77
Shop Manual Model Numbers HHE-200-07E - 12 VDC HHE-500-07M - 12 VDC ®

Hydro-Hot Shop Manual Combined - myrvworks.com · 12 Volt-DC Battery Connections will seriously damage the Electronic Controller. Field Wiring Component Wiring Connections JP 3 JP

  • Upload
    others

  • View
    4

  • Download
    0

Embed Size (px)

Citation preview

Page 1: Hydro-Hot Shop Manual Combined - myrvworks.com · 12 Volt-DC Battery Connections will seriously damage the Electronic Controller. Field Wiring Component Wiring Connections JP 3 JP

Shop ManualModel NumbersHHE-200-07E - 12 VDCHHE-500-07M - 12 VDC

®

Page 2: Hydro-Hot Shop Manual Combined - myrvworks.com · 12 Volt-DC Battery Connections will seriously damage the Electronic Controller. Field Wiring Component Wiring Connections JP 3 JP

Hydro-Hot Hydronic Heating System Shop Manual 07/03R

Section 1 General Heater Information

1.1 Component Overview .............................................. 1

1.2 Identification Plate ................................................... 2

Section 2 Wiring Information

2.0 Wiring Information ................................................... 3

Section 3 Switch Panel

3.1 Diesel Switch ........................................................... 4

3.2 Electric Switch ......................................................... 4

3.3 Engine Preheat Switch............................................. 4

Section 4 Electronic Controller

4.1 Electric Heating Element Status Indicator Light ....... 5

4.2 Heating Zones Status Indicator Light ....................... 5

4.3 Low Voltage Reset Button ........................................ 6

4.4 Emergency Cutoff Indicator Light ............................. 6

4.5 Heating Status Indicator Light .................................. 6

4.6 Engine Preheat Pump Indicator Light ...................... 6

4.7 Circulation Pump #1 Indicator Light ......................... 6

4.8 Circulation Pump #2 Indicator Light ......................... 7

4.9 Stir Pump Indicator Light .......................................... 7

4.10 Low Battery Voltage Fault Indicator Light ................. 7

4.11 Low Temp Cutoff Status Indicator Light .................... 7

4.12 Diesel-Burner Status Indicator Light ......................... 7

4.13 Overload Fault Indicator Light .................................. 7

Section 5 Diesel-Burner

5.1 Component Overview. ............................................. 8

5.2 Operational Flow-Chart ............................................ 9

5.3 Operational Sequence ............................................ 10

5.4 Identification Plate .................................................. 13

TABLE OF CONTENTS

Contents

Page 3: Hydro-Hot Shop Manual Combined - myrvworks.com · 12 Volt-DC Battery Connections will seriously damage the Electronic Controller. Field Wiring Component Wiring Connections JP 3 JP

Hydro-Hot Hydronic Heating System Shop Manual 07/03R

Contents

TABLE OF CONTENTS

Section 6 Diesel-Burner Wiring

6.1 Control Unit Wiring ................................................. 14

Section 7 Troubleshooting

7.1 Troubleshooting ...................................................... 15

Section 8 Diesel-Burner Service, Maintenance, and RepairInformation

8.1 General Recommended Maintenance .................... 41

8.2 Detaching and Reattaching the Diesel-Burner ........Head ....................................................................... 42

8.3 Motor ...................................................................... 43

8.4 Flame Sensor ......................................................... 47

8.5 Ignition Electrodes .................................................. 48

8.6 Fuel Nozzle ............................................................. 50

8.7 Fuel Solenoid .......................................................... 52

8.8 Fuel Pump .............................................................. 54

8.9 Bearings ................................................................. 60

8.10 Ignition Coil ............................................................. 64

8.11 Control Unit ............................................................. 65

Section 9 Warranty Information

9.0 Warranty Information .............................................. 70

Section 10 Spare Parts List

10.0 Spare Parts List ...................................................... 71

Section 11 Special Tools

11.0 Special Tools ........................................................... 72

Page 4: Hydro-Hot Shop Manual Combined - myrvworks.com · 12 Volt-DC Battery Connections will seriously damage the Electronic Controller. Field Wiring Component Wiring Connections JP 3 JP

Hydro-Hot Hydronic Heating System Shop Manual 07/03R

1.1 Component OverviewComponentOverview

Section 1: General Heater Information

Figure 1

Page 1

Page 5: Hydro-Hot Shop Manual Combined - myrvworks.com · 12 Volt-DC Battery Connections will seriously damage the Electronic Controller. Field Wiring Component Wiring Connections JP 3 JP

Hydro-Hot Hydronic Heating System Shop Manual 07/03RPage 2

Section 1: General Heater Information

1.2 Identification PlateI.D. Plate

Figure 2

Model NumberBox

Serial NumberBox

ManufacturedDate Box

Model Number

Serial Number

Manufactured Date

Diesel-Burner / DC Power

Fuel Type / Firing Rate

Electric HeatingElement / AC Power

TestingEngineers

International

Complies with the requirementsof UL 307A

Made in U.S.A.

For Installation Only in Compartment CompletelyClosed Off from Living Quarters and Accessible

Only from the Outdoors

Exhaust system MUST NOT terminate beneaththe vehicle or under an openable window or vent.

Combustion Air MUST BE suppliedfrom outside the vehicle.

CAUTION: This appliance operates on both AC and DC Electrical Power.

The AC Powered Electrical Heating Element can bewired using flexible nonmetallic cable (ROMEX).

USE COPPER CONDUCTORS ONLY

CAUTION: The Mixing / Anti-Scald Valve must be installed with this product.

Use 25 Amp fuse for over current protectionfor DC Power supply.

Use 20 Amp Circuit Breaker for over currentprotection for AC Power supply.

Mount Heater near a Bay / Storage Door soAcess Cover can be easily removed.

Minimum Heater clearancesFront - Open Acess

Back - 8 inchesTop - 9 inches

Sides - 0 inches

Install in strict compliance with local codes, NFPA501c and manufacturer’s instructions.

HHE-500-07M

HM02-224

06-02

12 VDC / 170 Watts

120 VAC, 60 Hz / 1.65 kW

DIESEL / 50,000 BTU

Reference Figure 1 for I.D. Plate locations.

Page 6: Hydro-Hot Shop Manual Combined - myrvworks.com · 12 Volt-DC Battery Connections will seriously damage the Electronic Controller. Field Wiring Component Wiring Connections JP 3 JP

Hydro-Hot Hydronic Heating System Shop Manual 07/03R

rellortnoC cinortcel

Erellortno

C cinortcelE

rellortnoC cinortcel

EEle

ctro

nic

Con

trol

ler

- P

MU

PH

P+

PM

UP

HP

- W

S O

CWL

+ W

S O

CWL

- W

S T

ATS

T+

WS

TAT

ST

- W

S L

ER

CA

+ W

S L

ER

CA

- W

S O

CTL

+ W

S O

CTL

- 1P

MU

PZ

+ 1P

MU

PZ

- 2P

MU

PZ

+ 2P

MU

PZ

- P

MU

PT

S+

PM

UP

TS

1B

HC

TIW

S F

FO/

NO

7C

ETI

HW .

MR

EH

T

1C

EG

NA

RO .

MR

EH

T

2B -

DN

UO

RG

4B

+ Y

RE

TT

AB

3B

+ T

HGI

L R

OT

ACI

DNI

6B -

TH

GIL

RO

TA

CID

NI

renr

uB-lesei

Dti

nU l

ortn

oC

gniri

W

erutarepmeT

woLtatso

mrehT

CAV /

CD

Vtatso

mrehT lortnoC

1# pmu

P noitalucriC

pmu

P taeherP enign

E

yaleR tne

melE

CAV

hctiw

S taolF

pmu

P ritS

der-61der-51

kcalb-2n

worb-3neerg-4teloiv-5

etihw-6

der-7n

worb-8wolley-9wolley-01egnaro-11egnaro-21

kcalb-31kcalb-41

der-1

GEMS

RE

LT

TE

ZD

21-

A1-

08

22

ZA

2# pmu

P noitalucriC

stnenopmo

C toH-ordy

H

5-C

8-C

lioc noitingI

dioneloS leuF

rotoM renru

B

2-C

4-C

6-C

renruB-leseiD

tinU lortno

C

BA

C

GUL

P-B

wolley-7etih

w-6egnaro-5

nworb-4

der-3eulb-2

neerg-1

timiL-hgi

H C

DV

tatsomrehT

rosneS e

malF

wolley

neerg

nworb

kcalb

eulbG

ULP-

C

stnenopmo

C renruB-lesei

D

EL

CIH

EV

SM

ET

SY

S.

CNI

TO

H-O

RD

YH

RELL

OR

TN

OC

1 PJ

2 PJ

knaT reta

W hser

Fe

no

Z g

nitaeH

gnitae

H m

oor

deB

en

oZ

gnitae

H m

oor

htaB

en

oZ

/ m

oo

R g

niviL

nehcti

Ke

no

Z g

nitaeH

lan

oitp

O / yrossecc

Ae

no

Z g

nitaeH

+ L

ES

EID

- L

ES

EID

CI

DNI 3

B

CID

NI 6B

+ CI

RT

CE

LE

- CI

RT

CE

LE

+ T

AE

HE

RP

- T

AE

HE

RP

CD-tl

oV 21

yrettaB

sn

oitcen

no

C

lena

P hcti

wS

sn

oitcen

no

C

V21+

DN

G

+ N

AF 4 #-

NAF 4 #

+ M

RE

HT

4 #

- M

RE

HT

4 #

+ N

AF 3 #-

NAF 3 #

+ M

RE

HT

3 #

- M

RE

HT

3 #

+ N

AF 5 #-

NAF 5 #

+ M

RE

HT

5 #

- M

RE

HT

5 #

+ N

AF 2 #-

NAF 2 #

+ M

RE

HT

2 #

- M

RE

HT

2 #

+ N

AF 1 #-

NAF 1 #

+ M

RE

HT

1 #

- M

RE

HT

1 #

+ -der

kcalb

+-T

TAT

S

+-T

TAT

S

+ -der

kcalb

+-T

TAT

S

+ -der

kcalb

+-T

TAT

S

-tel

oivtel

oiv -eti

hw

etih

w -e

ulb

eul

b

-e

gnar

oe

gnar

o

+ -der

kcalb

+ eul

b

+ w

olley

- eg

naro

- eul

b

+ teloiv

- n

wor

b

+ neer

g

- etih

w

"L

ES

EID"

"CI

RT

CE

LE"

ENI

GN

E""

TA

EH

ER

P

+-

-+

)dnuorG( -

CDV 21

/ lanimreT

wercSeri

w kcalB

)evitisoP( + C

DV 21/ lani

mreT wercS

eriw de

R

,lena

P hcti

wS

weiV e

diskcaB

yeK

sregnahcxE tae

H III yzoC setacidnI -

knaT retaW hser

F / moo

R roiretnI setacidnI -statso

mrehT

-TT

ATS

- )" "( snoitcenno

C "evitisneS ytiralo

P" setacidnI

:ETO

N desu si rotcennoc gulp ya

w-owt ehT

YLN

Oredlo gnicalper neh

w .srellortno

C cinortcelE to

H-ordyH

+ -+ -

+ -

:N

OIT

UA

C eht ot ytiralop desreve

R lli

w snoitcennoC yretta

B C

D-tloV 21

cinortcelE eht ega

mad ylsuoires.rellortno

C

gniri

W dlei

Fs

noitce

nn

oC

gniri

W tne

no

pm

oC

sn

oitcen

no

C

3 PJ

4 PJ

:eto

N ,"snoitcenno

C gniriW dlei

F" rof ,nwohs sroloc eri

w llA

M

EO lautca

morf yrav yam "snoitcenno

C lenaP hcti

wS" dna

.sroloc gniriw retrevno

C /

margaiD gniri

WWi r

ing

Di a

gram

8924-586-008-1 llac troppuS lacinhceT roF

R

2455RM8589-6 L220

ttaW 0561/

CAV 021

tnemel

E gnitaeH cirtcel

E

timiL-hgi

H C

AVtatso

mrehT

nom

moC

ylppuS re

woP

CAV 021

kcalB

kcalB

kcalB

etihW

2455RM8589-6 L220

3 erugiF

Page 3

noitamrofnI gniri

W :2 noitceS

Page 7: Hydro-Hot Shop Manual Combined - myrvworks.com · 12 Volt-DC Battery Connections will seriously damage the Electronic Controller. Field Wiring Component Wiring Connections JP 3 JP

Hydro-Hot Hydronic Heating System Shop Manual 07/03R

By Vehicle Systems

Diesel Electric EnginePreheat

Diesel-Burner’sIndicator

Light

TM

�� ������������� ���R

Page 4

Section 3: General Heater Information

3.0 Switch PanelSwitch Panel

Figure 43.1 Diesel Switch

Function: The Diesel switch activates the indicator light on the switch andthe Hydro-Hot's Diesel-Burner, reference Figure 4. This procedure allowsthe Diesel-Burner to operate and supply heat to the Hydro-Hot's BoilerTank. The Diesel-Burner will heat the Hydro-Hot System to maximumoperating temperature (190�F {+/- 5 deg.}) in approximately 10-20 min-utes. Please note that the Diesel-Burner is the Hydro-Hot's primary heatsource for heating both the interior and/or the domestic hot water (suchas when cool ambient temperatures exist and/or when there is a highdemand for domestic hot water).

3.2 Electric Switch

Function: The Electric switch activates the indicator light on the switchand the Hydro-Hot's 120 VAC Electric Heating Element, reference Figure4. This procedure allows the 120 VAC Electric Heating Element to supplyheat to the Hydro-Hot's Boiler Tank. The 120 VAC Electric HeatingElement will heat the Hydro-Hot System to maixmum operating tempera-ture (190�F {+/- 5 deg.}) in approximately 1-2 hours. Please note the 120VAC Electric Heating Element is the Hydro-Hot's secondary heat sourcefor heating both the interior and/or the domestic hot water during lowheating demand situations (such as when moderate ambient tempera-tures exist and/or when there is a low demand for domestic hot water).This feature is only operational whenever the motorhome is connected toVAC power or when the generator is operating.

3.3 Engine Preheat Switch

Function: The Engine Preheat switch activates the indicator light on theswitch and the Hydro-Hot's Engine Preheat Circulation Pump, referenceFigure 4. This procedure allows the Engine Preheat Circulation Pump tocirculate the engine's coolant through a separate double wall copper loopin the Hydro-Hot's Boiler Tank, resulting in a warm engine for easy start-ups on cool mornings. Please note that this feature will be effective only ifthe Engine Preheat switch is ON in conjunction with either the Diesel and/or Electric switch. This feature is available on HHE-200 Model Hydro-Hot's, ONLY.

Page 8: Hydro-Hot Shop Manual Combined - myrvworks.com · 12 Volt-DC Battery Connections will seriously damage the Electronic Controller. Field Wiring Component Wiring Connections JP 3 JP

Hydro-Hot Hydronic Heating System Shop Manual 07/03R Page 5

4.1 Electric Heating Element Status Indicator Light

This indicator light will illuminate GREEN whenever the Hydro-Hot's 120VAC Electric Heating Element is operating and providing heat to the Hydro-Hot's Boiler Tank, reference Figure 5. Please note that this light will only beactive if the Electric switch is in the ON position, reference Figure 4. If thisindicator light illuminates RED, it indicates an electrical overload condition(i.e. short) has occurred in the Electric Heating Element's VDC poweredcircuitry.

4.2 Heating Zones Status Indicator Lights

These five indicator lights (separately) will illuminate GREEN whenever aZone Thermostat, for each particular zone, is calling for heat, referenceFigure 5. The GREEN indicator lights also indicate that VDC power is beingsupplied to the particular interior heating zone's Heat Exchangers (i.e. fanmotors). If any of the five indicator lights illuminate RED, it indicates that anelectrical overload condition (i.e. short) has occurred in a particular heatingzone's circuitry.

NOTE: A short in either a heating zone's Thermostat or a heating zone'sHeat Exchanger circuit, will cause the indicator light to illuminate RED.

Section 4: General Heater Information

ElectronicController

Figure 5

Heating ZonesStatus

#5

#4

#3

#2

#1

Electric HeatingElement Status

Low Voltage

Reset

EmergencyCutoff

Hydro-HotHeating Status

Engine PreheatPump

ElectronicController

Low BatteryVoltage Fault

Low TempCutoff Status

Overload Fault

CirculationPump #2

CirculationPump #1

Stir Pump

Diesel-BurnerStatus

TM

�� ������������� ���R

4.0 Electronic Controller

Page 9: Hydro-Hot Shop Manual Combined - myrvworks.com · 12 Volt-DC Battery Connections will seriously damage the Electronic Controller. Field Wiring Component Wiring Connections JP 3 JP

Hydro-Hot Hydronic Heating System Shop Manual 07/03RPage 6

Section 4: General Heater Information

4.3 Low Voltage Reset (Button)

The Hydro-Hot's Electronic Controller must be manually reset whenever theLow Battery Voltage fault indicator light has been activated, referenceFigure 5. To reset the Electronic Controller, simply depress the "LowVoltage Reset" button located on the Electronic Controller (use a thinstraight object to access the reset button through the small hole in thefaceplate).

4.4 Emergency Cutoff Indicator Light

This indicator light will illuminate RED when either the 120 VAC ElectricHeating Element and/or the Diesel-Burner have automatically shutdowndue to a low water and antifreeze solution level inside the Hydro-Hot'sBoiler Tank, reference Figure 5. This fault will automatically reset when thelow level condition is corrected.

4.5 Heating Status Indicator Light

This indicator light will illuminate GREEN whenever the Hydro-Hot's VDC /VAC Control Thermostat is calling for heat, allowing the water andantifreeze solution in the Hydro-Hot's Boiler Tank to be heated by either theDiesel-Burner and/or the 120 VAC Electric Heating Element, referenceFigure 5. When this indicator light is off, no heat is being supplied to theHydro-Hot's Boiler Tank. Please note that this light will only be active ifeither the Diesel and/or the Electric switch are turned ON, reference Figure4.

NOTE: The Hydro-Hot's VDC / VAC Control Thermostat will automat-ically activate the Diesel-Burner and/or the 120 VAC Electric HeatingElement, only if the Diesel and/or Electric switch is in the ON position.So to heat the motorhome / domestic hot water, simply choose thedesired heat source(s) and leave the switch(s) (i.e. Diesel and/orElectric) ON.

4.6 Engine Preheat Pump Indicator Light

This indicator light will illuminate GREEN whenever the Engine PreheatPump is operating, reference Figures 1 and 5. Please note that this lightwill only be active if the Engine Preheat switch is ON in conjunction witheither the Diesel and/or the Electric switch, reference Figure 4. If thisindicator light illuminates RED, it indicates an electrical overload condition(i.e. short) has occurred in this particular component's circuitry.

4.7 Circulation Pump #1 Indicator Light

This indicator light will illuminate GREEN whenever Circulation Pump #1 isoperating, reference Figures 1 and 5. Please note that this light will only beactive if the Hydro-Hot is at normal operating temperature (i.e. between160�����F and 190�����F) and if either Heating Zone #1 or #5 are calling for heat,reference Figure 3. If this light illuminates RED, it indicates an electricaloverload condition (i.e. short) has occurred in this particular component'scircuitry.

