ICRU Report 95: Operational quantities for External

Radiation Exposure

What changes for Radiation Protection ?

Thomas Otto, ICRU and CERN

IAEA ORPAS Meeting, 17. 9. 2021

Page 2: ICRU Report 95 - nucleus-new.iaea.org

ICRU Report 95 (2020)Operational Quantities for External Radiation Exposure

• Previous quantities

(ICRU 39 and 51)

• Operational Quantities

for external exposure

• Conversion Coefficients

• Practical Consequences

• Appendices

• Values of Conversion

coefficients

• Computer Codes

Th. Otto - ICRU Report 95 - IAEA ORPAS - 17. 9. 2021 2

Page 3: ICRU Report 95 - nucleus-new.iaea.org

• Short excursion to quantity definition

• What changes ?

• Effect on dose values in radiation fields

• Effect on instrument calibration

• Summary

Th. Otto - ICRU Report 95 - IAEA ORPAS - 17. 9. 2021 3

Page 4: ICRU Report 95 - nucleus-new.iaea.org

Protection vs. Operational Quantities

• ICRP defines protection quantity Effective Dose based on absorbed dose to express risk, constraints and limits

• Protection quantity defined over the volume of a body,not measurable

• ICRU proposes operational quantities, defined in a point and measurable

X

Th. Otto - ICRU Report 95 - IAEA ORPAS - 17. 9. 2021 4

Page 5: ICRU Report 95 - nucleus-new.iaea.org

Relation of QuantitiesPhysical Quantities

F, Ka, D

Protection Quantity Operational Quantities

MeasurementInstrument response R (E,W)

Calculation

With

Phantoms

Calculation

With

Phantoms

Numerical value for

specified radiation field

Numerical value for

specified radiation field ?

Th. Otto - ICRU Report 95 - IAEA ORPAS - 17. 9. 2021 5

Page 6: ICRU Report 95 - nucleus-new.iaea.org

Today

Physical Quantities

F, Ka, D

Protection QuantityEffective dose E

Operational QuantitiesAmbient dose equivalent H*(10)Personal dose equivalent Hp(10)

MeasurementInstrument response R (E,W)

For photons in kerma approximation

𝐸 = න𝑑𝐸p 𝛷𝐸pℎ𝐸(𝐸p, inc∗)

* incident directions: AP, PA, LLAT, RLAT, ROT, ISO

Calculation:

Anthropomorphic

Phantoms

Calculation:

Geometric

Phantoms

𝐻𝑝 𝑑, Ω = ඵ𝑑𝐸p𝑑𝜴 𝛷𝐸pℎ𝑝 𝑑,𝐸p, 𝜴

𝐻∗ 𝑑, Ω = ඵ𝑑𝐸p𝑑𝜴 𝛷𝐸pℎ∗ 𝑑,𝐸p,𝜴

Th. Otto - ICRU Report 95 - IAEA ORPAS - 17. 9. 2021 6

Page 7: ICRU Report 95 - nucleus-new.iaea.org

What changes ?

• Operational quantities from present to future:

• Change to anthropomorphic phantoms

• Better approximation of E by definition

• Also:

• Definition of quantities to limit tissue effects (local dose to skin and to eye lens) as absorbed dose

• More radiation types, e.g. positrons, protons, pions…

• Much wider energy range

Th. Otto - ICRU Report 95 - IAEA ORPAS - 17. 9. 2021 7

Page 8: ICRU Report 95 - nucleus-new.iaea.org

ICRU Report 95

Physical Quantities

F, Ka, D

Protection QuantityEffective dose E

Operational QuantitiesAmbient dose H*Personal dose Hp

MeasurementInstrument response R (E,W)

𝐸 = න𝑑𝐸p 𝛷𝐸pℎ𝐸(𝐸p, inc∗)

* incident directions: AP, PA, LLAT, RLAT, ROT, ISO

Calculation:

Anthropomorphic

Phantoms

𝐻∗ = න𝑑𝐸p 𝛷𝐸p ⋅ ℎ𝐸max(𝐸𝑝)

𝐻p = 𝑑𝛺 𝑑𝐸p𝛷𝐸p ⋅ ℎp (𝐸p,𝒂)

Calculation:

Anthropomorphic

Phantoms

Th. Otto - ICRU Report 95 - IAEA ORPAS - 17. 9. 2021 8

Page 9: ICRU Report 95 - nucleus-new.iaea.org

What changes – Photons

Th. Otto - ICRU Report 95 - IAEA ORPAS - 17. 9. 2021

Effective dose E vs.

