76
Daniel De Backer Department of Intensive Care Erasme University Hospital Brussels, Belgium IDIOSYNCRASIES OF HEMODYNAMIC MONITORING OF SEPTIC PATIENTS UNDER ECMO

IDIOSYNCRASIES OF HEMODYNAMIC … De Backer_01.pdfIDIOSYNCRASIES OF HEMODYNAMIC MONITORING OF ... (after mixing) SVC cannula SvcO2 Not reliable ... ScvO2 PO2 (PO2 upper

Embed Size (px)

Citation preview

Page 1: IDIOSYNCRASIES OF HEMODYNAMIC … De Backer_01.pdfIDIOSYNCRASIES OF HEMODYNAMIC MONITORING OF ... (after mixing) SVC cannula SvcO2 Not reliable ... ScvO2 PO2 (PO2 upper

Daniel De Backer

Department of Intensive Care

Erasme University Hospital

Brussels, Belgium

IDIOSYNCRASIES OF

HEMODYNAMIC MONITORING OF

SEPTIC PATIENTS UNDER ECMO

Page 2: IDIOSYNCRASIES OF HEMODYNAMIC … De Backer_01.pdfIDIOSYNCRASIES OF HEMODYNAMIC MONITORING OF ... (after mixing) SVC cannula SvcO2 Not reliable ... ScvO2 PO2 (PO2 upper

Hemodynamic monitoring in patients with sepsis

Cardiac output

Cardiac function

Volume status and preload responsiveness

PAP

SvO2

TOOLS:

PAC

Transpulmonary thermodilution

Echocardiography

NIRS

Page 3: IDIOSYNCRASIES OF HEMODYNAMIC … De Backer_01.pdfIDIOSYNCRASIES OF HEMODYNAMIC MONITORING OF ... (after mixing) SVC cannula SvcO2 Not reliable ... ScvO2 PO2 (PO2 upper

ECMO

Veno Arterial Veno Venous

Page 4: IDIOSYNCRASIES OF HEMODYNAMIC … De Backer_01.pdfIDIOSYNCRASIES OF HEMODYNAMIC MONITORING OF ... (after mixing) SVC cannula SvcO2 Not reliable ... ScvO2 PO2 (PO2 upper

VenoArterial

Blood drained from venous

compartment and injected into artery

Page 5: IDIOSYNCRASIES OF HEMODYNAMIC … De Backer_01.pdfIDIOSYNCRASIES OF HEMODYNAMIC MONITORING OF ... (after mixing) SVC cannula SvcO2 Not reliable ... ScvO2 PO2 (PO2 upper

VenoVenous

Blood drained from venous

compartment and reinjected in

venous compartment

Page 6: IDIOSYNCRASIES OF HEMODYNAMIC … De Backer_01.pdfIDIOSYNCRASIES OF HEMODYNAMIC MONITORING OF ... (after mixing) SVC cannula SvcO2 Not reliable ... ScvO2 PO2 (PO2 upper

ECMO

• Blood drained from venous

compartment and

reinjected in venous

compartment

• Respiratory support only

(02 and CO2)

• Blood drained from

venous compartment and

injected into artery

• Cardiac and respiratory

support

Veno Arterial Veno Venous

Page 7: IDIOSYNCRASIES OF HEMODYNAMIC … De Backer_01.pdfIDIOSYNCRASIES OF HEMODYNAMIC MONITORING OF ... (after mixing) SVC cannula SvcO2 Not reliable ... ScvO2 PO2 (PO2 upper

Which indications in septic patients?