ElectronicController,continued

Page 10: Hydro-Hot Shop Manual Combined - myrvworks.com · 12 Volt-DC Battery Connections will seriously damage the Electronic Controller. Field Wiring Component Wiring Connections JP 3 JP

Hydro-Hot Hydronic Heating System Shop Manual 07/03R

4.8 Circulation Pump #2 Indicator Light

This indicator light will illuminate GREEN whenever Circulation Pump #2 isoperating, reference Figures 1 and 5. Please note that this light will only beactive if the Hydro-Hot is at normal operating temperature (i.e. between160�����F and 190�����F) and if either Heating Zones #2, #3, or #4 are calling forheat, reference Figure 3. If this light illuminates RED, it indicates anelectrical overload condition (i.e. short) has occurred in this particularcomponent's circuitry.

4.9 Stir Pump Indicator Light

This indicator light will illuminate GREEN whenever there is a continuousdemand for domestic hot water (i.e. during a shower), reference Figures 1and 5. Please note that this light will be active only when the Diesel switchis turned ON, reference Figure 4.

4.10 Low Battery Voltage Fault Indicator Light

This indicator light will illuminate RED whenever the VDC voltage level istoo low for the Hydro-Hot to operate properly, reference Figure 5. This faultmust be manually reset after the voltage level has been restored to the VDCbattery system, reference Section 4.3 for reset instructions.

4.11 Low Temp Cutoff Status Indicator Light

This indicator light will illuminate GREEN whenever the Hydro-Hot is able toprovide heat for both the Interior and Fresh Water Tank Heating Zones,reference Figure 5. Whenever this indicator light is OFF, it indicates thatdomestic hot water is being used on a continuous basis (i.e. during ashower).

NOTE: The Hydro-Hot will not provide both interior zone heating and acontinuous supply of domestic hot water simultaneously; Domestic HotWater will take priority over Interior Heating. This is referred to as the"Domestic Water Priority System".

4.12 Diesel-Burner Status Indicator Light

This indicator light will illuminate GREEN whenever the Hydro-Hot's Diesel-Burner is operating and supplying heat to the Hydro-Hot's Boiler Tank,reference Figures 1 and 5. Please note that this light will only be active ifthe Diesel switch is turned ON, reference Figure 4.

4.13 Overload Fault Indicator Light

This indicator light will illuminate RED (reference Figure 5) whenever one ofthe following conditions have occurred:

1. The Hydro-Hot is off due to an electrical overload (i.e. short) in themain VDC power supply circuitry.

2. The Hydro-Hot is off due to a combination of high electrical VDCpower loads and a high surface temperature of the ElectronicController.

The Hydro-Hot will automatically restart once the electrical overload (i.e.short) and/or high heat condition is corrected.

Page 7

Section 4: General Heater Information

ElectronicController,continued

Page 11: Hydro-Hot Shop Manual Combined - myrvworks.com · 12 Volt-DC Battery Connections will seriously damage the Electronic Controller. Field Wiring Component Wiring Connections JP 3 JP

Hydro-Hot Hydronic Heating System Shop Manual 07/03RPage 8

ComponentOverview

1. Control Unit 10. Heat Exchanger2. Motor 11. Combustion Chamber3. Ignition Coil 12. Exhaust Port4. Clutch 13. Flame Sensor5. Combustion Air Blower 14. Fuel Pump6. Fuel Solenoid 15. Fuel Ports (Supply / Return)7. Electrode Holder 16. Combustion Air Intake Port,8. Ignition Electrodes with Adjustable Shutter9. Fuel Nozzle

5.1 Component Overview

Section 5: Diesel-Burner

Figure 6

Page 12: Hydro-Hot Shop Manual Combined - myrvworks.com · 12 Volt-DC Battery Connections will seriously damage the Electronic Controller. Field Wiring Component Wiring Connections JP 3 JP

Hydro-Hot Hydronic Heating System Shop Manual 07/03R Page 9

Operation sequence once the Hydro-Hot’s Diesel switch is

turned ON.

NOTE:The Diesel switch’s IndicatorLight will illuminate (reference Figure 4), while the Hydro-Hot

Heating Status and Diesel-Burner Status lights illuminate on the Electronic Controller,

reference Figure 5.

The Motor (#2), which turns the Combustion Air Blower

(#5) and drives the Fuel Pump(#14), will begin to operate.

NOTE:If the Hydro-Hot’s coolant

temperature is approximately 190 (+/- 5 deg.) degrees

fahrenheit, or higher, the Motor(#2) will not operate. Only

when the coolant temperature has dropped below 160 (+/- 5 deg.) degrees fahrenheit, and

the VDC / VAC Control Thermostat (see Figure 3) is calling for heat, will the Motor

(#2) begin to operate.

After approximately 10 - 25 seconds, the Fuel Solenoid

(#6) opens and fuel is sprayed into the

Combustion Chamber (#11)through the Fuel Nozzle (#9).

SUMMARY:The Hydro-Hot’s Diesel-Burner

is operational anytime the operator activates the Dieselswitch (reference Figure 4) to the ON position. The Diesel-

Burner will then automatically maintain the coolant

temperature in the Hydro-Hot’s Boiler Tank without additional

involvement from the operator.

The combustion process will continue to operate in this

manner until one of the followingtake’s place:

A.) The VDC / VAC Control Thermostat (see Figure 3),

which senses coolant temperature, reaches the preset

temperature of approximately 190 (+/-5 deg.) degrees

fahrenheit.

NOTE:If process "A" occurs, the Low

Temp Cutoff Status, Hydro-HotHeating Status, and Diesel-Burner Status lights on the

Electronic Controller will go OFF, reference Figure 5.

B.) The Hydro-Hot’s Dieselswitch is turned OFF.

NOTE:If process "B" occurs, the Dieselswitch’s Indicator Light, on the Switch Panel (reference Figure

4), will go OFF along with the Hydro-Hot Heating Status,

Diesel-Burner Status, and StirPump lights on the ElectronicController, reference Figure 5.

Once the ignited air-fuel mixture (FLAME) is observed by the Flame Sensor (#13),

the Ignition Coil (#3) will automatically switch OFF. The

combustion process now continues to operate

unassisted.

Simultaneously the IgnitionCoil (#3) produces a high voltage spark across the Ignition Electrodes (#8),which ignites the incoming

air-fuel mixture.

The Motor (#2) will continue to run for approximately three (3) additional minutes. This process is refered to as the purge-cycle, which cools down the heater’s internal

components and purges the Combustion Chamber (#11)

of any residual exhaust gases.

NOTE: When the Hydro-Hot’s Diesel-Burner is switched OFF, by the VDC / VAC Control Thermostat

(see Figure 3), the following process will take place:

1.) The Motor (#2) will shut-off once the three (3) minute purge-

cycle has expired.-THEN-

2.) The Hydro-Hot’s Diesel-Burner will automatically turn

back ON once the coolant temperature reaches the preset temperature of approximately

160 (+/- 5 deg.) degrees fahrenheit.

Once the heater switches OFF,thermostatically or manually,

the Fuel Solenoid (#6) closes, which interrupts the supply of diesel fuel to the Fuel Nozzle

(#9).

5.2 Operational Flow-Chart

Section 5: Diesel-Burner

OperationalFlow-Chart ~ Reference Figure 6 for all numbers indicated inside parenthesis. (e.g. #8).

Page 13: Hydro-Hot Shop Manual Combined - myrvworks.com · 12 Volt-DC Battery Connections will seriously damage the Electronic Controller. Field Wiring Component Wiring Connections JP 3 JP

Hydro-Hot Hydronic Heating System Shop Manual 07/03RPage 10

The Fuel Pump builds up pressure against the Fuel Solenoid. After

approximately 10 - 25 seconds, the FuelSolenoid opens and fuel is released into

the Fuel Nozzle and then sprayed into the Combustion Chamber.

Fuel Pump

Fuel SolenoidFuel Nozzle

CombustionChamber

The particular component begins to operate.

The component is currently operating.

Diesel-Burner Operation

The following sequence illustrates how the Hydro-Hot’s Diesel-Burner operates once it is activated. Also, if you are experiencing malfunctions with your Diesel-Burner, use this sequence of operating events as a diagnostic tool to determine at what point, in the Diesel-Burner’s operation, does the malfunction occur. Use the "KEY" provided below to understand each symbol shown.

1

2

Diesel Fuel(Supply and Return)

Motor

CombustionAir Blower

CombustionAir

NOTE: The Motor and CombustionAir Blower will begin to operate only if the VDC / VAC Control

Thermostat is closed and calling for heat, reference Figure 3.

Combustion Air

Diesel Fuel Spray

Exhaust Gases

When the Diesel switch is turned ON, the Motorand Combustion Air Blower begin to operate. This

process is referred to as the prime-cycle.

KEY

Section 5: Diesel-Burner

5.3 Operational Sequence

OperationalSequence

Page 14: Hydro-Hot Shop Manual Combined - myrvworks.com · 12 Volt-DC Battery Connections will seriously damage the Electronic Controller. Field Wiring Component Wiring Connections JP 3 JP

Hydro-Hot Hydronic Heating System Shop Manual 07/03R Page 11

The Ignition Coil produces a high voltage spark, which is transferred across the Ignition Electrodes. The incoming air-fuel mixture is then

ignited, creating combustion.

IgnitionElectrodes

Ignition Coil

Combustion

The combustion’s flame is detected by the Flame Sensor and the Ignition Coil is then automatically switched off (no more spark

across the Ignition Electrodes).

FlameSensor

Diesel-Burner Operation, continued

3

4

Hot ExhaustGases

The particular component begins to operate.

The component is currently operating.

Combustion Air

Diesel Fuel Spray

Exhaust Gases

KEY

Section 5: Diesel-Burner

5.3 Operational Sequence

OperationalSequence,continued

Page 15: Hydro-Hot Shop Manual Combined - myrvworks.com · 12 Volt-DC Battery Connections will seriously damage the Electronic Controller. Field Wiring Component Wiring Connections JP 3 JP

Hydro-Hot Hydronic Heating System Shop Manual 07/03RPage 12

Diesel-Burner Operation, continued

The Diesel-Burner will continue to operate continuously in this manner (produce heat) until it is switched off manually, or by the VDC / VAC Control Thermostat once the coolant temperature in the Hydro-Hot’s

Boiler Tank reaches 190 (+/- 5 deg.) farenheit.5

Cool ExhaustGases

6

NOTE: If the Diesel-Burner is switched off by the VDC / VAC Control Thermostat, it will automatically reactivate the Diesel-

Burner whenever the Hydro-Hot Boiler Tank’s coolant temperature has dropped below 160 (+/- 5 deg.) degrees fahrenheit.

Once the Diesel-Burner has switched OFF, the Motor and Combustion Air

Blower will continue to operate for approx. 2-3 minutes. This process is referred to

as the purge-cycle.

The particular component begins to operate.

The component is currently operating.

Combustion Air

Diesel Fuel SprayKEY

Section 5: Diesel-Burner

5.3 Operational Sequence

OperationalSequencecontinued

Page 16: Hydro-Hot Shop Manual Combined - myrvworks.com · 12 Volt-DC Battery Connections will seriously damage the Electronic Controller. Field Wiring Component Wiring Connections JP 3 JP

Hydro-Hot Hydronic Heating System Shop Manual 07/03R Page 13

5.4 Identification Plate

Section 5: Diesel-Burner

I.D. Plate

Figure 7

Fabrikschild-Duplikatgultig nur zusammen mit Original

Thermosysteme GmbHMADE IN GERMANY

HEIZGERAT TypSpannung / El. LeistungWarmestromBrennstoffzul. BetriebsuberdruckPrufzeichenFabriknummerInbetriebnahmejahr 2001 2002 2003

DBW 2010.7512 V / 60W

13,2 kWDiesel2 bar

1B230410

Model TypeVoltage / Wattage

Fuel Type

Serial Number (230410)Year Manufactured

To be shipped withOriginal Heater

Diesel-BurnerI.D. Plate

Diesel-BurnerHead

Page 17: Hydro-Hot Shop Manual Combined - myrvworks.com · 12 Volt-DC Battery Connections will seriously damage the Electronic Controller. Field Wiring Component Wiring Connections JP 3 JP

Hydro-Hot Hydronic Heating System Shop Manual 07/03RPage 14

C-2 ( + ) Motor Circuit (Black Wire)to Diesel-Burner.

B-2 ( - ) Battery Circuit (Brown Wire)to JP-4 (Pin 4)

B-4 ( + ) Battery Circuit (Red Wire)to JP-4 (Pin 3)

C-8 ( + ) Ignition Coil Circuit (Yellow Wire)to Diesel-Burner.

C-6 ( + ) Flame Sensor Circuit (Green Wire)to Diesel-Burner.

C-PlugB-Plug B-1 B-2

B-3 (+) Indicator Light Circuit (Blue Wire) to JP-4, (Pin 2).

B-1 ( + ) On / Off Switch Circuit, with Low Voltage Protection (Yellow Wire) toJP-4 (Pin 7).

B-3B-4 B-6

C-1C-8C-7C-6C-4C-2

C-5

B-6 ( - ) Indicator Light Circuit (Green Wire) to JP-4 (Pin 1).

C-5 ( - ) Ground Circuit (Brown Wire), forDiesel-Burner components, to Diesel-Burner.

C-7 ( + ) VDC / VAC Control Thermostat Circuit (White Wire) to JP-4 (Pin 6).

C-1 ( + ) VDC / VAC Control Thermostat Circuit (Orange Wire) to JP-4 (Pin 5).

NOTE: Reference Figure 3 for all "JP" Plug and Pin locations on the Electronic Conroller.

C-4 ( - ) VDC High-Limit Thermostat Circuit (Blue Wire) to Hydro-Hot’s

Boiler Tank.

6.1 Control Unit Wiring

Section 6: Diesel Burner Wiring

ControlUnit Wiring

Figure 8

Page 18: Hydro-Hot Shop Manual Combined - myrvworks.com · 12 Volt-DC Battery Connections will seriously damage the Electronic Controller. Field Wiring Component Wiring Connections JP 3 JP

Hydro-Hot Hydronic Heating System Shop Manual 07/03R Page 15

Section 7: Troubleshooting

This Troubleshooting Section has been separated into different Hydro-Hot Troubleshooting Scenario's,that may be experienced by the heater. Each section listed below begins with the most probable causeand remedy, to the least probable cause and remedy. This concept has been put in place to expedite thetroubleshooting process and pinpoint the problem quickly. However, if you need additional assistance,please feel free to contact our Technical Department at 1-800-685-4298 or e-mail them by going towww.vehiclesys.com and clicking on the Technical Support button. Also, please review the following"KEY", prior to troubleshooting, as it may be helpful in understanding each nomenclature.

KEY:

TS#: (i.e. TS1, TS2, ....) = Troubleshooting Scenario 1, Troubleshooting Scenario 2, ....

Q#: (i.e. Q1, Q2,....) = Question 1, Question 2, ....

A: = Answer

After turning the Diesel switch ON: Section

TS1 - The Hydro-Hot's Diesel-Burner does not operate. ................................................................. 7.1

TS2 - The Hydro-Hot's Diesel-Burner operates (3-minute prime cycle only), ...................................but does not ignite. ................................................................................................................ 7.2

TS3 - The Hydro-Hot's Diesel-Burner ignites after several starting attempts. .................................. 7.3

TS4 - The Hydro-Hot's exhaust system sputters. ............................................................................ 7.4

TS5 - The Hydro-Hot's exhaust system produces white smoke after ignition. ................................. 7.5

TS6 - The Hydro-Hot's exhaust system produces black smoke after ignition. ................................. 7.6

Other troubleshooting issues:

TS7 - The Hydro-Hot is at operating temperature, but an Interior and/or Fresh ............................... Water Tank Heating Zone is not producing heat. .................................................................. 7.7

TS8 - The Hydro-Hot is at operating temperature, but the fans of an Interior ..................................and/or Fresh Water Heat Exchangers are not operating. ....................................................... 7.8

TS9 - The Hydro-Hot is at operating temperature, but the domestic hot water system is not producing hot water. ........................................................................................ 7.9

After turning the Electric switch ON:

TS10 - The Hydro-Hot's 120 VAC Electric Heating Element does not operate(i.e. lack of hot water and/or interior heat). ............................................................................. 7.10

After turning the Engine Preheat switch ON:TS11 - The Hydro-Hot's Engine Preheat System does not preheat the engine. ................................ 7.11

Troubleshooting

Page 19: Hydro-Hot Shop Manual Combined - myrvworks.com · 12 Volt-DC Battery Connections will seriously damage the Electronic Controller. Field Wiring Component Wiring Connections JP 3 JP

Hydro-Hot Hydronic Heating System Shop Manual 07/03RPage 16

After turning the Diesel switch ON:

TS1: The Hydro-Hot's Diesel-Burner does notoperate.

NOTE: In order to perform the following checks,it is necessary to locate the Hydro-Hot's Elec-tronic Controller and Switch Panel.

Q1: Is the Electronic Controller's EmergencyCutoff light Illuminated?A: If YES:

Perform each of the followingprocedures as necessary until theproblem is resolved.

If NO:Proceed to Q2.

WARNING: DO NOT remove theHydro-Hot's Radiator Cap when theheater is at maximum operatingtemperature, reference Figure 1.Hot coolant can be present andserious personal injury may result.

a. Check the coolant level in the Hydro-Hot'sExpansion Tank, and then the Boiler Tank ifnecessary.A: If coolant level is okay:

Continue troubleshooting.If coolant level is low:

Add coolant and attempt heaterrestart.

b. Check for continuity at the Float Switch,reference Figures 1 and 3.A: If continuity exists:

Continue troubleshooting.If continuity does not exist:

The Float Switch must be replaced.Please contact our Technical Depart-ment at 1-800-685-4298 for assis-tance.

c. Remove the Electronic Controller's Faceplateand use a jumper wire to make a connectionfrom Pin 15 to Pin 16 on the JP-3 Plug,reference Figure 3. Does the EmergencyCutoff light go off?

Section 7: Troubleshooting

Section 7.1 Section 7.1,continued

Switch Panel

By Vehicle Systems

Diesel Electric EnginePreheat

Diesel-Burner’sIndicator

Light

TM

�� ������������� ���R

Heating ZonesStatus

#5

#4

#3

#2

#1

Electric HeatingElement Status

Low Voltage

Reset

EmergencyCutoff

Hydro-HotHeating Status

Engine PreheatPump

ElectronicController

Low BatteryVoltage Fault

Low TempCutoff Status

Overload Fault

CirculationPump #2

CirculationPump #1

Stir Pump

Diesel-BurnerStatus

TM

�� ������������� ���R

Electronic ControllerFaceplate

Page 20: Hydro-Hot Shop Manual Combined - myrvworks.com · 12 Volt-DC Battery Connections will seriously damage the Electronic Controller. Field Wiring Component Wiring Connections JP 3 JP

Hydro-Hot Hydronic Heating System Shop Manual 07/03R Page 17

and/or loose connections, andensure that all of the Hydro-Hot'selectrical motors are operatingnormally when under load.

NOTE: If after testing and correcting the batterysystem, the Low Battery Voltage Fault indicatorlight continues to illuminate, and/or if the LowVoltage Reset (button) will not reset, the Elec-tronic Controller must be replaced. Pleasecontact our Technical Department at 1-800-685-4298 for assistance.

Q3: Is the Electronic Controller's Diesel-Burner Status light illuminated?A: If NO:

Perform each of the followingprocedures as necessary until theproblem is resolved.

