ORB OPTRONIX - TEST & MEASUREMENT LABORATORY - PRODUCT REPORTIES LM-79-08 Approved Method for the Electrical and Photometric Measurements of Solid-State Lighting Products
Zone Lumens % Lamp
0-30 411.2 77.7%
0-40 460.9 87.1%
0-60 507.9 96.0%
60-90 21.4 4.0%
70-100 5.8 1.1%
90-120 0 0.0%
0-90 529.3 100%
90-180 0 0%
0-180 529.3 100%
Zonal Lumen Summary
Zone Lumens % Total
0-10 128.8 24.3%
10-20 181.7 34.3%
20-30 100.7 19.0%
30-40 49.7 9.4%
40-50 27 5.1%
50-60 20.1 3.8%
60-70 15.6 3.0%
70-80 5.8 1.1%
80-90 0 0.0%
Total 529.4 100%
Lumens Per Zone
Orb Optronix, Inc.
1003 7th
Ave
Kirkland, WA 98033 Device Ref #: P30LN-L540-C27-B25
tel: Date Issued:fax: Date Tested:
W VAC
lm x 0.4639
lm/W y 0.4155 W
nm u 0.2629 Hz
nm v 0.3532
% u' 0.2629
K v' 0.5298 K
Delta uv 0.0015 Deg
cd Hz
VAC
A
VA
W
Hz
°C
°C
%
Figure 3
0.0 ± 2 mm
0.0 ± 2 mm
1.0 ± 0.005 m
0.00 ± 0.10 Deg
337.50 ± 0.10 Deg
22.50 ± 0.10 Deg
0.00 ± 0.10 Deg
75.00 ± 0.10 Deg
Figure 4 2.50 ± 0.10 DegPhi Step Size
2691
Emitter
608.2
583.8
Total Integrated Radiant Flux
Total Integrated Luminous Flux
Peak Wavelength
Dominant Wavelength
DUT MEASUREMENT CONDITIONS
1747.9
2700
-
Color Purity
Base Up
Type C
Theta Step Size
Theta Maximum
Phi Minimum
Phi Maximum
Theta Minmum
ADDITIONAL TEST INFORMATION
77.34
532.9
CCT
CRI Ra
Peak Candela Operating Freq.
Color Temperature
Orientation
1.8
Power
Current
64.0
3/17/2011
MANUFACTURER SPECIFICATIONS
120.0
Dimmable
Voltage
37.5
425 605 8500801 912 2645
RADIOMETRIC & PHOTOMETRIC MEASUREMENT RESULTS 1
Configuration
0.71
14.21
60.06
21.2
57.4
29.8
4/16/2011
Chromaticity Coordinates
-
-
Frequency
14.7
-
Yes
Luminous Efficacy
z-axis Alignment
y-axis Alignment
x-axis Alignment
119.97
0.167
19.99
Active Power
Average Current
Device Temp
Ambient Temp
Average Voltage
Apparent Power
Power Factor
Frequency
Orientation
Humidity
0.00E+00
5.00E-03
1.00E-02
1.50E-02
2.00E-02
2.50E-02
3.00E-02
3.50E-02
380 430 480 530 580 630 680 730 780
Irra
dia
nce
(W
/m2 *
nm
)
Wavelength (nm)
Spectral Irradiance
0.00E+00
5.00E-03
1.00E-02
1.50E-02
2.00E-02
2.50E-02
3.00E-02
380 430 480 530 580 630 680 730 780
Spe
ctra
l Illu
min
ance
(lm
/m2 /
nm
)
Wavelength (nm)
Spectral Illuminance
Zone Lumens % Lamp
0-30 411.2 77.7%
0-40 460.9 87.1%
0-60 507.9 96.0%
60-90 21.4 4.0%
70-100 5.8 1.1%
90-120 0 0.0%
0-90 529.3 100%
90-180 0 0%
0-180 529.3 100%
Zonal Lumen Summary
Zone Lumens % Total
0-10 128.8 24.3%
10-20 181.7 34.3%
20-30 100.7 19.0%
30-40 49.7 9.4%
40-50 27 5.1%
50-60 20.1 3.8%
60-70 15.6 3.0%
70-80 5.8 1.1%
80-90 0 0.0%
Total 529.4 100%
Lumens Per Zone
Report Format ORB 2.0 S/G
REV: 1.0 Page 2 of 7Approved By: DWR .