ECMO

Respiratory support for severe ARDS

Circulatory support for severe myocardial depression

Page 8: IDIOSYNCRASIES OF HEMODYNAMIC … De Backer_01.pdfIDIOSYNCRASIES OF HEMODYNAMIC MONITORING OF ... (after mixing) SVC cannula SvcO2 Not reliable ... ScvO2 PO2 (PO2 upper

PaO2 depends on ECMO BF/pulmonary BF

ECMO BF 4L/min SO2 100%

Patient SvO2 50%

Lung oxygenation +10%

Total BF 5L/min:

4l x100 + 1l x50 = 5l 90% (PA)

=> SaO2 99%

Total BF 8L/min:

4l x100 + 4l x50 = 8l 75%

=> SaO2 85%

Page 9: IDIOSYNCRASIES OF HEMODYNAMIC … De Backer_01.pdfIDIOSYNCRASIES OF HEMODYNAMIC MONITORING OF ... (after mixing) SVC cannula SvcO2 Not reliable ... ScvO2 PO2 (PO2 upper

Schmidt A et al

ICM 2013 ECMO flow / CO

Page 10: IDIOSYNCRASIES OF HEMODYNAMIC … De Backer_01.pdfIDIOSYNCRASIES OF HEMODYNAMIC MONITORING OF ... (after mixing) SVC cannula SvcO2 Not reliable ... ScvO2 PO2 (PO2 upper

CESAR trial Peek G et al

Lancet 374:1351; 2009

180 pts svere ARDS (PF ratio ~75)

Page 11: IDIOSYNCRASIES OF HEMODYNAMIC … De Backer_01.pdfIDIOSYNCRASIES OF HEMODYNAMIC MONITORING OF ... (after mixing) SVC cannula SvcO2 Not reliable ... ScvO2 PO2 (PO2 upper

ANZ ECMO

JAMA 302:1535;2009

June 01 – AUG 31; 2009 15 ECMO units

ECMO in H1N1

Page 12: IDIOSYNCRASIES OF HEMODYNAMIC … De Backer_01.pdfIDIOSYNCRASIES OF HEMODYNAMIC MONITORING OF ... (after mixing) SVC cannula SvcO2 Not reliable ... ScvO2 PO2 (PO2 upper

Noah et al

JAMA 306:1659;2011 UK H1N1 cohort

Page 13: IDIOSYNCRASIES OF HEMODYNAMIC … De Backer_01.pdfIDIOSYNCRASIES OF HEMODYNAMIC MONITORING OF ... (after mixing) SVC cannula SvcO2 Not reliable ... ScvO2 PO2 (PO2 upper

CCM 2013

Page 14: IDIOSYNCRASIES OF HEMODYNAMIC … De Backer_01.pdfIDIOSYNCRASIES OF HEMODYNAMIC MONITORING OF ... (after mixing) SVC cannula SvcO2 Not reliable ... ScvO2 PO2 (PO2 upper

Brechot N et al

CCM 2013

Page 15: IDIOSYNCRASIES OF HEMODYNAMIC … De Backer_01.pdfIDIOSYNCRASIES OF HEMODYNAMIC MONITORING OF ... (after mixing) SVC cannula SvcO2 Not reliable ... ScvO2 PO2 (PO2 upper

Harlequin Syndrome

Page 16: IDIOSYNCRASIES OF HEMODYNAMIC … De Backer_01.pdfIDIOSYNCRASIES OF HEMODYNAMIC MONITORING OF ... (after mixing) SVC cannula SvcO2 Not reliable ... ScvO2 PO2 (PO2 upper

Hemodynamic monitoring in patients with sepsis

under ECMO

Cardiac output

Cardiac function

Volume status and preload responsiveness

PAP

SvO2

PO2

(PO2 upper/lower body) TOOLS ????

PAC

Transpulmonary thermodilution

Echocardiography

NIRS

Page 17: IDIOSYNCRASIES OF HEMODYNAMIC … De Backer_01.pdfIDIOSYNCRASIES OF HEMODYNAMIC MONITORING OF ... (after mixing) SVC cannula SvcO2 Not reliable ... ScvO2 PO2 (PO2 upper

Hemodynamic monitoring in patients with sepsis

under ECMO

Cardiac output

Cardiac function

Volume status

Preload responsiveness

PAP

SvO2

PO2

(PO2 upper/lower body)

PAC

Page 18: IDIOSYNCRASIES OF HEMODYNAMIC … De Backer_01.pdfIDIOSYNCRASIES OF HEMODYNAMIC MONITORING OF ... (after mixing) SVC cannula SvcO2 Not reliable ... ScvO2 PO2 (PO2 upper