If YES:Proceed to Q5.

a. Remove the Electronic Controller's Faceplate.Use a jumper wire to make a connection fromthe Diesel (+) to the Diesel (-) on the JP-2Plug, reference Figure 3. Does the Diesel-Burner Status light illuminate?A: If YES:

The Diesel switch must be replaced.Please contact our Technical Depart-ment at 1-800-685-4298 for assis-tance. Attempt heater restart.

If NO:Continue troubleshooting.

b. Turn the Diesel switch OFF (also, make surethe Electric switch is OFF ). Use a jumperwire to make a connection from Pin 13 to Pin14 on the JP-3 Plug, reference Figure 3. Withthe jumper wire in place, turn the Dieselswitch ON. Does the Diesel-Burner ignite andthe Diesel-Burner Status light illuminate?A: If YES:

The VDC / VAC Control Thermostatmust be replaced, reference Figure3. Please contact our Technical

A: If YES:Check the JP-3 Plug for loose wireconnections and/or harness damage.

If NO:The Electronic Controller must bereplaced. Please contact our Techni-cal Department at 1-800-685-4298 forassistance.

Q2: Is the Electronic Controller's Low BatteryVoltage Fault light illuminated?A: If YES:

Perform each of the followingprocedures as necessary until theproblem is resolved.

If NO:Proceed to Q3.

a. Remove the Electronic Controller's Faceplate.Check the DC battery voltage level at thesupply batteries and at the ElectronicController's Battery Connections, referenceFigure 3. Both voltage readings should bebetween 11.5 and 14.0 volts.A: If the voltage level is within specs:

Continue troubleshooting.If the voltage level is out of specs:

Recharge and/or replace batteries, ifnecessary.

b. Reset the Low Voltage Reset (button) on theElectronic Controller (this can be accom-plished by using a thin straight object toaccess the reset button through the smallhole in the Faceplate). Continue to read thevoltage level at the Electronic Controller'sBattery Connections and then turn the Dieselswitch ON. Under load, is the voltage levelwithin 0.5 volts of the supply battery's volt-age?A: If YES:

See the "NOTE" at the top right ofthis page.

If NO:Load-test the supply batteries,inspect battery wiring for damage

Section 7.1,continued

Section 7: Troubleshooting

Section 7.1,continued

Page 21: Hydro-Hot Shop Manual Combined - myrvworks.com · 12 Volt-DC Battery Connections will seriously damage the Electronic Controller. Field Wiring Component Wiring Connections JP 3 JP

Hydro-Hot Hydronic Heating System Shop Manual 07/03R

Department at 1-800-685-4298 forassistance.

If NO:The Electronic Controller must bereplaced. Please contact our Techni-cal Department at 1-800-685-4298 forassistance.

NOTE: If no problems were discovered up tothis point, the problem most likely lies withinthe Diesel-Burner Head. However, prior totroubleshooting the Diesel-Burner Head, besure to review the "Operational Flow-Chart"in Section 5.2, the "Operational Sequence"in Section 5.3, and the "Function" section foreach of the Diesel-Burner Components,reference Sections 8.3 thru 8.11. This informa-tion may help determine at what point theDiesel-Burner fails to operate.

Q4: Is the Diesel-Burner's Motor operating?Quick Check - Listen at the heater for theDiesel-Burner's Motor to operate, or check foroutput air at the heater's exhaust pipe.A: If the Motor does not seem to be operating:

Reference Section 8.3 and performthe Motor's "Component Test".

If the Motor is operating:Continue troubleshooting.

Q5: Is the Diesel-Burner's Control Unit func-tioning properly?In order to determine if the Control Unit isfunctioning properly, reference Section 8.11and perform the Control Unit's "ComponentTest".A: If the Control Unit is not functioning prop-

erly:The Control Unit must be replaced,reference Section 8.11 for replace-ment instructions.

If the Control Unit is functioning properly:See the "NOTE" on the top left-handside of the following page.

Section 7.1,continued

Section 7: Troubleshooting

IgnitionElectrodes Photo Disc

Flame Sensor

Fuel Pump

Fuel Solenoid

FuelNozzle

ControlUnit

Ignition Coil

Diesel-BurnerControl

Unit

Diesel-BurnerHead

Section 7.1,continued

Page 18

Page 22: Hydro-Hot Shop Manual Combined - myrvworks.com · 12 Volt-DC Battery Connections will seriously damage the Electronic Controller. Field Wiring Component Wiring Connections JP 3 JP

Hydro-Hot Hydronic Heating System Shop Manual 07/03R

a. Turn the Diesel switch ON and allow theHydro-Hot to reach operating temperature(i.e. until the Diesel-Burner cycles OFF).Locate both the VDC High-Limit Thermostatand the VAC / VDC Control Thermostat andcheck them for continuity, reference Figure 1.A: If there is no continuity at the VDC High-

Limit Thermostat, but there is continuity atthe VAC / VDC Control Thermostat:

The VAC / VDC Control Thermostatmust be replaced. Please contactour Technical Department at 1-800-685-4298 for assistance.

If there is continuity at the VDC High-LimitThermostat, but none at the VAC / VDCControl Thermostat:

The overheat condition may havebeen caused by another faultycomponent and no further trouble-shooting is necessary, see the"NOTE" below and please contactour Technical Department at 1-800-685-4298 for additional assistance.

NOTE: If the VDC High-Limit Thermostatcontinues to trip, and no overheating problemswere discovered (i.e. faulty VAC / VDC ControlThermostat or Control Unit), it may be that theVDC High-Limit Thermostat is not operatingproperly and it may need to be replaced.

Q2: Is the Diesel-Burner's Fuel Nozzle func-tioning properly?In order to determine if the Fuel Nozzle isfunctioning properly, reference Section 8.6and perform the Fuel Nozzle's "ComponentTest".A: If the Fuel Nozzle is not functioning

properly:The Fuel Nozzle must be replaced,reference Section 8.6 for replace-ment instructions.

If the Fuel Nozzle is functioning properly:Continue Troubleshooting.

After turning the Diesel switch ON:

TS2: The Hydro-Hot's Diesel-Burner operates(3-minute prime cycle only), but doesnot ignite.

NOTES:A. It is ideal to have the Hydro-Hot's Fuel Filter

replaced yearly, reference Section 8.1. Aplugged Fuel Filter will not allow the Diesel-Burner to operate properly. Also, beforeproceeding on to the following procedures,be sure to check that the vehicle's fueltank has a sufficient level of fuel.

B. In order to perform some of the followingprocedures it may be necessary to detachthe Diesel-Burner Head from the Hydro-Hot.Therefore, be sure to reference Section 8.2for detaching and reattaching instructions.

Q1: Has the Hydro-Hot's VDC High-Limit Ther-mostat tripped?Locate the VDC High-Limit Thermostat andcheck for continuity, reference Figure 1. Iscontinuity present?A: If YES:

Proceed to Q2.If NO:

Press the red reset button located onthe VDC High-Limit Thermostat andattempt heater restart.

NOTE: Although the Diesel-Burner is nowfunctioning, be sure to perform the followingsteps until the cause for overheating has beendiscovered and corrected. Failure to do socould result in another overheating condition.

Section 7: Troubleshooting

Section 7.2

Section 7.1,continued

Page 19

NOTE: If the Hydro-Hot still does not operateafter performing all of the listed checks, contactour Technical Department at 1-800-685-4298 foradditional assistance.

Section 7.2,continued

Page 23: Hydro-Hot Shop Manual Combined - myrvworks.com · 12 Volt-DC Battery Connections will seriously damage the Electronic Controller. Field Wiring Component Wiring Connections JP 3 JP

Hydro-Hot Hydronic Heating System Shop Manual 07/03R

Diesel-BurnerControl

Unit

Diesel-BurnerHead

Q3: Is the Diesel-Burner's Fuel Solenoidfunctioning properly?In order to determine if the Fuel Solenoid isfunctioning properly, reference Section 8.7and perform the Fuel Solenoid's "ComponentTest".A: If the Fuel Solenoid is not functioning

properly:The Fuel Solenoid must be replaced,reference Section 8.7 for replacementinstructions.

If the Fuel Solenoid is functioning properly:Continue Troubleshooting.

Q4: Is the Diesel-Burner's Control Unit func-tioning properly?In order to determine if the Control Unit isfunctioning properly, reference Section 8.11and perform the Control Unit's "ComponentTest".A: If the Control Unit is not functioning prop-

erly:The Control Unit must be replaced,reference Section 8.11 for replace-ment instructions.

If the Control Unit is functioning properly:Continue Troubleshooting.

Q5: Is the Diesel-Burner's Ignition Coil func-tioning properly?In order to determine if the Ignition Coil isfunctioning properly, reference Section 8.10and perform the Ignition Coil's "ComponentTest".A: If the Ignition Coil is not functioning

properly:The Ignition Coil must be replaced,reference Section 8.10 for replace-ment instructions.

If the Ignition Coil is functioning properly:Continue Troubleshooting.

Q6: Are the Diesel-Burner's Ignition Electrodesin good condition and properly adjusted?

Section 7: Troubleshooting

Section 7.2,continued

Section 7.2,continued

IgnitionElectrodes Photo Disc

Flame Sensor

Fuel Pump

Fuel Solenoid

FuelNozzle

ControlUnit

Ignition Coil

Page 20

Page 24: Hydro-Hot Shop Manual Combined - myrvworks.com · 12 Volt-DC Battery Connections will seriously damage the Electronic Controller. Field Wiring Component Wiring Connections JP 3 JP

Hydro-Hot Hydronic Heating System Shop Manual 07/03R

In order to determine if the Ignition Electrodesare in good condition and properly adjusted,reference Section 8.5.A: If the Ignition Electrodes are in poor

condition:The Ignition Electrodes must bereplaced, reference Section 8.5 forreplacement instructions.

If the Ignition Electrodes are not properlyadjusted:

Adjust the Ignition Electrodes,reference Section 8.5 for adjustmentinstructions.

If the Ignition Electrodes are both in goodcondition and properly adjusted:

Continue Troubleshooting.

Q7: Is the Diesel-Burner's Flame Sensorfunctioning properly?In order to determine if the Flame Sensor isfunctioning properly, reference Section 8.4and perform the Flame Sensor's "ComponentTest".A: If the Flame Sensor is not functioning

properly:The Flame Sensor must be replaced,reference Section 8.4 for replace-ment instructions.

If the Flame Sensor is functioning prop-erly:

Continue Troubleshooting.

Q8: Is the Diesel-Burner's Fuel Pump function-ing properly?In order to determine if the Fuel Pump isfunctioning properly, reference Section 8.8and perform the Fuel Pump's "ComponentTest".A: If the Fuel Pump is not functioning prop-

erly:The Fuel Pump must be replaced,reference Section 8.8 for replace-ment instructions.

If the Fuel Pump is functioning properly:See the "NOTE" below.

Section 7: Troubleshooting

Section 7.2,continued

NOTE: If the Hydro-Hot still does not ignite afterperforming all of the listed checks, contact ourTechnical Department at 1-800-685-4298 foradditional assistance.

Section 7.2,continued

Page 21

Section 7.3

After turning the Diesel switch ON:

TS3: The Hydro-Hot's Diesel-Burner ignitesafter several starting attempts.

NOTES:A. It is ideal to have the Hydro-Hot's Fuel Filter

replaced yearly, reference Section 8.1. Aplugged Fuel Filter will not allow the Diesel-Burner to operate properly. Also, beforeproceeding to the following procedures,be sure to check that the vehicle's fueltank has a sufficient level of fuel.

B. In order to perform the following procedures,it is necessary to detach the Diesel-BurnerHead from the Hydro-Hot. Be sure toreference Section 8.2 for detaching andreattaching instructions.

Q1: Is the Diesel-Burner's Fuel Nozzle function-ing properly?In order to determine if the Fuel Nozzle isfunctioning properly, reference Section 8.6and perform the Fuel Nozzle's "ComponentTest".A: If the Fuel Nozzle is not functioning

properly:The Fuel Nozzle must be replaced,reference Section 8.6 for replacementinstructions.

If the Fuel Nozzle is functioning properly:Continue Troubleshooting.

Page 25: Hydro-Hot Shop Manual Combined - myrvworks.com · 12 Volt-DC Battery Connections will seriously damage the Electronic Controller. Field Wiring Component Wiring Connections JP 3 JP

Hydro-Hot Hydronic Heating System Shop Manual 07/03R

Diesel-BurnerControl

Unit

Diesel-BurnerHead

Section 7: Troubleshooting

IgnitionElectrodes Photo Disc

Flame Sensor

Fuel Pump

Fuel Solenoid

FuelNozzle

ControlUnit

Ignition Coil

Section 7.3,continued

Page 22

Q2: Is the Diesel-Burner's Flame Sensor func-tioning properly?In order to determine if the Flame Sensor isfunctioning properly, reference Section 8.4and perform the Flame Sensor's "ComponentTest".A: If the Flame Sensor is not functioning

properly:The Flame Sensor must be replaced,reference Section 8.4 for replace-ment instructions.

If the Flame Sensor is functioning properly:Continue Troubleshooting.

Q3: Are the Diesel-Burner's Ignition Electrodesin good condition and properly adjusted?In order to determine if the Ignition Electrodesare in good condition and properly adjusted,reference Section 8.5.A: If the Ignition Electrodes are in poor

condition:The Ignition Electrodes must bereplaced, reference Section 8.5 forreplacement instructions.

If the Ignition Electrodes are not properlyadjusted:

Adjust the Ignition Electrodes,reference Section 8.5 for adjustmentinstructions.

If the Ignition Electrodes are both in goodcondition and properly adjusted:

Continue Troubleshooting.

Q4: Is the Diesel-Burner's Fuel Pump function-ing properly?In order to determine if the Fuel Pump isfunctioning properly, reference Section 8.8and perform the Fuel Pump's "ComponentTest".A: If the Fuel Pump is not functioning

properly:The Fuel Pump must be replaced,reference Section 8.8 for replace-ment instructions.

If the Fuel Pump is functioning properly:

Section 7.3,continued

Page 26: Hydro-Hot Shop Manual Combined - myrvworks.com · 12 Volt-DC Battery Connections will seriously damage the Electronic Controller. Field Wiring Component Wiring Connections JP 3 JP

Hydro-Hot Hydronic Heating System Shop Manual 07/03R

Section 7.3,continued

Section 7: Troubleshooting

Continue Troubleshooting.

Q5: Is the Diesel-Burner's Fuel Supply Systemfunctioning properly?Quick Check - With the Diesel-Burner ignited,listen for constant sputtering from the Hydro-Hot's exhaust system.A: If constant sputtering exists:

Continue Troubleshooting.If constant sputtering does not exist:

Proceed to Q6.

NOTE: Inspect the clear bowl of the Fuel Filterfor water. If water exists, be sure to purge theHydro-Hot's entire fuel system prior to replacingthe Fuel Filter. Attempt heater restart.

a. Clamp off and remove the Hydro-Hot's FuelReturn Line, reference Figure 1. Now attacha short piece of fuel line to the Hydro-Hot'sFuel Return Port and place the other end in acontainer of diesel fuel. Remove the clampand ensure that the fuel line is completelysubmersed in the fuel and then turn the Dieselswitch ON. Are air bubbles visible in thecontainer of fuel when the Diesel-Burner isoperating?A: If air bubbles are not visible:

Proceed to Q6.If air bubbles are visible:

You will need to inspect the fuelsystem (supply side) for air leaks.Therefore, be sure to perform theinspections listed below until the airleak has been detected:1. Inspect the fuel system (supply

side) from the vehicle's fuel tankto the Diesel-Burner. Inspect thefuel connections at the Hydro-Hot,Diesel-Burner, and at the vehicle'sfuel tank for looseness. Tighten ifnecessary. Also, check that allFuel Filter Head fittings are se-curely tightened; see the "NOTE"at the top left-hand side of thefollowing page.

2

1

4

3

output toHydro-Hot’s Fuel

"Supply" Portinputfrom Fuel Tank /

fuel pick-up

Fuel Filter

TOP VIEW:of Fuel Filter Head

Plug

Plug

RETURN PORT:from Hydro-Hot’s

"Return" Port

SUPPLY PORT:to Hydro-Hot’s

Fuel Filter

dedicatedfuel pick-up

Fuel Pick-up Pipe Illustration

Section 7.3,continued

Page 23

Page 27: Hydro-Hot Shop Manual Combined - myrvworks.com · 12 Volt-DC Battery Connections will seriously damage the Electronic Controller. Field Wiring Component Wiring Connections JP 3 JP

Hydro-Hot Hydronic Heating System Shop Manual 07/03R

Section 7.3,continued

Section 7: Troubleshooting

NOTE: Be sure to check that each fitting at theFuel Filter Head contains thread sealant. Afitting without thread sealant could result in anair leak. Be sure to clamp off both fuel lines atthe filter head prior to any fitting removal. Iffittings are removed and reinstalled, be sure toremove the fuel line clamps prior to attempting aheater restart. Failure to do so could result inserious damage to the Diesel-Burner's FuelPump.

2. Once the potential air leak hasbeen discovered and corrected,reattach the Hydro-Hot's FuelReturn Line and attempt heaterrestart. Does the Hydro-Hot's ex-haust system still sputter?

If the exhaust system is still sputtering:Perform the air leak inspectionsagain, until all air leaks have beendiscovered and corrected.

Q6: Is the Diesel-Burner's Control Unit func-tioning properly?In order to determine if the Control Unit isfunctioning properly, reference Section 8.11and perform the Control Unit's "ComponentTest".A: If the Control Unit is not functioning

properly:The Control Unit must be replaced,reference Section 8.11 for replace-ment instructions.

If the Control Unit is functioning properly:Continue Troubleshooting.

Q7: Is the Diesel-Burner's Ignition Coil func-tioning properly?In order to determine if the Ignition Coil isfunctioning properly, reference Section 8.10and perform the Ignition Coil's "ComponentTest".A: If the Ignition Coil is not functioning prop-

erly:The Ignition Coil must be replaced,

Section 7.3,continued

Page 24

reference Section 8.10 for replace-ment instructions.

If the Ignition Coil is functioning properly:See the "NOTE" below.

NOTE: If the Hydro-Hot still does not igniteafter several starting attempts and all of thelisted checks were performed, contact ourTechnical Department at 1-800-685-4298 foradditional assistance.

IgnitionElectrodes Photo Disc

Flame Sensor

Fuel Pump

Fuel Solenoid

FuelNozzle

ControlUnit

Ignition Coil

Page 28: Hydro-Hot Shop Manual Combined - myrvworks.com · 12 Volt-DC Battery Connections will seriously damage the Electronic Controller. Field Wiring Component Wiring Connections JP 3 JP

Hydro-Hot Hydronic Heating System Shop Manual 07/03R

2

1

4

3

output toHydro-Hot’s Fuel

"Supply" Portinputfrom Fuel Tank /

fuel pick-up

Fuel Filter

TOP VIEW:of Fuel Filter Head

Plug

Plug

RETURN PORT:from Hydro-Hot’s

"Return" Port

SUPPLY PORT:to Hydro-Hot’s

Fuel Filter

dedicatedfuel pick-up

Fuel Pick-up Pipe Illustration

After turning the Diesel switch ON:

TS4: The Hydro-Hot's exhaust system sputters.

NOTE: Before proceeding to the followingprocedures, be sure to check that the vehicle'sfuel tank has a sufficient level of fuel.

Q1: Is the Diesel-Burner's Fuel Nozzle func-tioning properly?In order to determine if the Fuel Nozzle isfunctioning properly, reference Section 8.6and perform the Fuel Nozzle's "ComponentTest".A: If the Fuel Nozzle is not functioning

properly:The Fuel Nozzle must be replaced,reference Section 8.6 for replace-ment instructions.