INITIALS ONLY.
ORB OPTRONIX - TEST & MEASUREMENT LABORATORY - PRODUCT REPORTIES LM-79-08 Approved Method for the Electrical and Photometric Measurements of Solid-State Lighting Products
Zone Lumens % Lamp
0-30 411.2 77.7%
0-40 460.9 87.1%
0-60 507.9 96.0%
60-90 21.4 4.0%
70-100 5.8 1.1%
90-120 0 0.0%
0-90 529.3 100%
90-180 0 0%
0-180 529.3 100%
Zonal Lumen Summary
Zone Lumens % Total
0-10 128.8 24.3%
10-20 181.7 34.3%
20-30 100.7 19.0%
30-40 49.7 9.4%
40-50 27 5.1%
50-60 20.1 3.8%
60-70 15.6 3.0%
70-80 5.8 1.1%
80-90 0 0.0%
Total 529.4 100%
Lumens Per Zone
Orb Optronix, Inc.
1003 7th
Ave
Kirkland, WA 98033 Device Ref #: P30LN-L540-C27-B25
tel: Date Issued:
fax: Date Tested:
Chromaticity and Color Plots
425 605 8500
801 912 2645 3/17/2011
4/16/2011
0
500
1000
1500
2000
2500
3000
3500
0 10 20 30 40
CC
T
q (degrees)
Correlated Color Temperature (CCT) vs Angle2
0
22.5
45
67.5
90
112.5
135
157.5
180
202.5
225
CIE1931 Chromaticity Diagram
Plankian
Weighted Average
Zone Lumens % Lamp
0-30 411.2 77.7%
0-40 460.9 87.1%
0-60 507.9 96.0%
60-90 21.4 4.0%
70-100 5.8 1.1%
90-120 0 0.0%
0-90 529.3 100%
90-180 0 0%
0-180 529.3 100%
Zonal Lumen Summary
Zone Lumens % Total
0-10 128.8 24.3%
10-20 181.7 34.3%
20-30 100.7 19.0%
30-40 49.7 9.4%
40-50 27 5.1%
50-60 20.1 3.8%
60-70 15.6 3.0%
70-80 5.8 1.1%
80-90 0 0.0%
Total 529.4 100%
Lumens Per Zone
Report Format ORB 2.0 S/G
REV: 1.0 Page 3 of 7Approved By: DWR .
INITIALS ONLY.
ORB OPTRONIX - TEST & MEASUREMENT LABORATORY - PRODUCT REPORTIES LM-79-08 Approved Method for the Electrical and Photometric Measurements of Solid-State Lighting Products
Zone Lumens % Lamp
0-30 411.2 77.7%
0-40 460.9 87.1%
0-60 507.9 96.0%
60-90 21.4 4.0%
70-100 5.8 1.1%
90-120 0 0.0%
0-90 529.3 100%
90-180 0 0%
0-180 529.3 100%
Zonal Lumen Summary
Zone Lumens % Total
0-10 128.8 24.3%
10-20 181.7 34.3%
20-30 100.7 19.0%
30-40 49.7 9.4%
40-50 27 5.1%
50-60 20.1 3.8%
60-70 15.6 3.0%
70-80 5.8 1.1%
80-90 0 0.0%
Total 529.4 100%
Lumens Per Zone
Orb Optronix, Inc.