Personal Dose equivalent Hp(10)

Effective dose E vs.

Personal Dose Hp

9

Page 10: ICRU Report 95 - nucleus-new.iaea.org

What changes – Neutrons

Th. Otto - ICRU Report 95 - IAEA ORPAS - 17. 9. 2021

0.1

1

10

100

1000

1.00E-09 1.00E-07 1.00E-05 1.00E-03 1.00E-01 1.00E+01 1.00E+03

hE(

W),

h*(

10

)

(pSv

cm2 )

Neutron Energy (MeV)

AP

PA

LLAT

RLAT

ISO

ROT

H*(10)

0.1

1

10

100

1000

1.0E-09 1.0E-07 1.0E-05 1.0E-03 1.0E-01 1.0E+01 1.0E+03

hE(

W),

h*

(p

Sv c

m2 )

Neutron Energy (MeV)

AP

PA

LLAT

RLAT

ISO

ROT

H*

Effective dose E vs.

Ambient Dose equivalent H*(10) Effective dose E vs.

Ambient Dose H*

10

Page 11: ICRU Report 95 - nucleus-new.iaea.org

Personal dose – photonsConversion coefficients from kerma Ka to operational quantity

Th. Otto - ICRU Report 95 - IAEA ORPAS - 17. 9. 2021

𝐻p ≈1

5𝐻p(10)

𝐻p ≈ 0.86 𝐻p(10)

At energies typical for radioisotopes, Hp = 0.86 * Hp(10)

At low-energy x-ray (backscatter from patient) Hp = 0.2 * Hp(10)

11

Page 12: ICRU Report 95 - nucleus-new.iaea.org

Activation products

Activation with 3.5 GeV proton beam

Photon and electron spectra (1h decay)

H*(10) and H* overlay

Ratio H* / H*(10)

• Photons dominate

• H* < H*(10) by 15 %

• Typical for radionuclides

• Attention for pure b-emitters

Th. Otto - ICRU Report 95 - IAEA ORPAS - 17. 9. 2021

photons

electrons

12

Page 13: ICRU Report 95 - nucleus-new.iaea.org

Low-energy x-ray spectra

Th. Otto - ICRU Report 95 - IAEA ORPAS - 17. 9. 2021

High-dose rate spectrum, 20 kV

tube voltage

Fluence spectrum

H*(10)-weigthed spectrum

H*-weighted spectrum

Diagnostic x-ray calibration

spectra

Upper curve: H*(10)

Lower curve: H*

Influence on dose of medical personnel during interventional radiology under study

13

Page 14: ICRU Report 95 - nucleus-new.iaea.org

Prompt radiation at a particle accelerator (160 MeV protons)

• Behind the dump: high-energy particles, H* ≥ H*(10)

• In Front: multiple scattered neutrons: H* < H*(10)

• Analogue results for proton therapy accelerators

Th. Otto - ICRU Report 95 - IAEA ORPAS - 17. 9. 2021 14

Page 15: ICRU Report 95 - nucleus-new.iaea.org

Consequences for Dose Registers

• Dose registers (should) record effective dose E

• New quantities: closer approximation to E

• For most workers, where monthly dose is (close

to) zero, no difference

• Measurement uncertainty at low dose (trumpet

curve) !

• Recorded value for workers with significant dose

will be slightly lower

• Case of medical staff in Interventional Radiology

needs to be studied in more detail

Th. Otto - ICRU Report 95 - IAEA ORPAS - 17. 9. 2021 15

Page 16: ICRU Report 95 - nucleus-new.iaea.org

ICRU 95 – Consequences for Photon Dosimeters

Area monitoring

instruments with energy

cut-off > 50 keV nearly

unaffected

Simple recalibration of

sensitivity

Today’s personal

dosimeters would show

overresponse at low

photon energies

Redesign of filter required

(or algorithm for multi-

detector types)