If the Fuel Nozzle is functioning properly:Continue Troubleshooting.

Q2: Is the Diesel-Burner's Fuel Supply Systemfunctioning properly?Quick Check - With the Diesel-Burnerignited, listen for constant sputtering from theHydro-Hot's exhaust system.A: If constant sputtering exists:

Continue Troubleshooting.

NOTE: Inspect the clear bowl of the Fuel Filterfor water. If water exists, be sure to purge theHydro-Hot's entire fuel system prior to replacingthe Fuel Filter. Attempt heater restart.

a. Clamp off and remove the Hydro-Hot's FuelReturn Line, reference Figure 1. Now attacha short piece of fuel line to the Hydro-Hot'sFuel Return Port and place the other end in acontainer of diesel fuel. Remove the clampand ensure that the fuel line is completelysubmersed in the fuel and then turn theDiesel switch ON. Are air bubbles visible inthe container of fuel when the Diesel-Burneris operating?A: If air bubbles are not visible:

See the last "NOTE" in this section(Section 7.4).

Section 7.4,continued

Section 7.4

Section 7: Troubleshooting

Page 25

Page 29: Hydro-Hot Shop Manual Combined - myrvworks.com · 12 Volt-DC Battery Connections will seriously damage the Electronic Controller. Field Wiring Component Wiring Connections JP 3 JP

Hydro-Hot Hydronic Heating System Shop Manual 07/03R

If air bubbles are visible:You will need to inspect the fuelsystem (supply side) for air leaks.Therefore, be sure to perform theinspections listed below until the airleak has been detected:1. Inspect the fuel system (supply

side) from the vehicle's fuel tankto the Diesel-Burner. Inspect thefuel connections at the Hydro-Hot, Diesel-Burner, and at thevehicle's fuel tank for looseness.Tighten if necessary. Also, checkthat all Fuel Filter Head fittingsare securely tightened, see the"NOTE" below.

NOTE: Be sure to check that each fitting at theFuel Filter Head contains thread sealant. Afitting without thread sealant could result in anair leak. Be sure to clamp off both fuel lines atthe filter head prior to any fitting removal. Iffittings are removed and reinstalled, be sure toremove both clamps prior to attempting aheater restart. Failure to do so could result inserious damage to the Diesel-Burner's FuelPump.

2. Once the potential air leak hasbeen discovered and corrected,reattach the Hydro-Hot's FuelReturn Line and attempt heaterrestart. Does the Hydro-Hot's ex-haust system still sputter?

If the exhaust system is still sputtering:Perform the air leak inspectionsagain, until all air leaks have beendiscovered and corrected.

NOTE: If the Hydro-Hot's exhaust system stillsputters after performing all of the listed checks,contact our Technical Department at 1-800-685-4298 for additional assistance.

Section 7.4,continued

Section 7: Troubleshooting

Section 7.4,continued

Page 26

2

1

4

3

output toHydro-Hot’s Fuel

"Supply" Portinputfrom Fuel Tank /

fuel pick-up

Fuel Filter

TOP VIEW:of Fuel Filter Head

Plug

Plug

RETURN PORT:from Hydro-Hot’s

"Return" Port

SUPPLY PORT:to Hydro-Hot’s

Fuel Filter

dedicatedfuel pick-up

Fuel Pick-up Pipe Illustration

Page 30: Hydro-Hot Shop Manual Combined - myrvworks.com · 12 Volt-DC Battery Connections will seriously damage the Electronic Controller. Field Wiring Component Wiring Connections JP 3 JP

Hydro-Hot Hydronic Heating System Shop Manual 07/03R

IgnitionElectrodes Photo Disc

Flame Sensor

Fuel Pump

Fuel Solenoid

FuelNozzle

ControlUnit

Ignition Coil

Diesel-BurnerControl

Unit

Diesel-BurnerHead

After turning the Diesel switch ON:

TS5: The Hydro-Hot's exhaust system pro-duces white smoke after ignition.

Q1: Is the Diesel-Burner's Fuel Nozzle func-tioning properly?In order to determine if the Fuel Nozzle isfunctioning properly, reference Section 8.6and perform the Fuel Nozzle's "ComponentTest".A: If the Fuel Nozzle is not functioning

properly:The Fuel Nozzle must be replaced,reference Section 8.6 for replacementinstructions.

If the Fuel Nozzle is functioning properly:Continue Troubleshooting.

Q2: Is the Diesel-Burner's Fuel Pump produc-ing the proper pressure?In order to determine if the Fuel Pump isproducing the proper pressure, referenceSection 8.8 and perform the Fuel Pump's"Fuel Pressure Adjustment Check".A: If the Fuel Pump is not producing the

correct pressure:Adjust the fuel pressure to 145 psi.

If the Fuel Pump is producing the correctpressure:

Continue Troubleshooting.

NOTE: Be sure to check that the IgnitionElectrode's Retaining Clamp Bolt has not beenovertightened, reference Figure 16. Overtighten-ing can result in a bound-up (i.e. rigid) PhotoDisc. Not allowing the Photo Disc to float freely(i.e. a loose fit) will cause poor combustion andresult in a smoky exhaust. If a tight Photo Discexists, reference Section 8.5 and perform the"Ignition Electrode Adjustment Procedure".

Q3: Is the Diesel-Burner's Fuel Supply Systemfunctioning properly?Quick Check - With the Diesel-Burnerignited, look for constant white smoke fromthe Hydro-Hot's exhaust system.A: If constant white smoke exists:

Continue Troubleshooting.

Section 7.5 Section 7.5,continued

Section 7: Troubleshooting

Page 27

Page 31: Hydro-Hot Shop Manual Combined - myrvworks.com · 12 Volt-DC Battery Connections will seriously damage the Electronic Controller. Field Wiring Component Wiring Connections JP 3 JP

Hydro-Hot Hydronic Heating System Shop Manual 07/03R

NOTE: Inspect the clear bowl of the Fuel Filterfor water. If water exists, be sure to purge theHydro-Hot's entire fuel system prior to replacingthe Fuel Filter. Attempt heater restart.

a. Clamp off and remove the Hydro-Hot's FuelReturn Line, reference Figure 1. Now attacha short piece of fuel line to the Hydro-Hot'sFuel Return Port and place the other end in acontainer of diesel fuel. Remove the clampand ensure that the fuel line is completelysubmersed in the fuel and then turn theDiesel switch ON. Are air bubbles visible inthe container of fuel when the Diesel-Burneris operating?A: If air bubbles are not visible:

Proceed to Q6.If air bubbles are visible:

You will need to inspect the fuelsystem (supply side) for air leaks.Therefore, be sure to perform theinspections listed below until the airleak has been detected:1. Inspect the fuel system (supply

side) from the vehicle's fuel tankto the Diesel-Burner. Inspect thefuel connections at the Hydro-Hot, Diesel-Burner, and at thevehicle's fuel tank for looseness.Tighten if necessary. Also, checkthat all Fuel Filter Head fittingsare securely tightened, see the"NOTE" below.

NOTE: Be sure to check that each fitting at theFuel Filter Head contains thread sealant. Afitting without thread sealant could result in anair leak. Be sure to clamp off both fuel lines atthe filter head prior to any fitting removal. Iffittings are removed and reinstalled, be sure toremove both clamps prior to attempting aheater restart. Failure to do so could result inserious damage to the Diesel-Burner's FuelPump.

Section 7: Troubleshooting

Section 7.5,continued

Section 7.5,continued

Page 28

2

1

4

3

output toHydro-Hot’s Fuel

"Supply" Portinputfrom Fuel Tank /

fuel pick-up

Fuel Filter

TOP VIEW:of Fuel Filter Head

Plug

Plug

RETURN PORT:from Hydro-Hot’s

"Return" Port

SUPPLY PORT:to Hydro-Hot’s

Fuel Filter

dedicatedfuel pick-up

Fuel Pick-up Pipe Illustration

Page 32: Hydro-Hot Shop Manual Combined - myrvworks.com · 12 Volt-DC Battery Connections will seriously damage the Electronic Controller. Field Wiring Component Wiring Connections JP 3 JP

Hydro-Hot Hydronic Heating System Shop Manual 07/03R

Heating ZonesStatus

#5

#4

#3

#2

#1

Electric HeatingElement Status

Low Voltage

Reset

EmergencyCutoff

Hydro-HotHeating Status

Engine PreheatPump

ElectronicController

Low BatteryVoltage Fault

Low TempCutoff Status

Overload Fault

CirculationPump #2

CirculationPump #1

Stir Pump

Diesel-BurnerStatus

TM

�� ������������� ���R

Section 7: Troubleshooting

Page 29

2. Once the potential air leak hasbeen discovered and corrected,reattach the Hydro-Hot's FuelReturn Line and attempt heaterrestart. Does the Hydro-Hot's ex-haust system still sputter?

If the exhaust system is still sputtering:Perform the air leak inspectionsagain, until all air leaks have beendiscovered and corrected.

NOTE: If the Hydro-Hot's exhaust system stillproduces white smoke after performing all of thelisted checks, contact our Technical Departmentat 1-800-685-4298 for additional assistance.

After turning the Diesel switch ON:

TS6: The Hydro-Hot's exhaust system pro-duces black smoke after ignition.

Q1: Is the Electronic Controller's Low BatteryVoltage Fault light illuminated?A: If YES:

Perform each of the followingprocedures as necessary until theproblem is resolved.

If NO:Proceed to Q2.

a. Remove the Electronic Controller's Faceplate.Check the DC battery voltage level at thesupply batteries and at the ElectronicController's Battery Connections, referenceFigure 3. Both voltage readings should bebetween 11.5 and 14.0 volts.A: If the voltage level is within specs:

Continue troubleshooting.If the voltage level is out of specs:

Recharge and/or replace batteries, ifnecessary.

Section 7.6

By Vehicle Systems

Diesel Electric EnginePreheat

Diesel-Burner’sIndicator

Light

TM

�� ������������� ���R

Electronic ControllerFaceplate

Section 7.6,continued

Section 7.5,continued

Page 33: Hydro-Hot Shop Manual Combined - myrvworks.com · 12 Volt-DC Battery Connections will seriously damage the Electronic Controller. Field Wiring Component Wiring Connections JP 3 JP

Hydro-Hot Hydronic Heating System Shop Manual 07/03R

Diesel-BurnerControl

Unit

Diesel-BurnerHead

IgnitionElectrodes Photo Disc

Flame Sensor

Fuel Pump

Fuel Solenoid

FuelNozzle

ControlUnit

Ignition Coil

Section 7.6,continued

Section 7.6,continued

Section 7: Troubleshooting

Page 30

b. Reset the Electronic Controller's Low VoltageReset (button) on the Electronic Controller(this can be accomplished by using a thinstraight object to access the reset buttonthrough the small hole in the faceplate).Continue to read the voltage level at theElectronic Controller's Battery Connec-tions and then turn the Diesel switch ON.Under load, is the voltage level within 0.5volts of the supply batteries voltage?A: If YES:

See the first "NOTE" below.If NO:

Load-test the supply batteries,inspect battery wiring for damageand/or loose connections, andensure that all of the Hydro-Hot'selectrical motors are operatingnormally when under load.

NOTE: If after testing and correcting the batterysystem, the Low Battery Voltage Fault indicatorlight continues to illuminate, and/or if the LowVoltage Reset (button) will not reset, theElectronic Controller must be replaced.Please contact our Technical Department at 1-800-685-4298 for assistance.

NOTE: In order to perform some of the follow-ing procedures it may be necessary to detachthe Diesel-Burner Head from the Hydro-Hot.Therefore, be sure to reference Section 8.2 fordetaching and reattaching instructions.

Q2: Is the Diesel-Burner's Fuel Nozzle func-tioning properly?In order to determine if the Fuel Nozzle isfunctioning properly, reference Section 8.6and perform the Fuel Nozzle's "ComponentTest".A: If the Fuel Nozzle is not functioning

properly:The Fuel Nozzle must be replaced,reference Section 8.6 for replace-ment instructions.

Page 34: Hydro-Hot Shop Manual Combined - myrvworks.com · 12 Volt-DC Battery Connections will seriously damage the Electronic Controller. Field Wiring Component Wiring Connections JP 3 JP

Hydro-Hot Hydronic Heating System Shop Manual 07/03R

If the Fuel Nozzle is functioning properly:Continue Troubleshooting.

Q3: Is the Diesel-Burner's Motor operating atthe proper RPM speed?In order to determine if the Motor is operatingproperly, reference Section 8.3 and performthe Motor's "RPM Test".A: If the Motor is not operating at the proper

RPM:The Motor must be replaced, refer-ence Section 8.3 for replacementinstructions.

If the Motor is operating at the properRPM:

Continue Troubleshooting.

Q4: Is the Diesel-Burner's Combustion AirIntake adjusted properly?A: See the "NOTE" below.

NOTE: Inorder to determine if the Diesel-Burner's Combustion Air Intake is adjustedproperly, a CO2 Gas-Analyzer will be required,reference the illustration on this page. Also,reference Section 11 for the Bacharach FyriteCO2 Analyzer's part number information, ifnecessary.

a. When using the Bacharach Fyrite CO2 Ana-lyzer, turn the Diesel switch ON and allow theDiesel-Burner to ignite. Then perform thefollowing procedures:

1. Place the small end of the CO2

Analyzer's suction hose into theHydro-Hot's Exhaust Pipe.

2. Place the round plunger connec-tion of the suction hose on theCO2 Analyzer's "Plunger". Pressdown on the suction hose, withthe palm of your hand, so that theCO2 Analyzer's Plunger" is fullycompressed. This will allow asample of the Hydro-Hot's ex-haust to enter the CO2 Analyzer.

Section 7.6,continued

Section 7.6,continued

Section 7: Troubleshooting

Page 31

CO -2 + CO2

Combustion Air Intake Adjustment

13

12

11

10

9

8

7

20 24 2622 2810 12 14

DC Voltage Level

V-

Vol %

CO2

CO2 - Value Chart

Percentage

CO2 GasAnalyzer

#3 - Plunger#4 - Rubber Ball

Page 35: Hydro-Hot Shop Manual Combined - myrvworks.com · 12 Volt-DC Battery Connections will seriously damage the Electronic Controller. Field Wiring Component Wiring Connections JP 3 JP

Hydro-Hot Hydronic Heating System Shop Manual 07/03R

Fuel Pump is producing the properpressure. In order to determine if theFuel Pump is producing the properpressure, reference Section 8.8 andperform the Fuel Pump's "Fuel PressureAdjustment Check".

D. Check and reset the Combustion AirBlower gap, if applicable. In order todetermine if the Combustion Air Blower'sgap is set properly, reference Section 8.9and perform Steps 1-6 and 11-17 of theBearings "Replacement Procedure".

E. See the "NOTE" below.

NOTE: If the Hydro-Hot's exhaust system stillproduces black smoke after performing all ofthe listed checks, contact our Technical Depart-ment at 1-800-685-4298 for additional assis-tance.

Section 7: Troubleshooting

Section 7.6,continued

Section 7.6,continued

Page 32

3. Pump the rubber ball - 18 times.4. Release the suction hose from the

CO2 Analyzer's plunger.5. Turn the CO2 Analyzer upside

down so that the fluid runs to thetop and then turn it right side upagain. Perform this proceduretwice.

6. Place the CO2 Analyzer on a flatsurface and read the CO2 level.

7. The CO2 level should be between10.5 and 11.5 percent (at a nomi-nal 12 volts DC). If the CO2 level isnot within specs, an adjustment ofthe Diesel-Burner's CombustionAir Intake will be necessary,reference the illustration on theprevious page. Once the properCO2 adjustment has been made,be sure to tighten the adjustmentscrew.

NOTE: For temporary high altitude situations(less available oxygen) the CO2 will rise by0.3% CO2 per 1,000 feet of elevation. (e.g. aDiesel-Burner adjusted at sea level shouldregister approximately a 1.5% higher CO2

reading when in Denver, Colorado {5,000above sea level}). If permanently residing in ahigh altitude area, be sure to properly adjustthe Diesel-Burner so that it operates within the10.5% - 11.5% CO2 range.

NOTES: If the proper CO2 - value cannot beobtained, perform each of the following inspec-tions as necessary until the cause has beendetected:

A. Check the rubber Grommets on the topand bottom of the Diesel-Burner Head'scast-aluminum Blower Casing to ensurethey are securely in place.

B. Check the Diesel-Burner Head for properalignment. (torque specification = approx.20-40 in. lbs.), reference Section 8.2.

C. Check to ensure that the Diesel-Burner's

Page 36: Hydro-Hot Shop Manual Combined - myrvworks.com · 12 Volt-DC Battery Connections will seriously damage the Electronic Controller. Field Wiring Component Wiring Connections JP 3 JP

Hydro-Hot Hydronic Heating System Shop Manual 07/03R

Section 7: Troubleshooting

Section 7.7,continued

Page 33

BedroomZone

Cozy III HeatExchanger

BathroomZone

Cozy III HeatExchanger

KitchenCozy III HeatExchanger

Living RoomCozy III HeatExchanger

Fresh WaterTank Zone

Cozy III HeatExchanger

HeatingLoop 2

HeatingLoop 1

Typical Heat ExchangerLocations

Living RoomCozy III HeatExchanger

Living Room /Kitchen Zone

After turning the Diesel switch ON:

TS7: The Hydro-Hot is at operating tempera-ture, but an Interior and/or Fresh WaterTank Heating Zone is not producing heat.

Q1: Is the particular Heating Loop's Circula-tion Pump operating?Quick Check - Remove the Hydro-Hot'sAccess Cover and determine if the problemHeat Exchanger(s) are plumbed with Circula-tion Pump #1 or Circulation Pump #2, refer-ence Figure 1 and the illustration below. Oncethe correct Circulation Pump has been deter-mined, locate and activate the Room Thermo-stat for the particular heating zone. Thisshould activate that particular CirculationPump. Is the Circulation Pump operating?A: If YES:

Check the particular Heating Loopsplumbing system for kinks and/orany other types of flow restrictions.

If NO:Perform each of the following proce-dures as necessary until the problemis resolved.1. Locate the Electronic Controller

and remove the Faceplate.

Section 7.7

2. Locate the Electronic Controller'sJP-3 Plug and then insert theprobes of a DC voltmeter intoPin locations 5 (+) and 6 (-) forCirculation Pump #1, and/or intoPin locations 3 (+) and 4 (-) forCirculation Pump #2, referenceFigure 3. Observe the DC voltagelevel on the voltmeter. Does anominal voltage reading registeron the voltmeter?

A: If YES:The Circulation Pump must bereplaced. Please contact ourTechnical Department at 1-800-685-4298 for assistance.

If NO:The Electronic Controller mustbe replaced. Please contactour Technical Department at 1-800-685-4298 for assistance.

Page 37: Hydro-Hot Shop Manual Combined - myrvworks.com · 12 Volt-DC Battery Connections will seriously damage the Electronic Controller. Field Wiring Component Wiring Connections JP 3 JP

Hydro-Hot Hydronic Heating System Shop Manual 07/03R

Yellow wires

Black wires

ATOFuse

Yellow wire

Yellow wire

Black wires

Heating ZonesStatus

#5

#4

#3

#2

#1

Electric HeatingElement Status

Low Voltage

Reset

EmergencyCutoff

Hydro-HotHeating Status

Engine PreheatPump

ElectronicController

Low BatteryVoltage Fault

Low TempCutoff Status

Overload Fault

CirculationPump #2

CirculationPump #1

Stir Pump

Diesel-BurnerStatus

TM

�� ������������� ���R

Page 34

Electronic ControllerFaceplate

Section 7.8,continued

After turning the Diesel switch ON:

TS8: The Hydro-Hot is at operating tempera-ture, but the fans of an Interior and/orFresh Water Tank Heat Exchangers arenot operating.

