks Not Found

Description

No coffer disks are found in the storage system. As a result, the storage system failed to start.

Attribute

ID Event Level Automatically Cleared

0xF00A000A Critical Yes

Impact on the System

There is a higher risk of data loss.

Possible Causes

l The disk enclosure that houses coffer disks is not powered on.

l Coffer disks are faulty.

l Coffer disks are removed.

l The expansion cables of the disk enclosure that houses coffer disks are incorrectlyconnected.

Procedure

Step 1 Check whether the disk enclosure that houses coffer disks is powered on.

1. If no, power on the disk enclosure. If alarm No Coffer Disks Found persists=>Step 2.

2. If yes=Step 2.

Step 2 Check whether alarms are generated indicating coffer disk faults.

1. If yes, replace the faulty coffer disks. If alarm No Coffer Disks Found persists=>Step 3.

2. If no=>Step 3.

Step 3 Check whether coffer disks are correctly inserted.

1. If no, reinsert the coffer disks. If alarm No Coffer Disks Found persists=>Step 4.

2. If yes=>Step 4.

Step 4 Check whether the expansion cables of the disk enclosure that houses coffer disks are correctlyconnected to an engine.

1. If no, connect the expansion cables correctly. If alarm No Coffer Disks Foundpersists=>Step 5.

2. If yes=>Step 5.

OceanStor 5300 V3&5500 V3&5600 V3&5800 V3&6800V3 Storage SystemEvent Reference 2 Troubleshooting Events

Issue 04 (2015-06-10) Huawei Proprietary and ConfidentialCopyright © Huawei Technologies Co., Ltd.

54

Step 5 Collect related information and contact technical support engineers.

----End

Related Information

None

2.54 0xF000A0015 The System Failed To Monitor A Disk InA Disk Enclosure

Description

The system failed to monitor a disk in a disk enclosure.

Attribute

ID Event Level Automatically Cleared

0xF000A0015 Major Yes

Impact on the System

The storage system cannot report disk enclosure faults, causing fault rectification to be delayed.

Possible Causes

l The disk is faulty.

l The disk is loosely inserted into its slot.

l Expansion modules are faulty.

l Disk enclosure backplanes are faulty.

Procedure

Step 1 Check whether alarms are generated indicating disk faults.

1. If yes, replace the faulty disks. If alarm The System Failed to Monitor a Diskpersists=>Step 2.

2. If no=>Step 2.

Step 2 Check whether the disk is firmly inserted into its slot.

1. If no, reinsert the disk correctly. If alarm The System Failed to Monitor a Diskpersists=>Step 3.

2. If yes=>Step 3.

Step 3 Check whether alarms are generated indicating expansion module faults.

OceanStor 5300 V3&5500 V3&5600 V3&5800 V3&6800V3 Storage SystemEvent Reference 2 Troubleshooting Events

Issue 04 (2015-06-10) Huawei Proprietary and ConfidentialCopyright © Huawei Technologies Co., Ltd.

55

1. If yes, replace the faulty expansion modules. If alarm The System Failed to Monitor a Diskpersists=>Step 4.

2. If no=>Step 4.

Step 4 Collect related information and contact technical support engineers.

----End

Related Information

None

2.55 0xF00A000D Slow Disk Response

Description

A disk responds slowly.

Attribute

ID Event Level Automatically Cleared

0xF00A000D Major Yes

Impact on the System

The storage pool that houses the disk may have compromised I/O performance or even degrade.

Possible Causes

l The disk is faulty.

l Expansion ports are partially damaged.

l The disk is incorrectly inserted into its slot.

l Expansion modules are faulty.

l Disk enclosure backplanes are faulty.

Procedure

Step 1 Check whether alarms are generated indicating disk faults.

1. If yes, replace the faulty disks. If alarm Slow Disk Response persists=>Step 2.

2. If no=>Step 2.

Step 2 Check whether any expansion port is faulty.

1. If yes, replace the interface module where the faulty port resides. If alarm Slow DiskResponse persists=>Step 3.

2. If no=>Step 3.

OceanStor 5300 V3&5500 V3&5600 V3&5800 V3&6800V3 Storage SystemEvent Reference 2 Troubleshooting Events

Issue 04 (2015-06-10) Huawei Proprietary and ConfidentialCopyright © Huawei Technologies Co., Ltd.

56

Step 3 Check whether the disk is firmly inserted.

1. If no, reinsert the disk. If alarm Slow Disk Response persists=>Step 4.

2. If yes=>Step 4.

Step 4 Check whether alarms are generated indicating expansion module faults.

1. If yes, replace the faulty expansion modules. If alarm Slow Disk Response persists=>Step5.

2. If no=>Step 5.

Step 5 Collect related information and contact technical support engineers.

----End

Related Information

None

2.56 0xF00A000E Incompatible Disk Model

Description

The model of a disk is incompatible with the storage system.

Attribute

ID Event Level Automatically Cleared

0xF00A000E Major Yes

Impact on the System

The disk cannot be detected by the storage system.

Possible Causes

The disk model is incompatible with the storage system.

Procedure

Step 1 Replace the disk with a qualified one. If the alarm persists=>Step 2.

Step 2 Collect related information and contact technical support engineers.

----End

Related Information

None

OceanStor 5300 V3&5500 V3&5600 V3&5800 V3&6800V3 Storage SystemEvent Reference 2 Troubleshooting Events

Issue 04 (2015-06-10) Huawei Proprietary and ConfidentialCopyright © Huawei Technologies Co., Ltd.

57

2.57 0xF00A000C Disk Is In Single Link State

Description

A disk is in single-link state.

Attribute

ID Event Level Automatically Cleared

0xF00A000C Major Yes

Impact on the System

N/A.

Possible Causes

The disk is in single-link state.

Procedure

Step 1 Replace the disk. If the alarm persists=>Step 2.

Step 2 Collect related information and contact technical support engineers.

----End

Related Information

None

2.58 0xF00A0006 Disk Has Too Many Bit Error

Description

A disk has too many bit errors.

Attribute

ID Event Level Automatically Cleared

0xF00A0006 Major Yes

OceanStor 5300 V3&5500 V3&5600 V3&5800 V3&6800V3 Storage SystemEvent Reference 2 Troubleshooting Events

Issue 04 (2015-06-10) Huawei Proprietary and ConfidentialCopyright © Huawei Technologies Co., Ltd.

58

Impact on the System

N/A.

Possible Causes

l The disk has too many bit errors.

l Cables or ports are damaged.

l The disk is incorrectly inserted into its slot.

l Expansion modules are faulty.

l Disk enclosure backplanes are faulty.

Procedure

Step 1 Replace the disk. If alarm Disk Has Too Many Bit Errors persists=>Step 2.

Step 2 Check whether alarms are generated indicating the partial damage of expansion ports.

1. If yes, replace the interface modules where the faulty expansion ports reside. If alarm DiskHas Too Many Bit Errors persists=>Step 3.

2. If no=>Step 3.

Step 3 Check whether the disk is firmly inserted.

1. If yes=>Step 4.

2. If no, reinsert the disk. If alarm Disk Has Too Many Bit Errors persists=>Step 4.

Step 4 Check whether alarms are generated indicating expansion module faults.

1. If yes, replace the faulty expansion modules. If alarm Disk Has Too Many Bit Errorspersists=>Step 5.

2. If no=>Step 5.

Step 5 Collect related information and contact technical support engineers.

----End

Related Information

None

2.59 0xF000A001A Disk Temperature Is Below The LowerLimit

Description

The working temperature of a disk is below the lower limit.

OceanStor 5300 V3&5500 V3&5600 V3&5800 V3&6800V3 Storage SystemEvent Reference 2 Troubleshooting Events

Issue 04 (2015-06-10) Huawei Proprietary and ConfidentialCopyright © Huawei Technologies Co., Ltd.

59

AttributeID Event Level Automatically Cleared

0xF000A001A Warning Yes

Impact on the Systeml The reliability of the storage system deteriorates.l The storage system may not work correctly.

Possible Causesl The ambient temperature is too low.l The disk is faulty.

Procedure

Step 1 Check whether alarms are generated indicating the overcooling of the disk enclosure that housesthe disk.1. If yes, increase the existing air conditioners temperature or add more air conditioners. If

alarm Disk Temperature Is Below the Lower Limit persists=>Step 2.2. If no=>Step 2.

Step 2 Check whether alarms are generated indicating disk faults.1. If yes, replace the faulty disks. If the alarm Disk Temperature Is Below the Lower Limit

persists=>Step 3.

Step 3 Collect related information and contact technical support engineers.

----End

Related InformationNone

2.60 0xF000A004E Coffer Disks Not Found

DescriptionCoffer disks are not found in disk enclosure.

AttributeID Event Level Automatically Cleared

0xF000A004E Critical Yes

OceanStor 5300 V3&5500 V3&5600 V3&5800 V3&6800V3 Storage SystemEvent Reference 2 Troubleshooting Events

Issue 04 (2015-06-10) Huawei Proprietary and ConfidentialCopyright © Huawei Technologies Co., Ltd.

60

Impact on the System

The storage system to fail to start.

Possible Causes

l The disk enclosure that houses coffer disks is not powered on.

l Coffer disks are faulty.

l Coffer disks are removed.

l The expansion cables of the disk enclosure that houses coffer disks are incorrectlyconnected.

Procedure

Step 1 Check whether the disk enclosure that houses coffer disks is powered on.

1. If no, power on the disk enclosure. If alarm Coffer Disk Not Found persists=>Step 2.

2. If yes=>Step 2.

Step 2 Check whether alarms are generated indicating coffer disk faults.

1. If yes, replace the faulty coffer disks. If alarm Coffer Disk Not Found persists=>Step 3.

2. If no=>Step 3.

Step 3 Check whether any coffer disk is removed.

1. If no, insert the removed coffer disk. If alarm Coffer Disk Not Found persists=>Step 4.

2. If no=>Step 4.

Step 4 Check whether the expansion cables between the disk enclosure that houses coffer disks and anengine are correctly connected.

1. If yes=>Step 5.

2. If no, connect the expansion cables correctly. If alarm Coffer Disk Not Foundpersists=>Step 5.

Step 5 Collect related information and contact technical support engineers.

----End

Related Information

None

2.61 0xF000A004F The Coffer Disk Is Inserted Into AnIncorrect Slot

Description

The coffer disk is inserted into an incorrect slot.

OceanStor 5300 V3&5500 V3&5600 V3&5800 V3&6800V3 Storage SystemEvent Reference 2 Troubleshooting Events

Issue 04 (2015-06-10) Huawei Proprietary and ConfidentialCopyright © Huawei Technologies Co., Ltd.

61

Attribute

ID Event Level Automatically Cleared

0xF000A004F Major No

Impact on the System

N/A.

Possible Causes

The coffer disk is not inserted into its original slot.

Procedure

Reinsert the coffer disk into the correct slot. Ensure that the coffer disk is inserted into its originalslot.

----End

Related Information

None

2.62 0xF0170001 Power Module Is Not Inserted

Description

A power module is not inserted.

Attribute

ID Event Level Automatically Cleared

0xF0170001 Major Yes

Impact on the System

l The reliability of the storage system deteriorates.

l The storage system may not work correctly.

Possible Causes

The power module is not inserted.

OceanStor 5300 V3&5500 V3&5600 V3&5800 V3&6800V3 Storage SystemEvent Reference 2 Troubleshooting Events

Issue 04 (2015-06-10) Huawei Proprietary and ConfidentialCopyright © Huawei Technologies Co., Ltd.

62

Procedure

Step 1 Check whether the power module is inserted.

1. If yes=>Step 2.

2. If no, insert a power module. If the alarm persists=>Step 2.

Step 2 Check whether the power module is firmly inserted.

1. If yes=>Step 3.

2. If no, reinsert the power module correctly. If the alarm persists=>Step 3.

Step 3 Collect related information and contact technical support engineers.

----End

Related Information

None

2.63 0xF0170002 Power Module Is Removed

Description

A power module is removed.

Attribute

ID Event Level Automatically Cleared

0xF0170002 Major Yes

Impact on the System

l The reliability of the storage system deteriorates.

l The storage system may not work correctly.

Possible Causes

The power module is removed.

Procedure

Step 1 Insert the power module. If the alarm persists=>Step 2.

Step 2 Collect related information and contact technical support engineers.

----End

OceanStor 5300 V3&5500 V3&5600 V3&5800 V3&6800V3 Storage SystemEvent Reference 2 Troubleshooting Events

Issue 04 (2015-06-10) Huawei Proprietary and ConfidentialCopyright © Huawei Technologies Co., Ltd.

63

Related Information

None

2.64 0xF0170003 Power Module Is Faulty

Description

A power module is faulty.

Attribute

ID Event Level Automatically Cleared

0xF0170003 Major Yes

Impact on the System

l The reliability of the storage system deteriorates.

l The storage system may not work correctly.

Possible Causes

The power module is faulty.

Procedure

Step 1 1 Check whether the power cable is securely connected to the power module involved in thealarm. If not, securely connect the power cable. If the alarm persists==>Step 2.

Step 2 Replace the power module. If the alarm persists=>Step 3.

Step 3 Collect related information and contact technical support engineers.

----End

Related Information

None

2.65 0xF0170004 Power Module Temperature Exceeds TheUpper Limit

Description

The temperature of a power module exceeds the upper limit.

OceanStor 5300 V3&5500 V3&5600 V3&5800 V3&6800V3 Storage SystemEvent Reference 2 Troubleshooting Events

Issue 04 (2015-06-10) Huawei Proprietary and ConfidentialCopyright © Huawei Technologies Co., Ltd.

64

AttributeID Event Level Automatically Cleared

0xF0170004 Warning Yes

Impact on the Systeml The reliability of the storage system deteriorates.l The storage system may not work correctly.

Possible Causesl The ambient temperature exceeds the upper limit.l Fan modules are faulty.l The power module is faulty.

Procedure

Step 1 Check whether alarms are generated indicating the overheating of the disk enclosure or enginethat houses power module.1. If yes, lower the existing air conditioners temperature or add more air conditioners. If alarm

Power Module Temperature Exceeds the Upper Limit persists=>Step 2.2. If no=>Step 2.

Step 2 Check whether alarms are generated indicating fan module faults.1. If yes, replace the faulty fan modules. If alarm Power Module Temperature Exceeds the

Upper Limit persists=>Step 3.2. If no=>Step 3.

Step 3 Check whether alarms are generated indicating power module faults.1. If yes, replace the faulty power modules. If alarm Power Module Temperature Exceeds the

Upper Limit persists=>Step 4.2. If no=>Step 4.

Step 4 Collect related information and contact technical support engineers.

----End

Related InformationNone

2.66 0xF0170005 Power Module Input Is Abnormal

DescriptionThe input to a power module is abnormal.

OceanStor 5300 V3&5500 V3&5600 V3&5800 V3&6800V3 Storage SystemEvent Reference 2 Troubleshooting Events

Issue 04 (2015-06-10) Huawei Proprietary and ConfidentialCopyright © Huawei Technologies Co., Ltd.

65

Attribute

ID Event Level Automatically Cleared

0xF0170005 Major Yes

Impact on the System

l The reliability of the storage system deteriorates.l The storage system may not work correctly.

Possible Causes

l Power cables are removed or damaged.l The input voltage is too high or too low.l The power module is faulty.

Procedure

Step 1 Check the power cables connected to the power module.1. If any power cable is removed, reinsert the power cable. If alarm Input to a Power Module

Is Abnormal persists=>Step 1.2.2. Replace the power cable. If alarm Power Module Input Is Abnormal persists=>Step 2.

Step 2 Check whether the input power voltage is too high or too low.1. If yes, stabilize the input power voltage. If alarm Power Module Input Is Abnormal

persists=>Step 3.2. If no=>Step 3.

Step 3 Check whether alarms are generated indicating power module faults.1. If yes, replace the faulty power modules. If alarm Power Module Input Is Abnormal

persists=>Step 4.2. If no=>Step 4.

Step 4 Collect related information and contact technical support engineers.

----End

Related InformationNone

2.67 0xF00170014 Power Module Has No Input

DescriptionThere is no power input to a power module.

OceanStor 5300 V3&5500 V3&5600 V3&5800 V3&6800V3 Storage SystemEvent Reference 2 Troubleshooting Events

Issue 04 (2015-06-10) Huawei Proprietary and ConfidentialCopyright © Huawei Technologies Co., Ltd.

66

Attribute

ID Event Level Automatically Cleared

0xF00170014 Major Yes

Impact on the System

The storage system fails to start.

Possible Causes

l Power cables are incorrectly connected.

l Power cables are removed or damaged.

l The power module is incorrectly inserted.

l No external power is input.

l The power module is faulty.

Procedure

Step 1 Check whether power cables are connected correctly.

1. If yes=>Step 2.

2. If no, connect the power cables correctly. If the alarm persists=>Step 2.

Step 2 Check power cables.

1. If any power cable is removed, reinsert it. If the alarm persists=>Step 2.2.

2. Replace the power cable. If the alarm persists=>Step 3.

Step 3 Check whether the power module is inserted.

1. If yes=>Step 4.

2. If no, reinsert the power module. If the alarm persists=>Step 4.

Step 4 Check whether any external power is input to the power module.

1. If yes=>Step 5.

2. If no, supply power to the storage system correctly. If the alarm persists=>Step 5.

Step 5 Replace the power module. If the alarm persists=>Step 6.

Step 6 Collect related information and contact technical support engineers.

----End

Related Information

None

OceanStor 5300 V3&5500 V3&5600 V3&5800 V3&6800V3 Storage SystemEvent Reference 2 Troubleshooting Events

Issue 04 (2015-06-10) Huawei Proprietary and ConfidentialCopyright © Huawei Technologies Co., Ltd.

67

2.68 0xF00170017 The System Failed To Monitor A PowerModule

Description

The system failed to monitor a power module.

Attribute

ID Event Level Automatically Cleared

0xF00170017 Major Yes

Impact on the System

The system failed to monitor a power module.

Possible Causes

l The power module is faulty.

l The I2C communication is abnormal.

Procedure

Step 1 Check whether alarms are generated indicating power module faults.1. If yes, replace the faulty power modules. If alarm The System Failed to Monitor a Power

Module persists=>Step 2.2. If no=>Step 2.

Step 2 Replace the controller of the engine that houses the power module. If alarm The System Failedto Monitor a Power Module persists=>Step 3.

Step 3 Collect related information and contact technical support engineers.

----End

Related Information

None

2.69 0x100F0170006 Power Module Incompatible

Description

A power module is incompatible with the storage system.

OceanStor 5300 V3&5500 V3&5600 V3&5800 V3&6800V3 Storage SystemEvent Reference 2 Troubleshooting Events

Issue 04 (2015-06-10) Huawei Proprietary and ConfidentialCopyright © Huawei Technologies Co., Ltd.

68

Attribute

ID Event Level Automatically Cleared

0x100F0170006 Warning Yes

Impact on the System

The storage system fails to start.

Possible Causes

N/A.

Procedure

Collect related information and contact technical support engineers.

----End

Related Information

None

2.70 0x100F0170008 Multi-Vendor Power Modules In TheSame Enclosure

Description

Power modules in the same enclosure are from different vendors.

Attribute

ID Event Level Automatically Cleared

0x100F0170008 Warning Yes

Impact on the System

The storage system fails to start.

Possible Causes

N/A.

OceanStor 5300 V3&5500 V3&5600 V3&5800 V3&6800V3 Storage SystemEvent Reference 2 Troubleshooting Events

Issue 04 (2015-06-10) Huawei Proprietary and ConfidentialCopyright © Huawei Technologies Co., Ltd.

69

Procedure

Collect related information and contact technical support engineers.

----End

Related InformationNone

2.71 0xF0D20002 BBU Module Is Faulty

DescriptionA BBU module is faulty.

Attribute

ID Event Level Automatically Cleared

0xF0D20002 Major Yes

Impact on the SystemThe reliability of the storage system deteriorates.

Possible CausesN/A.

Procedure

Step 1 Replace the BBU module. If the alarm persists=>Step 2.

Step 2 Collect related information and contact technical support engineers.

----End

Related InformationNone

OceanStor 5300 V3&5500 V3&5600 V3&5800 V3&6800V3 Storage SystemEvent Reference 2 Troubleshooting Events

Issue 04 (2015-06-10) Huawei Proprietary and ConfidentialCopyright © Huawei Technologies Co., Ltd.

70

2.72 0xF0D20003 BBU Module Reaches Its Expiration DateOr Is Aging

Description

A BBU module reaches its expiration date or is aging.

Attribute

ID Event Level Automatically Cleared

0xF0D20003 Major Yes

Impact on the System

The reliability of the storage system deteriorates.

Possible Causes

The BBU module reaches its expiration date or is aging.

Procedure

Step 1 Replace the BBU module. If the alarm persists=>Step 2.

Step 2 Collect related information and contact technical support engineers.

----End

Related Information

None

2.73 0xF0D20007 BBU Module Is About To Expire

Description

A BBU module is about to expire.

Attribute

ID Event Level Automatically Cleared

0xF0D20007 Warning Yes

OceanStor 5300 V3&5500 V3&5600 V3&5800 V3&6800V3 Storage SystemEvent Reference 2 Troubleshooting Events

Issue 04 (2015-06-10) Huawei Proprietary and ConfidentialCopyright © Huawei Technologies Co., Ltd.

71

Impact on the System

The reliability of the storage system deteriorates.

Possible Causes

The BBU module is about to expire.

Procedure

Step 1 Replace the BBU module in three months. If the alarm persists=>Step 2.

Step 2 Collect related information and contact technical support engineers.

----End

Related Information

None

2.74 0xF0D20004 BBU Module Is Removed

Description

A BBU module is removed.

Attribute

ID Event Level Automatically Cleared

0xF0D20004 Major Yes

Impact on the System

The reliability of the storage system deteriorates.

Possible Causes

The BBU module is removed.

Procedure

Step 1 Insert the BBU module. If the alarm persists=>Step 2.

Step 2 Collect related information and contact technical support engineers.

----End

OceanStor 5300 V3&5500 V3&5600 V3&5800 V3&6800V3 Storage SystemEvent Reference 2 Troubleshooting Events

Issue 04 (2015-06-10) Huawei Proprietary and ConfidentialCopyright © Huawei Technologies Co., Ltd.

72

Related Information

None

2.75 0xF0D20005 BBU Module Temperature Exceeds TheUpper Limit

Description

The working temperature of the BBU module exceeds the upper limit.

Attribute

ID Event Level Automatically Cleared

0xF0D20005 Major Yes

Impact on the System

The reliability of the storage system deteriorates.

Possible Causes

l The ambient temperature exceeds the upper limit.

l Fan modules are faulty.

l The BBU module is faulty.

Procedure

Step 1 Check whether alarms are generated indicating the overheating of the engine that houses theBBU module.

1. If yes, lower the existing air conditioners temperature or add more air conditioners. If alarmBBU Module Temperature Exceeds the Upper Limit persists=>Step 2.

2. If no=>Step 2.

Step 2 Check whether alarms are generated indicating the faults of fan modules in the engine that housesthe BBU module.

1. If yes, replace the faulty fan modules. If alarm BBU Module Temperature Exceeds theUpper Limit persists=>Step 3.

2. If no=>Step 3.

Step 3 Check whether alarms are generated indicating BBU module faults.

1. If yes, replace the faulty BBU modules. If alarm BBU Module Temperature Exceeds theUpper Limit persists=>Step 4.

2. If no=>Step 4.

OceanStor 5300 V3&5500 V3&5600 V3&5800 V3&6800V3 Storage SystemEvent Reference 2 Troubleshooting Events

Issue 04 (2015-06-10) Huawei Proprietary and ConfidentialCopyright © Huawei Technologies Co., Ltd.

73

Step 4 Collect related information and contact technical support engineers.

----End

Related Information

None

2.76 0xF00D2001B BBU Module Temperature Is Below TheLower Limit

Description

The working temperature of a BBU module is below the lower limit.

Attribute

ID Event Level Automatically Cleared

0xF00D2001B Major Yes

Impact on the System

The reliability of the storage system deteriorates.

Possible Causes

l The ambient temperature is below the lower limit.

l The BBU module is faulty.

Procedure

Step 1 Check whether alarms are generated indicating the overcooling of the engine that houses theBBU module.

1. If yes, increase the existing air conditioners temperature or add more air conditioners. Ifalarm BBU Module Temperature Is Below the Lower Limit persists=>Step 2.

2. If no=>Step 2.

Step 2 Check whether alarms are generated indicating BBU module faults.

1. If yes, replace the faulty BBU modules. If alarm BBU Module Temperature Is Below theLower Limit persists=>Step 3.

2. If no=>Step 3.

Step 3 Collect related information and contact technical support engineers.

----End

OceanStor 5300 V3&5500 V3&5600 V3&5800 V3&6800V3 Storage SystemEvent Reference 2 Troubleshooting Events

Issue 04 (2015-06-10) Huawei Proprietary and ConfidentialCopyright © Huawei Technologies Co., Ltd.

74

Related InformationNone

2.77 0xF00D20014 The System Failed To Monitor A BBUModule

DescriptionThe system failed to monitor a BBU module.

Attribute

ID Event Level Automatically Cleared

0xF00D20014 Major Yes

Impact on the SystemN/A.

Possible Causesl The BBU module is faulty.l The I2C communication is abnormal.

Procedure

Step 1 Check whether alarms are generated indicating BBU module faults.1. If yes, replace the faulty BBU modules. If the alarm persists=>Step 2.2. If no=>Step 2.

Step 2 Replace the controller of the engine that houses the BBU module. If the alarm persists=>Step3.

Step 3 Collect related information and contact technical support engineers.

----End

Related InformationNone

OceanStor 5300 V3&5500 V3&5600 V3&5800 V3&6800V3 Storage SystemEvent Reference 2 Troubleshooting Events

Issue 04 (2015-06-10) Huawei Proprietary and ConfidentialCopyright © Huawei Technologies Co., Ltd.

75

2.78 0xF0D30001 Fan Module Is Faulty

DescriptionFan hardware is faulty, causing abnormal fan speed.

Attribute

ID Event Level Automatically Cleared

0xF0D30001 Major Yes

Impact on the Systeml Engines or disk enclosures will overheat, affecting the normal operation of the storage

system.l The storage I/O performance may deteriorate.

Possible CausesThe fan module is faulty.