Technical issues with PAC during ECMO

Loss of indicator (ouflow cannula)

Page 19: IDIOSYNCRASIES OF HEMODYNAMIC … De Backer_01.pdfIDIOSYNCRASIES OF HEMODYNAMIC MONITORING OF ... (after mixing) SVC cannula SvcO2 Not reliable ... ScvO2 PO2 (PO2 upper

DC ~ area-1

Thermodilution

Page 20: IDIOSYNCRASIES OF HEMODYNAMIC … De Backer_01.pdfIDIOSYNCRASIES OF HEMODYNAMIC MONITORING OF ... (after mixing) SVC cannula SvcO2 Not reliable ... ScvO2 PO2 (PO2 upper

DC ~ area-1

Thermodilution

Page 21: IDIOSYNCRASIES OF HEMODYNAMIC … De Backer_01.pdfIDIOSYNCRASIES OF HEMODYNAMIC MONITORING OF ... (after mixing) SVC cannula SvcO2 Not reliable ... ScvO2 PO2 (PO2 upper

Technical issues with PAC during ECMO

Loss of indicator (outflow cannula)

Dilution by a large amount of blood at a given

temperature (inflow cannula)

=> Cardiac output can be overestimated as

well as underestimated

Page 22: IDIOSYNCRASIES OF HEMODYNAMIC … De Backer_01.pdfIDIOSYNCRASIES OF HEMODYNAMIC MONITORING OF ... (after mixing) SVC cannula SvcO2 Not reliable ... ScvO2 PO2 (PO2 upper

Technical issues with PAC during ECMO

Loss of indicator (outflow cannula)

Dilution by a large amount of blood at a given

temperature (inflow cannula)

Risks associated with PAC during ECMO

Difficulties of insertion

(aspiration in outflow cannula)

Thrombosis of PA (VA ECMO only)

Page 23: IDIOSYNCRASIES OF HEMODYNAMIC … De Backer_01.pdfIDIOSYNCRASIES OF HEMODYNAMIC MONITORING OF ... (after mixing) SVC cannula SvcO2 Not reliable ... ScvO2 PO2 (PO2 upper

Pros and Cons of PAC during ECMO

Measurements of PAOP and PAP

SvO2

Cons

Cardiac output not reliable

Difficulties of insertion (aspiration in outflow

cannula)

Thrombosis of PA (VA ECMO only)

Pros

Page 24: IDIOSYNCRASIES OF HEMODYNAMIC … De Backer_01.pdfIDIOSYNCRASIES OF HEMODYNAMIC MONITORING OF ... (after mixing) SVC cannula SvcO2 Not reliable ... ScvO2 PO2 (PO2 upper

RV LV

SvO2Brain

Skin

Muscle

Kidney

Gut /

Liver

Heart

normal valuearound 70 %ECMO

3-4 L/min

SO2 100%

SvO2~90%

Page 25: IDIOSYNCRASIES OF HEMODYNAMIC … De Backer_01.pdfIDIOSYNCRASIES OF HEMODYNAMIC MONITORING OF ... (after mixing) SVC cannula SvcO2 Not reliable ... ScvO2 PO2 (PO2 upper

Interpretation of SvO2 in VV ECMO

IVC cannula

SVC

PA

SvcO2 = adequacy

of flow

SvO2 = efficiency

of ECMO

(after mixing)

SVC cannula

SvcO2

Not reliable

(= efficacy SO2)

Page 26: IDIOSYNCRASIES OF HEMODYNAMIC … De Backer_01.pdfIDIOSYNCRASIES OF HEMODYNAMIC MONITORING OF ... (after mixing) SVC cannula SvcO2 Not reliable ... ScvO2 PO2 (PO2 upper

Hemodynamic monitoring in patients with sepsis

under ECMO

Cardiac output ???

Cardiac function ????

