Purpose made 'Rafter Tray' to ensure cross ventilation Eaves ventilation: 10mm continuous gap High level air brick to - ventilate new cavity Minimum 50mm cavity --- Low level air brick to -M ventilate new cavity Flo,hlog to b, - in satisfactory I r : High level vent tile to give equivalent 5mm gap - spacings fixed, and installed condition £ I I I 1 1 I to manufacturers specification Tyvec (or equivalent) breathable membrane 75 x 50mm C16 timber studwork Minimum 75mm Kingspan (or equivalent) 500 gauge Visqueen DPM (or equivalent) 12.5mm plasterboard and skim 100mm mineral wool insulation laid between joists 170mm mineral wool insulation laid at right angles above joists Minimum 22mm T&G floor boards - moisture resistant grade to utility, bathroom, kitchen etc. 1200 gauge Visqueen DPM (or equivalent) on existing concrete garage floor (if suitable) 100mm Kingspan (or equivalent) 50 x 100mm C16 treated timber floor External Ground Level- �1�ii��4�L J , - - i I I l_1 I - - Visqueen DPM lapped and taped up and around floor joists held in place by studding sole plate Detail: New floor meets new stud wall sole plate pro Jee Building Control �' BC garage conversion detail JB Jan 09 wg no: 1:20 1: 10 1 of 3

I JB - Wigan · 2019. 12. 18. · JB Feb 09 wg no: 1 :50 1 :20 2 of 3 Building Control ' LABC . Building Control ' LABC . Title: GarageConversionDetails1103kb.pdf Author: Mr System

  • Upload
    others

  • View
    6

  • Download
    0

Embed Size (px)

Citation preview

  • Purpose made 'Rafter Tray' to ensure cross ventilation

    Eaves ventilation: 10mm continuous gap

    High level air brick to ---1.i ventilate new cavity

    Minimum 50mm cavity ---

    Low level air brick to ---M ventilate new cavity

    Flo,hlog to b, � -in satisfactory I r : High level vent tile to give equivalent 5mm gap - spacings fixed, and installed

    condition "'-.

    £ I I I

    � 1

    1 I to manufacturers specification

    Tyvec (or equivalent) breathable membrane

    75 x 50mm C16 timber studwork

    Minimum 75mm Kingspan (or equivalent)

    500 gauge Visqueen DPM (or equivalent)

    12.5mm plasterboard and skim

    100mm mineral wool insulation laid between joists 170mm mineral wool insulation laid at right angles above joists

    Minimum 22mm T&G floor boards - moisture resistant grade to utility, bathroom, kitchen etc.

    1200 gauge Visqueen DPM (or equivalent) on existing concrete garage floor (if suitable) 100mm Kingspan

    (or equivalent) 50 x 100mm C16 treated timber floor

    External Ground Level-7"""7"""7"""7""""";f=,-:M;1,a1;1���1.i.i.�.Joiii��i....ii.i,;.;��..i,,j,,�,W;,�.;.;.JlL�4"�4Wl:lL;���..i..�L�� ......... .WWJJ

    , - - i

    I

    I l_1 _l_

    I

    L_ - - _J

    Visqueen DPM lapped and taped up and around floor joists held in place by studding sole plate

    Detail:

    New floor meets new stud

    wall sole plate

    pro Jee

    Building

    Control �' LABC

    garage conversion detail

    JB Jan 09wg no:

    1 :20 1: 10 1 of 3

  • " " " " " " " " " " " " " " " " " " " " " " " " " " " " " " " " " " " " " " " "

    11 I II

    - - - - - -, ,.. - - - - - ,.. - - - - - - - - - - , ,.. - - - - - ,.. - - - - -- - - - - -,, ,- - - - - - I I - - - - - I

    11 II

    11 II

    11 II

    11 II

    11 II

    11 II

    "

    " - - - -, I

    "

    " ----------,,-

    Cavity construction: 102.5mm facing brickwork

    (___

    -'-

    C-

    ---

    -'

    C-

    ---

    -'-

    I-

    -�

    -'-

    C-

    ---

    --

    I-

    -�

    I-

    --

    -

    Walls properly bonded (crocodile or similar wall ties)

    85mm fully filled cavity with Dritherm (or equivalent) 100mm Thermalite (or equivalent) internal blockwork Stainless steel wall ties at 900mm horizontal and 450mm vertical centres, maximum 300mm at reveals

    C----

    I-

    -

    C----

    -

    I-

    -

    Detail: Detail:

    -

    -

    -

    -

    -

    -

    -

    -

    -

    Ground Floor Plan First Floor Plan

    NB Slab thickness to be confirmed on site and deemed satisfactory to build off by LABC Officer

    NB The installation of insulation and ventilation to existing flat roofs is difficult, compliance with the regulations may best be achieved by constructing a warm roof. It is accepted that this could cause flashing problems but is probably the only realistic way of achieving compliance. On the plus side, properly constructed warm roofs are far more durable than cold roofs.

    ,(

    ,,,..__

    J v-'-........

    ----1 /,,-f---._

    SD

    ?

    ��'-

    500 gauge Visqueen DPM (or equivalent) trapped between exiting pier and and insulation board

    Minimum 25mm Kingspan (or equivalent) to prevent cold bridging on piers

    12.5mm plasterboard to run flush

    Detail:

    Existing garage pier

    .[) / j --'

    Synthaprufe (or equivalent) tanking system with 1200 gauge Visqueen DPM (or equivalent) laid over the top extending minimum half way into new cavity wall and

    De ta i l : returned to stud cavity

    New cavity construction in

    existing garage door opening

    NB If no direct external access in available off new extension and where not already present. works wl'll require mains wired smoke detection in all circulation areas, interlinked with battery back-up, manufactured installed and commissioned in accordance with Approved Document Band BS 5446: pt 1: 2000

    proJec

    garage conversion detail

    JB Feb 09 wg no:

    1 :50 1 :20 2 of 3