Procedure

Step 1 Replace the fan module. If the alarm persists=>Step 2.

Step 2 Collect related information and contact technical support engineers.

----End

Related InformationNone

2.79 0xF0D30002 Fan Module Is Not Inserted

DescriptionA fan module is not inserted.

Attribute

ID Event Level Automatically Cleared

0xF0D30002 Major Yes

OceanStor 5300 V3&5500 V3&5600 V3&5800 V3&6800V3 Storage SystemEvent Reference 2 Troubleshooting Events

Issue 04 (2015-06-10) Huawei Proprietary and ConfidentialCopyright © Huawei Technologies Co., Ltd.

76

Impact on the System

l Engines or disk enclosures will overheat, affecting the normal operation of the storagesystem.

l The storage I/O performance may deteriorate.

Possible Causes

The fan module is not inserted.

Procedure

Step 1 Check whether the fan module is inserted.

1. If yes=>Step 2.

2. If no, insert a fan module. If the alarm persists=>Step 2.

Step 2 Check whether the fan module is firmly inserted.

1. If yes=>Step 3.

2. If no, reinsert the fan module correctly. If the alarm persists=>Step 3.

Step 3 Collect related information and contact technical support engineers.

----End

Related Information

None

2.80 0xF0D30003 Fan Module Is Removed

Description

A fan module is removed.

Attribute

ID Event Level Automatically Cleared

0xF0D30003 Major Yes

Impact on the System

l Engines or disk enclosures will overheat, affecting the normal operation of the storagesystem.

l The storage I/O performance may deteriorate.

OceanStor 5300 V3&5500 V3&5600 V3&5800 V3&6800V3 Storage SystemEvent Reference 2 Troubleshooting Events

Issue 04 (2015-06-10) Huawei Proprietary and ConfidentialCopyright © Huawei Technologies Co., Ltd.

77

Possible CausesThe fan module is removed.

Procedure

Step 1 Insert the fan module. If the alarm persists=>Step 2.

Step 2 Collect related information and contact technical support engineers.

----End

Related InformationNone

2.81 0xF00D30014 The System Failed To Monitor A FanModule

DescriptionThe system failed to monitor a fan module.

AttributeID Event Level Automatically Cleared

0xF00D30014 Major Yes

Impact on the SystemN/A.

Possible Causesl The fan module is faulty.l The I2C communication is abnormal.

Procedure

Step 1 Check whether alarms are generated indicating fan module faults.1. If yes, replace the faulty fan modules. If the alarm persists=>Step 2.2. If no=>Step 2.

Step 2 Replace the controller of the engine that houses the fan module. If the alarm persists=>Step 3.

Step 3 Collect related information and contact technical support engineers.

----End

OceanStor 5300 V3&5500 V3&5600 V3&5800 V3&6800V3 Storage SystemEvent Reference 2 Troubleshooting Events

Issue 04 (2015-06-10) Huawei Proprietary and ConfidentialCopyright © Huawei Technologies Co., Ltd.

78

Related Information

None

2.82 0xF0060002 Expansion Port Link Down

Description

A link between an expansion module and a disk enclosure or engine is down.

Attribute

ID Event Level Automatically Cleared

0xF0060002 Major Yes

Impact on the System

l If an expansion module is redundantly connected to a disk enclosure or an engine, theexpansion port link down will compromise storage system performance and reliability.

l If an expansion module is connected to a disk enclosure or an engine through only one link,the expansion port link down will fail data transmission between the expansion module andthe disk enclosure or the engine.

Possible Causes

l Expansion cables are removed or damaged.

l Disk enclosures are offline.

l Expansion modules are faulty.

Procedure

Step 1 Check expansion cables.

1. If any expansion cable is removed, reinsert it. If alarm Expansion Port Link Downpersists=>Step 1.2.

2. Replace the expansion cable. If the alarm persists=>Step 2.

Step 2 Check whether alarms are generated indicating disk enclosure offline.

1. If yes, handle alarms with recommended actions. If alarm Expansion Port Link Downpersists=>Step 3.

2. If no=>Step 3.

Step 3 Check whether alarms are generated indicating expansion module faults.

1. If yes, replace the faulty expansion modules. If alarm Expansion Port Link Downpersists=>Step 4.

2. If no=>Step 4.

OceanStor 5300 V3&5500 V3&5600 V3&5800 V3&6800V3 Storage SystemEvent Reference 2 Troubleshooting Events

Issue 04 (2015-06-10) Huawei Proprietary and ConfidentialCopyright © Huawei Technologies Co., Ltd.

79

Step 4 Collect related information and contact technical support engineers.

----End

Related InformationNone

2.83 0xF0060003 Expansion Port Is Faulty

DescriptionAn expansion module fault causes an expansion port to be unavailable.

Attribute

ID Event Level Automatically Cleared

0xF0060003 Major Yes

Impact on the Systeml If an expansion module is redundantly connected to a disk enclosure or an engine, the

expansion port link down will compromise storage system performance and reliability.l If an expansion module is connected to a disk enclosure or an engine through only one link,

the expansion port link down will fail data transmission between the expansion module andthe disk enclosure or the engine.

Possible CausesThe expansion port is faulty.

Procedure

Step 1 Replace the module where the expansion port resides. If the alarm persists=>Step 2.

Step 2 Collect related information and contact technical support engineers.

----End

Related InformationNone

OceanStor 5300 V3&5500 V3&5600 V3&5800 V3&6800V3 Storage SystemEvent Reference 2 Troubleshooting Events

Issue 04 (2015-06-10) Huawei Proprietary and ConfidentialCopyright © Huawei Technologies Co., Ltd.

80

2.84 0xF0060004 Host Port Link Down

Description

A host port is disconnected from the application server or other devices.

Attribute

ID Event Level Automatically Cleared

0xF0060004 Major Yes

Impact on the System

The application server or other devices cannot communicate with the storage system throughthe host port.

Possible Causes

l The cables are removed or damaged.

l The optical module of a port is faulty.

Procedure

Step 1 Check whether the cable connected to the host port is removed or damaged.

1. If the cable is removed, connect it back. If the alarm persists=>Step 1.2.

2. If the cable is damaged, replace it with an intact one. If the alarm persists=>Step 1.3.

3. If the host port has an optical module=>Step 2. Otherwise=>Step 1.4.

4. If no exception is found=>Step 3.

Step 2 Check whether the optical module is faulty.

1. Reinsert the optical module and connect the cable. If the alarm persists=>Step 2.2.

2. Replace the optical module and connect the cable. If the alarm persists=>Step 3.

Step 3 Check the port configuration.

1. Check whether the topological mode of the local port matches that of the peer end. If not,change the mode to match the two ends. If the alarm persists after this operation =>Step3.2.

2. Check whether the speed of the local port matches that of the peer end. If not, change themode to match the two ends. If the alarm persists after this operation =>Step 4.

Step 4 Contact technical support engineers for further handling.

----End

OceanStor 5300 V3&5500 V3&5600 V3&5800 V3&6800V3 Storage SystemEvent Reference 2 Troubleshooting Events

Issue 04 (2015-06-10) Huawei Proprietary and ConfidentialCopyright © Huawei Technologies Co., Ltd.

81

Related Information

None

2.85 0xF0060005 Host Port Is Faulty

Description

A host port is faulty.

Attribute

ID Event Level Automatically Cleared

0xF0060005 Major Yes

Impact on the System

The application server or other devices cannot communicate with the storage system throughthe host port.

Possible Causes

The host port is faulty.

Procedure

Collect related information and contact technical support engineers.

----End

Related Information

None

2.86 0xF0060006 Expansion Port Partially Damaged

Description

An expansion module is partially damaged.

Attribute

ID Event Level Automatically Cleared

0xF0060006 Major Yes

OceanStor 5300 V3&5500 V3&5600 V3&5800 V3&6800V3 Storage SystemEvent Reference 2 Troubleshooting Events

Issue 04 (2015-06-10) Huawei Proprietary and ConfidentialCopyright © Huawei Technologies Co., Ltd.

82

Impact on the Systeml If an expansion module is redundantly connected to a disk enclosure or an engine, the

expansion port link down will compromise storage system performance and reliability.l If an expansion module is connected to a disk enclosure or an engine through only one link,

the expansion port link down will fail data transmission between the expansion module andthe disk enclosure or the engine.

Possible Causesl Expansion cables are removed or faulty, causing bit errors to occur.l The expansion port is faulty.

Procedure

Step 1 Check expansion cables.1. If any expansion cable is removed, reinsert it and wait three minutes. If the alarm

persists=>Step 1.2.2. Replace the expansion cable. If the alarm persists=>Step 2.

Step 2 Replace the module where the expansion port resides. If the alarm persists=>Step 3.

Step 3 Collect related information and contact technical support engineers.

----End

Related InformationNone

2.87 0xF01080014 Expansion Port Has Too Many Bit Errors

DescriptionAn expansion port has too many bit errors.

Attribute

ID Event Level Automatically Cleared

0xF01080014 Major Yes

Impact on the SystemData cannot be transferred between the storage system and disk enclosures through the expansionport.

OceanStor 5300 V3&5500 V3&5600 V3&5800 V3&6800V3 Storage SystemEvent Reference 2 Troubleshooting Events

Issue 04 (2015-06-10) Huawei Proprietary and ConfidentialCopyright © Huawei Technologies Co., Ltd.

83

Possible Causes

l Expansion cables are loosen up or damaged.

l The expansion port is faulty.

l Expansion modules are faulty.

Procedure

Step 1 Check expansion cables.

1. If any expansion cable is not firmly inserted, reinsert it. If the alarm persists=>Step 1.2.

2. Replace the expansion cable. If the alarm persists=>Step 2.

Step 2 Replace faulty modules where the faulty expansion port resides. If the alarm persists=>Step 3.

Step 3 Collect related information and contact technical support engineers.

----End

Related Information

None

2.88 0xF0060010 Expansion Port Isolated

Description

An expansion port on an engine or disk enclosure is isolated.

Attribute

ID Event Level Automatically Cleared

0xF0060010 Major Yes

Impact on the System

The expansion port is isolated and becomes unavailable.

Possible Causes

l Expansion cables loosen up or are damaged, causing bit errors.

l The expansion port is faulty.

Procedure

Step 1 Check whether any expansion cable is faulty.

1. If yes, replace the faulty expansion cable. If the alarm persists=>Step 2.

OceanStor 5300 V3&5500 V3&5600 V3&5800 V3&6800V3 Storage SystemEvent Reference 2 Troubleshooting Events

Issue 04 (2015-06-10) Huawei Proprietary and ConfidentialCopyright © Huawei Technologies Co., Ltd.

84

2. If no=>Step 2.

Step 2 Check whether expansion cables are firmly inserted.

1. If yes=>Step 3.

2. If no, reinsert the expansion cables and wait three minutes. If the alarm persists=>Step 3.

Step 3 Replace the module where the expansion port resides. If the alarm persists=>Step 4.

Step 4 Collect related information and contact technical support engineers.

----End

Related Information

None

2.89 0xF01080015 Host Port Has Too Many Bit Errors

Description

A host port has too many bit errors.

Attribute

ID Event Level Automatically Cleared

0xF01080015 Major Yes

Impact on the System

The application server or other devices cannot communicate with the storage system throughthe host port.

Possible Causes

l Cables are loosen up or damaged.

l The port is faulty.

l Interface modules are faulty.

Procedure

Step 1 Check cables.

1. If any cable is not firmly inserted, reinsert it. If the alarm persists=>Step 1.2.

2. Replace the cable. If the alarm persists=>Step 2.

Step 2 Check whether any optical module is on the host port and the host ports peer port.

1. If yes, replace the optical modules. If the alarm persists=>Step 3.

OceanStor 5300 V3&5500 V3&5600 V3&5800 V3&6800V3 Storage SystemEvent Reference 2 Troubleshooting Events

Issue 04 (2015-06-10) Huawei Proprietary and ConfidentialCopyright © Huawei Technologies Co., Ltd.

85

2. If no=>Step 3.

Step 3 Replace the interface modules that house the host port and its peer port. If the alarmpersists=>Step 4.

Step 4 Collect related information and contact technical support engineers.

----End

Related Information

None

2.90 0xF01080016 PCIE Port Partially Damaged

Description

A PCIe port is partially damaged but still works.

Attribute

ID Event Level Automatically Cleared

0xF01080016 Major Yes

Impact on the System

N/A.

Possible Causes

l The PCIe cables are removed or damaged, causing bit errors.

l The PCIe port is faulty.

Procedure

Step 1 Check PCIe cables.

1. If any PCIe cable is removed, reinsert it. If the alarm persists=>Step 1.2.

2. Replace the PCIe cable. If the alarm persists=>Step 2.

Step 2 Collect related information and contact technical support engineers.

----End

Related Information

None

OceanStor 5300 V3&5500 V3&5600 V3&5800 V3&6800V3 Storage SystemEvent Reference 2 Troubleshooting Events

Issue 04 (2015-06-10) Huawei Proprietary and ConfidentialCopyright © Huawei Technologies Co., Ltd.

86

2.91 0xF01080018 PCIE Port Is Faulty

Description

A PCIe port is faulty.

Attribute

ID Event Level Automatically Cleared

0xF01080018 Major Yes

Impact on the System

The interface module where the port resides cannot provide services.

Possible Causes

The PCIe port is faulty.

Procedure

Step 1 Replace the interface module where the PCIe port resides. If the alarm persists=>Step 2.

Step 2 Collect related information and contact technical support engineers.

----End

Related Information

None

2.92 0xF01080019 PCIE Port Disconnected

Description

A PCIe port is disconnected.

Attribute

ID Event Level Automatically Cleared

0xF01080019 Major Yes

OceanStor 5300 V3&5500 V3&5600 V3&5800 V3&6800V3 Storage SystemEvent Reference 2 Troubleshooting Events

Issue 04 (2015-06-10) Huawei Proprietary and ConfidentialCopyright © Huawei Technologies Co., Ltd.

87

Impact on the System

N/A.

Possible Causes

PCIe cables are removed or damaged.

Procedure

Step 1 Check PCIe cables.

1. If any PCIe cable is removed, reinsert it. If the alarm persists=>Step 1.2.

2. Replace the PCIe cable. If the alarm persists=>Step 2.

Step 2 Collect related information and contact technical support engineers.

----End

Related Information

None

2.93 0xF0108001A PCIE Port Has Too Many Bit Errors

Description

A PCIe port has too many bit errors but still works.

Attribute

ID Event Level Automatically Cleared

0xF0108001A Major Yes

Impact on the System

N/A.

Possible Causes

The PCIe port has too many bit errors.

Procedure

Collect related information and contact technical support engineers.

----End

OceanStor 5300 V3&5500 V3&5600 V3&5800 V3&6800V3 Storage SystemEvent Reference 2 Troubleshooting Events

Issue 04 (2015-06-10) Huawei Proprietary and ConfidentialCopyright © Huawei Technologies Co., Ltd.

88

Related Information

None

2.94 0xF0060011 Network Port Is Working In Half-DuplexMode

Description

A network port is working in half-duplex mode.

Attribute

ID Event Level Automatically Cleared

0xF0060011 Major Yes

Impact on the System

N/A.

Possible Causes

l The host or switch where the network ports peer port resides supports only half-duplex.

l Expansion cables loosen up or are damaged.

l Network port components are faulty.

Procedure

Step 1 Check the working mode of the network ports peer port.

1. If the peer port is working in half-duplex mode, change the working mode to full-duplex.If the alarm persists=>Step 1.2.

2. If the peer port supports only half-duplex mode, adjust network connections to ensure thatfull-duplex is supported. If the alarm persists=>Step 2.

3. If the peer port meets requirements=>Step 2.

Step 2 Check cables.

1. If any cable is removed, reinsert it. If the alarm persists=>Step 2.2.

2. Replace the cable. If the alarm persists=>Step 3.

Step 3 Replace the module where the network port resides. If the alarm persists=>Step 4.

Step 4 Collect related information and contact technical support engineers.

----End

OceanStor 5300 V3&5500 V3&5600 V3&5800 V3&6800V3 Storage SystemEvent Reference 2 Troubleshooting Events

Issue 04 (2015-06-10) Huawei Proprietary and ConfidentialCopyright © Huawei Technologies Co., Ltd.

89

Related Information

None

2.95 0xF0108001D Port Negotiated Rate Is Smaller Than TheAllowed Maximum

Description

The negotiated rate of a port is smaller than the allowed maximum.

Attribute

ID Event Level Automatically Cleared

0xF0108001D Major Yes

Impact on the System

The interface module where the port resides cannot provide services.

Possible Causes

l The rate supported by the network ports peer port is smaller than that of the network port.

l Expansion cables are removed or damaged.

l Network port components are faulty.

Procedure

Step 1 Check whether the speed supported by the network ports peer port is smaller than that of thenetwork port.

1. If yes, ignore this alarm.

2. If no=>Step 2.

Step 2 Check expansion cables.

1. If any expansion cable is removed, reinsert it. If the alarm persists=>Step 2.2.

2. Replace the expansion cable. If the alarm persists=>Step 3.

Step 3 Check whether any optical module is installed.

1. If no=>Step 4.

2. If yes, replace the optical modules on the network port and its peer port. If the alarmpersists=>Step 3.3.

3. Replace the interface modules where the network port and its peer port reside. If the alarmpersists=>Step 4.

OceanStor 5300 V3&5500 V3&5600 V3&5800 V3&6800V3 Storage SystemEvent Reference 2 Troubleshooting Events

Issue 04 (2015-06-10) Huawei Proprietary and ConfidentialCopyright © Huawei Technologies Co., Ltd.

90

Step 4 Collect related information and contact technical support engineers.

----End

Related Information

None

2.96 0xF01080048 Management Network Port Is Faulty

Description

A management network port is faulty.

Attribute

ID Event Level Automatically Cleared

0xF01080048 Major Yes

Impact on the System

Storage devices cannot be managed or maintained through a faulty management network port.

Possible Causes

Management network port hardware is faulty.

Procedure

Collect related information and contact technical support engineers.

----End

Related Information

None

2.97 0xF01080049 Management Network Port IsDisconnected

Description

A management network port is disconnected.

OceanStor 5300 V3&5500 V3&5600 V3&5800 V3&6800V3 Storage SystemEvent Reference 2 Troubleshooting Events

Issue 04 (2015-06-10) Huawei Proprietary and ConfidentialCopyright © Huawei Technologies Co., Ltd.

91

Attribute

ID Event Level Automatically Cleared

0xF01080049 Warning Yes

Impact on the System

Storage devices cannot be managed or maintained through a disconnected management networkport.

Possible Causes

Management network cables are removed or damaged.

Procedure

Step 1 Check management network cables.

1. If any management network cable is removed, reinsert it. If the alarm persists=>Step 1.2.

2. Replace the management network cable. If the alarm persists=>Step 2.

Step 2 Collect related information and contact technical support engineers.

----End

Related Information

None

2.98 0xF0EA0003 Port Optical Module Is Faulty

Description

The optical module of a port is faulty.

Attribute

ID Event Level Automatically Cleared

0xF0EA0003 Major Yes

Impact on the System

The optical module cannot provide services.

OceanStor 5300 V3&5500 V3&5600 V3&5800 V3&6800V3 Storage SystemEvent Reference 2 Troubleshooting Events

Issue 04 (2015-06-10) Huawei Proprietary and ConfidentialCopyright © Huawei Technologies Co., Ltd.

92

Possible CausesThe optical module is faulty.

Procedure

Step 1 Replace the optical module with a new one that meets requirements. If the alarm persists=>Step2.

Step 2 Collect related information and contact technical support engineers.

----End

Related InformationNone

2.99 0xF0EA0004 Port Unavailable Due To IncompatibleOptical Module Type

DescriptionThe type of an optical module is incompatible with its port, causing the port to be unavailable.

AttributeID Event Level Automatically Cleared

0xF0EA0004 Warning Yes

Impact on the SystemThe optical module cannot provide services.

Possible CausesA single-mode optical module is inserted into the port.

Procedure

Step 1 Replace the single-mode optical module with a multi-mode optical module. If the alarmpersists=>Step 2.

Step 2 Collect related information and contact technical support engineers.

----End

Related InformationNone

OceanStor 5300 V3&5500 V3&5600 V3&5800 V3&6800V3 Storage SystemEvent Reference 2 Troubleshooting Events

Issue 04 (2015-06-10) Huawei Proprietary and ConfidentialCopyright © Huawei Technologies Co., Ltd.

93

2.100 0xF0EA0005 Optical Module Rate Is Inconsistent WithThat Of Its Port

Description

The rate of an optical module is inconsistent with that of its port, causing the port to beunavailable.

Attribute

ID Event Level Automatically Cleared

0xF0EA0005 Major Yes

Impact on the System

The optical module cannot provide services.

Possible Causes

The rate of the optical module is different from that of its port.

Procedure

Step 1 Replace the optical module with a new one that meets requirements. If the alarm persists=>Step2.

Step 2 Collect related information and contact technical support engineers.

----End

Related Information

None

2.101 0xF00EA0016 Optical Module Temperature Is BelowThe Lower Limit

Description

The temperature of an optical module is below the lower limit.

OceanStor 5300 V3&5500 V3&5600 V3&5800 V3&6800V3 Storage SystemEvent Reference 2 Troubleshooting Events

Issue 04 (2015-06-10) Huawei Proprietary and ConfidentialCopyright © Huawei Technologies Co., Ltd.

94

Attribute

ID Event Level Automatically Cleared

0xF00EA0016 Major Yes

Impact on the SystemN/A.

Possible Causesl The ambient temperature is too low.l The optical module is faulty.

Procedure

Step 1 Check whether alarms are generated indicating the overcooling of the engine or enclosure thathouses the optical module.1. If yes, increase the existing air conditioners temperature or add more air conditioners. If

alarm Optical Module Temperature Is Below the Lower Limit persists=>Step 2.2. If no=>Step 2.

Step 2 Check whether alarms are generated indicating optical module faults.1. If yes, replace the faulty optical modules. If alarm Optical Module Temperature Is Below

the Lower Limit persists=>Step 3.2. If no=>Step 3.

Step 3 Collect related information and contact technical support engineers.

----End

Related InformationNone

2.102 0xF00EA0014 Abnormal Port Link

DescriptionThe link to a port housing an optical module is down due to the link down between the host portand the application server or another device, a fault on the optical module, or a fault on the port.

Attribute

ID Event Level Automatically Cleared

0xF00EA0014 Major Yes

OceanStor 5300 V3&5500 V3&5600 V3&5800 V3&6800V3 Storage SystemEvent Reference 2 Troubleshooting Events

Issue 04 (2015-06-10) Huawei Proprietary and ConfidentialCopyright © Huawei Technologies Co., Ltd.

95

Impact on the SystemThe application server or other devices cannot communicate with the storage system throughthe host port.

Possible Causesl The cable connected to the optical module is not firmly inserted or damaged.l The optical module or its peer port is faulty.l The port or its peer port is faulty.

Procedure

Step 1 Check cable connections.1. If any cable is not firmly inserted, reinsert it. If the alarm persists=>Step 1.2.2. Replace the cable. If the alarm persists=>Step 2.

Step 2 Replace the optical module of the port and that of the ports peer port. If the alarmpersists=>Step 3.

Step 3 Replace the modules where the port and its peer port reside. If the alarm persists=>Step 4.

Step 4 Collect related information and contact technical support engineers.

----End

Related InformationNone

2.103 0xF00EA0015 The System Failed To Monitor AnOptical Module

DescriptionThe system failed to monitor an optical module.

AttributeID Event Level Automatically Cleared

0xF00EA0015 Major Yes

Impact on the SystemN/A.

OceanStor 5300 V3&5500 V3&5600 V3&5800 V3&6800V3 Storage SystemEvent Reference 2 Troubleshooting Events

Issue 04 (2015-06-10) Huawei Proprietary and ConfidentialCopyright © Huawei Technologies Co., Ltd.

96

Possible Causes

l The optical module is faulty.

l The I2C communication is abnormal.

Procedure

Step 1 Check whether alarms are generated indicating optical module faults.1. If yes, replace the optical modules. If the alarm persists=>Step 2.2. If no=>Step 2.

Step 2 Replace the module where the optical module resides. If the alarm persists=>Step 3.

Step 3 Collect related information and contact technical support engineers.

----End

Related Information

None

2.104 0xF00EA0017 Optical Module Temperature ExceedsThe Upper Limit

Description

The temperature of an optical module exceeds the upper limit.

Attribute

ID Event Level Automatically Cleared

0xF00EA0017 Major Yes

Impact on the System

N/A.

Possible Causes

l The heat dissipation system is faulty.

l The optical module is faulty.

Procedure

Step 1 Check whether alarms are generated indicating the overheating of the engine or enclosure thathouses the optical module.

OceanStor 5300 V3&5500 V3&5600 V3&5800 V3&6800V3 Storage SystemEvent Reference 2 Troubleshooting Events

Issue 04 (2015-06-10) Huawei Proprietary and ConfidentialCopyright © Huawei Technologies Co., Ltd.

97

1. If yes, lower the existing air conditioners temperature or add more air conditioners. If alarmOptical Module Temperature Exceeds the Upper Limit persists=>Step 2.

2. If no=>Step 2.

Step 2 Check whether alarms are generated indicating the faults of fan modules in the engine orenclosure that houses the optical module.

1. If yes, replace the faulty fan modules. If alarm Optical Module Temperature Exceeds theUpper Limit persists=>Step 3.

2. If no=>Step 3.

Step 3 Replace the optical module. If alarm Optical Module Temperature Exceeds the Upper Limitpersists=>Step 4.

Step 4 Collect related information and contact technical support engineers.

----End

Related Information

None

2.105 0xF00B0001 LUN Is Faulty

Description

If a storage system works in single-storage pool state and bad sectors are detected by a hostduring data read, the storage system reports a LUN fault.

Attribute

ID Event Level Automatically Cleared

0xF00B0001 Critical Yes

Impact on the System

Data on a faulty LUN may be lost.

Possible Causes

Disks are faulty.

Procedure

Collect related information and contact technical support engineers.

----End

OceanStor 5300 V3&5500 V3&5600 V3&5800 V3&6800V3 Storage SystemEvent Reference 2 Troubleshooting Events

Issue 04 (2015-06-10) Huawei Proprietary and ConfidentialCopyright © Huawei Technologies Co., Ltd.