Volume status

Preload responsiveness

PAP

SvO2

PO2

(PO2 upper/lower body)

PAC

Page 27: IDIOSYNCRASIES OF HEMODYNAMIC … De Backer_01.pdfIDIOSYNCRASIES OF HEMODYNAMIC MONITORING OF ... (after mixing) SVC cannula SvcO2 Not reliable ... ScvO2 PO2 (PO2 upper

Hemodynamic monitoring in patients with sepsis

under ECMO

Cardiac output

Cardiac function

Volume status

Preload responsiveness

ScvO2

PO2

(PO2 upper/lower body)

TPD +

pulse contour

Page 28: IDIOSYNCRASIES OF HEMODYNAMIC … De Backer_01.pdfIDIOSYNCRASIES OF HEMODYNAMIC MONITORING OF ... (after mixing) SVC cannula SvcO2 Not reliable ... ScvO2 PO2 (PO2 upper

Technical issues with transpulmonary

thermodilution and pulse contour during ECMO

Loss of indicator (outflow cannula)

Dilution by large amount of blood at a given

temperature (inflow cannula)

=> Cardiac output can be overestimated as

well as underestimated

=> GEDV and EVLW are not reliable

anymore!

Page 29: IDIOSYNCRASIES OF HEMODYNAMIC … De Backer_01.pdfIDIOSYNCRASIES OF HEMODYNAMIC MONITORING OF ... (after mixing) SVC cannula SvcO2 Not reliable ... ScvO2 PO2 (PO2 upper

Pros and Cons of transpulmonary

thermodilution and pulse contour during ECMO

??

Cons

Cardiac output not reliable

Derived measurements not reliable

(GEDV, EVLW,…)

Pulse contour not feasible in VA ECMO

Pros

Page 30: IDIOSYNCRASIES OF HEMODYNAMIC … De Backer_01.pdfIDIOSYNCRASIES OF HEMODYNAMIC MONITORING OF ... (after mixing) SVC cannula SvcO2 Not reliable ... ScvO2 PO2 (PO2 upper

Hemodynamic monitoring in patients with sepsis

under ECMO

Cardiac output

Cardiac function

Volume status

Preload responsiveness

ScvO2

PO2

(PO2 upper/lower body)

TPD +

pulse contour

Page 31: IDIOSYNCRASIES OF HEMODYNAMIC … De Backer_01.pdfIDIOSYNCRASIES OF HEMODYNAMIC MONITORING OF ... (after mixing) SVC cannula SvcO2 Not reliable ... ScvO2 PO2 (PO2 upper

Hemodynamic monitoring in patients with sepsis

under ECMO

ECHOCARDIOGRAPHY

Page 32: IDIOSYNCRASIES OF HEMODYNAMIC … De Backer_01.pdfIDIOSYNCRASIES OF HEMODYNAMIC MONITORING OF ... (after mixing) SVC cannula SvcO2 Not reliable ... ScvO2 PO2 (PO2 upper

Hemodynamic monitoring in patients with sepsis

under ECMO

Cardiac output

Cardiac function

Volume status

Preload responsiveness

PAP

SvO2

PO2

(PO2 upper/lower body)

ECHOCARDIOGRAPHY

Page 33: IDIOSYNCRASIES OF HEMODYNAMIC … De Backer_01.pdfIDIOSYNCRASIES OF HEMODYNAMIC MONITORING OF ... (after mixing) SVC cannula SvcO2 Not reliable ... ScvO2 PO2 (PO2 upper

Veno-venous

ECMO

Check correctable factors before ECMO

Position of cannulas

Evaluation of RV function

Cardiac output measurements

Page 34: IDIOSYNCRASIES OF HEMODYNAMIC … De Backer_01.pdfIDIOSYNCRASIES OF HEMODYNAMIC MONITORING OF ... (after mixing) SVC cannula SvcO2 Not reliable ... ScvO2 PO2 (PO2 upper

Echo in veno-venous ECMO

Check for reversible factors prior to ECMO

PFO

Large pleural effusion

Page 35: IDIOSYNCRASIES OF HEMODYNAMIC … De Backer_01.pdfIDIOSYNCRASIES OF HEMODYNAMIC MONITORING OF ... (after mixing) SVC cannula SvcO2 Not reliable ... ScvO2 PO2 (PO2 upper
Page 36: IDIOSYNCRASIES OF HEMODYNAMIC … De Backer_01.pdfIDIOSYNCRASIES OF HEMODYNAMIC MONITORING OF ... (after mixing) SVC cannula SvcO2 Not reliable ... ScvO2 PO2 (PO2 upper