Q1: Is the Electronic Controller's Low TempCutoff Status light illuminated?A: If YES:

Perform each of the followingprocedures as necessary until theproblem is resolved.

If NO:Inspect the Heat Exchanger fansand interior Room Thermostat wiringfor loose connections at JP-1 Plug ofthe Electronic Controller, referenceFigure 3.

a. Activate the interior Room Thermostat andthen turn the Diesel switch ON. Remove theHydro-Hot's Access Cover and locate the twoyellow colored wires, which connect to the twoblack wires, reference the illustration on thispage. Disconnect the wires and then connectthe two yellow wires together by utilizing anATO type automotive fuse, again referencethe illustration. Do the Heat Exchanger fansnow operate?A: If YES:

The Low Temp Cutoff Thermostatmay need to be replaced. Pleasecontact our Technical Department at1-800-685-4298 for assistance.

If NO:Perform each of the followingprocedures as necessary until theproblem is resolved.1. Locate the Electronic Controller

and remove the Faceplate.2. Locate the Electronic Controller's

JP-1 Plug and read the DC voltagesignal output, and input, at theparticular interior RoomThermostat's circuit, referenceFigure 3. Is there an output DC

Section 7.8

Section 7: Troubleshooting

Page 38: Hydro-Hot Shop Manual Combined - myrvworks.com · 12 Volt-DC Battery Connections will seriously damage the Electronic Controller. Field Wiring Component Wiring Connections JP 3 JP

Hydro-Hot Hydronic Heating System Shop Manual 07/03R

After turning the Diesel switch ON:

TS9: The Hydro-Hot is at operating tempera-ture, but the domestic hot water system isnot producing hot water.

Q1: Is the Electronic Controller's Stir PumpStatus light illuminated? (reference Figure5)A: If YES:

Perform each of the followingprocedures as necessary until theproblem is resolved.1. Seal all openings that may allow

cool air to enter the open area atthe backside of the Hydro-Hot.

2. Locate the Low-Temp Cutoff Ther-mostat, reference Figure 1. Makesure that the thermostat has notbeen dislodged from the copperline, reference Figure 1.

3. Turn the Diesel switch ON andallow the Hydro-Hot to reach it'smaximum operating temperature.Once the Diesel-Burner hascycled OFF, check the Low-TempCutoff Thermostat for continuity,reference Figures 1 and 3. If nocontinuity is present, the LowTemp Cutoff Thermostat must bereplaced. Please contact ourTechnical Department at 1-800-685-4298 for assistance.

If NO:Check the Hydro-Hot's heatingsolution for the proper antifreeze towater mixture (should be 33% anti-freeze and 67% water). A highconcentration of antifreeze will causea poor domestic hot water perfor-mance.

NOTE: If there is still a lack of hot water afterperforming all of the listed checks, contact ourTechnical Department at 1-800-685-4298 foradditional assistance. Also, be sure to refer-ence the chart on the following page regardingthe Hydro-Hot's Domestic Hot Water System.

voltage signal at the ElectronicController?

A: If YES:The interior Room Thermostat mayneed to be replaced. Please contactour Technical Department at 1-800-685-4298 for assistance.

If NO:The Electronic Controller must bereplaced. Please contact our Techni-cal Department at 1-800-685-4298 forassistance.

Section 7.8,continued

Section 7.9

Section 7: Troubleshooting

Page 35

Page 39: Hydro-Hot Shop Manual Combined - myrvworks.com · 12 Volt-DC Battery Connections will seriously damage the Electronic Controller. Field Wiring Component Wiring Connections JP 3 JP

Section 7: Troubleshooting

Section 7.9,continued

40

0.5 2.52.01.51.0

50

80

70

60

3.0

citsemo

D fo erutarepmeT )gni

mocni .e.i( tupnIto

H-ordyH eht ot reta

W dloC

F

GPM

Estimated flow rate, of domestic cold water, required to maintain an approximate 115 F output temperature of domestic hot water.

(GPM - Gallons per Minute)

The chart below, is a graphical representation of how the Hydro-Hot’s Domestic Hot Water System theoretically performs under varying domestic cold water temperatures.Because each Hydro-Hot has a performance tolerance, this graph should be used as a

general guideline and not as actual domestic hot water performance data.

Notes of interest:

When water is heated to.....156 degrees - Hot water causes a third-degree burn in one second149 degrees - Hot water causes a third-degree burn in two seconds133 degrees - Hot water causes a third-degree burn quickly115-120 degrees - General purpose temperatures107-109 degrees - Average "Hot-Tub" temperatures105 degrees - Average "Shower" temperature

115

Fdo

mes

ticho

t wat

ercu

rve

Page 36

Page 40: Hydro-Hot Shop Manual Combined - myrvworks.com · 12 Volt-DC Battery Connections will seriously damage the Electronic Controller. Field Wiring Component Wiring Connections JP 3 JP

Section 7: Troubleshooting

Section 7.10

After turning the Electric switch ON:

TS10: The Hydro-Hot's 120 VAC Electric Heat-ing Element does not operate (i.e. lack ofhot water and/or interior heat).

Q1: Is the Electronic Controller's ElectricHeating Element Status light illuminated?(reference Figure 5)A: If YES:

Perform each of the following proce-dures as necessary until the problemis resolved.1. Locate the Electronic Controller

and remove the Faceplate.2. Locate the Electronic Controller's

JP-3 Plug and check for DCvoltage at Pin 11 (+) and Pin 12 (-),reference Figure 3.

A: If voltage is present:Check for loose wire connectionsat Pin 11 (+) and Pin 12 (-) of theJP-3 Plug. If the wire connec-tions are in good condition,proceed to Q2.If no voltage is present:Replace the Electronic Controller.Please contact our TechnicalDepartment at 1-800-685-4298 forassistance.

If NO:Perform each of the following proce-dures as necessary until the problemis resolved.1. Locate the Electronic Controller

and remove the Faceplate.2. Locate the Electronic Controller's

JP-2 Plug. Use a jumper wire tomake a connection from theElectric (+) pin to the Electric (-)pin, reference Figure 3. DoesElectronic Controller's ElectricHeating Element Status lightilluminate?

A: If the Electric Heating Element Statuslight illuminates:Check for loose wire connectionsat Electric switch and at the JP-2

Plug's Electric (+) and Electric (-)pins. If connections are in goodcondition, replace the Electricswitch.If the Electric Heating ElementStatus light did not illuminate:Locate the Electronic Controller'sJP-2 Plug and check for DCvoltage at the Electric (+) andElectric (-) pins, reference Figure3.If no voltage is present:Replace the Electronic Controller.Please contact our TechnicalDepartment at 1-800-685-4298 forassistance.

Q2: Has the Hydro-Hot's VAC High-Limit Ther-mostat tripped?

WARNING: Turn the VAC breakerOFF prior to performing the follow-ing checks. Failure to do so mayresult in serious bodily injury (i.e.electrical shock).

Remove the 4 in. x 4 in. Electric HeatingElement Access Panel and locate the VACHigh-Limit Thermostat, reference Figure 1.Check for continuity at the VAC High-LimitThermostat. Is continuity present?A: If YES:

Proceed to Q3.If NO:

Press the red reset button located onthe VAC High-Limit Thermostat.Reset the VAC breaker and then turnthe Electric switch ON.

NOTE: Although the 120 VAC Electric HeatingElement is now functioning, be sure to performthe following steps until the cause for over-heating has been discovered and corrected.Failure to do so could result in another over-heating condition.

Section 7.10,continued

Page 37

Page 41: Hydro-Hot Shop Manual Combined - myrvworks.com · 12 Volt-DC Battery Connections will seriously damage the Electronic Controller. Field Wiring Component Wiring Connections JP 3 JP

Hydro-Hot Hydronic Heating System Shop Manual 07/03R

a. Turn the Diesel and Electric switches ON andallow the Hydro-Hot to reach maximumoperating temperature (i.e. until the Diesel-Burner cycles OFF). Locate both the VACHigh-Limit Thermostat and the VAC / VDCControl Thermostat and check for continuity,reference Figure 1.A: If there is no continuity at the VAC High-

Limit Thermostat, but there is continuity atthe VAC / VDC Control Thermostat:

The VAC / VDC Control Thermostatmust be replaced. Please contactour Technical Department at 1-800-685-4298 for assistance.

If there is continuity at the VAC High-LimitThermostat, but none at the VAC / VDCControl Thermostat:

The overheat condition may havebeen caused by another faultycomponent and no further trouble-shooting is necessary, see the"NOTE" below. Please contact ourTechnical Department at 1-800-685-4298 for additional assistance.

NOTE: If the VDC High-Limit Thermostatcontinues to trip, and no overheating problemswere discovered (i.e. faulty VAC / VDC ControlThermostat), it may be that the VDC High-LimitThermostat is not operating properly and it mayneed to be replaced.

Q3: Is VAC power being supplied to the VACElement Relay?

WARNING: The following checksneed to be performed with themotorhome connected to VACpower. Be sure to use extremecaution when performing eachcheck, as 120 VAC power will bepresent at each of the electricalcomponents. Failure to do so mayresult in serious bodily injury (i.e.electrical shock).

Turn the Electric switch ON. Locate the VACElement Relay in the 4 in. x 4 in. junction box,reference Figure 1. Check for AC voltage atthe Black (+) wire ("120 VAC Power Supply")connection at the AC Element Relay, refer-ence Figure 3. For a common ground, usethe White wire connection at the 120 VACElectric Heating Element. Is voltage present?A: If YES:

Proceed to Q4.If NO:

Check for loose wire connectionsat the motorhome's VAC junctionbox. If the wire connections are ingood condition, please contact ourTechnical Department at 1-800-685-4298 for additional assistance.

Q4: Is VAC Element Relay functioning prop-erly?

WARNING: The following checksneed to be performed with themotorhome connected to VACpower. Be sure to use extremecaution when performing eachcheck, as 120 VAC power will bepresent at each of the electricalcomponents. Also, be sure todisconnect VAC power prior toreplacing any electrical compo-nents. Failure to do so may resultin serious bodily injury (i.e. electri-cal shock).

NOTE: Inspect the VAC Element Relay fordamage. If visual signs of damage exist, therelay must be replaced.

Turn the Electric switch ON. Locate the VACElement Relay in the 4 in. x 4 in. junction box.Check for AC voltage at the Black (+) wire(from the VAC High-Limit Thermostat) con-nection at the AC Element Relay, referenceFigure 3. For a common ground, use the

Section 7: Troubleshooting

Section 7.10,continued

Section 7.10,continued

Page 38

Page 42: Hydro-Hot Shop Manual Combined - myrvworks.com · 12 Volt-DC Battery Connections will seriously damage the Electronic Controller. Field Wiring Component Wiring Connections JP 3 JP

Hydro-Hot Hydronic Heating System Shop Manual 07/03R

White wire connection at the 120 VAC ElectricHeating Element. Is voltage present?A: If YES:

Proceed to Q5.If NO:

The VAC Element Relay must bereplaced. Please contact out Techni-cal Department at 1-800-685-4298 forassistance.

Q5: Is 120 VAC Electric Heating Elementfunctioning properly?

WARNING: The following checksneed to be performed with themotorhome connected to VACpower. Be sure to use extremecaution when performing eachcheck, as 120 VAC power will bepresent at each of the electricalcomponents. Also, be sure todisconnect VAC power prior toreplacing any electrical compo-nents. Failure to do so may resultin serious bodily injury (i.e. electri-cal shock).

Disconnect the motorhome from VAC shorepower. Locate the 120 VAC Electric HeatingElement in the 4 in. x 4 in. junction box.Remove the White (common) wire from the120 VAC Electric Heating Element. Check forcontinuity at the Black (+) wire and at theterminal where the White (common) wire wasremoved. Is continuity present?A: If YES:

See the "NOTE" on the top right-hand side of this page.

If NO:The 120 VAC Electric Heating Ele-ment must be replaced. Pleasecontact out Technical Department at1-800-685-4298 for assistance.

NOTE: If the 120 VAC Electric Heating Elementstill does not seem to operate after performingall of the listed checks, contact our TechnicalDepartment at 1-800-685-4298 for additionalassistance.

Section 7.10,continued

Section 7.10,continued

Section 7: Troubleshooting

After turning the Engine Preheat switch ON:

TS11: The Hydro-Hot's Engine Preheat Systemdoes not preheat the engine.

NOTE: The Diesel or Electric switch must beactivated, along with the Engine Preheatswitch, prior to performing the following checks.

Q1: Is the Electronic Controller's EnginePreheat Pump light illuminated? (referenceFigure 5)A: If YES:

Perform each of the following proce-dures as necessary until the prob-lem is resolved.1. Locate the Electronic Controller

and remove the Faceplate.2. Locate the Electronic Controller's

JP-3 Plug and check for DCvoltage at Pin 7 (+) and Pin 8 (-),reference Figure 3.

A: If voltage is present:Check for loose wire connectionsat Pin 7 (+) and Pin 8 (-) of the JP-3 Plug. Also, check the wire con-nections at the Engine PreheatPump. If all connections are ingood condition, listen and feel theEngine Preheat Pump to ensurethat it is operating, referenceFigure 1. If the Engine PreheatPump is not operating, it must bereplaced.

Section 7.11

Page 39

Page 43: Hydro-Hot Shop Manual Combined - myrvworks.com · 12 Volt-DC Battery Connections will seriously damage the Electronic Controller. Field Wiring Component Wiring Connections JP 3 JP

Hydro-Hot Hydronic Heating System Shop Manual 07/03R

Section 7: Troubleshooting

If no voltage is present:Replace the Electronic Controller.

If NO:Perform each of the following proce-dures as necessary until the problemis resolved.1. Locate the Electronic Controller

and remove the Faceplate.2. Locate the Electronic Controller's

JP-2 Plug. Use a jumper wire tomake a connection from thePreheat (+) pin to the Preheat (-)pin, reference Figure 3. DoesElectronic Controller's EnginePreheat Pump light illuminate?

A: If the Engine Preheat Pump lightilluminates:Check for loose wire connectionsat Engine Preheat switch and atthe JP-2 Plug's Preheat (+) andPreheat (-) pins, reference Figure3. If connections are in goodcondition, replace the EnginePreheat switch.If the Engine Preheat Pump light didnot illuminate:Locate the Electronic Controller'sJP-2 Plug and check for DCvoltage at the Preheat (+) andPreheat (-) pins, reference Figure3.If no voltage is present:Replace the Electronic Controller.Please contact our TechnicalDepartment at 1-800-685-4298 forassistance.If voltage is present:See "NOTE" below.

NOTE: If the Engine Preheat Pump still doesnot seem to operate after performing all of thelisted checks, contact our Technical Departmentat 1-800-685-4298 for additional assistance.

Section 7.11,continued

Page 40

Page 44: Hydro-Hot Shop Manual Combined - myrvworks.com · 12 Volt-DC Battery Connections will seriously damage the Electronic Controller. Field Wiring Component Wiring Connections JP 3 JP

Hydro-Hot Hydronic Heating System Shop Manual 07/03R

Fuel Nozzle(0.35 GPH)

CombustionChamber

Fuel Filter(10 Micron)

small orifice

8.1 General Recommended Maintenance

Section 8: Diesel-Burner Service, Maintenance, and Repair Information

GeneralRecommendedMaintenance

Figure 9

Monthly

Check the Hydro-Hot's water and antifreeze solution to ensure that it is atthe proper level. Do this by visually checking the coolant level in the Hydro-Hot's Expansion Tank, reference Figure 1. This should be checked onlywhen the Hydro-Hot is at maximum operating temperature (i.e. when theDiesel-Burner cycles OFF), "HOT".

WARNING: When the Hydro-Hot is at maximum operating temperature(HOT), DO NOT loosen the Radiator Cap. If removed, scalding by hotvapor or coolant could result.

If the coolant needs replenishing, fill the Hydro-Hot's Expansion Tank to theFULL HOT level mark. Be sure to reference the Hydro-Hot "Owner'sManual" for the proper antifreeze type and mixture. If coolant frequentlyneeds replenishing, please contact our Technical Department at 1-800-685-4298 for assistance.

Annually

WARNING: Before cleaning or servicing, disconnect all power sup-plies.

To keep your Hydro-Hot running smoothly, it is ideal to have the Diesel-Burner tuned-up annually. A tune-up should consist of a new Fuel Nozzleand Fuel Filter, along with a thorough cleaning of the Combustion Chamber,if necessary (reference Figure 9). To ensure maximum Diesel-Burnerperformance, always use the recommended Fuel Nozzle and Fuel Filter(i.e. 10 Micron) when replacing these parts. Reference Section 10 forspare parts information.

NOTE: Be sure to use care when handling the Fuel Nozzle. Oils and/orsmall dust or dirt particles from your hands may plug the nozzle's smallorifice. A partially plugged orifice will restrict fuel flow, which will affectthe combustion process of the Diesel-Burner (i.e. excessive smoking).

CAUTION: Operating the Hydro-Hot's Diesel-Burner or the 120 VACElectric Heating Element, without the water and antifreeze solution, willcause serious damage to the heater.

Page 41

Page 45: Hydro-Hot Shop Manual Combined - myrvworks.com · 12 Volt-DC Battery Connections will seriously damage the Electronic Controller. Field Wiring Component Wiring Connections JP 3 JP

Page 42

Section 8: Diesel-Burner Service, Maintenance, and Repair Information

Detaching andReattaching theDiesel-BurnerHead

8.2 Detaching and Reattaching the Diesel-Burner Head

WARNING: Be sure to turn the Diesel switch OFF and disconnect theB-Plug Harness from the Diesel-Burner's Control Unit prior to detachingthe Diesel-Burner Head, reference Figures 8 and 26. Failure to do somay result in the ignition of the Diesel-Burner and serious bodily injury.

1. Loosen the two Eye-Bolt Nuts and swing the Eye-Bolts out of theway, reference Figure 10.

2. With both hands, carefully pull the Diesel-Burner Head away fromthe Hydro-Hot (approximately 4-5 inches). Please note that youmay have to lift the Diesel-Burner Head slightly while pulling it awayfrom the Hydro-Hot.

3. Rotate the Diesel-Burner Head upward until all the internal compo-nents are visible.

CAUTION: When reattaching the Diesel-Burner Head, be sure toproperly align the Diesel-Burner Head before tightening the Eye BoltNuts. Also, visually inspect all of the rubber Grommets on the top andbottom of the Diesel-Burner Head's cast-aluminum Blower Casing toensure they are in place. DO NOT over tighten the Eye-Bolt Nuts(torque specification = approx. 20-40 in. lbs.). An improper alignmentand/or an over tightening of the Eye-Bolt Nuts can cause damage tothe Diesel-Burner Head's cast-aluminum Blower Casing, referenceFigure 10.

Figure 10

Grommets

BlowerCasing

Eye-Boltsand Nuts

DieselFuel Return

DieselFuel Supply

Diesel-BurnerHead

Page 46: Hydro-Hot Shop Manual Combined - myrvworks.com · 12 Volt-DC Battery Connections will seriously damage the Electronic Controller. Field Wiring Component Wiring Connections JP 3 JP

Page 43

Figure 11

Section 8: Diesel-Burner Service, Maintenance, and Repair Information

Motor 8.3 Motor

Function: The Motor drives the Combustion Air Blower and the FuelPump.