98

Related Information

None

2.106 0xF00B0002 LUN Has A Medium Error

Description

A medium error occurs on a LUN in the storage pool, causing possible data loss.

Attribute

ID Event Level Automatically Cleared

0xF00B0002 Critical Yes

Impact on the System

The reliability of data stored on the LUN deteriorates.

Possible Causes

Bad sectors are detected on disks.

Procedure

Step 1 Check whether the LUN has a backup.

1. If yes, restore data on the LUN from the backup LUN.

2. If no=>Step 2.

Step 2 Collect related information and contact technical support engineers.

----End

Related Information

None

2.107 0x100F000B0016 Switchover Failure Occurs On TheOwning Controller Of A LUN

Description

A switchover failure occurs on the owning controller of a LUN.

OceanStor 5300 V3&5500 V3&5600 V3&5800 V3&6800V3 Storage SystemEvent Reference 2 Troubleshooting Events

Issue 04 (2015-06-10) Huawei Proprietary and ConfidentialCopyright © Huawei Technologies Co., Ltd.

99

AttributeID Event Level Automatically Cleared

0x100F000B0016 Warning Yes

Impact on the SystemN/A.

Possible CausesN/A.

Procedure

Collect related information and contact technical support engineers.

----End

Related InformationNone

2.108 0xF00B003D Snapshot LUN Is Faulty

DescriptionA snapshot LUN is faulty, causing snapshot unavailability or snapshot data loss.

AttributeID Event Level Automatically Cleared

0xF00B003D Critical Yes

Impact on the SystemThe snapshot becomes unavailable or snapshot data is lost.

Possible CausesSnapshot LUNs are faulty.

Procedure

OceanStor 5300 V3&5500 V3&5600 V3&5800 V3&6800V3 Storage SystemEvent Reference 2 Troubleshooting Events

Issue 04 (2015-06-10) Huawei Proprietary and ConfidentialCopyright © Huawei Technologies Co., Ltd.

100

Collect related information and contact technical support engineers.

----End

Related Information

None

2.109 0xF000B0050 LUN Has A Medium Error

Description

A medium error occurs on a LUN in the storage pool, causing possible data loss and LUN nolonger available to the host.

Attribute

ID Event Level Automatically Cleared

0xF000B0050 Critical No

Impact on the System

The reliability of data stored on the LUN deteriorates and LUN will be no longer available tothe host.

Possible Causes

Bad sectors are detected on disks.

Procedure

Collect related information and contact technical support engineers.

----End

Related Information

None

2.110 0xF000B0051 LUN Has A Medium Error

Description

A medium error occurs on a LUN in the storage pool, causing possible data loss.

OceanStor 5300 V3&5500 V3&5600 V3&5800 V3&6800V3 Storage SystemEvent Reference 2 Troubleshooting Events

Issue 04 (2015-06-10) Huawei Proprietary and ConfidentialCopyright © Huawei Technologies Co., Ltd.

101

Attribute

ID Event Level Automatically Cleared

0xF000B0051 Warning No

Impact on the System

The reliability of data stored on the LUN deteriorates.

Possible Causes

Bad sectors are detected on disks.

Procedure

Collect related information and contact technical support engineers.

----End

Related Information

None

2.111 0xF0DB0002 Full LUN Copy Is Faulty

Description

A full LUN copy is faulty due to a source LUN or target LUN fault, or link down between storagedevices.

Attribute

ID Event Level Automatically Cleared

0xF0DB0002 Critical Yes

Impact on the System

Except deleting the LUN copy and deleting the target LUN, other operations related to the LUNcopy cannot be performed.

Possible Causes

l Links for LUN copy between storage arrays are unavailable.

OceanStor 5300 V3&5500 V3&5600 V3&5800 V3&6800V3 Storage SystemEvent Reference 2 Troubleshooting Events

Issue 04 (2015-06-10) Huawei Proprietary and ConfidentialCopyright © Huawei Technologies Co., Ltd.

102

l The source LUN or target LUNs are abnormal.

l The external source LUN or target LUNs are in the sleep state and will be automaticallywaked up later.

Procedure

Step 1 Check whether the links between storage arrays are down.

1. If yes, replace the faulty optical fibers or network cables. If the alarm persists=>Step 2.

2. If no=>Step 2.

Step 2 Collect related information and contact technical support engineers.

----End

Related Information

None

2.112 0xF0DC0001 Clone Pair Is Abnormally Interrupted

Description

A clone pair is abnormally interrupted.

Attribute

ID Event Level Automatically Cleared

0xF0DC0001 Critical Yes

Impact on the System

Data cannot be written onto or read from the primary or secondary LUN of the clone.

Possible Causes

l The storage pool is faulty.

l The primary LUN of a clone is faulty.

l The secondary LUN of a clone is faulty.

Procedure

Step 1 Check whether alarms are generated for the storage pools that house the primary and secondaryLUNs.

1. If yes, handle alarms with recommended actions. If the alarm clone pair is abnormallyinterrupted persists=>Step 2.

OceanStor 5300 V3&5500 V3&5600 V3&5800 V3&6800V3 Storage SystemEvent Reference 2 Troubleshooting Events

Issue 04 (2015-06-10) Huawei Proprietary and ConfidentialCopyright © Huawei Technologies Co., Ltd.

103

2. If no=>Step 2.

Step 2 Collect related information and contact technical support engineers.

----End

Related Information

None

2.113 0xF0DC0002 Clone Is Unavailable

Description

A clone is unavailable.

Attribute

ID Event Level Automatically Cleared

0xF0DC0002 Critical Yes

Impact on the System

Except deleting the secondary LUN from the clone and deleting the clone, other operationsrelated to the clone cannot be performed.

Possible Causes

Configurations of the clone are abnormal.

Procedure

Collect related information and contact technical support engineers.

----End

Related Information

None

2.114 0xF0DC0003 Clone Pair Is Unavailable

Description

A clone pair is unavailable.

OceanStor 5300 V3&5500 V3&5600 V3&5800 V3&6800V3 Storage SystemEvent Reference 2 Troubleshooting Events

Issue 04 (2015-06-10) Huawei Proprietary and ConfidentialCopyright © Huawei Technologies Co., Ltd.

104

Attribute

ID Event Level Automatically Cleared

0xF0DC0003 Critical Yes

Impact on the SystemThe clone pair is unavailable.

Possible CausesConfigurations of the clone are abnormal.

Procedure

Collect related information and contact technical support engineers.

----End

Related InformationNone

2.115 0x100F01C0003 Data On The Primary LUN In TheRemote Replication Fails To Be Rolled Back

DescriptionData on the primary LUN in the remote replication fails to be rolled back.

Attribute

ID Event Level Automatically Cleared

0x100F01C0003 Critical Yes

Impact on the SystemN/A.

Possible Causesl The storage pool is abnormal.l The primary LUN in the remote replication is faulty or has a medium error.

OceanStor 5300 V3&5500 V3&5600 V3&5800 V3&6800V3 Storage SystemEvent Reference 2 Troubleshooting Events

Issue 04 (2015-06-10) Huawei Proprietary and ConfidentialCopyright © Huawei Technologies Co., Ltd.

105

Procedure

Step 1 Check whether the storage pool is abnormal.1. if yes, please resolve problems. If the alarm persists, =>Step 2.2. if no, =>Step 2.

Step 2 Collect related information and contact technical support engineers.

----End

Related Information

None

2.116 0xF00270038 Remote Replication Is Interrupted

Description

Remote replication is interrupted.

Attribute

ID Event Level Automatically Cleared

0xF00270038 Critical Yes

Impact on the System

Except deleting the secondary LUN from the remote replication and deleting the remotereplication, other operations related to the remote replication cannot be performed.

Possible Causes

l Links are down.l Links are unstable.l Storage pools are faulty.l The service load on the remote replication devices is heavy.l The primary LUN of the remote replication is faulty.l The secondary LUN of the remote replication is faulty.

Procedure

Step 1 Check whether alarms are generated indicating link down.1. If yes, handle alarms with recommended actions. If alarm Remote Replication Is Interrupted

persists=>Step 2.2. If no=>Step 2.

OceanStor 5300 V3&5500 V3&5600 V3&5800 V3&6800V3 Storage SystemEvent Reference 2 Troubleshooting Events

Issue 04 (2015-06-10) Huawei Proprietary and ConfidentialCopyright © Huawei Technologies Co., Ltd.

106

Step 2 Check whether cables are correctly connected.1. If yes=>Step 3.2. If no, replace faulty optical fibers or network cables to ensure that all links work correctly.

If alarm Remote Replication Is Interrupted persists=>Step 3.

Step 3 Check whether alarms are generated for the storage pools that house the primary and secondaryLUNs.1. If yes, handle alarms with recommended actions. If alarm Remote Replication Is Interrupted

persists=>Step 4.2. If no=>Step 4.

Step 4 Collect related information and contact technical support engineers.

----End

Related InformationNone

2.117 0xF00270039 Remote Replication Is Unavailable

DescriptionThe properties of the local and remote storage devices of remote replication are inconsistent,causing remote replication to be unavailable.

Attribute

ID Event Level Automatically Cleared

0xF00270039 Major Yes

Impact on the SystemData cannot be backed up correctly.

Possible Causesl Remote replication is deleted on the local end after being interrupted.l When an asynchronous remote replication session is setting the secondary LUN to writable,

the secondary LUN rollback failed.

Procedure

Collect related information and contact technical support engineers.

----End

OceanStor 5300 V3&5500 V3&5600 V3&5800 V3&6800V3 Storage SystemEvent Reference 2 Troubleshooting Events

Issue 04 (2015-06-10) Huawei Proprietary and ConfidentialCopyright © Huawei Technologies Co., Ltd.

107

Related InformationNone

2.118 0xF0027003A Remote Replication Failed ToSynchronize Data Automatically

DescriptionRemote replication failed to synchronize data automatically.

Attribute

ID Event Level Automatically Cleared

0xF0027003A Major No

Impact on the SystemN/A.

Possible Causesl Storage pool capacity is used up.l Network connectivity is abnormal.

Procedure

Step 1 Check whether alarms are generated indicating storage system faults.1. If yes, handle alarms with recommended actions. If alarm Remote Replication Failed to

Synchronize Data Automatically persists=>Step 2.2. If no, synchronize data manually. If alarm Remote Replication Failed to Synchronize Data

Automatically persists=>Step 2.

Step 2 Collect related information and contact technical support engineers.

----End

Related InformationNone

OceanStor 5300 V3&5500 V3&5600 V3&5800 V3&6800V3 Storage SystemEvent Reference 2 Troubleshooting Events

Issue 04 (2015-06-10) Huawei Proprietary and ConfidentialCopyright © Huawei Technologies Co., Ltd.

108

2.119 0x100F0027008B Failed To Roll Back The SecondaryLUN In Remote Replication

Description

Failed to roll back the secondary lUN in remote replication.

Attribute

ID Event Level Automatically Cleared

0x100F0027008B Critical Yes

Impact on the System

N/A.

Possible Causes

l The secondary LUN is faulty.

l Storage pools are faulty.

Procedure

Step 1 Check whether alarms are generated for the storage pool that houses the secondary LUN.

1. If yes, handle alarms with recommended actions. If alarm Failed to Roll Back the SecondaryLUN in a Remote Replication persist=>Step 2.

2. If no=>Step 2.

Step 2 Collect related information and contact technical support engineers.

----End

Related Information

None

2.120 0xF0DD0001 Remote Replication Consistency GroupIs Disconnected

Description

Remote replication consistency group is disconnected abnormally.

OceanStor 5300 V3&5500 V3&5600 V3&5800 V3&6800V3 Storage SystemEvent Reference 2 Troubleshooting Events

Issue 04 (2015-06-10) Huawei Proprietary and ConfidentialCopyright © Huawei Technologies Co., Ltd.

109

Attribute

ID Event Level Automatically Cleared

0xF0DD0001 Critical Yes

Impact on the System

A consistency group disconnected due to storage array link down is available only after the linksare back to normal. If the links are down permanently, the consistency group must be deleted.

Possible Causes

l Links are down.

l Links are unstable.

l Storage pools are faulty.

l The service load on the remote replication destination is heavy.

l The primary LUN of the remote replication is faulty.

l The secondary LUN of the remote replication is faulty.

Procedure

Step 1 Check whether alarms are generated indicating link down.

1. If yes, handle alarms with recommended actions. If alarm Remote Replication ConsistencyGroup Is Disconnected persists=>Step 2.

2. If no=>Step 2.

Step 2 Check whether cables are correctly connected.

1. If yes=>Step 3.

2. If no, replace faulty optical fibers or network cables to ensure that all links work correctly.If alarm Remote Replication Consistency Group Is Disconnected persists=>Step 3.

Step 3 Check whether alarms are generated for the storage pools that house the primary and secondaryLUNs.

1. If yes, handle alarms with recommended actions. If alarm Remote Replication ConsistencyGroup Is Disconnected persists=>Step 4.

2. If no=>Step 4.

Step 4 Collect related information and contact technical support engineers.

----End

Related Information

None

OceanStor 5300 V3&5500 V3&5600 V3&5800 V3&6800V3 Storage SystemEvent Reference 2 Troubleshooting Events

Issue 04 (2015-06-10) Huawei Proprietary and ConfidentialCopyright © Huawei Technologies Co., Ltd.

110

2.121 0xF0DD0002 Remote Replication Consistency GroupIs Unavailable

Description

A remote replication consistency group is unavailable.

Attribute

ID Event Level Automatically Cleared

0xF0DD0002 Major Yes

Impact on the System

N/A.

Possible Causes

l After the consistency group is disconnected, primary/secondary switchover is forciblyperformed.

l The consistency group is deleted after being disconnected.

l The consistency group contains unavailable remote replication.

Procedure

Collect related information and contact technical support engineers.

----End

Related Information

None

2.122 0xF01C0005 Remote Replication Consistency GroupFailed To Synchronize Data Automatically

Description

A remote replication consistency group failed to synchronize data automatically.

OceanStor 5300 V3&5500 V3&5600 V3&5800 V3&6800V3 Storage SystemEvent Reference 2 Troubleshooting Events

Issue 04 (2015-06-10) Huawei Proprietary and ConfidentialCopyright © Huawei Technologies Co., Ltd.

111

Attribute

ID Event Level Automatically Cleared

0xF01C0005 Major No

Impact on the System

N/A.

Possible Causes

l Storage pool capacity is used up.

l Network connectivity is abnormal.

Procedure

Step 1 Check whether alarms are generated indicating storage system faults.

1. If yes, handle alarms with recommended actions. If alarm Remote Replication ConsistencyGroup Failed to Synchronize Data Automatically persists=>Step 2.

2. If no, synchronize data manually. If alarm Remote Replication Consistency Group Failedto Synchronize Data Automatically persists=>Step 2.

Step 2 Collect related information and contact technical support engineers.

----End

Related Information

None

2.123 0x100F01B0001 Snapshot Rollback StoppedUnexpectedly

Description

Snapshot rollback stopped unexpectedly.

Attribute

ID Event Level Automatically Cleared

0x100F01B0001 Warning Yes

OceanStor 5300 V3&5500 V3&5600 V3&5800 V3&6800V3 Storage SystemEvent Reference 2 Troubleshooting Events

Issue 04 (2015-06-10) Huawei Proprietary and ConfidentialCopyright © Huawei Technologies Co., Ltd.

112

Impact on the System

Data on the source LUN may be inconsistent.

Possible Causes

l The snapshot failed.

l The source LUN is faulty.

Procedure

Step 1 Check whether the snapshot is in the normal state.

1. If yes, roll back the snapshot manually. If the rollback fails=>Step 2.

2. If no=>Step 2.

Step 2 Collect related information and contact technical support engineers.

----End

Related Information

None

2.124 0xE02050002 Snapshot Unavailable

Description

Storage pool space is used up or the source LUN is faulty, causing snapshots to be unavailable.

Attribute

ID Event Level Automatically Cleared

0xE02050002 Major Yes

Impact on the System

The snapshot becomes unavailable or snapshot data is lost.

Possible Causes

The remaining capacity of storage pools is insufficient.

Procedure

Step 1 Check whether alarms are generated indicating insufficient storage pool capacity.

1. If yes, add disks to storage pools and activate the snapshot.

OceanStor 5300 V3&5500 V3&5600 V3&5800 V3&6800V3 Storage SystemEvent Reference 2 Troubleshooting Events

Issue 04 (2015-06-10) Huawei Proprietary and ConfidentialCopyright © Huawei Technologies Co., Ltd.

113

2. If no=>Step 2.

Step 2 Collect related information and contact technical support engineers.

----End

Related InformationNone

2.125 0x200F001B0046 Succeeded In Canceling SnapshotRollback

DescriptionSucceeded in canceling snapshot rollback.

Attribute

ID Event Level Automatically Cleared

0x200F001B0046 Major Yes

Impact on the SystemData on the source LUN may be inconsistent.

Possible CausesN/A.

Procedure

Collect related information and contact technical support engineers.

----End

Related InformationNone

2.126 0x200F001B0047 Failed To Cancel Snapshot Rollback

DescriptionCanceling snapshot rollback failed.

OceanStor 5300 V3&5500 V3&5600 V3&5800 V3&6800V3 Storage SystemEvent Reference 2 Troubleshooting Events

Issue 04 (2015-06-10) Huawei Proprietary and ConfidentialCopyright © Huawei Technologies Co., Ltd.

114

Attribute

ID Event Level Automatically Cleared

0x200F001B0047 Major Yes

Impact on the System

Data on the source LUN may be inconsistent.

Possible Causes

l The snapshot failed.

l The source LUN is faulty.

Procedure

Step 1 Check whether the snapshot is in the normal state.

1. If yes, roll back the snapshot manually. If the rollback fails=>Step 2.

2. If no=>Step 2.

Step 2 Collect related information and contact technical support engineers.

----End

Related Information

None

2.127 0xF0E10001 Replication Link Is Down

Description

The replication link between a local and remote storage arrays is down, causing the failure toaccess the remote storage array.

Attribute

ID Event Level Automatically Cleared

0xF0E10001 Major Yes

Impact on the System

l If a local storage array is redundantly connected to a remote storage array, one link downwill compromise storage system performance and reliability.

OceanStor 5300 V3&5500 V3&5600 V3&5800 V3&6800V3 Storage SystemEvent Reference 2 Troubleshooting Events

Issue 04 (2015-06-10) Huawei Proprietary and ConfidentialCopyright © Huawei Technologies Co., Ltd.

115

l If a local storage array is connected to a remote storage array through only one link, thelink down will interrupt the LUN copy between storage arrays or between the primary andsecondary LUNs of remote replication.

Possible Causes

l The replication link is down.

l Remote storage arrays are faulty or restarting.

l Local storage arrays are faulty.

Procedure

Step 1 Check all cable connections.1. If any cable is removed, reinsert it. If the alarm persists=>Step 1.2.2. Replace the cable. If the alarm persists=>Step 2.3. If all cable connections are normal=>Step 2.

Step 2 Check all remote storage arrays.1. If any remote storage array is faulty, handle the fault with recommended actions. If the

alarm persists=>Step 2.2.2. If any remote storage array is restarting, wait until the restart completes. If the alarm

persists=>Step 3.3. If all remote storage arrays are working correctly=>Step 3.

Step 3 Check all local storage arrays.1. If any local storage array is faulty, handle the fault with recommended actions. If the alarm

persists=>Step 4.2. If all local storage arrays are working correctly=>Step 4.

Step 4 Collect related information and contact technical support engineers.

----End

Related Information

None

2.128 0xF00E00014 No Backup Links Available

Description

No backup links available.

Attribute

ID Event Level Automatically Cleared

0xF00E00014 Warning Yes

OceanStor 5300 V3&5500 V3&5600 V3&5800 V3&6800V3 Storage SystemEvent Reference 2 Troubleshooting Events

Issue 04 (2015-06-10) Huawei Proprietary and ConfidentialCopyright © Huawei Technologies Co., Ltd.

116

Impact on the System

N/A.

Possible Causes

No backup links are configured for the remote device.

Procedure

Step 1 Configure backup links for the remote device. If the alarm persists=>Step 2.

Step 2 Collect related information and contact technical support engineers.

----End

Related Information

None

2.129 0xF0C90004 CPU Usage Is Too High

Description

The CPU usage of the controller exceeds the threshold.

Attribute

ID Event Level Automatically Cleared

0xF0C90004 Warning Yes

Impact on the System

The performance of the storage system deteriorates.

Possible Causes

The service load is too heavy.

Procedure

Collect related information and contact technical support engineers.

----End

OceanStor 5300 V3&5500 V3&5600 V3&5800 V3&6800V3 Storage SystemEvent Reference 2 Troubleshooting Events

Issue 04 (2015-06-10) Huawei Proprietary and ConfidentialCopyright © Huawei Technologies Co., Ltd.

117

Related InformationNone

2.130 0xF0C90005 Memory Usage Is Too High

DescriptionThe memory utilization rate threshold has been reached.

Attribute

ID Event Level Automatically Cleared

0xF0C90005 Warning Yes

Impact on the SystemThe performance of the storage system deteriorates.

Possible CausesThe service load is too heavy.

Procedure

Collect related information and contact technical support engineers.

----End

Related InformationNone

2.131 0xF00CF002F Inconsistent Memory CapacitiesBetween Controllers

DescriptionMemory capacities of two controllers are inconsistent.

OceanStor 5300 V3&5500 V3&5600 V3&5800 V3&6800V3 Storage SystemEvent Reference 2 Troubleshooting Events

Issue 04 (2015-06-10) Huawei Proprietary and ConfidentialCopyright © Huawei Technologies Co., Ltd.

118

Attribute

ID Event Level Automatically Cleared

0xF00CF002F Major Yes

Impact on the SystemThe controllers may not restart correctly.

Possible CausesMemory capacities of controllers are inconsistent.

Procedure

Collect related information and contact technical support engineers.

----End

Related InformationNone

2.132 0xF010C0014 Number Of Initiators Connected To APort Exceeds The System Limit

DescriptionThe number of initiators connected to a port exceeds the system limit, causing some initiatorsto fail to be connected.

Attribute

ID Event Level Automatically Cleared

0xF010C0014 Major Yes

Impact on the SystemSome initiators fail to be connected.

Possible CausesThe number of initiators exceeds the system limit.

OceanStor 5300 V3&5500 V3&5600 V3&5800 V3&6800V3 Storage SystemEvent Reference 2 Troubleshooting Events

Issue 04 (2015-06-10) Huawei Proprietary and ConfidentialCopyright © Huawei Technologies Co., Ltd.

119

Procedure

Step 1 Adjust the service network and ensure that the number of initiators connected to each port meetrequirements. If the alarm persists=>Step 2.

Step 2 Collect related information and contact technical support engineers.

----End

Related Information

None

2.133 0x100F010C0015 iSCSI Initiator Login Failed

Description

The initiator login failed.

Attribute

ID Event Level Automatically Cleared

0x100F010C0015 Major Yes

Impact on the System

N/A.

Possible Causes

CHAP user name and password are incorrect.

Procedure

Step 1 Use correct CHAP user name and password for login. If the alarm persists=>Step 2.

Step 2 Collect related information and contact technical support engineers.

----End

Related Information

None

OceanStor 5300 V3&5500 V3&5600 V3&5800 V3&6800V3 Storage SystemEvent Reference 2 Troubleshooting Events

Issue 04 (2015-06-10) Huawei Proprietary and ConfidentialCopyright © Huawei Technologies Co., Ltd.

120

2.134 0x100F010C0030 Number Of Initiators Connected ToA Port Exceeds The System Limit

Description

The number of initiators connected to a port exceeds the system limit.

Attribute

ID Event Level Automatically Cleared

0x100F010C0030 Major Yes

Impact on the System

Hosts access to storage arrays fail.

Possible Causes

The number of initiators connected to a port exceeds the system limit.

Procedure

Step 1 Delete initiators whose state is offline. If the alarm persists=>Step 2.

Step 2 Collect related information and contact technical support engineers.

----End

Related Information

None

2.135 0x100F010C0031 Initiator IP Address Is Changed

Description

The IP address of an initiator is changed.

Attribute

ID Event Level Automatically Cleared

0x100F010C0031 Major Yes

OceanStor 5300 V3&5500 V3&5600 V3&5800 V3&6800V3 Storage SystemEvent Reference 2 Troubleshooting Events

Issue 04 (2015-06-10) Huawei Proprietary and ConfidentialCopyright © Huawei Technologies Co., Ltd.

121

Impact on the SystemN/A.

Possible Causesl The host corresponding to the initiator is connected to the storage system through different

IP addresses.l The initiator is used by different hosts to connect to the storage system.

Procedure

Step 1 Check whether the two different IP addresses are used by the same host.1. If yes, ignore this alarm.2. If no=>Step 2.

Step 2 Check whether the same initiator ID is used by two hosts to connect to the storage system.1. If yes, change the initiator ID of either host and ensure that the two initiator IDs are different.2. If no=>Step 3.

Step 3 Collect related information and contact technical support engineers.

----End

Related InformationNone

2.136 0xF010D0027 BBU Firmware Is Incompatible WithStorage Array Software

DescriptionThe firmware version of a BBU module is incompatible with storage array software.

AttributeID Event Level Automatically Cleared

0xF010D0027 Warning Yes

Impact on the SystemThe normal operation of the BBU module is not adversely affected.

Possible CausesThe firmware version of a BBU module is incompatible with storage array software.

OceanStor 5300 V3&5500 V3&5600 V3&5800 V3&6800V3 Storage SystemEvent Reference 2 Troubleshooting Events

Issue 04 (2015-06-10) Huawei Proprietary and ConfidentialCopyright © Huawei Technologies Co., Ltd.

122

Procedure

Collect related information and contact technical support engineers.

----End

Related Information

None

2.137 0xF010D0028 Interface Module Firmware IsIncompatible With Storage Array Software

Description

The firmware version of an interface module is incompatible with storage array software.

Attribute

ID Event Level Automatically Cleared

0xF010D0028 Major Yes

Impact on the System

The interface module fails to function.

Possible Causes

The firmware version of the interface module is incompatible with storage array software.

Procedure

Collect related information and contact technical support engineers.

----End

Related Information

None

OceanStor 5300 V3&5500 V3&5600 V3&5800 V3&6800V3 Storage SystemEvent Reference 2 Troubleshooting Events

Issue 04 (2015-06-10) Huawei Proprietary and ConfidentialCopyright © Huawei Technologies Co., Ltd.