Large pleural effusion (Right)

Page 37: IDIOSYNCRASIES OF HEMODYNAMIC … De Backer_01.pdfIDIOSYNCRASIES OF HEMODYNAMIC MONITORING OF ... (after mixing) SVC cannula SvcO2 Not reliable ... ScvO2 PO2 (PO2 upper

Position of cannulas in VV ECMO

• Two types of cannulations

Dual cannulation

Double lumen cannula

Page 38: IDIOSYNCRASIES OF HEMODYNAMIC … De Backer_01.pdfIDIOSYNCRASIES OF HEMODYNAMIC MONITORING OF ... (after mixing) SVC cannula SvcO2 Not reliable ... ScvO2 PO2 (PO2 upper

Dual cannulation

• The position of the IVC cannula should

be carefully checked

(good drainage / no recirculation)

• The SVC cannula is usually not visualized

Page 39: IDIOSYNCRASIES OF HEMODYNAMIC … De Backer_01.pdfIDIOSYNCRASIES OF HEMODYNAMIC MONITORING OF ... (after mixing) SVC cannula SvcO2 Not reliable ... ScvO2 PO2 (PO2 upper

Dual cannulation Brodie D et al

NEJM 365:1905;2011

Page 40: IDIOSYNCRASIES OF HEMODYNAMIC … De Backer_01.pdfIDIOSYNCRASIES OF HEMODYNAMIC MONITORING OF ... (after mixing) SVC cannula SvcO2 Not reliable ... ScvO2 PO2 (PO2 upper

Dual cannulation

IVC cannula

SVC cannula

Page 41: IDIOSYNCRASIES OF HEMODYNAMIC … De Backer_01.pdfIDIOSYNCRASIES OF HEMODYNAMIC MONITORING OF ... (after mixing) SVC cannula SvcO2 Not reliable ... ScvO2 PO2 (PO2 upper

Retrieval of IVC cannula under echo guidance

Page 42: IDIOSYNCRASIES OF HEMODYNAMIC … De Backer_01.pdfIDIOSYNCRASIES OF HEMODYNAMIC MONITORING OF ... (after mixing) SVC cannula SvcO2 Not reliable ... ScvO2 PO2 (PO2 upper

IVC cannula repositioned

Page 43: IDIOSYNCRASIES OF HEMODYNAMIC … De Backer_01.pdfIDIOSYNCRASIES OF HEMODYNAMIC MONITORING OF ... (after mixing) SVC cannula SvcO2 Not reliable ... ScvO2 PO2 (PO2 upper

IVC cannula slightly too much withdrawn

Page 44: IDIOSYNCRASIES OF HEMODYNAMIC … De Backer_01.pdfIDIOSYNCRASIES OF HEMODYNAMIC MONITORING OF ... (after mixing) SVC cannula SvcO2 Not reliable ... ScvO2 PO2 (PO2 upper

Liver

IVC Right atrium

The best position

Page 45: IDIOSYNCRASIES OF HEMODYNAMIC … De Backer_01.pdfIDIOSYNCRASIES OF HEMODYNAMIC MONITORING OF ... (after mixing) SVC cannula SvcO2 Not reliable ... ScvO2 PO2 (PO2 upper
Page 46: IDIOSYNCRASIES OF HEMODYNAMIC … De Backer_01.pdfIDIOSYNCRASIES OF HEMODYNAMIC MONITORING OF ... (after mixing) SVC cannula SvcO2 Not reliable ... ScvO2 PO2 (PO2 upper
Page 47: IDIOSYNCRASIES OF HEMODYNAMIC … De Backer_01.pdfIDIOSYNCRASIES OF HEMODYNAMIC MONITORING OF ... (after mixing) SVC cannula SvcO2 Not reliable ... ScvO2 PO2 (PO2 upper
Page 48: IDIOSYNCRASIES OF HEMODYNAMIC … De Backer_01.pdfIDIOSYNCRASIES OF HEMODYNAMIC MONITORING OF ... (after mixing) SVC cannula SvcO2 Not reliable ... ScvO2 PO2 (PO2 upper