NOTE: In order to perform the following procedures, it may be neces-sary to detach and reattach the Diesel-Burner Head. Be sure to refer-ence Section 8.2, Page 42 for detaching and reattaching instructions.

Component Test: Locate the Control Unit's C-Plug and insert the probesof a DC voltmeter into the C-2 (+) and C-5 (-) locations, reference Figure11. Turn the Diesel switch ON and observe the voltage level. If a nominalvoltage registers on the voltmeter and the Motor is not operating, inspectthe C-Plug Harness for loose or damaged wire connections. If the C-PlugHarness and connections are in good condition, the Motor must be re-placed, reference the Motor's "Replacement Procedure" on Page 45.

Cleaning Tips / Maintenance: N/A

(+)COM (-)

C-2 ( + ) Motor Circuit (Black Wire)to Diesel-Burner.

C-PlugC-1C-8C-7C-6C-4C-2

C-5

C-5 ( - ) Ground Circuit (Brown Wire), forDiesel-Burner components, to Diesel-Burner.

V 5.21

Page 47: Hydro-Hot Shop Manual Combined - myrvworks.com · 12 Volt-DC Battery Connections will seriously damage the Electronic Controller. Field Wiring Component Wiring Connections JP 3 JP

Hydro-Hot Hydronic Heating System Shop Manual 07/03R

MPR 0054

Black Electrical Tape on Clutch Halves

BlackWire (+) Brown

Wire (-)

Motor

ReflectiveTape

PhotoTachometer

Page 44

Section 8: Diesel-Burner Service, Maintenance, and Repair Information

Motor,continued

Figure 12

Adjustment Procedure: N/A

RPM Test: Disconnect the Ignition Cables from the Ignition Electrodes,reference Figure 16. Remove the four Ignition Coil Screws that secure theIgnition Coil to the Protection Cap, reference Figure 13. Lift the Ignition Coiland disconnect its wires from the C-Plug Harness wires prior to removing.Remove the Protection Cap from the Diesel-Burner so that the Motor andClutch Halves are exposed, reference Figures 12 and 13. Place a fewwraps of black electrical tape around the Clutch Halves and then place asmall piece of reflective tape over the black tape, as illustrated in Figure 12.Disconnect the Motor's Black (+) and Brown (-) wires from the C-PlugHarnesses Black (+) and Brown (-) wires, reference Figures 12 and 13.Connect the Motor's wires directly to a 12 volt DC power supply, referenceFigure 12. Turn the power supply ON and use a photo-tachometer to testfor a proper RPM reading, reference Figure 12. At approximately 12.5 voltsDC, the RPM reading should be 4500 RPM's (+/- 300 RPM's). If theMotor's RPM reading is not within the above specs, the Motor must bereplaced, reference the Motor's "Replacement Procedure" on Page 45.Reference Section 10 for spare part number information.

NOTE: If the Motor's RPM reading is out of specs, or even if withinspecs, be sure to test the Diesel-Burner's Bearings prior to reattachingthe Diesel-Burner Head or replacing the Motor, if applicable. WornBearings can cause lower than normal RPM readings and prematureMotor wear. To properly test for worn Bearings, reference Section 8.9,Page 60 for the Bearings "Function Test".

Page 48: Hydro-Hot Shop Manual Combined - myrvworks.com · 12 Volt-DC Battery Connections will seriously damage the Electronic Controller. Field Wiring Component Wiring Connections JP 3 JP

Hydro-Hot Hydronic Heating System Shop Manual 07/03R Page 45

Replacement Procedure:

1. Remove the four Ignition Coil Screws that secure the Ignition Coil tothe Protection Cap, reference Figure 13. Lift the Ignition Coil todisconnect its wires from the C-Plug Harness wires prior to remov-ing. Remove the Protection Cap from the Diesel-Burner so that theMotor and Clutch Halves are exposed, reference Figures 13 and 14.

2. Remove the three Hex Head Screws that secure the Motor andflange assembly to the Blower Housing, reference Figure 13.Remove the Motor and flange assembly along with the ClutchHalves, reference Figures 13 and 14. Disconnect the Motor's Black(+) and Brown (-) wires from the C-Plug Harness' wires, referenceFigure 13.

NOTE: Inspect the Clutch Halves' for cracks and also ensure that theflat portion in each shaft hole is free of wear and tear. Too much play onthe shaft produces a loud clacking noise. If any cracks or wear aredetected, the Clutch Half must be replaced. Reference the Hydro-Hot's"Parts Manual" for spare parts information.

3. Detach the Motor from the Motor Flange by removing the twoPhillips Head Screws that fasten the two parts together, referenceFigure 13.

NOTES:A: Be sure to test the Diesel-Burner's Bearings prior to reinstalling the

Motor. Worn Bearings can cause lower than normal RPM readingsand premature Motor wear. To properly test for worn Bearings,reference Section 8.9, Page 60 for the Bearings "Function Test"..

B: The Motor must be mounted to the flange with the wires and drainhole pointing downward and the recessed edge of the Motor Flangepointing upward, reference Figure 14. This will ensure a properProtection Cap fit.

4. Reinstall a Clutch Half on both the new Motor's shaft and theCombustion Air Blower's shaft. Attach the Motor and flange assem-bly, with the recessed edge of the Motor Flange in-line with thewiring access slot of the Blower Casing, to the Blower Housing withthe three Hex Head Screws, reference Figure 14.

NOTE: Inspect the Blower Casing's O-Ring for damage or wear prior toreinstalling the Diesel-Burner Head's Protection Cap, reference Figure14. If damage or wear exists, replace the O-Ring. Reference the Hydro-Hot's "Parts Manual" for spare parts information.

5. Connect the Black (+) and Brown (-) wires of the new Motor to theC-Plug Harness' Black (+) and Brown (-) wires, reference Figure 13.Feed the C-Plug Harness' Yellow and Brown wires back through thewiring access hole in the Protection Cap, reference Figure 14.

6. Reinstall the Protection Cap. Reconnect the Black (+) and Brown (-)wires of the Ignition Coil to the C-Plug Harness' Yellow (+) andBrown (-) wires, reference Figure 24. Reinstall the Ignition Coil and

Section 8: Diesel-Burner Service, Maintenance, and Repair Information

Motor,continued

Page 49: Hydro-Hot Shop Manual Combined - myrvworks.com · 12 Volt-DC Battery Connections will seriously damage the Electronic Controller. Field Wiring Component Wiring Connections JP 3 JP

Hydro-Hot Hydronic Heating System Shop Manual 07/03R

Section 8: Diesel-Burner Service, Maintenance, and Repair Information

Motor,continued

Page 46

secure to the Protection Cap with the four Ignition Coil Screws,reference Figure 13.

Figure 13

Figure 14

Page 50: Hydro-Hot Shop Manual Combined - myrvworks.com · 12 Volt-DC Battery Connections will seriously damage the Electronic Controller. Field Wiring Component Wiring Connections JP 3 JP

Hydro-Hot Hydronic Heating System Shop Manual 07/03R Page 47

Section 8: Diesel-Burner Service, Maintenance, and Repair Information

FlameSensor

8.4 Flame Sensor

Function: The Flame Sensor is a photoresistive device which suppliesthe Diesel-Burner's Control Unit with a DC voltage signal when it detectsa flame (i.e. light source).

NOTES:A: In order to perform the following procedures it is necessary to

detach and reattach the Diesel-Burner Head. Be sure to reviewSection 8.2, Page 42 for detaching and reattaching instructions.

B: Be sure to calibrate your ohmmeter prior to checking the FlameSensor for proper resistance values.

Component Test: Locate and detach the Flame Sensor's Green and Bluewires from the C-Plug Harness wires, reference Figure 15. Connect theFlame Sensor's Green and Blue wires to an ohmmeter, reference Figure15. Check resistance by placing a shop rag over the Flame Sensor's glasssurface, to simulate a no flame condition, and then remove the rag (andexpose to a light source) to simulate a flame condition. If the FlameSensor is operating properly, the ohmmeter should register high resistance(i.e. 100K �����when the glass surface is covered, and less than 300 �when exposed to a light source. If these resistance numbers cannot beobtained, the Flame Sensor must be replaced, reference the FlameSensor's "Replacement Procedure" below. Reference Section 10 for spareparts information.

Cleaning Tips / Maintenance: For light dirt, dust, and/or carbon deposits,simply wipe off the Flame Sensor with a soft cloth. Should heavy carbondeposits be present, completely remove the Flame Sensor from the PhotoDisc and clean with brake cleaner, reference Figure 15.

Adjustment Procedure: N/A

Replacement Procedure:

1. Remove the Screw that fastens the Flame Sensor to the Photo Discand detach the sensor's Green and Blue wires from the C-PlugHarness' Green and Violet wires, reference Figure 15.

2. Slide the tab of the new Flame Sensor into the provided slot in thePhoto Disc and secure in place with the screw, reference Figure 15.Connect the Flame Sensor's Green wire to the Green C-PlugHarness wire and the Blue wire to the C-Plug Harness' Violetwire, reference Figure 15.

Page 51: Hydro-Hot Shop Manual Combined - myrvworks.com · 12 Volt-DC Battery Connections will seriously damage the Electronic Controller. Field Wiring Component Wiring Connections JP 3 JP

Page 48

Function: The Diesel-Burner's Ignition Coil (reference Figure 24) pro-duces a high voltage ignition spark across the Ignition Electrodes, whichignites the incoming air / fuel mixture.

NOTE: In order to perform the following procedures it is necessary todetach and reattach the Diesel-Burner Head. Be sure to review Section8.2, Page 42 for detaching and reattaching instructions.

Component Test: N/A

Cleaning Tips / Maintenance: Polish away any carbon deposits that mayhave baked onto the metal tips of the Ignition Electrodes with a scotchbrite pad (or similar), reference Figure 16. If the Ignition Electrode'selectrical insulator (reference Figure 16) is cracked and/or damaged, theIgnition Electrode must be replaced, reference the Ignition Electrode"Replacement Procedure" on Page 49. Reference Section 10 for spareparts information.

NOTE: The Electrode Adjustment Gauge is to used to set the gapbetween the Ignition Electrodes. The Electrode Adjustment Gauge islocated on the outside surface of the Diesel-Burner Head on the lefthandside.

Ignition Electrode Adjustment Procedure: An adjustment of the IgnitionElectrodes can be accomplished by performing the following procedures:

1. Slightly loosen the Retaining Clamp Bolt, reference Figure 16.

2. Place the Electrode Adjustment Gauge on the Nozzle Stand Hex(reference Figure 17) and insert the metal tips of the Ignition Elec-

IgnitionElectrodes

8.5 Ignition Electrodes

R

FlameSensor,continued

PhotoDisc

FlameSensor

GreenWire

BlueWire

Green Wire(to Diesel-Burner)

Violet Wire(to Diesel-Burner)

NOTE: This screw is used to fasten the Flame Sensor to the Photo Disc. Remove when replacing the Flame

Sensor.

Figure 15

Section 8: Diesel-Burner Service, Maintenance, and Repair Information

Page 52: Hydro-Hot Shop Manual Combined - myrvworks.com · 12 Volt-DC Battery Connections will seriously damage the Electronic Controller. Field Wiring Component Wiring Connections JP 3 JP

IgnitionElectrodes

ElectrodeAdjustment Gauge

(Properly Positioned)

RetainingClamp

Electrical Insulators

RetainingClamp Bolt

Nozzle Stand

FuelNozzle

Electrode AdjustmentGauge

IgnitionCables

Photo Disc

IgnitonElectrodes

(metal tips)

Page 49

Figure 16

Section 8: Diesel-Burner Service, Maintenance, and Repair Information

IgnitionElectrodes,continued

trodes into the appropriate notches of the Electrode AdjustmentGauge as illustrated in Figure 16.

3. Tighten the Retaining Clamp Bolt.

NOTE: Be sure not to overtighten the Retaining Clamp Bolt whenreadjusting the Ignition Electrodes. Overtightening the Retaining ClampBolt will bend the Retaining Clamp and prevent the Photo Disc fromfloating freely (i.e. loose fit). Not allowing the Photo Disc to float freelywill cause poor combustion and result in a smoky exhaust. A bentRetaining Clamp can be restraightened with a punch and hammer. Laythe clamp's beveled side down on a solid flat surface and align the thickend of the punch at dead center. Tap the punch lightly until the RetainingClamp returns to proper form (i.e. flat).

4. Remove the Electrode Adjustment Gauge and reattach to theDiesel-Burner Head.

Replacement Procedure:

1. Disconnect the Ignition Cables from the Ignition Electrodes andslightly loosen the Retaining Clamp Bolt just enough to allow theIgnition Electrodes to be removed, reference Figure 16.

2. Slide the new Ignition Electrodes up through the Retaining Clampand Photo Disc. Do not tighten the Retaining Clamp Bolt yet.

3. Perform Steps 2 thru 4, of this section's "Adjustment Procedure", tocomplete the Ignition Electrode installation. Once Steps 2 thru 4have been performed, connect the Ignition Cables to the IgnitionElectrodes, reference Figure 16.

Page 53: Hydro-Hot Shop Manual Combined - myrvworks.com · 12 Volt-DC Battery Connections will seriously damage the Electronic Controller. Field Wiring Component Wiring Connections JP 3 JP

Hydro-Hot Hydronic Heating System Shop Manual 07/03RPage 50

Section 8: Diesel-Burner Service, Maintenance, and Repair Information

Function: The Fuel Nozzle is simply a fuel atomizer. It reduces the dieselfuel into a fine spray which is mixed with incoming combustion air and isignited within the Combustion Chamber.

NOTE: In order to perform the following procedures it is necessary todetach and reattach the Diesel-Burner Head. Be sure to review Section8.2, Page 42 for detaching and reattaching instructions.

Component Test: Remove both Ignition Cables from the Ignition Electrodes(reference Figure 16), or connect a jumper wire (with alligator clips) acrossthe metal tips of the electrodes.

WARNING: Failure to connect a jumper wire across the Ignition Elec-trodes, or to remove the Ignition Cables from the Ignition Electrodes(reference Figure 16), will result in a HIGH VOLTAGE shock and/or a fire.If the Ignition Cables are removed, be sure to place a piece of electricaltape to the end of each cable.

Remove the B-Plug from the Diesel-Burner Head's Control Unit, referenceFigure 8. Turn the Diesel switch ON (reference Figure 4) and then plug theB-Plug back into the Control Unit to activate the Diesel-Burner. After approx.20 seconds, the Fuel Solenoid will "click" and a fine mist of fuel shouldappear from the Fuel Nozzle in a cone shaped spray pattern. Remove theB-Plug from the Control Unit. If the cone shaped spray pattern did notappear, the Fuel Nozzle must be replaced, reference the Fuel Nozzle's"Replacement Procedure" below. Reference Section 10 for spare partsinformation.

Cleaning Tips / Maintenance: The Fuel Nozzle is a precision calibratedpart and cannot be cleaned or serviced. A replacement of the Fuel Nozzleis recommended annually. Reference Section 8.1, Page 41 for maintenanceinformation.

Adjustment Procedure: N/A

Replacement Procedure:

1. Use a 3/4 in. wrench to hold the Fuel Nozzle Stand Hex while loosen-ing the Fuel Nozzle with a 5/8 in. wrench, reference Figure 17.

NOTE: Be sure to use care when handling the new Fuel Nozzle. Oilsand/or small dust or dirt particles from your hands may plug the nozzle'ssmall orifice. A partially plugged orifice will restrict fuel flow, which willaffect the combustion process of the Diesel-Burner (i.e. excessivesmoking).

2. When replacing the Fuel Nozzle, be sure to tighten the nozzle, loosenit a 1/4 turn, and then firmly retighten. This will establish a seated fitand avoid any leaks.

FuelNozzle

8.6 Fuel Nozzle

Page 54: Hydro-Hot Shop Manual Combined - myrvworks.com · 12 Volt-DC Battery Connections will seriously damage the Electronic Controller. Field Wiring Component Wiring Connections JP 3 JP

Hydro-Hot Hydronic Heating System Shop Manual 07/03R

NOTE: An adjustment of the Ignition Electrodes may be necessary afterreplacing the Fuel Nozzle. Reference Section 8.5, Page 48 for theIgnition Electrode "Adjustment Procedure".

3. After replacing the Fuel Nozzle, reattach the Diesel-Burner Head.

WARNING: Be sure to reattach the Diesel-Burner Head prior to switch-ing the heater ON. Failure to do so may result in ignition of the Diesel-Burner and serious bodily injury.

4. Turn ON the Diesel switch (reference Figure 4) for 5 seconds, thenturn it OFF. This will activate the Diesel-Burner's prime-cycle andflush the fuel system of any potential contaminants.

Fuel Nozzle

Fuel Nozzle

Fuel NozzleNozzle Stand Hex

Diesel-BurnerHead

5/8 in.Wrench

3/4 in.Wrench

Ignition Electrodes

Page 51

Figure 17

FuelNozzle,continued

Section 8: Diesel-Burner Service, Maintenance, and Repair Information

Page 55: Hydro-Hot Shop Manual Combined - myrvworks.com · 12 Volt-DC Battery Connections will seriously damage the Electronic Controller. Field Wiring Component Wiring Connections JP 3 JP

Hydro-Hot Hydronic Heating System Shop Manual 07/03RPage 52

FuelSolenoid

8.7 Fuel Solenoid

Function: The Fuel Solenoid allows the flow of diesel fuel to the Diesel-Burner's Fuel Nozzle.

NOTE: In order to perform the following procedures it is necessary todetach and reattach the Diesel-Burner Head. Be sure to review Section8.2, Page 42 for detaching and reattaching instructions.

Component Test: Locate and detach the C-Plug Harness' Violet (+) andBrown (-) wires from the Fuel Solenoid. Connect the (-) lead of a 12 voltDC power supply to the Fuel Solenoid's (-) Electrical Terminal, referenceFigure 18. Now, intermittently apply the (+) lead of the power supply to theFuel Solenoid's (+) Electrical Terminal and listen for the Fuel Solenoid toclick (i.e. open and close). If the Fuel Solenoid does not click, it must bereplaced, reference the Fuel Solenoid's "Replacement Procedure" below.Reference Section 10 for spare parts information.

Cleaning Tips / Maintenance: N/A

Adjustment Procedure: N/A

Replacement Procedure:

1. Disconnect the Ignition Cables from the Ignition Electrodes andloosen the Retaining Clamp Bolt, reference Figure 16.

2. Remove the Retaining Clip that secures the Photo Disc in place.Gently lift the Photo Disc (with Flame Sensor attached) so that itreleases from the Nozzle Stand and the Ignition Electrodes, refer-ence Figures 16 and 19.

3. Disconnect the C-Plug Harness' Violet (+) and Brown (-) wires fromthe Fuel Solenoid, reference Figure 18.

4. Remove the four Nozzle Stand Plate Screws that secure the NozzleStand Plate in place, reference Figure 19. Remove the NozzleStand Plate by pulling on the Nozzle Stand until the plate releasesfrom the cast-aluminum Blower Casing, reference Figures 13 and19.