1003 7th
Ave
Kirkland, WA 98033 Device Ref #: P30LN-L540-C27-B25
tel: Date Issued:fax: Date Tested:
4/16/20113/17/2011801 912 2645
425 605 8500
0
10
20
30
40
50
60
70
80
90
100
0 10 20 30 40
CR
I
q (degrees)
Color Rendering Index (CRI) vs Angle2
0
22.5
45
67.5
90
112.5
135
157.5
180
202.5
225
Zone Lumens % Lamp
0-30 411.2 77.7%
0-40 460.9 87.1%
0-60 507.9 96.0%
60-90 21.4 4.0%
70-100 5.8 1.1%
90-120 0 0.0%
0-90 529.3 100%
90-180 0 0%
0-180 529.3 100%
Zonal Lumen Summary
Zone Lumens % Total
0-10 128.8 24.3%
10-20 181.7 34.3%
20-30 100.7 19.0%
30-40 49.7 9.4%
40-50 27 5.1%
50-60 20.1 3.8%
60-70 15.6 3.0%
70-80 5.8 1.1%
80-90 0 0.0%
Total 529.4 100%
Lumens Per Zone
Report Format ORB 2.0 S/G
REV: 1.0 Page 4 of 7Approved By: DWR .
INITIALS ONLY.
ORB OPTRONIX - TEST & MEASUREMENT LABORATORY - PRODUCT REPORTIES LM-79-08 Approved Method for the Electrical and Photometric Measurements of Solid-State Lighting Products
Zone Lumens % Lamp
0-30 411.2 77.7%
0-40 460.9 87.1%
0-60 507.9 96.0%
60-90 21.4 4.0%
70-100 5.8 1.1%
90-120 0 0.0%
0-90 529.3 100%
90-180 0 0%
0-180 529.3 100%
Zonal Lumen Summary
Zone Lumens % Total
0-10 128.8 24.3%
10-20 181.7 34.3%
20-30 100.7 19.0%
30-40 49.7 9.4%
40-50 27 5.1%
50-60 20.1 3.8%
60-70 15.6 3.0%
70-80 5.8 1.1%
80-90 0 0.0%
Total 529.4 100%
Lumens Per Zone
Orb Optronix, Inc.
1003 7th
Ave
Kirkland, WA 98033 Device Ref #: P30LN-L540-C27-B25
tel: Date Issued:fax: Date Tested:
Zonal Lumen Summary
Illuminanace Plots
425 605 8500 4/16/2011801 912 2645 3/17/2011
Zone Lumens % Lamp
0-30 411.2 77.7%
0-40 460.9 87.1%
0-60 507.9 96.0%
60-90 21.4 4.0%
70-100 5.8 1.1%
90-120 0 0.0%
0-90 529.3 100%
90-180 0 0%
0-180 529.3 100%
Zonal Lumen Summary
Zone Lumens % Total
0-10 128.8 24.3%
10-20 181.7 34.3%
20-30 100.7 19.0%
30-40 49.7 9.4%
40-50 27 5.1%
50-60 20.1 3.8%
60-70 15.6 3.0%
70-80 5.8 1.1%
80-90 0 0.0%
Total 529.4 100%
Lumens Per Zone
Report Format ORB 2.0 S/G
REV: 1.0 Page 5 of 7Approved By: DWR .
INITIALS ONLY.
ORB OPTRONIX - TEST & MEASUREMENT LABORATORY - PRODUCT REPORTIES LM-79-08 Approved Method for the Electrical and Photometric Measurements of Solid-State Lighting Products
Zone Lumens % Lamp
0-30 411.2 77.7%
0-40 460.9 87.1%
0-60 507.9 96.0%
60-90 21.4 4.0%
70-100 5.8 1.1%
90-120 0 0.0%
0-90 529.3 100%
90-180 0 0%
0-180 529.3 100%
Zonal Lumen Summary
Zone Lumens % Total
0-10 128.8 24.3%
10-20 181.7 34.3%
20-30 100.7 19.0%
30-40 49.7 9.4%
40-50 27 5.1%
50-60 20.1 3.8%
60-70 15.6 3.0%
70-80 5.8 1.1%
80-90 0 0.0%
Total 529.4 100%
Lumens Per Zone
Orb Optronix, Inc.