Double lumen cannula Brodie D et al

NEJM 365:1905;2011

Page 49: IDIOSYNCRASIES OF HEMODYNAMIC … De Backer_01.pdfIDIOSYNCRASIES OF HEMODYNAMIC MONITORING OF ... (after mixing) SVC cannula SvcO2 Not reliable ... ScvO2 PO2 (PO2 upper

Körver E et al

ICM 38:906;2012

Page 50: IDIOSYNCRASIES OF HEMODYNAMIC … De Backer_01.pdfIDIOSYNCRASIES OF HEMODYNAMIC MONITORING OF ... (after mixing) SVC cannula SvcO2 Not reliable ... ScvO2 PO2 (PO2 upper

Hirose H et al

J Cardiovasc Surgery

7:36;2012

Page 51: IDIOSYNCRASIES OF HEMODYNAMIC … De Backer_01.pdfIDIOSYNCRASIES OF HEMODYNAMIC MONITORING OF ... (after mixing) SVC cannula SvcO2 Not reliable ... ScvO2 PO2 (PO2 upper

Echo in veno-venous ECMO

Check for reversible factor prior to ECMO

Position of cannulas

Evaluation of RV function

(before / during run / during weaning)

Cardiac output measurements

Filling pressures / PAP

Fluid responsiveness

Check for thrombi around cannulas

Page 52: IDIOSYNCRASIES OF HEMODYNAMIC … De Backer_01.pdfIDIOSYNCRASIES OF HEMODYNAMIC MONITORING OF ... (after mixing) SVC cannula SvcO2 Not reliable ... ScvO2 PO2 (PO2 upper

Guinot et al

Crit Care 15:R216;2011

N=25

Page 53: IDIOSYNCRASIES OF HEMODYNAMIC … De Backer_01.pdfIDIOSYNCRASIES OF HEMODYNAMIC MONITORING OF ... (after mixing) SVC cannula SvcO2 Not reliable ... ScvO2 PO2 (PO2 upper

Guinot et al

Crit Care 15:R216;2011

N=25

Page 54: IDIOSYNCRASIES OF HEMODYNAMIC … De Backer_01.pdfIDIOSYNCRASIES OF HEMODYNAMIC MONITORING OF ... (after mixing) SVC cannula SvcO2 Not reliable ... ScvO2 PO2 (PO2 upper

Thrombi around IVC cannula

Page 55: IDIOSYNCRASIES OF HEMODYNAMIC … De Backer_01.pdfIDIOSYNCRASIES OF HEMODYNAMIC MONITORING OF ... (after mixing) SVC cannula SvcO2 Not reliable ... ScvO2 PO2 (PO2 upper

Echocardiography in veno-arterial ECMO

• Before ECMO:

• Evaluation of indication and exclusion of

correctable causes of cardiogenic shock

• Evaluation of aorta and aortic valve

Page 56: IDIOSYNCRASIES OF HEMODYNAMIC … De Backer_01.pdfIDIOSYNCRASIES OF HEMODYNAMIC MONITORING OF ... (after mixing) SVC cannula SvcO2 Not reliable ... ScvO2 PO2 (PO2 upper

Echocardiography in veno-arterial ECMO

• Before ECMO:

• During ECMO insertion:

• Position of guidewires and cannulas

Page 57: IDIOSYNCRASIES OF HEMODYNAMIC … De Backer_01.pdfIDIOSYNCRASIES OF HEMODYNAMIC MONITORING OF ... (after mixing) SVC cannula SvcO2 Not reliable ... ScvO2 PO2 (PO2 upper

VA ECMO

Top of venous cannula in RA

• No risk of recirculation

• Avoid risk of IVC collapse

Page 58: IDIOSYNCRASIES OF HEMODYNAMIC … De Backer_01.pdfIDIOSYNCRASIES OF HEMODYNAMIC MONITORING OF ... (after mixing) SVC cannula SvcO2 Not reliable ... ScvO2 PO2 (PO2 upper