123

2.138 0xF010D0029 Expansion Module Firmware IsIncompatible With Storage Array Software

Description

The firmware version of an expansion module is incompatible with storage array software.

Attribute

ID Event Level Automatically Cleared

0xF010D0029 Major Yes

Impact on the System

Ports on the expansion module are isolated.

Possible Causes

The firmware version of the expansion module is incompatible with storage array software.

Procedure

Collect related information and contact technical support engineers.

----End

Related Information

None

2.139 0x200F010D0018 Failed To Delete A Hot Patch

Description

Failed to delete a hot patch.

Attribute

ID Event Level Automatically Cleared

0x200F010D0018 Warning Yes

OceanStor 5300 V3&5500 V3&5600 V3&5800 V3&6800V3 Storage SystemEvent Reference 2 Troubleshooting Events

Issue 04 (2015-06-10) Huawei Proprietary and ConfidentialCopyright © Huawei Technologies Co., Ltd.

124

Impact on the SystemN/A.

Possible CausesN/A.

Procedure

Collect related information and contact technical support engineers.

----End

Related InformationNone

2.140 0x200F010D001B Failed To Start An Upgrade

DescriptionFailed to start an upgrade.

Attribute

ID Event Level Automatically Cleared

0x200F010D001B Warning Yes

Impact on the SystemN/A.

Possible CausesN/A.

Procedure

Collect related information and contact technical support engineers.

----End

Related InformationNone

OceanStor 5300 V3&5500 V3&5600 V3&5800 V3&6800V3 Storage SystemEvent Reference 2 Troubleshooting Events

Issue 04 (2015-06-10) Huawei Proprietary and ConfidentialCopyright © Huawei Technologies Co., Ltd.

125

2.141 0x200F010D001E Failed To Start The Upgrade Of DiskFirmware

DescriptionIt is failed to start the upgrade of disk firmware.

AttributeID Event Level Automatically Cleared

0x200F010D001E Warning No

Impact on the SystemN/A.

Possible CausesN/A.

Procedure

Collect related information and contact technical support engineers.

----End

Related InformationNone

2.142 0x200F010D0021 Failed To Start The Upgrade Of DiskConverter Firmware

DescriptionFailed to start the upgrade of disk converter firmware

AttributeID Event Level Automatically Cleared

0x200F010D0021 Warning Yes

OceanStor 5300 V3&5500 V3&5600 V3&5800 V3&6800V3 Storage SystemEvent Reference 2 Troubleshooting Events

Issue 04 (2015-06-10) Huawei Proprietary and ConfidentialCopyright © Huawei Technologies Co., Ltd.

126

Impact on the SystemN/A.

Possible CausesN/A.

Procedure

Collect related information and contact technical support engineers.

----End

Related InformationNone

2.143 0x200F010D0024 Failed To Start Rollback

DescriptionFailed to start a rollback.

Attribute

ID Event Level Automatically Cleared

0x200F010D0024 Warning Yes

Impact on the SystemN/A.

Possible CausesN/A.

Procedure

Collect related information and contact technical support engineers.

----End

Related InformationNone

OceanStor 5300 V3&5500 V3&5600 V3&5800 V3&6800V3 Storage SystemEvent Reference 2 Troubleshooting Events

Issue 04 (2015-06-10) Huawei Proprietary and ConfidentialCopyright © Huawei Technologies Co., Ltd.

127

2.144 0x100F010D0026 Rollback Failed

Description

Rollback failed.

Attribute

ID Event Level Automatically Cleared

0x100F010D0026 Warning Yes

Impact on the System

N/A.

Possible Causes

N/A.

Procedure

Collect related information and contact technical support engineers.

----End

Related Information

None

2.145 0x100F010D0027 Upgrade Failed

Description

Upgrade failed.

Attribute

ID Event Level Automatically Cleared

0x100F010D0027 Warning Yes

OceanStor 5300 V3&5500 V3&5600 V3&5800 V3&6800V3 Storage SystemEvent Reference 2 Troubleshooting Events

Issue 04 (2015-06-10) Huawei Proprietary and ConfidentialCopyright © Huawei Technologies Co., Ltd.

128

Impact on the SystemN/A.

Possible CausesN/A.

Procedure

Collect related information and contact technical support engineers.

----End

Related InformationNone

2.146 0xF00150019 Host Is Not Redundantly Connected ToStorage Arrays

DescriptionA host is not redundantly connected to storage arrays.

Attribute

ID Event Level Automatically Cleared

0xF00150019 Major Yes

Impact on the SystemN/A.

Possible Causesl The host is not redundantly connected to storage array controllers.l LUN mappings incorrectly added.l Disk scan is not performed on the host after LUN mappings are added, causing the failure

to discover some or all disks.

Procedure

Step 1 Check whether the host is connected only to one controller.1. If yes, connect the host to multiple controllers. If the alarm persists=>Step 2.

OceanStor 5300 V3&5500 V3&5600 V3&5800 V3&6800V3 Storage SystemEvent Reference 2 Troubleshooting Events

Issue 04 (2015-06-10) Huawei Proprietary and ConfidentialCopyright © Huawei Technologies Co., Ltd.

129

2. If no=>Step 2.

Step 2 Check whether initiators configured for the host are consistent with the actual condition.

1. If yes=>Step 3.

2. If no, add all initiators to the host based on the actual condition. If the alarm persists=>Step3.

Step 3 Scan for disks on the host and confirm that the number of detected disks is correct. If the alarmpersists=>Step 4.

Step 4 Collect related information and contact technical support engineers.

----End

Related Information

None

2.147 0xF0015001A Link Between A Host And Storage ArrayIs Down

Description

The link between a host and storage array is down.

Attribute

ID Event Level Automatically Cleared

0xF0015001A Major Yes

Impact on the System

N/A.

Possible Causes

l Cables between the host and the storage array are removed or damaged.

l Optical modules are faulty.

l The host port is faulty.

l Interface modules are faulty.

l Controllers are faulty.

l The host HBA is faulty.

l Switches are faulty.

OceanStor 5300 V3&5500 V3&5600 V3&5800 V3&6800V3 Storage SystemEvent Reference 2 Troubleshooting Events

Issue 04 (2015-06-10) Huawei Proprietary and ConfidentialCopyright © Huawei Technologies Co., Ltd.

130

Procedure

Step 1 Check the cables connected between the host and the storage array.

1. If any cable is removed, reinsert it. If the alarm persists=>Step 1.2.

2. Replace the cable. If the alarm persists=>Step 2.

Step 2 Check whether alarms are generated indicating optical module faults.

1. If yes, handle the alarms by taking recommended actions. If the alarm persists=>Step 3.

2. If no=>Step 3.

Step 3 Check whether alarms are generated indicating port faults.

1. If yes, handle the alarms by taking recommended actions. If the alarm persists=>Step 4.

2. If no=>Step 4.

Step 4 Check whether alarms are generated indicating interface module faults.

1. If yes, handle the alarms by taking recommended actions. If the alarm persists=>Step 5.

2. If no=>Step 5.

Step 5 Check whether alarms are generated indicating controller faults.

1. If yes, handle the alarms by taking recommended actions. If the alarm persists=>Step 6.

2. If no=>Step 6.

Step 6 Check the HBAs on the host. Contact the HBA provider for help when necessary.

Step 7 Check related switches. Contact the switch provider for help when necessary.

Step 8 Collect related information and contact technical support engineers.

----End

Related Information

None

2.148 0xF0015001B Link Between A Host And Storage ArrayIs Unstable

Description

A link between a host and storage array is unstable.

Attribute

ID Event Level Automatically Cleared

0xF0015001B Major Yes

OceanStor 5300 V3&5500 V3&5600 V3&5800 V3&6800V3 Storage SystemEvent Reference 2 Troubleshooting Events

Issue 04 (2015-06-10) Huawei Proprietary and ConfidentialCopyright © Huawei Technologies Co., Ltd.

131

Impact on the System

N/A.

Possible Causes

l Cables between the host and the storage array are loose or damaged.

l Optical modules are faulty.

l The host port is faulty.

l The host HBA is faulty.

l Switches are faulty.

Procedure

Step 1 Check the cables connected between the host and the storage array.

1. If any cable is loose, reinsert it. If the alarm persists=>Step 1.2.

2. Replace the cable. If the alarm persists=>Step 2.

Step 2 Check whether alarms are generated indicating optical module faults.

1. If yes, handle the alarms by taking recommended actions. If the alarm persists=>Step 3.

2. If no=>Step 3.

Step 3 Check whether alarms are generated indicating port faults.

1. If yes, handle the alarms by taking recommended actions. If the alarm persists=>Step 4.

2. If no=>Step 4.

Step 4 Check the HBAs on the host. Contact the HBA provider for help when necessary.

Step 5 Check related switches. Contact the switch provider for help when necessary.

Step 6 Collect related information and contact technical support engineers.

----End

Related Information

None

2.149 0x100F0015001C Ultrapath Is Not Installed OrUltrapath Version Outdated

Description

UltraPath is not installed or the version of UltraPath is outdated.

OceanStor 5300 V3&5500 V3&5600 V3&5800 V3&6800V3 Storage SystemEvent Reference 2 Troubleshooting Events

Issue 04 (2015-06-10) Huawei Proprietary and ConfidentialCopyright © Huawei Technologies Co., Ltd.

132

Attribute

ID Event Level Automatically Cleared

0x100F0015001C Major Yes

Impact on the System

N/A.

Possible Causes

l UltraPath is not installed on the host.

l The version of the installed UltraPath is outdated.

Procedure

Step 1 Install UltraPath of the latest version on the host. If the alarm persists=>Step 2.

Step 2 Collect related information and contact technical support engineers.

----End

Related Information

None

2.150 0xF0015001D Ultrapath Incompatible With StorageArray Software

Description

UltraPath on the host is incompatible with disk array software.

Attribute

ID Event Level Automatically Cleared

0xF0015001D Major Yes

Impact on the System

N/A.

OceanStor 5300 V3&5500 V3&5600 V3&5800 V3&6800V3 Storage SystemEvent Reference 2 Troubleshooting Events

Issue 04 (2015-06-10) Huawei Proprietary and ConfidentialCopyright © Huawei Technologies Co., Ltd.

133

Possible Causes

l The UltraPath version is outdated.

l The storage array software version is outdated.

Procedure

Step 1 Upgrade storage array software or UltraPath to a compatible version. If the alarmpersists=>Step 2.

Step 2 Collect related information and contact technical support engineers.

----End

Related Information

None

2.151 0x100F00150036 Data Sent To A Storage Array Port ByThe Host Failed To Be Verified

Description

Data sent to a storage array port by the host failed to be verified.

Attribute

ID Event Level Automatically Cleared

0x100F00150036 Major Yes

Impact on the System

Data write may fail.

Possible Causes

l The host is faulty.

l The port is faulty or the link between the host and the port is down.

Procedure

Collect related information and contact technical support engineers.

----End

OceanStor 5300 V3&5500 V3&5600 V3&5800 V3&6800V3 Storage SystemEvent Reference 2 Troubleshooting Events

Issue 04 (2015-06-10) Huawei Proprietary and ConfidentialCopyright © Huawei Technologies Co., Ltd.

134

Related Information

None

2.152 0xF00310004 The Space That Stores Event Logs Is ToBe Used Up

Description

The space that stores event logs is to be used up.

Attribute

ID Event Level Automatically Cleared

0xF00310004 Warning Yes

Impact on the System

After the number of events reaches the upper limit, earlier events are deleted.

Possible Causes

N/A.

Procedure

Step 1 Configure the event log dumping server and open the dumping switch. After the dumpingfinished, if the alarm persists=>Step 2.

Step 2 Collect related information and contact technical support engineers.

----End

Related Information

None

2.153 0xD80001 Storage Pool Remaining Capacity IsInsufficient

Description

The used capacity of a storage pool reachs the threshold.

OceanStor 5300 V3&5500 V3&5600 V3&5800 V3&6800V3 Storage SystemEvent Reference 2 Troubleshooting Events

Issue 04 (2015-06-10) Huawei Proprietary and ConfidentialCopyright © Huawei Technologies Co., Ltd.

135

Attribute

ID Event Level Automatically Cleared

0xD80001 Major Yes

Impact on the SystemN/A.

Possible CausesThe used capacity of the storage pool reachs the threshold.

Procedure

Step 1 Expand the capacity of the storage pool. If the alarm persists=>Step 2.

Step 2 Collect related information and contact technical support engineers.

----End

Related InformationNone

2.154 0xD80002 Storage Pool Capacity Is About To Be UsedUp

DescriptionThe storage pool capacity is about to be used up, which may cause service interruption on thispool.

Attribute

ID Event Level Automatically Cleared

0xD80002 Critical Yes

Impact on the SystemSome services on the storage pool may be interrupted.

Possible CausesThe storage pool capacity is about to be used up.

OceanStor 5300 V3&5500 V3&5600 V3&5800 V3&6800V3 Storage SystemEvent Reference 2 Troubleshooting Events

Issue 04 (2015-06-10) Huawei Proprietary and ConfidentialCopyright © Huawei Technologies Co., Ltd.

136

Procedure

Step 1 Expand the capacity of the storage pool. If the alarm persists=>Step 2.

Step 2 Collect related information and contact technical support engineers.

----End

Related Information

None

2.155 0x10A0001 Disk Domain Is Degraded

Description

A disk domain is degraded.

Attribute

ID Event Level Automatically Cleared

0x10A0001 Major Yes

Impact on the System

Storage pools using the disk domain may become faulty, causing LUNs and snapshots to fail.

Possible Causes

l Member disks are removed.

l Member disks are faulty.

Procedure

Step 1 Check whether alarms are generated indicating disk removal.

1. If yes, reinsert the removed disks. If the alarm persists=>Step 2.

2. If no=>Step 2.

Step 2 Check whether alarms are generated indicating disk faults.

1. If yes, replace the faulty disks. If the alarm persists=>Step 3.

2. If no=>Step 3.

Step 3 Collect related information and contact technical support engineers.

----End

OceanStor 5300 V3&5500 V3&5600 V3&5800 V3&6800V3 Storage SystemEvent Reference 2 Troubleshooting Events

Issue 04 (2015-06-10) Huawei Proprietary and ConfidentialCopyright © Huawei Technologies Co., Ltd.

137

Related InformationNone

2.156 0x10A0002 Disk Domain Is Faulty

DescriptionA disk domain is faulty.

Attribute

ID Event Level Automatically Cleared

0x10A0002 Critical Yes

Impact on the SystemStorage pools using the disk domain may become faulty, causing LUNs and snapshots to fail.

Possible Causesl Member disks are removed.l Member disks are faulty.

Procedure

Step 1 Check whether alarms are generated indicating disk removal.1. If yes, reinsert the removed disks.2. If no=>Step 2.

Step 2 Check whether alarms are generated indicating disk faults.1. If yes, replace the faulty disks. If the alarm persists=>Step 3.2. If no=>Step 3.

Step 3 Collect related information and contact technical support engineers.

----End

Related InformationNone

OceanStor 5300 V3&5500 V3&5600 V3&5800 V3&6800V3 Storage SystemEvent Reference 2 Troubleshooting Events

Issue 04 (2015-06-10) Huawei Proprietary and ConfidentialCopyright © Huawei Technologies Co., Ltd.

138

2.157 0x10A0003 Disk Domain Is Offline

DescriptionA disk domain is offline.

Attribute

ID Event Level Automatically Cleared

0x10A0003 Critical Yes

Impact on the SystemAll LUNs and snapshots in the disk domain go offline.

Possible Causesl Member disks are removed.l Member disks are faulty.

Procedure

Step 1 Check whether alarms are generated indicating disk removal.1. If yes, reinsert the removed disks.2. If no=>Step 2.

Step 2 Check whether alarms are generated indicating disk faults.1. If yes, replace the faulty disks. If the alarm persists=>Step 3.2. If no=>Step 3.

Step 3 Collect related information and contact technical support engineers.

----End

Related InformationNone

2.158 0x10A0005 Hot Spare Capacity Of The Disk DomainIs Insufficient

DescriptionThe host spare capacity for a disk domain is insufficient.

OceanStor 5300 V3&5500 V3&5600 V3&5800 V3&6800V3 Storage SystemEvent Reference 2 Troubleshooting Events

Issue 04 (2015-06-10) Huawei Proprietary and ConfidentialCopyright © Huawei Technologies Co., Ltd.

139

Attribute

ID Event Level Automatically Cleared

0x10A0005 Major Yes

Impact on the System

N/A.

Possible Causes

The remaining hot spare capacity is lower than the threshold.

Procedure

Step 1 Add disks to the disk domain. If the alarm persists=>Step 2.

Step 2 Collect related information and contact technical support engineers.

----End

Related Information

None

2.159 0x10A0006 Inconsistent Disk Domain Disk Types

Description

Disks in a disk domain are different in type.

Attribute

ID Event Level Automatically Cleared

0x10A0006 Major Yes

Impact on the System

The disk fails to work.

Possible Causes

The type of the newly added disk is inconsistent with that of the existing disks in the disk domain.

OceanStor 5300 V3&5500 V3&5600 V3&5800 V3&6800V3 Storage SystemEvent Reference 2 Troubleshooting Events

Issue 04 (2015-06-10) Huawei Proprietary and ConfidentialCopyright © Huawei Technologies Co., Ltd.

140

Procedure

Step 1 Replace the newly added disk with a one that meets system requirements. If the alarmpersists=>Step 2.

Step 2 Collect related information and contact technical support engineers.

----End

Related Information

None

2.160 0x10A0007 Number Of Disks In A Disk Domain DoesNot Meet Hot Spare Requirements

Description

The number of disks in a disk domain does not meet hot spare requirements.

Attribute

ID Event Level Automatically Cleared

0x10A0007 Warning Yes

Impact on the System

N/A.

Possible Causes

The number of disks in the disk domain is insufficient.

Procedure

Step 1 Add disks to the disk domain. If the alarm persists=>Step 2.

Step 2 Collect related information and contact technical support engineers.

----End

Related Information

None

OceanStor 5300 V3&5500 V3&5600 V3&5800 V3&6800V3 Storage SystemEvent Reference 2 Troubleshooting Events

Issue 04 (2015-06-10) Huawei Proprietary and ConfidentialCopyright © Huawei Technologies Co., Ltd.

141

2.161 0x10A0008 A Disk Is Removed From A Disk Domain

Description

A disk is removed from a disk domain.

Attribute

ID Event Level Automatically Cleared

0x10A0008 Major Yes

Impact on the System

N/A.

Possible Causes

A disk is removed from a disk domain.

Procedure

Step 1 Add the removed disk to the disk domain. If the alarm persists=>Step 2.

Step 2 Collect related information and contact technical support engineers.

----End

Related Information

None

2.162 0x1000010A000B The Disk Domain ReconstructionFailed

Description

Disk domain reconstruction failed.

Attribute

ID Event Level Automatically Cleared

0x1000010A000B Major Yes

OceanStor 5300 V3&5500 V3&5600 V3&5800 V3&6800V3 Storage SystemEvent Reference 2 Troubleshooting Events

Issue 04 (2015-06-10) Huawei Proprietary and ConfidentialCopyright © Huawei Technologies Co., Ltd.

142

Impact on the System

N/A.

Possible Causes

l Disk domain capacity is insufficient.

l Disks are removed.

l Disks are faulty.

Procedure

Step 1 Check whether alarms are generated indicating insufficient disk domain capacity.1. If yes, add disks to the disk domain. If the alarm persists=>Step 2.2. If no=>Step 2.

Step 2 Check whether alarms are generated indicating disk removal.1. If yes, reinsert the removed disks. If the alarm persists=>Step 3.2. If no=>Step 3.

Step 3 Check whether alarms are generated indicating disk faults.1. If yes, replace the faulty disks. If the alarm persists=>Step 4.2. If no=>Step 4.

Step 4 Collect related information and contact technical support engineers.

----End

Related Information

None

2.163 0x1000010A000E Precopy Failed

Description

The precopy of a disk domain failed.

Attribute

ID Event Level Automatically Cleared

0x1000010A000E Major Yes

Impact on the System

N/A.

OceanStor 5300 V3&5500 V3&5600 V3&5800 V3&6800V3 Storage SystemEvent Reference 2 Troubleshooting Events

Issue 04 (2015-06-10) Huawei Proprietary and ConfidentialCopyright © Huawei Technologies Co., Ltd.

143

Possible Causes

l Disk domain capacity is insufficient.

l Disks are removed.

l Disks are faulty.

Procedure

Step 1 Check whether alarms are generated indicating insufficient disk domain capacity.

1. If yes, add disks to the disk domain. If the alarm persists=>Step 2.

2. If no=>Step 2.

Step 2 Check whether alarms are generated indicating disk removal.

1. If yes, reinsert the removed disks. If the alarm persists=>Step 3.

2. If no=>Step 3.

Step 3 Collect related information and contact technical support engineers.

----End

Related Information

None

2.164 0x1000010A0011 Data Balancing Failed

Description

A disk domain failed to balance data automatically.

Attribute

ID Event Level Automatically Cleared

0x1000010A0011 Warning Yes

Impact on the System

N/A.

Possible Causes

N/A.

Procedure

OceanStor 5300 V3&5500 V3&5600 V3&5800 V3&6800V3 Storage SystemEvent Reference 2 Troubleshooting Events

Issue 04 (2015-06-10) Huawei Proprietary and ConfidentialCopyright © Huawei Technologies Co., Ltd.

144

Collect related information and contact technical support engineers.

----End

Related InformationNone

2.165 0x10A001C Disk Domain Member Disk Is InsertedInto An Incorrect Slot

DescriptionDisk domain member disk is inserted into an lncorrect slot.

AttributeID Event Level Automatically Cleared

0x10A001C Major Yes

Impact on the SystemN/A.

Possible CausesThe member disk is inserted into a slot different from where it was inserted before beingremoved.

Procedure

Step 1 Insert the disk into the slot where it resided before it was removed. If the alarm persists=>Step2.

Step 2 Collect related information and contact technical support engineers.

----End

Related InformationNone

2.166 0x10C000B Controller Write Cache Is Disabled

DescriptionController write cache is disabled.

OceanStor 5300 V3&5500 V3&5600 V3&5800 V3&6800V3 Storage SystemEvent Reference 2 Troubleshooting Events

Issue 04 (2015-06-10) Huawei Proprietary and ConfidentialCopyright © Huawei Technologies Co., Ltd.

145

Attribute

ID Event Level Automatically Cleared

0x10C000B Major Yes

Impact on the System

N/A.

Possible Causes

l Disks are removed.l Disks are faulty.

Procedure

Step 1 Check whether any disk is removed.1. If yes, reinsert the removed disk. If alarm Controller Write Cache Is Disabled

persists=>Step 2.2. If no=>Step 2.

Step 2 Check whether alarms are generated indicating disk faults.1. If yes, replace the faulty disks. If alarm Controller Write Cache Is Disabled persists=>Step

3.2. If no=>Step 3.

Step 3 Collect related information and contact technical support engineers.

----End

Related Information

None

2.167 0x10C000C Write Cache For A Cache Partition IsDisabled

Description

Write cache for a cache partition is disabled.

Attribute

ID Event Level Automatically Cleared

0x10C000C Major Yes

OceanStor 5300 V3&5500 V3&5600 V3&5800 V3&6800V3 Storage SystemEvent Reference 2 Troubleshooting Events

Issue 04 (2015-06-10) Huawei Proprietary and ConfidentialCopyright © Huawei Technologies Co., Ltd.

146

Impact on the System

N/A.

Possible Causes

l Disks are removed.

l Disks are faulty.

Procedure

Step 1 Check whether any disk is removed.

1. If yes, reinsert the removed disk. If the alarm persists=>Step 2.

2. If no=>Step 2.

Step 2 Check whether alarms are generated indicating disk faults.

1. If yes, replace the faulty disks. If the alarm persists=>Step 3.

2. If no=>Step 3.

Step 3 Collect related information and contact technical support engineers.

----End

Related Information

None

2.168 0xFD0008 LUN Migration Is Faulty

Description

LUN Migration is faulty.

Attribute

ID Event Level Automatically Cleared

0xFD0008 Major Yes

Impact on the System

N/A.

OceanStor 5300 V3&5500 V3&5600 V3&5800 V3&6800V3 Storage SystemEvent Reference 2 Troubleshooting Events

Issue 04 (2015-06-10) Huawei Proprietary and ConfidentialCopyright © Huawei Technologies Co., Ltd.

147

Possible Causes

l Storage pools are faulty.

l The source LUN of LUN migration is faulty.

l The target LUN of LUN migration is faulty.

Procedure

Step 1 Check whether alarms are generated for the storage pools that house the source and target LUNs.1. If yes, handle alarms with recommended actions. If the alarm persists=>Step 2.2. If no=>Step 2.

Step 2 Collect related information and contact technical support engineers.

----End

Related Information

None

2.169 0xF00CE002B From An Expansion Port, DiskEnclosures And High-Density Disk Enclosures Are Mix-Connected

Description

From an expansion port, disk enclosures and high-density disk enclosures are mix-connected.

Attribute

ID Event Level Automatically Cleared

0xF00CE002B Warning Yes

Impact on the System

Subsequent disk enclosures that are of different types cannot be connected.

Possible Causes

From the same expansion port, disk enclosures and high-density disk enclosures are mix-connected.

Procedure

Step 1 Check whether from the port the connected disk enclosures are of the same type.

OceanStor 5300 V3&5500 V3&5600 V3&5800 V3&6800V3 Storage SystemEvent Reference 2 Troubleshooting Events

Issue 04 (2015-06-10) Huawei Proprietary and ConfidentialCopyright © Huawei Technologies Co., Ltd.

148

1. If yes=>Step 2.

2. If no=>Replace some disk enclosures to ensure that all disk enclosures connected from theexpansion port are of the same type. If the alarm persists=>Step 2.

Step 2 Collect related information and contact technical support engineers.

----End

Related Information

None

2.170 0xF000B0063 External LUN Has Links To Only OneController

Description

External LUN has links to only one controller.

Attribute

ID Event Level Automatically Cleared

0xF000B0063 Major Yes

Impact on the System

As no redundant link is available, the reliability is reduced and online upgrade may fail.

Possible Causes

l Only one link is connected.

l The initiator of a link is deleted.

l The mapping of the external LUN is deleted.