1003 7th
Ave
Kirkland, WA 98033 Device Ref #: P30LN-L540-C27-B25
tel: Date Issued:
fax: Date Tested:
Candela Plots
801 912 2645
425 605 8500 4/16/2011
3/17/2011
0
200
400
600
800
1000
1200
1400
1600
1800
2000
0 10 20 30 40 50 60 70 80
Lum
ino
us
inte
nsi
ty (
cd)
q (degrees)
Luminous Intensity Distribution (cd) vs Angle
0
22.5
45
67.5
90
112.5
135
157.5
180
202.5
225
Zone Lumens % Lamp
0-30 411.2 77.7%
0-40 460.9 87.1%
0-60 507.9 96.0%
60-90 21.4 4.0%
70-100 5.8 1.1%
90-120 0 0.0%
0-90 529.3 100%
90-180 0 0%
0-180 529.3 100%
Zonal Lumen Summary
Zone Lumens % Total
0-10 128.8 24.3%
10-20 181.7 34.3%
20-30 100.7 19.0%
30-40 49.7 9.4%
40-50 27 5.1%
50-60 20.1 3.8%
60-70 15.6 3.0%
70-80 5.8 1.1%
80-90 0 0.0%
Total 529.4 100%
Lumens Per Zone
Report Format ORB 2.0 S/G
REV: 1.0 Page 6 of 7Approved By: DWR .
INITIALS ONLY.
ORB OPTRONIX - TEST & MEASUREMENT LABORATORY - PRODUCT REPORTIES LM-79-08 Approved Method for the Electrical and Photometric Measurements of Solid-State Lighting Products
Zone Lumens % Lamp
0-30 411.2 77.7%
0-40 460.9 87.1%
0-60 507.9 96.0%
60-90 21.4 4.0%
70-100 5.8 1.1%
90-120 0 0.0%
0-90 529.3 100%
90-180 0 0%
0-180 529.3 100%
Zonal Lumen Summary
Zone Lumens % Total
0-10 128.8 24.3%
10-20 181.7 34.3%
20-30 100.7 19.0%
30-40 49.7 9.4%
40-50 27 5.1%
50-60 20.1 3.8%
60-70 15.6 3.0%
70-80 5.8 1.1%
80-90 0 0.0%
Total 529.4 100%
Lumens Per Zone
Orb Optronix, Inc.
1003 7th
Ave
Kirkland, WA 98033 Device Ref #: P30LN-L540-C27-B25
tel: Date Issued:
fax: Date Tested:
Luminance
Irradiance
3/17/2011
END OF REPORT
760401 91L122464
Serial #
2009064
0910A00133
Manufacturer Model
INSTRUMENTATION USED - Goniometric measurement
Description
ADDITIONAL NOTES
2/12/2011
-
1/5/2011
Orb Optronix SP-75
Regulated Power Supply Elgar CW801
Irradiance Calibration Source OL-200M S/N: 1036
Calibration Source Controller OL-83A S/N: 07220256
--
Spectrometer
Digital Power Meter
4/12/2011
-
1/5/2012Yokogawa
Standard luminance source: OL-455 of Optronic Laboratories Inc.
Luminance Calibration Source OL-455-5-1 S/N: 03101043
Calibration Source Controller OL-450 S/N: 03602509
2-Axis Type C Goniometer Orb Optronix MS-STA-GON-C-01
Standard irradiance source: OL-200M of Optronic Laboratories Inc.
Last Cal Next Cal
425 605 8500 4/16/2011
801 912 2645
*2 Data points corresponding to less than 10% of peak flux values are not displayed.
*1Unless specified otherwise, reported values are averages over all measurement angles weighted by the luminous flux. Testing
performed is in compliance with IESNA LM-79.
Zone Lumens % Lamp
0-30 411.2 77.7%
0-40 460.9 87.1%
0-60 507.9 96.0%
60-90 21.4 4.0%
70-100 5.8 1.1%
90-120 0 0.0%
0-90 529.3 100%
90-180 0 0%
0-180 529.3 100%
Zonal Lumen Summary
Zone Lumens % Total
0-10 128.8 24.3%
10-20 181.7 34.3%
20-30 100.7 19.0%
30-40 49.7 9.4%
40-50 27 5.1%
50-60 20.1 3.8%
60-70 15.6 3.0%
70-80 5.8 1.1%
80-90 0 0.0%
Total 529.4 100%
Lumens Per Zone
Report Format ORB 2.0 S/G
REV: 1.0 Page 7 of 7Approved By: DWR .