IVC cannula positioned

Page 59: IDIOSYNCRASIES OF HEMODYNAMIC … De Backer_01.pdfIDIOSYNCRASIES OF HEMODYNAMIC MONITORING OF ... (after mixing) SVC cannula SvcO2 Not reliable ... ScvO2 PO2 (PO2 upper

Kinked cannula (high lateral velocities/ no tip velocity)

Pump: 8500 RPM

Calderon et al

Hemodynamic monitoring using

echocardiography in the critically ill

Eds: De Backer et al

Springer 2011

Page 60: IDIOSYNCRASIES OF HEMODYNAMIC … De Backer_01.pdfIDIOSYNCRASIES OF HEMODYNAMIC MONITORING OF ... (after mixing) SVC cannula SvcO2 Not reliable ... ScvO2 PO2 (PO2 upper

Cannula withdrawn

Calderon et al

Hemodynamic monitoring using

echocardiography in the critically ill

Eds: De Backer et al

Springer 2011

Page 61: IDIOSYNCRASIES OF HEMODYNAMIC … De Backer_01.pdfIDIOSYNCRASIES OF HEMODYNAMIC MONITORING OF ... (after mixing) SVC cannula SvcO2 Not reliable ... ScvO2 PO2 (PO2 upper

Echocardiography in veno-arterial ECMO

• Before ECMO:

•During ECMO insertion:

• During ECMO run:

• Evaluation of RV / LV function

• Aortic regurgitation ?

• LV ballooning / pulmonary edema

• Cardiac output measurements

• Detection of thrombus

• Weaning

Page 62: IDIOSYNCRASIES OF HEMODYNAMIC … De Backer_01.pdfIDIOSYNCRASIES OF HEMODYNAMIC MONITORING OF ... (after mixing) SVC cannula SvcO2 Not reliable ... ScvO2 PO2 (PO2 upper

Descending aorta blood flow

Calderon et al

Hemodynamic monitoring using

echocardiography in the critically ill

Eds: De Backer et al

Springer 2011

Increased LV afterload

Page 63: IDIOSYNCRASIES OF HEMODYNAMIC … De Backer_01.pdfIDIOSYNCRASIES OF HEMODYNAMIC MONITORING OF ... (after mixing) SVC cannula SvcO2 Not reliable ... ScvO2 PO2 (PO2 upper

Large A wave on pulmonary vein flow => elevated PAOP

Calderon et al

Hemodynamic monitoring using

echocardiography in the critically ill

Eds: De Backer et al

Springer 2011

Page 64: IDIOSYNCRASIES OF HEMODYNAMIC … De Backer_01.pdfIDIOSYNCRASIES OF HEMODYNAMIC MONITORING OF ... (after mixing) SVC cannula SvcO2 Not reliable ... ScvO2 PO2 (PO2 upper

E

Abnormal mitral flow waves (backflow!)

A (biphasic with diastolic backflow)

Mitral regurgitation

Calderon et al

Hemodynamic monitoring using

echocardiography in the critically ill

Eds: De Backer et al

Springer 2011

Page 65: IDIOSYNCRASIES OF HEMODYNAMIC … De Backer_01.pdfIDIOSYNCRASIES OF HEMODYNAMIC MONITORING OF ... (after mixing) SVC cannula SvcO2 Not reliable ... ScvO2 PO2 (PO2 upper

Risk for clotting

Page 66: IDIOSYNCRASIES OF HEMODYNAMIC … De Backer_01.pdfIDIOSYNCRASIES OF HEMODYNAMIC MONITORING OF ... (after mixing) SVC cannula SvcO2 Not reliable ... ScvO2 PO2 (PO2 upper

Echo for weaning of ECMO

• VV ECMO: Check RV

• VA ECMO: Check RV/LV/VTI/filling pressures

Page 67: IDIOSYNCRASIES OF HEMODYNAMIC … De Backer_01.pdfIDIOSYNCRASIES OF HEMODYNAMIC MONITORING OF ... (after mixing) SVC cannula SvcO2 Not reliable ... ScvO2 PO2 (PO2 upper