Procedure

Step 1 Check whether only one controller has a link to the external LUN.

1. If yes, connect the link based on the standard network in the related product manual.

2. If no=>Step 2.

Step 2 Check whether the initiator of a link is removed.

1. If yes, add the initiator back.

2. If no=>Step 3.

Step 3 Check whether the mapping of the corresponding external LUN has been deleted.

OceanStor 5300 V3&5500 V3&5600 V3&5800 V3&6800V3 Storage SystemEvent Reference 2 Troubleshooting Events

Issue 04 (2015-06-10) Huawei Proprietary and ConfidentialCopyright © Huawei Technologies Co., Ltd.

149

1. If yes, add the mapping.2. If no=>Step 4.

Step 4 Collect related event information and contact technical support.

----End

Related InformationNone

2.171 0xF000B0064 External LUN Offline

DescriptionExternal LUN is offline.

Attribute

ID Event Level Automatically Cleared

0xF000B0064 Major Yes

Impact on the SystemThe eDevLUN and related features become faulty.

Possible Causesl The external LUN's link is disconnected.l The initiator of the external LUN's link is deleted.l The mapping of the external LUN is deleted.

Procedure

Step 1 Check whether link between the external array and the local array is disconnected.1. If yes, connect the link based on the standard network in the related product manual. If the

fault persists=>Step 2.2. If no=>Step 2.

Step 2 Check whether the initiator of a link is removed.1. If yes, add the initiator back. If the fault persists=>Step 3.2. If no=>Step 3.

Step 3 Check whether the mapping of the corresponding external LUN has been deleted.1. If yes, add the mapping. If the fault persists=>Step 4.2. If no=>Step 4.

OceanStor 5300 V3&5500 V3&5600 V3&5800 V3&6800V3 Storage SystemEvent Reference 2 Troubleshooting Events

Issue 04 (2015-06-10) Huawei Proprietary and ConfidentialCopyright © Huawei Technologies Co., Ltd.

150

Step 4 Collect related event information and contact technical support.

----End

Related Information

None

2.172 0xF000B0065 External LUN Faulty

Description

External LUN is faulty.

Attribute

ID Event Level Automatically Cleared

0xF000B0065 Major Yes

Impact on the System

The eDevLun and related features become faulty.

Possible Causes

l The external LUN is faulty.

l The initiator of the external LUN's link is deleted.

l The mapping of the external LUN is deleted.

Procedure

Step 1 Check whether any disk is removed from the external array.

1. If yes, reinsert the disk to recover the external LUN. If the fault persists=>Step 2.

2. If no=>Step 2.

Step 2 Check whether the initiator of a link is removed.

1. If yes, add the initiator back. If the fault persists=>Step 3.

2. If no=>Step 3.

Step 3 Check whether the mapping of the corresponding external LUN has been deleted.

1. If yes, add the mapping. If the fault persists=>Step 4.

2. If no=>Step 4.

Step 4 Run the LUN scan command on the heterogeneous array to which the external LUN belongs. Ifthe alarm persists=>Step 5.

OceanStor 5300 V3&5500 V3&5600 V3&5800 V3&6800V3 Storage SystemEvent Reference 2 Troubleshooting Events

Issue 04 (2015-06-10) Huawei Proprietary and ConfidentialCopyright © Huawei Technologies Co., Ltd.

151

Step 5 Collect related event information and contact technical support.

----End

Related Information

None

2.173 0xF000B0066 External LUN Downsized

Description

External LUN is downsized.

Attribute

ID Event Level Automatically Cleared

0xF000B0066 Major Yes

Impact on the System

The eDevLUN and related features become faulty.

Possible Causes

The external LUN is downsized.

Procedure

Step 1 Expand the capacity of the corresponding external LUN to not less than its original capacity. Ifthe alarm persists=>Step 2.

Step 2 Run the LUN scan command on the heterogeneous array to which the external LUN belongs.

----End

Related Information

None

2.174 0xF000B0052 Incompatible Heterogeneous ArrayConnected To The System

Description

Incompatible heterogeneous array is connected to the system.

OceanStor 5300 V3&5500 V3&5600 V3&5800 V3&6800V3 Storage SystemEvent Reference 2 Troubleshooting Events

Issue 04 (2015-06-10) Huawei Proprietary and ConfidentialCopyright © Huawei Technologies Co., Ltd.

152

Attribute

ID Event Level Automatically Cleared

0xF000B0052 Warning No

Impact on the System

The incompatibility issue may interrupt services.

Possible Causes

l An incorrect storage array is connected.

l The system lacks the support package for the heterogeneous array.

Procedure

Step 1 If the external LUNs of this heterogeneous array have been used to create eDevLUN, pleasedelete these eDevLUNs first.

Step 2 Disconnect all physical links between the heterogeneous array and the local array. If the systemhas connected to other heterogeneous arrays whose SN can not be obtained, or the system hasconnected to other incompatible arrays, you need to manually clear the alarms.

Step 3 If you have to connect this heterogeneous array, load the support package first and then reconnectthe heterogeneous array.

----End

Related Information

None

2.175 0xF000B005D FC Link Of Heterogeneous ArrayDisconnected

Description

FC link of heterogeneous array is disconnected.

Attribute

ID Event Level Automatically Cleared

0xF000B005D Major No

OceanStor 5300 V3&5500 V3&5600 V3&5800 V3&6800V3 Storage SystemEvent Reference 2 Troubleshooting Events

Issue 04 (2015-06-10) Huawei Proprietary and ConfidentialCopyright © Huawei Technologies Co., Ltd.

153

Impact on the System

This may cause the external LUN to have a single link or get offline.

Possible Causes

l The external array is powered off.

l An FC switch is powered off.

l An FC link is disconnected.

Procedure

Step 1 Check whether the external array is powered off. If the external array is powered off, power iton again. If the alarm persists=>Step 2.

Step 2 Check whether any FC switch is powered off. If any FC switch is powered off, power it on again.If the alarm persists=>Step 3.

Step 3 Check whether any FC link is removed or damaged.

1. If any FC link is removed, reconnect it correctly. If the alarm persists=>Step 4.

2. If any FC link is damaged, replace it with a new link and connect the new link correctly.If the alarm persists=>Step 4.

Step 4 Collect related event information and contact technical support engineers.

----End

Related Information

None

2.176 0xF000B0060 iSCSI Link Of Heterogeneous ArrayDisconnected

Description

iSCSI link of heterogeneous array is disconnected.

Attribute

ID Event Level Automatically Cleared

0xF000B0060 Major No

Impact on the System

This may cause the external LUN to have a single link or get offline.

OceanStor 5300 V3&5500 V3&5600 V3&5800 V3&6800V3 Storage SystemEvent Reference 2 Troubleshooting Events

Issue 04 (2015-06-10) Huawei Proprietary and ConfidentialCopyright © Huawei Technologies Co., Ltd.

154

Possible Causesl The external array is powered off.l An GE switch is powered off.l An iSCSI link is disconnected.

Procedure

Step 1 Check whether the external array is powered off. If the external array is powered off, power iton again. If the alarm persists=>Step 2.

Step 2 Check whether any GE switch is powered off. If any GE switch is powered off, power it onagain. If the alarm persists=>Step 3.

Step 3 Check whether any iSCSI link is removed or damaged.1. If any iSCSI link is removed, reconnect it correctly. If the alarm persists=>Step 4.2. If any iSCSI link is damaged, replace it with a new link and connect the new link correctly.

If the alarm persists=>Step 4.

Step 4 Collect related event information and contact technical support engineers.

----End

Related InformationNone

2.177 0xF000B0061 FC Link Of Heterogeneous Array Faulty

DescriptionFC link of heterogeneous array is faulty.

Attribute

ID Event Level Automatically Cleared

0xF000B0061 Major No

Impact on the SystemData cannot be transferred over this link, reducing reliability.

Possible Causesl The initiator is deleted.l The link has a bit error.l The link connection is faulty.

OceanStor 5300 V3&5500 V3&5600 V3&5800 V3&6800V3 Storage SystemEvent Reference 2 Troubleshooting Events

Issue 04 (2015-06-10) Huawei Proprietary and ConfidentialCopyright © Huawei Technologies Co., Ltd.

155

Procedure

Step 1 Check whether the initiator of the link has been removed.

1. If yes, add the initiator back. If the fault persists=>Step 2.

2. If no=>Step 2.

Step 2 Check whether the link is properly connected or damaged.

1. If the link is not properly connected, reinsert it. If the fault persists=>Step 3.

2. If the link is damaged, replace it with a new one and insert the new one to the original port.If the fault persists=>Step 3.

Step 3 Check whether any switch is damaged. If a switch is damaged, replace it with a new one andreinsert all links to the new switch correctly. If the fault persists=>Step 4.

Step 4 Collect related event information and contact technical support engineers.

----End

Related Information

None

2.178 0xF000B0062 iSCSI Link Of Heterogeneous ArrayFaulty

Description

iSCSI link of heterogeneous array is faulty.

Attribute

ID Event Level Automatically Cleared

0xF000B0062 Major No

Impact on the System

Data cannot be transferred over this link, reducing reliability.

Possible Causes

l The initiator is deleted.

l The link has a bit error.

l The link connection is faulty.

OceanStor 5300 V3&5500 V3&5600 V3&5800 V3&6800V3 Storage SystemEvent Reference 2 Troubleshooting Events

Issue 04 (2015-06-10) Huawei Proprietary and ConfidentialCopyright © Huawei Technologies Co., Ltd.

156

Procedure

Step 1 Check whether the initiator of the link has been removed.

1. If yes, add the initiator back. If the fault persists=>Step 2.

2. If no=>Step 2.

Step 2 Check whether the link is properly connected or damaged.

1. If the link is not properly connected, reinsert it. If the fault persists=>Step 3.

2. If the link is damaged, replace it with a new one and insert the new one to the original port.If the fault persists=>Step 3.

Step 3 Check whether any switch is damaged. If a switch is damaged, replace it with a new one andreinsert all links to the new switch correctly. If the fault persists=>Step 4.

Step 4 Collect related event information and contact technical support engineers.

----End

Related Information

None

2.179 0x200F000A005B The Hard Disk Is Isolated

Description

The hard disk is isolated.

Attribute

ID Event Level Automatically Cleared

0x200F000A005B Major Yes

Impact on the System

The hard disk is in single-link state.

Possible Causes

N/A.

Procedure

Collect related information and contact technical support engineers.

----End

OceanStor 5300 V3&5500 V3&5600 V3&5800 V3&6800V3 Storage SystemEvent Reference 2 Troubleshooting Events

Issue 04 (2015-06-10) Huawei Proprietary and ConfidentialCopyright © Huawei Technologies Co., Ltd.

157

Related InformationNone

2.180 0xF00280045 File System Is Faulty

DescriptionFile system is faulty.

Attribute

ID Event Level Automatically Cleared

0xF00280045 Critical Yes

Impact on the SystemFile systems cannot be accessed.

Possible CausesThe related disks are faulty.

Procedure

Collect related information and contact technical support engineers.

----End

Related InformationNone

2.181 0xF00280046 File System Has A Medium Error

DescriptionFile system has a medium error.

Attribute

ID Event Level Automatically Cleared

0xF00280046 Critical Yes

OceanStor 5300 V3&5500 V3&5600 V3&5800 V3&6800V3 Storage SystemEvent Reference 2 Troubleshooting Events

Issue 04 (2015-06-10) Huawei Proprietary and ConfidentialCopyright © Huawei Technologies Co., Ltd.

158

Impact on the System

The reliability of data stored on the file system deteriorates.

Possible Causes

The disk has bad sectors.

Procedure

Step 1 1 Check whether the file system has a backup.

1. If yes, rewrite the file system by using the backup data for data recovery purposes.

2. If no, contact technical support engineers.

----End

Related Information

None

2.182 0xF00280047 Remaining Capacity In A File System IsInsufficient

Description

The remaining capacity in a file system is insufficient.

Attribute

ID Event Level Automatically Cleared

0xF00280047 Major Yes

Impact on the System

l Files may be writted in writethrough mode, degrading file system read and writeperformance.

l Users may fail to write data into the file system.

Possible Causes

The rate of used capacity in the file system exceeds the alarm threshold.

Procedure

OceanStor 5300 V3&5500 V3&5600 V3&5800 V3&6800V3 Storage SystemEvent Reference 2 Troubleshooting Events

Issue 04 (2015-06-10) Huawei Proprietary and ConfidentialCopyright © Huawei Technologies Co., Ltd.

159

Expand the capacity of the file system or delete unnecessary files.

----End

Related Information

None

2.183 0xF00280048 Used Resource Of A File System QuotaExceeds The Soft Quota

Description

Used resource of a file system quota exceeds the soft quota.

Attribute

ID Event Level Automatically Cleared

0xF00280048 Major Yes

Impact on the System

N/A.

Possible Causes

Used resource of a file system quota exceeds the soft quota.

Procedure

Please expand the soft quota or delete some files.

----End

Related Information

None

2.184 0xF00280049 File System Has A Checksum Error

Description

File system has a checksum error.

OceanStor 5300 V3&5500 V3&5600 V3&5800 V3&6800V3 Storage SystemEvent Reference 2 Troubleshooting Events

Issue 04 (2015-06-10) Huawei Proprietary and ConfidentialCopyright © Huawei Technologies Co., Ltd.

160

Attribute

ID Event Level Automatically Cleared

0xF00280049 Critical Yes

Impact on the System

None

Possible Causes

N/A.

Procedure

Step 1 Check whether the filesystem has a backup.

1. If yes, rewrite the filesystem by using the backup data for data recovery purposes.

2. If no =>Step 2.

Step 2 Collect related information and contact technical support engineers.

----End

Related Information

None

2.185 0x100F0028004A File System Has A MemoryAllocation Error

Description

File system has a memory alloc error.

Attribute

ID Event Level Automatically Cleared

0x100F0028004A Critical Yes

Impact on the System

None

OceanStor 5300 V3&5500 V3&5600 V3&5800 V3&6800V3 Storage SystemEvent Reference 2 Troubleshooting Events

Issue 04 (2015-06-10) Huawei Proprietary and ConfidentialCopyright © Huawei Technologies Co., Ltd.

161

Possible CausesN/A.

Procedure

Collect related information and contact technical support engineers.

----End

Related InformationNone

2.186 0x10A0021 Failed To Add The New Disk To The DiskDomain

DescriptionThe encrypt type of the new disk is inconsistent with the disk domain.

Attribute

ID Event Level Automatically Cleared

0x10A0021 Major No

Impact on the SystemThe type of disk domain is different from the new disk. The new disk is unavailable.

Possible Causesl The disk domain is not encrypted, but the encryption function of the disk is enabled.l The disk domain is encrypted, but the disk does not have the encryption function.l The encryption type of the new disk is different from that of the disks in the disk domain.

Procedure

Step 1 Check the encrypt status of the disk domain.1. Check encrypt status of the disk domain.

l The disk domain is encrypted=>Step 2.l The disk domain is not encrypted=>Step 1.2.

2. Disable the encryption function of the disk manually or insert a disk without the encryptionfunction.

OceanStor 5300 V3&5500 V3&5600 V3&5800 V3&6800V3 Storage SystemEvent Reference 2 Troubleshooting Events

Issue 04 (2015-06-10) Huawei Proprietary and ConfidentialCopyright © Huawei Technologies Co., Ltd.

162

l If the alarm persists=>Step 3.

Step 2 Check encrypt status of the disk.1. Check the disk encrypt status.

l The disk is not encrypted=>Step 2.3.l The disk is encrypted=>Step 2.2.

2. Check the encrypt type of the new disk and the other disks in the disk domain.l The encrypted type of disks is the same=>Step 3.l If not =>Step 2.3.

3. Insert another disk with the same encryption type.l If the alarm persists=>Step 3.

Step 3 Collect related information and contact technical support engineers.

----End

Related InformationNone

2.187 0x10A0020 A New Disk Fails to Be Added To The DiskDomain

DescriptionThe capacity of the newly replaced disk is insufficient so that the disk cannot be added to thisdisk domain.

Attribute

ID Event Level Automatically Cleared

0x10A0020 Major Yes

Impact on the SystemThe disk fails to work.

Possible CausesA member disk of the disk domain is replaced by a new disk with smaller capacity.

Procedure

Step 1 Replace the newly added disk with a disk that meets system requirements. If the alarm persists=>Step 2.

OceanStor 5300 V3&5500 V3&5600 V3&5800 V3&6800V3 Storage SystemEvent Reference 2 Troubleshooting Events

Issue 04 (2015-06-10) Huawei Proprietary and ConfidentialCopyright © Huawei Technologies Co., Ltd.

163

Step 2 Collect related information and contact technical support engineers.

----End

Related Information

None

2.188 0xF4045000E Adding To An AD Domain Fails

Description

Adding to an AD domain([domain_name]) fails.

Attribute

ID Event Level Automatically Cleared

0xF4045000E Major No

Impact on the System

Domain authentication fails. Domain services are affected.

Possible Causes

l The device is incorrectly communicating with the AD domain controller.

l The DNS of the device is incorrectly configured.

l The system time of the device is different from that of the AD domain controller.

Procedure

Step 1 Check the network connectivity between the device and AD domain controller.

1. Check whether the device is correctly communicating with the AD domain controller.

l If yes=>Step 2.

l If no=>Step 1.2.

2. Contact the network administrator to rectify the network fault. Then check whether thealarm is cleared.

l If yes=>Step 2.

l If no=>no further action is required.

Step 2 Check the DNS configuration of the device.

1. Check whether the DNS of the device is incorrectly configured.

l If yes=>Step 3.

l If no=>Step 2.2.

OceanStor 5300 V3&5500 V3&5600 V3&5800 V3&6800V3 Storage SystemEvent Reference 2 Troubleshooting Events

Issue 04 (2015-06-10) Huawei Proprietary and ConfidentialCopyright © Huawei Technologies Co., Ltd.

164

2. Reconfigure the DNS. Then check whether the alarm is cleared.

l If yes=>Step 3.

l If no=>no further action is required.

Step 3 Check the system time of the device and that of the AD domain controller.

1. Check whether the difference between the system time of the device and that of the ADdomain controller is less than 5 minutes.

l If yes=>Step 4.

l If no=>Step 3.2.

2. Ensure that the difference between the system time of the device and that of the AD domaincontroller is less than 5 minutes. Then check whether the alarm is cleared.

l If yes=>Step 4.

l If no=>no further action is required.

Step 4 Contact technical support engineers.

----End

Related Information

None

2.189 0x200F4045000F No Domain Controller Is Available

Description

A NAS node is disconnected from all domain controllers.

Attribute

ID Event Level Automatically Cleared

0x200F4045000F Major No

Impact on the System

Domain authentication fails. Domain services are affected.

Possible Causes

l The AD domain controller is shut down.

l The device is incorrectly communicating with the AD domain controller.

Procedure

Step 1 Check the status of the AD domain controller.

OceanStor 5300 V3&5500 V3&5600 V3&5800 V3&6800V3 Storage SystemEvent Reference 2 Troubleshooting Events

Issue 04 (2015-06-10) Huawei Proprietary and ConfidentialCopyright © Huawei Technologies Co., Ltd.

165

1. Check whether the AD domain controller is started.l If yes=>Step 2.l If no=>Step 1.2.

2. Start the AD domain controller. Then check whether the alarm is cleared.l If yes=>no further action is required.l If no=>Step 2.

Step 2 Check the network connectivity between the device and AD domain controller.1. Check whether the device is correctly communicating with the AD domain controller.

l If yes=>Step 3.l If no=>Step 2.2.

2. Contact the network administrator to rectify the network fault. Then check whether thealarm is cleared.l If yes=>no further action is required.l If no=>Step 3.

Step 3 Contact technical support engineers.

----End

Related InformationNone

2.190 0xF40020001 The Ndmp Service Process Is Abnormal

DescriptionThe NDMP service process is abnormal.

AttributeID Event Level Automatically Cleared

0xF40020001 Major No

Impact on the SystemN/A.

Possible CausesThe critical process is abnormal.

Procedure

OceanStor 5300 V3&5500 V3&5600 V3&5800 V3&6800V3 Storage SystemEvent Reference 2 Troubleshooting Events

Issue 04 (2015-06-10) Huawei Proprietary and ConfidentialCopyright © Huawei Technologies Co., Ltd.

166

Contact technical support engineers.

----End

Related Information

None

2.191 0xF40020002 A Service Port Conflicts

Description

A service port conflicts.

Attribute

ID Event Level Automatically Cleared

0xF40020002 Major No

Impact on the System

Service cannot be accessed.

Possible Causes

The service port is occupied by another program.

Procedure

View the system port list and stop the program that occupies the service port.

----End

Related Information

None

2.192 0xF0D30004 Fan Module Is Faulty

Description

Fan hardware is faulty, causing abnormal fan speed.

OceanStor 5300 V3&5500 V3&5600 V3&5800 V3&6800V3 Storage SystemEvent Reference 2 Troubleshooting Events

Issue 04 (2015-06-10) Huawei Proprietary and ConfidentialCopyright © Huawei Technologies Co., Ltd.

167

Attribute

ID Event Level Automatically Cleared

0xF0D30004 Major Yes

Impact on the System

l Engines or disk enclosures will overheat, affecting the normal operation of the storagesystem.

l The storage I/O performance may deteriorate.

Possible Causes

The fan module is faulty.

Procedure

Step 1 Replace the fan module. If the alarm persists=>Step 2.

Step 2 Collect related information and contact technical support engineers.

----End

Related Information

None

2.193 0xF00D1001F Management Module Is Faulty

Description

Management module hardware is faulty.

Attribute

ID Event Level Automatically Cleared

0xF00D1001F Major Yes

Impact on the System

l The reliability of the storage system deteriorates.

l The security of the storage system deteriorates.

OceanStor 5300 V3&5500 V3&5600 V3&5800 V3&6800V3 Storage SystemEvent Reference 2 Troubleshooting Events

Issue 04 (2015-06-10) Huawei Proprietary and ConfidentialCopyright © Huawei Technologies Co., Ltd.

168

Possible Causes

l The management module is faulty.

l SSDs are faulty.

Procedure

Step 1 Replace the management module. If the alarm persists=>Step 2.

Step 2 Collect related information and contact technical support engineers.

----End

Related Information

None

2.194 0xF00D10020 Interface Module Is Faulty

Description

Interface module hardware is faulty.

Attribute

ID Event Level Automatically Cleared

0xF00D10020 Major Yes

Impact on the System

All ports on the interface module fail to function.

Possible Causes

The interface module is faulty.

Procedure

Step 1 Replace the interface module. If the alarm persists=>Step 2.

Step 2 Collect related information and contact technical support engineers.

----End

Related Information

None

OceanStor 5300 V3&5500 V3&5600 V3&5800 V3&6800V3 Storage SystemEvent Reference 2 Troubleshooting Events

Issue 04 (2015-06-10) Huawei Proprietary and ConfidentialCopyright © Huawei Technologies Co., Ltd.

169

2.195 0xF00170018 The Power Module Is Incompatible WithThe Storage System

DescriptionThe power module is incompatible with the storage system.

Attribute

ID Event Level Automatically Cleared

0xF00170018 Major Yes

Impact on the Systeml The reliability of the storage system deteriorates.l The storage system may not work correctly.

Possible CausesThe power module is incompatible with the storage system.

Procedure

Collect related information and contact technical support engineers.

----End

Related InformationNone

2.196 0xF00EA0018 The System Failed To Monitor AnOptical/Electrical Module

DescriptionThe system failed to monitor an optical/electrical module.

OceanStor 5300 V3&5500 V3&5600 V3&5800 V3&6800V3 Storage SystemEvent Reference 2 Troubleshooting Events

Issue 04 (2015-06-10) Huawei Proprietary and ConfidentialCopyright © Huawei Technologies Co., Ltd.

170

Attribute

ID Event Level Automatically Cleared

0xF00EA0018 Major Yes

Impact on the SystemN/A.

Possible Causesl The optical module is faulty.l The electrical module is faulty.l The I2C communication is abnormal.

Procedure

Step 1 Check whether an alarm is generated indicating an optical/electrical module fault.1. If yes, replace the faulty optical/electrical module. If the alarm persists=>Step 2.2. If no=>Step 2.

Step 2 Replace the interface module where the faulty optical/electrical module resides. If the alarmpersists =>Step 3.

Step 3 Replace the controller corresponding to the faulty optical/electrical module. If the alarmpersists=>Step 4.

Step 4 Collect related information and contact technical support engineers.

----End

Related InformationNone

2.197 0x200F0D1000D The System Failed To Power Off AnInterface Module

DescriptionThe system failed to power off an interface module.

Attribute

ID Event Level Automatically Cleared

0x200F0D1000D Warning Yes

OceanStor 5300 V3&5500 V3&5600 V3&5800 V3&6800V3 Storage SystemEvent Reference 2 Troubleshooting Events

Issue 04 (2015-06-10) Huawei Proprietary and ConfidentialCopyright © Huawei Technologies Co., Ltd.

171

Impact on the SystemN/A.

Possible CausesN/A.

Procedure

Collect related information and contact technical support engineers.

----End

Related InformationNone

2.198 0x200F0D10010 The System Failed To Power On AnInterface Module

DescriptionThe system failed to power on an interface module.

AttributeID Event Level Automatically Cleared

0x200F0D10010 Warning Yes

Impact on the SystemN/A.

Possible CausesN/A.

Procedure

Collect related information and contact technical support engineers.

----End

OceanStor 5300 V3&5500 V3&5600 V3&5800 V3&6800V3 Storage SystemEvent Reference 2 Troubleshooting Events

Issue 04 (2015-06-10) Huawei Proprietary and ConfidentialCopyright © Huawei Technologies Co., Ltd.

172

Related Information

None

2.199 0x200F00D10017 The System Failed to Power Off AnInterface Module

Description

The system failed to power off an interface module.

Attribute

ID Event Level Automatically Cleared

0x200F00D10017 Warning Yes

Impact on the System

N/A.

Possible Causes

N/A.

Procedure

Collect related information and contact technical support engineers.

----End

Related Information

None

2.200 0x200F00D1001C The System Failed to Power On AnInterface Module

Description

The system failed to power on an interface module.

