AEROSPACE & DEFENSE FEATURES 3 The first modern, digital, humidity sensor 3 Standard D38999 electrical connector 3 CANBUS output 3 Internal Built-In Test 3 Provides both humidity and temperature Humidity Sensor 8TJ315AAA1 DESCRIPTION AMETEK has now developed the most accurate and smartest humidity sensor available for aircraft Environmental Control Systems (ECS). Qualification is completed for a transport jet application. The humidity sensor contains the sensing element and the electronics to convert the water concentration in air to a standard CANBUS output. The humidity sensor uses a capacitance technique with specialized signal processing to measure water content. It is intended for an air ducting installation where humidified air is carried to seating areas. Time response is a function of airflow and typically is less than six seconds. The CANBUS output has labels of duct humidity and temperature and Built-In-Test status. Internal Built-In-Test (IBIT) capability indicates detected failures both with sensor and its internal processing circuits and microcontroller. The humidity sensor has passed tests in accordance with DO160, substantiating all the requirements for its location on transport aircraft.

Humidity Sensor 8TJ315AAA1 - ameteksfms.com

  • Upload
    others

  • View
    11

  • Download
    0

Embed Size (px)

Citation preview

AEROSPACE & DEFENSE

FEATURES

3 The first modern, digital,

humidity sensor

3 Standard D38999 electrical

connector

3 CANBUS output

3 Internal Built-In Test

3 Provides both humidity and

temperature

Humidity Sensor 8TJ315AAA1DESCRIPTIONAMETEK has now developed the most accurate and smartest humidity

sensor available for aircraft Environmental Control Systems (ECS).

Qualification is completed for a transport jet application. The humidity

sensor contains the sensing element and the electronics to convert the

water concentration in air to a standard CANBUS output.

The humidity sensor uses a capacitance technique with specialized signal

processing to measure water content. It is intended for an air ducting

installation where humidified air is carried to seating areas. Time response

is a function of airflow and typically is less than six seconds. The

CANBUS output has labels of duct humidity and temperature

and Built-In-Test status.

Internal Built-In-Test (IBIT) capability indicates detected

failures both with sensor and its internal processing

circuits and microcontroller.

The humidity sensor has passed tests in

accordance with DO160, substantiating

all the requirements for its location on

transport aircraft.

PRINTED IN THE U.S.A. © 2013, BY AMETEK, INC. ALL RIGHTS RESERVED. 1M913PDF (020198)

HEADQUARTERS50 Fordham Road • Wilmington, MA 01887 U.S.A. E-mail: [email protected]

AEROSPACE & DEFENSE www.ametekaerodefense.com

SALES: North America Tel: +1 978-988-4771 • Fax: +1 215-293-8995

EuropeTel: +49 8145 951767 • Fax: +49 8145 951768

Asia PacificTel: +65 6484 2388 (ext 118) • Fax: +65 6481 6588

A

B

CD

E F

ELECTRICAL/FUNCTIONAL INTERFACECONNECTOR PART NUMBER: D38999/25YB98CN

ABCDEF

PIN28VDC POWER---

DC GND---CAN HIGH---CAN LOW---

N/C---CASE GND---

3.17 ±.04(80.52 ±1)

3.00(76.20)

IMMERSIONDEPTH

.50(12.70)

MARKING LOCATIONAROUND CIRCUMFERENCE

NUT CAP

Ø.69(17.501)

MAXIMUM

.42(10.70)

M20 x 1.5 THREAD (fine)

5.51 +.04/-.09(139.93 +1/-2.30)

1 .00(25.4)

ACROSSFLATS

3X

1.18(30.0)

MAXIMUM

TEMPERATURE/ HUMIDITYSENSORWITH CAN BUSINTERFACE

IN(mm)

Humidity Sensor 8TJ315AAA1SPECIFICATIONS

DIMENSIONS

PERFORMANCE CHARACTERISTICS

Range: 10 to 90% humidity

Accuracy: ± 4% from 0°C to 50°C humidity 1.5°C from 0°C to 40°C temperature

Time Response: <40 seconds @ low flows, <10 seconds @ 45 feet/second

Input: 18 to 32 VDC

Current: 32 milliamp, nominal

Output: CANBUS label outputs for humidity, temperature, and BIT

Operating Temperature: -55°C to +85°C (-40°F to 158°F)

PERFORMANCE CHARACTERISTICS

Weight: < 0.44 lbs.