Female 46 YO AMI

• Admitted for AMI

• Hemodynamically stable

• Immediate coronary arteries angiography

• During revascularization attempt, the patient

developped cardiac arrest (VF => EMD)

• Implantation of ECMO for eCPR

• Revascularization effective

Page 68: IDIOSYNCRASIES OF HEMODYNAMIC … De Backer_01.pdfIDIOSYNCRASIES OF HEMODYNAMIC MONITORING OF ... (after mixing) SVC cannula SvcO2 Not reliable ... ScvO2 PO2 (PO2 upper

Measurements of Ao VTI for ECMO weaning

Page 69: IDIOSYNCRASIES OF HEMODYNAMIC … De Backer_01.pdfIDIOSYNCRASIES OF HEMODYNAMIC MONITORING OF ... (after mixing) SVC cannula SvcO2 Not reliable ... ScvO2 PO2 (PO2 upper

Measurements of Ao VTI for ECMO weaning

Page 70: IDIOSYNCRASIES OF HEMODYNAMIC … De Backer_01.pdfIDIOSYNCRASIES OF HEMODYNAMIC MONITORING OF ... (after mixing) SVC cannula SvcO2 Not reliable ... ScvO2 PO2 (PO2 upper

Measurements of Ao VTI for ECMO weaning

Page 71: IDIOSYNCRASIES OF HEMODYNAMIC … De Backer_01.pdfIDIOSYNCRASIES OF HEMODYNAMIC MONITORING OF ... (after mixing) SVC cannula SvcO2 Not reliable ... ScvO2 PO2 (PO2 upper

Echo for weaning

of ECMO

Aissaoui N et al

ICM 37:1738;2011

ECMO n=33

Weaned

Failed

Page 72: IDIOSYNCRASIES OF HEMODYNAMIC … De Backer_01.pdfIDIOSYNCRASIES OF HEMODYNAMIC MONITORING OF ... (after mixing) SVC cannula SvcO2 Not reliable ... ScvO2 PO2 (PO2 upper

Echo for weaning

of ECMO

Aissaoui N et al

ICM 37:1738;2011

ECMO n=33

Weaned

Failed

VTI > 10-12 cm

TDSa > 6 cm/s

LVEF > 20-25%

Page 73: IDIOSYNCRASIES OF HEMODYNAMIC … De Backer_01.pdfIDIOSYNCRASIES OF HEMODYNAMIC MONITORING OF ... (after mixing) SVC cannula SvcO2 Not reliable ... ScvO2 PO2 (PO2 upper

Hemodynamic monitoring in patients with sepsis

under ECMO

Cardiac output

Cardiac function

Volume status

Preload responsiveness

PAP

SvO2

PO2

(PO2 upper/lower body)

ECHOCARDIOGRAPHY

Page 74: IDIOSYNCRASIES OF HEMODYNAMIC … De Backer_01.pdfIDIOSYNCRASIES OF HEMODYNAMIC MONITORING OF ... (after mixing) SVC cannula SvcO2 Not reliable ... ScvO2 PO2 (PO2 upper

A place for regional O2 saturations monitoring in VA ECMO

Left cerebral

Right cerebral

Left leg

Right leg

Wong JS et al

ASAIO 36:659;2012

Page 75: IDIOSYNCRASIES OF HEMODYNAMIC … De Backer_01.pdfIDIOSYNCRASIES OF HEMODYNAMIC MONITORING OF ... (after mixing) SVC cannula SvcO2 Not reliable ... ScvO2 PO2 (PO2 upper

Which hemodynamic monitoring in patients

with sepsis under ECMO ?

Echocardiography

PAC in some patients

NIRS (or equivalent) in VA ECMO

Page 76: IDIOSYNCRASIES OF HEMODYNAMIC … De Backer_01.pdfIDIOSYNCRASIES OF HEMODYNAMIC MONITORING OF ... (after mixing) SVC cannula SvcO2 Not reliable ... ScvO2 PO2 (PO2 upper

Thank you

25/04/2012 06/05/2011