T. Otto 2019 JINST 14 P01010

Th. Otto - ICRU Report 95 - IAEA ORPAS - 17. 9. 2021

(ICRU95)

16

Page 17: ICRU Report 95 - nucleus-new.iaea.org

ICRU 95 – Consequences for Neutron Monitors

J S Eakins et al 2018 J. Radiol. Prot. 38 688

Black lines: IEC 61005 Ed. 3.0 b:2014

recommended response interval

Re-assessment of IEC acceptance

regions required

As previously, standard Rem-counter

response in mono-energetic fields within a

large factor

No significant change for use at Ekin < 20 MeV

Field calibration may be necessary

Th. Otto - ICRU Report 95 - IAEA ORPAS - 17. 9. 2021 17

Page 18: ICRU Report 95 - nucleus-new.iaea.org

ICRU 95 – Conclusion

• New operational quantities are defined in a consistent manner to the protection quantities

• Numerical values and their trends with energy are coherent with protection quantities

• System of quantities is easier to understand

• Adaptation of certain dosimeter types required: • Personal dosimeters for g and b radiation at low

energy

Th. Otto - ICRU Report 95 - IAEA ORPAS - 17. 9. 2021 18

Page 19: ICRU Report 95 - nucleus-new.iaea.org

Thank you for your Attention

Page 20: ICRU Report 95 - nucleus-new.iaea.org

Spare slides

Page 21: ICRU Report 95 - nucleus-new.iaea.org

Response of dosimeters

• Response: 𝑅 =𝐺

𝐶

• Dose Indication G /Conventional true value C

• Change of quantity: Cold →Cnew

• Dose indication remains the same: G →G

• Response of dosimeter in the new quantity:

𝑅new =𝐺

𝐶old

𝐶old𝐶new

= 𝑅𝑜𝑙𝑑𝐶old𝐶new

= 𝑅𝑜𝑙𝑑ℎoldℎnew

Th. Otto - ICRU Report 95 - IAEA ORPAS - 17. 9. 2021 21

Page 22: ICRU Report 95 - nucleus-new.iaea.org

Response of Survey instrument

Th. Otto - ICRU Report 95 - IAEA ORPAS - 17. 9. 2021

Recalibration at

reference point

22

Page 23: ICRU Report 95 - nucleus-new.iaea.org

Response of Ionisation chamber

Th. Otto - ICRU Report 95 - IAEA ORPAS - 17. 9. 2021 23

Page 24: ICRU Report 95 - nucleus-new.iaea.org

Response of personal dosimeter 1

Th. Otto - ICRU Report 95 - IAEA ORPAS - 17. 9. 2021 24

Page 25: ICRU Report 95 - nucleus-new.iaea.org

Response of personal dosimeter 2

Th. Otto - ICRU Report 95 - IAEA ORPAS - 17. 9. 2021 25

Page 26: ICRU Report 95 - nucleus-new.iaea.org

Personal dose to local skin

Th. Otto - ICRU Report 95 - IAEA ORPAS - 17. 9. 2021

← Region of practical interest →

Due to similar phantom Hp(0.07) and Dlocal skin are numerically similar.

26

Page 27: ICRU Report 95 - nucleus-new.iaea.org

Response of “skin” dosimeters

Th. Otto - ICRU Report 95 - IAEA ORPAS - 17. 9. 2021

• Similar calculation

phantoms for the

conversion coefficients to

Dlocal skin and Hp(0.07)

• Existing dosimeter

elements for Hp(0.07) will

give very good reading of

Dlocal skin

27

Page 28: ICRU Report 95 - nucleus-new.iaea.org

Dosimeter Response - Findings• Survey monitors can be re-calibrated in ambient

dose H* without loss of measuring capability• Reason: sensitivity cutoff at Ep < 50 keV

• Survey meters for low energy photons must be investigated separately

• Personal dosimeters show overresponse to personal dose Hp at low photon energies• Reason: Hp(10) > E ≈ Hp

• Possible solutions:• Multi-detector dosimeters: change of algorithm

• Single detector dosimeters: reconstruct holder

• For more details: arxiv:1809.08680v2 [physics.ins-det]

Th. Otto - ICRU Report 95 - IAEA ORPAS - 17. 9. 2021 28