5. Remove the Lock Nut and Flat Washer from the end of the FuelSolenoid Shaft and then remove the Fuel Solenoid. With theappropriate wrench, remove the Fuel Solenoid Shaft from theNozzle Stand. Discard the shaft and valve kit, as replacements areprovided with the new Fuel Solenoid Assembly.

6. Insert the contents of the new Fuel Solenoid Valve Kit into the newFuel Solenoid Shaft, as illustrated in Figure 18. Thread the new FuelSolenoid Shaft to the Fuel Nozzle Stand and tighten. Slide the newFuel Solenoid onto the Fuel Solenoid Shaft and secure in place withthe new Flat Washer and Lock Nut.

7. Fit the Nozzle Stand Plate inside the cast-aluminum Blower Casingand secure in place with the four Nozzle Stand Plate Screws.

Section 8: Diesel-Burner Service, Maintenance, and Repair Information

Page 56: Hydro-Hot Shop Manual Combined - myrvworks.com · 12 Volt-DC Battery Connections will seriously damage the Electronic Controller. Field Wiring Component Wiring Connections JP 3 JP

Hydro-Hot Hydronic Heating System Shop Manual 07/03R Page 53

Fuel Solenoid

Fuel SolenoidValve Kit

FuelSolenoid

Electrical Terminals

(+) (-)Fuel

Solenoid Shaft

Lock Nut

Photo Disc

Retaining Clamp

Ignition Cable

Violet wire

Brown wire

Retaining Clip

Fuel SolenoidAssembly

Section 8: Diesel-Burner Service, Maintenance, and Repair Information

FuelSolenoid,continued

8. Reinstall the Photo Disc and secure in place with the Retaining Clip.Connect the C-Plug Harness' Violet (+) and Brown (-) wires to theFuel Solenoid's (+) and (-) Electrical Terminals, reference Figure 18.

9. Perform the "Ignition Electrodes Adjustment Procedure" in Section8.5, Page 48 to complete the Fuel Solenoid installation.

NOTE: If a long after-smoking condition exists during the Diesel-Burner's purge-cycle (reference Page 12, Step 6), the Fuel SolenoidValve Kit may need to be replaced, reference Figure 18. Please contactour Technical Department at 1-800-685-4298 for assistance. ReferenceSection 10 for spare parts information.

Figure 18

Page 57: Hydro-Hot Shop Manual Combined - myrvworks.com · 12 Volt-DC Battery Connections will seriously damage the Electronic Controller. Field Wiring Component Wiring Connections JP 3 JP

Hydro-Hot Hydronic Heating System Shop Manual 07/03RPage 54

NOTE: In order to perform some of the following procedures it may benecessary to detach and reattach the Diesel-Burner Head. Be sure toreference Section 8.2, Page 42 for detaching and reattaching instruc-tions.

Component Test:

Clamp off and remove the Hydro-Hot's Fuel Return and Fuel Supply Lines,reference Figure 1. Attach a short piece of fuel line to both the Hydro-Hot'sFuel Return and Fuel Supply ports, reference Figure 1. Submerse theopposite end of the temporary fuel supply line in a container of diesel fuel.Place the opposite end of the temporary fuel return line in an emptycontainer. Turn the Diesel switch ON to activate the Diesel-Burner, refer-ence Figure 4. If fuel does not flow out of the return line into the emptycontainer, the Fuel Pump must be replaced, reference the Fuel Pump's"Replacement Procedure" on Page 58. Reference Section 10 for spareparts information.

NOTE: Prior to replacing the Fuel Pump, be sure to inspect the ScreenFilter in the supply inlet of the Fuel Pump, for dirt particles (referenceFigure 19). Clean and/or replace, if necessary. A plugged Screen Filterwill restrict fuel from entering the Fuel Pump. Reference the Hydro-Hot's"Parts Manual" for spare parts information.

Cleaning Tips / Maintenance:

1. Check all Fuel Connections for tightness (i.e. Banjo Bolts, HighPressure Fuel Pipe Connections, reference Figure 19.

2. Check the Screen Filter, located in the fuel supply inlet of the FuelPump, for dirt particles. Clean and/or replace, if necessary (refer-ence Figure 19).

Function: The Fuel Pump draws diesel fuel from the vehicle's fuel tankand creates a preset pressure of 145 psi (required for proper fuel atomi-zation). Reference the illustration below for a basic overview and under-standing of how the Fuel Pump functions.

Section 8: Diesel-Burner Service, Maintenance, and Repair Information

Fuel Pump 8.8 Fuel Pump

1. Fuel Nozzle2. Air Relief Bore3. Fuel Supply Line4. Fuel Return Line5. Fuel Pressure Regulator6. Fuel Solenoid

FUEL PUMPOVERVIEW

Page 58: Hydro-Hot Shop Manual Combined - myrvworks.com · 12 Volt-DC Battery Connections will seriously damage the Electronic Controller. Field Wiring Component Wiring Connections JP 3 JP

Hydro-Hot Hydronic Heating System Shop Manual 07/03R Page 55

SupplyBanjo Bolt

Fuel ReturnBanjo Pipe

Fuel SupplyBanjo Pipe

Fuel Supply Line

Top CoverPlate Screws

ScreenFilter

Pump MountingScrew

Fuel PressureRegulator

IgnitionElectrodes

Photo Disc

Retaining Clip

Flame Sensor

RetainingClamp

Nozzle StandPlate Screw (2)

Nozzle StandPlate Screw (1)

Fuel Pump

High PressureFuel Pipe Connections

ReturnBanjo Bolt

Nozzle StandPlate Screw (3)

Nozzle StandPlate Screw (4)

Nozzle StandPlate

Ignition Cable (1)

Ignition Cable (2)

Fuel ReturnLine

Section 8: Diesel-Burner Service, Maintenance, and Repair Information

Fuel Pump,continued

Figure 19

Page 59: Hydro-Hot Shop Manual Combined - myrvworks.com · 12 Volt-DC Battery Connections will seriously damage the Electronic Controller. Field Wiring Component Wiring Connections JP 3 JP

Hydro-Hot Hydronic Heating System Shop Manual 07/03R

Section 8: Diesel-Burner Service, Maintenance, and Repair Information

Page 56

Fuel Pressure Adjustment Check:

NOTES:A: A Fuel Pressure Gauge (reference Section 11 for special tools

information) is used to properly check the Fuel Pump's pressuresetting, reference Figure 20. The Fuel Pump is preset to 145 psi(the pressure required for proper fuel atomization at the FuelNozzle). Perform the following procedures to check for a properfuel pressure setting.

B: Be sure to use care when handling the Fuel Nozzle. Oils and/orsmall dust or dirt particles from your hands may plug the nozzle'ssmall orifice, reference Figure 9. A partially plugged orifice willrestrict fuel flow, which will affect the combustion process of theDiesel-Burner (i.e. excessive smoking from the exhaust pipe).

1. Remove the Fuel Nozzle (reference Figure 17) and replace it withthe Fuel Pressure Gauge, reference Figure 20.

WARNING: A spark will appear across the Ignition Electrodes (refer-ence Figure 16) for a brief moment after the Diesel-Burner has beenactivated. DO NOT attempt to make any fuel pressure adjustments untilthe spark has disappeared. Failure to do so may result in serious bodilyinjury (i.e. electrical shock).

2. Turn the Diesel switch ON, reference Figure 4. A pressure willregister on the Fuel Pressure Gauge once the Fuel Solenoid opens(after approx. 10-25 seconds).

3. If the Fuel Pressure Gauge registers a 145 psi pressure reading, nopressure adjustment is necessary. Turn the Diesel switch OFF andwait until the motor stops running. Remove the Fuel PressureGauge and reinstall the Fuel Nozzle (reference Section 8.6, Page 50for the Fuel Nozzle's "Replacement Procedure"). Reattach theDiesel-Burner Head.

NOTE: If the Fuel Pressure Gauge registers below or above 145 psi,perform the adjustment procedures listed below.

Fuel Pressure Adjustment Procedure:

1. Turn the Diesel switch ON and simply turn the Pressure RegulatorAdjustment Screw clockwise to increase fuel pressure or counterclockwise to decrease fuel pressure, reference Figure 21.

NOTE: If the fuel pressure will not maintain a 145 psi setting, the FuelPump must be replaced, reference the Fuel Pump's "ReplacementProcedure" on Page 58. Also, reference Section 10 for spare partsinformation.

2. Once the pressure adjustment has been made, turn the Dieselswitch OFF and wait until the motor stops running. Remove the FuelPressure Gauge and reinstall the Fuel Nozzle (reference Section8.6, Page 50 for the Fuel Nozzle's "Replacement Procedure").Reattach the Diesel-Burner Head.

Fuel Pump,continued

Page 60: Hydro-Hot Shop Manual Combined - myrvworks.com · 12 Volt-DC Battery Connections will seriously damage the Electronic Controller. Field Wiring Component Wiring Connections JP 3 JP

Hydro-Hot Hydronic Heating System Shop Manual 07/03R Page 57

6080 100 120

140

160

180200

40

200

psi

TFORCHSAMADE IN U.S.A

Fuel PressureGauge

PressureRegulator

(Adjustment)

Fuel Pumpincrease

decrease

Figure 20

Section 8: Diesel-Burner Service, Maintenance, and Repair Information

Fuel Pump,continued

Figure 21

Page 61: Hydro-Hot Shop Manual Combined - myrvworks.com · 12 Volt-DC Battery Connections will seriously damage the Electronic Controller. Field Wiring Component Wiring Connections JP 3 JP

Hydro-Hot Hydronic Heating System Shop Manual 07/03RPage 58

Section 8: Diesel-Burner Service, Maintenance, and Repair Information

Replacement Procedure:

1. Locate and disconnect the C-Plug Harness wires that connect to theFlame Sensor and the Fuel Solenoid, reference Figures 3, 15, and18. Also, disconnect the Ignition Cables from the Ignition Elec-trodes, reference Figures 16 and 19.

2. Remove the Retaining Clip that secures the Photo Disc in place,reference Figure 19. Gently lift the Photo Disc (with Flame Sensorattached) so that it releases from the Nozzle Stand and the IgnitionElectrodes, reference Figures 16 and 19.

3. Clamp off both the Fuel Supply and Return Lines from the Diesel-Burner Head, reference Figures 19 and 22. Loosen the Supply andReturn Banjo Bolts to remove the Fuel Supply and Return Pipes(with the fuel lines attached) from the Fuel Pump, reference Figures19 and 22. Also, disconnect the High Pressure Fuel Pipe from boththe Fuel Pump and the Nozzle Stand, reference Figures 19 and 22.Discard the High Pressure Fuel Pipe, Gasket Rings, Banjo Bolts,and Grommets, as replacements are provided in the new Fuel PumpKit (Part No. WPX-502-05A).

4. Remove the four Nozzle Stand Plate Screws that secure the NozzleStand Plate in place, reference Figure 19. Remove the NozzleStand Plate by pulling on the Nozzle Stand until the plate releasesfrom the cast-aluminum Blower Casing, reference Figures 13 and19.

5. Remove the two Pump Mounting Screws that secure the Fuel Pumpin place, reference item 70 of Figure 22. Turn the Nozzle StandPlate over and remove the Snap Ring from the Fuel Pump shaft,using snap ring pliers, reference item 89 of Figure 22. Remove thenylon Drive Gear and then the Fuel Pump, reference items 88 and72 of Figure 22.

6. Attach the new Fuel Pump to the Nozzle Stand Plate with the twoPump Mounting Screws. Turn the Nozzle Stand Plate over toinstall the nylon Drive Gear on the Fuel Pump's shaft and secure inplace with the Snap Ring. Dab the teeth of the nylon Drive Gearwith white lithium grease (Isoflex LDS-18 is recommended).

NOTES:A: Do not adjust the Fuel Pressure Regulator of the new Fuel Pump, as

it has been factory preset.

B: Inspect the nylon Drive Gear's cavity inside the cast aluminumBlower Casing for fuel stains. If fuel stains are present, a replace-ment of the Bearings and/or the entire Bower Casing may benecessary (leaking fuel could cause Bearing seizure, resulting inpotential damage to the internal bore / bearing cavity of the BlowerCasing). Reference Section 8.9, Page 60 for the Bearing "Replace-ment Procedure" and contact our Technical Department at 1-800-685-4298 for additional assistance.

7. Fit the Nozzle Stand Plate inside the cast-aluminum Blower Casing

Fuel Pump,continued

Page 62: Hydro-Hot Shop Manual Combined - myrvworks.com · 12 Volt-DC Battery Connections will seriously damage the Electronic Controller. Field Wiring Component Wiring Connections JP 3 JP

Hydro-Hot Hydronic Heating System Shop Manual 07/03R

Figure 22

Section 8: Diesel-Burner Service, Maintenance, and Repair Information

Fuel Pump,continued

Page 59

and secure in place with the four Nozzle Stand Plate Screws.Install the new Grommets on the Fuel Return and Supply BanjoPipes (with the fuel lines attached) and secure the pipes to the FuelPump with the new Banjo Bolts and Gasket Rings, reference Figure22.

NOTE: Reference Figure 22 for the correct order placement of the (4)Gasket Rings. Failure to use the new Gasket Rings, and/or the correctorder placement, could result in a fuel leak.

8. Reconnect the C-Plug Harness' Violet (+) and Brown (-) wires to theFuel Solenoid's (+) and (-) Electrical Terminals, reference Figure 18.Insert both Ignition Cables into the new rubber Grommet and slideinto the appropriate notch on the Blower Casing, reference Figure19. Reconnect the Ignition Cables to the Ignition Electrodes andremove the fuel line clamps from the Fuel Return and Supply Lines.

9. Reinstall the Photo Disc and secure it in place with the RetainingClip, reference Figure 19. Reconnect the Flame Sensor's Greenwire to the Green C-Plug Harness wire and the Blue wire to the C-Plug Harness' Violet wire, reference Figure 15.

NOTE: Check the Ignition Electrodes for proper adjustment, referenceSteps 2 thru 4, of the Adjustment Procedure in Section 8.5, Page 48 toensure proper Ignition Electrode adjustment.

Page 63: Hydro-Hot Shop Manual Combined - myrvworks.com · 12 Volt-DC Battery Connections will seriously damage the Electronic Controller. Field Wiring Component Wiring Connections JP 3 JP

Hydro-Hot Hydronic Heating System Shop Manual 07/03RPage 60

Section 8: Diesel-Burner Service, Maintenance, and Repair Information

Bearings 8.9 Bearings

Function: The Bearings support the Combustion Air Blower's shaft andallows the blower to turn smoothly.

NOTE: In order to perform some of the following procedures it is neces-sary to detach and reattach the Diesel-Burner Head. Be sure to reviewSection 8.2, Page 42 for detaching and reattaching instructions.

Function Test: Remove the Motor (reference Section 8.3, Page 45 for theMotor's "Replacement Procedure") and spin the Combustion Air Blower byhand (place one of the Clutch Halves to the end of the shaft to assist withthis spinning exercise). If the Combustion Air Blower rotates smoothlywithout any friction or noise, the Bearings are in proper working condition.However, if the Combustion Air Blower does not rotate smoothly and/orproduces noise, the Bearings are worn and must be replaced, referencethe Bearings "Replacement Procedure" below.

Component Test: N/A

Cleaning Tips / Maintenance: N/A

Adjustment Procedure: N/A

Replacement Procedure:

1. Clamp off and remove the Fuel Supply and Return Lines from theDiesel-Burner Head, reference Figures 19 and 22.

2. Locate and disconnect the C-Plug Harness wires that connect to theFlame Sensor and Fuel Solenoid, reference Figures 3, 15 and 18.Also, disconnect the Ignition Cables from the Ignition Electrodes,reference Figures 16 and 19.

3. Remove the four Nozzle Stand Plate Screws that secure the NozzleStand Plate in place, reference Figure 19. Remove the NozzleStand Plate by pulling on the Nozzle Stand until the plate releasesfrom the cast-aluminum Blower Casing, reference Figures 13 and19.

4. Remove the four Ignition Coil Screws that secure the Ignition Coilto the Protection Cap, reference Figure 13. Lift the Ignition Coil anddisconnect its Black (+) and Brown (-) wires from the C-Plug Har-ness wires, prior to removing (reference Figures 3 and 24). Re-move the Protection Cap from the Diesel-Burner so that the Motorand Clutch Halves are exposed, reference Figures 12 and 14.

5. Remove the three Hex Head Screws that secure the Motor andMotor Flange to the Blower Housing, reference Figure 13. Removethe Motor and flange assembly along with the Clutch Halves,reference Figures 13 and 14. Disconnect the Motor's Black (+) andBrown (-) wires from the C-Plug Harness' wires, reference Figure13.

Page 64: Hydro-Hot Shop Manual Combined - myrvworks.com · 12 Volt-DC Battery Connections will seriously damage the Electronic Controller. Field Wiring Component Wiring Connections JP 3 JP

Hydro-Hot Hydronic Heating System Shop Manual 07/03R Page 61

NOTE: Inspect the Clutch Halves' for cracks and also ensure that theflat portion in each shaft hole is free of wear and tear. Too much play onthe shaft produces a loud clacking noise. If any cracks or wear aredetected, the Clutch Half must be replaced. Reference the Hydro-Hot's"Parts Manual" for spare parts information.

6. Remove the four Blower Housing Screws that secure the BlowerHousing to the Blower Casing, reference Figure 23. Remove theBlower Housing so that the Combustion Air Blower is exposed,reference Figure 23.

NOTE: Be sure to observe the placement of the three Washers of theBearing Kit illustrated in Figure 23. To ensure proper tension, the sameorder and direction of the dished surfaces of the Washers must befollowed when reassembling.

7. Hold Side-B of the Blower Casing and loosen the Retaining Nutlocated in Side-A of the Blower Casing. Remove the Retaining Nut,steel Drive Gear, and thick Flat Washer from the Combustion AirBlower's shaft. Lightly tap the threaded end of the shaft so that theCombustion Air Blower can be easily removed from the BlowerCasing.

8. With a pair of snap-ring pliers, remove the Snap Rings from bothSide-A and Side-B of the Blower Casing, reference Figure 23. Pushall the contents of the Bearing Kit out of the Blower Casing's bore /bearing cavity. Discard the Retaining Nut, steel Drive Gear, SnapRings, Bearings, Spacer Tube, and Washers, as replacements areprovided in the new Bearing Kit.

NOTE: Be sure to inspect the Blower Casing's bore / bearing cavity forsigns of damage due to potentially seized Bearings. If damage ispresent, the Blower Casing must be replaced. Reference the Hydro-Hot's "Parts Manual" for spare parts information.

9. Install a new Snap Ring into Side-A of the Blower Casing, refer-ence Figure 23. Once the Snap Ring is in place, insert the remain-ing contents of the new Bearing Kit into Side-B of the BlowerCasing, starting with the Wave Washer, as illustrated in Figure 23.Secure the Bearing Kit assembly in place with the remaining SnapRing (Side-B).

NOTES:A: Reference Figure 23 for exact placement of the three Washers that

slide over the threaded end of the Combustion Air Blower's shaftprior to installation. Failure to follow the correct order and directionof the dished surfaces on the Washers will result in a restrictedrotation of the Combustion Air Blower.

B: Inspect the Combustion Air Blower for warpage and/or damage. Ifwarpage or damage is visible, the Combustion Air Blower must bereplaced. Reference the Hydro-Hot's "Parts Manual" for spare partsinformation.