OceanStor 5300 V3&5500 V3&5600 V3&5800 V3&6800V3 Storage SystemEvent Reference 2 Troubleshooting Events

Issue 04 (2015-06-10) Huawei Proprietary and ConfidentialCopyright © Huawei Technologies Co., Ltd.

173

Attribute

ID Event Level Automatically Cleared

0x200F00D1001C Warning Yes

Impact on the System

N/A.

Possible Causes

N/A.

Procedure

Collect related information and contact technical support engineers.

----End

Related Information

None

2.201 0x200F00C90088 Succeeded In Deleting AllConfigurations Of System

Description

Succeeded in deleting all configurations of system.

Attribute

ID Event Level Automatically Cleared

0x200F00C90088 Warning Yes

Impact on the System

N/A.

Possible Causes

N/A.

OceanStor 5300 V3&5500 V3&5600 V3&5800 V3&6800V3 Storage SystemEvent Reference 2 Troubleshooting Events

Issue 04 (2015-06-10) Huawei Proprietary and ConfidentialCopyright © Huawei Technologies Co., Ltd.

174

Procedure

N/A.

----End

Related Information

None

2.202 0x200F00C90089 Failed To Delete All ConfigurationsOf System

Description

Failed to delete all configurations of system.

Attribute

ID Event Level Automatically Cleared

0x200F00C90089 Warning Yes

Impact on the System

N/A.

Possible Causes

N/A.

Procedure

N/A.

----End

Related Information

None

OceanStor 5300 V3&5500 V3&5600 V3&5800 V3&6800V3 Storage SystemEvent Reference 2 Troubleshooting Events

Issue 04 (2015-06-10) Huawei Proprietary and ConfidentialCopyright © Huawei Technologies Co., Ltd.

175

2.203 0xF00CA0008 The Super Administrator Needs ToReview User Account Information

DescriptionWhen the user account information review switch is on, the super administrator needs to reviewuser account information periodically. Clear the alarm manually when it is done.

Attribute

ID Event Level Automatically Cleared

0xF00CA0008 Warning No

Impact on the SystemN/A.

Possible CausesThe super administrator needs to review user account information periodically.

Procedure

After reviewing user account information, clear the alarm manually.

----End

Related InformationNone

2.204 0xF40450029 No LDAP/NIS Server Is Available

DescriptionA NAS node is disconnected from all LDAP/NIS Servers.

Attribute

ID Event Level Automatically Cleared

0xF40450029 Major Yes

OceanStor 5300 V3&5500 V3&5600 V3&5800 V3&6800V3 Storage SystemEvent Reference 2 Troubleshooting Events

Issue 04 (2015-06-10) Huawei Proprietary and ConfidentialCopyright © Huawei Technologies Co., Ltd.

176

Impact on the SystemLDAP/NIS authentication fails. LDAP/NIS services are affected.

Possible Causes

l The LDAP/NIS server is shut down.l The device is incorrectly communicating with the LDAP/NIS server.

Procedure

Step 1 Check the status of the LDAP/NIS server.1. Check whether the LDAP/NIS server is started.

l If yes=>Step 2.l If no=>Step 1.2.

2. Start the LDAP/NIS server. Then check whether the alarm is cleared.l If yes=>no further action is required.l If no=>Step 2.

Step 2 Check the network connectivity between the device and LDAP/NIS server.1. Check whether the device is correctly communicating with the LDAP/NIS server.

l If yes=>Step 3.l If no=>Step 2.2.

2. Contact the network administrator to rectify the network fault. Then check whether thealarm is cleared.l If yes=>no further action is required.l If no=>Step 3.

Step 3 Collect related information and contact technical support engineers.

----End

Related InformationNone

2.205 0xF02470010 Mirror Copy Is Abnormally Interrupted

DescriptionA mirror copy is abnormally interrupted.

Attribute

ID Event Level Automatically Cleared

0xF02470010 Critical Yes

OceanStor 5300 V3&5500 V3&5600 V3&5800 V3&6800V3 Storage SystemEvent Reference 2 Troubleshooting Events

Issue 04 (2015-06-10) Huawei Proprietary and ConfidentialCopyright © Huawei Technologies Co., Ltd.

177

Impact on the System

Data cannot be written onto or read from the mirror copy.

Possible Causes

l The storage pool is faulty.

l The mirror copy is faulty.

Procedure

Step 1 Check whether alarms are generated for the storage pool that houses the mirror copy.

1. If yes, handle alarms with recommended actions. If the alarm persists=>Step 2.

2. If no=>Step 2.

Step 2 Collect related information and contact technical support engineers.

----End

Related Information

None

2.206 0xF02470011 Mirror Copy Is Unavailable

Description

A mirror copy is unavailable.

Attribute

ID Event Level Automatically Cleared

0xF02470011 Critical Yes

Impact on the System

The mirror copy is unavailable.

Possible Causes

Configurations of the mirror copy are abnormal.

OceanStor 5300 V3&5500 V3&5600 V3&5800 V3&6800V3 Storage SystemEvent Reference 2 Troubleshooting Events

Issue 04 (2015-06-10) Huawei Proprietary and ConfidentialCopyright © Huawei Technologies Co., Ltd.

178

Procedure

Step 1 Please remove the mirror copy. If the operation fails=>Step 2.

Step 2 Collect related information and contact technical support engineers.

----End

Related Information

None

2.207 0xF032C0001 The SSH Service Is Abnormal

Description

The SSH service of a controller is abnormal, so users cannot log in to the controller using SSH.

Attribute

ID Event Level Automatically Cleared

0xF032C0001 Warning No

Impact on the System

Users cannot log in to the controller using SSH.

Possible Causes

l The SSH-based login management process is abnormal.

l The controller is faulty.

Procedure

Contact technical support engineers.

----End

Related Information

None

OceanStor 5300 V3&5500 V3&5600 V3&5800 V3&6800V3 Storage SystemEvent Reference 2 Troubleshooting Events

Issue 04 (2015-06-10) Huawei Proprietary and ConfidentialCopyright © Huawei Technologies Co., Ltd.

179

2.208 0xF032C0002 The FTP Service Is Abnormal

Description

The FTP service of a controller is abnormal, so data cannot be transferred through FTP.

Attribute

ID Event Level Automatically Cleared

0xF032C0002 Warning No

Impact on the System

Data such as log management data cannot be transferred.

Possible Causes

l The FTP-based file transfer process is abnormal.

l The controller is faulty.

Procedure

Contact technical support engineers.

----End

Related Information

None

2.209 0xF032C0003 NTP Time Synchronization Is Abnormal

Description

A controller is incorrectly connected to an NTP server, so time synchronization between themfails.

Attribute

ID Event Level Automatically Cleared

0xF032C0003 Warning No

OceanStor 5300 V3&5500 V3&5600 V3&5800 V3&6800V3 Storage SystemEvent Reference 2 Troubleshooting Events

Issue 04 (2015-06-10) Huawei Proprietary and ConfidentialCopyright © Huawei Technologies Co., Ltd.

180

Impact on the SystemTime synchronization between the controller and NTP server fails.

Possible Causesl The NTP client is faulty.l The NTP server is faulty.l The controller is faulty.

Procedure

Step 1 Check whether the network connection between the controller and NTP server is correct.1. If yes=>Step 2.2. If no=>rectify the network connection fault. If the alarm persists=>Step 2.

Step 2 Check whether the NTP service of the NTP server is correct.1. If yes=>Step 3.2. If no=>recover the NTP service. If the alarm persists=>Step 3.

Step 3 Contact technical support engineers.

----End

Related InformationNone

2.210 0xF032C0004 The Network Protocol Stack Of AController Is Abnormal

DescriptionA controller fails to ping 127.0.0.1.

AttributeID Event Level Automatically Cleared

0xF032C0004 Critical No

Impact on the SystemNetwork packets fail to be sent.

Possible CausesThe controller is faulty.

OceanStor 5300 V3&5500 V3&5600 V3&5800 V3&6800V3 Storage SystemEvent Reference 2 Troubleshooting Events

Issue 04 (2015-06-10) Huawei Proprietary and ConfidentialCopyright © Huawei Technologies Co., Ltd.

181

Procedure

Contact technical support engineers.

----End

Related InformationNone

2.211 0xF032C0005 The Process CPU Usage Is Too High

DescriptionThe CPU usage of a process in a controller exceeds a threshold.

Attribute

ID Event Level Automatically Cleared

0xF032C0005 Warning No

Impact on the SystemStorage system performance deteriorates.

Possible CausesThe service load is too heavy.

Procedure

Step 1 Check whether the service load of the host is too heavy.

Step 2 Collect related information and contact technical support engineers.

----End

Related InformationNone

2.212 0xF032C0006 The Process Memory Usage Is Too High

DescriptionThe memory usage of a process in a controller exceeds a threshold.

OceanStor 5300 V3&5500 V3&5600 V3&5800 V3&6800V3 Storage SystemEvent Reference 2 Troubleshooting Events

Issue 04 (2015-06-10) Huawei Proprietary and ConfidentialCopyright © Huawei Technologies Co., Ltd.

182

AttributeID Event Level Automatically Cleared

0xF032C0006 Warning No

Impact on the SystemStorage system performance deteriorates.

Possible CausesThe service load is too heavy.

Procedure

Collect related information and contact technical support engineers.

----End

Related InformationNone

2.213 0xF032C0007 A Directory Is Oversized

DescriptionDisk space occupied by all the files in a directory exceeds a threshold.

AttributeID Event Level Automatically Cleared

0xF032C0007 Warning No

Impact on the SystemStorage system performance deteriorates.

Possible CausesThe service load is too heavy.

Procedure

OceanStor 5300 V3&5500 V3&5600 V3&5800 V3&6800V3 Storage SystemEvent Reference 2 Troubleshooting Events

Issue 04 (2015-06-10) Huawei Proprietary and ConfidentialCopyright © Huawei Technologies Co., Ltd.

183

Collect related information and contact technical support engineers.

----End

Related Information

None

2.214 0xF032C0008 Excessive Files Exist In A Directory

Description

The number of files in a directory exceeds a threshold.

Attribute

ID Event Level Automatically Cleared

0xF032C0008 Warning No

Impact on the System

Storage system performance deteriorates.

Possible Causes

The service load is too heavy.

Procedure

Collect related information and contact technical support engineers.

----End

Related Information

None

2.215 0x200F00CF003A The Heartbeat Connection BetweenA Controller And A Management Module Is Interrupted

Description

The heartbeat connection between a controller and a management module is interrupted. As aresult, the controller cannot access the management module.

OceanStor 5300 V3&5500 V3&5600 V3&5800 V3&6800V3 Storage SystemEvent Reference 2 Troubleshooting Events

Issue 04 (2015-06-10) Huawei Proprietary and ConfidentialCopyright © Huawei Technologies Co., Ltd.

184

AttributeID Event Level Automatically Cleared

0x200F00CF003A Major Yes

Impact on the SystemThe controller cannot access the management module.

Possible Causesl The management module is faulty.l The controller is faulty.

Procedure

Step 1 Check whether alarms are generated indicating management module faults.1. If yes, replace the faulty management module. If the alarm persists, =>Step 2.2. If no, =>Step 2.

Step 2 Replace the corresponding controller. If the alarm persists, =>Step 3.

Step 3 Collect related information and contact technical support engineers.

----End

Related InformationNone

2.216 0xF00D10011 The PCIe Channel Between An InterfaceModule And A Controller Is Abnormal

DescriptionThe PCIe channel between an interface module and a controller is abnormal.

AttributeID Event Level Automatically Cleared

0xF00D10011 Major Yes

Impact on the SystemThe interface module fails to work correctly.

OceanStor 5300 V3&5500 V3&5600 V3&5800 V3&6800V3 Storage SystemEvent Reference 2 Troubleshooting Events

Issue 04 (2015-06-10) Huawei Proprietary and ConfidentialCopyright © Huawei Technologies Co., Ltd.

185

Possible Causes

l The interface module is faulty.

l The controller is faulty.

Procedure

Step 1 Check whether alarms are generated indicating interface module faults.

1. If yes, replace the faulty interface module. If the alarm persists, =>Step 2.

2. If no, =>Step 2.

Step 2 Replace the corresponding controller. If the alarm persists, =>Step 3.

Step 3 Collect related information and contact technical support engineers.

----End

Related Information

None

2.217 0xF000A005F Slow Disk Response

Description

A disk responds slowly.

Attribute

ID Event Level Automatically Cleared

0xF000A005F Major Yes

Impact on the System

The storage pool that houses the disk may have compromised I/O performance or even degrade.

Possible Causes

l The disk is faulty.

l Expansion ports are partially damaged.

l The disk is incorrectly inserted into its slot.

l Expansion modules are faulty.

l Disk enclosure backplanes are faulty.

OceanStor 5300 V3&5500 V3&5600 V3&5800 V3&6800V3 Storage SystemEvent Reference 2 Troubleshooting Events

Issue 04 (2015-06-10) Huawei Proprietary and ConfidentialCopyright © Huawei Technologies Co., Ltd.

186

Procedure

Step 1 Check whether alarms are generated indicating disk faults.1. If yes, replace the faulty disks. If alarm Slow Disk Response persists=>Step 2.2. If no=>Step 2.

Step 2 Check whether any expansion port is faulty.1. If yes, replace the interface module where the faulty port resides. If alarm Slow Disk

Response persists=>Step 3.2. If no=>Step 3.

Step 3 Check whether the disk is firmly inserted.1. If no, reinsert the disk. If alarm Slow Disk Response persists=>Step 4.2. If yes=>Step 4.

Step 4 Check whether alarms are generated indicating expansion module faults.1. If yes, replace the faulty expansion modules. If alarm Slow Disk Response persists=>Step

5.2. If no=>Step 5.

Step 5 Collect related information and contact technical support engineers.

----End

Related InformationNone

2.218 0x200F010D0029 Failed To Start Dispatch UpgradePackage

DescriptionFailed To Start Dispatch Upgrade Package

AttributeID Event Level Automatically Cleared

0x200F010D0029 Warning Yes

Impact on the SystemN/A.

Possible CausesN/A.

OceanStor 5300 V3&5500 V3&5600 V3&5800 V3&6800V3 Storage SystemEvent Reference 2 Troubleshooting Events

Issue 04 (2015-06-10) Huawei Proprietary and ConfidentialCopyright © Huawei Technologies Co., Ltd.

187

Procedure

Collect related information and contact technical support engineers.

----End

Related InformationNone

2.219 0x100F010D0031 Dispatch Upgrade Package Failed

DescriptionDispatch Upgrade Package Failed

Attribute

ID Event Level Automatically Cleared

0x100F010D0031 Warning Yes

Impact on the SystemN/A.

Possible CausesN/A.

Procedure

Collect related information and contact technical support engineers.

----End

Related InformationNone

OceanStor 5300 V3&5500 V3&5600 V3&5800 V3&6800V3 Storage SystemEvent Reference 2 Troubleshooting Events

Issue 04 (2015-06-10) Huawei Proprietary and ConfidentialCopyright © Huawei Technologies Co., Ltd.

188

2.220 0xF00D10012 Interface Module Is Inserted Into AnIncorrect Slot

DescriptionAn interface module is inserted into an incorrect slot in an engine or a disk enclosure.

AttributeID Event Level Automatically Cleared

0xF00D10012 Major Yes

Impact on the Systeml The interface module fails to work.l Controllers may fail to start.

Possible CausesInterface module is inserted into an incorrect slot.

Procedure

Step 1 Insert the interface module into a correct slot. If the alarm persists=>Step 2.

Step 2 Collect related information and contact technical support engineers.

----End

Related InformationNone

2.221 0xF00280074 File System Metadata Is Damaged

DescriptionFile system data is damaged.

AttributeID Event Level Automatically Cleared

0xF00280074 Critical Yes

OceanStor 5300 V3&5500 V3&5600 V3&5800 V3&6800V3 Storage SystemEvent Reference 2 Troubleshooting Events

Issue 04 (2015-06-10) Huawei Proprietary and ConfidentialCopyright © Huawei Technologies Co., Ltd.

189

Impact on the System

Some services will be damaged and some data may lose.

Possible Causes

None.

Procedure

Collect related information and contact technical support engineers.

----End

Related Information

None

2.222 0xF00280075 Write Protection Is Enabled For The FileSystem

Description

Write protection is enabled for the file system.

Attribute

ID Event Level Automatically Cleared

0xF00280075 Critical Yes

Impact on the System

The file can be read only.

Possible Causes

N/A.

Procedure

Collect related information and contact technical support engineers.

----End

OceanStor 5300 V3&5500 V3&5600 V3&5800 V3&6800V3 Storage SystemEvent Reference 2 Troubleshooting Events

Issue 04 (2015-06-10) Huawei Proprietary and ConfidentialCopyright © Huawei Technologies Co., Ltd.

190

Related InformationNone

2.223 0xF00280076 Files Or Directories Are Damaged.

DescriptionFiles or directories are damaged.

Attribute

ID Event Level Automatically Cleared

0xF00280076 Major Yes

Impact on the SystemSome data in the damaged files or directories may lose.

Possible CausesN/A.

Procedure

Collect related information and contact technical support engineers.

----End

Related InformationNone

2.224 0xF000B0102 External LUN Is Changed To CommandDevice

DescriptionExternal LUN is changed to command device.

OceanStor 5300 V3&5500 V3&5600 V3&5800 V3&6800V3 Storage SystemEvent Reference 2 Troubleshooting Events

Issue 04 (2015-06-10) Huawei Proprietary and ConfidentialCopyright © Huawei Technologies Co., Ltd.

191

Attribute

ID Event Level Automatically Cleared

0xF000B0102 Major No

Impact on the System

When reconnecting the physical links related, this LUN can not access.

Possible Causes

The remote LUN related is changed to command device.

Procedure

Step 1 Confirm the reason for this operation of this LUN.

1. If the customer changed this LUN to command device on purpose=>Step 2.

2. If it's a misoperation, change this LUN back to normal LUN=>Step 4.

Step 2 Check whether the LUN is used or not.

1. If the LUN is used, stop dispatching I/O to this LUN and delete the eDevLUNrelated=>Step 3.

2. if the LUN is not used=>Step 3.

Step 3 Unmap this LUN and rescan for remote LUNs=>Step 4.

Step 4 Clear the alarm manually.

----End

Related Information

None

2.225 0xF00D10013 Some Statuses Of A ManagementModule Cannot Be Monitored

Description

Some statuses of a management module cannot be monitored, because internal communicationlinks are faulty. As a result, the system cannot determine whether the management module iscorrectly inserted.

OceanStor 5300 V3&5500 V3&5600 V3&5800 V3&6800V3 Storage SystemEvent Reference 2 Troubleshooting Events

Issue 04 (2015-06-10) Huawei Proprietary and ConfidentialCopyright © Huawei Technologies Co., Ltd.

192

Attribute

ID Event Level Automatically Cleared

0xF00D10013 Major Yes

Impact on the System

l The system cannot monitor some statuses of the management module.

l The system cannot detect whether the management module is correctly inserted.

Possible Causes

l The management module is faulty.

l The controller is faulty.

Procedure

Step 1 Replace the faulty management module. If the alarm persists=>Step 2.

Step 2 Collect related information and contact technical support engineers.

----End

Related Information

None

2.226 0xF00CF004A Some Statuses Of A Controller CannotBe Monitored

Description

Some statuses of a controller cannot be monitored, because internal communication links arefaulty. As a result, the system cannot determine whether the controller is correctly inserted.

Attribute

ID Event Level Automatically Cleared

0xF00CF004A Major Yes

Impact on the System

l Service switchover between controllers is affected.

OceanStor 5300 V3&5500 V3&5600 V3&5800 V3&6800V3 Storage SystemEvent Reference 2 Troubleshooting Events

Issue 04 (2015-06-10) Huawei Proprietary and ConfidentialCopyright © Huawei Technologies Co., Ltd.

193

l The system cannot monitor some statuses of the controller.l The system cannot detect whether the controller is correctly inserted.

Possible Causesl The management module is faulty.l The controller is faulty.

Procedure

Step 1 Replace the faulty controller. If the alarms persist=>Step 2.

Step 2 Collect related information and contact technical support engineers.

----End

Related InformationNone

2.227 0xF01050017 Switch Temperature Is Below The LowerLimit

DescriptionThe temperature of a switch is below the lower limit.

Attribute

ID Event Level Automatically Cleared

0xF01050017 Major Yes

Impact on the SystemThe normal operation of the storage system may be adversely affected.

Possible CausesThe ambient temperature is below the lower limit.

Procedure

Step 1 Check whether the ambient temperature is too low.1. If yes, increase the existing air conditioners temperature or add more air conditioners. If

the alarm persists=>Step 2.2. If no=>Step 2.

OceanStor 5300 V3&5500 V3&5600 V3&5800 V3&6800V3 Storage SystemEvent Reference 2 Troubleshooting Events

Issue 04 (2015-06-10) Huawei Proprietary and ConfidentialCopyright © Huawei Technologies Co., Ltd.

194

Step 2 Collect related information and contact technical support engineers.

----End

Related Information

None

2.228 0xF0105001E Switch Management Network Port IsFaulty

Description

The management network port on a switch is faulty.

Attribute

ID Event Level Automatically Cleared

0xF0105001E Warning Yes

Impact on the System

N/A.

Possible Causes

The management network port is faulty.

Procedure

Collect related information and contact technical support engineers.

----End

Related Information

None

2.229 0xF0105001F Switch Port Is Faulty

Description

A switch port module is faulty.

OceanStor 5300 V3&5500 V3&5600 V3&5800 V3&6800V3 Storage SystemEvent Reference 2 Troubleshooting Events

Issue 04 (2015-06-10) Huawei Proprietary and ConfidentialCopyright © Huawei Technologies Co., Ltd.

195

Attribute

ID Event Level Automatically Cleared

0xF0105001F Major Yes

Impact on the System

N/A.

Possible Causes

The port is faulty.

Procedure

Collect related information and contact technical support engineers.

----End

Related Information

None

2.230 0xF01050022 Switch Port Optical Module Is Faulty

Description

The optical module of a switch port is faulty.

Attribute

ID Event Level Automatically Cleared

0xF01050022 Major Yes

Impact on the System

N/A.

Possible Causes

The optical module is faulty.

OceanStor 5300 V3&5500 V3&5600 V3&5800 V3&6800V3 Storage SystemEvent Reference 2 Troubleshooting Events

Issue 04 (2015-06-10) Huawei Proprietary and ConfidentialCopyright © Huawei Technologies Co., Ltd.

196

Procedure

Step 1 Replace the PCIe cable. If the alarm persists=>Step 2.

Step 2 Collect related information and contact technical support engineers.

----End

Related Information

None

2.231 0xF01050024 Switch Port Negotiated Rate Is SmallerThan The Allowed Maximum

Description

The negotiated rate of a switch port is smaller than the allowed maximum.

Attribute

ID Event Level Automatically Cleared

0xF01050024 Warning Yes

Impact on the System

The interface module where the port resides cannot provide services.

Possible Causes

l The rate of the ports peer port is smaller than that of the port.

l The cable to the port is loose or damaged.

l A port component is faulty.

Procedure

Step 1 Check whether the rate of the ports peer port is smaller than that of the port.

1. If no=>Step 2.

2. If yes=>no further action is required.

Step 2 Check cable connections.

1. Connect the cable correctly to the port. If the alarm persists=>Step 2.2.

2. Replace the cable. If the alarm persists=>Step 3.

Step 3 Replace the modules where the port and its peer port reside. If the alarm persists=>Step 4.

OceanStor 5300 V3&5500 V3&5600 V3&5800 V3&6800V3 Storage SystemEvent Reference 2 Troubleshooting Events

Issue 04 (2015-06-10) Huawei Proprietary and ConfidentialCopyright © Huawei Technologies Co., Ltd.

197

Step 4 Collect related information and contact technical support engineers.

----End

Related InformationNone

2.232 0xF01050025 Switch Optical Module Temperature IsBelow The Lower Limit

DescriptionThe temperature of a switch optical module is below the lower limit.

AttributeID Event Level Automatically Cleared

0xF01050025 Major Yes

Impact on the SystemN/A.

Possible Causesl The ambient temperature is too low.l The optical module is faulty.

Procedure

Step 1 Check whether the ambient temperature is too low.1. If yes, increase the existing air conditioners temperature or add more air conditioners. If

the alarm persists=>Step 2.2. If no=>Step 2.

Step 2 Check whether alarms are generated indicating optical module faults.1. If yes, replace the PCIe cable. If the alarm persists=>Step 3.2. If no=>Step 3.

Step 3 Collect related information and contact technical support engineers.

----End

Related InformationNone

OceanStor 5300 V3&5500 V3&5600 V3&5800 V3&6800V3 Storage SystemEvent Reference 2 Troubleshooting Events

Issue 04 (2015-06-10) Huawei Proprietary and ConfidentialCopyright © Huawei Technologies Co., Ltd.

198

2.233 0xF01050026 Link To A Switch Port Is Abnormal

Description

The link to a switch port is abnormal.

Attribute

ID Event Level Automatically Cleared

0xF01050026 Major Yes

Impact on the System

N/A.

Possible Causes

l Cables are damaged or not firmly inserted into its slot.

l The optical module of the port or that of the ports peer port is faulty.

l The port or its peer port is faulty.

Procedure

Step 1 Check cable connections.

1. Reinsert the cable. If the alarm persists=>Step 1.2.

2. Replace the cable. If the alarm persists=>Step 2.

Step 2 Replace the modules where the port and its peer port reside. If the alarm persists=>Step 3.

Step 3 Collect related information and contact technical support engineers.

----End

Related Information

None

2.234 0xF01050027 Failed To Monitor A Switch OpticalModule

Description

The system failed to monitor a switch optical module.

OceanStor 5300 V3&5500 V3&5600 V3&5800 V3&6800V3 Storage SystemEvent Reference 2 Troubleshooting Events

Issue 04 (2015-06-10) Huawei Proprietary and ConfidentialCopyright © Huawei Technologies Co., Ltd.

199

Attribute

ID Event Level Automatically Cleared

0xF01050027 Major Yes

Impact on the System

N/A.

Possible Causes

l The optical module is faulty.

l The I2C communication is abnormal.

Procedure

Step 1 Check whether alarms are generated indicating optical module faults.

1. If yes, replace the faulty PCIe cable. If the alarm persists=>Step 2.

2. If no=>Step 2.

Step 2 Collect related information and contact technical support engineers.

----End

Related Information

None

2.235 0xF01050029 Switch Optical Module Temperature IsToo High

Description

The temperature of a switch optical module exceeds the upper limit.

Attribute

ID Event Level Automatically Cleared

0xF01050029 Major Yes

Impact on the System

N/A.

OceanStor 5300 V3&5500 V3&5600 V3&5800 V3&6800V3 Storage SystemEvent Reference 2 Troubleshooting Events

Issue 04 (2015-06-10) Huawei Proprietary and ConfidentialCopyright © Huawei Technologies Co., Ltd.

200

Possible Causes

l The heat dissipation system is faulty.

l The optical module is faulty.

Procedure

Step 1 Check whether alarms are generated indicating the overheating of the engine or enclosure thathouses the optical module.

1. If yes, lower the existing air conditioners temperature or add more air conditioners. If thealarm persists=>Step 2.

2. If no=>Step 2.

Step 2 Check whether alarms are generated indicating optical module faults.

1. If yes, replace the faulty PCIe cable. If the alarm persists=>Step 3.

2. If no=>Step 3.

Step 3 Collect related information and contact technical support engineers.

----End

Related Information

None

2.236 0xDA0005 A Member Disk Of A SmartCache Pool GetsA Fault

Description

A member disk of a SmartCache pool gets a fault.

Attribute

ID Event Level Automatically Cleared

0xDA0005 Major Yes

Impact on the System

The I/O performace of LUN and file system accelerated by SmartCache may be compromised.

Possible Causes

l The disk is pulled out.

l The disk gets a fault.

OceanStor 5300 V3&5500 V3&5600 V3&5800 V3&6800V3 Storage SystemEvent Reference 2 Troubleshooting Events

Issue 04 (2015-06-10) Huawei Proprietary and ConfidentialCopyright © Huawei Technologies Co., Ltd.

201

Procedure

Step 1 Check whether the disk is pulled out.1. If yes, insert in the disk which has been pulled out. If the alarm persists after you perform

this operation=>Step 3.2. If no=>Step 2.

Step 2 Check whether the disk gets a fault.1. If yes, replace the faulty disk with a new disk. If the alarm persists after you perform this

operation=>Step 3.2. If no=>Step 3.

Step 3 Collect related information and contact technical support engineers.

----End

Related Information

None

2.237 0x200F406E0013 An Ndmp Backup Task Fails

Description

An NDMP backup task fails.

Attribute

ID Event Level Automatically Cleared

0x200F406E0013 Major No

Impact on the System

N/A.

Possible Causes

l The protected directory cannot be backed up directly.l The file system snapshot fails to be created.l The file system snapshot fails to be deleted.l For example, NetBackup actively stops the backup task; the file system fails to be accessed;

the tape library fails to be accessed.

Procedure

Step 1 Check the network connection.

OceanStor 5300 V3&5500 V3&5600 V3&5800 V3&6800V3 Storage SystemEvent Reference 2 Troubleshooting Events

Issue 04 (2015-06-10) Huawei Proprietary and ConfidentialCopyright © Huawei Technologies Co., Ltd.

202

1. Check whether the network connection is correct.

l If yes=>Step 2.

l If no=>Step 1.2.

2. Reconnect the cables. Then check whether the alarm is cleared.

l If yes=>no further action is required.

l If no=>Step 2.

Step 2 Check the tape library.

1. Ensure that the tape drive is in the up state. Then check whether the alarm is cleared.

l If yes=>no further action is required.

l If no=>Step 2.2.

2. Ensure the tape library is functional. Then check whether the alarm is cleared.

l If yes=>no further action is required.

l If no=>Step 3.

Step 3 Contact technical support engineers.

----End

Related Information

None

2.238 0xF406E0014 An Ndmp Recovery Task Fails

Description

An NDMP recovery task fails.

Attribute

ID Event Level Automatically Cleared

0xF406E0014 Major No

Impact on the System

N/A.

Possible Causes

l The protected directory cannot be used as a recovery directory.

l For example, NetBackup actively stops the recovery task; the file system fails to beaccessed; the tape library fails to be accessed.

OceanStor 5300 V3&5500 V3&5600 V3&5800 V3&6800V3 Storage SystemEvent Reference 2 Troubleshooting Events

Issue 04 (2015-06-10) Huawei Proprietary and ConfidentialCopyright © Huawei Technologies Co., Ltd.

203

Procedure

Step 1 Check the network connection.1. Check whether the network connection is correct.

l If yes=>Step 2.l If no=>Step 1.2.

2. Reconnect the cables. Then check whether the alarm is cleared.l If yes=>no further action is required.l If no=>Step 2.

Step 2 Check the tape library.1. Ensure that the tape drive is in the up state. Then check whether the alarm is cleared.

l If yes=>no further action is required.l If no=>Step 2.2.

2. Ensure the tape library is functional. Then check whether the alarm is cleared.l If yes=>no further action is required.l If no=>Step 3.

Step 3 Contact technical support engineers.

----End

Related InformationNone

2.239 0xF406E0015 Ndmp Authentication Fails, And The IpAddress Of Backup Software Is Locked

DescriptionNDMP authentication fails, and the IP address of backup software is locked.

AttributeID Event Level Automatically Cleared

0xF406E0015 Major Yes

Impact on the SystemN/A.

Possible CausesThe number of NDMP authentication failures has reached the threshold.

OceanStor 5300 V3&5500 V3&5600 V3&5800 V3&6800V3 Storage SystemEvent Reference 2 Troubleshooting Events

Issue 04 (2015-06-10) Huawei Proprietary and ConfidentialCopyright © Huawei Technologies Co., Ltd.

204

Procedure

Wait for the system to automatically unlock the IP address and retry again.

----End

Related Information

None

2.240 0xF00270130 A Remote Replication Fails ToSynchronize Data Automatically

Description

A remote replication fails to synchronize data automatically.

Attribute

ID Event Level Automatically Cleared

0xF00270130 Major No

Impact on the System

N/A.

Possible Causes

l The storage pools are used up.

l Network connectivity is abnormal.

Procedure

Step 1 Check whether alarms are generated indicating storage system faults.

1. If yes, handle the alarms with recommended actions. If synchronization still fails=>Step2.

2. If no, manually start a synchronization. If synchronization still fails=>Step 2.

Step 2 Collect related information and contact technical support engineers.

----End

Related Information

None

OceanStor 5300 V3&5500 V3&5600 V3&5800 V3&6800V3 Storage SystemEvent Reference 2 Troubleshooting Events

Issue 04 (2015-06-10) Huawei Proprietary and ConfidentialCopyright © Huawei Technologies Co., Ltd.

205

2.241 0xF00270112 A Remote Replication Is Unavailable

Description

A remote replication is unavailable.

Attribute

ID Event Level Automatically Cleared

0xF00270112 Critical Yes

Impact on the System

Except deleting the remote replication, other operations related to the remote replication cannotbe performed.

Possible Causes

l When the remote replication is interrupted abnormally, the secondary file system is deletedlocally. As a result, remote replication properties are inconsistent.

l During the startup of the file system remote replication service, metadata fails to be read.

Procedure

Collect related information and contact technical support engineers.

----End

Related Information

None

2.242 0xF00270113 A Remote Replication Is AbnormallyInterrupted

Description

A remote replication is abnormally interrupted.

OceanStor 5300 V3&5500 V3&5600 V3&5800 V3&6800V3 Storage SystemEvent Reference 2 Troubleshooting Events

Issue 04 (2015-06-10) Huawei Proprietary and ConfidentialCopyright © Huawei Technologies Co., Ltd.

206

Attribute

ID Event Level Automatically Cleared

0xF00270113 Major Yes

Impact on the System

Data cannot be backed up correctly.

Possible Causes

l Links are interrupted.

l Links are unstable.

l The secondary file system or the storage pool where the secondary file system resides isfull.

l The service load on the secondary storage system is heavy.

l The primary file system in the remote replication is faulty.

l The secondary file system in the remote replication is faulty.

l The storage pools are faulty.

Procedure

Step 1 Check whether alarms are generated indicating link interruption.

1. If yes, handle the alarms with recommended actions. If the alarms still persist=>Step 2.

2. If no=>Step 2.

Step 2 Check whether links are stable.

1. If yes=>Step 3.

2. If no, ensure that links are stable.

Step 3 Check whether there are alarms about the storage pools where the primary and secondary filesystems reside.

1. If yes, handle the alarms with recommended actions. If the alarms still persist=>Step 4.

2. If no=>Step 4.

Step 4 Collect related information and contact technical support engineers.

----End

Related Information

None

OceanStor 5300 V3&5500 V3&5600 V3&5800 V3&6800V3 Storage SystemEvent Reference 2 Troubleshooting Events

Issue 04 (2015-06-10) Huawei Proprietary and ConfidentialCopyright © Huawei Technologies Co., Ltd.

207

2.243 0xF00CF0056 Only One Cluster Link Is Available

Description

Only one cluster link is available.

Attribute

ID Event Level Automatically Cleared

0xF00CF0056 Warning Yes

Impact on the System

The faulty node has only one link available. If you do not resolve the problem promptly, thecontroller will go offline as soon as the last available link is interrupted.

Possible Causes

l The optical fiber is faulty.

l The optical module is faulty.

l The cable is not connected securely.

l The cluster link is faulty.

Procedure

Step 1 Check whether the physical link is normal.

1. If no, please repair it. If the alarm persists=>Step 2.

2. If yes=>Step 2.

Step 2 Collect related information and contact technical support engineers.

----End

Related Information

None

2.244 0xF000A0084 The Disk Is Rejected By The System

Description

The disk is from other engine.

OceanStor 5300 V3&5500 V3&5600 V3&5800 V3&6800V3 Storage SystemEvent Reference 2 Troubleshooting Events

Issue 04 (2015-06-10) Huawei Proprietary and ConfidentialCopyright © Huawei Technologies Co., Ltd.

208

AttributeID Event Level Automatically Cleared

0xF000A0084 Major Yes

Impact on the SystemThe disk cannot be detected by the storage system.

Possible CausesThe disk is from other engine.

Procedure

Collect related information and contact technical support engineers.

----End

Related InformationNone

2.245 0x1FFFFFFFFFFFFFFC Testing The Alarm Function

DescriptionSimulating the reporting of a fault alarm.

AttributeID Event Level Automatically Cleared

0x1FFFFFFFFFFFFFFC Critical No

Impact on the SystemThis alarm is a simulated one to test the alarm function of the device.

Possible CausesThe alarm function of the device is being tested.

Procedure

OceanStor 5300 V3&5500 V3&5600 V3&5800 V3&6800V3 Storage SystemEvent Reference 2 Troubleshooting Events

Issue 04 (2015-06-10) Huawei Proprietary and ConfidentialCopyright © Huawei Technologies Co., Ltd.

209

This alarm is simulated to test the alarm function of the device. Manually clear the alarm afterthe test.

----End

Related Information

None

2.246 0xF00C9013D IP Address Conflict

Description

IP address conflict.

Attribute

ID Event Level Automatically Cleared

0xF00C9013D Major Yes

Impact on the System

It may cause net invalid.

Possible Causes

N/A.

Procedure

Modify the conflicting IP address.

----End

Related Information

None

2.247 0xF010D0032 The Management Module Firmware IsIncompatible With Storage Array Software

Description

The firmware version of a management module is incompatible with storage array software.

OceanStor 5300 V3&5500 V3&5600 V3&5800 V3&6800V3 Storage SystemEvent Reference 2 Troubleshooting Events

Issue 04 (2015-06-10) Huawei Proprietary and ConfidentialCopyright © Huawei Technologies Co., Ltd.

210

Attribute

ID Event Level Automatically Cleared

0xF010D0032 Major Yes

Impact on the SystemThe management module firmware is incompatible with storage array software.

Possible CausesThe firmware version of the management module is incompatible with storage array software.

Procedure

Collect related information and contact technical support engineers.

----End

Related InformationNone

2.248 0xF01060060 Cache Partition Failed To ProcessReceived I/O

DescriptionThe I/O is beyond maximum I/O grain size of the Cache partition and can not be handled. Thebusiness may be interrupted.

Attribute

ID Event Level Automatically Cleared

0xF01060060 Critical No

Impact on the SystemI/O error, and business might be interrupted.

Possible CausesThe size of I/O from host is beyond maximum I/O grain size of the Cache partition.

OceanStor 5300 V3&5500 V3&5600 V3&5800 V3&6800V3 Storage SystemEvent Reference 2 Troubleshooting Events

Issue 04 (2015-06-10) Huawei Proprietary and ConfidentialCopyright © Huawei Technologies Co., Ltd.

211

Procedure

Please modify the Cache partition size at least to 512MB.

----End

Related Information

None

2.249 0x100F01060063 Controller Is Overloaded

Description

CPU or memory resource usage of a controller has exceeded the overload threshold, and thecontroller enters the overloaded state.

Attribute

ID Event Level Automatically Cleared

0x100F01060063 Warning Yes

Impact on the System

The controller starts overload protection to reduce the number of front-end I/Os in a time unit,which may increase the I/O latency.

Possible Causes

The workload on the controller is too heavy.

Procedure

Reduce services carried by the controller or expand the system. For details, contact technicalsupport engineers.

----End

Related Information

None

OceanStor 5300 V3&5500 V3&5600 V3&5800 V3&6800V3 Storage SystemEvent Reference 2 Troubleshooting Events

Issue 04 (2015-06-10) Huawei Proprietary and ConfidentialCopyright © Huawei Technologies Co., Ltd.

212

2.250 0xF00D00017 Failed To Synchronize The FirmwareVersion Of An Expansion Module

Description

The firmware version fails to be synchronized after an expansion module is inserted.

Attribute

ID Event Level Automatically Cleared

0xF00D00017 Major Yes

Impact on the System

Ports on the expansion module are isolated.

Possible Causes

l The cable is faulty or not securely connected.

l The interface module is removed or faulty.

l The expansion module is faulty.

Procedure

Step 1 Check whether the cable is removed or damaged.

1. If the cable is removed, reinsert it. If the alarm persists=>Step 1.2.

2. Replace the cable with an intact one. If the alarm persists=>Step 2.

Step 2 Check whether the interface module is removed or damaged.

1. If the interface module is removed, reinsert it. If the alarm persists=>Step 2.2.

2. Replace the interface module. If the alarm persists=>Step 3.

Step 3 Collect related event information and contact technical support engineers.

----End

Related Information

None

OceanStor 5300 V3&5500 V3&5600 V3&5800 V3&6800V3 Storage SystemEvent Reference 2 Troubleshooting Events

Issue 04 (2015-06-10) Huawei Proprietary and ConfidentialCopyright © Huawei Technologies Co., Ltd.

213

2.251 0xF00CF0059 Heartbeat Connection Between AController And A Management Module Is Interrupted

DescriptionThe heartbeat connection between a controller and a management module is interrupted, so thecontroller cannot access the management module.

Attribute

ID Event Level Automatically Cleared

0xF00CF0059 Major Yes

Impact on the SystemThe controller cannot access the management module.

Possible Causesl The management module is faulty.l The controller is faulty.

Procedure

Step 1 Check whether alarms are generated indicating management module faults.1. If yes, replace the faulty management module.If the alarm persists=>Step 2.2. If no=>Step 2.

Step 2 Replace the controller.If alarm persists=>Step 3.

Step 3 Collect related information and contact technical support engineers.

----End

Related InformationNone

2.252 0xF00270137 Remote Replication Is AutomaticallySplit

DescriptionRemote replication is automatically split.

OceanStor 5300 V3&5500 V3&5600 V3&5800 V3&6800V3 Storage SystemEvent Reference 2 Troubleshooting Events

Issue 04 (2015-06-10) Huawei Proprietary and ConfidentialCopyright © Huawei Technologies Co., Ltd.

214

Attribute

ID Event Level Automatically Cleared

0xF00270137 Warning Yes

Impact on the System

The remote replication is not synchronized automatically. It must be manually synchronizedafter storage pool expansion.

Possible Causes

The capacity of the storage pool that houses the primary LUN or secondary LUN of the remotereplication is insufficient.

Procedure

Step 1 Check whether the capacity of the storage pool that houses the primary LUN or secondary LUNof the remote replication is insufficient.

1. If yes, expand the capacity of the storage pool and manually synchronize the remotereplication.

2. If no=>Step 2.

Step 2 Collect related information and contact technical support engineers.

----End

Related Information

None

2.253 0xF0DD0004 Remote Replication Consistency GroupIs Automatically Split

Description

Remote replication consistency group is automatically split.

Attribute

ID Event Level Automatically Cleared

0xF0DD0004 Warning Yes

OceanStor 5300 V3&5500 V3&5600 V3&5800 V3&6800V3 Storage SystemEvent Reference 2 Troubleshooting Events

Issue 04 (2015-06-10) Huawei Proprietary and ConfidentialCopyright © Huawei Technologies Co., Ltd.

215

Impact on the System

The remote replication consistency group is not synchronized automatically. It must be manuallysynchronized after storage pool expansion.

Possible Causes

The capacity of the storage pool that houses the primary LUN or secondary LUN of a remotereplication pair in the consistency group is insufficient.

Procedure

Step 1 Check whether the capacity of the storage pool that houses the primary LUN or secondary LUNof a remote replication pair in the consistency group is insufficient.

1. If yes, expand the capacity of the storage pool and manually synchronize the remotereplication consistency group.

2. If no=>Step 2.

Step 2 Collect related information and contact technical support engineers.

----End

Related Information

None

2.254 0xF40020005 Number Of NAS Client Connections OfA Controller Reaches The Upper Limit

Description

The number of NAS client connections of a controller reaches the upper limit.

Attribute

ID Event Level Automatically Cleared

0xF40020005 Major Yes

Impact on the System

New connections cannot be connected to the controller, causing NAS client exceptions.

Possible Causes

The number of TCP connections reaches the upper limit.

OceanStor 5300 V3&5500 V3&5600 V3&5800 V3&6800V3 Storage SystemEvent Reference 2 Troubleshooting Events

Issue 04 (2015-06-10) Huawei Proprietary and ConfidentialCopyright © Huawei Technologies Co., Ltd.

216

Procedure

Relocate some services running on the controller to other controllers or reduce the number ofNAS client connections.

----End

Related Information

None

2.255 0xF00D80119 Storage Pool Remaining Capacity IsInsufficient

Description

The used capacity of a storage pool reachs the threshold.

Attribute

ID Event Level Automatically Cleared

0xF00D80119 Major Yes

Impact on the System

N/A.

Possible Causes

The used capacity of the storage pool reachs the threshold.

Procedure

Step 1 Expand the capacity of the storage pool. If the alarm persists=>Step 2.

Step 2 Collect related information and contact technical support engineers.

----End

Related Information

None

OceanStor 5300 V3&5500 V3&5600 V3&5800 V3&6800V3 Storage SystemEvent Reference 2 Troubleshooting Events

Issue 04 (2015-06-10) Huawei Proprietary and ConfidentialCopyright © Huawei Technologies Co., Ltd.

217

2.256 0xF00D80120 Storage Pool Capacity Is About To BeUsed Up

Description

The storage pool capacity is about to be used up, which may cause service interruption on thispool.

Attribute

ID Event Level Automatically Cleared

0xF00D80120 Critical Yes

Impact on the System

which may cause service interruption on this pool.

Possible Causes

The storage pool capacity is about to be used up.

Procedure

Step 1 Expand the capacity of the storage pool. If the alarm persists=>Step 2.

Step 2 Collect related information and contact technical support engineers.

----End

Related Information

None

2.257 0xF01060043 Failed To Reach The Control ObjectiveOf SmartQoS

Description

Failed to reach the control objective of SmartQoS by all means. Please confirm the rationalityof configuration.

OceanStor 5300 V3&5500 V3&5600 V3&5800 V3&6800V3 Storage SystemEvent Reference 2 Troubleshooting Events

Issue 04 (2015-06-10) Huawei Proprietary and ConfidentialCopyright © Huawei Technologies Co., Ltd.

218

Attribute

ID Event Level Automatically Cleared

0xF01060043 Major No

Impact on the System

The whole performance would be declined.

Possible Causes

The business pressure of the LUN in the SmartQoS is not enough, but the control objective isconfigured too high.

Procedure

Please confirm the business pressure of the LUN in the SmartQoS policy. Deactivate the policyand modify the control objective, then activate the policy again.

----End

Related Information

None

2.258 0xF40020006 Number Of File Information Items To BeBacked Up Reaches The Upper Limit

Description

When the failover function is used, the controller backs up file information. The number of fileinformation items reaches the upper limit.

Attribute

ID Event Level Automatically Cleared

0xF40020006 Major Yes

Impact on the System

New file information cannot be backed up. If the failover function is used, service switchovermay fail.

OceanStor 5300 V3&5500 V3&5600 V3&5800 V3&6800V3 Storage SystemEvent Reference 2 Troubleshooting Events

Issue 04 (2015-06-10) Huawei Proprietary and ConfidentialCopyright © Huawei Technologies Co., Ltd.

219

Possible Causes

The number of file information items to be backed up for the failover function reaches the upperlimit.

Procedure

Step 1 Migrate some services to other controllers. If the alarm persists=>Step 2.

Step 2 Collect related information and contact technical support engineers.

----End

Related Information

None

2.259 0xF40440017 Controller Is Disconnected From AnLDAP/NIS Server

Description

A controller is disconnected from an LDAP/NIS server.

Attribute

ID Event Level Automatically Cleared

0xF40440017 Major Yes

Impact on the System

LDAP/NIS authentication fails. NFS services are affected, and the data cannot be accessednormally.

Possible Causes

l The LDAP/NIS server is shut down.

l The device is incorrectly communicating with the LDAP/NIS server.

Procedure

Step 1 Check the status of the LDAP/NIS server.

1. Check whether the LDAP/NIS server is started.

l If yes=>Step 2.

l If no=>Step 1.2.

OceanStor 5300 V3&5500 V3&5600 V3&5800 V3&6800V3 Storage SystemEvent Reference 2 Troubleshooting Events

Issue 04 (2015-06-10) Huawei Proprietary and ConfidentialCopyright © Huawei Technologies Co., Ltd.

220

2. Start the LDAP/NIS server. Then check whether the alarm is cleared.

l If yes=>no further action is required.

l If no=>Step 2.

Step 2 Check the network connectivity between the device and LDAP/NIS server.

1. Check whether the device is correctly communicating with the LDAP/NIS server.

l If yes=>Step 3.

l If no=>Step 2.2.

2. Contact the network administrator to rectify the network fault. Then check whether thealarm is cleared.

l If yes=>no further action is required.

l If no=>Step 3.

Step 3 Collect related information and contact technical support engineers.

----End

Related Information

None

2.260 0x100F03300072 Failed To Restore A Virtual Machine

Description

Failed to restore a virtual machine.

Attribute

ID Event Level Automatically Cleared

0x100F03300072 Warning Yes

Impact on the System

Failed to restore the virtual machine's operating status.

Possible Causes

l The virtual machine status is abnormal.

l The container does not have sufficient resources.

Procedure

OceanStor 5300 V3&5500 V3&5600 V3&5800 V3&6800V3 Storage SystemEvent Reference 2 Troubleshooting Events

Issue 04 (2015-06-10) Huawei Proprietary and ConfidentialCopyright © Huawei Technologies Co., Ltd.

221

Check and power on the virtual machine manually.

----End

Related Information

None

2.261 0x100F03300073 Failed To Shut Down A VirtualMachine

Description

Failed to shut down a virtual machine.

Attribute

ID Event Level Automatically Cleared

0x100F03300073 Warning Yes

Impact on the System

Some virtual machine data may be lost.

Possible Causes

The virtual machine is running under a heavy service load and is not powered off correctly.

Procedure

Step 1 Check whether the virtual machine can be correctly powered on when the controller is workingcorrectly.

To repair a damaged virtual machine, contact technical support engineers.

----End

Related Information

None

2.262 0x100F03300074 Incomplete Virtual Machine Creation

Description

The creation of a virtual machine is incomplete.

OceanStor 5300 V3&5500 V3&5600 V3&5800 V3&6800V3 Storage SystemEvent Reference 2 Troubleshooting Events

Issue 04 (2015-06-10) Huawei Proprietary and ConfidentialCopyright © Huawei Technologies Co., Ltd.

222

Attribute

ID Event Level Automatically Cleared

0x100F03300074 Warning Yes

Impact on the System

The virtual machine is unavailable.

Possible Causes

The controller is powered off during virtual machine creation.

Procedure

Delete the virtual machine and create it using the original template.

----End

Related Information

None

2.263 0xF00280112 Number Of Files In A File System IsAbout To Exceed The Upper Limit

Description

The number of files in a file system is about to exceed the upper limit.

Attribute

ID Event Level Automatically Cleared

0xF00280112 Major Yes

Impact on the System

File system performance may deteriorate.

Possible Causes

The number of files in the file system is about to exceed the upper limit.

OceanStor 5300 V3&5500 V3&5600 V3&5800 V3&6800V3 Storage SystemEvent Reference 2 Troubleshooting Events

Issue 04 (2015-06-10) Huawei Proprietary and ConfidentialCopyright © Huawei Technologies Co., Ltd.

223

Procedure

Step 1 Stop writing new files into the file system.

Step 2 Delete unnecessary files from the file system.

----End

Related Information

None

2.264 0xF00280113 Number Of Files In A Directory Of A FileSystem Is About To Exceed The Upper Limit

Description

The number of files in a directory of a file system is about to exceed the upper limit.

Attribute

ID Event Level Automatically Cleared

0xF00280113 Major Yes

Impact on the System

Directory read performance deteriorates.

Possible Causes

The number of files in the directory of the file system is about to exceed the upper limit.

Procedure

Step 1 Stop writing new files into the directory.

Step 2 Delete unnecessary files from the directory.

----End

Related Information

None

OceanStor 5300 V3&5500 V3&5600 V3&5800 V3&6800V3 Storage SystemEvent Reference 2 Troubleshooting Events

Issue 04 (2015-06-10) Huawei Proprietary and ConfidentialCopyright © Huawei Technologies Co., Ltd.

224

2.265 0xF00CF005C Number Of Opened Files On AController Is About To Exceed The Upper Limit

DescriptionThe number of opened files on a controller is about to exceed the upper limit.

Attribute

ID Event Level Automatically Cleared

0xF00CF005C Major Yes

Impact on the SystemFiles fail to be opened, and services are interrupted.