10. Slide the Combustion Air Blower's shaft (with the three washers) up

Section 8: Diesel-Burner Service, Maintenance, and Repair Information

Bearings,continued

Page 65: Hydro-Hot Shop Manual Combined - myrvworks.com · 12 Volt-DC Battery Connections will seriously damage the Electronic Controller. Field Wiring Component Wiring Connections JP 3 JP

Hydro-Hot Hydronic Heating System Shop Manual 07/03R

Section 8: Diesel-Burner Service, Maintenance, and Repair Information

Page 62

through the Bearing Kit assembly until the threaded portion appearson Side-A of the Blower Casing, reference Figure 23. Place the newthick flat Washer and steel Drive Gear on the threaded end of theCombustion Air Blower's shaft. Thread the new Retaining Nut on theCombustion Air Blower's shaft until it is finger tight (DO NOTTIGHTEN).

11. Place a feeler gauge between the Combustion Air Blower and theflat surface of the Blower Casing. Slowly tighten (or loosen) theRetaining Nut, holding the Combustion Air Blower, until a .003 - .005gap is achieved.

12. Spin the Combustion Air Blower to ensure a friction free rotation.

NOTE: If the Combustion Air Blower is rubbing, loosen the RetainingNut slightly and lightly tap on the Combustion Air Blower's shaft (oppo-site side {i.e. Side-B}), then readjust the gap (repeat Steps 11 and 12).

13. Reattach the Blower Housing to the Blower Casing using the fourBlower Housing Screws. Reinstall a Clutch Half on both the Motor'sshaft and the Combustion Air Blower's shaft. Attach the Motor andflange assembly, with the recessed edge of the Motor Flange in-linewith the wiring access slot of the Blower Casing, to the BlowerHousing with the three Hex Head Screws, reference Figure 14.Reconnect the Black (+) and Brown (-) wires of the Motor to the C-Plug Harness' Black (+) and Brown (-) wires, reference Figure 13.Feed the C-Plug Harness' Yellow and Brown wires back through thewiring access hole in the Protection Cap, reference Figure 14.

15. Reinstall the Protection Cap. Reconnect the Black (+) and Brown (-)wires of the Ignition Coil to the C-Plug Harness' Yellow (+) andBrown (-) wires, reference Figure 24. Reinstall the Ignition Coil andsecure to the Protection Cap with the four Ignition Coil Screws,reference Figure 13. Reconnect the Ignition Cables to the IgnitionElectrodes, reference Figure 16.

16. Fit the Nozzle Stand Plate inside the cast-aluminum Blower Casingand secure in place with the four Nozzle Stand Plate Screws.Reattach the Fuel Supply and Return Lines to the Diesel-BurnerHead.

17. Reconnect the Blue (+) and Brown (-) wires to the Fuel Solenoid's(+) and (-) Electrical Terminals, reference Figure 18. Also, recon-nect the Flame Sensor's Green wire to the Green C-Plug Harnesswire and the Blue wire to the C-Plug Harness' Violet wire, referenceFigure 15.

Bearings,continued

Page 66: Hydro-Hot Shop Manual Combined - myrvworks.com · 12 Volt-DC Battery Connections will seriously damage the Electronic Controller. Field Wiring Component Wiring Connections JP 3 JP

Hydro-Hot Hydronic Heating System Shop Manual 07/03R

Blower HousingScrews

Blower Housing

Combustion AirBlower w/shaft

Blower CasingO-Ring

Blower CasingRubber

Grommets

DishedSurfaceWasher

DishedSurfaceWasher

FlatWasher

SnapRing Bearing

SpacerTube

Bearing

WaveWasher Snap

Ring FlatWasher(Thick)

DriveGear

(Steel)

RetainingNut

Bearing Kit

Side-B Side-A

Figure 23

Bearings,continued

Section 8: Diesel-Burner Service, Maintenance, and Repair Information

Page 63

Page 67: Hydro-Hot Shop Manual Combined - myrvworks.com · 12 Volt-DC Battery Connections will seriously damage the Electronic Controller. Field Wiring Component Wiring Connections JP 3 JP

Hydro-Hot Hydronic Heating System Shop Manual 07/03RPage 64

Section 8: Diesel-Burner Service, Maintenance, and Repair Information

Ignition Coil 8.10 Ignition Coil

Function: The Ignition Coil produces a high voltage ignition spark(approx. 8000 volts), which is released across the metal tips of theIgnition Electrodes during the initial Diesel-Burner start-up.

WARNING: Use extreme care when testing the Ignition Coil, as a HighVoltage Shock may result.

NOTE: In order to perform some of the following procedures it is neces-sary to detach and reattach the Diesel-Burner Head. Be sure to reviewSection 8.2, Page 42 for detaching and reattaching instructions.

Component Test: Remove the four Ignition Coil Screws that secure theIgnition Coil in place, reference Figure 13. Disconnect the Ignition Coil'sBlack (+) and Brown (-) wires from the C-Plug Harness' Yellow (+) andBrown (-) wires. Connect the Ignition Coil wires directly to a 12 volt DCpower supply (i.e. Black (+) wire to (+) lead and Brown (-) wire to (-) lead).Turn the power supply ON and watch for a spark to appear across themetal tips of the Ignition Electrodes, reference Figure 16. If a spark doesnot appear, the Ignition Coil must be replaced, reference the Ignition Coil's"Replacement Procedure" below. Reference Section 10 for spare partsinformation.

Cleaning Tips / Maintenance: N/A

Adjustment Procedure: N/A

Replacement Procedure:

1. Disconnect the Ignition Cables from the Ignition Electrodes, refer-ence Figures 16 and 19. Remove the four Ignition Coil Screws thatsecure the Ignition Coil to the Protection Cap, reference Figure 13.Lift the Ignition Coil and disconnect its wires from the C-PlugHarness wires, prior to removing (reference Figures 3 and 24).

2. Connect the new Ignition Coil's Black (+) and Brown (-) wires to theC-Plug Harness' Yellow (+) and Brown (-) wires, reference Figure24. Attach the Ignition Coil to the Protection Cap with the fourIgnition Coil Screws, then reconnect the Ignition Cables to theIgnition Electrodes.

Figure 24

IgnitionCoil

BlackWire (+)

BrownWire (-)

IgnitionCable

Yellow Wire (+)(to Diesel-Burner)

Brown Wire (-)(to Diesel-Burner)

Page 68: Hydro-Hot Shop Manual Combined - myrvworks.com · 12 Volt-DC Battery Connections will seriously damage the Electronic Controller. Field Wiring Component Wiring Connections JP 3 JP

Hydro-Hot Hydronic Heating System Shop Manual 07/03R Page 65

Section 8: Diesel-Burner Service, Maintenance, and Repair Information

Control Unit 8.11 Control Unit

Function: The Control Unit operates all the components of the Diesel-Burner Head and safely shuts the heater OFF in the event of an overheat,flameout, and low voltage condition. It also receives Diesel-Burneroperation status signals from the Flame Sensor, VDC Control Thermostat,and VDC High-Limit Thermostat.

Component Test: The following conditions must exist prior to performingthe Control Unit circuit tests on the following page. If one of the conditionsbelow does not exist, please contact our Technical Support Department at1-800-685-4298 for additional assistance.

Condition #1A battery voltage level of between 11.5 to 14.0 volts DC must bepresent at the Control Unit during all testing, reference Figure 25. Itmay be necessary to perform a voltage check to ensure that thiscondition exists. To perform the voltage check, locate the ControlUnit's B-Plug, and insert the probes of a DC voltmeter into the B-4(+) and B-2 (-) locations, reference Figure 26.

Condition #2A voltage level of between 11.5 to 14.0 volts must be present at theDiesel ON/OFF switch circuit of the Control Unit during all testing. Itmay be necessary to perform a voltage check to ensure that thiscondition exists. To perform the voltage check, locate the ControlUnit's B-Plug, and insert the probes of a DC voltmeter into the B-1(+) and B-2 (-) locations, reference Figure 8. Turn the Diesel switchON and observe the voltage level, reference Figure 4.

Diesel-BurnerControl Unit

Diesel-BurnerHead Figure 25

Page 69: Hydro-Hot Shop Manual Combined - myrvworks.com · 12 Volt-DC Battery Connections will seriously damage the Electronic Controller. Field Wiring Component Wiring Connections JP 3 JP

Hydro-Hot Hydronic Heating System Shop Manual 07/03R

Section 8: Diesel-Burner Service, Maintenance, and Repair Information

(+)COM (-)

V 5.21

B-2 ( - ) Battery Circuit (Brown Wire)to JP-4 (Pin 4)

B-4 ( + ) Battery Circuit (Red Wire)to JP-4 (Pin 3)

B-Plug B-1 B-2 B-3B-4 B-6

Control Unit,continued

Figure 26

Page 66

Page 70: Hydro-Hot Shop Manual Combined - myrvworks.com · 12 Volt-DC Battery Connections will seriously damage the Electronic Controller. Field Wiring Component Wiring Connections JP 3 JP

Hydro-Hot Hydronic Heating System Shop Manual 07/03R Page 67

Section 8: Diesel-Burner Service, Maintenance, and Repair Information

Control Unit,continued

NOTE: If after performing the following circuit tests, the Control Unit isdetermined to be defective, and must be replaced, reference the ControlUnit's "Replacement Procedure" on the following page. ReferenceSection 10 for spare parts information.

Ground circuit testLocate the Control Unit's B-Plug and C-Plug, reference Figure 8. Insert theprobes of a DC voltmeter into the B-4 (+) and C-5 (-) locations and turn theDiesel switch ON, reference Figures 4 and 8. If a voltage reading does notregister on the voltmeter, the Control Unit must be replaced. If voltage ispresent, proceed to the next circuit test.

VDC / VAC Control Thermostat circuit testLocate the Control Unit's B-Plug and C-Plug, reference Figure 8. Insert theprobes of a DC voltmeter into the C-1 (+) and B-2 (-) locations and turn theDiesel switch ON, reference Figures 4 and 8. If a voltage reading does notregister on the voltmeter, the Control Unit must be replaced. If voltage ispresent, proceed to the next circuit test.

VDC High-Limit Thermostat circuit testLocate the Control Unit's B-Plug and C-Plug, reference Figure 8. Insert theprobes of a DC voltmeter into the C-4 (+) and B-2 (-) locations and turn theDiesel switch ON, reference Figures 4 and 8. If a voltage reading does notregister on the voltmeter, the Control Unit must be replaced. If voltage ispresent, proceed to the next circuit test.

Motor circuit testLocate the Control Unit's C-Plug, reference Figure 8. Use a jumper wire tomake a connection from the C-1 location to the C-7 location, referenceFigure 8. Turn the Diesel switch ON and insert the probes of a DC voltme-ter into the C-2 (+) and C-5 (-) locations, reference Figures 4 and 8. If novoltage reading registers on the voltmeter, the Control Unit must be re-placed. If voltage is present, proceed to the next circuit test.

CAUTION: Be sure to remove the jumper wire that was used to makethe connection from the C-1 location to the C-7 location. A failure to doso will result in an overheating condition during normal operation.

Ignition Coil circuit testTurn the Diesel switch OFF and locate the Control Unit's C-Plug, referenceFigures 4 and 8. Use a jumper wire to make a connection from the C-1location to the C-7 location, reference Figure 8. Also, locate the VDC High-Limit Thermostat and disconnect it's 2-way male plug from the (whiteplastic) 6-way female connector, reference Figure 1. Insert the probes of aDC voltmeter into the C-8 (+) and C-5 (-) locations and turn the Dieselswitch ON, reference Figures 4 and 8. If a voltage reading does notregister on the voltmeter, 18-25 seconds after the initial start-up, theControl Unit must be replaced.

Page 71: Hydro-Hot Shop Manual Combined - myrvworks.com · 12 Volt-DC Battery Connections will seriously damage the Electronic Controller. Field Wiring Component Wiring Connections JP 3 JP

Hydro-Hot Hydronic Heating System Shop Manual 07/03R

Section 8: Diesel-Burner Service, Maintenance, and Repair Information

Page 68

Control Unit,continued

NOTE: Be sure to reconnect the VDC High Limit Thermostat's 2-waymale plug to the 6-way female plug. The Diesel-Burner will not igniteduring normal operation if the VDC High-Limit Thermostat is left discon-nected.

CAUTION: Be sure to remove the jumper wire that was used to makethe connection from the C-1 location to the C-7 location. A failure to doso will result in an overheating condition during normal operation.

Cleaning Tips / Maintenance: N/A

Adjustment Procedure: N/A

Replacement Procedure:

1. Remove both the B-Plug and C-Plug from the Control Unit, refer-ence Figure 8. Gently pry away each side of the Control UnitBracket from the Control Unit's locking posts with a flat-head screwdriver. Once the locking posts have been released, pull on theControl Unit to remove it from the Diesel-Burner Head.

2. Slide the new Control Unit into the Control Unit Bracket, referenceFigure 27. Push down on the Control Unit until the locking postssnap into the bracket slots. Reinstall both the B-Plug and C-Plug.

NOTE: Be sure to install the Control Unit with it's C-Plug and B-Plugports facing downward. Failure to do so, will result in moisture collectingin the ports and potential damage to the Control Unit's internal circuitry,reference Figure 27.

Page 72: Hydro-Hot Shop Manual Combined - myrvworks.com · 12 Volt-DC Battery Connections will seriously damage the Electronic Controller. Field Wiring Component Wiring Connections JP 3 JP

Hydro-Hot Hydronic Heating System Shop Manual 07/03R Page 69

7.11 Control Unit

Figure 27

Section 8: Diesel-Burner Service, Maintenance, and Repair Information

Control Unit,continued

Control Unit

Control UnitBracket

Bracket Slots

Locking Posts

Page 73: Hydro-Hot Shop Manual Combined - myrvworks.com · 12 Volt-DC Battery Connections will seriously damage the Electronic Controller. Field Wiring Component Wiring Connections JP 3 JP

Hydro-Hot Hydronic Heating System Shop Manual 07/03RPage 70

Section 9: Warranty Information

WARRANTY INFORMATION

Vehicle Systems Inc. warrants the HYDRO-HOT Heater to be free from defects in material andworkmanship under normal use and service for a period of two (2) years on both parts and laborcommencing upon the original date of registration of the vehicle. Replacement parts are war-ranted for the remainder of the Heater's standard warranty period or for six months (180 days),whichever is greater.

This warranty is conditional upon proper use of the Heater by the end-user. This war-ranty does not apply to damage or failure of the HYDRO-HOT Heater, or the vehicle intowhich it was installed, due to improper installation, assembly, maintenance, abuse,neglect, accident, or the use of parts not supplied by Vehicle Systems Inc. Vehicle Sys-tems is not responsible for incidental or consequential damages.

The intent of this warranty is to protect the end-user of the heating system from such defects,which would occur in the manufacture of the product. The warranty is not intended to protectthe end-user from problems, which are outside the ability of Vehicle Systems’ control.

To obtain warranty repair authorization or for additional product information, please contact ourTechnical Department at 1-800-685-4298 (8 AM to 5 PM Mountain Standard Time).

- FOR ALL HYDRO-HOT MODELS -

Page 74: Hydro-Hot Shop Manual Combined - myrvworks.com · 12 Volt-DC Battery Connections will seriously damage the Electronic Controller. Field Wiring Component Wiring Connections JP 3 JP

Hydro-Hot Hydronic Heating System Shop Manual 07/03R Page 71

Section 10: Spare Parts List

2 WPX-287-962 Control Unit, 12 VDC, DBW 2010-300, AH/HH/WH5 WPX-101-838 Coil, Ignition, 12 VDC, DBW 2010-300, AH/HH/WH27 WPX-425-060 Motor, Combustion Air/Fuel Pump, 12 VDC, DBW-2010, AH/HH/WH50 WPX-322-083 Assembly, Fuel Solenoid, 12 VDC, DBW 2010-300, AH/HH/WH51 WPX-386-650 Valve, Kit, Fuel Solenoid, DBW 2010-300, AH/HH/WH56 WPX-274-313 Electrode, Ignition, DBW-2010, AH/HH/WH59 WPX-638-78A Sensor, Flame, DBW 2010-300, AH/HH/WH61 WPX-887-71A Photo Disc, DBW-2010, AH/HH/WH62 WPX-886-41A Nozzle, Fuel, 0.35 GPH, DBW-2010, AH/HH/WH72 WPX-502-05A Pump, Fuel, 10 Bar, DBW 2010-300, AH/HH/WH302 FLX-120-VS1 Filter, Fuel, System, 10 Micron, AH/HH303 FLX-R12-TRA Filter, Fuel, Spin-On Element, 10 Micron, AH/HH305 WPE-905-83H Burner-Head, Diesel, Modified, VSI DBW-2010, 12 VDC, HH313 WPX-265-53A Combustion Chamber, DBW-2010, AH/HH/WH409 ELE-ASY-001 Thermostat Assembly, VAC High-Limit, 220�F, HH410 ELX-01G-ML7 Switch, Float, HH411 ELE-C14-001 Thermostat, VDC / VAC Control, 200�F, HH412 ELE-HLT-222 Thermostat, VAC High-Limit, 220�F, HH

410

412

409

411

305

B CA

Control Unit

12

1 2 364 5 5

2 486 7

1

303 302313

56

59

61

62

72 2

275

50

51

58M

R554

202

2L 6

- 98

022L

6- 9

858

MR5

542

SM

EG

Page 75: Hydro-Hot Shop Manual Combined - myrvworks.com · 12 Volt-DC Battery Connections will seriously damage the Electronic Controller. Field Wiring Component Wiring Connections JP 3 JP

Hydro-Hot Hydronic Heating System Shop Manual 07/03RPage 72

102 WPX-310-646 Gauge, Adjustment, Electrode, DBW 2010-300, AH/HH/WH138 WPX-440-280 Control Box, Tester, DBW 2010-300, AH/HH/WH139 WPE-600-190 Gauge Kit, Fuel Pressure, DBW 2010-300, AH/HH/WH140 **************** Gas Analyzer, CO2, AH/HH/WH

Order item #140 from a Grainger Industrial Supply Store near youor visit the Grainger website at www.grainger.com.(Grainger Part# 6T153)

6080 100 120

140

160

180200

40

200

psi

ASHC TFORMADE IN U.S.A

Section 11: Special Tools

Page 76: Hydro-Hot Shop Manual Combined - myrvworks.com · 12 Volt-DC Battery Connections will seriously damage the Electronic Controller. Field Wiring Component Wiring Connections JP 3 JP

15549 East Highway 52 ••••• Fort Lupton, Colorado 80621 ••••• 1-800-685-4298 ••••• Fax: 303-857-9000© © © © © Copyright 2002 Vehicle Systems, Inc. All rights reserved

www.vehiclesys.com

Motor Coach Heating Specialists Manufacturers and Distributors

LTE-VHS-220

Page 77: Hydro-Hot Shop Manual Combined - myrvworks.com · 12 Volt-DC Battery Connections will seriously damage the Electronic Controller. Field Wiring Component Wiring Connections JP 3 JP

This manual has been provided courtesy of My RV Works, Inc.

www.myrvworks.com

You can find more RV service manuals here: www.myrvworks.com/manuals

Over the years of running a mobile RV repair service, having a dedicated place to access service manuals for all the different appliances and components found on RVs was something that I always had a desire to create.

I hope this resource makes your RV repairs easier, as it has mine, but please be careful and follow proper safety practices when attempting to repair your own RV.

If in doubt, please consult with a professional RV technician!

All service manuals provided on www.myrvworks.com are believed to be

released for distribution and/or in the public domain.

DARREN KOEPP - OWNER, MY RV WORKS, INC.