Possible CausesThe number of opened files on the controller is about to exceed the upper limit.

Procedure

Close the opened files on the controller.

----End

Related InformationNone

OceanStor 5300 V3&5500 V3&5600 V3&5800 V3&6800V3 Storage SystemEvent Reference 2 Troubleshooting Events

Issue 04 (2015-06-10) Huawei Proprietary and ConfidentialCopyright © Huawei Technologies Co., Ltd.

225

A How to Obtain Help

If a tough or critical problem persists in routine maintenance or troubleshooting, contact Huaweifor technical support.

A.1 Preparations For Contacting HuaweiTo better solve the problem, you need to collect troubleshooting information and makedebugging preparations before contacting Huawei.

A.2 How to Use the DocumentHuawei provides guide documents shipped with the device. The guide documents can be usedto handle the common problems occurring in daily maintenance or troubleshooting.

A.3 How to Obtain Help from WebsiteHuawei provides users with timely and efficient technical support through the regional offices,secondary technical support system, telephone technical support, remote technical support, andonsite technical support.

A.4 Ways to Contact HuaweiHuawei Technologies Co., Ltd. provides customers with comprehensive technical support andservice. For any assistance, contact our local office or company headquarters.

OceanStor 5300 V3&5500 V3&5600 V3&5800 V3&6800V3 Storage SystemEvent Reference A How to Obtain Help

Issue 04 (2015-06-10) Huawei Proprietary and ConfidentialCopyright © Huawei Technologies Co., Ltd.

226

A.1 Preparations For Contacting HuaweiTo better solve the problem, you need to collect troubleshooting information and makedebugging preparations before contacting Huawei.

A.1.1 Collecting Troubleshooting InformationYou need to collect troubleshooting information before troubleshoot.

You need to collect the following information:l Name and address of the customerl Contact person and telephone numberl Time when the fault occurredl Description of the fault phenomenal Device type and software versionl Measures taken after the fault occurs and the related resultsl Troubleshooting level and required solution deadline

A.1.2 Making Debugging PreparationsWhen you contact Huawei for help, the technical support engineer of Huawei might assist youto do certain operations to collect information about the fault or rectify the fault directly.

Before contacting Huawei for help, you need to prepare the boards, port modules, screwdrivers,screws, cables for serial ports, network cables, and other required materials.

A.2 How to Use the DocumentHuawei provides guide documents shipped with the device. The guide documents can be usedto handle the common problems occurring in daily maintenance or troubleshooting.

To better solve the problems, use the documents before you contact Huawei for technical support.

A.3 How to Obtain Help from WebsiteHuawei provides users with timely and efficient technical support through the regional offices,secondary technical support system, telephone technical support, remote technical support, andonsite technical support.

Contents of the Huawei technical support system are as follows:l Huawei headquarters technical support departmentl Regional office technical support centerl Customer service centerl Technical support website: http://support.huawei.com/enterprise/

You can query how to contact the regional offices at http://support.huawei.com/enterprise/.

OceanStor 5300 V3&5500 V3&5600 V3&5800 V3&6800V3 Storage SystemEvent Reference A How to Obtain Help

Issue 04 (2015-06-10) Huawei Proprietary and ConfidentialCopyright © Huawei Technologies Co., Ltd.

227

A.4 Ways to Contact HuaweiHuawei Technologies Co., Ltd. provides customers with comprehensive technical support andservice. For any assistance, contact our local office or company headquarters.

Huawei Technologies Co., Ltd.

Address: Huawei Industrial Base Bantian, Longgang Shenzhen 518129 People's Republic ofChina

Website: http://enterprise.huawei.com/

OceanStor 5300 V3&5500 V3&5600 V3&5800 V3&6800V3 Storage SystemEvent Reference A How to Obtain Help

Issue 04 (2015-06-10) Huawei Proprietary and ConfidentialCopyright © Huawei Technologies Co., Ltd.

228

B Glossary

A

AC power module The module that transfers the external AC power supply into the powersupply for internal use.

Applicationserver

A service processing node (a computer device) in the network.Application programs of data services are run on the application server.

Asynchronousremotereplication

A kind of remote replication. When the data on the primary site isupdated, the data does not need to be updated on the mirroring sitesynchronously to finish the update. In this way, performance is notreduced due to data mirroring.

B

Backup A periodic operation performed on the data stored in the database forthe purposes of database recovery in case that the database is faulty. Thebackup also refers to data synchronization between active and standbyboards.

Bandwidth A range of transmission frequencies a transmission line or channel cancarry in a network. In fact, the bandwidth is the difference between thehighest and lowest frequencies in the transmission line or channel. Thegreater the bandwidth, the faster the data transfer rate.

Baud rate The number of times per second the signal can change on a transmissionline. Commonly, the transmission line uses only two signal states,making the baud rate equal to the number of bits per second that can betransferred. The underlying transmission technique may use some of thebandwidth, so it may not be the case that user data transfers at the line'sspecified bit rate.

Bit error An incompatibility between a bit in a transmitted digital signal and thecorresponding bit in the received digital signal.

Bit error rate The percentage of bits that have errors relative to the total number ofbits received in a transmission.

OceanStor 5300 V3&5500 V3&5600 V3&5800 V3&6800V3 Storage SystemEvent Reference B Glossary

Issue 04 (2015-06-10) Huawei Proprietary and ConfidentialCopyright © Huawei Technologies Co., Ltd.

229

Bonding Bonding can bind multiple independent physical network ports into alogical port, which ensures the high availability of server networkconnections and improving network performance.

Boundary scan A test methodology that uses shift registers in the output connections ofintegrated circuits. One IC often is connected to the next. A data patternis passed through the chain and the observed returned data streamaffected by the circuit conditions gives an indication of any faultspresent. The system is defined under IEEE standard 1149.1 and is alsooften known as JTAG (Joint Test Action Group).

Browser/Server An architecture that defines the roles of browser and server, where thebrowser is the service request party and the server is the service provider.

C

Cache hit ratio The ratio of directly accessed I/O from Cache to all the I/O operationduring the read operation.

Cache prefetchstrategy

According to the operation in which data has been read or is being read,the required data is read from a disk into the cache in advance.

Captive Screw After the screw is loosened, screw caps and bolts are not disconnectedfrom the main body.

Cascading Connect the storage system to more disk enclosures through connectioncables, thus expanding the capacity of the storage system.

CHAP A method to periodically verify the identity of the peer using a 3-wayhandshake. During the establishment of a link, the authenticator sendsa "challenge" message to the peer. The peer responds with a valuecalculated using a "one-way hash" function. The authenticator checksthe response against its own calculation of the expected hash value. Ifthe values match, the authentication is acknowledged. CHAP providesprotection against playback attack.

Clone A snapshot technology. The source data is completely copied togenerate a data duplicate; therefore the duplicate needs the storage spaceas the same size as the source data. It is also called clone. In the VISsystem, it is also called third-mirror break-off snapshot.

Cluster A mechanism adopted to improve the system performance. Severaldevices of the same type form a cluster. The exterior of a cluster is somelike a kind of equipment. In the interior of a cluster, the nodes share theload.

Coffer A technology for ensuring data security and integrity in a storagesystem. It is used to store the mission-critical data of the system.

Coffer disk Disks that build up the coffer.

Command device A special LUN through which the host can send inband commands tostorage devices.

OceanStor 5300 V3&5500 V3&5600 V3&5800 V3&6800V3 Storage SystemEvent Reference B Glossary

Issue 04 (2015-06-10) Huawei Proprietary and ConfidentialCopyright © Huawei Technologies Co., Ltd.

230

Constant prefetch A cache prefetch strategy. The size of the data to be prefetched is thesize as set. This strategy applies to the applications that require readingdata of a fixed size in a certain order. An example is the streaming mediademanded by multiple subscribers who use the same bit rate.

Controller The core module that processes services in a storage system. It containsphysical components such as system-level CPUs and memory.

Controllerenclosure

An enclosure that accommodates controllers and provides storageservices. It is the core component of a storage system, and generallyconsists of components such as controllers, power supplies, and fans.

Copyback The process of copying the data from the hot spare disk back to theprevious disk when the faulty member disk is restored or replaced by anew one.

Copying A state of pair. The state indicates that the source LUN data is beingsynchronized to the target LUN.

D

Data compression Encoding data to take up less storage space and less bandwidth fortransmission.

Datadeduplication

A specialized data compression technique for eliminating coarse-grained redundant data, typically to improve storage utilization. In thededuplication process, duplicate data is deleted, leaving only one copyof the data to be stored, along with references to the unique copy of data.Deduplication is able to reduce the required storage capacity since onlythe unique data is stored.

Data flow A process that involves processing the data extracted from the sourcesystem, such as filtering, integration, calculation, and summary, findingand solving data inconsistency, and deleting invalid data so that theprocessed data meets the requirements of the destination system for theinput data.

Data migration It is the process to cleanse and transform history data, and then loadthem to the new system.

Data source A system, database, or file that can make BOs persistent. A data sourcecan be a database instance or a database user.

Data switch A data switch used for interconnections between controllers.

Dirty data The data that is stored temporarily on cache and has not been writtenonto disks.

OceanStor 5300 V3&5500 V3&5600 V3&5800 V3&6800V3 Storage SystemEvent Reference B Glossary

Issue 04 (2015-06-10) Huawei Proprietary and ConfidentialCopyright © Huawei Technologies Co., Ltd.

231

Disaster recovery A system deployment solution aiming at reducing loss in disasters. Aset of disaster recovery system that is the same as the production systemis deployed as a backup to store the production data when a fault occursin the production system. The applications are switched over to thedisaster recovery system before the production system recovers. Afterthe production system recovers, the applications are switched back tothe production system.

Disk array A set of disks from one or more commonly accessible disk subsystem.These disks are combined and controlled by the control software. Thecontrol software provides the storage capacity of these disks for hostsas one or more virtual disks.

Disk Domain A combination of disks. A disk domain consists of the same type ordifferent types of disks. Disk domains are isolated from each other.Therefore, services carried by different disk domains do not affect eachother in terms of performance and faults (if any).

Disk location The process of locating a hard disk, that is, determining the enclosureID and slot ID of the hard disk in the storage system.

Disk enclosure It consists of the following parts in redundancy: expansion module, harddisk, power module, and fan module. System capacity can be expandedby cascading multiple disk enclosures.

Disk utilization The percentage of used capacity in the total available capacity.

E

eDevLUN(external deviceLUN)

Logic space created by third-party storage systems.

Engine Two controllers in one enclosure are called Engine.

Expansion Connecting a storage system to more disk enclosures throughconnection cables, thus expanding the capacity of the storage system.

Expander module A component used for expanding.

F

Failover The automatic substitution of a functionally equivalent systemcomponent for a failed one. The term failover is most often applied tointelligent controllers connected to the same storage devices and hostcomputers. If one of the controllers fails, failover occurs, and thesurvivor takes over its I/O load.

OceanStor 5300 V3&5500 V3&5600 V3&5800 V3&6800V3 Storage SystemEvent Reference B Glossary

Issue 04 (2015-06-10) Huawei Proprietary and ConfidentialCopyright © Huawei Technologies Co., Ltd.

232

Field replaceableunit

A unit that can function as a circuit board, part, or component of anelectronic device. It can be quickly and easily removed from a personalcomputer or other electronic devices. If an FRU becomes faulty, userscan replace it with a new one instead of sending the entire product orsystem for maintenance.

File Engine The component in a unified storage systems that provides file-levelservice.

Firmware The programmable software part in a hardware component. A firmwareis a part of hardware, but is scalable as software.

Front-end hostport

The port that connects the controller enclosure to the service side andtransfers service data. There are three types of front-end host ports: SAS,FC, and iSCSI.

G

Gateway The entrance node on another network.

Global system formobilecommunications

The second-generation mobile networking standard defined byEuropean Telecommunications Standards Institute (ETSI). It is aimedat designing a standard for global mobile phone networks. The standardallows a subscriber to use a phone globally. GSM consists of three mainparts: mobile switching subsystem (MSS), base station subsystem(BSS), and mobile station (MS).

H

Hard disk A non-volatile storage device that stores digitally encoded data onrapidly rotating platters with magnetic surfaces. Hard disks generallyoffer more storage and quicker access to data than floppy disks do.

Hard disk tray The tray that bears the hard disk.

Hard quota The value to limit the space used in quota configuration. If the spaceused arrives hard quota, file operation is not allowed to continue.

Heartbeat Heartbeats are the packets, requiring no acknowledgement, transmittedbetween two devices. The device can judge the validity status of thepeer device. Heartbeat supports node communication, fault diagnosis,and event triggering.

Hit ratio The ratio of directly accessed I/Os from cache to all I/Os.

Hot swap In a running system, inserting or removing a blade does not affectnormal running of the system.

I

OceanStor 5300 V3&5500 V3&5600 V3&5800 V3&6800V3 Storage SystemEvent Reference B Glossary

Issue 04 (2015-06-10) Huawei Proprietary and ConfidentialCopyright © Huawei Technologies Co., Ltd.

233

I/O Data movement process between memory and peripheral devices in thecomputer system. I/O is a collective name, indicating the operationsreading data into the memory and writing data to other places fromcomputer memory.

Inbandmanagement

Inband management means that the management control information ofthe network and the carrier service information of the user network aretransferred through the same logical channel. Inband managementenables users to manage storage arrays through commands.Management commands are sent through service channels, that is, I/Owrite and read channels. The advantages of inband management includehigh speed, stable transfer, and no additional management network portsrequired.

Initiator A system component that can initiate an I/O operation on an I/O bus oron a network.

Intelligentprefetch

A cache prefetch strategy. The system software calculates a proper sizeof prefetched data. This strategy applies to a read application involvinga single bit stream or to the situations where you do not know whetherthe data is read in a certain order. An example is reading or writing afile.

Interface module interface module connects various types of front-end host port, such asthe front-end host ports of SAS, FC and iSCSI.The interface module can be configured with one type of the followinghost ports or expansion ports: 10Gb iSCSI, 8Gb FC, and iSCSI hostports, or 4Gb FC and 6Gb SAS expansion ports.

L

Load balance A method of adjusting the system, application components and data toaveragely distribute the applied I/O or computing requests for physicalresources of the system.

Logical unit The entity is located inside the SCSI object, and can execute I/Ocommands. After a SCSI I/O command is sent to an object, the logicunit inside the object executes this command. Usually, each SCSIphysical disk has one logic unit. A tape drive and array controller mayhave multiple logic units, which process different I/O commands. Eachlogic unit inside an array controller corresponds to a virtual disk.

Logical unitnumber

The SCSI identifier of the internal logical unit of a target.

LUN format The process of writing 0 bits in the data area on the logical drive andgenerating related parity bits so that the logical drive can be in the readystate.

LUN mapping The storage system maps LUNs to ASs so that the ASs can access thestorage reorganization.

OceanStor 5300 V3&5500 V3&5600 V3&5800 V3&6800V3 Storage SystemEvent Reference B Glossary

Issue 04 (2015-06-10) Huawei Proprietary and ConfidentialCopyright © Huawei Technologies Co., Ltd.

234

LUN migration A method for the data in the LUN to migrate between different physicalstorage space while ensuring data integrity and uninterrupted operationhost services.

LUN copy The function of copying the original LUN data to one or multiple targetLUNs.

M

Maintenanceterminal

The computer that is connected through a serial port or managementnetwork port and maintains the storage system.

Managementnetwork

An entity that provides a means to transmit and process the informationrelated to network management.

Managementnetwork port

The network port on the controller enclosure that is connected to themaintenance terminal. It is provided for the remote maintenanceterminal.

N

Node A managed device in the network. For a device with a single frame, onenode stands for one device. For a device with multiple frames, one nodestands for one frame of the device.

O

Out-of-bandmanagement

A management mode used during out-of-band networking. In the out-of-band management mode, the management and control informationof the network and the bearer service information of the user networkare transmitted through different logical channels.

Original LUN The LUN where the original data of the copied LUNs is located.

Owningcontroller

For a LUN or file system, the user configures the owing controller, thatis, specified the created LUN or file system to a certain controller. Whenthe owning controller of the LUN or file system is invalid, anothercontroller manages the LUN or file system automatically. When theowning controller of the LUN or file system is restored, the originalcontroller manages the LUN or file system again.

P

Power failureprotection

When the external power failure occurs, the AC PEM depends on thebattery for power supply, which ensures the integrity of the dirty datain cache.

OceanStor 5300 V3&5500 V3&5600 V3&5800 V3&6800V3 Storage SystemEvent Reference B Glossary

Issue 04 (2015-06-10) Huawei Proprietary and ConfidentialCopyright © Huawei Technologies Co., Ltd.

235

Pre-copy When the system monitors that a member disk in a RAID group is tofail, the system copies the data on the disk to a hot spare disk in advance.This technology is called pre-copy.

Primary storagecontroller

The controller that plays a leading role in controlling the managementis the primary storage controller. It can perform relevant managementoperations on the controller enclosure.

Primary/Secondaryswitchover

A procedure during which the two controllers of the storage systemchange their master/slave states.

Prior controller For the application server LUN, prior controller means that the workingcontroller is the owner controller of the corresponding array LUN.

Q

Quota tree A first-level directory of file system that can be managed with quota.

R

RAID level The application of different redundant types to a logical drive. A RAIDlevel improves the fault tolerance or performance of the logical drivebut reduces the available capacity of the logical drive. You must specifya RAID level for each logical drive.

Reconstruction A function of the storage system. It refers to the process of restoring thedata saved in the faulty member disk in a storage pool.

Redundancy The scheme to add more than one channels, elements or parts that havethe same functions with the counterparts in the system or device at acritical place. When a fault occurs, the system or device can work well,and the reliability is then improved.

Remotereplication

A core technology for disaster recovery and a foundation thatimplements remote data synchronization and disaster recovery. Thistechnology remotely maintains a set of data mirror through the remotedata connection function of the storage devices that are separated indifferent places. Even when a disaster occurs, the data backup on theremote storage device is not affected. Remote replication can be dividedinto synchronous remote replication and asynchronous remotereplication by whether the host that requires mirrors needs theconfirmation information of the remote replication site.

Reversesynchronizing

The process of restoring data from the redundancy machine (RM) whenthe services of the production machine (PM) are recovering.

Route The path that network traffic takes from its source to its destination. Ina TCP/IP network, each IP packet is routed independently. Routes canchange dynamically.

OceanStor 5300 V3&5500 V3&5600 V3&5800 V3&6800V3 Storage SystemEvent Reference B Glossary

Issue 04 (2015-06-10) Huawei Proprietary and ConfidentialCopyright © Huawei Technologies Co., Ltd.

236

S

Script A collection of data statements used to perform an operation.

Secondarycontroller

(1) A controller that backs up service and management data of theprimary controller in a clustered system. When the primary controllerfails, the secondary controller is upgraded to the primary controller andtakes over the management and services of the controller enclosure. (2)A controller that backs up the management data of the primary controllerin a block-level array. When the primary controller fails, the secondarycontroller is upgraded to the primary controller and takes over themanagement of the system.

Serial port An input/output location (channel) that sends and receives data to andfrom a computer's CPU or a communications device one bit at a time.Serial ports are used for serial data communication and as interfaceswith some peripheral devices, such as mice and printers.

Service data Data which is saved in data disk. Service data is the data source forcomputing check data in parity disk.

Service networkport

The network port that is used to store services.

SFP opticaltransceiver

A component that can make data conversion between optical signalsand electrical signals and that can receive and transfer data.

Simple networkmanagementprotocol

A network management protocol of TCP/IP. It enables remote users toview and modify the management information of a network element.This protocol ensures the transmission of management informationbetween any two points. The polling mechanism is adopted to providebasic function sets. According to SNMP, agents, which can be hardwareas well as software, can monitor the activities of various devices on thenetwork and report these activities to the network console workstation.Control information about each device is maintained by a managementinformation block.

Single pointfailure

A type of failure. Data transmission over a network is stopped andcannot be recovered automatically if a single point failure occurs. Thepoint can be an interface, a board, a device, or a link.

Small computersystem interface

A set of standards for physically connecting and transferring databetween computers and peripheral devices. SCSI is most commonlyused for hard disks and tape drives, but it can connect a wide range ofother devices, including scanners, and optical drive.

SmartTenancy A feature of Huawei storage system. With SmartTenancy, multiplevirtual storage systems can be created in one physical storage system,which allows tenants to share the same storage system hardwareresource without affecting data security and privacy of each other. Thisfeature achieves more flexible, easy-to-manage and low-cost sharedstorage in a multi-protocol unified storage architecture.

OceanStor 5300 V3&5500 V3&5600 V3&5800 V3&6800V3 Storage SystemEvent Reference B Glossary

Issue 04 (2015-06-10) Huawei Proprietary and ConfidentialCopyright © Huawei Technologies Co., Ltd.

237

Snapshot A data backup technology through which a fully usable copy of a dataobject can be quickly generated. The duplicate contains the image ofthe data object at a point in time.

Snapshot copy A copy of the snapshot LUN, which is also a snapshot LUN.

Soft quota The value to alarm space usage in quota configuration. After used spacearrives this value, an alarm triggered; if space used from above this valuebecomes lower than, the previous alarm eliminated.

Storage system An integrated system. It consists of the following parts: controller,storage array, host bus adapter, physical connection between storageunits, and all control software.

Storage unit An abstract definition of backup storage media for storing backup data.The storage unit is connected with actual storage media, used to backup data.

Streaming media A transmission mode in which data is consumed (read, listened to, orwatched) while it is being sent.

Stripe The set of strips at corresponding locations of each member extent of adisk array which uses striped data mapping. The strips in a stripe areassociated with each other in a way (e.g., relative extent blockaddresses) that allows membership in the stripe to be quickly anduniquely determined by a computational algorithm. Parity RAID usesstripes to map virtual disk block addresses to member extent blockaddresses.

Subnet A type of smaller networks that form a larger network according to arule, for example, according to different districts. This facilitates themanagement of the large network.

Subnet mask The technique used by the IP protocol to determine which networksegment packets are destined for. The subnet mask is a binary patternthat is stored in the device and is matched with the IP address.

Synchronousremotereplication

A kind of remote replication. When the data on the primary site isupdated, the data must be synchronously updated on the mirroring sitebefore the update is complete. In this way, the data that is stored on boththe primary and mirroring sites can be synchronized.

T

Target A system component that can receive SCSI I/O operation commands.

Target LUN The target for LUN copy.

Tenant A property of SmartTenancy, which represents a virtual storage systemin a physical one. The private and independent logical resource of atenant mainly includes disk domain space, LUN, file system and ports.Tenants get complete storage services, but also remain resource andnetwork isolation with other tenants, which avoids interference.

OceanStor 5300 V3&5500 V3&5600 V3&5800 V3&6800V3 Storage SystemEvent Reference B Glossary

Issue 04 (2015-06-10) Huawei Proprietary and ConfidentialCopyright © Huawei Technologies Co., Ltd.

238

Thin provisioning A mechanism that offers on-demand allocation of storage space.

Thin LUN The thin LUN is a logic disk that can be accessed by hosts. The thinLUN dynamically allocates storage resources from the thin poolaccording to the actual capacity requirements of users.

Timing Snapshot To create snapshots periodically to continuously protect data.

Topology The logical layout where computer systems and network componentsare interconnected with one another. The topological structure gives theinterconnection relationship among the components from the viewpointof communication, but the topological structure does not specify theexact locations of components and the interconnection mode.

Trap A type of SNMP message that indicates the occurrence of an event. Thistype of message is transmitted to the received through UDP. Thetransmission process is not completely reliable.

U

User datagramprotocol

A TCP/IP standard protocol that allows an application program on onedevice to send a datagram to an application program on another. UserDatagram Protocol (UDP) uses IP to deliver datagram. UDP providesapplication programs with the unreliable connectionless packet deliveryservice. There is a possibility that UDP messages will be lost,duplicated, delayed, or delivered out of order. The destination devicedoes not confirm whether a data packet is received.

User interface The space in which users interact with a machine.

V

Variable prefetch A cache prefetch strategy. The size of the data to be prefetched is themultiple for prefetching multiplied by the length of a read command.This strategy applies to the applications that require reading data ofvariable size in a certain order or to the situations where multiplesubscribers read data concurrently but no fixed prefetch size can be set,because the amount of pre-read data cannot be judged. An example isthe streaming media demanded by multiple subscribers who usedifferent bit rates.

vStore A property of SmartTenancy. In Huawei SmartTenancy, a tenant iscalled a vStore, which represents a virtual storage system.

W

Workingcontroller

The controller that reads data from and writes data onto LUNs or filesystems in a storage array.

OceanStor 5300 V3&5500 V3&5600 V3&5800 V3&6800V3 Storage SystemEvent Reference B Glossary

Issue 04 (2015-06-10) Huawei Proprietary and ConfidentialCopyright © Huawei Technologies Co., Ltd.

239

Write back A caching technology in which the completion of a write request issignaled as soon as the data is in cache, and actual writing to non-volatilemedia occurs at a later time. Write back includes an inherent risk thatan application will take some action predicated on the write completionsignal, and a system failure before the data is written to non-volatilemedia will cause media contents to be inconsistent with that subsequentaction. For this reason, good write back implementations includemechanisms to preserve cache contents across system failures(including power failures) and to flush the cache at system restart time.

Write through A caching technology in which the completion of a write request is notsignaled until data is safely stored on non-volatile media. Writeperformance with the write through technology is approximately that ofa non-cached system, but if the data written is also held in cache,subsequent read performance may be dramatically improved.

Z

Zone In the fiber channel, a collection of the N_Port or the NL_Port whichcan communicate with each other in the optical network. Only theN_Port or the NL_Port in the same partition can communicate with eachother through the optical network.

OceanStor 5300 V3&5500 V3&5600 V3&5800 V3&6800V3 Storage SystemEvent Reference B Glossary

Issue 04 (2015-06-10) Huawei Proprietary and ConfidentialCopyright © Huawei Technologies Co., Ltd.

240

C Acronyms and Abbreviations

B

BBU Backup Battery Unit

F

FC Fiber Channel

H

HBA Host Bus Adapter

I

iSCSI Internet Small Computer Systems Interface

L

LUN Logical Unit Number

M

MAC Medium Access Control

OceanStor 5300 V3&5500 V3&5600 V3&5800 V3&6800V3 Storage SystemEvent Reference C Acronyms and Abbreviations